Edge-Core SAF51003I User Manual
The Edge-Core SAF51003I Network Appliance Platform is a compact and powerful server designed for a wide range of applications, including network security, SD-WAN, and edge computing. With its Intel Atom C3000 series processor, up to 32GB of DDR4 memory, and multiple storage options including M.2 SSDs and a 2.5" HDD, the SAF51003I delivers high performance and reliability. It also features a rich set of I/O ports, including 8x 1000BASE-T RJ-45 LAN ports, a dedicated 1000BASE-T RJ-45 WAN port, and a 1000BASE-T RJ-45 DMZ port, making it ideal for connecting to various network devices.
Reklama
Reklama
SAF51003I
Network Appliance Platform
U s e r M a n u a l
www.edge-core.com
User Manual
SAF51003I
Network Appliance Platform
E052018-CS-R01
How to Use This Guide
This guide includes detailed information on the Network Appliance Platform, including how to install components and maintain the system. To deploy this device effectively and ensure trouble-free operation, you should first read the relevant sections in this guide so that you are familiar with all the features.
Who Should Read this Guide?
This guide is for system technicians who are responsible for installing, maintaining, and troubleshooting this Network Security Platform. The guide assumes a basic working knowledge of server appliance hardware, LANs (Local Area Networks), and the Internet Protocol (IP).
How this Guide is
Organized
The organization of this guide is based on the device’s main components. An introduction and initial configuration information is also provided.
The guide includes these sections:
■ Section I “Getting Started” — Includes an introduction to the device’s hardware features.
■ Section II “Installation Procedures” — Includes how to install or replace device hardware components.
■ Section III “System Configuration” — Includes information on how to configure
BIOS settings.
■ Section IV “Appendices” — Includes information on troubleshooting device problems and safety and regulatory statements.
– 3 –
How to Use This Guide
Conventions
The following conventions are used throughout this guide to show information:
Note: Emphasizes important information or calls your attention to related features or instructions.
Caution:
Alerts you to a potential hazard that could cause loss of data, or damage the system or equipment.
Warning: Alerts you to a potential hazard that could cause personal injury.
Revision History
This section summarizes the changes in each revision of this guide.
May 2018 Revision
This is the first revision of this guide.
– 4 –
Contents
Section I
Section II
How to Use This Guide 3
Contents 5
Figures 8
Tables 9
Getting Started 10
1 System Overview 11
Introduction 12
Front Panel Features
Rear Panel Features
System Board Layout
System Block Diagram
System Specifications
12
12
13
14
15
2 System Components
Power Supply
System Memory
M.2 Solid-State Drives (SSDs)
Mini PCIe Slot
System Battery
16
17
17
18
18
19
Installation Procedures
3 Chassis Installation
General Installation Guidelines
Installation Precautions
Installing the Server Appliance on a Desktop
– 5 –
20
21
22
22
23
Contents
Section III
Section IV
Appliance Cooling Requirements
Removing the Top Cover
4 Server Connections
Grounding the Device
Connecting Power and Powering On
Connecting to the Console Port
Connecting to 1000BASE-T Network Ports
System Configuration 31
5 BIOS Setup Access
BIOS Introduction
Accessing the BIOS Setup Menu
BIOS Setup Utility Keyboard Commands
6 BIOS Settings
Main Menu
Advanced Menu
IntelRCSetup 39
Security menu 40
Administrator Password
User Password
40
40
BOOT Menu
Save and Exit Menu
41
42
36
37
38
32
33
33
34
23
24
25
26
27
27
29
Appendices 44
A Troubleshooting 45
Power Supply
POST and Boot Problems
45
45
Cooling and Fans
Network Connections
45
46
B Installing the Intel Driver 47
– 6 –
C LED Control Utility
D Safety and Regulatory Information
Contents
48
49
– 7 –
Figures
Figure 1: SAF51003I Front Panel Features
Figure 2: SAF51003I Rear Panel Features
Figure 3: System Board
Figure 4: System Block Diagram
Figure 5: AC/DC Power Adapter
Figure 6: DIMM Slot
Figure 7: M.2 SSD Slot on System Board
Figure 8: Mini PCIe Slot
Figure 9: System Battery
Figure 10: Installing the Appliance on a Desktop
Figure 11: Removing the Top Cover
Figure 12: Grounding the Device
Figure 13: Connecting Power to the Server
Figure 14: Connecting to the Console Port
Figure 15: Connecting to 1000BASE-T RJ-45 Ports
Figure 16: Access to BIOS Settings
Figure 17: BIOS Setup Menu Access
Figure 18: BIOS Main Menu
Figure 19: BIOS Main Menu
Figure 20: BIOS Advanced Menu
Figure 21: BIOS Intel RC Setup
Figure 22: BIOS Security Menu
Figure 23: BIOS Boot Menu
Figure 24: BIOS Save and Exit Menu
Figure 25: Status LEDs
Figure 26: LED Control Utility
– 8 –
38
39
41
41
33
34
34
37
42
48
48
26
27
28
30
18
19
23
24
14
17
17
18
12
12
13
Tables
Table 1: SAF51003I Specifications
Table 2: Console Cable Wiring
Table 3: Maximum Twisted-Pair Copper Cable Lengths
Table 4: RJ-45 Port Status LEDs
Table 5: BIOS Setup Utility Commands
15
28
29
30
34
– 9 –
Section I
Getting Started
This section provides an overview of the Network Appliance Platform and introduces some basic concepts.
