STMicroelectronics ST25TA02K-D Datasheet
Advertisement
Advertisement
ST25TA02K-D
NFC Forum Type 4 Tag IC with 2-Kbit EEPROM
and general purpose digital output
Datasheet
-
production data
UFDFPN8 UFDFPN5
Wafer
Features
Contactless interface
• NFC Forum Type 4 Tag, certified by the NFC
Forum
• ISO/IEC 14443 Type A
• 106 kbps data rate
• Internal tuning capacitance: 50 pF
Memory
• 256-byte (2-kbit) EEPROM
• Supports NDEF data structure
• Data retention: 200 years
• Endurance: 1 million erase-write cycles
• Reads up to 255 bytes in a single command
• Writes up to 54 bytes in a single command
• Chaining capability
• 7-byte unique identifier (UID)
• 128-bit password protection
• 20-bit event counter with anti-tearing
• RF field detect
Package
• UFDFPN8 ECOPACK ® 2
• UFDFPN5 ECOPACK ® 2
Digital pad
• GPO: configurable general purpose output driven by an open drain transistor.
Description
The ST25TA02K-D device is a dynamic
NFC/RFID tag IC with a general purpose digital output.
It embeds an EEPROM memory. It can be operated from a 13.56 MHz RFID reader or an
NFC phone.
The ST25TA02K-D is an NFC Forum Type 4 Tag; it communicates using the ISO/IEC 14443 Type A protocol.
October 2017
This is information on a product in full production.
DocID027817 Rev 5 1/66 www.st.com
Contents
Contents
ST25TA02K-D
SS
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
General Purpose Output (GPO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Session Open configuration (GPO field = 0x10 or 0x90) . . . . . . . . . . . . 13
WIP Writing in Progress configuration (GPO field = 0x20 or 0xA0) . . . . 14
MIP NDEF Message writing in Progress configuration
(GPO field = 0x30 or 0xB0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
INT Interrupt configuration (GPO field = 0x40 or 0xC0) . . . . . . . . . . . . . 16
State Control configuration (GPO field = 0x50 or 0xD0) . . . . . . . . . . . . 17
RF busy configuration (GPO field = 0x60 or 0xE0) . . . . . . . . . . . . . . . . 18
Field detect configuration (GPO field = 0x70 or 0xF0) . . . . . . . . . . . . . . 19
ST25TA02K-D memory management . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Read and write access rights to the NDEF File . . . . . . . . . . . . . . . . . . . . 23
State of the Read and Write access rights . . . . . . . . . . . . . . . . . . . . . . . 23
Changing the read access right to NDEF files . . . . . . . . . . . . . . . . . . . . 24
Changing the write access right to NDEF files . . . . . . . . . . . . . . . . . . . 25
Communication mechanism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2/66 DocID027817 Rev 5
ST25TA02K-D
Contents
Structure of the command sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
C-APDU: payload format of a command . . . . . . . . . . . . . . . . . . . . . . . . 31
R-APDU: payload format of a response . . . . . . . . . . . . . . . . . . . . . . . . 31
NFC Forum Type 4 Tag protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
NDEF Tag Application Select command . . . . . . . . . . . . . . . . . . . . . . . . 36
Capability Container Select command . . . . . . . . . . . . . . . . . . . . . . . . . . 36
NDEF Select command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
System File Select command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
ReadBinary command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
UpdateBinary command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
ISO/IEC 7816-4 commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Change Reference Data command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Enable Verification Requirement command . . . . . . . . . . . . . . . . . . . . . . 43
Disable Verification Requirement command . . . . . . . . . . . . . . . . . . . . . 44
ST proprietary command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
ExtendedReadBinary command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
EnablePermanentState command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
UpdateFileType command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
SendInterrupt command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
StateControl command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Specific RF command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Anticollision command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
RATS command and ATS response . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
PPS command and response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Anticollision and Device Activation command set for the RF interface . . 53
DocID027817 Rev 5 3/66
4
Contents
ST25TA02K-D
Applicative command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Functional procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Selection of an NDEF message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Reading of an NDEF message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Reading a locked NDEF file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Reaching the read-only state for an NDEF file . . . . . . . . . . . . . . . . . . . . . 55
Creating or Updating an NDEF file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Changing a File Type Procedure (applicable only on file 0x0001) . . . . . . 55
UFDFPN8 package information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
UFDFPN5 package information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
4/66 DocID027817 Rev 5
ST25TA02K-D
List of tables
List of tables
DocID027817 Rev 5 5/66
6
List of tables ST25TA02K-D
6/66 DocID027817 Rev 5
ST25TA02K-D
List of figures
List of figures
UFDFPN5 - 5-lead, 1.7 × 1.4 mm, 0.55 mm thickness package outline. . . . . . . . . . . . . . . 63
DocID027817 Rev 5 7/66
7
Functional description ST25TA02K-D
The ST25TA02K-D device is a dynamic NFC/RFID tag that can be accessed from the RF interface. The RF interface is based on the ISO/IEC 14443 Type A standard. The
ST25TA02K-D is compatible with the NFC Forum Type 4 Tag specifications and supports all corresponding commands.
Figure 1 displays the block diagram of the ST25TA02K-D device.
Figure 1. ST25TA02K-D block diagram
3RZHU
PDQDJHPHQW
XQLW h/ΘƐLJƐƚĞŵ
ĂƌĞĂ
5)LQWHUIDFH
EDVHGRQ
,62,(&
7\SH$
VWDQGDUG
$&
$&
$QDORJ)URQWHQG
EDVHGRQ
,62,(&
7\SH$VWDQGDUG
,QWHUQDOWXQLQJ
FDSDFLWDQFH hƐĞƌŵĞŵŽƌLJ
*32
9
66
'LJLWDOXQLW
1)&)RUXP
7\SH7DJ
SURWRFRO
06Y9
8/66 DocID027817 Rev 5
ST25TA02K-D Functional description
Figure 2. Applicative schematic example
N
9
''
$&
5)
DQWHQQD
*32
$&
9
66
677$.'
,2
0LFURFRQWUROOHU
069
1. Decoupling capacitor
Signal name
Table 1. Signal names
Function
AC0, AC1
V
SS
GPO
Antenna coils
Ground
Interrupt output
(1)
1. An external pull-up > 4.7 k Ω is required.
Figure 3. 8-pin package connections
1&
$&
$&
9VV
1&
*32
1&
1&
Direction
-
-
Open drain output
(1)
06Y9
1. See
Section 13: Package information for package dimensions, and how to identify pin 1.
Figure 4. 5-pin package connections
*32
9VV
$&
$%&'
;<=:
7RSYLHZ
PDUNLQJVLGH
1&
9VV
$&
%RWWRPYLHZ
SDGVVLGH
1. See
Section 13: Package information for package dimensions, and how to identify pin 1.
06Y9
DocID027817 Rev 5 9/66
19
Functional description ST25TA02K-D
The ST25TA02K-D has just one functional mode available (see Table 2 ).
Mode
Tag mode
Supply source
Table 2. Functional mode
Comments
RF field only
The RF interface is connected, GPO Open drain transistor request an external Pull-up (>4.7 KOhm) to operate.
The ST25TA02K-D is supplied by the RF field and can communicate with an RF host (RFID reader or an NFC phone). The User memory can be accessed by the RF commands.
10/66 DocID027817 Rev 5
ST25TA02K-D Signal descriptions
2.1 Antenna coil (AC0, AC1)
These inputs are used to connect the device to an external coil exclusively. It is advised not to connect any other DC or AC path to AC0 or AC1.
When correctly tuned, the coil is used to access the device using NFC Forum Type 4 commands.
2.2 Ground )
V
SS
, when connected, is the reference for the GPO and the other pads, even AC0 and AC1.
DocID027817 Rev 5 11/66
19
Signal descriptions
2.3 General Purpose Output (GPO)
ST25TA02K-D
The GPO pad is an open drain pad and a external pull-up resistor shall be connected to it.
This pad is a configurable output signal, driven a low level when configured event occurs, otherwise it remains in an high impedance state. Its behavior is consistent with the RF session activated and with the mode chosen by the user.
The user can select one of these configurations
(a)
:
• SessionOpen: an RF session is ongoing.
• MIP (NDEF Message updating In Progress): the RF host is writing an NDEF length different from 0x0000. This mode can be used to detect when the RF host changes the
NDEF message as defined by the NFC Forum.
• WIP (Writing In Progress): the ST25TA02K-D is executing a writing operation.
• INT (interrupt): the RF host can force the ST25TA02K-D to send an alternate pulse on the GPO pin.
• State mode: the RF host can control the state of the GPO pad during the RF session.
• RF busy: an RF host is communicating with the ST25TA02K-D.
• Field detection: the RF field is sufficient to establish an RF communication with the
ST25TA02K-D.
GPO configuration byte can be locked, by setting its Most Significant Bit to 1 (1xxx 0000 b).
Once locked, this byte cannot be changed anymore.
12/66 a. See
Table 65: GPO timings measurement for more details.
DocID027817 Rev 5
ST25TA02K-D Signal descriptions
When the GPO is configured as "Session Open", it goes to the low state when an RF session is ongoing (see
An RF session is taken when ST25TA02K-D receives a valid Select Application. The session is released when:
• ST25TA02K-D receives a valid Deselect command
• RF field becomes OFF
GPO is driven low after a delay ( 1.
) when the session is open.
GPO is released after a delay (
) when the session is released.
Figure 5. GPO configured as Session Open (GPO field = 0x10 or 0x90)
5)FKDQQHO
*32DV
6HVVLRQ2SHQ
5)6HVVLRQ 5)6HVVLRQ
069
1. CmdEOFtoGPlow (RF command End of frame to GPORF Session pad low)
2. CmdEOFtoGPHZ (RF command End of frame to GPORF Session pad HZ)
DocID027817 Rev 5 13/66
19
Signal descriptions
2.3.2
ST25TA02K-D
WIP Writing in Progress configuration (GPO field = 0x20 or 0xA0)
When the GPO is configured as "WIP", it goes to the low state during an RF writing operation (see
During an RF session, when ST25TA02K-D updates a file, GPO is driven low after a delay
( 1.
