HySecurity SlideSmart DC 15 Installation And Reference Manual
जाहिरात
जाहिरात
Installation and Reference Manual
SlideSmart DC
™
SlideSmart DC
15
, SlideSmart DC
10
F
SlideSmart DCS
15
, SlideSmart DCS
10
F (solar)
Pad-mounted electromechanical slide gate operator with Smart DC Controller
800-321-9947 • www.hysecurity.com
SlideSmart DC 15 Gate Operator
SlideSmart DCS 15 Gate Operator
SlideSmart DC 10F Gate Operator
SlideSmart DCS 10F Gate Operator
Installation and Maintenance Manual
D0337 - Revision D
(22 June 2012)
HySecurity
Corporate Headquarters
6623 S 228th Street
Kent, WA 98032
SlideSmart Components
S
LIDE
S
MART
C
OMPONENTS
Cover, Latch
Cover
Protection plate &
Cover
Pulley, Gearbox
Belt Drive, 2ft/s
Pulley, Gearbox
Belt drive, 1ft/s
Gearbox
Transformer
Battery kit, 8Ah
Sprocket
WARNING Label
Pulley, Motor
Brush kit
Buzzer
Switch, Reset
Emergency
Stop button
Motor
DC Switch,
On/Off
115VAC
Service
Outlet
Circuit
Breaker
O
AC
POW
OF
115VAC, 15A t
O
DC
POW
OF
Idler, 2x
AC Switch,
On/Off
Serial # location
Target sensor (2x)
Base plate
30 ft of #40 chain, bracket & hardware
Note: Refer to
Parts & Limited Warranty for SlideSmart parts list.
Revision D
Control Box
Board, Smart
DC Controller
Intro-1
Contents
SlideSmart Components
Introducing SlideSmart DC
Safety Requirements
Chapter 1: Installation
Chapter 2: Power
Revision D Contents 1
2
Contents
Chapter 3: Display and Menu Options
Chapter 4: Smart DC Controller
SlideSmart DC Installation and Reference Manual Revision D
Contents
Chapter 5: Bi-parting Gate Systems
Chapter 6: Reference
.................................................................................. 6-1
.............................................................................................. 6-6
Appendix A: Installation Configurations
Parts & Limited Warranty
L IMITED W ARRANTY ...................................................................................................................................... G-3
Revision D Contents 3
Contents
4 SlideSmart DC Installation and Reference Manual Revision D
Intelligent Features: Smart DC ControllerTM
Introducing SlideSmart DC
Thank you for purchasing our premium SlideSmart DC™ slide gate operator. At HySecurity® Gate, Inc., we pride ourselves on quality. Our new line of electromechanical gate operators include a number of unparalleled user benefits:
Robust - An especially low flex, corrosion resistant, steel chassis combines with an attractive, key-locked, fade resistant, roto-molded cover. The components on the Smart DC Controller™ are protected by opto-isolators which shield them from power surges and lightning strikes.
Power - The Smart DC Controller provides variable speed control to a powerful, continuous duty 24V DC motor which drives the gearbox. The electronics, motor and gear box are rated to operate in temperatures that range from -13°F to 158°F (-25°C to 70°C). SlideSmart DC 15 is rated for gates up to 40 feet long and 1,500 pounds (12m and 682kg). SlideSmart DC 10F is rate for gates up to 40ft and 1,000lbs. (12m and 454kg).
Solar options are available for both models.
Finesse - A variable rate of gate acceleration and deceleration, dependent upon gate weight and length, assures very smooth handling.
UPS backup and Solar ready - Two 12V, 8 amp hour (Ah) batteries will provide a fully functional gate operator
(up to 4000ft/1219m of gate travel) when AC power is unavailable. Four user-selectable UPS modes are available. 12VDC and 24VDC are available to power accessory controls. An optional base extension is available that provides space for the optional 50Ah batteries which support solar applications or usage during extended power outages.
I
NTELLIGENT
F
EATURES
: S
MART
DC C
ONTROLLER
TM
Menus and User relays - The Smart DC Controller has 46 menu items to allow installer configuration of gate function and two user relays, which can be configured for 22 different functions.
Independent adjustment for open and close gate speeds - An easy-to-use menu on the Smart DC Controller allows the installer to vary the open and close speed settings.
Intelligent Inherent Entrapment Sensor (IES) - Any impediment to gate travel is sensed by the system, stopping gate movement per UL 325 Safety Standards. The intelligent system monitors gate power then adapts the IES to trip at an adjustable threshold above normal power.
Improved Liquid Crystal Display (LCD) - A 32-character LCD provides increased readability for programming and troubleshooting.
USB communications port - A direct connect provides accessibility to download system diagnostics and upload system configurations using the Smart Touch Analyze and Retrieve Tool (START) software.
START software and diagnostics - With START software loaded on a laptop computer, you can get the latest software upgrade and have an invaluable troubleshooting tool for all HySecurity operators. To download this free software, visit the HySecurity website at www.hysecurity.com.
Revision D Introducing SlideSmart DC Intro-3
Technical Support
T
ECHNICAL
S
UPPORT
For technical support, call your installer or authorized HySecurity distributor. Obtain the serial number of your operator before calling. Refer to
on the front page. For the name of a distributor near you, call HySecurity at 800-321-9947.
For information about HySecurity training for installers, maintenance personnel and end users, refer to the company website at www.hysecurity.com
or call 800-321-9947.
Intro-4 SlideSmart DC Installation and Reference Manual Revision D
Installer's Check List
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
I
NSTALLER
'
S
C
HECK
L
IST
The following list provides a high level overview of the tasks involved in installing the SlideSmart DC gate operator. Take a moment to review the list and check off the items as you complete the install.
Site Prep - concrete pad location/dimensions, distance from gate, chain height, and mounting considerations: post or base extension, front or rear installation.
Make sure gate installation complies with ASTM F2200 Standard Specification for Automated Vehicular
Gate Construction. And, install the supplied WARNING sign on both sides of the gate.
Check for compliance with local codes, site conditions, and NEC standards.
Install operator - (on concrete pad use four ½ - 13 x 3.5in long concrete wedge anchors.)
Attach chain end bracket to gate at proper height.
Attach chain to end brackets and feed under SlideSmart idlers and over chain sprocket.
Tighten chain using tensioning bolts.
Verify chain is level with idlers and parallel to operator and gate.
Connect red wire to DC Power Switch.
Turn DC Power ON.
Complete Initial Setup Menu programming.
Install the target magnet and make sure it is in line with and passes by the target sensor so it can be recognized by the software programming.
Connect AC Power.
Connect all accessory devices.
Set the Close Timer (through the User Menu).
Set gate speed, if applicable (through Installer Menu). Refer to START (
Smart Touch Analyze and Retrieve
section.
Set IES sensitivity, if needed (through Installer Menu).
Check the Smart DC Controller software version. If needed, upload the latest version from www.hysecurity.com. See
Smart Touch Analyze and Retrieve Tool .
Program changes through the Installer Menu depending on the accessory devices that you have installed.
Give a copy of the operator instructions to the end user. Show the end user how to:
• Remove the operator cover. Turn the power off and on to demonstrate learn limits after DC/AC cycles.
• Turn the DC power switch off, which disengages the motor, and manually push the gate.
• Test the red Emergency Stop Button located on the side of the control box. It can be accessed through a hole in the cover. See illustration on page S-8.
Take photographs of the completed installation site and save it in your business files.
Revision D Introducing SlideSmart DC Intro-5
Installer's Check List
Intro-6 SlideSmart DC Installation and Reference Manual Revision D
Important Safety Instructions
Safety Requirements
Automatic gate operators provide user convenience and security. However, because these machines can produce high levels of force, it is imperative that gate operator system designers, installers and end users be aware of potential hazards associated with improperly designed, installed, or maintained systems. The gate operator is only one component of the total gate operating system. It is the joint responsibility of the architect, site designer, purchaser, installer and end user to verify that the total system is appropriately configured for its intended use. Additionally, certain municipalities have established licensing, codes or regulations that regulate automated gate system design and installation. Consult local government agencies for up-to-date rules and regulations prior to gate system design or installation.
I
MPORTANT
S
AFETY
I
NSTRUCTIONS
!
WARNING
A moving gate can cause serious injury or death. Start the gate operator only when the gate’s travel path is clear.
Hazards, associated with automatic gates, can be reduced with proper site design, installation, and use.
manual and review all the literature that accompanies the product. It is important that only qualified installers handle the installation of the SlideSmart gate operator. A “qualified” installer has one of the following:
• A minimum of three years experience installing similar equipment.
• Proof of attending a HySecurity Technical Training seminar within the past three years.
• Significant manufacturer endorsements of technical aptitude in gate operator installation and operation.
Underwriter Laboratories (UL) and the American Society for Testing and Materials (ASTM) are responsible for current safety standards and regulations regarding gate operators and automated gates. All aspects of gate installation must comply with the appropriate safety standard. For the most up-to-date ASTM F2200 Gate and
Fence Standards, refer to www.astm.org
. For UL 325 Safety Standard, refer to www.ul.com.
Safety Standards - Installer's Responsibility
• Study the entire contents of this manual prior to installing, operating, or maintaining the SlideSmart gate operator. Taking extra time to align the gate operator and verify a fully functional installation will reduce maintenance, guarantee longest system life, and ensure customer satisfaction.
• Verify the gate operator usage class for the site. Refer to
Identifying Gate Operator Category and Usage Class
in this manual. Install SlideSmart only when the gate operator class is correct for the site and type of gate.
• Install an automatic operator only on gates that comply with ASTM F2200 Gate and Fence Standards.
Screen or enclose openings in the gate per UL 325 Safety Standards.
→
All horizontal slide gates must guard or screen openings from the gate’s base support to a minimum height of 6 feet (183cm) above the ground. The screen mesh must prevent a sphere of 2¼-inches
(57mm) in diameter from passing through an opening in the gate or the adjacent fence that is covered in the gate’s open position.
Revision D Safety Requirements S-1
Important Safety Instructions
→
Physical stops exist in the gate construction to prevent over-travel in both directions and guard posts prevent the gate from falling in the event of a roller failure.
• Before attaching the operator to the gate, slide the gate in both directions. Make sure it is level and moves freely. A gate that slides easily reduces strain on operator components. Gravity should play no part in the opening or closing of the gate.
• In the case of hydraulic operators, never over-tighten a clutch or pressure relief valve to compensate for a stiff or damaged gate.
• Make sure all exposed pinch points, rollers and wheels are guarded.
• To reduce the risk of entrapment throughout the entire travel path, make sure the gate is installed in a location so enough clearance is supplied between the gate and adjacent structures when opening or closing.
Minimize the parallel gap between the gate and the fence.
• Make sure a separate walk-through entrance is nearby. Make certain a clear pedestrian path is designated and signs direct pedestrians to the walk-through gate. The automated gate entry is for vehicle use only. No one should cross the path of a moving gate.
• Install the gate operator on the secure (non-public) side of the gate. Locate controls (Open, Close, Stop/
Reset) where a user will have a clear view of the gate.
• Mount access control devices beyond reach of the gate. The control devices that operate the gate must be:
• Located in a clear line of sight to the gate.
• Mounted beyond 6 feet (183cm) of the gate, to prevent users from touching or accessing the gate while operating the controls. People attempting to access the controls by reaching through or around the gate can be seriously injured or killed by the moving gate.
• Incorporate a security feature to prevent unauthorized use.
• The gate operator must be properly grounded and the incoming power voltage must match the voltage label on the junction box.
• Install enough external entrapment protection sensors so that pedestrians are protected from entrapment in both directions of the gate travel and all hazard areas and possible pinch points are fully protected. Review
the information found in Secondary Entrapment Protection Sensors
.
• Install the supplied WARNING signs on the inside and outside of the gate so they are clearly visible from both sides of the gate. Installing the signs is a requirement for UL 325 compliance.
• Connect radio and other remote access (non-resetting controls) to the RADIO OPTIONS terminals.
• Open and close the gate to confirm that it was properly installed and to ensure reduced risk of entrapment.
Verify the clearance between the gate and adjacent structures per UL 325 Safety Standards. Have a qualified gate technician test the gate monthly.
• When you complete the installation, show the end user how to:
→
Remove the cover. Turn the power off and on to demonstrate relearn limits after DC/AC cycles.
→
Turn the DC power switch off, which disengages the motor, and manually push the gate.
→
Use the Emergency Stop Button located on the side of the control box. It can be accessed through a hole in the cover.
NOTE
Gate operator instructions must be given to the owner per UL 325 Safety Standards.
S-2 SlideSmart DC Installation and Reference Manual Revision D
Important Safety Instructions
Safety Standards - Owner/User Responsibility
!
WARNING
A moving gate can cause serious injury or death. Automatic gate operators move gates with high force. Make sure gates and gate operators are installed to reduce the risks of entrapment. Verify your gate and gate operator comply with UL 325 Safety Standards and ASTM F2200 Gate and
Fence Standards. Ask for a copy of the gate operator’s product literature and review it. You are responsible for educating all gate system users about proper use of the automated gate system.
• Automatic gates are for vehicular use only; provide and maintain walkways and signs to direct pedestrians to a separate walk-through entrance.
• An automatic gate can start at any time without warning; always keep people away from the gate area.
• Never let children operate or play with gate controls. Keep all remote controls, especially radio transmitters, away from children. Do not allow children to play on or around the gate, gate area, or gate operators.
• Learn how to turn the power on and off. Learn how to manually release the gate.
CAUTION
Before attempting a manual release, make sure the gate is not moving.
• WARNING signs supplied with the gate operator must remain installed and clearly visible on both sides of the gate. The signs are required to maintain UL 325 compliance.
• Do not physically disable the warning buzzer and NEVER disconnect or cut its wires. The buzzer is required to function in the event of entrapment, regardless of UL 325 gate usage class. It provides an alert that the gate is about to move. Disabling the warning buzzer may increase the risk or extent of injury if entrapment occurs.
• Test the gate operator monthly. Specifically, test the primary Inherent Entrapment Sensor (IES) and secondary entrapment protection sensors. The gate must reverse its direction of travel upon contact with a rigid object and/or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and test the gate operator on a regularly maintained schedule can increase the risk of injury or death.
• Have a professional gate installer routinely test the entire gate operator and entrapment protection sensors.
Have a qualified service person make repairs to gate hardware to keep the gate running smoothly.
Revision D Safety Requirements S-3
Important Safety Instructions
Hazardous Materials and Proper Disposal
SlideSmart uses sealed, state-of-the-art Absorbed Glass Mat (AGM) batteries and highly recommends replacing used batteries with new AGM-type batteries.
!
CAUTION
The batteries used with the SlideSmart gate operator contain materials that are considered hazardous to the environment. Proper disposal of the battery is required by federal law. Refer to federal guidelines found in Hazardous Waste Regulations .
To reduce the risk of fire or injury to persons:
• Observe the polarity between the batteries and charging circuit.
• Never mix battery sizes, types, or brands. The charging circuit on HySecurity DC operators is designed for
AGM-type batteries, not lead acid-type batteries. HySecurity strongly recommends that only sealed AGM style batteries be used.
• Exercise care in handling batteries. Be aware that the metal found in rings, bracelets, and keys can conduct electricity, short the batteries, and cause potential injury.
• Do not open or mutilate the batteries. Battery cells contain corrosive materials which may cause burns and other injuries. The material within batteries is toxic.
• Always dispose of batteries properly. Do NOT place batteries in fire. The battery cells may explode. Follow federal guidelines for proper disposal of hazardous waste.
•
Replace batteries according to the instructions found in DC Battery Replacement.
S-4 SlideSmart DC Installation and Reference Manual Revision D
Secondary Entrapment Protection Sensors
S
ECONDARY
E
NTRAPMENT
P
ROTECTION
S
ENSORS
SlideSmart is equipped with a primary, Type A, inherent entrapment sensor (IES). UL 325 Safety Standard compliance requires installation of secondary entrapment protection sensors, the number of which, depends on the entrapment hazards that exist at each particular installation.
To comply with UL 325, the following external sensors may be used:
• Contact sensors, such as edge sensors
• Non-contact sensors, such as photoelectric eyes
The site designer or installer can choose either photoelectric eyes or edge sensors or use these devices in combination. Whatever devices are used, protection in both the opening and closing directions of gate travel must be provided.
The UL 325 Safety Standard for automatic sliding gates specifically requires that edge sensors or photoelectric eyes or a combination of both devices be installed to protect against pedestrian entrapment in BOTH directions of the gate travel and where an entrapment hazard exists.
PHOTOELECTRIC EYES: One or more photoelectric eyes shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate.
!
CAUTION
A photoelectric eye or contact sensor is also required to protect against possible entrapment if the gate opens to a position less than 16 inches from any object, such as a post or wall.
EDGE SENSORS: One or more edge sensors shall be located on the leading and trailing edges of a slide gate where the risk of entrapment or obstruction exists. One or more contact sensors (edge sensors) shall be located at the leading edge, trailing edge, and post-mounted, both inside and outside of a sliding gate.
SENSOR SECURITY: A hard-wired sensor shall be located and its wiring arranged so that communication between the sensor and gate is not subjected to mechanical damage.
SENSOR FUNCTION and COMMUNICATION: A sensor that transmits its signal to the gate operator must be located so its signal is not impeded by building structures or other obstructions. All sensors must be installed so that they function as intended for the end-use conditions.
UL 325 LISTING: The edge sensors and photo electric eyes must be tested and labeled as “Recognized
Components” under UL 325 in order to be deemed acceptable for use in a gate operator. Study the
and consider your specific installation to determine where the greatest entrapment risks exist.
Locate edge sensors and/or photoelectric sensors accordingly. Be certain that a sufficient number of sensors are used so that pedestrians are protected from entrapment in both directions of the gate travel and all hazard areas are fully protected. Refer to the UL website at www.ul.com
for the most up-to-date list of gate operator safety standards (UL 325). Refer to www.astm.org
for a complete list of ASTM F2200 Gate and Fence Standards.
Revision D Safety Requirements S-5
Secondary Entrapment Protection Sensors
Identifying Gate Operator Category and Usage Class
The SlideSmart operator, according to UL 325 Safety Standards, falls in the Slide Gate and Vertical Barrier
Arm category for gate operators. Its usage class is determined by the area that the vehicular gate services.
Four different vehicular usage classes are defined by UL 325:
Class I
Class I: Intended for use in a location of one to four single family dwellings or a parking area associated with one to four single family dwellings.
Class II
Class II: Intended for use in a commercial location or building such as a multifamily housing units (five or more single family units) hotels, garages, retail stores or other buildings servicing the general public.
Class III
Class III: Intended for use in an industrial location or building such as factories or loading docks or other locations not intended to service the general public.
Class IV
Class IV: Intended for use in guarded industrial locations or buildings such as an airport security area or other restricted access location, not servicing the general public, in which access is monitored by security personnel or via closed circuitry.
S-6 SlideSmart DC Installation and Reference Manual Revision D
Secondary Entrapment Protection Sensors
Choosing Secondary Entrapment Protection
The site designer or installer must determine which secondary entrapment sensor devices will be installed with the SlideSmart operator to meet UL compliance. The type of entrapment sensor device systems are described below. For a complete listing of the requirements, see UL 325 Safety Standards.
NOTE
SlideSmart is equipped with a primary, Type A, inherent entrapment sensor (IES) that complies with UL 325. Any impediment to gate travel causes the gate to stop and reverse.
Usage Class
Class I, II, III
Class IV
Primary Type Device
A
A
Secondary Type Device
B1, B2, C, or D
B1, B2, C, D, or E
To comply with UL 325, refer to the chart and take the following steps:
1) Select the Usage Class according to the gate’s locale and purpose.
2) The required UL 325 primary Type A sensor is an integral part of the SlideSmart system.
3) Based on the gate’s usage class, choose Secondary Type Devices: B1, B2, C, D, or E.
• To comply using B1 - install non-contact sensors (photoelectric sensor or the equivalent).
• To comply using B2 - install contact sensors (edge sensor device or the equivalent).
• To comply using a Type D device requires a CONSTANT HOLD push-button station. This CONSTANT
HOLD push-button station must be the only device that opens and closes the gate. It can only be used where the gate and push button station will be monitored by personnel 24 hours a day in full view of the gate area.
An automatic closing device (such as a timer, loop sensor, or similar device) must not be employed. A Warning placard stating, “WARNING - Moving Gate has the Potential of Inflicting Injury or Death - Do Not Start the
Gate Unless the Path is Clear” must be placed adjacent to the gate operator controls.
CAUTION
While compliance is possible with Type C, which is a low force limiting clutch, the SlideSmart operator does not utilize a clutch, therefore this option is not available.
Similar compliance issues exist with a Type E device (audio warn before operate alarm). A Type
E device is permitted as a means of secondary entrapment protection by UL 325 in Class IV applications, but it is not recommended by HySecurity because a buzzer warns, but cannot protect against possible entrapment. HySecurity highly recommends, even for Class IV use, that secondary entrapment protection (edge or photo-eye sensor) devices be installed to detect possible entrapment.
Revision D Safety Requirements S-7
Emergency Stop Button
E
MERGENCY
S
TOP
B
UTTON
An emergency stop button that is accessible from the outside of the operator is a requirement for compliance with UL 325 Safety Standards. The red emergency stop button is located inside a hole cutout on the SlideSmart cover.
Red
Emergency Stop
Pressing the emergency stop button while the gate is opening or closing disables the automatic close timer and stops gate travel. The gate travel remains stopped until the operator receives an open or close signal.
Make sure all users of the gate know where the emergency stop button is located.
A screwdriver or hex key can be used to press lightly on the switch to activate it.
E
MERGENCY
R
ELEASE
Make sure and teach all users how to turn off electric power and how to move the gate manually. SlideSmart allows a gate to be pushed manually when the operator’s DC power is turned off. ( You DO NOT need to turn
AC power off to manually push the gate.
) See NOTE.
When you turn DC power off, the following occurs:
• The motor disengages which makes it easier to push the gate open (or close)
• The GATE NO LOAD (FAULT 4) appears on the display
• The position sensor is active and established limits are remembered
To turn DC power on, take the following steps:
1. Make sure the gate is not moving.
2. Flip the DC power switch on.
3. Clear any faults by pressing STOP or RESET.
NOTE
If you turn OFF both power switches (AC and DC) and manually move the gate, the operator will search for the target to re-establish its limits. When you turn AC & DC power back ON, the operator will cycle the gate and search for the target magnet (its “home” position).
An operator with the DC power switch ON and the AC power switch OFF still functions normally, but “NO AC” flashes in the display. If you “push” the gate, it will push back because the position sensor is active and the motor is engaged.
S-8 SlideSmart DC Installation and Reference Manual Revision D
Wind Load Factors & Site Prep
W
IND
L
OAD
F
ACTORS
& S
ITE
P
REP
Wind load is always a factor when considering the appropriate gate for a particular site. Solid gate panels produce a larger wind load than gates with slats or open decorative features. If you are installing a gate operator in high wind areas, the gate design will affect the load on the gate operator. Because wind force acts the same as an obstruction, it is important that gates be designed to present a relatively low surface area for the wind to push on the gate panel.
If the gate is heavy and near the weight capacity of what the gate operator can handle (see specifications for
SlideSmartDC on the back cover), make sure it has an open design that allows wind to flow through it. A solid or semi-solid gate design under certain wind load conditions may cause damage to the gate operator and is not covered by the HySecurity Limited Warranty.
