ST25TA16K
NFC Forum Type 4 Tag IC with 16-Kbit EEPROM
Datasheet
-
production data
Description
The ST25TA16K device is an NFC tag IC embedding an EEPROM memory. It can be operated from a 13.56 MHz RFID reader or an
NFC phone.
The RF protocol is compatible with ISO/IEC
14443 Type A and NFC Forum Type 4 Tag.
Wafer (SB12I)
Features
Contactless interface
• NFC Forum Type 4 Tag
• ISO/IEC 14443 Type A
• 106 Kbps data rate
• Internal tuning capacitance: 25 pF
Memory
• 2-Kbyte (16-kbit) EEPROM
• Supports NDEF data structure
• Data retention: 200 years
• Endurance: 1 million erase-write cycles
• Reads up to 246 bytes in a single command
• Writes up to 246 bytes in a single command
• 7-byte unique identifier (UID)
• 128-bit password protection
February 2017
This is information on a product in full production.
DocID027786 Rev 4
www.st.com
1
Contents
Contents
ST25TA16K
Antenna coil (AC0, AC1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ST25TA16K memory management . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Read and write access rights to the memory . . . . . . . . . . . . . . . . . . . . . . 13
State of the Read and Write access rights . . . . . . . . . . . . . . . . . . . . . . . 13
Changing the read access right to NDEF files . . . . . . . . . . . . . . . . . . . . 14
Changing the write access right to NDEF files . . . . . . . . . . . . . . . . . . . 15
Communication mechanism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Structure of the command sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
C-APDU: payload format of a command . . . . . . . . . . . . . . . . . . . . . . . . 19
R-APDU: payload format of a response . . . . . . . . . . . . . . . . . . . . . . . . 20
NFC Forum Type 4 Tag protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
DocID027786 Rev 4
ST25TA16K
Contents
NDEF Tag Application Select command . . . . . . . . . . . . . . . . . . . . . . . . 23
Capability Container Select command . . . . . . . . . . . . . . . . . . . . . . . . . . 24
NDEF Select command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
System File Select command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
ReadBinary command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
UpdateBinary command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
ISO/IEC 7816-4 commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Change Reference Data command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Enable Verification Requirement command . . . . . . . . . . . . . . . . . . . . . . 30
Disable Verification Requirement command . . . . . . . . . . . . . . . . . . . . . 31
ST proprietary command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
ExtendedReadBinary command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
EnablePermanentState command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
UpdateFileType command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Specific RF command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Anticollision command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
RATS command and ATS response . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
PPS command and response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Anticollision and Device Activation command set for the RF interface . . 39
Applicative command set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Functional procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Selection of an NDEF message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Reading of an NDEF message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Reading a locked NDEF file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Reaching the read-only state for an NDEF file . . . . . . . . . . . . . . . . . . . . . 41
Creating or updating an NDEF file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
DocID027786 Rev 4
4
Contents ST25TA16K
Changing the file type (applicable only on file 0x0001) . . . . . . . . . . . . . . 41
DocID027786 Rev 4
ST25TA16K
List of tables
List of tables
DocID027786 Rev 4
6
List of tables ST25TA16K
DocID027786 Rev 4
ST25TA16K
List of figures
List of figures
DocID027786 Rev 4
7
Functional description ST25TA16K
The ST25TA16K device is a dynamic NFC/RFID tag that can be accessed from the RF interface. The RF interface is based on the ISO/IEC 14443 Type A standard.
The ST25TA16K is compatible with the NFC Forum Type 4 Tag specifications and supports all corresponding commands.
Figure 1 shows the block diagram of the ST25TA16K device.
Figure 1. ST25TA16K block diagram
3RZHU
PDQDJHPHQW
XQLW h/ΘƐLJƐƚĞŵ
ĂƌĞĂ
5)LQWHUIDFH
EDVHGRQ
,62,(&
7\SH$
VWDQGDUG
$&
$&
$QDORJ)URQWHQG
EDVHGRQ
,62,(&
7\SH$VWDQGDUG
,QWHUQDOWXQLQJ
FDSDFLWDQFH
1)&)RUXP
7\SH7DJ
SURWRFRO
1RW
FRQQHFWHG
'LJLWDOXQLW hƐĞƌŵĞŵŽƌLJ
9
66
Signal name
AC0, AC1
Table 1. Signal names
Function
Antenna coils
Direction
-
069
DocID027786 Rev 4
ST25TA16K Functional description
The ST25TA16K has just one functional mode (see Table 2 ).
Mode
Tag mode
Table 2. Functional mode
Supply source
RF field only
Comments
The interface is connected
The ST25TA16K is supplied by the RF field and can communicate with an RF host (RFID reader or an NFC phone). The User memory can only be accessed by the RF commands.
DocID027786 Rev 4
10
Signal descriptions ST25TA16K
2.1 Antenna coil (AC0, AC1)
These inputs are used to connect the device to an external coil exclusively. It is advised not to connect any other DC or AC path to AC0 or AC1.
When correctly tuned, the coil is used to access the device using NFC Forum Type 4 commands.
DocID027786 Rev 4
ST25TA16K
3
ST25TA16K memory management
ST25TA16K memory management
The ST25TA16K supports the NDEF Tag Application as defined in the NFC Forum Type 4
Tag. The ST25TA16K is composed of three files:
• one Capability Container file;
• one NDEF file;
• one System file: this is an ST-proprietary file.
The System file contains some information on the configuration of the ST25TA16K device.
The CC file gives some information about the ST25TA16K itself and the NDEF file. The
NDEF file contains the User data.
The file identifier is the value used in the Select command to select a file.
File identifier
0xE101
0xE103
0x0001
System file
CC file
NDEF file
Table 3. File identifier
Meaning
The CC file gives some information about the ST25TA16K and the NDEF file. This file is a read-only file for the RF host and cannot be modified by issuing a write command.
The T, Read Access and Write Access fields can be changed by the RF host through a
specific process (refer to Section 7: Functional procedures ).
File offset
0x0000
0x0002
0x0003
0x0005
Table 4. CC file layout for one NDEF file
Meaning
Number of bytes of CC file
Mapping version
(1)
Maximum number of bytes that can be read
Maximum number of bytes that can be written
Value Comments
0x000F 15 bytes
0x20 or 0x10 V 2.0 or V 1.0
0x00F6 246 bytes
0x00F6 246 bytes
DocID027786 Rev 4
15
ST25TA16K memory management ST25TA16K
File offset
0x0007
0x0008
0x0009
0x000B
Table 4. CC file layout for one NDEF file (continued)
Meaning Value
0x04
(2)
0x06
0x0001
NDEF file control TLV
0x0800
0x000D
0x000E
1. According to the reader.
2. Delivery state.
0x00
(2)
0x00
(2)
Comments
T field
L field
FileID
Maximum NDEF file size
Read access
Write access
The NDEF file contains the NDEF message that contains the User data. The RF host can read and write data inside the file. The first two bytes named NDEF Message Length define the size of the NDEF message. The NDEF Message Length shall be managed by the application and the ST25TA16K device does not check if its value is relevant vs the data written by the RF host. The ST25TA16K device uses the NDEF Message Length, e. g. the standard read can be processed only inside the NDEF message; otherwise, the
ST25TA16K device returns an error code. For more details about the read command, refer to
Section 5.6.7: ReadBinary command .
File offset
0x0000
0x0004
...
...
...
0x07FC
Table 5. NDEF file layout
Byte 0 Byte 1
NDEF message length
User data
...
...
...
...
User data
...
...
...
...
Byte 2
User data
User data
...
...
...
...
Byte 3
User data
User data
...
...
...
User data
The system file specifies the configuration of the ST25TA16K. Table 6 lists the different
fields.
File offset
0x0000
0x0002
0x0003
Field name
Length system file
ST reserved
ST reserved
Table 6. Field list
Number of bytes
Read access
2
1
1
RF
RF
RF
Write access
none none
Delivery state
0x0012
0x01
0x00
DocID027786 Rev 4
ST25TA16K ST25TA16K memory management
File offset Field name
Table 6. Field list (continued)
Number of bytes
Read access
Write access
0x0004
0x0005
0x0006
0x0007
0x0008
0x000F
0x0011
ST reserved
ST reserved
ST reserved
NDEF File number
(RFU)
UID
Memory Size
Product Code
1
1
1
1
7
2
1
1. x values are defined by ST to insure UID unicity.
RF
RF
RF
RF
RF
RF
RF none none none none none none none
Delivery state
0x11
0x00
0x01
0x00
0x02C5 xx xx xx xx xx
(1)
0x07FF
0xC5
3.2
3.2.1
Read and write access rights to the memory
An NDEF file can be locked for read or write accesses. It is also protected by a 128-bit password that the host shall present before accessing the NDEF file. There are two 128-bit passwords, one for the read access and the other one for the write access.
An NDEF file can be permanently locked for read or write accesses. Thus, the host cannot access the NDEF file.
The read password shall be sent to the ST25TA16K device before reading a read-locked
NDEF file.
The write password shall be present on the ST25TA16K device before writing a write-locked
NDEF file. The write password shall be sent to change the read or write access. The read or write access right is defined for the NDEF file.
State of the Read and Write access rights
Two bytes in the CC file are used to define the Read and Write access rights to the NDEF file. For more details, refer to
Section 3.1.2: CC file layout .
Value
Table 7. Read access right
Meaning
0x00
0x80
0xFE
Read access without any security
Locked (1)
Read not authorized
1. The read password shall be sent before reading in the NDEF file.
DocID027786 Rev 4
15
ST25TA16K memory management ST25TA16K
Value
Table 8. Write access right
Meaning
0x00
0x80
0xFF
Write access without any security
Locked
(1)
Write not authorized
1. The write password shall be sent before writing in the NDEF file.
The state 0xFF and 0xFE cannot be changed by using the Read or Write passwords.
shows how to change the access right to read an NDEF file.
Figure 2. Changing the read access right to an NDEF file
[
/RFNWKH1'()ILOH
8QORFNWKH1'()ILOH
[ [)(
3HUPDQHQWO\ORFNWKH1'()ILOH
069
1. See the procedure to lock the read access ( Section 7.4: Locking an NDEF file ).
2. See the procedure to unlock the read access (
Section 7.5: Unlocking an NDEF file
).
3. See the procedure to permanently lock the read access (
Section 7.6: Reaching the read-only state for an
4. Proprietary state, not defined by NFC Forum Type 4 Tag.
DocID027786 Rev 4
ST25TA16K ST25TA16K memory management
The state diagram on
Figure 3 shows how to change the write access right to an NDEF file.
Figure 3. Changing the write access right to an NDEF file
[
/RFNWKH1'()ILOH
8QORFNWKH1'()ILOH
3.3
[
3HUPDQHQWO\ORFNWKH1'()ILOH
[))
069
1. See the procedure to lock the write access.
2. See the procedure to unlock the write access.
3. See the procedure to permanently lock the write access (
Section 7.6: Reaching the read-only state for an
4. Proprietary state, not defined by NFC Forum Type 4 Tag.
Access right life time
The access right life time is validated while the NDEF file is selected or until the end of the
RF session. Once the read or write access right is granted, the host can send one or more
ReadBinary or UpdateBinary commands.
At the end of a session or when the host selects another file, the read and write access rights are initialized.
Note:
The NDEF file passwords protect the read or write access from an RF interface from/to an
NDEF file.
Two NDEF file passwords are available for each NDEF file:
• Read password
• Write password
The length of a password is 128 bits (16 bytes).
The delivery state for all passwords is 0x00000000000000000000000000000000.
DocID027786 Rev 4
15
Communication mechanism ST25TA16K
4.1
This chapter describes the principle of communication between an RF host and the
ST25TA16K device.
Master and slave
The ST25TA16K acts as a slave device on the RF channel and therefore waits for a command from the RF host before sending its response.
The RF host shall generate the RF field and the RF commands.
DocID027786 Rev 4
ST25TA16K
5 RF command sets
RF command sets
This section describes the ST25TA16K command sets that can be issued by the RF host.
There are three command families:
• the NFC Forum Type 4 Tag command set
• the ISO/IEC 7816-4 command set
• the proprietary command set
The NFC Forum Type 4 Tag command set and the ISO/IEC 7816-4 command set use the I-
Block format. For more details about the I-Block format, refer to Section 5.2: I-Block format .
Two other command formats exist:
• the commands using the R-Block format
• the commands using the S-Block format
For more details about these formats, refer to the corresponding sections:
and
.
This section gives a brief description of the RF host commands. The format of these command sets is the I-Block format.
Table 9 lists the RF command sets.
Family command set
Table 9. RF command sets
Command name
Class byte
Instruction code
Brief description
NFC Forum
Type 4 Tag
NDEF Tag Application Select
CC select
NDEF select
System select
ReadBinary
UpdateBinary
Verify
ISO/IEC 7816-4
ChangeReferenceData
EnableVerificationRequirement
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
DisableVerificationRequirement 0x00
0xA4
0xA4
0xA4
0xA4
0xB0
0xD6
0x20
0x24
0x28
0x26
NDEF Tag Application
Select
Selects the CC file
Selects the NDEF file
Selects the system file
Reads data from file
Writes or erases data to a
NDEF file
Checks the right access of a NDEF file or sends a password
Changes a Read or write password
Activates the password security
Disables the password security
DocID027786 Rev 4
44
RF command sets ST25TA16K
Family command set
Table 9. RF command sets (continued)
Command name
Class byte
Instruction code
EnablePermanentState
ST proprietary ExtendedReadBinary
UpdateFileType
0xA2
0xA2
0xA2
0x28
0xB0
0xD6
Brief description
Enables the Read Only or
Write Only security state
Reads data from file
Sets file type to NDEF or proprietary
5.1 Structure of the command sets
The exchange of data between the RF host and the ST25TA16K uses three kinds of data formats, called blocks:
• I-Block: to exchange the command and the response
• R-Block: to exchange positive or negative acknowledgment
• S-Block: to use either the Deselect command or the Frame Waiting eXtension (WTX) command or response
This section describes the structure of the I-Block, R-block and S-Block. This format is used for the application command set.
The I-Block is used to exchange data between the RF host and the ST25TA16K. It is composed of three fields.
Table 10 details the I-Block format.
Name
PCB
Length 1 byte
PCB field
DID field (optional)
RF host to ST25TA16K: C-APDU
ST25TA16K to RF host: R-APDU
2 CRC bytes
Table 10. I-Block format
SoD Payload
DID -
1 byte 1 to 251 bytes
EoD
CRC
2 bytes
DocID027786 Rev 4
ST25TA16K
5.2.1
RF command sets b7-b6
0b00
I-Block
RFU
Must be set to 0
DID field, if bit is set
Must be set to 0
Must be set to 1
Block number
Table 11. PCB field of the I-Block format b5 b4 b3 b2
0 0 X 0 b1
1 b0
X
When the RF host sends a command to the ST25TA16K the format of the payload is the
C-APDU.
When the ST25TA16K sends a command to the RF host, the format of the payload is the
R-APDU.
C-APDU: payload format of a command
The C-APDU format is used by the RF host to send a command to the ST25TA16K.
Table 12 describes its format.
Name
INS
Table 12. C-APDU format
Payload field
P1 P2 CLA
Length 1 byte 1 byte 1 byte
Class byte
0x00: standard command
0xA2: ST command
Instruction byte
Param Byte 1
Param Byte 2
Number of bytes of the Data field
Data bytes
Number of bytes to be read in the ST25TA16K memory
1 byte
LC
1 byte
Data Le
Lc byte 1 byte
DocID027786 Rev 4
44
RF command sets ST25TA16K
The ST25TA16K uses the I-Block format to reply to a command that used the I-Block format. This format is described in
Name
Table 13. R-APDU format
Payload field
Data (optional) SW1
Le byte 1 byte Length
Data
Status byte 1
Status byte 2
SW2
1 byte
The R-Block is used to convey positive or negative acknowledgment between the RF host and the ST25TA16K.
Table 14. R-Block format
PCB
R(ACK) without the DID field: 0xA2 or 0xA3
R(ACK) with the DID field: 0xAA or 0xAB
R(NAK) without the DID field: 0xB2 0xB3
R(NAK) with the DID field: 0xBA 0xBB
CRC
2 CRC bytes
There are two kinds of R-Blocks:
• R(ACK): the acknowledgment block sent by the RF host or by the ST25TA16K
• R(NAK): the non-acknowledgment block sent by the RF host or by the ST25TA16K b7-b6
0b10
R-Block
RFU
0: NAK
1: ACK
0: DID field is not present
1: DID field is present
Must be set to 0
RFU
Block number
Table 15. R-Block detailed format b5 b4 b3
1 X X b2
0 b1
0 b0
X
DocID027786 Rev 4
ST25TA16K RF command sets
The S-Block is used to exchange control information between a reader and a contactless tag.
NFC frame
PCB
Table 16. S-Block format
SoD
DID
Payload
-
EoD
CRC
Length 1 byte 1 byte 0 to 1 byte
0xC2: for S(DES) when the DID field is not present
0xCA: for S(DES) when the DID field is present
0xF2: for S(WTX) when the DID field is not present
0xFA: for S(WTX) when the DID field is present
DID field (optional)
WTX field
(1)
2 CRC bytes
1. This field is present when b5-b4 bits are set to 0b11 (S-Block is a WTX). see
Table 17: S-Block detailed format .
2 bytes
There are two requests using the S-Block format:
• S(DES): the deselect command
• S(WTX): the Waiting Frame eXtension command or response.
Table 17. S-Block detailed format b5-b4 b3 b2
X X 0 b7-b6
0b11
S-Block
0b00: Deselect
0b11: WTX
-
0: DID field is not present
1: DID field is present
RFU
RFU b1
1 b0
0
Note: After receiving the deselect command, the session is released and ST25TA16K enters the
Standby power mode.
In response to a RATS command, ST25TA16K returns FWI parameter (default frame waiting time used); when ST25TA16K needs more time for a command execution, it requests a frame waiting time extension by responding 0xF2 0xWTX (Request waiting time = FWI *
WTX). If the reader accepts ST25TA16K request, it acknowledges by sending the command
0xF2 0xWTX. The frame waiting time becomes FWI * WTX for the current command only.
DocID027786 Rev 4
44
RF command sets
5.5 CRC of the RF frame
ST25TA16K
The two CRC bytes check the data transmission between the RF host and the ST25TA16K.
For the RF frame, the CRC is computed on all the data bits in the frame, excluding parity bits, SOF and EOF, and the CRC itself.
The CRC is as defined in ISO/IEC 13239. The initial register content shall be 0x6363 and the register content shall not be inverted after calculation.
5.6 NFC Forum Type 4 Tag protocol
5.6.2
Command name
NDEF Tag Application Select
Capability Container Select
NDEF Select
System File Select
ReadBinary
UpdateBinary
Table 18. Command set overview
Brief description
Select the NDEF Tag Application
Select the capability container (CC) file using the Select command
Select the NDEF file
Select the system file
Read data from a file
Write new data to a file
Status and error codes
This section lists the status and the error code of the ST25TA16K.
Value
Table 19. Status code of the ST25TA16K
SW1
0x90
SW2
0x00
Comment
Command completed successfully
Length
Value
Value
Value
Value
Value
Table 20. Error codes of the ST25TA16K
SW1 SW2
1 byte
0x62
0x62
0x63
0x63
0x65
1 byte
0x80
0x82
0x00
0xCX
0x81
Comment
File overflow (Le error)
End of file or record reached before reading Le bytes
Password is required
Password is incorrect, X further retries allowed (X can take value 0,1, 2)
Unsuccessful updating
DocID027786 Rev 4
ST25TA16K RF command sets
Length
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Table 20. Error codes of the ST25TA16K (continued)
SW1 SW2
Comment
1 byte 1 byte
0x67 0x00
0x69
0x69
0x69
0x6A
0x6A
0x6A
0x6A
0x6D
0x6E
0x81
0x82
0x84
0x80
0x82
0x84
0x86
0x00
0x00
Wrong length
Command is incompatible with the file structure
Security status not satisfied
Reference data not usable
Incorrect parameters Le or Lc
File or application not found
File overflow (Lc error)
Incorrect P1 or P2 values
INS field not supported
Class not supported
5.6.3 NDEF Application Select command the RF host shall send this command to activate the NDEF Tag Application.
To activate the NDEF Tag Application, the RF host sends the Select command (see
Table 21 ) in addition to the sequence defined in the NFC Forum digital protocol.
Table 21 defines the C-APDU of the Select command to select the NDEF Tag Application
(called NDEF Tag Application Select).
-
Name
Table 21. C-APDU of the NDEF Tag Application Select command
CLA INS P1 P2 Lc Data
0x00 0xA4 0x04 0x00 0x07
0xD27600
00850101
Class byte
Select instruction code
P1 field
P2 field
Number of bytes of data
Application ID
Le field
Le
0x00
Table 22 defines the R-APDU of the NDEF Tag Application Select command.
DocID027786 Rev 4
44
RF command sets ST25TA16K
Length
Value
Value
Value
Table 22. R-APDU of the NDEF Tag Application Select command
Data SW1 SW2 Comment
-
-
-
1 byte
0x90
0x6A
0x6D
1 byte
0x00
0x82
0x00
-
Command completed
NDEF Tag Application not found
Class not supported
The RF host uses the Capability Container Select procedure to select the capability container (CC) file.
The CC file is selected when this command returns "command completed" in the R-APDU.
Table 23 defines the C-APDU of the Select command to select the CC file (called Capability
Container Select).
Name
Table 23. C-APDU of the Capability Container Select command
CLA
-
Class byte
0x00
Select instruction code
P1 field
P2 field
-
Number of bytes of data
CC file ID
INS
0xA4
P1
0x00
P2
0x0C
Lc
0x02
Data
0xE103
Le
-
Table 24 defines the R-APDU of the CC Select command.
Length
Value
Value
Value
Table 24. R-APDU of the Capability Container Select command
Data SW1 SW2 Comment
-
-
-
-
1 byte
0x90
0x6A
0x6D
1 byte
0x00
0x82
0x00
-
Command completed
File or application not found
Class not supported
The RF host uses the NDEF Select command to select the NDEF file.
The NDEF file is selected when this command returns "command completed" in the R-
APDU.
Table 25 defines the C-APDU of the Select command to select the NDEF file (called
NDEF Select).
DocID027786 Rev 4
ST25TA16K
5.6.6
RF command sets
Name CLA
Table 25. C-APDU of the NDEF Select command
-
Class byte
0x00
Select instruction code
P1 field
P2 field
Number of bytes of data
-
0x0001: first NDEF file
INS
0xA4
P1
0x00
P2
0x0C
Lc
0x02
Data
0x000X
Table 26 defines the R-APDU of the NDEF Select command.
Length
Value
Value
Data
Table 26. R-APDU of the NDEF Select command
SW1 SW2 Comment
-
-
-
1 byte
0x90
0x6A
1 byte
0x00
0x82
-
Command completed
File or application not found
Le
-
System File Select command
The RF host uses this command to select the system file.
The System file is selected when this command returns "command completed" in the R-
APDU.
Table 27 defines the C-APDU of the command to select the System file (called System
Select).
Name
Table 27. C-APDU of the System File Select command
CLA
-
Class byte
0x00
Select instruction code
P1 field
P2 field
Number of bytes of data
-
System file ID
INS
0xA4
P1
0x00
P2
0x0C
Lc
0x02
Data
0xE101
Le
-
DocID027786 Rev 4
44
RF command sets ST25TA16K
Table 28 defines the R-APDU of the System File Select command.
Length
Value
Value
Table 28. R-APDU of the System File Select command
Data SW1 SW2 Comment
-
-
1 byte
0x90
0x6A
1 byte
0x00
0x82
-
Command completed
Capability container not found, no data is returned
On receiving the ReadBinary command, the ST25TA16K reads the requested memory field and sends back its value in the R-APDU response.
Before sending a ReadBinary command, a file shall be selected by using a Select command.
The Response of the ReadBinary command is successful when the data to be read is within the selected file
(a)
; in other words, when the sum of P1-P2 and Le fields is equal to or lower than the selected file length.
Table 29 defines the ReadBinary command.
Name
Table 29. C-APDU of the ReadBinary command
CLA INS P1 & P2
-
Class byte
0x00
Read instruction code
-
Offset in the file selected
0xB0
-
Number of bytes to read between
0x01 ≤ Le ≤ max(Selected File length, 0xF6)
2 bytes
Lc
-
Data
-
Le
1 byte
Table 30 defines the R-APDU of the ReadBinary command.
Length
Value
Table 30. R-APDU of the ReadBinary command
Data SW1 SW2 Comment
-
Content read
1 byte
0x90
1 byte
0x00
-
Command completed
a. For more details about CC file, refer to
Section 3.1.2: CC file layout .
For more details about NDEF file, refer to
Section 3.1.3: NDEF file layout
.
For more details about System file, refer to Section 3.1.4: System file layout .
DocID027786 Rev 4
ST25TA16K
Value
Value
Value
Value
RF command sets
Table 30. R-APDU of the ReadBinary command (continued)
Data SW1 SW2 Comment
-
-
-
0x67
0x69
0x6A
0x6E
0x00
0x82
0x82
0x00
Wrong length
Security status not satisfied
File or application not found
Class not supported
Note:
On receiving the UpdateBinary command, the ST25TA16K writes the data field into the selected file and sends back a status in the R-APDU response.
Before sending an UpdateBinary command, a file shall be selected by issuing a Select command.
Table 31 defines the UpdateBinary command.
Name
Table 31. C-APDU of the UpdateBinary command
CLA INS P1 & P2 Lc Data
2 bytes 1 byte Lc bytes -
Class byte
0x00
Write instruction code
0xD6
-
Offset in the file selected
Number of bytes of data (0x01 ≤ ≤
Data to write in the ST25TA16K memory
Le
-
Length
Value
Value
Value
Value
Value
Value
Table 32 defines the R-APDU of the UpdateBinary command.
Table 32. R-APDU of the UpdateBinary command
Data SW1 SW2 Comment
-
-
-
-
-
-
-
1 byte
0x90
0x65
0x67
0x69
0x6A
0x6E
1 byte
0x00
0x81
0x00
0x82
0x82
0x00
-
Command completed
Unsuccessful updating
Wrong length
Security status not satisfied
File or application not found
Class not supported
For further return codes and definitions, refer to Status and error codes
.
DocID027786 Rev 4
44
RF command sets
5.7 ISO/IEC 7816-4 commands
ST25TA16K
The ISO/IEC 7816-4 command set offers some extended features such as the protection of the NDEF file. This command set is used to manage the right access of the NDEF file.
The Verify command has two functions:
1.
Check if a password is required to access to the NDEF file (the LC field = 0x00).
2. Check that the password embedded in the Verify command allows the access to the memory (the Lc field = 0x10 and the password is present).
When the Lc field if equal to 0x00, the verify command returns a success code (0x90 00) provided that the access to the NDEF file does not require a password. When the access to the NDEF file is protected, the response to the Verify command returns an error code
(0x63 00).
When the Lc field equals 0x10, on receiving the Verify command, the ST25TA16K compares the requested password with the data contained in the request and reports whether the operation has been successful in the response.
Before sending this command, an NDEF file shall be selected by issuing the NDEF Select command. Thus, this command checks the right access condition of the last NDEF file selected.
After a successful command, an access is granted for the whole NDEF file.
Table 33 defines the Verify command.
Name CLA
Table 33. Verify command format
INS P1 & P2
0x00 0x20
Class byte
Instruction code
Password identification
0x0001: Read NDEF password transmit
0x0002: Write NDEF password transmit
Other: RFU
0x00: the password is not present
0x10: the password is present in the data field
-
Password
2 bytes
Lc
1 byte
Data
Lc bytes
Le
-
DocID027786 Rev 4
ST25TA16K
5.7.2
RF command sets
Table 34 defines the R-APDU of the Verify command.
Data
Table 34. R-APDU of the Verify command
SW1 SW2 Comment
Length
Value
Value
Value
Value
Value
Value
Value
Value
-
-
-
-
-
-
-
-
-
1 byte
0x90
0x69
0x69
0x69
0x6A
0x63
0x63
0x6E
1 byte -
0x00 Command completed, the password is correct
0x85
The conditions of use are not satisfied (e.g. no
NDEF file was selected)
0x81
0x82
0x80
0x00
Command incompatible with file structure
Security status not satisfied
Incorrect parameter in command data field
A password is required
0xCX
0x00
(1)
The password transmitted is incorrect and X encodes the number of further allowed retries.
Class not supported
1. At each session, the RF host can check a password 3 times.
Change Reference Data command
The Change Reference Data command replaces the read or write password related to the
NDEF files previously selected. It can be performed only if the security status satisfies the security attributes for this command.
Before sending this command, the verify command with the correct NDEF write password shall be issued. Thus, this command changes the reference data of the NDEF file.
Table 35 defines the Change Reference Data command.
Name
Table 35. Change reference data command format
CLA INS P1 & P2
-
Class byte
0x00 0x24
Instruction code
Password identification
0x0001: Read password transmit
0x0002: Write password transmit
Other: RFU
0x10: the password is present in the data field
-
NDEF file Password
2 bytes
Lc
1 byte
Data
Lc bytes
Le
-
DocID027786 Rev 4
44
RF command sets ST25TA16K
Length
Value
Value
Value
Value
Value
Value
Value
Value
Table 36 defines the R-APDU of the Change Reference Data command.
Table 36. R-APDU of the Change Reference Data command
Data SW1 SW2 Comment
-
-
-
-
-
-
-
0
-
1 byte
0x90
0x69
0x65
0x69
0x6A
0x6A
0x6A
0x6E
1 byte -
0x00 Command completed, the access right has been changed
0x81 Command is incompatible with the file structure
0x81 Unsuccessful updating
0x82 Security status not satisfied
0x80 CC file or System file selected
0x82 File or application not found
0x86 Incorrect P1 or P2 values
0x00 Class not supported
5.7.3 Enable Verification Requirement command
The Enable Verification Requirement command activates the protection by password of the
NDEF file. When this command is successful, the read or write access to the NDEF file is protected by a 128-bit password. It can be performed only if the security status satisfies the security attributes for this command.
This command can update the right access of the NDEF file by writing into the EEPROM. In this case, the response timing will be around 5 ms.
Before sending this command, the verify command with the correct NDEF write password shall be issued. Thus, this command changes the access right of the NDEF file.
Table 37 defines the Enable Verification requirement command.
Name
Table 37. Enable Verification Requirement command format
CLA INS P1 & P2
-
-
-
0x00 0x28 2 bytes
Class byte
Instruction code
New security attributes
0x0001: Enable the read protection of the NDEF file
0x0002: Enable the write protection of the NDEF file
Other: RFU
Lc
-
Data
-
Le
-
The last five bits identify the password sent in the Verify command.
DocID027786 Rev 4
ST25TA16K RF command sets
Table 38 defines the R-APDU of the Enable Verification Requirement command.
Length
Value
Value
Value
Value
Value
Value
Table 38. R-APDU of the Enable Verification Requirement command
Data SW1 SW2 Comment
-
-
-
-
-
0
-
1 byte
0x90
0x69
0x69
0x6A
0x6A
0x6A
1 byte
0x00
0x81
0x82
0x80
0x82
0x86
-
Command completed, the password is correct
Command is incompatible with the file structure
Security status not satisfied
CC file or System file selected
File or application not found
Incorrect P1 or P2 values
5.7.4 Disable Verification Requirement command
The Disable Requirement command deactivates the protection by password of the NDEF file. When this command is successful, the read or write access to the NDEF file is granted without security requirements. It can be performed only if the security status satisfies the security attributes for this command.
Before sending this command, the Verify command with the correct NDEF write password shall be issued. Thus, this command changes the access right of the NDEF file.
This command can update the right access of the NDEF file by writing into the EEPROM. In this case, the response timing will be around 6 ms.
Table 39 defines the Disable Verification Requirement command.
Name
Table 39. Disable Verification Requirement command format
CLA INS P1 & P2
-
Class byte
Instruction code
0x00 0x26 2 bytes
-
-
-
New security attributes
0x0001: Disable the read protection of the NDEF file
0x0002: Disable the write protection of the NDEF file
Other: RFU
Lc
-
Data
-
Le
-
DocID027786 Rev 4
44
RF command sets ST25TA16K
Table 40 defines the R-APDU of the Disable Verification Requirement command.
Length
Value
Value
Value
Value
Value
Value
Value
Value
Table 40. R-APDU of the Disable Verification Requirement command
Data SW1 SW2 Comment
-
-
-
-
-
-
-
0
-
1 byte
0x90
0x69
0x69
0x6A
0x6A
0x6A
0x6E
0x65
1 byte
0x00
0x81
0x82
0x80
0x82
0x86
0x00
0x81
-
Command completed, the password is correct
Command is incompatible with the file structure
Security status not satisfied
CC file or System file selected
File or application not found
Incorrect P1 or P2 values
Class not supported
Update failed
5.8 ST proprietary command set
The RF host can be issued with the command set described in this section.
