Operation

Magnum M3+, M5+, L10+, and L30+

Airless Sprayer

332641B

EN

- For portable spray applications of architectural paints and coatings -

Models 16W106, 16W331, 16W332, 16W516

IMPORTANT SAFETY INSTRUCTIONS

Read all warnings and instructions in this manual.

Save these instructions.

See page 3 for model series information including

dispense rate, recommended hose length, guns, and maximum working pressure.

M3+, M5+, L10+ ONLY: Use water-based or mineral spirit-type materials only. Do not use materials having flash points lower than 100° F (38° C). This includes, but is not limited to, acetone, xylene, toluene, or naptha. For more information about your material, request MSDS from distributor or retailer.

Magnum M3+

Model: 16W106

Series A

Magnum M5+

Model: 16W331

Series A

ti22045a

Magnum L10+

Model: 16W332

Series A

ti11304b

Magnum L30+

Model: 16W516

Series A

ti22095a ti11305b

2

Table of Contents

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Component Identification M3+ and M5+ . . . . . . . . 8

Component Identification L10+ and L30+ . . . . . . 10

Component Identification L10+ and L30+ . . . . . . 11

Grounding and Electric Requirements . . . . . . . . 12

Thermal Overload . . . . . . . . . . . . . . . . . . . . . . . 12

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Trigger Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Pressure Relief Procedure . . . . . . . . . . . . . . . . 13

Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Prime and Flush Storage Fluid . . . . . . . . . . . . . 14

Install Tip and Guard on Gun . . . . . . . . . . . . . . 16

Spraying Techniques . . . . . . . . . . . . . . . . . . . . 17

Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . 17

Triggering Gun . . . . . . . . . . . . . . . . . . . . . . . . . 17

Aiming Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Unclogging Spray Tip . . . . . . . . . . . . . . . . . . . . 18

Choosing the Correct Tip . . . . . . . . . . . . . . . . . 19

Reversible Tip Selection Chart . . . . . . . . . . . . . 19

Shutdown and Cleaning . . . . . . . . . . . . . . . . . . . . 20

Pail Flushing . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Power Flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Cleaning InstaClean™ Fluid Filter (L30+ Only) . 24

Cleaning Gun . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Short Term Storage . . . . . . . . . . . . . . . . . . . . . 25

Long Term Storage . . . . . . . . . . . . . . . . . . . . . . 25

Maintenance and Service . . . . . . . . . . . . . . . . . . . 27

Caring for Sprayer . . . . . . . . . . . . . . . . . . . . . . . 27

Paint Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Pump Check Valves . . . . . . . . . . . . . . . . . . . . . 27

Pump Packings . . . . . . . . . . . . . . . . . . . . . . . . . 27

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 36

332641B

Specifications

Specifications

This equipment is not intended for use with flammable or combustible materials used in places such as cabinet shops or other “factory”, or fixed locations. If you intend to use this equipment in this type of application, you must comply with NFPA 33 and OSHA requirements for the use of flammable and combustible materials.

Model Name

Magnum M3+

Magnum M5+

Series

A

A

Maximum

Dispense

Rate lpm

(gpm)

0.91 lpm

(0.24 gpm)

1.02 lpm

(0.27 gpm)

Hose Length and

Diameter

6.4 mm x 7.5 m

(1/4 in. x 25 ft)

6.4 mm x 7.5 m

(1/4 in. x 25 ft)

Gun

Model

SG2

SG3

Maximum Working bar

207

207

Pressure

MPa

21

21

PSI

3000

3000

Magnum L10+

Magnum L30+

A

A

1.17 lpm

(0.31 gpm)

1.44 lpm

(0.38 gpm)

6.4 mm x 15 m

(1/4 in. x 50 ft)

6.4 mm x 15 m

(1/4 in. x 50 ft)

SG3

SG3

207

207

21

21

3000

3000

332641B 3

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

GROUNDING

This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

• Improper installation of the grounding plug is able to result in a risk of electric shock.

• When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal.

• The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.

• Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded.

• Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician.

• This product is for use on a nominal 230V circuit and has a grounding plug similar to the plug illustrated in the figure below.

230V

4

• Only connect the product to an outlet having the same configuration as the plug.

• Do not use an adapter with this product.

Extension Cords:

• Use only an extension cord that has a grounding plug and a receptacle that accepts the plug on the product.

• Make sure your extension cord is not damaged. If an extension cord is necessary, use 12 AWG

(2.5 mm

2

) minimum to carry the current that the product draws.

• An undersized cord results in a drop in line voltage and loss of power and overheating.

332641B

332641B

Warnings

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

• Do not spray flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment. For M3+, M5+, and L10+ models: only use water-based or mineral spirit-type materials with a flash point greater than 100° F (38° C).

• Do not spray combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment.

• Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray system, including the pump, hose assembly, spray gun, and objects in and around the spray area shall be properly grounded to protect against static discharge and sparks. Use Graco conductive or grounded high-pressure airless paint sprayer hoses.

• Verify that all containers and collection systems are grounded to prevent static discharge. Do not use pail liners unless they are antistatic or conductive.

• Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2 adapter.

• Do not use a paint or a solvent containing halogenated hydrocarbons.

• Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. Keep pump assembly in a well ventilated area. Do not spray pump assembly.

• Do not smoke in the spray area.

• Do not operate light switches, engines, or similar spark producing products in the spray area.

• Keep area clean and free of paint or solvent containers, rags, and other flammable materials.

• Know the contents of the paints and solvents being sprayed. Read all Material Safety Data Sheets

(MSDS) and container labels provided with the paints and solvents. Follow the paint and solvents manufacturer’s safety instructions.

• Fire extinguisher equipment shall be present and working.

• Sprayer generates sparks. When combustible materials are used in or near the sprayer or for flushing or cleaning, keep sprayer at least 20 feet (6 m) away from explosive vapors.

5

Warnings

6

SKIN INJECTION HAZARD

High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, get immediate surgical treatment.

• Do not aim the gun at, or spray any person or animal.

• Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.

• Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.

• Use Graco nozzle tips.

• Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs while spraying, follow the Pressure Relief Procedure for turning off the unit and relieving the pressure before removing the nozzle tip to clean.

• Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off the unit and follow the Pressure Relief Procedure for turning off the unit.

• Check hoses and parts for signs of damage. Replace any damaged hoses or parts.

• This system is capable of producing 3000 psi. Use Graco replacement parts or accessories that are rated a minimum of 3000 psi.

• Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.

• Verify that all connections are secure before operating the unit.

• Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the influence of drugs or alcohol.

• Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer.

• Do not leave the work area while equipment is energized or under pressure.

• Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.

• Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards.

• Make sure all equipment is rated and approved for the environment in which you are using it.

• Use equipment only for its intended purpose. Call your distributor for information.

• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

• Do not kink or over bend hoses or use hoses to pull equipment.

• Keep children and animals away from work area.

• Comply with all applicable safety regulations.

332641B

332641B

Warnings

ELECTRIC SHOCK HAZARD

This equipment must be grounded .

Improper grounding, setup, or usage of the system can cause electric shock.

• Turn off and disconnect power cord before servicing equipment.

• Connect only to grounded electrical outlets.

• Use only 3-wire extension cords.

• Ensure ground prongs are intact on power and extension cords.

• Do not expose to rain. Store indoors.

PRESSURIZED ALUMINUM PARTS HAZARD

Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.

• Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents.

• Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility.

BURN HAZARD

Equipment surfaces and fluid that is heated can become very hot during operation. To avoid severe burns:

• Do not touch hot fluid or equipment.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

• Keep clear of moving parts.

• Do not operate equipment with protective guards or covers removed.

• Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources.

TOXIC FLUID OR FUMES HAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.

• Read MSDSs to know the specific hazards of the fluids you are using.

• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.

PERSONAL PROTECTIVE EQUIPMENT

Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is not limited to:

• Protective eye wear, and hearing protection.

• Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.

7

8

Component Identification M3+ and M5+

Component Identification M3+ and M5+

H

J

D

G

A

B

C

C1

Airless spray gun

Power switch

Pressure control knob

Setting Indicator

Dispenses fluid.

Turns sprayer ON and OFF.

Increases (clockwise) and decreases (counter-clockwise) fluid pressure in pump, hose, and spray gun.

To select function, align symbol on pressure control knob with setting

indicator, page 13.

Pump fluid outlet fitting

Suction tube

Threaded connection for paint hose.

Draws fluid from paint pail into pump.

Prime tube (with diffuser) Drains fluid in system during priming and pressure relief.

Prime/Spray valve • PRIME position directs fluid to prime tube.

• SPRAY position directs pressurized fluid to paint hose.

• Automatically relieves system pressure in overpressure situations.

L

M

N

Q

R

S

Inlet screen

Paint hose

Handle

Tip guard

Reversible spray tip

Prevents debris from entering pump.

Transports high-pressure fluid from pump to spray gun.

Used to help transport sprayer.

Reduces risk of fluid injection injury.

• Atomizes fluid being sprayed, forms spray pattern and controls fluid flow according to hole size.

• Reverse unclogs plugged tips without disassembly.

Prevents accidental triggering of spray gun.

Gun trigger safety lever

(page 13)

Gun fluid inlet fitting Threaded connection for paint hose.

Power Flush attachment Connects garden hose to suction tube for power flushing water-based fluids.

T

U

V

W

Gun fluid filter

Pail hanger

(M3+ sprayer only)

Power cord X

Z Pump priming button

(M5+ sprayer only)

AA Garden Hose Adapter

Filters fluid entering spray gun to reduce tip clogs.

For transporting pail by its handle.

Supplies sprayer with electricity

Manually taps inlet ball to loosen if stuck.

Connects to Power Flush Attachment and garden hose

332641B

Component Identification M3+ and M5+

M3+ Shown

Z

Component Identification M3+ and M5+

J

X

C

C1

B

N

W

D

G

AA

U

M3+ M5+

H

R

L

Q

S

V

A

M

T ti22057a

332641B 9

Component Identification L10+ and L30+

Component Identification L10+ and L30+

L

M

Q

R

G

H

J

A

B

Airless spray gun

Power switch

Dispenses fluid.

Turns sprayer ON and OFF.

D

E

C

C1

F

F1

Pressure control knob

Setting Indicator

Increases (clockwise) and decreases (counter-clockwise) fluid pressure in pump, hose, and spray gun.

To select function, align symbol on pressure control knob with setting

indicator, page 13.

Threaded connection for paint hose.

Pump fluid outlet fitting

InstaClean™ fluid filter

(L30+ Sprayer Only)

Power-Piston™ Pump, (Not shown. Behind Easy Access door)

(L30+ Sprayer Only)

Pumps and pressurizes fluid and delivers it to paint hose.

Easy Access door

(L30+ Sprayer Only)

• Filters fluid coming out of pump to reduce tip plugging and improve finish.

• Self cleans only during pressure relief.

Easy Access door permits quick access to outlet valve. To remove door, insert flat blade of screwdriver into slot on the bottom of the door

(as shown on page, 11).

K

Suction tube

Prime tube (with diffuser)

Prime/Spray valve

Draws fluid from paint pail into pump.

Drains fluid in system during priming and pressure relief.

• PRIME position directs fluid to prime tube.

• SPRAY position directs pressurized fluid to paint hose.

• Automatically relieves system pressure in overpressure situations.

Automatically taps the inlet ball when you turn the sprayer on.

Autoprime

(L30+ Sprayer Only)

Inlet screen

Paint hose

Tip guard

Reversible spray tip

Prevents debris from entering pump.

Transports high-pressure fluid from pump to spray gun.

Reduces risk of fluid injection injury.

• Atomizes fluid being sprayed, forms spray pattern and controls fluid flow according to hole size.

• Reverse unclogs plugged tips without disassembly.

S

T

U

X

Y

V

W

Gun trigger safety lever (page 13) Prevents accidental triggering of spray gun.

Gun fluid inlet fitting Threaded connection for paint hose.

Power Flush attachment Connects garden hose to suction tube for power flushing water-based fluids.

Gun fluid filter

Hose wrap Rack

Pail hanger

Power Cord

Z Power Flush Adapter

(L30+ Sprayer Only)

AA Pump Priming Button

(L10+ sprayer only)

AB Garden Hose Adapter

Filters fluid entering spray gun to reduce tip clogs.

Stows paint hose.

For transporting pail by its handle.

Supplies sprayer with electricity.

Adapts suction tube (G) to Power Flush attachment (U).

Manually taps inlet ball to loosen if stuck.

Connects to Power Flush Attachment and garden hose

10 332641B

Component Identification L10+ and L30+

Component Identification L10+ and L30+

L30+ Shown

ti9346a

W

B

J

AA ti22077a

K

C ti22095a

Y

G

A

M

Q

R

L

Z

U

AB

S

V

H ti22177a

T ti22176a

332641B

F

C1

E

X

D ti9669a

F1 ti9670a

11

Grounding and Electric Requirements

Grounding and Electric Requirements

Sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for electrical current due to static build up or in the event of a short circuit.

• The 240 VAC sprayers require a 220-240 VAC,

50/60 Hz, 10A circuit with a grounding receptacle.

• Never use an outlet that is not grounded or an adapter.

ti11730a

• Do not use the sprayer if the electrical cord has a damaged ground prong.

• Only use an extension cord with an undamaged

3-prong plug.

Recommended extension cords for use with this sprayer:

• 15 m (49.2 ft) 1.0 mm

2

• 30 m (98.4 ft) 1.5 mm

2

• 50 m (164.0 ft) 2.5 mm

2

Spray gun: ground through connection to a properly grounded fluid hose and pump.

NOTE: Smaller gauge or longer extension cords may reduce sprayer performance.

Fluid supply container : follow local code.

Solvent pails used when flushing : follow local code.

Use only conductive metal pails, placed on a grounded surface such as concrete. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity.

Grounding the metal pail : connect a ground wire to the pail by clamping one end to pail and other end to ground such as a water pipe.

Maintaining grounding continuity : when flushing or relieving pressure hold metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

ti9207a

Thermal Overload

Motor has a thermal overload switch to shut itself down if overheated. If unit overheats, allow approximately 45 minutes for unit to cool. Once cool, switch will close and unit will restart.

To reduce risk of injury from motor starting unexpectedly when it cools, always turn power switch OFF if motor shuts down.

12 332641B

Operation

Operation

Trigger Lock

Always engage the trigger lock when you stop spraying to prevent the gun from being triggered accidentally by hand or if dropped or bumped.

2.

Move Prime/Spray valve to PRIME to relieve pressure. ti9346a ti13961a

M3+ Only

3.

Hold gun firmly to side of pail. Trigger the gun to relieve pressure.

ti8908a

Trigger Locked ti8909a

Trigger Unlocked

Pressure Relief Procedure

Follow this Pressure Relief Procedure whenever you stop spraying and before cleaning, checking, servicing, or transporting equipment.

4.

Engage trigger lock. ti9207a

1.

Turn power switch OFF and unplug power cord.

ti2810a ti8908a

NOTE: Leave Prime/Spray valve in the PRIME position until you are ready to spray again.

If you suspect the spray tip or hose is clogged or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Clear hose or tip obstruction.

Read Unclogging Spray Tip, page 18.

Pressure Control Knob Settings

High Pressure

Spray

Low Pressure

Spray

Prime/

Clean

Rolling

NOTE: To select function, align symbol on pressure control knob with setting indicator on sprayer.

332641B ti5597a

13

Setup

Setup

Prime and Flush Storage Fluid

NOTE: To spray lacquers with the L30+, you must purchase lacquer conversion kit 256212, and follow priming procedure for oil-based materials. The M3+, M5+, and

L10+ units are not intended for lacquers.

1.

Unscrew tip and guard assembly from gun.

Before you use your sprayer for the first time or begin a new spraying project, you need to prime the sprayer and flush the storage fluid out of the sprayer.

Oil- or Water-based Materials

• When spraying water-based materials, flush the system thoroughly with water.

• When spraying oil-based materials, flush the system thoroughly with mineral spirits or compatible, oil-based flushing solvent.

• To spray water-based materials after spraying oil-based materials, flush the system thoroughly with water first. The water flowing out of prime tube should be clear and solvent-free before you begin spraying the water-based material.

• To spray oil-based materials after spraying water-based materials, flush the system thoroughly with mineral spirits or a compatible oil-based flushing solvent first. The solvent flowing out of the prime tube should not contain any water.

• When flushing with solvents, ground pail and gun.

Read Grounding and Electric Requirements, page

12.

• To avoid fluid splashing back on your skin or into your eyes, always aim gun at inside wall of pail.

ti12960a

2.

Uncoil hose and connect one end to gun. Use two wrenches to tighten securely.

ti9681a

3.

Connect other end of hose to sprayer.

ti11456a

NOTE: If hose is already connected, make sure connections are tight.

4.

Turn Pressure Control Knob all the way left

(counter-clockwise) to minimum pressure.

ti9344a

14 332641B

Setup

5.

Make sure the power switch is OFF and the sprayer is unplugged.

11. Push pump priming button two times. ti2810a

6.

Separate prime tube (smaller) from suction tube

(larger).

ti15972a

M5+ and L10+ Only

12. Turn power switch ON.

ti2039a

7.

Place prime tube in waste pail.

WASTE ti5580a

13. Align setting indicator with Prime/Clean setting on

Pressure Control knob until pump starts, page 13.

ti9652a

8.

Submerge suction tube in water or flushing solvent.

ti9718a

14. When sprayer starts pumping, flushing solvent and air bubbles will be purged from system. Allow fluid to flow out of prime tube, into waste pail, for 30 to 60 seconds.

15. Turn power switch OFF.

WATER or

SOLVENT ti9651a

9.

Move Prime/Spray Valve to PRIME.

ti2810a

16. Transfer suction tube to paint pail and submerge suction tube in paint.

ti9346a ti13961a

M3+ Only

10. Plug sprayer in a grounded outlet.

PAINT ti9653a

17. Turn power switch ON.

ti5580a

332641B 15

Setup

18. When you see paint coming out of prime tube: a.

Point gun into waste pail.

b.

Unlock gun trigger lock.

Install Tip and Guard on Gun

1.

Engage trigger lock.

ti8909a c.

Pull and hold gun trigger.

d.

Move Prime/Spray valve to SPRAY.

ti8908a ti9345a ti13960a

M3+ Only

NOTE: Some fluids may prime faster if the Power

Switch is momentarily turned off so the pump can slow and stop. Repeat several times if necessary.

19. Continue to trigger gun into waste pail until you see only paint coming out of gun.

20. Release trigger. Engage trigger lock.

2.

Verify tip and guard parts are assembled in order shown.

retaining nut black rubber gasket and metal seat guard

Use tip to align seat in guard tip ti22117a

Tip must be pushed all the way into guard ti11569a ti11570a ti8908a

21. Transfer prime tube to paint pail and clip prime tube to suction tube.

NOTE: Motor stopping indicates pump and hose are primed with paint. If motor continues to run the sprayer is not properly primed. To reprime, move Prime/Spray

valve to PRIME and repeat step18.

3.

Screw tip and guard assembly on gun. Tighten retaining nut. ti22116a

16 332641B

Setup

Spraying Techniques

Preventing Excessive Tip Wear

• Spray should be atomized (evenly distributed, no gaps at edges). Start at low pressure setting, increase pressure a little at a time until you see a good spray pattern, without tails.

• Spray at lowest pressure that atomizes paint.

• If maximum sprayer pressure is not enough for a good spray pattern, tip is too worn. See Reversible

Spray Tip Selection Chart, page 19.

Getting Started

Use a piece of scrap cardboard to practice these basic spraying techniques before you begin spraying the surface.

• Hold gun 30 cm (12 in.) from surface and aim straight at surface. Tilting gun to direct spray angle causes an uneven finish.

12 in

(30 cm) thick even finish uneven finish thin ti5585a good spray pattern

• Flex wrist to keep gun pointed straight. Fanning gun to direct spray at angle causes uneven finish.

even finish thin thick thin tails- gaps at edges ti5592a ti2036a pressure too low

NOTE: If tails persist when spraying at the highest pressure, a smaller tip is needed or the material may need to be thinned.

Adjust Spray Pressure

This sprayer is set up for most airless spraying applications. Details on tip selection, tip wear, coat thickness,

etc. are provided on page 18.

Triggering Gun

Pull trigger after starting stroke. Release trigger before end of stroke. Gun must be moving when trigger is pulled and released.

ti2037a

NOTE: Motor only runs when gun is triggered. Sprayer is designed to stop pumping when gun trigger is released.

Align setting indicator with function symbol on Pressure

Control knob, page 13.

• Turning knob to the right (clockwise), increases pressure at gun.

• Turning knob to the left (counter-clockwise), decreases pressure at gun.

Aiming Gun

Aim tip of gun at bottom edge of previous stroke, overlapping each stroke by half.

ti2038a

332641B 17

Setup

Unclogging Spray Tip

3.

Aim gun at piece of scrap or cardboard.

4.

Unlock trigger lock. Pull trigger to clear clog.

To avoid fluid splash back

• Never pull gun trigger when arrow-shaped handle is between SPRAY and UNCLOG positions.

• Tip must be pushed all the way into guard.

1.

To UNCLOG tip obstruction, engage trigger lock.

ti8909a

5.

When obstruction is cleared, engage trigger lock and rotate arrow-shaped handle back to SPRAY position.

ti8908a

2.

Point arrow-shaped handle backward to UNCLOG position.

ti12970a

HINT: Point the arrow-shaped handle on the spray tip forward to SPRAY and backward to UNCLOG obstructions.

ti12971a

Tip Selection

Selecting Tip Hole Size

Tips come in a variety of hole sizes for spraying a range of fluids. Your sprayer includes an 0.015 in (0.38 mm) tip for use in most spraying applications. Use the following table to determine the range of recommended tip hole sizes for each fluid type. If you need a tip other than the one supplied, see the Reversible Tip Selection

Chart

on page 19.

HINT:

As you spray, the tip wears and enlarges. Starting with a tip hole size smaller than the maximum will allow you to spray within the rated flow capacity of the sprayer.

Tip Hole Size

0.011 in. (0.28 mm)

0.013 in. (0.33 mm)

0.015 in. (0.38 mm)

0.017 in. (0.43 mm)

0.019 in. (0.48 mm)

Coatings

Stains Enamels Primers Interior Paints Exterior Paints Acrylics

 

18 332641B

Setup

Choosing the Correct Tip

Consider coating and surface to be sprayed. Make sure you use best tip hole size for that coating and best fan width for that surface.

Tip Hole Size

Tip hole size controls flow rate - the amount of paint that comes out of the gun.

HINTS:

• Use larger tip hole sizes with thicker coatings and smaller tip hole sizes with thinner coatings.

• Maximum tip hole sizes supported by sprayer:

• M3+ and M5+: 0.015 in. (0.38 mm)

• L10+: 0.017 in. (0.43 mm)

• L30+: 0.019 in. (0.48 mm)

• Tips wear with use and need periodic replacement.

Fan Width

Fan width is the size of the spray pattern, which determines the area covered with each stroke. Narrower fans deliver a thicker coat, and wider fans deliver a thinner coat.

HINTS:

• Select a fan width best suited to the surface being sprayed.

• Wider fans provide better coverage on broad, open surfaces.

• Narrower fans provide better control on small, confined surfaces.

Understanding Tip Number

The last three digits of tip number (i.e.: 262413) contain information about hole size and fan width on surface when gun is held 30 cm (12 in.) from surface being sprayed.

First digit when doubled

= approximate fan width

413 tip has

8-10 in. fan width

Reversible Tip Selection Chart

Tip Part

No.

Fan Width 30 cm (12 in.) from surface

Hole Size

262311

262411

262313

262413

262415

262515

262417

262517

262619

6 - 8 in.

(152 - 203 mm)

8 - 10 in.

(203 - 254 mm)

6 - 8 in.

(152 - 203 mm)

8 - 10 in.

(203 - 254 mm)

8 - 10 in.

(203 - 254 mm)

10 - 12 in.

(254 - 305 mm)

8 - 10 in.

(203 - 254 mm)

10 - 12 in.

(254 - 305 mm)

12 - 14 in.

(305 - 356 mm)

Example : For an 8 to 10 in. (203 to 254 mm) fan width and 0.013 in. (0.33 mm) hole size, order Part No.

262413.

0.011 in.

(0.28 mm)

0.011 in.

(0.28 mm)

0.013 in.

(0.33 mm)

0.013 in.

(0.33 mm)

0.015 in.

(0.38 mm)

0.015 in.

(0.38 mm)

0.017 in.

(0.43 mm)

0.017 in.

(0.43 mm)

0.019 in.

(0.48 mm)

413 tip has a 0.013 in .

hole size ti22118a

Last two digits = tip hole size in thousands of an inch

332641B 19

Shutdown and Cleaning

Shutdown and Cleaning

Pail Flushing

• For short term shutdown periods (overnight to two

days) refer to Short Term Storage, page 25.

• For flushing after spraying oil-based coatings, use compatible oil-based flushing fluid or mineral spirits.

Read Priming and Flushing Storage Fluid, page 15.

• For flushing after spraying water-based coatings, use water. Read Priming and Flushing Storage

Fluid, page 15 or Power Flush, page 22.

6.

Place prime tube in waste pail.

WASTE ti9652b

7.

Submerge suction tube in water or flushing solvent.

1.

Relieve pressure

, page 13.

2.

Remove tip and guard assembly from gun and place in flushing fluid.

3.

Place empty waste and water or solvent pails side by side.

WATER or

SOLVENT ti9651b

8.

Turn pressure control knob to the Prime/Clean setting.

WATER or

SOLVENT

WASTE ti9726b

4.

Lift suction tube and prime tube from paint pail. Let them drain into paint pail for a while.

5.

Separate prime tube (smaller) from suction tube

(larger).

9.

Turn power switch ON.

ti9344a ti5580a

10. Flush until approximately 1/3 of the flushing fluid is emptied from the pail.

11. Turn power switch OFF. ti2039a ti2018a

20 332641B

Shutdown and Cleaning

NOTE: Step 12 is for returning paint in hose back to paint pail. One 50-ft hose holds approximately 1-quart

(1-liter) of paint.

12. To preserve paint in hose: a.

Point gun into paint pail.

b.

Unlock gun trigger lock.

gun into waste pail until flushing fluid dispensed from gun is relatively clear.

WATER or

SOLVENT

WASTE ti9745a ti8909a c.

Pull and hold gun trigger.

d.

Move Prime/Spray valve to SPRAY.

14. Stop triggering gun. Engage the trigger lock.

ti8908a ti9345a ti13960a

M3+ Only e.

Turn power switch ON.

15. Turn Prime/Spray valve to PRIME.

ti9346a ti13961a

M3+ Only ti5580a

16. Turn power switch OFF.

f.

Continue to hold gun trigger until you see paint diluted with flushing fluid starting to come out of gun.

13. While continuing to trigger gun, quickly move gun to redirect spray into waste pail. Continue triggering ti2018a

17. Clean InstaClean™ Fluid Filter and gun, page 24.

18. Fill unit with Pump Armor™ storage fluid. Read

Long Term Storage, page 25.

332641B 21

Shutdown and Cleaning

Power Flush

Power flushing is a faster method of flushing. It can only be used after spraying water-based coatings.

10. Unscrew inlet screen from suction tube. Place inlet screen in waste pail.

1.

Relieve pressure

, page 13.

2.

Remove tip and guard assembly from gun and place in waste pail.

3.

Place empty waste and paint pails side by side.

ti2040a

11. Connect garden hose to suction tube with Power

Flush attachment. Leave prime tube in waste pail.

ti9414a

PAINT WASTE ti9726b

4.

Lift suction tube and prime tube from paint pail. Let them drain into paint for a while.

5.

Place suction and prime tube in waste pail.

6.

Turn Pressure Control knob to the Prime/Clean setting.

ti2042a

12. Turn power switch ON.

Adapter

L30+ only ti5580a

13. Open valve on Power Flush attachment.

ti9344a

7.

Screw Power Flush attachment to garden hose.

Close valve.

close

OPEN ti9413a

8.

Turn on water. Open valve. Rinse paint off suction tube, prime tube and inlet screen.

open

14. Circulate water through sprayer, into waste pail, for

20 seconds.

15. Turn power switch OFF.

ti9727b

9.

Close valve on Power Flush attachment.

close ti2018a ti9413a

22 332641B

Shutdown and Cleaning

NOTE: Step 16 is for returning paint in hose back to paint pail. One 50-ft (15-m) hose holds approximately

1-quart (1-liter) of paint.

16. To preserve paint in hose: a.

Point gun into paint pail.

b.

Unlock gun trigger lock.

19. Move Prime/Spray valve to PRIME. ti9346a ti13961a

M3+ Only

20. Turn power switch OFF.

d.

ti8909a c.

Pull and hold gun trigger.

Move Prime/Spray valve to SPRAY.

ti2018a

21. Turn off garden hose. Close valve on Power Flush attachment. close ti9345a e.

Turn power switch ON.

ti13960a

M3+ Only ti9413a

22. Unscrew Power Flush attachment from suction tube.

ti5580a f.

Continue to hold gun trigger until you see paint diluted with water starting to come out of gun.

17. While continuing to trigger gun, quickly move gun to redirect spray into waste pail. Continue triggering gun into waste pail until water coming out of gun is relatively clear. ti2047a

23. Clean InstaClean™ Fluid Filter and gun, page 24.

24. Fill unit with Pump Armor™ storage fluid. Read

Long Term Storage, page 25.

WATER

WASTE ti9745a

18. Stop triggering gun. Engage trigger lock.

ti8908a

332641B 23

Shutdown and Cleaning

Cleaning InstaClean™ Fluid

Filter (L30+ Only)

The InstaClean™ Fluid Filter prevents particles from entering paint hose. After each use, remove and clean it to ensure peak performance.

Cleaning Gun

• Clean gun fluid filter (d) with water or flushing solvent and a brush every time you flush the system.

Replace gun filter if damaged.

d ti9668a

1.

Relieve pressure

, page 13.

2.

a.

Disconnect airless spray hose (a) from sprayer b.

Unscrew outlet fitting (b).

c.

Remove InstaClean™ Fluid Filter (c).

• Remove tip and guard and clean with water or flushing solvent. A soft brush can be used to loosen and remove dried on material if needed.

b c a ti9347a

3.

Check InstaClean™ Fluid Filter (c) for debris. If needed, clean filter with water and a soft brush.

a.

Install closed (square) end of InstaClean™

Fluid Filter (c) in sprayer.

b.

Screw outlet fitting (b) into sprayer.

ti9671a

• Wipe paint off outside of gun using a soft cloth moistened with water or flushing solvent. c b ti9347a

4.

Tighten outlet fitting and reconnect hose (a) to sprayer. Use two wrenches to tighten securely.

a ti9674b

24 332641B

Storage

Storage

Short Term Storage

(up to 2 days)

Long Term Storage

(more than 2 days)

1.

2.

Relieve pressure

, page 13.

Leave suction tube and prime tube in paint pail.

Always circulate Pump Armor storage fluid through system after cleaning. Water left in sprayer will corrode and damage pump. Follow Shutdown and Cleaning, page

20, or Power Flush Cleaning, page 22.

1.

Place suction tube in Pump Armor storage fluid bottle and prime tube in waste pail.

ti9353b

3.

Cover paint pail and hoses tightly with plastic wrap.

WASTE ti2057a

2.

Move Prime/Spray valve to PRIME.

4.

a.

Engage trigger lock. ti9350a ti9346a ti13961a

M3+ Only

3.

Turn power switch ON.

ti8908a b.

Leave gun attached to hose. c.

If you have not already cleaned them, remove tip and guard from gun and clean with water or flushing solvent. A soft brush can be used to loosen and remove dried on material if needed.

ti5580a

4.

Turn pressure control knob clockwise until the pump turns on.

ti9671a d.

Wipe paint off outside of gun using a soft cloth moistened with water or flushing solvent.

332641B ti9343b

25

Storage

5.

When storage fluid comes out of prime tube (5-10 seconds) turn power switch OFF.

6.

Move Prime/Spray valve to SPRAY to keep storage fluid in sprayer during storage.

ti2018a ti9345a

M3+ Only ti13960a

Stowing Sprayer

NOTICE

• Before storing sprayer make sure all water is drained out of sprayer and hoses.

• Do not allow water to freeze in sprayer or hose.

• Do not store sprayer under pressure.

1.

Screw inlet screen onto suction tube.

3.

Secure a plastic bag around suction tube to catch any drips.

ti9433a

2.

Coil hose. Leave it connected to sprayer. Wrap hose around hose wrap bracket or sprayer stand.

4.

Store sprayer indoors.

ti5552a ti9366b ti14966a

26 332641B

Maintenance and Service

Maintenance and Service

NOTICE

Protect the internal drive parts of this sprayer from water. Openings in shroud allow cooling of mechanical parts and electronics inside. If water gets into these openings, the sprayer could malfunction or be permanently damaged.

Pump Check Valves

• Storing in water, inadequate flushing or ingested debris can cause either of the two check valves to malfunction.

• If pump does not prime after 30 seconds, try to loosen check balls by pushing pump priming button

(M5+ and L10+ only) or by tapping the inlet valve with a small wrench as the sprayer is stroking.

Caring for Sprayer

Keep sprayer and all accessories clean and in good working order.

To avoid overheating motor, keep vent holes in shroud clear for air flow. Do not cover sprayer while spraying.

ti15972a

M5+ and L10+ Only

NOTICE

Excessive shock will fracture or cause damage to pump. ti14967a ti9355b

Paint Hoses

Check hose for damage every time you spray. Do not attempt to repair hose if hose jacket or fittings are damaged. Do not use hoses shorter than 7.5 m (25 ft).

Wrench tighten, using two wrenches.

NOTE: To verify inlet valve ball is sticking, unscrew valves from pump and check them.

If sprayer continues to cycle (motor and pump run) after you release gun trigger, pump valves may be obstructed or worn. Valve repair kits are available from Graco/Magnum authorized service dealers.

Tips

• Always clean tips with compatible solvent and brush after spraying.

• Tips may require replacement after 57 liters (15 gallons) or they may last through 227 liters (60 ti2055a gallons) depending on abrasiveness of paint.

• Do not spray with worn tip.

Pump Packings

When pump packings wear, paint will begin to leak down outside of pump.

• Replace pump packings at first sign of leaking or additional damage could occur.

• Purchase a pump repair kit and install according to instructions provided with kit.

ti9356a

• Consult a Graco/M AGNUM authorized service center.

332641B 27

Troubleshooting

Troubleshooting

Check everything in this Troubleshooting Table before you bring the sprayer to a Graco/M

AGNUM

authorized service center.

Problem

Power switch is on and sprayer is plugged in, but motor does not run, and pump does not cycle.

Cause Solution

Pressure is set at zero pressure.

Motor or control is damaged.

Turn pressure control knob clockwise to increase pressure setting.

Take sprayer to Graco/M AGNUM authorized service center.

Electric outlet is not providing power. • Try a different outlet or plug in something that you know is working to test outlet.

• Reset building circuit breaker or replace fuse.

Extension cord is damaged.

Sprayer power cord is damaged.

Replace extension cord. Read

Grounding and Electric Require-

ments, page 12.

Check for broken insulation or wires.

Replace power cord if damaged.

Paint and/or water is frozen or hardened in pump.

Unplug sprayer from outlet. If frozen do NOT try to start sprayer until it is completely thawed or you may damage the motor, control board and/or drivetrain.

Make sure power switch is OFF.

Place sprayer in a warm area for several hours. Then plug in power cord and turn sprayer ON. Slowly increase pressure setting to see if motor will start.

If paint is hardened in sprayer, pump packings, valves, drivetrain or pressure switch may need to be replaced.

Take sprayer to Graco/M AGNUM authorized service center.

28 332641B

Problem

Pump does not prime.

Troubleshooting

Cause Solution

Prime/Spray Valve is in SPRAY position.

Move Prime/Spray Valve to PRIME position.

Inlet screen is clogged or suction tube is not immersed in fluid.

Clean debris off inlet screen and make sure suction tube is immersed in fluid.

Pump was not primed with flushing fluid.

Inlet valve check ball is stuck.

Remove suction tube from paint.

Prime pump with water or solvent-based flushing fluid, page 15.

Remove suction tube and place a pencil into the inlet section to dislodge the ball, press pump priming button, or Power Flush sprayer, page

22.

L30+: AutoPrime may need replacement. Turn power switch ON and listen for “tap” in pump. If you do not hear “tap”, AutoPrime is damaged.

Take sprayer to Graco/M AGNUM authorized service center.

Inlet valve check ball or seat is dirty Remove inlet fitting. Clean or replace ball and seat.

Outlet valve check ball is stuck.

L30+: Insert screw driver in slot and remove Easy-Access™ door, page

11. Unscrew outlet valve with a 3/4

in. socket. Remove and clean assembly.

M3+, M5+, and L10+: Remove outlet fitting and clean outlet check ball.

Suction tube is leaking.

Pump does not prime with fluid.

Fluids are viscous or sticky.

Tighten suction tube connection.

Inspect for cracks or vacuum leaks.

Remove suction tube from paint.

Prime pump with water or solvent-based flushing fluid.

Some fluids may prime faster if the

Power Switch is momentarily turned off so the pump can slow and stop.

Repeat several times if necessary.

332641B 29

Troubleshooting

Problem

Pump cycles but does not build up pressure.

Pump cycles, but paint only dribbles or spurts when spray gun is triggered.

Pump is not primed.

Inlet screen is clogged.

Suction tube is not immersed in paint.

Cause

Suction tube is leaking.

Prime/Spray Valve is worn or obstructed with debris.

Pump check ball is stuck.

Pressure is set too low.

Spray tip is clogged.

InstaClean™ fluid filter is clogged.

Spray gun fluid filter is clogged.

Spray tip is too large or worn.

Solution

Prime pump.

Clean debris off inlet screen and make sure suction tube is immersed in fluid.

Make sure suction tube is immersed in paint.

Tighten suction tube connection.

Inspect for cracks or vacuum leaks. If cracked or damaged, replace suction tube.

Take sprayer to Graco/M AGNUM authorized service center.

Read Pump does not prime section

in Troubleshooting, page 29

Slowly turn Pressure Control Knob clockwise to increase pressure setting which will turn motor on to build pressure.

Unclog spray tip, page 18.

Clean or replace InstaClean™ fluid

filter, page 24.

Clean or replace gun fluid filter, page

24.

Replace tip.

30 332641B

Troubleshooting

Problem Cause Solution

Pressure is set at maximum but cannot achieve a good spray pattern.

Reversible spray tip is in UNCLOG position.

Spray tip is too large for sprayer.

Spray tip is worn beyond capability of sprayer.

Select smaller spray tip.

Replace spray tip.

Extension cord is too long or not heavy enough gauge.

Replace extension cord. Grounding and Electrical Requirements, page

12.

Spray gun fluid filter is clogged.

Rotate arrow-shaped handle on spray tip so it points forward in

SPRAY position, page 18.

InstaClean™ fluid filter is clogged.

Inlet screen is clogged.

Pump valves are worn, or debris is clogging valve.

Clean or replace spray gun fluid filter,

page 24.

Clean or replace InstaClean™ fluid

filter, page 24.

Clean debris off inlet screen.

Check for worn pump valves.

a.

Prime sprayer with paint b.

Trigger gun momentarily.

When trigger is released, pump should cycle momentarily and stop. If pump continues to cycle, pump valves may be worn.

c.

Remove valves and check for debris.

Spray gun stopped spraying.

Material is too thick.

Hose is too long (if extra section is added).

Suction tube is leaking.

Thin material.

Remove section of hose.

Tighten suction tube connection.

Inspect for cracks or vacuum leaks.

When paint is sprayed, it runs down the wall or sags.

Spray tip is clogged.

Coat is going on too thick.

When paint is sprayed, coverage is inadequate.

Coat is going on too thin.

Unclog spray tip, page 18.

Move gun faster.

Choose a tip with smaller hole size.

Choose tip with wider fan.

Make sure gun is far enough from surface.

Move gun slower.

Choose tip with larger hole size.

Choose tip with narrower fan.

Make sure gun is close enough to surface.

332641B 31

Troubleshooting

Problem Cause Solution

Fan pattern varies dramatically while spraying.

OR

Pressure control switch is worn and causing excessive pressure variation.

Sprayer does not turn on promptly when resuming spraying.

Cannot trigger spray gun.

Spray gun trigger lock is locked.

Take sprayer to Graco/M AGNUM authorized service center.

Paint is coming out of pressure control switch.

Paint leaks down outside of pump.

Pressure control switch is worn.

Prime/Spray valve actuates automatically relieving pressure through prime tube.

System is over pressurizing.

Pump packings are worn.

Rotate trigger safety lever to unlock

trigger lock, page 13.

Take sprayer to Graco/M

AGNUM authorized service center.

Take sprayer to Graco/M

AGNUM authorized service center.

Replace pump packings.

Motor is hot and runs intermittently.

Motor automatically shuts off due to excessive heat. Damage can occur if cause is not corrected.

Vent holes in enclosure are plugged or sprayer is covered.

Extension cord is too long or not a heavy enough gauge.

See Thermal Overload

, page 12.

Unregulated electrical generator being used has excessive voltage.

Keep vent holes clear of obstructions and overspray and keep sprayer open to air.

Replace extension cord. Read

Grounding and Electrical Require-

ments, page 12.

Use electrical generator with a proper voltage regulator. Sprayer requires 220-240 VAC, 50/60 Hz.

32 332641B

Technical Data

Technical Data

Working pressure range

Electric Motor

Operating horsepower

Maximum delivery (with tip)

Paint hose

Maximum tip hole size

Weight, Sprayer only

Weight, sprayer, hose, & gun

Dimensions (Upright):

Length

Width

Height

Dimensions (Folded):

Length

Width

Height

Power cord

Fluid inlet fitting

Fluid outlet fitting

Inlet screen (on suction tube)

Wetted parts, pump and hose

Wetted parts, gun

Generator requirement

Electrical power requirement

Storage temperature range 

Operating temperature range 

Noise **

Sound Pressure

Sound Power

Magnum M3+ Magnum M5+

0-207 BAR, 0-21 Mpa (0-3000 psi)

4.5A

(open frame, universal)

3/8

.91 lpm (.24 gpm)

1/2

1.02 lpm (.27 gpm)

6.4mm X 7.5 m (1/4 in. x 25 ft)

0.015 in (0.38 mm)

4.5 kg (10.0 lb)

6.0 kg (13.3 lb)

5.4 kg (12 lb)

6.9 kg (15.2 lb)

35.2 cm (13.8 in)

30.7 cm (12.1 in)

35.1 cm (13.8 in)

36.8 cm (14.5 in)

31.5 cm (12.4 in)

45.5 cm (17.9 in)

N/A

N/A

N/A

1.0 mm², 3-wire, 1.8 m (6 ft.)

1/4 npsm external thread

3/4 in. internally threaded

(standard garden hose)

1190 micron (16 mesh) stainless steel, zinc plated carbon steel, brass, ultra-high molecular weight polyethylene (UHMWPE), Carbide, Nylon, Aluminum, PVC, polypropylene, fluroelastomer aluminum, brass, carbide, nylon, ultra-high molecular weight polyethylene

(UHMWPE), zinc

1500 Watt minimum

220-240V AC 50/60 Hz, I phase, 10A

-35° to 71° C (-30° to 160° F)

4° to 46° C (40° to 115° F)

85 dBa

89 dBa

Notes

** Measured while spraying water-based paint, specific gravity 1.36, through a 517 tip at 207 bar, 20.7 Mpa (3000 psi) per ISO 9614-2.

 When pump is stored with non-freezing fluid. Pump damage will occur if water or latex paint freezes in pump.

 Damage to plastic parts may result if impact occurs in low temperature conditions.

 Changes in paint viscosity at very low or very high temperatures can affect sprayer performance.

332641B 33

Technical Data

Working pressure range

Electric Motor

Operating horsepower

Maximum delivery (with tip)

Paint hose

Maximum tip hole size

Weight, sprayer only

Weight, sprayer, hose, & gun

Dimensions (Upright):

Length

Width

Height

Dimensions (Folded):

Length

Width

Height

Power cord

Fluid inlet fitting

Fluid outlet fitting

Magnum L10+ Magnum L30+

0-207 BAR, 0-21 Mpa (0-3000 psi)

4.5A

(open frame, universal)

6.5A

(open frame, permanent magnet DC)

5/8

1.17 lpm (.31 gpm)

7/8

1.44 lpm (.38 gpm)

6.4mm X 15 m (1/4 in. x 50 ft)

0.017 in (0.43 mm) 0.019 in (0.48 mm)

10.6 kg (23.3 lb)

12.7 kg (26.5 lb)

15 kg (33.0 lb)

17.7 kg (37.7 lb)

49.0 cm (19.3 in)

38.9 cm (15.3 in)

94.0 cm (37.0 in)

54 cm (21.3 in)

43.8 cm (17.3 in)

94.5 cm (37.2 in)

49.0 cm (19.3 in)

38.9 cm (15.3 in)

54 cm (21.3 in)

43.8 cm (17.3 in)

74.2 cm (29.2 in) 74.7 cm (29.4 in)

1.0 mm², 3-wire, 1.8 m (6 ft)

3/4 in. internally threaded (standard garden hose)

1/4 npsm external thread

7/8 - 14 UNF external thread

Inlet screen (on suction tube)

Wetted parts, pump and hose

Wetted parts, gun

Generator requirement

Electrical power requirement

Storage temperature range 

Operating temperature range 

Noise **

Sound Pressure

Sound Power

1190 micron (16 mesh) stainless steel, zinc plated carbon steel, brass, ultra-high molecular weight polyethylene (UHMWPE), Carbide, Nylon,

Aluminum, PVC, polypropylene, fluroelastomer

1680 micron (12 mesh) stainless steel, zinc plated carbon steel, brass, leather, ultra-high molecular weight polyethylene (UHMWPE), Carbide, Nylon, Aluminum, PVC, polypropylene, fluroelastomer aluminum, brass, carbide, nylon, ultra-high molecular weight polyethylene

(UHMWPE), zinc aluminum, brass, carbide, nylon, ultra-high molecular weight polyethylene

(UHMWPE), zinc

1500 Watt minimum

220-240V AC 50/60 Hz, I phase, 10A

-35° to 71° C (-30° to 160° F)

4° to 46° C (40° to 115° F)

85 dBa

89 dBa

Notes

** Measured while spraying water-based paint, specific gravity 1.36, through a 517 tip at 207 bar, 20.7 Mpa (3000 psi) per ISO 9614-2.

 When pump is stored with non-freezing fluid. Pump damage will occur if water or latex paint freezes in pump.

 Damage to plastic parts may result if impact occurs in low temperature conditions.

 Changes in paint viscosity at very low or very high temperatures can affect sprayer performance.

34 332641B

Notes

Notes

332641B 35

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by

Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT

LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE .

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy

(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A

PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT

MANUFACTURED BY GRACO . These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English.

Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

TO PLACE AN ORDER or to identify the nearest Graco/M AGNUM distributor, contact us at 1-888-541-9788

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents.

Original instructions.

This manual contains English. MM 332641

Graco Headquarters: Minneapolis

International Offices: Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA

Copyright 2013 Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Revision B, March 2016