) following the beginning of the correspondent UpdateBinary command execution.
GPO will remain low during the writing time ( 2.
), before being released.
Figure 6. GPO configured as WIP (GPO field = 0x20 or 0xA0)
5)FKDQQHO
*32DV:,3
8SGDWH
FRPPDQG
(QGRIZULWLQJ
RSHUDWLRQ
$Q\RWKHU
FRPPDQG
069
1. CmdEOFtoGPlow (RF Command End of frame to GPO low)
2. Writing time duration
14/66 DocID027817 Rev 5
ST25TA02K-D Signal descriptions
NDEF
(GPO field = 0x30 or 0xB0)
When the GPO is configured as MIP, its state goes to the low state when the RF host writes the NDEF length to another value than 0x0000 (see
During an RF session, when ST25TA02K-D changes an NDEF file and updates the NDEF length with a value different from 0x0000, GPO is driven low after a delay ( 1.
) following the beginning of the correspondent UpdateBinary command execution.
GPO will remain low during the writing time ( 2.
), before being released.
5)FKDQQHO
Figure 7. GPO configured as MIP (GPO field = 0x30 or 0xB0)
8SGDWHWKH1'()
OHQJWK [
677$[.'
UHVSRQVH
$Q\RWKHU
FRPPDQG
*32DV0,3
069
1. CmdEOFtoGPlow (RF command End of frame to GPO low)
2. Writing time duration
DocID027817 Rev 5 15/66
19
Signal descriptions ST25TA02K-D
The RF host can send a negative pulse on the GPO pad. The GPO pad goes to high state at the end of the command and goes to the high state at the end of the ST25TA02K-D response (see
).
During an RF session, when ST25TA02K-D receives a valid Interrupt command,
ST25TA02K-D GPO pin is driven low after ( 1.
). Then GPO pin is released at the end of the response (
).
Figure 8. GPO configured as INT (GPO field = 0x40 or 0xC0)
5)FKDQQHO
6HQG
,QWHUUXSW
677$[.'
UHVSRQVH
$Q\RWKHU
RSHUDWLRQ
*32DV,17
069
1. CmdEOFtoGPlow (RF command End of frame to GPO low)
2. RespEOFGPlow
16/66 DocID027817 Rev 5
ST25TA02K-D
2.3.5
Signal descriptions
State Control configuration (GPO field = 0x50 or 0xD0)
When the GPO is configured as State Control, the RF host can control the state of the GPO by sending a dedicated command (see
During an RF session, the ST25TA02K-D can control the GPO pin. After receiving a valid reset GPO command, GPO pin is driven low after a delay ( 1.
). GPO will be released after a valid Set command or after a Power off.
Figure 9. GPO configured as State Control (GPO field = 0x50 or 0xD0)
5)FKDQQHO
5HVHW*32
FRPPDQG
$Q\RWKHU
FRPPDQG
6HW*32
FRPPDQG
*32DV
6WDWH&RQWURO
069
1. CmdEOFtoGPlow (RF Reset GPO command End of frame to GPO low)
2. CmdEOFtoGPHZ (RF Set GPO command End of frame to GPO HZ)
DocID027817 Rev 5 17/66
19
Signal descriptions
2.3.6 RF busy configuration (GPO field = 0x60 or 0xE0)
ST25TA02K-D
When the GPO is configured as RF busy, the GPO goes to the low state, both when the
ST25TA02K-D is processing an RF command or when an RF session is ongoing (see
).
When an RF field is present, GPO is driven low after a delay ( 1.
) when ST25TA02K-D detects the first command. If the RF session is ongoing and ST25TA02K-D receives a notsupported command, GPO remains low. It will be released only at the end of the RF
Figure 10. GPO configured as RF busy (GPO field = 0x60 or 0xE0)
5)FKDQQHO
*32DV
5)EXV\
5)FRPPDQGQRW
VXSSRUWHG
6HQV5HT
6HQV5HV
5)FRPPDQG
6/3B5(4RU
6'(6RU
EDGFRPPDQG
RU5))LHOG2))
069
1. CmdSOFtoGPlow (RF command Start of frame to GPO low)
2. CmdEOFtoGPHZ (RF command End of frame to GPO HZ)
18/66 DocID027817 Rev 5
ST25TA02K-D Signal descriptions
When the GPO is configured as Field detect, the GPO goes to the low state when
ST25TA02K-D detects an RF Field (see
When an RF field is present, GPO is driven low after a delay when ST25TA02K-D detects this field. Whatever the activity during the RF field detection (communication with the reader or not), GPO will stay low. It will be released when ST25TA02K-D leaves the RF field.
Figure 11. Field detect (GPO field = 0x70 or 0xF0)
+
PLQ
5)ILHOG
*32
W
)'(721
W
)'(72))
+=
9
66
069
DocID027817 Rev 5 19/66
19
ST25TA02K-D memory management
3 ST25TA02K-D memory management
ST25TA02K-D
The ST25TA02K-D supports the NDEF Tag Application as defined in the NFC Forum Type 4
Tag. The ST25TA02K-D is composed of three files:
• a Capability Container (CC) file
• an NDEF file
• a System file: this file is an ST-proprietary file
The System file contains some information on the configuration of the ST25TA02K-D device. The CC file gives some information about the ST25TA02K-D itself and the NDEF file. The NDEF file contains the User data.
The file identifier is the value used in the Select command to select a file.
File identifier
0xE101
0xE103
0x0001
System file
CC file
NDEF file
Table 3. File identifier
Meaning
The CC file gives some information about the ST25TA02K-D and the NDEF file. This file is a read-only file for the RF host and cannot be modified by issuing a write command.
The T field, Read Access and Write Access fields can be changed by the RF host by issuing a specific process (refer to
Section 7: Functional procedures
).
File offset
0x0000
0x0002
0x0003
0x0005
Table 4. CC file layout for 1 NDEF file
Meaning Value
Length CC file
Mapping version
(1)
Maximum number of bytes that can be read
0x000F
0x20 or 0x10
0x00FF
Maximum number of bytes that can be written 0x0036
Comments
15 bytes
V 2.0 or V 1.0
255 bytes
54 bytes
20/66 DocID027817 Rev 5
ST25TA02K-D ST25TA02K-D memory management
File offset
0x0007
0x0008
0x0009
0x000B
0x000D
0x000E
Table 4. CC file layout for 1 NDEF file (continued)
Meaning Value
NDEF file control TLV
0x04
(2)
0x06
0x0001
0x0100
0x00
(2)
0x00
(2)
Comments
T field
L field
FileID
Maximum NDEF file size in Byte
Read access
Write access
1. According to the reader command format ST25TA02K-D will automatically align to the corresponding NFC
Forum version.
2. Delivery state.
The NDEF file contains the NDEF message which contains the User data. The RF host can read and write data inside the file. The first two bytes named NDEF Message Length define the size of the NDEF message. The NDEF Message Length shall be managed by the application and the ST25TA02K-D device does not check if its value is relevant vs the data written by the RF host. The ST25TA02K-D device uses the NDEF Message Length, e. g. the standard read can be processed only inside the NDEF message; otherwise, the
ST25TA02K-D device returns an error code. For more details about the read command, refer to
Section 5.6.7: ReadBinary command .
File offset
0x0000
0x0004
...
...
...
0x00FC
Byte 0
Table 5. NDEF file layout
Byte 1 Byte 2
NDEF Message Length
User data User data
...
...
...
...
...
...
...
...
User data
User data
...
...
...
...
Byte 3
User data
User data
...
...
...
User data
DocID027817 Rev 5 21/66
26
ST25TA02K-D memory management ST25TA02K-D
The system file specifies the configuration of the ST25TA02K-D. Table 6
lists the different fields.
File offset Field name
Table 6. Field list
No. of bytes Read access Write access Delivery state
0x0000 Length system file
0x0002 GPO Config
0x0003 Event Counter
(3)
Config
0x0004
20 bits counter
(MS nibble 0x0)
0x0007 Product version
2
1
1
3 yes yes yes yes
yes
(1) yes
(1) none
0x0012
0x70
(2)
0x00
0x000000
0x0008 UID
0x000F Memory Size - 1
0x0011 IC reference code
1
7
2
1 yes yes yes yes none none none none
0x13
(4)
0x02F2 xx xx xx xx xx
(5)
0x00FF
0xF2
1. Configuration bytes can be locked by setting the Most significant bit to 1. Once locked, these bytes cannot be changed anymore.
2. Field detect as default GPO configuration.
3. Counter is not activated by default.
4. ST reserved.
5. x values are defined by ST to ensure UID unicity.
Table 7. Details about the GPO field b7 b6-b4 b3-b0 File offset
0x0002
GPO config lock bit:
0b0: unlocked
0b1: locked
GPO configuration:
0b000: Not used
0b001: Session opened
0b010: WIP
0b011: MIP
0b100: Interrupt
0b101: State Control
0b110: RF Busy
0b111: Field Detect
0b0000 ST Reserved
22/66 DocID027817 Rev 5
ST25TA02K-D ST25TA02K-D memory management
Warning: When GPO config lock bit is set to “1”, the whole byte cannot be changed anymore.
3.2
3.2.1
File offset
0x0003
Counter config lock bit:
0b0: unlocked
0b1: locked
0b00000: ST reserved
Counter enable:
0b0: disable
0b1: enable
Counter increment:
0b0: on Read
0b1: on Write
Table 8. Details about the Counter config field b7 b6-b2 b1 b0
Read and write access rights to the NDEF File
The NDEF file can be locked for read or write accesses. It is also protected by a 128-bit password that the host shall present before accessing the NDEF file. There are two 128-bit passwords, one for the read access and the other one for the write access.
An NDEF file can be permanently locked for read or write accesses. Thus, the host cannot access the NDEF file.
The read password shall be sent to the ST25TA02K-D device before reading a read-locked
NDEF file.
The write password shall be present on the ST25TA02K-D device before writing a write-locked NDEF file. The write password shall be sent to change the read or write access. The read or write access right is defined for the NDEF file.
State of the Read and Write access rights
Two bytes in the CC file are used to define the Read and Write access rights to the NDEF file. For more details, refer to
Section 3.1.2: CC file layout .
Value
Table 9. Read access right
Meaning
0x00
0x80
0xFE
Read access without any security
Locked
(1)
Read not authorized
1. The read password shall be sent before reading in the NDEF file.
DocID027817 Rev 5 23/66
26
ST25TA02K-D memory management ST25TA02K-D
Value
Table 10. Write access right
Meaning
0x00
0x80
0xFF
Write access without any security
Locked
(1)
Write not authorized
1. The write password shall be sent before writing in the NDEF file.
The state 0xFF and 0xFE cannot be changed by using the Read or Write passwords.
The state diagram in
Figure 12 shows how to change the access right to read an NDEF file.
Figure 12. Changing the read access right to an NDEF file
[
/RFNWKH1'()ILOH
8QORFNWKH1'()ILOH
[ [)(
3HUPDQHQWO\ORFNWKH1'()ILOH
1. See the procedure to lock the read access ( Section 7.4: Locking an NDEF file ).
2. See the procedure to unlock the read access (
Section 7.5: Unlocking an NDEF file
).
3. See the procedure to permanently lock the read access.
4. Proprietary state, not defined by NFC Forum Type 4 Tag.
069
24/66 DocID027817 Rev 5
ST25TA02K-D ST25TA02K-D memory management
The state diagram on
shows how to change the write access right to an NDEF file.
Figure 13. Changing the write access right to an NDEF file
[
/RFNWKH1'()ILOH
8QORFNWKH1'()ILOH
3.3
[
3HUPDQHQWO\ORFNWKH1'()ILOH
[))
069
1. See the procedure to lock the write access.
2. See the procedure to unlock the write access.
3. See the procedure to permanently lock the write access (
Section 7.6: Reaching the read-only state for an
4. Proprietary state, not defined by NFC Forum Type 4 Tag.
Access right life time
The access right life time is validated while the NDEF file is selected or until the end of the
RF session. Once the read or write access right is granted, the host can send one or more
ReadBinary or UpdateBinary commands.
At the end of a session or when the host selects another file, the read and write access rights are initialized.
Note:
The NDEF file passwords protect the read or write access from an RF interface from/to an
NDEF file.
Two NDEF file passwords are available for each NDEF file:
• Read password
• Write password
The length of a password is 128 bits (16 bytes).
The delivery state for all passwords = 0x00000000000000000000000000000000.
DocID027817 Rev 5 25/66
26
ST25TA02K-D memory management ST25TA02K-D
A 20 bits counter can track the read or write events on the NDEF file.
It benefits from an anti-tearing mechanism, that ensures the consistency of the counter, even if there has been an electrical problem during its increment.
The value of the Read/Write counter can be checked by any application, by reading suitable bytes in System file (see
).
If enabled, the Read/Write counter will be incremented on first event (exclusively Read or
Write) which is performed on the NDEF File, inside an RF session (an RF session is entered when ST25TA02K-D receives a valid "Select Application" command).
The counter is reset when it is disabled.
Apart from these procedures, there is no way to act on the value of this counter.
The Read/Write counter can be configured through a specific byte in System file (see
This configuration byte allows to:
• Enable or disable this counter
• Define if the counter must be incremented on a read or write sequence
• Definitively lock this configuration byte
Warning: Once this configuration byte is locked, it cannot be changed anymore: the counter will behave accordingly.
If enabled, the Read/Write counter will have an impact on the execution time of the event which is countered: the counter increment needs some write cycles of specific EEPROM cells automatically managed by ST25TA02K-D, which increase the total time before the response is sent to the reader.
As a consequence, an S(WTX) request can be issued on the command that will increment
the counter (see Section 5.4: S-Block format
).
26/66 DocID027817 Rev 5
ST25TA02K-D Communication mechanism
4.1
This section describes the principle of communication between an RF host and the
ST25TA02K-D device.
Master and slave
The ST25TA02K-D acts as a slave device on the RF channel and therefore waits for a command from the RF host before sending its response.
The RF host shall generate the RF field and the RF commands.
DocID027817 Rev 5 27/66
60
RF command sets
5 RF command sets
ST25TA02K-D
This section describes the ST25TA02K-D command sets that can be issued by the RF host.
There are three command families:
• the NFC Forum Type 4 Tag command set
• the ISO/IEC 7816-4 command set
• the proprietary command set
The NFC Forum Type 4 Tag command set and the ISO/IEC 7816-4 command set use the I-
Block format. For more details about the I-Block format, refer to Section 5.2: I-Block format .
Two other command formats exist:
• the commands using the R-Block format
• the commands using the S-Block format
For more details about these formats, refer to
and to
This section gives a brief description of the RF host commands. The format of these command sets is the I-Block format.
Table 11 lists the RF command sets.
Family command set
NFC Forum
Type 4 Tag
ST proprietary
Table 11. RF command sets
Command name
Class byte
Instruction code
NDEF Tag Application Select
CC select
NDEF select
System select
ReadBinary
UpdateBinary
0x00
0x00
0x00
0x00
0x00
0x00
0xA4
0xA4
0xA4
0xA4
0xB0
0xD6
Verify
ISO/IEC 7816-4
ChangeReferenceData
EnableVerificationRequirement
DisableVerificationRequirement
EnablePermanentState
ExtendedReadBinary
UpdateFileType
SendInterrupt
StateControl
0x00
0x00
0x00
0x00
0xA2
0xA2
0xA2
0xA2
0xA2
0x20
0x24
0x28
0x26
0x28
0xB0
0xD6
0xD6
0xD6
Brief description
NDEF Tag Application Select
Selects the CC file
Selects the NDEF file
Selects the system file
Reads data from file
Writes or erases data to an NDEF file
Checks the right access of an NDEF file or sends a password
Changes a Read or write password
Activates the password security
Disables the password security
Enables the Read Only or Write Only security state
Reads data from file
Sets file type to NDEF or proprietary
Generates a pulse on the GPO pin
Drives the state of the GPO pin
28/66 DocID027817 Rev 5
ST25TA02K-D
5.1
RF command sets
Structure of the command sets
The exchange of data between the RF host and the ST25TA02K-D uses three kinds of data formats, called blocks:
• I-Block (Information block): to exchange the command and the response
• R-Block (Receive ready block): to exchange positive or negative acknowledgment
• S-Block (Supervisory block): to use either the Deselect command or the Frame Waiting eXtension (WTX) command or response
This section describes the structure of I-Block, R-block and S-Block. This format is used for the application command set.
The I-Block is used to exchange data between the RF host and the ST25TA02K-D. It is composed of three fields.
Table 12 details the I-Block format.
Name
PCB
Length 1 byte
PCB field
DID field (optional)
RF host to ST25TA02K-D: C-APDU
ST25TA02K-D to RF host: R-APDU
2 CRC bytes
Table 12. I-Block format
SoD Payload
DID
1 byte
-
1 to 251 bytes
EoD
CRC
2 bytes
DocID027817 Rev 5 29/66
60
RF command sets
Note:
ST25TA02K-D b7-b6
Table 13. PCB field of the I-Block format b5 b4
0b00 0 0
I-Block
RFU
Must be set to 0
DID field is present, if bit is set
Must be set to 0
Must be set to 1
Block number (1)
1. Follow ISO 14443_4 Block numbering rules (see note) b3
X b2
0 b1
1 b0
X
Block numbering rules:
Reader rules:
Rule A: The Reader block number shall be initialized to 0.
Rule B: When an I-block or an R(ACK) block with a block number equal to the current block number is received, the Reader shall toggle the current block number before optionally sending a block to the
ST25TA02K-D.
ST25TA02K-D rules:
Note:
Note:
Rule C: The ST25TA02K-D block number shall be initialized to 1 at activation.
Rule D: When an I-block is received, the ST25TA02K-D shall toggle its block number before sending a block.
The ST25TA02K-D may check if the received block number is not in compliance with Reader rules to decide neither to toggle its internal block number nor to send a response block.
Rule E: When an R(ACK) block with a block number not equal to the current
ST25TA02K-D block number is received, the ST25TA02K-D shall toggle its block number before sending a block.
There is no block number toggling when an R(NAK) block is received.
When the RF host sends a command to the ST25TA02K-D the format of the payload is the
C-APDU.
When the ST25TA02K-D sends a command to the RF host, the format of the payload is the
R-APDU.
30/66 DocID027817 Rev 5
ST25TA02K-D
5.2.1
RF command sets
C-APDU: payload format of a command
The C-APDU format is used by the RF host to send a command to the ST25TA02K-D.
Table 14 describes its format.
Name
CLA INS
Table 14. C-APDU format
Payload field
P1 P2 L
C
1 byte Length 1 byte 1 byte 1 byte 1 byte
Class byte
- 0x00: standard command
- 0xA2: ST command (1)
Instruction byte
Param Byte 1
Param Byte 2
Number of bytes of the Data field
Data bytes
Number of bytes to be read in the ST25TA02K-D memory
1. See
Data
Lc byte
Le
1 byte the ST25TA02K-D uses the I-Block format to reply to a command that used the I-Block format. This format is described in
Name
Table 15. R-APDU format
Payload field
Data (optional)
Le byte
SW1
1 byte Length
Data
Status byte 1
Status byte 2
SW2
1 byte
DocID027817 Rev 5 31/66
60
RF command sets ST25TA02K-D
The R-Block is used to convey positive or negative acknowledgment between the RF host and the ST25TA02K-D.