On receiving the ExtendedReadBinary command, the ST25TA16K reads the requested memory field and sends back its value in the R-APDU response.
Before sending an ExtendedReadBinary command, a file shall be selected by issuing an
NDEF select command.
The response of the ExtendedReadBinary command will be successful even if the data to be read is beyond the NDEF message. The command returns an error code if the data to be read goes beyond the end of the file.
Name
Table 41. C-APDU of the ExtendedReadBinary command
CLA INS P1 & P2
Length
ST Class byte
0xA2 0xB0 2 bytes
-
Read instruction code
Offset in the file selected
-
Number of bytes to read between 0x01 ≤ Le ≤ 0xF6
Lc
-
Data
-
Le
1 byte
Table 42 defines the R-APDU of the read binary command.
DocID027786 Rev 4
ST25TA16K RF command sets
Length
Value
Value
Value
Value
Value
Value
Table 42. R-APDU of the ExtendedReadBinary command
Data SW1 SW2 Comment
Le bytes
Content read
-
-
-
-
-
1 byte
0x90
0x67
0x69
0x6A
0x6A
0x6E
1 byte
0x00
0x00
0x82
0x82
0x86
0x00
-
Command completed
Wrong length
Security status not satisfied
File or application not found
Incorrect P1 or P2 values
Class not supported
The command configures the NDEF file to the ReadOnly or to the WriteOnly State.
This command can update the right access to the NDEF file by writing into the EEPROM. In this case, the response timing will be around 6 ms.
Table 43 defines the EnablePermanentState requirement command.
Name
Table 43. EnablePermanentState command format
CLA INS P1 & P2
-
-
Length
Class byte
0xA2 0x28 2 bytes
-
Instruction code
New security attributes
0x0001: Enable the read protection of the NDEF file
0x0002: Enable the write protection of the NDEF file
Other: RFU
Lc
-
Data
-
Le
-
Table 44 defines the R-APDU of the EnablePermanentState command.
Length
Value
Value
Value
Value
Table 44. R-APDU table of the EnablePermanentState command
Data SW1 SW2 Comment
-
-
-
-
-
1 byte
0x90
0x65
0x67
0x69
1 byte
0x00
0x81
0x00
0x82
-
Command completed
Update failed
Wrong length
Security status not satisfied
DocID027786 Rev 4
44
RF command sets ST25TA16K
Value
Value
Value
Value
Table 44. R-APDU table of the EnablePermanentState command (continued)
Data SW1 SW2 Comment
-
-
-
0x6A
0x6A
0x80
0x82
0x6A 0x86
0x6E 0x00
CC file or System file selected
File or application not found
Incorrect P1 or P2 values
This command allows the user to modify the file type of a selected file to Proprietary file
(0x05) or NDEF file (0x04).
The command is executed only when the application and the file are selected and the file length and access right have previously been set to 0X00h (message invalid, all access rights granted).
This command will update the file type located in the CC file by writing in the EEPROM. In this case the response timing will be approximately 6 ms.
Table 45 defines the UpdateFileType command.
Name CLA
Length
Class byte
0xA2
Instruction code
P1 field
P2 field
Number of data bytes
-
File type
Table 45. UpdateFileType command format
INS P1 P2 Lc
0xD6 0x00 0x00 0x01
Data
0x04 or 0x05
Le
-
Table 46 defines the R-APDU of the UpdateFileType command.
Length
Value
Value
Value
Value
Value
Table 46. R-APDU table of the UpdateFileType command
Data SW1 SW2 Comment
-
-
-
-
-
-
1 byte
0x90
0x69
0x6A
0x6A
0x6A
1 byte
0x00
0x82
0x80
0x82
0x86
-
Command completed
Security status not satisfied
CC file or System file selected
File or application not found
Incorrect P1 or P2 values
DocID027786 Rev 4
ST25TA16K RF command sets
Value
Value
Table 46. R-APDU table of the UpdateFileType command (continued)
Data SW1 SW2 Comment
-
0x6A 0x86
0x6E 0x00
Incorrect P1 or P2 values
5.9
5.9.1
Specific RF command set
This section describes the command set that can be issued only by the RF host.
Anticollision command set
Table 47 lists the commands that can be issued only by the RF host. The format of these
commands is described in the NFC Forum Digital Protocol specification.
Table 47. Commands issues by the RF host
Family command set Command name Instruction code
NFC-A technology
ALL_REQ
SENS_REQ
SDD_REQ
SEL_REQ
SLP_REQ
0x52
(1)
0x26
0x93 or 0x95 or 0x97
0x93 or 0x95 or 0x97
0x50
1. Code on 7 bits.
Note: In response to a SDD_REQ Command with a SEL_PAR value equal to 20h, the
ST25TA16Ks in the Operating Field transmit the requested cascade level of their NFCID1
(NFCID1 CLn, with n = 1 or 2). The NFCID1 of the ST25TA16K consists of 7 bytes. The length of the Response containing a complete NFCID1 cascade level (i.e., NFCID1 CL1, or
NFCID1 CL2) is always 5 bytes. The coding of the Response depends on the value of the
SEL_CMD byte and the size of the NFCID1.Refer to the example in
details.
Command
SDD_REQ 1
SEL_REQ 1
SENS_REQ or
ALL-REQ
Code
26
52
93 20
Table 48. Example of anticollision sequence
Comment
-
NVB 20
Number Valid bit
(2 bytes Code & NVB)
Response
ATQA
-
Code Comment
42 00
UID double size bit frame anticollision
CT uid1 uid2 uid3
BCC
CT Cascade Tag “0x88” (UID
7bytes)
BCC Block Check Character
(XOR previous Bytes)
93 70 CT uid1 uid2 uid3
BBC
NVB 70
(cmd NVB Uid lower bytes)
CT Cascade Tag “0x88”
SAK & CRC 04 DAD7 UID Not complete
DocID027786 Rev 4
44
RF command sets ST25TA16K
Command
SDD_REQ 2
SEL_REQ 1
Table 48. Example of anticollision sequence (continued)
Code Comment
95 20
NVB 20
Number Valid bit
(2 bytes Code & NVB)
95 70 uid4 uid5 uid6 uid7
BBC
NVB 70
(cmd NVB Uid Upper bytes)
Response
-
Code Comment uid4 uid5 uid6 uid7
BCC
(UID 7bytes)
BCC Block Check Character
(XOR previous Bytes)
SAK & CRC 20 FC70 UID complete
RATS command and ATS response are used for NFC Forum Type 4A Tag Platform Device
Activation (as defined in NFC Forum Digital Protocol specification).
Table 49 details the RATS command. This command shall be sent after the anticollision
process.