This section includes these chapters:
■ “System Overview” on page 11
■ “System Components” on page 16
– 10 –
1
System Overview
This chapter includes the following sections:
■ “Introduction” on page 12
■ “Front Panel Features” on page 12
■ “Rear Panel Features” on page 12
■ “System Board Layout” on page 13
■ “System Block Diagram” on page 14
■ “System Specifications” on page 15
– 11 –
Chapter 1
| System Overview
Introduction
Introduction
The SAF51003I Network Appliance Platform is an open server appliance based on standard Intel® x86 communications hardware. The system includes internal eMMC and M.2 SSD disk drives, all contained within a desktop form-factor.
Front Panel Features
Figure 1: SAF51003I Front Panel Features
1 2 3 4 5
1.
Power Status LED
2.
Custom-defined Status LEDs
3.
WAN Port Status LEDs
Rear Panel Features
Figure 2: SAF51003I Rear Panel Features
1 2
4.
DMZ Port Status LED
5.
LAN Ports 1-8 Link Status LEDs
3 4
1.
1000BASE-T RJ-45 LAN Ports
2.
1000BASE-T RJ-45 WAN Port
3.
Grounding Point
4.
DC Power Jack
5 6 7 8
5.
1000BASE-T RJ-45 DMZ Port
6.
USB Port
7.
Console Port
8.
Reset Button
– 12 –
System Board Layout
Figure 3: System Board
1 2 3 4
Chapter 1
| System Overview
System Board Layout
5
6
7
8
14
1.
Fan power connectors
2.
DDR SODIMM slot
3.
CPU and heatsink
4.
System battery
5.
HDD/SSD power connector
6.
SATA III ports
7.
M.2 SSD card slot
13 12 11 10
8.
2.5” 500 GB HDD
9.
Reset button
10. Console port
11. USB slot
12. RJ-45 WAN and DMZ ports
13. RJ-45 LAN ports
14. DC power jack
9
– 13 –
Chapter 1
| System Overview
System Block Diagram
System Block Diagram
Figure 4: System Block Diagram
– 14 –
Chapter 1
| System Overview
System Specifications
System Specifications
Table 1: SAF51003I Specifications
Item
Form-Factor
Dimensions (W x D x H):
Weight
CPUs
Memory
Local Storage
I/O Interfaces
Network Interfaces
Expansion
Accelerator
OS Version
Power Adapter
System Cooling
Temperature
Humidity
Compliances
Specification
Compact desktop
300 x 200 x 38.5 mm (11.81 x 7.87 x 1.52 inches)
1.58 kg (3.48 lb)
SoC, Intel® Atom™ Processor for Communications C3000 Series
(FCBGA, 14nm), supports 2-4 cores, 2.2 GHz (turbo 2.4 GHz)
Sockets: 2 x 260pin DDR4 SODIMM slots
Type: DDR4 1866/2133/2400 MT/s (64GB max)
1 x M.2 SATAIII SSD, support 2242/2280 type
1 x 2.5” 500GB HDD
Optional on-board eMMC 16-256GB (not equipped by default)
1 x RJ-45 type serial console
1 x hardware reset button (through hole)
1 x RJ-45 GbE for DMZ
1 x RJ-45 GbE port for WAN
8 x RJ-45 GbE for LAN
Type: 1x Mini PCIe
Signal: PCIe x1 and USB 2.0
Advanced Technologies: Intel® VT-x, Intel® VT-d, SR-IOV, VMDq,
QuickAssist, PECI over SMBUS, eSPI, NC-SI, Core and Memory
RAPL, Memory OLTT and CLTT
Ubuntu 16.04 Server X64
Input: AC 110 to 240 @ 50/60 Hz
Output: 12 VDC, 5.0 A, 60 W
2x PWM fans, supporting smart-fan
Operating: 0 °C to 40°C (32 °F to 104 °F)
Storage: -20 °C to 70 °C (-4 °F to 158 °F)
Operating: 20% to 90% (non-condensing)
Storage: 5% to 90% (non-condensing)
CE
FCC
RoHS 2.0
– 15 –
2
System Components
This chapter includes the following sections:
■ “Power Supply” on page 17
■ “System Memory” on page 17
■ “M.2 Solid-State Drives (SSDs)” on page 18
■ “Mini PCIe Slot” on page 18
■ “System Battery” on page 19
– 16 –
Chapter 2
| System Components
Power Supply
Power Supply
The server system includes an external AC/DC power adapter. The power adapter connects to an AC power source in the range 110 to 240 VAC, 50/60 Hz.