Several factors play into the calculations of the wind load on a gate panel. To find out the maximum wind speed in areas around the United States, search for US government wind speed maps on the internet. If you don’t know how to calculate for wind load, ask a mechanical engineer or site architect for assistance prior to installing the gate operator and gate panels.
SlideSmartDC incorporates a primary Type-A inherent entrapment sensor (IES) into its design per UL 325
Safety Standards. (More information about adjusting the adaptive IES software can be found in this manual under, Adjusting the IES Sensitivity.) When the IES trips, it sends a signal to the gate operator to stop and reverse direction. This feature may be falsely triggered in excessively windy conditions because the wind itself, acting over the surface area of the gate panel, can provide the necessary force to trigger the IES.
!
CAUTION
Do not adjust IES sensitivity to accommodate for inappropriately designed gate panels. Loss of
IES sensitivity increases mechanical wear on the gate hardware and the gate operator. It may also pose a safety hazard. Compensating for wind loads by adjusting the IES may set the IES sensitivity to a level which, when encountering an obstruction, ignores the obstruction and fails to reverse direction. For more information, refer to Adjusting the IES Sensitivity.
Revision D Safety Requirements S-9
Safety Notices
S
AFETY
N
OTICES
The following four levels of safety notices are used where applicable within this manual; each notice contains information specific to the situation.
!
DANGER
Indicates death or serious injury will occur if the hazardous situation is not avoided.
!
WARNING
Indicates death or serious injury could occur if the hazardous situation is not avoided.
!
CAUTION
Indicates mild or moderate injury could occur if the hazardous situation is not avoided.
CAUTION
Indicates damage to equipment is probable if the hazardous situation in not avoided.
C
OMMON
I
NDUSTRIAL
S
YMBOLS
The following international safety symbols may appear on the product or in its literature. The symbols are used to alert you to potential personal injury hazards. Obey all safety messages that follow these symbols to avoid possible injury or death.
Attention
- Take Note -
- Danger -
Keep Away
Entrapment
Zone
Possible
Pinch Point
S-10 SlideSmart DC Installation and Reference Manual Revision D
Site Overview & Planning
Installation
Chapter 1
S
ITE
O
VERVIEW
& P
LANNING
Keypad or Card Reader
Mount access control devices at least 6ft beyond gate.
WARNING
Be sure to place the
WARNING signs on both sides of the gate. For your records, take a photograph of the completed installaon site.
Attach WARNING Signs
Public Side
Pedestrian gate
Make sure a separate walkthrough entrance is available and its pedestrian path is clearly designated.
Photo eye
Maximum 2
¼
” (57mm) width between vertical bars
Edge sensor on leading edge
V track
Physical stop
Edge sensor on trailing edge nd Ga te opening
Earth ground
Target magnet on chain
Photo eye (entrapment protection shown in four locations)
Physical stop - weld stops at both ends of V track
Figure 1-1.
To comply with ASTM F2200, a screened wire mesh extends to the top of the gate or to a minimum height of 6 ft. (183cm) if a 2¼” (57mm) or larger gap exists between the vertical bars.
Secure Side
SlideSmart DC 15
Duty cycle: continuous
Power, single phase: Switch selectable
115 volts, 3 amps, 50/60 Hertz
230 volts, 1.5 amps, 50/60 Hertz
Motor: ½ hp
Gate speed: 1ft/s
Gate weight: Maximum 1500lbs (675kg)
Note: For SlideSmart DC Solar operators, refer to www.hysecurity.com
SlideSmart DC 10F
Duty cycle: continuous
Power, single phase: Switch selectable
115 volts, 3 amps, 50/60 Hertz
230 volts, 1.5 amps, 50/60 Hertz
Motor: ½ hp
Gate speed: 2ft/s
Gate weight: Maximum 1000lbs (450kg)
Revision D Installation 1-1
Site Overview & Planning
Pad Condition
1. Follow the local building codes to identify the frost line and determine the required depth of the concrete pad.
HySecurity recommends a minimum
16-inch depth with a minimum 2-inch extension above ground level. Refer to
2. Before pouring the pad, consider conduit placement so it fits within the confines of the 6.9 x 12-inch cutout in the SlideSmart base as shown in
Figure 1-2. Run separate conduits for:
6.4"
(16.3cm)
10 .
5"
(26.7cm)
Area cut out for conduit
6.9 x 12 "
(17.5 x 30.5cm)
Chain
#40 Roller
Gate
21"
(53.3cm)
• high voltage wiring (115-230V supply power) including equipment ground
• low voltage wiring (12V and 24V accessory power)
• vehicle loop control wiring
• master/slave connections
• earth ground (NEC/NFPA)
1.6"
(4.1cm)
Concrete pad
10.38"
(26.4cm)
19" minimum
(48.3cm)
Figure 1-2.
Slotted holes (4x) for concrete anchors:
½ - 13 x 3½"
3. Extend conduit height 2-inches (5cm) above the pad (4-inches (9cm) above ground level). Make sure the concrete forms are square with the gate and the pad is level. The operator footprint, with covers, is
approximately an 18-inch square (4.7cm). See Figure 1-2 for the minimum pad dimensions.
SlideSmart DC operator
Ground wire & rod
Chain
3 max.
(91.4cm)
Ground lug
Conduit runs
2" (5cm) above concrete pad
Minimum pad
height is 2" (5cm)
above grade level.
20.7"
(52.6cm)
Grade level
Vehicle loop control wires
Extra conduit
(Master/Slave power)
(Conduit may be shared with low voltage wires)
Low voltage/Communicaon wires
Consult local codes for proper depth
Concrete pad
(depth set per local codes)
High voltage wires
Main AC power
Grounding rod depth at
10 (3m) or per local code
Cut-away view
Figure 1-3.
1-2 SlideSmart Installation and Reference Manual Revision D
Site Overview & Planning
Using an Existing Pad
In many applications, SlideSmart may be a replacement operator for an existing gate system.
Make sure the pad is level and inspect the pad for:
• Compliance with local building codes.
•
Appropriate distance from the gate. See Figure 1-4.
•
Appropriate dimensions (See Figure 1-2) for
SlideSmart installation.
• Durability.
Chain to Gate
Ideal distance = 3¾" (9.5cm)
Minimum distance = 2½" (6.4cm)
Chain height
Cut out if rear install
To use an existing pad, take the following steps:
1. Remove any existing equipment from the pad.
2. Measure the pad to ensure it is sized properly for
SlideSmart.
3. Check the mounting hole locations and re-drill, if necessary.
4. Follow the steps in
.
7 ¾"
(19.7cm)
Concrete pad
Side View
Figure 1-4.
CAUTION
Consider positioning the operator so existing conduit enters the cutout in the SlideSmart base plate. Cutting small holes in the plastic base plate and cover for pre-existing conduit is permissible. Two 0.875-inch (22mm) diameter holes for running conduit are also provided on
both sides of the chassis. See Figure 1-5.
Gate
Grade level
Revision D Installation
Conduit cut outs
Figure 1-5.
1-3
Site Overview & Planning
Front Installation
The most common and cost efficient type of installation is the front installation.
Physical stop (2x)
Chain
Secure Side
Chain bracket (2x)
Note: Several different ways to mount the SlideSmart operator exist. A few are shown here.
For more detailed drawings, refer to the
in the Appendix.
Chain
Optional
50Ah batteries
1-4
Base extension mount Post mounted
Figure 1-6.
Post mounted with base extension
SlideSmart Installation and Reference Manual Revision D
Site Overview & Planning
Rear Installation
A rear installation requires additional idler wheels and gate brackets, but it provides aesthetics as the chain is not visible along the gate.
Chain
OPEN
Idler wheel
Sprocket
OPEN
Target magnet
View shows how to feed chain over sprocket and idler wheel for a rear installation.
Target magnet position between idler wheel and sprocket when gate is fully closed.
Le Hand Ga opening te
5"
8"
Chain & bracket position:
8" (20cm) and 5" (13cm)
Revision D distance of 1 foot (31 cm) from the end of the gate when gate is fully closed.
Gate
Chain to Gate
Ideal distance = 3¾" (9.5cm)
Min. distance = 2½" (6.4cm)
17
½"
(44.5cm)
Lengthen the chain access slot by cung the cover on the chain side only.
8 "
(20.3cm)
Chain height
7 ¾"
(19.7cm)
Side View
Figure 1-7.
Concrete pad
Installation 1-5
Unpacking the Operator
U
NPACKING THE
O
PERATOR
Lock
Cover
Service Outle
115VAC, 15A t
Base plate
Figure 1-8.
Prepare the gate operator for installation. See Figure 1-8.
1. Open the top of the box and remove packing materials.
2. Cut open the box to access the operator.
3. Lift the cover up and off the base of the operator. DO NOT lift the cover by its lock.
1-6 SlideSmart Installation and Reference Manual Revision D
Concrete Pad Mount
C
ONCRETE
P
AD
M
OUNT
6.4"
(16.3cm)
Chain to Gate
Ideal distance = 3¾" (9.5cm)
Minimum distance = 2½" (5cm)
Chain
#40 Roller
Gate
Gate support posts
Left hand gate
(shown in full CLOSE position)
Chain resides inside gate support posts parallel with the gate.
10 .
5"
(26.7cm) Conduit cut out
SlideSmart
Gate support posts
21"
(53.3cm)
1.6"
(4.1cm)
Concrete pad
10.38"
(26.4cm)
19" minimum
(48.3cm)
Mark the center of slotted holes (4x) for concrete anchors:
½ - 13 x 3½"
Direction of gate movement when opening
Figure 1-9.
Install the operator, by taking the following steps:
1. Place the operator on the pad to best suit the conduit as shown in Figure 1-2. Use the operator as a template and center it on the pad. The chain path must be parallel with the gate.
2. Assess any limitations in the chain path such as gate support posts. Adjust the operator’s location as required.
Mark the mounting locations based on gate, operator, and chain requirements. Mark the drill point at the center of the slot to allow for adjustments.
See Figure 1-4 and Figure 1-9.
3. Remove the operator from the concrete pad and drill the holes for the concrete anchors. See Tip .
4. Mount the operator with four ½ - 13 x 3½-inch
concrete anchors as shown in Figure 1-10.
5. For additional types of mounting options, refer to the
Appendix.
Concrete pad
Grade level
Figure 1-10.
½ - 13 x 3½" concrete anchors (4x)
Concrete base
Tip : To keep pinpoint accuracy while drilling the mounting holes in the concrete, use a
3/16-inch bit to pilot the holes and then move to a ½-inch drill bit.
Revision D Installation 1-7
Gate Bracket and Chain Installation
G
ATE
B
RACKET AND
C
HAIN
I
NSTALLATION
Trailing edge view
1-8
7¾"
(19.7cm)
Leading edge view
Chain bracket
Eye bolt
Connector link
1. Secure the gate to prevent movement.
2. Measure for proper chain alignment BEFORE welding the brackets to the gate. Make sure the chain will run horizontal to the ground and parallel with the gate.
3. Weld the chain bracket in two places: leading edge and trailing edge. You may need to cut the length of the bracket to achieve proper chain alignment. Gusset plates are provided and can be welded to the bracket for added support.
4. Attach the eye bolts to the brackets, and then attach the connector link between the chain and eye bolt.
the bracket on the opposite end of the gate. Make sure the chain is horizontal to the ground and parallel to the gate.
6. Adjust the nuts on the eye bolt to tighten the chain (minimize sag, but avoid overtightening). Chain sag should not exceed 3 inches (76mm) from its anchor point.
Figure 1-11.
SlideSmart Installation and Reference Manual Revision D
Aligning the Chain
1. For a front installation, feed the chain over the sprocket and beneath the idler
2. For a rear installation, see Figure 1-7.
3. In either situation, make sure the chain is properly aligned horizontal to the ground and parallel to the gate.
Keep chain horizontal to the ground.
Idler wheel
Sprocket
Target sensor
(RH gate)
Gate Bracket and Chain Installation
Target sensor
(LH gate)
Figure 1-12.
SIDE VIEW
CORRECT INSTALLATION
Chain to gate
Ideal distance = 3¾"
(9.5cm)
TOP VIEW
Revision D
Too close to gate
INCORRECT
CORRECT
INCORRECT
Figure 1-13.
Installation
INCORRECT INSTALLATION
1-9
Gate Bracket and Chain Installation
Connecting the Battery and Turning DC Power ON
1. Connect the red battery wire to its
2. Turn DC power ON. The USAGE
CLASS appears the first time power is supplied to the operator.
3. To navigate within the Setup
Menu, use the SELECT, NEXT, and PREV buttons as shown in
Connect red battery wire
ON
DC
POW
OF
Turn DC power ON
Figure 1-14.
Note: Programming the Setup Menu is usually a one-time occurrence unless factory defaults are reinstated through the Installer Menu. The RESET and MENU buttons do not function during the initial configuration of the Setup Menu.
Table 1-1. Menu Mode Navigational Buttons
To edit the Menu
Press SELECT.
Two top characters blink.
To navigate through the SELECTIONS
Press NEXT.
Continue pressing NEXT to view all selections.
To choose what is on the display
Press SELECT.
blinking characters become static.
To navigate between menus
Press NEXT or PREV.
Advance - press NEXT.
Previous - press PREV.
Several sequential displays present information which must be configured before SlideSmart will function.
Once the configuration is complete, the information is retained even when a power loss occurs.
1-10 SlideSmart Installation and Reference Manual Revision D
Gate Bracket and Chain Installation
Programming the Initial Setup Menu
Several sequential displays present information which must be configured before SlideSmart will function.
Once the configuration is complete, the information is retained even when a power loss occurs.
Table 1-2. Menu Mode Navigational Buttons
To edit the Menu
Press SELECT.
Two top characters blink.
To navigate through the SELECTIONS
Press NEXT.
Continue pressing NEXT to view all selections.
To choose what is on the display
Press SELECT.
blinking characters become static.
To navigate between menus
Press NEXT or PREV.
Advance - press NEXT.
Previous - press PREV.
UC 0
USAGE CLASS
OPEN CLOSE STOP MENU RESET
SELECTIONS
0 - No Usage Class set.
1 - Single Family residential up to four units.
2 - Multi-family, hotel, etc.
3 - Industrial use, not for general public.
4 - Guarded and monitored facility, not for general public.
PREV NEXT SELECT
SH 0
GATE HANDING
SELECTIONS
0 - No handing set. Gate will not move until handing is set.
Looking at the gate from the secure side, choose:
L - If the gate slides open to the left.
R - If the gate slides open to the right.
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
WT 0
GATE WEIGHT (LB)
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
Figure 1-15.
SELECTIONS
0 - Gate weight not set.
SlideSmart DC 15
1 - Gate weight: 0 to 400lbs (0 to 181Kg)
2 - Gate weight: 401 to 800lbs (182 to 363Kg)
3 - Gate weight: 801 to 1100lbs (363 to 499Kg)
4 - Gate weight: 1101 to 1500lbs (499 to 680Kg)
SlideSmart DC 10F
1 - Gate weight: 0 to 250lbs (0 to 114Kg)
2 - Gate weight: 251 to 500lbs (114 to 227Kg)
3 - Gate weight: 501 to 750lbs (227 to 340Kg)
4 - Gate weight: 751 to 1000lbs (341 to 454Kg)
Once the gate weight is set, the operator is ready to learn
OPEN and CLOSE limits.
Revision D Installation 1-11
Gate Bracket and Chain Installation
Establishing the OPEN & CLOSE Limits
After programming the initial setup menus, the operator needs to establish the OPEN and CLOSE limits.
LEARN OPEN
INCHES: +XXX.X
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
LEARN CLOSE
INCHES: - XXX.X
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
HYSECURITY
GATE CLOSED
The LEARN LIMITS display automatically appears after you set the gate weight. To set the open and close limits, take the following steps:
1. Hold the OPEN button until the gate slides to full open.
Release the OPEN button. Note that if you go too far, you can press CLOSE to reverse direction. Press STOP twice to store the open stop location in memory.
Note: Do not set limits at the physical OPEN and CLOSE stops.
Leave a 1 to 2-inch (2.5 - 5cm) gap to allow some slack and give in the chain. This will help prevent chain wear and avoid stress on gear hardware.
2. Hold the CLOSE button until the gate slides to full close.
Release the CLOSE button and press STOP twice. The full close stop is retained in memory.
Note: Pressing OPEN will reverse direction.
3. GATE CLOSED appears on the display and ALERT 15 flashes until the target magnet is installed and its location
stored in memory. See Installing the Target Magnet
.
Note: NO AC POWER flashes after the gate status display if the
AC power has not been connected or the lower power switch is turned off.
SlideSmart never forgets its limits. AC or DC power can be lost and SlideSmart always remembers where to stop the gate within a
¼-inch of its established limit. The only exception occurs when a chain is replaced or damage occurs to the operator itself. To reset limits, see
Resetting the OPEN and CLOSE Limits
.
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
Figure 1-16.
CAUTION
Do not install the target magnet before setting the OPEN and CLOSE limits. If the target magnet is installed before setting the limits, the target magnet can get wound around the roller sprocket which will damage the SlideSmart operator and void the Limited Warranty.
1-12 SlideSmart Installation and Reference Manual Revision D
Installing the Target Magnet
NOTE: Only one magnet is required. Two target sensors are provided for
LH & RH gate applications, but only one sensor is used.
Mark the chain
Gate Bracket and Chain Installation
Figure 1-17.
1. With the gate CLOSED, mark the chain link directly across from target sensor that is closest to the trailing edge of the
2. Press the OPEN button to move the chain a few feet and then press STOP.
3. Find the mark on the chain link and count about 4 fixed links toward the operator (approximately 3 inches, 76mm).
Sensor
4. Remove the screw from the target magnet.
5. Fasten the target magnet to the chain link as shown in
Figure 1-18. Make sure the large white centerpiece is facing
toward the operator. Insert the screw and tighten it securely.
3" (76mm)
4 links
Magnet
Large white centerpiece
Install one target magnet
Figure 1-18.
CAUTION
To avoid damage to the idler wheel, the head of the screw must be flush with the chain rollers.
6. Press OPEN and wait for the gate to travel and stop at its full open position.
7. Press CLOSE. As the gate approaches the full close position, the target magnet passes the target sensor and an audible beep is heard. Read the NOTE below, and then proceed to step 8 to verify that the operator has learned its limits.
NOTE
If “ALERT 15 - NO TARGET” appears on the display after the target magnet has been installed and a full gate cycle completed (steps 6 & 7), it means that the target magnet has not been detected by the operator. Check chain alignment and make sure the target magnet is posi-
tioned properly and passes across the face of the sensor. See Figure 1-18. Repeat steps 6 and 7.
Revision D Installation 1-13
Gate Bracket and Chain Installation
8. To verify that the operator recognizes the target magnet, turn off both DC and AC power switches and watch the display go blank. Then, turn both switches on. The operator beeps indicating Limit Relearn
Mode. The gate then travels about 6 inches (15cm) in the open direction and stops. The buzzer beeps again and the gate travels in the close direction at a rate of ½ ft/s until the target magnet passes the target sensor. The buzzer sounds one last time, the operator resets, and “GATE CLOSED” appears on the display.
9. If “LEARN OPEN” appears, then the target magnet was not detected. Check chain alignment and make
still having difficulty with the operator learning its limits, re-install the target magnet. See
Establishing the OPEN & CLOSE Limits on page 1-12.
F
RONT
I
NSTALLATION
Trailing edge of gate
(Gate shown in full
CLOSE position)
Roller chain sprocket
Second target sensor is not used
Position of the target magnet when the gate is fully closed.
Idler wheel
Target sensor
(LH gate)
Figure 1-19.
CAUTION
When the gate is CLOSED, the target magnet should stop between the idler wheel and the roller chain sprocket. The target magnet MUST NOT enter the sprocket teeth. See
1-14 SlideSmart Installation and Reference Manual Revision D
R
EAR
I
NSTALLATION
Location of target on a rear installation with the gate in full CLOSE position.
installation for a left hand gate.
OPEN
Chain motion
OPEN
Gate Bracket and Chain Installation
Position of the target magnet when the gate is fully closed.
Figure 1-20.
Revision D Installation 1-15
Gate Bracket and Chain Installation
This page intentionally blank.
1-16 SlideSmart Installation and Reference Manual Revision D
Installing the Earth Ground
Power
Chapter 2
I
NSTALLING THE
E
ARTH
G
ROUND
An earth ground refers to the grounding rod and accompanying equipment ground which need to be installed to safeguard against potential electrical shock and damage to personnel and equipment.
!
DANGER
The potential for lightning discharge exists with all gates, fences and gate operators. National Electric Code (NEC) requires a separate earth ground in addition to the required equipment ground.
HySecurity recommends grounding the operator with a separate earth ground rod to shield the operator against electromagnetism and other electrical signals that may cause erratic operation with or damage to the
Smart DC Controller.
NOTE
If you do not ground the operator with a separate earth ground rod, you risk voiding the
Limited Warranty.
For earth grounding requirements, refer to the National Fire Protection Association (NFPA) 780 - Standard for the Installation of Lightning Protection Systems . Highlights of the standard include.
• The ground rod is a solid copper rod: minimum requirements: ⅝" (16mm) diameter and 10 feet (3m) in length.
• The ground rod is driven into the earth (refer to local codes for proper depth requirements).
• The ground rod is electrically bonded to the chassis with a single length of un-spliced 6AWG copper wire less than 3 feet (91cm) long.
• Local jurisdictions may impose additional requirements above the NEC and NFPA 780. Consult the local codes and regulations regarding requirements in your area.
Revision D Power 2-1
Installing the Earth Ground
Take the following steps to comply with NEC and NFPA
780 standards:
1. Install a grounding rod per local building codes. See
2. Attach a large earth ground wire (6AWG) from the grounding rod to the lug nut on the base of the chassis.
• New site : Run the 6AWG wire through the concrete base and into the cutout on the chassis base.
• Existing site : Run the 6AWG wire beneath the rear cover.
Properly grounding the gate operator is critical to gate operator performance and the life of its electrical components. Use sufficient wire size during installation.
Refer to
Wiring 115VAC Power or Wiring 208/230VAC
Consult local codes for proper depth.
3 ft
Lug nut
Figure 2-1.
Ground wire and lug nut
2-2 SlideSmart DC Installation and Reference Manual Revision D
Wiring AC Power
W
IRING
AC P
OWER
!
DANGER
Turn off AC power at the source (circuit breaker panel) before accessing the wires in the SlideSmart junction box. Follow facility Lock Out/Tag Out procedures. Make sure both the DC and AC power
switches, on the side of the SlideSmart control box are in the off position. See Figure 2-2.
!
CAUTION
Wiring of gate operators must conform to the NEC standards and comply with all local codes.
If you plan to connect to 208/230VAC power, read the WARNING in Figure 2-2. The voltage selector switch on the AC Power board must be moved to the 230V position or damage to the operator will occur and void the Limited Warranty.
Place the power switches in the
OFF position.
WARNING
DO NOT connect the 115VAC service outlet to 208/230VAC power supply wires. To use the 115VAC service outlet on a 208/230VAC installation, the electrician needs to run an extra neutral wire to the operator from the power source and wire the service outlet per code.
Service outlet
115 VAC wires for the service outlet.
O
DC
POW
OF
O
AC
POW
OF
115VAC, 15A t
Junction box cover and label
NOTE: For 208VAC a separate transformer option kit may need to be ordered.