Name
Byte field
Bit field
Instruction code
FSDI
DID (0 ≤ DID ≤ 14)
2 CRC bytes
INS
0xE0
Table 49. RATS command
Param
1 byte
b7-b4 b3-b0
CRC
2 bytes
-
The FSDI field codes the FSD, which defines the maximum size that an RF host is able to receive.
Table 50 gives the conversion from FSDI to FSD.
FSDI 0x0
FSD 16
0x1
24
Table 50. Conversion from FSDI to FSD
0x2 0x3 0x4 0x5 0x6 0x7 0x8
32 40 48 64 96 128 256
0x9h-
0xE
RFU
0xF
256
The DID (Dynamic ID, optionally affected to the ST25TA16K by the host to address
ST25TA16K in all commands) field defines the value of the addressed ST25TA16K. If DID is not ‘0’, the ST25TA16K will ignore the command if it contains a DID different from the one affected to it during RATS.
DocID027786 Rev 4
ST25TA16K RF command sets
Name TL T0
Table 51. ATS response
TA(1)
Byte field 0x05 0x78 1 byte
Bit field -
Length of the ATS response
FSCI = 256 bytes
The maximum ascending data rate is 106 kbps
The maximum descending data rate is 106 kbps
FWI field (155 ms when TB = 0x90)
SFGI field (302 µs when TB = 0x90)
The DID is supported
2 CRC bytes
TB(1) b8-b5
1 byte b4-b1
TC(1)
0x02
-
CRC
2 bytes
-
The FSCI codes the FSC, which stands for the maximum frame size that the ST25TA16K is able to receive. The ST25TA16K is able to receive up to 256 bytes of command. If the RF host sends a command with more than 256 bytes, the ST25TA16K will not be able to treat the command and will not reply.
The FWI (Frame Waiting time Integer) codes the FWT, which stands for the Frame Waiting
Time. This time corresponds to the maximum duration while an RF host shall send before sending the next command.
The SFGI codes the SFGT, which stands for the Start-up Frame Guard Time. This is the minimum time that the reader shall wait after receiving the response of the ST25TA16K.
DocID027786 Rev 4
44
RF command sets ST25TA16K
PPS (Protocol and Parameter Selection) command and response are defined in ISO/IEC
14443-4, in the Protocol Activation of PICC Type A.
The PPS command allows to change the data rates of the ascending (RF host to
ST25TA16K) and descending (ST25TA16K to RF host) data rates.
Name
Byte field
Bit field b7-b4
-
INS
Instruction code
DID
PPS1 is present -
RFU
PPS1 Descending data rate
Ascending data rate
2 CRC bytes
INS
0xDX
Table 52. PPS command
PPS0
0x11 b3-b0 0b0000
PPS1
1 byte b3-b2 b1-b0
CRC
2 bytes
-
The ascending and descending data rates shall be coded as described in
Value
Data rate
Table 53. Ascending and descending data rate coding
0b00 0b01 0b10
106 kbps RFU RFU
0b11
RFU
When the ST25TA16K is able to change both data rates, it returns the response detailed in
Table 54 . The data rate of this response is 106 kbps; then, the ST25TA16K changes the
ascending and descending data rates.
Name
Byte field
Bit field
Response code
DID field
2 CRC bytes
Table 54. PPS response
INS -
0xDX b8-b5 b4-b1
PPS0
0x11
-
DocID027786 Rev 4
ST25TA16K
6 RF device operation
6.1
RF device operation
Anticollision and Device Activation command set for the RF interface
The ST25TA16K device supports the command set defined in the NFC-A Technology and the Type 4A Tag Platform chapters of the NFC Digital Protocol V1.0 specification.
6.2 Open an RFsession
Once the RF host has terminated the anticollision procedure and retrieve the ATS response, it shall send the SelectApplication command. The ST25TA16K will open an RF session. At this point, the RF host can send the applicative command set.
6.3
6.4
Close an RFsession
The RF host can close the RF session by issuing one of these methods:
• send an S(DES) command
• turn off the RF field
Applicative command set
The applicative command set is composed of the following command sets:
• the NFC Forum Type 4 Tag command set
• the ISO/IEC 7816-4 command set
• the proprietary command set
DocID027786 Rev 4
44
Functional procedures ST25TA16K
7.1
7.2
7.3
7.4
This section describes procedures to access the memory or to manage its protection.
Selection of an NDEF message
The RF host shall use this procedure to detect the NDEF message inside an ST25TA16K.
The NDEF detection procedure is as follows:
1.
Open an RF session
2. Send the SelectNDEFTagApplication command
3. Select the CC file
4. Read the CC file
5. Select the NDEF file.
Reading of an NDEF message
The RF host executes the NDEF read procedure to read the NDEF file.
1.
Detect successfully the NDEF file using the NDEF detection procedure
2. Check that the read access without any security is granted for the NDEF file from the information provided by the CC file
3. Select the NDEF file
4. Read the NDEF file.
Reading a locked NDEF file
The RF host executes this procedure to read an NDEF file that has been locked previously.
1.
Select the NDEF Tag Application
2. Select the NDEF file
3. Verify the Read password by using the Verify command
4. Read the data in the NDEF file.
Locking an NDEF file
The RF host executes this procedure to protect an NDEF file.
1.
Select the NDEF Tag Application
2. Check the right access provided by the CC file
3. Select the NDEF file
4. Transmit the NDEF file Write password by using the Verify command
5. Lock the NDEF file by sending the Enable verification command.
DocID027786 Rev 4
ST25TA16K
7.5
Functional procedures
Unlocking an NDEF file
The RF host executes this procedure to read an NDEF file that has been locked previously.
1.
Select the NDEF Tag Application
2. Select the NDEF file
3. Verify the NDEF file Write password by using the Verify command
4. Unlock the NDEF file by sending the Disable verification command
7.6 Reaching the read-only state for an NDEF file
The RF host executes this procedure to read an NDEF file that has been locked previously.
1.
Select the NDEF Tag Application
2. Select the NDEF file
3. Transmit the NDEF file Write password using the Verify command
4. Send an EnablePermanentState command
7.7
7.8
Creating or updating an NDEF file
1.
Select the NDEF Tag Application
2. Select the NDEF file
3. Set the File Length to 0x00 using the UpdateBinary command
4. Write NDEF message content using the UpdateBinary command
5. Set the new File Length (must be always two written bytes), and elect the NDEF Tag
Application
Changing the file type (applicable only on file 0x0001)
The RF host executes this procedure to change the File Type of a file for which all access rights were previously granted.
1.
Select the NDEF Tag Application
2. Select the file 0x0001
3. Set the File Length to 0x00 using the UpdateBinary command
4. Send an UpdateFileType command with the New file Type as data.
DocID027786 Rev 4
44
UID: Unique identifier ST25TA16K
The ST25TA16K is uniquely identified by a 7 bytes unique identifier (UID). The UID is a read-only code and comprises:
• The IC manufacturer code on 1 byte (0x02 for STMicroelectronics).
