User's Guide
Document Number: 012-14016A
User's Guide
PASCO Capstone User's Guide
Document Number: 012-14016A
Limited Warranty
For a description of the product warranty, see the PASCO scientific catalog.
Copyright
This User's Guide is copyrighted with all rights reserved. Permission is granted to nonprofit educational institutions for reproduction of any part of this manual, providing the reproductions are used only in their laboratories and classrooms, and are not sold for profit. Reproduction under any other circumstances, without the written consent of PASCO scientific, is prohibited.
Trademarks
PASCO, PASCO scientific, PASCO Capstone, DataStudio, PASPORT, SPARK,
SPARK Science Learning System, SPARKlab, SPARKbook, SPARKvue, SPARKvue
HD, Xplorer, Xplorer GLX are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify products or services of their respective owners. For more information visit www.pasco.com/legal.
Software Licenses
All required licenses for software components of Capstone can be found on the Flash
Drive, CD-ROM, or DVD-ROM included with the product or are included in the software download. To obtain source code for GPL/LGPL licensed software components, contact PASCO scientific by phone: 1-800-772-8700 (in the U.S), +1 916 786 3800
(worldwide), or by email: [email protected]
012-14016A i
User's Guide
Teacher and Technical Support
For questions about PASCO Capstone and other PASCO scientific products that are not answered in the Help or User's Guide, you can contact the PASCO Teacher and Technical Support staff by phone, email, or on the Web.
Phone:
Email:
Web:
Tech Notes:
1-800-772-8700 (in the U.S.)
+1 916 786 3800 (worldwide) [email protected]
www.pasco.com/support/ www.pasco.com/support/technical-support/technote/
See "Where can I find help documentation and curriculum for PASCO Capstone?":
012-14016A ii
User's Guide
Contents
Connecting an 850 Universal or 750 USB Interface
Connecting Bluetooth Interfaces: such as the SPARKlink Air or AirLink2
Connecting a 750 SCSI or 500 serial Interface
Connecting USB PASPORT Interfaces: such as the SPARK SLS,
Connecting an Xplorer GLX or Xplorer
Connecting a sensor with the 850 Interface
Connecting a sensor with the 750 Interface
Connecting a sensor with the SPARK SLS, SPARKlink, SPARKlink Air
Connecting a sensor with the Xplorer GLX
Connecting a sensor with the Digital Adapter or Photogate Port
Connecting a sensor with the Analog Adapter
012-14016A iii
User's Guide
Connecting a sensor with the AirLink2
Downloading Capstone experiments
How do I... Installation and Update
How do I automate a network installation?
How do I force an update to an interface?
How do I download and open PASCO ready-made experiments?
How do I open DataStudio experiments and data?
How do I open Xplorer GLX, SPARK SLS, and other non-Capstone experiments and data?
How do I import data from Microsoft Excel*?
How do I export data to Microsoft Excel*?
How do I import Xplorer GLX data?
How do I... Data and Measurements
How do I record data in PASCO Capstone?
How do I choose one or more runs to display?
How do I identify a measurement when I have multiple of the same type?
How do I change the numerical format of data?
How do I change the numerical format of statistics?
How do I exclude, delete, and restore selected data?
How do I create a pure mathematical function?
012-14016A iv
User's Guide
How do I show, hide, and lock the palettes?
How do I change what display toolbar buttons are visible?
How do I switch the sign on a sensor?
How do I calibrate a motion sensor?
How do I calibrate a drop counter?
How do I calibrate a pH sensor?
How do I create a calculation?
How do I select a measurement in the calculator?
How do I see the result of a calculation?
How do I reorder calculations?
How do I plot multiple measurements on separate plot areas with shared Xaxis?
How do I plot multiple measurements on same plot with multiple Y-axes?
How do I plot multiple measurements on same plot with same Y-axes?
How do I apply a curve fit to a portion of the data?
How do I change curve fit parameters?
How do I adjust the weights for the weighted linear fit?
How do I lock and unlock the axes of a graph?
012-14016A v
User's Guide
How do I change layer order of a display?
How do I reorder columns in a table?
How do I use a table to build data in Keep Mode?
How do I enter subscripts, superscripts, Greek letters, and symbols?
How do I enter an equation into a text display?
How do I compare scope traces from the same sensor when monitoring?
How do I select the scope trigger?
How do I freeze and record the scope display?
How do I manually synchronize video with data?
How do I adjust the frame rate of a recorded video?
How do I adjust the resolution of a video?
How do I make files with videos smaller?
How do I troubleshot video problems?
4 Frequently Asked Questions (FAQ)
Where can I find help documentation and curriculum for PASCO Capstone? 147
What are the new features in the latest PASCO Capstone?
151 Can PASCO Capstone open DataStudio, SPARKlab, and GLX files?
Can Capstone files be opened on computers with different operating systems?
012-14016A vi
How does Capstone compare to other PASCO applications?
FAQ... Installation and Updates
Is an MSI available for PASCO Capstone?
Do I need to update the interfaces?
Do I need to update the sensor datasheets?
What do I need to have a complete measurement system?
Can sensors sample at different rates?
What is the file export format?
What is the format for text import?
Can sensors sample at different rates?
Is there a way to delete data points?
How are the curve fit and smoothing calculations determined?
FAQ... Calculations and Calibration
What is the format for calculations?
What are the equations for calibration?
Can multiple measurements be calibrated simultaneously?
User's Guide
012-14016A vii
Why are the display toolbars not active?
What does the Single Shot button do?
What is pre-triggering in the scope?
What cameras and video formats are supported?
Why does the text color remain black after picking a color?
User's Guide
012-14016A viii
1 Tour the Interface
1 Tour the Interface
Click to learn more
Online Videos
012-14016A 1
Tour the Menu and Toolbar
1 Tour the Interface
Tour the Menu and Toolbar
The Capstone menu includes common application functions and application specific functions. Some functions are available as toolbar buttons.
Descriptions for Capstone Menu and Toolbar functions: Tip
1
File
Menu item
Import Data...
Export Data...
Preferences
Description
Import data into the Capstone data summary.
Export collect data to a text file.
Set global preferences including: l l l l l l l
Preference File
General Application
Language
Workbook
Displays Palette
Tools Palette
Controls Palette
Edit
Icon Menu item
Undo
Redo
Cut
Copy
Paste
Description
Undo the last operation.
Tip
2
Redo an Undo operation Tip
2
Cut the selected display element
Copy the selected display element
Paste a Cut or Copied display element
1
Capstone includes descriptions within dialog boxes. Click on an item for a brief description.
2
2
The operation that will be undone is listed in the menu.
The operation that will be re-done is listed in the menu.
012-14016A 2
1 Tour the Interface
Tour the Menu and Toolbar
Workbook
Icon Menu item
Add Page
Delete Page
Rename Page
Lock All Pages
Unlock All Pages
Edit Master Page
Workbook Page Properties
Description
Add Page To Workbook
Delete this Page
Rename Current Workbook Page
Lock all current pages for editing. Pages can still be added and will not be locked; to lock added pages, click Lock All Pages.
Unlock pages to allow editing.
Opens the Master Page Add text and graphics to appear in the background of other pages.
Set workbook preferences, including: l l l l l l
Page Name
Snap to Grid
Show Tools Palette
Show Displays Palette
Show Controls Palette
Page Shape
Display
Icon Menu item
Display
Description
Shows tools that apply to the selected display.
012-14016A 3
1 Tour the Interface
Tour the Menu and Toolbar
Journal
Icon Menu item Description
Takes an image and places it in the journal. Select:
Take Journal snapshot |
Select snapshot mode
Snapshot Entire Workbook Page
Snapshot Workbook Page Content
Snapshot Workbook Page Display
Lists the journal snapshots and allows:
Show or hide Journal
Show or hide annotations
Print Journal
Export Journal to HTML
View full-size snapshot
Delete selected snapshot
Move selected snapshot up
Move selected snapshot down
Help
Icon Menu item Description
Opens the Capstone Help System in a separate browser. A PDF version of the User's Guide is also available from the Help System.
PASCO Capstone Help
See "Where can I find help documentation and curriculum for PASCO Capstone?": 147
About PASCO Capstone
Opens a dialog with version information and the ability enter a license key.
Delete Display
Icon Menu item
Delete Selected Display
Description
Deletes the active display on the workbook page.
Data are not affected.
012-14016A 4
1 Tour the Interface
Tour the Page Tools
Tour the Page Tools
See "How do I... Workbooks": 89 .
Edit Master Page
Icon Description
Master Page Add text and graphics to appear in the background of other pages.
Properties
Icon Description
Change properties of current page and Tools Palette
Add Page
Icon Description
Adds a new page to the workbook
Drag and drop page tabs to rearrange the workbook pages.
See
.
Rename / Delete
Icon Description
Double click to rename the page.
Deletes the current page from the workbook.
012-14016A 5
1 Tour the Interface
Tour the Tools Palette
Tour the Tools Palette
Hardware Setup
Icon Description
Configure interface and sensor hardware
See
"Connecting an interface": 17 .
Timer Setup
Icon Description
Create timers for photogates and other timing devices
Data Summary
Icon Description
Manage experiment data and data properties
See
"How do I... Data and Measurements": 73
.
Calibration
Icon Description
Calibrate sensor measurements
See
.
Calculator
Icon Description
Define new data sets as functions of measurements and other data
See
"How do I... Calculations": 99 .
Signal Generator
Icon Description
Control interface Signal Generator output
Digital Output
Icon Description
Specify behavior for expansion port inputs and/or outputs
012-14016A 6
1 Tour the Interface
Tour the Tools Palette
Curve Fit Editor
Icon Description
Edit curve fits created in Graph displays
See
"How do I change curve fit parameters?": 118 .
012-14016A 7
1 Tour the Interface
Tour the Controls Palette
Tour the Controls Palette
The Controls Palette is used to start/stop data collection, set the data monitoring mode, set the sampling rate,delete data runs, and define Start/Stop conditions.
Record / Play Selection
Icon Description
Toggle between:
Recording Mode
Playback Mode
Use to switch to recording Controls Palette
Use to switch to playback Controls Palette
Record / Monitor
Icon Description
Capstone toggles between:
Record Begin recording all measurements from each connected sensor
Monitor Start monitoring measurements from connected sensors
Record Mode Selection
Icon Description
Toggle between:
Continuous
Mode
Set to record data at the current sample rate settings
Keep Mode Set to keep data points when commanded
Fast Monitor
Mode
Set to acquire data without recording; required for high speed sampling in Scope and FFT displays
See
"How do I record data in PASCO Capstone? ": 73
012-14016A 8
1 Tour the Interface
Tour the Controls Palette
Record Timer
Description
Displays the recording time as reported by the sensors in
minutes:seconds format.
Displays the recording status: Ready or Recording
Sampling Source and Sample Rate
Description
Sampling rate source: single sensor or Common Rate
Note: Common Rate is applied to all sensors. The Sample
Rate range for Common Rate is intersection of all sensor ranges.
Adjust the Sample Rate
Start / Stop Conditions
Icon Description
Set automatic Start/Stop conditions
Delete Runs
Icon Description
Delete most recent run
Delete All Runs or a specific run
012-14016A 9
1 Tour the Interface
Tour the Displays Palette
Tour the Displays Palette
Drag to page or double-click to create a display ( See "Adding a display ":
Graph
Icon Description
Create a line graph to plot captured data or user defined data.
Several tools are available for graphs including statistics, curve fit, slope tool, and smoothing.
.
Scope
Icon Description
Create a display that functions as a digital storage oscilloscope, which is useful for viewing measurements that oscillate rapidly in time.
FFT
Icon Description
Create a spectral analysis display, which uses a Fast Fourier
Transform to measure the relative signal intensity as a function of frequency.
Histogram
Icon Description
Create a histogram bar graph. The height of each of the bars is proportional to the number of data that fall within the range of values that the bar represents. Several tools are available for histograms including statistics, setting bin sizes, and overlaying.
Digits
012-14016A 10
1 Tour the Interface
Tour the Displays Palette
Icon Description
Create a digits display to show the current data value or a statistical value.
Meter
Icon Description
Create a meter display to indicate the current data value (or statistical value) by the angular displacement of a needle against a dial indicator. Several meter styles are available.
Table
Icon Description
Create a table to list captured data or user defined data in columns.
Note: Tables are used to enter user-defined numerical or text data. Several tools are available for tables including statistics
.
Text Box
Icon Description
Create a text box for explanatory text and images. The text box can be locked for editing.
Tip
1
See "How do I... Text Boxes": 127 .
Text Entry Box
Icon Description
Create a text entry box for user input. The input can be linked to other text entry boxes.
Tip
1
See "How do I... Text Boxes": 127 .
Image
Icon Description
Create a box to insert an image from a file. Note: Use the Movie icon to capture an image from an attached USB camera.)
1
Use a Text Entry Box for user student input on a locked experiment.
1
Use the linkage to present a previously entered student response on a subsequent page of the Workbook. For example, to combine all the answers on a single page.
012-14016A 11
1 Tour the Interface
Tour the Displays Palette
Movie
Icon Description
Create a box to insert a movie file, capture an image from a video camera or microscope connected through a USB port, record a stand-alone video using a USB webcam, or use a USB video camera as a sensor to record a movie along with other sensor data.
A special video analysis mode accessed from the toolbar provides tools for analyzing videos and image snapshots.
.
Placeholder
Icon Description
Create a spacer for a display to be defined at a later time or create white space.
012-14016A 12
1 Tour the Interface
Tour the Display Area
Tour the Display Area
The PASCO Capstone Workbook pages facilitate quick and easy layouts and support highly flexible page designs.
Features
Drag and drop targets
Easy resize and alignment tools
QuickStart templates
See
QuickStart Templates
Easy table creation, including calculated data
Text boxes with equations copied from word processor
"How do I... Calculations": 99
012-14016A 13
1 Tour the Interface
Tour Context Help
Tour Context Help
Some items in PASCO Capstone include helpful information at the bottom of dialog windows. To see the help: Click on an item for a brief description.
Context Help Example: File Properties dialog
Click on an item for a brief description.
Information displays here.
012-14016A 14
1 Tour the Interface
Tour the Scope
Tour the Scope
Overview
The scope is designed to view high-frequency oscillating data or single high-speed events that the graph display may not be able to capture.
Maximum Sampling Rate: The maximum supported sampling rate is a function of the computer-sensor interface that is connected to the computer (for example: 850 Universal
Interface → 10 MHz, ScienceWorkshop 750 → 250 kHz).
Features
Continuous Mode and Fast Monitor
Mode
Single shot
Multiple triggers
Pre-trigger
Image freeze
See
"What is Continuous Mode?": 168
"What is Fast Monitor Mode?": 169
"What does the Single Shot button do?": 178
"How do I select the scope trigger?": 131
"How do I freeze and record the scope display?": 135
Toolbar
Icon Description
Adjust y-axis scale to fit data
Activate and control scope trigger
Stop collection after one trace
Automatically adjust sample rate based on time-axis scale
Activate to view multiple runs; Select visible run(s)
Increase trace offset
Set trace offset value to zero
Decrease trace offset
Show data coordinates and access Delta Tool
Creates a data set from active traces
Increase number of data points in trace
Decrease number of data points in trace
Add new y-axis to scope display
Remove active element or axis
Allow rearrangement of axes
Pin toolbar to display
012-14016A 15
Properties
Show or hide tools
See
1 Tour the Interface
Tour the Scope
012-14016A 16
2 Getting Started
Connecting an interface
2 Getting Started
See the following topics setting up and run a simple experiment:
"Downloading Capstone experiments": 61
for detailed instructions.
Connecting an interface
Capstone software running on your computer receives data from one or more connected sensors through one or more interfaces. (At least one interface and sensor is required to collect data. (
See "What do I need to have a complete measurement system? ": 162
)
Capstone is compatible with all PASCO USB interfaces and some non-USB interfaces using a serial-to-USB convertor.
Tip
1
Automatically detect an interface
1. Connect one or more PASCO USB interfaces to the computer.
Tip
2
"Connecting an 850 Universal or 750 USB Interface":
"Connecting a 750 SCSI or 500 serial Interface": 24
"Connecting Bluetooth Interfaces: such as the
SPARKlink Air or AirLink2": 22
"Connecting USB PASPORT Interfaces: such as the
SPARK SLS, SPARKlink, or Power Link": 25
"Connecting an Xplorer GLX or Xplorer": 26
2. Add one or sensors. ( See
1
You can add interfaces that are not connected to the computer. This is useful to author or prepare experiments in advance.
2
Interfaces can be connected to your computer with Capstone running. Capstone will automatically add recognized interfaces such as the 850 Universal Interface.
012-14016A 17
Manually add an interface
1. Click Hardware Setup in the Tools Palette: .
Hardware Setup button
2 Getting Started
Connecting an interface
2. Add the interface if not displayed in the Hardware Setup list.
Tip
1
3. If the interface is not automatically detected, click the Choose Interface button.
4. The Choose Interface dialog opens.
1
Some PASCO interfaces, such as the PASCO 850 and SPARK, are automatically detected by Capstone when plugged in and turned on.
012-14016A 18
Choose Interface
2 Getting Started
Connecting an interface
Click Manually Choose.
Click the interfaces to add or remove.
Optional: change the default of 1 interface to add multiple interfaces of the same type.
012-14016A 19
2 Getting Started
Connecting an interface
Active interface indicator
Inactive interface indicator
5. Add one or sensors. ( See
Connected and added interfaces are displayed in the Hardware Setup dialog.
Note: Interfaces that are connected to the computer, powered on, and recognized by Capstone display ( ) and interfaces that are not active display ( ).
012-14016A 20
2 Getting Started
Connecting an interface
Active and inactive interfaces and sensors in Hardware Setup
Active interface
Inactive interface (disconnected or off )
Active sensor
Inactive sensor (disconnected or off )
Next step:
Connecting an 850 Universal or 750 USB Interface
The PASCO 850 Universal Interface includes four digital inputs, four analog ports, four PASPORT sensor ports, a 15 W function generator, dual high speed function generators.
