Yaskawa Network Comms-Modbus RTU Manual
PDF
Hati
Tangazo
Tangazo
YASKAWA
VARISPEED-616G5 OPTION CARD
RS-232C/485 INTERFACE CARD SI-K2
INSTRUCTIONS
Upon receipt of the product and prior to initial operation, read these
instructions thoroughly, and retain for future reference.
7
YASKAWA MANUAL NO. TOE-C736-40.6
NOTES FOR SAFE OPERATION
Read this instruction manual thoroughly before installation,
operation, maintenance or inspection. In this manual, the NOTES
FOR SAFE OPERATION is classified as “CAUTION”.
À CAUTION
Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury to personnel and damage to
equipment.
It may also be used to alert against unsafe practices.
Even items described in | AX CAUTION | may result in a vital accident in
some situations. In either case, follow these important items.
& : These are steps to be taken to insure proper operation and
e to avoid malfunctions, etc.
A CAUTION
. The option card uses C MOS IC chips. It may break if touched by bare
fingers because of static electricity. Be careful when handling.
. When removing the option card from the inverter for transportation or stor-
age, put the card into the anti-static package it was in when delivered.
. Never change wiring or connect or disconnect connectors while the power
is ON.
Failure to observe this caution may injure you.
RS-232C/485 interface card, SI-K2 is mounted on the control board of the
inverter to input/output various signals from external devices by the RS-485
serial interface.
This option card is applicable to the following inverter series:
VS-616G5: Entire series
Name Code No. Functions
RS-232C/485 Convert the level of RS-232C inverter standard
interface card 73600-C015X function and offer the RS-485 interface
SI-K2 Maximum transmission speed: 9600bps
Connector to inverter Spacer mounting hole
Externai Terminal control board (2CN) (4.0mm dia. X 2)
block TC1 N ] 4
CObE|NO.[(731800-C0150l,
Rte ot tas one Bi-K2k В wy” \
1 ||-- a UL
“ANP “LI ОЕ
LY. “Fy as’ [SH I
+ > ST ег
[e | | | TI ры о 4 sf fa
a HE 44
— er Im en
\ 1 —
Terminal TC2 1 ; | | ЕН | Фе = =
(for connecting o | 78 + | TL EN T Hs US
+
MADE IN JAPAN
shielded sheath) u“
I
CET чо О
Ен ai НН 4 ı
. | 5 $ om
Grounding lead wire 2 37 x & [
(connected to pin #12 rig +
of inverter control board)
Fig. 1 RS-232C/485 interface card SI-K2
Before use,
(1) Before using SI-K2, read this manual and the manual for the
installation of the inverter.
(2) Before connecting SI-K2 or external terminals, turn OFF main power
of the inverter and verify the CHARGE indicaor lamp of the inverter is
OFF.
(3) When ordering SI-K2, specify the name and code number.
1 Inspection after Delivery
A CAUTION
- Verify that ordered products have been delivered.
Installation of a wrong device may lead to injury or damage.
Though the products have undergone rigorous inspection before shipping, check
the following for safety.
+ Check the name written on the product to verify that ordered products have
been delivered.
+ Check for damage caused during transportation.
If there is anything uncertain on the structure, contact your YASKAWA represen-
tative.
2 Installing to Inverter (See Fig. 2)
2.1 Installation Procedure
(1) Turn OFF the main power and wait for the time specified on the cover of the
inverter. Remove the cover and verify that the CHARGE indicator lamp 1s
OFF.
(2) Plug the 2CN connector of RS-232C/485 interface card SI-K2 into the 2CN
connector (60 pins) on the control board of the inverter. Gently push SI-K2
until the spacer engages the rwo spacer holes of the option card on the con-
trol board. Fix SI-K2 tightly. (See part A of the side view.)
(3) Plug the 6CN cable of SI-K2 into 6CN of the inverter.
(4) After installing SI-K2, connect the inverter with peripheral devices and re-
place the cover of the inverter.
Spacer mounting
hole
re A т - ., Mounting base
¡e ati oP CE of inverter
i
4CN Option fo 0 A FCN ] т
Aconnectot |... ne
à O a
SI-K2
2CN Option ot ee TT
С connector “bs ee mu
oi ni a
E on о a Control board
3CN Option |:
B connector 3
Connector _
terminal
Grounding terminal @ Bottom Side view
Front view
Fig. 2 Installation of RS-232C/485 interface card SI-K2
3 Interconnection
Fig. 3 shows interconnection between the inverter, SI-K2, and peripheral equip-
ment.
Inverter
Three phase (В) U(T1)
power supply L2(S) V{T2)
L3(T) W(F3)
SI-K?
| VS-616G65
it С! | см (60P)
1
(+) 7 O N
RS-485 ‘ =
(> Wo 5 KH
SAMA 2CN (60P)
sRO] 4
gr OFF 4 kk =
La a т
Termination
resistor BON (4P)
102
SI-K2
A
ga
Y
|
Termination
resistor
Fig.3 Interconnection diagram
Notes on wiring
- Separate the wires for transmission ( from terminal TC1) of SI-K2 from the
main circuit wires and other power cables.
+ Use a shielded wire to connect for transmission. Connect the wire as shown
in Fig. 4 to prevent interference by noise.
Shielded Sheath Armor
ARA,
To TC2 (E) on the
Never connect.
