Gefen EXT-DP-841 Owner Manual


Add to my manuals
34 Pages

advertisement

Gefen EXT-DP-841 Owner Manual | Manualzz

®

ASKING FOR ASSISTANCE

Technical Support:

Telephone (818) 772-9100

545-6900

Fax

Technical Support Hours:

8:00 AM to 5:00 PM Monday thru Friday.

Write To:

Gefen LLC c/o Customer Service

20600 Nordhoff St

Chatsworth, CA 91311 www.gefen.com

[email protected]

Notice

Gefen, LLC reserves the right to make changes in the hardware, packaging, and any accompanying documentation without prior written notice.

8x1 DisplayPort Switcher is a trademark of Gefen, LLC

© 2015 Gefen, LLC. All rights reserved.

All trademarks are the property of their respective owners.

Rev A6

CONTENTS

1 Introduction

2 Operation Notes

3 Features

4 Front Panel Layout

5 Front Panel Descriptions

6 Back Panel Layout

7 Back Panel Descriptions

8 IR Remote Control Unit

8 Layout and Description

9 Installing the Battery

10 Configuring the IR Remote Control Unit

11 Connecting the 8x1 DisplayPort Switcher

11 Wiring Diagram

12 Operating the 8x1 DisplayPort Switcher

12 Front Panel Buttons and LED Indicators

12 Switching sources using the front-panel buttons

12 Switching sources using the IR Remote Control Unit

13 Switching sources using RS-232

13 Switching sources using Telnet

14 RS-232 Control

15 RS-232 Commands

15 IP Configuration

20 General Commands

23 Routing and Extender Commands

24 Telnet Control

26 Specifications

27 Warranty

28 Licensing

INTRODUCTION

Congratulations on your purchase of the 8x1 DisplayPort Switcher. Your complete satisfaction is very important to us.

Gefen

Gefen delivers innovative and progressive computer and electronics addon solutions that harness integration, extension, distribution, and conversion technologies. Gefen’s reliable plug-and-play products supplement cross-platform computer systems, professional audio/video environments, and HDTV systems of all sizes with hard-working solutions that are easy to install and simple to operate.

The Gefen 8x1 DisplayPort Switcher

Easily switch between eight DisplayPort computers with the Gefen 8x1

DisplayPort Switcher.

The Gefen 8x1 DisplayPort Switcher is a convenient, reliable and economical solution for using as many as eight DisplayPort equipped Mac or PC

computers with a single DisplayPort Monitor. The unit offers multiple options for control including front panel buttons, an included IR remote, rear panel IR and

RS-232 ports, and even an Ethernet port to accommodate IP control. Rack ears are included for installations where rack-mounting is desired.

The 8x1 DP Switcher is compatible with all operating systems using DisplayPort.

How It Works

Connect the eight included 6-foot DisplayPort cables between the computers and the Switcher inputs. Connect the Switcher output to the monitor using a

DisplayPort cable. Connect the included 5V DC locking power supply to the 8x1

Switcher and connect the AC power cord to an available electrical outlet.

The currently selected source will be displayed.

1

OPERATION NOTES

READ THESE NOTES BEFORE INSTALLING OR

OPERATING THE 8X1 DISPLAYPORT SWITCHER

• The 8x1 DisplayPort Switcher supports Pass-through EDID. The Switcher will use the EDID from the currently active input.

• Dual Link resolutions up to 2560 x 1600 are supported.

• HDCP content is not supported.

• This Switcher does not support DHCP.

• The default IR channel for both the Switcher and the IR Remote Control Unit is channel 0. See page 10 for more information.

2

FEATURES

Features

• Supports 1080p Full HD at 120Hz and dual-link resolutions up to 2560 x

1600 (WQXGA)

• Supports RGB and YCbCr color spaces

• Front-panel switching using discrete select buttons

• RS-232 port for automation

• IR remote control (included)

• External IR receiver jack

• Jack for external IR Receiver

• Saves space on your desktop

• Locking power supply

• Rack-mountable

Package Includes

(1) 8x1 DisplayPort Switcher

(1) IR Remote Control Unit

(8) DisplayPort Cables

(1) Set of Rack Ears

(1) 5V DC, Locking Power Supply

(1) AC Power Cord

(1) Quick-Start Guide

3

FRONT PANEL LAYOUT

4

FRONT PANEL DESCRIPTIONS

1 Input Indicators (1 - 8)

Each of these LED indicators glows bright blue according to the input selection

(see Input Buttons, below)

2 IR

Receives I/R signal from the included IR Remote Control Unit.