Procedure
1. Use the A-to-mini-B USB cable to connect the smaller USB port of the 850 Interface to a USB port on your computer (or a USB hub connected to the computer).
2. Connect the AC adapter to a wall outlet and to the AC adapter port on the rear of the 850 Universal Interface.
012-14016A 21
2 Getting Started
Connecting an interface
850 Universal Interface: USB and Power
AC adapter port
USB connector
3. Press and hold the power button ( ) until the green lights on the front flash.
850 Universal Interface: On button
4. Configure the interface for Capstone. ( See
)
5. Add sensors. (See
"Connecting a sensor with the 850 Interface": 36 )
Next step:
Connecting Bluetooth Interfaces: such as the SPARKlink Air or
AirLink2
SPARKlink Air is a sensor interface with two ports to accept PASPORT sensors and ports for the included Voltage Probe and Temperature Probe.
The SPARKlink Air interface connects to a computer or tablet device wirelessly via
Bluetooth (radio), or can also connect to a computer’s USB port with the included USB cable. The SPARKlink Air operates on battery power or can be connected to the included AC adapter. The SPARKlink Air battery can also be recharged using the USB cable connected to a USB port.
Procedure
1. Optional: Connect the AC adapter (included with the SPARKlink Air) to a wall outlet and to the AC adapter port on the bottom of the device.
012-14016A 22
2 Getting Started
Connecting an interface
The Battery Status LED may blink red to indicate that the battery is charging through the power cable.
SPARKlink USB and power
AC adapter port
Power button
USB port
2. Connect the SPARKlink Air to the computer via bluetooth or USB.
Pairing bluetooth i. Press and hold the ON/OFF button on the SPARKlink Air.
ii. After the status LEDs blink in sequence, release the ON/OFF button.
The Bluetooth status LED will blink blue.
iii. Enable the Windows or Macintosh computer for Bluetooth communication.
USB connection i. Use an A-to-mini-B USB cable (such as PASCO part PS-2528) to connect the smaller USB port of the SPARK to a USB port on your computer (or a
USB hub connected to the computer).
ii. Press and hold the ON/OFF button on the SPARKlink Air.
iii. After the status LEDs blink in sequence, release the ON/OFF button.
The USB Status LED will shine green. The Battery Status LED may blink red to indicate that the battery is charging through the USB.
012-14016A 23
2 Getting Started
Connecting an interface
LED status definitions
Bluetooth status
USB
Status
Battery status
Slow Blinking –
Not connected
Solid – Connected
Fast Blinking –
Sampling data
Off – Not connected
On– Connected
Solid red– Low battery
Blinking red–
Charging
Solid green–
Fully charged
3. Plug in PASPORT sensors, temperature probe, or voltage leads.
SPARKlink ports
PASPORT ports
Voltage port
Temperature port
4. Configure the interface for Capstone. ( See
)
Next step:
Connecting a 750 SCSI or 500 serial Interface
1. Use the A-to-mini-B USB cable (included with the 750 Interface) to connect the
USB port of the 750 Interface to a USB port on your computer (or a USB hub connected to the computer).
012-14016A 24
2 Getting Started
Connecting an interface
2. Connect the AC adapter to a wall outlet and to the AC adapter port on the rear of the 750 Interface.
3. Turn on the interface and hold the power button.
4. Configure the interface for Capstone. ( See
)
5. Add sensors. ( See
"Connecting a sensor with the 750 Interface": 41
)
Next step:
Connecting USB PASPORT Interfaces: such as the SPARK SLS,
SPARKlink, or Power Link
1. Use an A-to-mini-B USB cable (such as PASCO part PS-2528) to connect the smaller USB port of the SPARK SLS or SPARKlink to a USB port on your computer (or a USB hub connected to the computer).
2. Optionally connect the AC adapter (included with the SPARK SLS and SPARKlink) to a wall outlet and to the AC adapter port on the bottom of the device.
SPARK SLS power
AC adapter port
Power button
3. Plug in PASPORT sensors, temperature probe, or voltage leads.
012-14016A 25
SPARK SLS / SPARKlink ports
2 Getting Started
Connecting an interface
PASPORT sensors
Temperature Sensor Port
Voltage port
4. SPARK SLS: Press and hold the power button until the SPARK SLS screen turns on.
5. Configure the interface for Capstone. ( See
)
6. SPARK SLS: The SPARK SLS states it is connected to a computer. Disconnect the SPARK SLS from the computer to use it in standalone mode.
Next step:
Connecting an Xplorer GLX or Xplorer
1. Use an A-to-mini B USB cable (included) to connect the smaller USB port of the Xplorer GLX to a USB port on your computer (or a USB hub connected to the computer).
2. Optionally, connect the included AC adapter to a wall outlet and to the AC adapter port on the right side of the Xplorer GLX.
3. If the Xplorer GLX is not on, press and hold the power button until the green LED
012-14016A 26
2 Getting Started
Connecting a sensor on the front flashes.
4. Configure the interface for Capstone. ( See
)
Next step:
Connecting a sensor
Capstone software running on your computer receives data from one or more connected sensors through one or more interfaces. (At least one interface and sensor is required to collect data. (
See "What do I need to have a complete measurement system? ": 162
)
Follow these steps to connect a sensor to your computer.
Note: Capstone requires an interface to communicate with the sensor.
2. Plug in one or more sensors into the interface.
Click for instructions on select interfaces
"Connecting a sensor with the 850 Interface": 36
"Connecting a sensor with the 750 Interface": 41
"Connecting a sensor with the SPARK SLS, SPARKlink, SPARKlink
"Connecting a sensor with the Xplorer GLX": 50
"Connecting a sensor with the Digital Adapter or Photogate Port": 55
"Connecting a sensor with the Analog Adapter": 56
"Connecting a sensor with the AirLink2": 56
3. Add the sensor in Capstone Tip
1
PASPORT sensor
1
You can add sensors that are not connected to the interface. This is useful to author or prepare experiments in advance.
012-14016A 27
2 Getting Started
Connecting a sensor
Note: Capstone automatically detects properly connected PASPORT sensors.
Automatically detected PASPORT sensors
To manually add a PASPORT sensor:
012-14016A 28
a. Click within the yellow circle of the port to add a sensor.
Interface: PASPORTport indicators
2 Getting Started
Connecting a sensor b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Analog ScienceWorkshop sensor (Universal Interface)
012-14016A 29
2 Getting Started
Connecting a sensor
Note: Capstone automatically detects Universal Interface (UI) sensors.
To add a non-connected sensor to Capstone: a. Click within the yellow circle of the port to add a sensor.
Interface: Analog Port Indicators b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Digital sensor (ScienceWorkshop)
012-14016A 30
2 Getting Started
Connecting a sensor
Note: Capstone does not automatically detect most digital sensors.
a. Click within the yellow circle of the port to add a sensor.
Interface: Digital Port Indicators b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
c. Optional: to use the sensor as a timer, click Timer Setup in the Tools
Palette.
012-14016A 31
2 Getting Started
Connecting a sensor
Timer Setup button
Analog sensor (ScienceWorkshop)
Note: Capstone does not automatically detect most analog ScienceWorkshop sensors.
a. Click within the yellow circle of the port to add a sensor.
Interface: Analog Port Indicators b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
012-14016A 32
2 Getting Started
Connecting a sensor
Sensor icon
Analog sensors do not toggle between inactive and active and display as active (green line) even when disconnected.
Temperature sensor (SPARK SLS, SPARKlink, SPARKlink Air, and Xplorer GLX)
Note: Capstone automatically detects temperature sensors connected to the internal temperature sensor port.
To manually add a temperature sensor: a. Click within the yellow circle of the temperature port to add a temperature sensor .
Interface: Temperature port indicators two bottom circles
The sensor icon appears for the port.
012-14016A 33
2 Getting Started
Connecting a sensor
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Voltage sensor (SPARK SLS, SPARKlink, SPARKlink Air, and Xplorer GLX)
Note: Capstone automatically detects sound sensors connected to the internal sound sensor port.
To manually add a voltage sensor: a. Click within the yellow circle of the port to add a voltage sensor.
Interface: Voltage port indicators second circle from top
The sensor icon appears for the port.
012-14016A 34
2 Getting Started
Connecting a sensor
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Sound sensor (Xplorer GLX)
Note: Capstone automatically detects voltage sensors connected to the internal voltage sensor port.
To manually add a sound sensor: a. Click within the yellow circle of the port to add a sound sensor .
Interface: Sound port indicators top circle b. Select the GLX Sound Level Sensor or the GLX Sound Sensor.
The sensor icon appears for the port.
012-14016A 35
2 Getting Started
Connecting a sensor
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Next step:
Connecting a sensor with the 850 Interface
1. Plug in PASPORT sensors, digital ScienceWorkshop sensors, or analog ScienceWorkshop (black) sensors.
850 Universal Interface ports
Digital ScienceWorkshop –
4 ports
Analog ScienceWorkshop –
4 ports
PASPORT – 4 ports Tip
1
2. Add the sensor in Capstone:
PASPORT sensor
Note: Capstone automatically detects properly connected PASPORT sensors.
1
PASPORT sensors are automatically detected.
012-14016A 36
Automatically detected PASPORT sensors
2 Getting Started
Connecting a sensor
To manually add a PASPORT sensor:
012-14016A 37
a. Click within the yellow circle of the port to add a sensor.
Interface: PASPORTport indicators
2 Getting Started
Connecting a sensor b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Digital sensor (ScienceWorkshop)
Note: Capstone does not automatically detect most digital sensors.
012-14016A 38
a. Click within the yellow circle of the port to add a sensor.
Interface: Digital Port Indicators
2 Getting Started
Connecting a sensor b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
c. Optional: to use the sensor as a timer, click Timer Setup in the Tools
Palette.
Timer Setup button
012-14016A 39
2 Getting Started
Connecting a sensor
Analog sensor (ScienceWorkshop)
Note: Capstone does not automatically detect most analog ScienceWorkshop sensors.
a. Click within the yellow circle of the port to add a sensor.
Interface: Analog Port Indicators b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Analog sensors do not toggle between inactive and active and display as active (green line) even when disconnected.
Analog ScienceWorkshop sensor (Universal Interface)
Note: Capstone automatically detects Universal Interface (UI) sensors.
To add a non-connected sensor to Capstone:
012-14016A 40
a. Click within the yellow circle of the port to add a sensor.
Interface: Analog Port Indicators
2 Getting Started
Connecting a sensor b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Next step:
Connecting a sensor with the 750 Interface
1. Plug digital ScienceWorkshop sensors or analog ScienceWorkshop (black) sensors.
012-14016A 41
2 Getting Started
Connecting a sensor
750 Interface ports
Digital – 4 ports
Analog – 4 ports
2. Add the sensor in Capstone:
Digital sensor (ScienceWorkshop)
Note: Capstone does not automatically detect most digital sensors.
a. Click within the yellow circle of the port to add a sensor.
Interface: Digital Port Indicators b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
012-14016A 42
2 Getting Started
Connecting a sensor c. Optional: to use the sensor as a timer, click Timer Setup in the Tools
Palette.
Timer Setup button
Analog sensor (ScienceWorkshop)
Note: Capstone does not automatically detect most analog ScienceWorkshop sensors.
a. Click within the yellow circle of the port to add a sensor.
Interface: Analog Port Indicators b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Analog sensors do not toggle between inactive and active and display as active (green line) even when disconnected.
Analog ScienceWorkshop sensor (Universal Interface)
012-14016A 43
2 Getting Started
Connecting a sensor
Note: Capstone automatically detects Universal Interface (UI) sensors.
To add a non-connected sensor to Capstone: a. Click within the yellow circle of the port to add a sensor.
Interface: Analog Port Indicators b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Next step:
012-14016A 44
2 Getting Started
Connecting a sensor
Connecting a sensor with the SPARK SLS, SPARKlink, SPARKlink
Air
1. Plug in PASPORT sensors, temperature probe, and/or voltage leads.
SPARK ports
PASPORT – 2 ports
Temperature – 1 port
Voltage – 1 port
2. Press and hold the power button.
3. Configure the interface for Capstone. ( See
)
4. Add the sensor in Capstone:
PASPORT sensor
Note: Capstone automatically detects properly connected PASPORT sensors.
012-14016A 45
Automatically detected PASPORT sensors
2 Getting Started
Connecting a sensor
To manually add a PASPORT sensor:
012-14016A 46
a. Click within the yellow circle of the port to add a sensor.
Interface: PASPORTport indicators
2 Getting Started
Connecting a sensor b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Temperature sensor
Note: Capstone automatically detects temperature sensors connected to the internal temperature sensor port.
To manually add a temperature sensor: a. Click within the yellow circle of the temperature port to add a temperature sensor .
Interface: Temperature port indicators
012-14016A 47
The sensor icon appears for the port.
Sensor icon
2 Getting Started
Connecting a sensor
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Voltage sensor
Note: Capstone automatically detects sound sensors connected to the internal sound sensor port.
To manually add a voltage sensor: a. Click within the yellow circle of the port to add a voltage sensor.
Interface: Voltage port indicators
The sensor icon appears for the port.
012-14016A 48
2 Getting Started
Connecting a sensor
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Next step:
012-14016A 49
2 Getting Started
Connecting a sensor
Connecting a sensor with the Xplorer GLX
1. Plug in PASPORT sensors, temperature probe, or voltage leads.
Xplorer GLX ports
PASPORT – 4 ports
Temperature – 2 ports
Voltage – 1 port
2.
3. Press and hold the power button.
4. Configure the interface for Capstone. ( See
)
5. Add the sensor in Capstone:
PASPORT sensor
Note: Capstone automatically detects properly connected PASPORT sensors.
012-14016A 50
Automatically detected PASPORT sensors
2 Getting Started
Connecting a sensor
To manually add a PASPORT sensor:
012-14016A 51
a. Click within the yellow circle of the port to add a sensor.
Interface: PASPORTport indicators
2 Getting Started
Connecting a sensor b. Select the sensor to add from the drop down list.
The sensor icon appears for the port.
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Temperature sensor
Note: Capstone automatically detects temperature sensors connected to the internal temperature sensor port.
To manually add a temperature sensor: a. Click within the yellow circle of the temperature port to add a temperature sensor .
Interface: Temperature port indicators two bottom circles
012-14016A 52
The sensor icon appears for the port.
Sensor icon
2 Getting Started
Connecting a sensor
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Voltage sensor
Note: Capstone automatically detects sound sensors connected to the internal sound sensor port.
To manually add a voltage sensor: a. Click within the yellow circle of the port to add a voltage sensor.
Interface: Voltage port indicators second circle from top
The sensor icon appears for the port.
012-14016A 53
2 Getting Started
Connecting a sensor
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Sound sensor
Note: Capstone automatically detects voltage sensors connected to the internal voltage sensor port.
To manually add a sound sensor: a. Click within the yellow circle of the port to add a sound sensor .
Interface: Sound port indicators top circle b. Select the GLX Sound Level Sensor or the GLX Sound Sensor.
The sensor icon appears for the port.
012-14016A 54
2 Getting Started
Connecting a sensor
Sensor icon
Active: the connect line turns green when Capstone detects the sensor on an active interface. Inactive: the sensor is indicated as unconnected by a red connect line and an inactive symbol.
Next step:
Connecting a sensor with the Digital Adapter or Photogate Port
The Digital Adapter (PASCO part PS-2159) allows any ScienceWorkshop digital sensor sensors to be connected to a PASPORT interface to be used with Capstone. It also allows the use of the ScienceWorkshop Motion Sensor (CI-6742A) and the Rotary
Motion Sensor (CI-6538).
The Photogate Port (PS-2123) is an obsolete adapter that supports switch-type sensors, but not the Rotary Motion Sensor or Motion Sensor.
Procedure
1. Connect the adapter to your PASPORT interface.
2. Connect a digital sensor to the adapter.
You can connect a switch-type sensor to either port of the adapter.
If you are connecting a Motion Sensor or Rotary Motion Sensor, connect the yellow plug to Port 1 and the black plug to Port 2.
3. A list of digital sensors and sensor configurations appears.
4. Optionally, connect a second switch-type sensor to the other port of the adapter.
5. In the list, click one of the sensors or configurations to select it.
Next step:
012-14016A 55
2 Getting Started
Adding a display
Connecting a sensor with the Analog Adapter
The Analog Adapter (PASCO part PS-2158) allows analog ScienceWorkshop sensors to be connected to a PASPORT interface to be used with Capstone.
Procedure
1. Connect the Analog Adapter to your PASPORT interface.
2. Connect an analog sensor to the adapter.
A list of sensors appears.
3. Click one of the sensors to select it.
4. Optionally, click the Gain: box and click a gain setting.
5. Click OK.
Next step:
Connecting a sensor with the AirLink2
The AirLink2 sensor interface can communicate with computers using the USB connection or the via the bluetooth interface.
Next step:
Adding a display
Capstone provides a highly flexible environment for workbook page layout.
Pages can be created using any combination of templates, drag and drop to targets, and moving and resizing display elements.
Use a QuickStart template
1. Click one of the provided templates.
Tip
1
1
You can add or remove display elements after you select a template.
012-14016A 56
2 Getting Started
Adding a display
Page layout templates
2. The selected layout appears in the Display Area
3. Click <Select Measurement> for each display.
4. Select the measurement in the drop-down list.
Note: Sensors that are inactive (not ready to collect data) appear with .
(
See "Connecting an interface": 17
and
Use drag & drop and targets
1. Click one of the display icons in the Displays Palette.
See "Tour the Displays Palette ": 10
for a description of the available display types.
2. Drag the icon to the Display Area.
3. Use the Page layout targets to quickly format the page.
Using Page layout targets
1. Drag a display icon to one of the five targets.
2. Move the cursor around open area of the page.
3. The target turns darker as you approach it and is selected when the border on the target appears.
4. Drop the icon on a selected target.
Page targets divide the available area into the following five sections: Tip
1
Note: Page targets divide either an open area or an existing display.
1
Use targets to quickly divide an existing display into two displays.