Figure 5: AC/DC Power Adapter
1
2
1.
AC power cord socket 2.
DC power connector
System Memory
The server has one DIMM memory slot. The slot accepts a 260-pin DDR4
SODIMM. You can install up to a maximum of 32GB.
Figure 6: DIMM Slot
1
1.
DIMM slot
– 17 –
2
2.
Module release lever
Chapter 2
| System Components
M.2 Solid-State Drives (SSDs)
M.2 Solid-State Drives (SSDs)
The server supports a single SSD (32GB default) in compact M.2 form factor for local storage. The 2242/2280 type SSD card installs into the M.2 SATA III slot on the system board.
Figure 7: M.2 SSD Slot on System Board
1 2
3
1.
M.2 securing screw
3.
M.2 slot
2.
SSD 2280/22110 M.2 card
Mini PCIe Slot
The server supports one standard Mini PCIe slot for add-in cards. A second Mini
PCIe slot (CONN 6) is non-standard with added 5 VDC power on pin 17.
Figure 8: Mini PCIe Slot
1 2
1.
Standard Mini PCIe card slot
– 18 –
2.
Non-standard Mini PCIe card slot
Chapter 2
| System Components
System Battery
System Battery
The server system includes one lithium battery. If the system no longer displays the correct date and time, the system battery may need to be replaced.
Be sure to replace the battery with the same type, a CR2032 lithium battery.
Warning: Risk of fire if the battery is installed incorrectly.
Figure 9: System Battery
1
1.
System battery
– 19 –
Section II
Installation Procedures
This section provides details on installing server hardware.
This section includes these chapters:
■ “Chassis Installation” on page 21
■ “Server Connections” on page 25
– 20 –
3
Chassis Installation
This chapter includes the following sections:
■ “General Installation Guidelines” on page 22
■ “Installation Precautions” on page 22
■ “Installing the Server Appliance on a Desktop” on page 23
■ “Appliance Cooling Requirements” on page 23
■ “Removing the Top Cover” on page 24
– 21 –
Chapter 3
| Chassis Installation
General Installation Guidelines
General Installation Guidelines
Be sure to follow the guidelines below when choosing a location.
■ The installation location should:
■ be able to maintain its temperature within 0 to 45 °C (32 to 113 °F) and its humidity within 10% to 90%, non-condensing.
■ provide adequate space (approximately five centimeters or two inches) on all sides for proper air flow.
■ be accessible for installing, cabling and maintaining the device.
■ allow the status LEDs to be clearly visible.
■ Make sure twisted-pair cable is always routed away from power lines, fluorescent lighting fixtures and other sources of electrical interference, such as radios and transmitters.
■ Make sure that the unit is connected to a separate grounded power outlet and is powered from an independent circuit breaker. As with any equipment, using a filter or surge suppressor is recommended. Verify that the external power requirements for the switch can be met as listed under “Power Supply Units” on page 27 .
Installation Precautions
Warning: This appliance uses lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly at a transmit port when it is powered on.
Warning: When selecting a fiber QSFP+ device, considering safety, please make sure that it can function at a temperature that is not less than the recommended maximum operational temperature of the product. You must also use an approved
Laser Class 1 QSFP+ transceiver.
Caution: Before installing your appliance, first review all the safety statements and guidelines in the Safety and Regulatory Information document.
Caution: The earth connection must not be removed unless all supply connections have been disconnected.
– 22 –
Chapter 3
| Chassis Installation
Installing the Server Appliance on a Desktop
Installing the Server Appliance on a Desktop
The server appliance can be installed on a desktop or shelf.
To install the appliance on a desktop, follow these steps:
1.
Attach the four adhesive feet to the bottom of the device.
Figure 10: Installing the Appliance on a Desktop
1
1.
Adhesive feet.
2.
Set the device on a flat surface near an AC power source, making sure there are at least two inches of space on all sides for proper air flow.
Appliance Cooling Requirements
Wherever the appliance is located, be sure to pay close attention to the device’s cooling requirements. The location should be well ventilated and provide unrestricted air flow at the front, back, and sides of the appliance. If the air flow is insufficient, it may cause the appliance to overheat and possibly fail.
– 23 –
Chapter 3
| Chassis Installation
Removing the Top Cover
Removing the Top Cover
To access internal components of the appliance, the top cover must be removed.
Figure 11: Removing the Top Cover
3
1
1
2
2
1.
Side panel screws (2)
3.
Open direction
2.
Bottom panel screws (2)
1.
Unscrew the two side panel screws and two bottom panel screws.
2.
Push the cover towards the rear until it is free.
3.
Lift the cover off to remove it.