Revision D
Figure 2-2.
Power
High voltage protection cover.
Voltage selector switch is factory set to 115V.
If power input is 208/230V, move the switch so 230V appears and change the label on the junction box.
2-3
Wiring AC Power
Wiring 115VAC Power
For standard 115VAC power connection:
• Verify AC power supply wires and low voltage (12V & 24V accessory power wires) run through two separate conduits. The higher voltage from the AC power supply may cause interference and anomalies in SlideSmart operation if the high and low voltage wires are routed through the same conduit.
• Maximum gate operator current draw is 3 Amps on a dedicated 115VAC circuit (20A dedicated circuit is recommended).
• Make sure proper wire size is used. The following table shows the maximum allowable wire run from the power source to the operator for various wire sizes.
Table 2-1. Wire Gauge versus Run
AC Power
One operator 115V
Two operators 115V
14 gauge wire
730 ft (223 m)
460 ft (140 m)
12 gauge wire
1200 ft (366 m)
750 ft (228 m)
10 gauge wire
1900 ft (579 m)
1160 ft (354 m)
Note: Table 2-1 assumes a dedicated circuit with an accessory power load up to 2A.
Additional loads require that the wire size be increased or the distance of the run be decreased.
To connect to 115VAC power, take the following steps:
1. Make sure the AC power is turned off at its source and the DC and AC power switches on the operator are in the off position.
2. Access the input power wires and service outlet wires by removing the two Phillips-head screws that secure
the high voltage junction box cover. See Figure 2-2.
NOTE
The service outlet wires are solid copper and are labeled and bound together to keep them separate from the AC power switch wires.
3. Wire nut or crimp bond the power supply wires to the black and white lead wires coming from the AC
power switch (no label). See Figure 2-2.
4. Wire nut or crimp bond the equipment ground wire to the green ground wire in the junction box.
5. To activate the 115VAC service outlet, include the black and white outlet lead wires and the green ground wire in the connections made above.
6. Neatly organize all wire connections and replace the high voltage junction box cover. Secure it with the two
Phillips-head screws.
Wiring 208/230VAC Power
!
CAUTION
All SlideSmart operators are shipped from the factory as 115VAC units. When connecting to
208/230VAC power, the voltage selector switch on the AC power board must be moved to the
230V position or damage to the operator will occur and void the Limited Warranty.
2-4 SlideSmart DC Installation and Reference Manual Revision D
Wiring AC Power
For the 208/230VAC power connection:
• Verify AC power supply wires and low voltage (12V & 24V accessory power wires) run through two
separate conduits as discussed in Wiring 115VAC Power .
• Maximum gate operator current draw is 1.5 Amps on a dedicated 208/230VAC circuit (20A dedicated circuit is recommended).
• Make sure proper wire size is used. Refer to the following table.
Table 2-2. Wire Gauge versus Run for 208/230VAC
AC Power
One operator 230V
Two operators 230V
14 gauge wire
2095 ft (639 m)
1465 ft (446 m)
12 gauge wire
3350 ft (1021 m)
2350 ft (716 m)
10 gauge wire
5300 ft (1615 m)
3750 ft (1143 m)
Note: Table 2-2 assumes a dedicated circuit with an accessory power load up to 2A.
Additional loads require that the wire size be increased or the distance of the run be decreased.
To connect to 208/230VAC power, take the following steps:
1. Make sure the AC power is turned off at its source and the DC and AC power switches on the operator are in the off position.
2. Remove the High Voltage Protection cover by unscrewing the two Phillips-head screws
that secure it. See Figure 2-2.
3. Toggle the voltage selector switch from 115V to 230V. Replace the High Voltage cover and
4. Access the input power wires by removing the two Phillips-head screws that secure the High
Voltage Junction Box Cover. See Figure 2-2.
5. Wire nut or crimp bond the power supply wires to the black and white lead wires coming from the AC power switch (no label).
6. Wire nut or crimp bond the equipment ground wire to the green ground wire in the junction box.
Voltage selector switch set to 230V .
30V
Figure 2-3.
!
DANGER
Do not connect the 115VAC service outlet to 208/230VAC power supply wires. To use the service outlet with 208/230VAC supply power, a separate neutral wire (white) must be run from the power source. Follow guidelines according to the National Electrical Code Article 250.
7. Neatly organize all wire connections and secure the High Voltage Junction Box Cover with the two
Phillips-head screws.
8. Place the 230V 1Ø label on the High Voltage Junction Box Cover over the 115V 1Ø label.
Revision D Power 2-5
Using A Solar Powered Operator
U
SING
A S
OLAR
P
OWERED
O
PERATOR
HySecurity offers a solar version of the SlideSmart operator in 1ft/s or 2ft/s models. The solar models have different internal wiring and include software programmed for solar use. The Smart DC Controller has a builtin charger which allows a 24V solar panel (or two 12V panels) a direct connection to the SlideSmart operator with no additional electronic devices required.
NOTE
Solar panels are NOT included in the purchase of the SlideSmart DCS 15 and 10F operators.
Also, adapting a standard SlideSmart DC operator to a solar application is not recommended.
For ease of installation and proper functionality, be sure to order a solar model, SlideSmart
DCS, for a solar-powered site.
To plan a solar-powered site, read through this entire section. Keep in mind that the solar
SlideSmart DCS operator does not have the following components:
• Transformer
• AC power supply board
• AC service outlet
• Various wiring adaptations that are standard in a SlideSmart DC operator
Design Requirements & Considerations
Two standard 8Ah batteries are supplied with SlideSmart DCS and nominally support up to 1,500 feet of gate travel per day based on the following:
•
Battery storage capacity based on 4 solar hours per day. See Figure 2-6.
•
20WATT solar panel system (minimum requirement). See Figure 2-4.
• A gate weight of 1000lbs (454kg), gate length of 30ft (9m), and gate speed of 1ft/s (30.5cm/s)
• Connection to two HY-5A and one multi-code radio receiver. Note that if connected properly, photo eyes are not considered in the power load because the Smart DC Controller only powers the photo eyes when
.
NOTE
The available 50Ah battery option supports up to 9,000 feet of gate travel per day.
The design of the solar-powered site is important in maintaining the highest gate cycle capacity and extending the life of the batteries. The construction of a solar-powered gate and its cycle capacity is significantly affected by the following:
• Energy demand of the peripheral devices. The more energy efficient the device the less power draw occurs to the batteries.
• Sun hours at the site. “Sun hours” relate to the amount of energy delivered by the sun and absorbed by the
• Design considerations must use calculations that are figured for the darkest months of the year (typically
December/January). Higher wattage panels may be required.
• Impediments to the sun’s rays reaching the solar panels. Elements such as, shade, improper alignment, or dirty panels will reduce the amount of power available.
2-6 SlideSmart DC Installation and Reference Manual Revision D
Using A Solar Powered Operator
NOTE
Solar panels must not be shaded (not even partially) or the output power will be significantly reduced. Panels must be kept clean as small areas of sunlight blockage cause a large reduction in output power. Alignment is also critical because the rated wattage output is based on the solar panels being mounted perpendicular to the angle of the sun’s rays midday on winter solstice
(December 21st).
• Extreme temperatures affect battery life. Keep the batteries away from temperatures above 90°F (32°C).
See
Important Considerations for DC-powered Operators .
• Good gate hardware and smooth, unobstructed gate travel lowers the operator’s power draw and serves to extend battery life.
NOTE
Any solar systems that are designed close to the minimum margins will stress and shorten the battery life and risk unreliable operation, especially in periods of inclement weather.
Connecting the SlideSmart DCS to Solar Power
1. Use 14 gauge wire or larger to connect the solar panel(s) within 100ft of the operator. Check NEC and local regulations if other distances apply.
2. Use one 24VDC solar panel or two 12VDC solar panels in series with a total capacity of at least 20W.
Mount them according to the manufacturer's installation instructions.
3. Make sure both DC power switches on the SlideSmart control box are in the OFF position, and then remove the two Phillips head screws that secure the 24VDC cover to the junction box.
4. Wire nut or crimp bond the solar panel wires to the black and red input wires.
5. Wire nut or crimp bond the equipment ground wire to the green ground wire in the junction box.
Minimum
10W Panel
Minimum
10W Panel
12V 12V
Minimum
20W Panel
24VDC
Two 12V panels in series connect to gate operator or
24V
Green
Red
One 24V panel connects to gate operator
Figure 2-4. Solar Panels and Wiring Connections
Black
Revision D Power 2-7
Using A Solar Powered Operator
NOTE
For extended battery backup installation instructions, refer to Installing the Extended Battery
6. Slide the plastic cover off the control box and attach the red spade connector to the battery terminal on the upper DC power switch.
7. Turn both DC power switches ON and program the Smart DC Controller. See Programming the Initial
Control Box
DC Battery & Motor switch (OFF)
Red spade connector
DC Solar Panel switch (OFF)
Input & ground wires
24VDC
2-8
Figure 2-5.
SlideSmart DC Installation and Reference Manual Revision D
Using A Solar Powered Operator
Connecting Peripherals to Solar Operators
CAUTION
The 24VAC power supply shown in Figure 2-6 is not to be used for peripheral connections
because the 24VAC terminals are directly connected to the solar panel inputs. Any peripherals attached to the 24VAC terminals could be severely damaged due to varying voltage levels.
24VDC
1 AMP
MAX
24VAC
1 AMP
MAX
12VDC
1 AMP
MAX
Two power supplies are available for peripheral connections:
24VDC and 12VDC
NOTE: The 24VDC power supply has four terminals that can be used in any combination to draw the available 1A maximum. The 12VDC has two terminals.
Example of Peripheral Amp Draw
0.015A = 3 HY-5A vehicle detectors
0.029A = 1 multi-code radio receiver
0.000A = 4 photo eyes (see NOTE).
0.044A = Total amps needed for site design purposes
COM MON
TERMINALS
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
24VDC
1 AMP
24VAC
1 AMP
MAX
12VDC
1 AMP
HY-5A
FREE EXIT
HY-5A
INSIDE LOOP
Photo EYE COM terminal
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
Photo eye 24VDC
EMERG
OPEN
NOTE: Photo eyes connected to these terminals
SHOW
LEDs receive power when the motor engages which means the draw on the battery is minimal.
USER 1
DC
USER RELAY 1
E +24V
N COM
RADIO OPTION
S
B COM
A
DUAL GATE
COM NO
Electromechanical
USER RELAY 2
USB PORT RS-485
COMMUNICATION
Solid state
Figure 2-6.
HY-5A
OUTSIDE LOOP
HY-5A
CENTER LOOP
LOOP
To connect any peripheral devices to a solar operator, use the 24VDC or 12VDC terminals. Because a solar operator gets its energy from the sun and stores the energy produced by the solar panels in batteries that are constantly discharging, it is important to use peripheral devices that draw and consume as little power as possible.
Revision D Power 2-9
Using A Solar Powered Operator
For example, the Smart DC Controller has specific connections for photo eyes. When you attach photo eyes for entrapment protection, you have the option to wire the photo eyes to the EYE COM and +24VDC. When wired to these connections, the photo eyes only draw power when the motor engages, thereby extending battery life. The same can be said for HY-5A vehicle detectors which draw a minimal 0.005A per detector; compared to box detectors which usually draw, at minimum, 0.009A. For more information on photo eyes,
. To review
information about vehicle detectors, refer to Vehicle Detector Installation Options .
Understanding Gate Activity based on Solar Zones
Use the solar maps to determine the number of solar hours per day that can be reasonably expected in a particular zone. The number of solar hours per day affects the amount of gate travel for a free-rolling gate powered by the SlideSmart solar operator.
NOTE
Remember, the sun is the only source of energy. If you need to increase the amount of gate travel per day (i.e. feet of gate travel), additional solar panels may be required. Also, the greater the battery capacity, the longer the operator can cycle the gate on cloudy days without the recharge provided by the solar panels. Sites requiring more than 1, 500 feet of gate travel per day or those sites located in less sunny climes, need larger capacity batteries. HySecurity offers a
50Ah battery option which provides six times the storage capacity of the standard 8Ah batteries.
Four Week Average, December 7 - January 4
Map Legend
2.5
Sun Feet of gate travel/day hrs/day using 8Ah baeries
2.0
3.5
5.0 3,020 (20W panel)
4.5 1,800 (20W panel)
3.0
2.5
3.0
4.0 1,440 (20W panel)
3.5 1,020 (20W panel)
4.0
5.0
3.5
4.0
3.0 600 (20W panel)
2.5 180 (20W panel)
5.0
The chart is based on a 20 Watt (24VDC) solar panel system with SlideSmart powering a 30 foot (9m), 1000 lbs, 1ft/s gate with the following peripherals attached:
For up-to-date solar isolaon maps, refer to hp://www.nrel.gov/gis/solar.html
•
•
One low current multi-code radio receiver
Two HY-5A vehicle detectors
The number of amps that the peripherals draw coupled with the gate travel occurring throughout the night determines the battery capacity required.
1.7
The number of amps that the peripherals draw coupled with the gate travel during the day , determines the solar panel size needed.
0.0
Arc Circle
4.0
This solar isolaon map recreated courtesy DOE.
Figure 2-7.
NOTE: HySecurity provides a 50Ah battery option for sites where high gate travel and inclement weather are an issue. For sites of this nature, consider a 40W system. A
40W system doubles the feet of gate trave/day that is shown in the chart above.
2-10 SlideSmart DC Installation and Reference Manual Revision D
Important Considerations for DC-powered Operators
I
MPORTANT
C
ONSIDERATIONS FOR
DC-
POWERED
O
PERATORS
• Since the operator is intended to run on batteries, control of the load is important. Gates that move easily and do not bind will drain less energy from the battery, preserving capacity for more cycles during a power failure.
• Be certain to observe polarity when connecting the batteries or adding accessories. Reversed polarity may result in a non-functional operator or damage to a component. Red (+) is positive and black (-) is negative.
If shorted, the batteries will generate a very high current. The batteries are connected in a series circuit:
Join the positive (+) terminal from one battery to the negative (-) terminal of the next battery.
• Batteries have a finite life and age more quickly when exposed to temperatures above 80°F (27°C). Battery temperatures above 104°F (40°C) are damaging and significantly shorten battery life.
• As the batteries age, they will progressively lose their capacity to store energy. If the total amount of back up capacity is critical, plan to replace the batteries after two years of use especially in hot climates. Properly
discard used batteries. Refer to Hazardous Materials and Proper Disposal
.
!
WARNING
Batteries contain sulfuric acid. Acid in your eyes, on your skin, or on your clothing can cause injury and severe burns. If batteries are dropped or damaged dispose of them properly.
• Batteries are rated to perform to capacity at certain temperatures. Variations in temperature affect
performance of the batteries. An example of amp hour performance is shown in Table 2-3. HySecurity
mounts the battery pack near the transformer to provide residual heat around the batteries which guards against amp hour loss.
Table 2-3.
Amp Hour - Example of Battery Performance
Temperature
77°F (25°C)
32°F (0°C)
-22°F (-27°C)
Capacity
100
80
50
• HySecurity uses a permanently sealed AGM-type battery which last much longer than wet cell batteries and needs no maintenance over its life span. Batteries are protected from over discharge by a low voltage sensing circuit. The charger circuit regulates to allow high charger output when the battery is partially discharged. The charger circuit automatically reduces the output to near zero as the batteries become fully charged.
NOTE
The SlideSmart operator stores all User and Installer Menu settings in non-volatile memory
(EEPROM). Configurations are saved if a power loss occurs, and reinstated once power is restored.
Revision D Power 2-11
Important Considerations for DC-powered Operators
Installing the Extended Battery Backup Kit
2-12
Post-mounted operator with base extension
Posts not included in kit
50Ah batteries
Accessory tray
Figure 2-8.
HySecurity offers an extended DC power back up option with two 50Ah batteries. Contact HySecurity parts department to order extended battery backup kit with base extension (P/N MX002141).
To install the extended battery backup kit:
Access window
1. Turn off the DC and AC power switches.
2. Place the accessory tray on the studs inside the
Screws
(4x)
8Ah battery
3. To access the 8Ah batteries and disconnect its wires, cut the two black wire ties and slide the
8Ah batteries through the access window.
Another option is to remove the four screws that hold the control box to the chassis. See
Wire ties
Control box
8Ah battery
Figure 2-9.
!
DANGER
Make sure both the left and right 8Ah DC battery wires are disconnected. Never mix battery sizes, types, or brands. HySecurity strongly recommends that only sealed AGM style batteries be used.
If you plan to remove the batteries from the operator, properly store or discard them. Refer to
Hazardous Materials and Proper Disposal .
SlideSmart DC Installation and Reference Manual Revision D
Important Considerations for DC-powered Operators
4. Place the two 50Ah batteries on the tray.
5. Attach the blue wire from the red terminal on one 50Ah battery to the black terminal on other 50Ah battery.
6. Run the red and black wires
(disconnected from the 8Ah batteries) through the hole in the support bracket.
7. Using the wires supplied in the
50Ah battery kit, attach the red wire to the red positive terminal on the 50Ah battery. Connect its opposite end to the red lead exiting the support bracket.
8. Connect the black wire to the black negative terminal on the
50Ah battery. Connect its opposite end to the black lead exiting the support bracket.
9. Access the Installer Menu on the
Smart DC Controller.
10. Change the Battery Setting (BT) in the Installer Menu to a number 1 (Extended). Follow the steps in the menu tree shown here.
Post-mounted operator with base extension
Revision D
Black
Red
Blue
50Ah batteries
Accessory tray
Figure 2-10.
1. Start at a gate status display.
HYSECURITY
GATE CLOSED
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
2. Access the User Menu, by pressing MENU twice.
LL 0 (OFF)
LEARN LIMIT
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
3. Access the Installer Menu, by simultaneously pressing OPEN and RESET. Release the buttons.
BT 1 (EXTENDED)
BATTERY TYPE
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
4. Use NEXT to navigate to the menu display. Change the setting using the SELECT and NEXT buttons.
Power 2-13
Important Considerations for DC-powered Operators
This page intentionally blank.
2-14 SlideSmart DC Installation and Reference Manual Revision D
Initial Setup
Display and Menu Options
Chapter 3
This section of the manual provides information about the display and menu options. It includes how to:
1. Turn both AC and DC power switches on.
2. Review how to use the Smart DC Controller Buttons in Menu Mode
3. Review Run Mode and Gate Status Displays
4. Access and Configure User Menu Options
• Adjust the Close Timer
• Set the Time and Date
• Set the AC Power Loss Gate Function
• Adjust the Display Contrast
5. Access and Configure Installer Menu Options
• Reset the OPEN & CLOSE Limits
• Set the Open and Close Gate Speed
• Adjust IES Sensitivity
• Enable Fire Department Access
• Reinstate Factory Defaults
I
NITIAL
S
ETUP
Once you have completed the installation of the SlideSmart operator and attached the wired accessories, you’re ready to program the operator. Two different approaches exist:
• Connect a laptop computer to the USB or serial (RS-232) port and upload the gate settings and set the operator menu configurations via the START software.
NOTE
Use a laptop computer at your place of business to conveniently download the free START software from www.hysecurity.com before heading out into the field. This makes it easy to adjust settings using a laptop.
• Manually navigate through the User and Installer Menus using the five buttons located under the LCD display on the Smart DC Controller. The instructions for performing this second option are provided in this section.
Revision D Display and Menu Options 3-1
Initial Setup
Turning Both Power Switches On
AC and DC power switches are located on the outside edge of the control
After Programming the Initial Setup Menu
Installing the Target Magnet , and connecting to main power
), take the following steps:
1. Turn both power switches ON. The gate moves and searches for the target magnet to re-establish the limits.
An audible beep occurs and a red light pulsates next to the OPEN button on the Smart DC
Controller which indicates the system is functioning. If AC power is lost, the rate of flashing slows down. Other indicator lights are described below.
Note: If the target magnet is not detected by the operator,
“ALERT 15 - NO TARGET” or “LEARN OPEN” appears on the display. For more information, refer to
Installing the Target Magnet .
2. When the target magnet is detected, the software version briefly appears on the display, and then one of the following modes appears:
• Gate status - indicates the operator is in Run Mode.
.
• Alert, fault, and error messages - indicates a problem exists with the operator which needs to be resolved before the operator can function properly. Refer to
Smart DC Controller Troubleshooting .
DC Power
Switch
AC Power
Switch
Figure 3-1.
NOTE
The Smart DC Controller can be powered when either switch is turned on. If the DC power switch is OFF the motor and batteries are disconnected. The operator will not function (even though the AC power switch remains on). When the operator is connected to AC power and both switches are turned ON, the charge level of the battery is being monitored and maintained. On a solar-powered operator, the lower power switch connects and disconnects the DC power from the solar panels.
The flashing red indicator light next to the OPEN button on the Smart DC Controller is considered the
‘heart’ beat of the system. It indicates that the
Multi-colored
LED indicates power and gate status.
electronics board is receiving power. When AC power is lost, the rate of flashing slows down. Another indicator light, above the display, is multi-colored and corresponds to the action that the operator is performing:
OPEN
CLOSE
STOP
MENU
RESET
• Green - the operator is stopped.
•
•
Flashing yellow - the operator is running.
Red - the operator has experienced an error.
PREV
NEXT
SELECT
Red LED flashes indicating processor is working.
Figure 3-2.
• Not lit - AC power is lost. Pressing the SHOW
on the board.
3-2 SlideSmart DC Installation and Reference Manual Revision D
Initial Setup
Using the Smart DC Controller Buttons In Menu Mode
The buttons on the Smart DC Controller let you navigate, change, or clear the information in the display
The buttons with text above and below have two functions. Use these buttons to enter operating commands or navigate through the User and Installer Menus. The singular use of these keys is dependent on the operator mode. Three different modes exist:
• Run Mode - gate is operational awaiting commands. Refer to
Using the Smart DC Controller Buttons in
.
• Menu Mode - motor disengages and operator commands are ignored. Data entry, menu navigation, and menu selection can be accomplished via the Controller buttons or through a START software connection using the USB port.
• Fault Mode - alerts, faults or errors appear on the display. Some errors or faults can be reset with the STOP button while more serious faults require the RESET button or cycling power. Faults indicate a need for
diagnosis and resolution. Refer to Smart DC Controller Troubleshooting
.
Two blinking characters indicate that the display will accept changes.
CT 0 (OFF)
CLOSE TIMER
Pressing PREV moves to the previous menu selection.
OPEN
PREV
CLOSE
NEXT
STOP
SELECT
MENU RESET
Pressing RESET clears faults and returns to Run
Mode. A gate status display appears.
The RESET button cannot be
Pressing NEXT advances through the next available menu selection.
Pressing SELECT causes the upper two characters to blink, which indicates the display is ready to accept changes to a menu setting.
Pressing SELECT a second time accepts what appears on the display. The entry mode is complete when the two characters stop blinking.
Pressing MENU returns to Run Mode and a gate status display appears.
The MENU button does not function while the selection is still blinking.
Figure 3-3. Function of the Smart DC Controller Buttons in Menu Mode
Revision D Display and Menu Options 3-3
Run Mode
R
UN
M
ODE
Gate status displays appear when the operator is ready and waiting for a gate operation command. When the menu display is flashing “GATE OPENING” or “GATE CLOSING” a command has been received which starts the motor and drives the gate. The command may come from a variety of sources: a card reader, pushbutton remote, or recognition of a vehicle passing over a free exit loop detector. In all cases, the operator “runs” the motor when it receives a gate operation command.