NFC frame
Table 16. R-Block format
SoD
PCB DID
Length 1 byte
R(ACK) without the DID field: 0xA2 or 0xA3
R(ACK) with the DID field: 0xAA or 0xAB
R(NAK) without the DID field: 0xB2 or 0xB3
R(NAK) with the DID field: 0xBA or 0xBB
DID field (optional)
-
2 CRC bytes
1 byte
-
Payload
0 byte
EoD
CRC
2 bytes
There are two kinds of R-Blocks:
• R(ACK): the acknowledgment block sent by the RF host or by the ST25TA02K-D
• R(NAK): the non-acknowledgment block sent by the RF host b7-b6
0b10
R-Block
Must be set to 1.
0: ACK
1: NAK
0: DID field is not present
1: DID field is present
Must be set to 0
Must be set to 1
Block number
Table 17. R-Block detailed format b5 b4 b3 b2
1 X X 0 b1
1 b0
X
32/66 DocID027817 Rev 5
ST25TA02K-D RF command sets
The S-Block is used to exchange control information between a reader and a contactless tag.
NFC frame
Table 18. S-Block format
PCB
SoD
DID
-
Payload
EoD
CRC
Length 1 byte 1 byte 1 byte 2 bytes
0xC2: for S(DES) when the DID field is not present
0xCA: for S(DES) when the DID field is present
0xF2: for S(WTX) when the DID field is not present
0xFA: for S(WTX) when the DID field is present
DID field (optional)
WTX field (optional)
(1)
2 CRC bytes
1. This field is present when b5-b4 bits are set to 0b11 (S-Block is a WTX). See
Table 19: S-Block detailed format
.
There are two requests using the S-Block format:
• S(DES): the deselect command
• S(WTX): the Waiting Frame eXtension command or response.
A Waiting Time eXtension request occurs in RF when the operating time needed by
ST25TA02K-D is greater than 19.2 ms.
The WTX field indicates the increase time factor to be used in this command execution
(FDTtemp = WTX * 19.2 ms). WTX depends on FWI.
Table 19. S-Block detailed format b5-b4 b3 b2
X X 0 b1
1 b0
0 b7-b6
0b11
S-Block
0b00: Deselect
0b11: WTX
0: DID field is not present
1: DID field is present
Must be set to 0
Must be set to 1
Must be set to 0
DocID027817 Rev 5 33/66
60
RF command sets
Note:
ST25TA02K-D
After receiving the deselect command, the session is released and ST25TA02K-D enters the Standby power mode.
In response to a RATS command, ST25TA02K-D returns FWI parameter (default frame waiting time used); when ST25TA02K-D needs more time for a command execution, it requests a frame waiting time extension by responding 0xF2 0xWTX (Request waiting time =
FWI * WTX). If the reader accepts the ST25TA02K-D request, it acknowledges it by sending the command 0xF2 0xWTX. The frame waiting time becomes FWI * WTX for the current command only.
5.5
5.6
CRC of the RF frame
The two CRC bytes check the data transmission between the RF host and the
ST25TA02K-D. For the RF frame, the CRC is computed on all the data bits in the frame, excluding parity bits, SOF and EOF, and the CRC itself.
The CRC is as defined in ISO/IEC 13239. The initial register content shall be 0x6363 and the register content shall not be inverted after calculation.
NFC Forum Type 4 Tag protocol
5.6.2
ST25TA02K-D command set is built to easily support the NFC Forum Type 4 Tag protocol.
Command name
NDEF Tag Application Select
Capability Container Select
NDEF Select
System File Select
ReadBinary
UpdateBinary
Table 20. Command set overview
Brief description
Select the NDEF Tag Application
Select the capability container (CC) file using the Select command
Select the NDEF file using the Select command.
Select the system file using the Select command.
Read data from a file
Write new data to a file
Status and error codes
This section lists the status and the error code of the ST25TA02K-D.
Value
Table 21. Status code of the ST25TA02K-D
SW1 SW2 Comment
0x90 0x00 Command completed successfully
34/66 DocID027817 Rev 5
ST25TA02K-D
Length
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
RF command sets
Table 22. Error codes of the ST25TA02K-D
SW1 SW2
Comment
1 byte 1 byte
0x62
0x63
0x63
0x65
0x67
0x69
0x69
0x69
0x6A
0x6A
0x6A
0x6A
0x6D
0x6E
0x82
0x00
0xCX
0x81
0x00
0x81
0x82
0x84
0x80
0x82
0x84
0x86
0x00
0x00
End of file or record reached before reading Le bytes
Password is required
Password is incorrect, X additional retries allowed (X can take values 0,
1 and 2)
Unsuccessful updating
Wrong frame length
Command is incompatible with the file structure
Security status not satisfied
Reference data not usable
Incorrect parameters Le or Lc
File or application not found
File overflow (Lc error)
Incorrect P1 or P2 values
INS field not supported
Class not supported
DocID027817 Rev 5 35/66
60
RF command sets ST25TA02K-D
5.6.3 NDEF Application Select command the RF host shall send this command to activate the NDEF Tag Application.
To activate the NDEF Tag Application, the RF host sends the Select command (see
Table 23 ) in addition to the sequence defined in the NFC Forum digital protocol.
Table 23 defines the C-APDU of the Select command to select the NDEF Tag Application
(called NDEF Tag Application Select).
-
Name
Table 23. C-APDU of the NDEF Tag Application Select command
CLA INS P1 P2 Lc Data
0x00 0xA4 0x04 0x00 0x07
0xD27600
00850101
Class byte
Select instruction code
P1 field
P2 field
Number of bytes of data
Application ID
Le field
Le
0x00
Table 24 defines the R-APDU of the NDEF Tag Application Select command.
Length
Value
Value
Value
Table 24. R-APDU of the NDEF Tag Application Select command
Data SW1 SW2 Comment
-
-
-
1 byte
0x90
0x6A
0x6D
1 byte
0x00
0x82
0x00
-
Command completed
NDEF Tag Application not found
Class not supported
Note:
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
The RF host uses the Capability Container Select procedure to select the capability container (CC) file.
The CC file is selected when this command returns "command completed" in the R-APDU.
Table 25 defines the C-APDU of the Select command to select the CC file (called Capability
Container Select).
36/66 DocID027817 Rev 5
ST25TA02K-D
Note:
RF command sets
Name
Table 25. C-APDU of the Capability Container Select command
CLA
-
Class byte
0x00
Select instruction code
P1 field
P2 field
Number of bytes of data
CC file ID
(empty field)
INS
0xA4
P1
0x00
P2
0x0C
Lc
0x02
Data
0xE103
Table 26 defines the R-APDU of the CC Select command.
Length
Value
Value
Value
Table 26. R-APDU of the Capability Container Select command
Data SW1 SW2 Comment
-
-
-
1 byte
0x90
0x6A
0x6D
1 byte
0x00
0x82
0x00
-
Command completed
File or application not found
Class not supported
Le
-
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
The RF host uses the NDEF Select command to select the NDEF file.
The NDEF file is selected when this command returns "command completed" in the
R-APDU.
Table 27 defines the C-APDU of the Select command to select the NDEF file
(called NDEF Select).
Name CLA
Table 27. C-APDU of the NDEF Select command
0x00
Class byte
Select instruction code
P1 field
P2 field
Number of bytes of data
0x0001: NDEF file
(empty field)
INS
0xA4
P1
0x00
P2
0x0C
Lc
0x02
Data
0x0001
Le
-
DocID027817 Rev 5 37/66
60
RF command sets
Table 28 defines the R-APDU of the NDEF Select command.
Length
Value
Value
Data
Table 28. R-APDU of the NDEF Select command
SW1 SW2 Comment
-
-
-
1 byte
0x90
0x6A
1 byte
0x00
0x82
-
Command completed
File or application not found
ST25TA02K-D
Note:
5.6.6
Note:
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
System File Select command
The RF host uses this command to select the system file.
The System file is selected when this command returns “command completed” in the
R-APDU.
Table 29 defines the C-APDU of the command to select the System file (called System
Select).
Name
Table 29. C-APDU of the System File Select command
CLA
-
Class byte
0x00
Select instruction code
P1 field
P2 field
Number of bytes of data
System file ID
(empty field)
INS
0xA4
P1
0x00
P2
0x0C
Lc
0x02
Data
0xE101
Le
-
Table 30 defines the R-APDU of the System File Select command.
Length
Value
Value
Table 30. R-APDU of the System File Select command
Data SW1 SW2 Comment
-
-
1 byte
0x90
0x6A
1 byte
0x00
0x82
-
Command completed
System file not found, no data is returned
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
38/66 DocID027817 Rev 5
ST25TA02K-D RF command sets
Note:
On receiving the ReadBinary command, the ST25TA02K-D reads the requested memory field and sends back its value in the R-APDU response.
Before sending a ReadBinary command, a file shall be selected by using a Select command.
The Response of the ReadBinary command is successful when the data to be read is within the selected file
(a)
, that is when the sum of P1-P2 and Le fields is equal to or lower than the selected file length.
Table 31 defines the ReadBinary command.
Name
Table 31. C-APDU of the ReadBinary command
CLA INS P1 and P2
0x00
Class byte
Read instruction code
0xB0
Offset in the file selected
(empty field)
(empty field)
Number of bytes to read between
0x01 ≤ Le ≤ max(Selected File length, 0xFFh)
2 bytes
Lc
-
Data
-
Le
1 byte
Table 32 defines the R-APDU of the ReadBinary command.
Length
Value
Value
Value
Value
Value
Table 32. R-APDU of the ReadBinary command
Data SW1 SW2 Comment
-
Content read
-
-
-
-
1 byte
0x90
0x67
0x69
0x6A
0x6E
1 byte
0x00
0x00
0x82
0x82
0x00
-
Command completed
Wrong length
Security status not satisfied
File or application not found
-
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
a. For more details about CC file, refer to
Section 3.1.2: CC file layout .
For more details about NDEF file, refer to
Section 3.1.3: NDEF file layout
.
For more details about System file, refer to Section 3.1.4: System file layout .