– 24 –
4
Server Connections
This chapter includes the following sections:
■ “Grounding the Device” on page 26
■ “Connecting Power and Powering On” on page 27
■ “Connecting to the Console Port” on page 27
■ “Connecting to 1000BASE-T Network Ports” on page 29
– 25 –
Chapter 4
| Server Connections
Grounding the Device
Grounding the Device
The rear panel of the server appliance includes a single-screw grounding terminal.
The surface area around this terminal is not painted in order to provide for a good connection. The terminal must be connected to ground to ensure proper operation and to meet electromagnetic interference (EMI) and safety requirements.
Figure 12: Grounding the Device
1
2
1.
Grounding terminal 2.
#14 AWG grounding wire
Before powering on the server, ground the device to earth as described below.
1.
Ensure the device is properly grounded in compliance with ETSI ETS 300 253.
Verify that there is a good electrical connection to the grounding point (no paint or isolating surface treatment).
2.
Disconnect all power cables to the device.
3.
Attach a #14 AWG stranded copper wire to the grounding terminal on the server.
4.
Then attach the grounding wire to the ground point.
Caution:
The earth connection must not be removed unless all supply connections have been disconnected.
– 26 –
Chapter 4
| Server Connections
Connecting Power and Powering On
Connecting Power and Powering On
The server needs to be powered from the included AC/DC power adapter. Before connecting the AC/DC power adapter to an AC power source, first verify that the external AC power source can provide 110 to 240 VAC, 50/60 Hz.
To connect the server to a power source:
1.
Connect the AC/DC power adapter to the DC power jack on the device.
Figure 13: Connecting Power to the Server
1
2
1.
DC power jack 2.
AC/DC power adapter connector
2.
Connect the AC/DC power adapter to an AC power source.
3.
Check the PWR LED indicator on the server to verify that power is being received. If not, recheck the power cord connections at the AC supply source and the AC/DC power adapter.
Connecting to the Console Port
The RJ-45 Console port on the server’s rear panel is used to connect to the server for BIOS configuration. The console device can be a PC or workstation running a
VT-100 terminal emulator, or a VT-100 terminal. An RJ-45 to DB-9 console cable can be used for connecting to a PC’s RS-232 serial DB-9 DTE (COM) port.
Note: To connect to notebooks or other PCs that do not have a DB-9 COM port, you can use a USB-to-male DB-9 adapter cable (not included with the server).
– 27 –
Chapter 4
| Server Connections
Connecting to the Console Port
Figure 14: Connecting to the Console Port
1
1.
Console port
The following table describes the pin assignments used in the console cable.
Table 2: Console Cable Wiring
Server’s RJ-45
Console Port
6 RXD (receive data)
Null Modem
3 TXD (transmit data)
<---------------------
--------------------->
4,5 SGND (signal ground) -----------------------
No other pins are used.
PC’s 9-Pin
DTE Port
3 TXD (transmit data)
2 RXD (receive data)
5 SGND (signal ground)
The serial port’s configuration requirements are as follows:
■ Default Baud rate—115200 bps
■ Character Size—8 Characters
■ Parity—None
■ Stop bit—One
■ Data bits—8
■ Flow control—none
Follow these steps to connect to the Console port:
1.
Attach one end of the included RJ-45-to-DB-9 serial cable to a DB-9 COM port connector on a management PC.
– 28 –
Chapter 4
| Server Connections
Connecting to 1000BASE-T Network Ports
2.
Attach the other end of the serial cable to the Console port on the server.
3.
Configure the PC’s COM port required settings using VT-100 terminal emulator software (such as HyperTerminal) running on the management PC.
4.
Press the Enter key on the management PC to access the BIOS.
If you boot the Ubuntu OS, log in using the default user account and password:
■ Account: edgecore
■ Password: 1111
■ Root Password: 1111
For a detailed description of BIOS configuration settings, see “BIOS Settings” on page 36 .
Connecting to 1000BASE-T Network Ports
The RJ-45 10/100/1000BASE-T network ports on the server support automatic
MDI/MDI-X pinout configuration, so you can use standard straight-through twistedpair cables to connect to any other network device. The connections require unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cables with RJ-45 connectors at both ends.
Table 3: Maximum Twisted-Pair Copper Cable Lengths
Cable Type
1000BASE-T
Category 5, 5e, or 6 100-ohm UTP or STP
100BASE-TX
Category 5 or better 100-ohm UTP or STP
10BASE-T
Category 3 or better 100-ohm UTP
Maximum Cable Length Connector
100 m (328 ft)
100 m (328 ft)
100 m (328 ft)
RJ-45
RJ-45
RJ-45
Follow these steps to connect network cable an RJ-45 port:
1.
Attach one end of a twisted-pair cable to the network device’s RJ-45 port.
– 29 –
Chapter 4
| Server Connections
Connecting to 1000BASE-T Network Ports
Figure 15: Connecting to 1000BASE-T RJ-45 Ports
1
1.
RJ-45 network port
2.
Attach the other end to an RJ-45 port on the server.
3.
As a connection is made, the status LEDs on the server port will turn on to indicate that the connection is valid.
Table 4: RJ-45 Port Status LEDs
LED Condition Status
Status (link/activity) On/Blinking Green The port has a valid 1 Gbps link. Blinking indicates traffic passing through the port.
On/Blinking Amber The port has a valid 10/100 Mbps link. Blinking indicates traffic passing through the port.
Off There is no valid link on the port.
– 30 –
Section III
System Configuration
This section provides a description of system software configuration.
This section includes these chapters:
■ “BIOS Setup Access” on page 32
■ “BIOS Settings” on page 36
– 31 –
5
BIOS Setup Access
This chapter includes the following sections:
■ “BIOS Introduction” on page 33
■ “Accessing the BIOS Setup Menu” on page 33
■ “BIOS Setup Utility Keyboard Commands” on page 34
– 32 –
Chapter 5
| BIOS Setup Access
BIOS Introduction
BIOS Introduction
The American Megatrends Inc. (AMI) BIOS software handles all basic communications between the CPUs and peripherals, as well as including code that supports advanced server system features. You can configure the BIOS settings through its menu-driven interface and then save the configuration into memory.
Note: You can access the system BIOS and configure settings with or without an operating system installed on the server.
This chapter describes how to access the BIOS setup menus and the following chapter, “BIOS Settings” on page 36 , describes the configuration settings.
Note that the majority of configuration settings are preconfigured as BIOS default values, whereas others are automatically detected during the boot-up process and configured without requiring any actions.
Accessing the BIOS Setup Menu
The server’s BIOS settings can be accessed through the console port.
1.
Connect a computer running VT-100 terminal emulator software to the console port following the procedure in the section “Connecting to the Console Port” on page 27 .
Figure 16: Access to BIOS Settings
1.
Console port
2.
Power-on the server.
1
– 33 –
Chapter 5
| BIOS Setup Access
BIOS Setup Utility Keyboard Commands
3.
When the BIOS boot message is displayed, press <Esc> on the keyboard to enter the BIOS setup menu.
Figure 17: BIOS Setup Menu Access
4.
The BIOS main menu displays and you can view settings and make configuration changes.
Figure 18: BIOS Main Menu
BIOS Setup Utility Keyboard Commands
The AMI BIOS setup utility uses only the connected computer keyboard for menu navigation and configuration settings. The commands for each menu are shown on the right side of each menu.
The basic commands are describe in Table 5 .
Table 5: BIOS Setup Utility Commands
Key
Right and Left arrows
Up and Down arrows
<Enter>
Action
Moves the cursor left or right (selects the menu).
Moves the cursor up or down (Selects the submenu or fields).
Selects the highlighted submenu.
– 34 –
Chapter 5
| BIOS Setup Access
BIOS Setup Utility Keyboard Commands
Table 5: BIOS Setup Utility Commands (Continued)
Key Action
+ (plus key)
- (minus key)
<F1>
<F2>
<F3>
<F4>
<Esc>
Scrolls forward through setting options of the highlighted field.
Scrolls backward through setting options of the highlighted field.
Displays help navigation.
Loads the previously used configuration.
Loads optimized default values.
Saves the configuration and exits the setup utility.
Exit the BIOS setup utility or the current submenu.
– 35 –
6
BIOS Settings
This chapter includes the following sections:
■ “Main Menu” on page 37
■ “Advanced Menu” on page 38
■ “IntelRCSetup” on page 39
■ “Security menu” on page 40
■ “BOOT Menu” on page 41
■ “Save and Exit Menu” on page 42
– 36 –
Main Menu
The main menu describes general system information.
Figure 19: BIOS Main Menu
Chapter 6
| BIOS Settings
Main Menu
This menu includes the following items:
■ BIOS Vendor — American Megatrends.
■ BIOS Version — The BIOS version.
■ Build Date and Time — Shows the BIOS build date and time.
■ Access Level — Displays the access rights of the current BIOS user.
■ Total Memory — Displays the total system memory.
■ System Language — Selects the display language for the BIOS.
■ System Date — Displays the RTC date. Use the [+] or [-] keys to set the date.
■ System Time — Displays the RTC time. Use the [+] or [-] keys to set the time.
– 37 –
Chapter 6
| BIOS Settings
Advanced Menu
Advanced Menu
The Advanced menu includes items for Trusted Computing and other system features.
Figure 20: BIOS Advanced Menu
This menu includes the following items:
■ Trusted Computing — Trusted Computing settings.
■ ACPI Settings — The Advanced Configuration and Power Interface (ACPI) settings. ACPI is the standard method for computers to discover and configure hardware components.
■ HW Monitor — Information on hardware health status.
■ Smart Fan Function — Configures system fan speeds and temperature threshold settings.
■ S5 RTC Wake Settings
— Enables the system to wake from an ACPI S5 (soft off) state based on a real-time clock alarm setting.
