advertisement
KBR multimess 1D4
5.1.1 Commi function
With the "commi" start-up function, up to 10 measuring modules connected can be integrated.
This includes: Password protection for configuration
Assigning names to individual measuring modules
Scan menu for reading in measuring modules connected
Removing measuring modules connected
Selection of single-phase or 3-phase measurements
Configuration of current transformer primary / secondary
Configuration of voltage transformer primary / secondary
5.1.3 Para function
With the "para" configuration function, you can display the firmware version of the measuring modules connected, change the LCD settings and choose between English and German as the display language.
5.1.4 Consumption monitoring
In this operating mode, momentary measured values as well as continuous meters for active and reactive energy consumption can be read out directly at the display.
22 V1.00
V1.00
KBR multimess 1D4
The respective module name is included on each screen, depending on the measuring module selected.
The following momentary values can be displayed:
1 st
screen: Voltage Ph-N for phase L1, L2 and L3 individually
2 nd screen: Voltage Ph-Ph for phase L1-2,
L2-3 and L3-1 individually
3 rd screen: Apparent current for phase
L1, L2 and L3 individually
4 th
screen: Total power for apparent, active and reactive power
5 th screen: Apparent power for phase
L1, L2 and L3 individually
6 th
screen: Active power for phase
L1, L2 and L3 individually
7 th
screen: Reactive power for phase
L1, L2 and L3 individually
8 th screen: Cosine Phi for phase
L1, L2 and L3 individually
9 th screen: Power frequency
10 th screen: Continuous energy meter for active energy consumption
Continuous energy meter for reactive energy consumption
11 th screen: Commissioning
(Extras menu)
LCD parameters
23
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 Introduction
- 5 User manual
- 5 Intended use
- 6 Explanation of safety relevant symbols
- 7 Safety notes
- 8 Product liability
- 8 Disposal
- 9 Range of functions
- 9 multimess 1D4-BS with multimess 1F96-DS
- 10 multisio 6F96-DS
- 10 multimess 1D4-BS with multisys 3D2-ESBS
- 11 Device overview
- 14 Installation
- 14 Device assembly
- 15 Connections
- 16 Start-up
- 16 multimess 1F96-DS display
- 19 multisio 6D6 with multisio 6F96-DS
- 20 multisys 3D2-ESBS
- 20 System operation
- 20 in the Extras menu
- 22 Commi function
- 22 Para function
- 22 Consumption monitoring
- 24 Menu overview
- 28 Technical data of the measuring module
- 28 Measuring accuracy
- 28 Measuring principle
- 29 Device memory
- 29 Power supply
- 29 Hardware inputs and outputs
- 29 Inputs
- 29 Outputs
- 30 Electrical connection
- 30 Mechanical data
- 31 Standards and miscellaneous
- 32 Technical data of the measuring module
- 32 Power supply
- 32 Hardware inputs and outputs
- 32 Electrical connection
- 32 Mechanical data
- 33 Standards and miscellaneous
- 33 Protective measures
- 33 Overvoltage and lightning protection
- 34 Index