DocID027817 Rev 5 39/66
60
RF command sets ST25TA02K-D
Note:
Note:
On receiving the UpdateBinary command, the ST25TA02K-D writes the data field into the selected file and sends back a status in the R-APDU response. If needed, ST25TA02K-D
will request a timing extension (see Section 5.4
).
Before sending an UpdateBinary command, a file shall be selected by issuing a Select command.
Table 33 defines the UpdateBinary command.
Name
Table 33. C-APDU of the UpdateBinary command
CLA INS P1 and P2 Lc Data
2 bytes 1 byte Lc bytes 0x00
Class byte
Write instruction code
0xD6
Offset in the file selected
Number of bytes of data (0x01 ≤ Lc ≤
Data to write in the ST25TA02K-D memory
(empty field)
Le
-
Length
Value
Value
Value
Value
Value
Value
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
Table 34 defines the R-APDU of the UpdateBinary command.
Table 34. R-APDU of the UpdateBinary command
Data SW1 SW2 Comment
-
-
-
-
-
-
-
1 byte
0x90
0x65
0x67
0x69
0x6A
0x6E
1 byte
0x00
0x81
0x00
0x82
0x82
0x00
-
Command completed
Unsuccessful updating
-
Security status not satisfied
File or application not found
-
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
40/66 DocID027817 Rev 5
ST25TA02K-D
5.7
RF command sets
ISO/IEC 7816-4 commands
The ISO/IEC 7816-4 command set offers some extended features such as the protection of the NDEF file. This command set is used to manage the right access of the NDEF file.
The Verify command has two functions:
1.
Check if a password is required to access to the NDEF file (the LC field = 0x00).
2. Check that the password embedded in the Verify command enables the access to the memory (the Lc field = 0x10 and the password is present).
When the Lc field if equal to 0x00, the verify command returns a success code (0x90 00) provided that the access to the NDEF file does not require a password. When the access to the NDEF file is protected, the response to the Verify command returns an error code
(0x63 00).
When the Lc field equals 0x10, on receiving the Verify command, the ST25TA02K-D compares the requested password with the data contained in the request and reports whether the operation has been successful in the response.
Before sending this command, an NDEF file shall be selected by issuing the NDEF Select command. Thus, this command checks the right access condition of the last NDEF file selected.
After a successful command, an access is granted for the whole NDEF file.
Table 35 defines the Verify command.
Name CLA
Table 35. Verify command format
INS P1 and P2
0x00 0x20
Class byte
Instruction code
Password identification
0x0001: Read NDEF password transmit
0x0002: Write NDEF password transmit
Other: RFU
(1)
0x00: the password is not present
0x10: the password is present in the data field
Password
(empty field)
2 bytes
1. Return ERROR code when used.
Lc
1 byte
Data
Lc bytes
Le
-
DocID027817 Rev 5 41/66
60
RF command sets
Note:
5.7.2
ST25TA02K-D
Table 36 defines the R-APDU of the Verify command.
Data
Table 36. R-APDU of the Verify command
SW1 SW2 Comment
Length
Value
Value
Value
Value
Value
Value
Value
-
-
-
-
-
-
-
-
1 byte
0x90
0x69
0x69
0x69
0x6A
0x63
0x63
1 byte
0x00
0x84
0x81
0x82
0x80
0x00
0xCX
(1)
-
Command completed, the password is correct
The conditions of use are not satisfied (e.g. no
NDEF file was selected or Write access equal to
FFh (write lock) or read access equal to FEh (read lock)
Command incompatible with file structure
Security status not satisfied
Incorrect parameter in command data field
A password is required
The password transmitted is incorrect and X encodes the number of further allowed retries.
1. At each session, the RF host can check a password 3 times.
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
Change Reference Data command
The Change Reference Data command replaces the read or write password related to the
NDEF files previously selected. It can be performed only if the security status satisfies the security attributes for this command.
Before sending this command, the verify command with the correct NDEF write password shall be issued. Thus, this command changes the reference data of the NDEF file.
Table 37 defines the Change Reference Data command.
Name
Table 37. Change reference data command format
CLA INS P1 and P2
-
Class byte
Instruction code
0x00 0x24
Password identification
0x0001: Read password transmit
0x0002: Write password transmit
Other: RFU
(1)
0x10: the password is present in the data field
NDEF new file Password
(empty field)
2 bytes
1. Return ERROR code when used.
Lc
0x10
Data
Lc bytes
Le
-
42/66 DocID027817 Rev 5
ST25TA02K-D RF command sets
Length
Value
Value
Value
Value
Value
Value
Value
Table 38 defines the R-APDU of the Change Reference Data command.
Table 38. R-APDU of the Change Reference Data command
Data SW1 SW2 Comment
0 1 byte 1 byte
-
-
-
-
-
-
0x90
0x69
0x65
0x69
0x6A
0x6A
0x6A
0x00
0x81
0x81
0x82
0x80
0x82
0x86
-
Command completed, the access right has been changed
Command is incompatible with the file structure
Unsuccessful updating
Security status not satisfied
Incorrect parameter in file structure
File or application not found
Incorrect P1 or P2 values
Note:
5.7.3
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
Enable Verification Requirement command
The Enable Verification Requirement command activates the protection by password of the
NDEF file. When this command is successful, the read or write access to the NDEF file is protected by a 128-bit password. It can be performed only if the security status satisfies the security attributes for this command.
This command can update the right access of the NDEF file by writing into the EEPROM. In this case, the response timing will be around 5 ms.
Before sending this command, the verify command with the correct NDEF write password shall be issued. Thus, this command changes the access right of the NDEF file.
Table 39 defines the Enable Verification requirement command.
Name
Table 39. Enable Verification Requirement command format
CLA INS P1 and P2
-
Class byte
Instruction code
0x00 0x28 2 bytes
New security attributes
0x0001: Enable the read protection of the NDEF file
0x0002: Enable the write protection of the NDEF file
Other: RFU
(empty field)
(empty field)
(empty field)
Lc
-
Data
-
Le
-
The last five bits identify the password sent in the Verify command.
DocID027817 Rev 5 43/66
60
RF command sets ST25TA02K-D
Table 40 defines the R-APDU of the Enable Verification Requirement command.
Length
Value
Value
Value
Value
Value
Value
Table 40. R-APDU of the Enable Verification Requirement command
Data SW1 SW2 Comment
-
-
-
-
-
0
-
1 byte
0x90
0x69
0x69
0x6A
0x6A
0x6A
1 byte
0x00
0x81
0x82
0x80
0x82
0x86
-
Command completed, the password is correct
Command is incompatible with the file structure
Security status not satisfied
Incorrect parameter in command data field
File or application not found
Incorrect P1 or P2 values
Note:
5.7.4
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
Disable Verification Requirement command
The Disable Requirement command deactivates the protection by password of the NDEF file. When this command is successful, the read or write access to the NDEF file is granted without security requirements. It can be performed only if the security status satisfies the security attributes for this command.
Before sending this command, the verify command with the correct NDEF write password shall be issued. Thus, this command changes the access right of the NDEF file.
This command can update the right access of the NDEF file by writing into the EEPROM. In this case, the response timing will be around 6 ms.
Table 41 defines the Disable Verification Requirement command.
Name
Table 41. Disable Verification Requirement command format
CLA INS P1 and P2
-
Class byte
0x00 0x26 2 bytes
Instruction code
New security attributes
0x0001: Disable the read protection of the NDEF file
0x0002: Disable the write protection of the NDEF file
Other: RFU
(empty filed)
(empty filed)
(empty filed)
Lc
-
Data
-
Le
-
Table 42 defines the R-APDU of the Disable Verification Requirement command.
44/66 DocID027817 Rev 5
ST25TA02K-D
Note:
RF command sets
Length
Value
Value
Value
Value
Value
Value
Value
Table 42. R-APDU of the Disable Verification Requirement command
Data SW1 SW2 Comment
-
-
-
-
-
-
0
-
1 byte
0x90
0x69
0x69
0x6A
0x6A
0x6A
0x65
1 byte
0x00
0x81
0x82
0x80
0x82
0x86
0x81
-
Command completed, the password is correct
Command is incompatible with the file structure
Security status not satisfied
CC file or System file selected
File or application not found
Incorrect P1 or P2 values
Update failed
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
5.8 ST proprietary command set
The RF host can be issued with the command set described in this section.
Upon receiving the ExtendedReadBinary command, the ST25TA02K-D reads the requested memory field and sends back its value in the R-APDU response.
Before sending an ExtendedReadBinary command, a file shall be selected by issuing an
NDEF select command.
The response of the ExtendedReadBinary command will be successful even if the data to be read is beyond the NDEF message. The command returns an error code if the data to be read goes beyond the end of the file.
Name
Table 43. C-APDU of the ExtendedReadBinary command
CLA INS P1 and P2
-
ST Class byte
0xA2
Read instruction code
Offset in the file selected
0xB0 2 bytes
(empty field)
(empty field)
Number of bytes to read between 0x01 ≤ Le ≤ 0xFF
Lc
-
Data
-
Le
1 byte
Table 44 defines the R-APDU of the read binary command.
DocID027817 Rev 5 45/66
60
RF command sets
Note:
ST25TA02K-D
Length
Value
Value
Value
Value
Value
Table 44. R-APDU of the ExtendedReadBinary command
Data SW1 SW2 Comment
Le bytes
Content read
-
-
-
-
1 byte
0x90
0x67
0x69
0x6A
0x6A
1 byte
0x00
0x00
0x82
0x82
0x86
-
Command completed
Wrong length
Security status not satisfied
File or application not found
Incorrect P1 or P2 values
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
The command configures the NDEF file to the ReadOnly or to the WriteOnly State.
This command can update the right access to the NDEF file by writing into the EEPROM. In this case, the response timing will be around 6 ms.
Table 45 defines the EnablePermanentState requirement command.
Name
Table 45. EnablePermanentState command format
CLA INS
-
Class byte
0xA2 0x28
Instruction code
New security attributes
0x0001: Lock the NDEF file in read mode
0x0002: Lock the NDEF file in write mode
Other: RFU
(empty field)
(empty field)
(empty field)
P1 and P2
2 bytes
Lc
-
Data
-
Le
-
Table 46 defines the R-APDU of the EnablePermanentState command.
Length
Value
Value
Value
Table 46. R-APDU table of the EnablePermanentState command
Data SW1 SW2 Comment
-
-
-
-
1 byte
0x90
0x65
0x69
1 byte
0x00
0x81
0x82
-
Command completed
Update failed
Security status not satisfied
46/66 DocID027817 Rev 5
ST25TA02K-D RF command sets
Value
Value
Table 46. R-APDU table of the EnablePermanentState command (continued)
Data SW1 SW2 Comment
-
0x6A
0x6A
0x82
0x86
File or application not found
Incorrect P1 or P2 values
Note:
For further return codes and definitions, refer to Section 5.6.2: Status and error codes
.
This command allows to modify the file type of a selected file to Proprietary file (0x05) or
NDEF file (0x04).
This command is granted only, when application and file are selected and if the file length and access right have previously been set to 0X00h (message invalid, all access rights granted).
This command will update the file type located in the CC file by writing into the EEPROM. In this case, the response timing will be around 6 ms.
Table 47 defines the UpdateFileType command.
Name CLA
Table 47. UpdateFileType command format
INS P1 P2 Lc Le
0xD6 0x00 0x00 0x01
Data
0x04 or
0x05
Value 0xA2
Class byte
Select instruction code
P1 field
P2 field
Number of bytes of data
-
File type
Table 48 describes the R-APDU of the UpdateFileType command.
Length
Value
Value
Value
Value
Value
Data
Table 48. R-APDU of the UpdateFileType command
SW1 SW2 Comment
-
-
-
-
-
-
1 byte
0x90
0x69
0x6A
0x6A
0x6A
1 byte -
0x00 Command completed
0x82 Security status not satisfied
0x80
0x82
0x86
CC file or System file selected
File or application not found
Incorrect P1 or P2 values
DocID027817 Rev 5 47/66
60
RF command sets ST25TA02K-D
On receiving the SendInterrupt command, the ST25TA02K-D generates a negative pulse on the GPO pin. It starts at the end of the command and ends at the end of the RF response.
Before sending this command, the system file shall be selected by issuing the System
Select command.
Table 49 defines the SendInterrupt command.
Length
Value
CLA
Table 49. SendInterrupt command format
INS P1 and P2 Lc Data
1 byte
0xA2
1 byte
0xD6
2 bytes
0x001E
1 byte
0x00 -
-
Le
-
-
Table 50 describes the R-APDU of the SendInterrupt command.
Length
Value
Value
Value
Value
Value
Data
Table 50. R-APDU of the SendInterrupt command
SW1 SW2 Comment
-
-
-
-
-
-
1 byte
0x90
0x6A
0x6A
0x6A
0x6E
1 byte -
0x00 The interrupt has been sent
0x80 The GPO is not configured as an interrupt mode
0x82
0x86
0x00
File or application not found
Incorrect P1 or P2 values
Class not supported
On receiving the StateControl command with reset value: data 0x00, the ST25TA02K-D drives the GPO pin low. On receiving the StateControl command with set value: data 0x01, the ST25TA02K-D releases the GPO pin that returns to HZ.
Before sending this command, the system file shall be selected by issuing the System
Select command.
Table 51 defines the State Control command.
Length
Reset value
Set value
CLA
1 byte
0xA2
0xA2
Table 51. StateControl command format
INS P1 and P2 Lc
1 byte
0xD6
0xD6
2 bytes
0x001F
0x001F
1 byte
0x01
0x01
Data
-
0x00
0x01
Le
-
-
-
48/66 DocID027817 Rev 5
ST25TA02K-D
Length
Value
Value
Value
Value
Value
RF command sets
Data
Table 52. R-APDU of the StateControl command
SW1 SW2 Comment
-
-
-
-
-
-
1 byte
0x90
0x6A
0x6A
0x6A
0x6E
1 byte -
0x00 The set or reset has been sent
0x80
0x82
The GPO is not configured in StateControl mode
File or application not found
0x86
0x00
Incorrect P1 or P2 values
Class not supported
5.9
5.9.1
Specific RF command set
This section describes the command set that can be issued only by the RF host.
Anticollision command set
Table 53 lists the commands that can be issued only by the RF host. The format of these
commands is described in the NFC Forum Digital Protocol specification.
Family command set
NFC-A technology
Table 53. Commands issued by the RF host
ALL_REQ
SENS_REQ
SDD_REQ
SEL_REQ
SLP_REQ
Command name Instruction code
0x52
(1)
0x26
(1)
0x93 or 0x95
0x93 or 0x95
0x50
1. Code on 7 bits.
Note:
Command
SENS_REQ or ALL-REQ
In response to a SDD_REQ Command with a SEL_PAR value equal to 20h, ST25TA02K-D in the Operating Field transmit the requested cascade level of their NFCID1 (NFCID1 CLn, with n = 1 or 2). The NFCID1 of ST25TA02K-D consists of 7 bytes. The length of the
Response containing a complete NFCID1 cascade level (i.e., NFCID1 CL1, or NFCID1 CL2) is always 5 bytes. The coding of the Response depends on the value of the SEL_CMD byte and the size of the NFCID1.
Refer to the example below for more details.
Table 54. Example of anticollision sequence
Comment Response Code Code
26
52
ATQA 42 00
Comment
UID double size bit frame anticollision
DocID027817 Rev 5 49/66
60
RF command sets ST25TA02K-D
Command
SDD_REQ 1
SEL_REQ 1
SDD_REQ 2
SEL_REQ 1
Table 54. Example of anticollision sequence (continued)
Code Comment Response Code Comment
93 20
93 70 CT uid1 uid2 uid3 BBC
95 20
NVB 20 Number Valid bit
(2 bytes Code and NVB)
-
CT uid1 uid2 uid3
BCC
CT Cascade Tag “0x88”
(UID 7bytes)
BCC Block Check
Character (XOR of previous Bytes)
NVB 70
(cmd NVB Uid lower bytes)
CT Cascade Tag “0x88”
SAK and CRC 04 DAD7 UID Not complete
NVB 20 Number Valid bit
(2 bytes Code and NVB)
uid4 uid5 uid6 uid7
BCC
(UID 7bytes) BCC Block
Check Character (XOR of previous Bytes)
95 70 uid4 uid5 uid6 uid7
BBC
NVB 70
(cmd NVB Uid upper bytes)
SAK and CRC 20 FC70 UID complete
50/66
RATS command and ATS response are used for NFC Forum Type 4A Tag Platform Device
Activation (as defined in NFC Forum Digital Protocol specification).
Table 55 details the RATS command. This command shall be sent after the anticollision
process.
Name
Byte field
Bit field
Instruction code
FSDI
DID (0 ≤ DID ≤ 14)
2 CRC bytes
INS
0xE0
Table 55. RATS command
Param
1 byte
b7-b4 b3-b0
CRC
2 bytes
-
The FSDI field codes the FSD, which defines the maximum size that an RF host is able to receive.
Table 56 gives the conversion from FSDI to FSD.
FSDI 0x0
FSD 16
0x1
24
Table 56. Conversion from FSDI to FSD
0x2 0x3 0x4 0x5 0x6 0x7 0x8
32 40 48 64 96 128 256
0x9h-
0xE
RFU
0xF
256
The DID (Dynamic ID, optionally affected to the ST25TA02K by the host to address
ST25TA02K-D in all commands) field defines the value of the addressed ST25TA02K-D.
DocID027817 Rev 5
ST25TA02K-D RF command sets
If DID is not ‘0’, the ST25TA02K-D ignores the command if it contains a DID different from the one affected to ST25TA02K-D during RATS.
Name TL T0
Table 57. ATS response
TA(1)
Byte field 0x05 0x75 0x80
Bit field -
Length of the ATS response
FSCI = 5 → FSC = 64 bytes
The maximum ascending data rate is 106 kbps
The maximum descending data rate is 106 kbps
FWI field (FWI = 6 → FWT = 19.2 ms)
SFGI field (SFGI = 0 → SFGT =302 µs)
The DID is supported
2 CRC bytes b8-b5
TB(1)
0x60 b4-b1
TC(1)
0x02
-
CRC
2 bytes
-
5.9.3
The FSCI codes the FSC, which stands for the maximum frame size that the ST25TA02K-D is able to receive. The ST25TA02K-D is able to receive up to 64 bytes of command. If the
RF host sends a command with more than 64 bytes, the ST25TA02K-D will not be able to treat the command and will not reply.
The FWI (Frame Waiting time Integer) codes the FWT, which stands for the Frame Waiting
Time. This time corresponds to the maximum duration while an RF host shall send before sending the next command.
The SFGI codes the SFGT, which stands for the Start-up Frame Guard Time. This is the minimum time that the reader shall wait after receiving the response of the ST25TA02K-D.
PPS command and response
(b)
PPS (Protocol and Parameter Selection) command and response are defined in ISO/IEC
14443-4, in the Protocol Activation of PICC Type A.
The PPS command allows to change the data rates of the ascending (RF host to
ST25TA02K-D) and descending (ST25TA02K-D to RF host) data rates. Usage of this command is optional, ST25TA02K-D only supports 106 Kb/s in both directions.
b. Not useful in case of ST25TA02K-D which only supports a Data Rate of 106 Kb/s in both directions.
DocID027817 Rev 5 51/66
60
RF command sets ST25TA02K-D
Name
Table 58. PPS command
INS (PPSS) PPS0
-
-
INS
PPS1
Byte field 0xDX 0x11
Bit field b7-b4 b3-b0
Instruction code
DID
PPS1 is present
RFU
Descending data rate (106 kb/s) = 0b00
Ascending data rate (106 kb/s) = 0b00
2 CRC bytes
0b0000
PPS1
1 byte b3-b2 b1-b0
CRC
2 bytes
-
The ascending and descending data rates shall be coded as described in
Value
Data rate
Table 59. Ascending and descending data rate coding
0b00 0b01 0b10
106 kbps RFU RFU
0b11
RFU
When the ST25TA02K-D is able to change both data rates, it returns the response detailed in
Table 60 . The data rate of this response is 106 kbps; then, the ST25TA02K-D changes
the ascending and descending data rates.
Name
Byte field
Bit field
Response code
DID field
2 CRC bytes
Table 60. PPS response
RESPONSE (PPSS)
0xDX b8-b5 b4-b1
CRC
2 bytes
-
52/66 DocID027817 Rev 5
ST25TA02K-D
6 RF device operation
6.1
RF device operation
Anticollision and Device Activation command set for the RF interface
The ST25TA02K-D device supports the command set defined in the NFC-A Technology and the Type 4A Tag Platform chapters of the NFC Digital Protocol V1.0 specification.
6.2 Open an RF session
Once the RF host has terminated the anticollision procedure and retrieve the ATS response, it shall send the SelectApplication command. The ST25TA02K-D will open an RF session.
At this point, the RF host can send the applicative command set.
6.3
6.4
Close an RF session
The RF host can close the RF session by issuing one of these methods:
• send an S(DES) command
• turn off the RF field
Applicative command set
The applicative command set is composed of the following command sets:
• the NFC Forum Type 4 Tag command set
• the ISO/IEC 7816-4 command set
• the proprietary command set
DocID027817 Rev 5 53/66
60
Functional procedures ST25TA02K-D
7.1
7.2
7.3
7.4
This section describes some procedure to access the memory or manage its protection.
Selection of an NDEF message
The RF host shall use this procedure to detect the NDEF message inside an ST25TA02K-D.
The NDEF detection procedure is as follows:
1.
Open an RF session
2. Send the SelectNDEFTagApplication command
3. Select the CC file
4. Read the CC file
5. Select the NDEF file.
Reading of an NDEF message
The RF host executes the NDEF read procedure to read the NDEF file.
1.
Detect successfully the NDEF file using the NDEF detection procedure
2. Check that the read access without any security is granted for the NDEF file from the information provided by the CC file
3. Select the NDEF file
4. Read the NDEF file.
Reading a locked NDEF file
The RF host executes this procedure to read an NDEF file which has been locked previously.
1.
Select the NDEF Tag Application
2. Select the NDEF file
3. Present the Read password by using the Verify command
4. Read the data in the NDEF file.
Locking an NDEF file
The RF host executes this procedure to protect an NDEF file.
1.
Select the NDEF Tag Application
2. Check the right access provided by the CC file
3. Select the NDEF file
4. Present the NDEF file Write password by using the Verify command
5. Lock the NDEF file by sending the Enable verification command.
54/66 DocID027817 Rev 5
ST25TA02K-D
7.5
Functional procedures
Unlocking an NDEF file
The RF host executes this procedure to unlock an NDEF file which has been locked previously.
1.
Select the NDEF Tag Application
2. Select the NDEF file
3. Present the NDEF file Write password by using the Verify command
4. Unlock the NDEF file by sending the Disable verification command.
7.6 Reaching the read-only state for an NDEF file
The RF host executes this procedure to permanently lock an NDEF file that has been previously locked with password.
1.
Select the NDEF Tag Application
2. Select the NDEF file
3. Transmit the NDEF file Write password by using the Verify command
4. Send an EnablePermanentState command
7.7 Creating or Updating an NDEF file
1.
Select the NDEF Tag Application
2. Select the NDEF file
3. Set the File Length to 0x00 using the UpdateBinary command
4. Write NDEF message content using the UpdateBinary command
5. Set the new File Length (must be always two written bytes)
0x0001)
The RF host executes this procedure to change the File Type of a file for which all access rights were previously granted.
1.
Select the NDEF Tag Application
2. Select the file 0x0001
3. Set the File Length to 0x00 using the UpdateBinary command
4. Send an UpdateFileType command with the New file Type as data
DocID027817 Rev 5 55/66
60
UID: Unique identifier ST25TA02K-D
The ST25TA02K-D is uniquely identified by a 7 bytes unique identifier (UID). The UID is a read-only code and comprises:
• The IC manufacturer code on 1 byte (0x02 for STMicroelectronics).
• The Product code on 1 byte.
• A device number on 5 bytes.
Table 61 describes the UID format.
Table 61. UID format
0x02 0xF2 5 bytes -
IC manufacturer code
ST25TA02K-D product code
Device number
56/66 DocID027817 Rev 5
ST25TA02K-D Maximum ratings
Stressing the device above the ratings listed in
may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the operating sections of this specification is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect the device reliability.
Symbol
Table 62. Absolute maximum ratings
Parameter Min.
Max.
Unit
T
T
A
STG h
STG t
STG
,
,
Ambient operating temperature
Storage conditions
Sawn wafer on UV tape
-40
15
-
85
25
9
(1)
°C
°C months
Kept in its original packing form
V
V
I
T
T
T
V
STG
STG
LEAD
DCG
CC
(4)
MAX_1
(4)
MAX_2
(4)
V
V
ESD
ESD
Storage temperature
Storage temperature Sawn bumped
Storage time wafer
(kept in its antistatic bag)
Lead temperature during soldering
UFDFPN8 or
UFDFPN5
GPO Power Supply
UFDFPN8 or
UFDFPN5
RF supply current AC0 - AC1
RF input voltage amplitude between
AC0 and AC1, V
SS left floating
pad
VAC0-VAC1
(Peak to Peak)
AC voltage between
AC0 and V
SS and V
SS
, or AC1
Electrostatic discharge voltage (human body model) (5)
VAC0-V
SS
or
VAC1-V
SS
AC0-AC1
Electrostatic discharge voltage (human body model)
(5)
Other pads
–65
15
-
-0.5
-0.5
-
-
-
-
See note
(3)
150
25
9 (2)
5.5
64
10
4.5
2000
3500
V mA
1. Counted from ST shipment date.
2. Counted from ST production (taping) date.
3. Compliant with JEDEC Std J-STD-020D (for small body, Sn-Pb or Pb assembly), the ST ECOPACK directive 2011/65/EU, July 2011).
®
7191395 specification, and the European directive on Restrictions on Hazardous Substances (ROHS
4. Based on characterization, not tested in production. Maximum absorbed power = 100 mW @ 7.5 A/m
5. AEC-Q100-002 (compliant with JEDEC Std JESD22-A114A, C1 = 100 pF, R1 = 1500 Ω , R2 = 500 Ω )
°C
°C months
°C
V
V
V
V
DocID027817 Rev 5 57/66
60
GPO characteristics ST25TA02K-D
This section summarizes the operating and measurement conditions of the GPO feature.
The DC and AC characteristics are derived from tests performed under the measurement conditions summarized in the following tables. GPO I/O is CMOS compliant.
Symbol
V
DCG
Table 63. GPO operating conditions
Parameter Min.
GPO Power Supply 1.65
Max.
5.5
Unit
V
Symbol
V
OL
(1)
Parameter
Table 64. DC characteristics
Test condition
Output Low voltage (GPO)
I
OL
= 1 mA,
Pull-up supply = 1.65 to 5.5 V
1. Characterized only
Min.
-
Max.
Unit
0.4 V V
58/66 DocID027817 Rev 5
ST25TA02K-D GPO parameters
This section lists the timing of the GPO according to its configuration.
GPO field I/F
Table 65. GPO timings measurement (1)
Condition Command Symbol Typ.
Unit
Session Open
WIP
0x10 or
0x90
0x20 or
0xA0
RF
RF
RF
RF
GPO when session active
GPO return
GPO when programming
NDEF select
Deselect
Update Binary
CmdEOFtoGP
CmdEOFtoGP
CmdEOFtoGPlow
Writing time duration
(No time extension)
170
370
75
(2)
µs
µs
µs ms
Message In
Progress
Interrupt
State Control
0x30 or
0xB0
0x40 or
0xC0
0x50 or
0xD0
RF
RF
RF
RF
RF
RF
GPO when modifying NDEF
GPO when modifying NDEF
GPO after receiving an
Interrupt command
GPO when reset
GPO return when set
UpdateBinary (Msg
Length #0)
UpdateBinary
SendInterrupt
Reset GPO
Set GPO
CmdEOFtoGP
Writing time duration
(No time extension)
CmdEOFtoGP
Pulse duration
CmdEOFtoGP
CmdEOFtoGP
75
(2)
75
540
60
60
µs ms
µs
µs
µs
µs
RF Busy
0x60 or
0xE0
RF
RF
GPO after receiving an RF command
GPO return after deselection or RF command in another protocol
Anticollision command or start of
RF disturb
(command using another RF protocol)
Deselect or end of
RF disturb
(command using another RF protocol)
CmdSOFtoGP
CmdEOFtoGP
6
460
µs
µs
Field detect
0x70 or
0xF0
RF
GPO when RF field is present
t
FDETON t
FDETOFF
140
20
µs
µs
1. Characterized only.
2. Writing time is function of the message length and is automatically manage by ST25TA02K-D. NDEF message is mapped on memory blocks of 16 bytes. Each basic block has a typical update time duration of 6 ms including the internal verify.
DocID027817 Rev 5 59/66
60
RF electrical parameters
12 RF electrical parameters
ST25TA02K-D
This section summarizes the operating and measurement conditions, and the DC and AC characteristics of the device in RF mode.
The parameters in the DC and AC characteristics tables that follow are derived from tests performed under the measurement conditions summarized in the relevant tables. Designers should check that the operating conditions in their circuit match the measurement conditions when relying on the quoted parameters.
Symbol
T
A
Table 66. Default operating conditions
Parameter Min.
Ambient operating temperature –40
Max.
85
Unit
°C
Symbol Parameter
Table 67. RF characteristics
(1)
Condition Min Typ Max Unit f
C
H_ISO
H_Extended
H min
MI
CARRIER t
1 t
2 t
3 t
4
External RF signal frequency
Operating field according to ISO
Operating field in extended temperature range
Field detect, Set-up field (1)
100% carrier modulation index
Pause A length
Pause A low time
Pause A rise time
T
T
T
A
A
A
-
= 0 °C to 50 °C
= -40 °C to 85 °C
= -40 °C to 85 °C
MI=(A-B)/(A+B)
-
-
-
13.553
1500
100
-
90
28 / f
C
7 / f
C
1.5 x t
4
0
13.56
-
-
115
-
-
-
t
MIN CD
Pause A rise time section
Minimum time from carrier generation to first data
-
From H-field min -
-
W t
C
TUN
(3) t
RF_OFF
RF write time (including internal
Verify) for one page
Internal tuning capacitor
RF OFF time
(4) f
C
-
= 13.56 MHz
Chip reset
-
45
-
4.468
50
-
(2)
1. All timing characterizations were performed on a reference antenna with the following characteristics:
External size: 75 mm x 48 mm
Number of turns: 4
Width of conductor: 0.5 mm
Space between two conductors: 0.5 mm
Value of the tuning capacitor: 50 pF (ST25TA02K-D)
Value of the coil: 2.5 µH
Tuning frequency: 14.2 MHz.
2. Time between command EOF and Response SOF when Updating NDEF Message Length
3. See
4. Characterized only, at room temperature only, measured at VAC0-VAC1 = 5 V peak to peak at 13.56 MHz.
13.567
7500
7500
-
100
40.5 / f t
1
16 / f
C
6 / f
5
-
55
0.1
C
C
MHz mA/m mA/m mA/m
%
µs
µs
µs
µs ms ms pF ms
60/66 DocID027817 Rev 5
ST25TA02K-D Package information
In order to meet environmental requirements, ST offers these devices in different grades of
ECOPACK ® packages, depending on their level of environmental compliance. ECOPACK ® specifications, grade definitions and product status are available at www.st.com
.
ECOPACK ® is an ST trademark.
13.1 UFDFPN8 package information
Figure 14. UFDFPN8 - 8-lead, 2 × 3 mm, 0.5 mm pitch ultra thin profile fine pitch dual flat package outline
1
' $ %
3LQ
,'PDUNLQJ
(
$
$
FFF
HHH &
6HDWLQJSODQH
6LGHYLHZ
$
&
[ DDD &
[ DDD &
7RSYLHZ
'
H E
'DWXP$
/
/
/ /
3LQ
,'PDUNLQJ
/
(
.
H
H
'HWDLO³$´
(YHQWHUPLQDO
/
7HUPLQDOWLS
1'[ H
%RWWRPYLHZ
6HH'HWDLO³$´
=:DB0(B9
1. Max. package warpage is 0.05 mm.
2. Exposed copper is not systematic and can appear partially or totally according to the cross section.
3. Drawing is not to scale.
4. The central pad (the area E2 by D2 in the above illustration) must be either connected to VSS or left floating (not connected) in the end application.
DocID027817 Rev 5 61/66
64
Package information ST25TA02K-D
Table 68. UFDFPN8 - 8-lead, 2 × 3 mm, 0.5 mm pitch ultra thin profile fine pitch dual flat package mechanical data millimeters inches
(1)
Symbol
Min Typ Max Min Typ Max e
K
L
L1
L3 aaa bbb ccc ddd eee
(3)
D
D2
E
E2
A
A1 b
(2)
0.450
0.000
0.200
1.900
1.500
2.900
0.100
-
0.800
0.400
-
0.300
-
-
-
-
-
0.550
0.020
0.250
2.000
1.600
3.000
0.200
0.500
-
0.450
-
-
-
-
-
-
-
0.600
0.050
0.300
2.100
1.700
3.100
0.300
-
-
0.500
0.150
-
0.150
0.100
0.100
0.050
0.080
0.0177
0.0000
0.0079
0.0748
0.0591
0.1142
0.0039
0.0315
0.0157
-
0.0118
-
-
-
-
-
0.0217
0.0008
0.0098
0.0787
0.0630
0.1181
0.0079
0.0197
-
-
-
-
0.0177
-
-
-
-
0.0236
0.0020
0.0118
0.0827
0.0669
0.1220
0.0118
-
0.0197
0.0059
-
0.0059
0.0039
0.0039
0.0020
0.0031
1. Values in inches are converted from mm and rounded to 4 decimal digits.
2. Dimension b applies to plated terminal and is measured between 0.15 and 0.30 mm from the terminal tip.
3. Applied for exposed die paddle and terminals. Exclude embedding part of exposed die paddle from measuring.
62/66 DocID027817 Rev 5
ST25TA02K-D Package information
13.2 UFDFPN5 package information
Figure 15. UFDFPN5 - 5-lead, 1.7 × 1.4 mm, 0.55 mm thickness package outline
'
N /
3LQ 3LQ
(
E
(
H
$
7RSYLHZ
PDUNLQJVLGH
$
6LGHYLHZ
'
%RWWRPYLHZ
SDGVVLGH
$8.B0(B9
1. Max. package warpage is 0.05 mm.
2. Exposed copper is not systematic and can appear partially or totally according to the cross section.
3. Drawing is not to scale.
Table 69. UFDFPN5 - 5-lead, 1.7 × 1.4 mm, 0.55 mm thickness package mechanical data millimeters inches
(1)
Symbol
Min Typ Max Min Typ Max
D
D1
E
E1
A
A1 b
(2) e
L
L1 k
0.500
0.000
0.175
1.600
1.400
1.300
0.175
-
0.500
-
-
0.550
-
0.200
1.700
1.500
1.400
0.200
0.400
0.550
0.100
0.400
0.600
0.050
0.225
1.800
1.600
1.500
0.225
-
0.600
-
-
0.0197
0.0000
0.0069
0.0630
0.0551
0.0512
0.0069
-
0.0197
-
-
0.0217
-
0.0079
0.0669
0.0591
0.0551
0.0079
0.0157
0.0217
0.0039
0.0157
1. Values in inches are converted from mm and rounded to 4 decimal digits.
2. Dimension b applies to plated terminal and is measured between 0.15 and 0.30mm from the terminal tip.
0.0236
0.0020
0.0089
0.0709
0.0630
0.0591
0.0089
-
0.0236
-
-
DocID027817 Rev 5 63/66
64
Ordering information ST25TA02K-D
Table 70. Ordering information scheme for packaged devices
ST25 T A 02K D - C 6 G/H/C 5
Device type
ST25 = RF memory
Product Type
T = Tags + RFID
Protocol
A = ISO14443-A
Memory density
02K (binary)
Customization type
None = Standard product
K = Customized product
Interface
D = OD GPO
Features
C = Counter as option
Operating temperature
6 = -40 o C to +85 o C
Package / Packing
G = Sawn and bumped wafer, 120 ± 15 µm
H = DFN5
C = DFN8
Capacitor value
5 = 50 pF
Note: Parts marked as “ES”, “E” or accompanied by an Engineering Sample notification letter, are not yet qualified and therefore not approved for use in production. ST is not responsible for any consequences resulting from such use. In no event will ST be liable for the customer using any of these engineering samples in production. ST’s Quality department must be contacted prior to any decision to use these engineering samples to run a qualification activity.
64/66 DocID027817 Rev 5
ST25TA02K-D Revision history
Date
03-Aug-2015
12-Feb-2016
02-Sep-2016
21-Feb-2017
05-Oct-2017
Revision
Table 71. Document revision history
Changes
1
2
3
4
5
Initial release.
Updated Section 2.2: Ground (VSS) ,
Section 2.3.3: MIP NDEF Message writing in Progress configuration (GPO field = 0x30 or 0xB0)
,
Section 2.3.4: INT Interrupt configuration (GPO field = 0x40 or 0xC0) ,
Section 2.3.5: State Control configuration (GPO field = 0x50 or 0xD0)
,
Section 2.3.6: RF busy configuration (GPO field = 0x60 or 0xE0) ,
Section 5.9.2: RATS command and ATS response ,
Unlocking an NDEF file , Section 7.6: Reaching the read-only state for an
and
Section 7.8: Changing a File Type Procedure (applicable only on file 0x0001)
.
Added Section 5.8.3: UpdateFileType command
,
,
Section 5.8.5: StateControl command and
Section 7.7: Creating or Updating an NDEF file .
Updated Figure 5: GPO configured as Session Open (GPO field = 0x10 or 0x90) and its footnote 2 .
Updated footnote
of
Figure 9: GPO configured as State Control (GPO field = 0x50 or 0xD0)
.
Updated Figure 10: GPO configured as RF busy (GPO field = 0x60 or
Updated Figure 11: Field detect (GPO field = 0x70 or 0xF0)
and
Figure 12: Changing the read access right to an NDEF file .
Added footnote
to
Updated Table 62: Absolute maximum ratings and
Table 70: Ordering information scheme for packaged devices .
and image on cover page.
Updated footnotes of figures
and
Updated Section 5.9.2: RATS command and ATS response ,
Section 5.9.3: PPS command and response and
Section 10: GPO characteristics .
Updated Table 11: RF command sets
,
Table 62: Absolute maximum ratings and
Table 70: Ordering information scheme for packaged devices
.
Updated title of
Section 14: Ordering information and of
.
Updated Table 67: RF characteristics and its footnote 4 .
Updated Section 13.1: UFDFPN8 package information .
.
.
Updated footnote
of
DocID027817 Rev 5 65/66
65
ST25TA02K-D
IMPORTANT NOTICE – PLEASE READ CAREFULLY
STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on
ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at the time of order acknowledgement.
Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or the design of Purchasers’ products.
No license, express or implied, to any intellectual property right is granted by ST herein.
Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product.
ST and the ST logo are trademarks of ST. All other product or service names are the property of their respective owners.
Information in this document supersedes and replaces information previously supplied in any prior versions of this document.
© 2017 STMicroelectronics – All rights reserved
66/66 DocID027817 Rev 5