Instructions - Parts
Feed Pump Kits
309815S
EN
For supplying polyurethane materials from 55 gal. (200 liter) drums to Reactor™ proportioning systems.
For professional use only. Not for use explosive atmospheres.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
See page 2 for a list of feed pump kits.
246655 Feed Pump Package shown installed in Reactor proportioning system. Some parts shown are not included in kit.
TI7690A
2
Feed Pump Kits
Contents
Feed Pump Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Manual Conventions . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Husky 1050 Wall Mount . . . . . . . . . . . . . . . . . . . 8
Standard 2:1 Kit . . . . . . . . . . . . . . . . . . . . . . . . . 8
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Changing Drums . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Complete Feed Pump Packages . . . . . . . . . . . . 10
Fluid Supply Kits . . . . . . . . . . . . . . . . . . . . . . . . 12
Pump Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
246419 Riser Tube Kit . . . . . . . . . . . . . . . . . . . . 15
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 16
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 16
Feed Pump Kits
Complete
Package
(fluid and air)
246369
246375
246376
246655
246081
247955
24Z987
Pump Kit
(1 pump and riser tube)
246366
246367
246368
246654
246898
247956
24Z988
25D295 25D296
Pump Model
Maximum Air Input
Pressure
Maximum Fluid Working
Pressure
Husky™ 515 100 psi (0.7 MPa, 7 bar)
Husky™ 716 100 psi (0.7 MPa, 7 bar)
100 psi (0.7 MPa, 7 bar)
100 psi (0.7 MPa, 7 bar)
Husky™ 1050 125 psi (0.86 MPa, 8.6 bar) 125 psi (0.86 MPa, 8.6 bar)
Triton™ 308 115 psi (0.8 MPa, 8 bar) 115 psi (0.8 MPa, 8 bar)
T2 2:1 Ratio
T1 2:1 Ratio
T3 3:1 Ratio
T3 CS 3:1
Ratio
180 psi (1.2 MPa, 12.5 bar)
180 psi (1.2 MPa, 12.5 bar)
405 psi (2.8 MPa, 28 bar)
360 psi (2.5 MPa, 25 bar)
100 psi (0.69 MPa, 6.9 bar) 315 psi (2.17 MPa, 21.7
bar)
100 psi (0.69 MPa, 6.9 bar) 315 psi (2.17 MPa, 21.7
bar)
309815S
Related Manuals
Related Manuals Manual Conventions
The following manuals are shipped with feed pump kits.
Refer to these manuals for detailed equipment information.
Feed Pumps
Part No.
308981
308981
312877
313435
309303
311882
312766
3A5180
Description
Husky 515 Pump
Husky 716 Pump
Husky 1050 Pump Operation
Husky 1050 Pump Repair-Parts
Triton 308 Pump
T2 2:1 Ratio Pump
T1 2:1 Ratio Pump
T3 3:1 Ratio Pump
The following manuals are shipped with Reactor
™
.
Refer to these manuals for detailed equipment information.
Reactor Electric Proportioner
Part No.
312065
312066
312062
312063
Description
Reactor Electric Proportioner,
Operation Manual (English)
Reactor Electric Proportioner,
Repair-Parts Manual (English)
Reactor Hydraulic Proportioner,
Operation Manual (English)
Reactor Hydraulic Proportioner,
Repair-Parts Manual (English)
The following manual is shipped with Fusion
™ spray gun. Refer to this manual for detailed equipment information.
Fusion Spray Gun
Part No.
309550
Description
Instruction Manual (English)
Warning
WARNING
A warning alerts you to possible serious injury or death if you do not follow instructions.
Symbols, such as fire, explosion, and electric shock
(shown), alert you to a specific hazard and direct you
to read the indicated hazard warnings on pages 4-4.
Caution
CAUTION
A caution alerts you to possible equipment damage or destruction if you do not follow instructions.
309815S 3
Warning
4
WARNING
FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD
Solvent and fumes in work area can ignite or explode. To help prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources, such as pilot lights, cigarettes and plastic drop cloths (potential static arc).
• Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
• Keep the work area free of debris, including solvent, rags, and gasoline.
•
Ground equipment and conductive objects. See Ground system., page 7.
• Hold gun firmly to side of grounded pail when triggering into pail.
• Use only grounded hoses.
• If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
• To avoid chemical reaction and explosion, do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment.