Understanding Gate Status Displays
HYSECURITY
GATE OPEN
HYSECURITY
GATE CLOSED
HYSECURITY
GATE STOPPED
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
Figure 3-4. Gate Status Displays
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
accessing the User or Installer Menus, you must begin at one of these gate status displays.
NOTE
While accessing the User or Installer Menus, the motor cannot engage and the gate will not move.
3-4 SlideSmart DC Installation and Reference Manual Revision D
Run Mode
Using the Smart DC Controller Buttons in RUN Mode
The Run Mode buttons are distinguished by the fact that their name appears above each button. The
Controller buttons with text above and below function differently depending on the mode of the operator.
Three different modes exist:
• Run Mode - gate is operational awaiting commands.
• Menu Mode - motor disengages and operator commands are ignored. Menu navigation and menu selection can be accomplished using the Smart DC Controller buttons or through a START software
connection via the USB port. Refer to Using the Smart DC Controller Buttons In Menu Mode
.
• Fault Mode - errors, faults or alerts appear on the display. Some errors or faults can be reset with the STOP button while more serious faults require the RESET button or cycling power. Faults indicate a need for
diagnosis and resolution. Refer to Smart DC Controller Troubleshooting
.
HYSECURITY
GATE CLOSED
Pressing OPEN opens the gate.
Pressing CLOSE closes the gate.
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
Pressing STOP stops gate travel.
Pressing RESET clears error codes and returns to Run Mode.
Pressing MENU scrolls through operator status displays and accesses the User Menu. The
CLOSE TIMER display appears which presents the first of twelve programmable displays.
Note : Pressing the MENU button twice, bypasses the operator status displays.
Figure 3-5. Function of Smart DC Controller Buttons in Run Mode
Revision D Display and Menu Options 3-5
Run Mode
Viewing Operator Status Displays
Press the MENU button once and the operator status displays appear in two second intervals. Pertinent
SOFTWARE VERSION
H5.##
DUAL GATE
<MASTER>
Variables
The software version and revision number are hard-coded in the Smart
DC Controller.
Description
Displays the software version when you press RESET or cycle power. You will need the software version when calling Technical Support.
MASTER or SLAVE
(This display only appears when the operator is used in bi-parting gate systems.)
Indicates, in a dual gate setting, whether the operator is set to Master or Slave. The setting is assigned in the
Installer Menu.
OT 15 = SlideSmart DC 15 at 1ft/s
OT 16 = SlideSmart DC 10F at 2ft/s
Indicates and identifies the operator and charger type.
OT <15>D
SLIDESMART DC20
<LEFT> HAND
UC <2>
USAGE CLASS
LEFT or RIGHT Designates which way a gate opens viewed from the operator. If it slides to the left, it is a left-hand gate. Gate handing is established in the initial
Setup Menu.
1, 2, 3, or 4
Note : OT 16 only accepts Usage Class
3 and 4.
Displays the operator’s Usage Class designation per UL 325 standards.
Refer to
.
BT <0>
STANDARD BATTERY
0 = 8Ah (standard factory issue)
1 = 50Ah (optional upgrade)
2 = 110Ah (option)
Number varies depending on the voltage that the charger is providing.
Confirms the operator’s battery type.
If you use to the larger capacity batteries you must configure the operator through the Installer Menu.
See BT - BATTERY TYPE.
Displays the actual charging voltage.
D <32>.0 VDC
BATTERY VOLTAGE
CC<002600>
CYCLE COUNT
CT 0 (OFF)
CLOSE TIMER
One cycle equals a full open and close sequence. Partial cycles are not counted.
Displays the number of cycles the gate operator has incurred. Similar to an odometer, it resets to zero after
999,999 cycles.
The first menu item in the User
Menu. See
Note: You can also access the Installer
Menu from this display. See
. Displays the number of seconds before the open gate initiates
Figure 3-6. Operator Status Displays
3-6 SlideSmart DC Installation and Reference Manual Revision D
User Menu
U
SER
M
ENU
The User Menu consists of several items which can be modified using the Smart DC Controller buttons. Refer
to Using the Smart DC Controller Buttons In Menu Mode .
To access the User Menu, take the following steps:
1. At a gate status display, press the MENU button. The operator status displays scroll past and the CLOSE
TIMER display appears.
CT 0 (OFF)
CLOSE TIMER
Note: To bypass the operator status displays and access the
User Menu, you can press the MENU button twice.
OPEN CLOSE STOP MENU RESET
2. Press the NEXT button to cycle through the available menu items.
PREV NEXT SELECT
the hard-wire connections.
In the pages that follow, a detailed view of the more commonly used menus is provided:
• Adjusting the Close Timer
• Setting the Time & Date
• Setting the AC Power Loss Gate Function
• Adjusting the Display Contrast
For information on how the menu buttons function, review
Using the Smart DC Controller Buttons In Menu
.
Revision D Display and Menu Options 3-7
User Menu
Adjusting the Close Timer
The close timer assigns how many seconds will pass before the operator initiates closure of a fully opened gate after all open commands and reversing sensor inputs have ceased. Every gate operator needs to have the close timer set to a specific number of seconds unless a hard-wired closing device is connected to the unit such as a push button station.
To adjust the time (1 to 99 seconds) it takes before the operator initiates gate closure, take the following steps:
1. At a gate status display, press the MENU button twice. This accesses the User Menu and the CLOSE
TIMER display appears.
2. Use the SELECT, and then NEXT or PREV buttons to navigate and change the number on the display.
CT 0 (OFF)
CLOSE TIMER
Note: Keep the close time at zero if gate personnel operate the gate or the owner plans to use a remote control.
3. To exit the User Menu, press the MENU button.
The gate status appears in the display indicating you have returned to Run Mode.
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
3-8 SlideSmart DC Installation and Reference Manual Revision D
User Menu
Setting the Time and Date
A feature of the Smart DC Controller is its 24-hour, 365 day clock. Make sure it is set to the appropriate time zone. An accurate time and date allows the diagnostic log to date stamp operational data which indicates when
Alerts, Faults and Errors occur. The log helps in troubleshooting and can be viewed via a laptop connected to the USB or RS232 port. For more information, refer to
Smart DC Controller Troubleshooting .
To set or adjust the time or date, take the following steps:
1. At a gate status display, press the MENU button twice. This accesses the User Menu and the
CLOSE TIMER display appears.
2. Press NEXT or PREV until the SET CLOCK display appears.
3. Press SELECT.
CL blinks.
4. Press NEXT or PREV to change the number to 1.
5. Press SELECT to accept the display.
6. The date and time display appears. Use the
SELECT and NEXT buttons in the same manner as before to adjust the date and time.
OPEN CLOSE STOP
PREV
HYSECURITY
GATE CLOSED
NEXT SELECT
CT 0 (OFF)
CLOSE TIMER
MENU RESET
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
Note: A date or time field must be blinking before it can be changed.
7. To accept what appears on the date and time display, press SELECT.
8. To exit the User Menu, press the MENU button. A gate status appears in the display indicating you have returned to Run Mode.
Note: A lithium coin battery, on the Smart DC
Controller board, supports the clock so the date and time is retained even when the main power is turned off.
Replace the battery every five years with a DL 2025,
DL 2032 or CR 2025 or CR 2032 battery. Refer to
.
CL 1
SET CLOCK
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
01/07/11 00:00
^^
1. Start at a gate status display.
2. To access the User
Menu, press the
MENU button twice.
3. Press NEXT until the SET CLOCK display appears. Use the navigational buttons to select 1.
4. Change the time and date using the
NEXT and SELECT buttons.
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
Revision D Display and Menu Options 3-9
User Menu
Setting AC Power Loss Gate Function
The setting in the AC LOSS display determines what action the operator performs during an AC power loss.
The settings help reduce drain on the battery. You can choose between four settings depending on customer preferences.
NOTE
DC Solar Powered units can only be set for AP0 or AP1.
Menu Setting
AP 0 AC LOSS
UPS FAIL OPEN
AP 1 AC LOSS
UPS FAIL CLOSE
AP 2 AC LOSS
AUTO OPEN
AP 3 AC LOSS
NO CLOSE TIMER
Description
Normal gate functions continue until the system detects a battery voltage drop below 21V.
DEAD BATTERY appears on the display and the gate automatically opens. Any pushbutton CLOSE command will close the gate and any open command will re-open the gate.
If the battery continues to diminish and the system detects 18V or less, the system initiates an automatic open cycle. Any new open or close command is ignored and the LCD appears blank. The system remains in this disabled state until reset or the battery recovers to 24V.
Normal gate functions continue until the system detects a battery voltage drop below 21V.
DEAD BATTERY appears on the display and the gate automatically closes. The gate can be opened by a special sequence of a STOP input followed by an OPEN push-button or directly opened with the Fire Department Open command. Any push-button CLOSE command will close the gate. If the battery continues to diminish and the system detects 18V or less, the system initiates an automatic open cycle if not already on a limit. Any new open or close command is ignored and the LCD appears blank. The system remains in this disabled state until reset or the battery recovers to 24V.
The operator automatically opens the gate five seconds after it detects an AC power loss. The gate remains open until AC power is restored. Any push-button CLOSE command will close the gate and any open command will open the gate. When the battery voltage drops below
21V or less, the system initiates an automatic open cycle. The gate will remain open until the battery recovers to 24V.
The operator initially does nothing after it detects AC power loss until it receives an open command. Once an open command is received, the operator opens and remains in that state.
Any push-button CLOSE command will close the gate and any open command will open the gate. When the battery voltage drops below 21V or less, the system initiates an automatic open cycle. The gate will remain open until the battery recovers to 24V.
To designate what you want the operator to do during an
AC power loss, access the User Menu (see User Menu ) and
scroll through the items until the AP (AC LOSS) display appears:
1. Use the SELECT and NEXT buttons to navigate and change the number on the display. Review
Smart DC Controller Buttons In Menu Mode .
2. To exit the User Menu, press the MENU button. A gate status appears in the display indicating you have returned to Run Mode.
AP 0 (AC LOSS)
UPS FAIL OPEN
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
3-10 SlideSmart DC Installation and Reference Manual Revision D
User Menu
Adjusting the Display Contrast
The display contrast can be adjusted from 1 to 9 to increase visibility and ease of use. It is set at the factory to level 5. The text becomes darker as you go up the scale.
NOTE
If extremely low temperatures are expected, set the contrast to a higher number.
To adjust the contrast (1 to 9), take the following steps:
1. At a gate status display, press the MENU button twice. This accesses the User Menu and the CLOSE
TIMER display appears.
2. Press NEXT until the LCD CONTRAST display appears.
3. Use the SELECT and NEXT buttons to navigate and change the number on the display.
4. To exit the User Menu, press the MENU button. A gate status appears in the display indicating you have returned to Run Mode.
LD 5
LCD CONTRAST
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
Revision D Display and Menu Options 3-11
User Menu
3-12
HC 0 (OFF) HOLD HO 0 (OFF) HOLD
SlideSmart DC Installation and Reference Manual Revision D
User Menu
Revision D
RO 0 (OFF) RADIO OPEN/CLOSE BF 2 (ON 2 SEC) W PE 0 (OFF) PHOT
Display and Menu Options 3-13
User Menu
3-14
LD 5 LCD CONTRAST DS 0 (OFF) DIAGNOSTIC LOGS
SlideSmart DC Installation and Reference Manual Revision D
Installer Menu
I
NSTALLER
M
ENU
The Installer Menu consists of several functions which can be modified using the Smart DC Controller buttons or configured through the use of a laptop computer and the START software available from the
HySecurity website.
The Installer Menu options provide more advanced configurations for the SlideSmart operator. Access to the
Installer Menu is through the User Menu. The navigational buttons are the same in both menu modes. To review how to use the navigational buttons on the Smart DC Controller, refer to
NOTE
To access the User or Installer Menus, the operator must be in Run Mode with a gate status showing on the display. The motor cannot be engaged and the gate cannot be moving.
To access the Installer Menu, take the following steps:
Note: The menu items, Usage Class,
Gate Handing, and Gate Weight must be configured before the operator will function. Refer to
HYSECURITY
GATE CLOSED
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
1. Start at a gate status display. To bypass the Operator Status Displays, press the MENU button twice.
In the pages that follow, a detailed view of the more commonly used menus is provided.
• Resetting the OPEN & CLOSE limits
• Adjusting the Gate Speed
• Adjusting the IES Sensitivity
• Enabling the Fire Department
Override
• Reinstating Factory Defaults
CT 0 (OFF)
CLOSE TIMER
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
The CLOSE TIMER display appears indicating you have accessed the User
Menu.
2. To access the Installer Menu simultaneously press OPEN and
RESET.
LL 0 (OFF)
LEARN LIMIT
Release the buttons and the LEARN
LIMITS display appears indicating entrance to the Installer Menu. The
LEARN LIMITS display is the first item in the Installer Menu.
describes the
Installer Menus, supplies the factory defaults, and references the hard-wire connections.
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
For information on how the menu buttons function, review
Using the Smart DC Controller Buttons In Menu
.
Revision D Display and Menu Options 3-15
Installer Menu
Resetting the OPEN and CLOSE Limits
On occasion, the open and close limits may need to be fine-tuned. Resetting the open and close limits is easily accomplished by accessing the Installer Menu. Examples where resetting the limits is necessary , include:
• Replacing the chain or adjusting the chain to the point where it affects the open and close positions
• Removing or replacing the target magnet
• Setting the LEARN LIMITS display to 1 (erases the open and close target positions from memory)
To re-learn limits, take the following steps:
1. At a gate status display, press the MENU button twice. The CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET buttons to enter the Installer Menu.
Release the buttons and the LEARN LIMITS display appears. It is the first item in the Installer
Menu.
3. Press SELECT, and then NEXT to change the setting to 1. Press SELECT again.
LEARN OPEN flashes on the display indicating that operator is ready to relearn the open limit.
4. Hold the OPEN button until the gate reaches the desired open limit. Release the OPEN button. (Note that if you go too far, you can press CLOSE to reverse direction.)
HYSECURITY
GATE CLOSED
OPEN CLOSE STOP
PREV
OPEN CLOSE STOP
PREV
NEXT SELECT
CT 0 (OFF)
CLOSE TIMER
NEXT SELECT
MENU RESET
MENU RESET
1. Start at a gate status display.
2. Access the User
Menu by pressing the
MENU button twice.
5. Press STOP twice to preserve the open stop location.
LEARN CLOSE appears on the display.
6. Hold the CLOSE button until the gate slides to full close. Release the CLOSE button (Note that if you go too far, you can press OPEN to reverse direction.)
LL 0 (OFF)
LEARN LIMIT
OPEN CLOSE STOP MENU RESET
3. Access the Installer
Menu, by simultaneously, pressing the
OPEN and RESET buttons.
PREV NEXT SELECT
7. Press STOP twice. The full close stop is retained in memory. For more information, refer to
Establishing the OPEN & CLOSE Limits .
Note: Do not set limits at the physical OPEN and
CLOSE stops. Leave a 1 to 2-inch (2.5 -
5cm) gap to allow for minimal drift.
8. An ALERT 15 message appears on the display.
To clear the alert, perform a full cycle so the software recognizes the target. Press OPEN, and
LL 1 (ON)
LEARN LIMIT
OPEN CLOSE STOP
PREV NEXT SELECT
MENU RESET
4. Press SELECT and change the setting to
1 using the NEXT button. Press
SELECT again. The
LEARN OPEN display appears. refer to steps 4 through 8.
For more then CLOSE. The gate will stop automatically on the close cycle when it reaches the programmed limit. As the target magnet passes the sensor, the operator beeps and the ALERT 15 message is cleared.
3-16 SlideSmart DC Installation and Reference Manual Revision D
Installer Menu
Adjusting Gate Speed
The gate speed can be increased or decreased a ¼ foot per second from the operator’s default speed.
NOTE
Two options, one for OPEN SPEED the other for CLOSE SPEED, appear in the Installer
Menu. The steps involved in changing the open speed are shown below. The steps to set the close speed are the same, you just need to access the CLOSE SPEED option.
To adjust the gate speed, take the following steps:
1. At a gate status display, press the MENU button twice. The CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET buttons to enter the Installer Menu.
Release the buttons and the LEARN LIMITS display appears. It is the first item in the Installer
Menu.
3. Press NEXT until the OPEN SPEED (or
CLOSE SPEED) display appears. Select the desired setting based on the operator type:
SlideSmart DC 15 0 = 0.75 ft/s
1 = 1.0 ft/s
( Usage Class 3 & 4 only ) 2 = 1.25 ft/s
HYSECURITY
GATE CLOSED
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT SlideSmart DC 10F 4 = 1.75 ft/s
( The DC 10F is designed for 5 = 2.0 ft/s
Usage Class 3 & 4 sites only ) 6 = 2.25 ft/s
Note: Certain speeds are allowed only when the operator’s Usage Class is set appropriately.
4. Use the SELECT and NEXT buttons to navigate and change the speed setting on the display.
5. To exit the Installer Menu, press the MENU button. The gate status appears in the display indicating you have returned to Run Mode.
LL 0 (OFF)
LEARN LIMIT
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
1. Start at a gate status display.
2. Access the User
Menu by pressing the
MENU button twice.
3. Access the Installer
Menu by simultaneously pressing the OPEN and RESET buttons.
OS 5
OPEN SPEED
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
4. Use NEXT to navigate to the menu display. Change the setting using the
SELECT and NEXT buttons.
Revision D Display and Menu Options 3-17
Installer Menu
Adjusting the IES Sensitivity
SlideSmart uses a primary Type-A inherent entrapment sensor (IES) per UL325 Safety Standards. A solid immovable object blocking the gate will trip the IES and cause the operator to stop and reverse (for two seconds) and enter safe mode.
The adaptive IES software monitors the average running motor current while the gate is in motion and reverses the gate when the current exceeds an automatically self-adapting average.
SE 2
IES SENSITIVITY
The IES display, accessed through the Installer Menu, allows you to input a number between 0 and 9. The settings (0 through 6) allow an increasingly higher threshold (amount of headroom) above the average current draw before tripping. For IES settings 7 through 9, the current limit is a fixed relatively high value before the IES will be tripped. The factory setting is 2, which is adequate for most sites.
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
CAUTION
Avoid setting the IES sensitivity to a fixed level (7 - 9 setting). The high motor current required for the IES to trip could cause severe injury or death to people caught in the moving gate.
For IES settings (0 through
6), the motor current is continually being measured and the IES threshold automatically set to trip at the average current plus the additional “headroom” provided by the IES setting selected.
Typical Operaon
Installer Menu: IES Seng = 2
Inial IES threshold
(First gate cycle only)
To prevent false IES trips, the software boosts the IES current threshold for one gate cycle after an IES event, then returns to the normal sensitivity threshold.
0 1 2 3 4 5 6 7 8 9 10 11 12
Motor current threshold
(at IES Seng 2)
Motor current
(under typical operang
condions)
Time (Seconds)
Over time, degrading gate hardware and other site issues, such as road settling or
NOTE: When wind load increases, IES soware adapts and changes the threshold allowance. The IES threshold automacally increases by 50% when the temperature drops below 32°F.
debris on the gate rail
(V-track) can occur. As the gate hardware ages and becomes stiffer, the SlideSmart motor current increases and this may create the need to use a higher IES setting level. The higher settings should only be used on a
TEMPORARY basis until the gate, gate track, or wheels are repaired so the gate rolls smoothly with minimum resistance.
3-18 SlideSmart DC Installation and Reference Manual Revision D
Installer Menu
NOTE
When changing the IES setting, consider the site design and vehicular gate traffic. It is recommended that you use the most sensitive setting while still allowing for reliable gate operation.
Examples of conditions which affect IES sensitivity include:
1. Start at a gate status display.
HYSECURITY
GATE CLOSED
Gate design - For long and/or solid gates in windy environments, large variations in motor current may occur. In these types of scenarios, you may want to use a higher (less sensitive) IES setting.
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
Gate condition - If the gate environment is near salty sea air, rusty wheels or chains might impede gate travel over time. Additionally, gates that are hit and bent may have very stiff areas during travel that cause a large variation in motor current. For these issues, you may want to use a higher (less sensitive) IES setting until repairs are made.
CT 0 (OFF)
CLOSE TIMER
OPEN CLOSE STOP MENU RESET
2. To access the User
Menu, press MENU twice.
Gate maintenance - Gate rollers will deteriorate and begin to fail over time. Gravel or dirt roads will incur more debris in the gate rail or inverted V-track than a paved surface. In poorly maintained gate areas, the chance for false IES trips is higher.
PREV NEXT SELECT
LL 0 (OFF)
LEARN LIMIT
3. To access the
Installer Menu, simultaneously, press
OPEN and RESET
To adjust the IES sensitivity, take the following steps:
OPEN CLOSE STOP MENU RESET
1. At a gate status display, press the MENU button twice. The CLOSE TIMER display appears.
PREV NEXT SELECT
2. Simultaneously, press the OPEN and RESET buttons to enter the Installer Menu.
Release the buttons and the LEARN LIMITS display appears.
SE 2
IES SENSITIVITY
4. Use NEXT to navigate to the menu display. Change the setting using the
SELECT and NEXT buttons.
3. Press NEXT until the IES SENSITIVITY display appears. The factory default setting is 2.
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
CAUTION
Avoid setting the IES sensitivity to a fixed level (7 - 9 setting). The high motor current required for the IES to trip could cause severe injury or death to people caught in the moving gate.
4. Use the SELECT and NEXT buttons to navigate and change the number on the display.
5. To exit the Installer Menu, press the MENU button. The gate status appears in the display indicating you have returned to Run Mode.
If IES errors occur, SAFE MODE or ENTRAPMENT MODE will appear on the display. For more information about troubleshooting, refer to Table 6-1 in the “Reference” section.
Revision D Display and Menu Options 3-19
Installer Menu
Reinstating Factory Defaults
Ten menu configurations are available in the User Menu. Several other items in the Installer Menu let you customize the operator depending on the number of attached accessories and your customer’s needs.
CAUTION
Reinstating factory default clears ALL menu settings stored in the operator and returns them to factory defaults. It is recommended that you save the menu settings before reinstating factory defaults. You can write the settings in a notebook or, if you have a laptop computer, you can use HySecurity’s START software and download the menu settings and save them to a file to upload to the operator at a later date.
To reinstate factory defaults, take the following steps:
1. At a gate status display, press the MENU button twice. This accesses the User Menu and the
CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET buttons to enter the Installer Menu.
Release the buttons and the LEARN LIMITS display appears. It is the first item in the Installer
Menu.
3. Press NEXT until the FACTORY DEFAULTS display appears. The factory default setting is 0.
4. Use the SELECT and NEXT buttons to navigate and change the number on the display to 1.
Note: When you press SELECT to accept FD 1, the factory settings are reinstated immediately and the menu display returns to the initial
Setup Menu. The gate operator will not run until the three menu parameters are entered:
Usage Class, Gate Handing, and Gate
Weight. The limits will also need to be relearned. Refer to
HYSECURITY
GATE CLOSED
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
LL 0 (OFF)
LEARN LIMIT
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
1. Start at a gate status display.
2. To access the User
Menu, press MENU twice.
3. To access the
Installer Menu, simultaneously, press
OPEN and RESET
FD 1 (ON)
FACTORY DEFAULTS
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
4. Use NEXT to navigate to the menu display. Change the setting using the
SELECT and NEXT buttons.
