GE AZ65H12DAB Zoneline® Heat Pump Unit, 230/208 Volt Guide
Add to my manuals
24 Pages
GE AZ65H12DAB is a packaged terminal air conditioner that provides both cooling and heat pump functionality, making it an ideal choice for year-round comfort in hotel rooms, apartments, and other commercial spaces. With its high energy efficiency rating and advanced features, the GE AZ65H12DAB is designed to deliver superior performance and guest satisfaction.
advertisement
ZONELINE®
Packaged Terminal Air Conditioners
Product & Accessories Guide
ZONELINE ®
RELIABILITY
With over one million units installed across the U.S.
and remarkably low service issues, GE Zoneline PTACs offer unrivaled reliability, consistent performance and constant guest comfort.
UNMATCHED
SERVICE & SUPPORT
GE Appliances is the only manufacturer with a dedicated factory service network and field team. Our technicians service your Zoneline—and any other GE appliances you have—in no time, so guest comfort is not compromised.
QUIETER & BETTER
SOUND QUALITY
The Quietest PTAC in the industry* GE Zoneline is so quiet your guests won’t even know it’s there.
BEST OITC
against leading competitors.
(Outdoor Indoor Transmission Class)
Standard on all units. Higher is better .
29
20
OITC RATING
BEST STC
against leading competitors.
(Sound Transmission Class)
Standard on all units. Higher is better .
QUIETER THAN
LEADING COMPETITORS
Sound Transmission Class & Outdoor Indoor Transmission
Class measured by Independent third party testing at nationally accredited certified acoustic lab, conducted March 2015 and
October 2015 in accordance with ASTM and AHRI standards.
2
New
ZONELINE®
COMPETITOR
A
COMPETITOR
A2
COMPETITOR
B
COMPETITOR
C
* Randomized test of 7,000, 9,000, 12,000 and 15,000 BTUh models against equivalent leading competitor unit, September 2015 installed in hotel property.
* When compared to leading competitors. 12,000 BTUh heat pump models tested by independent third-party testing at a national acoustical lab, conducted
March 2015 and October 2015, in accordance with ASTM and AHRI standards. The higher the STC rating, the better the unit blocks outside noise.
Independent third party testing at nationally accredited certified acoustical lab, conducted March 2015 and October 2015 in accordance with ASTM and AHRI standards.
P h D
Designed, engineered and assembled in the U.S., GE Zoneline
Packaged Terminal Air Conditioning units are built to last.
ROOM NOISE & TEMP
MAKE A BIG DIFFERENCE
66% of dissatisfied guests are unlikely to return due to poor noise and temperature control.**
33% of dissatisfied guests are unlikely to recommend the hotel for those reasons.**
MORE POWER
LESS NOISE
GE® Zoneline® has the largest fan vs. leading competitor designs, which means less rotation and quieter performance.
EXPERT BRAINPOWER
AT WORK
The GE® Appliances team includes sound acoustics and mechanical engineers, with both a Master’s Degree in sound transmission and a Ph.D. in Acoustics. These experts helped develop the design within our own state-of-the-art PTAC sound lab.
MANAGE YOUR ZONELINE
FROM ANYWHERE
Take control of your properties with the industry’s most powerful management software.
** Clarabridge Ratings and Reviews, for hospitality data collected July 2013-June 2014.
3
ZONELINE® QUIET FEATURES
AVAILABLE ON ALL MODELS
BAKED-ON MASTIC
SOUND BARRIER
A heavy-duty barrier covers the back of the unit for superior sound insulation.
BLOWER & DC MOTORS
A large cross-flow blower and two DC fan motors keep the unit quiet for customers & guests while providing smart fan cooling & heating performance.
WEATHER BARRIER
SYSTEM SEAL
A seal around the perimeter of the units keeps noise and dirt outside.
ZONELINE® STANDARD FEATURES
AVAILABLE ON ALL MODELS
SYSTEM COMPATIBILITY
Compatible with a wide variety of thermostats and energy management systems, including central desk control.
EFFICIENT HEAT PUMP
Exclusive Reverse Cycle Defrost increases efficiency and allows unit to run in heat pump mode longer. Backup resistance heat provides comfort during severe cold temperatures. Available on all heat pump models.
ELECTRONIC TOUCH
CONTROLS
Easy-to-use controls with clear
LED readout provide a user-friendly experience.
4
HEAT & FREEZE SENTINEL
Keeps room from overheating or freezing while meeting guest comfort and protecting against damage.
BASE PAN
Made of sheet-molding compound (SMC) & durable resin, the base pan resists rust.
VISIT ZONELINE.COM OR CALL 888.231.2548
ELECTRONIC
TEMPERATURE LIMITING
Prevents expensive overcooling and overheating of rooms. Limits are factory set for savings, but can be adjusted to meet specific needs.
ZONELINE® SPECIALTY MODELS
CORROSION PROTECTION *
Double-coated painted surfaces and stainless steel components ensure lasting performance in challenging environments such as oceanfront properties.
MAKEUP AIR *
A secondary system provides continuous outdoor air. The supplemental dehumidification system operates when outdoor temperatures are above 50 degrees F and when relative humidity levels rise above
55%. Available on select models.
DRY AIR 25 *
Zoneline Dry Air models remove
20%-35% more moisture from the air than standard Zoneline air conditioners,** making them perfect for high humidity climates.
INTERNAL CONDENSATE
REMOVAL (ICR) *
A system that minimizes the amount of condensate draining from the unit when in heat pump mode.
*Available on select models.
** Varies when comparing dehumidification rates of the 7,000/9,000/12,000 BTU base models to Dry Air model counterparts. AZ45 Series electric resistance models only.
VISIT ZONELINE.COM OR CALL 888.231.2548
5
6
ZONELINE® PACKAGED TERMINAL AIR CONDITIONERS
AZ45 SERIES | COOLING AND ELECTRIC HEAT
• Digital LED display
• Variable fresh air vent control
• Cross-flow blower
• Two DC fan motors
• Smart fan cooling
• Heat and Freeze Sentinel
• Remote thermostat capability
• Electronic temperature limiting
• Works with central desk control and through wall fans
AZ45 SERIES 230V/208V
BASE
BTU
AZ45E07DAB
AZ45E09DAB
AZ45E12DAB
AZ45E15DAB
7,200/7,000
9,700/9,600
11,600/11,500
14,200/14,100
EER
13.4/13.4
12.1/12.1
11.7/11.8
10.5/10.5
CORROSION PROTECTION
BTU
AZ45E07DAC
AZ45E09DAC
AZ45E12DAC
AZ45E15DAC
7,200/7,000
9,400/9,300
11,600/11,500
14,000/13,900
EER
13.4/13.4
11.8/11.8
11.7/11.8
10.3/10.4
Volts
230/208
230/208
230/208
230/208
Volts
230/208
230/208
230/208
230/208
AZ45 SERIES 265V
CORROSION PROTECTION
BTU
AZ45E07EAC 7,100
AZ45E09EAC
AZ45E12EAC
AZ45E15EAC
9,500
11,500
14,700
EER
13.2
11.6
11.7
10.5
Volts
265
265
265
265
DRY AIR 25
AZ45E07DAP
AZ45E09DAP
AZ45E12DAP
BTU
6,900/6,800
9,400/9,300
11,200/11,100
EER
12.8/12.8
12.1/12.1
11.4/11.5
Volts
230/208
230/208
230/208
DRY AIR 25
AZ45E09EAP
AZ45E12EAP
BTU
9,400
10,900
EER
12.1
11.0
Volts
265
265
AZ45 GE ZONELINE® WITH MAKEUP AIR
Includes all AZ45 features plus:
• Delivers 25-50 CFM of continuous, Makeup Air
• Dehumidifies incoming air when outdoor relative humidity is above 55% and outdoor temperatures are above 50 degrees F
• Motorized vent door
• May reduce the need for rooftop units
AZ65 SERIES | HEAT
PUMP WITH
MAKEUP AIR
Includes all resistant heat
Makeup Air features, plus:
• Staged heating
• Heat pump with back up resistance heat option
• Reverse cycle defrost
MAKEUP AIR
AZ45E09DBM
AZ45E12DBM
MAKEUP AIR
AZ65H07DBM
AZ65H09DBM
AZ65H12DBM
AZ65H15DBM
Cooling BTU
7,000/7,000
9,200/9,100
11,500/11,400
14,000/13,800
Heating BTU
6,200/6,100
8,000/7,900
10,200/10,000
13,200/13,000
MAKEUP AIR
BTU
9,100/9,100
11,700/11,500
EER
12.5/12.5
11.3/11.3
11.2/11.2
10.1/10.1
AZ65H07EBM
AZ65H09EBM
AZ65H12EBM
Cooling BTU
6900
9,200
11,600
Heating BTU
6000
8,100
10,000
EER
12.5
11.5
11.3
EER
11.5/11.5
11.6/11.6
COP*
4.0/4.0
3.3/3.3
3.5/3.5
3.2/3.2
COP*
3.9
3.6
3.4
Volts
230/208
230/208
Volts
230/208
230/208
230/208
230/208
Volts
265
265
265
NOTE: Because Makeup Air increases room BTU load requirements and requires additional PTAC cooling or heating, the building’s electrical needs may be impacted.
NOTE: Makeup Air models listed above are not recommended for installation within two miles of coastal areas.
NOTE: It is strongly recommended to install Makeup Air with wall thermostats.
Specifications subject to change.
ZONELINE® PACKAGED TERMINAL AIR CONDITIONERS
AZ65 SERIES | HEAT PUMP
Includes all resistant heat features, plus:
• Staged heating
• Heat pump with back up resistance heat option
• Reverse cycle defrost
AZ65 SERIES 230V/208V
BASE
AZ65H07DAB
AZ65H09DAB
AZ65H12DAB
AZ65H15DAB
Cooling BTU Heating BTU
7,100/6,900 6,200/6,100
9,700/9,600 8,100/8,000
11,900/11,800 10,400/10,300
14,400/14,200 13,500/13,300
EER
13.0/13.0
12.2/12.2
11.6/11.8
10.5/10.5
CORROSION PROTECTION
Cooling BTU
AZ65H07DAC
AZ65H09DAC
AZ65H12DAC
AZ65H15DAC
Heating BTU
7,100/7,000 6,200/6,100
9,600/9,500 8,100/8,000
11,800/11,600 10,300/10,200
14,400/14,200 13,200/13,000
EER
13.0/13.0
12.2/12.2
11.8/11.8
10.4/10.4
INTERNAL CONDENSATE REMOVAL
Cooling BTU Heating BTU
AZ65H07DAD 7,000/6,900 6,200/6,000
AZ65H09DAD 9,600/9,500 8,200/8,000
AZ65H12DAD 11,800/11,600 10,400/10,200
AZ65H15DAD 14,100/14,100 13,200/13,000
EER
13.0/13.0
12.0/12.0
11.5/11.5
10.3/10.3
COP*
4.0/4.0
3.7/3.7
3.6/3.6
3.2/3.2
Volts
230/208
230/208
230/208
230/208
COP*
4.0/4.0
3.7/3.7
3.6/3.6
3.2/3.2
Volts
230/208
230/208
230/208
230/208
COP*
4.0/4.0
3.6/3.6
3.5/3.5
3.2/3.2
Volts
230/208
230/208
230/208
230/208
AZ65 SERIES 265V
CORROSION PROTECTION
Cooling BTU
AZ65H07EAC 7,000
AZ65H09EAC
AZ65H12EAC
AZ65H15EAC
9,500
11,500
14,000
Heating BTU
6,200
8,100
10,000
13,200
INTERNAL CONDENSATE REMOVAL
Cooling BTU Heating BTU
AZ65H07EAD 7,000 6,200
AZ65H09EAD
AZ65H12EAD
AZ65H15EAD
9,500
11,600
14,200
8,100
10,000
13,300
EER
12.8
11.7
11.2
10.0
EER
12.8
11.7
11.4
10.3
COP*
3.9
3.5
3.4
3.2
COP*
3.9
3.6
3.5
3.1
Volts
265
265
265
265
Volts
265
265
265
265
Specifications subject to change.
*Coefficient of Performance
VISIT ZONELINE.COM OR CALL 888.231.2548
7
8
ELECTRICAL CONNECTION/SUB-BASE
GE ZONELINE SPECIFICATION — RESISTANCE HEATER WATTAGE
The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if the unit is to be permanently connected, a direct connect or permanent connection kit would be used. Cord set units of 265 volts must be installed in compliance with
National Electrical Code. (Article 440.60)
POWER CONNECTION KITS
Required on all models. See specification information below for heater kWh and branch circuit ampacity.
GE Zoneline offers short and long power cords, direct connect universal supply kits and sub bases.
Power connection kits are required for all models. See pages 11 and 12 for all product options.
Receptacles/Sub-bases
Tandem
230/208V 15 Amp
NEMA6-15R
Perpendicular
230/208V 20 Amp
NEMA6-20R
Large tandem
230/208V 30 Amp
NEMA6-30R
265V 15 amp
NEMA7-15R; receptacle used on
265V sub-base
265V 20 amp
NEMA7-20R; receptacle used on
265V sub-base
265V 30 amp
NEMA7-30R; receptacle used on
265V sub-base
GE ZONELINE SPECIFICATIONS —RESISTANCE HEATER WATTAGE
BTUh size
Power connection kit
Total watts
Heater watts
Heater BTUh
Total amps
MCA
Recommended protective device
(MOCP)
230/208-Volt Line-Cord Connected (P) and Direct Connected Units (D)
7,000/9,000 12,000/15,000
RAK315P &
RAK315D**
2,410/1,990
2,400/1,960
8,100/6,600
10.5/9.6
15
RAK320P &
RAK320D**
3,420/2,830
3,400/2,780
RAK330P &
RAK330D**
4,830/3,990*
4,800/3,930*
11,600/9,400 16,300/13,400*
14.9/13.6
21.0/19.2
20 25
RAK315P &
RAK315D**
2,430/2,020
2,400/1,960
8,100/6,600
10.6/9.7
15
RAK320P &
RAK320D**
3,450/2,860
3,400/2,780
RAK330P &
RAK330D**
4,860/4,020*
4,800/3,930*
11,600/9,400 16,300/13,400*
15.1/13.8
21.2/19.3
20 25
15 amp time-delay fuse or breaker
20 amp time-delay fuse or breaker
30 amp time-delay fuse or breaker
15 amp time-delay fuse or breaker
20 amp time-delay fuse or breaker
30 amp time-delay fuse or breaker
BTUh size
Power connection kit
Total watts
Heater watts
Heater BTUh
Total amps
MCA
265-Volt
RAK515P &
RAK515D
2,440
2,400
8,100
9.1
15
Permanent (P, Cord Set) and Direct-Connected Units (D)
7,000/9,000
RAK520P & RAK530P & RAK515P &
12,000/15,000
RAK520P &
RAK520D
3,450
3,400
11,600
12.9
20
RAK530D
4,850*
4,800*
16,300*
18.1
25
RAK515D
2,460
2,400
8,100
9.3
15
RAK520D
3,470
3,400
11,600
13.1
20
RAK530P &
RAK530D
4,870*
4,800*
16,300*
18.4
25
Recommended protective device
(MOCP)
15 amp time-delay fuse or breaker
20 amp time-delay fuse or breaker
25 amp time-delay fuse or breaker
15 amp time-delay fuse or breaker
20 amp time-delay fuse or breaker
25 amp time-delay fuse or breaker
Each line cord kit has an integral Leakage Current Detection and Interruption (LCDI) device as required by
National Electrical Code (NEC) and Underwriters Laboratories (UL) for units manufactured after August 1, 2004.
Specifications subject to change.
Total watts and total amps include electric heat and fan motor(s).
RAK515P, RAK520P and RAK530P are only to be used with a sub-base.
*30 AMP heater wattage will be reduced in low fan operation.
**Direct connect kits require the purchase of the RAK4002D junction box.
VISIT ZONELINE.COM OR CALL 888.231.2548
ZONELINE® WALL SLEEVE ACCESSORIES
(COLOR MATCHED FOR AZ45-65 SERIES)
DELIVERING RELIABLE COMFORT.
Only genuine parts and accessories from GE Appliances keep your Zoneline ® units running in peak condition.
Engineered and constructed from high-quality materials for a guaranteed fit, convenient replacement and constant comfort.
RAB78B
4 PIECE QUICK SNAP DESIGN SMC SLEEVE
42" EXTENDED DEPTH
• Stainless steel locking components
• Fiberglass reinforced polyester compound
• Color matched and standard size
• Insulated top and sides
RAB81
QUICK SNAP WALL SLEEVE
• Universal design
• Insulated top & sides
• Heavy gauge metal
• Color matched
• 4-piece “quick snap” design
• Ships flat (3" H x 15" D x 45.5" L) assembled in field
RAB81B
WALL SLEEVE
• Universal design
• Insulated top & sides
• Heavy gauge metal
• Color matched
• 4-piece “quick snap” design
• Ships fully assembled
RAB8116B
QUICK SNAP WALL SLEEVE 16" EXTENDED DEPTH
Other extended depths available:
RAB8118B: Quick Snap Wall Sleeve 18" extended depth
RAB8120B: Quick Snap Wall Sleeve 20" extended depth
RAB8124B: Quick Snap Wall Sleeve 24" extended depth
VISIT ZONELINE.COM OR CALL 888.231.2548
9
ZONELINE® OUTDOOR GRILLE ACCESSORIES
(FOR AZ SERIES)
RAK40
AIR DEFLECTOR KIT
• Adapts AZ chassis for use with other non-GE
architectural grilles
• Aluminum deflector installed to condenser end sheet flanges to prevent condenser airflow recirculation
RAG60
STAMPED ALUMINUM EXTERIOR REAR GRILLE
• Optimizes air flow
• Made of durable aluminum
RAG61/62/63
ARCHITECTURAL REAR GRILLE
• Improves appearance and protection
• Molded of high-impact polycarbonate
• Slightly textured, colorfast surface blends with most walls
RAG61: Beige | RAG62: Maple | RAG63: Dark Brown
RAG67
ALUMINUM ARCHITECTURAL OUTDOOR GRILLE
• Extruded aluminum outdoor grille
• Grilles are paintable to match building décor
10
WP71X20960
REPLACEMENT ROOM CABINET
• Wraparound design with textured finish
• Injection-molded with high-impact polystyrene
• Fastens to chassis without tools or hardware
• Includes slide-out filters for AZ45/65 series
• Available through geapplianceparts.com
RAD10
(ALL ZONELINE SERIES)
INTERNAL/EXTERNAL DRAIN KIT
• Provides positive control of condensate water
• Routes condensate to exterior or interior of the building
• Suitable provision (field applied) required for connection to drain system
• 1/2" OD copper assemblies
• Includes short right-angle tube and 3"-long straight tube
VISIT ZONELINE.COM OR CALL 888.231.2548
ZONELINE® ACCESSORIES
(COLOR MATCHED FOR AZ45-65 SERIES)
RAK6053 (New Installations)
DUCT ADAPTER
• For use with new ducted installations
• Allows Zoneline unit to heat or cool an adjacent room
• Attaches to top of wall case
• Can direct air to the left or right side of adapter with
RAK601B extension
7-3/32"
6-1/2"
RAK44 (5 Pack)
PTAC CURTAIN GUARD
• Durable polycarbonate
• UV Resistant
• 125 degrees air deflection angle
• Easy to install with no tools needed
• Attaches with pressure sensitive adhesive
8-3/8"
RAK7023
DUCT TRANSITION FOR REPLACEMENT
OF EXISTING ZONELINES
7-3/32" H x 6-1/2" W DUCTWORK
• Allows existing duct adapter and extension to be used without requiring relocation of wall hole
6-1/2"
RAK7013
DUCT ADAPTER FOR NEW UNITS WITH OLD DUCTWORK
THAT MEASURES 8-3/8" H x 6-1/2" W
• For use with existing ducted installations where ductwork
dimensions match those shown about (prior to 1998)
• Allows existing duct extension to be used without requiring relocation of wall hole
• Must use discharge grille, end plate and extension mounting hardware from old duct adapter
RAK601B (Includes one RAK602B)
DUCT EXTENSION, REGISTER & TRIM FLANGE
• 44" long
• Includes air register and trim flange (RAK602B)
for secondary space
• Additional air register and trim flange can be ordered separately if two extensions are made
• For use with RAK6053
VISIT ZONELINE.COM OR CALL 888.231.2548
11
ZONELINE® ACCESSORIES
(FOR AZ45-65 SERIES)
Chaseway
12
RAK204D*
230/208 SUB-BASES WITH POWER CORD INCLUDED
• Made of heavy-gauge steel
• Full base enclosure with adjustable side channels
• 4-point leveling legs
• Sub-base adapts to service conduit, circuit breakers and receptacles up to 30 amps
Kit No.
RAK204D15C
RAK204D20C
RAK204D30C
Sub-Base
Sub-Base
230V/208V
Sub-Base
230V/208V
Sub-Base
230V/208V
Circuit
Ampacity
15
20
30
Chaseway
Included
Included
Included
Power
Cord
Included
Included
Included
*Requires the purchase of the RAK4002D Junction box
Chaseway
Power cord and junction box not included with sub-base.
RAK204U
SUB-BASES
• Made of heavy-gauge steel
• Full base enclosure with breakaway side channels
• 4-point leveling legs
• Used as a non-electrical sub-base to support the unit
Kit No.
RAK204U
Sub-Base
Circuit
Ampacity
Standard N/A
Chaseway
Included
Power
Cord
RAK204E
265V SUB-BASES WITH POWER CORD INCLUDED
• Made of heavy-gauge steel
• Full base enclosure with adjustable side channels
• 4-point leveling legs
• Sub-base adapts to service conduit, circuit breakers and receptacles up to 30 amps
Kit No.
RAK204E15C
RAK204E20C
RAK204E30C
Sub-Base
Sub-Base
265 V
Sub-Base
265 V
Sub-Base
265 V
Circuit
Ampacity
15
20
30
Chaseway
Included
Included
Included
Power
Cord
Included
Included
Included
RAK205CW
CHASEWAY
• For wiring containment between junction box on chassis and RAK204U sub-base
Available while quantities last
RAK204SW
DISCONNECT SWITCH FOR USE IN SUB-BASE
• Fits directly into sub-base
• Comes with switch pre-mounted in replacement plate
and wiring shown.
• DPST switch rated for use in 230/208 volt and 265-volt
sub-bases
• For use on 15, 20, and 30-amp applications
VISIT ZONELINE.COM OR CALL 888.231.2548
ZONELINE® ACCESSORIES POWER CORDS/CONNECTIONS
(FOR AZ45-65 SERIES)
RAK315P/320P/330P†
RAK320P shown
230/208-VOLT UNIVERSAL POWER
CORD KIT
• Six-foot power cord with LCDI
• 4-pin connector
• Low-voltage personality plug on 20 amp and 30 amp kits
Kit No.
RAK315P
RAK320P
RAK330P
Volts
Heater
Wattage
Circuit
Ampacity
230/208 2.4/1.96 kw 15
230/208 3.4/2.8 kw 20
230/208 4.8/3.99 kw 30
RAK315SP/320SP/330SP†
RAK315SP shown
230/208-VOLT UNIVERSAL SHORT
POWER CORD KIT
• Three-foot power cord WITHOUT LCDI
• 4-pin connector
• Low-voltage personality plug on 20 amp and 30 amp kits
• Only for use in 230/208 volt sub-bases with new AZ45/65 units
• Requires the purchase of RAK4002D
junction box
Kit No.
RAK315SP
Volts
Heater
Wattage
Circuit
Ampacity
230/208 2.4/1.96 kw 15
RAK320SP 230/208 3.4/2.8 kw 20
RAK330SP 230/208 4.8/3.99 kw 30
RAK515P/520P/530P†
RAK520P shown
265 VOLTS UNIVERSAL POWER
SUPPLY
• Three-foot power cord WITHOUT LCDI
• 4-pin connector
• Low-voltage personality plug on 20 amp and 30 amp kits
• Only for use in 265 volt sub-bases with new AZ45/65 units
Kit No.
RAK515P
RAK520P
RAK530P
Volts
Heater
Wattage
265 2.4 kw
Circuit
Ampacity
15
265
265
3.4 kw
4.8 kw
20
30
RAK315D/320D/330D†
RAK320D shown
230/208-VOLT DIRECT CONNECT
POWER SUPPLY KIT
• 4-pin connector with three 7" 12-gauge conductor wires and low-voltage personality plug on 20 amp and 30 amp kits
• Requires the purchase of RAK4002D junction box
Kit No.
RAK315D
RAK320D
RAK330D
Volts
Heater
Wattage
Circuit
Ampacity
230/208 2.4/1.99 kw 15
230/208
230/208
3.4/2.8 kw
4.8/3.99 kw
20
30
RAK515D/520D/530D†
RAK520D shown
265-VOLT UNIVERSAL DIRECT
CONNECT POWER SUPPLY KIT
• 4-pin connector with three 7" 12-gauge conductor wires and low-voltage personality plug on 20 amp and 30 amp kits
Kit No.
RAK515D
RAK520D
RAK530D
Volts
Heater
Wattage
265 2.4 kw
Circuit
Ampacity
15
265
265
3.4 kw
4.8 kw
20
30
†Heater wattage may vary slightly among models. 30-amp heater wattage is reduced in low fan operation.
VISIT ZONELINE.COM OR CALL 888.231.2548
13
14
ZONELINE® ACCESSORIES REPLACEMENT PARTS
(FOR AZ45-AZ65 SERIES)
RAK4002D
DIRECT-CONNECT JUNCTION BOX WIRING
(230/208 & 265 VOLTS)
• Kit for direct connection of 230/208-volt and
265-volt units to building power supply (via sub base or direct connect)
• Junction box is included
on 265-volt units
• Used on models ending
in W5 or higher
(made after April 2019)
RAK13
MERV 13 MAKEUP AIR FILTER KIT
• When required by code for Makeup Air Products
(California 01-01-2020)
• Includes one filter
• Replacement filter RAA13 sold separately
RAA64
REPLACEMENT FILTERS
• One pair per box
• Sold in pairs
• Conveniently accessible through
the front of the unit
RAKCDC
CDC WIRING CONNECTOR
• 3-wire connector
• Works with Central Desk Control system and through wall fan option
• External fan option
• For use with DBM/EBM Makeup Air units
and approved occupancy sensing thermostats
SHCM10PK
SmartHQ TM HOME CONNECT MODULE – 10 PACK
• Single module shown — sold in packs of 10
• Connects to unit and uses local non-captive
Wi-Fi network.