EQUIPMENT MISUSE HAZARD
Misuse can cause serious injury or death.
• For professional use only.
• Use equipment only for its intended purpose. Call your Graco distributor for information.
• Read manuals, warnings, tags, and labels before operating equipment. Follow instructions.
• Check equipment daily. Repair or replace worn or damaged parts immediately.
• Do not alter or modify equipment. Use only Graco parts and accessories.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not use hoses to pull equipment.
• Comply with all applicable safety regulations.
BURN HAZARD
This equipment is used with heated fluid, which can cause equipment surfaces to become very hot. To avoid severe burns:
• Do not touch hot fluid or equipment.
• Allow equipment to cool completely before touching it.
• Wear gloves if fluid temperature exceeds 110°F (43°C).
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
• Read Material Safety Data Sheet (MSDS) to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
You must wear proper protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury; inhalation of toxic fumes; and hearing loss. This equipment includes but is not limited to:
• Protective eyewear.
• Gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer.
• Hearing protection.
309815S
Installation
Installation
NOTE: For Husky 1050 Wall Mount Kit 246368, see
NOTE: For Standard 2:1 Kit 246081, see page 8.
1.
Flush pumps before using.
NOTE: Feed pumps are tested with oil. Flush out oil with a compatible solvent before spraying. See Flushing in
Reactor operation manual.
4.
Install pump kit (101).
a.
Inspect bung o-ring (309) and gasket (303) in place. If either is worn or damaged, or if ISO shows signs of crystallization, replace. See
b.
Remove elbow and 2 in. bushing supplied with desiccant dryer (6). Screw dryer 3/4 npt fitting into vent of A component (ISO) drum.
WARNING
Read warnings, page 4. Flush equipment only in a
well-ventilated area. Do not spray flammable fluids. Do not turn on heaters while flushing with flammable solvents.
2.
Keep A and B components separate
CAUTION
Lubricate bung o-ring (309) with 217374 ISO Pump
Oil each time you change drums. This keeps air and moisture from reacting with isocyanate and allows bung adapter to rotate freely.
c.
Open drum bung hole.
CAUTION
To prevent cross-contamination of fluid, mark A component (ISO) pumps, hoses, and connections with red tape. Mark B component (RES) pumps, hoses, and connections with blue tape. Do not interchange or cross-connect A component and B component parts.
3.
Position drums. Place A (ISO) and component B
(RES) drums as desired. Air hose (C) connecting
feed pumps is 15 ft (4.57 m) long. See F IG . 1.
CAUTION
Tighten pump clamps and external fasteners before first use. See pump manual.
d.
Place riser tube into drum. Tighten bung adapter (304) securely.
309815S 5
Installation
246655 Package shown installed in Reactor proportioning system.
Includes * parts only.
103* 102*
NOTE: System shown includes 246978 Circulation
Kit, available separately, which includes two 247616 desiccant dryers (6).
101* (ISO)
304*
2
C*
*103
2
2*
6*
*102
2 Air Supply Kit. See 309827.
2
*2
*103 (Ref)
*101 (RES)
103* (Ref)
D
2
2*
F IG . 1. Installation
TI7690A
6 309815S
Installation
5.
Connect fluid supply kit.
a.
Install swivel union (102) in pump fluid outlet.
Triton 308 only: Install 90° elbow (104) in pump outlet, then install swivel union (102) in elbow.
3 Used on Triton 308 packages only.
102 104 3
TI3513a b.
Connect hose (103) between swivel union (102)
and Reactor swivel inlet (D). See F IG . 1.
6.
Install air supply kit (2).
a.
Supply clean, dry, filtered air to feed pumps.
b.
See manual 309827 to install air supply kit.
7.
Ground system.
WARNING
a.
Feed pump: follow instructions in separate feed pump manual, supplied.
b.
Reactor: see Reactor operation manual.
c.
Spray gun: see gun manual.
d.
Fluid supply containers: follow your local code.
e.
Object being sprayed: follow your local code.
f.
Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity.
g. To maintain grounding continuity when flushing
or relieving pressure, hold a metal part of spray gun firmly to the side of a grounded metal pail, then trigger gun.
309815S 7
8
Installation
Husky 1050 Wall Mount
1.
Be sure wall can support weight of pump, hoses, and accessories, and can withstand stress during operation.
2.
Position wall bracket (204) no more than 5 ft (1.52
m) above floor. Check that bracket is level. Attach to wall, using screws long enough to keep bracket from
3.
Connect swivel union (205) to pump inlet.
4.
Install bushing (3) in pump air inlet.
5.
Install pump (201) on bracket (204) securely, using provided dampeners, washers, and lock nuts.
6.
Connect elbow (206) to top of riser tube kit (202).
7.
Connect suction hose (203) to elbow (206) and inlet swivel (205).
8.
Follow steps 1-7, pages 5-7, to finish installation.
Standard 2:1 Kit
1.
2.
Open drum bung hole. Screw bung adapter with gasket into bung hole. See pump manual 311882.
3.
Install swivel fitting (1c) in pump fluid outlet. See
4.
Connect hose (1b) between swivel fitting (1c) and
Reactor swivel inlet (D, see F IG . 1).
5.
Remove elbow and 2 in. bushing supplied with des-
iccant dryer (6, see F IG . 1). Screw dryer 3/4 npt fit-
ting into vent of A component (ISO) drum.
6.
Follow steps 6-7, page 7, to finish installation.
1a
3
203
205
201
Bung adapter
1c
1b
206
202
F IG . 2. Husky 1050 Wall Mount
204
WLD
F IG . 3. Standard 2:1 Kit
TI10281a
309815S
Operation
Operation
Startup
1.
See Load fluid with feed pumps in Reactor operation manual.
2.
Open feed pump air regulator.
3.
Open feed pump bleed-type master air valve.
4.
Adjust air to feed pump with needle valve.
NOTE: Cold, viscous material may be difficult to prime.
Use needle valve to reduce air flow to motor.
NOTE: Do not plug or shut off pump fluid outlet when priming. Fluid must be free to flow through pump to prime.
NOTE: To increase pump flow rate and reduce icing, remove pump muffler. This will increase exhaust noise.
5.
Never let pump run when drum is empty. A dry pump can accelerate and damage itself. If pump is running too fast, stop it immediately. Check and refill fluid supply, or flush with compatible solvent. Always prime entire system to remove any air. Do not let material harden in pump.
Shutdown
See Shutdown and Pressure Relief Procedure in
Reactor manual. Close feed pump bleed-type master air valve.
Changing Drums
CAUTION
To prevent cross-contamination of fluid when changing drums, complete changing one component before changing second component.
1.
See Shutdown.
2.
Remove riser tube from drum. Install in new drum.
3.
Lubricate bung o-ring (309), page 5.
4.
See Load fluid with feed pumps in Reactor operation manual.
Maintenance
NOTE: See supplied pump manual for maintenance, repair, and parts information.
Lubricate bung o-ring (309) with 217374 ISO Pump Oil each time you change drums. This keeps air and moisture from reacting with ISO.
Whenever pump is removed from drum, inspect bung o-ring (309) and gasket (303) in place. If either is worn or damaged, or if ISO shows signs of crystallization,
Tighten pump clamps and external fasteners periodically. See pump manual.
309815S 9
Parts
Parts
Complete Feed Pump Packages
Part No. 246369, Husky 515 Package
Part No. 246375, Husky 716 Package
Part No. 246376, Husky 1050 Package
Part No. 246655, Triton 308 Package
(shown)
Ref.
No. Part No. Description
1 246481 FLUID SUPPLY KIT, Husky 515
246482 FLUID SUPPLY KIT, Husky 716
246676 FLUID SUPPLY KIT, Husky 1050
246677 FLUID SUPPLY KIT, Triton 308
2 246483 AIR SUPPLY KIT; see 309827
3 100206 BUSHING, air inlet; 1/2 npt(m) x 1/4
npt(f); 246376 only; see page 14 for
location
6 247616 KIT, desiccant dryer; for ISO side
7 104969 BUSHING, reducer; 1/2npt(m) x 3/4 npt(f); use on 1/2 in. ISO inlet hose
(not shown)
Qty
1
1
1
1
1
2
1
1
246655 Package shown installed in Reactor proportioning system.
Includes * parts only.
1* (ISO)
1
6* (ISO)
1
1* (RES)
2
2*
NOTE: System shown includes 246978 Circulation
Kit, available separately, which includes two 247616 desiccant dryers (6).
1* (Ref)
2
2*
1* (Ref)
1
Fluid Supply Kit. See page 12.
2 Air Supply Kit. See 309827.
TI7690A
309815S 10
2*
2
Parts
Part No. 246081, T2 2:1 Package
Ref.
No.
Part No. Description
1 246898 KIT, fluid supply
1a 295616 PUMP, 2:1; see 311882
1b 217382 HOSE, fluid; 3/4 npt (mbe); 3/4 in.
(19 mm) ID; 10 ft (3.05 m); nylon
1c 157785 FITTING, swivel; 3/4 npt(m) x 3/4 nps(f)
1d 113344 FITTING, swivel; 1/2 npt(m) x 3/4 nps(f); (not shown) (use as
2
6 necessary to adapt 1/2 npt ISO inlet)
246483 AIR SUPPLY KIT; see page 10 and
309827
247616 KIT, desiccant dryer; for ISO side;
Qty
1
2
2
2
1
1
1
Part No. 247955, T1 2:1 Package
Ref.
No.
Part No. Description
1 247956 KIT, fluid supply
1a 256200 PUMP, 2:1; see 312766
1b 217382 HOSE, fluid; 3/4 npt (mbe); 3/4 in.
(19 mm) ID; 10 ft (3.05 m); nylon
1c* 113344 FITTING, swivel; 1/2 npt(m) x 3/4 nps(f)
1d 113344 FITTING, swivel; 1/2 npt(m) x 3/4 nps(f); (not shown) (use as
2
6 necessary to adapt 1/2 npt ISO inlet)
246483 AIR SUPPLY KIT; see page 10 and
309827
247616 KIT, desiccant dryer; for ISO side;
Qty
1
2
2
3
1
1
1
*Use additional 1/2 NPT x 3/4 NPSF fitting to adapt to
1/2 NPT inlet if necessary.
Part No. 24Z987, SS T3 3:1 Package
Ref.
No.
Part No. Description
26A304 PUMP, transfer, 3:1, T3
246483 KIT, supply, air (feed pump, gun)
217382 HOSE, coupled, 10 ft
127785 COUPLING, universal, 1 in. nptf
247616 KIT, accessory, desiccant dryer
157785 FITTING, swivel
Part No. 25D295, CS T3 3:1 Package
Ref.
No.
Part No. Description
24Z834 PUMP, T3, CS
217382 HOSE, coupled, 10 ft
157785 FITTING, swivel
127785 COUPLING, universal, 1 in. nptf
246483 KIT, supply, air (feed pump, gun)
Qty
2
2
2
2
1
Qty
2
2
2
1
1
2
1a
1c
1b
Shown: T2
TI10282a
309815S 11
Parts
Fluid Supply Kits
Part No. 246481, Husky 515 Kit
Part No. 246482, Husky 716 Kit
Part No. 246676, Husky 1050 Kit
Part No. 246677, Triton 308 Kit (shown)
Ref.
No.
Part No. Description
101 246366 PUMP KIT, Husky 515; 246481
246367 PUMP KIT, Husky 716; 246482
246368 PUMP KIT, Husky 1050; 246676
246654 PUMP KIT, Triton 308; 246677
102 157785 UNION, swivel; 3/4 npt(m) x 3/4 npsm(f); 246481 and 246482
202965 UNION, swivel; 1 in. npt(m) x 3/4 npsm(f); 246676
113344 UNION, swivel; 1/2 npt(m) x 3/4 npsm(f); 246677
103 217382 HOSE, fluid; 3/4 npt (mbe); 3/4 in.
(19 mm) ID; 10 ft (3.05 m); nylon
104 217430 ELBOW, swivel; 90°; 3/8 npt(m) x
1/2 npsm(f); 246677 only
105 104969 BUSHING, reducer, 1/2 npt(m) x
3/4 npt(f); use on 1/2 npt ISO inlet hose (not shown)
Qty
2
2
2
2
2
2
2
2
2
1
103
1 Used on 246677 only.
102
104
1
101
TI3449a
12 309815S
Parts
Pump Kits
Part No. 246366, Husky 515 Pump Part No. 246367, Husky 716 Pump
Ref.
No.
201 246484 PUMP, Husky 515; see 308981
202
Part No. Description and read CAUTION below
246419 RISER TUBE KIT; see page 15
CAUTION
246484 Husky 515 Pump is built specifically for use with isocyanates and is tested with oil. To order replacement parts and repair kits, refer to the Husky
515 parts list in manual 308981.
Qty
1
1
Ref.
No.