3-20 SlideSmart DC Installation and Reference Manual Revision D
Installer Menu
Enabling the Fire Department Override
Many counties and cities require a Fire Department override system for gate operators. The fire department’s alert system is a separate unit that must be connected to the Smart DC Controller. The FIRE DEPARTMENT
OPEN option must be properly configured through the Installer Menu before the operator will recognize the alert system.
To enable the Fire Department Override, take the following steps:
1. Connect the contact NO from the alert system or key switch to the following Smart DC Controller terminals:
EMERG OPEN
+24V
2. Configure the Installer Menu.
At a gate status display, press the MENU button twice. This accesses the User Menu and the
CLOSE TIMER display appears.
HYSECURITY
GATE CLOSED
1. Start at a gate status display.
3. Simultaneously, press the OPEN and RESET buttons to enter the Installer Menu.
Release the buttons and the USAGE CLASS display appears. It is the first item in the Installer
Menu.
4. Press NEXT until the FIRE DEPARTMENT
OPEN display appears. The factory default setting is 0.
5. Use the NEXT button to change the number on the display to 1 and then press SELECT.
6. To exit the Installer Menu, press the MENU button. The gate status appears in the display indicating you have returned to Run Mode.
OPEN CLOSE STOP
PREV
PREV
NEXT SELECT
CT 0 (OFF)
CLOSE TIMER
OPEN CLOSE STOP
NEXT SELECT
MENU RESET
MENU RESET
2. To access the User
Menu, press MENU twice.
LL 0 (OFF)
LEARN LIMIT
3. To access the
Installer Menu, simultaneously, press
OPEN and RESET
FIRE
COM
STOP
OPEN
CLOSE
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
FO 1
FIRE DEPT OPEN
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
4. Use NEXT to navigate to the menu display. Change the setting using the
SELECT and NEXT buttons.
Revision D Display and Menu Options 3-21
Installer Menu
3-22
UC 0 USAGE CLASS SH 0 GA SH 0 GA
SlideSmart DC Installation and Reference Manual Revision D
Installer Menu
Revision D
CS 1 CLOSE SPEED FD 0 (OFF) FA DG 0 (OFF) DUAL
Display and Menu Options 3-23
Installer Menu
3-24
SG 0 (OFF) SEQUENCED GA CH 0 (AC) CHARGER FO 0 (OFF) FIRE DEPT
SlideSmart DC Installation and Reference Manual Revision D
Installer Menu
Revision D
SE 2 IES SENSITIVITY SS 0 (OFF) IES ST LC 0 (0.0 SECS) LEAF DELA LO 0 (0.0 SECS) LEAF DELA
Display and Menu Options 3-25
Installer Menu
3-26
PO 0 (OFF) PA
SlideSmart DC Installation and Reference Manual Revision D
Installer Menu
SR 1 REVERSE 2S IES SENSOR LOGIC
Revision D Display and Menu Options 3-27
Installer Menu
3-28
OR 1 REVERSE OUTSIDE OBS LOOP IR 1 REVERSE INSIDE OBS LOOP
SlideSmart DC Installation and Reference Manual Revision D
Installer Menu
Revision D Display and Menu Options 3-29
Installer Menu
3-30
ELD 0 (RUN MODE) EXIT ILD 0 (RUN MODE) IN OBS LOOP OLD 0 (RUN MODE) OUT CLD 0 (RUN MODE) CENTER LOOP
SlideSmart DC Installation and Reference Manual Revision D
Smart DC Controller
Chapter 4
This section provides information about the Smart DC Controller board; its inputs for peripheral connections and its monitoring capabilities. This section explains how to:
1. Make connections on the Smart DC Controller
2. Connect Vehicle Detectors
3. Connect Accessory Devices
• Entrapment Sensor
Connections
• Access Controls
• Manual Push-button Station
• User Relays
Revision D Smart DC Controller
Figure 4-1.
4-1
Overview of the Smart DC Controller
O
VERVIEW OF THE
S
MART
DC C
ONTROLLER
The Smart DC Controller uses LED’s to indicate active inputs when AC power is present. For operators that use only DC power, you can push a button to show the active inputs. This button is at the bottom left corner near the EMERG OPEN input.
On a new operator no active inputs should appear until external accessories and wiring are attached. If any
inputs are active before connecting external wiring, refer to Smart DC Controller Troubleshooting
.
4-2
24VDC
1 AMP
MAX
24VAC
1 AMP
MAX
12VDC
1 AMP
MAX
Amp Draw on Power Supplies
Three power supplies are available:
24VDC, 24VAC, 12VDC
A maximum draw of 1A is allowable when combining both spade terminals.
NOTE: The 24VDC power supply has four terminals that can be used in any combination to draw the available 1A maximum.
For example:
Amp Draw & Accessories connected to 24VDC
0.50A = Four photo eyes (for entrapment protection)
0.25A = Keypad with light
0.015A = Three HY-5A detectors
0.76A
COM MON
TERMINALS
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
+24VDC
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
EMERG
OPEN
SHOW
LEDs
24VDC
1 AMP
MAX
24VAC
1 AMP
MAX
12VDC
1 AMP
MAX
USER 1
+24VDC
DC
USER RELAY 1
E +24V
EN COM
RADIO OPTION
S
B COM
A
DUAL GATE
COM NO
Electro-mechanical
USER RELAY 2
USB PORT RS-485
COMMUNICATION
Solid state
Push button to show active inputs when using DC power
HY-5A
FREE EXIT
HY-5A
INSIDE LOOP
HY-5A
OUTSIDE LOOP
HY-5A
CENTER LOOP
LOOP
Figure 4-2. Smart DC Controller Board
SlideSmart DC Installation and Reference Manual Revision D
Overview of the Smart DC Controller
Common Terminal Bus (1 - 8) on the Smart DC Controller board.
The Fire Department Open input is an exception and requires a +24VDC input as well as activation through the Installer Menu. For convenience a +24VDC terminal is located next to the EMERG OPEN terminal.
Table 4-1. Smart DC Controller Board Inputs
Terminal
No.
Input Name Use
1- 8
9
10
11
12
13
14
Common Terminal
Stop * push button
Open * push Button
Close push button
Remote Open and Radio Control**
Partial Open
Photo Eye Open direction
All user inputs are energized when connected to common except
Emergency Open.
Normally Closed (N.C.). input. Jumper to Common if not being used.
Normally Open (N.O.) input. Not for radio or remote access controls.
N.O. input. Connection for a close push-button.
N.O. input. For radio/remote open or close device - Access the User
Menu and program RO RADIO OPEN/CLOSE.
N.O. input. Connection to EYE OPEN and EYE COM. Program PO
PARTIAL OPEN in the Installer Menu to set the distance (from the closed gate position) where the gate stops in a partial open position.
N.O. input. Connection for Photo Eye Open direction. Can be changed to a supervised Normally Closed (N.C.) contact through the Installer
Menu.
15
16
17
Photo Eye Close direction
Free Exit Vehicle Detector
Block Free Exit vehicle detector or Close
Timer
N.O. input. Connection for Photo Eye Close direction. Can be changed to a supervised Normally Closed (N.C.) contact through the Installer
Menu.
N.O. input. Connection for free exit vehicle detector.
N.O. input. Free Exit is only disabled if Close Limit Switch is tripped. If the gate is partially opened, the Free Exit detector will trigger the gate to open fully. The input can be converted in the Installer Menu to alternately disable the Close Timer.
N.O. input. Inside reversing loop.
N.O. input. Outside reversing loop.
18
19
20
21
22
23
Inside Obstruction Vehicle Detector
Outside Obstruction Vehicle Detector
Center Loop (Shadow) Vehicle Detector
Edge Sensor
Photo Eye Common
+24V DC
N.O. input. Center loop function not used for slide gates.
N.O. input. One input works for both directions of travel. It can be changed to N.C. contact through the Installer Menu.
When the Photo Eye Open and Photo Eye Closed common wires are connected to this terminal, the photo eyes energize only when the motor runs. Use these terminals to preserve battery power.
Convenient 24VDC power for photo eyes or the Emergency Open input.
24 Emergency Open (Fire Dept.Open) *** N.O. input. The Emergency Open must be enabled via the Installer
Menu. It is energized by connecting to the +24V terminal above it. The
EMERG OPEN overrides photo eye & edge sensor commands.
*Do not connect an external control to the STOP or OPEN inputs unless the controls are located in clear view of the entire gate area.
**Use the RADIO OPEN input or RADIO OPTIONS spade connections for all out-of-sight controls, such as a telephone entry or radio operated controls.
***The Fire Department Open control must be keyed or guarded so that it can only be used by authorized personnel.
Revision D Smart DC Controller 4-3
Overview of the Smart DC Controller
Vehicle Detector Installation Options
The Smart DC Controller provides a feature-rich interface to four different vehicle detector inputs.
NOTE
Standard box type 11 pin (24 Volt DC or 24 Volt AC) vehicle detectors may be connected in
the traditional manner as described in Installing Standard 11-Pin Box Type Vehicle Detectors .
making field installation much faster plus providing a large performance benefit. The detector communicates with the Smart DC Controller microprocessor to achieve the following benefits over common box type detectors:
• Loop frequency is automatically set and monitored by the Smart DC Controller
• Very low power draw, which is important for maximum UPS capability during a power failure and for solar applications.
• Cross-talk between multiple loops is impossible.
• Best operating frequency for each loop is automatically selected.
• Loop frequency and call strength can be reported on the Smart DC Controller display.
• Loop malfunctions are reported and stored by the Smart DC Controller.
• Most detector or loop faults that can occur are reported and presented on the Smart DC Controller display.
It is not mandatory to use two separate detectors for inner and outer obstruction detection, but the benefits in using an additional detector provide second vehicle tailgating detection, loitering alert, and selectable nonreversing options.
Sensitivity dial adjustment Status LED
Loop wire connections
Standoff Supports
(Inset into the holes in the
Control Box.)
4-4
Front View
Figure 4-3. HY-5A Vehicle Detector Module
Rear View
SlideSmart DC Installation and Reference Manual Revision D
Overview of the Smart DC Controller
There are four vehicle detector inputs available on the Smart DC Controller:
• Free Exit Loop Detector - This opens a fully closed gate or reopens a closing gate.
• Outside Obstruction Loop Detector (Out Obs Loop) - Reversing loop on public side
• Inside Obstruction Loop Detector (In Obs Loop) - Reversing loop on secure side
• Center Loop Detector - Not used for slide gates.
NOTE
Use of any combination of HY-5A detectors and box detectors is acceptable. On occasion, multiple obstruction detectors may be mandatory. For example, an area greater than 200 square feet
(61 square meters) of loop cannot be connected to any one detector because the sensitivity becomes inadequate. Refer to
Installing Vehicle Detectors and Loops .
C
ONNECTING
HY-5A V
EHICLE
D
ETECTORS
Install the HY-5A Vehicle Detector modules according to the following procedure:
1. Turn off both AC and DC power switches.
2. Insert the locking end of the two white plastic standoffs into the mounting holes on the detector.
3. Plug the detector into the appropriate socket along the right edge of the Smart DC Controller board.
Be careful to align the six detector pins into the socket correctly (the screws for tightening the terminals should face toward the board), and then snap the standoffs into the holes in the control box.
4. Route the loop wires through the holes provided in the control box and connect the loop leads to the two terminals on the HY-5A detector. Tighten the terminal screws securely.
5. Repeat Steps 1 through 3 for each HY-5A detector.
6. To enable the detectors, turn on power. The detectors will immediately tune if they are connected to loops.
Make sure no cars or other metal objects are over the loops.
7. If the detector module is unplugged after it is enabled, a communications alert (ALERT 10) will be triggered; if the fault continues an error message, ERROR 3 “Detector Failed” is displayed.
NOTE
If there is any detector fault, the gate operator functions as if the detector is triggered.
Pressing the RESET button:
• Clears any errors
• Tunes the detectors on connected loops
• Un-installs any detectors that have been removed
8. The Smart DC Controller automatically governs frequency selection for all HY-5A detector modules. This simplifies installation and guarantees that there is no cross-talk between multiple loops. The frequency can also be manually selected; if this is required, refer to the
Table 3-2 "Smart DC Controller - Installer Menu
.
Revision D Smart DC Controller 4-5
Overview of the Smart DC Controller
9. Sensitivity is the only adjustment available on the detector itself. Generally, sensitivity does not need to be increased unless the loop is large or there are multiple loops connected to one detector.
NOTE
Do not exceed more than 200 square feet (61 square meters) of loop area to one detector.
If required, adjust the sensitivity using the rotary switch which has the following eight settings:
• 0 = Low with boost (See NOTE.)
• 1 = Normal with boost (See NOTE.)
• 2 = Medium with boost (See NOTE.)
• 3 = High with boost (See NOTE.)
• 4 = Low without boost
• 5 = Normal without boost
• 6 = Medium without boost
• 7 = High without boost
NOTE
A boost feature is applied for settings 0 through 3. Boost increases the sensitivity during a call and is useful for maintaining continuous detection if the signal becomes weak (such as with tractor-trailer trucks). Sensitivity settings 4 through 7 are the same as 0 through 3, but without the boost feature.
Table 4-2. Vehicle Detector - Configurable Functions
Display Meaning
OR 1 Outside Obstruction loop detector function
IR 1
DL 1
Inside Obstruction loop detector function
Vehicle detector logic
Installer Menu Setting Options
(Bold - Default)
0 = Pause closing only
1 = Enable reverse to open
0 = Pause closing only
1 = Enable reverse to open
1 = Standard ( Close Timer does not begin counting until all loops have cleared )
2 = Quick close (Close Timer can count to zero, even while loops are active, so the gate will close as soon as the loops are clear)
3 = Forced time out (Close Timer is forced to zero when both the OOLD & IOLD are tripped simultaneously. Additionally, all other close inputs are memorized and the gate closes immediately when all open commands and vehicle detector inputs are clear.
4 = Full Anti-tailgate (In addition to the functions of 3, the gate stops during the opening cycle when both OOLD & IOLD are tripped simultaneously. When the OOLD and IOLD loops are cleared, the gate closes immediately.
For additional information, refer to Vehicle Detector
Configuration and Quick Close Mode Selection
.
4-6 SlideSmart DC Installation and Reference Manual Revision D
Overview of the Smart DC Controller
I
NSTALLING
S
TANDARD
11-P
IN
B
OX
T
YPE
V
EHICLE
D
ETECTORS
NOTE
If photo eyes are used to monitor vehicle traffic instead of loop detectors, connect the photos eyes using the same steps. See
Installing Photoelectric Sensors For Secondary Entrapment Protection
.
If standard 11-pin box type vehicle detectors are to be used, perform the following procedure.
1. If there is sufficient space, install the sockets in the control box; if not, then install them in a separate
external housing. Figure 4-4 is for general reference only.
NOTE
Carefully consider your peripheral connections. Any peripheral device required for safe gate operation should be attached 24VDC in case of an AC power outage. Additionally, box detectors with relays require five times more power than HY-5A detectors. UPS battery life will be extended if you use HY-5A detectors instead.
2. Connect 24 Volt power to the detector. Connect Pin No. 1 to a 24VAC or 24VDC terminal and Pin No. 2 to common.
3. Connect output Pin No. 6 to the Common Bus and output Pin No. 5 to one of the four detector terminal inputs (depending upon the detector function required) on the Smart DC Controller.
4. If multiple detectors are used, route the power wires and common wire from socket to socket (daisy-
that are separate are the output wire to the Smart DC Controller and the detector loop input wires.
NOTE
Always keep the detector loop wires well twisted at all places beyond the area of the loop. The lead in portion sealed in a saw cut does not need to be twisted so long as the wires are encapsu-
lated in loop sealant and cannot move. Refer to Installing Vehicle Detectors and Loops .
Revision D Smart DC Controller 4-7
Overview of the Smart DC Controller
PIN 1
PIN 2
24VAC or 24VDC
Connect detector to match its voltage rating
Free Exit
Loop Detector
Inside
Obstrucon
Loop Detector
Outside
Obstrucon
Loop Detector
Center
Loop Detector
LOOP LOOP LOOP LOOP
Common
The center loop serves no gate function but the detector can be used as an arming loop when used in conjunction with User
Relay 22.
CENTER LOOP terminal
IN OBS LOOP terminal
OUT OBS LOOP terminal
FREE EXIT LOOP terminal
Figure 4-4. Standard 11-Pin Box Type Vehicle Detector
V
EHICLE
D
ETECTOR
C
ONFIGURATION AND
Q
UICK
C
LOSE
M
ODE
S
ELECTION
The four selectable modes are described as follows:
Mode 1 (Default)
An input from either the Free Exit, Outside Obstruction Loop, Inside Obstruction Loop or the Center
Loop will hold the gate open, reset the close timer, and block all close inputs.
Mode 2
Same function as Mode 1, except the close timer can count to zero even with the Free Exit, Outside
Obstruction Loop, Inside Obstruction Loop or the Center Loop detector inputs active. If the close timer has counted to zero, the gate will close when all detector inputs are clear.
Mode 3
Same function as Mode 1. However, the close timer is forced to zero when both the OOLD & IOLD are tripped simultaneously. Additionally, all other close inputs are memorized and the gate closes immediately when all open commands and vehicle detector inputs are clear.
Mode 4
Full anti-tailgate logic includes Mode 3 functions. In addition, the gate will stop during the opening cycle when both OOLD & IOLD are tripped simultaneously. When the OOLD & IOLD loops are cleared, the gate closes immediately. The OOLD & IOLD can be individually set so that, if tripped while closing, the gate may pause only or reverse to reopen. The free exit detector input is blocked while the gate is closing.
4-8 SlideSmart DC Installation and Reference Manual Revision D
Connecting Accessory Devices
C
ONNECTING
A
CCESSORY
D
EVICES
Entrapment Sensor Connections
Devices, such as gate edge sensors and photoelectric beams, must be installed to protect against entrapment. These secondary entrapment protection devices are required so the gate installation is in compliance with UL 325 Safety
Standards.
Figure 4-5 illustrates how to connect different sensors to the Smart DC Controller.
COMMON
TERMINALS
Access controls
(Ex. Card reader, keypad)
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
24VDC
24VDC
24VAC
24VAC
12VDC
12VDC
RS232
Mul-colored LED indicates power and gate status.
RS485 ethernet
HY-5A
FREE EXIT
HY-5A
INSIDE LOOP
HY-5A
Photo eye N.O.
connects to either
EYE OPEN or EYE CLOSE.
Photo eye
4-wire connecon:
+24V
EYE COM
Relay COM,
EYE OPEN or CLOSE -
(depending on funcon)
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
Red LED heart beat indicates processor is working.
Press buon to light acve inputs.
USER RELAY 1
Electro-mechanic al
DC
HY-5A
OUTSIDE LOOP
HY-5A
CENTER LOOP
VEHICLE LOOP
SHOW
LEDs
2 channel radio receiver
EDGE +24V OP
EN COM
RADIO OPTION
S
B COM
A
DUAL GATE
COM NO
USER RELAY 2
Solid state
USB PORT RS-485
COMMUNICATION
Connecon for a Master/Slave gate system.
Edge sensor
Revision D
Figure 4-5. Entrapment Sensor Connections
Smart DC Controller 4-9
Connecting Accessory Devices
Manual Push Button Station
A manual push button station controls the gate operator and opens, stops, and closes the gate. It is most often used by a guard in a 24-hour guard station. An example of the push button station connections on SlideSmart
!
CAUTION
Make sure the manual push button station is within site of the gate, a distance (six foot minimum) away from the gate’s moving parts, and out of reach of children.
4-10
OPEN
CLOSE
STOP
Push Buon Staon
NO
NO
NC
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
24VDC
24VDC
24VAC
24VAC
12VDC
12VDC
Figure 4-6. Manual Push Button Station Connection
SlideSmart DC Installation and Reference Manual Revision D
Connecting Accessory Devices
User Relays - Programming Procedure
The Smart DC Controller is able to interface with many types of external devices through the use of two user-
in the Installer Menu.
NOTE
The User Relays will operate normally to less than 18VDC. The USER 2 RELAY is rated for
DC only up to 48V and does not have a N.C. (normally closed) connection.
Use the Smart DC Controller buttons to program the user relays according to the following steps:
1. Select and connect to the relay you wish to use on the Smart DC Controller board.
2. Access the Installer Menu and RL 1 or RL 2 display (depending on the relay you have connected).
3. Enter the appropriate function using the associated number (1 through 24) listed in the table.
Table 4-3. User-Programmable User Relays - Function Options
9
10
11
No.
Name
1
2
3
4
5
6
7
8
12
Description
Close limit output
Close limit pulse output
Open limit output
Open limit pulse output
Warn before/during operate output
Gate Lock output
Gate forced open output
Gate open too long output
Creates an interlock signal to another operator’s interlock input, or simply to indicate that the gate is secure. The relay is released when the fully-closed limit switch is tripped. The relay is energized when the fully-closed limit is released. (Any open command energizes the relay.)
Used in a sequenced system to command a second machine to close. Generates a brief pulsed output that occurs when the close limit is triggered.
Indicates a full-open position. This output becomes active when an open-limit is triggered and releases when the open-limit is released.
Trips a sequenced barrier arm gate operator to open. Generates a brief pulsed-output when the open-limit is triggered. An additional pulse is also generated with any new open command even when the gate is already fully-opened.
Controls an external warning device. This output operates at the same time as the internal warn before operate buzzer.
Controls external solenoid locks or magnetic locks. In both directions of travel, this output is activated about 7/10 ths
of a second before the operator starts moving the gate and remains active while moving as well as for a few seconds after stopping.
Activated if the gate is forced off the closed limit switch and operator is not able to restore the gate to full closed within four seconds. This alarm resets itself in 30 seconds.
Activates when the gate is open longer than a user-selected period of time. Adjustable from 0 delay to 135 seconds delay in 30-second time increments.
Note: TL - OPEN TIME ALERT adjustments can be made in the Installer Menu.
Safety Mode Alert output Activated when system is in Safe Mode or entrapment mode.
Entrapment Mode Alert output Activated only when system is in the Entrapment Mode.
Unauthorized Vehicle Entry output
Outside Obstruction Vehicle
Detector output
Activated when a second vehicle enters from the outside without a valid input from an access control device. This output releases when an access control input signals open or the gate reaches the close limit position.
Interlocks an entry device to prevent pedestrian use. This output is active whenever the
Outside Obstruction Loop Detector is tripped.
Revision D Smart DC Controller 4-11
Connecting Accessory Devices
Table 4-3. User-Programmable User Relays - Function Options (Continued)
16
17
18
No.
13
14
15
19
20
21
22
23
24
25
Name
Loitering Alert
Gate nearing full travel output
Gate Failure output
Motor Running output
AC Power Failure output
DC Power Failure output
Flasher Relay
Description
Indicates a vehicle is loitering on the Outside Obstruction Loop. Adjustable from 0 delay to
135 seconds delay in 30-second time intervals.
Note: LT - LOITERING ALERT adjustments can be made in the Installer Menu.
Activated when the gate is three feet from full travel in both the open and close directions.
This output is used to reduce the sensitivity of a proximity sensor near the ends of gate travel.
Activated to report occurrence of a problem. Indicates the system is in an Error Mode, Fault
Mode or Entrapment Mode. If active, the gate is disabled.
Active when the motor is running and the gate is in motion.
This relay is normally energized and drops with loss of AC power.