• Provides individual remote control or Remote
fleet management through SmartHQ management
• Allows for site error notifications
• Receive and install software updates
For full features visit www.smarthqsolutions.com
VISIT ZONELINE.COM OR CALL 888.231.2548
ZONELINE® THERMOSTATS
RAK149F2
• Two fan speed Dual use Digital thermostat
- Can be set up for Single or Two stage heat
(AZ45 or AZ65)
• 24V AC wired remote wall thermostat
• Heat pump configured as default
• Requires 6-wire hookup for single stage heat
and 7-wires for two stage heat
RAK149P2
• Programmable Dual use Digital thermostat
- Can be set up for Single or Two stage heat
(AZ45 or AZ65)
• Programmable for 7-day or 5+2-day programs
• 24V AC wired remote wall thermostat
• Heat pump configured as default
• Requires 5-wire hookup for single stage heat
and 6-wires for two stage heat
RAK180W1
ENERGY MANAGEMENT OCCUPANCY
SENSING WIRED/WIRELESS THERMOSTAT
MAKEUP AIR COMPATIBLE
• 2-wire power connection available
(all other signals wireless)
• Thermostat (shown) and control card
(mounts under Zoneline cover) included
• Control card works off 24 Volt AC or DC signal
from unit
• Works with single-stage cooling and single-stage
or two-stage heating systems with proper set up.
Default is two stage heating and B type heat pump
• Extra 24V relay for controlling GE Zoneline
Makeup Air duct door when room is unoccupied
for additional energy savings
• Output may be programmed to control other room
systems such as lighting, vents, etc.
RAK160W2
WIRELESS THERMOSTAT WITH TWO FAN SPEEDS
• 2–wire power connection optional
(all other signals are wireless)
• Thermostat (shown) – Also comes with
control card that mounts on unit.
• Works off 24 Volt AC signal from unit
• Works with single stage cooling and either
signal stage or two-stage heating. Default is
two-stage heating and B-type heat pump
WALL THERMOSTAT
When installed with a remote Thermostat, the PTAC special feature display illuminates automatically a message
(Use Wall Thermostat). The LED will dim down after a few seconds and then turn off after a few minutes as to not disturb the guest in a dark room.
Additional thermostat options are available for specialty lighting and energy management applications.
Contact your GEA rep for more details.
VISIT ZONELINE.COM OR CALL 888.231.2548
15
ZONELINE® ACCESSORIES
RETROFIT KITS FOR OLDER ZONELINES
• Cut-off Assembly with LED module
• Main board with additional relay & software
• Junction box with power supply
& status LED light
• Plug and play harnesses
• Ground Wire
PTAC IEQ Kit Offerings:
RAKUVC1 (compatible for 230/208V models) and RAKUVC2 (compatible with 265V models) are available for order. These kits are customized to retrofit your Zoneline® PTAC (Z45/65 only
W5 and higher ). The IEQ kits are specifically designed for our Zoneline PTACs and do not void the warranty of your PTAC after installation.
Average 93.9% reduction of airborne viruses within 180 minutes.*
Power
Voltage
Description Kits
Module
SmartHQ Capable
Warranty
RAKUVC1
10 Watts
208/230V
UV-C LED kit for AZ45/65
12 cluster of 4 LED’s
YES
1 Year, Parts only
RAKUVC2
10 Watts
265V
UV-C LED kit for AZ45/65
12 cluster of 4 LED’s
YES
1 Year, Parts only
16
NUMBER
RAA62
RAA62A
RAA63
RAA64
RAB78B
RAB81
RAB81B
RAB8116B
RAB8118B
RAB8120B
RAB8124B
RAD10
RAF452
RAF452A
RAF453A
RAF454
RAG60
RAG61
RAG62
RAG63
RAG67
RAK40
RAK44
RAK4002A
RAK4002B
RAK4002C
RAK4002CW
RAK4002D
DESCRIPTION
Replacement filters for AZ models (10 pairs per box) for 22, 32 & 52 only
Replacement filters (10 pairs per box) for 25, 35 & 55 only
Replacement filters (10 pairs per box) for 28, 38, 41, 58, & 61 only
Replacement filters (one pair per box) for 45 & 65 only (while supplies last). Will be available from
Parts - WP85X20858
SMC four piece Quick Snap wall sleeve
Wall Sleeve-ships flat- 4 piece snap together 42x16x13 3/4
Wall Sleeve-fully assembled 4 piece snap together 42x16x13 3/4
Quick Snap Wall Sleeve 16" extended depth
Quick Snap Wall Sleeve 18" extended depth
Quick Snap Wall Sleeve 20" extended depth
Quick Snap Wall Sleeve 24" extended depth
Internal/external drain kit
Replacement room cabinet (2-position louvers) for 22, 32 & 52 only
Replacement room cabinet (2-position louvers) for 25, 35 & 55 only
Replacement room cabinet (2-position louvers) for 28, 29, 38, 39, 41, 58 and 61 only
Replacement room cabinet (2-position louvers) for 45 & 65 only
Stamped aluminum exterior rear grille
Architectural rear grille, beige
Architectural rear grille, maple
Architectural rear grille, dark brown
Aluminum architectural outdoor grille
Air deflector kit
PTAC Curtain Guard (5 Pack)
Direct-connect junction box 230/208V for 25, 35, 28, 29, 38, 39, 41, 45, 61 & 65 only
Direct-connect junction box 230/208V for 55, 58 only
Direct-connect junction box, 230/208V and 265V for 45 & 65 Models ending in W4 or lower
Direct-connect junction box wiring, 230/208V and 265V (excludes 45 & 65)
Direct-connect junction box 230/208V for 45 & 65 models ending in W5 or higher
*GE Appliances tested a Phi-X174 bacteriophage virus, nebulized in a sealed test chamber (10´x 10´x 10´(1000 ft 3)) with an average temperature of 68° F and relative humidity of 50.3%. Air sampling was taken every 30 minutes with the Zoneline PTAC on high speed with a new UVC kit active over 3 hours & compared to natural decay results. Testing was conducted at a nationally accredited laboratory.
VISIT ZONELINE.COM OR CALL 888.231.2548
ZONELINE® ACCESSORIES
NUMBER
RAK315P
RAK320P
RAK330P
RAK315D
RAK320D
RAK330D
RAK515D
RAK520D
RAK530D
RAK315SP
RAK320SP
RAK330SP
RAK515P
RAK520P
RAK530P
RAK205CW
RAK204D15C
RAK204D20C
RAK204D30C
RAK204E15C
RAK204E20C
RAK204E30C
RAK204U
RAK601B
RAK602B
RAK6052
RAK6053
RAK7013
RAK7023
RAK8023
RAK806
RAK901L
RAKCDC
RAA13
RAK13
RAKUVC1
RAKUVC2
SHCM10PK
DESCRIPTION
Universal power supply, 15 amp for 45 & 65 only with 6' power cord
Universal power supply, 20 amp for 45 & 65 only with 6' power cord
Universal power supply, 30 amp for 45 & 65 only with 6' power cord
230/208V Universal power supply, 15 amp for 45 & 65 only
230/208V Universal power supply, 20 amp for 45 & 65 only
230/208V Universal power supply, 30 amp for 45 & 65 only
265V Universal power supply, short 15 amp for 45 & 65 only
265V Universal power supply, short 20 amp for 45 & 65 only
265V Universal power supply, short 30 amp for 45 & 65 only
230/208V Universal power supply, short, 15 amp for 45 & 65 only, 3' cord for sub-base use only
230/208V Universal power supply, short, 20 amp for 45 & 65 only, 3' cord for sub-base use only
230/208V Universal power supply, short, 30 amp for 45 & 65 only, 3' cord for sub-base use only
265V Universal power supply, 15 amp for 45 & 65 only, 3' cord for sub-base use only
265V Universal power supply, 20 amp for 45 & 65 only, 3' cord for sub-base use only
265V Universal power supply, 30 amp for 45 & 65 only, 3' cord for sub-base use only
Chaseway for RAK204U sub-base
230/208V, 15 amp sub-base with power cord, 45 & 65 only
230/208V, 20 amp sub-base with power cord, 45 & 65 only
230/208V, 30 amp sub-base with power cord, 45 & 65 only
265V, 15 amp sub-base with power cord, 45 & 65 only
265V, 20 amp sub-base with power cord, 45 & 65 only
265V, 30 amp sub-base with power cord, 45 & 65 only
Sub-base without electrical devices or wiring
Duct extension for 45 & 65 only (Includes RAK602B)
Air register and trim flange for 45 & 65 only
Duct adapter for 22, 32, 25, 35, 28, 29, 38, 39, 41 & 61 only (Color prior to AZ45/65 Series)
Duct adapter for new installations 45 & 65 only
Duct adapter AZ45/65 with existing ductwork measuring 8 3/8" H x 6 1/2" W
Duct transition for replacement of new units and existing ductwork measuring 7 3/32" x 6 1/2" W for 45 & 65 only
Locking door kit for 28, 29, 38, 39, 41, 58 & 61 only
Universal cover label (10 covers per kit), excludes 45 & 65
Wall case insulation kit (While supplies last)
CDC Wiring Connector for 45 & 65 only (Also used with occupancy thermostats for Makeup Air)
Replacement filter for RAK13
MERV 13 filter kit for Makeup Air models (California 1-1-2020)
Add on 230/208 volt UVC retrofit kit for AZ45/65 series ending in W5 or higher
Add on 265 volt UVC retrofit kit for AZ45/65 series ending in W5 or higher
SmartHQ TM Home Connect Module (10 pack)
THERMOSTATS
NUMBER DESCRIPTION
RAK149F2
RAK149P2
Single stage and two stage digital 2 fan speed remote thermostat
Single stage and two stage programmable remote thermostat
RAK160W2
RAK180W1
Wireless two fan speed thermostat
Energy management/occupancy sensing wireless thermostat – Makeup Air compatible
VISIT ZONELINE.COM OR CALL 888.231.2548
17
ZONELINE® PACKAGED TERMINAL AIR CONDITIONER SPECIFICATIONS
AZ45 SERIES 230V/208V
AZ45 series (typical) cooling with electric heat
230/208V Models
Cooling BTUH
AZ45E07DAB AZ45E09DAB AZ45E12DAB AZ45E15DAB
7,200/7,000 9,700/9,600 11,600/11,500 14,200/14,100
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)*
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
13.4/13.4
1.64
R-410A
350
220
33
96%
72%
535/520
2.5/2.6
13.5
12.1/12.1
2.7
R-410A
390
260
38
98%
64%
800/790
3.6/3.9
21.0
11.7/11.8
3.5
R-410A
420
290
38
98%
62%
960/900
4.7/5.0
29.5
10.5/10.5
4.6
R-410A
435
330
47
97%
63%
1,350/1,320
6.2/6.6
31.5
Weight (Net/Ship) 90/100 103/113 106/116 106/116
AZ45 series cooling with electric heat (Dry Air 25)
230/208V Models
Cooling BTUH
AZ45E07DAP
6,900/6,800
AZ45E09DAP
9,400/9,300
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant Type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)*
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Total Cooling Amperes, F.L.
12.8/12.8
2.4
R-410A
350
220
40.0
96%
59%
535/530
2.5/2.7
12.1/12.1
3.4
R-410A
370
260
44.0
97%
58%
775/765
3.5/3.8
Amperes, L.R.
Weight (Net/Ship)
13.5
96/106
21.0
109/119
AZ45E12DAP
11,200/11,100
11.4/11.5
4.2
R-410A
360
270
44
98%
54%
970/960
4.4/4.7
29.5
112/122
AZ45 series cooling with electric heat
(Corrosion Protection)
230/208V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)*
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
AZ45E07DAC AZ45E09DAC AZ45E12DAC AZ45E15DAC
7,200/7,000 9,400/9,300 11,600/11,500 14,000/13,900
13.4/13.4
1.64
R-410A
350
220
33
96%
11.8/11.8
2.7
R-410A
390
260
38
98%
11.7/11.8
3.5
R-410A
420
290
38
98%
10.3/10.4
4.6
R-410A
435
330
47
97%
72%
535/520
2.5/2.6
13.5
90/100
64%
795/790
3.5/3.9
21
103/113
62%
985/955
4.4/4.7
29.5
106/116
63%
1,350/1,330
6.2/6.6
31.5
106/116
AZ45 series cooling with electric heat (Makeup Air)
230/208V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
AZ45E09DBM
9,100/9,100
11.5/11.5
2.4
R-410A
350
220
25-50
98%
75%
790/790
5.1/5.2
21.0
122/132
AZ45E12DBM
11,700/11,500
11.6/11.6
3.3
R-410A
390
240
25-50
98%
69%
1,005/985
4.5/4.9
29.5
123/133
Specifications subject to change.
NOTE: Resistance heater wattage and amperage dependent on power connection kit. See page 8.
*Using RAKVENT1 kit
Listed by
Underwriters
Laboratories
VISIT ZONELINE.COM OR CALL 888.231.2548
18
ZONELINE® PACKAGED TERMINAL AIR CONDITIONER SPECIFICATIONS
AZ65 SERIES 230V/208V
AZ65 series heat pump with backup electric heat
230/208V Models
Cooling BTUH
AZ65H07DAB AZ65H09DAB AZ65H12DAB AZ65H15DAB
7,100/6,900 9,700/9,600 11,900/11,800 14,400/14,200
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)*
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
13.0/13.0
1.7
R-410A
360
205
38
96%
79%
545/530
2.5/2.7
13.5
12.2/12.2
2.6
R-410A
420
300
40
98%
68%
795/785
3.6/3.8
21.0
11.6/11.8
3.7
R-410A
410
300
45
98%
10.5/10.5
4.8
R-410A
400
290
44
97%
62% 60%
1,020/995 1,365/1,340
4.6/4.9
29.5
6.2/6.6
31.5
Reverse cycle heat BTUH
Coefficient of Performance
Heat Pump Watts
Heat Pump Amperes
Weight (Net/Ship)
6,200/6,100
4.0/4.0
450/440
2.1/2.2
98/108
8,100/8,000 10,400/10,300 13,500/13,300
3.7/3.7
3.6/3.6
3.2/3.2
645/630
3.0/3.2
104/114
845/835
3.8/4.0
104/114
1,195/1,160
5.4/5.7
107/117
AZ65 series heat pump with backup electric heat
(Internal Condensate Removal)
230/208V Models
Cooling BTUH
AZ65H07DAD AZ65H09DAD AZ65H12DAD AZ65H15DAD
7,000/6,900 9,600/9,500 11,800/11,600 14,100/14,100
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)*
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heat Pump Watts
Heat Pump Amperes
Weight (Net/Ship)
13.0/13.0
1.6
R-410A
360
205
38.0
96%
73%
535/530
2.5/2.7
13.5
6,200/6,000
4.0/4.0
450/435
2.1/2.2
100/110
12.0/12.0
2.6
R-410A
420
300
40.0
98%
11.5/11.5
3.7
R-410A
410
300
45.0
98%
10.3/10.3
4.8
R-410A
400
290
44.0
97%
68%
800/790
3.6/3.9
21.0
62%
1,020/1,005
4.5 /4.9
29.5
60%
1,385/1,360
6.1/6.6
31.5
8,200/8,000 10,400/10,200 13,200/13,000
3.6/3.6
3.5/3.5
3.2/3.2
665/650
3.0/3.2
108/118
870/850
3.8/4.0
106/116
1,235/1,225
5.3/5.6
110/120
AZ65 (typical) series heat pump with backup electric heat
(Corrosion Protection)
230/208V Models
Cooling BTUH
AZ65H07DAC AZ65H09DAC AZ65H12DAC AZ65H15DAC
7,100/7,000 9,600/9,500 11,800/11,600 14,400/14,200
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)*
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heat Pump Watts
Heat Pump Amperes
Weight (Net/Ship)
13.0/13.0
1.6
R-410A
360
205
38
96%
73%
545/535
2.5/2.7
13.5
6,200/6,100
4.0/4.0
450/445
2.1/2.2
98/108
12.2/12.2
2.6
R-410A
420
300
40
98%
68%
795/785
3.6/3.9
21.0
8,100/8,000
3.7/3.7
645/630
2.9/3.1
106/116
11.8/11.8
3.7
R-410A
410
300
45
98%
10.4/10.4
4.8
R-410A
400
290
44
97%
62%
995/975
4.5/4.9
29.5
60%
1,365/1,365
6.2/6.7
31.5
10,300/10,200 13,200/13,000
3.6/3.6
3.2/3.2
835/815
3.8/4.0
104/114
1,205/1,180
5.5/5.8
108/118
AZ65 series heat pump with backup electric heat (Makeup Air)
230/208V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heat Pump Watts
Heat Pump Amperes
Weight (Net/Ship)
AZ65H07DBM AZ65H09DBM AZ65H12DBM AZ65H15DBM
7,000/7,000
12.5/12.5
0.9
R-410A
360
205
25-50
96%
9,200/9,100
11.3/11.3
1.9
R-410A
420
300
25-50
97%
11,500/11,400 14,000/13,800
11.2/11.2
10.1/10.1
2.9
R-410A
410
300
4.3
R-410A
400
290
25-50
97%
25-50
97%
89%
560/560
3.7/3.9
13.5
6,200/6,100
4.0/4.0
450/440
3.3/3.4
117/127
80%
810/805
4.9/5.2
21.0
73%
1,025/1,015
5.8/6.2
29.5
66%
1370/1350
6.2/6.6
31.5
8,000/7,900 10,200/10,000 13,200/13,000
3.3/3.3
3.5/3.5
3.2/3.2
705/695
4.7/4.8
123/133
850/835
5.0/5.2
123/133
1200/1180
5.4/5.7
126/136
VISIT ZONELINE.COM OR CALL 888.231.2548
19
20
ZONELINE® PACKAGED TERMINAL AIR CONDITIONERS SPECIFICATIONS
AZ45 SERIES 265V
AZ45 series cooling with electric heat (Corrosion Protection)
265V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)*
Power factor
Sensible heat ratio
@ 265 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
Weight (Net/Ship)
AZ45E07EAC AZ45E09EAC AZ45E12EAC AZ45E15EAC
7,100
13.2
1.64
R-410A
350
220
33
95%
72%
540
2.2
11.7
95/105
9,500
11.6
2.7
R-410A
393
260
38
94%
67%
815
3.3
16.5
103/113
11,500
11.7
3.5
R-410A
420
290
38
97%
62%
990
4.0
23.5
106/116
14,700
10.5
4.6
R-410A
435
330
47
97%
63%
1,390
5.5
29.0
107/117
AZ65 SERIES 265V
AZ65 (typical) series heat pump with backup electric heat
(Corrosion Protection)
265V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)*
Power factor
Sensible heat ratio
@ 265 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heat Pump Watts
Heat Pump Amperes
Weight (Net/Ship)
AZ65H07EAC AZ65H09EAC AZ65H12EAC AZ65H15EAC
7,000
12.8
9,500
11.7
11,500
11.2
14,000
10.0
1.5
R-410A
360
205
38
95%
2.5
R-410A
420
300
40
94%
3.7
R-410A
410
300
45
97%
4.8
R-410A
400
290
44
97%
77%
545
2.2
11.7
6,200
3.9
460
1.9
98/108
68%
810
3.3
16.5
8,100
3.6
655
2.8
104/114
62%
1,025
4.0
23.5
10,000
3.5
835
3.5
104/114
60%
1,390
5.5
29.0
13,200
3.1
1,225
4.9
109/119
AZ45 series cooling with electric heat (Dry Air 25)
265V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
AZ45E09EAP
9,400
12.1
3.5
R-410A
370
260
Vent CFM (full open)*
Power factor
Sensible heat ratio
@ 265 volts
Cooling Watts
Total Cooling Amperes, F.L.
Heating Amperes
Weight (Net/Ship)
44
93%
58%
780
3.2
16.5
109/119
AZ45E12EAP
10,900
11.0
4.2
R-410A
360
270
44
97%
54%
995
3.9
23.5
112/122
AZ65 series heat pump with backup electric heat
(Internal Condensate Removal)
265V Models
Cooling BTUH
AZ65H07EAD AZ65H09EAD AZ65H12EAD AZ65H15EAD
7,000 9,500 11,600 14,200
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM (full open)*
Power factor
Sensible heat ratio
@ 265 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heat Pump Watts
Heat Pump Amperes
Weight (Net/Ship)
12.8
1.5
R-410A
360
205
38
95%
77%
545
2.2
11.7
6,200
3.9
460
1.9
100/110
11.7
2.5
R-410A
420
300
40
94%
68%
810
3.3
16.5
8,100
3.5
670
2.8
106/116
11.4
3.7
R-410A
410
300
45
97%
62%
1,015
4.1
23.5
10,000
3.4
850
3.5
106/116
10.3
4.8
R-410A
400
290
44
97%
60%
1,375
5.5
29.0
13,300
3.2
1,210
4.9
111/121
Specifications subject to change.
NOTE: Resistance heater wattage and amperage dependent on power connection kit. See page 8.
*Using RAKVENT1 kit
AZ65 series heat pump with backup electric heat (Makeup Air)
265V Models
Cooling BTUH
EER (BTU/Watt)
Dehumidification Pts/Hr
Refrigerant type
CFM, indoor fan high
CFM, indoor fan low
Vent CFM
Power factor
Sensible heat ratio
@ 230 volts
Cooling Watts
Total Cooling Amperes, F.L.
Amperes, L.R.
Reverse cycle heat BTUH
Coefficient of Performance
Heat Pump Watts
Heat Pump Amperes
Weight (Net/Ship)
AZ65H07EBM
6,900
12.5
0.7
R-410A
360
205
25-50
93%
88%
550
3.2
11.7
6,000
3.9
450
2.9
117/127
AZ65H09EBM
9,200
11.5
2.0
R-410A
420
360
25-50
93%
78%
800
4.2
16.5
8,100
3.6
655
3.8
123/133
AZ65H12EBM
11,600
11.3
2.8
R-410A
410
300
25-50
96%
72%
1,025
4.0
23.5
10,000
3.4
860
3.5
123/133
Listed by
Underwriters
Laboratories
VISIT ZONELINE.COM OR CALL 888.231.2548
HOW TO ORDER
It’s easy to order Zoneline, and Zoneline Parts & Accessories
Call or go online to get the products, parts and accessories you need from GE Appliances.
ZONELINE.COM
| GEAPPLIANCES.COM
| GEAPPLIANCEPARTS.COM
| 844.GE4.PTAC – GE FACTORY SERVICE
ORDER GE APPLIANCES PARTS DIRECT
When you order GE Appliances Parts direct, you’ll be backed by quality and support you can count on:
• Original genuine parts
• Limited 1-year warranty
• Discounts and promotions
• Access to illustrated parts catalog
• Check status and availability
Apply for credit, speak to a GE Appliances Parts
Specialist or buy genuine GE Appliances Parts at:
GECUSTOMERNET.COM
|
800.851.6200
YOUR PRODUCT INFORMATION:
Locate your Zoneline’s serial number:
• Remove cover
• Find the base pan, located at the bottom of the unit
• Serial number will be printed on the base pan
MY ACCOUNT NUMBER
MY SALES MANAGER
CONTACT US FOR A QUOTE TODAY:
888.231.2548
[email protected]
VISIT ZONELINE.COM OR CALL 888.231.2548
21
ZONELINE® WARRANTY
FOR THE PERIOD OF
ONE YEAR
From the date of the original purchase
GE APPLIANCES WILL REPLACE
Any part of the air conditioner which fails due to a defect in materials or workmanship.
During this limited one-year warranty, GE will provide, free of charge, all labor and related service costs to replace the defective part.
FIVE YEARS
From the date of the original purchase
SECOND THROUGH
FIFTH YEAR
From the date of the original purchase
Sealed Refrigerating System – if any part of the Sealed Refrigerating System
(the compressor, condenser, evaporator, and all connecting tubing, including the makeup air system) should fail due to a defect in materials or workmanship. During this limited five-year warranty, GE will provide, free of charge, all labor and related service costs to replace the defective part.
Fan Motors, Switches, Heater, Heater Protectors, Compressor Overload, Solenoids, Circuit
Boards, Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls, ICR Pump,
Capacitors, Varistors and Indoor Blower Bearing, if any of these parts should fail due to a defect in materials or workmanship. During this additional four-year limited warranty, GE will provide the replacement part free of charge. The customer will be responsible for any labor and related service costs.
22
ZONELINE® CHASSIS NOMENCLATURE
A Z 6 5 H 1 2 D A D
Zoneline
Chassis series
45=cool/electric heat
65= heat pump
Nominal cooling capacity
07=7,000 BTUh cooling
09=9,000 BTUh cooling
12=12,000 BTUh cooling
15=15,000 BTUh cooling
A = universal power connection
B = Digital Makeup
Air module with universal power connection
Unit type
E= cooling with electric resistance heat
H= heat pump with electric resistance heat backup
Voltage/Phase/Frequency
D= 230/208 Volt, single phase, 60 Hz
E= 265 Volt, single phase,
60 Hz
Special features
B =Base unit
C = Corrosion Protection
D = Internal Condensate
Removal (ICR) system (AZ65 only)
M =Makeup Air
P =Dry Air 25 (AZ45 only)
Visit Zoneline.com for more information.
Listed by
Underwriters
Laboratories
VISIT ZONELINE.COM OR CALL 888.231.2548
NOTES
VISIT ZONELINE.COM OR CALL 888.231.2548
23
GE is a trademark of the General Electric Company.
Manufactured under trademark license.
Appliance Park
Louisville, KY 40225 zoneline.com
Pub No. 20-S0424-22
OTGEA22283
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- High energy efficiency rating for reduced operating costs
- Quiet operation for a peaceful indoor environment
- Electronic temperature limiting to prevent overheating or overcooling
- Remote thermostat capability for convenient temperature control
- Works with central desk control for centralized management
- Corrosion protection for use in coastal areas
Related manuals
Frequently Answers and Questions
1. What is the cooling capacity of the GE AZ65H12DAB?
2. Does the GE AZ65H12DAB have a digital display?
3. Can the GE AZ65H12DAB be controlled remotely?
4. Is the GE AZ65H12DAB energy efficient?
5. How quiet is the GE AZ65H12DAB?
advertisement