3 Input Buttons (1 - 8)

Pressing each of these buttons selects the desired input source (1 - 8).

4 Power

This LED indicator will glow bright red when the unit is powered.

5

BACK PANEL LAYOUT

6

BACK PANEL DESCRIPTIONS

1 5V DC

Connect the included 5V DC locking power supply to this receptacle.

2 In 1 - In 8

Each of these ports will accept a standard DisplayPort source device.

3 DP Out

This port will accept a single standard DisplayPort output device. The currently selected DisplayPort input source will be output via this port.

4 Ext IR

Connect an IR extender cable to this port.

5 RS-232 Serial Port

This port is used for serial communication using an RS-232 control device. For details, refer to page 14.

6 Ethernet

Connect the Switcher to a network in order to communicate via Telnet.

7

2

IR REMOTE CONTROL UNIT

Layout and Description

1

1 Activity Indicator

This LED will be activated momentarily each time a button is pressed.

2 Source Selection Buttons (1 - 8)

These buttons are used to select which source is routed to a monitor.

NOTE: An Activity Indictor that flashes quickly while holding down any one of the eight buttons indicates a low battery. Replace the

IR Remote Control battery as soon as possible.

8

IR REMOTE CONTROL UNIT

Installing the RMT-8IR Battery

1. Remove the battery cover on the back of the IR Remote Control Unit.

2. Insert the included battery into the open battery slot. The positive (+) side of the battery should be facing up.

3. Replace the battery cover.

The Remote Control unit ships with two batteries. One battery is required for operation and the other battery is a spare.

Battery Slot

WARNING: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.

9

IR REMOTE CONTROL UNIT

How to Resolve IR Code Conflicts

In the event that IR commands from other remote controls interfere with the supplied IR Remote Control unit, changing the IR Remote Control’s IR channel will fix the problem. The IR Remote Control unit has a bank of DIP switches used for setting the IR channel. The DIP switch bank is located underneath the battery cover.

Left: Picture of the opened rear battery compartment of the IR remote showing the exposed DIP Switch bank between the battery chambers.

Corresponding DIP Switch Settings for each IR Channel

IR Channel 0

(default)

ON

IR Channel 1

ON

IR Channel 2

ON

IR Channel 3

ON

1 2 1 2 1 2

It is important that the IR channel on the Remote Control unit, matches the IR channel set on the 8x1 DisplayPort Switcher. For example, if both DIP switches on the IR Remote Control unit are set to IR channel 0 (both DIP switches down), then the 8x1 DisplayPort Switcher must also be set to IR channel 0. See page

21 on how to change the IR channel on the 8x1 DisplayPort Switcher.

10

CONNECTING THE 8X1 DISPLAYPORT SWITCHER

How to Connect the 8x1 DisplayPort Switcher

1 Connect up to eight (8) DisplayPort source devices to the DisplayPort inputs on the back panel of the Switcher using DisplayPort cables.

2 Connect a DisplayPort-supported display to the DisplayPort output on the back panel of the Switcher.

a OPTIONAL: To use the RS-232 communication feature, connect an

RS-232 cable between the Switcher and RS-232 host controller.

b OPTIONAL: To communicate with the Switcher using Telnet, connect an Ethernet cable from the Ethernet jack on the back of the Switcher to the network. See page 24 for more information on using the Telnet feature.

c OPTIONAL: To extend the range of the IR control, connect an IR

Extender (Gefen part no. EXT-RMT-EXTIR) to the back of the Switcher.

3 Connect the included 5V locking power supply to the power receptacle on the 8x1 DisplayPort Switcher

4 Connect the opposite end of the power supply to an open wall socket power source.

Wiring Diagram for the 8x1 DisplayPort Switcher

Computer

Computer

Computer

Computer

DISPLAYPORT CABLE

RS-232 CABLE

ETHERNET

IR

Computer

Computer

Computer

Computer

IR Extender

DisplayPort Switcher

DisplayPort Display

RS-232 Controller

Router

EXT-DP-841

ATTENTION: This product should always be connected to a grounded electrical socket.

11

OPERATING THE 8X1 DISPLAYPORT SWITCHER

Front Panel Buttons and LED Indicators

The front panel of the 8x1 DisplayPort Switcher has a set of eight (8) LED indicators, displaying which input (source) is being displayed. Each of these

LED indicators corresponds to one of the push-buttons on the front panel.

