American Standard HVAC AUD1C120A9541A 21 in. 120000 BTU 80% AFUE 5 Ton Single-Stage Upflow and Horizontal Left 1/2 hp Natural or Propane Furnace Specification
American Standard HVAC AUD1C120A9541A is a high-efficiency gas furnace that provides reliable heating for your home. It features a durable, cycle-tested, heavy-gauge aluminized steel heat exchanger for efficient heat transfer and a low-energy power vent blower for increased efficiency and safe gas fume discharge. The integrated system control ensures safe operation with continuous flame monitoring, self-diagnostics, and limit sensors. The multi-speed, direct-drive blower motor adjusts airflow for heating and cooling needs and includes a blower door safety switch for added protection.
Advertisement
Advertisement
AUD1C120-SPEC-1
TAG: _________________________________
5/8"
Specification
Upflow / Horizontal Gas
Furnace"Fan-Assisted
Combustion"
AUD1C120A9541A
21"
19-3/4"
5/8"
19-5/8"
28-3/8"
1/2"
5/8"
7/8" DIA. HOLES
ELECTRICAL
CONNECTION
13-1/16"
4" DIAMETER
FLUE CONNECT
4-1/16" 1/2"
3/4"
19-1/2"
3/4"
8-1/4"
3-15/16"
2-1/16"
2-1/16" 7/8" DIA. K.O.
ELECTRICAL
CONNECTION
(ALTERNATE)
3-3/4"
40"
1-1/2" DIA.
K.O. GAS
CONNECTION
(ALTERNATE)
28-1/4"
3/4"
28-1/4"
22-1/2"
23-1/2"
3-13/16"
5-5/16"
3/8"
2-1/8"
1-1/2" DIA. HOLE
GAS CONNECTION
FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.)
MODEL SPEED TAP
AUD1C120A9541A 4 -
3 -
2 -
1 -
HIGH - Black
MED.-HIGH - Blue
MED.-LOW - Yellow
LOW - Red
0.10
2162
1889
1654
1427
0.20
2130
1881
1643
1421
0.30
2097
1873
1631
1414
0.40
2067
1839
1619
1400
0.50
2037
1805
1606
1386
0.60
1976
1776
1572
1357
0.70
1914
1746
1538
1327
0.80
1833
1670
1483
1285
0.90
1752
1593
1428
1243
MODEL
AUD1C120A9541A
1400
63
1500
59
1600
CFM VS. TEMPERATURE RISE
CFM (CUBIC FEET PER MINUTE)
1700 1800 1900 2000
56 52 49 47 44
2100
42
2200
40
© 2008 American Standard Heating & Air Conditioning
General Data
1
TYPE
RATINGS 2
Input BTUH
Capacity BTUH (ICS) 3
AFUE
Temp. rise (Min.-Max.) °F.
BLOWER DRIVE
Diameter-Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts/Ph/Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts/Ph/Hz
F.L. Amps
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
Upflow / Horizontal
120,000
96,000
80.0
35 - 65
DIRECT
11 x 10
1
4
See Fan Performance
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/50 - 3180
115/1/60
1.09
No
High Velocity
1 - 20x25 - 1in.
VENT COLLAR — Size (in.)
HEAT EXCHANGER
Type-Fired
-Unfired
Gauge (Fired)
ORIFICES — Main
Nat.Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V/Ph/Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
Uncrated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
4 Round
Alum. Steel
20
6 — 45
6 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
6
115/1/60
13.4
20
1/2
H x W x D
41- 3/4 x 23 x 30-1/2
40 x 21 x 28
176 / 164
1
2
3
4
Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories.
Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
Based on U.S. Government Standard Tests.
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
Mechanical Specifications
NATURAL GAS MODELS — Central heating furnace designs are certified by the
American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
SAFE OPERATION — The Integrated
System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety.
QUICK HEATING — Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower , to increase efficiency and provide discharge of gas fumes to the outside, allows common venting with hot water heater.
BURNERS — Multi-port, in-shot burners will give years of quiet and efficient service.
All models can be converted to L.P. gas without changing burners.
INTEGRATED SYSTEM CONTROL — Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service.
AIR DELIVERY — The multispeed, directdrive blower motor, with sufficient airflow range for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. (Fan relay and 35VA control transformer is standard).
STYLING — Heavy gauge steel and
"wraparound" cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil-faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass.
FEATURES AND GENERAL OPERA-
TION — These High Efficiency Gas Furnaces employ a Hot Surface Ignition system, which eliminates the waste of a constantly burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access.
a. Low energy power venter.
b. Vent proving differential switch.
American Standard
Heating & Air Conditioning
6200 Troup Highway
Tyler, TX 75707
Since American Standard Heating & Air Conditioning has a policy of continuous product and product data improvement, it reserves the right to change specifications and design without notice.
Library
Product Section
Product
Model
Literature Type
Sequence
Date
File No.
Supersedes
-
-
Furnace
AUD1
Submittal
-
02/08
AUD1C120-SPEC-1
AUD1C120A9541A
Download