165W RIGID SOLAR PANEL

MODEL: FSFP16MW-BL

USER MANUAL

* Product picture for reference only

1

Thank you for purchasing this Furrion® product. Before operating or installing, please read these instructions carefully. This instruction manual contains information for safe use, installation and maintenance of the product.

Please keep this instruction manual in a safe place for future reference. This will ensure safe use and reduce the risk of injury. Be sure to pass on this manual to new owners of this product.

The manufacturer does not accept responsibility for any damages due to not observing these instructions.

CONTENTS

CONTENTS ............................................................................................................................ 2

EXPLANATION OF SYMBOLS........................................................................................ 3

PURPOSE OF THIS GUIDE .............................................................................................. 3

SAFETY PRECAUTIONS .................................................................................................. 4

General Safety Precautions ..................................................................................................................4

Safety Precautions When Installing a Solar Photovoltaic System ..................................4

MECHANICAL INSTALLATION ...................................................................................... 5

General Installation Notes ......................................................................................................................5

Selecting the Mounting Location .......................................................................................................5

Selecting the Proper Mounting Structure and Hardware .....................................................6

Mounting Methods .....................................................................................................................................6

Secure the Solar Panel to the RV Roof ...........................................................................................7

ELECTRICAL CONNECTION .......................................................................................... 7

SHUTTING DOWN THE SYSTEM .................................................................................. 9

MAINTENANCE .................................................................................................................... 9

Maintaining Solar Panel ..........................................................................................................................9

Long Term RV Storage ............................................................................................................................9

SPECIFICATIONS ................................................................................................................ 10

2

3

EXPLANATION OF SYMBOLS

This manual has safety information and instructions to help eliminate or reduce the risk of accidents and injuries. Always respect the safety warnings identified by the following symbols. The following safety phrases indicate the degree of risk of injury or property damage.

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate personal injury, or property damage.

DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

PURPOSE OF THIS GUIDE

Please carefully read the following installation and safety instructions. Noncompliance with these instructions may void the module warranty.

This guide contains information regarding the installation and safe handling of

Furrion photovoltaic modules. All instructions must be read and understood before attempting installation. If there are any questions, please contact your dealer or

Furrion for further information.

The installer should conform to all safety precautions in the guide when installing modules. Before installing a solar photovoltaic system, the installer should become familiar with the mechanical and electrical requirements for photovoltaic systems.

Keep this guide in a safe place for future reference.

Please carefully read the following installation and safety instructions. Noncompliance with these instructions may void the module warranty.

This guide contains information regarding the installation and safe handling of

Furrion photovoltaic modules. All instructions must be read and understood before attempting installation. If there are any questions, please contact your dealer or

Furrion for further information.

The installer should conform to all safety precautions in the guide when installing modules. Before installing a solar photovoltaic system, the installer should become familiar with the mechanical and electrical requirements for photovoltaic systems.

Keep this guide in a safe place for future reference.

SAFETY PRECAUTIONS

General Safety Precautions

– The installation of solar photovoltaic systems requires specialized skills and knowledge. The installer assumes all risk of injury, including risk of electric shock.

Module installation should be performed only by qualified persons.

– All modules come with a permanently attached junction box and PV1-F 1×2.5mm2 wire terminated in PV connectors. Your dealer can provide additional extension cables to simplify module wiring.

– Exercise caution when wiring or handling modules exposed to sunlight.

– Do not connect or disconnect wires attached to photovoltaic modules when modules are exposed to sunlight, otherwise an electric arc may occur. Arcs can cause burns, fires or other safety problems. Always exercise caution when connecting and disconnecting wiring on modules.

– Photovoltaic solar modules convert light energy to direct-current electrical energy and are designed for outdoor use. Proper design of support structures is the responsibility of the system designer and installer.

– Modules may be ground mounted, pole mounted, or mounted on rooftops.

– Do not attempt to disassemble the module, and do not remove any attached nameplates or components. Doing so will void the warranty.

– Do not apply paint or adhesive to the module.

– Do not use mirrors or other hardware to artificially concentrate sunlight on the module.

– When installing modules, observe all applicable local, regional and national codes

& regulations. Obtain a building and/or electrical permit when required.

Work Safely

– Wear protective eye wear and appropriate clothing during installation. Use extreme caution when working with electricity and when working around batteries. Use properly insulated tools only.

– Use care when working on an RV roof, always use rated safety harnesses and ladders during installation and maintenance.

Safety Precautions When Installing a Solar

Photovoltaic System

– Solar modules produce electrical energy when exposed to sunlight.

– Furrion solar modules are intended to be connected in series. However, if modules or series combination of modules are wired in parallel make sure that each

4

module or series combination of modules has the same rated voltage.

– Keep children well away from the system while transporting and installing mechanical and electrical components.

– Completely cover all modules with an opaque material during installation to prevent electricity from being generated.

– Do not wear metallic rings, watches, or other metallic devices while installing or troubleshooting photovoltaic systems.

– Use appropriate safety equipment (insulated tools, insulating gloves, etc.) approved for use on electrical installations.

– Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, mounting hardware, inverters, etc.

– Use only equipment, connectors, wiring and mounting hardware suitable for use in a photovoltaic system.

– Always use the same type of module within a particular photovoltaic system.

– Under normal operating conditions, PV modules will produce currents and voltages that are different than those listed in the data sheet. Data sheet values are applicable at standard test conditions only.

– Short-circuit current and open-circuit voltages should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor ampacity, fuse sizes and size of controls connected to the module or system output.

MECHANICAL INSTALLATION

5

General Installation Notes

– Drainage holes must not be covered with parts of the mounting system. The junction box has a breather port which must be mounted facing downward and cannot be exposed to the rain. The junction box should be on the higher side of the module when it is mounted in order to orient the breather port correctly.

– Do not lift the module by grasping the module's junction box or electrical leads.

– Do not stand or step on the module.

– Do not drop the module or allow objects to fall on the module.

– Do not place any heavy objects on the module.

– Inappropriate transport and installation may damage the module's glass or frame.

Selecting the Mounting Location

– Select a suitable location for the installation of the module.

– The module should be installed to reduce the amount of shading.

– Modules should be mounted as far away from rooftop obstructions (AC units, plumbing vents, skylights, etc.) as possible.

– If solar panels must be installed near rooftop obstructions, try to orient the modules with broadside facing the obstruction. This orientation will optimize the high by-pass diodes in shaded conditions.

– When possible, mount solar panels so that the majority of surfaces can be oriented south facing if roof is positioned accordingly.

Selecting the Proper Mounting Structure and

Hardware

– Observe all instructions and safety precautions included with the mounting system to be used with the module.

– Do not drill holes in the glass surface of the module. Doing so will void the warranty.

– Do not drill additional mounting holes in the module frame. Doing so will void the warranty.

– Modules must be securely attached to the mounting structure using four mounting points for normal installation.

– Load calculations are the responsibility of the system designer or installer. The mounting structure and hardware must be made of durable, corrosion-and UVresistant materials.

– Select mounting location such that screw holes on the mounting brackets attached to the solar panel frame are aligned with the structural framing of the roof.

Mounting Methods

– The module mounting structure must be made of durable, corrosion-resistant and UV- resistant materials. Furrion recommends Z Bracket Mounting Kit, Furrion model number C-FSFP16MW-A02.

– In regions with heavy snowfall in winter, select the height of the mounting system so that the lowest edge of the module is not covered by snow for any length of time. In addition, ensure that the lowest portion of the module is placed high enough so that it is not shaded by plants or trees or damaged by flying sand.

– Modules must be securely attached to the mounting structure.

– Provide adequate ventilation under the modules in conformity to your local regulations. A minimum distance of 13/16" (20mm) between the roof plane and the frame of the module is generally recommended.

– Always observe the instructions and safety precautions included with the module support frames.

– Before installing modules on a roof, ensure that the roof construction is suitable.

6

In addition, any roof penetration required to mount the module must be properly sealed to prevent leaks.

– Observe the linear thermal expansion of the module frames [the recommended minimum distance between two modules is 7/16" (10mm)].

– Always keep the back-sheet of the panel free from foreign objects or structural elements, which could come into contact with the panel, especially when the panel is under mechanical load.

– Ensure panels are not subjected to wind or snow loads exceeding the maximum permissible loads (176lbs/80kg), and are not subject to excessive forces due to the thermal expansion of the support structures.

Secure the Solar Panel to the RV Roof

1. Mount the solar panel through the z-brackets (sold separately) such that at least

2 of the mounting feet have screws penetrating the metal or wooden framing trusses. For fixed mounting, the points should be installed with M6 bolts in the frame on the long side of the panel, as shown below:

7

ELECTRICAL CONNECTION

To power the Solar Photovoltaic System properly, the following Furrion components are also required except the solar panel. Please contact Furrion authorized dealer to purchase the product(s) as required and refer to the individual instruction manual that comes with the product to set up the system.

Furrion Model#

C-FSFP16MW-A02

FSCC30PW-BL/FSCC60PW-BL

C-FSCC60PW-A01/C-FSCC60PW-A02

FSEB30JWL-BL

FBF12A100E

Description

Z-Bracket

MPPT Solar Charge Controller

Temperature Sensor

Rooftop Solar Electrical Box

LiFePo4 Battery Pack

MPPT Solar Charge Controller

FSCC30PW-BL

FSCC60PW-BL

Fuse

+ -

Battery

Temperature Sensor

C-FSCC60PW-A01

C-FSCC60PW-A02

FBF12A100E

+ -

-

Rooftop Solar

Electrical Box

FSEB30JWL-BL

Rigid Solar Panel

FSFP16MW-BL

Fuse\Breaker

Disconnect

Optional

System Connection Diagram

WARNING: Electrical shock hazard! Do not touch bare conductors or other potentially energized parts.