Activated when the battery power is very low, but the output ceases when the battery is dead.
The relay is triggered when the battery is less than 20 Volts.
Controls flashing lights that pulse once per second. The relay is constantly activating except when the open limit switch is triggered.
Active whenever the Exit Loop is tripped.
Free Exit Loop Vehicle Detector output
Inside Obstruction Vehicle
Detector output
Center Loop Detector output
Activated when the Inside Obstruction Vehicle Detector is tripped.
Activated when the center loop detector is tripped. Since this input is not used for a sliding gate, User Relay 22 can be used in combination with a detector to perform the function of an arming loop detector because there is no associated gate control logic.
Not used in the Smart DC Controller External Latching Gate Lock
Output
Gate at Partial Open Position
DC Power Alert
Active when the partial open position is reached or exceeded.
Deactivates when the software detects a low battery voltage (below 21VDC, but greater than
18VDC) for a duration of 2 seconds or more. To slow battery drain, accessory power loads are shed. Connect wiring to Relay 2, and then program the Installer Menu item Relay 2 Logic by entering the number 25 in its data field.
4-12 SlideSmart DC Installation and Reference Manual Revision D
Power Requirements
Bi-parting Gate Systems
Chapter 5
Configuring two operators to be a Master and Slave pair is easy with the Smart DC Controller. There is no need to order a special model or any adapters. The area of the board marked Dual Gate employs a 3-wire
RS-485 serial port for communication between master and slave operators. See Figure 5-1.
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
EDGE +24V OP
EN COM
RADIO OPTION
S
B COM A
DUAL GATE
Connection for Master/Slave pair
Figure 5-1.
USB Port
P
OWER
R
EQUIREMENTS
When installing a dual-operator system, the following must be adhered to:
• An electrical conduit for interconnecting wires must span between the two operators. The master-slave communication wires and any low voltage control wires must be installed in a conduit that is separate from
the high voltage power wires. See Figure 5-2.
• Complete the installation of both operators as separate machines and verify that their basic functions are correct as solo operators before interconnecting them.
• External control inputs, vehicle detectors and entrapment protection sensors may be connected to either gate operator without regard to preference.
• Be sure both operators are running the same software version. The software version is available on the display by pressing the RESET button on the operator. The software version appears beneath the word
HYSECURITY. Keep the most current software loaded. It is available at www.hysecurity.com. Make it part of your maintenance routine to check for software upgrades on a regular basis.
• Both operators can be connected to the same 20A circuit breaker in the main panel. The wire size affects operator performance. Use the following chart as a guideline to size wire for the given distance from the power source to BOTH operators.
AC Power - Dual Operators
115V
230V
14 gauge wire
460 ft (140 meters)
1465 ft (446 meters)
12 gauge wire
750 ft (228 meters)
2350 ft (716 meters)
10 gauge wire
1160 ft (354 meters)
3750 ft (1143 meters)
Revision D Bi-parting Gate Systems 5-1
Master and Slave Wiring Connections
M
ASTER AND
S
LAVE
W
IRING
C
ONNECTIONS
Master Slave
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
USER 1
DC
EDGE +24V OP
EN COM
RADIO OPTIONS
B COM
A
DUAL GATE
COM NO
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
USER 1
DC
EDGE +24V OP
EN COM
RADIO OPTIONS
B COM
A
DUAL GATE
COM NO
5-2
Shielded cable
(3-wire) Conduit (in the ground) Ground
Shield wire
Note: Do not connect the ground shield wire at both ends.
Figure 5-2.
1. As shown in Figure 5-2, connect a shielded communications cable to the DUAL GATE inputs in each
unit. The inputs are located near the base of the Smart DC Controller. Be sure to connect the wires in pairs
to the same terminal ports (A-A, B-B, and COM to COM) on both units. See Table 5-1.
Table 5-1.
Slave
A
COM
B
Shield wire to Ground*
Master
A
COM
B
* Only ground to one unit. Do NOT attach the shield wire to both units.
2. Attach a ring terminal to the shield wire and connect it to the Smart DC Controller’s convenient ground
NOTE
Connect the ground shield wire to only one operator, not both.
SlideSmart DC Installation and Reference Manual Revision D
Master and Slave Menu Setup
M
ASTER AND
S
LAVE
M
ENU
S
ETUP
Determine which unit will be set up as the Master. The other unit will be set up as the Slave. It doesn’t matter which unit is which, but you must identify the Master and Slave operators by taking the following steps:
Start by configuring the MASTER unit.
1. At a gate status display, press the MENU button twice. This accesses the User Menu and the
CLOSE TIMER display appears.
2. Simultaneously, press the OPEN and RESET buttons to enter the Installer Menu. Release the buttons and the LEARN LIMITS display appears which is the first item in the Installer
Menu.
PREV
HYSECURITY
GATE CLOSED
OPEN CLOSE STOP
NEXT SELECT
MENU RESET
1. Start at a gate status display.
3. Press NEXT until the DUAL GATE display appears. The factory default setting is 0.
4. Use the SELECT and NEXT buttons to navigate and change the setting to 2 MASTER.
CT 0 (OFF)
CLOSE TIMER
2. Access the User
Menu by pressing
MENU twice.
5. To exit the Installer Menu, press the MENU button. A gate status appears in the display indicating you have returned to Run Mode.
OPEN CLOSE STOP MENU RESET
Note: For proper operation, you must set the other gate operator as SLAVE.
6. Move to the other SlideSmart operator.
PREV NEXT SELECT
7. Using the buttons on the Smart DC Controller, access the DUAL GATE display through the
Installer Menu.
8. Perform the same steps, 1 through 5, but address the operator as SLAVE, setting 1.
LL 0 (OFF)
LEARN LIMIT
OPEN CLOSE STOP MENU RESET
3. Access the Installer
Menu, by simultaneously pressing OPEN and
RESET. Release the buttons.
When the SlideSmart operator has been designated as the master and the other as slave, the dual-gate operators will be in constant communication, most often, in a peer-to-peer relationship. For example,
• Any control input that is attached to the slave unit will be recognized by the master once the Installer
Menu is properly configured in both units.
PREV NEXT SELECT
DG 2 (MASTER)
DUAL GATE
4. Use NEXT to navigate to the menu display. Change the setting using the
SELECT and NEXT buttons.
• A diagnostics log is maintained in each unit, but both units run and store the errors codes and diagnostics pertinent to each other.
OPEN CLOSE STOP
PREV NEXT SELECT
MENU RESET
• The master unit controls the close timer even if the timer is set in the slave unit. If a close timer is set in both units, the master unit overrides the slave setting.
NOTE
If the dual-gate communication stops for whatever reason, (communication wire severed or the power switch is turned off in one unit), both operators cease to function and an ERROR 4
(Master/Slave Communication Error) appears in the display.
Revision D Bi-parting Gate Systems 5-3
Master and Slave Menu Setup
This page intentionally blank.
5-4 SlideSmart DC Installation and Reference Manual Revision D
Connecting a Radio Receiver for Remote Open
Reference
Chapter 6
This section of the manual provides information which may be useful when installing SlideSmart operators.
It includes how to:
• Connect a Radio Receiver for Remote Open
• Install a Gate Locking Mechanism
• Install Vehicle Detectors and Loops
• Install Photoelectric Sensors
• Install Gate Edge Sensors
• Troubleshoot error codes, faults, and hardware issues
• Diagnose vehicle detector and loop faults
• Handle General Maintenance issues
C
ONNECTING A
R
ADIO
R
ECEIVER FOR
R
EMOTE
O
PEN
Take the following steps to mount a commercial style 24VDC radio receiver (external antenna type):
1. Install the receiver in the channel of the chassis on either side of the control box.
2. Knock out the closest hole in the bottom of the control box and route the wires to the area marked RADIO OPTIONS. Only three wire connections are needed because the common wire and one radio output wire
are connected together. Figure 6-1 shows
additional wires from a two channel receiver.
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
DC
EDGE +24V OP
EN COM
RADIO OPTIONS
B COM
A
DUAL GATE
COM NO
Shows connecons for Remote Open and Gate Edge (dashed line).
R2
R1
Power
3. Make sure to observe polarity and crimp together the black radio common wire and one of the radio output wires using a ¼-inch spade connector.
Two Channel Radio Receiver
Figure 6-1.
4. Fasten the two crimped wires to the COM terminal.
5. Connect the red wire to the +24V spade and connect the other radio output contact wire to the spade marked OPEN.
Note: This terminal is the same as the input terminal labeled RADIO OPEN along the left edge of the Smart
DC Controller.
Revision D Reference 6-1
Installing a MagLock or Solenoid Lock
6. Mount an external antenna onto the top of a fixed fence post near the operator.
7. Connect the antenna into the socket on the radio receiver.
8. Set the “DIP” switches in the receiver to match the same code used in the transmitter.
NOTE
If an edge sensor transmitter is also used to reverse the gate, be certain to use a two channel commercial receiver. The edge and hand held transmitters must have their codes set to match the receiver or they will not function.
I
NSTALLING A
M
AG
L
OCK OR
S
OLENOID
L
OCK
To provide additional gate security, a maglock or a solenoid lock can be used and connected to the Smart DC
Controller. The Smart DC Controller releases the lock prior to initiating gate movement. Before installing the lock, be sure to:
• Determine the electrical power requirements of your lock (maglock or solenoid lock). Electronic board and peripheral connections differ between high voltage and lower voltage gate operators.
• Determine the current required. A total combined current draw of 1 amp is available from the 24VDC,
24VAC, or 12VDC power supply. If the peripherals attached to the terminals need more than 1 amp, a separate
power supply is required. Refer to Overview of the Smart DC Controller and Figure 4-2.
6-2 SlideSmart DC Installation and Reference Manual Revision D
Installing a MagLock or Solenoid Lock
Installing a Lock for 12VDC or 24VDC Systems
To install a lock for 12VDC or 24VDC systems, take the following steps:
1. Connect a wire between COM on
USER 1 RELAY and a COM terminal on the Smart DC Controller board. See
2. Connect the power lead from the lock to the appropriate power spade
(+24VDC or +12VDC)
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
3. Connect the common wire from the lock to NC on USER 1 RELAY.
Note: Connect to NO on USER 1
RELAY if installing a Solenoid lock.
4. Set the User Relay function in the
Installer Menu to RL1 - 6. Refer to
Setting the User Relay Function in the
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
24VDC
24VDC
24VAC
24VAC
12VDC
12VDC 2
Aach the power wire from the lock to the appropriate power spade.
Connect COM on board to COM on USER 1 RELAY.
1
USER 1 RELAY
COM
NO NC
3
DC
COM NO
Connect the COM wire from the lock.
A Solenoid lock aaches to NO.
A MagLock aaches to NC.
Figure 6-2.
Revision D Reference 6-3
Installing a MagLock or Solenoid Lock
Installing a Lock on 24VAC Systems
To install a lock for 24VAC systems, take the following steps:
1. Connect a wire from COM on USER
1 RELAY and one 24VAC power
2. Connect a power lead from the lock to the remaining 24VAC power spade.
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
24VDC
24VDC
24VAC
24VAC
12VDC
12VDC
2
3. Connect the remaining power lead from the lock to the NC terminal on
USER 1 RELAY.
Note: Connect to NO on USER 1
RELAY if installing a Solenoid lock.
4. Set the User Relay function in the
Installer Menu to RL1 - 6. Refer to
Setting the User Relay Function in the
Installing a Lock for
High Voltage
Systems
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
Aach the power lead from the lock to the 24VAC power spade.
USER 1 RELAY
Connect from COM on
USER 1 RELAY to 24VAC.
1
COM
NO NC
3
DC
COM NO
Connect the power lead from the lock’s coil to:
NC for a MagLock
NO for a Solenoid lock
Figure 6-3.
To install a lock on higher voltage systems (115V or
230V), take the following steps:
1. Connect one lead of the power supply to one lead
of the lock’s coil. See Figure 6-4.
115VAC
230VAC
POWER SUPPLY
1
Lock
High voltage
2. Connect the other lead of the lock’s coil to NO on
USER 1 RELAY.
Note: Connect to NC on USER 1 RELAY if installing a maglock.
3. Connect the COM on USER 1 RELAY to the second lead wire in the power supply (115V or
230V).
High voltage
3
2
NO
COM
USER 1 RELAY
Figure 6-4.
4. Set the User Relay function in the Installer Menu to RL1 - 6. Refer to
Setting the User Relay Function in the Installer Menu .
6-4 SlideSmart DC Installation and Reference Manual Revision D
Installing a MagLock or Solenoid Lock
Setting the User Relay Function in the
Installer Menu
5. Enter the Installer Menu and set the User 1
Relay to Function 6 - GATE LOCK OUTPUT.
HYSECURITY
GATE CLOSED
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
1. Start at a gate status display.
CT 0 (OFF)
CLOSE TIMER
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
2. To access the User
Menu, press MENU twice.
LL 0 (OFF)
LEARN LIMIT
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
3. To access the
Installer Menu, simultaneously, press
OPEN and RESET
RL 6
GATE LOCK OUTPUT
OPEN CLOSE STOP MENU RESET
PREV NEXT SELECT
4. Use NEXT to navigate to the menu display. Change the setting using the
SELECT and NEXT buttons.
Revision D Reference 6-5
Installing Vehicle Detectors and Loops
I
NSTALLING
V
EHICLE
D
ETECTORS AND
L
OOPS
A vehicle detector passes a small current flow through the “loop” which then becomes an inductive coil. When a vehicle passes over the loop, the detector senses the resultant drop in the inductance and actuates the detector output.
Loop Configurations:
Configurations differ depending on the application. In parking applications, a loop may be as small as
4 x 6 foot (122 x 183cm). In traffic applications employing one of our swing or slide gate operators, the smallest loop should not be less than 6 x 6 foot (183 x 183cm) in order to detect high bed vehicles.
Rules to Follow for Security Gate Applications:
The side of the loop closest to the gate must be located at least 4 ft from the line of travel.
1. The shortest side of the loop should be between 6 and 8 feet (1.8m and 2.4m) in length. The longest side of the loop should be between 6 and 20 feet (1.8m and 6.1m) in length. For applications that need to span a wide area, use several smaller loops. Do not connect more than 200 square feet (18.6sq. m) of loop area to a single detector.
2. In applications with multiple loops, keep each loop at least 6 feet (1.8m) apart. This avoids “cross talk”. It is possible to have loops closer together by selecting different frequencies. An advantage of using
HySecurity model HY-5A detectors is that problematic “cross talk” is not possible.
3. For greater sensitivity and less chance of false calls caused by the motion of the gate, it is better to use multiple smaller loops, connected in a series circuit, to one detector instead of a single large loop.
4. To avoid interference, keep loops at least 2-inches (5cm) above any reinforcing steel. Do not route loop wires with, or in close proximity to, any other conductors, including other loop leads, unless shielded leadin cable is used. Never route high voltage circuits in PVC conduit near a loop.
5. Loop and lead-in wire should be one continuous piece. Avoid splices, if possible. If a splice is necessary for any reason, “pot” the splice in epoxy or use heat shrink to ensure that the quality of the splice covering is the same as the original wire jacket.
6. Use only 14, 16, or 18 gauge stranded wire with a direct burial jacket. Cross linked polyethylene insulation types, such as, XLPE or XHHW, will last much longer and are less prone to damage during installation than conventional insulation types. Preformed loops can be used before road surfacing or under pavers.
7. Twist loose tails of lead-in wires tightly, approximately ten times per foot. See Figure 6-5.
8. Follow this guide for the correct number of turns in the loop;
12 to 20 sq. ft = 5 turns; 20 to 60 sq. ft. = 4 turns; 60 to 240 sq. ft. = 3 turns
3.7 to 6.1sq. m = 5 turns; 6.1 to 18.3 sq. m = 4 turns; 18.3 to 73.1sq. m = 3 turns
Twist Like This Twist lead-in at least 10 turns per foot
6-6
Like This Not Like This
Figure 6-5.
SlideSmart DC Installation and Reference Manual Revision D
Installing Vehicle Detectors and Loops
9. This guide is written from a design perspective, but installation workmanship practices are equally important to insure proper operation and long loop life. The best way to insure a quality installation is to employ a professional installer experienced with detector loops. A few important practices are:
• The slot in the surface of the road should be cut ¼-inch wide x 1½-inch deep (6.3mm x 38.1mm).
• The corners of the cut must be at an angle or core drilled to relieve stress on the wires.
• After the wire is installed, the slot must be completely backfilled with a non-hardening sealer. If the loop wires are able to move in the slot after the sealer has set, the detector may give false calls.
Figure 6-6.
Detector Logic
HySecurity recommends that vehicle detectors be used for free open and obstruction sensing logic only.
Because of their slower speeds, closing logic is a poor choice for security gate systems. Since there are several ways that the gate may be left standing open and because there is a loss of safety, our circuit has not been designed to accommodate “detect to close” logic.
Loop Diagnostics
The following tests cannot guarantee a functioning loop, but failure of either test means that the loop is definitely suspect, even though it may still be functioning at the time.
1. Test the resistance of the loop and lead-in wire. It should not exceed 4 Ohms.
2. Test the resistance between the loop and earth ground with a 500V Megohm meter. It should be 100
Megohms or more. Loops may function at 100 Megohms or less but will not be reliable (e.g. when the ground is wet from rainfall). Low resistance indicates broken or moisture saturated insulation. This is common if inappropriate wire insulation has been used.
A schematic for a slide gate loop layout is shown in Figure 6-7.
Revision D Reference 6-7
Installing Vehicle Detectors and Loops
This layout illustrates a bi-direconal traffic system with controlled access entry (card reader, radio control, etc.) and a free exit gate. The gate’s closure me is determined by the number of seconds entered in the
CLOSE TIMER display found in the
User Menu. The ming to close starts when all loops are clear.
The mer is adjustable from
1 to 99 seconds.
ENTER
PUBLIC SIDE
EXIT
C
OBSTRUCTION
LOOP
A
B
ACCESS CONTROL DEVICE
(Card reader, etc.)
D
OBSTRUCTION
LOOP
E
DIMENSIONS
A = 6 to 20 (2 to 6m)
B = 6 to 8 (2m to 243cm)
C = Maintain 4 (122cm)
D = Maintain 5 (152cm) between loop and edge of roadway. No vehicle can pass through such a small area and escape detecon.
E = Located for convenience of use.
FREE EXIT or
OBSTRUCTION
LOOP
SECURE SIDE
Vehicle Detectors and Loop Layout for Slide Gates
Figure 6-7.
6-8 SlideSmart DC Installation and Reference Manual Revision D
Installing Photoelectric Sensors For Secondary Entrapment Protection Only
I
NSTALLING
P
HOTOELECTRIC
S
ENSORS
F
OR
S
ECONDARY
E
NTRAPMENT
P
ROTECTION
O
NLY
Public Side
Le Hand Ga opening te
Photo eye
Secure Side
Photo eyes
Photo eye
Figure 6-8.
entrapment protection devices. If no other secondary external entrapment protection devices (like edge sensors) are installed, then at least two photoelectric sensors are required to guard the gate in each direction of travel. If the photo eyes are tripped, the operator will temporarily stop the gate.
Consult a photoelectric sensor manual for wiring details. Make all electrical connections to Smart DC
Controller as shown in Figure 6-9.
O
PERATION
N
OTES
:
• A photo eye trip does not reverse gate.
• The Smart DC Controller software is factory set to stop upon photo eye trip.
• Software is configurable to stop and reverse two seconds upon photo eye trip.
• If the photo eye is cleared within five seconds, the gate will proceed in the direction of travel.
The Smart DC Controller has two photoelectric sensor inputs (EYE OPEN and EYE CLOSE). See
protection device, must be tested to, and recognized by, the UL 325 Standard.
Revision D Reference 6-9
Installing Photoelectric Sensors For Secondary Entrapment Protection Only
There are two common types of photoelectric sensors, thru-beam and retro-reflective, and each has its advantages.
• A thru-beam sensor is generally more powerful and able to function reliably with dirty optics and in poor weather.
• A retro-reflective sensor does not require the installation and extra wiring of a separate emitter and receiver as is required in a thrubeam system, but retro-reflective eyes are generally more problematic in poor weather.
Avoid using retro-reflective devices across outdoor distances greater than 24 feet (7.3m) because of performance and reliability issues.
Photo Eye Open
Direction
Photo Eye Close
Direction
Photo Eye COM terminal
Photo Eye +24 VDC
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
Mount thru-beam type photo eyes approximately
15" to 30" (4.6 to 9m) above the ground and as close to the gate as possible. A minimum of two photo eyes are required, one photo eye to guard the open direction and the other for the close direction of travel, unless gate edges for entrapment protection are installed. Mount the emitters and the receivers just beyond the travel of the gate in both the full open and full closed positions of travel. The installation locations described above are intended for pedestrian detection. If photo eyes are to be used for vehicular detection, install a low elevation photo eye for cars and another photo eye at a height of about 55" (140cm) to detect semi-trucks.
EDGE +24V O
RADIO
Figure 6-9. Connections for Entrapment
Protection only
Note: EYE COM & +24V is the recommended way to connect standard photo eyes to Smart DC Controller.
Other options include:
• Photo eye ON continuously: COM & +24VDC or +24VAC (if the photo eye uses 24VAC).
• Photo eye ON continuously with anti-fog feature:
COM & +24VAC (connecting to DC will negatively affect battery charging).
• Photo eye and peripherals draw more than 1A off one power supply: Requires a separate power supply connected to the service outlet.
NOTE
If photo eyes are to be used for vehicle detection and logically function the same as a vehicle detector, connect the common wires to the COM terminals on the left side of the board and wire the NO output contact to the appropriate vehicle detector input: EXIT LOOP, IN OBS
LOOP, and OUT OBS LOOP.
If the photo eye has an internal switch for setting Light Operate vs. Dark Operate, select Light Operate. If the photo eye has a relay output and has both NO and NC terminals, some experimentation may be required to determine the proper connection. This is because, in the Light Operate mode, the output relay is normally energized and releases when the beam is blocked. Some manufacturers label an output as NO, when it is actually an NC contact. If the photo eye has a solid-state output you must choose a sinking type connection.
Three wires to the receiver and two wires to the emitter are all that is required.
• Depending on how the photo eyes are to be wired, +24VAC, +24VDC, or +12VDC, power is provided via spades located just to the right of the COM terminal strip near the left side of the board.
• The receiver and emitter common wires are connected to the EYE COM terminal at the bottom, left of the Smart DC Controller. (See NOTE.)
6-10 SlideSmart DC Installation and Reference Manual Revision D
Installing Photoelectric Sensors For Secondary Entrapment Protection Only
• The photo eye NO or NC output wires connect to the Smart DC Controller at the EYE CLOSE terminal if the photo eye spans the road, or at the EYE OPEN terminal if the photo eye spans the area between an open gate and a wall or other structure. (See NOTE).
S
UPERVISED
C
ONNECTION
:
NOTE
This connection REQUIRES that both the Eye Open and Eye Closed inputs be connected to photoelectric eyes.
If two photo eyes are being installed and both have true NC output (one that is NC when the photo eye is powered, aligned and set for Light Operate), then a supervised connection is recommended. A supervised connection will signal a system Fault and prevent gate operation if either the open or close photo eye connection ever becomes an open circuit or a short circuit. The Installer Menu item PC - Photo Eye Output must be changed from a 0 to a 1 to enable this feature.
