Gefen EXT-DPKVM-841 User manual

Add to My manuals
33 Pages

advertisement

Gefen EXT-DPKVM-841 User manual | Manualzz

®

8x1 DPKVM

Switcher

EXT-DPKVM-841

User Manual

www.gefen.com

Technical Support:

ASKING FOR ASSISTANCE

Technical Support Hours:

8:00 AM to 5:00 PM Monday thru Friday.

Write To:

Gefen, LLC c/o Customer Service

20600 Nordhoff St

Chatsworth, CA 91311 www.gefen.com

[email protected]

Notice

Gefen, LLC reserves the right to make changes in the hard ware, packaging, and any accompanying doc u men ta tion without prior written notice.

8x1 DPKVM Switcher is a trademark of Gefen, LLC

© 2012 Gefen, LLC. All rights reserved.

All trademarks are the property of their respective owners.

Rev A4

CONTENTS

1 Introduction

3 Features

4 Front Panel Layout

5 Front Panel Descriptions

6 Back Panel Layout

7 Back Panel Descriptions

8 IR Remote Control Unit

8 Layout and Description

9 Installing the Battery

10 Setting the IR Channel

11 Connecting the 8x1 DPKVM Switcher

11 Wiring

12 Operating the 8x1 DPKVM Switcher

12 Front Panel Buttons and LED Indicators

12 Switching sources using the front-panel buttons

12 Switching sources using the IR Remote Control Unit

13 Switching sources using RS-232

13 Switching sources using Telnet

15 IP

20 General

23 Routing

27 Rack Ear Installation

28 Specifi cations

29 Warranty

INTRODUCTION

Congratulations on your purchase of the 8x1 DPKVM Switcher. Your complete satisfaction is very important to us.

Gefen

Gefen delivers innovative and progressive computer and electronics add-on solutions that harness integration, extension, distribution, and conversion technologies. Gefen’s reliable plug-and-play products supplement cross-platform computer systems, professional audio/video environments, and HDTV systems of all sizes with hard-working solutions that are easy to install and simple to operate.

The Gefen 8x1 DPKVM Switcher

Easily switch between eight computers using DisplayPort with the Gefen 8x1

DPKVM Switcher.

The rack-mountable Gefen 8x1 DPKVM Switcher offers an economical solution for switching between eight different computers to one display location.

In addition, USB peripherals and audio are carried at the same time from each source making this a very versatile solution.

Eliminating the need to purchase many displays, keyboards, and other accessories for each computer in a studio or professional environment, this versatile solution saves money, supports both Mac and PC-type computers, and offers uncluttered and increased desktop space.

The 8x1 DPKVM Switcher outputs are: One DisplayPort, two USB 2.0 ports

(used for keyboard, mouse and other USB 2.0 peripherals) and an analog L/R audio. This Switcher can be controlled using front-panel discrete switching, IP control, the included IR Remote control, or the RS-232 port for switching automation.

The 8x1 DPKVM Switcher is compatible with all operating systems using Display-

Port and USB.

How It Works

Connect the eight included 6 foot DisplayPort cables between the computers and the Switcher inputs. Connect the eight included USB cables between the computers and the USB inputs. Connect the eight included audio cables between the computers and the audio inputs. Connect the Switcher output to the monitor using a DisplayPort cable. Connect the Switcher USB outputs to the USB peripherals. Connect the Switcher audio cables to the audio devices. Connect the included 5V DC locking power supply to the 8x1 Switcher and connect the AC power cord to an available electrical outlet. The currently selected source will be displayed

1

OPERATION NOTES

READ THESE NOTES BEFORE INSTALLING OR

OPERATING THE 8X1 DPKVM SWITCHER

• The 8x1 DPKVM Switcher supports Pass-through EDID. The Switcher will use the EDID from the currently active input.

• Dual Link resolutions up to 2560 x 1600 are supported.

• HDCP content is not supported.

• This Switcher does not support DHCP.

• The default IR channel for both the Switcher and the IR Remote Control Unit is channel 0. See page 10 for more information.