Switching sources using the front-panel buttons

Example: Switch to input 2 using the front-panel buttons:

1 Press button 2 on the front panel of the 8x1 DisplayPort Switcher.

2 The LED indicator for Input 2 will glow bright blue on the front panel.

1 2

Switching sources using the IR Remote Control

Example: Switch to Input 3 using the IR Remote Control:

1 Press button 3 on the IR Remote Control Unit. The Activity Indicator on the IR Remote Control Unit will glow yellow, indicating that a button was pressed.

2 The LED indicator for Input 3 will glow bright blue.

1 2

12

OPERATING THE 8X1 DISPLAYPORT SWITCHER

Switching sources using RS-232

Configure the Switch for use with RS-232 (see page 14 for details).

Example: Switch to input 5 using RS-232

1 Use the command r 5 to route the Switcher to Input 5. See page 14 - 15 for important information on RS-232 commands. RS-232 commands are case-sensitive.

2 The LED indicator for Input 5 will glow bright blue on the front panel.

1 2 terminal ready... r 5

Route to Input 5

Switching sources using Telnet

Configure the Switch for use with Telnet. See page 24 for details.

Example: Switch to Input 8 using the Telnet protocol

1 Use the command r 8 to route the Switcher to Input 8.

2 The LED indicator for Input 8 will glow bright blue.

1 2

Type Cmd: r 8

Route to Input 8

13

RS-232 CONTROL

Only pins 2 (Receive), 3 (Transmit), and 5 (Ground) are used for communication.

A null-modem adapter should not be used with this product.

5 4 3 2 1 1 2 3 4 5

9 8 7 6 6 7 8 9

Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface

Serial Port Settings

Bits per second ............................................................................................ 19200

Data bits ............................................................................................................... 8

Parity ............................................................................................................. None

Stop bits ................................................................................................................1

Flow Control .................................................................................................. None

NOTE: Only pins 2 (Receive), 3 (Transmit), and 5 (Ground) are used for communication. A null-modem adapter should not be used with this product.

14

RS-232 COMMANDS

Command Syntax

All RS-232 commands are case-sensitive and must be entered in lowercase.

Each command must be preceded by the ‘#’ character. A carriage return must also be appended to every command.

Example:

#set_http_port 80[CR]

IP Configuration

Command

#get_pass

#get_user_name

#ipconfig

#rstip

#set_http_port

#set_pass

#set_telnet_port

#set_user_name

#sgateway

#sipadd

#snetmask

#use_telnet_pass

Description

Prompts for the Telnet password

Prompts for the Telnet username

Displays all TCP/IP settings

Sets IP configuration to default settings

Sets the Web server listening port

Sets the Telnet password

Sets the Telnet listening port

Sets the Telnet user name

Specifies the new gateway

Specifies a new IP address

Specifies a new net mask

Toggles Telnet password prompt

#GET_PASS Command

The #GET_PASS command prompts for the Telnet password.

Syntax:

#get_pass

Parameters:

None

15

RS-232 COMMANDS

#GET_USER_NAME Command

The #GET_USER_NAME command prompts for the Telnet username.

Syntax:

#get_user_name

Parameters:

None

#IPCONFIG Command

The #IPCONFIG command displays all TCP/IP settings.

Syntax:

#ipconfig

Parameters:

None

#RSTIP Command

The #RSTIP command resets the IP configuration to the default settings.

Syntax:

#rstip

Parameters:

None

16

RS-232 COMMANDS

#SET_HTTP_PORT Command

The #SET_HTTP_PORT command sets the Web server listening port.

Syntax:

#set_http_port param1

Parameters: param1 Port [0 - 255]

#SET_PASS Command

The #SET_PASS command sets Telnet password.

Syntax:

#set_pass param1

Parameters: param1 String

Notes:

The maximum length of the password string is 20 characters.

#SET_TELNET_PORT Command

The #SET_TELNET_PORT command sets the Telnet server listening port.

Syntax:

#set_telnet_port param1

Parameters: param1 Port [0 - 255]

17

RS-232 COMMANDS

#SET_USER_NAME Command

The #SET_USER_NAME command sets the Telnet user name.

Syntax:

#set_user_name param1

Parameters: param1 String

Notes:

The maximum length of the username string is 20 characters.

#SGATEWAY Command

Specifies the new IP gateway. Dot-decimal notation must be used when specifying the IP address. A reboot is required after the new IP gateway address has been assigned.