012-14016A 57
2 Getting Started
Adding a display
Page layout targets entire available area (not used for splitting an existing display) left half (divided vertically–left half shows darker than right) right half (divided vertically–right half shows darker than left) top half (divided horizontally–top half shows darker than bottom) bottom half (divided horizontally–bottom half shows darker than top)
4. The selected layout appears in the Display Area Tip
1
5. Add more displays noting the Page layout targets.
6. Click the <Select Measurement> button for each display.
7. Select the measurement in the drop-down list.
Note: Sensors that are inactive (not ready to collect data) appear with .
(
See "Connecting an interface": 17
and
Moving and resizing
Capstone uses handles to move and resize individual displays on a page. Capstone includes vertical and horizontal alignment borders for easy display alignment.
Moving a display
1. Click on the display you wish to move to make it active.
1
You can add or remove display elements after you select a template.
012-14016A 58
2 Getting Started
Adding a display
2. Move the cursor until the border darkens and the move (hand) symbol appears.
Page layout move handle
3. Click and drag the display to new location.
Note: The alignment guides appear (dotted lines) when the display border aligns with adjacent displays.
Resizing a display
1. Click on the display to move to make it active.
2. Move the cursor to one of the eight resize handles (circle ).
Page layout resize handle
3. Click and drag the border to new position.
Note: The alignment guides appear (dotted lines) when the display border aligns with adjacent displays.
Realigning displays
1. Move the cursor between displays until the desired move border symbol appears.
012-14016A 59
2 Getting Started
Starting an experiment
Page layout realign handles
2. Click and drag the border to new position.
This action might affect multiple displays.
It might be necessary to move displays to align to a common alignment border. (
Next step:
Starting an experiment
Capstone provides several controls in the Controls Palette for collecting data.
Pre-work
1. Connect one or more interfaces. (
See "Connecting an interface": 17
)
2. Connect one or more sensors. (
See "Connecting a sensor": 27 )
3. Add one or displays. (
)
Note: Sensors that are inactive (not ready to collect data) appear with .
(
See "Connecting an interface": 17
and
Start data collection with default settings
Note: Measurements in displays that are inactive (not ready to collect data) appear with . Additionally, the data record button turns gray if there is not at least one active interface and sensor.
( See
and
)
012-14016A 60
1. Click Record in the Controls Palette.
Record button
2 Getting Started
Downloading Capstone experiments
Capstone begins recording all available data.
Record toggles to Stop .
2. Click Stop in the Controls Palette to stop data collection.
Collected data appear in all displays of the current page.
The data run is listed in the legend for each display.
Recorded data appear on the Sensor Data Summary tab ( ) in Data Sum-
mary, and is selectable from any data display with a default name Run #%1, where %1 is an automatically generated run number.
See "How do I record data in PASCO Capstone? ": 73
for details.
Removing data runs
n n
Delete Last Run: click Delete Last Run in the Controls Palette .
Delete Selected Runs: click the down arrow next to Delete Last Run and select a specific run.
n
Delete All Runs: click the down arrow next to Delete Last Run and select Delete All Runs.
Tip
1
Note: The run data is removed from all displays, legends, and the data summary.
Click the Undo button at the top to recover the data.
Next step (optional):
"Downloading Capstone experiments": 61
Downloading Capstone experiments
PASCO provides several ready-made experiments for Capstone.
Tip
2
1
You can delete all data for the run and repeat data collection.
2
The lab might contain multiple pages including: ◇ introduction ◇ theory ◇ setup & procedures ◇ analysis ◇ conclusions
012-14016A 61
2 Getting Started
Downloading Capstone experiments
1. Go to the Capstone experiments web page: http://www.pasco.com/family/capstone-experiments/index.cfm
2. Select a subject area, for example Thermodynamics.
3. Select the Free Experiments Files tab.
4. Scroll through the list of ready-made experiments and click to download the experiment files.
5. Copy the files from your download folder to your Capstone experiments folder.
The download might contain the following: l
Capstone application files; these have a ".cap" file extension l
Editable lab guides l
Images
6. Open the *.cap file from Capstone.
a. Click File > Open Experiment....
b. Navigate to the experiment file.
c. Click Open.
012-14016A 62
3 How do I...
3 How do I...
Installation and Update
"How do I automate a network installation?": 66
"How do I force an update to an interface?": 66
Experiment Files
"How do I download and open PASCO ready-made experiments?": 67
"How do I save my experiment?": 68
"How do I export all data?": 68
"How do I open DataStudio experiments and data?": 68
"How do I open Xplorer GLX, SPARK SLS, and other non-Capstone experiments and data?": 69
"How do I import data from Microsoft Excel*? ": 69
"How do I export data to Microsoft Excel*?": 70
"How do I import Xplorer GLX data?": 71
Data and Measurements
"How do I record data in PASCO Capstone? ": 73
"How do I delete data runs?": 79
"How do I choose one or more runs to display?": 79
"How do I identify a measurement when I have multiple of the same type?": 80
"How do I change the numerical format of data?": 81
"How do I change the numerical format of statistics?": 83
"How do I exclude, delete, and restore selected data?": 84
"How do I edit a measurement?": 87
"How do I create a pure mathematical function?": 87
Workbooks
"How do I show, hide, and lock the palettes?": 89
"How do I change what display toolbar buttons are visible?": 90
Sensors
"How do I zero a measurement?": 92
012-14016A 63
3 How do I...
"How do I switch the sign on a sensor?": 93
"How do I calibrate a sensor?": 94
"How do I calibrate a motion sensor?": 95
"How do I calibrate a drop counter?": 96
"How do I calibrate a pH sensor?": 97
Calculations
"How do I create a calculation? ": 99
"How do I use my calculation?": 102
"How do I select a measurement in the calculator?": 103
"How do I see the result of a calculation?": 103
"How do I reorder calculations?": 105
Plots
"How do I plot multiple measurements on separate plot areas with shared X-axis?": 107
"How do I zoom to a selection?": 108
"How do I pan and scale?": 110
"How do I select active data?": 111
"How do I plot multiple measurements on same plot with multiple Y-axes?": 113
"How do I plot multiple measurements on same plot with same Y-axes?": 114
"How do I apply a curve fit to a portion of the data?": 117
"How do I change curve fit parameters?": 118
"How do I adjust the weights for the weighted linear fit?": 119
"How do I lock and unlock the axes of a graph?": 121
"How do I change layer order of a display?": 123
Tables
"How do I reorder columns in a table?": 124
"How do I use a table to build data in Keep Mode?": 124
Text Boxes
"How do I enter subscripts, superscripts, Greek letters, and symbols?": 127
"How do I enter an equation into a text display?": 127
012-14016A 64
3 How do I...
Scope
"How do I compare scope traces from the same sensor when monitoring?": 130
"How do I select the scope trigger?": 131
"How do I freeze and record the scope display?": 135
Video
" How do I add a video source?": 137
"How do I analyze a video?": 138
"How do I manually synchronize video with data?": 140
"How do I adjust the frame rate of a recorded video?": 141
"How do I adjust the resolution of a video?": 141
"How do I make files with videos smaller?": 141
"How do I troubleshot video problems?": 142
012-14016A 65
3 How do I...
How do I... Installation and Update
How do I... Installation and Update
"How do I automate a network installation?": 66
"How do I force an update to an interface?": 66
How do I automate a network installation?
You must have a valid site license to perform a network installation. PASCO Capstone uses an InstallShield installer, which packages the Windows Installer (msi) into an executable setup file: PASCO_Capstone_Setup.exe
. Both the InstallShield installer and the packaged msi can be controlled using command line switches: See InstallShield
Note 1039936 for details on the InstallShield switches and Microsoft Note 227091 for information on the msi switches.
Below is an example of a silent installation:
1. Copy the installation file PASCO_Capstone_Setup.exe
that you have either downloaded or obtained from a CD to the root directory of your hard drive “C:”.
2. Go to Start > Run…
3. Type C:/PASCO_Capstone_Setup.exe /s /v"/qb" . ( /s = installer runs silently, /v = passes the parameter that follows immediately after in quotes to the msi installer, /qb = msi runs with no modal dialog boxes.)
4. Run the software.
5. Enter your license key when prompted.
6. After the license key is accepted, copy ResourceFiles.rc
located at C:\Documents and Settings\All Users\Application Data\PASCO Scientific\ResourceFiles.rc
(Windows XP) or C:\Program Data\PASCO
Scientific\ResourceFiles.rc
(Window 7) to the same location on the other computers by means of a batch copy command or other mechanism.
Contact
"Teacher and Technical Support": ii
for instructions to install on Windows 8 and
MAC.
How do I force an update to an interface?
PASCO Capstone prompts to update the interface if a new firmware version exists.
Follow these steps if an interface requires re-installing existing firmware to correct firmware corruption issues:
1. Unplug the interface from the USB port or turn it off.
2. Run PASCO Capstone.
3. Hold down CTRL + U while connecting or turning on the interface.
012-14016A 66
3 How do I...
How do I... Experiment Files
How do I... Experiment Files
"How do I download and open PASCO ready-made experiments?": 67
"How do I save my experiment?": 68
"How do I export all data?": 68
"How do I open DataStudio experiments and data?": 68
"How do I open Xplorer GLX, SPARK SLS, and other non-Capstone experiments and data?": 69
"How do I import data from Microsoft Excel*? ": 69
"How do I export data to Microsoft Excel*?": 70
"How do I import Xplorer GLX data?": 71
How do I download and open PASCO ready-made experiments?
PASCO provides several ready-made experiments for Capstone.
Tip
1
1. Go to the Capstone experiments web page: http://www.pasco.com/family/capstone-experiments/index.cfm
2. Select a subject area, for example Thermodynamics.
3. Select the Free Experiments Files tab.
4. Scroll through the list of ready-made experiments and click to download the experiment files.
5. Copy the files from your download folder to your Capstone experiments folder.
The download might contain the following: l
Capstone application files; these have a ".cap" file extension l
Editable lab guides l
Images
6. Open the *.cap file from Capstone.
a. Click File > Open Experiment....
b. Navigate to the experiment file.
c. Click Open.
1
The lab might contain multiple pages including: ◇ introduction ◇ theory ◇ setup & procedures ◇ analysis ◇ conclusions
012-14016A 67
3 How do I...
How do I... Experiment Files
How do I save my experiment?
Click File > Save Experiment.
All of the data, displays, toolbar states and formatting are saved.
Note: Deleted data and undo history are not saved.
How do I export all data?
1. Click File > Export Data...
2. Select a file type: Text (Tab delimited) (*.txt);CSV (Comma delimited) (*.csv).
3. Navigate to the location to save the file.
4. Click Save.
How do I open DataStudio experiments and data?
PASCO Capstone can open and convert most DataStudio 1.9 files to Capstone format.
1. Click File > Open Experiment...
2. Click on the file type pull-down menu, and select: DataStudio 1.9 files (*.ds)
3. Click Open.
Capstone places each display from the DataStudio on separate Capstone workbook pages.
Each display is sized to the full page.
Each page (tab) is named with the display name.
4. Recommended: save the experiment as a Capstone file. ( See "How do I save my experiment?": 68 )
5. Re-layout the Capstone pages as desired.
To combine multiple displays on a single page: a. Resize and move the display that will contain multiple displays to create a space for additional display(s). ( See
b. Click on page tab containing display to move.
c. Resize the display smaller than full page.
d. Select the display border, right click and select Cut.
012-14016A 68
3 How do I...
How do I... Experiment Files e. Click on the page, right-click and select Paste.
f. Resize and move as desired.
How do I open Xplorer GLX, SPARK SLS, and other non-Capstone experiments and data?
Xplorer GLX
PASCO Capstone can open and convert most DataStudio 1.9 and Xplorer GLX files to Capstone format.
(For files resident on the Xplorer GLX: see
"How do I import Xplorer GLX data?": 71 )
1. Click File > Open Experiment...
2. Click on the file type pull-down menu, and select: GLX Files (*.glx)
3. Click Open.
4. Recommended: save the experiment as a Capstone file. ( See "How do I save my experiment?": 68 )
Xplorer and 500 Dataloggers
TBD
SPARK SLS Experiments
TBD
How do I import data from Microsoft Excel*?
Tip
1
1. Open Microsoft Excel with the file containing your data.
2. Highlight the data within one column.
3. Press CTRL + C to copy the data.
4. Open PASCO Capstone.
5. Create a Table. ( See
6. Click on <Select Measurement> in a column.
1
Capstone supports export as tab-delimited text, which can be imported into almost any spreadsheet or data analysis program. Note that Capstone is a complete data collection, visualization, and analysis tool; therefore, it is generally easier to analyze the data in Capstone than to export to another software program for analysis.
012-14016A 69
3 How do I...
How do I... Experiment Files
7. Select Create New > User-Entered Data.
8. Optional: Rename the measurement and give it appropriate units.
9. Click in the cell of the User-Entered Data column where you would like to have the data pasted.
10. Press CTRL + V to paste.
11. Repeat for additional columns of data.
Each column of data is a separate data set.
Imported data are listed in the User-Entered Data Summary tab ( ) of Data
Summary.
How do I export data to Microsoft Excel*?
Tip
1
Export All Data
1. Select File > Export Data...
2. Select CSV (comma delimited) as the file type.
3. Click Save.
Export Selected Data
1. Create a Table. ( See
2. Select the data that you would like to copy: n
All data: click anywhere in the table and press CTRL + A .
n
All of the data in a column: click anywhere on the heading of the column where there is no text.
n
Visible part of a table: click and drag to select data.
3. Press CTRL + C to copy data to clipboard.
4. Open Microsoft Excel*.
5. Click in a cell where you would like the data to appear.
6. Press CTRL + V to paste data.
1
Capstone supports export as tab-delimited text, which can be imported into almost any spreadsheet or data analysis program. Note that Capstone is a complete data collection, visualization, and analysis tool; therefore, it is generally easier to analyze the data in Capstone than to export to another software program for analysis.
012-14016A 70
3 How do I...
How do I... Experiment Files
Note: You can define the format in Excel to include significant digits. (Format as Number with a defined number of decimal places.)
How do I import Xplorer GLX data?
To transfer experiments (including data files) from the Xplorer GLX to Capstone:
1. Connect the Xplorer GLX to Capstone.
2. Click Hardware Setup in the Tools Palette: .
Hardware Setup button
3. Click the yellow file folder icon next to the Xplorer GLX: .
GLX folder icon
012-14016A 71
3 How do I...
How do I... Experiment Files
4. Click Download All.
5. Navigate a folder and click Select Folder.
6. Click File > Open Experiment....
7. Select GLX Files (*.glx) from the file type drop down.
8. Navigate to the saved file .
9. Click Open.
Capstone opens the experiment and data for analysis and further data acquisition.
012-14016A 72
3 How do I...
How do I... Data and Measurements
How do I... Data and Measurements
"How do I record data in PASCO Capstone? ": 73
"How do I delete data runs?": 79
"How do I choose one or more runs to display?": 79
"How do I identify a measurement when I have multiple of the same type?": 80
"How do I change the numerical format of data?": 81
"How do I change the numerical format of statistics?": 83
"How do I exclude, delete, and restore selected data?": 84
"How do I edit a measurement?": 87
"How do I create a pure mathematical function?": 87
How do I record data in PASCO Capstone?
There are three data recording modes in PASCO Capstone. Data recording is controlled by the settings on the record tab of the Controls Palette.
Record modes
Continuous
Mode
Set to record data at the current sample rate settings
Keep Mode Set to keep data points when commanded
Fast Monitor Mode
Set to acquire data without recording; required for high speed sampling in Scope and FFT displays
Detailed Explanations
012-14016A 73
3 How do I...
How do I... Data and Measurements
Continuous Mode Set to record data at the current sample rate settings
Behavior l
All measurement Data
1 continuously records as soon as Record is clicked in the Controls Palette until the Stop is clicked (or the hardware is no longer able to process the data–at which time data collection will stop with an error message).
l
Data records at the specified sample rate(s).
See "What is Continuous Mode?": 168
Procedure
1. Select Continuous Mode in the Controls Palette.
2. Adjust the sample rates of each of the measurements:
Ensure sensors are sufficiently responsive for desired data while low enough so that the computer system can keep up with data sampling and does not generate excessive file sizes.
Sample Rate
3.
4. Click Record in the Controls Palette.
Record button
Capstone begins recording all available data.
Record toggles to Stop .
5. Click Stop in the Controls Palette to stop data collection.
Collected data appear in all displays of the current page.
1
A data set including measurement and user-defined data from sensors and time data.
012-14016A 74
3 How do I...
How do I... Data and Measurements
The data run is listed in the legend for each display.
Recorded data appear on the Sensor Data Summary tab ( ) in Data Sum-
mary, and is selectable from any data display with a default name Run #%1, where %1 is an automatically generated run number.
Keep Mode Set to keep data points when commanded
Behavior l
Manual recording mode.
l
The measurement sample rate(s) determine the rate at which data samples are
previewed (not recorded).
l
Data
1 records when and only when Keep Sample is clicked in the Controls
Palette while monitoring data.
l
One instance of all data is recorded each time Keep Sample is clicked.
Procedure
Tip: You can use a table with Keep Mode to build data for specific points. (
See "How do I use a table to build data in Keep Mode?": 124
)_
1. Select Keep Mode in the Controls Palette.
2. Adjust the sample rates of each of the measurements so that the sensors are sufficiently responsive for desired data.
Sample Rate
3. Click Preview in the Controls Palette.
Preview button
1
A data set including measurement and user-defined data from sensors and time data.
012-14016A 75
3 How do I...
How do I... Data and Measurements
Capstone begins monitoring data and displays previews.
Preview toggles to Stop .
Keep Sample button is active.
4. Click Keep Sample to record the data currently monitored.
One instance of all data is recorded.
Keep Sample button
5. Repeatedly click Keep Sample to record data.
One instance of all data is recorded each time Keep Sample is clicked.
6. Optional: Replace values in a table. ( See "Replacing a current value in a table":
Note: You can replace data in tables while in preview mode for the run (before clicking Stop ).
See
"How do I edit a measurement?": 87
to edit data after you click Stop .
7. Click Stop in the Controls Palette to stop observing the data.
Collected data appear in all displays of the current page.