– Any hardware used must be compatible with the mounting structure material to avoid galvanic corrosion.

– It is not recommended to use modules with different configurations (grounding, wiring) in the same system.

– Solar modules must be connected in series when using a Furrion charge controller.

– The current, voltage, and power characteristics of the solar panel(s) will vary based on environmental criteria including temperature and solar irradiance.

– To prevent cables and connectors from overheating, the cross section of the cables and the capacity of the connectors must be selected to suit the maximum system short circuit current (The gauge of system cables is determined by the system designer or installer.).

– The maximum number of solar panels that can be connected in series is dependent on the voltage limit of the MPPT charge controller and the open circuit voltage (Voc) of the solar panel(s) at the coldest anticipated cell temperature. The maximum system voltages of Furrion FSCC30PW-BL MPPT controllers is 70V and Furrion FSCC60PW-BL MPPT controllers 135V. The number of panels used in different configurations are depicted as below.

MPPT Charge Controller

FSCC30PW-BL

FSCC60PW-BL

Max. Number of Solar Panels

2

4

8

9

SHUTTING DOWN THE SYSTEM

1. Completely cover system modules with an opaque material to prevent electricity from being generated while disconnecting connectors.

2. Disconnect system from all power sources in accordance with instructions for all other components used in the system.

The system should now be out of operation and can be dismantled. In doing so, observe all the safety instructions as applicable to installation.

MAINTENANCE

Maintaining Solar Panel

To ensure optimum module performance, Furrion recommends the following maintenance measures:

– Clean the glass surface of the solar panel when required. Always use clean water and a soft sponge or cloth for cleaning. A mild, non-abrasive cleaning agent may be used to remove stubborn dirt. Do not use cold water to clean panel if the surface is extremity hot as rapid temperature change could lead to cracking.

– Clean solar panel more frequently during drier months, as they may become covered in dust more quickly. A pressure washer is not recommended.

– Check the electrical, grounding and mechanical connections every six months to verify that they are clean, secure, undamaged and free of corrosion.

– Remove snow, ice, or other debris when build up occurs.

– Caution: Observe the maintenance instructions for all components used in the system, such as support frames, PV connectors, charge controller, inverter, batteries, etc.

Long Term RV Storage

If your RV will be stored in extremely cold climates you may need to remove your batteries to prevent them from freezing. Please note if your solar panel(s) are covered by snow they will not produce power and can not be depended upon to keep the batteries charged. For battery storage in mild climates solar system will provide more power provided sufficient sunlight and limited load. Make sure that all passive/ phantom loads are removed from the batteries, i.e. DVD players, clock radio, etc. to make sure the solar panel(s) can keep the batteries charged even with reduced sun exposure.

SPECIFICATIONS

Furrion solar modules are made of monocrystalline solar cells in series with high efficiency, high transmission rate, low iron tempered glass, anti-aging EVA, high flame resistant TPT laminate, and anodized aluminum alloy frames. They are designed for easy installation, extended longevity, and resistance to damage incurred by high wind or hail.

Specifications

Output cable

Connectors

Junction box

Bypass diode

Construction

Frame

Insulation

Dimension (W x H x D)

Weight

Solar cell

Max Power (Pmax)

Operating Voltage (Vmp)

Operating Current (Imp)

Open-Circuit Voltage (Voc)

PV1-F 1×2.5mm²

Furrion Connectors

IP65 Rated

Schottky Barrier Rectifiers Diode

Front: high transmission rate and low iron tempered glass 1/8" (3.2mm)

Back: TPT

Encapsulation material: EVA

Black Anodized Aluminum

50MΩ

523/8 x 265/8 x 13/8” (1330 x 675 x 35mm)

21.39lbs (9.7kg)

36 pieces monocrystalline silicon solar cell

165W

19.4V

8.5A

28.83V

Short-Circuit Current (Isc) 8.91A

Output Tolerance

Max Series Fuse Rating

±3%

20A

Cell Efficiency 22.7%

Temperature Coefficient of Voc -0.32%/°C

Temperature Coefficient of Isc +0.05%/°C

Temperature Coefficient of

Pmax

-0.41%/°C

Operating Temperature -40°F to +185°F (-40°C to +85°C)

NOTE: All technical data at standard test condition (E=1000W/m² TC=25°C AM=1.5)

10

Furrion Innovation Center & Institute of Technology

● 52567 Independence Ct., Elkhart, IN 46514, USA ● Toll free:1-800-789-3341

● Email: [email protected]

©2007-2021 Furrion Ltd. Furrion® and the Furrion logo are trademarks licensed for use by Furrion Ltd. and registered in the U.S. and other countries.

For Patent Info: www.furrion.com/pages/patents

FURRION.COM

IM-FEN00013 V2.0

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals