multimess User manual Technical parameters 1D4


Add to my manuals
36 Pages

advertisement

multimess User manual Technical parameters 1D4 | Manualzz

multimess

User manual

Technical parameters

Energy measuring device

1D4

System

I

English

Your partner for network analysis

2

© KBR Kompensationsanlagenbau GmbH

Subject to technical changes

Introduction

V1.00

KBR multimess 1D4

Introduction .............................................................................................................. 5

User manual ...............................................................................................................5

Intended use ..............................................................................................................5

Explanation of safety relevant symbols ......................................................... 6

Safety notes ................................................................................................................7

Product liability ........................................................................................................ 8

Disposal ...................................................................................................................... 8

Range of functions ..................................................................................................9

multimess 1D4-BS with multimess 1F96-DS ..................................................9

multimess 1D4-BS with multisio 6D6 and multisio 6F96-DS ....................................................................................................10

multimess 1D4-BS with multisys 3D2-ESBS ..................................................10

Device overview ....................................................................................................11

Installation ................................................................................................................14

Device assembly ....................................................................................................14

Connections .............................................................................................................15

Start-up ......................................................................................................................16

Start-up of the multimess 1D4 with multimess 1F96-DS display.................................................................................16

Start-up of the multimess 1D4 at the multisio 6D6 with multisio 6F96-DS ...............................................................19

Start-up of the multimess 1D4 with multisys 3D2-ESBS .................................................................................................20

System operation ..................................................................................................20

Configuration of system parameters in the Extras menu ................................................................................................20

Commi function .....................................................................................................22

Para function .......................................................................................................... 22

Consumption monitoring ..................................................................................22

Menu overview ...................................................................................................... 24

Technical data of the measuring module ..................................................... 28

Measuring accuracy ..............................................................................................28

Measuring principle ............................................................................................. 28

Device memory ......................................................................................................29

Power supply ..........................................................................................................29

Hardware inputs and outputs ............................................................................29

Inputs ..........................................................................................................................29

Outputs .................................................................................................................... 29

Electrical connection.............................................................................................30

Mechanical data ......................................................................................................30

3

KBR multimess 1D4

Standards and miscellaneous ............................................................................31

Technical data of the measuring module ..................................................... 32

Power supply ..........................................................................................................32

Hardware inputs and outputs ............................................................................32

Electrical connection.............................................................................................32

Mechanical data ......................................................................................................32

Standards and miscellaneous ........................................................................... 33

Protective measures ..............................................................................................33

Overvoltage and lightning protection ...........................................................33

Index .......................................................................................................................... 34

4 V1.00

Introduction

1 Introduction

KBR multimess 1D4

Thank you for choosing this KBR quality product. In order to familiarize yourself with the operation and configuration of the device, we recommend that you read this manual thoroughly, so that you are able to make use of the entire range of functions of this high-quality product.

1.1 User manual

The individual chapters serve to explain the technical details of the device and show how to avoid damage by means of proper installation and commissioning.

This user manual describes the multimess 1D4 device version with multimess 1F96-DS display. For other device versions, e.g. for multimess 1D4 on multisio 6D6 with multisio 6F96-DS or

multimess 1D4 with multisys 3D2-ESBS, please read the respective device manual.

This user manual is included in the scope of delivery of the device and must be accessible for the user at all times (e.g. in the switchgear cabinet). Even when the device is resold to third parties, the manual remains part of the device.

1.2 Intended use

Although we used the utmost care in assembling this user manual, we would like to thank you in advance for notifying us about any errors or ambiguous descriptions you might notice.

This device is intended for measuring electrical parameters via external transformers in the low-voltage network (400VAC Ph-Ph).

V1.00

5

6

KBR multimess 1D4 Introduction

1.3 Explanation of safety relevant symbols

This user manual contains notes that must be observed for your personal safety and to avoid damage to equipment.

These notes are identified by an i

or information symbol, depending on the degree of hazard they represent.

j

Warning

"Warning" means that death, major injuries or damage may occur in case the appropriate safety measures are not taken.

h

Caution

"Caution" means that minor injuries or damage may occur in case the appropriate safety measures are not taken.

i

Note

"Note" is an important information on the product, its operation or the respective part of the user manual to which special reference is made.