The data run is listed in the legend for each display.
Recorded data appear on the Sensor Data Summary tab ( ) in Data Sum-
mary, and is selectable from any data display with a default name Run #%1, where %1 is an automatically generated run number.
012-14016A 76
3 How do I...
How do I... Data and Measurements
Fast Monitor Mode Set to acquire data without recording; required for high speed sampling in Scope and FFT displays
Behavior l
Intended for use with workbooks pages containing the FFT or Scope displays.
l
Designed for viewing periodic data or triggered transient events.
l
Monitor displays data without recording.
l
Snapshot records the monitored data.
l
Only Data
1 that is currently visible in the display is recorded each time
Snapshot is clicked.
l
Unsaved buffer data is also recorded when closing Capstone.
l
Can repeatedly monitor and record data points.
See "What is Fast Monitor Mode?": 169
Procedure
1. Select Fast Monitor Mode in the Controls Palette.
2. Adjust the sample rates of each of the measurements so that the sensors are sufficiently responsive for desired data.
Sample Rate
3. Select one or more scope or FFT displays. ( See
Note: To record a single event, use the scope display and click the single-shot button . ( See
"What does the Single Shot button do?": 178
)
4. Click Monitor in the Controls Palette.
1
A data set including measurement and user-defined data from sensors and time data.
012-14016A 77
3 How do I...
How do I... Data and Measurements
Monitor button
5. Click Stop in the Controls Palette to stop observing the data.
Monitor stop button
Capstone freezes the display.
7. Click Snapshot in the scope toolbar.
Scope Toolbar: Snapshot
Capstone records the data.
Notes:
Only the data that is visible in the plot area is recorded as a run when Snapshot is clicked.
Recorded data appear on the sensor tab in the Data Summary tab ( ), and is selectable from any data display with a default name Monitor Run--
ScopeSnapshot%1 where %1 is an automatically generated run number.
012-14016A 78
3 How do I...
How do I... Data and Measurements
How do I delete data runs?
n n
Delete Last Run: click Delete Last Run in the Controls Palette .
Delete Selected Runs: click the down arrow next to Delete Last Run and select a specific run.
n
Delete All Runs: click the down arrow next to Delete Last Run and select Delete All Runs.
Tip
1
Note: The run data is removed from all displays, legends, and the data summary.
Click the Undo button at the top to recover the data.
How do I choose one or more runs to display?
By default, PASCO Capstone displays the last run recorded or the currently selected measurement in Replay mode.
To select a different run to display:
1. Click the pull-down arrow ( ) next to Run Selection in the toolbar.
Toolbar: Run Selection button
2. Select the run to display.
To display multiple runs:
1
You can delete all data for the run and repeat data collection.
012-14016A 79
3 How do I...
How do I... Data and Measurements
1. Click to depress Run Selection in the toolbar.
Toolbar: Run Selection button
Selected runs display simultaneous with the button is depressed.
2. Click the pull-down arrow ( ) next to Run Selection
3. Select the one or more runs to display.
in the toolbar.
How do I identify a measurement when I have multiple of the same type?
One instance of a measurement
Format for a single instance of a specific measurement:
Measurement Type (units)
Example: Force (N)
Multiple instances of measurement–one interface connected
Format for multiple instances of a specific measure with one interface connected:
Measurement Type, Port (units)
Example: Force, Ch P1 (N)
Where:
Measurement Type = Force
Port on interface = P1 (Port identifier on the interface "P1" → PASPORT sensor number 1)
Multiple instances of measurement–multiple interfaces connected
Format for multiple instances of a specific measure with multiple interfaces connected:
Measurement Type, Channel:Port (units)
Example: Force, Ch A:P1 (N)
Where:
Measurement Type = Force
012-14016A 80
3 How do I...
How do I... Data and Measurements
Channel = A (Interface identifier "A")
Port = P1 (Port identifier on the interface "P1" → PASPORT sensor number 1)
Setup with multiple interfaces
Data Summary
Force, Ch A:P1 (N)
Force, Ch A:P2 (N)
Force, Ch B:1 (N)
How do I change the numerical format of data?
Note: Changing data precision correspondingly changes the precision of statistics that use the data.
012-14016A 81
1. Click Data Summary in the Tools Palette.
Data Summary button
3 How do I...
How do I... Data and Measurements
2. Click the Sensor Data tab .
3. Click the measurement to change.
4. Click Properties that appears to the right of the measurement.
The Properties window opens.
5. Click Numerical Format.
6. Set the desired numerical format:
Numerical Format
Number of Decimal Places
Apply Scientific Notation
Thresholds
Scientific Notation Thresholds
Description
Set the number of digits that will appear to the right of the decimal.
Select to enable Scientific Notation
Thresholds
Determines when the unit range transitions into scientific notation.
Lower Exponent
Threshold ≤
Upper Exponent
Threshold ≥
Apply limits for which the unit range transitions into scientific notation.
Apply Zero Level Thresholds
Apply Zero Level Thresholds
Select to enable Apply Zero Level
Thresholds
Apply the limit under which the number is considered to be zero.
7. Click OK.
012-14016A 82
3 How do I...
How do I... Data and Measurements
How do I change the numerical format of statistics?
Note: Changing data statistics precision correspondingly changes the precision of data.
To change the numerical format of the statistics, change the numerical format of the data on which the statistics are based.
1. Click Data Summary in the Tools Palette.
Data Summary button
2. Click the Sensor Data tab .
3. Click the measurement to change.
4. Click Properties that appears to the right of the measurement.
The Properties window opens.
5. Click Numerical Format.
012-14016A 83
3 How do I...
How do I... Data and Measurements
6. Set the desired numerical format:
Numerical Format
Number of Decimal Places
Apply Scientific Notation
Thresholds
Scientific Notation Thresholds
Lower Exponent
Threshold ≤
Upper Exponent
Threshold ≥
Apply Zero Level Thresholds
Apply Zero Level Thresholds
Description
Set the number of digits that will appear to the right of the decimal.
Select to enable Scientific Notation
Thresholds
Determines when the unit range transitions into scientific notation.
Apply limits for which the unit range transitions into scientific notation.
Select to enable Apply Zero Level
Thresholds
Apply the limit under which the number is considered to be zero.
7. Click OK.
How do I exclude, delete, and restore selected data?
Note: You can create User-Entered Data to copy and edit/delete data in the list. (
See
"How do I edit a measurement?": 87 )
Table
1. Highlight cells (click one cell or click and drag across multiple cells Tip
1
).
2. Exclude Selected Data: Right-click and select Exclude Data.
3. Delete Selected Data: Right-click and select Delete Cell Data.
Note: Excluded data are masked in the data set and are not used by Capstone for data operations including display and calculations. Excluded data can be restored at any time.
Note: Deleted data are removed from the data set and the data cannot be restored at a later time. You can immediately undo a delete action by clicking Undo .
1
Click the table heading to highlight all data in the table column.
012-14016A 84
Deleted and Excluded Data in a Table
3 How do I...
How do I... Data and Measurements
Deleted data are removed. Note the gap in time data.
Excluded data display with strikethrough.
Graph
1. Click Highlight range of points in active data in the toolbar.
Toolbar: Highlight Data button
2. Move and resize the selection rectangle as needed.
3. Exclude Selected Data: Right-click and select Exclusions > Exclude High-
lighted Data Points.
4. Delete Selected Data: Right-click and select Deletions > Delete Highlighted
Data Points.
5. Delete Excluded Data: Right-click and select Deletions > Delete ALL Excluded
Data Points.
Note: Excluded data are masked in the data set and are not used by Capstone for data operations including display and calculations. Excluded data can be restored at any time.
Note: Deleted data are removed from the data set and the data cannot be
012-14016A 85
3 How do I...
How do I... Data and Measurements restored at a later time. You can immediately undo a delete action by clicking Undo .
Deleted and Excluded Data in a Plot
Deleted data are removed.
Excluded data display with "X" marks.
To restore excluded data
Table
1. Highlight excluded cells.
Tip
1
2. Right-click and select Restored Excluded Data
Graph
1. Click Highlight range of points in active data in the toolbar.
Toolbar: Highlight Data button
2. Move and resize the selection rectangle as needed to highlight excluded data points.
3. Restore Selected Data: Right-click and select Exclusions > Restore Excluded
Data Points Within Highlighter's Bounds.
4. Restore All Data: Right-click and select Exclusions > Restore ALL Excluded
Data Points.
1
Click the table heading to highlight all data in the table column.
012-14016A 86
3 How do I...
How do I... Data and Measurements
How do I edit a measurement?
Measurements cannot be edited directly in PASCO Capstone. You can create User-
Entered Data to copy and edit/delete data in the list.
Note: You can use Exclude Data to exclude selected data from analysis and Displays. ( See
"How do I exclude, delete, and restore selected data?": 84
)
1. Create a Table. ( See
2. Click <Select Measurement> in the first column.
3. Select the measurement you would like edit.
4. Click <Select Measurement> in the second column.
5. Select Create New > User-Entered Data.
6. Click on the top of the first column.
7. Right click and select Copy Values (or use CTRL + C ).
8. Click in the first cell of the User Data %1 (where %1 is serial number) column.
9. Right-click and select Paste Values (or use CTRL + V ).
10. Edit data in cells: a. Change values in cells as needed.
b. Highlight cells and right-click to select: Clear Values, Insert Cells, Delete
Cell Data, or Exclude Data as needed.
11. Click on User Data %1 in the column heading, select rename, and enter a meaningful name and units.
Imported data are listed in the User-Entered Data Summary tab ( ) of Data
Summary.
How do I create a pure mathematical function?
Graph a purely mathematical function by defining a model
1 culation on the model within the calculator.
and then creating a cal-
Procedure
1. Create a model in the calculator.
a. Open the Calculator. ( See
"How do I create a calculation? ": 99
) b. Right click on a new calculation line and select Insert Model Range.
1
A sequence of values within a range and a defined number of steps or step size.
012-14016A 87
3 How do I...
How do I... Data and Measurements
The Edit Model Range Properties window opens.
c. Set the Start Value: of the range.
d. Set the End Value: of the range.
e. Select option:
Option Action
Step
Count:
Step
Size:
Set the number of values between the Start
Value and End Value.
Set the increment size between values in the range. A smaller step size will produce more values in the range and a larger step size will produce fewer values in the range.
Example Format:
{0 .. 10;100}
Start
Value: 0; End
Value: 10; Step
Count: 100
{0 .. 10;+1}
Start
Value: 0; End
Value: 10; Step
Size: 1
2. Click OK.
Calculations appear on the Calculation Data Summary tab ( ) in Data Sum-
mary, and are selectable from any data display. ( See "How do I use my calculation?": 102 )
Example in Calculator
y = {0 .. 10;100} z = sin(y)^2 w = integral([y(units)],y)
Where: y is a model z and w are functions based on model y.
012-14016A 88
3 How do I...
How do I... Workbooks
How do I... Workbooks
"How do I show, hide, and lock the palettes?": 89
"How do I change what display toolbar buttons are visible?": 90
How do I show, hide, and lock the palettes?
1. Right-click anywhere in the gray area surrounding a workbook page.
Right-click in area surrounding display
2. Show/hide: click the palette that you would like to show ( ) or hide ( ).
012-14016A 89
3 How do I...
How do I... Workbooks
3. Lock/unlock: click Lock Page to lock ( ) or unlock page ( ).
Locked pages: n
Displays cannot be added or removed.
n
Text Entry Box elements are active and accept user entries.
n
Displays can be scaled and panned.
How do I change what display toolbar buttons are visible?
1. Click on Visibility Menu in the display Toolbar.
Toolbar: Visibility Menu button
If the Visibility Menu button is not available: right-click anywhere in the gray
012-14016A 90
3 How do I...
How do I... Workbooks area surrounding a workbook page and deselect Lock Page.
Right-click in area surrounding display
2. Click the buttons that you would like to show ( ) or hide ( ) on the toolbar.
012-14016A 91
3 How do I...
How do I... Sensors
How do I... Sensors
"How do I zero a measurement?": 92
"How do I switch the sign on a sensor?": 93
"How do I calibrate a sensor?": 94
"How do I calibrate a motion sensor?": 95
"How do I calibrate a drop counter?": 96
"How do I calibrate a pH sensor?": 97
How do I zero a measurement?
Note: If a sensor is selected in the Controls Palette that supports zeroing, the Controls
Palette includes a Zero Sensor Now button .
Procedure
1. Connect the sensor to PASCO Capstone. ( See
2. Click Hardware Setup in the Tools Palette: .
Hardware Setup button
3. Click on the sensor to zero.
4. Click Properties in the lower right corner of the Hardware Setup window.
The Properties window opens.
5. Select option:
012-14016A 92
3 How do I...
How do I... Sensors
These options will not appear for sensors that do not have these capabilities.
Option
Zero Sensor Measurements at Start
Zero Sensor Now
Description
Zero this sensor's measurements each time a new run is recorded.
Zero this sensor's measurements when the button is clicked.
6. Click OK.
How do I switch the sign on a sensor?
Method 1: configuring sensor (that supports sign change)
1. Click Hardware Setup in the Tools Palette: .
Hardware Setup button
2. Click on the sensor to Change Sign.
3. Click Properties in the lower right corner of the Hardware Setup window.
4. The Properties window opens.
5. Click Change Sign .
This option will not appear for sensors that do not have this capability.
6. Click OK.
The sensor automatically switches the sign when recording data.
Method 2: using QuickCalc (any sensor)
1. Create a Table. ( See
2. Click <Select Measurement> and select the measurement to change sign.
012-14016A 93
3 How do I...
How do I... Sensors
3. Click QuickCalc in the toolbar.
Toolbar: QuickCalc button
A new table column is added with a default calculation that includes the selected measurement.
4. Rename the calculation to something meaningful.
5. Add a negative sign in the calculation before the measurement.
Example: ForceA=-[Force(N)]
6. Press Enter .
The new column is the opposite sign of the original measurement data.
7. Click on the units in the new column and change to something meaningful.
Calculations appear on the Calculation Data Summary tab ( ) in Data Sum-
mary, and are selectable from any data display. ( See "How do I use my calculation?": 102 )
Method 3: using Calculator (any sensor)
Example: ForceA=-[Force(N)]
Calculations appear on the Calculation Data Summary tab ( ) in Data Summary, and are selectable from any data display. ( See
"How do I use my calculation?": 102
)
How do I calibrate a sensor?
PASCO Capstone includes calibration wizards for many sensors.
Procedure
1. Connect the sensor to PASCO Capstone. ( See
2. Click Calibration in the Tools Palette.
012-14016A 94
Calibration button
3 How do I...
How do I... Sensors
3. Follow the instructions within Capstone.
Sensors that do not have a wizard in Capstone will not be listed.
For detailed procedures, see:
"How do I calibrate a motion sensor?": 95
"How do I calibrate a pH sensor?": 97
"How do I calibrate a drop counter?": 96
"Can multiple measurements be calibrated simultaneously?": 175
How do I calibrate a motion sensor?
1. Connect the Motion Sensor to PASCO Capstone.
2. Place a marker at one meter from the face of the motion sensor.
3. Record the distance to the marker reported by the motion sensor.
4. Click Data Summary in the Tools Palette.
012-14016A 95
Data Summary button
3 How do I...
How do I... Sensors
5. Click the Sensor Data Summary tab .
6. Click on the Motion Sensor properties icon .
7. Divide the value in the Speed of Sound (m/s) field by the recorded distance in meters (from step 3).
8. Enter the calculated value (from step 7) in the Speed of Sound (m/s) field.
9. Click OK.
How do I calibrate a drop counter?
1. Connect the Drop Counter to PASCO Capstone. ( See "Connecting a sensor":
2. Measure the volume from the Drop Counter for 10 drops.
3. Calculate the volume per drop (divide volume from step 2 by 10).
4. Click Data Summary in the Tools Palette.
012-14016A 96
Data Summary button
3 How do I...
How do I... Sensors
5. Click the Sensor Data Summary tab .
6. Click on the Drop Counter properties icon .
7. Enter the calculated value (from step 3) in the Drop Volume (mL) field.
8. Click OK.
How do I calibrate a pH sensor?
Note: Simultaneous calibration is not recommended for pH, ISE, ORP, Conductivity, stainless-steel temperature sensors without insulating sleeves, or Disolved Oxygen sensors because these sensors will not read correctly if the probes are placed in the same solution simultaneously.
Equipment Required
Two aqueous pH buffer standards that bracket the pH values of interest.
Procedure
1. Connect the pH Sensor to PASCO Capstone. ( See
)
2. Click Calibration in the Tools Palette.
012-14016A 97
Calibration button
3 How do I...
How do I... Sensors
3. Choose the probes you would like to calibrate now: pHMeasurement
4. Click Next.
5. Choose the type of calibration you would like to perform: Two Standards (2
point).
6. Click Next.
7. Enter the first known pH buffer value in the Standard Value text box.
8. Rinse and dry the pH Sensor probe.
9. Place the probe in the corresponding buffer solution.
10. Stir the probe until the Current Value stabilizes.
11. Click the Set Current Value to Standard Value button.
12. Click Next.
13. Enter the second known pH buffer value in the Standard Value text box.
14. Rinse and dry off the probe.
15. Place the probe in the second buffer solution.
16. Stir the probe until the value Current Value stabilizes.
17. Click the Set Current Value to Standard Value button.
18. Click Next.
19. Click Finish.
Repeat the calibration procedure for other pH sensors using different probes.
012-14016A 98
3 How do I...
How do I... Calculations
How do I... Calculations
"How do I create a calculation? ": 99
"How do I use my calculation?": 102
"How do I select a measurement in the calculator?": 103
"How do I see the result of a calculation?": 103
"How do I reorder calculations?": 105
How do I create a calculation?