Part No. Description
201 246485 PUMP, Husky 716; see 308981 and read CAUTION below
202
246419 RISER TUBE KIT; see page 15
203 158555 NIPPLE, reducing; 1 in. npt x 3/4 npt
Qty
1
1
1
CAUTION
246485 Husky 716 Pump is built specifically for use with isocyanates and is tested with oil. To order replacement parts and repair kits, refer to the Husky
716 parts list in manual 308981.
201
201
202 203
202
TI3450a
309815S 13
Parts
Part No. 246368, Husky 1050 Pump Part No. 246654, Triton 308 Pump
Ref.
No.
Part No. Description
201 647673 PUMP, Husky 1050; see 312877 and 313435, and read CAUTION below
202
246419 RISER TUBE KIT; see page 15
203 214961 HOSE, suction; 3/4 npt (mbe);
3/4 in. (19 mm) ID; 6 ft (1.8 m); neoprene
204 24C637 KIT, bracket, wall (includes mounting hardware)
205 202965 UNION, swivel, pump inlet;
1 in. npt(m) x 3/4 npsm(f)
206 107409 ELBOW, swivel, riser tube; 90°;
1 in. npt(m) x 3/4 npsm(f)
Qty
1
1
1
1
1
1
Ref.
No.
Part No. Description
201 233500 PUMP, Triton 308; see 309303
202
246419 RISER TUBE KIT; see page 15
203 158555 NIPPLE, reducing; 1 in. npt x 3/4 npt
Qty
1
1
1
201
203
CAUTION
647673 Husky 1050 Pump is built specifically for use with isocyanates and is tested with oil. To order replacement parts and repair kits, refer to the Husky
1050 parts list in manual 313435.
202
1
3
203
205
201
TI3447a
206
202
204
1
WLD
14 309815S
Technical Data
246419 Riser Tube Kit
Ref.
No.
Part No. Description
301 159101 HOUSING, valve, intake
302 156592 TUBE, riser
303 106537 GASKET, bung
304 15B728 ADAPTER, bung
305 15B727 FITTING; 1 in. npt
306 15B921 SPACER
307 100279 BALL
308 159100 RETAINER, ball
309 110831 O-RING
Qty
1
1
1
1
1
1
1
1
1
305
304
302
Technical Data
Category
Maximum air input pressure
Maximum fluid working pressure
Wetted parts
309815S
309
1
303
307
301
1 Lubricate with 217374 ISO Pump Oil each time you change drums.
308
306
TI3445a
Data
Husky 515: 100 psi (0.7 MPa, 7 bar)
Husky 716: 100 psi (0.7 MPa, 7 bar)
Husky 1050: 125 psi (0.86 MPa, 8.6 bar)
Triton 308: 115 psi (0.8 MPa, 8 bar)
T2 2:1 Ratio: 180 psi (1.2 MPa, 12.5 bar)
T1 2:1 Ratio: 180 psi (1.2 MPa, 12.5 bar)
Husky 515: 100 psi (0.7 MPa, 7 bar)
Husky 716: 100 psi (0.7 MPa, 7 bar)
Husky 1050: 125 psi (0.86 MPa, 8.6 bar)
Triton 308: 115 psi (0.8 MPa, 8 bar)
T2 2:1 Ratio: 405 psi (2.8 MPa, 28 bar)
T1 2:1 Ratio: 360 psi (2.5 MPa, 25 bar)
T3 3:1 Ratio: 315 psi (2.17 MPa, 21.7 bar)
Pump: see supplied pump manual
Riser tube: carbon steel
Fluid hoses: nylon
Suction hose (Husky 1050 only): neoprene
Fittings: carbon steel
15
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit
www.graco.com
.
For patent information, see
www.graco.com/patents .
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
2ULJLQDOLQVWUXFWLRQV This manual contains English. MM 309815
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2003, Graco Inc. is registered to ISO 9001 www.graco.com
Revision S, January 2018
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Feed Pump Kits
- 3 Related Manuals
- 3 Manual Conventions
- 5 Installation
- 8 Husky 1050 Wall Mount
- 8 Standard 2:1 Kit
- 9 Operation
- 9 Startup
- 9 Shutdown
- 9 Changing Drums
- 9 Maintenance
- 10 Parts
- 10 Complete Feed Pump Packages
- 12 Fluid Supply Kits
- 13 Pump Kits
- 15 246419 Riser Tube Kit
- 15 Technical Data
- 16 Graco Standard Warranty
- 16 Graco Information