SI-K2 side terminal
Insulate these parts
with insulating tape.
Fig.4 Shielded wire termination
4 Wiring
See Table | for the functions of the external terminals.
Table 1 External terminals
Terminal block | Pin
symbol No. Functions Remarks
| | S/R (+) RS-485 input/output (+) | Use as input at
2 | SRC) RS-485 input/output (-) | parallel connection
TC! =
3 | S/R (+) RS-485 input/output (+) Use as output at
parallel
TC2 Shielded sheath connection terminal —
Make sure the followings when wiring.
¢ To prevent noise, use shielded wire in the specified area in Fig.3 and sepa-
rate from heavy current circuits (200VAC or greater) or relay drive circuits.
* Connect the grounding lead wire (E) to pin (2) of the control board of the
inverter.
° Applicable wire sizes for terminal block TC1 is shown below.
(Terminal: MKDS 1 series manufactured by Phoenix Contact GmbH & Co.]
[mm] AWG | [A] VAC [V]
Thin twisted wire | 16 12 125
Solid wire 1.5 16 12 125
UL — 22-16 10 300
CSA — 28-16 10 300
CSA — 28-16 10 150
Terminal block TC 1 side
Connecting wire end
Notes on selecting cables
Too thick a cable applies pressure to the option card and may lead to failure.
Too thin a cable may lead to imperfect contact or a break in the wire.
5 SW1 ON-OFF
When SW! is ON, the termination resistor (100 42) in the SI-K2 is connected
between S/R{+) and S/R(-).
(1) For one-to-one connection of the RS-232C/485 interface card SI-K2 and
the instruction master equipment, set SW1 of the SI-K2 to ON.
Master equipment к?
85-485 |
ON
(2) If more than one SI-K2 is connected to the instruction master equipment, set
SW 1 of only the last SI-K2 to ON.
Master equipment
oe ee eee ee = ad er
a >
OL
2
If all the SI-K2s have their SW1s ON, drive capacity of RS-485 may become
insufficient to maintain proper communication.
[|
RS-232C/485 INTERFACE CARD SI-K2
INSTRUCTIONS
TOKYO OFFICE Chtemachi Bkig, 1-6-1 Ohtemachi, Chiyoda-ku, Tokyo, 100 Japan
Phone (03)3284-9111 Telex YASKAWA J33530 Fax (03)3284-9034
YASKAWA ELECTRIC AMERICA, INC.
Chicago-Corporata Headquarters 2942 MacArthur Blvd. Northbrook, IL 60062-2028, U.S.A
Phone (708)291-2340 Fax (708)499-2430
Chicago-Technical Center 3160 MacArthur Blvd. Northbrook, IL 60062-1917, U.5.A.
Phone (708)291-0411 Fax (708)291-1018
MOTOMAN INC.
805 Liberty Lane West Carrollton, OH 45449, U.S.A.
Phone (513)847-6200 Fax (513)847-6277
YASKAWA ELÉTRICO DO BRASIL COMÉRCIO LTDA.
Avenida Brigadeiro Faria Lima 1664-5" CJ 504/511, 530 Paulo, Brazil
Phone (011)825-7723 Fax (011)210-9781
YASKAWA ELECTRIC EUROPE GmbH
Am Kronberger Hang 2, 65824 Schwalbach, Germany
Phone (49)6196-569-300 Fax (49)6196-888-301
Motoman Robotics AB
Box 504 $38525 Torsds, Sweden
Phone 0486-10575 Fax 0486-41410
Motoman Robotec GmbH
Kammerteldstrage 1, 85391 Allershausen, Germany
Phone 08166-900 Fax 08166-9039
YASKAWA ELECTRIC UK LTD.
3 Drum Mains Park Orchardton Woods Cumbemauld, Scotland, G68 91.0 U.K.
Phone (1236)735000 Fax (1236)458182
YASKAWA ELECTRIC KOREA CORPORATION
Paik Nam Bidg. 901 188-3, 1-Ga Euljiro, Joong-Gu Seoul, Korea
Phone (02)776-7844 Fax (02)753-2639
YASKAWA ELECTRIC (SINGAPORE) PTE. LTD.
Head Office : CPF Bldg. 79 Robinson Road # 13-05, Singapore 068897, SINGAPORE
Phone 221-7530 Telex (87}24890 YASKAWA RS Fax 224-5854
Service Center : 221 Henderson Road, # 07-20 Henderson Building Singapore 159557, SINGAPORE
Phone 276-7407 Fax 276-7406
YATEC ENGINEERING CORPORATION
Shen Hsiang Tang Sung Chiang Building 10F 146 Sung Chiang Road, Taipei, Taiwan
Phone (02)563-0010 Fax (02)567-4677
SHANGHAI OFFICE Room No.88 Wan Zhong Building 1303 Yan An Road (West), Shanghai 200050, CHINA
Phone (86)212-1015 Fax (86)212-1015
TAIPEI OFFICE Shen Hsiang Tang Sung Chiang Building 10F 146 Sung Chiang Road, Taipei, Taiwan
Phone (02)563-0010 Fax (02)567-4677
YASKAWA ELECTRIC CORPORATION
YASKAWA
MANUAL NO. TOE-C736-40.6
© Printed in Japan December 1995 95-12 0.5
">
/