Syntax:

#sgateway param1.param2.param3.param4

Parameters:

Example:

#sgateway 192.168.1.1

18

RS-232 COMMANDS

#SIPADD Command

The #SIPADD command specifies a new IP address. Dot-decimal notation must be used when specifying the IP address. A reboot is required after the new IP address is set.

Syntax:

#sipadd param1.param2.param3.param4

Parameters: param2 IP address [0 - 255]

Example:

#sipadd 192.168.2.240

#SNETMASK Command

The #SNETMASK command specifies a new net mask. Dot-decimal notation must be used when specifying the IP address. A reboot is required after the new

IP address is set.

Syntax:

#snetmask param1.param2.param3.param4

Parameters: param2 IP address [0 - 255]

Example:

#snetmask 255.255.255.0

19

RS-232 COMMANDS

#USE_TELNET_PASS Command

The #USE_TELNET_PASS command enables / disabled the use of a Telnet password during the login process.

Syntax:

#use_telnet_pass param1

Parameters: param1 State

Value

0

1

[0 - 1]

Meaning

Disable password

Enable password

General Commands

Command

#activebolo

#fadefault

#irrmtadd

#lockpower

#stbymode

Description

Activates the bootloader

Resets the Switcher to the default routing state

Sets the IR address for the Switcher

Toggles the lock power state

Toggles Standby (power OFF) Mode

#ACTIVEBOLO Command

The #ACTIVEBOLO function activates the bootloader. This command is required to be executed in order begin the firmware update procedure.

Syntax:

#activebolo

Parameters:

None

Notes:

This command must be executed twice, in order to active the bootloader.

20

RS-232 COMMANDS

#FADEFAULT Function

The #FADEFAULT function will reset the Switcher to the default routing settings.

Syntax:

#fadefault

Parameters:

None

#IRRMTADD Command

The #IRRMTADD sets the IR channel. The IR channel for the Switcher and the

IR Remote Control Unit must be the same.

Syntax:

#irrmtadd param1

Parameters: param1 State [0 - 3]

2

3

Value

0

1

Meaning

IR channel 0

IR channel 1

IR channel 2

IR channel 3

21

RS-232 COMMANDS

#LOCKPOWER Command

The #LOCKPOWER enables/disables the power lock state. Enabling this feature will store the 5V status for each input prior to shutting the unit down.

This preserves the 5V state when the unit is restarted.

Syntax:

#lockpower param1

Parameters: param1 State

Value

0

1

[0 - 1]

Meaning

Disable Power Lock

Enable Power Lock

#STBYMODE Command

The #STBYMODE command toggles the Standby Mode state. When the

Switcher is powered OFF (not unplugged), then the unit is in Standby Mode.

Executing this command from Standby Mode will power ON the Switcher.

Syntax:

#stbymode param1

Parameters: param1 Mode

Value

0

1

[0 - 1]

Meaning

Normal Mode

Standby Mode

22

RS-232 COMMANDS

Routing and Extender Commands

The following commands do not require the ‘#’ character. A carriage return must be added to the end of each command.

Command

R

Description

Routing command

R Command

The R command switches to the specified input.

Syntax: r param1

Parameters: param1 DisplayPort Input [1 - 8]

23

TELNET CONTROL

The Gefen 8x1 DisplayPort Switcher supports Telnet for controlling the Switcher over a network. To access this feature, an IP address, subnet, gateway, and port numbers need to be set correctly. Consult the network administrator to obtain the proper IP address and settings for this product to properly communicate with the

Switcher over a network.

The Telnet control must be configured using RS-232 commands. Once properly configured, enter the IP address that was assigned to the Switcher using a terminal program or other Telnet client.

1. Connect the Switcher to a computer using RS-232.

2. Use a terminal emulation program (e.g. HyperTerminal, PuTTY, Indigo, etc.) to connect to the Switcher. See page 14 for information on RS-232 configuration.

IMPORTANT: When using HyperTerminal under Windows XP, the LF (line feed) character option must be enabled.

3. Apply power to the Switcher. Information similar to the following will be displayed in the terminal window:

===================================================

GEFEN

DISPLAY PORT 841

FW version: 1.3

===================================================

4. Use the #ipconfig command to display the current IP settings. The factory

(default) settings are displayed below:

#ipconfig

------------------- TCP/IP settings ---------------

MAC addr

IP addr

Net Mask

= 00:1C:91:02:40:00

= 192.168.0.70

Gateway

= 255.255.255.0

=

Web Server Port

Telnet Server Port

192.168.0.1

= 80

= 23

Telnet password on login is set to ON

Note that the Telnet password is set to ON. A user name and password can be set for additional security. This option can also be disabled. See page 20 for details.

24

TELNET CONTROL

5. Use the #sipadd command to set the IP address for the Control System.

Check with a network administrator to obtain an available address, if necessary. DHCP is not supported by this Switcher.

#sipadd 192.168.2.234

New IP set to: 192.168.2.234

After setting the IP address, power-cycle the Switcher for the changes to take effect.

IMPORTANT: All IP configuration changes will require the

Switcher to be power-cycled.

6 Specify the IP of the Control System in the Telnet client. In this example, the

IP address is set to 192.168.2.234. Once connected to the Control System, the Telnet client will display a screen similar to the following:

----------- Welcome to DP841 Telnet Server ----------

You are user number 1 of 3 allowed.

You will be disconnected after 10 minutes of inactivity.

Login: Admin

Password: Admin

Type Cmd:

By default, the user name and password options are enabled by use of the #use_telnet_pass command (see page 20). Once this command is enabled, the Switcher will prompt for both the user name and password.

The password cannot be disabled from the login process. Once logged in, the Type Cmd prompt will be displayed.

The Telnet interface uses the same commands and syntax that are used with

RS-232 control. See the command list, starting on page 15.

25

SPECIFICATIONS

Maximum Pixel Clock................................................................................360 MHz

Video Input Connectors.......................................................(8) DisplayPort, female

Output Connector................................................................(1) DisplayPort, female

IR Extender Connector..................................................(1) 3.5mm mini-stereo jack

RS-232 Port...................................................................................(1) DB-9, female

Power Supply..................................................................................5V DC, Locking

Power Consumption.............................................................................. 10W (max)

Rack Size.................................................................................(rack ears included)

Dimensions (W x H x D).......................................................... 17.1” x 1.75” x 4.25”

(434mm x 44mm x 108mm)

Shipping Weight...............................................................................12 lbs. (5.4 kg)

26

WARRANTY

Gefen warrants the equipment it manufactures to be free from defects in material and workmanship.

If equipment fails because of such defects and Gefen is notified within two (2) years from the date of shipment, Gefen will, at its option, repair or replace the equipment, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifications. Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair. Such repairs are warranted for ninety (90) days from the day of reshipment to the Buyer.

This warranty is in lieu of all other warranties expressed or implied, including without limitation, any implied warranty or merchantability or fitness for any particular purpose, all of which are expressly disclaimed.

1. Proof of sale may be required in order to claim warranty.

2. Customers outside the US are responsible for shipping charges to and from

Gefen.

3. Copper cables are limited to a 30 day warranty and cables must be in their original condition.

The information in this manual has been carefully checked and is believed to be accurate. However, Gefen assumes no responsibility for any inaccuracies that may be contained in this manual. In no event will Gefen be liable for direct, indirect, special, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. The technical information contained herein regarding the features and specifications is subject to change without notice.

For the latest warranty coverage information, refer to the Warranty and Return

Policy under the Support section of the Gefen Web site at www.gefen.com.

PRODUCT REGISTRATION

Please register your product online by visiting the Register Product page under the Support section of the Gefen Web site.

27

LICENSING

This product uses software that is subject to open source licenses, including one or more of the General Public License Version 2 and Version 2.1, Lesser General Public License

Version 2.1 and Version 3, BSD, and BSD-style licenses. Distribution and use of this product is subject to the license terms and limitations of liability provided in those licenses.

Specific license terms and Copyright Notifications are provided in the source code.

For three years from date of activation of this product, any party may request, and we will supply, for software covered by an applicable license (e.g. GPL or LGPL), a complete machine-readable copy of the corresponding open source code on a medium customarily used for software interchange. The following software and libraries are included with this product and subject to their respective open source licenses:

• lwIP

• freeRTOS

• jQuery lwIP is licenced under the BSD licence:

Copyright (c) 2001-2004 Swedish Institute of Computer Science.

All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.

2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.

3. The name of the author may not be used to endorse or promote products derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS’’ AND ANY EXPRESS

OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE

ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT,

INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES

(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR

SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)

HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN

CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR

OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF

ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

28

Rev A6

20600 Nordhoff St., Chatsworth CA 91311

1-800-545-6900 818-772-9100 fax: 818-772-9120 www.gefen.com [email protected]

Pb

This product uses UL listed power supplies.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement