Graco 309199A Magnum Function Test for Home Depot Owner's Manual

Add to my manuals
2 Pages

advertisement

Graco 309199A Magnum Function Test for Home Depot Owner's Manual | Manualzz

Airless Sprayers

Function Checklist for Customer Returns

To prevent injury and equipment damage, see all Warnings and Cautions in the Operating Instructions.

Fluid Injection Hazard

Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of injury from injection, always follow this Pressure Relief Procedure when you stop spraying and before service:

1.

Turn Power switch OFF.

2.

Place prime tube in waste pail.

3.

Turn Spray/Prime valve to PRIME (pointing down) to relieve pump pressure.

4.

Turn Pressure Control knob to the left (counterclockwise) to minimum pressure.

PRIME

Most M

AGNUM

customer returns are for priming or performance problems due to improper cleaning. Use this checklist to help identify if sprayer is functioning or needs to be sent in for service.

Before you test the sprayer:

1.

Inspect all fittings and hose and gun connections to make sure they are tight.

2.

Remove tip/guard assembly from spray gun.

Never leave water in sprayer. Sprayer must be stored with Pump Armor t

or mineral spirits.

If water coming out of sprayer is dirty, paint got left in the sprayer. Follow Step 1 procedure

(Power Flush t

Sprayer with Water) on back of this page, and let water run until clean.

Performance Problems

Many factors can contribute to performance problems, but most problems are caused by filters that have not been properly cleaned. Customer complaints for performance problems will be low fluid output or poor spray pattern.

Check Filters

A. InstaClean t

filter is clean.

B. Gun filter is clean.

C. Inlet strainer is clean.

InstaClean filter gun filter

(XR7 / XR9) gun filter

(XR5) inlet strainer

NEED HELP? Call us at 1-888-541-9788 or visit our website at www.graco.com

Priming Problems

1. Power Flush Sprayer with Water

A. Turn Spray/Prime valve to PRIME.

B. Separate prime tube (smaller) from suction tube (larger).

C. Unscrew inlet screen from suction tube.

D. Place prime tube in waste pail.

E. Screw Power Flush attachment (included with sprayer) onto garden hose, and open Power Flush attachment.

F. Screw garden hose and Power Flush attachment onto suction tube, and turn on garden hose.

G. Plug sprayer into grounded outlet, and turn power switch ON.

H. Turn Pressure Control knob to the right (clockwise) until pump starts.

Water flowing out of prime tube indicates pump is primed with water.

Power Flushing setup

Power Flush attachment garden hose

PRIME prime tube suction tube prime tube open suction tube closed

Power

Flush attachment

Power

Flush attachment garden hose

(turn on) garden hose

2. If Sprayer Does Not Prime

A Check if air bubbles are flowing out of submerged end of prime tube. If no bubbles, go to Step 3, Free Stuck Inlet Ball.

B. If bubbles are flowing out of prime tube, sprayer is pumping without priming.

Tighten suction tube nut at pump inlet, and tighten hose clamp that fastens suction tube.

– If bubbles stop and water comes out of prime tube, repeat Step 1, Power Flush Sprayer With Water.

– If still no flow of water from prime tube, go to Step 4, Check Inlet Valve Ball.

3. Free Stuck Inlet Ball (left dirty or in water)

Tap gently on inlet valve with wrench while pump is running.

This might loosen stuck inlet valve ball.

tap here

4. Check Inlet Valve Ball

A. Remove suction assembly and inlet valve from pump inlet.

B. Make sure ball in inlet valve body is loose. If ball is stuck on seat, tap it loose and thoroughly clean ball and seat. Reassemble valve and suction assembly, and repeat Step 1, Power Flush Sprayer With Water.

5. If Sprayer Still Does Not Prime

If sprayer does not prime after all of the above procedures, send it to a Graco/M

AGNUM

Authorized Service Center.

All written and visual data contained in this document reflect the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.

GRACO INC.

P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441

Graco Inc. is registered to I.S. EN ISO 9001

E

COPYRIGHT 2000, GRACO INC.

PRINTED IN USA 309199 Rev. A 09/2000 inlet valve suction assembly