■ Serial Port Console Redirection — Settings that enable the BIOS settings to be configured from a serial port connection.
■ SIO Configuration
— Super I/O chip functions, such as serial port settings.
■ PCI Subsystem Settings
— Configures settings for PCI, PCI-X, and PCI.
– 38 –
Chapter 6
| BIOS Settings
IntelRCSetup
■ Network Stack Configuration — Enables the Unified Extensible Firmware
Interface (UEFI) network boot option.
■ CSM Configuration — Compatibility Support Module (CSM) configuration.
Settings for CSM provide support for legacy operating systems that are not UEFI compatible.
■ SDIO Configuration — Configures settings for access to SD storage devices.
■ USB Configuration — Configures settings for USB controllers and ports.
IntelRCSetup
The Intel RC Setup menu provides configuration access to Intel chipset features.
Figure 21: BIOS Intel RC Setup
This menu includes the following items:
■ Platform — The platform name of the Intel chipset.
■ RC Revision — The version of the Intel chipset.
■ Processor BSP Revision — The version of the Intel board support package.
■ Microcode Revision — The version of the Intel chip microcode.
■ Processor Configuration — Configures parameters related to the CPU.
■ CPU Thermal Configuration — Configures settings for CPU thermal control.
– 39 –
Chapter 6
| BIOS Settings
Security menu
■ CK420 Configuration — Enables spread spectrum support for the clock generator to reduce system EMI.
■ Miscellaneous Configuration — Settings for other Intel chipset parameters.
■ Wake on LAN Configuration — Enables network interface Wake on LAN function to power on the system.
■ North Bridge Chipset Configuration — Configures parameters for the processor memory, PCI bus connections, and AGP graphics functions.
■ South Bridge Chipset Configuration — Configures parameters for controlling system I/O functions.
Security menu
The Security menu allows you to set passwords to protect the system from unauthorized access.
Administrator
Password
The administrator password is limited to 3-20 characters and is case sensitive. The password does not support special characters, such as "!", "%", "^", "~".
When the administrator password is set, the password must be entered to access the BIOS setup menu. If an incorrect password is entered more than three times, the system BIOS displays a warning message.
User Password
The user password is limited to 3-20 characters and is case sensitive. The password does not support special characters, such as "!", "%", "^", "~".
When a user password is set, you must enter the password during system boot and to access the BIOS setup menu. If an incorrect password is entered more than three times, the system BIOS displays a warning message.
Note: To set a user password, you must first set an administrator password. Setting a user password first automatically sets the administrator password by default.
Note: If you forget the administrator password, the BIOS settings must be cleared by removing the system battery.
– 40 –
Figure 22: BIOS Security Menu
Chapter 6
| BIOS Settings
BOOT Menu
BOOT Menu
The Boot menu allows you to set the boot device priority sequence and various other parameters.
Figure 23: BIOS Boot Menu
– 41 –
Chapter 6
| BIOS Settings
Save and Exit Menu
This menu includes the following items:
■ Setup Prompt Timeout — The number of seconds to wait for the keystroke to enter the BIOS setup menu. (Range: 1-65535 seconds)
■ Bootup NumLock State — Sets the keyboard Numlock state.
■ Quiet Boot — Sets the screen display during boot-up. When set to disabled, the system displays POST messages. When set to enabled, the system logo is displayed.
■ Boot Option Priorities — Sets the priority sequence for boot device types. The selection for Boot Option #1 is the first priority.
■ Hard Drive BBS Priorities — Sets the boot priority sequence for installed hard drive devices.
Save and Exit Menu
The Save and Exit menu provides options for saving BIOS settings and exiting the setup utility.
Figure 24: BIOS Save and Exit Menu
This menu includes the following items:
■ Save Changes and Exit — Saves the current settings and exits the BIOS setup utility. Select the field and press Enter. In the dialog box that displays, select
“Yes” to save the settings and exit the BIOS setup utility.
– 42 –
Chapter 6
| BIOS Settings
Save and Exit Menu
■ Discard Changes and Exit — Discards the current changes, and exits the
BIOS setup utility.
■ Save Changes and Reset — Saves the current changes and reboots the server.
■ Discard Changes and Reset — Discards the current changes and reboots the server.
■ Save Changes — Saves the current BIOS settings.
■ Discard Changes — Discards the current changes.
■ Restore Defaults — Restores the BIOS configuration to factory default values.
■ Save as User Defaults — Saves the current BIOS configuration as a User
Default.
■ Restore User Defaults — Restores the BIOS configuration to previously saved
User Default values.
■ Boot Override — Allows you to select an available boot option that overrides other boot priorities when you exit the BIOS setup utility and reboot the system.
– 43 –
Section IV
Appendices
This section provides additional information and includes these items:
■ “Troubleshooting” on page 45
■ “Installing the Intel Driver” on page 47
■ “LED Control Utility” on page 48
■ “Safety and Regulatory Information” on page 49
– 44 –
A
Troubleshooting
When possible, before checking specific troubleshooting options, always look for
POST messages by first rebooting the server using one of these methods:
■ Reset the system through OS software.
■ Power down by removing power to the unit.
Power Supply
If the server does not power on, check these items:
■ Make sure power is available at the source outlet.
■ Look for loose power cord connections.
Note: If you cannot isolate the power problem, the power adapter may be defective. Replace the power adapter and check all items again.
POST and Boot Problems
If the server does not complete the POST or boot the OS, check these items:
■ Check the POST messages for errors.
■ Check installed SSD cards are properly seated.
■ Check the boot settings in the BIOS.
■ OS software is not installed or corrupted. Reinstall the OS.
Cooling and Fans
If the system is running hot, check these items:
■ Make sure the top cover is installed.
– 45 –
Appendix A
| Troubleshooting
Network Connections
■ Check to be sure the ambient temperature is not too high.
■ Make sure all fans are running properly.
■ Check the fan settings in the BIOS. The fans might need to run at a higher speed.
■ Make sure that airflow around the server is not obstructed.
Network Connections
If there are problems with network connections, check these items:
■ Verify that the server and attached device are powered on.
■ Be sure the cable is plugged into both the server port and corresponding device.
■ Verify that the proper cable type is used and its length does not exceed specified limits.
■ Check the attached device and cable connections for possible defects. Replace the defective cable if necessary.
– 46 –
B
Installing the Intel Driver
If after installing the Linux OS some RJ-45 ports cannot be found, download and install the latest Intel ixgbe driver for your OS.
For example, you install Ubuntu 16.04.4 and find that ports LAN1–LAN8 can be used by the built-in Intel igb driver, but the WAN and DMZ ports cannot be found in the OS. In this case, download and install the latest Intel ixgbe driver.
The Intel ixgbe driver and related information can be found at the following URL: https://downloadcenter.intel.com/download/14687/Intel-Network-Adapter-Driverfor-PCIe-Intel-10-Gigabit-Ethernet-Network-Connections-Under-Linux-
– 47 –
C
LED Control Utility
The custom-defined Status LEDs can be controlled using a software utility. If you do not have the Utility file, contact Edgecore sales or technical support.
Figure 25: Status LEDs
1
1.
Status 1 and Status 2 LEDs
1.
Make sure you have the Utility file, which includes two files; devmen2.c
and test_led.py
.
2.
At the Linux command line, type gcc -o devmem2 devmem2.c
to compile.
3.
Execute test_led.py
to see detailed information and how to use the utility.
Figure 26: LED Control Utility
– 48 –
D
Safety and Regulatory
Information
FCC Class A
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.
You may use unshielded twisted-pair (UTP) for RJ-45 connections - Category 3 or better for 10 Mbps connections, Category 5 or better for 100 Mbps connections,
Category 5, 5e, or 6 for 1000 Mbps connections. For fiber optic connections, you may use 50/125 or 62.5/125 micron multimode fiber or 9/125 micron singlemode fiber.
Japan - VCCI Class A
この装置は , クラス A 情報技術装置です。この装置を家庭環境で使用す
ると電波妨害を引き起こすことがあります。この場合には使用者が適切な
対策を講ずるよう要求されることがあります。 VCCI-A
CE Mark
CE Mark Declaration of Conformance for EMI and Safety (EEC)
This information technology equipment complies with the requirements of the
Council Directive 2014/30/EU on the Approximation of the laws of the Member
States relating to Electromagnetic Compatibility and 2014/35/EU for electrical equipment used within certain voltage limits. For the evaluation of the compliance with these Directives, the following standards were applied:
RFI Emission: ■ Limit according to 55032:2012+AC:2013, Class A
■ Limit for harmonic current emission according to EN 61000-
3-2:2014, Class A
■ Limitation of voltage fluctuation and flicker in low-voltage supply system according to EN 61000-3-3:2013
Immunity: ■ Product family standard according to EN 55024:2010+
A1:2015
– 49 –
Appendix D
| Safety and Regulatory Information
LVD:
■
■
■
■
■
■
■
■
Electrostatic Discharge according to IEC 61000-4-2:2008
ED. 2.0
Radio-frequency electromagnetic field according to
IEC 61000-4-3:2010 ED. 3.2
Electrical fast transient/burst according to IEC 61000-4-
4:2012 ED. 3.0
Surge immunity test according to IEC 61000-4-5:2014 ED.
3.0
Immunity to conducted disturbances, Induced by radiofrequency fields: IEC 61000-4-6:2013 ED. 4.0
Power frequency magnetic field immunity test according to
IEC 61000-4-8:2009 ED. 2.0
Voltage dips, short interruptions and voltage variations immunity test according to IEC 61000-4-11:2004 ED. 2.0
EN 60950-
1:2006+A11:2009+A1:2010+A12:2011+A2:2013
PSE Alarm
本製品に同梱いたしております電源コードセットは、
本製品専用です。本電源コードセットは、本製品以外の
製品並びに他の用途でご使用いただくことは出来ません。
製品本体に同梱された電源コードセットを利用し、他製品
の電源コードセットを使用しないで下さい。
Power Cord Safety
Please read the following safety information carefully before installing the switch:
Warning: Installation and removal of the unit must be carried out by qualified personnel only.
■ The unit must be connected to an earthed (grounded) outlet to comply with international safety standards.
■ Do not connect the unit to an A.C. outlet (power supply) without an earth
(ground) connection.
■ The appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an EN 60320/IEC 320 appliance inlet.
■ The socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting the power cord from the outlet.
– 50 –
Appendix D
| Safety and Regulatory Information
■ This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 60950. The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT† supplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to earth
(ground).
† Impédance à la terre
Important! Before making connections, make sure you have the correct cord set.
Check it (read the label on the cable) against the following:
Power Cord Set
U.S.A. and Canada
Denmark
Switzerland
U.K.
Europe
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least 10 A
The attachment plug must be an earth-grounding type with NEMA 5-15P
(15 A, 125 V) configuration.
The supply plug must comply with Section 107-2-D1, Standard DK2-1a or
DK2-5a.
The supply plug must comply with SEV/ASE 1011.
The supply plug must comply with BS1363 (3-pin 13 A) and be fitted with a 5 A fuse which complies with BS1362.
The mains cord must comply with IEC 60227 (designation
60227 IEC 52).
The supply plug must comply with CEE7/7 (“SCHUKO”).
The mains cord must comply with IEC 60227 (designation
60227 IEC 52).
IEC-320 receptacle.
Veuillez lire à fond l'information de la sécurité suivante avant d'installer le Switch:
Avertissement: L’installation et la dépose de ce groupe doivent être confiés à un personnel qualifié.
■ Ne branchez pas votre appareil sur une prise secteur (alimentation électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).
■ Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la masse) afin de respecter les normes internationales de sécurité.
– 51 –
Appendix D
| Safety and Regulatory Information
■ Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale) doit respecter une configuration qui permet un branchement sur une entrée d’appareil EN 60320/IEC 320.
■ La prise secteur doit se trouver à proximité de l’appareil et son accès doit être facile. Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant son cordon électrique au niveau de cette prise.
■ L’appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme IEC 60950. Ces conditions ne sont maintenues que si l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.
France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos alimentations sont du type impédance à la terre, ce groupe doit être alimenté par une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport 1:1, avec un point secondaire de connexion portant l’appellation Neutre et avec raccordement direct à la terre (masse).
Cordon électrique - Il doit être agréé dans le pays d’utilisation
Etats-Unis et Canada: Le cordon doit avoir reçu l’homologation des UL et un certificat de la
CSA.
Les spécifications minimales pour un cable flexible sont AWG No. 18, ouAWG No. 16 pour un cable de longueur inférieure à 2 mètres.
- type SV ou SJ
- 3 conducteurs
Danemark:
Suisse:
Europe
Le cordon doit être en mesure d’acheminer un courant nominal d’au moins 10 A.
La prise femelle de branchement doit être du type à mise à la terre (mise
à la masse) et respecter la configuration NEMA 5-15P (15 A, 125 V).
La prise mâle d’alimentation doit respecter la section 107-2 D1 de la norme DK2 1a ou DK2 5a.
La prise mâle d’alimentation doit respecter la norme SEV/ASE 1011.
La prise secteur doit être conforme aux normes CEE 7/7 (“SCHUKO”)
Le cordon d'alimentation doit être conforme à la norme IEC 60227 (IEC
60227 désignation 52)
Bitte unbedingt vor dem Einbauen des Switches die folgenden
Sicherheitsanweisungen durchlesen:
Warnung: Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen.
■ Das Gerät sollte nicht an eine ungeerdete Wechselstromsteckdose angeschlossen werden.
– 52 –
Appendix D
| Safety and Regulatory Information
■ Das Gerät muß an eine geerdete Steckdose angeschlossen werden, welche die internationalen Sicherheitsnormen erfüllt.
■ Der Gerätestecker (der Anschluß an das Gerät, nicht der
Wandsteckdosenstecker) muß einen gemäß EN 60320/IEC 320 konfigurierten
Geräteeingang haben.
■ Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die
Stromversorgung des Geräts kann nur durch Herausziehen des
Gerätenetzkabels aus der Netzsteckdose unterbrochen werden.
■ Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen
(Sicherheitskleinstspannung) gemäß IEC 60950. Diese Bedingungen sind nur gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter SELV-
Bedingungen betrieben werden.
Stromkabel . Dies muss von dem Land, in dem es benutzt wird geprüft werden:
Schweiz Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen einhalten.
Europe Das Netzkabel muss mit IEC 60227 (IEC 60227 entsprechen Bezeichnung 52)
Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).
– 53 –
SAF51003I
E052018-CS-R01