EMX NIR-50 Operating Instructions Manual

Add to My manuals
8 Pages

advertisement

EMX NIR-50 Operating Instructions Manual | Manualzz

NIR-50

RETROREFLECTIVE PHOTOEYE

U L 3 25 N O N - C OM P L I A NT

4564 Johnston Parkway, Cleveland, Ohio 44128

P. 800 426 9912 F. 216 518 9884

Sales Inquiries: [email protected]

Technical Support: [email protected] www.emxinc.com

Contents

Cautions and Warnings

Product Overview

Specifications

Controls and Indicators

Connections

Troubleshooting

Installation

Ordering Information

NIR-50 Operating Instructions

Document no.

NIR-50 Instructions.doc

2

2

2

3

4

4

3

4

1

Cautions and Warnings

WARNING … Not to be used for Personnel Protection

Never use product as sensing devices for personnel protection. Doing so could cause serious injury or death. These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.

UL 325 Non-compliant.

Retroreflective photoeyes rely on a reflective surface (a reflector) for proper operation. In some cases a vehicle with reflective surface at a given distance can act as a reflector and allow the gate to close on a car.

EMX Industries Inc. assumes no responsibility in this case and all risk is on the installer, designer and user of the gate system with a retroreflective photoeye. In case such risk is not acceptable, EMX

Industries Inc. strongly recommends the use of a through beam type of photoeye.

Product Overview

Product may be used for activation of gates or doors when the beam is interrupted. The NIR-50 failsafe reflective sensor uses an infrared signal that is returned from a reflector mounted on the opposite side of the opening to be monitored.

Specifications

Power Supply

Power Supply Tolerance

Current Draw

Housing Material

Relay Type

Temperature Range

Connector

Environmental Protection

Size

Response time

Range

Certifications

Specifications

12 – 240VDC / 24 – 240VAC

+ / - 10%

28mA standby 15mA detected @ 12 VDC

ABS and Acrylate on lenses

SPDT 2A @ 24 VDC 0.6A @ 220 VAC

-20º - +60ºC

Cable 2 Meters (6feet)

IP 66 IEC

1.6” x 2.6” x 0.8”

10ms maximum

0.3 – 30 feet

CE

NIR-50 Operating Instructions

Document no.

NIR-50 Instructions.doc

2

Controls and Indicators

Sensitivity

Clockwise increases sensitivity

Normally set to maximum (single turn)

Yellow LED

LED is on when unit is energized and signal is stable

Red LED

Is on when is energized and alignment is correct

LED is off when unit is energized and object is detected or not aligned

Connections

Wire Color Connection

Brown Power Positive (+)

Blue

Black

Gray

Power Negative (-)

Internal Relay Contact Normally Closed (NC)

Internal Relay Contact Normally Open (NO)

White Internal Relay Contact Common (COM)

NIR-50 Operating Instructions

Document no.

NIR-50 Instructions.doc

3

Troubleshooting

Symptom Possible cause

Units stays in detect Unit out of alignment

Reflector covered with dirt, dust, snow, or water

Water inside of reflector

Solution

Verify alignment

Clean reflector surface of contaminants

Replace reflector

Add Reflector 0-HD

No Output

No Detection

No power

Bad Connection, wires broken

Mis-wired

Unit not powered

Other reflective surface causing signal return

Check wiring as per chart on page 2

Check connections

Verify wired to correct inputs on operator

Check Power

Check surrounding area for reflective surface

Installation

Recommended alignment technique is to mount the NIR-50 at the desired location and hold reflector about 2 or 3 feet in front of the unit and while watching the lights to assure that both remain lit, move backward to the desired mounting location for the reflector. You may have to move the reflector up, down, left or right to keep the reflector in the middle of the signal path. This assures the least troublesome set up by keeping the reflector off the edges of the signal where any movement may take it out of alignment. Note: the signal pattern is only 2 feet diameter.

Ordering Information

NIR-50

NIR-HD

Reflector -O

Reflector-O-HD

Retroreflective photoeye, includes mounting bracket with hardware

Steel protective hood

Plastic reflector, 3" dia.

Plastic hood for reflector

NIR-50 Operating Instructions

Document no.

NIR-50 Instructions.doc

4

Accessories

NIR-HD Reflector-O Reflector-O-HD

Warranty

EMX Industries Incorporated warrants all products to be free of defects in materials and workmanship for a period of two years under normal use and service from the date of sale to our customer. This warranty does not cover normal wear and tear, abuse, misuse, overloading, altered products, damage caused by incorrect connections, lightning damage, or use other than intended design.

There is no warranty of merchantability. There are no warranties expressed or implied or any affirmation of fact or representation except as set forth herein.

EMX Industries Inc. sole responsibility and liability, and the purchaser’s exclusive remedy shall be limited to the repair or replacement at EMX

Industries option of a part or parts found not conforming to the warranty. In no event shall EMX Industries Inc. be liable for damages, including but not limited to damages resulting from non-conformity, defect in material or workmanship.

Effective date: January 1 st , 2002

NIR-50 Operating Instructions

Document no.

NIR-50 Instructions.doc

5

BLANK PAGE

NIR-50 Operating Instructions

Document no.

NIR-50 Instructions.doc

6

4564 Johnston Parkway

Cleveland, Ohio 44128

United States of America www.emxinc.com

Technical Support: (216) 834-0761 [email protected]

Sales: (216) 518-9888

Fax: (216) 518-9884 [email protected]

Revision 1.5

6.15.2018

NIR-50 Operating Instructions

Document no.

NIR-50 Instructions.doc

7

advertisement

Related manuals

advertisement