Disclaimer

The content of this user manual has been carefully reviewed in terms of the hardware and software described. Certain deviations, however, cannot be excluded, and the manufacturer is not liable for complete conformity. The specifications made in this user manual are checked on a regular basis, necessary corrections will be included in the next revision.

V1.00

Introduction KBR multimess 1D4

1.4 Safety notes

In order to prevent operating errors, operation of this device is kept as simple as possible. This way, you will be able to quickly start working with the device.

 In your own interest, however, you should read the following safety notes carefully. During assembly, the applicable DIN / VDE regulations must be observed!

Power supply connection, setup and operation of the device must be performed by qualified personnel only. Qualified personnel in accordance with the safety notes in this user manual are persons authorized to set up, ground and mark devices, systems and circuits in accordance with the applicable standards and regulations.

To avoid fire and electrical shock, the device must not be exposed to rain or humidity!

Before connecting the device to the power supply, check whether the local power supply conditions comply with the specifications on the nameplate.

A faulty connection can lead to the destruction of the device!

When connecting the device, observe the connection chart (see chapter “Connection chart”) and make sure that no voltage is applied to the connection lines. Only use proper wiring material and observe the correct polarity when wiring!

In order to ensure proper and safe operation of the product, it must be transported, stored, installed and assembled in accordance with the specifications and operated and maintained carefully.

A visibly damaged device must generally be considered unfit for use and disconnected from the power supply!

Error detection, repair and maintenance work may only be carried out in our facilities or after contacting the service team.

Unauthorized opening of the device voids any warranty. Correct operation can no longer be guaranteed!

 Opening the device may expose live parts. Capacitors in the device may still be loaded, even if the device has been disconnected from all voltage sources. It is generally not allowed to operate an open device!

V1.00

7

KBR multimess 1D4 Introduction

In systems susceptible to lightning, lightning protection must be provided for all input and output lines (for recommendations, see chapter “Protective measures”)!

1.5 Product liability

You have acquired a high quality product. In its manufacture, only components of the highest reliability and quality were used. Each device is subject to long-term testing before it is delivered. Regarding product liability, we refer to our general terms and conditions for electronic equipment, which you can find at www.kbr.de . The warranted characteristics of the device only apply for operation in accordance with its intended use!

1.6 Disposal

Defective, outdated or no longer used devices must be properly disposed of. At your request, we will dispose of the devices for you.

8 V1.00

Insert battery KBR multimess 1D4

2 Range of functions

multimess 1D4 is a multimeter for busbar mounting. On the output side, it can measure all typical alternating and direct current parameters of consumers.

The following device expansion stages are possible, featuring different ranges of function:

multimess 1D4-BS with multimess 1F96-DS” on page 9

multimess 1D4-BS with multisio 6D6 and multisio 6F96-DS” on page 10

multimess 1D4-BS with multisys 3D2-ESBS” on page 10

2.1 multimess 1D4-BS with multimess 1F96-DS

Connection of the optional multimess 1F96-DS display can be established with a ready-made RJ12 cable. For operation of the display, an additional power supply unit is needed, e. g. the multisys

1D4-PS-24V. This way, no complicated wiring of voltage and current paths from the converter to the switchgear cabinet door is necessary.

Up to 10 measuring modules can be read out and displayed.

Connection between the modules is also established via ready-made

RJ12 cables.

Power supply of the measuring device is provided by the measuring voltage. A separate control voltage is not necessary.

i

Note

multimess 1D4-BS with multimess 1F96-DS is the version described in this user manual.

V1.00

9

KBR multimess 1D4

2.2 multimess 1D4-BS with multisio 6D6 and multisio 6F96-DS

If the multimess 1D4 is connected to the multisio 6D6 instead of to the display, the multisio 6D6 creates a load profile memory (P+ P-/ Q+

Q-) and an eBus interface. Five measuring modules can be connected to each central storage module Connection between the modules is established via ready-made RJ12 cables.