• The Product code on 1 byte.
• A device number on 5 bytes.
Table 55 describes the UID format.
Table 55. UID format
0x02 0xC5 5 bytes
IC manufacturer code
ST25TA16K product code
Device number
DocID027786 Rev 4
ST25TA16K Maximum ratings
Stressing the device above the ratings listed in
may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the operating sections of this specification is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect the device reliability.
Symbol
T
A
T
STG t
STG
Table 56. Absolute maximum ratings
Parameter Min.
Ambient operating temperature
Storage temperature
Storage time
Sawn wafer on
UV tape (kept in its original packing form)
-40
15
-
Max.
85
25
9
(1)
Unit
°C
°C months
V
V
I
T
STG t
STG
CC
(3)
MAX_1
MAX_2
V
V
ESD
ESD
Storage temperature
Storage time
Sawn bumped wafer (kept in its antistatic bag)
RF supply current AC0 - AC1
RF input voltage amplitude between AC0 and AC1,
GND pad left floating
VAC0-VAC1
AC voltage between AC0 and GND, or AC1 and GND
VAC0-GND or
VAC1-GND
Electrostatic discharge voltage
(human body model)
(4)
AC0-AC1
Electrostatic discharge voltage
(Machine model)
15
-
-
-
-0.5
-
-
25
9
(2)
100
10
4.5
1000
200
1. Counted from ST shipment date.
2. Counted from ST production (taping) date.
3. Based on characterization, not tested in production. Maximum absorbed power = 100 mW at 7.5 A/m.
4. AEC-Q100-002 (compliant with JEDEC Std JESD22-A114A, C1 = 100 pF, R1 = 1500 Ω , R2 = 500 Ω ).
°C months mA
V
V
V
V
DocID027786 Rev 4
44
RF electrical parameters
10 RF electrical parameters
ST25TA16K
This section summarizes the operating and measurement conditions, and the DC and AC characteristics of the device in RF mode.
The parameters in the DC and AC characteristics tables that follow are derived from tests performed under the Measurement Conditions summarized in the relevant tables.
Designers should check that the operating conditions in their circuit match the measurement conditions when relying on the quoted parameters.
Symbol
T
A
Table 57. Default operating conditions
Parameter Min.
Ambient operating temperature –40
Max.
85
Unit
°C
Symbol Parameter
Table 58. RF characteristics
(1)
Condition Min Typ Max Unit f
C
H_ISO
H_Extended
External RF signal frequency
Operating field according to ISO
Operating field in extended temperature range
T
T
A
A
-
= 0 °C to 50 °C
= -40 °C to 85 °C
13.553
1500
13.56
-
-
13.567
7500
7500
MI
CARRIER t
1 t
2 t
3 t
4
100% carrier modulation index
Pause A length
Pause A low time
Pause A rise time
Pause A rise time section
MI=(A-B)/(A+B)
-
-
-
-
90
28/f
C
7/f
C
1.5xt4
0
-
-
-
-
t
MIN CD
Minimum time from carrier generation to first data
From H-field min -
W t
RF write time (including internal
Verify) for one page
Internal tuning capacitor in SO8
(2)
6
C
TUN t
RF_OFF
RF OFF time f
C
= 13.56 MHz
Chip reset
22.5
-
25
-
1. All timing characterizations were performed on a reference antenna with the following characteristics:
External size: 75 mm x 48 mm
Number of turns: 6
Width of conductor: 0.6 mm
Space between two conductors: 0.6 mm
Value of the tuning capacitor in SO8: 25 pF (ST25TA16K)
Value of the coil: 5 µH
Tuning frequency: 14.2 MHz.
2. Characterized only, at room temperature only, measured at VAC0-VAC1 = 1 V peak to peak, at 13.56 MHz.
100
40.5/f
C t1
16/f
6/f
5
-
27.5
5
C
C
MHz mA/m mA/m ms ms pF ms
%
µs
µs
µs
µs
DocID027786 Rev 4
ST25TA16K Ordering information
Device type
ST25 = RF memory
Table 59. Ordering information scheme for packaged devices
ST25 T A
Product Type
T = Tags + RFID
Protocol
A = ISO14443-A
Memory density
16K (binary)
Interface
A = None
Features
B = Basic features (no option)
Operating temperature
6 = -40 o
C to +85 o
C
Package / Packing
G = Bumped 120 µm
Capacitor value
3 = 25 pF
Note: Parts marked as “ES”, “E” or accompanied by an Engineering Sample notification letter, are not yet qualified and therefore not yet ready to be used in production and any consequences deriving from such usage will not be at ST charge. In no event, ST will be liable for any customer usage of these engineering samples in production. ST Quality has to be contacted prior to any decision to use these Engineering samples to run qualification activity.
DocID027786 Rev 4 45/45
45
Revision history ST25TA16K
Date
05-May-2015
31-Aug-2016
21-Oct-2016
16-Feb-2017
Revision
Table 60. Document revision history
Changes
1
2
3
4
Initial release.
Updated Description and image on Cover page.
Updated Figure 2: Changing the read access right to an NDEF file and
Figure 3: Changing the write access right to an NDEF file .
Added Section 5.8.3: UpdateFileType command
.
Updated Section 5.9.2: RATS command and ATS response ,
Section 5.9.3: PPS command and response ,
Section 7.6: Reaching the read-only state for an NDEF file , Section 7.7: Creating or updating an
NDEF file and Section 7.8: Changing the file type (applicable only on file
.
Updated Table 9: RF command sets
Table 41: C-APDU of the ExtendedReadBinary command and
Table 59: Ordering information scheme for packaged devices
.
Updated Table 56: Absolute maximum ratings and added footnote 2 .
Updated title of
Table 50: Conversion from FSDI to FSD and of
Section 11: Ordering information .
,
Section 3.4: NDEF file passwords
,
and Section 5.9.2: RATS command and ATS response .
Updated Table 4: CC file layout for one NDEF file ,
Table 5: NDEF file layout and Table 6: Field list
.
Added Table 48: Example of anticollision sequence .
Removed former footnote 1
Updated footnote
of
.
DocID027786 Rev 4
ST25TA16K
IMPORTANT NOTICE – PLEASE READ CAREFULLY
STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on
ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at the time of order acknowledgement.
Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or the design of Purchasers’ products.
No license, express or implied, to any intellectual property right is granted by ST herein.
Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product.
ST and the ST logo are trademarks of ST. All other product or service names are the property of their respective owners.
Information in this document supersedes and replaces information previously supplied in any prior versions of this document.
© 2017 STMicroelectronics – All rights reserved
DocID027786 Rev 4 47/47
47
ડાઉનલોડ કરો
જાહેરાત