Note: Calculations appear on the Calculation Data Summary tab ( ) in Data Sum-
mary , and are selectable from any data display. ( See "How do I use my calculation?": 102 )
Tips
l
Capstone supports simple to highly-complex calculations using a combination of math functions, measurements, user-defined data, constants, and text labels including symbols.
l
Use either the keyboard or the Calculator keypad for numbers and simple operators.
l
Add parenthesis to explicitly define order of operation.
l
Multiplication is implied with adjacent arguments. Insert the * symbol to explicitly denote multiplication.
l
Type: [ to quickly insert measurements (or click Insert Data ).
Procedure
1. Click Calculator in the Tools Palette.
012-14016A 99
Calculator button
3 How do I...
How do I... Calculations
The Calculator dialog opens.
2. Use a combination of
, text, calculator functions, and numerals to create a calculation.
The calculation is displayed Calculations list.
Invalid or incomplete calculations are indicated with red font.
See
"How do I select a measurement in the calculator?": 103
See
"How do I see the result of a calculation?": 103
See
"How do I reorder calculations?": 105
See
"How do I use my calculation?": 102
Example Procedure:
1 x = at + vt + x
2
2
0
Define the following equation:
1 x = at + vt + x
2
2
0
Where: x = Position (calculated) a = Acceleration (measured)
012-14016A 100
v = Velocity (measured) t = Time (measured) x
0
= initial position (user-created constant)
1. Click Calculator in the Tools Palette.
Calculator button
3 How do I...
How do I... Calculations
The Calculator dialog opens.
2. Click in a new line of Calculations.
3. Create the constant x
0.
: a. Type: x b. Click xₒ, select 0 c. Type: = d. Type: 0
4. Click in a new line of Calculations
5. Type: x=1/2(
6. Type: [ (or click Insert Data ).
A pop-up list opens.
7. Select the appropriate Acceleration measurement from the drop down list.
8. Type: [ (or click Insert Data ).
012-14016A 101
3 How do I...
How do I... Calculations
9. Select the Time measurement from the drop down list.
10. Click x².
11. Type: + (or click + )
12. Type: [ (or click Insert Data ).
13. Select the appropriate Velocity measurement from the drop down list.
14. Type [ (or click Insert Data ).
15. Select the Time measurement from the drop down list.
16. Type: + (or click + )
17. Type: [ (or click Insert Data ).
18. Select the Constants (under Equations/Constants) measurement from the drop down list.
19. Select x
0
.
20. Click in the Units field.
21. Type: m and select m/s² from the list.
22. Press Enter or Accept .
Example Calculations
Constant1=2*3
Calc1=[Acceleration(m/s²)]^2
Γ^2=sin([Angle(rad)])
Φ=integral([Force(N)],[Time(s)])
Resultant Acceleration=sqrt(([Acceleration- x(m/s²)]^2+[Acceleration- y(m/s²)]^2+[Acceleration- z(m/s²)]^2))
How do I use my calculation?
Note: Calculations appear on the Calculation Data Summary tab ( ) in Data Sum-
mary , and are selectable from any data display. ( See "How do I use my calculation?": 102 )
1. Create a calculation. ( See
"How do I create a calculation? ": 99
)
2. Click <Select Measurement> in any display.
012-14016A 102
3 How do I...
How do I... Calculations
3. Select the calculation or constant to use under Equations/Constants.
4. Select the run to display. ( See "How do I choose one or more runs to display?":
How do I select a measurement in the calculator?
Method 1
1. Position cursor for placement of measurement.
2. Click Insert Data .
A pop-up list opens.
3. Select the measurement from the list.
Method 2
1. Right-click anywhere within the calculation to place the measurement.
A pop-up menu opens.
2. Select Insert Data from the menu.
3. Select the measurement from the list.
Method 3
1. Position cursor for placement of measurement.
2. Enter a left-bracket “[ “.
A pop-up list opens.
3. Select from the measurement from the list.
How do I see the result of a calculation?
Note: Calculations appear on the Calculation Data Summary tab ( ) in Data Sum-
mary , and are selectable from any data display. ( See "How do I use my calculation?": 102 )
Constants Only
If the calculation uses constants (no measurements) such that the calculation evaluates to a single number, then the result of the calculation is displayed in the result status line.
012-14016A 103
Result status line
3 How do I...
How do I... Calculations
Constants can also be viewed in a table or other display, see below.
Includes Variables (measurements)
The results are calculated using MathML and are associated with data runs. Calculated data can be viewed in a table or other display.
1. Create a calculation. ( See
"How do I create a calculation? ": 99
)
2. Click <Select Measurement> in any display.
3. Select the calculation or constant to use under Equations/Constants.
4. Select the run to display. ( See "How do I choose one or more runs to display?":
Example Calculations
Constant1=2*3
Calc1=[Acceleration(m/s²)]^2
Γ^2=sin([Angle(rad)])
Φ=integral([Force(N)],[Time(s)])
012-14016A 104
3 How do I...
How do I... Calculations
Resultant Acceleration=sqrt(([Acceleration- x(m/s²)]^2+[Acceleration- y(m/s²)]^2+[Acceleration- z(m/s²)]^2))
How do I reorder calculations?
Method 1
1. Click and drag the calculation that you would like to move.
2. When the colored insert line is at the desired insertion point, release the mouse button.
Method 2
1. Click the calculation that you would like to move to select it.
2. Use the arrow keys in the Calculator window.
012-14016A 105
3 How do I...
How do I... Plots
How do I... Plots
"How do I plot multiple measurements on separate plot areas with shared X-axis?": 107
"How do I zoom to a selection?": 108
"How do I pan and scale?": 110
"How do I select active data?": 111
"How do I plot multiple measurements on same plot with multiple Y-axes?": 113
"How do I plot multiple measurements on same plot with same Y-axes?": 114
"How do I apply a curve fit to a portion of the data?": 117
"How do I change curve fit parameters?": 118
"How do I adjust the weights for the weighted linear fit?": 119
"How do I lock and unlock the axes of a graph?": 121
"How do I change layer order of a display?": 123
012-14016A 106
3 How do I...
How do I... Plots
How do I plot multiple measurements on separate plot areas with shared X-axis?
Attributes of multiple plot areas
The plots share the same x-axis measurement.
The y-axes are independent.
The plots from the different measurements do not overlap.
See "How do I plot multiple measurements on same plot with multiple Y-axes?":
See "How do I plot multiple measurements on same plot with same Y-axes?":
Procedure
1. Click Add new plot area to the Graph display in the toolbar.
Toolbar: Add New Plot button
2. Click <Select Measurement> on the plot and choose the measurement for the vertical axis.
012-14016A 107
3 How do I...
How do I... Plots
3. To delete a plot area and its corresponding plots, click on the plot area and click Remove active element, axis, or plot area .
Note: You will not be allowed to have fewer than one plot area. Use Delete
Selected Display in main toolbar to remove the display. (Scope display does not allow multiple plots.)
How do I zoom to a selection?
Zoom in
1. If multiple runs are visible, click on the symbol corresponding to the plot to zoom in the legend.
Legend: selecting the active plot
Symbol and color in legend matches plot symbol and color. Click legend to make active. (The active plot is shaded in legend and darkest in display.)
Click in the upper left corner of the legend to clear all active runs.
2. Click Data Highlighter in the toolbar.
Toolbar: Highlight Data button
A rectangle appears on the graph that is the same color as the target plot.
012-14016A 108
3 How do I...
How do I... Plots
3. Click and drag anywhere within the highlighter to move it.
4. Click and drag the handles to resize the highlighter rectangle to the area to zoom.
Selected data is highlighted in yellow.
5. Click Scale to Fit in the toolbar.
Toolbar: Scale-to-fit button
The plot zooms to the selected section.
6. Optional: Remove the highlight rectangle: a. Click the highlight rectangle b. Press Delete to remove the rectangle
Zoom out
1. Remove the highlight rectangle: a. Click the highlight rectangle b. Press Delete to remove the rectangle
2. Click Scale to Fit in the toolbar.
Toolbar: Scale-to-fit button
The plot zooms out to include all data.
012-14016A 109
3 How do I...
How do I... Plots
How do I pan and scale?
Panning and Scaling
Note: If the plot does not pan or scale: see "How do I lock and unlock the axes of a graph?": 121 .
Panning Moving the origin within the display. Scale does not change.
1. Click within the plot area (except for the legend) and drag the plot in any direction.
2. Release the mouse button when the origin is in the desired location.
Scaling Changing the axis scale (value between tick marks) to zoom-in or zoom-out. Origin does not change.
Click and Drag Method
1. Click on an axis to scale.
2. Drag away from origin to decrease scale (zoom-in).
3. Drag toward the origin to increase scale (zoom-out).
Scroll Wheel Method
1. Move the cursor to a location on an axis to scale.
2. Scroll back to decrease scale (zoom-in).
3. Scroll forward to increase scale (zoom-out).
012-14016A 110
3 How do I...
How do I... Plots
Scaling is performed on the axis at the point of the cursor.
Tip
1
Zooming around a point Changing the scale and origin around a single point.
1. Move the cursor to a location on a point to remain stationary (except for the legend).
2. Scroll back to decrease scale (zoom-in).
3. Scroll forward to increase scale (zoom-out).
How do I select active data?
By default, the last selected measurement of the last run is the active run.
To make another plot active: l
Click on the symbol corresponding to that plot in the legend ( in the example)).
Legend: selecting the active plot
Symbol and color in legend matches plot symbol and color. Click legend to make active. (The active plot is shaded in legend and darkest in display.)
Click in the upper left corner of the legend to clear all active runs.
To clear all active runs:
1 ◇ Place the cursor at the origin to maintain the origin point or use click and drag method. ◇ Place the cursor at the intersection of two axis to scale simultaneously.
012-14016A 111
3 How do I...
How do I... Plots l
Click in the upper left corner of the legend ( in the example).
Legend: selecting the active plot
Symbol and color in legend matches plot symbol and color. Click legend to make active. (The active plot is shaded in legend and darkest in display.)
Click in the upper left corner of the legend to clear all active runs.
Toolbars (including data functions):
Toolbars are active when a single display is active, and will only apply to the active display.
For displays with multiple plots, the toolbar actions apply to the active plot within the display.
012-14016A 112
3 How do I...
How do I... Plots
How do I plot multiple measurements on same plot with multiple Yaxes?
Attributes of multiple Y-axes
Measurements scale independently( except for the rescaling required to make the alignment of the tick mark values on each side of the graph match up).
The order of the axes may be changed once multiple axes are created.
Plots from different measurements use the same plot area and may overlap.
See "How do I plot multiple measurements on separate plot areas with shared Xaxis?": 107
See "How do I plot multiple measurements on same plot with same Y-axes?":
Procedure
1. Create a graph display. ( See
2. Click Add new y-axis to active plot area . (Click multiple times to add multiple axes.)
Toolbar: Add Y-axis button
3. Click <Select Measurement> and choose the measurements for each vertical axis.
4. Optional: reorder axes:
012-14016A 113
3 How do I...
How do I... Plots a. Click Allow rearrangement of axes and plot areas in the toolbar.
Toolbar: Rearrange Y-axes and plots button b. Drag and drop axes one at a time.
Axes can reside on the left, right, or a combination of both sides of the display.
c. Click Allow rearrangement of axes and plot areas .
Exits re-arrangement mode.
Remove an axis
Click on axis to remove. (Must not be in re-arrangement mode.)
Click Remove active element, axis, or plot area .
Toolbar: Remove button
Note: You will not be allowed to have fewer than one plot area. Use Delete Selected
Display in main toolbar to remove the display. (Scope display does not allow multiple plots.)
How do I plot multiple measurements on same plot with same Yaxes?
PASCO Capstone allows one measurement on the x (independent variable) axis and multiple measurements on the y (independent variable) axis. Y-axis labels can be placed on either side. If the measurements share the same measurement type, then the measurements can be plotted with a shared Y-axis.
012-14016A 114
3 How do I...
How do I... Plots
Attributes of multiple measurements with a shared Y-axis
Measurements must share the same measurement type. The shared generic Measurement Type name is displayed on the Y-axis.
Measurements scale together.
Plots from different measurements use the same plot area and may overlap.
See "How do I plot multiple measurements on separate plot areas with shared Xaxis?": 107
See "How do I plot multiple measurements on same plot with multiple Y-axes?":
Procedure
1. Create a graph display. ( See
2. Click <Select Measurement> and select one of the measurements to display on the vertical Y-axis.
3. Click Data Summary in the Tools Palette.
012-14016A 115
3 How do I...
How do I... Plots
Data Summary button
4. Click the Sensor Data tab .
5. Click and drag another measurement of the same measurement type to the graph display.
6. Repeat for additional sensors of same type.
The shared generic Measurement Type name is displayed on the Y-axis.
Multiple-Y-axes
012-14016A 116
3 How do I...
How do I... Plots
How do I apply a curve fit to a portion of the data?
1. Select the plot to fit by clicking on its corresponding symbol in the legend.
Legend: selecting the active plot
Symbol and color in legend matches plot symbol and color. Click legend to make active. (The active plot is shaded in legend and darkest in display.)
Click in the upper left corner of the legend to clear all active runs.
2. Click Data Highlighter in the toolbar.
Toolbar: Highlight Data button
A rectangle appears on the graph that is the same color as the target plot.
3. Click and drag anywhere within the highlighter to move it.
4. Click and drag the handles to resize the highlighter rectangle.
Selected data is highlighted in yellow.
5. Click the down arrow ( ) on Curve Fit .
6. Select the curve fit that you wish to apply to the selected data from the pull-down menu.
012-14016A 117
3 How do I...
How do I... Plots
Note: Move the highlighter rectangle to see fits for different regions. (Capstone will not simultaneously perform curve fits on two or more different regions of the same data set.)
How do I change curve fit parameters?
PASCO Capstone supports modifying curve fit parameters for high-precession fits. (Initial curve fits are usually automatic and accurate.)
Procedure
Curve Fit Editor button
2. Select the plot to fit by clicking on its corresponding symbol in the legend.
012-14016A 118
3 How do I...
How do I... Plots
Legend: selecting the active plot
Symbol and color in legend matches plot symbol and color. Click legend to make active. (The active plot is shaded in legend and darkest in display.)
Click in the upper left corner of the legend to clear all active runs.
3. Click Curve Fit Editor in the Toolbar.
4. Enter the value to modify in the Initial Guess box of the corresponding parameter.
5. Click the Lock check box ( ) next to parameter.
Locks the manual entry. Capstone will not overwrite.
6. Repeat for each parameter to modify.
7. Click the Update Fit button.
The curve fit in the graph uses the manually entered values.
Repeat steps to iteratively improve the curve fit.
To reset to default settings and unlock parameter values, click Reset.
8. Click Curve Fit Editor in the Toolbar to close the editor.
How do I adjust the weights for the weighted linear fit?
The weights for the weighted linear fit come from the errors in the data set. To define the error associated with each data value:
012-14016A 119
1. Click Data Summary in the Tools Palette.
Data Summary button
3 How do I...
How do I... Plots
2. Click the Sensor Data tab .
3. Click the measurement to change.
4. Click Properties that appears to the right of the measurement.
The Properties window opens.
5. Click the Errors section.
6. Define the error type and values.
Error
Type
Default
Absolute
Error
Default
Minimum
Display
Value
Default
Maximum
Display
Value
Description
Specifies the default absolute error value for this measurement and is used when Default Errors are in effect.
Sets the default minimum scale value for this measurement when it is initially selected in some data displays.
Sets the default maximum scale value for this measurement when it is initially selected in some data displays.
Error Bar
Type
Select the type of error bar to display. Choose Default Error to set the length of the error bars equal to the default absolute error of the data. Choose Percent of Value to set the length of the error bars equal to the specified percentage of each data point value. Choose
Fixed Range to set the length of the error bars to equal specific val-
012-14016A 120
Error
Type
3 How do I...
How do I... Plots
Description ues. Choose Measurement to use a User Entered Data Set or other
Measurement to define error values for individual data points.
Resets the error settings for this measurement to defaults.
Reset
How do I lock and unlock the axes of a graph?
PASCO Capstone has several options for locking the axes of a graph from Panning and Scaling.
Panning and Scaling
Lock panning or scaling from both user and data changes
1. Deselect Scaling Method . in the Display Toolbar.
Toolbar: Scaling Method button
Capstone will not scale to the data.
2. Right click on an axis and select one or both: l
Lock Axis Panning l
Lock Axis Scale
012-14016A 121
Users cannot manually pan or scale.
3. Optional: repeat for additional axes.
4. Click Show or hide tools in the Display Toolbar.
Toolbar: Visibility Menu button
5. Deselect Scale to Fit in the list.
Users cannot scale to fit.
6. Click anywhere in Capstone to close Show or hide tools.
Lock scaling from data changes only
Deselect Scaling Method . in the Display Toolbar.
Toolbar: Scaling Method button
3 How do I...
How do I... Plots
Capstone will not scale to the data.
Lock panning or scaling from user changes only
1. Right click on an axis and select one or both: l
Lock Axis Panning l
Lock Axis Scale
Users cannot manually pan or scale.
2. Optional: repeat for additional axes.
3. Click Show or hide tools in the Display Toolbar.
Toolbar: Visibility Menu button
012-14016A 122
3 How do I...
How do I... Plots
4. Deselect Scale to Fit in the list.
Users cannot scale to fit.
5. Click anywhere in Capstone to close Show or hide tools.
How do I change layer order of a display?
1. Click on the display to make it active. ( See
"How do I select active data?": 111
)
2. Right-click on the border of the display.
3. Select: Send To Back or Bring To Front.
Send To Back = places display at the bottom of the stack.
Bring To Front = places display at the top of the stack.
012-14016A 123
3 How do I...
How do I... Tables
How do I... Tables
"How do I reorder columns in a table?": 124
"How do I use a table to build data in Keep Mode?": 124
How do I reorder columns in a table?
1. Click on an empty part of the column header.
2. Drag until the blue column marker indicates the desired location for the column.
3. Release the mouse button.
How do I use a table to build data in Keep Mode?
Procedure
1. Create a table for the measurement to capture. (
)
2. Optional: Create User-Entered Data into one column of the table.
3. Click in the first cell to record data.
4. Select Keep Mode in the Controls Palette.
5. Adjust the sample rates of each of the measurements so that the sensors are sufficiently responsive for desired data.
Sample Rate
6. Click Preview in the Controls Palette.
Preview button
012-14016A 124
Capstone begins monitoring data and displays previews.