P
HOTO
E
YE
F
UNCTION
:
A tripped photo eye will prevent the gate from starting in either direction if the gate is stationary. If tripped while in motion, the standard function is to stop the gate motion and then automatically restart again if the photo eye is clear within five seconds. An optional setting in the Installer Menu will cause a two second reversal of travel.
Alignment:
Most photo eyes require careful optical alignment in order to aim the emitter beam to the center of the receiver or reflector. In order to avoid false triggering, it is important to carefully align the system, especially with retroreflective photo eyes. The best way to assure true centering of the beam is with some trial testing where the emitter is shifted to move the beam left and right and up and down until the range of the invisible cone of the infrared beam is known. Photo eyes usually provide alignment aid LED's for this setup, but they can be hard to see. HySecurity has provided a unique feature that turns power on to the photo eyes and causes our buzzer to
chirp when the photo eyes enter and exit alignment. See Table 3-1 "Smart DC Controller - User Menu
to enable this feature. Set the menu item PE - PHOTO EYE ALIGN from a 0 to a 1.
The buzzer chirps once when the emitter and photo eye receiver are not aligned. When the emitter and receiver are aligned, the buzzer chirps twice. If they go out of alignment again, the buzzer will chirp once. This
“alignment mode” will automatically reset to 0 the next time the Close Limit Switch is triggered or the RESET key is pressed.
Notes about retro-reflective systems:
Correct installation and alignment of a retro-reflective photo eye and its reflector is important for trouble free performance. Any system operating at a range greater than 16 feet is more prone to false triggering due to dirty optics, condensation or poor weather. If care is taken in the initial mounting and alignment of the 3-inch reflector, the chance of problems is greatly reduced. Use only through beam photo eyes for a distances greater than 24 feet because the function of a retro-reflective photo eye will be too unreliable.
Taking steps to protect the photo eye and the reflector from being exposed to fog and being absolutely certain the photo eye is perfectly aligned will greatly reduce any false triggering of the system. The ideal mounting of a retro-reflective photo eye is inside an enclosure.
Revision D Reference 6-11
Using Photoelectric Sensors Instead of Vehicle Loops
The ideal reflector mounting suspends it inside a 12-inch long piece of 3-inch PVC conduit. Cut the opening of the PVC conduit at a 45-degree angle to act as a drip shield. Hold the reflector against the backside of the
PVC conduit by attaching a 3-inch male connector. Do not cement the connector. This would prevent the reflector from being reached for future cleaning. To create a mounting base, attach a 3-inch aluminum flange
(electric meter hub) to the connector. This whole package can be mounted to any flat surface.
Locate the reflector in the center of the invisible beam of infrared light to achieve the most sensitive alignment.
The beam center is determined by the following test: while holding the reflector in your hand, slowly raise it until the beam is no longer returned and the photo eye trips. Mark this maximum height. Now lower your hand and determine the lower limit of the infrared beam by watching for the trip point. Mark this position as well. Repeat the same procedure for left and right at the center elevation of the beam, as determined by the previous test. Once the four limits have been determined, either mount the reflector in the center of the area outlined or realign the eye for the position of the reflector. If the photo eye is realigned, be sure to perform the centering test again to verify that the reflector is truly in the center.
U
SING
P
HOTOELECTRIC
S
ENSORS
I
NSTEAD OF
V
EHICLE
L
OOPS
Some site conditions (for example, dirt or gravel roads) may warrant using photoelectric sensors as vehicle
detectors. Refer to Figure 6-11.
, but connect the photo eyes to the Smart Touch DC Controller loop detector inputs. See
Photo Eye connections for
Free Exit detectors
Photo Eye connections for
Inside Obstruction detectors
Photo Eye connections for
Outside Obstruction detectors
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
EDGE +24V O
RADIO
Figure 6-10. Connections for Loop Detectors
6-12 SlideSmart DC Installation and Reference Manual Revision D
This layout illustrates a bi-direconal traffic system with controlled access entry (card reader, radio control, etc.) and photo eyes used as vehicle detectors. The gate’s closure me is determined by the number of seconds entered in the
CLOSE TIMER display found in the
User Menu. The close mer starts when all photo eyes are clear. The mer is adjustable from 1 to 99 seconds.
Using Photoelectric Sensors Instead of Vehicle Loops
PUBLIC SIDE
ENTER
OUTSIDE OBSTRUCTION
EXIT
ACCESS CONTROL DEVICE
(Card reader, etc.)
1 Placement of photo eyes if used as vehicle detectors.
B
A
Placement of photo eyes for entrapment protecon
C
INSIDE OBSTRUCTION
2 Placement of photo eyes if used as vehicle detectors.
D
FREE EXIT
DIMENSIONS
A = width of roadway*
*Reflecve photo eyes can only be used if “A” is less than 24 (7.3m)
Select appropriate distances between B, C, and D to make sure vehicles remain detected within the photo eye zones.
SECURE SIDE
Figure 6-11. Photo Eye Placement when used as Vehicle Detectors
3 Placement of photo eyes if used as vehicle detectors.
Revision D Reference 6-13
Installing Gate Edge Sensors
I
NSTALLING
G
ATE
E
DGE
S
ENSORS
Photo eye
Upright post edge
Wall or fence edge
Gate edge
Photo eye
Figure 6-12.
sliding gates, one or more contact sensors (edge sensors) must be located at the leading edge, trailing edge and post-mounted both inside and outside of the sliding gate. Three-sided detectors are ideal for slide gates. If the clearance of the gate is 6" (15cm) or more above the road, then an edge sensor must be mounted on the bottom edge. Underwriters Laboratories requires that any contact sensor used as an external entrapment protection device, must be laboratory tested to, and recognized by, the UL 325 Standard.
Drill holes through the edge's mounting channel and through the surface that each gate edge is to be mounted.
Securely fasten every edge sensor. Make sure sensors extend to within 6" (15cm) of the pavement on the leading edge of the gate.
6-14 SlideSmart DC Installation and Reference Manual Revision D
Installing Gate Edge Sensors
Edge sensors that are not attached to the moving gate, such as post mounted sensors, must be wired in parallel and directly connected to the gate operator:
• If the gate is sliding open to a wall with less than 16" (41cm) of clearance, mount an edge sensor to the wall that aligns with the gate when it is in the open position.
Always route the leads from the edge sensors to the gate operator so that they are protected from physical damage.
• The preferred receiver connections are
shown in Figure 6-13. An optional
method is to connect one edge sensor lead to a COM terminal at the top, left side of the Smart DC Controller, and the other lead to the EDGE terminal, at the bottom, left side of the controller.
Edge Sensor
Edge Sensor
COM
COM
STOP
OPEN
CLOSE
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
USER 1
DC
EDGE +24V OP
EN COM
RADIO OPTION
S
B COM
A
DUAL GATE
COM NO
Shows connecons for Gate Edge and
Remote Open.
R2
R1
Edge sensors may be used with an edge transmitter and a receiver in order to transmit to the gate operator. The use of retractable cord reels or curl cords is not recommended because of durability problems with these devices in outdoor environments.
Power
Two Channel Radio Receiver
Figure 6-13.
• Mount gate edge sensors to the leading edge and bottom edge of the gate so that entrapment protection is provided in both directions of travel.
• Mount one or two edge transmitters onto the gate panel near the upper corner of the leading edge of the gate. All edge sensors will function correctly if only one transmitter is used, but wiring multiple edges to a single transmitter may be impractical or displeasing visually.
• Connect the edges to the terminals in the edge transmitter and set the “dip” switches of the transmitter to
match the setting in the receiver to be used. Refer to Figure 6-13.
Revision D Reference 6-15
Smart DC Controller Troubleshooting
Mount a commercial style radio receiver* (external antenna type) in the channel of the chassis on either side of the operator. Knock out the nearest hole in the bottom of the control box, and route the wires to the area labeled RADIO OPTIONS. Only three wire connections are needed because the common wire and one radio output wire connect to the same terminal. Being certain to observe polarity, crimp together the black radio common wire and one of the radio output wires using a 0.25-inch spade connector, and fasten the wires to the
COM terminal. Connect the red wire to the +24V terminal and connect the other radio output contact wire to the spade marked EDGE (this is the same as the EDGE input on the terminal strip near the left side of the board).
• Mount an external antenna onto the top of a fixed post of the fence near the operator.
• Connect the antenna into the socket on the radio receiver.
• Set the “DIP” switches in the receiver to match the same code used in the transmitter.
Test the operation of the reversing edge to make sure that it functions correctly. Advise the gate user that they must retest this vital function weekly.
* If there is also to be a radio receiver for a hand held transmitter to operate the gate, be certain to use a two channel commercial receiver. The edge and hand held transmitters must have their codes set to match the receiver or they will not function.
S
MART
DC C
ONTROLLER
T
ROUBLESHOOTING
This section is available to help you troubleshoot any problems that may occur with the SlideSmart operator. It provides information about the Smart DC Controller display codes.
The Smart DC Controller system includes many self diagnostics. Specific messages appear on the LCD and the
Audio Alert buzzer sounds distinctive chirps. Any alerts, faults or errors are also logged into memory and date/ time stamped. For diagnostic purposes these messages can be retrieved with optional START software available from HySecurity. Refer to
Smart Touch Analyze and Retrieve Tool
.
DC Controller display.
6-16 SlideSmart DC Installation and Reference Manual Revision D
Smart DC Controller Troubleshooting
Revision D Reference 6-17
Smart DC Controller Troubleshooting
6-18 SlideSmart DC Installation and Reference Manual Revision D
Smart DC Controller Troubleshooting
Revision D Reference 6-19
Smart DC Controller Troubleshooting
6-20 SlideSmart DC Installation and Reference Manual Revision D
Smart DC Controller Troubleshooting
Revision D Reference 6-21
Smart DC Controller Troubleshooting
6-22 SlideSmart DC Installation and Reference Manual Revision D
Smart DC Controller Troubleshooting
Vehicle Detector and Loop Fault Diagnostics
If HySecurity HY-5A vehicle detector modules are used, the Smart DC Controller has the ability to store and report detector and loop fault information for performance diagnostics.
If the Smart DC Controller senses a loop or detector problem:
• The LCD display flashes the name of the affected detector or error and the appropriate alert code.
• The buzzer chirps continuously at regular intervals until the issue is resolved.
Table 6-2 HY-5A Vehicle Detector Faults and Errors
Alert or Error
ALERT 7
ALERT 8
ALERT 9
ALERT 10
ALERT 11
ALERT 12
FREQ SHIFT FAULT
LOOP SHORTENED
LOOP OPEN
I
2
C BUS ERROR
DETECTOR FAULT
ON TOO LONG
Advisory
HY-5A vehicle detector -
Abnormal frequency change alert.
HY-5A vehicle detector -
Loop is shorted.
HY-5A vehicle detector -
Disconnected loop alert.
HY-5A vehicle detector -
Communications alert.
HY-5A vehicle detector -
Malfunction alert.
Detector input triggered too long -
More than five minutes.
Resolution
The alert indicates an unstable loop frequency. Check the loop and lead in wires for problems. Replace them, if necessary.
The alert indicates that the loop and lead in wires are shorting out. check the wires for problems. Replace them, if necessary.
The alert indicates the loop wires are loose or disconnected. Check the wires for problems. Replace them, if necessary.
The alert indicates the detector is not communicating properly with the Smart
DC Controller. The alert occurs if the detector is unplugged or the connection is unstable. If communication is not reestablished within 30 seconds, the controller will reset and the message changes to
ERROR 3.
The display indicates the HY-5A detector malfunction. Check detector for problems.
Replace it, if necessary.
The display indicates the HY-5A detector malfunction. It alert also works for any input connected to the terminal strip for standard box detectors. Check that a vehicle is not parked on the loop. Also, determine if the loop is stable. An unstable loop can hold the detector in a triggered state.
ERROR 3 DETECTOR FAILED HY-5A vehicle detector -
Communication failed. The Smart
DC Controller will behave as if the detector is triggered, usually holding the gate fully open.
The alert indicates the detector is not communicating properly with the Smart
DC Controller. The alert occurs if the detector is unplugged or the detector has failed. To replace the detector, press the
RESET button to clear the error and re-seat the detector or install a new one.
Revision D Reference 6-23
Smart DC Controller Troubleshooting
Even if the loop problem self heals, historical data about detector/loop performance and a log of Alerts, Faults and Errors can be retrieved from the Smart DC Controller by downloading from the RS232 communications port or the USB port. HySecurity's free START software, a laptop computer, and a special download cable or
USB cable are required to retrieve and read this data.
Frequency:
Knowing the exact frequency of a loop can be useful as a diagnostic tool, and verifying the stability of the loop frequency is valuable information. To view the actual loop frequency of a specific vehicle detector, go to the setting for that detector in the Installer Menu, switch the selection from 0 to 1, and press the Select button.
The display will show the loop frequency. The frequency is usually between 20,000 to 80,000 Hertz.
Changing the Loop Frequency:
HY-5A detectors can never crosstalk. If for any reason, you want to manually change the loop frequency, change the Installer Menu option for the desired loop from 0 to 3, and then press the Select button. Each detector has a choice of four frequencies. Press the Select button when the desired frequency setting is found, and the controller will perform a reset and tune to the new frequency setting.
Call Strength Level:
Knowing the call strength of a detector is valuable because it provides information about how well the loop is actually “seeing” a specific vehicle. For example, it may be useful to check to see if the loop is easily detecting the middle of a high bed semi-truck. The strength of a detector call can be displayed in real time, on a scale of
0 to 7. As indicated in the table below, when the Installer Menu setting for a given detector is set to 2, and the
Menu button is pressed, the LCD display will read Level 0 - 7 Call Level. If the call strength on the display appears as a level 4 or less, consider increasing the sensitivity level by adjusting the rotary switch on the HY-5A detector.
Table 6-3 HY-5A Vehicle Detector Call Level Display
Installer
Menu
ELD 0
ILD 0
OLD 0
CLD 0
LCD Description
Setting Options
Bold = Factory Settings
EXIT LOOP SET
IN OBS LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
OUT OBS LOOP SET 0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
CENTER LOOP SET
(Can be used as an arming loop with User
Relay 22.)
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
6-24 SlideSmart DC Installation and Reference Manual Revision D
Smart DC Controller Troubleshooting
SlideSmart Schematics
Figure 6-14 illustrate the schematics for SlideSmart DC 15 and SlideSmart DC 10F.
Figure 6-15 shows the solar version.
Revision D
Figure 6-14.
Reference 6-25
Smart DC Controller Troubleshooting
6-26
Figure 6-15.
SlideSmart DC Installation and Reference Manual Revision D
General Maintenance
G
ENERAL
M
AINTENANCE
Smart Touch Analyze and Retrieve Tool
HySecurity provides Smart Touch Analyze and Retrieve Tool (START) software to help HySecurity gate operator users and installers conduct the following field service activities:
• Configure installer and user menu settings
• View the operator history (event) log
• Display monitored inputs for operator diagnostics
• Load Smart DC Controller (SDC) operator code
With START software loaded on your laptop computer, you have an invaluable management tool for all HySecurity operators. Either the USB port or the RS-232 serial port, found on the Smart DC Controller (see
Figure 6-16), allows you to download system diagnostics and upload
system configurations using the START software. The free START software is conveniently located on the www.hysecurity.com
website.
Instructions for downloading START are found on the website, as well.
RS-232
Connect to RS-232 with
If using a USB cable, connect it to the USB port.
W
HAT
Y
OU
N
EED
DC
PEN COM
OPTIONS
B COM
A
DUAL GATE
COM NO
• Standard USB 2.0 A-B communications cable. If you are using the
HySecurity RS-232 to USB adapter, be sure to install the USB driver in your laptop.
USB PORT RS-485
COMMUNICATION
Figure 6-16.
• Laptop computer with Windows PC operating system (XP, Vista, or
Windows 7)
• Minimum 128MB of RAM
• Minimum 5MB of hard drive disk space
• VGA graphics card (minimum resolution of 800 x 600)
I
NSTALLING
START S
OFTWARE
Read the START User Manual, and then take the following steps to download START software:
1. Bring up your web browser and type in http://www.hysecurity.com
in the command line.
2. Click Technical Support (left column) on the HySecurity home page.
3. Enter your user name and password. If you do not have a user name, register as an online member.
4. Click to Download: S.T.A.R.T. software for Smart Touch and Smart DC .
5. Read the End User License Agreement and, if you agree to the terms, click on, I accept (bottom of the page).
6. Click RUN . A setup window appears.
Revision D Reference 6-27
General Maintenance
Installing START Software, continued
NOTE
If the operating system on your laptop is VISTA or Windows 7, you must first disable the “User
Account Control Settings.” refer to the procedure in
Setting User Account Controls , and then con-
tinue with step 9.
7. Follow the step-by-step instructions to complete the installation.
8. When the download is complete, log out of the HySecurity website. Shortcuts for the START and Smart
DC Controller History Logs appear on your laptop’s desktop.
S
ETTING
U
SER
A
CCOUNT
C
ONTROLS
Because of the security settings inherent in VISTA and Windows 7, you need to disable the “user account controls” in the operating system before uploading START software onto your laptop. Take the following steps:
In Windows 7:
Go to Start Menu -> Control Panel -> User Accounts and Family Safety -> User Account -> Change User Account
Control Settings “slide the slide bar to the lowest value (toward Never Notify), with description showing Never notify me -> Press Ok -> Reboot Computer.
In Vista:
Go to the Start Menu type “msconfig” and press Enter -> In System Configuration select the tools tab -> Scroll down till you find "Disable UAC" and single click it -> Press the Launch button -> Press the Apply button -> Press
OK -> Reboot Computer.
Electrical Controls
!
CAUTION
Before servicing, turn OFF all power switches.
No routine maintenance is needed for the electrical system or controls. If the environment is very sandy or dusty, or has many insects, be certain to seal all holes in the electrical enclosure. Blow the dust out of the electric panel with compressed air. Use
Table 6-1 "Smart DC Controller - Troubleshooting" on page 6-17
to assess and fix error, alert, and fault codes. If it is necessary to call a distributor for assistance, be sure to have your model and serial number ready. Other helpful information includes the name of the job, approximate date of installation, and the service record of the operator.
6-28 SlideSmart DC Installation and Reference Manual Revision D
General Maintenance
Mechanical Maintenance
!
CAUTION
Before checking the internal mechanisms of the operator, turn off all power switches.
The SlideSmart mechanical maintenance is not in depth or difficult, but should be performed on a routine basis. The operator chassis is zinc plated, but some environments may speed corrosion of this plating.
Schedule regular maintenance and look for the following:
• Verify the drive belt has the proper tension. Check for drive belt wear. Fraying edges or missing teeth
indicate that the drive belt needs to be replaced. Refer to Drive Belt Tension and Alignment
.
• Check for signs of rust. If any areas of rust are found, reduce the spread of corrosion by treating the areas with a rust inhibitor.
• Check the motor. DC motors contain carbon brushes which wear over time and must be replaced. Failure to replace the brushes will result in damage to the DC motor. Brushes should be inspected every year in high usage applications or every 100,000 cycles and replaced as needed.
• Replace worn-out batteries. Refer to
and
Software Maintenance
The software on the SDC board is constantly being enhanced with new features that create an easier install and improve the on board diagnostic tools. Be sure to check the HySecurity website for the latest version of software before heading out for field maintenance.
Use S.T.A.R.T. software to download the latest software version to a PC laptop and upload it to the SlideSmart gate operator in the field.
NOTE
If the site includes a bi-parting gate system, make sure the software version used in the Master and Slave operators is identical.
Revision D Reference 6-29
General Maintenance
D
RIVE
B
ELT
T
ENSION AND
A
LIGNMENT
Slide the motor bracket.
1/16" to 1/8"
To adjust the tension or replace the belt, loosen 4 nuts and slide the motor bracket.
Retighten the fasteners when the adjustments are complete.
Figure 6-17.
Proper drive belt tension is important for prolonging the life of the drive belt and maintaining the superior performance of the operator. To check the drive belt tension, take the following steps:
1. Remove the SlideSmart cover and protection plate.
2. Turn off the AC and DC power switch.
3. Check to make sure the pulley is aligned horizontally.
4. With your finger, apply light outward pressure to the drive belt. If it is properly tensioned, it should only
move about 1/16 to 1/8-inch (1.6 to 3.2cm). See Figure 6-17.
5. To replace or re-tension the drive belt. Loosen the four motor bracket nuts and move the motor accordingly.
6. Retighten the motor bracket nuts.
7. Replace the protection plate and SlideSmart cover.
8. Turn the AC and DC power switches ON. This cycles power which allows the operator to search for the target magnet and “relearn” its limits.
9. If you don’t cycle the power, the operator will not “relearn” its limits to operate properly.
NOTE
Be aware that the gate will cycle open and close (close or open) as it relearns its limits.
See
Resetting the OPEN and CLOSE Limits .
6-30 SlideSmart DC Installation and Reference Manual Revision D
General Maintenance
DC B
ATTERY
R
EPLACEMENT
HySecurity provides a one year warranty from the date of shipment for all batteries supplied with the
SlideSmart operator.
Indicators of a low battery include:
• LOW BATTERY or DEAD BATTERY appears on the Smart DC Controller display which may or may not be indicative of normal discharge.
• ALERT 18 CHANGE BATTERY appears on the Smart DC Controller display. The operator emits an audible chirp every minute to indicate a problem exists.
• AP (#) AC LOSS appears on the Smart DC Controller display. Gate operation is affected by AC power loss depending on customer preferences and the configuration set by the installer in the AP (#) AC LOSS User
Menu.
NOTE
For detailed information about the AP AC LOSS configuration, refer to
.
Symptoms of a low battery may include:
• Gate remains locked in the open position
• Gate remains locked in the closed position
• Gate opens five seconds after AC power loss and locks open
!
CAUTION
Before replacing the batteries, turn off all power switches. Use only AGM batteries as replacements (8Ah - MX002008, 50Ah - MX002013). The batteries supplied in the SlideSmart operator are state-of-the-art AGM batteries. Do NOT use flooded cell batteries as damage may occur to the unit. Wear protective clothing while working with batteries.
The two 8Ah batteries are accessible within the operator on a tray behind the control box.
To replace the batteries, take the following steps:
1. Take off the SlideSmart cover and turn off the DC and
AC power switches.
2. To access the 8Ah batteries and disconnect its wires, cut the two black wire ties and slide the 8Ah batteries
through the access window. See Figure 6-18. Another
option is to remove the four screws that hold the control
box to the chassis. Refer to Figure 2-9.
3. Disconnect the black, blue, and red wires as you slide the batteries through the access window.
Cut away view of chassis
Disconnect wires
Access window
Figure 6-18.
Revision D Reference 6-31
General Maintenance
To install the two new batteries, reverse the removal procedure.
1. Connect the red wire to the red terminal on the left battery and slide the battery onto the tray.
2. Attach the blue wire to the black terminal.
3. Insert the second 8Ah battery and connect the blue wire to the red terminal).
4. As you slide the battery onto the tray, connect the black wire to the black terminal on the right battery.
Red wire
Black wire
Wire ties
Blue wires
Right battery
8Ah batteries
Figure 6-19.
NOTES
If you have difficulty removing the batteries through the access hole, an optional method for battery replacement is to remove the control box. Four Phillips-head screws secure the control box to the chassis. Remove the screws and remove the control box to access the batteries. Be careful that you do not inadvertently disconnect the control box wire bundles. An assistant for this alternative method of battery removal/replacement is highly recommended. See
Four Phillips-head screws secure the control box to the chassis.