2

FEATURES

Features

• Switches between eight DisplayPort sources with USB 2.0 and Audio to one display, keyboard, and mouse

• Supports resolutions up to 2560 x 1600

• Supports DisplayPort version 1.1a

• Green mode (low power consumption when DP source is not present)

• Firmware upgrade via RS-232 or Ethernet

• IR remote control

• Supports USB 2.0 with backward-compatibility for USB 1.1

• Standby Feature (Green Mode)

• Jack for external IR Receiver (EXT-RMT-EXTIR)

• Save space on your desktop

• Rack-mountable

Package Includes

(1) 8x1 DPKVM Switcher

(8) 6 ft. DisplayPort cables

(8) 6 ft. USB 2.0 cables (A - B)

(8) 6 ft. 3.5 mm mini-stereo audio cables

(1) IR Remote Control Unit

(1) 5V / 4A DC Locking Power Supply

(1) AC Power Cord

(1) Set Rack ears

(1) Quick-Start Guide

3

FRONT PANEL LAYOUT

4

FRONT PANEL DESCRIPTIONS

1 Input Indicators (1 - 8)

Each of these LED indicators glows bright blue according to the input selection

(see Input Buttons, below)

2 IR

Receives IR signals from the included IR Remote Control Unit.

3 Input Buttons (1 - 8)

Pressing each of these buttons selects the desired input source (1 - 8).

4 Power

This LED indicator will glow bright red when the unit is powered.

5

BACK PANEL LAYOUT

6

BACK PANEL DESCRIPTIONS

Connect the included 5V DC locking power supply to this receptacle.

2 In 1 - In 8

Each of these ports will accept a standard DisplayPort source device.

Connect an IR extender cable to this port.

4 USB Out (1 - 2)

Connect USB devices (e.g. mouse devices, keyboards, etc.) to these ports.

5 Ethernet

Use an Ethernet cable to connect the Switcher to a network in order to communicate via Telnet.

6 RS-232 Serial Port

This port is used for serial communication using an RS-232 control device. For details, refer to page 14.

7 USB In (1 - 8)

Connect USB source devices to these ports.

This port will accept a single standard DisplayPort output device. The currently selected DisplayPort input source will be output via this port.

Connect an audio output device to this connectors using a 3.5 mm mini-stereo cable. The audio output will be for the currently selected input source.

10 Audio In (1 - 8)

Connect up to eight (8) audio source devices to these ports using the included

3.5 mm mini-stereo cables.

7

2

IR REMOTE CONTROL UNIT

Layout and Description

1

This LED will be activated momentarily each time a button is pressed.

2 Source Selection Buttons (1 - 8)

These buttons are used to select which source is routed to a monitor.

NOTE: An Activity Indictor that fl ashes quickly while holding down any one of the eight buttons indicates a low battery. Replace the IR Remote

Control battery as soon as possible.

8

IR REMOTE CONTROL UNIT

Installing the Battery

1. Remove the battery cover on the back of the IR Remote Control Unit.

2. Insert the included battery into the open battery slot. The positive (+) side of the battery should be facing up.

3. Replace the battery cover.

The Remote Control unit ships with two batteries. One battery is required for operation and the other battery is a spare.

Battery Slot

WARNING: Risk of explosion if battery is replaced by an incorrect type.

Dispose of used batteries according to the instructions.

9

IR REMOTE CONTROL UNIT

Setting the IR Channel

In the event that IR commands from other remote controls interfere with the supplied IR Remote Control unit, changing the IR Remote Control’s IR channel will fi x the problem. The IR Remote Control unit has a bank of DIP switches used for setting the IR channel. The DIP switch bank is located underneath the battery cover.

Left: Picture of the opened rear battery compartment of the IR remote showing the exposed DIP Switch bank between the battery chambers.

Corresponding DIP Switch Settings for each IR Channel

IR Channel 0

(default)

ON

IR Channel 1

ON

IR Channel 2

ON

IR Channel 3

ON

1 2 1 2 1 2

It is important that the IR channel on the Remote Control unit, matches the IR channel set on the 8x1 DPKVM Switcher. For example, if both DIP switches on the IR Remote Control unit are set to IR channel 0 (both DIP switches down), then the 8x1 DPKVM Switcher must also be set to IR channel 0. See page 21 on how to change the IR channel on the 8x1 DPKVM Switcher.

10

CONNECTING THE 8X1 DPKVM SWITCHER

How to Connect the 8x1 DPKVM Switcher

1 Connect up to eight (8) DisplayPort source devices to the DisplayPort inputs on the back panel of the Switcher using DisplayPort cables.

2 Connect a DisplayPort-supported display to the DisplayPort output on the back panel of the Switcher.

a OPTIONAL: To use the RS-232 communication feature, connect an

RS-232 cable between the Switcher and RS-232 host controller.

b OPTIONAL: To communicate with the Switcher using Telnet, connect an Ethernet cable from the Ethernet jack on the back of the Switcher to the network. See page 24 for more information on using the Telnet feature.

c OPTIONAL: To extend the range of the IR control, connect an IR

Extender (Gefen part no. EXT-RMT-EXTIR) to the back of the Switcher.

3 Connect the included 5V locking power supply to the power receptacle on the 8x1 DPKVM Switcher

4 Connect the opposite end of the power supply to an open wall socket power source.

Wiring Diagram for the 8x1 DPKVM Switcher

Computer

Computer

Computer

Computer

Computer

Computer

Computer

Computer

MINI STEREO AUDIO CABLE

DISPLAYPORT CABLE

RS-232 CABLE

USB CABLE

ETHERNET

IR

IR Extender

DisplayPort KVM Switcher

RS-232 Controller

DisplayPort

Display

USB Mouse

USB Keyboard

Router

Powered Speakers

EXT-DPKVM-841

ATTENTION: This product should always be connected to a grounded electrical socket.

11

OPERATING THE 8X1 DPKVM SWITCHER

Front Panel Buttons and LED Indicators

The front panel of the 8x1 DPKVM Switcher has a set of eight (8) LED indicators, displaying which input (source) is being displayed. Each of these LED indicators corresponds to one of the push-buttons on the front panel.

Switching sources using the front-panel buttons

Example: Switch to input 5 using the front-panel buttons:

1 Press button 5 on the front panel of the 8x1 DPKVM Switcher.

2 The LED indicator for input 5 will glow bright blue on the front panel.

1

2

Switching sources using the IR Remote Control

Example: Switch to Input 1 using the IR Remote Control:

1 Press button 1 on the IR Remote Control Unit. The Activity Indicator on the IR Remote Control Unit will glow yellow, indicating that a button was pressed.

2 The LED indicator for input 1 will glow bright blue.

1

2

12

OPERATING THE 8X1 DPKVM SWITCHER

Switching sources using RS-232

Confi gure the Switch for use with RS-232 (see page 14 for details).

Example: Switch to input 4 using RS-232

1 Use the command r 4 to route the Switcher to Input 4. See page 15 for important information on RS-232 commands. RS-232 commands are case-sensitive.

2 The LED indicator for Input 4 will glow bright blue on the front panel.

1

2 r 4

Route to Input 4

Switching sources using Telnet

Confi gure the Switch for use with Telnet. See page 24 for details.

Example: Switch to Input 2 using the Telnet protocol

1 Use the command r 2 to route the Switcher to Input 2.

2 The LED indicator for Input 2 will glow bright blue.

1

2

Type Cmd: r 2

Route to Input 2

13

RS-232 CONTROL

Only pins 2 (Receive), 3 (Transmit), and 5 (Ground) are used for communication.

A null-modem adapter should not be used with this product.

5 4 3 2 1 1 2 3 4 5

9 8 7 6 6 7 8 9

Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface

Serial Port Settings

Bits per second ............................................................................................ 19200

Data bits ............................................................................................................... 8

Parity ............................................................................................................. None

Stop bits ................................................................................................................1

Flow Control .................................................................................................. None

IMPORTANT: When sending RS-232 commands, a carriage return and a line feed character must be included at the end of each line.

NOTE: Only pins 2 (Receive), 3 (Transmit), and 5 (Ground) are used for communication. A null-modem adapter should not be used with this product.

14

RS-232 COMMANDS

Command Syntax

All RS-232 commands are case-sensitive and must be entered in lowercase.

Each command must be preceded by the ‘#’ character. A carriage return must also be appended to every command.

Example:

#set_http_port 80[CR]

IP Confi guration

Command

#get_pass

#get_user_name

#ipconfi g

#rstip

#set_http_port

#set_pass

#set_telnet_port

#set_user_name

#sgateway

#sipadd

#snetmask

#use_telnet_pass

Description

Prompts for the Telnet password

Prompts for the Telnet username

Displays all TCP/IP settings

Sets IP confi guration to default settings

Sets the Web server listening port

Sets the Telnet password

Sets the Telnet listening port

Sets the Telnet user name

Specifi es the new gateway

Specifi es a new IP address

Specifi es a new net mask

Toggles Telnet password prompt

#GET_PASS Command

The #GET_PASS command prompts for the Telnet password.

Syntax:

#get_pass

Parameters:

None

15

RS-232 COMMANDS

#GET_USER_NAME Command

The #GET_USER_NAME command prompts for the Telnet username.

Syntax:

#get_user_name

Parameters:

None

#IPCONFIG Command

The #IPCONFIG command displays all TCP/IP settings.

Syntax:

#ipconfi g

Parameters:

None

#RSTIP Command

The #RSTIP command resets the IP confi guration to the default settings.

Syntax:

#rstip

Parameters:

None

16

RS-232 COMMANDS

#SET_HTTP_PORT Command

The #SET_HTTP_PORT command sets the Web server listening port.

Syntax:

#set_http_port param1

Parameters: param1

#SET_PASS Command

The #SET_PASS command sets Telnet password.

Syntax:

#set_pass param1

Parameters: param1

String

Notes:

The maximum length of the password string is 20 characters.

#SET_TELNET_PORT Command

The #SET_TELNET_PORT command sets the Telnet server listening port.

Syntax:

#set_telnet_port param1

Parameters: param1

17

RS-232 COMMANDS

#SET_USER_NAME Command

The #SET_USER_NAME command sets the Telnet user name.

Syntax:

#set_user_name param1

Parameters: param1

String

Notes:

The maximum length of the username string is 20 characters.

#SGATEWAY Command

Specifi es the new IP gateway. Dot-decimal notation must be used when specifying the IP address. A reboot is required after the new IP gateway address has been assigned.

Syntax:

#sgateway param1.param2.param3.param4

Parameters:

Example:

#sgateway 192.168.1.1

18

RS-232 COMMANDS

#SIPADD Command

The #SIPADD command specifi es a new IP address. Dot-decimal notation must be used when specifying the IP address. A reboot is required after the new IP address is set.

Syntax:

#sipadd param1.param2.param3.param4

Parameters: param2

IP address [0 - 255]

Example:

#sipadd 192.168.2.240

#SNETMASK Command

The #SNETMASK command specifi es a new net mask. Dot-decimal notation must be used when specifying the IP address. A reboot is required after the new

IP address is set.

Syntax:

#snetmask param1.param2.param3.param4

Parameters: param2

IP address [0 - 255]

Example:

#snetmask 255.255.255.0

19

RS-232 COMMANDS

#USE_TELNET_PASS Command

The #USE_TELNET_PASS command enables / disabled the use of a Telnet password during the login process.

Syntax:

#use_telnet_pass param1

Parameters: param1

Value

0

1

Meaning

Disable password

Enable password

General Commands

Command

#activebolo

#fadefault

#irrmtadd

#lockpower

#stbymode

Description

Activates the bootloader

Resets the Switcher to the default routing state

Sets the IR address for the Switcher

Toggles the lock power state

Toggles Standby (power OFF) Mode

#ACTIVEBOLO Command

The #ACTIVEBOLO function activates the bootloader. This command is required in order to begin the fi rmware update procedure. See page 26 for details.

Syntax:

#activebolo

Parameters:

None

Notes:

This command must be executed twice, in order to active the bootloader.

20

RS-232 COMMANDS

#FADEFAULT Function

The #FADEFAULT function will reset the Switcher to the default routing settings.

Syntax:

#fadefault

Parameters:

None

#IRRMTADD Command

The #IRRMTADD sets the IR channel. The IR channel for the Switcher and the

IR Remote Control Unit must be the same.

Syntax:

#irrmtadd param1

Parameters: param1

1

2

3

Value

0

Meaning

IR channel 0

IR channel 1

IR channel 2

IR channel 3

21

RS-232 COMMANDS

#LOCKPOWER Command

The #LOCKPOWER enables/disables the power lock state. Enabling this feature will store the 5V status for each input prior to shutting the unit down.

This preserves the 5V state when the unit is restarted.

Syntax:

#lockpower param1

Parameters: param1

Value

0

1

Meaning

Disable Power Lock

Enable Power Lock

#STBYMODE Command

The #STBYMODE command toggles the Standby Mode state. When the

Switcher is powered OFF (not unplugged), then the unit is in Standby Mode.

Executing this command from Standby Mode will power ON the Switcher.

Syntax:

#stbymode param1

Parameters: param1

Value

0

1

Meaning

Normal Mode

Standby Mode

22

RS-232 COMMANDS

Routing Commands

The following command does not require the ‘#’ character. A carriage return must be added to the end of the command.

Command

R

Description

Routing command

R Command

The R command switches to the specifi ed input.

Syntax:

r param1

Parameters: param1

DisplayPort Input [1 - 4]

23

TELNET CONTROL

The Gefen 8x1 DPKVM Switcher supports Telnet for controlling the Switcher over a network. To access this feature, an IP address, subnet, gateway, and port numbers need to be set correctly. Consult the network administrator to obtain the proper IP address and settings for this product to properly communicate with the

Switcher over a network.

The Telnet control must be confi gured using RS-232 commands. Once properly confi gured, enter the IP address that was assigned to the Switcher using a terminal program or other Telnet client.

1. Connect the Switcher to a computer using RS-232.

2. Use a terminal emulation program (e.g. HyperTerminal, PuTTY, Indigo, etc.) to connect to the Switcher. See page 14 for information on RS-232 confi guration.

IMPORTANT: When using HyperTerminal under Windows XP,

the LF (line feed) character option must be enabled.

3. Apply power to the Switcher. Information similar to the following will be displayed in the terminal window:

===================================================

GEFEN

DISPLAY PORT 841

FW version: 1.3

=================================================== the command to display the current IP settings. The factory

(default) settings are displayed below:

#ipconfi g

------------------- TCP/IP settings ---------------

Web Server Port

Telnet Server Port

= 80

= 23

Telnet password on login is set to ON

Note that the Telnet password is set to ON. A user name and password can be set for additional security. This option can also be disabled. See page 20 for details.

24

TELNET CONTROL

the command to set the IP address for the Switcher. Check with a network administrator to obtain an available address, if necessary.

DHCP is not supported by this Switcher.

#sipadd 192.168.2.234

New IP set to: 192.168.2.234

After setting the IP address, power-cycle the Switcher for the changes to take effect.

IMPORTANT: All IP confi guration changes will require the

Switcher to be power-cycled.

6 Specify the IP of the Switcher in the Telnet client. In this example, the IP address is set to 192.168.2.234. Once connected to the Switcher, the Telnet client will display a screen similar to the following:

----------- Welcome to DP841 Telnet Server ----------

You are user number 1 of 3 allowed.

You will be disconnected after 10 minutes of inactivity.

Login: Admin

Password: Admin

Type Cmd:

By default, the user name and password options are enabled by use of the #use_telnet_pass command (see page 20). Once this command is enabled, the Switcher will prompt for both the user name and password.

The password cannot be disabled from the login process. Once logged in, the Type Cmd prompt will be displayed.

The Telnet interface uses the same commands and syntax that are used with

RS-232 control. See the command list, starting on page 15.

25

FIRMWARE UPDATE

Firmware Update Procedure

Any terminal emulation program can be used to perform the upgrade process. The instructions below is outlined for Windows® HyperTerminal.

1. Connect an RS-232 cable between the Switcher and the computer running the terminal program. Verify the correct serial port settings (see page 14).

the command then press the [ENTER] key.

3. Repeat Step 2.

The following will be displayed on the screen:

================== Main Menu ========================

Download new program -------- 1

Cancel ---------------------- 2

=====================================================

4. Press [1] on the computer keyboard to begin downloading program to the htemporary memory.

5. The following message will be displayed:

Waiting for the fi le to be sent ... (press ‘a’ to abort)

6. In Hyperterminal, click Transfer > Send File...

10. After a few moments, a message will appear in Hyperterminal:

Programming Completed Successfully!

26

RACK EAR INSTALLATION

Installing the Rack Ears

Rack mount ears are provided for installation of this unit into a 1U rack mount space.

1. Locate the side screws on the unit.

2. Remove the front 2 screws that are located closest to the front of the unit.

3. Using the removed screws, screw the rack mounting bracket into the unit.

4. Repeat the procedure on the opposite side of the unit.

Front of unit

Rear of unit

27

SPECIFICATIONS

Maximum Pixel Clock................................................................................360 MHz

Video Input Connectors.......................................................(8) DisplayPort, female

Video Output Connector......................................................(1) DisplayPort, female

USB Host Connectors..................................................(8) USB 2.0 Type B, female

USB Device Connectors...............................................(2) USB 2.0 Type A, female

Audio Input Connectors................................................(8) 3.5 mm mini-stereo jack

Audio Output Connector...............................................(1) 3.5 mm mini-stereo jack

IR Extender Connector.................................................(1) 3.5 mm mini-stereo jack

RS-232 Control Connector.............................................................(1) DB-9, female

Power Supply..................................................................................5V DC, Locking

Dimensions.......................................................... (W x H x D): 17.1” x 1.75” x 4.25

(434mm x 44mm x 108mm)

Shipping Weight...............................................................................12 lbs. (5.4 kg)

28

WARRANTY

Gefen warrants the equipment it manufactures to be free from defects in material and workmanship.

If equipment fails because of such defects and Gefen is notifi ed within two (2) years from the date of shipment, Gefen will, at its option, repair or replace the equipment, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifi cations. Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair. Such repairs are warranted for ninety (90) days from the day of reshipment to the Buyer.

This warranty is in lieu of all other warranties expressed or implied, including without limitation, any implied warranty or merchantability or fi tness for any particular purpose, all of which are expressly disclaimed.

1. Proof of sale may be required in order to claim warranty.

2. Customers outside the US are responsible for shipping charges to and from

Gefen.

3. Copper cables are limited to a 30 day warranty and cables must be in their original condition.

The information in this manual has been carefully checked and is believed to be accurate. However, Gefen assumes no responsibility for any inaccuracies that may be contained in this manual. In no event will Gefen be liable for direct, indirect, special, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. The technical information contained herein regarding the features and specifi cations is subject to change without notice.

For the latest warranty coverage information, refer to the Warranty and Return

Policy under the Support section of the Gefen Web site at www.gefen.com.

PRODUCT REGISTRATION

Please register your product online by visiting the Register Product page under the Support section of the Gefen Web site.

29

Rev A4

20600 Nordhoff St., Chatsworth CA 91311

1-800-545-6900 818-772-9100 fax: 818-772-9120 www.gefen.com [email protected]

Pb

This product uses UL listed power supplies.

advertisement

Related manuals

Frequently Answers and Questions

What are the possible IR channels for the device?
IR channels 0, 1, 2, and 3.
How many source devices can be connected to the switcher?
Up to eight DisplayPort source devices.
Does the device support DHCP?
No, the device does not support DHCP.
What is the default IR channel for the switcher and IR remote control unit?
Channel 0.
What are some methods for controlling the switcher?
Front-panel buttons, IR remote control, RS-232 port, Telnet, and IP control.
What type of power supply does the device use?
5V DC locking power supply.
How many USB outputs does the device have?
Two USB 2.0 ports.
What type of cables are included with the device?
Eight 6 ft. DisplayPort cables, eight 6 ft. USB 2.0 cables (A - B), and eight 6 ft. 3.5 mm mini-stereo audio cables.
What is the maximum resolution supported by the device?
2560 x 1600.
Does the device support HDCP content?
No, HDCP content is not supported.

advertisement