Preview toggles to Stop .
Keep Sample button is active.
7. Click Keep Sample to record the data currently monitored.
One instance of all data is recorded.
The cursor advances to the next table cell.
Keep Sample button
3 How do I...
How do I... Tables
8. Repeatedly click Keep Sample to record data.
One instance of all data is recorded each time Keep Sample is clicked.
The cursor advances to the next table cell on each Keep Sample.
9. Optional: Replace values in a table. ( See "Replacing a current value in a table":
Note: You can replace data in tables while in preview mode for the run (before clicking Stop ).
See
"How do I edit a measurement?": 87
to edit data after you click Stop .
10. Click Stop in the Controls Palette to stop observing the data.
Collected data appear in all displays of the current page.
The data run is listed in the legend for each display.
Recorded data appear on the Sensor Data Summary tab ( ) in Data Sum-
mary, and is selectable from any data display with a default name Run #%1, where %1 is an automatically generated run number.
Replacing a current value in a table
1. While previewing data, click in the cell to change.
The current monitored value is displayed with the existing value.
012-14016A 125
3 How do I...
How do I... Tables
Replace data in table cell
Existing value
New value
Click Keep Sample to replace the existing value with the new value.
2. Click Keep Sample to replace the existing value with the new value.
The cursor advances to the next table cell.
3. Perform one of the following options: n
Continue to replace values.
n
Click in empty cell to record additional data.
n
Click Stop in the Controls Palette to stop observing the data.
Note: You can replace data in tables while in preview mode for the run
(before clicking Stop ).
See
"How do I edit a measurement?": 87
to edit data after you click
Stop .
012-14016A 126
3 How do I...
How do I... Text Boxes
How do I... Text Boxes
"How do I enter subscripts, superscripts, Greek letters, and symbols?": 127
"How do I enter an equation into a text display?": 127
How do I enter subscripts, superscripts, Greek letters, and symbols?
New: enter subscripts, superscripts or symbols
1. Right-click in any area that accepts text such as: text box, text entry, name, or calculator fields.
2. Select one of the following: l
Insert Superscript l
Insert Subscript l
Insert Upper Case Greek Letter l
Insert Lower Case Greek Letter l
Insert Special Character
3. Select the character to insert from the drop-down list.
Existing: subscript or superscript selected text (text and text entry boxes only)
1. Highlight existing text.
2. Right-click and select one of the following: l
Superscript Selected Text l
Subscript Selected Text
How do I enter an equation into a text display?
1. Create the equation using an application capable of exporting MathML as plain text.
2. Paste into a Text Box or Text Entry Box in PASCO Capstone. ( See "Adding a display ": 56 )
012-14016A 127
3 How do I...
How do I... Text Boxes
Using Microsoft Word* (2007/2010)
1. Switch to MathML mode (if needed): a. Click Insert > Equation > Insert new equation.
b. Select the arrow at the lower right of the tools part of the ribbon.
Equation options button
012-14016A 128
c. Select Copy MathML to the clipboard as plain text
MathML to clipboard selection
3 How do I...
How do I... Text Boxes d. Click OK.
2. Type the equation in the programs equation editor.
3. Highlight the equation.
4. Press CTRL + C to copy.
5. Switch to a Text Box or Text Entry Box in PASCO Capstone.
6. Place the cursor and press CTRL + V to paste.
012-14016A 129
3 How do I...
How do I... Scope
How do I... Scope
"How do I compare scope traces from the same sensor when monitoring?": 130
"How do I select the scope trigger?": 131
"How do I freeze and record the scope display?": 135
How do I compare scope traces from the same sensor when monitoring?
1. Select one of the traces that you would like to compare with later traces by clicking on the symbol corresponding to that plot in the legend.
Legend: selecting the active plot
Symbol and color in legend matches plot symbol and color. Click legend to make active. (The active plot is shaded in legend and darkest in display.)
Click in the upper left corner of the legend to clear all active runs.
2. Click Snapshot in the toolbar to capture the visible trace.
012-14016A 130
3 How do I...
How do I... Scope
Scope Toolbar: Snapshot
3. Click Run Selection .
Multiple runs can display simultaneous when the button is depressed.
4. Click the pull-down arrow ( ) next to Run Selection in the toolbar.
Scope Toolbar: Run Selection button
5. Select the measurement trace snapshots that you would like to display.
See
"How do I record data in PASCO Capstone? ": 73
How do I select the scope trigger?
Note: If the trigger button in the scope toolbar is depressed, the display of data starts when the trigger condition is satisfied. If the trigger button is not depressed, the display of data starts immediately.
The trigger in the scope applies to the rightmost measurement on the left of the scope plot area.
I. Select Measurement for Trigger:
012-14016A 131
3 How do I...
How do I... Scope
1. Click on the measurement name on the immediate left of the scope.
Scope Trigger: Right-most measurement on left
2. Select the measurement for the trigger from the drop-down list.
–Or–
1. Click Allow rearrangement of axes in the toolbar.
Scope Toolbar: Allow rearrangement of axes
2. Click and drag the measurement to use as the trigger to the immediate left of the scope.
012-14016A 132
Scope Trigger: Right-most measurement on left
3 How do I...
How do I... Scope
II. Turn on Trigger:
1. Click Trigger in the toolbar.
Scope toolbar: Trigger button
2. Click the pull down menu of the trigger
3. Select: l
Positive Edge l
Negative Edge
A trigger indicator is displayed on the plot.
.
012-14016A 133
3 How do I...
How do I... Scope
Trigger Indicator n
Indicators point up for Positive Edge and down for Negative Edge triggers.
n
Trigger indicator color matches run color.
How do I
?
Note: An 850 Universal Interface is required to use the pre-trigger functionality.
1. Click Trigger in the toolbar.
Scope toolbar: Trigger button
2. Click the pull down menu of the trigger
3. Select: l
Positive Edge l
Negative Edge
A trigger indicator is displayed on the plot.
.
012-14016A 134
3 How do I...
How do I... Scope
Trigger Indicator n
Indicators point up for Positive Edge and down for Negative Edge triggers.
n
Trigger indicator color matches run color.
4. Pan the scope display to the right, so that the left edge of the viewing area is at the time before the trigger. ( See
"How do I pan and scale?": 110 )
How do I freeze and record the scope display?
( See
"How do I record data in PASCO Capstone? ": 73
for information on Fast Monitor Mode.)
1. Select Fast Monitor Mode in the Controls Palette.
2. Adjust the sample rates of each of the measurements so that the sensors are sufficiently responsive for desired data.
Sample Rate
3. Select one or more scope or FFT displays. ( See
Note: To record a single event, use the scope display and click the single-shot button . ( See
"What does the Single Shot button do?": 178
)
4. Click Monitor in the Controls Palette.
012-14016A 135
3 How do I...
How do I... Scope
Monitor button
5. Click Stop in the Controls Palette to stop observing the data.
Monitor stop button
Capstone freezes the display.
7. Click Snapshot in the scope toolbar.
Scope Toolbar: Snapshot
Capstone records the data.
Notes:
Only the data that is visible in the plot area is recorded as a run when Snapshot is clicked.
Recorded data appear on the sensor tab in the Data Summary tab ( ), and is selectable from any data display with a default name Monitor Run--
ScopeSnapshot%1 where %1 is an automatically generated run number.
012-14016A 136
3 How do I...
How do I... Video
How do I... Video
" How do I add a video source?": 137
"How do I analyze a video?": 138
"How do I manually synchronize video with data?": 140
"How do I adjust the frame rate of a recorded video?": 141
"How do I adjust the resolution of a video?": 141
"How do I make files with videos smaller?": 141
"How do I troubleshot video problems?": 142
How do I add a video source?
PASCO Capstone supports most driverless (UVC 1.1) USB video sources, which includes almost all newer web cameras, USB microscopes, and telescopes, and many older USB video sources that require drivers.
Procedure
1. Connect a driverless (UVC 1.1) USB video source, such as a web camera, microscope, or telescope.
2. Drag and drop a Movie Display from the Displays Palette to a workbook page.
( See
3. Select one of the four choices presented in the display:
Option
Open Movie
File
Definition
Use for Prerecorded QuickTime compatible videos.
Capture
Image*
Record
Explanatory
Movie*
Use to capture a still image. (Do not use for video analysis.)
Use for videos that will not be synchronized to data. (The video records without data recording.)
Record
Movie with
Synced
Data*
Use for a movie that you wish to keep synchronized to sensor data that will be recorded simultaneously. (The video records with data recording.)
*A live video is displayed in Movie Display.
Note: While recording, sound output from the camera is muted by default in order to prevent feedback loops between the microphone and computer speakers. You may
012-14016A 137
3 How do I...
How do I... Video unmute the recorder in the Movie Display properties. There are separate volume/muting controls available for playback and recording.
How do I analyze a video?
You can manually track the path of objects in any recorded or compatible pre-recorded movie.
Tips for good results
l
PASCO Capstone analyzes in two dimensions. Position the camera plane parallel to the plane of motion. (That is, point the camera perpendicular to the plane of motion.) l
Place the camera approximately at the center of the path of the object of interest.
l
Use intense lighting (such as sunlight) to avoid motion blurring that might obscure the image.
Procedure
1. Add a camera. ( See
" How do I add a video source?": 137 )
2. Add a Movie Display ( See
3. Select a type of Movie Display:
Option Definition
Open Movie
File
Capture
Image*
Use for Prerecorded QuickTime compatible videos.
Use to capture a still image. (Do not use for video analysis.)
Record
Explanatory
Movie*
Record
Movie with
Synced
Data*
Use for videos that will not be synchronized to data. (The video records without data recording.)
Use for a movie that you wish to keep synchronized to sensor data that will be recorded simultaneously. (The video records with data recording.)
*A live video is displayed in Movie Display.
If using Open Movie File, skip to step 5.
4. Prepare recording.
a. Place a physical ruler (or object of known length) in the movie scene to determine scale.
b. Ensure the plane of action is parallel to the plane of the lens of the camera.
012-14016A 138
5. Record movie.
Using Record Explanatory Movie: a. Start Recoding: click Record in the Display toolbar.
The video records without data recording.
Toolbar: Video Record button
3 How do I...
How do I... Video b. Stop Recoding: click Record in the Display toolbar.
Using Record Movie with Synced Data: a. Start Recording: click Record in the Controls Palette.
The video records with data recording.
Record button b. Stop Recording: click Stop in the Controls Palette.
6. Click Enter video analysis mode in the Display toolbar.
Toolbar: Video Analysis button
7. Select the data run to use.
8.
Optional: Change the units or length of the scale.
a. While in Video Analysis mode, click toolbar properties .
b. Click Enter video analysis mode.
012-14016A 139
3 How do I...
How do I... Video c. Modify as needed: Real World Length (Sets Real World Length In Specified
Units).
d. Modify as needed: Data Units (Sets Length Units).
9. Adjust the scale tool to match the scale of the ruler (or object of known length) in the scene.
10. Click on the object that you would like to track.
Capstone places a + at the point of click and the video will advance to the next frame.
11. Repeat until the object has been completely tracked.
The video analysis data appear on the Video Data Summary tab ( ) in the Data Summary, and are selectable from any data display.
12. Open a Display (such as a Table, Graph, or Histogram). ( See "Adding a display
13. Click <Select Measurement> in the display and select a video analysis measurement: l x-Position l y-Position l x-Velocity l y-Velocity l x-Acceleration l y-Acceleration
How do I manually synchronize video with data?
1. Add a Video Display. ( See
" How do I add a video source?": 137 )
2. Open and existing video recording or record new video.
3. Add a table or graphic display with the data to use. ( See "Adding a display ":
The page contains two displays: video of experiment and numerical data.
4. Click Playback Mode in the Controls Palette.
5. Click the Play in the Controls Palette.
6. Playback the recorded data until an identifiable event occurs. (For example, the point of collision.)
7. Click Manually synchronize movie with data in the Video toolbar.
012-14016A 140
3 How do I...
How do I... Video
8. Click View/adjust current movie playback position in the Video toolbar.
A slider appears under .
9. Adjust the video slider until the video frame corresponds to the time of the identifiable event from step 6.
10. Click Manually synchronize movie with data in the Video toolbar.
How do I adjust the frame rate of a recorded video?
Frequently high-speed or low-speed video files contain false frame rate metadata. Camera manufactures deliberately do this so that the video plays back at a easily-viewable frame rate. For PASCO Capstone to synchronize the video correctly, the video rate in the file must be accurate.
Procedure
Change frame rate metadata of the video file, using a free video editor:
1. Download and install Avidemux .
2. Right click on your video file and select Open with... .
3. Select Avidemux.
4. In Avidemux, select Video.
5. Select Frame Rate.
6. Check Use Custom Frame Rate and set the desired frame rate.
7. Save the file.
8. For adjusting the phase between the video and the data, see Tech Note #493 .
How do I adjust the resolution of a video?
The settings for all movies are 320×240×30 fps in order to keep file sizes low. A USB 2.0
camera is unlikely to drop frames at this rate. Higher resolutions or frame rates increases the probability of dropped frames.
How do I make files with videos smaller?
PASCO Capstone saves files as uncompressed. Select a compression codec to reduce the file size of recorded videos. The available codecs vary by computer, and some codecs may result in a movie that is not playable within PASCO Capstone.
012-14016A 141
3 How do I...
How do I... Video
Procedure
1. Add a movie to the workbook. ( See
" How do I add a video source?": 137 )
2. Click on properties in the video toolbar.
3. Click Movie Recording.
4. Click the Video Compression drop-down.
5. Select a video compression algorithm.
Note: The compression algorithms available depend on the operating system and the software installed by the video camera. Different compression algorithms affect different properties of the video file including frame rate and frame size.
6. Click OK.
7. Test: play the video in Capstone.
If the video no longer plays in Capstone, repeat steps and select a different algorithm.
How do I troubleshot video problems?
Dropped Frames and Automatic Synchronization
The video sensor attempts to synchronize the movie with the data. This might not work if too many operating system processes are running simultaneously. (Windows and MAC are not a real time operating systems, and modern installations might have up to hundreds of processes running. The operating system can decide to let other process to have priority, resulting in dropped frames or synchronization issues.)
To improve performance of the auto-synchronization algorithm: l
Increase the sensor sample rate within Capstone l
Terminate unused processes in the operating system l
Temporarily disable virus scanners in operating system l
Turn off the internet connection in operating system
Capture Sound Issues
Some cameras are not automatically able to assign a matching microphone. If you are missing sound:
1. Click on properties in the video toolbar.
2. Click the View/adjust current movie playback position drop-down.
012-14016A 142
3 How do I...
How do I... Video
Choose a microphone. Some computers may not automatically choose the correct microphone. In these cases, you may select a camera and a microphone, and then choose "Save Defaults" to associate the camera and microphone.
Click OK.
3. Test video recording and playback.
If no audio, repeat steps to select a different Microphone source.
Windows Drivers
Open Device Manager: My Computer > Properties > Manage > Device Manager
> Imaging Devices
If the camera does not appear in the Device Manager, try another USB port or disconnecting and reconnecting the camera to the same USB port.
If the camera appears in the Device Manager, click on it and press the delete button, unplug and replug the device into the USB port. Install the latest device driver provided by the manufacturer if requested.
l
Devices that support the UVC (USB Video Class 1.1) standard do not need to have any special drivers installed to function in XP-SP3 or Windows Vista/7/8.
Such devices appear automatically in Device Manager shortly after being connected.
l
Older devices will need a driver installed.
l
Older 16 Bit Devices (VFW devices) are not plug and play, and will appear to still exist after they have been physically disconnected. To uninstall such devices, right click on the device in Device Manager and select “uninstall driver”
Testing in Windows
Windows Vista/Windows 7 Testing
Windows Vista/7 does not include a built-in video viewer. A simple utility that allows you to test a webcam in Windows Vista/7 can be found here: http://www.bustatech.com/webcamviewer-a-simple-viewer-for-webcam/ .
You can also use “Skype” or any other video-chat capable program to test a webcam.
Windows XP Testing
Note: SP3 (Service Pack 3) is required.
1. Close PASCO Capstone
2. Open Windows Explorer.
3. Look under Scanners and Cameras.
4. Click on the camera in use.
012-14016A 143
A window opens displaying the camera output.
5. Take a snapshot to test the camera.
3 How do I...
How do I... Video
012-14016A 144
4 Frequently Asked Questions (FAQ)
4 Frequently Asked Questions (FAQ)
PASCO Capstone
"What is PASCO Capstone?": 147
"Where can I find help documentation and curriculum for PASCO Capstone?": 147
"What are the new features in the latest PASCO Capstone?": 148
"Can PASCO Capstone open DataStudio, SPARKlab, and GLX files?": 151
"Can Capstone files be opened on computers with different operating systems?": 151
"How does Capstone compare to other PASCO applications? ": 152
Installation and Updates
"What licenses are required?": 160
"Is an MSI available for PASCO Capstone?": 160
"Do I need to update the interfaces?": 161
"Do I need to update the sensor datasheets?": 161
Setup
"What do I need to have a complete measurement system? ": 162
"Can sensors sample at different rates?": 167
Data files
"Where is my data saved?": 165
"What is the file export format?": 165
"What is the format for text import?": 166
Data and Measurements
"Which data is recorded?": 167
"Can sensors sample at different rates?": 167
"What is Continuous Mode?": 168
"What is Fast Monitor Mode?": 169
"Is there a way to delete data points?": 170
"How are the curve fit and smoothing calculations determined?": 172
012-14016A 145
4 Frequently Asked Questions (FAQ)
Calculations and Calibration
"What is the format for calculations?": 174
"What are the equations for calibration?": 174
"Can multiple measurements be calibrated simultaneously?": 175
Displays
"What is panning and scaling?": 176
"Why are the display toolbars not active?": 177
Scope
"What does the Single Shot button do?": 178
"What is pre-triggering in the scope?": 179
Video and Text
"What cameras and video formats are supported?": 180
"Why does the text color remain black after picking a color?": 180
012-14016A 146
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone
FAQ... PASCO Capstone
"What is PASCO Capstone?": 147
"Where can I find help documentation and curriculum for PASCO Capstone?": 147
"What are the new features in the latest PASCO Capstone?": 148
"Can PASCO Capstone open DataStudio, SPARKlab, and GLX files?": 151
"Can Capstone files be opened on computers with different operating systems?": 151
"How does Capstone compare to other PASCO applications? ": 152
What is PASCO Capstone?