Slide cover off the control box to access the screws.
Control box
Cut wire ties
8Ah battery
Figure 6-20.
Battery access window
6-32 SlideSmart DC Installation and Reference Manual Revision D
General Maintenance
C
LOCK
B
ATTERY
R
EPLACEMENT
A lithium coin battery supports the clock so the date and time is
retained even when the main power is turned off. See Figure 6-21.
Replace the battery about every five years (or as needed) with a DL
2025, DL 2032, or CR 2025, or CR 2032 battery.
USER 1
Lithium baery
DC
B COM
A
DUAL GATE
COM NO
Figure 6-21.
Revision D Reference 6-33
General Maintenance
This page intentionally blank.
6-34 SlideSmart DC Installation and Reference Manual Revision D
Installation Configurations
Appendix A
This appendix contains drawings of the various installation configurations for the SlideSmart operator.
Provided in this appendix are drawing specifications for:
• Concrete pad layout and dimensions
• Conduit and ground
• Base extension
• Post mounted
• Post mounted with base extension
• Rear mounted installation
Revision D Installation Configurations A-1
LTR DESCRIPTION
D ADDED SHEET 9 - POST MOUNTED IDLERS LOWERED.
GENERAL MOUNTING DIMENSIONS
Gate
3.25
2.50
Chain to Gate
5.50
2.66
10.50
1.63
6.75 x12
Conduit
Area
DATE
2/7/2012
APPRV'D
RAW
Chain, #40 Roller
21
Min Pad Size
4.31
10.38
19.0
Min Pad Size
Provisions for qty 4
1/2-13 X 3 1/2
Concrete Anchors
(1/2 inch slot in either direction)
Chain
Ground level
7.75
Chain Height
Pad 2" above ground.
Conduits stubbed minimum 2" above pad to a maximum of 4"
A-2
Hy
Security
Kent, Washington
NOTE: DRAWING IS NOT TO SCALE.
DOCUMENT TITLE
SLIDESMART INSTALLATION
SPECIFICATION
DRAWN
JEF
CHECKED
DATE
DATE
APPROVED
JEF
DATE
DOCUMENT NUMBER:
D0335
THIRD ANGLE PROJECTION
REV
D
SHT OF
1 9
SlideSmart DC Installation and Reference Manual Revision D
LTR DESCRIPTION
D ADDED SHEET 9 - POST MOUNTED IDLERS LOWERED.
OPERATOR SIZE, CONDUIT AND GROUNDING INFORMATION
Gate
3.25
2.50
Chain to Gate
Chain
DATE
2/7/2012
APPRV'D
RAW
18.0
20.0
Operator
Length
Route 6 AWG ground wire through conduit & attach to ground lug provided.
17.7
Operator
Width
Earth Ground
High Voltage
Consult local codes for proper depth
20.7
Operator
Height
Master/Slave Wires
(Optional)
Vehicle Loop
Control Wires
Low Voltage /
Communication Wires
3 Foot
Maximum
Hy Security
Kent, Washington
NOTE: DRAWING IS NOT TO SCALE.
DOCUMENT TITLE
SLIDESMART INSTALLATION
SPECIFICATION
DRAWN
JEF
CHECKED
DATE
DATE
APPROVED
JEF
DATE
DOCUMENT NUMBER:
D0335
THIRD ANGLE PROJECTION
REV
D
SHT OF
2 9
Revision D Installation Configurations A-3
LTR DESCRIPTION
D ADDED SHEET 9 - POST MOUNTED IDLERS LOWERED.
3.25
2.50
Chain to Gate
SLIDESMART DC: BASE RISER MOUNTED
Gate
Chain
5.50
2.66
12.5
If no batteries In Base Riser -
Conduit Area is 8.5"x12"
10.50
17.5
6x8.5
Conduit
Area
DATE
2/7/2012
APPRV'D
RAW
4X 1/2" x 3 1/2"
Concrete Anchors
10.38
18.0
3.25
2.50
CHAIN TO GATE
Optional 50Ah
Batteries
7.75
12.5
20.3
.72
*Note - reduced space when optional batteries are used.
Stub Conduits 2" above
Pad.
A-4
Hy Security
Kent, Washington
NOTE: DRAWING IS NOT TO SCALE.
DOCUMENT TITLE
SLIDESMART INSTALLATION
SPECIFICATION
DRAWN
JEF
CHECKED
DATE
DATE
APPROVED
JEF
DATE
SlideSmart DC Installation and Reference Manual
DOCUMENT NUMBER:
D0335
THIRD ANGLE PROJECTION
REV
D
SHT OF
3 9
Revision D
LTR DESCRIPTION
D ADDED SHEET 9 - POST MOUNTED IDLERS LOWERED.
SLIDESMART DC: POST MOUNTED
3.25
2.50
Chain to Gate
Gate Chain
10.50
2.66
5.00
4.00
3.81
6.75 x 9
Conduit
Area
5.50
10.38
18.0
DATE
2/7/2012
APPRV'D
RAW
17.5
4X .625
U-bolts provided for 4" OD pipe (slot allows for
3.5-4.5" OD pipe. For best results,
HySecurity recommends welding plate to posts.
3.25
2.50
Chain to Gate
20.7
3.0
7.75
Chain Height
Post
Height
6.0
.72
17.63 ID of
Post Mount Plate
Hy
Security
Kent, Washington
NOTE: DRAWING IS NOT TO SCALE.
DOCUMENT TITLE
SLIDESMART INSTALLATION
SPECIFICATION
DRAWN
JEF
CHECKED
DATE
DATE
APPROVED
JEF
DATE
Revision D Installation Configurations
DOCUMENT NUMBER:
D0335
THIRD ANGLE PROJECTION
REV
D
SHT OF
4 9
A-5
LTR DESCRIPTION
D ADDED SHEET 9 - POST MOUNTED IDLERS LOWERED.
3.25
2.50
Chain to Gate
SLIDESMART DC: POST MOUNTED WITH BASE RISER
2.66
10.50
5.00
4.00
3.81
4.5 x 7
Conduit
Area
5.50
10.38
18.0
DATE
2/7/2012
APPRV'D
RAW
If no batteries In Base Riser -
Conduit Area is 7"x9"
17.5
4X .625
U-bolts provided for 4" OD pipe (slot allows for
3.5-4.5" OD pipe). For best results,
HySecurity recommends welding plate to posts.
3.25
2.50
Chain to Gate
20.7
7.75
12.5
3.0
Post
Height
6.0
.72
A-6
Hy
Security
Kent, Washington
17.63 ID of
Post Mount Plate
NOTE: DRAWING IS NOT TO SCALE.
DOCUMENT TITLE
SLIDESMART INSTALLATION
SPECIFICATION
DRAWN
JEF
CHECKED
DATE
DATE
APPROVED
JEF
DATE
DOCUMENT NUMBER:
D0335
THIRD ANGLE PROJECTION
SlideSmart DC Installation and Reference Manual
REV
D
SHT OF
5 9
Revision D
LTR DESCRIPTION
D ADDED SHEET 9 - POST MOUNTED IDLERS LOWERED.
SLIDESMART DC: REAR MOUNTED INSTALLATION
DATE
2/7/2012
APPRV'D
RAW
4.75
8.0
7.75
3.25
Hy
Security
Kent, Washington
NOTE: DRAWING IS NOT TO SCALE.
DOCUMENT TITLE
SLIDESMART INSTALLATION
SPECIFICATION
DRAWN
JEF
CHECKED
DATE
DATE
APPROVED
JEF
DATE
Revision D Installation Configurations
DOCUMENT NUMBER:
D0335
THIRD ANGLE PROJECTION
REV
D
SHT OF
6 9
A-7
LTR DESCRIPTION
D ADDED SHEET 9 - POST MOUNTED IDLERS LOWERED.
SLIDESMART DC: REAR MOUNTED INSTALLATION
DATE
2/7/2012
APPRV'D
RAW
4.75
8.0
7.75
3.25
A-8
Hy
Security
Kent, Washington
NOTE: DRAWING IS NOT TO SCALE.
DOCUMENT TITLE
SLIDESMART INSTALLATION
SPECIFICATION
DRAWN
JEF
CHECKED
DATE
DATE
APPROVED
JEF
DATE
DOCUMENT NUMBER:
D0335
THIRD ANGLE PROJECTION
SlideSmart DC Installation and Reference Manual
REV
D
SHT OF
6 9
Revision D
LTR DESCRIPTION
D ADDED SHEET 9 - POST MOUNTED IDLERS LOWERED.
PLAN AND ELEVATION VIEWS - OPERATOR ONLY
DATE
2/7/2012
APPRV'D
RAW
SlideSmart Operator Only - Cover On
Hy
Security
Kent, Washington
SlideSmart Operator Only - Cover Removed
NOTE: DRAWING IS NOT TO SCALE.
DOCUMENT TITLE
SLIDESMART INSTALLATION
SPECIFICATION
DRAWN
JEF
CHECKED
DATE
DATE
APPROVED
JEF
DATE
DOCUMENT NUMBER:
D0335
THIRD ANGLE PROJECTION
REV
D
SHT OF
7 9
Revision D Installation Configurations A-9
LTR DESCRIPTION
D ADDED SHEET 9 - POST MOUNTED IDLERS LOWERED.
PLAN AND ELEVATION VIEWS - OPERATOR ON BASE RISER
DATE
2/7/2012
APPRV'D
RAW
SlideSmart Operator On Optional Base Riser - Cover On
SlideSmart Operator On Optional Base Riser - Cover Removed
NOTE: DRAWING IS NOT TO SCALE.
Hy
Security
Kent, Washington
DOCUMENT TITLE
SLIDESMART INSTALLATION
SPECIFICATION
DRAWN
JEF
CHECKED
DATE
DATE
APPROVED
JEF
DATE
DOCUMENT NUMBER:
D0335
THIRD ANGLE PROJECTION
REV
D
SHT OF
8 9
A-10 SlideSmart DC Installation and Reference Manual Revision D
LTR DESCRIPTION
D ADDED SHEET 9 - POST MOUNTED IDLERS LOWERED.
ELEVATION VIEWS - OPERATOR POST MOUNTED, IDLERS LOWERED
DATE
2/7/2012
APPRV'D
RAW
SlideSmart Operator On Optional Post Mount - Cover On
SlideSmart Operator On Optional Post Mount - Cover Removed
NOTE: DRAWING IS NOT TO SCALE.
Hy
Security
Kent, Washington
DOCUMENT TITLE
SLIDESMART INSTALLATION
SPECIFICATION
DRAWN
JEF
CHECKED
DATE
DATE
APPROVED
JEF
DATE
DOCUMENT NUMBER:
D0335
THIRD ANGLE PROJECTION
REV
D
SHT OF
9 9
Revision D Installation Configurations A-11
A-12 SlideSmart DC Installation and Reference Manual Revision D
Parts & Limited Warranty
S
LIDE
S
MART
P
ARTS IN
P
RICE BOOK
Board, Smart DC Controller
Control Box
Buzzer
Reset Switch, Internal
Switch, On/Off
Circuit Breaker
Switch, On/Off
Detector, Vehicle
Board, Power Supply
Solar Control Box
Pulley, Motor
Motor, Electric
Brush Kit
Battery Kit, 8 Ah
Cover, 2-Piece
Belt, Drive
Pulley, Gearbox
Gearbox
Transformer
Sprocket
Target, Sensor Switch
Cover, 2-Piece
Target, Magnet
Chain
Idler Wheel
Battery Kit, 50 Ah
Base Extension
Revision D G-1
S
LIDE
S
MART
P
ARTS
L
IST
Part Name
Base Extension
Battery Kit, 50AH, Replacement
Battery Kit, 8AH, Replacement
Belt, Drive, SlideSmart DC 10F
Belt, Drive, SlideSmart DC 15
Board, Power Supply, 115/230VAC
Board, Smart DC Controller
Brush Kit, 24VDC Motor
Buzzer, Piezo
Chain Kit #40, 30 foot (9 m)
Circuit Breaker, 15 Amp
Circuit Breaker, 3 Amp
Cover, 2-Piece, SlideSmart
Detector, Vehicle, HY-5A
Gearbox, SlideSmart
Idler Wheel, #40 Roller Chain Guide
Motor, Electric, 24VDC, SlideSmart
Pulley, Gearbox, 36T
Pulley, Gearbox, 60T
Pulley, Motor
Reset Switch, Internal
Sprocket, #40 Roller Chain
Switch, On/Off
Target, Magnet, SlideSmart
Target, Sensor Switch, SlideSmart
Transformer, 115/230VAC
Part Number SlideSmart Models
MX002094
MX002013
MX002008
MX002107
MX002106
MX001766
MX001457
MX001920
MX001036 all all all
SlideSmart 10F
SlideSmart 15
AC only all all all
MX002113 all
MX001760
MX001762
MX002115
MX000041
MX002210
MX002181
MX001995
MX001404
MX002076
MX001403
MX002124
MX002211
MX001761
MX002087
MX002085
MX001682
Solar only
AC only all all all all all
SlideSmart 10F
SlideSmart 15 all all all all all all
AC only
Note: See HySecurity Price Book for replacement parts and kits.
G-2 Revision D
6623 South 228th St.
Kent, WA 98032-1872
800-321-9947
LIMITED WARRANTY
1. Warranty.
Hy-Security Gate, Inc. (“HySecurity”) warrants that at the time of sale each of its products will, in all material respects, conform to its then applicable specification and will be free from defects in material and manufacture. This warranty does not extend to items listed as “accessories” in HySecurity’s price list, when those items carry another manufacturer’s name plate and they are not a part of the base model. HySecurity disclaims all warranties for such accessory components, which carry only the original warranty, if any, of their original manufacturer. HySecurity hereby assigns its rights under such manufacturer warranties—to the extent that such rights are assignable—to
Buyer. The following additional durational warranties apply to HySecurity’s products.
The term of these additional warranties is determined by whether (1) the product is purchased through an authorized HySecurity distributor and (2) whether a timely and complete warranty registration is submitted to HySecurity. It is therefore important that you register your product with HySecurity within the 60 day period described below.
1(a) Warranty Items (Registered Gate Operators Purchased from Authorized Distributors)
For any gate operator product that is purchased from an authorized HySecurity distributor (this excludes product purchased through internet resellers or any distributor not authorized by HySecurity), if the online Warranty registration is completed at www.hysecurity.com/warranty within 60 days of the date of purchase by the dealer/installer and returned to HySecurity within the same 60-day period, the following Warranty terms will apply. HySecurity will warrant that the product will remain serviceable for the following periods: a. Hydraulic Gate Operators: Five Years or 500,000 gate cycles (whichever occurs first) after the date of installation, or b.
Electromechanical Barrier Arm Operators: Two Years or 1,000,000 gate cycles
(whichever occurs first) after the date of installation, or c.
Electromechanical Slide and Swing operators: Five Years after the date of installation—unless installed in a single family residential application, in which case the warranty term shall be Seven Years after the date the product is shipped from HySecurity; provided that the Five Year warranty period will not extend beyond Seven Years from the date that the product was shipped from
HySecurity. This warranty does not apply to the components described below, which have the shorter warranty period indicated: d.
Hydraulic Gate Operator Drive Wheels including XtremeDrive™ wheels and rack:
Two Years from date of installation.
e.
Batteries used in all D.C. operators, inverters or other battery powered devices:
One Year from date of shipment from HySecurity.
f. Items subject to normal wear including, but not limited to, chains, belts, idler wheels, sprockets, fuses and motor brushes: One Year from date of installation.
1(b) Warranty Items (Operators Not Purchased from an
Authorized Distributor or Registered within 60 Days)
For any gate operator product that is not purchased from an authorized HySecurity distributor or for which the online Warranty registration or warranty registration form sent with every HySecurity operator was not filled out completely or not returned to
HySecurity within 60 days of the date of purchase by the dealer/installer, the following
One-Year Warranty will apply to that product: HySecurity warrants that the product will remain serviceable for the following periods, which begin on the date that the product was shipped from HySecurity: a.
All Gate Operators: One Year or 100,000 gate cycles whichever comes first.
b.
Hydraulic Gate Operator Drive Wheels: One Year
1(c) Replacement Parts
HySecurity warrants that replacement parts (whether new or reconditioned) will remain serviceable for One Year from the date that the product was shipped from HySecurity.
1(d) Limitations and Exclusions Applicable to Each of the
Preceding Warranties
The preceding warranties shall not apply to equipment that has been (1) installed or maintained improperly or contrary to instructions; (2) subjected to negligence, accident, vandalism, or damaged by severe weather, wind, flood, fire, or war; or www.hysecurity.com © 2014 800-321-9947
(3) damaged through improper operation, maintenance, storage or abnormal or extraordinary use or abuse. Any modification made to products will void the warranty unless the modifications are approved in writing by HySecurity, in advance of the change (this exclusion does not apply to normal installation of approved accessories and/or protective devices or sensors). It is the responsibility of the distributor, installer, or End User to ensure the software version in the operator is maintained to the latest revision level.
THESE ARE THE ONLY WARRANTIES GIVEN BY HYSECURITY
AND ARE IN PLACE OF ALL OTHERS.
These warranties extend to HySecurity’s Distributors, to the Dealer/Installer, and to the End User of the product following installation. They do not extend to subsequent purchasers. Dealer/Installers or End Users may receive a replacement HySecurity
Warranty form by calling HySecurity at 800-321-9947.
2. Exclusion of Other Warranties.
The warranties contained in Section 1 are the exclusive warranties given by HySecurity and supersede any prior, contrary or additional representations, whether oral or written. Any prior or extrinsic representations or agreements are discharged or nullified.
HYSECURITY HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES—
WHETHER EXPRESS, IMPLIED, OR STATUTORY—INCLUDING ANY WARRANTY
OF MERCHANTABILITY, ANY WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE, AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM
COURSE OF DEALING, COURSE OF PERFORMANCE, OR USAGE OF TRADE.
3. Buyer’s Exclusive Remedies for Any Nonconformity.
If a HySecurity product fails to conform to the warranties in Section 1, Buyer must notify and order replacement parts from the Distributor through which the product was purchased within a reasonable time and in no event more than thirty (30) days after the discovery of the nonconformity. HySecurity will investigate and, in the event of a breach, will provide, within a reasonable period of time, one of the following: (1) repair or replacement of any nonconforming products or components or (2) refund of the price upon return of the nonconforming items. Replacement goods will conform to this warranty for the unexpired duration of the warranty period for the original, nonconforming product. HySecurity reserves the right to supply used or reconditioned material for all warranty claims. This warranty does not cover or extend to any incidental expenses, including labor, shipping, travel time or standby time, that are incurred for inspection or replacement of any nonconforming items. As a condition of warranty coverage, warranty claims must be submitted in accordance with the following paragraph.
THE REMEDY SELECTED BY HYSECURITY IN ACCORDANCE WITH THIS
PARAGRAPH SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER
FOR ANY BREACH OF WARRANTY. IN NO EVENT SHALL HYSECURITY BE
OBLIGATED TO INDEMNIFY BUYER FOR ANY BREACH OF WARRANTY.
For warranty coverage, you must follow the procedures described on HySecurity’s form,
“RMA Procedures.” A current version of the form is available from HySecurity.
4. Exclusion of Consequential and Incidental Damages.
IN NO EVENT SHALL HYSECURITY BE LIABLE FOR ANY INCIDENTAL, SPECIAL,
INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM
NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE
PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM HYSECURITY’S
OWN NEGLIGENCE OR OTHER TORT.
This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, or strict liability in tort or under any other legal theory. This exclusion does not apply to claims for bodily injury or death.
5. Severability.
If any provision of this warranty is found to be invalid or unenforceable, then the remainder shall have full force and effect, and the invalid provision shall be partially enforced to the maximum extent permitted by law to effectuate the purpose of the agreement.
6. Applicable Law.
This Warranty will be interpreted, construed, and enforced in all respects in accordance with the laws of the State of Washington, without reference to its choice of law principles. The U.N. Convention on Contracts for the International Sale of Goods will not apply to this Warranty.
Limited Warranty
S
LIDE
S
MART
DC S
PECIFICATIONS
Model
Max. Gate Length
Max. Gate Weight
Gate Speed
UPS Operation on
Batteries only
Duty Cycle
Power: Single phase
(switch selectable)
Horsepower
Accessory Power
Two Programmable
User Relays
Communication
Temperature Rating
Certification
DC Batteries
Est. Shipping Weight
UL Listing
Limited Warranty
SlideSmart DC 15 SlideSmart DC 10F SlideSmart Solar
40 ft (12.2m)
1,500lbs (680kg)
40 ft (12.2m)
1000lbs (45 3 kg)
40 ft (12.2m)
DCS 15 = 1,500lbs (680kg)
DCS 10F = 1,000lbs (454kg)
1ft/s , 1.25 for Usage Class III & IV 2ft/s , 2.25 for Usage Class III & IV 1ft/s and 2ft/s, respectively
Up to 4,000ft of gate travel
(1,219m)
Up to 4,000ft of gate travel
(1,219m)
Up to 1,500ft (457m) of gate travel per day (8Ah batteries fullycharged)
Continuous
115 volts, 3 amps, 50/60 Hertz
230 volts, 1.5 amps, 50/60 Hertz
Continuous
115 volts, 3 amps, 50/60 Hertz
230 volts, 1.5 amps, 50/60 Hertz
Continuous
Solar-powered (24VDC, two
20 WATT panels) 70 cycles/day in a full sun for 3 hours
½ hp
1 amp each at 12VDC, 24VDC, and 24VAC
250VAC, 10A
30VDC, 3A
USB, RS232, RS485
-13°F to 158°F (-25°C to 70°C)
500,000 cycles
Two 8Ah (50Ah - optional)
160 lbs. (73 kg)
Class I, II, III, IV
5 years commercial use (7 years for single-family residence)
½ hp
1 amp each at 12VDC, 24VDC, and 24VAC
250VAC, 10A
30VDC, 3A
USB, RS232, RS485
-13°F to 158°F (-25°C to 70°C)
500,000 cycles
Two 8Ah (50Ah - optional)
160 lbs. (73 kg)
Class III, IV
5 years commercial use
½ hp
1 amp each at 12VDC and
24VDC
250VAC, 10A
30VDC, 3A
USB, RS232, RS485
-13°F to 158°F (-25°C to 70°C)
500,000 cycles
Two 8Ah (50Ah - optional)
150 lbs. (68)
DCS 15 = Class I, II, III, IV
DCS 10F = Class III, IV
5 years commercial use (7 years for single-family residence)
Copyright Notice
© Copyright 2012 by HySecurity Gate Inc.
All rights reserved. No part of this manual may be reproduced by any means (photocopier, electronic, or mechanical), without the express written permission of HySecurity Gate Inc. Federal Copyright law prohibits the reproduction, distribution, or public display of copyrighted materials without the express written permission of the copyright owner, unless fair use or other exemption under copyright law applies.
Additionally, HySecurity Gate Inc. makes no representations or warranty with respect to this manual. We also reserve the right to make changes in the products described without notice and without any obligation to notify any persons of any such revision or change.
Trademarks
SlideSmart, Smart DC Controller, S.T.A.R.T. and the HySecurity logo are trademarks or registered trademarks of HySecurity Gate, Inc.
Publication Information
Published in the United States of America.
June 22, 2012 Document Number: D0337 Revision D