Yaskawa Drive Options Manual
PDF
Document
Advertisement
Advertisement
YASKAWA VARISPEED-616PC5/P5 OPTION CARD CURRENT MONITOR CARD CM-A2/P INSTRUCTIONS Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference. 7 YASKAWA MANUAL NO. TOE-C736-40.9 NOTES FOR SAFE OPERATION Read this instruction manual thoroughly before installation, operation, maintenance or inspection. In this manual, the NOTES FOR SAFE OPERATION is classified as "CAUTION”. /\ CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to personnel and damage to equipment. It may also be used to alert against unsafe practices. Even items described in |A CAUTION | may result in a vital accident in some situations. In either case, follow these important items. © : These are steps to be taken to insure proper operation and e to avoid malfunctions, etc. /\ CAUTION - The option card uses C MOS IC chips. It may break if touched by bare fingers because of static electricity. Be careful when handling. - When removing the option card from the inverter for transportation or stor- age, put the card into the anti-static package it was in when delivered. - Never change wiring or connect or disconnect connectors while the power is ON. Failure to observe this caution may injure you. Current monitor card, CM-A2/P is mounted on the control board of the invert- er to convert analog monitor signals (0 to 10V) of the inverter to current signals (4 to 20 mA). This option card is applicable to the following inverter series: VS-616PCS/PS: Entire series Name Code No. Functions Current Convert analog monitor signals (0 to 10V) to monitor card 73600-D010X current signals (4 to 20 mA). CM-A2/P Non-insulated type Spacer mounting hote (4.0mm dia. X 4) Connector to inverter control board (2СМ} 1 o CODE но. [7350000100] © uo, 2 Al 01 ci Ho Hn Lu WAL PAT 4-0 AM nera O 2 Y ¡a Y / TT Terminal block TC for 4 to Analog monitor signals (O to . tG¥) input lead wire 20mA current monitor output Connacted to AM terminal of invertar control board Grounding lead wire [connected lo terminal E (G) of inverter control board] ss a 8 u H= a = т He O Fig. 1 Current monitor card CM-A2/P © Before use, o (1) Before using CM-A2/P, read this manual and the manual for the installation of the inverter. (2) Before connecting CM-A2/P or external terminals, turn OFF main power of the inverter and verify the CHARGE indicaor lamp of the inverter 1s OFF. When ordering CM-A2/P, specify the name and code number. 1 Inspection after Delivery А CAUTION - Verify that ordered products have been delivered. Installation of a wrong device may lead to injury or damage. Though the products have undergone rigorous inspection before shipping, check the following for safety. » Check the name written on the product to verify that ordered products have been delivered. ® Check for damage caused during transportation. If there is anything uncertain on the structure, contact your YASKAWA represen- tative. 2 Installing to Inverter (See Fig. 2) 2.1 Installation Procedure (1) Turn OFF the main power and wait for the time specified on the cover of the inverter. Remove the cover and verify that the CHARGE indicator lamp is OFF. (2) Position current monitor card CM-A2/P on the control board of the inverter. Gently push CM-A2/P until the spacer engages the four spacer holes of the option card on the control board. Fix CM-A2/P tightly. (See part A of the side view.) (3) Plug the connector 2CN of CM-A2/P into 2CN of the control board of the inverter. (4) After installing CM-A2/P, connect the inverter with peripheral devices and replace the cover of the inverter. „Г | CMAZR,, | 2CN Option __| connector Control board — Grounding terminal — Connector terminal Front view Side view Fig.2 Installation of current monitor card CM-A2/P 3 Interconnection Fig. 3 shows interconnection between the inverter, CM-A2/P, and peripheral equipment. Inverter MCCB —_ Motor — 0 © L1(A) U(T1) —< à © L2(S) V(T2)0 Ln) wa À 9 