PASCO Capstone is a feature-rich data acquisition, visualization, and analysis program designed by PASCO scientific for advanced science education. In addition, Capstone contains the tools needed for the creation and execution of structured scientific inquiries, by allowing simple drag-and-drop integration of rich text, graphics, video, and data displays on multiple page displays called workbooks.
Capstone is completely compatible with all PASCO USB Interfaces, including the 850
Universal Interface, Xplorer GLX, SPARKlink, SPARKlink Air, SPARK SLS, USB Link and older interfaces such as the ScienceWorkshop 750 or 500.
See
Where can I find help documentation and curriculum for PASCO
Capstone?
Where can I find Capstone documentation?
PASCO Capstone is designed to be as intuitive as possible. In addition the following
Help is available:
012-14016A 147
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone l
Tool Tips: hover over a button to view the associated tool tip.
Tool tips: hover over button...
l
Context Help: helpful information at the bottom of dialog windows. ( See
) l
Online Help: searchable instructions on working with PASCO Capstone, frequently asked questions, and links to instructional videos.
Click Help > PASCO Capstone Help (or F1) l
Teacher Support: for specific questions that are not answered by these resources. ( See
"Teacher and Technical Support": ii )
What curriculum is available for Capstone?
A number of Capstone experiments designed for the 850 Universal Interface can be downloaded. ( See
"Downloading Capstone experiments": 61 )
In addition, PASCO Capstone can open and convert many DataStudio 1.9.x and GLX files. ( See
"How do I open DataStudio experiments and data?": 68
)
What videos are available for Capstone?
A number of Capstone experiments are on the PASCO http://www.youtube.com/user/pascoscientific ) channel. ( See
What are the new features in the latest PASCO Capstone?
The following features are new to version 1.1:
n
Localization (Input Method Editor support) n
Support for MacOS 10.6 + n
Histogram Display
012-14016A 148
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone o Different modes: side-by-side, overlay, stacked o Statistics o Coordinates tool n
Video Analysis o Manual tracking of objects o Video analysis can be done on a movie recorded as “sensor” data or an opened movie file. Can make measurements on a “Captured” image.
n
Expansion Port Support o o o
Control the visibility of the UI 850 expansion port by clicking on the icon in upper right of Hardware Setup.
Click on an analog port and turn it into a Voltage or Peak Amplitude input. These
‘measurements’ will show up in the Data Summary under 850 Expansion Port. For the digital ports, the user can configure either an input or an output.
An input produces a State measurement and can also be used as an input for a
Custom Timer. An output can be manipulated using a new Digital Output tool that appears.
n
Journal o o o o
Two new buttons on main toolbar: one to take the Snapshot and the other to show/hide the journal.
Snapshot options include taking a snap of entire page with palettes, the white content area, or the currently selected display.
Within the journal, one can edit the title or annotation, rearrange snapshots, view full-screen, export to HTML, print, delete, etc.
The journal can also be re-sized or floated.
n
Exclusions/Deletions o Can be done either in the Table or Graph.
o o
Exclusions remove data from statistics, curve fits, and auto-scaling behavior but are still visible as and X on a graph or as stricken-through numbers in the Table display.
Deleting data eliminates the data visually and removes it from any analysis.
o
Excluded or deleted data may be recovered at any time before the Capstone workbook is closed. n
GLX File Import o
One can either use File Open, or the GLX File Management dialog you get when you click the folder icon next to a picture of the Xplorer GLX in the Hardware Setup window to import data from the Xplorer GLX into Capstone.
012-14016A 149
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone n
Import/Export Data o An Import data… and Export data…options appear in the File menu, allowing the import and export of tab-delimited text. Successfully imported text will appear in the user-entered data tab of the Data Summary window.
n
User-defined error bars o
One can now set error values for individual data points. o o
One can set different positive and negative error values by specifying different measurements for positive and negative (defaults to assuming you want the same for both).
One could even use a calculation on a measurement to specify error values.
n
Customization options o
Workbook page shape options, including new default best fit.
o Can set default font size for workbook displays.
o
Application preferences, including putting your preferences in an external, shared file.
n
Improved Print quality n
Linear fits weighted based on error bar values.
n
Moving digital probes and analog sensors (via Hardware Setup) n
New Add Similar Measurement menu on graph measurement picker. The ability to add multiple measurements to the same axis has been available for drag/drop but this was not very visible to the user. This new menu item makes that more visible. For example, add eight Force measurements to the same axis. Conserves space and assures that all measurements get scaled with the same axis. The legend becomes the means for identifying what is what. Tries to match the generic measurement type and unit of measurements. n
Graph smoothing slider now has a pop-up with on/off option.
n
Graph Curve Fit button has on/off.
n
Improved and additional formatting options for the graph coordinates tool.
n
Added Peak Amplitude Sensor and Frequency Sensor to the 850 Signal Generator outputs. This feature is useful for LRC sweep of Peak Amplitude versus Frequency.
n
Added a Peak Amplitude Sensor to analog inputs for 850, which can be used simultaneously with a Voltage sensor on the same channel.
n
Added a new “special” calculation, diff, which, for a single measurement, returns a set of the current value – n th previous value.
n
Added support for the AirLink2 and SPARKLink Air.
012-14016A 150
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone n
Displays can 'preview' data in when you have Start condition and Keep sampling.
n
Help (English only, initially oriented toward Tasks and Goals)
Can PASCO Capstone open DataStudio, SPARKlab, and GLX files?
Can PASCO Capstone open DataStudio files?
Yes.
PASCO Capstone can open and convert most DataStudio 1.9 files to Capstone format.
See
"How do I open DataStudio experiments and data?": 68
Can PASCO Capstone open SPARKlabs?
No.
PASCO Capstone cannot open SPARKlabs.
Can PASCO Capstone open saved GLX files?
Yes.
PASCO Capstone can open and convert most Xplorer GLX files to PASCO Capstone format.
See
"How do I open DataStudio experiments and data?": 68
Can PASCO Capstone transfer files from the Xplorer GLX?
Yes.
PASCO Capstone can transfer most Xplorer GLX files for use in Capstone.
See
"How do I import Xplorer GLX data?": 71
Can Capstone files be opened on computers with different operating systems?
Yes.
PASCO Capstone files (.cap) that are created on either a Mac or PC can be opened on another computer running another Capstone-compatible operating system (Mac OS, Windows) with the same version or later of Capstone.
012-14016A 151
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone
How does Capstone compare to other PASCO applications?
Specification
Availability
PASCO Part Numbers
Development Status
Supported Languages
PASCO Capstone
DataStudio
1.8.9r10
SPARKvue 2.0
Computer version: www.pasco.com
www.pasco.com
UI-5400
UI-5401
Active
English español de
América latina
(Latin American
Spanish)
简 体 字 (Simplified Chinese) le français
(French)
ﺔﻴﺑﺮﻌﻟا (Arabic) www.pasco.com
CI-6870
CI-6859C
Pad version:
Apple App Store /
Google Play Store
Computer version:
PS-2400
PS-2401
CI-6871
Inactive
ﺔﻴﺑﺮﻌﻟا (Arabic)
Pad version: N/A
Active
English
簡 體 字 (Traditional Chinese)
Dansk (Danish)
Deutsch (German)
简 体 字 (Simplified Chinese)
Dansk (Danish)
English español de
América latina
(Latin American
Spanish)
Suomi (Finnish) le français
(French) español de
México (Mexican
Spanish)
Deutsch (German) español castellano (Spanish) italiano (Italian) français canadien
(Canadian
French)
J日 本 語 (Japanese) le français
(French)
Norsk (Norwegian) italiano (Italian) português brasileiro
(Brazilian Portugese)
Nederlands
(Dutch)
Norsk (Norwegian)
Русский (Russian) español casportuguês brasileiro
(Brazilian Por-
012-14016A 152
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone
Specification
SUPPORTED OPERATING
SYSTEMS
INTENDED AUDIENCE
PASCO Capstone
DataStudio
1.8.9r10
SPARKvue 2.0
tugese) português de Portugal (Portugese)
Suomi (Finnish)
Svenska
(Swedish)
Türk (Turkish)
Český (Czech) tellano (Spanish)
Svenska
(Swedish)
Türk (Turkish)
Русский (Russian)
Казак (Kazakh)
ﺔﻴﺑﺮﻌﻟا (Arabic)
簡 體 字 (Traditional Chinese)
简 体 字 (Simplified Chinese)
J日 本 語 (Japanese)
한 국 의 (Korean)
ไ ท ย (Thai)
Windows XP 32bit
Windows XP 32bit
MacOS 10.6-10.8
Windows XP 32bit
Windows 7 32/64bit
Windows 8 32/64bit
Windows 7 32/64bit (requires special installation)
MacOS 9.x, 10.7
Windows 7 32/64bit
Windows 8 32/64bit
MacOS 10.5-10.8
Apple iOS 5.1
Apple iOS 6.0
Post-secondary /
Advanced High-
School Science
Educators
Post-secondary /
Advanced High-
School Science
Educators
Android
Elementary/Middle
School/ Introductory Secondary Science
012-14016A 153
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone
Specification
PASCO Capstone
DataStudio
1.8.9r10
SPARKvue 2.0
Supported Hardware
PASPORT
PS-2100(A) USB Link
PS-2001 PowerLink
PS-2009 SPARKlink
PS-2000 Xplorer
PS-2002 Xplorer GLX External
Sensors
PS-2002 Xplorer GLX Sound/
Sound Level
PS-2008(A) SPARK SLS
WIRELESS
PS-2005 AirLink SI
PS-2010 AirLink2
PS-2011 SPARKLink Air
Universal (PASPORT/ScienceWorkshop)
UI-5000 850 interface
ScienceWorkshop
ScienceWorkshop 300
CI-6760 ScienceWorkshop
500
CI-6560 ScienceWorkshop
700
YES
YES
YES
ACQUIRE ONLY
YES
YES
ACQUIRE ONLY
NO
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
NO via CI-6759A only Serial / CI-6759A
NO
YES
YES
YES
NO
YES
YES
CI-7500 ScienceWorkshop
750 –SCSI via CI-6759A only
SCSI / Serial /
CI-6759A
CI-7599 ScienceWorkshop
750 – USB
GENERIC DEVICES
USB video cameras
YES
YES
YES
Microphones
850 or SW750
+ sound sensor
YES
YES
YES
YES
ACQUIRE ONLY
NO
ACQUIRE ONLY
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
Waveport + Builtin Microphone /
ScienceWorkshop 750 + sound sensor
YES
Computer version:
YES
Pad version:
As part of video sensor only
THIRD-PARTY HARDWARE
Ocean Optics Red
Tide/Amadeus/ USB 2000 or
4000 spectrometers
NO NO
Educators
Computer version:
YES
Pad version:
NO
012-14016A 154
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone
Specification
Ohaus Scout Pro balances
Software Features
ACQUISITION
Timer Wizards
Independent sampling rates
Per-page sample rates
Directly Import Data From
SPARK SLS
Directly Import Data From
Xplorer GLX
EXPORT
Copy & Paste
PASCO Capstone
NO
YES
YES
YES
NO
YES
DataStudio
1.8.9r10
YES
NO
YES
NO
NO
YES
SPARKvue 2.0
NO
NO
NO
NO
NO
NO
Menu Option
From Table
All Measurements
From Summary
One Measurement
NO
All Measurements
IMPORT
Copy & Paste
Menu Option
CALIBRATION
To Table
YES
To Summary
YES
NO
NO
Calibration
Calibration types
Ability to return to factory defaults.
Analysis
Calculations
Immediate evaluation of constant expressions
Reorder calculations
Right-click selection of measurements
Right-click selection of models
Right-click selection of functions
Right-click selection of symbols
Right-click selection of sub-
/superscripts
Curve Fits
Standard Fits
ScienceWorkshop & select PASPORT
Sensors
ScienceWorkshop & select PASPORT
Sensors
1 pt slope, 1 pt offset, 2 pt linear
1 pt slope, 1 pt offset, 2 pt linear
Select PASPORT
Sensors
1 pt slope, 1 pt offset, 2 pt linear
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
NO
NO
NO
NO
NO
NO
YES
NO
YES
YES
NO
NO
NO
NO
NO
NO
YES
012-14016A 155
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone
Specification
Error-weighted Linear Fit
Editable Initial Guesses
Lockable Parameters
User-Defined Functions
Data Manipulation
Delete Data
Exclude Data
DISPLAYS
Virtual Oscilloscope Display
Fast Fourier Transform
Automatic video synching
Re-title displays.
X-Y GRAPH
QuickCalc
Smooth in place
Zooming with the scroll wheel
Snap to origin when panning.
Click/Touch & drag panning
Select measurements from graph labels
Multiple y-axis measurements
Manage y axes
Prediction Tool
Copy a portion of a plot.
Translucent data values
Preview Data in Keep Mode
TABLE
Index column
Support for Text Entry
Out-of-order data entry
Non-numeric data entry
Automatic data type switching
PASCO Capstone
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Scrolling chart option
Delete selected data points.
Exclude selected data points.
Change unit directly in the display
Delta Tool
YES
YES
NO
NO
YES
YES
YES
YES
YES
(Coordinate Tool
Option)
YES
YES
YES
YES
YES
YES
YES
DataStudio
1.8.9r10
NO
YES
NO
YES
YES
NO
YES
YES
NO
YES
NO
NO
NO
YES
NO
YES
YES
NO
YES
YES
YES
(UNSMOOTH)
YES
NO
NO
YES
NO
YES
NO
NO
NO
NO
NO
SPARKvue 2.0
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
NO
YES
NO
YES
YES
YES
YES
YES
NO
012-14016A 156
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone
Specification
Cell insertion/deletion
Row insertion/deletion
Drag and Drop to Column
Reordering
Cut/Copy/Paste Values
Rename measurement directly
Change unit directly
Out-of-order Sampling
Selection Synchronized with other Displays
Insert/delete columns
Row Banding
SCOPE
Un-triggered Sampling
Trigger
Pre-trigger
Continuous Sampling
Sample Rate Control
Export Trace
Smart Cursor
Multiple Measurements
Multiple Axes
Trace Offset Controls
Compare Traces from the same sensor
Histogram
Count & bin measurement values
Side-by-Side Runs/Sets
Overlay Runs/Sets
Stack Runs/Sets
Autoscaling
Smart Cursor
PASCO Capstone
YES
NO
YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
850 only
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Statistics
Bar Graph
Display Values
Acquire Values Automatically
YES
NO
NO
DataStudio
1.8.9r10
NO
YES
NO
NO
NO
NO
NO
YES
NO
NO
YES
YES
NO
NO
NO
YES
YES
YES
NO
YES
NO
(Requires graph.)
YES
YES
YES
YES
YES
NO
(Does not snap to value.)
NO
NO
NO
SPARKvue 2.0
NO
NO
NO
NO
NO
(MULTIPLE
STEPS)
NO
NO
(MULTIPLE
STEPS)
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
012-14016A 157
Specification
Rename Bins
FFT
Automatic resolution adjustment
WORKBOOK
Universal Undo
Data Replay
Automatic hiding of tool bars option
Automatic rescaling of workbook
Reordering workbook pages
Live microscope/camera support
Automatic display fitting
Re-sizable displays
Auto-scaling Workbooks
Sensor-Independent Measurement ID
Drag and Drop Image Files
TEXT
Rich Text Tools
Subscript/Superscript Tools
PASCO Capstone
NO
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone
DataStudio
1.8.9r10
NO
SPARKvue 2.0
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO NO
Symbol insertion
Copy and paste rendered calculations from Microsoft Word.
Drag and drop rendered calculations from calculator
Bulleted list support
Video
Play pre-recorded video
Capture still images
Acquire and automaticallysync
Automatic playback option
Manually track objects
Automatically generate position, velocity and acceleration data from calibrated track
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
YES
NO
NO
NO
NO
NO
NO
(Movie Only)
NO
NO
NO
NO
NO
YES
NO
NO
YES
NO
NO
NO
NO
YES
Computer version:
NO
Pad version:
YES
NO
NO
NO
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
YES
NO
012-14016A 158
4 Frequently Asked Questions (FAQ)
FAQ... PASCO Capstone
Specification
PASCO Capstone points.
Measure lengths
Measure angles
Measure radii
JOURNAL
Snapshots
Reorder Pages
Annotate snapshots
Export as HTML
Print Journal
Function Generation
850 Universal Interface Support
PI-8127 Support
Peak Amplitude Sensor
Frequency Sensor
ScienceWorkshop 750 support
Sweep Frequency
Voltage Offset
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
850 only
850 only
YES
850 only
850 only
Generator output based on a measurement calculation
Peak Amplitude Virtual Sensor
Frequency Sensor
PROGRAM PREFERENCES
Adaptive Workbook Page
Shape
Custom default display font size.
Application preferences
HELP
YES (850 or 750)
YES
YES
YES
YES
YES
YES
DataStudio
1.8.9r10
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
NO
NO
On/Off only via outputswitch(x) function
NO
NO
NO
NO
YES
YES
SPARKvue 2.0
NO
NO
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
012-14016A 159
4 Frequently Asked Questions (FAQ)
FAQ... Installation and Updates
FAQ... Installation and Updates
"What licenses are required?": 160
"Is an MSI available for PASCO Capstone?": 160
"Do I need to update the interfaces?": 161
"Do I need to update the sensor datasheets?": 161
What licenses are required?
What licenses are available for PASCO Capstone?
l
Capstone Single User License (UI-5401) l
Capstone Site License (UI-5400)
Does the license expire?
No.
The license does not expire and entitles you to minor updates, such as the update from version 1.0 to 1.1.
Are upgrades free?
Yes, minor upgrades are free.
Minor upgrades and bug fixes for the licensed version of PASCO Capstone do not require additional purchase. They may be obtained by downloading the latest trial version from the PASCO scientific website. If the previous version of PASCO Capstone was licensed, the minor upgrade will accept the license key stored in your computer.
If you do not have a valid license key, the trial will expire in 60 days. A new license key may be purchased and entered from the About PASCO Capstone menu:
1. Click Help > About PASCO Capstone
2. Click Buy Key or Enter Key
Is an MSI available for PASCO Capstone?
An independent msi is not available for PASCO Capstone. The Capstone msi is wrapped by InstallShield*; parameters may be passed to the msi with command line switches. ( See
"How do I automate a network installation?": 66
) for information on passing parameters to the msi.
012-14016A 160
4 Frequently Asked Questions (FAQ)
FAQ... Installation and Updates
Do I need to update the interfaces?
PASCO Capstone will prompt to update the firmware if a new version exists. Follow the on-screen instructions.
However, you may encounter a problem with the interface requiring a manual firmware re-installation. ( See
"How do I force an update to an interface?": 66 )
Do I need to update the sensor datasheets?
No.
PASCO Capstone obtains default sensor information from a file that is installed and updated with Capstone.
(DataStudio and SPARKvue do obtain information from the sensors; however, PASCO
Capstone ignores any information from the sensor other than the ID.)
012-14016A 161
4 Frequently Asked Questions (FAQ)
FAQ... Setup
FAQ... Setup
"What do I need to have a complete measurement system? ": 162
"Can sensors sample at different rates?": 167
What do I need to have a complete measurement system?
Required Components
A complete measurement system consists of the following components:
Complete measurement system
The equipment required depends on the type of sensor used.
PASPORT Sensor Connections
PASPORT sensors have part numbers that are prefixed with PS-. These sensors feature auto identification, digital communication, and the ability to measure multiple quantities simultaneously (on some sensors).
Sensors connect as follows:
012-14016A 162
Sensor connections
4 Frequently Asked Questions (FAQ)
FAQ... Setup
ScienceWorkshop Sensor Connections
ScienceWorkshop sensors have part numbers that are prefixed with CI-.There are two classes of ScienceWorkshop sensors: analog and digital. The analog sensors may be identified by their round 8-pin DIN connectors. The digital sensors are identified by their
3.5 mm Tip-Ring-Sleeve (headphone) connectors.
These sensors connect as follows:
Analog sensor connections
012-14016A 163
Digital sensor connections
4 Frequently Asked Questions (FAQ)
FAQ... Setup
Can sensors sample at different rates?
Yes.
PASPORT sensors may have sampling rates different from the sampling rates of other PASPORT or ScienceWorkshop sensors.
Note: All ScienceWorkshop sensors sample at the same rate. PASPORT sensors can sample at different rates.
012-14016A 164
4 Frequently Asked Questions (FAQ)
FAQ... Data files
FAQ... Data files
"Where is my data saved?": 165
"What is the file export format?": 165
"What is the format for text import?": 166
Where is my data saved?
Recorded data is contained within the PASCO Capstone file (identified by the .cap
extension).
Note: Data is not permanently saved unless the Capstone file is saved or the data exported. If PASCO Capstone closes, without saving or exporting the data, all data will be lost.
What is the file export format?
PASCO Capstone exports data in tab or comma delimited files with the following information:
Run [ID]/Set [ID]
[Measurement] ([Unit])
Value
⁞
Value
Note: The precision of the exported data matches the numerical properties of the measurement. (
See "How do I change the numerical format of data?": 81 )
Example
Run #1 Run #1 Run #1 Run #2 Run #2 Run #2
Time (s) Force (N) Position (m) Time (s) Force (N) Position (m)
0.000
0.61
0.16
0.000
0.63
0.17
0.050
0.42
0.26
0.050
0.44
0.26
012-14016A 165
4 Frequently Asked Questions (FAQ)
FAQ... Data files
What is the format for text import?
Imported data are listed in the User-Entered Data Summary tab ( ) of Data
Summary.
The recommended format for file import is tab-delimited text with the measurement names and units on the first line:
⁞
MN
1
M
1
M
1
V
1
V
2
(u
1
) → MN
2
→ M
2
V
1
→ M
2
V
2
(u
2
) … → MN (u
→ … M n
V
1
→ … M n
V
2
[CR]
[CR] n
) [CR]
M
1
V m
→ M
2
V m
→ … M n
V m
[CR]
Where:
MN n
(u n
M n
V m
≡ measurement name of the n
≡ m
→ ≡ tab th value of the n th th measurement
) ≡ unit of measure of the nth measurement–leave off if no units measurement
[CR] ≡ carriage return
Note: PASCO Capstone may not recognize data that does not exactly fit the recommended file import format.
Example text file: animal
Peregrine Falcon
Golden Eagle
Gryfalcon family
Falco peregrines
Aquila chrysaetos
Falco rusicolus speed (km/h)
389
320
208
See
"How do I import data from Microsoft Excel*? ": 69
012-14016A 166
FAQ... Data and Measurements
FAQ... Data and Measurements
"Which data is recorded?": 167
"Can sensors sample at different rates?": 167
"What is Continuous Mode?": 168
"What is Fast Monitor Mode?": 169
"Is there a way to delete data points?": 170
"How are the curve fit and smoothing calculations determined?": 172
Which data is recorded?
PASCO Capstone records data for each available measurement (All data is recoded for immediate or future use in displays, calculations, and analysis.) and associated time data at the defined sample rate(s).
Sample Rate
Data appear on the sensor tab in the Data Summary tab ( ), and is selectable from any data display with a default name Run #%1, where %1 is an automatically generated run number.
See
"How do I record data in PASCO Capstone? ": 73
Can sensors sample at different rates?
Yes.
PASPORT sensors may have sampling rates different from the sampling rates of other PASPORT or ScienceWorkshop sensors.
Note: All ScienceWorkshop sensors sample at the same rate. PASPORT sensors can sample at different rates.
012-14016A 167
FAQ... Data and Measurements
What is Continuous Mode?
In this mode ( See
"How do I record data in PASCO Capstone? ": 73 ):
l
Data continuously records as soon as Record is pressed in the Controls
Palette.
Record button l
Data displays at the specified sampling rate(s) either until the hardware is no longer able to process the data (at which time data collection will stop with an error message) or until the Stop is pressed.
Maximum Frame Rate
The maximum frame rate
1 is directly related to the processing speed of the host and inversely related to the number of samples per frame: S
F
.
Where:
S
F
S
F
= R s
× T
≡ Samples per frame
R s
≡ Sampling rate (displayed in the Controls Palette)
T = time specified on the right of the plot area window
Automatic Sample Rate (R s
)
Select the auto-sample-rate-adjustment button to enable automatic sampling rate: l l
The sampling rate will increase when zooming into the time axis or when increasing the number of samples per frame by using the increase-samples-per-trace button .
The sampling rate will decrease when zooming out of the time axis or when decreasing the number of samples per frame by clicking the decrease-samplesper-trace button .
Manual Sample Rate (R s
)
Deselect the auto-sample-rate-adjustment button to disable automatic sampling rate:
1
The rate at which these frames of data are displayed.
012-14016A 168
l
The sampling rate is set in the Controls Palette.
Sample Rate
FAQ... Data and Measurements
What is Fast Monitor Mode?
In this mode ( See
"How do I record data in PASCO Capstone? ": 73 ):
l
The scope display behaves like a digital storage oscilloscope.
l
Data is manually recorded using Snapshot . ( See "How do I record data in PASCO Capstone? ": 73 )
Notes:
Only the data that is visible in the plot area is recorded as a run when Snapshot is clicked.
Recorded data appear on the sensor tab in the Data Summary tab ( ), and is selectable from any data display with a default name Monitor Run--
ScopeSnapshot%1 where %1 is an automatically generated run number. l
The scope will not drop samples within a frame due to an excessive sample rate.
l l
The trigger, by definition, occurs at a scope time of 0.00.
The scope displays complete frames of data. (The maximum frame rate
1
, depends on the processing speed of the host computer.)
Maximum Frame Rate
The maximum frame rate
2 is directly related to the processing speed of the host and inversely related to the number of samples per frame: S
F
.
Where:
S
F
S
F
= R s
× T
≡ Samples per frame
R s
≡ Sampling rate (displayed in the Controls Palette)
T = time specified on the right of the plot area window
Automatic Sample Rate (R s
)
1
The rate at which these frames of data are displayed.
2
The rate at which these frames of data are displayed.
012-14016A 169
FAQ... Data and Measurements
Select the auto-sample-rate-adjustment button to enable automatic sampling rate: l l
The sampling rate will increase when zooming into the time axis or when increasing the number of samples per frame by using the increase-samples-per-trace button .
The sampling rate will decrease when zooming out of the time axis or when decreasing the number of samples per frame by clicking the decrease-samplesper-trace button .
Manual Sample Rate (R s
)
Deselect the auto-sample-rate-adjustment button to disable automatic sampling rate: l
The sampling rate is set in the Controls Palette.
Sample Rate
Is there a way to delete data points?
Yes.
In PASCO Capstone version 1.1 or later, data points can be deleted or excluded.
l
Neither excluded nor deleted points are included in curve fits or statistical calculations.
l
If data points are excluded, they remain in the displays and are marked:
012-14016A 170
l with an X in the plot
Deleted and Excluded Data in a Plot
FAQ... Data and Measurements
Deleted data are removed.
Excluded data display with "X" marks.
l with a strike-through in the table
Deleted and Excluded Data in a Table
Deleted data are removed. Note the gap in time data.
Excluded data display with strikethrough.
l
If data points are deleted, they disappear from all of the displays. Either of these functions may be reversed with the undo button.
See
"How do I exclude, delete, and restore selected data?": 84
012-14016A 171
FAQ... Data and Measurements
Note: Deleted data are removed from the data set and the data cannot be restored at a later time. You can immediately undo a delete action by clicking Undo .
Note: Excluded data are masked in the data set and are not used by Capstone for data operations including display and calculations. Excluded data can be restored at any time.
Which data is active?
By default, the last selected measurement of the last data run is the active data for statistics and other actions.
See
"How do I select active data?": 111
How are the curve fit and smoothing calculations determined?
How are the errors in the parameters of the linear curve fits calculated?
The linear model error estimations were derived assuming that there is no error in the reported measurements and tends to underestimate the actual error in the parameters.
The errors are calculated as follows:
∆ m = σ
N
∆ b σ Σ
x i
2
∆
Where: m ≡ slope b ≡ intercept
N ≡ number of values (x i
...and...
, y i
)
σ ≡
Σ ( y i b mx i
)
2
N − 2
∆ ≡ N × Σ
( ) x i
2
What is the algorithm used by the graph smoothing tool?
The graph smoothing tool uses a center-weighted Savitzky–Golay smoothing algorithm of degree 4. The the value displayed in the Data Smoothing Slider n is an odd value
012-14016A 172
FAQ... Data and Measurements representing the total number of values in the original data set that are used in determining each smoothed value.
Data Smoothing Slider
Slider
n (used in the Savitzky–Golay smoothing algorithm)
Coefficient weights are used, such that the values closest to the value being smoothed usually have a greater weight, and thus a greater influence on the determining the resulting smoothed value. These coefficients are symmetric unless there are fewer than
n − 1 unsmoothed values to both sides of the smoothed value.
2
012-14016A 173
FAQ... Calculations and Calibration
FAQ... Calculations and Calibration
"What is the format for calculations?": 174
"What are the equations for calibration?": 174
"Can multiple measurements be calibrated simultaneously?": 175
What is the format for calculations?
Calculations have the format:
(variable name) = (valid functional expression)
The variable name may contain symbols, common subscripts and superscripts, and spaces.
If you enter a functional expression without (variable name) = , Capstone adds a generic name and "=". For example: Calc1= for variables and Constant1= for constants.
Calculations that involve only constants are immediately evaluated in the user-entry
Examples
Constant1=2*3
Calc1=[Acceleration(m/s²)]^2
Γ^2=sin([Angle(rad)])
Φ=integral([Force(N)],[Time(s)])
Resultant Acceleration=sqrt(([Acceleration- x(m/s²)]^2+[Acceleration- y(m/s²)]^2+[Acceleration- z(m/s²)]^2))
What are the equations for calibration?
The actual value, y(x) is calculated using measured value x and the calibration points
(x i
,y i
), where x i value: is the i th measured value and y i is the corresponding actual (standard)
012-14016A 174
FAQ... Calculations and Calibration
1 Point Offset y
1 x x
Examples: used internally by the force sensors, accelerometers
1 Point Slope
y
1 x
1
x
Examples: dissolved oxygen, type-K temperature, conductivity, drop counter
2 Point Linear
y
2
− y
1 x
2
− x
1
x + x y − y x x
2
− x
1
Examples: pH and other ion selective electrodes
Can multiple measurements be calibrated simultaneously?
Yes.
You may calibrate multiple measurements simultaneously if they are of the same type and exposed simultaneously to the same standards when performing the calibration.
Note: Simultaneous calibration is not recommended for pH, ISE, ORP, Conductivity, stainless-steel temperature sensors without insulating sleeves, or Disolved Oxygen sensors because these sensors will not read correctly if the probes are placed in the same solution simultaneously.
See
"How do I calibrate a sensor?": 94
012-14016A 175
FAQ... Displays
"What is panning and scaling?": 176
"Why are the display toolbars not active?": 177
What is panning and scaling?
Panning and Scaling
FAQ... Displays
PASCO Capstone supports several panning and scaling methods: l user (manual) Scaling
1 and Panning
2 l scaling based on maintaining the visibility or new data l scaling and panning the data to maximize the visibility of existing data
See
"How do I pan and scale?": 110 .
What is Panning Moving the origin within the display. Scale does not change.
Panning is the process of changing the value of the constant P in the Scaling and Panning Equation.
1
Changing the axis scale (value between tick marks) to zoom-in or zoom-out. Origin does not change.
2
Moving the origin within the display. Scale does not change.
012-14016A 176
FAQ... Displays
What is Scaling Changing the axis scale (value between tick marks) to zoom-in or zoom-out. Origin does not change.
Scaling is the process of changing the value of S in the Scaling and Panning Equation.
The process of increasing the value of the scaling factor S, is said to be zooming in and decreasing the value of the scaling factor is said to be zooming out.
What is Zooming-in/out around a point Changing the scale and origin around a single point.
You can simultaneously scale and pan such that a point other that the origin (for example: (m
10
, m
2
) remains stationary in the plot area when scaling. This process is the equivalent of scaling by S and panning by m i0
× S for each coordinate.
Scaling and Panning Equation
x i
= ( m i
− m
i 0
) × S + P
Where: x i m i
≡ virtual value of the i
≡ the i th th coordinate within the plot area measurement value m i0
≡ the coordinate value of the scaling stationary point
S ≡ scaling factor
P ≡ panning factor
Why are the display toolbars not active?
Toolbars are only active when a single display is active, and will only apply to the active display.
For displays with multiple plots such as for Graph or FFT displays, the toolbar actions apply to the active plot within the display.
See
"How do I select active data?": 111
012-14016A 177
FAQ... Scope
FAQ... Scope
"What does the Single Shot button do?": 178
"What is pre-triggering in the scope?": 179
What is the scope?
The scope is designed to view high-frequency oscillating data or single high-speed events that the graph display may not be able to capture.
Maximum Sampling Rate: The maximum supported sampling rate is a function of the computer-sensor interface that is connected to the computer (for example: 850 Universal
Interface → 10 MHz, ScienceWorkshop 750 → 250 kHz).
Features
Continuous Mode and Fast Monitor
Mode
Single shot
Multiple triggers
Pre-trigger
Image freeze
See
"What is Continuous Mode?": 168
"What is Fast Monitor Mode?": 169
"What does the Single Shot button do?": 178
"How do I select the scope trigger?": 131
"How do I freeze and record the scope display?": 135
What does the Single Shot button do?
The Single Shot button is useful for fast, non-repetitive events, such as measuring the time between an impulsive sound and its echo to determine the speed of sound.
When the Single Shot button is depressed on the scope toolbar and Monitor is pressed on the Controls Palette, the scope displays one frame of scope data and then stops monitoring.
Scope toolbar: Single Shot button
012-14016A 178
FAQ... Scope
Monitor button
Note: If the trigger button in the scope toolbar is depressed, the display of data starts when the trigger condition is satisfied. If the trigger button is not depressed, the display of data starts immediately.
Note: Fast Monitor Mode is required for the Single Shot function.
Note: Single Shot is limited by the hardware buffer size of the interface (~ 2000 samples for the 750 interface and ~ 16000 sample for the 850 interface).
What is pre-triggering in the scope?
The 0.00 second measurement on the scope is referenced to the time of the scope triggering event. Recording and displaying data that happened before a triggering event is called pre-triggering.
Note: An 850 Universal Interface is required to use the pre-trigger functionality.
See
012-14016A 179
FAQ... Video and Text
FAQ... Video and Text
"What cameras and video formats are supported?": 180
"Why does the text color remain black after picking a color?": 180
What cameras and video formats are supported?
Supported cameras
l
PASCO Capstone supports the UVC (USB Video Class 1.1) standard. Cameras that support UVC do not require additional drivers.
l
UVC 1.1 cameras are recommended; however, some older cameras may work with Capstone with the drivers developed by the manufacturer.
See
"How do I troubleshot video problems?": 142
Supported video formats
l
PASCO Capstone will record and playback video recorded in Capstone without any supporting software.
l
Capstone requires the latest version of the Apple QuickTime* player to playback movies that were not recorded in Capstone. Once QuickTime is installed, Capstone can playback all movies with the mov file extensions and most movies with the mp4 or avi extensions.
Why does the text color remain black after picking a color?
PASCO Capstone uses the Hue-Saturation-Value (HSV) model to determine the color.
The default value of the color value (brightness) defaults to 0 and the color displays black.
To display the selected color: move the brightness slider for the desired brightness.
012-14016A 180
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project