2.3 multimess 1D4-BS with multisys 3D2-ESBS

For direct connection of the multimess 1D4 to the KBR eBus, the

multisys 3D2-ESBS gateway is required, which also provides the supply voltage for the module bus interface via ready-made RJ12 cables. A maximum of 15 measuring modules can be connected

(power consumption of the measuring module interface approx. 0.3

W, power output of the multisys 3D2-ESBS gateway approx. 5 W at 24

VDC). For a larger number of measuring modules, the multisys 1D4-PS-

24V power supply unit is required (power output 24 VDC, 10 W).

3 Device overview multimess 1D4 measuring module

For busbar assembly (7.5 mm rail)

Connection to measuring voltage Ph-N 230 VAC

Measuring current connection via transformer x/1A or x/5A

Plug terminal connection 2.5 mm 2

RJ12 display connection

RJ12 module bus connection for supply voltage of the bus interface / connection of additional measuring modules.

Recording of momentary current and voltage values.

Continuous energy meter for active and reactive energy

10 V1.00

multimess 1F96-DS

KBR multimess 1D4

Display illumination (Dot Matrix 128x96)

Brightness and contrast adjustable

Display dimming time adjustable

(energy saving function)

Operation via sensor buttons

Mounting depth 40 mm

Door assembly cut-out 92x92 mm

Module bus connection RJ12 for measuring modules and supply voltage

Display of momentary current and voltage values

Continuous energy meter for active and reactive energy

Management of up to 10 measuring modules

Assignment of station names to the measuring modules

Display language selectable

German ("deut") / English ("engl")

V1.00

11

KBR multimess 1D4

3.1 Operating structure

Instantaneous value display

The following overview gives you an idea of the multimess

1D4 operating structure with the

1F96-DS display. For a detailed description, please refer to

“Menu overview” on page 24.

U PH-N measuring module 1

Module name

Voltage channel 1

Voltage channel 2

Voltage channel 3

U PH-PH measuring module 1

Module name

Voltage channel 1

Voltage channel 2

Voltage channel 3

Apparent current meas. module 1

Module name

Apparent current channel 1

Apparent current channel 2

Apparent current channel 3

Total power

Module name

Apparent power

Active power

Reactive power

Apparent power meas. module 1

Module name

Apparent power channel 1

Apparent power channel 2

Apparent power channel 3

Additional measuring modules

Additional measuring modules

Additional measuring modules

Additional measuring modules

Additional measuring modules

12 V1.00

KBR multimess 1D4

Active power meas. module 1

Module name

Active power channel 1

Active power channel 2

Active power channel 3

Reactive power meas. module 1

Module name

Reactive power channel 1

Reactive power channel 2

Reactive power channel 3

Cosine Phi measuring module 1

Module name

Cosine Phi channel 1

Cosine Phi channel 2

Cosine Phi channel 3

Frequency

Module name

Network frequency

Energy meter:

Continuous counter

active energy

Continuous counter

reactive energy

Extras (Settings)

Display firmware version

Commissioning

Configuration

Additional measuring modules

Additional measuring modules

Additional measuring modules

Additional measuring modules

Additional measuring modules

Commissioning

Password

Module name

Scan / remove module

Reset display

Single-phase / 3-phase measurement

Transformer I 1 / 2

Transformer U 1 / 2

Configuration

Display firmware module

Measuring module selection

LCD contrast

LCD brightness

LCD dimmer brightness

Dimmer delay

Display test

Language selection

V1.00

13

KBR multimess 1D4

4 Installation

In this chapter, you will find a description of:

“Device assembly” on page 14

“Connections” on page 15

“Commissioning” on page 16

4.1 Device assembly

During installation, the applicable DIN / VDE regulations must be observed! Before connecting the device to the power supply, check whether the local power supply conditions comply with the specifications on the nameplate. A faulty connection may destroy the system! The device must be connected in accordance with the connection chart. For energy and synchronous pulse input, polarity must be observed (contact your energy supplier).

In systems susceptible to lightning, lightning protection must be provided for the control voltage, bus line and pulse lines (e.g. energy supplier pulse lines from the transformer station to the location of the energy control system).

14 V1.00

L1

L2

L3

N

V1.00

KBR multimess 1D4

4.2 Connections

Terminals 10 - 13

(L1, L2, L3, N)

Terminals 20 (k1) and 21 (l1), 22 (k2) and

23(l2), 24 (k3) and 25 (l3)

Measuring voltage. The power supply of the device is also provided by the measuring voltage. For technical data, please refer to the nameplate.

Measuring inputs for current. The measuring inputs for current must be connected via current transformers x/1A AC or x/5A AC. When connecting transformers, pay attention to the energy flow direction and the correct assignment of measuring voltage inputs to the current transformers.

13 12 11 10

N L3 L2

Measuring voltage

Messspannung

L1

Modul Modul k1

Measuring current l1

Messstrom k2 l2 k3 l3

20 21 22 23 24 25

Stromflussrichtung / current direction

15

Erstellung

Index Änderung

Maßstab: 1 : 1

Bezeichnung:

Artikelnr.:

Geprüft Datum

02.05.2011

EDV Bezeichnung:

Anschlussplan multimess 1D4-BS

02.05.11

Strasser

Datum Name

DTDASP0042_1811-1_multimess 1D4-BS.ai

A4

GmbH

Am Kiefernschlag 7

91126 Schwabach

Blatt

1 / 1

KBR multimess 1D4

4.3 Start-up

The following section describes the start-up procedure for the different device versions.

4.3.1 Start-up of the multimess 1D4 with multimess 1F96-DS display

For starting up the multimess 1D4 with multimess 1F96-DS display, please proceed as follows:

1. Connect the measuring module to the multimess 1F96-DS display via the module bus interface.

2. With the "Module out" connector, connect the measuring module to the multisys 1D4-PS-24V power supply unit via the second module bus interface.

3. At the multisys 1D4 power supply unit, connect the supply voltage

(refer to nameplate). The operation LED on the device is illuminated green.

4. At the terminals 10 (L1), 11 (L2), 12 (L3) and 13 (N), connect the measuring voltage (the operating voltage of the measuring module).

5. At the display, select the menu Extras > Commissioning to scan measuring modules connected.

6. Displayed are modules already existing, as well as the menu items

"scan" and "rem." (for removing measuring modules from the module bus list).

7. After selection of the menu item "scan", the scan mode is activated and the function LED at the measuring modules flashes slowly.

16 V1.00

KBR multimess 1D4

8. At the measuring module, the scan sensor button (close to the status LED, flashing green) is unlocked.

9. To set the measuring module into scan mode, touch the scan sensor button for about 4 seconds (the green status LED flashes more quickly)

10. The multimess display recognizes the measuring module and adds it to the list of modules connected.

11. You can now scan further modules, which are automatically added to the module list or, by touching the stop button, end the scanning process. The display can manage a maximum number of ten modules.

Set-up diagram for operation of the multimess 1D4 with multimess 1D4-DS (example):

LCD

V1.00

Measuring module 1 to 10 (maximum)

Modul in

Modul out

multisys 1D4-PS24V

+ _

101 102

L N PE

1 2 PE

24V DC

85 - 260V AC

Netz / Power multisys

1D4-PS-24V power supply unit

17

KBR multimess 1D4

Configuration

Extras menu

18

Display of the firmware version and release of the display

DS display

01.00 version

005 release

Previous menu

Display of measuring module version,

Display configuration

Start commissioning

Next menu

Display of the firmware version and release of the measuring module at the module bus

Measuring module designation

BS type module bus device

01.00 version

001 release

Selection of next measuring module

Selection of previous measuring module

Next menu

V1.00

KBR multimess 1D4

4.3.2 Start-up of the multimess 1D4 at the multisio 6D6 with multisio 6F96-DS

For starting up the multimess 1D4 at the multisio 6D6, please proceed as follows:

1. Connect the measuring module to the multisio 6D6 via the module bus interface.

2. At the terminals 10 (L1), 11 (L2), 12 (L3) and 13 (N), connect the measuring voltage (the operating voltage of the measuring module).

3. On the display, select the menu Settings > Module management.

4. Displayed are the multisio basic module as well as modules already existing and the menu item "scan".

5. After selecting this menu item with the cursor buttons, the scan mode can be started with the scan button and the scan display begins to flash. This way, the scan button at the measuring module

(close to the status LED, flashing green) is unlocked.

6. By pressing the scan sensor button for approx. 4 seconds, set the measuring module into scan mode (the green status LED flashes more quickly).

The multisio basic module now recognizes the measuring module and adds it to the list of modules connected.

You can now scan further modules, which are automatically added to the module list or, by touching the stop button, end the scanning process. The multisio 6D6 can manage a maximum number of ten modules.

You can now read out and process the data.

V1.00

19

KBR multimess 1D4

4.3.3 Start-up of the multimess 1D4 with multisys 3D2-ESBS

For starting up the multimess 1D4 at the KBR eBus via the multisys

3D2-ESBS gateway, please proceed as follows:

1. Connect the measuring module to the multisys 3D2 gateway via the module bus interface.

2. At the terminals 10 (L1), 11 (L2), 12 (L3) and 13 (N), connect the measuring voltage (the operating voltage of the measuring module).

3. Connect the multisys 3D2 gateway to the KBR eBus using terminals

90, 91 and 92.

A command, triggered by the visual energy computer software, unlocks the scan button at the measuring module (close to the status LED, flashing green).

4. By pressing the scan sensor button for approx. 4 seconds, set the measuring module into scan mode (the green status LED flashes more quickly).

The measuring module is detected and included in the bus list.

You can now read out and process the data.

5 System operation

In this chapter, you will find instructions on how to operate the multimess 1D4 with the multisio 1D4-DS display in daily use.

Furthermore, it contains references to the complete range of functions.

5.1 Configuration of system parameters in the Extras menu

To adapt multimess 1D4 to the system monitored, its parameters have to be configured.

Press the F1 key eleven times, selecting the Extras menu.

Here, measuring modules connected and the firmware version of the display are shown.

You have access to the following functions:

“Commi function” on page 22

“Para function” on page 22

The menu navigation of the multimess 1D4-DS is self-explanatory.

The operator is guided and supported by the device through operating instructions displayed for the respective situation.

20 V1.00

KBR multimess 1D4

The following signs and abbreviations will be used in the display:

Scroll forward (through main menu or submenu)

Scroll backwards (through main menu or submenu)







 





QS 

YS

O

SCAN

Return

Next measuring module

Previous measuring module

Value input

Select next screen

Return for configuration

Perform configuration

Fundamental power factor

Voltage phase / neutral conductor

Network frequency

Active power – total (3-phase)

Active power / reactive power / apparent power – total (3-phase)

Confirmation to save configuration

Discard configuration

Scan mode (search mode) for module search

imw Operating software of the measuring module or display module

1x3p 3-phase measurement

3x1p

 single-phase measurement

Measuring voltage transformer 1 / 2

Main current transformer 1 / 2 

LC

d

t

LCD parameter (display module)

Password protection

Reset function display

V1.00

21

KBR multimess 1D4

5.1.1 Commi function

With the "commi" start-up function, up to 10 measuring modules connected can be integrated.

This includes: Password protection for configuration

Assigning names to individual measuring modules

Scan menu for reading in measuring modules connected

Removing measuring modules connected

Selection of single-phase or 3-phase measurements

Configuration of current transformer primary / secondary

Configuration of voltage transformer primary / secondary

5.1.3 Para function

With the "para" configuration function, you can display the firmware version of the measuring modules connected, change the LCD settings and choose between English and German as the display language.

5.1.4 Consumption monitoring

In this operating mode, momentary measured values as well as continuous meters for active and reactive energy consumption can be read out directly at the display.

22 V1.00

V1.00

KBR multimess 1D4

The respective module name is included on each screen, depending on the measuring module selected.

The following momentary values can be displayed:

1 st

screen: Voltage Ph-N for phase L1, L2 and L3 individually

2 nd screen: Voltage Ph-Ph for phase L1-2,

L2-3 and L3-1 individually

3 rd screen: Apparent current for phase

L1, L2 and L3 individually

4 th

screen: Total power for apparent, active and reactive power

5 th screen: Apparent power for phase

L1, L2 and L3 individually

6 th

screen: Active power for phase

L1, L2 and L3 individually

7 th

screen: Reactive power for phase

L1, L2 and L3 individually

8 th screen: Cosine Phi for phase

L1, L2 and L3 individually

9 th screen: Power frequency

10 th screen: Continuous energy meter for active energy consumption

Continuous energy meter for reactive energy consumption

11 th screen: Commissioning

(Extras menu)

LCD parameters

23

KBR multimess 1D4

6 Menu overview

In this chapter, you will find a complete overview of all menus and menu items of the multimess.

24

Display of momentary measuring voltage for

Phase L1-N

Phase L2-N

Phase L3-N

Display of momentary measuring voltage for

Phase L1-2

Phase L2-3

Phase L3-1

V1.00

V1.00

KBR multimess 1D4

Display of momentary apparent current for

Phase L1

Phase L2

Phase L3

Display of total values of

Apparent power

Active power

Reactive power

Display of momentary apparent power for

Phase L1

Phase L2

Phase L3

25

KBR multimess 1D4

26

Display of momentary active power for

Phase L1

Phase L2

Phase L3

Display of momentary reactive power for

Phase L1

Phase L2

Phase L3

Display of momentary values of cosine Phi for

Phase L1

Phase L2

Phase L3

V1.00

V1.00

KBR multimess 1D4

Display of momentary network frequency

Display of the continuous energy meter for active energy (total value).

In the submenus

()

, the values of the individual phases can be seen.

Display of the continuous energy meter for reactive energy (total value).

In the submenus

()

, the values of the individual phases can be seen.

27

KBR multimess 1D4

Display of the firmware version of the display.

Furthermore, the Commissioning and

Configuration submenus are included.

7 Technical data

7.1 Technical data of the multimess 1D4 measuring module

7.1.1 Measuring accuracy

Current

Voltage

Apparent power

Active power

Reactive power

Frequency

± 0.5 % / ± 1 digit

± 0.5 % / ± 1 digit

± 1 % / ± 1 digit

± 1 % / ± 1 digit

± 1 % / ± 1 digit

± 0.1 Hz / ± 1 digit

7.1.2 Measuring principle

Reading

A/D converter

Measurement of U and I

Update speed

(complete measuring cycle)

Harmonics calculation

Frequency measurement

128 measured values per period

12 bit simultaneous recording of measured values for U and I;

< 1 sec.

DFT with 128 points over one period

Mode: Voltage measured between phase L1, L2, L3 – N

28 V1.00

KBR multimess 1D4

7.1.3 Device memory

Main and data memory

Program / parameter memory

Energy counter P+, P-, Q+, Q-

Limit violation Time for acquisition

16kB RAM unbuffered

256 kB Flash / 4kB EEP saved in EEP

8 min. for average current value, saved in RAM

7.1.4 Power supply

Measuring module power supply

Module bus power supply

50...230...280 VAC Ph-N, 3,2VA, provided by the measuring voltage ext. 24VDC, 0.3W, via RJ12 module bus connector

7.1.5 Hardware inputs and outputs

7.1.5.1 Inputs

Measuring inputs for voltage

Measuring inputs for current

U

L1-N

; U

L2-N

; U

L3-N

Input impedance

I

L1

; I

L2

; I

L3

Power consumption

7.1.5.2 Outputs

Serial interface

Module bus

Baud rate

Addressing

3 x 50V...230V...280V AC

900 kOhm each (Ph-N)

3 x 0,02A...5A...6A AC

<_ 0.3 VA per input at 6A

RS485 via RJ12 interface

38400

Can be addressed using the display or visual energy (connection via multisio

3D2 ESBS gateway)

V1.00

29

KBR multimess 1D4

7.1.6 Electrical connection

Connection elements

Permissible cross section of the connection lines

Measuring voltage inputs

Fuse protection

Measuring current inputs

Fuse protection

Input control voltage

Module bus connection

Connection material

Plug terminals

2.5 mm

2 max. 6 A

NONE!!! Always short-circuit current transformer terminals k and l prior to opening the circuit!

via measuring voltage ready-made KBR system cable (6 pole modular cable, unshielded), max. length 30m if placed accordingly

7.1.7 Mechanical data

Busbar devices

Housing measurements 90 x 71 x 61 mm (H x W x D)

Mounting type Wall mounting on DIN rail 7.5mm deep, in accordance with DIN EN 50022

Suitable for distribution board mounting

Weight approx. 175g

30 V1.00

KBR multimess 1D4

7.1.8 Standards and miscellaneous

Environmental conditions

Electrical safety

Standards and amendments

DIN EN 60721-3-3/A2: 1997; 3K5+3Z11;

(IEC721-3-3; 3K5+3Z11)

Operating temperature -5°C … +55°C

Humidity 5% … 95% non-condensing

Storage temperature

Standards and amendments

Protection class

Overvoltage category

Degree of protection

Electromagnetic compatibility

-25°C … +70°C

DIN EN 61010: 2001 +B1: 2002; +B2:

2004

II

CAT III: U

PH-PH

up to 400V

IP 20

DIN EN 60529:1991 +A1:2000

DIN EN 61000-6-1: 2007,

DIN EN 61000-6-2: 2005,

DIN EN 61000-6-3: 2007,

DIN EN 61000-6-4: 2007

V1.00

31

KBR multimess 1D4

7.2 Technical data of the multimess 1D4-DS display

7.2.1 Power supply

Power supply ext. 24VDC, 1W, via RJ12 module bus connector

7.2.2 Hardware inputs and outputs

Serial interface

Module bus

Baud rate

RS485 via RJ12 interface

38400

7.2.3 Electrical connection

Module bus connection

Connection material ready-made KBR system cable (6 pole modular cable, unshielded), max. length 30m if placed accordingly

7.2.4 Mechanical data

Flush-mounted device

Housing dimensions

Mounting cutout

Protection type

Weight

96 x 96 x 46 mm (H x W x D)

92 x 92 mm (according to manufacturer’s specifications)

Front IP 51 approx. 175g

32 V1.00

KBR multimess 1D4

7.2.5 Standards and miscellaneous

Environmental conditions

Electrical safety

Standards and subsequent amendments

DIN EN 60721-3-3/A2: 1997; 3K5+3Z11;

(IEC721-3-3; 3K5+3Z11)

Operating temperature -5°C … +55°C

Humidity 5% … 95%, non-condensing

Storage temperature

Standards and subsequent amendments

Protection type

-25°C … +70°C

DIN EN 61010-1/A2: 1996-05;

(IEC1010-1/A2)

Electromagnetic compatibility

IP20 in accordance with DIN EN 40050 part 9: 1993-05

DIN EN 61000-6-3: 2005-06;

(IEC 61000-6-3)

DIN EN 61000-6-2: 2000-03;

(IEC 61000-6-2)

7.3 Protective measures

7.3.0.1 Overvoltage and lightning protection

It is recommended to install overvoltage protection measures to protect our high-quality devices from damage. We also recommend to protect control voltage inputs and pulse lines, if required.

V1.00

33

KBR multimess 1D4

8 Index

A

Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

C

Commissioning multimess 1D4 at the multisio 6D6 with multisio 6F96-DS . . . . . 19 multimess 1D4 with display multimess 1F96-DS . . . . . . . . . . . . . 16 multimess 1D4 with multisys 3D2-ESBS . . . . . . . . . . . . . . . . . . . . . 20

Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Consumption monitoring . . . . . . . . . . . . . . 22

F

Function

Commi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Para. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

I

Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

M

Measuring inputs for current . . . . . . . . . . . 15

Measuring voltage . . . . . . . . . . . . . . . . . . . . . 15

Menu overview. . . . . . . . . . . . . . . . . . . . . . . . . 24

D

Device overview . . . . . . . . . . . . . . . . . . . . . . . 10

Device versions multimess 1D4-BS with multimess 1F96-DS . . . . . . . . . . . . . . . . . . . . . 9 multimess 1D4-BS with multisio 6D6 and multisio 6F96-DS . . . . . 10 multimess 1D4-BS with multisys 3D2-ESBS . . . . . . . . . . . . . . . . . . . . . 10

Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

E

Explanation of safety relevant symbols . . 6

P

Programming . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Product liability . . . . . . . . . . . . . . . . . . . . . . . . . 8

Protective measures . . . . . . . . . . . . . . . . . . . 33

S

Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Set-up diagram multimess 1D4 with multimess 1D4-DS 17

T

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 28

Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

U

User manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

34 V1.00

KBR Kompensationsanlagenbau GmbH

Am Kiefernschlag 7

D-91126 Schwabach,

Germany

Phone +49 9122 6373 - 0

Fax +49 9122 6373 - 83

E-mail [email protected]

www.kbr.de