L3(T) W(T3)o VS-616PCS/P5 Current monitor TC RES = AM A va |- Do: PT ur [} 250 0 T' ul. | 1 rr sr + E Current monitor card CM-A2/P Fig. 3 Interconnection diagram Notes on wiring - Separate the wires for current output signals ( from terminal block TC1) of the CM-A2/P from the main circuit wires and other power cables. - Use a shielded wire to connect for current output signals. Connect the wire as shown in Fig. 4 to prevent interference by noise. Shielded Sheath Armor 05% we Connect to terminal TC et of CM-A2/P Sd eet ni To grounding terminal of current monitor Never connect. Insulate these parts with insulating tape. Fig.4 Shielded wire termination 4 Wiring See Table 1 for the functions of the external terminals. Table 1 External terminals Terminal block Pin No. Functions symbol ] Current monıtor output (+) TC 2 Current monitor output (—) Make sure the followings when wiring. ® To prevent noise, use shielded wire in the specified area in Fig.3 and sepa- rate from heavy current circuits (200VAC or greater) or relay drive circuits. Wire length must be 50m or shorter. + Connect the grounding lead wire (E) to grounding terminal Е (С) of the con-. trol board of the inverter. + Applicable wire sizes for terminal block TC is shown below. [Terminal: MKDS1 series manufactured by Phoenix Contact GmbH & Co.] [mm] AWG | [A] VAC [V] Thin twisted wire 16 12 125 Solid wire 1.5 16 12 125 UL = 22-16 10 300 CSA — 28-16 10 300 CSA — 28-16 10 150 5,5 mm Terminal block TC side Connecting wire end Notes on selecting cables Too thick a cable applies pressure to the option card and may lead to failure. Too thin a cable may lead to imperfect contact or a break in the wire. eee CURRENT MONITOR CARD CM-A2/P INSTRUCTIONS TOKYO OFFICE New Pier Takeshiba South Tower, 1-16-1, Kaigan, Minatoku, Tokyo 105 Japan Phone (03)5402-4511 Fax (03)5402-4580 YASKAWA ELECTRIC AMERICA, INC. Chicago-Corporate Headquarters 2942 MacArthur Blvd. Northbrook, IL 60062-2026, U.S.A Phone (847)291-2340 Fax (847)498-2430 Chicago-Technical Center 3160 MacArthur Blvd. Northbrook, iL 60062-1917, U.S.A. Phone (847)291-0411 Fax (B47)291-1018 MOTOMAN INC. 805 Liberty Lane Wes! Carrolllon, ОН 45449, USA. Phone (513)847-6200 Fax (513)847-6277 YASKAWA ELETRICO DO BRASIL COMÉRCIO LTDA. Avenida Brigadeim Faria Lima 1664-5" CJ 504/511, Säo Paulo, Brazil Phone (011)815-7723 Fax (011)870-3349 YASKAWA ELECTHIC EUROPE GmbH Am Kronberger Hang 2, 65824 Schwalbach, Germany Phone (49)6196-569-300 Fax (49)6196-888-301 Motoman Hobotics AB Box 504 $38525 Torsäs, Sweden Phone 6486-10575 Fax 0486-41410 Motoman Robotec GmbH Kammerfeldstrafe 1, 85391 Allershausen, Germany Phone 08166-900 Fax 08166-9039 YASKAWA ELECTRIC UK LTD. 3 Drum Mains Park Orchardton Woods Cumbernaukd, Scotland, G68 9LD U.K. Phone (1236)735000 Fax (1236}458182 YASKAWA ELECTRIC KOREA CORPORATION Paik Nam Bldg. 901 188-3, 1-Ga Euljiro, Joong-Gu Seoul, Korea Phone (02776-7644 Fax (02)753-2639 YASKAWA ELECTRIC (SINGAPORE) PTE. LTD. 151 Lorong Chuan, #04-01, New Tech Park Singapore 556741, SINGAPORE Phone (65)282-3003 Fax (65)289-3003 YATEC ENGINEERING CORPORATION Shen Hsiang Tang Sung Chiang Building ЮР 146 Sung Chiang Road, Taipei, Taiwan Phone (02)563-0010 Fax (02)567-4677 BEIJING OFFICE Room No. 301 Office Building of Beijing Intemationat Club, 21 jianguomenwai Avenue, Beijing 100020, CHINA Phone (86)10-532-1850 Fax (85)10-532-1851 SHANGHAI OFFICE Room No.8B Wan Zhong Building 1303 Yan An Road (West), Shanghai 200050, CHINA Phone (86)6212-1015 Fax (86)6212-1326 YASKAWA JASON (HK) COMPANY LIMITED Am. 2916, Hong Kong Plaza, 186-191 Connaught Road West, Hong Kong Phone (852)2858-3220 Fax (852)2547-5773 TAJPE1 OFFICE Shen Hsiang Tang Sung Chiang Building 10F 146 Sung Chiang Road, Taipei, Taïwan Phone (02)563-0010 Fax (02)567-4677 YASKAWA ELECTRIC CORPORATION YASKAWA MANUAL NO. TOE-C736-40.9 © Printed in Japan August 1996 95-1203 <> ">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement