Juniper M10i Hardware Guide
Advertisement
Advertisement
M10i Multiservice Edge Router Hardware Guide
Modified: 2019-01-04
Copyright © 2019, Juniper Networks, Inc.
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, California 94089
USA
408-745-2000 www.juniper.net
Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc. in the United States and other countries. All other trademarks, service marks, registered marks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
M10i Multiservice Edge Router Hardware Guide
Copyright © 2018 Juniper Networks, Inc. All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at https://support.juniper.net/support/eula/ . By downloading, installing or using such software, you agree to the terms and conditions of that EULA.
ii Copyright © 2019, Juniper Networks, Inc.
Table of Contents
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . xxii
Creating a Service Request with JTAC . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiii
M10i Packet Forwarding Engine Architecture Overview . . . . . . . . . . . . . . . . . . . . . . 5
Data Flow Through the Packet Forwarding Engine . . . . . . . . . . . . . . . . . . . . . . 5
Chassis Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
M10i High-Availability Chassis Manager (HCM) Description . . . . . . . . . . . . . . . . . 14
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 19
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 21
Copyright © 2019, Juniper Networks, Inc.
iii
M10i Multiservice Edge Router Hardware Guide
MX5, MX10, MX40, and MX80 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . 37
MX2020 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
PTX10008 and PTX10016 Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TX Matrix Plus (with 3D SIBs) Routing Engines . . . . . . . . . . . . . . . . . . . . . . . 50
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 63
iv Copyright © 2019, Juniper Networks, Inc.
Table of Contents
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 67
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact
Forwarding Engine Board (CFEB-E) Description . . . . . . . . . . . . . . . . . . . . . . . 67
Site Planning, Preparation, and Specifications
Clearance Requirements for Airflow and Hardware Maintenance . . . . . . . . . . . . . 79
M10i Chassis Grounding Cable and Lug Specifications . . . . . . . . . . . . . . . . . . . . . . 81
AC Power Requirements and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 85
DC Power Requirements and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Network Cable and Transceiver Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Attenuation and Dispersion in Fiber-Optic Cable on M Series, MX Series, and T
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable for M10i
Calculating Power Budget for Fiber-Optic Cable for M Series, MX Series, and T
Calculating Power Margin for Fiber-Optic Cable for M Series, MX Series, and T
Management Cable and Transceiver Specifications and Pinouts . . . . . . . . 99
Routing Engine Interface Cable and Wire Specifications for M10i Routers . . . . . . 99
RJ-45 Connector Pinouts for the M10i Routing Engine MGMT Port . . . . . . . . . . . 100
DB-9 Connector Pinouts for the M10i Routing Engine AUX/MODEM and CONSOLE
Initial Installation and Configuration
Copyright © 2019, Juniper Networks, Inc.
v
M10i Multiservice Edge Router Hardware Guide vi
Tools and Parts Required to Unpack the M10i Router . . . . . . . . . . . . . . . . . . . . . . 107
Tools and Parts Required to Install the M10i Router Into a Rack . . . . . . . . . . . . . . 111
Connecting the M10i Router to a Network for Out-of-Band Management . . . . . . 119
Connecting to an M10I Management Console or Auxiliary Device . . . . . . . . . . . . 120
Tools and Parts Required to Connect the M10i Router to External Devices . . . . . 123
Connecting Power on an AC-Powered M10i Router . . . . . . . . . . . . . . . . . . . . . . . . 123
Connecting Power on an DC-Powered M10i Router . . . . . . . . . . . . . . . . . . . . . . . 125
Installing and Replacing Components
Overview of Installing and Replacing Components . . . . . . . . . . . . . . . . . . . 139
Tools and Parts Required to Replace M10i Hardware Components . . . . . . . . . . . 140
Replacing Cooling System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Copyright © 2019, Juniper Networks, Inc.
Table of Contents
Installing the CompactFlash Card in an M10i Routing Engine . . . . . . . . . . . . . . . . 155
Configuring the CompactFlash Card on an M10i Routing Engine . . . . . . . . . . . . . 156
Installing an SDRAM Module in an M10i Routing Engine . . . . . . . . . . . . . . . . . . . . 157
Removing the M10i Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Removing and Inserting the PC Card from an M10i Routing Engine . . . . . . . . . . . 162
Removing the PC Card from an M10i Routing Engine . . . . . . . . . . . . . . . . . . 163
Inserting the PC Card in an M10i Routing Engine . . . . . . . . . . . . . . . . . . . . . . 164
Replacing the CompactFlash Card in an M10i Routing Engine . . . . . . . . . . . . . . . 165
Removing the CompactFlash Card from an M10i Routing Engine . . . . . . . . . 165
Installing the CompactFlash Card in an M10i Routing Engine . . . . . . . . . . . . 166
Replacing an SDRAM Module on an M10i Routing Engine . . . . . . . . . . . . . . . . . . 167
Removing an SDRAM Module from an M10i Routing Engine . . . . . . . . . . . . . 167
Installing an SDRAM Module in an M10i Routing Engine . . . . . . . . . . . . . . . . 168
Replacing the SSD on an RE-B-1800 Routing Engine . . . . . . . . . . . . . . . . . . . . . 169
Replacing an M10i Ethernet Management Cable . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Removing a Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Installing a Management Ethernet Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Removing an M10i Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . . 172
Installing an M10i Console or Auxiliary Cable . . . . . . . . . . . . . . . . . . . . . . . . . 172
Replacing Power System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Removing an M10i AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
Removing an M10i AC Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Removing an M10i DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Copyright © 2019, Juniper Networks, Inc.
vii
M10i Multiservice Edge Router Hardware Guide
Disconnecting Power on an AC-Powered M10i Router . . . . . . . . . . . . . . . . . . . . . 208
Disconnecting Power on an DC-Powered M10i Router . . . . . . . . . . . . . . . . . . . . 209
Replacing Switch Fabric Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Replacing, Upgrading, or Downgrading an M10i CFEB or CFEB-E . . . . . . . . . . . . . 212
Removing an M10i CFEB or CFEB-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Upgrading or Downgrading an M10i CFEB or CFEB-E . . . . . . . . . . . . . . . . . . 215
Maintaining the Chassis and Components
Routine Maintenance Procedures for the M10i Router . . . . . . . . . . . . . . . . . . . . . 219
M10i Hardware and Interface Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
Troubleshooting the M10i Power System When LEDs on All Power Supplies
Troubleshooting the M10i Power System When the LED on One Power
Troubleshooting the M10i Power System When LEDs on All Power Supplies Are
Troubleshooting the M10i Power System When the LED on One Power Supply
Contacting Customer Support and Returning the Chassis or
viii Copyright © 2019, Juniper Networks, Inc.
Table of Contents
Locating Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Displaying M10i Router Components and Serial Numbers . . . . . . . . . . . . . . . . . . 247
M10i CFEB and CFEB-E Serial Number ID Label . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Packing and Returning Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Returning a Hardware Component to Juniper Networks, Inc. . . . . . . . . . . . . . . . . 253
Tools and Parts Required to Remove Components from an M10i Router . . . . . . 254
Guidelines for Packing M10i Components for Shipment . . . . . . . . . . . . . . . . . . . 256
General Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
General Safety Guidelines for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . 261
General Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . . 262
Preventing Electrostatic Discharge Damage to an M10i Router . . . . . . . . . . . . . . 264
Fire Safety Requirements for Juniper Networks Devices . . . . . . . . . . . . . . . . . . . . 267
Installation Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . 269
Installation Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . . . . . . 269
Rack-Mounting Requirements and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . 271
Laser and LED Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . 277
Radiation from Open Port Apertures Warning . . . . . . . . . . . . . . . . . . . . . . . . 279
Maintenance and Operational Safety Guidelines and Warnings . . . . . . . . 281
Maintenance and Operational Safety Warnings for Juniper Networks Devices . . 281
Copyright © 2019, Juniper Networks, Inc.
ix
M10i Multiservice Edge Router Hardware Guide
Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . 287
General Electrical Safety Warnings for Juniper Networks Devices . . . . . . . . . . . . 287
Grounding Requirements and Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
Midplane Energy Hazard Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
Multiple Power Supplies Disconnection Warning . . . . . . . . . . . . . . . . . . . . . 289
General Electrical Safety Guidelines and Electrical Codes for M10i Routers . . . . 291
Japanese AC Power Cord Warning for M Series and MX Series Routers . . . . . . . 292
DC Power Electrical Safety Warnings for Juniper Networks Devices . . . . . . . . . . 293
DC Power Copper Conductors Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
DC Power Disconnection Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
DC Power Wiring Terminations Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Agency Approvals and Compliance Statements . . . . . . . . . . . . . . . . . . . . . 299
Compliance Statements for EMC Requirements for Juniper Networks Devices
Compliance Statements for EMC Requirements for M10i Routers (European
Compliance Statements for EMC Requirements for Juniper Networks Devices
Compliance Statements for EMC Requirements for Juniper Networks Devices
Compliance Statements for EMC Requirements for Juniper Networks Devices
Compliance Statements for Environmental Requirements . . . . . . . . . . . . . . . . . 302
Compliance Statements for Acoustic Noise for M10i Routers . . . . . . . . . . . . . . . 302
Statements of Volatility for Juniper Network Devices . . . . . . . . . . . . . . . . . . . . . 303
x Copyright © 2019, Juniper Networks, Inc.
List of Figures
Figure 2: Packet Forwarding Engine Components and Data Flow . . . . . . . . . . . . . . 6
Figure 4: Control Packet Handling for Routing and Forwarding Table
Chassis Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 19
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 21
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 63
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 67
Site Planning, Preparation, and Specifications
Figure 21: Chassis Dimensions and Clearance Requirements . . . . . . . . . . . . . . . . 80
Figure 22: Grounding Cable and Grounding Points . . . . . . . . . . . . . . . . . . . . . . . . . 82
AC Power Requirements and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Copyright © 2019, Juniper Networks, Inc.
xi
M10i Multiservice Edge Router Hardware Guide xii
DC Power Requirements and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Initial Installation and Configuration
Figure 26: Moving the Mounting Brackets on the Chassis . . . . . . . . . . . . . . . . . . . 112
Figure 27: Installing the Chassis into a Open-Frame Rack . . . . . . . . . . . . . . . . . . . 114
Figure 30: Routing Engine Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . . 120
Figure 32: Console and Auxiliary Serial Port Connector . . . . . . . . . . . . . . . . . . . . . 121
Figure 35: Connecting DC Power Cables to a DC Power Supply . . . . . . . . . . . . . . 127
Installing and Replacing Components
Figure 36: Installing the Cable Management System . . . . . . . . . . . . . . . . . . . . . . 141
Replacing Cooling System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Copyright © 2019, Juniper Networks, Inc.
List of Figures
Figure 58: Routing Engine Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . . 171
Figure 63: Small Form-Factor Pluggable (SFP) . . . . . . . . . . . . . . . . . . . . . . . . . . 178
Figure 66: Connecting Fiber-Optic Cable to a PIC . . . . . . . . . . . . . . . . . . . . . . . . 186
Figure 67: Small Form-Factor Pluggable (SFP) . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Figure 68: Small Form-Factor Pluggable (SFP) . . . . . . . . . . . . . . . . . . . . . . . . . . 190
Replacing Power System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Figure 71: Connecting DC Power Cables to a DC Power Supply . . . . . . . . . . . . . . 195
Figure 76: Connecting DC Power Cables to a DC Power Supply . . . . . . . . . . . . . 205
Replacing Switch Fabric Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Contacting Customer Support and Returning the Chassis or
Locating Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Figure 83: Routing Engine Serial Number ID Label . . . . . . . . . . . . . . . . . . . . . . . . 250
Figure 85: Power Supply Serial Number ID Label . . . . . . . . . . . . . . . . . . . . . . . . . 251
Figure 86: CFEB or CBEF-E Serial Number ID Label . . . . . . . . . . . . . . . . . . . . . . . 252
General Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Figure 87: Placing a Component into an Electrostatic Bag . . . . . . . . . . . . . . . . . 264
Copyright © 2019, Juniper Networks, Inc.
xiii
M10i Multiservice Edge Router Hardware Guide xiv Copyright © 2019, Juniper Networks, Inc.
List of Tables
Chassis Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 21
Table 15: MX5, MX10, MX40, and MX80 Routing Engine . . . . . . . . . . . . . . . . . . . . 38
Table 18: MX480 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 19: MX960 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 20: MX2008 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 22: MX2020 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Table 23: MX10003 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Table 28: PTX10008 and PTX10016 Routing Engines . . . . . . . . . . . . . . . . . . . . . . 46
Copyright © 2019, Juniper Networks, Inc.
xv
M10i Multiservice Edge Router Hardware Guide xvi
Table 35: Routing Engines on TX Matrix Plus with 3D SIBs . . . . . . . . . . . . . . . . . . 50
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Table 37: End-of-Life PICs Supported in the M10i Router . . . . . . . . . . . . . . . . . . . 56
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 63
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 67
Site Planning, Preparation, and Specifications
Table 43: M10i Router Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . 80
AC Power Requirements and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Table 45: Electrical Specifications for AC Power Supply . . . . . . . . . . . . . . . . . . . . 85
DC Power Requirements and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Table 47: Electrical Specifications for DC Power Supply . . . . . . . . . . . . . . . . . . . . 89
Network Cable and Transceiver Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Table 48: Estimated Values for Factors Causing Link Loss . . . . . . . . . . . . . . . . . . 96
Management Cable and Transceiver Specifications and Pinouts . . . . . . . . 99
Table 49: Cable Specifications for Routing Engine Management Ports . . . . . . . . 99
Initial Installation and Configuration
Installing and Replacing Components
Overview of Installing and Replacing Components . . . . . . . . . . . . . . . . . . . 139
Copyright © 2019, Juniper Networks, Inc.
List of Tables
Table 59: SONET/SDH Interface Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . . 236
Copyright © 2019, Juniper Networks, Inc.
xvii
M10i Multiservice Edge Router Hardware Guide xviii Copyright © 2019, Juniper Networks, Inc.
About the Documentation
•
Documentation and Release Notes on page xix
•
Documentation Conventions on page xix
•
Documentation Feedback on page xxi
•
Requesting Technical Support on page xxii
Documentation and Release Notes
To obtain the most current version of all Juniper Networks
® technical documentation, see the product documentation page on the Juniper Networks website at https://www.juniper.net/documentation/ .
If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
Juniper Networks Books publishes books by Juniper Networks engineers and subject matter experts. These books go beyond the technical documentation to explore the nuances of network architecture, deployment, and administration. The current list can be viewed at https://www.juniper.net/books .
Documentation Conventions
defines notice icons used in this guide.
Copyright © 2019, Juniper Networks, Inc.
xix
M10i Multiservice Edge Router Hardware Guide
Table 1: Notice Icons
Icon Meaning
Informational note
Caution
Warning
Laser warning
Tip
Best practice
Description
Indicates important features or instructions.
Indicates a situation that might result in loss of data or hardware damage.
Alerts you to the risk of personal injury or death.
Alerts you to the risk of personal injury from a laser.
Indicates helpful information.
Alerts you to a recommended use or implementation.
defines the text and syntax conventions used in this guide.
Table 2: Text and Syntax Conventions
Convention Description Examples
Bold text like this
Fixed-width text like this
Represents text that you type.
Represents output that appears on the terminal screen.
To enter configuration mode, type the configure command: user@host> configure user@host> show chassis alarms
No alarms currently active
Italic text like this
Italic text like this
•
•
• Introduces or emphasizes important new terms.
Identifies guide names.
Identifies RFC and Internet draft titles.
•
•
•
A policy term is a named structure that defines match conditions and actions.
Junos OS CLI User Guide
RFC 1997, BGP Communities Attribute
Represents variables (options for which you substitute a value) in commands or configuration statements.
Configure the machine’s domain name:
[edit] root@# set system domain-name domain-name xx Copyright © 2019, Juniper Networks, Inc.
About the Documentation
Table 2: Text and Syntax Conventions (continued)
Convention Description
Text like this
< > (angle brackets)
| (pipe symbol)
Examples
Represents names of configuration statements, commands, files, and directories; configuration hierarchy levels; or labels on routing platform components.
•
•
To configure a stub area, include the stub statement at the [edit protocols ospf area area-id] hierarchy level.
The console port is labeled CONSOLE .
Encloses optional keywords or variables.
stub <default-metric metric >;
Indicates a choice between the mutually exclusive keywords or variables on either side of the symbol. The set of choices is often enclosed in parentheses for clarity.
broadcast | multicast
( string1 | string2 | string3 )
# (pound sign)
[ ] (square brackets)
Indention and braces ( { } )
; (semicolon)
Indicates a comment specified on the same line as the configuration statement to which it applies.
rsvp { # Required for dynamic MPLS only
Encloses a variable for which you can substitute one or more values.
Identifies a level in the configuration hierarchy.
Identifies a leaf statement at a configuration hierarchy level.
community name members [ community-ids ]
[edit] routing-options { static { route default { nexthop address; retain;
}
}
}
GUI Conventions
Bold text like this
> (bold right angle bracket)
Represents graphical user interface (GUI) items you click or select.
•
•
In the Logical Interfaces box, select
All Interfaces .
To cancel the configuration, click
Cancel .
Separates levels in a hierarchy of menu selections.
In the configuration editor hierarchy, select Protocols>Ospf .
Documentation Feedback
We encourage you to provide feedback so that we can improve our documentation. You can use either of the following methods:
• Online feedback system—Click TechLibrary Feedback, on the lower right of any page on the Juniper Networks TechLibrary site, and do one of the following:
Copyright © 2019, Juniper Networks, Inc.
xxi
M10i Multiservice Edge Router Hardware Guide
• Click the thumbs-up icon if the information on the page was helpful to you.
• Click the thumbs-down icon if the information on the page was not helpful to you or if you have suggestions for improvement, and use the pop-up form to provide feedback.
• E-mail—Send your comments to [email protected]
. Include the document or topic name, URL or page number, and software version (if applicable).
Requesting Technical Support
Technical product support is available through the Juniper Networks Technical Assistance
Center (JTAC). If you are a customer with an active J-Care or Partner Support Service support contract, or are covered under warranty, and need post-sales technical support, you can access our tools and resources online or open a case with JTAC.
• JTAC policies—For a complete understanding of our JTAC procedures and policies, review the JTAC User Guide located at https://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf
.
• Product warranties—For product warranty information, visit https://www.juniper.net/support/warranty/ .
• JTAC hours of operation—The JTAC centers have resources available 24 hours a day,
7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features:
• Find CSC offerings: https://www.juniper.net/customers/support/
• Search for known bugs: https://prsearch.juniper.net/
• Find product documentation: https://www.juniper.net/documentation/
• Find solutions and answer questions using our Knowledge Base: https://kb.juniper.net/
• Download the latest versions of software and review release notes: https://www.juniper.net/customers/csc/software/
• Search technical bulletins for relevant hardware and software notifications: https://kb.juniper.net/InfoCenter/ xxii Copyright © 2019, Juniper Networks, Inc.
About the Documentation
• Join and participate in the Juniper Networks Community Forum: https://www.juniper.net/company/communities/
• Create a service request online: https://myjuniper.juniper.net
To verify service entitlement by product serial number, use our Serial Number Entitlement
(SNE) Tool: https://entitlementsearch.juniper.net/entitlementsearch/
Creating a Service Request with JTAC
You can create a service request with JTAC on the Web or by telephone.
• Visit https://myjuniper.juniper.net
.
• Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
For international or direct-dial options in countries without toll-free numbers, see https://support.juniper.net/support/requesting-support/ .
Copyright © 2019, Juniper Networks, Inc.
xxiii
M10i Multiservice Edge Router Hardware Guide xxiv Copyright © 2019, Juniper Networks, Inc.
PART 1
Overview
•
System Overview and Architecture on page 3
•
M10i Router Release Notes on page 9
•
Chassis Components and Descriptions on page 11
•
Cooling System Components and Descriptions on page 19
•
Host Subsystem Components and Descriptions on page 21
•
Line Card Components and Descriptions on page 51
•
Power System Components and Descriptions on page 63
•
Switch Fabric Components and Descriptions on page 67
Copyright © 2019, Juniper Networks, Inc.
1
M10i Multiservice Edge Router Hardware Guide
2 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 1
System Overview and Architecture
•
M10i Router Description on page 3
•
M10i System Redundancy on page 4
•
M10i System Architecture Overview on page 4
•
M10i Packet Forwarding Engine Architecture Overview on page 5
•
M10i Routing Engine Architecture Overview on page 7
M10i Router Description
The M10i Multiservice Edge Router provides high-speed interfaces for medium and large networks and network applications, such as those supported by Internet service providers
(ISPs). Application-specific integrated circuits (ASICs), a definitive part of the router design, enable the router to forward data at the high speeds demanded by current network media.
The M10i router supports up to eight Physical Interface Cards (PICs). The router height of 8.7 in. (22.1 cm) enables stacked installation of five M10i routers in a single floor-to-ceiling rack, for increased port density per unit of floor space.
The router’s maximum aggregate throughput is 12.8 gigabits per second (Gbps) simplex or 6.4 Gbps full duplex. Inserting a combination of PICs with an aggregate higher than the maximum throughput per FPC is supported, but constitutes oversubscription of the
FPC.
The router architecture cleanly separates control operations from packet forwarding operations, which helps to eliminate processing and traffic bottlenecks. Control operations in the router are performed by the Routing Engine, which runs Junos OS to handle routing protocols, traffic engineering, policy, policing, monitoring, and configuration management.
Forwarding operations in the router are performed by the Packet Forwarding Engine, which consists of hardware, including ASICs, designed by Juniper Networks.
Related
Documentation
•
M10i System Redundancy on page 4
•
M10i Chassis Description on page 11
•
M10i Router Physical Specifications on page 76
•
Overview of M10i Router Installation on page 105
Copyright © 2019, Juniper Networks, Inc.
3
M10i Multiservice Edge Router Hardware Guide
M10i System Redundancy
You can configure the router for system redundancy by using three AC or four DC load-sharing, fully-redundant power supplies to distribute power to the other components.
AC System Redundancy
AC system redundancy requires three independent AC power outlets. If one power supply fails, the other two power supplies provide full power to the router's components indefinitely.
You can set up increased AC system redundancy by using four AC power supplies. In this case, two power supplies are powered from two AC outlets, and the other two power supplies use two AC outlets from a UPS battery-backed power source. This lets the router run during AC power outages for the amount of time that the UPS allows.
DC System Redundancy
DC system redundancy requires two power sources from feed A and two power sources from feed B. If one feed fails or is shut down for service, the other feed powers two DC power supplies and can provide full power to the router's components indefinitely.
Related
Documentation
•
M10i Chassis Description on page 11
•
M10i Router Physical Specifications on page 76
•
Overview of M10i Router Installation on page 105
M10i System Architecture Overview
The router architecture consists of two major components:
• Packet Forwarding Engine—Performs Layer 2 and Layer 3 packet switching, route lookups, and packet forwarding.
• Routing Engine—Provides Layer 3 routing services and network management.
The Packet Forwarding Engine and the Routing Engine perform independently but communicate constantly through a 100-Mbps internal link. This arrangement provides streamlined forwarding and routing control and the ability to run Internet-scale networks at high speeds.
illustrates the relationship between the Packet
Forwarding Engine and the Routing Engine.
4 Copyright © 2019, Juniper Networks, Inc.
Chapter 1: System Overview and Architecture
Figure 1: System Architecture
Related
Documentation
•
M10i Chassis Description on page 11
•
M10i Midplane Description on page 12
•
M10i Power System Description on page 63
M10i Packet Forwarding Engine Architecture Overview
The Packet Forwarding Engine performs Layer 2 and Layer 3 packet switching. It can forward up to 15 million packets per second (Mpps) for all packet sizes. The aggregate throughput is 4 gigabits per second (Gbps) full duplex per FPC (8 Gbps full-duplex total throughput rate). The Packet Forwarding Engine is implemented in application-specific integrated circuits (ASICs). It uses a centralized route lookup engine and shared memory.
The Packet Forwarding Engine architecture includes the following components:
• Midplane—Transports packets, notifications, and other signals between the PICs and the Packet Forwarding Engine (as well as other system components).
• Physical Interface Card (PIC)—Physically connects the router to fiber-optic or digital network media. A controller ASIC in each PIC performs control functions specific to the PIC media type.
• Compact Forwarding Engine Board (CFEB) or Enhanced Compact Forwarding Engine
Board (CFEB-E)—Hosts an integrated ASIC, which makes forwarding decisions, distributes data cells to the shared memory, and directs data packets when they are ready for transmission.
Data Flow Through the Packet Forwarding Engine
Use of ASICs promotes efficient movement of data packets through the system. Packets flow through the Packet Forwarding Engine in the following sequence (see
):
1.
Packets arrive at an incoming networking interface.
2.
The networking interface passes the packets to the CFEB or CFEB-E, where the integrated ASIC processes the packet headers, divides the packets into 64-byte data cells, and distributes the data cells throughout the memory buffer.
Copyright © 2019, Juniper Networks, Inc.
5
M10i Multiservice Edge Router Hardware Guide
3.
The integrated ASIC on the CFEB or CFEB-E performs a route lookup for each packet and decides how to forward it.
a.
If services are configured for the packet, the integrated ASIC reassembles the packet and passes them to the services interface.
b.
The services interface passes the packet to the CFEB or CFEB-E, where the integrated ASIC processes the packet, divides the packet into 64-byte cells, and distributes the data cells throughout the memory buffer.
c.
The integrated ASIC performs a second route lookup for each packet and decides how to forward it.
4.
The integrated ASIC notifies the outbound networking interface.
5.
The integrated ASIC reassembles data cells stored in shared memory into data packets as they are ready for transmission and passes them to the outbound networking interface.
6.
The outbound networking interface transmits the data packets.
Figure 2: Packet Forwarding Engine Components and Data Flow
6
Related
Documentation
•
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description on page 67
•
M10i Router Description on page 3
•
M10i Router Physical Specifications on page 76
Copyright © 2019, Juniper Networks, Inc.
Chapter 1: System Overview and Architecture
M10i Routing Engine Architecture Overview
The Routing Engine is an Intel-based PCI platform running the Junos OS, which Juniper
Networks has developed and optimized to handle large numbers of network interfaces and routes. The software consists of a set of system processes running in protected memory modules on top of an independent operating system. The Junos kernel supports
Junos system processes, which handle system management processes, routing protocols, and control functions (see
The Routing Engine has a dedicated 100-Mbps internal connection to the Packet
Forwarding Engine.
Figure 3: Routing Engine Architecture
Routing Engine Functions
The Routing Engine handles all routing protocol processes, as well as the software processes that control the router's interfaces, the chassis components, system management, and user access to the router. These routing and software processes run on top of a kernel that interacts with the Packet Forwarding Engine. For more information about the processes, see the CLI Explorer .
The Routing Engine includes the following functions and features:
• Processing of routing protocol packets—The Routing Engine handles all packets that concern routing protocols, freeing the Packet Forwarding Engine to handle only packets that represent Internet traffic.
• Software modularity—Because each software process is devoted to a different function and uses a separate process space, the failure of one process has little or no effect on the others.
• In-depth Internet functionality—Each routing protocol is implemented with a complete set of Internet features and provides full flexibility for advertising, filtering, and modifying routes. Routing policies are set according to route parameters (for example, prefix, prefix lengths, and Border Gateway Protocol [BGP] attributes).
Copyright © 2019, Juniper Networks, Inc.
7
M10i Multiservice Edge Router Hardware Guide
• Scalability—The Junos routing tables have been designed to hold all the routes in current networks with ample capacity for expansion. Additionally, the Junos OS can efficiently support large numbers of interfaces and virtual circuits.
• Management interface—Different levels of system management tools are provided, including the Junos OS command-line interface (CLI), the Junos XML management protocol, the craft interface, and SNMP.
• Storage and change management—Configuration files, system images, and microcode can be held and maintained in primary and secondary storage systems, permitting local or remote upgrades.
• Monitoring efficiency and flexibility—The router supports functions such as alarm handling and packet counting on every port, without degrading packet-forwarding performance.
The Routing Engine constructs and maintains one or more routing tables (see
). From the routing tables, the Routing Engine derives a table of active routes, called the forwarding table, which is then copied into the Packet Forwarding
Engine. The design of the ASICs allow the forwarding table in the Packet Forwarding
Engine to be updated without interrupting forwarding performance.
Figure 4: Control Packet Handling for Routing and Forwarding Table Updates
8
Related
Documentation
•
M10i Routing Engine Description on page 21
•
Maintaining the M10i Routing Engine on page 222
•
Replacing the M10i Routing Engine on page 158
Copyright © 2019, Juniper Networks, Inc.
CHAPTER 2
M10i Router Release Notes
•
Outstanding Issues with the M10i Router on page 9
•
Errata with the M10i Router Documentation on page 9
Outstanding Issues with the M10i Router
This section lists outstanding issues with the documentation.
• The default configuration of the Routing Engine does not include an CompactFlash card, which affects which media are available to the Routing Engine as it accesses the
Junos operating system (Junos OS) at boot time. For more information about the
Routing Engine’s use of boot media, see “Installation Overview” in the Junos OS
Administration Library .
• The long haul (LH) small form-factor pluggable transceiver (SFP) conforms to Class
A emissions standards on the M10i router when it is installed in the 1-port Gigabit
Ethernet SFP Physical Interface Card (PIC).
Related
Documentation
•
Errata with the M10i Router Documentation on page 9
•
M10i Routing Engine Description on page 21
Errata with the M10i Router Documentation
There are currently no outstanding issues for the M10i router documentation.
Related
Documentation
•
Outstanding Issues with the M10i Router on page 9
Copyright © 2019, Juniper Networks, Inc.
9
M10i Multiservice Edge Router Hardware Guide
10 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 3
Chassis Components and Descriptions
•
M10i Chassis Description on page 11
•
M10i Midplane Description on page 12
•
M10i Cable Management System Description on page 13
•
M10i High-Availability Chassis Manager (HCM) Description on page 14
•
•
M10i HCM Alarm LEDs on page 16
M10i Chassis Description
The router chassis is a rigid sheet metal structure that houses the other hardware components. The chassis is 17.5 in. (44.5 cm) wide and 18 in. (45.7 cm) deep. The chassis height of 8.7 in. (22.1 cm) enables stacked installation of eight M10i routers in a single floor-to-ceiling rack. For more information, see
“Installation Safety Warnings for Juniper
.
The two mounting brackets (one on each side) extend the chassis width to 19 in.
(48.3 cm).
and
show front and rear views of the router chassis.
Figure 5: Front of Chassis
Copyright © 2019, Juniper Networks, Inc.
11
M10i Multiservice Edge Router Hardware Guide
Figure 6: Rear of Chassis
Engine Boards
Grounding points optional feature optional feature
P/S 3
P/S 2
C-FEB 0
C-FEB 1
P/S 1
P/S 0
NOTE: A MINIMUM
BE PRESENT
TWO POWER
FOR NORMAL
TION.
MUST
Primary fan tray
Power supplies Redundant fan tray
The chassis includes an electrostatic discharge (ESD) point (banana plug receptacle) to protect electronic components from damage due to static electricity, at the front of the chassis, as shown in
.
WARNING: Before removing or installing components of a functioning router, attach an ESD strap to an ESD point and place the other end of the strap around your bare wrist. Failure to use an ESD strap could result in damage to the router.
The router must be connected to earth ground during normal operation.
For chassis serial number information , see
“Displaying M10i Router Components and
Related
Documentation
•
M10i System Redundancy on page 4
•
M10i Router Physical Specifications on page 76
•
Overview of M10i Router Installation on page 105
M10i Midplane Description
The midplane is a panel located in the center of the chassis, running from side to side and forming the rear of the PIC card cage (see
Figure 7 on page 13 ). All router components
plug directly into the midplane. The midplane contains an EEPROM that stores the serial number and revision level of the midplane.
The midplane performs the following functions:
• Transfer of packets—After being processed by a PIC, an incoming data packet crosses the midplane to the CFEB or the CFEB-E. The CFEB or CFEB-E performs switching and
12 Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions forwarding functions and transfers outgoing packets back across the midplane to the
PICs for transmission to the network.
• Power distribution—The midplane distributes power to all router components from the power supplies attached to it. It also provides hot-plug protection for the PIC and
HCM slots.
• Signal connectivity—The midplane transports the signals exchanged by system components for monitoring and control purposes.
Figure 7: Midplane
For chassis serial number information , see
“Displaying M10i Router Components and
Related
Documentation
•
M10i Chassis Description on page 11
•
M10i Router Description on page 3
•
General Electrical Safety Warnings for Juniper Networks Devices on page 287
M10i Cable Management System Description
The cable management system consists of racks that attach vertically to each side of the chassis at the front, as shown in
Figure 8 on page 14 . Pass PIC cables through the
slots in the racks to keep the cables organized and securely in place, and to avoid bending optical cables beyond the proper bend radius. The cable management system evenly distributes the weight of a cable, so that it is not subjected to undue stress at the connector.
Copyright © 2019, Juniper Networks, Inc.
13
M10i Multiservice Edge Router Hardware Guide
Figure 8: Cable Management System
Related
Documentation
•
Installing the M10i Cable Management System on page 141
•
M10i Chassis Description on page 11
•
M10i Router Physical Specifications on page 76
M10i High-Availability Chassis Manager (HCM) Description
The High-Availability Chassis Manager (HCM) works with its companion Routing Engine to provide control and monitoring functions for router components. The HCM also displays alarm status and takes PICs online and offline.
Two HCMs are installed into the midplane from the front of the chassis, as shown in
. The master HCM performs all functions and provides PIC removal buttons for the first FPC. The backup HCM provides PIC removal buttons for the second
FPC. The HCM in the slot labeled HCM0 is paired with the Routing Engine in the slot labeled RE0 . Likewise, the HCM in the slot labeled HCM1 is paired with the Routing Engine in the slot labeled RE1 . By default, the HCM in the slot labeled HCM0 is the master.
NOTE: When HCM mastership changes because of failure, Routing Engine mastership will change as well. For a description of Routing Engine mastership, see
“M10i Routing Engine Description” on page 21
.
The HCM performs the following functions:
• Monitoring and control of router components—The HCM collects statistics from all sensors in the system. When it detects a failure or alarm condition, it sends a signal to the Routing Engine, which generates control messages or sets an alarm. The HCM also relays control messages from the Routing Engine to the router components.
• Controlling component power-up and power-down—The HCM controls the power-up sequence of router components as they start and powers down components when their offline buttons are pressed.
14 Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
• Signaling of mastership—In a router with more than one Routing Engine, the HCM signals to all router components which Routing Engine is the master and which is the standby.
• Alarm display—If an alarm exists, the HCM displays the alarm condition. For more information, see
“M10i HCM Alarm LEDs” on page 16 .
• PIC removal—If a PIC offline button is pressed, the HCM relays the request to the CFEB or CFEB-E, which takes the PIC offline and informs the Routing Engine. Other PICs are unaffected, and system operation continues. For more information, see
.
Figure 9: M10i High-Availability Chassis Manager
Each HCM (shown in
Figure 9 on page 15 ) has the following components:
• 100-Mbps Fast Ethernet switch—Carries signals and monitoring data between router components.
• Two LEDs—Indicate HCM status. There is a green one labeled PWR and an blue one labeled MSTR .
describes the LED states.
• Alarm LEDs—Display alarm conditions, if any exist.
• PIC offline buttons—Relays a request to the CFEB or CFEB-E, which prepares a PIC for removal from the router, or brings the PIC online when it is replaced.
Offline buttons for one row of PICs are located on each HCM (see
Pressing the button relays a request to the CFEB or CFEB-E, which prepares the PIC for removal from the router, or brings it online when it is replaced. The HCM in slot 0 controls PICs on FPC 0 . The HCM in slot 1 controls PICs on FPC 1 . The buttons are labeled with the PIC slot numbers. The PIC slots on the upper FPC are numbered from
0/0 (zero/zero) through 0/3 , right to left. The PIC slots in the lower FPC are numbered from 1/0 (one/zero) through 1/3 , right to left.
For PIC replacement instructions, see
“Replacing an M10i PIC” on page 179 .
Related
Documentation
•
M10i HCM Serial Number ID Label on page 248
•
M10i Router Physical Specifications on page 76
•
M10i Routing Engine Interface Ports on page 29
Copyright © 2019, Juniper Networks, Inc.
15
M10i Multiservice Edge Router Hardware Guide
M10i HCM LEDs
Figure 10: M10i High-Availability Chassis Manager
Two LEDs Indicate HCM status. There is a green LED labeled PWR and an blue LED labeled
MSTR .
describes the LED states.
Table 3: States for HCM LEDs
Label Color State Description
PWR Green On steadily HCM is functioning normally.
MSTR Blue
Blinking
On steadily
HCM is starting up.
HCM is master.
Related
Documentation
•
M10i High-Availability Chassis Manager (HCM) Description on page 14
•
M10i HCM Alarm LEDs on page 16
•
M10i Chassis Description on page 11
M10i HCM Alarm LEDs
Two alarm LEDs are located on the right of the HCM (see
circular red LED lights to indicate a critical condition that can result in a system shutdown.
The triangular yellow LED lights to indicate a less severe condition that requires monitoring or maintenance. Both LEDs can be lit simultaneously.
To deactivate red and yellow alarms, you must clear the condition that caused the alarm.
describes the alarm LEDs in more detail.
16 Copyright © 2019, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Table 4: Alarm LEDs
Shape Color
Red
Yellow
State Description
On steadily Critical alarm LED—Indicates a critical condition that can cause the router to stop functioning, such as component removal, failure, or overheating.
On steadily Warning alarm LED—Indicates a serious but nonfatal error condition, such as a maintenance alert or a significant increase in component temperature.
Related
Documentation
•
M10i Chassis Description on page 11
•
M10i High-Availability Chassis Manager (HCM) Description on page 14
•
M10i HCM Serial Number ID Label on page 248
Copyright © 2019, Juniper Networks, Inc.
17
M10i Multiservice Edge Router Hardware Guide
18 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 4
Cooling System Components and
Descriptions
•
M10i Fan Tray Description on page 19
M10i Fan Tray Description
The fan trays installed along each side of the chassis draw room air into the chassis to maintain an acceptable operating temperature for the Routing Engine, PICs, CFEB or
CFEB-E, and other components. The router's cooling system consists of two fan trays, located along the left and right side of the chassis, that provide side-to-side cooling (see
Figure 11 on page 19 ). They connect directly to the router midplane. Each fan tray is a
single unit containing eight individually fault-tolerant fans. If a single fan fails, the remaining fans continue to function indefinitely. For proper airflow, the primary fan tray should be installed in slot 1 (the left slot looking at the chassis from the rear) and must be installed for proper cooling at all times. The redundant fan tray, if present, should be installed in slot 0 on the right. This fan tray provides additional cooling and redundancy.
Figure 11: Airflow Through the Chassis
The fan tray is hot-removable and hot-insertable, as described in
. For instructions on replacing it, see
Copyright © 2019, Juniper Networks, Inc.
19
M10i Multiservice Edge Router Hardware Guide
CAUTION: Do not remove both fan trays for more than one minute while the router is operating. The fans are the sole source of cooling, and the router can overheat when they are absent.
Related
Documentation
•
Installing an M10i Fan Tray on page 149
•
M10i Router Description on page 3
•
Maintaining the M10i Cooling System on page 221
•
Troubleshooting the M10i Fan Tray on page 230
20 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 5
Host Subsystem Components and
Descriptions
•
M10i Routing Engine Description on page 21
•
M10i Routing Engine 400 Description on page 23
•
M10i Routing Engine 400 LEDs on page 24
•
M10i Routing Engine 850 Description on page 25
•
M10i Routing Engine 850 LEDs on page 26
•
M10i Routing Engine RE-B-1800 Description on page 27
•
M10i Routing Engine 1800 LEDs on page 28
•
M10i Routing Engine Interface Ports on page 29
•
Routing Engine Specifications on page 29
•
Supported Routing Engines by Router on page 34
M10i Routing Engine Description
The Routing Engine runs Junos OS. The software processes that run on the Routing Engine maintain the routing tables, manage the routing protocols used on the router, control the router's interfaces, control some chassis components, and provide the interface for system management and user access to the router.
For a description of the Routing Engine's role in router architecture, see
Engine Architecture Overview” on page 7
.
NOTE: The M10i router supports the Routing Engine 400, Routing Engine
850, and Routing Engine 1800.
One or two Routing Engines can be installed into the midplane from the front of the chassis, as shown in
Figure 5 on page 11 . If two Routing Engines are installed, the
High-Availability Chassis Manager (HCM) determines which is the master and which is backup (in standby mode and so performs no functions). By default, the Routing Engine in the slot labeled RE0 is the master. To change the default master Routing Engine, include the appropriate [edit chassis redundancy routing-engine] statement in the
Copyright © 2019, Juniper Networks, Inc.
21
M10i Multiservice Edge Router Hardware Guide configuration, as described in the section about Routing Engine redundancy in the Junos
OS Administration Library .
NOTE: If two Routing Engines are installed, they must both be the same hardware model.
The Routing Engine is hot-pluggable, as described in
. If two Routing Engines are installed, removal or failure of the backup
Routing Engine does not affect router function. Removal or failure of the master Routing
Engine affects forwarding and routing based on the high availability configuration:
• Dual Routing Engines without any high availability features enabled—Traffic is interrupted while the Packet Forwarding Engine is reinitialized. All kernel and forwarding processes are restarted. When the switchover to the new master Routing Engine is complete, routing convergence takes place and traffic is resumed.
• Graceful Routing Engine switchover (GRES) is enabled—Graceful Routing Engine switchover preserves interface and kernel information. Traffic is not interrupted.
However, graceful Routing Engine switchover does not preserve the control plane.
Neighboring routers detect that the router has restarted and react to the event in a manner prescribed by individual routing protocol specifications. To preserve routing without interruption during a switchover, graceful Routing Engine switchover must be combined with nonstop active routing.
• Nonstop active routing is enabled (graceful Routing Engine switchover must be configured for nonstop active routing to be enabled)—Nonstop active routing supports
Routing Engine switchover without alerting peer nodes that a change has occurred.
Nonstop active routing uses the same infrastructure as graceful Routing Engine switchover to preserve interface and kernel information. However, nonstop active routing also preserves routing information and protocol sessions by running the routing protocol process (rpd) on both Routing Engines. In addition, nonstop active routing preserves TCP connections maintained in the kernel.
• Graceful restart is configured—Graceful restart provides extensions to routing protocols so that neighboring helper routers restore routing information to a restarting router.
These extensions signal neighboring routers about the graceful restart and prevent the neighbors from reacting to the router restart and from propagating the change in state to the network during the graceful restart period. Neighbors provide the routing information that enables the restarting router to stop and restart routing protocols without causing network reconvergence. Neighbors are required to support graceful restart. The routing protocol process (rpd) restarts. A graceful restart interval is required.
For certain protocols, a significant change in the network can cause graceful restart to stop.
If you do not configure graceful Routing Engine switchover, graceful restart, or nonstop active routing, you can configure automatic Routing Engine mastership failover. For information about configuring automatic mastership failover, see the Junos OS
Administration Library .
22 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
NOTE: Router performance might change if the backup Routing Engine's configuration differs from the former master's configuration. For the most predictable performance, configure the two Routing Engines identically, except for parameters unique to each Routing Engine.
NOTE: For information about configuring graceful Routing Engine switchover, graceful restart, and nonstop active routing, see the High Availability Feature
Guide.
NOTE: The first supported release for graceful Routing Engine switchover and nonstop active routing on the M10i router is Junos OS Release 6.1 and
Junos OS Release 8.4, respectively. However, for graceful Routing Engine switchover we recommend Junos OS Release 7.0 or later. Graceful restart software requirements are dependent on the routing protocols configured on the router. For the minimum software requirements for graceful restart, see the High Availability Feature Guide.
For replacement instructions, see
“Replacing the M10i Routing Engine” on page 158 .
Related
Documentation
•
M10i Router Description on page 3
•
M10i Router Physical Specifications on page 76
•
M10i Router Power Requirements on page 82
M10i Routing Engine 400 Description
The Routing Engine 400 has the following major components:
• CPU—Runs Junos OS to maintain the router's routing tables and routing protocols. It has a Pentium-class processor.
• SDRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• CompactFlash card—This drive is optional. If installed, it provides primary storage. It holds software images, configuration files, and microcode.
• Hard disk—If no CompactFlash card is installed, provides primary storage for software images, configuration files, and microcode. If a CompactFlash card is installed, the hard disk provides secondary storage for log files and memory dumps, and can reboot the system if the CompactFlash card fails.
• I2C/EEPROM—Stores the serial number of the Routing Engine.
Copyright © 2019, Juniper Networks, Inc.
23
M10i Multiservice Edge Router Hardware Guide
The faceplate of the Routing Engine 400 contains the following:
• PC card slot—Accepts a removable PC card, which stores software images for system upgrades.
• Interfaces for out-of-band management access—Provide information about
Routing Engine status to devices (console, laptop, or terminal server) that can be attached to access ports located on the Routing Engine.
• Reset button—Reboots the Routing Engine when pressed.
• Offline button—Powers down the Routing Engine when pressed.
• Thumbscrews—Secure the Routing Engine in the chassis.
• Four LEDs—A green LED labeled HDD , a blue LED labeled MASTER , a red LED labeled
FAIL , and a green LED labeled ONLINE indicate Routing Engine status.
The disk from which the router boots is called the primary boot device , and the other disk is the alternate boot device .
The boot sequence for the router:
• PC Card
• CompactFlash card
• Hard disk
NOTE: If the router boots from an alternate boot device, a yellow alarm lights the LED on the router’s craft interface.
M10i Routing Engine 400 LEDs
Four LEDs—A green LED labeled HDD , a blue LED labeled MASTER , a red LED labeled
FAIL , and a green LED labeled ONLINE indicate Routing Engine status.
describes the LED states.
Table 5: States for Routing Engine LEDs
Label Color State Description
Green Blinking There is read/write activity on the PC card.
HDD
MASTER
FAIL
ONLINE
Blue
Red
Green
On steadily Routing Engine is functioning as master.
On steadily Routing Engine is not operational.
On steadily Routing Engine is running normally.
Related
Documentation
•
Displaying M10i Router Components and Serial Numbers on page 247
24 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
•
•
M10i Router Physical Specifications on page 76
M10i Routing Engine 850 Description
NOTE: RE-850 routing engine is being replaced with RE-B-1800 from Junos
OS release 12.1. See the End-of-life (EOL) and End-of-sale (EOS) Notification
Policy and Procedures for the M10i products at https://www.juniper.net/support/eol/ . End of life (EOL) indicates that the product has been removed from the price list and is no longer available for purchase. End of support (EOS) indicates that no new support contracts are available on these products and the last contract will expire on the EOS date associated with each product. For more information about EOS or EOL products, see the product support notification (PSN) hardware end-of-life announcements. For PSN details for RE-850, see PSN-2011-09-369.
Figure 12: Routing Engine
The Routing Engine 850 has the following major components (see
• CPU—Runs Junos OS to maintain the router's routing tables and routing protocols. It has a Pentium-class processor.
• SDRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• CompactFlash card—Provides primary storage. It holds software images, configuration files, and microcode.
• Hard disk—Provides secondary storage for log files and memory dumps, and can reboot the system if the CompactFlash card fails.
• I2C/EEPROM—Stores the serial number of the Routing Engine.
Copyright © 2019, Juniper Networks, Inc.
25
M10i Multiservice Edge Router Hardware Guide
NOTE: For specific information about Routing Engine components (for example, the capacity of the hard drive), issue the show chassis routing-engine command.
The faceplate of the Routing Engine 850 contains the following:
• PC card slot—Accepts a removable PC card, which stores software images for system upgrades.
• Interfaces for out-of-band management access—Provide information about
Routing Engine status to devices (console, laptop, or terminal server) that can be attached to access ports located on the Routing Engine.
• Reset button—Reboots the Routing Engine when pressed.
• Offline button—Powers down the Routing Engine when pressed.
• Thumbscrews—Secure the Routing Engine in the chassis.
• Four LEDs—A green LED labeled HDD , a blue LED labeled MASTER , a red LED labeled
FAIL , and a green LED labeled ONLINE indicate Routing Engine status.
The disk from which the router boots is called the primary boot device , and the other disk is the alternate boot device .
The boot sequence for the router:
• PC Card
• CompactFlash card
• Hard disk
NOTE: If the router boots from an alternate boot device, a yellow alarm lights the LED on the router’s craft interface.
Related
Documentation
•
M10i Routing Engine 850 LEDs
Four LEDs—A green LED labeled HDD , a blue LED labeled MASTER , a red LED labeled
FAIL , and a green LED labeled ONLINE indicate Routing Engine status.
describes the LED states.
Table 6: States for Routing Engine LEDs
Label Color State Description
HDD Green Blinking There is read/write activity on the PC card.
26 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 6: States for Routing Engine LEDs (continued)
Label Color State Description
MASTER Blue
Red
On steadily Routing Engine is functioning as master.
On steadily Routing Engine is not operational.
FAIL
ONLINE Green On steadily Routing Engine is running normally.
Related
Documentation
•
Displaying M10i Router Components and Serial Numbers on page 247
•
M10i Router Physical Specifications on page 76
M10i Routing Engine RE-B-1800 Description
Figure 13: Routing Engine RE-B-1800
The Routing Engine RE-B-1800 has the following major components:
• CPU—Runs Junos OS to maintain the router's routing tables and routing protocols. It has Intel’s single core Jasper Forest processor.
• USB port—Provides a removable media interface through which you can install the
Junos OS manually. Junos OS supports USB version 2.0.
• DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• CompactFlash card—Provides primary storage for software images, configuration files, and microcode. The CompactFlash card is field-replaceable.
• Solid-state Disk (SSD)—Provides secondary storage for log files and memory dumps, and can reboot the system if the CompactFlash card fails. SSD is front-pluggable and hot-swappable.
• Interface ports—The AUX , CONSOLE , and MGMT ports provide access to management devices. Each Routing Engine has one 10/100/1000-Mbps Ethernet port for connecting to a management network, and two asynchronous serial ports—one for connecting to a console and one for connecting to a modem or other auxiliary device.
• EEPROM—Stores the serial number of the Routing Engine.
• Reset button—Reboots the Routing Engine when pressed.
• Online/Offline button—Takes the Routing Engine online or offline when pressed.
Copyright © 2019, Juniper Networks, Inc.
27
M10i Multiservice Edge Router Hardware Guide
• Real-time clock—Provides real-time integrated clock with batter backup for data retention.
• Extractor handle—Used for inserting and extracting the Routing Engine.
• Captive screws—Secure the Routing Engine in place.
• Four LEDs—A green LED labeled STORAGE , a blue LED labeled MASTER , a red LED labeled FAIL , and a green LED labeled ONLINE indicate Routing Engine status.
NOTE: For specific information about Routing Engine components (for example, the capacity of the SSD), issue the show chassis routing-engine command.
The router is shipped with the Junos OS preinstalled on the Routing Engine. There are three copies of software:
• One copy on the CompactFlash card in the Routing Engine.
• One copy on the SSD in the Routing Engine.
• One copy on a USB flash drive that can be inserted into the slot on the Routing Engine faceplate.
The Routing Engine boots from the storage media in this order: the USB device (if present), then the CompactFlash card, then the SSD, then the LAN. Normally, the router boots from the copy of the software on the CompactFlash card.
Related
Documentation
•
M10i Routing Engine 1800 LEDs on page 28
•
M10i Routing Engine Description on page 21
•
Replacing the M10i Routing Engine on page 158
•
Replacing the SSD on an RE-B-1800 Routing Engine on page 169
M10i Routing Engine 1800 LEDs
Four LEDs—a blue LED labeled MASTER , a red LED labeled FAIL , a green LED labeled
STORAGE , and a green LED labeled ONLINE —located on the faceplate, indicate Routing
Engine status.
describes the LED states.
Table 7: States for Routing Engine LEDs
Label Color State Description
Blue On steadily Routing Engine is functioning as master.
MASTER
FAIL
STORAGE
Red
Green
On steadily Routing Engine is not operational.
Blinking Indicates activity on the SSD or Compact Flash.
28 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 7: States for Routing Engine LEDs (continued)
Label Color State Description
ONLINE Green On steadily Routing Engine is running normally.
Related
Documentation
•
Displaying M10i Router Components and Serial Numbers on page 247
•
M10i Router Physical Specifications on page 76
M10i Routing Engine Interface Ports
Each Routing Engine has a set of ports for connecting to one or more external devices on which system administrators can issue Junos OS command-line interface (CLI) commands to manage the router (see
“M10i Routing Engine 850 LEDs” on page 25
).
The ports with the indicated label in each set function as follows:
• AUX/MODEM — Connects the Routing Engine to a laptop, modem, or other auxiliary device through an RS-232 (EIA-232) serial cable.
• MGMT —Connects the Routing Engine through an Ethernet connection to a management
LAN (or any other device that plugs into an Ethernet connection) for out-of-band management. The port uses an autosensing RJ-45 connector to support both 10- and
100-Mbps connections.
To the left of each MGMT port is a link status indicator, which lights to show that a link has been established over the Ethernet connection. To the right of each MGMT port is an activity indicator, which flashes when data is being transferred.
• CONSOLE —Connects the Routing Engine to a system console through an RS-232
(EIA-232) serial cable.
For information about the pinouts for the connectors, see
“RJ-45 Connector Pinouts for the M10i Routing Engine MGMT Port” on page 100 .
Related
Documentation
•
M10i Routing Engine Description on page 21
•
M10i Router Physical Specifications on page 76
•
M10i Routing Engine Architecture Overview on page 7
Routing Engine Specifications
lists the current specifications for Routing Engines supported on
M Series, MX Series, and T Series routers.
lists the specifications for end-of-life Routing Engines.
Copyright © 2019, Juniper Networks, Inc.
29
M10i Multiservice Edge Router Hardware Guide
NOTE: For a list of the routing engines that are supported on the M Series,
MX Series, T Series, and PTX routers, see
.
NOTE: For information about PTX Series Routing Engine specifications, see
Routing Engines Supported on PTX Series Routers. For information about
Table 8: Routing Engine Specifications
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-400-768 400-MHz
Celeron
768 MB Fast
Ethernet
RE-A-1000-2048 1.0-GHz
Pentium
RE-A-2000-4096 2.0-GHz
Pentium
RE-S-1300-2048 1.3-GHz
Pentium
2048 MB
4096 MB
2048 MB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Media
First Junos OS
Support
40 GB hard disk
1 GB
CompactFlash card
9.0
40 GB hard disk
1 GB
CompactFlash card
8.1
40 GB hard disk
1 GB
CompactFlash card
8.1
40 GB hard disk
1 GB
CompactFlash card
8.2
Switch Control
Board
–
–
–
SCB, SCBE
RE-S-2000-4096 2.0-GHz
Pentium
4096 MB Gigabit
Ethernet
40 GB hard disk
1 GB
CompactFlash card
8.2
SCB, SCBE
30 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 8: Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-C1800 1.8-GHz 8 GB Gigabit
Ethernet
RE-C2600
1.8 Ghz
2.6-GHz
16 GB
16 GB
Gigabit
Ethernet
Gigabit
Ethernet
RE-A-1800x2 1800-MHz 8 GB or 16
GB
Gigabit
Ethernet
RE-S-1800x2 1800-MHz 8 GB or 16
GB
Gigabit
Ethernet
Media
First Junos OS
Support
Switch Control
Board
SSD
SSD
SSD
4 GB
CompactFlash card
T1600 router in a routing matrix:
9.6R2
CB-T for a standalone router.
Standalone
T640 or T1600 router:11.2
CB-LCC for a router in a routing matrix.
4 GB
CompactFlash card
32-bit Junos OS on a standalone
T1600 router:
11.4R2 32-bit
Junos OS on a
T1600 router in a routing matrix:
11.4R2
CB-T for a standalone router.
CB-LCC for a router in a routing matrix.
64-bit Junos OS on a standalone
T1600 router:
11.4R2 64-bit
Junos OS on a
T1600 router in a routing matrix:
11.4R2
4 GB
CompactFlash card
TX Matrix Plus router: 9.6R2
–
– 32 GB SSD 4 GB
CompactFlash card
10.4
32 GB SSD 4 GB
CompactFlash card
10.4
SCB, SCBE
RE-S-1800x4 1800-MHz 8GB or 16
GB
Gigabit
Ethernet
RE-S-MX104 1.8-GHz
RE-B-1800x1-4G 1.73-GHz
4 GB
4 GB
Gigabit
Ethernet
Gigabit
Ethernet
32 GB SSD 4 GB
CompactFlash card
10.4
– 8 GB NAND
Flash
13.2
64 GB SSD 4 GB
CompactFlash card
12.1R2, 11.4R4, and 12.2R1
SCB, SCBE,
SCBE2
–
–
Copyright © 2019, Juniper Networks, Inc.
31
M10i Multiservice Edge Router Hardware Guide
Table 8: Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-MX2000-1800x4 1.8- GHz 16 GB Gigabit
Ethernet
RE-S-1800X4-32G-S 1.8- Ghz
REMX2K-1800-32G-S 1.8- Ghz
RE-S-X6-64G,
RE-S-X6-64G-LT
2 Ghz
REMX2K-X8-64G 2.3 Ghz
32 GB
32 GB
64 GB
64 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Media
First Junos OS
Support
Switch Control
Board
32 GB SSD 4 GB Fixed
Internal
CompactFlash card
12.3R2
32 GB SSD 4 GB Fixed
Internal
CompactFlash card
•
•
12.3R4
13.2R1
SCB, SCBE
SCB, SCBE
SCBE2
32 GB SSD 4GB Fixed
Internal
CompactFlash card
•
•
12.3R4
13.2R1
15.1F4, 16.1
Two 50-GB
SSDs
-
Two
100-GB
SSDs
15.1F5-S1, 16.1R2, and 16.2R1
–
SCBE2
–
REMX2K-X8-64G-LT 2.3 Ghz 64 GB Gigabit
Ethernet
17.2R1
–
REMX2008-X8-64G 2.3 Ghz
RE-S-1600x8 1.6 Ghz
REMX2008-X8-64G-LT 2.1 Ghz
REMX2008-X8-128G 2.3 Ghz
RE-S-X6-128G 2.1 Ghz
REMX2K-X8-128G 2.1 Ghz
JNP10003-RE1 1.6-GHz
64 GB
64 GB
64 GB
128 GB
128 GB
128 GB
64 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Two
100-GB
SSDs
-
Two 50-GB
SSDs
–
Two 50-GB
SSDs
–
Two
100-GB
SSDs
Two
200-GB
SSDs
-
Two
200-GB
SSDs
Two
200-GB
SSDs
Two 100
GB SSDs
-
-
-
15.1F7
17.3R1
17.2R1
18.2R1
18.1R1
18.1R1
17.3R1
–
–
-
-
-
-
-
32 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 8: Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk
JNP10003-RE1-LT 1.6-GHz 64 GB
JNP10K-RE0 2.5 GhZ
JNP10K-RE1 2.3 GhZ
JNP10K-RE1-LT 2.3 GhZ
JNP10K-RE1-128 2.3 GhZ
32 GB
64 GB
64 GB
128 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Media
Two 100
GB SSDs
-
Two 50 GB
SSDs
-
Two 200
GB SSDs
Two 200
GB SSDs
-
Two 200
GB SSDs
-
17.2R1
18.2R1
18.3R1
18.3R1
First Junos OS
Support
Switch Control
Board
18.1R1
-
-
-
-
-
NOTE: Use shielded CAT5e cable for connecting the AUX , CONSOLE , and
MGMT ports in RE-S-X6-64G, REMX2K-X8-64G, and REMX2008-X8-64G
Routing Engines.
Table 9: End-of-Life Routing Engine Specifications
Routing
Engine Processor Memory
Connection to PFEs Disk
RE-333-256 333-MHz
Pentium II
256 MB Fast
Ethernet
RE-333-768 333-MHz
Pentium II
768 MB Fast
Ethernet
Media
First Junos OS
Support
6.4 GB hard disk
80 MB
CompactFlash card
3.4
6.4 GB hard disk
80 MB
CompactFlash card
3.4
EOL Details
PSN-2003-01-063
PSN-2003-01-063
RE-600-512 600-MHz
Pentium III
512 MB
RE-600-2048 600-MHz
Pentium III
2048 MB
RE-850-1536 850-MHz
Pentium III
1536 MB
RE-M40 200-MHz
Pentium
256 MB
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
30 GB hard disk
256 MB
CompactFlash card
5.4
40 GB hard disk
1 GB
CompactFlash card
5.3
40 GB hard disk
1 GB
CompactFlash card
7.2
6.4 GB hard disk
80 MB
CompactFlash card
3.2
PSN-2004-07-019
PSN-2008-02-018
PSN-2011-04-226
FA-HW-0101-001
Copyright © 2019, Juniper Networks, Inc.
33
M10i Multiservice Edge Router Hardware Guide
Table 9: End-of-Life Routing Engine Specifications (continued)
Routing
Engine Processor Memory
Connection to PFEs Disk Media
RE-M40-333-768 333-MHz
Pentium II
768 MB Fast
Ethernet
RE-M40-600-2048 600-MHz
Pentium III
2048 MB
RE-1600-2048 1.6-GHz
Pentium M
2048 MB
Fast
Ethernet
Gigabit
Ethernet
First Junos OS
Support
10 GB hard disk
80 MB
CompactFlash card
4.2
30 GB hard disk
128 MB
CompactFlash card
5.4
40 GB hard disk
1 GB
CompactFlash card
6.2
EOL Details
PSN-2003-01-063
PSN-2004-11-020
PSN-2008-02-019
NOTE: The memory in
indicates the amount of total memory. To determine the amount of available memory, issue the show chassis routing-engine CLI command.
On routers that accept two Routing Engines, you cannot mix Routing Engine types except for a brief period (one minute or so) during an upgrade or downgrade to two Routing
Engines of the same type.
Related
Documentation
•
Supported Routing Engines by Router on page 34
Supported Routing Engines by Router
The following tables list the Routing Engines that each router supports, the first supported release for the Routing Engine in the specified router, the management Ethernet interface, and the internal Ethernet interfaces for each Routing Engine.
•
M7i Routing Engines on page 35
•
M10i Routing Engines on page 35
•
M40e Routing Engines on page 36
•
M120 Routing Engines on page 36
•
M320 Routing Engines on page 37
•
MX5, MX10, MX40, and MX80 Routing Engine on page 37
•
MX104 Routing Engines on page 38
•
MX240 Routing Engines on page 38
•
MX480 Routing Engines on page 39
•
MX960 Routing Engines on page 40
•
MX2008 Routing Engines on page 41
•
MX2010 Routing Engines on page 42
34 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
•
MX2020 Supported Routing Engines on page 42
•
MX10003 Routing Engines on page 43
•
MX10008 Routing Engines on page 43
•
PTX1000 Routing Engines on page 44
•
PTX3000 Routing Engines on page 44
•
PTX5000 Routing Engines on page 45
•
PTX10008 and PTX10016 Routing Engines on page 45
•
T320 Routing Engines on page 46
•
T640 Routing Engines on page 46
•
T1600 Routing Engines on page 47
•
T4000 Routing Engines on page 48
•
TX Matrix Routing Engines on page 49
•
TX Matrix Plus Routing Engines on page 49
•
TX Matrix Plus (with 3D SIBs) Routing Engines on page 50
M7i Routing Engines
lists the Routing Engines supported by the M7i router. The M7i router supports 32-bit Junos OS only.
Table 10: M7i Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-5.0
9.0
fxp0 fxp1 RE-400-768 (EOL details:
TSB16445 )
RE-850-1536 (EOL details:
TSB15553 )
RE-B-1800X1-4G
RE-850
RE-B-1800x1
7.2
fxp0 fxp0 fxp1 em0 11.4R4
12.1R2
M10i Routing Engines
lists the Routing Engines supported by the M10i router. The M10i router supports 32-bit Junos OS only.
Table 11: M10i Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-400-768 (EOL details:
TSB16445 )
RE-5.0
9.0
fxp0 fxp1 fxp2
Copyright © 2019, Juniper Networks, Inc.
35
M10i Multiservice Edge Router Hardware Guide
Table 11: M10i Routing Engines (continued)
Model Number
RE-850-1536 (EOL details:
TSB15553 )
Name in CLI
Output
RE-850
First Supported
32-bit Junos OS
Release
7.2
Management
Ethernet Interface
Internal Ethernet
Interface fxp0 fxp0 fxp1 fxp2 em0 RE-B-1800X1-4G RE-B-1800x1 11.4R4
12.1R2
M40e Routing Engines
lists the Routing Engines supported by the M40e router.
Table 12: M40e Routing Engines
Model Number Name in CLI Output
First Supported
Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-600-2048 (EOL details:
TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
5.3
fxp0
RE-A-1000-2048 RE-A-1000 8.1
fxp0 fxp1 fxp2 fxp1 fxp2
M120 Routing Engines
lists the Routing Engines supported by the M120 router.
Table 13: M120 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-A-1000-2048 RE-A-1000 8.0R2
– fxp0
RE-A-2000-4096
RE-A-1800X2-8G
RE-A-2000
RE-A-1800x2
8.0R2
•
•
11.4R5
12.1R3
–
10.4
fxp0 fxp0 fxp1 fxp2 em0 bcm0 fxp1 fxp2
36 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 13: M120 Routing Engines (continued)
Model Number
RE-A-1800X2-16G
Name in CLI
Output
RE-A-1800x2
RE-A-1800X4-16G RE-A-1800x4
First Supported
32-bit Junos OS
Release
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
First
Supported
64-bit Junos
OS Release
10.4
10.4
Management
Ethernet
Interface
Internal Ethernet
Interface fxp0 fxp0 fxp1 fxp2 em0 em1
M320 Routing Engines
lists the Routing Engines supported by the M320 router.
Table 14: M320 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-1600-2048 (EOL details: TSB14374 )
RE-4.0
6.2
– fxp0
RE-A-2000-4096
RE-A-1800X2-8G
RE-A-2000
RE-A-1800x2
8.1
•
•
11.4R5
12.1R3
–
10.4
fxp0 fxp0 fxp1 fxp2 em0 bcm0 em0 bcm0
RE-A-1800X2-16G RE-A-1800x2 •
•
11.4R5
12.1R3
10.4
fxp0
RE-A-1800X4-8G RE-A-1800X4 •
•
•
11.4R5
12.1R3
12.2
10.4
fxp0 em0 bcm0 em0 em1
MX5, MX10, MX40, and MX80 Routing Engine
lists the Routing Engines supported by the MX5, MX10, MX40, and
MX80 routers.
Copyright © 2019, Juniper Networks, Inc.
37
M10i Multiservice Edge Router Hardware Guide
Table 15: MX5, MX10, MX40, and MX80 Routing Engine
Model
Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface Internal Ethernet Interface
Built-in Routing
Engine
Routing Engine
RE-MX80
12.3
fxp0 em0 em1
NOTE: em1 is used to communicate with the
MS-MIC when it is inserted.
MX104 Routing Engines
lists the Routing Engines supported by MX104 routers.
Table 16: MX104 Routing Engines
Model
Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-S-MX104 Routing Engine 13.2
– fxp0 fxp1 fxp2
MX240 Routing Engines
lists the Routing Engines supported by MX240 routers.
Table 17: MX240 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
9.0
– fxp0 fxp1 fxp2
RE-S-1300-2048
(EOL details:
TSB16556
RE-S-1300
RE-S-2000-4096
(EOL details:
TSB16735
RE-S-2000
RE-S-1800X2-8G
(EOL details:
TSB16556
RE-S-1800x2
RE-S-1800x2-16G
(EOL details:
TSB16556
RE-S-1800x2
9.0
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
–
10.4
10.4
fxp0 fxp0 fxp0 fxp1 fxp2 em0 em1 em0 em1
38 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 17: MX240 Supported Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-S-1800X4-8G RE-S-1800X4 •
•
11.4R5
12.1R3
10.4
fxp0
RE-S-1800X4-16G RE-S-1800x4 •
•
11.4R5
12.1R3
10.4
fxp0
•
•
12.3R4
13.2R1
–
Internal Ethernet
Interface em0 em1 em0 em1 em0, em1 ixlv0, igb0
RE-S-1800X4-32G-S RE-S-1800X4
RE-S-X6-64G RE-S-2X00x6
•
•
12.3R4
13.2R1
15.1F4
16.1R1
17.2R1
fxp0 fxp0
RE-S-X6-64G-LT RE-S-2X00x6 -LT – fxp0 ixlv0, igb0 em0
RE-S-X6-128G RE-S-2X00x6-128 – 18.1R1
fxp0 ixlv0, igb0 em0
MX480 Routing Engines
lists the Routing Engines supported by MX480 routers.
Table 18: MX480 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
8.4
– fxp0 fxp1 fxp2
RE-S-1300-2048
(EOL details:
TSB16556
RE-S-1300
RE-S-2000-4096
(EOL details:
TSB16735
RE-S-2000
RE-S-1800X2-8G
(EOL details:
TSB16556
RE-S-1800x2
RE-S-1800X2-16G
(EOL details:
TSB16556
RE-S-1800x2
8.4
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
–
10.4
10.4
fxp0 fxp0 fxp0 fxp1 fxp2 em0 em1 em0 em1
Copyright © 2019, Juniper Networks, Inc.
39
M10i Multiservice Edge Router Hardware Guide
Table 18: MX480 Supported Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-S-1800X4-8G RE-S-1800X4 •
•
11.4R5
12.1R3
10.4
fxp0
RE-S-1800X4-16G RE-S-1800x4 •
•
11.4R5
12.1R3
10.4
fxp0
RE-S-1800X4-32G-S RE-S-1800X4
RE-S-X6-64G RE-S-2X00x6
•
•
12.3R4
13.2R1
–
•
•
12.3R4
13.2R1
15.1F4
16.1R1
17.2R1
fxp0 fxp0
RE-S-X6-64G-LT RE-S-2X00x6 -LT –
RE-S-X6-128G RE-S-2X00x6-128 – 18.1R1
fxp0 fxp0 ixlv0, igb0 em0 ixlv0, igb0 em0
MX960 Routing Engines
lists the Routing Engines supported by MX960 routers.
Table 19: MX960 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos
OS Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-S-1300-2048 (EOL details: TSB16556
RE-S-1300 8.2
– fxp0
RE-S-2000-4096 (EOL details: TSB16735
RE-S-1800X2-8G (EOL details: TSB16556
RE-S-2000
RE-S-1800x2
8.2
•
•
11.4R5
12.1R3
–
10.4
fxp0 fxp0 fxp1 fxp2 fxp1 fxp2 em0 em1
RE-S-1800X2-16G (EOL details: TSB16556
RE-S-1800x2 •
•
11.4R5
12.1R3
10.4
fxp0 em0 em1
Internal Ethernet
Interface em0 em1 em0 em1 em0 em1 ixlv0, igb0
40 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 19: MX960 Supported Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported
32-bit Junos
OS Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-S-1800X4-8G RE-S-1800x4 •
•
11.4R5
12.1R3
10.4
fxp0
RE-S-1800X4-16G RE-S-1800x4 •
•
11.4R5
12.1R3
10.4
fxp0 em0 em1 em0 em1
RE-S-1800X4-32G-S
RE-S-X6-64G
RE-S-1800x4
RE-S-2X00x6
•
•
12.3R4
13.2R1
–
•
•
12.3R4
13.2R1
fxp0 fxp0 em0 em1 ixlv0, igb0
RE-S-2X00x6 –
15.1F4
16.1R1
17.1R2
fxp0 ixlv0, igb0 RE-S-X6-64G (For
MX960-VC)
RE-S-X6-64G-LT RE-S-2X00x6 -LT – 17.2R1
fxp0
RE-S-X6-128G RE-S-2X00x6-128 – 18.1R1
fxp0 ixlv0, igb0 em0 ixlv0, igb0 em0
MX2008 Routing Engines
lists the Routing Engines supported by MX2008 routers.
Table 20: MX2008 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
REMX2008-X8-64G RE-MX2008-X8-64G 15.1F7
fxp0
REMX2008-X8-64G-LT
REMX2008-X8-128G
REMX2008-X8-64G-LT 17.2R1
RE-MX2008-X8-128G 18.2R1
fxp0 fxp0 ixlv0 ixlv1 ixlv0 ixlv1 ixlv0 ixlv1
Copyright © 2019, Juniper Networks, Inc.
41
M10i Multiservice Edge Router Hardware Guide
MX2010 Routing Engines
lists the Routing Engines supported by MX2010 routers.
Table 21: MX2010 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-MX2000-1800X4 RE-S-1800x4 12.3R2
fxp0
REMX2K-1800-32G-S
REMX2K-X8-64G
REMX2K-X8-64G-LT
REMX2K-X8-128G
RE-S-1800x4
RE-S-2X00x8
RE-S-2X00x8
•
•
12.3R4
13.2R1
•
•
•
15.1F5-S1
16.1R2
16.2R1
17.2R1
RE-MX200X8-128G 18.1R1
fxp0 fxp0 fxp0 fxp0 ixlv0 ixlv1 em0 ixlv0 ixlv1 em0 ixlv0 ixlv1 em0 em1 em0 em1
MX2020 Supported Routing Engines
lists the Routing Engines supported by MX2020 routers.
Table 22: MX2020 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-MX2000-1800X4 RE-S-1800x4 12.3R2
fxp0
REMX2K-1800-32G-S RE-S-1800x4 •
•
12.3R4
13.2R1
fxp0 em0 em1 em0 em1
42 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 22: MX2020 Supported Routing Engines (continued)
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
REMX2K-X8-64G RE-S-2X00x8 •
•
•
15.1F5-S1
16.1R2
16.2R1
fxp0
REMX2K-X8-64G-LT
REMX2K-X8-128G
RE-S-2X00x8 17.2R1
RE-MX200X8-128G 18.1R1
fxp0 fxp0 ixlv0 ixlv1 em0 ixlv0 ixlv1 em0
Internal
Ethernet
Interface ixlv0 ixlv1 em0
MX10003 Routing Engines
lists the Routing Engines supported by MX10003 routers.
Table 23: MX10003 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
JNP10003-RE1 RE-S-2X00x6 17.3R1
fxp0
JNP10003-RE1-LT RE-S-1600x8 18.1R1
fxp0 em3 em4 em3 em4
MX10008 Routing Engines
lists the Routing Engines supported on the MX10008 router.
Table 24: MX10008 Routing Engines
Model Number Name in CLI Output
First Supported
Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
JNP10K-RE1 RE X10 18.2R1
em0 bme0 bme1
Copyright © 2019, Juniper Networks, Inc.
43
M10i Multiservice Edge Router Hardware Guide
Table 24: MX10008 Routing Engines (continued)
Model Number Name in CLI Output
First Supported
Junos OS Release
JNP10K-RE1-LT RE X10 LT 18.3R1
JNP10K-RE1-128 RE X10 128G 18.3R1
Management
Ethernet Interface em0
Internal Ethernet
Interface em0 bme0 bme1 bme0 bme1
PTX1000 Routing Engines
lists the Routing Engine supported on the PTX1000.
NOTE: The PTX1000 supports 64-bit Junos OS only.
Table 25: PTX1000 Routing Engines
Model Number
Name in CLI
Output
Built-in Routing
Engine
RE-PTX1000
First Supported Junos OS
Release
Management
Ethernet Interface
•
•
16.1X65-D30
17.2R1
em0
Internal Ethernet
Interface bme0 em1
PTX3000 Routing Engines
lists the Routing Engines supported on the PTX3000.
Table 26: PTX3000 Routing Engines
Model Number
Name in CLI
Output
RE-DUO-C2600-16G RE-DUO-2600
RCB-PTX-X6-32G
NOTE: The PTX3000 supports 64-bit Junos OS only.
RE-PTX-2X00x6
First Supported Junos OS
Release
13.2R2
Management
Ethernet Interface
Internal Ethernet
Interface em0 ixgbe0 ixgbe1
16.1R4
17.1R1
This Routing Engine does not support Junos OS Release 16.2.
em0 ixlv0 ixlv1
44 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
PTX5000 Routing Engines
lists the Routing Engines supported on the PTX5000.
NOTE:
• PTX5000 supports 64-bit Junos OS only.
• The PTX5000 router supports two midplanes. The midplane identified as
Midplane-8S in the CLI output is supported in Junos OS releases, 12.1X48,
12.3, and 13.2. The enhanced midplane, identified as Midplane-8SeP is supported from Junos OS release 14.1 onwards.
The RE-DUO-2600 routing engine with Junos OS 13.2 or earlier is not supported on the PTX5000BASE2 midplane.
Table 27: PTX5000 Routing Engines
Model Number Name in CLI Output
RE-DUO-C2600-16G RE-DUO-2600
First Supported Junos OS
Release
RE-PTX-X8-64G RE-PTX-2X00x8
Management
Ethernet
Interface
12.1X48
12.3
13.2
NOTE: The PTX5000 does not support Junos OS Releases 12.1,
12.2, or 13.1.
em0
15.1F4
16.1R1
em0
Internal Ethernet
Interface ixgbe0 ixgbe1
RE-PTX-X8-128G RE-PTX-2X00x8-128G 18.1R1
em0 ixlv0 ixlv1 em1 ixlv0 ixlv1 em1
PTX10008 and PTX10016 Routing Engines
lists the Routing Engines supported on the PTX10008 and PTX10016 routers.
Copyright © 2019, Juniper Networks, Inc.
45
M10i Multiservice Edge Router Hardware Guide
Table 28: PTX10008 and PTX10016 Routing Engines
Model Number Name in CLI Output
First Supported
Junos OS Release
JNP10K-RE0 RE-PTX-2X00x4 17.2R1
JNP10K-RE1
JNP10K-RE1-LT
JNP10K-RE1-128
RE X10
RE X10 LT
RE X10 128G
18.2R1
18.3R1
18.3R1
Management
Ethernet Interface em0, em1 em0 em0 em0
Internal Ethernet
Interface bme0 bme1 bme0 bme1 bme0 bme1 bme0 bme1
T320 Routing Engines
lists the Routing Engines supported by the T320 router.
Table 29: T320 Routing Engines
Model Number Name in CLI Output
First Supported
32-bit Junos OS
Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-600-2048 (EOL details:
TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
5.3
fxp0 fxp1 fxp2
RE-1600-2048 (EOL details:
TSB14374
RE-4.0
6.2
fxp0
RE-A-2000-4096 RE-A-2000 8.1
fxp0 fxp1 fxp2 fxp1 fxp2
The T320 router supports the CB-T control board.
T640 Routing Engines
lists the Routing Engines supported by the T640 router.
46 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 30: T640 Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported 64-bit
Junos OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or
RE-3.0
(RE-600)
RE-1600-2048 (EOL details: TSB14374
RE-4.0
5.3
6.2
–
– fxp0 fxp0 fxp1 fxp2
RE-A-2000-4096 RE-A-2000 8.1
– fxp0 fxp1 fxp2 em0 bcm0
RE-DUO-C1800-8G RE-DUO-1800 32-bit Junos OS on a standalone T640 router:
11.2
32-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
64-bit Junos OS on a standalone T640 router:
11.3
em0
64-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
RE-DUO-C1800-16G RE-DUO-1800 32-bit Junos OS on a standalone T640 router:
11.4R2
64-bit Junos OS on a standalone T640 router:
11.4R2
em0
32-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
64-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
bcm0 em1 bcm0 em1
The T640 standalone router supports CB-T control board and CB-LCC in a T640 routing matrix.
T1600 Routing Engines
lists the Routing Engines supported by the T1600 router.
NOTE: (Two RE-DUO-C1800-8G or two RE-DUO-C1800-16G are required to connect to a Routing Matrix)
Table 31: T1600 Routing Engines
Model Number
Name in CLI
Output
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or
RE-3.0
(RE-600)
First Supported 32-bit
Junos OS Release
8.5
First Supported
64-bit Junos OS
Release
–
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 fxp1 fxp2
Copyright © 2019, Juniper Networks, Inc.
47
M10i Multiservice Edge Router Hardware Guide
Table 31: T1600 Routing Engines (continued)
Model Number
RE-1600-2048 (EOL details: TSB14374
RE-A-2000-4096
Name in CLI
Output
RE-4.0
(RE-1600)
RE-A-2000
First Supported 32-bit
Junos OS Release
8.5
8.5
First Supported
64-bit Junos OS
Release
–
–
RE-DUO-C1800-8G RE-TXP-LCC or
RE-DUO-1800
32-bit Junos OS on a T1600 router in a routing matrix: 9.6
NOTE: Junos OS Releases
9.6 through 10.4 support
RE-DUO-C1800-8G only during upgrade to a line-card chassis (LCC) in a routing matrix.
64-bit Junos OS on a
T1600 router in a routing matrix: 9.6
64-bit Junos OS on a standalone T1600 router: 11.1
32-bit Junos OS on a standalone T1600 router: 11.1
em0
RE-DUO-C1800-16G RE-DUO-1800 32-bit Junos OS on a standalone T1600 router:
11.4R2
32-bit Junos OS on a T1600 router in a routing matrix:
11.4R2
64-bit Junos OS on a standalone T1600 router: 11.4R2
64-bit Junos OS on a
T1600 router in a routing matrix: 11.4R2
em0
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 fxp0 fxp1 fxp2 em0 bcm0 bcm0 em1 bcm0 em1
T4000 Routing Engines
lists the Routing Engines supported by the T4000 router.
NOTE: The T4000 router supports 64-bit Junos OS only.
Table 32: T4000 Routing Engines
Model Number
Name in CLI
Output
RE-DUO-C1800-8G RE-DUO-1800
RE-DUO-C1800-16G RE-DUO-1800
First Supported 64-bit Junos OS
Release
Management
Ethernet
Interface
Standalone T4000 router: 12.1
T4000 router in a routing matrix: 13.1
em0
Standalone T4000 router: 12.1R2
T4000 router in a routing matrix: 13.1
em0
Internal Ethernet
Interface bcm0 em1 bcm0 em1
48 Copyright © 2019, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
The T4000 router supports the CB-LCC control board.
TX Matrix Routing Engines
lists the Routing Engines supported by the TX Matrix router.
Table 33: TX Matrix Routing Engines
Model Number
Name in CLI
Output
First
Supported
32-bit Junos
OS Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
7.0
– fxp0
RE-1600-2048 (EOL details: TSB14374
RE-4.0 (RE-1600) 7.0
– fxp0 fxp1 fxp2 fxp1 fxp2
RE-A-2000-4096
RE-DUO-C1800-8G
RE-DUO-C1800-16G
RE-A-2000
RE-DUO-1800
RE-DUO-1800
8.5
11.4R9
11.4R9
–
11.4R9
11.4R9
fxp0 em0 em0 em0 bcm0 bcm0 em1 bcm0 em1
The TXP router supports two control boards, CB-TX and CB-LCC. The CB-LCC is required for both RE-DUO-C1800-8G and RE-DUO-C1800-16G Routing Engines.
TX Matrix Plus Routing Engines
lists the Routing Engines supported by the TX Matrix Plus router.
Table 34: TX Matrix Plus Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-DUO-C2600-16G RE-TXP-SFC or
RE-DUO-2600
32-bit Junos OS: 9.6
64-bit Junos OS: 11.4
em0 ixgbe0 ixgbe1
The TX Matrix Plus router supports the CB-TXP control board.
Copyright © 2019, Juniper Networks, Inc.
49
M10i Multiservice Edge Router Hardware Guide
TX Matrix Plus (with 3D SIBs) Routing Engines
lists the Routing Engines supported by the TX Matrix Plus router with 3D SIBs.
Table 35: Routing Engines on TX Matrix Plus with 3D SIBs
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-DUO-C2600-16G RE-TXP-SFC or
RE-DUO-2600
64-bit Junos OS: 11.4
em0 ixgbe0 ixgbe1
Related
Documentation
•
Routing Engine Specifications on page 29
• Understanding Internal Ethernet Interfaces
• Understanding Management Ethernet Interfaces
50 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 6
Line Card Components and Descriptions
•
M10i Flexible PIC Concentrators (FPCs) Description on page 51
•
M10i PICs Description on page 51
•
•
M10i PICs Supported on page 53
•
M10i End-of-Life PICs Supported on page 56
•
M10i PIC/CFEB Compatibility on page 58
M10i Flexible PIC Concentrators (FPCs) Description
Flexible PIC Concentrators (FPCs) house the PICs that connect the router to network media (for information about PICs, see
“M10i PICs Description” on page 51
). On the M10i router, each FPC is built in (it cannot be removed from the chassis as on other M Series platforms) and corresponds to a horizontal row of PIC slots. The two FPCs on the M10i router are numbered 0 and 1 , top to bottom. Each FPC accommodates up to four PICs.
Related
Documentation
•
Connecting M10i PIC Cables on page 121
•
M10i Midplane Description on page 12
•
M10i Chassis Description on page 11
M10i PICs Description
PICs provide the physical connection to various network media types. PICs receive incoming packets from the network and transmit outgoing packets to the network, performing framing and line-speed signaling for their media type as required. PICs also encapsulate outgoing packets received from the Compact Forwarding Engine Board
(CFEB) or Enhanced CFEB (CFEB-E) before transmitting them. The controller ASIC on each PIC performs additional control functions specific to the PIC media type.
The router supports various PICs, including ATM, Channelized, Gigabit Ethernet, IP Services, and SONET/SDH interfaces. You can install PICs of different media types on the same router as long as the router supports those PICs.
PICs are inserted into a slot in Flexible PIC Concentrators (FPCs), FPC0 and FPC1 , which are built in to the chassis. Up to eight PICs install into an M10i router, as shown in
Copyright © 2019, Juniper Networks, Inc.
51
M10i Multiservice Edge Router Hardware Guide
. Four PIC slots are located in each Flexible PIC Concentrator (FPC).
The PIC slots on the upper FPC are numbered from 0/0 (zero/zero) through 0/3 , right to left. The PIC slots in the lower FPC are numbered from 1/0 (one/zero) through 1/3 , right to left. The PIC slot numbers are located above FPC0 , and below FPC1 . The number of ports on a PIC depends on the type of PIC.
Blank PICs resemble other PICs but do not provide any physical connection or activity.
When a slot is not occupied by a PIC, you must insert a blank PIC to fill the empty slot and ensure proper cooling of the system.
The M10i router has a maximum throughput of 3.2 Gbps full duplex for each FPC. Inserting a combination of PICs with an aggregate higher than the maximum throughput is supported, but constitutes oversubscription of the FPC.
Figure 14: M10i PIC Location
52
PICs are hot-removable and hot-insertable. A removed PIC no longer receives or transmits data, and removing or inserting a PIC briefly interrupts forwarding of traffic through the remaining PICs.
Most PICs supported on the M10i router have the following components.
• One or more cable connector ports—Accept a network media connector.
• LEDs—Indicate PIC and port status. Most PICs have an LED labeled STATUS on the
PIC faceplate. Some PICs have additional LEDs, often one per port. The meaning of the LED states differs for various PICs. For more information, see the description for each PIC.
• Ejector lever—Controls the locking system that secures the PIC in the card cage.
Some PICs accept small form-factor pluggables (SFPs), which are fiber-optic transceivers that can be removed from the PIC. Various SFPs have different reach characteristics.
You can mix them in a single PIC and change the combination dynamically. SFPs are hot-removable and hot-insertable, as described in
section for each PIC.
Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Related
Documentation
•
M10i PICs Supported on page 53
•
M10i Flexible PIC Concentrators (FPCs) Description on page 51
•
Installing an M10i PIC on page 173
•
M10i PIC Serial Number ID Label on page 250
•
Replacing an M10i PIC on page 179
•
Troubleshooting the M10i PICs on page 235
•
Replacing an M10i SFP on page 187
M10i PIC LEDs
LEDs indicate PIC and port status. Most PICs have an LED labeled STATUS on the PIC faceplate. Some PICs have additional LEDs, often one per port. The meaning of the LED states differs for various PICs. For more information, see the M10i Multiservice Edge Router
Interface Module Reference .
Related
Documentation
•
M10i PICs Description on page 51
•
Displaying M10i Router Components and Serial Numbers on page 247
•
M10i Chassis Description on page 11
M10i PICs Supported
lists the PICs supported in the M10i router. The PICs are listed alphabetically by PIC family.
NOTE: The M10i router is now end-of-life. See the JTAC support bulletin
TSB16809 for additional information about the PICs and other associated
FRUs that moved to end-of-life with the router. The
topic lists PICs that moved to end-of-life before the
M10i router itself moved to end-of-life.
Table 36: PICs Supported in the M10i Router
Ports Model Number Connector
First
Junos OS
Release
Support PIC Family and Type
ATM2 IQ
Copyright © 2019, Juniper Networks, Inc.
53
M10i Multiservice Edge Router Hardware Guide
Table 36: PICs Supported in the M10i Router (continued)
PIC Family and Type
ATM2 DS3 IQ PIC (M10i Router)
Ports
4
ATM2 OC3/STM1 IQ PIC (M10i
Router)
2
ATM2 OC12/STM4 IQ PIC (M10i
Router)
1
Channelized Enhanced IQ (IQE)
Channelized DS3 and E3 Enhanced
IQ (IQE) PIC (M10i Router)
NOTE: Only the DS3 interface is channelized.
4
Channelized E1/T1 Enhanced IQ (IQE)
PIC (M10i Router)
10
Channelized OC3/STM1 Enhanced IQ
(IQE) with SFP (M10i Router)
2
Channelized OC12/STM4 Enhanced
IQ (IQE) PIC with SFP (M10i Router)
1
Circuit Emulation
Channelized OC3/STM1 Circuit
Emulation PIC with SFP (M10I Router)
4
E1/T1 Circuit Emulation PIC (M10i
Router)
12
Model Number
PE-4DS3-ATM2
PE-2OC3-ATM2-MM
PE-2OC3-ATM2-SMIR
PE-1OC12-ATM2-MM
PE-1OC12-ATM2-SMIR
PE-4CHDS3-E3-IQE-BNC • Standard DS3 BNC coaxial cable interfaces
10.2
PE-10CHE1-T1-IQE-RJ48 • 120-ohm RJ-48C connector
(female)
PE-2CHOC3-STM1-IQE-SFP • LC/PC
10.2
10.2
PE-1CHOC12STM4-IQE-SFP • LC/PC 10.2
PE-4CHOC3-CE-SFP
PE-12T1E1-CE-TELCO
Connector
First
Junos OS
Release
Support
Coaxial:
•
•
10 ft (3.05-m) posilock SMB to BNC (provided)
Four pairs of Rx and Tx coaxial cables
6.1
• SC/PC 6.0
• SC/PC 6.0
• LC/PC 9.3
• RJ-21
NOTE: Cables are rated for intra-building connections only.
9.3
DS3, E1, E3, and T1
DS3/E3 Enhanced IQ (IQE) PIC (M10i
Router)
4
E1 PIC (M10i Router) 4
PE-4DS3-E3-IQE-BNC
PE-4E1-RJ48
• Standard DS3 BNC coaxial cable interfaces
10.2
• Four RJ-48 connectors (one per port)
6.0
54 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 36: PICs Supported in the M10i Router (continued)
PIC Family and Type
E3 IQ PIC (M10i Router)
Ethernet
Fast Ethernet PICs (M10i Router) 4
Ports Model Number
4 PE-4E3-QPP
PE-4FE-TX
Connector
• Standard E3 BNC coaxial cable interfaces
Gigabit Ethernet PIC with SFP (M10i
Router)
1
Ethernet Enhanced IQ2 (IQ2E)
Gigabit Ethernet Enhanced IQ2 (IQ2E)
PIC with SFP (M10i Router)
4
Services
Multiservices 100 PIC (M10i Router) 0
Tunnel Services PIC (M10i Router) 0
Serial
EIA-530 PIC (M10i Router) 2
PE-1GE-SFP
PE-4GE-TYPE1-SFP-IQ2E • Duplex LC/PC connector (Rx and Tx)
9.4
PE-MS-100-1
PE-TUNNEL
PE-2EIA530
•
•
Two-pair, Category 5 unshielded twisted-pair connectivity through an RJ-45 connector
Pinout: MDI noncrossover
6.0
• LC/PC 6.3
• None
• None
8.1
6.0
•
•
•
Two DB-25 male connectors
(one per port, included with
PIC)
V.35 requires an EIA-530 to
V.35 cable and connects to a
V.35 DTE 34-pin Winchester type male cable (one per port)
X.21 requires an EIA-530 to
X.21 cable and connects to a
X.21 DTE DB-15 male cable
6.0
First
Junos OS
Release
Support
6.1
SONET/SDH
SONET/SDH OC3/STM1 PIC with SFP
(M10i Router)
2
SONET/SDH OC3/STM1 Enhanced
IQ (IQE) PIC with SFP (M10i Router)
4
SONET/SDH OC3/STM1 (Multi-Rate)
PIC with SFP (M10i Router)
4
PE-2OC3-SON-SFP • LC/PC
PE-4OC3-STM1-IQE-SFP • LC/PC
PE-4OC3-1OC12-SON-SFP • LC/PC
8.4
10.2
8.4
Copyright © 2019, Juniper Networks, Inc.
55
M10i Multiservice Edge Router Hardware Guide
Table 36: PICs Supported in the M10i Router (continued)
PIC Family and Type
SONET/SDH OC12/STM4
(Multi-Rate) PIC with SFP (M10i
Router)
1
Ports Model Number
PE-1OC12-SON-SFP
Connector
• LC/PC
First
Junos OS
Release
Support
8.4
Related
Documentation
•
M10i PICs Description on page 51
•
M10i End-of-Life PICs Supported on page 56
•
M10i PIC/CFEB Compatibility on page 58
M10i End-of-Life PICs Supported
lists the end-of-life PICs supported in the M10i router. The PICs are listed alphabetically by PIC family.
NOTE: The M10i router is now end-of-life. See the JTAC support bulletin
TSB16809 for additional information about the PICs and other associated
FRUs that moved to end-of-life with the router. The
“M10i PICs Supported” on page 53
topic lists PICs that had not moved to end-of-life before the M10i router itself moved to end-of-life.
Table 37: End-of-Life PICs Supported in the M10i Router
Ports Model Number
First Junos OS
Release Support PIC Family and Type
ATM
ATM DS3 EOL PIC (M10i Router)
ATM E3 EOL PIC (M10i Router)
ATM2 IQ
ATM2 E3 IQ EOL PIC (M10i Router)
Channelized
Multichannel DS3 EOL PIC (M10i Router)
Channelized IQ
Channelized DS3 IQ EOL PIC (M10i Router)
4
4
2
2
4
PE-4DS3-ATM
PE-4E3-ATM
PE-2E3-ATM2
PE-2CHDS3
PE-4CHDS3-QPP
6.1
6.1
6.1
6.1
6.0
56 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 37: End-of-Life PICs Supported in the M10i Router (continued)
PIC Family and Type
Channelized E1 IQ EOL PIC (M10i Router)
Ports
10
10
Model Number
PE-10CHE1-RJ48-QPP
PE-10CHE1-RJ48-QPP-N
Channelized OC3 IQ EOL PIC (M10i Router)
Channelized OC12 IQ EOL PIC (M10i Router)
Channelized STM1 IQ EOL PIC (M10i Router)
Channelized T1 IQ EOL PIC (M10i Router)
DS3, E1, E3, T1
DS3 EOL PIC (M10i Router)
E1 PIC (M10i Router)
E3 PIC (M10i Router)
T1 EOL PIC (M10i Router)
Ethernet
Fast Ethernet PICs (M10i Router)
Gigabit Ethernet EOL PIC (M10i Router)
Ethernet IQ
Gigabit Ethernet IQ EOL PIC with SFP (M10i Router) 1
Ethernet IQ2
Gigabit Ethernet IQ2 EOL PIC with SFP (M10i
Router)
Services
Adaptive Services EOL PIC (M10i Router)
4
2
4
2
4
8
12
1
1
1
10
1
4
0
PE-1CHOC3-SMIR-QPP
PE-1CHOC12SMIR-QPP
PE-1CHSTM1-SMIR-QPP
PE-10CHT1-RJ48-QPP
PE-2DS3
PE-4DS3
PE-4E1-COAX
PE-2E3
PE-4T1-RJ48
PE-8FE-FX
PE-12FE-TX-MDI
PE-12FE-TX-MDIX
PE-1GE-LH
PE-1GE-LX
PE-1GE-SX
PE-1GE-SFP-QPP
PE-4GE-TYPE1-SFP-IQ2
PE-AS
Copyright © 2019, Juniper Networks, Inc.
6.0
7.6R3
6.1
6.0
6.0
6.0
6.0
6.0
6.1
6.0
First Junos OS
Release Support
7.6
6.1
6.0
6.0
9.1R4
9.2R3
9.3
7.4
6.1
57
M10i Multiservice Edge Router Hardware Guide
Table 37: End-of-Life PICs Supported in the M10i Router (continued)
PIC Family and Type Ports
Adaptive Services II EOL PIC (M10i Router) 0
Adaptive Services II Layer 2 Services EOL PIC (M10i
Router)
0
Adaptive Services II FIPS EOL PIC (M10i Router)
ES EOL PIC (M10i Router)
Link Services EOL PIC (M10i Router)
0
0
0
Model Number
PE-AS2
PB-AS2-LAYER2SERVICES
PE-AS2-FIPS
PE-ES-800
PE-LS-4
PE-LS-32
PE-LS-128
PE-PM Monitoring Services EOL PIC (M10i Router)
SONET/SDH
SONET/SDH OC3c/STM1 EOL PIC (M10i Router)
0
2
4
SONET/SDH OC12c/STM4 EOL PIC (M10i Router) 1
PE-2OC3-SON-MM
PE-2OC3-SON-SMIR
PE-4OC3-SON-MM
PE-4OC3-SON-SMIR
PE-1OC12-SON-MM
PE-1OC12-SON-SMIR
PE-1OC12-STM4-IQE-SFP SONET/SDH OC12/STM4 Enhanced IQ (IQE) EOL
PIC with SFP (M10i Router)
1
SONET/SDH OC48c/STM16 EOL PIC with SFP 1 PE-1OC48-SON-SFP
6.0
6.0
6.0
10.2
6.4
7.2
6.1
6.1
First Junos OS
Release Support
6.4
8.0R2
6.1
Related
Documentation
•
M10i PICs Description on page 51
•
M10i PICs Supported on page 53
•
M10i PIC/CFEB Compatibility on page 58
M10i PIC/CFEB Compatibility
lists the PICs and CFEBs supported on the M10i router.
Table 38: PICs Supported in the M10i Router
PIC Family and Type Ports Model Number CFEB CFEB-E
ATM
58 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 38: PICs Supported in the M10i Router (continued)
PIC Family and Type Ports Model Number
ATM DS3 EOL PIC (M10i Router) 4
ATM E3 EOL PIC (M10i Router) 4
PE-4DS3-ATM
EOL (see notification PSN-2003-10-018 )
PE-4E3-ATM
EOL (see notification PSN-2003-10-018 )
ATM2 IQ
ATM2 DS3 IQ
ATM2 E3 IQ
ATM2 OC3/STM1 IQ
ATM2 OC12/STM4 IQ
4
2
2
1
PE-4DS3-ATM2
PE-2E3-ATM2
PE-2OC3-ATM2-MM
PE-2OC3-ATM2-SMIR
PE-1OC12-ATM2-MM
PE-1OC12-ATM2-SMIR
Channelized
Multichannel DS3 EOL PIC (M10i
Router)
2
Channelized IQ
Channelized DS3 IQ
Channelized E1 IQ
4
10
PE-2CHDS3
EOL (see notification PSN-2004-10-026 )
PE-4CHDS3-QPP
PE-10CHE1-RJ48-QPP-N
Channelized OC12 IQ
Channelized OC3 IQ
Channelized STM1 IQ
Channelized T1 IQ
Channelized IQE
Channelized DS3 and E3
Enhanced IQ (IQE)
4
Channelized E1/T1 Enhanced IQ
(IQE)
10
Channelized OC3/STM1
Enhanced IQ (IQE) with SFP
2
Channelized OC12/STM4
Enhanced IQ (IQE) PIC with SFP
1
1
10
1
1
PE-1CHOC12SMIR-QPP
PE-1CHOC3-SMIR-QPP
PE-1CHSTM1-SMIR-QPP
PE-10CHT1-RJ48-QPP
PE-4CHDS3-E3–IQE-BNC
PE-10CHE-T1-IQE-RJ48
PE-2CHOC3-STM1-IQE-SFP
PE-1CHOC12STM4-IQE-SFP
6.1
6.1
6.1
CFEB
6.1
6.1
6.1
6.1
7.1
6.1
7.4
6.1
9.1R4
9.2R3
9.3
–
–
–
–
CFEB-E
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
10.2
10.2
10.2
10.2
Copyright © 2019, Juniper Networks, Inc.
59
M10i Multiservice Edge Router Hardware Guide
Table 38: PICs Supported in the M10i Router (continued)
PIC Family and Type Ports Model Number
Circuit Emulation
Channelized OC3/STM1 Circuit
Emulation
4
E1/T1 Circuit Emulation 12
PE-4CHOC3-CE-SFP
PE-12T1E1-CE-TELCO
DS3, E1, E3, and T1
DS3
DS3/E3 Enhanced IQ (IQE)
E1
E3
E3 IQ
T1
E3
E3 PIC (M10i Router)
2
4
4
4
4
2
4
4
PE-2DS3
PE-4DS3
PE-4DS3-E3-IQE-BNC
PE-4E1-COAX
PE-4E1-RJ48
PE-2E3
PE-4E3-QPP
PE-4T1-RJ48
PE-4E3
EOL (see notification PSN-2003-10-018 )
Ethernet
Fast Ethernet
Gigabit Ethernet EOL PIC (M10i
Router)
1
4
8
12
PE-4FE-TX
PE-8FE-FX
PE-12FE-TX-MDI
PE-12FE-TX-MDIX
PE-1GE-LH
EOL (see notification PSN-2004-06-014 )
PE-1GE-LX
EOL (see notification PF-HW-0103-001 )
PE-1GE-SX
EOL (see notification PF-HW-0103-001 )
CFEB
9.3
9.3
–
6.1
6.1
6.1
6.0
6.1
6.1
6.1
6.1
6.1
6.1
6.1
CFEB-E
9.5
9.5
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.4
10.2
9.4
60 Copyright © 2019, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 38: PICs Supported in the M10i Router (continued)
PIC Family and Type Ports Model Number
1 PE-1GE-SFP Gigabit Ethernet with SFP
Ethernet IQ
Gigabit Ethernet IQ 1 PE-1GE-SFP-QPP
Ethernet IQ2
Gigabit Ethernet IQ2 4
Ethernet Enhanced IQ2 (IQ2E)
Gigabit Ethernet IQ2E 4
Services
Link Services 0
PE-4GE-TYPE1-SFP-IQ2
PE-4GE-TYPE1-SFP-IQ2E
PE-LS-4
PE-LS-32
PE-LS-128
PE-MS-100-1 Multiservices 100 PIC (M10i
Router)
Tunnel Services PIC (M10i
Router)
0
0
Adaptive Services EOL PIC (M10i
Router)
0
Adaptive Services II EOL PIC
(M10i Router)
0
Adaptive Services II Layer 2
Services EOL PIC (M10i Router)
0
Adaptive Services II FIPS EOL PIC
(M10i Router)
0
ES EOL PIC (M10i Router) 0
Link Services EOL PIC (M10i
Router)
Monitoring Services EOL PIC
(M10i Router)
0
0
PE-TUNNEL
PE-AS
EOL (see notification PSN-2005-06-007 )
PE-AS2
EOL (see notification PSN-2007-12-036 )
PB-AS2-LAYER2SERVICES
EOL (see notification PSN-2008-11-080 )
PE-AS2-FIPS
EOL (see notification PSN-20011-09-381 )
PE-ES-800
EOL (see notification PSN-2010-04-734 )
PE-LS-4
EOL (see notification PSN-2008-11-080 )
PE-LS-32
EOL (see notification PSN-2008-11-080 )
PE-LS-128
EOL (see notification PSN-2008-11-080 )
PE-PM
EOL (see notification PSN-2005-06-007 )
Serial
CFEB
6.3
6.1
7.6R3
9.4
6.1
8.1
6.1
6.1
6.4
8.0R2
6.0
6.0
6.1
CFEB-E
9.4
9.4
9.4
9.5R2
–
9.4
9.4
9.4
Copyright © 2019, Juniper Networks, Inc.
61
M10i Multiservice Edge Router Hardware Guide
Table 38: PICs Supported in the M10i Router (continued)
PIC Family and Type Ports Model Number
PE-2EIA530 EIA-530 2
SONET/SDH
SONET/SDH OC3/STM1 PIC with
SFP (M10i Router)
2 PE-2OC3-SON-SFP
SONET/SDH OC3/STM1
Enhanced IQ (IQE) PIC with SFP
(M10i Router)
4
SONET/SDH OC3/STM1
(Multi-Rate) PIC with SFP (M10i
Router)
4
SONET/SDH OC12/STM4
Enhanced IQ (IQE) EOL PIC with
SFP (M10i Router)
1
SONET/SDH OC12/STM4
(Multi-Rate) PIC with SFP (M10i
Router)
1
SONET/SDH OC48c/STM16 EOL
PIC with SFP
1
SONET/SDH OC3c/STM1 EOL
PIC (M10i Router)
2
PE-4OC3-STM1-IQE-SFP
PE-4OC3-1OC12-SON-SFP
PE-1OC12-STM4-IQE-SFP
PE-1OC12-SON-SFP
PE-1OC48-SON-SFP
• SONET/SDH OC3c/STM1 PIC 2
• SONET/SDH OC3c/STM1 PIC 4
PE-2OC3-SON
EOL (see notification PSN-2007-12-037 )
PE-2OC3-SON-MM
PE-2OC3-SON-SMIR
PE-4OC3-SON-MM
PE-4OC3-SON-SMIR
SONET/SDH OC12c/STM4 EOL
PIC (M10i Router)
1 PE-1OC12-SON-MM
EOL (see notification PSN-2007-12-037 )
PE-1OC12-SON-SMIR
EOL (see notification PSN-2007-12-037 )
Related
Documentation
•
M10i PICs Description on page 51
•
M10i PICs Supported on page 53
CFEB
6.1
8.4
–
8.4
–
8.4
6.4
6.0
6.0
CFEB-E
9.4
–
9.4
9.6
10.2
9.4
10.2
9.4
9.4
62 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 7
Power System Components and
Descriptions
•
M10i Power System Description on page 63
•
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
•
M10i Power Supply LEDs on page 66
M10i Power System Description
The router uses either AC or DC power. You can install up to three AC power supplies or four DC load-sharing power supplies at the bottom rear of the chassis, as shown in
6 on page 12 . The power supplies connect to the midplane, which distributes power to
router components according to their individual voltage requirements. When the power supplies are installed and operational, they automatically share the electrical load.
An enable control pin on the output connector of each power supply ensures that the supply is fully seated into the router midplane before the supply can be turned on. The enable pin prevents a user-accessible energy hazard, so there is no interlocking mechanism. The enable pin disables the voltage at the output connector if the power supply is not turned off before removal.
Redundant power supplies are hot-removable and hot-insertable, as described in
Field-Replaceable Units (FRUs)” on page 139
.
Copyright © 2019, Juniper Networks, Inc.
63
M10i Multiservice Edge Router Hardware Guide
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on. After powering on a power supply, wait at least 60 seconds before turning it off.
If the router is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence.
If the Routing Engine finishes booting and you need to power off the router again, see
“Powering Off the M10i Router” on page 129
.
After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the output status LED on the power supply, the command display output, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
Figure 15: M10i Router Power Supplies
Related
Documentation
•
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
•
Troubleshooting the M10i Power System on page 237
•
Replacing an M10i AC Power Supply on page 195
•
Replacing an M10i DC Power Supply on page 201
.
M10i AC Power Supply Description
An AC-powered router has up to three load-sharing AC power supplies, located at the bottom rear of the chassis, as shown in
. For information about power supply redundancy and replaceability, see
“M10i Power System Description” on page 63 .
The router must have at least two AC power supplies, and any two AC power supplies can provide full power to the router. Three power supplies are required for redundancy.
64 Copyright © 2019, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
shows the power supply and
lists electrical specifications. For information about the LED, see
“M10i Power Supply LEDs” on page 66 .
Figure 16: AC Power Supply
Related
Documentation
•
Replacing an M10i AC Power Supply on page 195
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
M10i DC Power Supply Description
A DC-powered router has up to four load-sharing DC power supplies, located at the bottom rear of the chassis, as shown in
. For information about power supply redundancy and replaceability, see
“M10i Power System Description” on page 63 .
The router must have at least two DC power supplies, and any two DC power supplies can provide full power to the router. DC system redundancy requires two power sources from feed A and two power sources from feed B. If one feed fails or is shut down for service, the other feed powers two DC power supplies and can provide full power to the router's components indefinitely.
shows the power supply and
lists electrical specifications. For information about the LED, see
“M10i Power Supply LEDs” on page 66 .
Figure 17: DC Power Supply
Related
Documentation
•
Replacing an M10i DC Power Supply on page 201
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
Copyright © 2019, Juniper Networks, Inc.
65
M10i Multiservice Edge Router Hardware Guide
M10i Power Supply LEDs
describes the LED on both AC and DC power supplies.
Table 39: States for Power Supply LED
Label Color State Description
OUTPUT OK Green On steadily Power supply is functioning normally, input is occurring, outputs are within range, and the temperature is within range.
Blinking Power supply is not functioning, is starting up, is not properly inserted, or airflow is not sufficient.
Related
Documentation
•
Installing an M10i AC Power Supply on page 191
•
M10i Power System Description on page 63
•
Replacing an M10i AC Power Supply on page 195
•
Troubleshooting the M10i Power System When LEDs on All Power Supplies Are Off on page 237
66 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 8
Switch Fabric Components and
Descriptions
•
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description on page 67
•
M10i CFEB and CFEB-E LEDs on page 71
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description
The Compact Forwarding Engine Board (CFEB) or Enhanced Compact Forwarding Engine
Board (CFEB-E) performs route lookup, filtering, and switching on incoming data packets, then directs outbound packets to the appropriate FPC for transmission to the network.
It can process 15 million packets per second (Mpps).
One or two CFEBs or CFEB-Es can be installed into the midplane from the rear of the chassis, as shown in
.
CAUTION: The M10i Internet router does not support a mixture of CFEB and
CFEB-E hardware. If you install two devices, they must both be CFEBs or they must both be CFEB-Es.
Only one CFEB or CFEB-E is active at a time; the optional second CFEB or CFEB-E is in standby mode. By default, the CFEB or CFEB-E in slot CFEB 0 is active. To modify the default, include the appropriate cfeb statement at the [edit chassis redundancy] hierarchy level of the configuration, as described in the section about CFEB or CFEB-E redundancy in the Junos OS Administration Library .
NOTE: For specific information about CFEB or CFEB-E components (for example, the amount of SDRAM), issue the show chassis cfeb command.
CFEBs or CFEB-Es are hot-pluggable when you replace a CFEB with a CFEB or a CFEB-E with a CFEB-E, as described in
“M10i Field-Replaceable Units (FRUs)” on page 139 . To
upgrade from a CFEB to a CFEB-E or to downgrade from a CFEB-E to a CFEB requires a
Copyright © 2019, Juniper Networks, Inc.
67
M10i Multiservice Edge Router Hardware Guide system reboot as described in
“Upgrading or Downgrading an M10i CFEB or CFEB-E” on page 215
.
Removing the standby CFEB or CFEB-E has no effect on router function. If the active
CFEB or CFEB-E fails or is removed from the chassis, the effect depends on how many
CFEBs or CFEB-Es are installed:
• If there is one CFEB or CFEB-E, forwarding halts until the CFEB or CFEB-E is replaced and functioning again. For a minimum configuration, it takes approximately 2 minutes for the replaced CFEB or CFEB-E to boot and become active; reading in router configuration information can take additional time, depending on the complexity of the configuration.
• If there are two CFEBs or CFEB-Es, forwarding halts while the standby CFEB or CFEB-E boots and becomes active, which takes approximately 1 minute; synchronizing router configuration information can take additional time, depending on the complexity of the configuration.
For CFEB or CFEB-E replacement instructions, see
“Replacing, Upgrading, or Downgrading an M10i CFEB or CFEB-E” on page 212 .
The CFEB or CFEB-E communicates with the Routing Engine using a dedicated 100-Mbps
Fast Ethernet link that transfers routing table data from the Routing Engine to the forwarding table in the integrated ASIC. The link is also used to transfer from the CFEB or CFEB-E to the Routing Engine routing link-state updates and other packets destined for the router that have been received through the router interfaces.
The CFEB or CFEB-E provides the following functions:
• Route lookups—Performs route lookups using the forwarding table stored in the synchronous SRAM (SSRAM) on CFEBs or stored in the RLDRAM on CFEB-Es.
• Management of shared memory —Uniformly allocates incoming data packets throughout the router's shared memory.
• Transfer of outgoing data packets—Passes data packets to the destination FIC or PIC when the data is ready to be transmitted.
• Transfer of exception and control packets—Passes exception packets to the microprocessor on the CFEB or CFEB-E, which processes almost all of them. The remainder are sent to the Routing Engine for further processing. Any errors originating in the Packet Forwarding Engine and detected by the CFEB or CFEB-E are sent to the
Routing Engine using system log messages.
68 Copyright © 2019, Juniper Networks, Inc.
CFEB
Figure 18: CFEB
Chapter 8: Switch Fabric Components and Descriptions
The CFEB has the following major components:
• Processing components:
• 266-MHz CPU and supporting circuitry
• Integrated ASIC
• 33-MHz PCI bus
• Storage components:
• 128-MB SDRAM for packet memory
• 128-MB SDRAM for the microkernel
• 8-MB SSRAM for route lookup
• 4-MB SSRAM for control memory
• System interfaces:
• 100-Mbps Ethernet link for internal interface to the Routing Engine
• 19.44-MHz reference clock that generates clock signal for SONET/SDH PICs
• I2C controller to read the I2C/EEPROMs in the PICs and temperature sensors
• I2C/EEPROM containing the serial number and revision level
• Two 512-KB boot flash EPROMs (programmable on the board)
• One PowerPC 8245 integrated processor
• Three LEDs—A green LED labeled OK , a red LED labeled FAIL , and a blue LED labeled
MASTER indicate CFEB status. See
“M10i CFEB and CFEB-E LEDs” on page 71 .
• Online/Offline button—Prepares the CFEB for removal from the router when pressed.
• Ejector levers—Control the locking system that secures the CFEB in the chassis.
Copyright © 2019, Juniper Networks, Inc.
69
M10i Multiservice Edge Router Hardware Guide
CFEB-E
The CFEB-E provides the following enhanced features:
• Increased number of logical interfaces.
• Increased route, nexthop, and interface lookup memory.
• Increased FPC throughput.
• Enhanced class of service features, including:
• More queues and priority levels
• Increased drop precedence per queue
• Excess bandwidth allocation in proportion to weights
• Hierarchical policing
• Increased number of WRED profiles
• Independent EXP and DSCP rewrite
• Independent Layer 2 and Layer 3 classification on same port
Figure 19: CFEB-E
70
The CFEB-E has the following major components:
• Processing components:
• 1-GHz CPU and supporting circuitry
• Integrated ASIC
• 33-MHz PCI bus
• Storage components:
• Three 256-MB SDRAMs for packet memory
• 1-GB SDRAM for the microkernel
Copyright © 2019, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
• Two 64-MB RLDRAMs for route lookup
• Two 64-MB RLDRAMs for control memory
• System interfaces:
• 100-Mbps link for internal interface to the Routing Engine
• 19.44-MHz reference clock—Generates clock signal for SONET/SDH PICs
• I2C controller to read the I2C/EEPROMs in the PICs and temperature sensors
• I2C/EEPROM containing the serial number and revision level
• Two 512-KB boot flash EPROMs (programmable on the board)
• One MPC8545 integrated processor with 1-GB DDR2 SDRAM
• Three LEDs—A green LED labeled OK , a red LED labeled FAIL , and a blue LED labeled
MASTER indicate CFEB-E status.
• Offline button—Prepares the CFEB-E for removal from the router when pressed.
• Ejector levers—Control the locking system that secures the CFEB-E in the chassis.
Related
Documentation
•
M10i Packet Forwarding Engine Architecture Overview on page 5
•
M10i Routing Engine Description on page 21
• Configuring CFEB Redundancy on the M10i Router
•
Installing an M10i CFEB or CFEB-E on page 211
•
M10i Router Physical Specifications on page 76
M10i CFEB and CFEB-E LEDs
Three LEDs—A green LED labeled OK , a red LED labeled FAIL , and a blue LED labeled
MASTER indicate CFEB-E status.
Table 40: States for CFEB or CFEB-E LEDs
Label Color State Description
OK Green On steadily CFEB/CFEB-E is running normally.
FAIL Red
Blinking
Off
CFEB/CFEB-E is starting up.
CFEB/CFEB-E is offline or is functioning as the backup CFEB/CFEB-E.
On steadily CFEB/CFEB-E is not operational or is in reset mode.
Off CFEB/CFEB-E is functioning properly
Copyright © 2019, Juniper Networks, Inc.
71
M10i Multiservice Edge Router Hardware Guide
Table 40: States for CFEB or CFEB-E LEDs (continued)
Label Color State Description
MASTER Blue On steadily CFEB/CFEB-E is functioning as master.
Off CFEB/CFEB-E is not functioning as master.
Related
Documentation
•
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description on page 67
72 Copyright © 2019, Juniper Networks, Inc.
PART 2
Site Planning, Preparation, and
Specifications
•
Preparation Overview on page 75
•
AC Power Requirements and Specifications on page 85
•
DC Power Requirements and Specifications on page 89
•
Network Cable and Transceiver Planning on page 93
•
Management Cable and Transceiver Specifications and Pinouts on page 99
Copyright © 2019, Juniper Networks, Inc.
73
M10i Multiservice Edge Router Hardware Guide
74 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 9
Preparation Overview
•
M10i Router Site Preparation Checklist on page 75
•
M10i Router Physical Specifications on page 76
•
M10i Rack Size and Strength on page 77
•
Spacing of Mounting Holes on page 78
•
Connection to Building Structure on page 79
•
Clearance Requirements for Airflow and Hardware Maintenance on page 79
•
M10i Router Environmental Specifications on page 80
•
M10i Chassis Grounding Cable and Lug Specifications on page 81
•
M10i Router Power Requirements on page 82
M10i Router Site Preparation Checklist
The checklist in
summarizes the tasks you need to perform when preparing a site for router installation.
Table 41: Site Preparation Checklist
Item or Task For More Information Performed By Date
Environment
Verify that environmental factors such as temperature and humidity do not exceed router tolerances.
Power
Measure distance between external power sources and router installation site.
Locate sites for connection of system grounding.
Calculate the power consumption and requirements.
“M10i Chassis Grounding Cable and
Lug Specifications” on page 81
“M10i Router Power Requirements” on page 82
Copyright © 2019, Juniper Networks, Inc.
75
M10i Multiservice Edge Router Hardware Guide
Table 41: Site Preparation Checklist (continued)
Item or Task For More Information
Hardware Configuration
Choose the configuration.
Rack
Verify that your rack meets the minimum requirements for the installation of the router.
“Installation Safety Warnings for
Juniper Networks Devices” on page 269
Plan rack location, including required space clearances.
“Clearance Requirements for Airflow and Hardware Maintenance” on page 79
“M10i Rack Size and Strength” on page 77
If a rack is used, secure rack to floor and building structure.
“Connection to Building Structure” on page 79
Cables
Acquire cables and connectors:
•
•
Determine the number of cables needed based on your planned configuration.
Review the maximum distance allowed for each cable. Choose the length of cable based on the distance between the hardware components being connected.
Fiber-Optic Cable for M Series, MX
Series, and T Series Routers” on page 95
Fiber-Optic Cable for M Series, MX
Series, and T Series Routers” on page 95
Plan the cable routing and management.
“Maintaining the M10i PICs and PIC
Performed By Date
Related
Documentation
•
M10i Router Description on page 3
•
M10i Router Physical Specifications on page 76
•
M10i Router Power Requirements on page 82
M10i Router Physical Specifications
summarizes physical specifications for the router chassis.
76 Copyright © 2019, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Table 42: M10i Chassis Physical Specifications
Description Weight
Chassis dimensions 79 lb (35.8 kg) maximum configuration
57 lb (25.9 kg) minimum configuration
Width Depth
•
•
17.5 in. (44.5 cm) for sides of chassis
19 in. (48.3 cm) with mounting brackets
18 in. (45.7 cm)
Height
8.7 in. (22.1 cm)
Related
Documentation
•
M10i Router Environmental Specifications on page 80
•
M10i Router Power Requirements on page 82
•
M10i Router Description on page 3
M10i Rack Size and Strength
The router is designed for installation in a 19-in. rack as defined in Cabinets, Racks, Panels, and Associated Equipment (document number EIA-310-D) published by the Electronics
Components Industry Association ( http://www.ecianow.org/ ).
With the use of adapters, the router is designed to fit into a 600-mm-wide and
600-mm-deep rack, as defined in the four-part Equipment Engineering (EE); European telecommunications standard for equipment practice (document numbers ETS 300 119-1 through 119-4) published by the European Telecommunications Standards Institute
( http://www.etsi.org
). Use approved wing devices to narrow the opening between the rails.
The rack rails must be spaced widely enough to accommodate the router chassis's external dimensions: 8.7 in. (22.1 cm) high, 18 in. (45.7 cm) deep, and 17.5 in. (44.5 cm) wide. The outer edges of the mounting brackets extend the width to 19 in. (48.3 cm). The spacing of rails and adjacent racks must also allow for the clearances around the router and rack that are specified in
“Clearance Requirements for Airflow and Hardware
The chassis height of 8.7 in. (22.1 cm) is approximately 5 U. A U is the standard rack unit defined in Cabinets, Racks, Panels, and Associated Equipment (document number
EIA-310-D) published by the Electronics Components Industry Association. You can stack eight router in a rack that has at least 40 U (70 in. or 1.78 m) of usable vertical space.
The rack must be strong enough to support the weight of the fully configured router, up to approximately 79 lb (35.8 kg). If you stack eight fully configured routers in one rack, it must be capable of supporting about 632 lb (286.7 kg).
Copyright © 2019, Juniper Networks, Inc.
77
M10i Multiservice Edge Router Hardware Guide
Figure 20: Typical Open-Frame Rack
Related
Documentation
•
M10i Router Site Preparation Checklist on page 75
•
Installing the M10i Router into a Rack on page 113
•
Installation Safety Warnings for Juniper Networks Devices on page 269
•
Spacing of Mounting Holes on page 78
Spacing of Mounting Holes
The holes in the mounting brackets are spaced at 1 U (1.75 in. or 4.45 cm), so the router can be mounted in any rack that provides holes spaced at that distance.
Related
Documentation
•
M10i Router Site Preparation Checklist on page 75
•
Installing the M10i Router into a Rack on page 113
•
Installation Safety Warnings for Juniper Networks Devices on page 269
•
M10i Rack Size and Strength on page 77
78 Copyright © 2019, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Connection to Building Structure
Always secure the rack to the structure of the building. If your geographical area is subject to earthquakes, bolt the rack to the floor. For maximum stability, also secure the rack to ceiling brackets. For more information, see
“Installation Safety Warnings for Juniper
.
Related
Documentation
•
M10i Router Site Preparation Checklist on page 75
•
Installing the M10i Router into a Rack on page 113
•
M10i Rack Size and Strength on page 77
Clearance Requirements for Airflow and Hardware Maintenance
When planning the installation site, you must allow sufficient clearance around the rack
(see
• For the cooling system to function properly, the airflow around the chassis must be unrestricted.
depicts the airflow in the router. Allow at least 6 in.
(15.2 cm) of clearance between side-cooled routers. Allow 2.8 in. (7 cm) between the side of the chassis and any non-heat-producing surface such as a wall.
NOTE: We recommend that you do not install the router in a cabinet. If you mount the router in a cabinet, be sure that ventilation is sufficient to prevent overheating.
• For service personnel to remove and install hardware components, there must be adequate space at the front and back of the router. At least 24 in. (61 cm) is required both in front of and behind the router. NEBS GR-63 recommends that you allow at least 30 in. (76.2 cm) in front of the rack and 24 in. (61 cm) behind the rack.
Copyright © 2019, Juniper Networks, Inc.
79
M10i Multiservice Edge Router Hardware Guide
Figure 21: Chassis Dimensions and Clearance Requirements
Related
Documentation
•
M10i Router Site Preparation Checklist on page 75
•
Installing the M10i Router into a Rack on page 113
•
Installation Safety Warnings for Juniper Networks Devices on page 269
•
M10i Rack Size and Strength on page 77
M10i Router Environmental Specifications
specifies the environmental specifications required for normal router operation. In addition, the site should be as dust-free as possible.
Table 43: M10i Router Environmental Specifications
Description Value
Altitude
Relative humidity
Temperature
No performance degradation to 10,000 ft (3048 m)
Normal operation ensured in relative humidity range of 5% to 90%, noncondensing
Normal operation ensured in temperature range of 32°F (0°C) to
104°F (40°C)
Nonoperating storage temperature in shipping crate: –40°F (–40°C) to 158°F (70°C)
80 Copyright © 2019, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Table 43: M10i Router Environmental Specifications (continued)
Description Value
Seismic Tested to meet Telcordia Technologies Zone 4 earthquake requirements
Maximum thermal output •
•
AC: 3276 BTU/hour (960 W)
DC: 1965 BTU/hour (576 W)
NOTE: Install the router only in restricted areas, such as dedicated equipment rooms and equipment closets, in accordance with Articles 110-16, 110-17, and
110-18 of the National Electrical Code, ANSI/NFPA 70.
Related
Documentation
•
M10i Router Physical Specifications on page 76
•
M10i Router Power Requirements on page 82
•
M10i Router Description on page 3
•
General Safety Guidelines for Juniper Networks Devices on page 261
•
General Safety Warnings for Juniper Networks Devices on page 262
M10i Chassis Grounding Cable and Lug Specifications
You must supply one 14-AWG (2.08 mm
2
) single-strand-count wire cable for the grounding the router.
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the grounding cable that you supply. One terminal lug, 14-AWG
(2.08 mm
2
) , two hole for grounding is provided in the accessory box.
shows the grounding points on the router above the power supplies.
Copyright © 2019, Juniper Networks, Inc.
81
M10i Multiservice Edge Router Hardware Guide
Figure 22: Grounding Cable and Grounding Points
Related
Documentation
•
M10i Chassis Description on page 11
•
Grounding the M10i Router on page 117
M10i Router Power Requirements
lists the power requirements for various hardware components when the router is operating under typical voltage conditions. For PIC power requirements, see the M10i Multiservice Edge Router Interface Module Reference .
Table 44: Component Power Requirements
Component
Power Requirement (Watts)
@ 48 V
Power Requirement (Amps) @
48 V
1.8 A (approximate) Base system including two HCMs, two power supplies, and one Routing Engine (with fans running at normal speed)
88.3
Routing Engine
CFEB/CFEB-E
33.6
67.2
0.7 A
1.4 A
82 Copyright © 2019, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Table 44: Component Power Requirements (continued)
Component
Power Requirement (Watts)
@ 48 V
Power Requirement (Amps) @
48 V
HCM 10 0.2 A
You can use the information in
and the M10i Multiservice Edge Router
Interface Module Reference to calculate power consumption for various hardware configurations, input current from a different source voltage, and thermal output, as shown in the following examples. (The examples use a generalized value for PICs of
0.625 A @ 48 V each.)
• Power consumption for minimum configuration:
Base system + 1 CFEB + 1 PIC =
1.8 A + 0.625 A = 2.425 A @ 48 V = 116.4 W DC
• Power consumption for maximum configuration:
Base system + 2 CFEBs + 8 PICs + second Routing Engine =
1.8 A + 2(1.4 A) + 8(0.625_A) + 0.7 A =
1.8 A + 2.8 A + 5_A + 0.7 A = 10.3 A @ 48 V = 494.4 W DC
• Input current from a DC source other than 48 V (based on maximally configured router; applies to DC power supply only):
(54 VDC input) x (input current X) = (48 VDC input) x (input current Y)
54 x X = 48 x 8.9 A
X = 48 x 8.9 A / 54 = 7.9 A
• Example of calculating system thermal output for an AC-powered router:
Watts DC/65% AC PEM efficiency/0.293 = BTU/hr
494.4/0.65/0.293 = 2595.96 BTU/hr
• Example of calculating System thermal output for aDC-powered router:
Watts DC/0.293 = BTU/hr
494.4/0.293 = 1687.37 BTU/hr
NOTE: We recommend that you provision at least 9.1 A @ 48 VDC and use a facility circuit breaker rated for 15 A minimum. Doing so enables you to operate the router in any configuration without upgrading the power infrastructure, and allows the router to function at full capacity using multiple power supplies.
Related
Documentation
•
M10i Router AC Power Supply Specifications on page 85
Copyright © 2019, Juniper Networks, Inc.
83
M10i Multiservice Edge Router Hardware Guide
84 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 10
AC Power Requirements and
Specifications
•
M10i Router AC Power Supply Specifications on page 85
•
M10i AC Power Cord Specifications on page 86
M10i Router AC Power Supply Specifications
lists electrical specifications for the AC Power Supply.
Table 45: Electrical Specifications for AC Power Supply
Description Specification
Maximum power output
AC input voltage
AC input line frequency
293 WDC
Nominal: 100, 120, 200, 208, 220, 240 VAC
Operating range: 90–264 VAC
47–63 Hz
AC input current rating
Output voltages
6–3 A
+3.3 V @ 40 A, +2.5 V @ 20 A, +5.0 V @ 15 A, +12 V@ 3 A
Related
Documentation
•
M10i AC Power Supply Description on page 64
•
Replacing an M10i AC Power Supply on page 195
•
Replacing an M10i AC Power Cord on page 199
•
M10i Router Power Requirements on page 82
•
M10i AC Power Cord Specifications on page 86
Copyright © 2019, Juniper Networks, Inc.
85
M10i Multiservice Edge Router Hardware Guide
M10i AC Power Cord Specifications
Detachable AC power cords, each 2.5 m (approximately 8 ft) long, are supplied with the router. The C13 appliance coupler at the female end of the cord inserts into the AC appliance inlet coupler, type C14 as described by International Electrotechnical
Commission (IEC) standard 60320. The plug at the male end of the AC power cord fits into the power source receptacle that is standard for your geographical location.
NOTE: In North America, AC power cords must not exceed 4.5 m
(approximately 14.75 ft) in length, to comply with National Electrical Code
(NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52, and Canadian Electrical
Code (CEC) Section 4-010(3). The cords supplied with the router are in compliance.
provides specifications and
depicts the plug on the AC power cord provided for each country or region.
Table 46: AC Power Cord Specifications
Country Electrical Specification Plug Type
Australia 240 VAC, 50 Hz AC
Europe (except Italy and United Kingdom) 220 or 230 VAC, 50 Hz AC
Italy
North America
230 VAC, 50 Hz AC
120 VAC, 60 Hz AC
SAA/3
CEE 7/7
CEI 23-16
NEMA 5-15P
United Kingdom 240 VAC, 50 Hz AC BS89/10
Figure 23: AC Plug Types
Australia
(SAA/3)
China
(PSB-10)
Europe
(CEE 7/7)
Italy
(CEI 23-16/VII)
86
Japan
(L6-20P)
North America
(L6-20P)
North America
NEMA
(L6-20)
UK
(BS89/13)
Copyright © 2019, Juniper Networks, Inc.
Chapter 10: AC Power Requirements and Specifications
NOTE: AC power cords must not block access to router components or drape where people could trip on them.
Related
Documentation
•
M10i AC Power Supply Description on page 64
•
Connecting Power on an AC-Powered M10i Router on page 123
•
Replacing an M10i AC Power Supply on page 195
•
Replacing an M10i AC Power Cord on page 199
•
M10i Router Power Requirements on page 82
•
M10i Router AC Power Supply Specifications on page 85
Copyright © 2019, Juniper Networks, Inc.
87
M10i Multiservice Edge Router Hardware Guide
88 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 11
DC Power Requirements and
Specifications
•
M10i Router DC Power Supply Specifications on page 89
•
M10i DC Power Cable and Lug Specifications on page 90
M10i Router DC Power Supply Specifications
lists electrical specifications for the DC power supply.
Table 47: Electrical Specifications for DC Power Supply
Description Specification
Maximum power output
DC input voltage
Input DC current rating
293 W
Nominal: –48, –60 VDC
Operating range: –40.5 to –72 VDC
9.1 A @ –48 V
Output voltages +3.3 V @ 40 A, +2.5 V @ 20 A, +5.0 V @ 15 A, +12 V@ 3 A
NOTE: The DC power supply requires –42 VDC to power on.
NOTE: The DC power supplies are marked –48 VDC. This is the nominal voltage associated with the battery circuit. Any higher voltages are associated only with float voltages for the charging function.
Related
Documentation
•
M10i DC Power Supply Description on page 65
•
Replacing an M10i DC Power Supply on page 201
•
Replacing an M10i DC Power Cable on page 206
Copyright © 2019, Juniper Networks, Inc.
89
M10i Multiservice Edge Router Hardware Guide
•
M10i Router Power Requirements on page 82
•
M10i DC Power Cable and Lug Specifications on page 90
M10i DC Power Cable and Lug Specifications
You must provide two 14-AWG (2.08 mm
2
) single-strand-count wire cables for each power supply.
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the DC power cables that you supply. The terminal fork lugs,
14-AWG (2.08 mm
2
), are provided in the accessories box for the DC power cables.
WARNING: For field-wiring connections, use copper conductors only.
shows how to attach the power cables. The DC power cables insert into the field-wiring terminals located on each power supply—the input terminal is labeled
-48V and the return terminal is labeled RTN .
Figure 24: DC Power Cable Connections
90 Copyright © 2019, Juniper Networks, Inc.
Chapter 11: DC Power Requirements and Specifications
NOTE: DC power cables must not block access to router components or drape where people could trip on them.
The DC power supplies in slots P/S 0 and P/S 1 must be powered by dedicated power feeds derived from feed A, and the DC power supplies in slots P/S 2 and P/S 3 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system. Most sites distribute DC power through a main conduit that leads to frame-mounted DC power distribution panels, one of which might be located at the top of the rack that houses the router. A pair of cables
(one input and one return) connects the field-wiring terminals to the power distribution panel.
Related
Documentation
•
M10i DC Power Supply Description on page 65
•
Connecting Power on an DC-Powered M10i Router on page 125
•
Disconnecting Power on an DC-Powered M10i Router on page 209
Copyright © 2019, Juniper Networks, Inc.
91
M10i Multiservice Edge Router Hardware Guide
92 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 12
Network Cable and Transceiver Planning
•
Attenuation and Dispersion in Fiber-Optic Cable on M Series, MX Series, and T Series
•
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable for M10i
•
Calculating Power Budget for Fiber-Optic Cable for M Series, MX Series, and T Series
•
Calculating Power Margin for Fiber-Optic Cable for M Series, MX Series, and T Series
Attenuation and Dispersion in Fiber-Optic Cable on M Series, MX Series, and T Series
Routers
Correct functioning of an optical data link depends on modulated light reaching the receiver with enough power to be demodulated correctly.
Attenuation is the reduction in power of the light signal as it is transmitted. Attenuation is caused by passive media components, such as cables, cable splices, and connectors. While attenuation is significantly lower for optical fiber than for other media, it still occurs in both multimode and single-mode transmission. An efficient optical data link must have enough light available to overcome attenuation.
Dispersion is the spreading of the signal in time. The following two types of dispersion can affect an optical data link:
• Chromatic dispersion—Spreading of the signal in time resulting from the different speeds of light rays.
• Modal dispersion—Spreading of the signal in time resulting from the different propagation modes in the fiber.
For multimode transmission, modal dispersion, rather than chromatic dispersion or attenuation, usually limits the maximum bit rate and link length. For single-mode transmission, modal dispersion is not a factor. However, at higher bit rates and over longer distances, chromatic dispersion rather than modal dispersion limits maximum link length.
An efficient optical data link must have enough light to exceed the minimum power that the receiver requires to operate within its specifications. In addition, the total dispersion must be less than the limits specified for the type of link in Telcordia Technologies
Copyright © 2019, Juniper Networks, Inc.
93
M10i Multiservice Edge Router Hardware Guide document GR-253-CORE (Section 4.3) and International Telecommunications Union
(ITU) document G.957.
When chromatic dispersion is at the maximum allowed, its effect can be considered as a power penalty in the power budget. The optical power budget must allow for the sum of component attenuation, power penalties (including those from dispersion), and a safety margin for unexpected losses.
Related
Documentation
•
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable for M10i Routers on page 94
•
Calculating Power Budget for Fiber-Optic Cable for M Series, MX Series, and T Series
•
Calculating Power Margin for Fiber-Optic Cable for M Series, MX Series, and T Series
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable for M10i Routers
Multimode fiber is large enough in diameter to allow rays of light to reflect internally
(bounce off the walls of the fiber). Interfaces with multimode optics typically use LEDs as light sources. LEDs are not coherent sources, however. They spray varying wavelengths of light into the multimode fiber, which reflects the light at different angles. Light rays travel in jagged lines through a multimode fiber, causing signal dispersion. When light traveling in the fiber core radiates into the fiber cladding, higher-order mode loss (HOL) results. Together these factors limit the transmission distance of multimode fiber compared to single-mode fiber.
Single-mode fiber is so small in diameter that rays of light can reflect internally through one layer only. Interfaces with single-mode optics use lasers as light sources. Lasers generate a single wavelength of light, which travels in a straight line through the single-mode fiber. Compared with multimode fiber, single-mode fiber has higher bandwidth and can carry signals for longer distances. It is consequently more expensive.
The router uses optical lasers for SONET/SDH PIC single-mode interfaces. These optics comply with IR-1 of Bellcore GR-253-CORE Issue 2, December 1995 and ANSI TI.105.06.
For information about the maximum transmission distances and wavelength ranges supported by multimode and single-mode (ATM and SONET/SDH) PIC interfaces, see the interface module reference for your device. Exceeding the maximum transmission distances can result in significant signal loss, which causes unreliable transmission.
Related
Documentation
•
Attenuation and Dispersion in Fiber-Optic Cable on M Series, MX Series, and T Series
•
Calculating Power Budget for Fiber-Optic Cable for M Series, MX Series, and T Series
•
Calculating Power Margin for Fiber-Optic Cable for M Series, MX Series, and T Series
94 Copyright © 2019, Juniper Networks, Inc.
Chapter 12: Network Cable and Transceiver Planning
Calculating Power Budget for Fiber-Optic Cable for M Series, MX Series, and T Series
Routers
To ensure that fiber-optic connections have sufficient power for correct operation, you need to calculate the link's power budget, which is the maximum amount of power it can transmit. When you calculate the power budget, you use a worst-case analysis to provide a margin of error, even though all the parts of an actual system do not operate at the worst-case levels. To calculate the worst-case estimate of power budget ( P
B
), you assume minimum transmitter power ( P
T
) and minimum receiver sensitivity ( P
R
):
P
B
= P
T
– P
R
The following hypothetical power budget equation uses values measured in decibels
(dB) and decibels referred to one milliwatt (dBm):
P
B
= P
T
– P
R
P
B
= –15 dBm – (–28 dBm)
P
B
= 13 dB
Related
Documentation
•
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable for M10i Routers on page 94
•
Attenuation and Dispersion in Fiber-Optic Cable on M Series, MX Series, and T Series
•
Calculating Power Margin for Fiber-Optic Cable for M Series, MX Series, and T Series
Calculating Power Margin for Fiber-Optic Cable for M Series, MX Series, and T Series
Routers
After calculating a link's power budget you can calculate the power margin ( P
M
), which represents the amount of power available after subtracting attenuation or link loss ( LL ) from the power budget ( P
B
). A worst-case estimate of P
M assumes maximum LL :
P
M
= P
B
– LL
A P
M greater than zero indicates that the power budget is sufficient to operate the receiver.
Factors that can cause link loss include higher-order mode losses (HOL), modal and chromatic dispersion, connectors, splices, and fiber attenuation.
lists an estimated amount of loss for the factors used in the following sample calculations.
For information about the actual amount of signal loss caused by equipment and other factors, refer to vendor documentation.
Copyright © 2019, Juniper Networks, Inc.
95
M10i Multiservice Edge Router Hardware Guide
96
Table 48: Estimated Values for Factors Causing Link Loss
Link-Loss Factor Estimated Link-Loss Value
Higher-order mode losses Single-mode—None
Multimode—0.5 dB
Modal and chromatic dispersion
Connector
Splice
Fiber attenuation
Single-mode—None
Multimode—None, if product of bandwidth and distance is less than 500 MHz-km
0.5 dB
0.5 dB
Single-mode—0.5 dB/km
Multimode—1 dB/km
The following example uses the estimated values in
to calculate link loss ( LL ) for a 2-km-long multimode link with a power budget ( P
B
) of 13 dB:
• Fiber attenuation for 2 km @ 1.0 dB/km= 2 dB
• Loss for five connectors @ 0.5 dB per connector = 5(0.5 dB) = 2.5 dB
• Loss for two splices @ 0.5 dB per splice =2(0.5 dB) = 1 dB
• Higher-order mode loss = 0.5 dB
• Clock recovery module = 1 dB
The power margin ( P
M
) is calculated as follows:
P
M
= P
B
– LL
P
M
= 13 dB – 2 km (1.0 dB/km) – 5 (0.5 dB) – 2 (0.5 dB) – 0.5 dB [HOL] – 1 dB [CRM]
P
M
= 13 dB – 2 dB – 2.5 dB – 1 dB – 0.5 dB – 1 dB
P
M
= 6 dB
The following sample calculation for an 8-km-long single-mode link with a power budget
( P
B
) of 13 dB uses the estimated values from
to calculate link loss
( LL ) as the sum of fiber attenuation (8 km @ 0.5 dB/km, or 4 dB) and loss for seven connectors (0.5 dB per connector, or 3.5 dB). The power margin ( P
M
) is calculated as follows:
P
M
= P
B
– LL
P
M
= 13 dB – 8 km (0.5 dB/km) – 7(0.5 dB)
P
M
= 13 dB – 4 dB – 3.5 dB
Copyright © 2019, Juniper Networks, Inc.
Chapter 12: Network Cable and Transceiver Planning
P
M
= 5.5 dB
In both examples, the calculated power margin is greater than zero, indicating that the link has sufficient power for transmission and does not exceed the maximum receiver input power.
Related
Documentation
•
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable for M10i Routers on page 94
•
Attenuation and Dispersion in Fiber-Optic Cable on M Series, MX Series, and T Series
•
Calculating Power Budget for Fiber-Optic Cable for M Series, MX Series, and T Series
Copyright © 2019, Juniper Networks, Inc.
97
M10i Multiservice Edge Router Hardware Guide
98 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 13
Management Cable and Transceiver
Specifications and Pinouts
•
Routing Engine Interface Cable and Wire Specifications for M10i Routers on page 99
•
RJ-45 Connector Pinouts for the M10i Routing Engine MGMT Port on page 100
•
DB-9 Connector Pinouts for the M10i Routing Engine AUX/MODEM and CONSOLE
Routing Engine Interface Cable and Wire Specifications for M10i Routers
Port
For management and service operations, you connect the Routing Engine to an external console or management network. (For more information, see
.)
lists the specifications for the cables that connect to management ports.
Table 49: Cable Specifications for Routing Engine Management Ports
Cable
Specification Cable Supplied
Maximum
Length
Router
Receptacle
DB-9 male Routing Engine console or auxiliary interface
Routing Engine
Ethernet interface
RS-232
(EIA-232) serial
One 6-ft
(1.83-m) length with DB-9/DB-9 connectors
6 ft (1.83 m)
Category 5 cable or equivalent suitable for
100Base-T operation
One 15-ft
(4.92-m) length with
RJ-45/RJ-45 connectors
328 ft (100 m) RJ-45 autosensing
Related
Documentation
•
M10i Routing Engine Description on page 21
•
Replacing an M10i Ethernet Management Cable on page 171
•
Replacing an M10i Console or Auxiliary Cable on page 171
Copyright © 2019, Juniper Networks, Inc.
99
M10i Multiservice Edge Router Hardware Guide
RJ-45 Connector Pinouts for the M10i Routing Engine MGMT Port
The port on the Routing Engine labeled MGMT is an autosensing 10/100-Mbps Ethernet
RJ-45 receptacle that accepts an Ethernet cable for connecting the Routing Engine to a management LAN (or another device that supports out-of-band management). For more information, see
“M10i Routing Engine Interface Ports” on page 29 .
describes the RJ-45 connector pinout.
Table 50: RJ-45 Connector Pinout
Pin Signal
1 TX+
4
5
2
3
6
7
8
TX-
RX+
Termination network
Termination network
RX-
Termination network
Termination network
Related
Documentation
•
M10i Routing Engine Description on page 21
•
Maintaining the M10i Routing Engine on page 222
•
Replacing the M10i Routing Engine on page 158
•
Replacing an M10i Ethernet Management Cable on page 171
•
DB-9 Connector Pinouts for the M10i Routing Engine AUX/MODEM and CONSOLE
DB-9 Connector Pinouts for the M10i Routing Engine AUX/MODEM and CONSOLE
Ports
The ports on the Routing Engine labeled AUX/MODEM and CONSOLE are DB-9 receptacles that accept RS-232 (EIA-232) cable. The AUX/MODEM port connects the Routing Engine to a laptop, modem, or other auxiliary unit, and the CONSOLE port connects it to a management console. The ports are configured as data terminal equipment (DTE). For more information, see
“M10i Routing Engine Interface Ports” on page 29 .
describes the DB-9 connector pinouts.
100 Copyright © 2019, Juniper Networks, Inc.
Chapter 13: Management Cable and Transceiver Specifications and Pinouts
7
8
5
6
9
3
4
1
2
Table 51: DB-9 Connector Pinout
Pin Signal Direction
DCD
RxD
TxD
DTR
<–
<–
–>
–>
Ground
DSR
RTS
CTS
RING
—
<–
–>
<–
<–
Description
Carrier Detect
Receive Data
Transmit Data
Data Terminal Ready
Signal Ground
Data Set Ready
Request To Send
Clear To Send
Ring Indicator
Related
Documentation
•
M10i Routing Engine Description on page 21
•
Maintaining the M10i Routing Engine on page 222
•
Replacing the M10i Routing Engine on page 158
•
Replacing an M10i Console or Auxiliary Cable on page 171
•
RJ-45 Connector Pinouts for the M10i Routing Engine MGMT Port on page 100
Copyright © 2019, Juniper Networks, Inc.
101
M10i Multiservice Edge Router Hardware Guide
102 Copyright © 2019, Juniper Networks, Inc.
PART 3
Initial Installation and Configuration
•
Installation Overview on page 105
•
Unpacking the M10i on page 107
•
Installing the M10i into a Rack on page 111
•
Connecting the M10i to Ground on page 117
•
Connecting the M10i to External Devices on page 119
•
Providing Power to the M10i on page 123
•
Configuring the Junos Software on page 131
Copyright © 2019, Juniper Networks, Inc.
103
M10i Multiservice Edge Router Hardware Guide
104 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 14
Installation Overview
•
Overview of M10i Router Installation on page 105
Overview of M10i Router Installation
After you have verified that your installation site is prepared as described in
Site Preparation Checklist” on page 75 , you are ready to unpack and install the router. It
is important to proceed through the installation process in the following order:
1.
Review the safety guidelines explained in
“General Safety Guidelines for Juniper
.
2.
Unpack the router and verify that all parts have been received.
See
“Unpacking the M10i Router” on page 107
and
“Verifying the M10i Router Parts
.
3.
If necessary, move the mounting brackets.
See
“Moving the Mounting Brackets” on page 111
.
4.
Install the router.
See
“Installing the M10i Router into a Rack” on page 113 .
5.
Connect the grounding cable.
See
“Grounding the M10i Router” on page 117 .
6.
Connect a cables to a management device.
See
“Connecting to an M10I Management Console or Auxiliary Device” on page 120
.
7.
Connect the AC power cords or DC power cables.
See
“Connecting Power on an AC-Powered M10i Router” on page 123
or
Power on an DC-Powered M10i Router” on page 125 .
Copyright © 2019, Juniper Networks, Inc.
105
M10i Multiservice Edge Router Hardware Guide
8.
Power on the router as described in
“Powering On an AC-Powered M10i Router” on page 124
or
“Powering On a DC-Powered M10i Router” on page 128
.
9.
Perform the initial system startup.
See
“Initially Configuring the M10i Router” on page 131
.
10.
Connect cables to the PICs. This can be performed either before or after the router is powered on. However, you can check the LEDs after you connect the cables if the router is powered on.
106 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 15
Unpacking the M10i
•
Tools and Parts Required to Unpack the M10i Router on page 107
•
Unpacking the M10i Router on page 107
•
Verifying the M10i Router Parts Received on page 109
Tools and Parts Required to Unpack the M10i Router
To unpack the router and prepare for installation, you need the following tools:
• Utility knife for cutting the sealing tape on the shipping carton
• Phillips (+) screwdriver, number 2
Related
Documentation
•
M10i Router Description on page 3
•
M10i Chassis Description on page 11
•
M10i Chassis Lifting Guidelines on page 269
Unpacking the M10i Router
The router is shipped in a cardboard carton, held in place with foam packing material.
The crate also contains an accessory box, the front-mounting shelf, and the Quick Start.
NOTE: The router is maximally protected inside the shipping carton. Do not unpack it until you are ready to begin installation.
To unpack the router:
1.
Move the shipping carton to a staging area as close to the installation site as possible.
2.
Position the carton so that the arrows are pointing up.
3.
Using a utility knife, cut through the sealing tape on the top seam of the carton. Open the top flaps of the carton.
Copyright © 2019, Juniper Networks, Inc.
107
M10i Multiservice Edge Router Hardware Guide
4.
Remove the accessory box and packing material from the top of the router.
5.
Open the accessory box and verify the contents against the parts inventory on the label attached to the box.
6.
Remove the router from the shipping carton.
7.
Verify the chassis components received against the packing list included with the router. A generic parts inventory appears in
“Verifying the M10i Router Parts Received” on page 109 .
8.
Save the shipping carton, packing materials, and pallet in case you later need to move or ship the router.
Figure 25: Unpacking the Router
108
Related
Documentation
•
M10i Router Description on page 3
•
M10i Router Physical Specifications on page 76
•
Installation Safety Warnings for Juniper Networks Devices on page 269
Copyright © 2019, Juniper Networks, Inc.
Chapter 15: Unpacking the M10i
Verifying the M10i Router Parts Received
A packing list is included in each shipment. Check the parts in the shipment against the items on the packing list. The packing list specifies the part numbers and descriptions of each part in your order.
If any part is missing, contact a customer service representative.
A fully configured router contains the router chassis with installed components, listed in
Table 52 on page 109 , and an accessory box, which contains the parts listed in
Table 53 on page 109 . The parts shipped with your router can vary.
Table 52: Parts List for a Fully Configured Router
Component Quantity
Fan tray
CFEB or CFEB-E
HCM
Mounting brackets
2
2
Up to 2
Up to 2
PIC
Power supply
Routing Engine
Blank panels for slots without components
Up to 8
Up to 4
Up to 2
One blank panel for each slot not occupied by a component
Table 53: Accessory Box Parts List
Part Quantity
Screws, Screw, Pan hd, Phil, 12-24 x 1/2", self-tapping
Screws, Flat Hd, Phil, 5 x 10.5mm Long, 1.6mm Pitch, self-tapping
4
4
Terminal lugs, 16-AWG to 14-AWG, #6 stud, ring terminal, vinyl insulated
2 (not used for the M10i router)
Terminal fork lugs, 14-AWG, #6, 0.25 Wide, insulation strain relieved, for DC power cables
9 are shipped, but only up to 8 are used for the M10i router (2 per each power supply)
Terminal lugs, 14-AWG, #8 stud, ring tongue, insulated 2 (not used for the M10i router)
Copyright © 2019, Juniper Networks, Inc.
109
M10i Multiservice Edge Router Hardware Guide
Table 53: Accessory Box Parts List (continued)
Part
Terminal lugs, 14-AWG, two hole for grounding
DB-9 (male) to DB-25 (female) serial adapter
Serial cable, Console, DB9F/DB9F
Label, contents, 3-1/3" x 4", M7i/M10i
Label, Accessory Kit Label, Green "Small Parts Enclosed" 1
Read me first document
JNPR Compliance Form Letter, RoHS Worldwide
1
1
Affidavit for T1 connection
Juniper Networks Product Warranty
1
1
End User License Agreement 1
Addendum, Documentation Card for Routing Platforms 1
Document sleeve
3" x 5" pink bag
9" x 12" pink bag, ESD
1
2
2
Accessory box, 19 x 12 x 3"
Ethernet cable, RJ-45/RJ-45, 4-pair stranded UTP,
Category 5E, 15'
ESD wrist strap with cable
1
1
1
1
1
1
1
Quantity
Related
Documentation
•
M10i Router Description on page 3
•
M10i Chassis Description on page 11
•
M10i Router Physical Specifications on page 76
110 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 16
Installing the M10i into a Rack
•
Tools and Parts Required to Install the M10i Router Into a Rack on page 111
•
Moving the Mounting Brackets on page 111
•
Installing the M10i Router into a Rack on page 113
Tools and Parts Required to Install the M10i Router Into a Rack
To install the chassis into a rack using a mechanical lift, you need the following tools and parts:
• Mechanical lift (recommended)
• Phillips (+) screwdrivers, numbers 1 and 2
Related
Documentation
•
Installing the M10i Router into a Rack on page 113
•
M10i Chassis Description on page 11
•
M10i Chassis Lifting Guidelines on page 269
Moving the Mounting Brackets
The router is shipped with the mounting brackets installed in the front-mounting position, as shown in
Figure 5 on page 11 . If you are center-mounting the router, you must move
the brackets. To move the mounting brackets (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
To install the mounting brackets in the center-mounting position, you must remove the fan trays: a.
Loosen the thumbscrew at the top of the fan tray faceplate, using a Phillips screwdriver if necessary.
b.
Grasp the handle on the faceplate and slide the tray about halfway out of the chassis.
Copyright © 2019, Juniper Networks, Inc.
111
M10i Multiservice Edge Router Hardware Guide c.
Place one hand under the fan tray to support it and slide the tray completely out of the chassis.
3.
Use a number 2 Phillips screwdriver to remove the screws securing the mounting brackets in the front-mounting position.
4.
Remove the mounting brackets by tilting the top of the mounting bracket away from the chassis and sliding it out of the slot at the bottom of the chassis.
5.
Insert the tab at the base of the mounting brackets at an angle into the slot at the bottom of the chassis in the center-mounting position (see
6.
Replace the screws that secure the mounting brackets to the chassis.
7.
Reinstall the fan trays: a.
Grasp the handle on the faceplate of the fan tray with one hand and place the other hand under the unit to support it. Orient the fan tray so that the thumbscrew is at the top of the tray.
b.
Slide the tray into the slot.
c.
Tighten the thumbscrew to seat the fan tray firmly in the chassis.
Figure 26: Moving the Mounting Brackets on the Chassis
112
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Tools and Parts Required to Install the M10i Router Into a Rack on page 111
•
Installing the M10i Router into a Rack on page 113
•
Installation Safety Warnings for Juniper Networks Devices on page 269
Copyright © 2019, Juniper Networks, Inc.
Chapter 16: Installing the M10i into a Rack
Installing the M10i Router into a Rack
NOTE: Using a mechanical lift to maneuver the router into the rack is recommended because of the router's size and weight. The lift must be able to accommodate the router's weight—between 57 lb (25.9 kg) and about
79 lb (35.8 kg) depending on configuration—and must fit between the support posts of the rack. If you do not use a mechanical lift, installing the chassis safely requires two people to lift and an additional person to insert the mounting screws.
If you are installing multiple routers in one rack, install the lowest one first and proceed upward in the rack.
First, perform the following prerequisite procedures:
• Verify that the router site meets the requirements described in
Preparation Checklist” on page 75 .
• Place the rack in its permanent location, allowing adequate clearance for airflow and maintenance, and secure it to the building structure. For details, see
Warnings for Juniper Networks Devices” on page 269 .
• Read the following installation safety guidelines and warnings:
•
M10i Chassis Lifting Guidelines on page 269
•
Installation Safety Warnings for Juniper Networks Devices on page 269
• Remove the router from the shipping carton, as described in
Then perform the following procedures to install the router (see
and
1.
If you are center-mounting the router, move the mounting brackets on the chassis from the front-mounting position to the center-mounting position. For instructions, see
“Moving the Mounting Brackets” on page 111 .
2.
Position the chassis at the appropriate height in the rack:
• If using a mechanical lift, load the router onto the lift, making sure it rests securely on the lift platform. Use the lift to raise the chassis to the correct height.
• If not using a mechanical lift, have one person stand behind the router and another person in front. Grasp the chassis, lift it, and position it at the correct height. Have a third person ready to install the mounting screws.
3.
Align the bottom hole in both mounting brackets with a hole in each rack rail, making sure the chassis is level.
Copyright © 2019, Juniper Networks, Inc.
113
M10i Multiservice Edge Router Hardware Guide
4.
Install a mounting screw into each of the two aligned holes. Use a Phillips screwdriver to tighten the screws.
5.
Moving up the router, install a mounting screw into the remaining holes in each mounting. At least two screws in each mounting bracket are required, at the top and bottom of the mounting bracket.
6.
Verify that the router is level.
7.
If using a mechanical lift, move it away from the rack.
8.
To continue the installation, proceed to
“Initially Configuring the M10i Router” on page 131
.
Figure 27: Installing the Chassis into a Open-Frame Rack
114 Copyright © 2019, Juniper Networks, Inc.
Chapter 16: Installing the M10i into a Rack
Figure 28: Installing the Chassis into a Four-Post Rack
Related
Documentation
•
M10i Rack Size and Strength on page 77
•
M10i Chassis Description on page 11
•
M10i Chassis Lifting Guidelines on page 269
Copyright © 2019, Juniper Networks, Inc.
115
M10i Multiservice Edge Router Hardware Guide
116 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 17
Connecting the M10i to Ground
•
Grounding the M10i Router on page 117
Grounding the M10i Router
You must provide the grounding cable. For grounding cable specifications, see
Chassis Grounding Cable and Lug Specifications” on page 81
. To connect the grounding cable:
1.
Verify that a licensed electrician has attached the two-hole cable lug provided with the router to the grounding cable.
2.
Connect the grounding cable to a proper earth ground.
3.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
4.
Using a number 2 Phillips screwdriver, remove the screws next to the grounding symbol above the power supplies on the chassis rear (see
). Secure the grounding cable lug to the chosen grounding point by reinstalling and tightening the screws.
5.
Verify that the grounding cable is connected correctly, that it does not touch or block access to router components, and that it does not drape where people could trip on it.
Copyright © 2019, Juniper Networks, Inc.
117
M10i Multiservice Edge Router Hardware Guide
Figure 29: Connecting the Grounding Cable
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Router Site Preparation Checklist on page 75
•
Connecting Power on an AC-Powered M10i Router on page 123
•
Connecting Power on an DC-Powered M10i Router on page 125
118 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 18
Connecting the M10i to External Devices
•
Connecting the M10i Router to External Devices on page 119
•
Connecting the M10i Router to a Network for Out-of-Band Management on page 119
•
Connecting to an M10I Management Console or Auxiliary Device on page 120
•
Connecting M10i PIC Cables on page 121
Connecting the M10i Router to External Devices
After you have grounded the M10i router, you can connect the following external devices:
• An external console or auxiliary device to the CONSOLE port on the Routing Engine.
See
“Connecting to an M10I Management Console or Auxiliary Device” on page 120
• A laptop, modem, or other auxiliary device to the AUX/MODEM port on the Routing
Engine.
See
“Connecting to an M10I Management Console or Auxiliary Device” on page 120 .
• A management network to the MGMT port on the Routing Engine.
See
“Connecting the M10i Router to a Network for Out-of-Band Management” on page 119 .
Related
Documentation
•
M10i Chassis Description on page 11
•
M10i Routing Engine 400 Description on page 23
•
M10i Routing Engine 850 Description on page 25
•
M10i Routing Engine Interface Ports on page 29
Connecting the M10i Router to a Network for Out-of-Band Management
To connect the Routing Engine to a network for out-of-band management, connect an
Ethernet cable with RJ-45/RJ-45 connectors to the MGMT port on the Routing Engine.
One such cable is provided with the router. For cable specifications, see
Interface Cable and Wire Specifications for M10i Routers” on page 99 :
1.
Turn off the power to the management device.
Copyright © 2019, Juniper Networks, Inc.
119
M10i Multiservice Edge Router Hardware Guide
2.
Plug one end of the Ethernet cable (
shows the connector) into the MGMT port on the Routing Engine (see
3.
Plug the other end of the cable into the network device.
Figure 30: Routing Engine Ethernet Cable Connector
Figure 31: Routing Engine Management Ports
Related
Documentation
•
M10i Chassis Description on page 11
•
M10i Routing Engine 400 Description on page 23
•
M10i Routing Engine 850 Description on page 25
•
M10i Routing Engine Interface Ports on page 29
Connecting to an M10I Management Console or Auxiliary Device
To use a system console to configure and manage the Routing Engine, connect it to the
CONSOLE port on the Routing Engine. To use a laptop, modem, or other auxiliary device, connect it to the appropriate AUX/MODEM port on the Routing Engine. Both ports accept an RS-232 (EIA-232) serial cable with DB-9/DB-9 connectors. One cable is provided with the router. If you want to connect a device to both ports, you must supply another cable. See
“Routing Engine Interface Cable and Wire Specifications for M10i Routers” on page 99
. To connect a management console or auxiliary device:
1.
Turn off the power to the console or auxiliary device.
2.
Plug the female end (shown in
) of the provided console cable into the CONSOLE or AUX/MODEM port (see
NOTE:
For console devices, configure the serial port to the following values:
• Baud rate—9600
• Parity—N
• Data bits—8
• Stop bits—1
• Flow control—none
120 Copyright © 2019, Juniper Networks, Inc.
Chapter 18: Connecting the M10i to External Devices
3.
Using a 2.5 mm flat-blade screwdriver, tighten the screws on the connector.
4.
Attach the other end of the cable to the console or auxiliary device.
Figure 32: Console and Auxiliary Serial Port Connector
Figure 33: Routing Engine Management Ports
Related
Documentation
•
M10i Chassis Description on page 11
•
M10i Routing Engine 400 Description on page 23
•
M10i Routing Engine 850 Description on page 25
•
M10i Routing Engine Interface Ports on page 29
Connecting M10i PIC Cables
Now connect PICs to the network by plugging in network cable. To connect cable to the
PICs (see
Figure 34 on page 122 , which shows a fiber-optic PIC):
1.
Have ready a length of the type of cable used by the PIC. For cable specifications, see the M10i Multiservice Edge Router Interface Module Reference .
2.
If the PIC cable connector port is covered by a rubber safety plug, remove the plug.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
Copyright © 2019, Juniper Networks, Inc.
121
M10i Multiservice Edge Router Hardware Guide
3.
Insert the cable connector into the cable connector port on the PIC faceplate.
4.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
Figure 34: Attaching Cable to a PIC
122
Related
Documentation
•
M10i Chassis Description on page 11
•
M10i PICs Description on page 51
•
M10i Power System Description on page 63
Copyright © 2019, Juniper Networks, Inc.
CHAPTER 19
Providing Power to the M10i
•
Tools and Parts Required to Connect the M10i Router to External Devices on page 123
•
Connecting Power on an AC-Powered M10i Router on page 123
•
Powering On an AC-Powered M10i Router on page 124
•
Connecting Power on an DC-Powered M10i Router on page 125
•
Powering On a DC-Powered M10i Router on page 128
•
Powering Off the M10i Router on page 129
Tools and Parts Required to Connect the M10i Router to External Devices
To connect the router to management devices and PICs, you need the following tools and parts:
• Phillips (+) screwdrivers, numbers 1 and 2
• Flat-blade (-) screwdrivers, 2.5 mm for the connecting to the CONSOLE port or
AUX/MODEM port on a Routing Engine and 3 mm
• Electrostatic damage (ESD) grounding wrist strap
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Connecting to an M10I Management Console or Auxiliary Device on page 120
•
Connecting the M10i Router to a Network for Out-of-Band Management on page 119
•
Connecting M10i PIC Cables on page 121
Connecting Power on an AC-Powered M10i Router
The AC power cord that plugs into the appliance inlet on the faceplate of each AC power supply provides direct connection to the external power source.
To connect AC power to the router:
1.
Verify that the power supplies are fully inserted in the chassis and the thumbscrews on their faceplates are tightened.
Copyright © 2019, Juniper Networks, Inc.
123
M10i Multiservice Edge Router Hardware Guide
2.
For each power supply, plug in the ends of the AC power cord firmly into the appliance inlet on the power supply faceplate and the external power source receptacle.
Related
Documentation
•
M10i AC Power Supply Description on page 64
•
M10i Router AC Power Supply Specifications on page 85
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Disconnecting Power on an AC-Powered M10i Router on page 208
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
Powering On an AC-Powered M10i Router
To power on the router:
1.
Verify that the power supplies are fully inserted in the chassis and the thumbscrews on their faceplates are tightened.
2.
Verify that the ends of each AC power cord are firmly plugged into the appliance inlet on the power supply faceplate and the external power source receptacle.
3.
Verify that an external management device is connected to one of the Routing Engine ports ( AUX/MODEM , CONSOLE , or MGMT ).
NOTE: The Ethernet MGMT port is not available until you complete the initial router software configuration after the router is powered on for the first time. You can monitor the startup process during the initial installation using devices connected to the AUX/MODEM or CONSOLE ports.
4.
Turn on the power to the external management device.
5.
Press the power switch on the faceplate of the power supplies in slots P/S 0 and P/S
1 to the ON ( | ) position.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as LEDs on the power supply and command display output—to indicate that the power supply is functioning normally.
Ignore error indicators that appear during the first 60 seconds.
124 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Providing Power to the M10i
NOTE: If the LED does not light after 60 seconds, verify that the power supply is properly inserted into the chassis and repeat the cable installation procedures described in
“Connecting Power on an AC-Powered M10i
.
NOTE: The Routing Engine boots as the power supply completes its startup sequence. If the Routing Engine finishes booting and you need to power off the router again, see
“Powering Off the M10i Router” on page 129
.
6.
Verify that the OUTPUT OK LED on each power supply faceplate eventually lights steadily.
7.
Press the power switch for any additional power supplies to the ON ( | ) position and verify that the OUTPUT OK LED on each power supply faceplate lights steadily.
8.
On the external management device connected to the Routing Engine, monitor the startup process to verify that the system has booted properly.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
Related
Documentation
•
M10i AC Power Supply Description on page 64
•
M10i Router AC Power Supply Specifications on page 85
•
Connecting to an M10I Management Console or Auxiliary Device on page 120
•
Connecting the M10i Router to a Network for Out-of-Band Management on page 119
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
Connecting Power on an DC-Powered M10i Router
On a DC-powered router, the DC power cables from the external DC power sources connect to field-wiring terminals on each power supply.
Connect DC power to the router by inserting power cables into the field-wiring terminals on the faceplate of each power supply. DC power cables are not supplied with the router.
For information about the required cable type, see
.
Copyright © 2019, Juniper Networks, Inc.
125
M10i Multiservice Edge Router Hardware Guide
NOTE: The router must be connected to at least two separate external DC power sources.
CAUTION: There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the DC power cables that attach to the terminal studs on the power supply faceplate. You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity.
To connect DC power to the router (see
1.
Verify that there is no power flowing from either external power source, so that the voltage across the leads of the DC power cables is 0 V. Ensure that there is no chance that the cable leads might become active during the procedure.
2.
For each power supply, verify that the power switch on the power supply faceplate is in the OFF ( O ) position.
3.
Verify that a licensed electrician has attached a listed DC power cable lug to each power source cable.
4.
Loop the DC power cables through the hook located on the faceplate to the right of the field-wiring terminals.
5.
Depending on the type of DC power cable lugs used, loosen or remove the screws on the field-wiring terminals.
6.
Insert the DC power cable lugs into the appropriate field-wiring terminals. Using a number 1 Phillips screwdriver, turn the screw on each field-wiring terminal clockwise to secure the DC power cable lug. Apply between 8 lb-in. (.9 Nm) and 9 lb-in. (1.02
Nm) of torque to each screw.
a.
Insert the positive (+) source cable into the return terminal, which is labeled RTN .
b.
Insert the negative (–) source cable into the input terminal, which is labeled –48V .
126 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Providing Power to the M10i
NOTE: The DC power supplies in slots P/S 0 and P/S 1 must be powered by dedicated power feeds derived from feed A, and the DC power supplies in slots P/S 2 and P/S 3 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
7.
Verify that the DC source power cabling and the grounding cabling are correct, that they are not touching or blocking access to router components, and that they do not drape where people could trip on them.
Figure 35: Connecting DC Power Cables to a DC Power Supply
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
•
M10i DC Power Supply Description on page 65
•
M10i Router DC Power Supply Specifications on page 89
Copyright © 2019, Juniper Networks, Inc.
127
M10i Multiservice Edge Router Hardware Guide
Powering On a DC-Powered M10i Router
To power on a DC-powered router:
1.
Verify that the power supplies are fully inserted in the chassis and the thumbscrews on their faceplates are tightened.
2.
For each power supply on a DC-powered router, verify that the source DC power cables are connected to the appropriate terminal on the power supply faceplate: the positive
(+) source cable to the return terminal (labeled RTN ) and the negative (–) source cable to the input terminal (labeled –48V ).
3.
Verify that an external management device is connected to one of the Routing Engine ports on the Routing Engine ( AUX/MODEM , CONSOLE , or MGMT ).
4.
Turn on the DC power source so that voltage flows to the router.
5.
Turn on the power to the external management device.
6.
Press the power switch for the power supplies in slots P/S 0 and P/S 1 to the ON ( | ) position. The power switch is located on the power supply faceplate.
The Routing Engine boots as the power supply completes its startup sequence. If the
Routing Engine finishes booting and you need to power off the router again, see
“Powering Off the M10i Router” on page 129
. After powering on a power supply, wait at least 60 seconds before turning it off.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as LEDs on the power supply and command display output—to indicate that the power supply is functioning normally.
Ignore error indicators that appear during the first 60 seconds.
7.
Press the power switch for any additional power supplies to the ON ( | ) position.
8.
Verify that the green OUTPUT OK LED on each power supply faceplate lights steadily.
NOTE: If the LED does not light after 60 seconds, verify that the power supply is properly inserted into the chassis and repeat the cable installation procedures described in
“Connecting Power on an DC-Powered M10i
.
9.
On the external management device connected to the Routing Engine, monitor the startup process to verify that the system has booted properly.
128 Copyright © 2019, Juniper Networks, Inc.
Chapter 19: Providing Power to the M10i
Related
Documentation
•
Connecting to an M10I Management Console or Auxiliary Device on page 120
•
Connecting the M10i Router to a Network for Out-of-Band Management on page 119
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
•
M10i DC Power Supply Description on page 65
•
M10i Router DC Power Supply Specifications on page 89
Powering Off the M10i Router
To power off the router:
1.
On an external management device connected to the Routing Engine, issue the request system halt both-routing-engines operational mode command. The command shuts down the Routing Engines cleanly, so their state information is preserved. (If the router contains only one Routing Engine, issue the request system halt command.)
NOTE: The CFEB or CFEB-E might continue forwarding traffic for approximately 5 minutes after the request system halt command has been issued.
user@host> request system halt both-routing-engines
Wait until a message appears on the console confirming that the operating system has halted.
Halt the system ? [yes,no] (no) yes
*** FINAL System shutdown message from user@host ***
System going down IMMEDIATELY
Terminated
...
syncing disks... 11 8 done
The operating system has halted.
Please press any key to reboot.
For more information about the commands, see the CLI Explorer .
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
Copyright © 2019, Juniper Networks, Inc.
129
M10i Multiservice Edge Router Hardware Guide
3.
For each power supply, press the power switch on the power supply faceplate to the
OFF ( O ) position.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
Related
Documentation
•
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
130 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 20
Configuring the Junos Software
•
Initially Configuring the M10i Router on page 131
Initially Configuring the M10i Router
The router is shipped with the Junos OS preinstalled and ready to be configured when the router is powered on. There are three copies of the software: one on a CompactFlash card (if installed) in the Routing Engine, one on the hard disk in the Routing Engine, and one on a PC card that can be inserted into the slot in the Routing Engine faceplate.
When the router boots, it first attempts to start the image on the PC card. If a PC card is not inserted into the Routing Engine or the attempt otherwise fails, the router next tries the CompactFlash card (if installed), and finally the hard disk.
You configure the router by issuing Junos OS command-line interface (CLI) commands, either on a console device attached to the CONSOLE port on the Routing Engine, or over a telnet connection to a network connected to the MGMT port on the Routing Engine.
Gather the following information before configuring the router:
• Name the router will use on the network
• Domain name the router will use
• IP address and prefix length information for the Ethernet interface
• IP address of a default router
• IP address of a DNS server
• Password for the root user
This procedure connects one router to the network but does not enable it to forward traffic. For complete information about enabling the router to forward traffic, including examples, see the Junos OS configuration guides.
To configure the software:
1.
Verify that the router is powered on, as described in
or
“Powering On a DC-Powered M10i Router” on page 128
.
2.
Log in as the root user. There is no password.
Copyright © 2019, Juniper Networks, Inc.
131
M10i Multiservice Edge Router Hardware Guide
Amnesiac <ttyd0> login: root
3.
Start the CLI.
root@% cli root>
4.
Enter configuration mode.
root> configure
Entering configuration mode.
[edit] root@#
5.
Add a password to the root administration user account. Enter a clear-text password.
For information about using an encrypted password, or an SSH public key string (DSA or RSA), see the Junos OS Administration Library .
[edit] root@# set system root-authentication plain-text-password
New password: password
Retype new password: password
6.
Create a management console user account.
[edit] root# set system login user user-name authentication plain-text-password
New Password: password
Retype new password: password
7.
Set the user account class to super-user .
[edit] root# set system login user user-name class super-user
8.
Configure the name of the router. If the name includes spaces, enclose the name in quotation marks (“ ”).
[edit] root@# set system host-name host-name
132 Copyright © 2019, Juniper Networks, Inc.
Chapter 20: Configuring the Junos Software
NOTE: The DNS server does not use the host name to resolve to the correct
IP address. This host name is used to display the name of the routing engine in the CLI. For example, this host name shows on the command line prompt when the user is logged on to the CLI: user-name @ host-name >
9.
Configure the IP address of the DNS server.
[edit] root# set system name-server address
10.
Configure the router’s domain name.
[edit] root@# set system domain-name domain-name
11.
Configure the IP address and prefix length for the router’s Ethernet interface.
[edit] root@# set interfaces fxp0 unit 0 family inet address address/prefix-length
12.
Configure the IP address of a backup router. The backup router is used while the local router is booting and if the routing process fails to start. After the routing process starts, the backup router address is removed from the local routing and forwarding tables. For more information on the backup router, see the Junos OS Administration
Library .
[edit] root# set system backup-router address
13.
(Optional) Configure the static routes to remote subnets with access to the management port. Access to the management port is limited to the local subnet. To access the management port from a remote subnet, you need to add a static route to that subnet within the routing table. For more information on static routes, see the
Junos OS Administration Library .
[edit] root# set routing-options static route remote-subnet next-hop destination-IP
retain no-readvertise
14.
Configure the telnet service at the [edit system services] hierarchy level.
[edit] set system services telnet
Copyright © 2019, Juniper Networks, Inc.
133
M10i Multiservice Edge Router Hardware Guide
134
15.
Optionally, display the configuration to verify that it is correct.
[edit] root@# show system { host-name host-name; domain-name domain-name; backup-router address; root-authentication {
authentication-method (password | public-key);
} name-server {
address;
}
} interfaces { fxp0 { unit 0 { family inet { address address/prefix-length;
}
}
}
}
16.
Commit the configuration to activate it on the router.
[edit] root@# commit
17.
Optionally, configure additional properties by adding the necessary configuration statements. Then commit the changes to activate them on the router.
[edit] root@host# commit
18.
When you have finished configuring the router, exit configuration mode.
[edit] root@host# exit root@host>
NOTE: To reinstall the Junos OS, you boot the router from the removable media. Do not insert the removable media during normal operations. The router does not operate normally when it is booted from the removable media.
When the router boots from the storage media (removable media, CompactFlash card, or hard disk) it expands its search in the /config directory of the routing platform for the
Copyright © 2019, Juniper Networks, Inc.
Chapter 20: Configuring the Junos Software following files in the following order: juniper.conf
(the main configuration file), rescue.conf
(the rescue configuration file), and juniper.conf.1
(the first rollback configuration file).
When the search finds the first configuration file that can be loaded properly, the file loads and the search ends. If none of the file can be loaded properly, the routing platform does not function properly. If the router boots from an alternate boot device, the Junos
OS displays a message indication this when you log in to the router.
Related
Documentation
• Configuring CFEB Redundancy on the M10i Router
•
Configuring the CompactFlash Card on an M10i Routing Engine on page 156
•
M10i Router Site Preparation Checklist on page 75
Copyright © 2019, Juniper Networks, Inc.
135
M10i Multiservice Edge Router Hardware Guide
136 Copyright © 2019, Juniper Networks, Inc.
PART 4
Installing and Replacing Components
•
Overview of Installing and Replacing Components on page 139
•
Replacing Chassis Components on page 141
•
Replacing Cooling System Components on page 149
•
Replacing Host Subsystem Components on page 153
•
Replacing Line Card Components on page 173
•
Replacing Power System Components on page 191
•
Replacing Switch Fabric Components on page 211
Copyright © 2019, Juniper Networks, Inc.
137
M10i Multiservice Edge Router Hardware Guide
138 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 21
Overview of Installing and Replacing
Components
•
M10i Field-Replaceable Units (FRUs) on page 139
•
Tools and Parts Required to Replace M10i Hardware Components on page 140
M10i Field-Replaceable Units (FRUs)
Field-replaceable units (FRUs) are router components that can be replaced at the customer site. Replacing most FRUs requires minimal router downtime. The router uses the following types of FRUs:
• Hot-removable and hot-insertable FRUs—You can remove and replace these components without powering down the router or disrupting the routing functions.
• Hot-pluggable FRUs—You can remove and replace these components without powering down the router, but the routing functions of the system are interrupted when the component is removed.
• FRUs that require powering off the router—You must power off the router before removing these components.
lists the FRUs for the M10i router.
Table 54: Field-Replaceable Units
Hot-Removable and
Hot-Insertable FRUs Hot-Pluggable FRUs
FRUs that Require
Powering Off the Router
Fan tray
Physical Interface Card
(PIC)
Redundant power supply
(AC or DC)
Small form-factor pluggable (SFP)
Compact Forwarding
Engine Board (CFEB)
(when swapping for an existing CFEB)
Nonredundant power supply (AC or DC)
Enhanced Compact
Forwarding Engine Board
(CFEB-E) (when swapping for an existing CFEB-E)
High-Availability Chassis
Manager (HCM)
AC power cord or DC power cable on a nonredundant power supply (AC or DC)
Routing Engine
Copyright © 2019, Juniper Networks, Inc.
139
M10i Multiservice Edge Router Hardware Guide
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 261
•
General Safety Warnings for Juniper Networks Devices on page 262
•
Guidelines for Packing M10i Components for Shipment on page 256
•
M10i Router Description on page 3
•
Contacting Customer Support on page 245
Tools and Parts Required to Replace M10i Hardware Components
To replace hardware components, you need the tools and parts listed in
Table 55: Tools and Parts Required
Tool or part Components
Electrostatic bag or antistatic mat
Electrostatic discharge (ESD) grounding wrist strap
•
•
•
•
CFEB/CFEB-E
HCM
PIC
Routing Engine
All
Flat-blade (–) screwdriver, 2.5 mm Serial cable to AUX/MODEM or CONSOLE Routing Engine port
CompactFlash card Needlenose pliers
Phillips (+) screwdrivers, numbers 1 and 2
Rubber safety cap
•
•
•
•
•
•
Fan tray
CFEB/CFEB-E
DC power cables
PIC
Power supply (AC or DC)
Routing Engine
Fiber-optic PIC or PIC cable
Related
Documentation
•
Displaying M10i Router Components and Serial Numbers on page 247
•
Guidelines for Packing M10i Components for Shipment on page 256
•
Contacting Customer Support on page 245
•
Routine Maintenance Procedures for the M10i Router on page 219
140 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 22
Replacing Chassis Components
•
Installing the M10i Cable Management System on page 141
•
Installing an M10i HCM on page 142
•
Replacing an M10i HCM on page 143
Installing the M10i Cable Management System
The cable management system organizes and supports the PIC cables to prevent damage.
To install the cable management system (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Locate the cable management racks and appropriate screws in the accessory box.
3.
Slide the cable management rack into the slots at the front of the chassis.
4.
Use a number 2 Phillips screwdriver to tighten the screws that secure the cable management system to the chassis.
Figure 36: Installing the Cable Management System
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Cable Management System Description on page 13
Copyright © 2019, Juniper Networks, Inc.
141
M10i Multiservice Edge Router Hardware Guide
•
M10i Chassis Description on page 11
Installing an M10i HCM
To install an HCM (see
and
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place one hand under the HCM to support it and grasp the handle on the faceplate with the other hand.
3.
Align the rear of the HCM with the guide rails inside the chassis and slide it in completely.
CAUTION: Align the HCM carefully with the guide rails and push it in evenly.
Damage can result if it gets lodged in the rails because of uneven movement.
4.
Place one hand under the Routing Engine to support it and grasp the handle on the faceplate with the other hand.
5.
Align the rear of the Routing Engine with the guide rails inside the chassis and slide it in completely.
CAUTION: Align the Routing Engine carefully with the guide rails and push it in evenly. Damage can result if it gets lodged in the rails because of uneven movement.
6.
Tighten the thumbscrews on the Routing Engine faceplate to secure the Routing
Engine.
7.
Issue the show chassis hardware command to verify that the HCM is functioning correctly.
142 Copyright © 2019, Juniper Networks, Inc.
Figure 37: Installing the HCM
Figure 38: Installing a Routing Engine
Chapter 22: Replacing Chassis Components
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
•
M10i High-Availability Chassis Manager (HCM) Description on page 14
•
Troubleshooting the M10i HCM on page 230
•
Removing an M10i HCM on page 143
Replacing an M10i HCM
The HCM is hot-pluggable, as described in
“M10i Field-Replaceable Units (FRUs)” on page 139
. For a description of the effect of removing an HCM, see
.
1.
Removing an M10i HCM on page 143
2.
Installing an M10i HCM on page 146
Removing an M10i HCM
To remove an HCM (see
and
Copyright © 2019, Juniper Networks, Inc.
143
M10i Multiservice Edge Router Hardware Guide
144
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
If a Routing Engine is installed in the same row as the HCM you are removing, remove the Routing Engine first. If two Routing Engines are installed, use one of the following two methods to determine which is functioning as master:
• Note which of the blue MASTER LEDs is lit on the Routing Engine faceplates.
• Issue the following CLI command. The master Routing Engine is designated Master in the Current state field: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 27 degrees C / 80 degrees F
CPU temperature 27 degrees C / 80 degrees F
DRAM 768 MB
Memory utilization 45 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 3 percent
Interrupt 0 percent
Idle 97 percent
Model RE-5.0
Serial ID 1000647001
Start time 2009-01-28 14:11:50 PST
Uptime 21 hours, 51 minutes, 16 seconds
Load averages: 1 minute 5 minute 15 minute
0.00 0.02 0.00
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
Temperature 26 degrees C / 78 degrees F
CPU temperature 27 degrees C / 80 degrees F
DRAM 1536 MB
Memory utilization 23 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 99 percent
Model RE-850
Serial ID 1000648260
Start time 2009-01-28 16:18:12 PST
Uptime 19 hours, 44 minutes, 51 seconds
3.
If you are removing the master Routing Engine and a second Routing Engine is installed, issue the following CLI command to switch mastership to the backup host module: user@host> request chassis routing-engine master switch
Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Replacing Chassis Components
NOTE: Router performance might change if the backup Routing Engine's configuration differs from the former master's configuration. For the most predictable performance, configure the two Routing Engines identically, except for parameters unique to a Routing Engine, such as the hostname defined at the [edit system] hierarchy level and the management interface
( fxp0 or equivalent) defined at the [edit interfaces] hierarchy level.
To configure Routing Engine-specific parameters and still use the same configuration on both Routing Engines, include the appropriate configuration statements under the re0 and re1 statements at the [edit groups] hierarchy level and use the apply-groups statement. For instructions, see the Junos OS Administration Library.
4.
On the console or other management device connected to the Routing Engine, enter
CLI operational mode and issue the following command to shut down the router software cleanly and preserve Routing Engine state information.
user@host> request system halt
NOTE: Wait until a message appears on the console confirming that the operating system has halted.
For more information about the command, see the CLI Explorer .
NOTE: The CFEB might continue forwarding traffic for approximately 5 minutes after the request system halt command has been issued.
5.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
6.
Loosen the thumbscrews located at each end of the Routing Engine faceplate, using a Phillips screwdriver if necessary.
7.
Grasp the handle and slide the unit about halfway out of the chassis.
CAUTION: Slide the Routing Engine straight out of the chassis. Damage can result if it gets lodged because of uneven movement.
8.
Place one hand under the Routing Engine to support it, slide it completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
Copyright © 2019, Juniper Networks, Inc.
145
M10i Multiservice Edge Router Hardware Guide
9.
Grasp the handle of the HCM and slide the unit about halfway out of the chassis.
CAUTION: Slide the HCM straight out of the chassis. Damage can result if it gets lodged because of uneven movement.
10.
Place one hand under the HCM to support it, slide it completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
Figure 39: Removing a Routing Engine
Figure 40: Removing an HCM
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
•
M10i High-Availability Chassis Manager (HCM) Description on page 14
•
Troubleshooting the M10i HCM on page 230
•
Installing an M10i HCM on page 142
Installing an M10i HCM
To install an HCM (see
and
):
146 Copyright © 2019, Juniper Networks, Inc.
Chapter 22: Replacing Chassis Components
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place one hand under the HCM to support it and grasp the handle on the faceplate with the other hand.
3.
Align the rear of the HCM with the guide rails inside the chassis and slide it in completely.
CAUTION: Align the HCM carefully with the guide rails and push it in evenly.
Damage can result if it gets lodged in the rails because of uneven movement.
4.
Place one hand under the Routing Engine to support it and grasp the handle on the faceplate with the other hand.
5.
Align the rear of the Routing Engine with the guide rails inside the chassis and slide it in completely.
CAUTION: Align the Routing Engine carefully with the guide rails and push it in evenly. Damage can result if it gets lodged in the rails because of uneven movement.
6.
Tighten the thumbscrews on the Routing Engine faceplate to secure the Routing
Engine.
7.
Issue the show chassis hardware command to verify that the HCM is functioning correctly.
Figure 41: Installing the HCM
Copyright © 2019, Juniper Networks, Inc.
147
M10i Multiservice Edge Router Hardware Guide
Figure 42: Installing a Routing Engine
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
•
M10i High-Availability Chassis Manager (HCM) Description on page 14
•
Troubleshooting the M10i HCM on page 230
•
Removing an M10i HCM on page 143
Related
Documentation
•
•
M10i High-Availability Chassis Manager (HCM) Description on page 14
•
Troubleshooting the M10i HCM on page 230
148 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 23
Replacing Cooling System Components
•
Installing an M10i Fan Tray on page 149
•
Replacing an M10i Fan Tray on page 150
Installing an M10i Fan Tray
To install a fan tray (see
):
CAUTION: For proper airflow, the primary fan tray should be installed in slot
1 , on the left rear of the chassis. The redundant fan tray should be installed in slot 0 on the right.
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Grasp the handle on the faceplate of the fan tray with one hand and place the other hand under the unit to support it. Orient the fan tray so that the thumbscrew is at the top of the tray.
3.
Slide the tray into the slot.
4.
Tighten the thumbscrew to seat the fan tray firmly in the chassis.
Copyright © 2019, Juniper Networks, Inc.
149
M10i Multiservice Edge Router Hardware Guide
Figure 43: Installing a Fan Tray
Related
Documentation
•
•
M10i Fan Tray Description on page 19
•
Troubleshooting the M10i Fan Tray on page 230
•
Maintaining the M10i Cooling System on page 221
•
Removing an M10i Fan Tray on page 150
Replacing an M10i Fan Tray
The fan trays install into the rear of the chassis, as shown in
each house eight fans and weigh approximately 4 lb (1.8 kg).
1.
Removing an M10i Fan Tray on page 150
2.
Installing an M10i Fan Tray on page 151
Removing an M10i Fan Tray
To remove a fan tray (see
CAUTION: Do not remove both fan trays for more than one minute while the router is operating. The fans are the sole source of cooling, and the router can overheat when they are absent.
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Loosen the thumbscrew at the top of the fan tray faceplate, using a Phillips screwdriver if necessary.
3.
Grasp the handle on the faceplate and slide the tray about halfway out of the chassis.
150 Copyright © 2019, Juniper Networks, Inc.
Chapter 23: Replacing Cooling System Components
CAUTION: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
4.
Place one hand under the fan tray to support it and slide the tray completely out of the chassis after the fans stop spinning.
Figure 44: Removing a Fan Tray
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Fan Tray Description on page 19
•
Troubleshooting the M10i Fan Tray on page 230
•
Maintaining the M10i Cooling System on page 221
•
Installing an M10i Fan Tray on page 149
Installing an M10i Fan Tray
To install a fan tray (see
):
CAUTION: For proper airflow, the primary fan tray should be installed in slot
1 , on the left rear of the chassis. The redundant fan tray should be installed in slot 0 on the right.
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Grasp the handle on the faceplate of the fan tray with one hand and place the other hand under the unit to support it. Orient the fan tray so that the thumbscrew is at the top of the tray.
Copyright © 2019, Juniper Networks, Inc.
151
M10i Multiservice Edge Router Hardware Guide
3.
Slide the tray into the slot.
4.
Tighten the thumbscrew to seat the fan tray firmly in the chassis.
Figure 45: Installing a Fan Tray
See Also •
•
M10i Fan Tray Description on page 19
•
Troubleshooting the M10i Fan Tray on page 230
•
Maintaining the M10i Cooling System on page 221
•
Removing an M10i Fan Tray on page 150
Related
Documentation
•
M10i Fan Tray Description on page 19
•
Troubleshooting the M10i Fan Tray on page 230
•
Maintaining the M10i Cooling System on page 221
152 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 24
Replacing Host Subsystem Components
•
Installing the M10i Routing Engine on page 153
•
Inserting the PC Card in an M10i Routing Engine on page 154
•
Installing the CompactFlash Card in an M10i Routing Engine on page 155
•
Configuring the CompactFlash Card on an M10i Routing Engine on page 156
•
Installing an SDRAM Module in an M10i Routing Engine on page 157
•
Replacing the M10i Routing Engine on page 158
•
Removing and Inserting the PC Card from an M10i Routing Engine on page 162
•
Replacing the CompactFlash Card in an M10i Routing Engine on page 165
•
Replacing an SDRAM Module on an M10i Routing Engine on page 167
•
Replacing the SSD on an RE-B-1800 Routing Engine on page 169
•
Replacing an M10i Ethernet Management Cable on page 171
•
Replacing an M10i Console or Auxiliary Cable on page 171
Installing the M10i Routing Engine
To install a Routing Engine (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place one hand under the Routing Engine to support it and grasp the handle on the faceplate with the other hand.
3.
Align the rear of the Routing Engine with the guide rails inside the chassis and slide it in completely.
CAUTION: Align the Routing Engine carefully with the guide rails and push it in evenly. Damage can result if the Routing Engine gets lodged in the rails because of uneven movement.
Copyright © 2019, Juniper Networks, Inc.
153
M10i Multiservice Edge Router Hardware Guide
4.
Tighten the thumbscrews on the Routing Engine faceplate to secure the Routing
Engine.
The Routing Engine might require several minutes to boot.
5.
After the Routing Engine boots, issue the show chassis routing-engine command to verify correct Routing Engine functioning.
Figure 46: Installing a Routing Engine
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Removing the M10i Routing Engine on page 159
Inserting the PC Card in an M10i Routing Engine
To insert the PC Card (see
1.
Orient the PC Card with the Juniper Networks logo facing in the direction specified on the Routing Engine faceplate. Insert the card into the slot.
2.
Press the card firmly all the way into the slot. Note that the PC Card slot might be located in a different position from that shown in
154 Copyright © 2019, Juniper Networks, Inc.
Figure 47: Inserting the PC Card
Chapter 24: Replacing Host Subsystem Components
Related
Documentation
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Removing the PC Card from an M10i Routing Engine on page 163
Installing the CompactFlash Card in an M10i Routing Engine
To install the CompactFlash card (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
If the CompactFlash card is in a PCMCIA card adapter, slide it out of the adapter.
3.
Orient the CompactFlash card with the Juniper Networks logo facing up. Slide the
CompactFlash card into the connector on the Routing Engine (see
NOTE: If there is no Juniper Networks logo on the CompactFlash card, orient the CompactFlash card so that the manufacturer’s product code sticker is facing down.
4.
Use needlenose pliers with grooved jaws to lower and secure the wire clasp.
5.
Install the Routing Engine as described in
“Installing the M10i Routing Engine” on page 153
.
Copyright © 2019, Juniper Networks, Inc.
155
M10i Multiservice Edge Router Hardware Guide
Figure 48: Inserting the CompactFlash Card
Routing Engine (front)
Wire clasp CompactFlash card
Related
Documentation
•
Installing the M10i Routing Engine on page 153
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Removing the CompactFlash Card from an M10i Routing Engine on page 165
Configuring the CompactFlash Card on an M10i Routing Engine
After installing the CompactFlash card for the first time, you must copy the software from the Routing Engine's hard disk to the CompactFlash card.
To copy software to the CompactFlash card, perform the following procedure:
1.
and
.
2.
Log into the UNIX shell on your router, and change to the /var/tmp directory.
3.
Format the CompactFlash card using the following commands: dd if=/dev/zero of=/dev/ad0 count=20
4.
On the console or other management device connected to the Routing Engine, enter
CLI operational mode and issue the following command to copy the currently running and active file system partitions on the router to standby partitions on the
CompactFlash card.
user@host> request system snapshot partition
156 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
Wait until a message appears on the console confirming that the procedure is complete.
5.
Issue the following command to reboot the router's software: user@host> request system reboot
The CompactFlash card will now be the primary boot device.
6.
You can verify correct boot order by issuing the show system boot-messages command.
The output lists the devices mounted. The CompactFlash card is located at ad0 .
Related
Documentation
• request system snapshot
• show system boot-messages
•
Installing the M10i Routing Engine on page 153
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
Installing an SDRAM Module in an M10i Routing Engine
To insert a SDRAM module onto the Routing Engine (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Remove the SDRAM module from its electrostatic bag.
3.
To open the empty SDRAM slot, press the plastic ejectors on both sides.
4.
Grasp the SDRAM module by the edges, being careful not to touch any electrical components.
5.
Pressing firmly on both ends, push the module into the slot until the ejectors return completely to the closed position.
6.
Install the Routing Engine as described in
“Installing the M10i Routing Engine” on page 153
.
You can view the SDRAM configuration and verify it was installed correctly by issuing the show chassis routing-engine command, described in
Copyright © 2019, Juniper Networks, Inc.
157
M10i Multiservice Edge Router Hardware Guide
Figure 49: Installing the SDRAM Module
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Removing an SDRAM Module from an M10i Routing Engine on page 167
Replacing the M10i Routing Engine
The Routing Engines are hot-pluggable, as described in
. If two Routing Engines are installed, removal or failure of the backup
Routing Engine does not affect router function. Removal or failure of the master Routing
Engine affects forwarding and routing depending on your high availability configuration.
For detailed information, see
“M10i Routing Engine Description” on page 21 .
NOTE: You can use RE-400 and RE-850 at the same time while upgrading to RE-B-1800.
To replace a Routing Engine, perform the following procedures:
1.
Removing the M10i Routing Engine on page 159
2.
Installing the M10i Routing Engine on page 161
158 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
Removing the M10i Routing Engine
To remove a Routing Engine (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
If two Routing Engines are installed, use one of the following two methods to determine which is functioning as master:
• Note which of the blue MASTER LEDs is lit on the Routing Engine faceplates.
• Issue the following CLI command. The master Routing Engine is designated Master in the Current state field: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 27 degrees C / 80 degrees F
CPU temperature 27 degrees C / 80 degrees F
DRAM 768 MB
Memory utilization 45 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 3 percent
Interrupt 0 percent
Idle 97 percent
Model RE-5.0
Serial ID 1000647001
Start time 2009-01-28 14:11:50 PST
Uptime 21 hours, 51 minutes, 16 seconds
Load averages: 1 minute 5 minute 15 minute
0.00 0.02 0.00
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
Temperature 26 degrees C / 78 degrees F
CPU temperature 27 degrees C / 80 degrees F
DRAM 1536 MB
Memory utilization 23 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 99 percent
Model RE-850
Serial ID 1000648260
Start time 2009-01-28 16:18:12 PST
Uptime 19 hours, 44 minutes, 51 seconds
3.
If you are removing the master Routing Engine and a second Routing Engine is installed, issue the following CLI command to switch mastership to the backup host module:
Copyright © 2019, Juniper Networks, Inc.
159
M10i Multiservice Edge Router Hardware Guide user@host> request chassis routing-engine master switch
NOTE: Router performance might change if the backup Routing Engine's configuration differs from the former master's configuration. For the most predictable performance, configure the two Routing Engines identically, except for parameters unique to a Routing Engine, such as the hostname defined at the [edit system] hierarchy level and the management interface
( fxp0 or equivalent) defined at the [edit interfaces] hierarchy level.
To configure Routing Engine-specific parameters and still use the same configuration on both Routing Engines, include the appropriate configuration statements under the re0 and re1 statements at the [edit groups] hierarchy level and use the apply-groups statement. For instructions, see the Junos OS Administration Library.
4.
On the console or other management device connected to the Routing Engine, enter
CLI operational mode and issue the following command to shut down the router software cleanly and preserve Routing Engine state information.
user@host> request system halt
NOTE: Wait until a message appears on the console confirming that the operating system has halted.
For more information about the command, see the CLI Explorer .
NOTE: The CFEB might continue forwarding traffic for approximately 5 minutes after the request system halt command has been issued.
5.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
6.
Loosen the thumbscrews located at each end of the Routing Engine faceplate, using a Phillips screwdriver if necessary.
7.
Grasp the handle and slide the unit about halfway out of the chassis.
160 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
CAUTION: Slide the Routing Engine straight out of the chassis. Damage can result if the Routing Engine gets lodged because of uneven movement.
8.
Place one hand under the Routing Engine to support it, slide it completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
Figure 50: Removing a Routing Engine
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Installing the M10i Routing Engine on page 153
Installing the M10i Routing Engine
To install a Routing Engine (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place one hand under the Routing Engine to support it and grasp the handle on the faceplate with the other hand.
3.
Align the rear of the Routing Engine with the guide rails inside the chassis and slide it in completely.
CAUTION: Align the Routing Engine carefully with the guide rails and push it in evenly. Damage can result if the Routing Engine gets lodged in the rails because of uneven movement.
Copyright © 2019, Juniper Networks, Inc.
161
M10i Multiservice Edge Router Hardware Guide
4.
Tighten the thumbscrews on the Routing Engine faceplate to secure the Routing
Engine.
The Routing Engine might require several minutes to boot.
5.
After the Routing Engine boots, issue the show chassis routing-engine command to verify correct Routing Engine functioning.
Figure 51: Installing a Routing Engine
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Removing the M10i Routing Engine on page 159
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
• Synchronizing Routing Engines
Removing and Inserting the PC Card from an M10i Routing Engine
A slot labeled PC CARD on the Routing Engine faceplate accepts a Type I PC Card, as defined in the PC Card Standard published by the Personal Computer Memory Card
International Association (PCMCIA). The router is shipped with a PC Card that contains
Junos OS. The PC Card can be used to copy Junos OS from the PC Card onto the Routing
Engine. You can also copy Junos OS from the Routing Engine onto a PC Card, for example, to create a backup copy of upgrade software that you have obtained from Juniper
Networks. Instructions for copying software to a PC Card are available at the Juniper
162 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
Networks Support Web site ( https://www.juniper.net/support/ ); after logging in, navigate to the Customer Support Center, then to the download page for Junos OS.
NOTE: The appearance and position of electronic components or the PC
Card slot on your Routing Engine might differ from the figures in this section.
These differences do not affect Routing Engine installation and removal or functionality.
NOTE: The software on a PC Card is loaded only onto the Routing Engine into which the PC Card is inserted. It is not automatically copied to the other
Routing Engine.
To remove and insert a PC Card, perform the following procedures:
•
Removing the PC Card from an M10i Routing Engine on page 163
•
Inserting the PC Card in an M10i Routing Engine on page 164
Removing the PC Card from an M10i Routing Engine
The PC Card is inserted in the slot labeled PC CARD in the Routing Engine faceplate. To remove the PC Card (see
):
1.
Press the eject button located next to the PC Card slot in the Routing Engine faceplate.
Note that the PC Card slot might be located in a different position from that shown in
2.
When the PC Card pops partially out of the slot, grasp the card and pull it straight out of the slot.
Figure 52: Removing the PC Card
Copyright © 2019, Juniper Networks, Inc.
163
M10i Multiservice Edge Router Hardware Guide
See Also •
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Inserting the PC Card in an M10i Routing Engine on page 154
Inserting the PC Card in an M10i Routing Engine
To insert the PC Card (see
1.
Orient the PC Card with the Juniper Networks logo facing in the direction specified on the Routing Engine faceplate. Insert the card into the slot.
2.
Press the card firmly all the way into the slot. Note that the PC Card slot might be located in a different position from that shown in
Figure 53: Inserting the PC Card
164
See Also •
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Removing the PC Card from an M10i Routing Engine on page 163
Related
Documentation
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
Replacing the CompactFlash Card in an M10i Routing Engine
The CompactFlash card is an optional component of the Routing Engine 400 and a standard component of the Routing Engine 850. If installed, it provides primary storage for the router. It accommodates software images, configuration files, and microcode.
To remove, install, and configure a CompactFlash card, perform the following procedures:
•
Removing the CompactFlash Card from an M10i Routing Engine on page 165
•
Installing the CompactFlash Card in an M10i Routing Engine on page 166
Removing the CompactFlash Card from an M10i Routing Engine
The CompactFlash card is located inside the Routing Engine. To remove the CompactFlash card (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Remove the Routing Engine as described in
“Replacing the M10i Routing Engine” on page 158
.
4.
Use needlenose pliers with grooved jaws to pull the wire clasp out from under the
CompactFlash card and lift it up (see
).
5.
Use the needlenose pliers to gently grasp the CompactFlash card and slide it out of the connector. Place the CompactFlash card on the antistatic mat or in the electrostatic bag.
Figure 54: Removing the CompactFlash Card
Routing Engine (front)
CompactFlash card
Wire clasp
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Routing Engine Architecture Overview on page 7
Copyright © 2019, Juniper Networks, Inc.
165
M10i Multiservice Edge Router Hardware Guide
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Installing the CompactFlash Card in an M10i Routing Engine on page 155
Installing the CompactFlash Card in an M10i Routing Engine
To install the CompactFlash card (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
If the CompactFlash card is in a PCMCIA card adapter, slide it out of the adapter.
3.
Orient the CompactFlash card with the Juniper Networks logo facing up. Slide the
CompactFlash card into the connector on the Routing Engine (see
NOTE: If there is no Juniper Networks logo on the CompactFlash card, orient the CompactFlash card so that the manufacturer’s product code sticker is facing down.
4.
Use needlenose pliers with grooved jaws to lower and secure the wire clasp.
5.
Install the Routing Engine as described in
“Installing the M10i Routing Engine” on page 153
.
Figure 55: Inserting the CompactFlash Card
Routing Engine (front)
166
Wire clasp CompactFlash card
See Also •
Installing the M10i Routing Engine on page 153
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Removing the CompactFlash Card from an M10i Routing Engine on page 165
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Installing the M10i Routing Engine on page 153
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
Replacing an SDRAM Module on an M10i Routing Engine
The SDRAM installed on the Routing Engine provides storage for the routing and forwarding tables and for other Routing Engine processes. The design of the Routing
Engine allows you to modify the SDRAM configuration by adding DIMM memory modules to or removing modules from the Routing Engine. The Routing Engine contains from one to three 168-pin DIMMs.
1.
Removing an SDRAM Module from an M10i Routing Engine on page 167
2.
Installing an SDRAM Module in an M10i Routing Engine on page 168
Removing an SDRAM Module from an M10i Routing Engine
The SDRAM modules are located on the top of the Routing Engine. To remove a SDRAM module:
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Remove the Routing Engine as described in
“Replacing the M10i Routing Engine” on page 158
.
4.
To release the SDRAM module, press the plastic ejectors on both sides of the module.
5.
Grasp the SDRAM module, being careful not to touch any electrical components on the module, and firmly pull it out of the slot on the Routing Engine.
Copyright © 2019, Juniper Networks, Inc.
167
M10i Multiservice Edge Router Hardware Guide
6.
Place the SDRAM module on the antistatic mat or in the electrostatic bag.
7.
Push the plastic ejectors to close the empty SDRAM module slot.
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Installing an SDRAM Module in an M10i Routing Engine on page 157
Installing an SDRAM Module in an M10i Routing Engine
To insert a SDRAM module onto the Routing Engine (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Remove the SDRAM module from its electrostatic bag.
3.
To open the empty SDRAM slot, press the plastic ejectors on both sides.
4.
Grasp the SDRAM module by the edges, being careful not to touch any electrical components.
5.
Pressing firmly on both ends, push the module into the slot until the ejectors return completely to the closed position.
6.
Install the Routing Engine as described in
“Installing the M10i Routing Engine” on page 153
.
You can view the SDRAM configuration and verify it was installed correctly by issuing the show chassis routing-engine command, described in
168 Copyright © 2019, Juniper Networks, Inc.
Figure 56: Installing the SDRAM Module
Chapter 24: Replacing Host Subsystem Components
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Removing an SDRAM Module from an M10i Routing Engine on page 167
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Installing the M10i Routing Engine on page 153
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
Replacing the SSD on an RE-B-1800 Routing Engine
The RE-B-1800 Routing Engine supports a solid-state drive (SSD) specified by Juniper
Networks and ships with one SSD installed.
shows the arrangement of storage drive slots on an RE-B-1800 Routing Engine.
Copyright © 2019, Juniper Networks, Inc.
169
M10i Multiservice Edge Router Hardware Guide
Figure 57: RE-B-1800 Storage Drive Slots
Auxiliary port
Handle SSD slot
Management port
Console port
USB port
The following drive has been verified to work in the RE-B-1800 Routing Engines:
• SSD SLC 64 GB
To replace a storage drive:
1.
Disable and deactivate the storage drive.
2.
Remove the storage drive.
a.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an ESD point on the appliance.
b.
Unfasten the thumbscrew that secures the access door in front of the storage drive slots, and open the door.
c.
Slide the lock on the ejector to the unlocked position.
d.
Carefully slide the drive out of the slot.
3.
Reinstall the storage drive.
a.
Carefully align the sides of the drive with the guides in the slot.
b.
Slide the drive into the slot until you feel resistance, carefully ensuring that it is correctly aligned.
c.
Close the access door and tighten the thumbscrew to secure the door.
4.
Mount the new storage drive.
Related
Documentation
•
Returning a Hardware Component to Juniper Networks, Inc. on page 253
170 Copyright © 2019, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
Replacing an M10i Ethernet Management Cable
The MGMT port on the Routing Engine accepts Ethernet cable with and RJ-45 connector.
For cable specifications, see
“Routing Engine Interface Cable and Wire Specifications for
Figure 58: Routing Engine Ethernet Cable Connector
Figure 59: Ethernet Management Port
1.
Removing a Management Ethernet Cable on page 171
2.
Installing a Management Ethernet Cable on page 171
Removing a Management Ethernet Cable
1.
Press the tab on the connector and pull the connector straight out of the port.
shows the connector.
2.
Disconnect the cable from the network device.
Installing a Management Ethernet Cable
1.
Plug one end of the replacement Ethernet cable into the MGMT port.
shows the ports on the routing engine.
2.
Plug the other end of the cable into the network device.
See Also •
Installing the M10i Routing Engine on page 153
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Replacing an M10i Console or Auxiliary Cable on page 171
Replacing an M10i Console or Auxiliary Cable
The CONSOLE and AUX ports on the Routing Engine accept an RS-232 (EIA-232) serial cable with a DB-9 connector. For cable specifications, see
Cable and Wire Specifications for M10i Routers” on page 99 .
Copyright © 2019, Juniper Networks, Inc.
171
M10i Multiservice Edge Router Hardware Guide
Figure 60: Console and Auxiliary Ports
1.
Removing an M10i Console or Auxiliary Cable on page 172
2.
Installing an M10i Console or Auxiliary Cable on page 172
Removing an M10i Console or Auxiliary Cable
To remove a cable from the CONSOLE or AUX port:
1.
Turn off the power to the console or auxiliary device.
2.
Unscrew the screws that secure the cable connector to the port, using a 2.5-mm flat-blade screwdriver if necessary.
3.
Pull the cable connector straight out of the port.
4.
Disconnect the cable from the console or auxiliary device.
Installing an M10i Console or Auxiliary Cable
1.
Plug the female end of the replacement serial cable into the CONSOLE or AUX port.
shows the ports on the Routing Engine.
2.
Tighten the screws on the connector, using a 2.5-mm flat-blade screwdriver if necessary.
3.
Power on the auxiliary or console device.
172 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 25
Replacing Line Card Components
•
Installing an M10i PIC on page 173
•
Installing an M10i PIC Cable on page 175
•
Installing an M10i SFP on page 177
•
Replacing an M10i PIC on page 179
•
Replacing an M10i PIC Cable on page 184
•
Replacing an M10i SFP on page 187
Installing an M10i PIC
To install a PIC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
If the PIC uses fiber-optic cable, verify that there is a rubber safety cap over each transceiver on the faceplate. Install a cap if necessary.
3.
Prepare the PIC for insertion into the chassis:
• For a regular PIC, hold the PIC in one hand and with your other hand pull the end of the ejector lever away from the PIC faceplate. Hold the lever out while you insert the PIC.
• For a quad-wide PIC, verify that the end of each ejector lever is pulled away from the PIC faceplate, toward the ends of the PIC.
4.
Align the rear of the PIC with the guides located at the bottom corners of the PIC slot.
5.
Slide the PIC into the slot:
• For a regular PIC, slide the PIC into the slot until about 0.5 in. (1 cm) of the PIC remains outside the slot and you feel some resistance. Release the ejector lever and gently push the PIC faceplate until you hear a click as the PIC contacts the midplane. The ejector lever engages and closes automatically.
Copyright © 2019, Juniper Networks, Inc.
173
M10i Multiservice Edge Router Hardware Guide
174
• For a quad-wide PIC, slide the PIC into the slot until it contacts the midplane. Push the ejector levers inward toward the PIC faceplate to seat the PIC securely in the chassis.
CAUTION: Slide the PIC straight into the slot to avoid damaging the components on the PIC.
6.
If the PIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
7.
Insert the appropriate cables into the cable connectors on the PIC.
8.
Arrange each cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
9.
Use one of the following methods to bring the PIC online:
• Press and hold the PIC offline button until the status LED on the PIC faceplate indicates normal functioning, which usually takes about 5 seconds. The LED is usually green; for more information, see the M10i Multiservice Edge Router Interface
Copyright © 2019, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
Module Reference . The offline button for each PIC is located on the HCM and is labeled with the PIC slot number. The PICs in FPC 0 are located on the upper HCM, and the PICs installed in FPC 1 are located on the lower HCM.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning status LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining the M10i PICs and PIC Cables” on page 223 .
Figure 61: Installing a PIC
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Connecting M10i PIC Cables on page 121
•
M10i PICs Description on page 51
•
Troubleshooting the M10i PICs on page 235
Installing an M10i PIC Cable
To install a PIC cable (see
1.
Have ready a length of the type of cable used by the PIC. For cable specifications, see the M10i Multiservice Edge Router Interface Module Reference .
2.
If the PIC cable connector port is covered by a rubber safety plug, remove the plug.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
Copyright © 2019, Juniper Networks, Inc.
175
M10i Multiservice Edge Router Hardware Guide
176
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the PIC faceplate.
4.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
5.
Insert the other end of the cable into the destination port.
6.
Repeat the previous steps for any additional cables.
7.
If the PIC is offline (its failure indicator LED is lit), use one of the following methods to bring the PIC online:
• Press and hold the PIC offline button until the status LED on the PIC faceplate indicates normal functioning, which usually takes about 5 seconds. The LED is usually green; for more information, see the M10i Multiservice Edge Router Interface
Module Reference . The offline button for each PIC is located on the HCM and is labeled with the PIC slot number. The PICs in FPC 0 are located on the upper HCM, and the PICs installed in FPC 1 are located on the lower HCM.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning indicator LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining the M10i PICs and PIC Cables” on page 223
.
Copyright © 2019, Juniper Networks, Inc.
Figure 62: Connecting Fiber-Optic Cable to a PIC
Chapter 25: Replacing Line Card Components
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Connecting M10i PIC Cables on page 121
•
M10i PICs Description on page 51
•
Troubleshooting the M10i PICs on page 235
•
Removing an M10i PIC Cable on page 184
Installing an M10i SFP
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: When handling fiber-optic transceivers and fiber-optic cable, observe the following precautions:
• Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
• Do not bend fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
• Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
Copyright © 2019, Juniper Networks, Inc.
177
M10i Multiservice Edge Router Hardware Guide
To install a replacement SFP (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Verify that a rubber safety cap covers the SFP transceiver, installing one if necessary.
3.
Orient the SFP over the port in the PIC so that the connector end will enter the slot first and the SFP connector faces the appropriate direction:
• If the PIC has ten SFP ports, the ports are arranged in two columns. The SFP connector faces to the right for ports in the left column, and to the left for ports in the right column.
• If the PIC has one or two SFP ports, the SFP connector faces to the left on platforms in which FPCs install vertically in the chassis, and faces upward on platforms in which FPCs install horizontally in the chassis.
4.
Slide the SFP into the slot. If there is resistance, remove the SFP and flip it so that the connector faces the other direction.
5.
Remove the rubber safety cap from the transceiver and the end of the cable, and insert the cable into the transceiver.
6.
Arrange the cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
7.
Verify that the status LEDs on the PIC faceplate indicate that the SFP is functioning correctly (there is an LED for each SFP port). For more information about the PIC
LEDs, see the M10i Multiservice Edge Router Interface Module Reference . You can also verify PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining the M10i PICs and PIC Cables” on page 223 .
Figure 63: Small Form-Factor Pluggable (SFP)
Connector
178
Locking pin
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i PICs Description on page 51
Copyright © 2019, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
•
Troubleshooting the M10i PICs on page 235
•
Removing an M10i SFP on page 187
Replacing an M10i PIC
Up to eight regular PICs install into an M10i router, as shown in
“M10i Chassis Description” on page 11
. Quad-wide PICs occupy all four slots in an FPC row.
PICs are hot-removable and hot-insertable. A removed PIC no longer receives or transmits data, and removing or inserting a PIC briefly interrupts forwarding of traffic through the remaining PICs.
1.
Removing an M10i PIC on page 179
2.
Installing an M10i PIC on page 181
Removing an M10i PIC
To remove a PIC (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each transceiver and cable.
3.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
4.
If the PIC has multiple cable connector ports, label the cable connected to each port, to make it easier to reconnect the cables correctly.
5.
Use one of the following methods to take the PIC offline:
• Press and hold the PIC offline button until its failure indicator LED lights, which usually takes about 5 seconds. The failure LED is usually red; for more information, see the M10i Multiservice Edge Router Interface Module Reference . The offline button for each PIC is located on the HCM and is labeled with the PIC slot number. The
PICs in FPC 0 are located on the upper HCM, and the PICs installed in FPC 1 are located on the lower HCM.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see the CLI Explorer .
6.
Disconnect the cables from the PIC. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
Copyright © 2019, Juniper Networks, Inc.
179
M10i Multiservice Edge Router Hardware Guide
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
7.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
8.
Unseat the PIC from the chassis:
• For a regular PIC, pull the right end of the PIC ejector lever away from the PIC faceplate.
• For a quad-wide PIC, pull the end of each ejector lever away from the PIC faceplate, toward the outer edges of the PIC.
9.
Grasp both sides of the PIC faceplate and slide it out of the chassis. Do not use the ejector lever as a handle.
10.
Place the PIC in the electrostatic bag or on the antistatic mat.
11.
If you are not reinstalling a PIC into the emptied slot within a short time, install a blank
PIC panel over the slot to maintain proper airflow in the chassis.
180 Copyright © 2019, Juniper Networks, Inc.
Figure 64: Removing a PIC
Chapter 25: Replacing Line Card Components
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Connecting M10i PIC Cables on page 121
•
M10i PICs Description on page 51
•
Maintaining the M10i PICs and PIC Cables on page 223
•
Troubleshooting the M10i PICs on page 235
Installing an M10i PIC
To install a PIC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
If the PIC uses fiber-optic cable, verify that there is a rubber safety cap over each transceiver on the faceplate. Install a cap if necessary.
3.
Prepare the PIC for insertion into the chassis:
• For a regular PIC, hold the PIC in one hand and with your other hand pull the end of the ejector lever away from the PIC faceplate. Hold the lever out while you insert the PIC.
• For a quad-wide PIC, verify that the end of each ejector lever is pulled away from the PIC faceplate, toward the ends of the PIC.
4.
Align the rear of the PIC with the guides located at the bottom corners of the PIC slot.
5.
Slide the PIC into the slot:
• For a regular PIC, slide the PIC into the slot until about 0.5 in. (1 cm) of the PIC remains outside the slot and you feel some resistance. Release the ejector lever and gently push the PIC faceplate until you hear a click as the PIC contacts the midplane. The ejector lever engages and closes automatically.
Copyright © 2019, Juniper Networks, Inc.
181
M10i Multiservice Edge Router Hardware Guide
182
• For a quad-wide PIC, slide the PIC into the slot until it contacts the midplane. Push the ejector levers inward toward the PIC faceplate to seat the PIC securely in the chassis.
CAUTION: Slide the PIC straight into the slot to avoid damaging the components on the PIC.
6.
If the PIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
7.
Insert the appropriate cables into the cable connectors on the PIC.
8.
Arrange each cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
9.
Use one of the following methods to bring the PIC online:
• Press and hold the PIC offline button until the status LED on the PIC faceplate indicates normal functioning, which usually takes about 5 seconds. The LED is usually green; for more information, see the M10i Multiservice Edge Router Interface
Copyright © 2019, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
Module Reference . The offline button for each PIC is located on the HCM and is labeled with the PIC slot number. The PICs in FPC 0 are located on the upper HCM, and the PICs installed in FPC 1 are located on the lower HCM.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning status LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining the M10i PICs and PIC Cables” on page 223 .
Figure 65: Installing a PIC
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Connecting M10i PIC Cables on page 121
•
M10i PICs Description on page 51
•
Troubleshooting the M10i PICs on page 235
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Connecting M10i PIC Cables on page 121
•
M10i PICs Description on page 51
•
Maintaining the M10i PICs and PIC Cables on page 223
•
Troubleshooting the M10i PICs on page 235
Copyright © 2019, Juniper Networks, Inc.
183
M10i Multiservice Edge Router Hardware Guide
Replacing an M10i PIC Cable
Removing and installing PIC cables does not affect router function, except that a PIC does not receive or transmit data while its cable is disconnected.
1.
Removing an M10i PIC Cable on page 184
2.
Installing an M10i PIC Cable on page 185
Removing an M10i PIC Cable
To remove a PIC cable:
1.
If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each cable and transceiver.
2.
If removing all cables connected to the PIC, use one of the following methods to take the PIC offline:
• Press and hold the PIC offline button until its failure indicator LED lights, which usually takes about 5 seconds. The failure LED is usually red; for more information, see the M10i Multiservice Edge Router Interface Module Reference . The offline button for each PIC is located on the HCM and is labeled with the PIC slot number. The
PICs in FPC 0 are located on the upper HCM, and the PICs installed in FPC 1 are located on the lower HCM.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see the CLI Explorer .
3.
Unplug the cable from the cable connector port. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
4.
Remove the cable from the cable management system and detach it from the destination port.
184 Copyright © 2019, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Connecting M10i PIC Cables on page 121
•
M10i PICs Description on page 51
•
Maintaining the M10i PICs and PIC Cables on page 223
•
Troubleshooting the M10i PICs on page 235
•
Installing an M10i PIC Cable on page 175
Installing an M10i PIC Cable
To install a PIC cable (see
1.
Have ready a length of the type of cable used by the PIC. For cable specifications, see the M10i Multiservice Edge Router Interface Module Reference .
2.
If the PIC cable connector port is covered by a rubber safety plug, remove the plug.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the PIC faceplate.
4.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
Copyright © 2019, Juniper Networks, Inc.
185
M10i Multiservice Edge Router Hardware Guide
5.
Insert the other end of the cable into the destination port.
6.
Repeat the previous steps for any additional cables.
7.
If the PIC is offline (its failure indicator LED is lit), use one of the following methods to bring the PIC online:
• Press and hold the PIC offline button until the status LED on the PIC faceplate indicates normal functioning, which usually takes about 5 seconds. The LED is usually green; for more information, see the M10i Multiservice Edge Router Interface
Module Reference . The offline button for each PIC is located on the HCM and is labeled with the PIC slot number. The PICs in FPC 0 are located on the upper HCM, and the PICs installed in FPC 1 are located on the lower HCM.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning indicator LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining the M10i PICs and PIC Cables” on page 223
.
Figure 66: Connecting Fiber-Optic Cable to a PIC
186
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Connecting M10i PIC Cables on page 121
•
M10i PICs Description on page 51
•
Troubleshooting the M10i PICs on page 235
•
Removing an M10i PIC Cable on page 184
Copyright © 2019, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Connecting M10i PIC Cables on page 121
•
M10i PICs Description on page 51
•
Maintaining the M10i PICs and PIC Cables on page 223
•
Troubleshooting the M10i PICs on page 235
Replacing an M10i SFP
Small form-factor pluggables (SFPs) are transceivers that can be removed from a PIC
(for more information, see
“M10i PICs Description” on page 51
).
SFPs are hot-insertable and hot-removable. Removing an SFP does not interrupt PIC functioning, but the removed SFP no longer receives or transmits data.
1.
Removing an M10i SFP on page 187
2.
Installing an M10i SFP on page 188
Removing an M10i SFP
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: When handling fiber-optic transceivers and fiber-optic cable, observe the following precautions:
• Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
• Do not bend fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
• Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
To remove an SFP (see
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
Copyright © 2019, Juniper Networks, Inc.
187
M10i Multiservice Edge Router Hardware Guide
3.
Label the cable connected to the SFP so that you can later reconnect it to the correct
SFP.
4.
Disconnect the cable from the SFP. Immediately cover the transceiver and the end of the cable with a rubber safety cap.
5.
Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
6.
Pull the ejector handle away from the SFP faceplate to unseat the SFP from the PIC.
Pull the SFP out of the PIC and place it on the antistatic mat or in the electrostatic bag.
CAUTION: After removing a transceiver from the chassis, wait at least 30 seconds before reinserting it or inserting a transceiver into a different slot.
Figure 67: Small Form-Factor Pluggable (SFP)
Connector
Locking pin
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i PICs Description on page 51
•
Troubleshooting the M10i PICs on page 235
•
Installing an M10i SFP on page 177
Installing an M10i SFP
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
188 Copyright © 2019, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
CAUTION: When handling fiber-optic transceivers and fiber-optic cable, observe the following precautions:
• Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
• Do not bend fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
• Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
To install a replacement SFP (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Verify that a rubber safety cap covers the SFP transceiver, installing one if necessary.
3.
Orient the SFP over the port in the PIC so that the connector end will enter the slot first and the SFP connector faces the appropriate direction:
• If the PIC has ten SFP ports, the ports are arranged in two columns. The SFP connector faces to the right for ports in the left column, and to the left for ports in the right column.
• If the PIC has one or two SFP ports, the SFP connector faces to the left on platforms in which FPCs install vertically in the chassis, and faces upward on platforms in which FPCs install horizontally in the chassis.
4.
Slide the SFP into the slot. If there is resistance, remove the SFP and flip it so that the connector faces the other direction.
5.
Remove the rubber safety cap from the transceiver and the end of the cable, and insert the cable into the transceiver.
6.
Arrange the cable in the cable management system to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
7.
Verify that the status LEDs on the PIC faceplate indicate that the SFP is functioning correctly (there is an LED for each SFP port). For more information about the PIC
LEDs, see the M10i Multiservice Edge Router Interface Module Reference . You can also
Copyright © 2019, Juniper Networks, Inc.
189
M10i Multiservice Edge Router Hardware Guide verify PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining the M10i PICs and PIC Cables” on page 223 .
Figure 68: Small Form-Factor Pluggable (SFP)
Connector
Locking pin
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i PICs Description on page 51
•
Troubleshooting the M10i PICs on page 235
•
Removing an M10i SFP on page 187
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i PICs Description on page 51
•
Troubleshooting the M10i PICs on page 235
190 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 26
Replacing Power System Components
•
Installing an M10i AC Power Supply on page 191
•
Installing an M10i DC Power Supply on page 193
•
Replacing an M10i AC Power Supply on page 195
•
Replacing an M10i AC Power Cord on page 199
•
Replacing an M10i DC Power Supply on page 201
•
Replacing an M10i DC Power Cable on page 206
•
Disconnecting Power on an AC-Powered M10i Router on page 208
•
Disconnecting Power on an DC-Powered M10i Router on page 209
Installing an M10i AC Power Supply
To install an AC power supply (see
):
1.
Verify that the switch on the power supply faceplate is in the OFF ( O ) position.
2.
Locate the AC power cord shipped with the router, which should be appropriate for your geographical location (see
“M10i AC Power Cord Specifications” on page 86
).
3.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
4.
Grasp the handle on the power supply faceplate with one hand and place the other hand under the supply to support it.
5.
Align the rear of the supply with the slide guides inside the chassis and slide the supply into the chassis until it contacts the midplane.
6.
Tighten (but do not overtighten) the thumbscrews on the power supply faceplate.
7.
Insert the appliance coupler end of the AC power cord into the appliance inlet on the power supply faceplate and insert the plug into an AC power source receptacle. Verify
Copyright © 2019, Juniper Networks, Inc.
191
M10i Multiservice Edge Router Hardware Guide that the AC power cord does not block access to router components or drape where people could trip on it.
8.
Press the power switch on the faceplate to the ON ( | ) position. When the power supply has powered on successfully, the green OUTPUT OK LED lights steadily.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on. After powering on a power supply, wait at least 60 seconds before turning it off.
If the router is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. If the Routing Engine finishes booting and you need to power off the router again, see
“Powering Off the M10i Router” on page 129
.
After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the output status LED on the power supply, the command display output, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
Figure 69: Installing an AC Power Supply
192
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
•
M10i Router Power Requirements on page 82
•
Maintaining the M10i Power Supplies on page 224
•
Troubleshooting the M10i Power System on page 237
•
Removing an M10i AC Power Supply on page 196
Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Installing an M10i DC Power Supply
To install a DC power supply (see
and
1.
Verify that there is no power flowing to the power supply from the external power source, so that the voltage across the leads of the DC power cables is 0 V. Ensure that there is no chance that the cable leads might become active during the procedure.
2.
Verify that the power switch for the power supply (located on the power supply faceplate) is in the OFF ( O ) position.
3.
Verify that the grounding cable is attached to the chassis and properly connected to an earth ground.
4.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
5.
Grasp the handle on the power supply faceplate with one hand and place the other hand under the supply to support it.
6.
Align the rear of the supply with the slide guides inside the chassis and slide the supply into the chassis until it contacts the midplane.
7.
Tighten (but do not overtighten) the thumbscrews on the power supply faceplate.
8.
Verify that a licensed electrician has attached a listed DC power cable lug to each power source cable.
9.
Loop the DC power cables through the hook located on the faceplate to the right of the field-wiring terminals.
10.
Depending on the type of DC power cable lugs used, loosen or remove the screws on the field-wiring terminals.
11.
Insert the DC power cable lugs into the appropriate field-wiring terminals. Using a number 1 Phillips screwdriver, turn the screw on each field-wiring terminal clockwise to secure the DC power cable lug. Apply between 8 lb-in. (.9 Nm) and 9 lb-in. (1.02
Nm) of torque to each screw.
a.
Insert the positive (+) source cable into the return terminal, which is labeled RTN .
b.
Insert the negative (–) source cable into the input terminal, which is labeled –48V .
Copyright © 2019, Juniper Networks, Inc.
193
M10i Multiservice Edge Router Hardware Guide
NOTE: The DC power supplies in slots P/S 0 and P/S 1 must be powered by dedicated power feeds derived from feed A, and the DC power supplies in slots P/S 2 and P/S 3 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
12.
Verify that the DC source power cabling is correct, that the DC power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
13.
Turn on the DC power source so that voltage flows to the power supply.
14.
Press the switch on the power supply faceplate to the ON ( | ) position. When the power supply has powered on successfully, the green OUTPUT OK LED lights steadily.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on. After powering on a power supply, wait at least 60 seconds before turning it off.
If the router is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. If the Routing Engine finishes booting and you need to power off the router again, see
“Powering Off the M10i Router” on page 129
.
After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the output status LED on the power supply, the command display output, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
Figure 70: Installing a DC Power Supply
194 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Figure 71: Connecting DC Power Cables to a DC Power Supply
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i DC Power Supply Description on page 65
•
M10i Router Power Requirements on page 82
•
Maintaining the M10i Power Supplies on page 224
•
Troubleshooting the M10i Power System on page 237
•
Removing an M10i DC Power Supply on page 201
Replacing an M10i AC Power Supply
An AC-powered router has up to three load-sharing AC power supplies. The router must have at least two AC power supplies, and any two AC power supplies can provide full power to the router. Three power supplies are required for redundancy. A redundant power supply is hot-removable and hot-insertable, as described in
. For M10i routers with only two AC power supplies, you must power off the router before replacing an AC power supply.
1.
Removing an M10i AC Power Supply on page 196
2.
Installing an M10i AC Power Supply on page 197
Copyright © 2019, Juniper Networks, Inc.
195
M10i Multiservice Edge Router Hardware Guide
Removing an M10i AC Power Supply
The AC power supplies are located at the bottom rear of the chassis, as shown in
Chassis Description” on page 11
. For information about power supply redundancy and replaceability, see
“M10i Power System Description” on page 63
.
CAUTION: Do not leave a power supply slot empty for more than a short time while the router is operational. The power supply must remain in the chassis for proper airflow.
To remove an AC power supply (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Press the power switch on the power supply faceplate to the OFF ( O ) position.
NOTE: If you are not removing the power supply, but simply powering it off, wait at least 60 seconds before turning it back on. If you need to power it off again, wait for at least 60 seconds after powering it on.
3.
Unplug the AC power cord from the appliance inlet on the faceplate.
4.
Loosen the thumbscrew at each end of the power supply faceplate, using a Phillips screwdriver if necessary.
5.
Grasp the handle on the power supply faceplate and pull firmly to slide the unit about halfway out of the chassis.
6.
Place one hand under the power supply to support it, then slide it completely out of the chassis.
196 Copyright © 2019, Juniper Networks, Inc.
Figure 72: Removing an AC Power Supply
Chapter 26: Replacing Power System Components
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
•
M10i Router Power Requirements on page 82
•
Maintaining the M10i Power Supplies on page 224
•
Troubleshooting the M10i Power System on page 237
•
Installing an M10i AC Power Supply on page 191
Installing an M10i AC Power Supply
To install an AC power supply (see
):
1.
Verify that the switch on the power supply faceplate is in the OFF ( O ) position.
2.
Locate the AC power cord shipped with the router, which should be appropriate for your geographical location (see
“M10i AC Power Cord Specifications” on page 86
).
3.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
4.
Grasp the handle on the power supply faceplate with one hand and place the other hand under the supply to support it.
5.
Align the rear of the supply with the slide guides inside the chassis and slide the supply into the chassis until it contacts the midplane.
6.
Tighten (but do not overtighten) the thumbscrews on the power supply faceplate.
Copyright © 2019, Juniper Networks, Inc.
197
M10i Multiservice Edge Router Hardware Guide
7.
Insert the appliance coupler end of the AC power cord into the appliance inlet on the power supply faceplate and insert the plug into an AC power source receptacle. Verify that the AC power cord does not block access to router components or drape where people could trip on it.
8.
Press the power switch on the faceplate to the ON ( | ) position. When the power supply has powered on successfully, the green OUTPUT OK LED lights steadily.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on. After powering on a power supply, wait at least 60 seconds before turning it off.
If the router is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. If the Routing Engine finishes booting and you need to power off the router again, see
“Powering Off the M10i Router” on page 129
.
After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the output status LED on the power supply, the command display output, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
Figure 73: Installing an AC Power Supply
198
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
•
M10i Router Power Requirements on page 82
•
Maintaining the M10i Power Supplies on page 224
•
Troubleshooting the M10i Power System on page 237
•
Removing an M10i AC Power Supply on page 196
Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
•
M10i Router Power Requirements on page 82
•
Maintaining the M10i Power Supplies on page 224
•
Troubleshooting the M10i Power System on page 237
Replacing an M10i AC Power Cord
An AC-powered router has up to three load-sharing AC power supplies. The router must have at least two AC power supplies, and any two AC power supplies can provide full power to the router. Three power supplies are required for redundancy. An AC power cord on a redundant power supply is hot-removable and hot-insertable, as described in
Field-Replaceable Units (FRUs)” on page 139
. For M10i routers with only two AC power supplies, you must power off the router before replacing an AC power cord.
1.
Removing an M10i AC Power Cord on page 199
2.
Installing an M10i AC Power Cord on page 200
Removing an M10i AC Power Cord
To remove an AC power cord:
1.
Switch off the dedicated customer site circuit breaker for the power supply, and remove the power cord from the AC power source. Follow the instructions for your site.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
3.
Switch the power switch on the power supply faceplate to the OFF ( O ) position.
4.
Remove the appliance coupler end of a AC power cord from the appliance inlet on the power supply faceplate.
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i AC Power Supply Description on page 64
•
Maintaining the M10i Power Supplies on page 224
•
Troubleshooting the M10i Power System on page 237
Copyright © 2019, Juniper Networks, Inc.
199
M10i Multiservice Edge Router Hardware Guide
Installing an M10i AC Power Cord
To install an AC power cord:
1.
Locate an AC power cord with a plug appropriate for your geographical location (see
“M10i AC Power Cord Specifications” on page 86 ).
2.
Verify that the power switch on the power supply faceplate is in the OFF ( O ) position.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Insert the appliance coupler end of a AC power cord into the appliance inlet on a power supply faceplate.
5.
Detach the ESD grounding strap from the ESD points on the chassis, and connect the strap to an approved site ESD grounding point. Follow the instructions for your site.
6.
Switch on the dedicated customer site circuit breaker for the power supply, and insert the plug into an AC power source receptacle. Follow the instructions for your site.
7.
Detach the ESD grounding strap from the approved site ESD grounding point, and connect the strap to the ESD points on the chassis.
8.
Switch the power switch on the power supply to the on (|) position.
9.
Observe the OUTPUT OK LEDs on the AC power supply faceplate. If the power supply is correctly installed and functioning normally, the OUTPUT OK lights steadily.
10.
Verify that the AC power cord does not block access to router components or drape where people could trip on it.
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i AC Power Supply Description on page 64
•
M10i Router Power Requirements on page 82
•
Maintaining the M10i Power Supplies on page 224
•
Troubleshooting the M10i Power System on page 237
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i AC Power Supply Description on page 64
•
Maintaining the M10i Power Supplies on page 224
200 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
•
Troubleshooting the M10i Power System on page 237
Replacing an M10i DC Power Supply
A DC-powered router has up to four load-sharing DC power supplies. The router must have at least two DC power supplies, and any two DC power supplies can provide full power to the router. Each redundant power supply is hot-removable and hot-insertable, as described in
“M10i Field-Replaceable Units (FRUs)” on page 139 . For M10i routers with
only two DC power supplies, you must power off the router before replacing a DC power supply.
1.
Removing an M10i DC Power Supply on page 201
2.
Installing an M10i DC Power Supply on page 202
Removing an M10i DC Power Supply
The DC power supplies are located at the bottom rear of the chassis, as shown in
Chassis Description” on page 11
. For information about power supply redundancy and replaceability, see
“M10i Power System Description” on page 63
.
CAUTION: Do not leave a power supply slot empty for more than a short time while the router is operational. The power supply must remain in the chassis for proper airflow.
To remove a DC power supply (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Press the power switch for the power supply (located on the power supply faceplate) to the OFF ( O ) position.
NOTE: If you are power cycling the power supply rather than shutting it off for a time, wait at least 60 seconds after turning it off before turning it back on. If you need to power it off again, wait for at least 60 seconds after powering it on.
3.
Shut off the power flowing to the power supply from the external power source, so that the voltage across the leads of the DC power cables is 0 V. Ensure that there is no chance that the cable leads might become active during the procedure.
4.
Using a number 1 Phillips screwdriver, turn the screw on each field-wiring terminal counter-clockwise to loosen the terminal connector from around the cable lug.
Copyright © 2019, Juniper Networks, Inc.
201
M10i Multiservice Edge Router Hardware Guide
5.
Remove the cables from the terminal connectors and from the hook located on the faceplate to the right of the field-wiring terminals.
6.
Loosen the thumbscrew at each end of the power supply faceplate, using a Phillips screwdriver if necessary.
7.
Grasp the handle on the power supply faceplate and pull firmly to slide the unit about halfway out of the chassis.
8.
Place one hand under the power supply to support it, then slide it completely out of the chassis.
Figure 74: Removing a DC Power Supply
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Router Power Requirements on page 82
•
Maintaining the M10i Power Supplies on page 224
•
Troubleshooting the M10i Power System on page 237
•
Installing an M10i DC Power Supply on page 193
Installing an M10i DC Power Supply
To install a DC power supply (see
and
1.
Verify that there is no power flowing to the power supply from the external power source, so that the voltage across the leads of the DC power cables is 0 V. Ensure that there is no chance that the cable leads might become active during the procedure.
2.
Verify that the power switch for the power supply (located on the power supply faceplate) is in the OFF ( O ) position.
202 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
3.
Verify that the grounding cable is attached to the chassis and properly connected to an earth ground.
4.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
5.
Grasp the handle on the power supply faceplate with one hand and place the other hand under the supply to support it.
6.
Align the rear of the supply with the slide guides inside the chassis and slide the supply into the chassis until it contacts the midplane.
7.
Tighten (but do not overtighten) the thumbscrews on the power supply faceplate.
8.
Verify that a licensed electrician has attached a listed DC power cable lug to each power source cable.
9.
Loop the DC power cables through the hook located on the faceplate to the right of the field-wiring terminals.
10.
Depending on the type of DC power cable lugs used, loosen or remove the screws on the field-wiring terminals.
11.
Insert the DC power cable lugs into the appropriate field-wiring terminals. Using a number 1 Phillips screwdriver, turn the screw on each field-wiring terminal clockwise to secure the DC power cable lug. Apply between 8 lb-in. (.9 Nm) and 9 lb-in. (1.02
Nm) of torque to each screw.
a.
Insert the positive (+) source cable into the return terminal, which is labeled RTN .
b.
Insert the negative (–) source cable into the input terminal, which is labeled –48V .
NOTE: The DC power supplies in slots P/S 0 and P/S 1 must be powered by dedicated power feeds derived from feed A, and the DC power supplies in slots P/S 2 and P/S 3 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
12.
Verify that the DC source power cabling is correct, that the DC power cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
Copyright © 2019, Juniper Networks, Inc.
203
M10i Multiservice Edge Router Hardware Guide
13.
Turn on the DC power source so that voltage flows to the power supply.
14.
Press the switch on the power supply faceplate to the ON ( | ) position. When the power supply has powered on successfully, the green OUTPUT OK LED lights steadily.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on. After powering on a power supply, wait at least 60 seconds before turning it off.
If the router is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. If the Routing Engine finishes booting and you need to power off the router again, see
“Powering Off the M10i Router” on page 129
.
After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the output status LED on the power supply, the command display output, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.
Figure 75: Installing a DC Power Supply
204 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Figure 76: Connecting DC Power Cables to a DC Power Supply
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i DC Power Supply Description on page 65
•
M10i Router Power Requirements on page 82
•
Maintaining the M10i Power Supplies on page 224
•
Troubleshooting the M10i Power System on page 237
•
Removing an M10i DC Power Supply on page 201
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i DC Power Supply Description on page 65
•
M10i Router Power Requirements on page 82
•
Maintaining the M10i Power Supplies on page 224
•
Troubleshooting the M10i Power System on page 237
Copyright © 2019, Juniper Networks, Inc.
205
M10i Multiservice Edge Router Hardware Guide
Replacing an M10i DC Power Cable
A DC-powered router has up to four load-sharing DC power supplies. The router must have at least two DC power supplies, and any two DC power supplies can provide full power to the router. The power cords on a redundant power supply are hot-removable and hot-insertable, as described in
“M10i Field-Replaceable Units (FRUs)” on page 139
.
For M10i routers with only two DC power supplies, you must power off the router before replacing the DC power cables. See
“Powering Off the M10i Router” on page 129
.
1.
Removing a DC Power Cable on page 206
2.
Installing a DC Power Cable on page 207
Removing a DC Power Cable
To remove a DC power cable:
1.
For each power supply, press the power switch on the power supply faceplate to the
OFF ( O ) position.
NOTE: If you are power cycling the power supply rather than shutting it off for a time, wait at least 60 seconds after turning it off before turning it back on. If you need to power it off again, wait for at least 60 seconds after powering it on.
2.
Shut off the power flowing from both external power sources, so that the voltage across the leads of the DC power cables is 0 V. Ensure that there is no chance that the cable leads might become active during the procedure.
3.
Using a number 1 Phillips screwdriver, turn the screw on each field-wiring terminal counter-clockwise to loosen the terminal connector from around the cable lug.
4.
Remove the cables from the terminal connectors and from the hook located on the faceplate to the right of the field-wiring terminals.
5.
Verify that the removed cables are not touching or blocking access to any router components.
See Also •
M10i DC Power Supply Description on page 65
•
Troubleshooting the M10i Power System on page 237
•
Replacing an M10i DC Power Cable on page 206
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
206 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Installing a DC Power Cable
Connect DC power to the router by inserting DC power cables into the field-wiring terminals on the faceplate of each power supply. For information about the required cable type, see
“M10i DC Power Cable and Lug Specifications” on page 90 .
1.
Verify that there is no power flowing from the external power source, so that the voltage across the leads of the power cables is 0 V. Ensure that there is no chance that the cable leads might become active during the procedure.
2.
Verify that a licensed electrician has attached a listed DC power cable lug to the DC power cable.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Verify that the power switch on the power supply faceplate is in the OFF ( O ) position.
5.
Loop the DC power cables through the hook located on the faceplate to the right of the field-wiring terminals.
6.
Depending on the type of DC power cable lugs used, loosen or remove the screws on the field-wiring terminals.
7.
Insert the DC power cable lugs into the appropriate field-wiring terminals. Using a number 1 Phillips screwdriver, turn the screw on each field-wiring terminal clockwise to secure the DC power cable lug. Apply between 8 lb-in. (.9 Nm) and 9 lb-in. (1.02
Nm) of torque to each screw.
a.
Insert the positive (+) source cable into the return terminal, which is labeled RTN .
b.
Insert the negative (–) source cable into the input terminal, which is labeled –48V .
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the DC power cables that attach to the terminal studs on the power supply faceplate.
Copyright © 2019, Juniper Networks, Inc.
207
M10i Multiservice Edge Router Hardware Guide
NOTE: The DC power supplies in slots P/S 0 and P/S 1 must be powered by dedicated power feeds derived from feed A, and the DC power supplies in slots P/S 2 and P/S 3 must be powered by dedicated power feeds derived from feed B. This configuration provides the commonly deployed A/B feed redundancy for the system.
8.
Verify that the DC source power cabling is correct, that the DC cables are not touching or blocking access to router components, and that they do not drape where people could trip on them.
Figure 77: Connecting DC Power Cables
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i DC Power Supply Description on page 65
•
Troubleshooting the M10i Power System on page 237
Disconnecting Power on an AC-Powered M10i Router
To disconnect AC power from the router:
208 Copyright © 2019, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
1.
Power off the router. See
“Powering Off the M10i Router” on page 129
.
2.
Press the power switch on each power supply faceplate to the OFF ( O ) position.
3.
Unplug the AC power cord from each power supply.
NOTE: When multiple AC power supplies are installed in the chassis, all
AC power cords (one for each power supply) must be unplugged to disconnect power completely.
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
•
M10i AC Power Supply Description on page 64
•
M10i Router AC Power Supply Specifications on page 85
Disconnecting Power on an DC-Powered M10i Router
To disconnect DC power from the router:
1.
Power off the router (see
“Powering Off the M10i Router” on page 129
).
2.
For each power supply, press the power switch on the DC power supply faceplate to the OFF ( O ) position.
3.
Shut off the power flowing from both external power sources, so that the voltage across the leads of the DC power cables is 0 V. Ensure that there is no chance that the cable leads might become active during the procedure.
4.
Using a number 1 Phillips screwdriver, turn the screw on each field-wiring terminal counter-clockwise to loosen the terminal connector from around the cable.
5.
Remove the cables from the terminal connectors and from the hook located on the faceplate to the right of the field-wiring terminals.
6.
Verify that the removed cables are not touching or blocking access to any router components.
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
•
M10i DC Power Supply Description on page 65
Copyright © 2019, Juniper Networks, Inc.
209
M10i Multiservice Edge Router Hardware Guide
•
M10i Router DC Power Supply Specifications on page 89
210 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 27
Replacing Switch Fabric Components
•
Installing an M10i CFEB or CFEB-E on page 211
•
Replacing, Upgrading, or Downgrading an M10i CFEB or CFEB-E on page 212
Installing an M10i CFEB or CFEB-E
To install a CFEB or CFEB-E (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Verify that the ends of the ejector levers are pulled outward to a position nearly perpendicular to the faceplate of the CFEB or CFEB-E.
3.
Place one hand under the CFEB or CFEB-E to support it and grasp one of the ejector levers at the front with the other hand.
4.
Align the rear of the CFEB or CFEB-E with the guides inside the chassis and slide it in completely.
5.
Press the ejector lever at each end of the CFEB or CFEB-E inward.
6.
Tighten the thumbscrew on each ejector lever (shown in
) to seat the CFEB or CFEB-E firmly in the chassis.
7.
Press the online/offline button on the CFEB or CFEB-E faceplate and hold it down until the green LED labeled OUTPUT OK lights steadily.
You can also verify correct CFEB or CFEB-E functioning by issuing the show chassis cfeb commands described in
“Maintaining the M10i CFEB and CFEB-E” on page 225 .
Copyright © 2019, Juniper Networks, Inc.
211
M10i Multiservice Edge Router Hardware Guide
Figure 78: Installing a CFEB or CFEB-E
Related
Documentation
• Configuring CFEB Redundancy on the M10i Router
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description on page 67
•
Troubleshooting the M10i CFEB and CFEB-E on page 241
•
Replacing, Upgrading, or Downgrading an M10i CFEB or CFEB-E on page 212
•
Removing an M10i CFEB or CFEB-E on page 213
Replacing, Upgrading, or Downgrading an M10i CFEB or CFEB-E
One or two CFEBs or CFEB-Es can install into the uppermost slots in the rear of the chassis, as shown in
“M10i Chassis Description” on page 11
. Only one CFEB or CFEB-E is active at a time, with the optional second CFEB or CFEB-E in reset mode. CFEBs or
CFEB-Es are hot-pluggable when you replace a CFEB with a CFEB or a CFEB-E with a
CFEB-E, as described in
“M10i Field-Replaceable Units (FRUs)” on page 139
. Upgrading or downgrading a CFEB device requires a system reboot, as described in
Downgrading an M10i CFEB or CFEB-E” on page 215
. Removing the standby CFEB or
CFEB-E has no effect on router function. If the active CFEB or CFEB-E fails or is removed from the chassis, the effect depends on whether two CFEBs or CFEB-Es are installed:
• If there is only one CFEB or CFEB-E, forwarding halts until the CFEB or CFEB-E is replaced and functioning again.
• If there are two CFEBs or CFEB-Es, forwarding halts until the standby CFEB or CFEB-E boots and becomes active.
In both cases, all components in the Packet Forwarding Engine reset, and it takes approximately 1 minute for the new CFEB or CFEB-E to become active; synchronizing
212 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components router configuration information can take additional time, depending on the complexity of the configuration.
•
Removing an M10i CFEB or CFEB-E on page 213
•
Installing an M10i CFEB or CFEB-E on page 214
•
Upgrading or Downgrading an M10i CFEB or CFEB-E on page 215
Removing an M10i CFEB or CFEB-E
To remove a CFEB or CFEB-E (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
If you are removing the active SIB or CFEB-E, press and hold the online/offline button on the faceplate until the yellow LED labeled FAIL lights, which takes about 5 seconds.
(The effect of removing the active SIB or CFEB-E depends on whether a second SIB or CFEB-E is installed.
4.
Loosen the thumbscrew on each ejector lever, using a Phillips screwdriver if necessary.
5.
Pull the end of each ejector lever outward until it is nearly perpendicular to the CFEB or CFEB-E faceplate.
6.
Grasp the ejector levers and pull firmly to slide the CFEB or CFEB-E about halfway out of the chassis.
7.
Place one hand under the CFEB or CFEB-E to support it, slide it completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: When a CFEB or CFEB-E is out of the chassis, do not hold it by the ejector levers. They cannot support its weight.
Do not stack CFEBs or CFEB-Es on top of or under other components.
Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
Copyright © 2019, Juniper Networks, Inc.
213
M10i Multiservice Edge Router Hardware Guide
Figure 79: Removing a CFEB or CFEB-E
See Also •
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
• Configuring CFEB Redundancy on the M10i Router
•
M10i CFEB and CFEB-E LEDs on page 71
•
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description on page 67
•
Troubleshooting the M10i CFEB and CFEB-E on page 241
•
Replacing, Upgrading, or Downgrading an M10i CFEB or CFEB-E on page 212
•
Installing an M10i CFEB or CFEB-E on page 211
Installing an M10i CFEB or CFEB-E
To install a CFEB or CFEB-E (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Verify that the ends of the ejector levers are pulled outward to a position nearly perpendicular to the faceplate of the CFEB or CFEB-E.
3.
Place one hand under the CFEB or CFEB-E to support it and grasp one of the ejector levers at the front with the other hand.
4.
Align the rear of the CFEB or CFEB-E with the guides inside the chassis and slide it in completely.
5.
Press the ejector lever at each end of the CFEB or CFEB-E inward.
214 Copyright © 2019, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
6.
Tighten the thumbscrew on each ejector lever (shown in
) to seat the CFEB or CFEB-E firmly in the chassis.
7.
Press the online/offline button on the CFEB or CFEB-E faceplate and hold it down until the green LED labeled OUTPUT OK lights steadily.
You can also verify correct CFEB or CFEB-E functioning by issuing the show chassis cfeb commands described in
“Maintaining the M10i CFEB and CFEB-E” on page 225 .
Figure 80: Installing a CFEB or CFEB-E
See Also • Configuring CFEB Redundancy on the M10i Router
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description on page 67
•
Troubleshooting the M10i CFEB and CFEB-E on page 241
•
Replacing, Upgrading, or Downgrading an M10i CFEB or CFEB-E on page 212
•
Removing an M10i CFEB or CFEB-E on page 213
Upgrading or Downgrading an M10i CFEB or CFEB-E
To upgrade by replacing a CFEB with a CFEB-E or downgrade by replacing a CFEB-E with a CFEB requires a system reboot after swapping the CFEB devices.
To upgrade from a CFEB to a CFEB-E or to downgrade from a CFEB-E to a CFEB:
1.
Remove the CFEB or CFEB-E as described in
“Removing an M10i CFEB or CFEB-E” on page 213 .
2.
Install the upgrade CFEB-E or downgrade CFEB as described in
.
3.
Reboot the router:
• If the router has only one routing engine, issue the CLI command
Copyright © 2019, Juniper Networks, Inc.
215
M10i Multiservice Edge Router Hardware Guide user@host> request system reboot
• If the router has two routing engines (a primary routing engine and a backup routing engine), from the primary routing engine issue the following two CLI commands in immediate succession to force the router to reboot: user@host> request system reboot other-routing-engine user@host> request system reboot
After the reboot, the router recognizes the new CFEB or CFEB-E.
See Also • Configuring CFEB Redundancy on the M10i Router
•
M10i CFEB and CFEB-E LEDs on page 71
•
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description on page 67
•
Troubleshooting the M10i CFEB and CFEB-E on page 241
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
Removing an M10i CFEB or CFEB-E on page 213
•
Installing an M10i CFEB or CFEB-E on page 211
Related
Documentation
• Configuring CFEB Redundancy on the M10i Router
•
M10i CFEB and CFEB-E LEDs on page 71
•
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description on page 67
•
Troubleshooting the M10i CFEB and CFEB-E on page 241
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
216 Copyright © 2019, Juniper Networks, Inc.
PART 5
Maintaining the Chassis and Components
•
Routine Maintenance Procedures on page 219
•
Maintaining Components on page 221
Copyright © 2019, Juniper Networks, Inc.
217
M10i Multiservice Edge Router Hardware Guide
218 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 28
Routine Maintenance Procedures
•
Routine Maintenance Procedures for the M10i Router on page 219
Routine Maintenance Procedures for the M10i Router
Purpose For optimum router performance, perform preventive maintenance procedures.
Action • Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Verify that airflow is unobstructed around the router and into the air intake vents.
• Check the LEDs on the HCM and on hardware components. See
Chassis Manager (HCM) Description” on page 14 .
Related
Documentation
•
M10i Router Environmental Specifications on page 80
•
M10i Router Physical Specifications on page 76
•
Packing the M10i Router for Shipment on page 254
•
M10i Chassis Description on page 11
Copyright © 2019, Juniper Networks, Inc.
219
M10i Multiservice Edge Router Hardware Guide
220 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 29
Maintaining Components
•
Maintaining the M10i Cooling System on page 221
•
Maintaining the M10i Routing Engine on page 222
•
Maintaining the M10i PICs and PIC Cables on page 223
•
Maintaining the M10i Power Supplies on page 224
•
Maintaining the M10i CFEB and CFEB-E on page 225
Maintaining the M10i Cooling System
Purpose For optimum cooling, verify the condition of the fans.
Action The fan trays install into the rear of the chassis, as shown in
Figure 6 on page 12 . To check
the status of the fans in the fan trays, issue the show chassis environment command. The output includes an entry for each fan, as shown in this example: user@host> show chassis environment
Class Item Status Measurement
...
Fans Left Fan 1 OK Spinning at normal speed
Left Fan 2 OK Spinning at normal speed
Left Fan 3 OK Spinning at normal speed
Left Fan 4 OK Spinning at normal speed
Left Fan 5 OK Spinning at normal speed
Left Fan 6 OK Spinning at normal speed
Left Fan 7 OK Spinning at normal speed
Left Fan 8 OK Spinning at normal speed
...
For further description of the output from the command, see the CLI Explorer .
Related
Documentation
•
Installing an M10i Fan Tray on page 149
•
Troubleshooting the M10i Fan Tray on page 230
•
Replacing an M10i Fan Tray on page 150
Copyright © 2019, Juniper Networks, Inc.
221
M10i Multiservice Edge Router Hardware Guide
Maintaining the M10i Routing Engine
Purpose For optimum performance, verify the condition of the Routing Engine.
Action • Check the LEDs on the Routing Engine. The green LED labeled ONLINE lights steadily when it is functioning normally. For more information about the LEDs, see
Engine Description” on page 21 .
• Issue the CLI show chassis routing-engine command to check the status of the Routing
Engines: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 27 degrees C / 80 degrees F
CPU temperature 27 degrees C / 80 degrees F
DRAM 768 MB
Memory utilization 45 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 3 percent
Interrupt 0 percent
Idle 97 percent
Model RE-5.0
Serial ID 1000647001
Start time 2009-01-28 14:11:50 PST
Uptime 21 hours, 51 minutes, 16 seconds
Load averages: 1 minute 5 minute 15 minute
0.00 0.02 0.00
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
Temperature 26 degrees C / 78 degrees F
CPU temperature 27 degrees C / 80 degrees F
DRAM 1536 MB
Memory utilization 23 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 99 percent
Model RE-850
Serial ID 1000648260
Start time 2009-01-28 16:18:12 PST
Uptime 19 hours, 44 minutes, 51 seconds
For further description of the output from the command, see the CLI Explorer .
222 Copyright © 2019, Juniper Networks, Inc.
Chapter 29: Maintaining Components
Related
Documentation
•
Installing the M10i Routing Engine on page 153
•
M10i Routing Engine 400 LEDs on page 24
•
M10i Routing Engine 850 LEDs on page 26
•
M10i Routing Engine 1800 LEDs on page 28
•
M10i Routing Engine Architecture Overview on page 7
•
Replacing the M10i Routing Engine on page 158
Maintaining the M10i PICs and PIC Cables
Purpose For optimum performance, verify the condition of the PICs and PIC cables.
Action • Check the LEDs on PIC faceplates. The meaning of the LED states differs for various
PICs. For more information, see the M10i Multiservice Edge Router Interface Module
Reference . If the FPC that houses the PIC detects a PIC failure, the FPC generates an alarm message to be sent to the Routing Engine.
• Issue the CLI show chassis fpc pic-status command. The PIC slots in an FPC are numbered from 0 through 3 , top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online
PIC 0 4x OC-3 SONET, MM
PIC 1 1x CSTM1, SMIR
PIC 3 2x OC-3 ATM, MM
Slot 1 Online
PIC 0 1x OC-12 SONET, MM
PIC 1 1x OC-12 ATM, MM
PIC 2 2x OC-3 ATM, MM
PIC 3 2x OC-3 ATM, MM
For further description of the output from the command, see the CLI Explorer .
• Use the cable management system (shown in
) to support cables and prevent cables from dislodging or developing stress points. Place excess cable out of the way in the cable management system. Do not allow fastened loops of cable to dangle from the connector or cable management system, because this stresses the cable at the fastening point. Putting fasteners on the loops helps to maintain their shape.
• Keep the cable connections clean and free of dust and other particles, which can cause drops in the received power level. Always inspect cables and clean them if necessary before connecting an interface.
• Label both ends of PIC cables to identify them.
The following guidelines apply specifically to fiber-optic cable:
Copyright © 2019, Juniper Networks, Inc.
223
M10i Multiservice Edge Router Hardware Guide
• When you unplug a fiber-optic cable from a PIC, always place a rubber safety plug over the transceiver on the PIC faceplate and on the end of the cable.
• Anchor fiber-optic cable to avoid stress on the connectors. When attaching fiber to a
PIC, be sure to secure the fiber so it is not supporting its own weight as it hangs to the floor. Never let fiber-optic cable hang free from the connector.
• Avoid bending fiber-optic cable beyond its bend radius. An arc smaller than a few inches can damage the cable and cause problems that are difficult to diagnose.
• Frequent plugging and unplugging of fiber-optic cable into and out of optical instruments, such as ATM or SONET/SDH analyzers, can cause damage to the instruments that is expensive to repair. Instead, attach a short fiber extension to the optical equipment. Any wear and tear due to frequent plugging and unplugging is then absorbed by the short fiber extension, which is easy and inexpensive to replace.
• Keep fiber-optic cable connections clean. Small microdeposits of oil and dust in the canal of the transceiver or cable connector could cause loss of light, reducing signal power and possibly causing intermittent problems with the optical connection.
To clean the transceivers, use an appropriate fiber-cleaning device, such as RIFOCS
Fiber Optic Adaptor Cleaning Wands (part number 946). Follow the directions for the cleaning kit you use.
After you have cleaned the transceiver on the fiber-optic PIC, make sure that the connector tip of the fiber-optic cable is clean. Use only an approved alcohol-free fiber-optic cable cleaning kit, such as the Opptex Cletop-S
®
Fiber Cleaner. Follow the directions for the cleaning kit you use.
Related
Documentation
•
Connecting M10i PIC Cables on page 121
•
Installing an M10i PIC on page 173
•
Installing an M10i PIC Cable on page 175
•
Troubleshooting the M10i PICs on page 235
•
Replacing an M10i PIC on page 179
•
Replacing an M10i PIC Cable on page 184
Maintaining the M10i Power Supplies
Purpose For optimum router performance, verify the condition of the power supplies.
Action • Check that the green OUTPUT OK LED is lit on the faceplate of both power supplies.
For more information about the LED, see
“M10i Power Supply LEDs” on page 66 .
• Issue the following CLI command to check the status of the power supplies. As shown in the sample output, the value OK in the Status column indicates that the power supply is operating normally: user@host> show chassis environment
224 Copyright © 2019, Juniper Networks, Inc.
Chapter 29: Maintaining Components
Class Item Status Measurement
Power Power Supply A OK
Power Supply B OK
...
For further description of the output from the command, see the CLI Explorer .
• Check the red and yellow alarm LEDs on the HCM. Power supply failure or removal triggers an alarm that causes one or both of the LEDs to light. You can display the associated error messages by issuing the following CLI command: user@host> show chassis alarms
For a list of possible alarm messages, see
“M10i Hardware and Interface Alarm
.
• Verify that the power source has the proper current rating and that each power supply is connected to a separate power source.
• Verify that the cable or cord connecting the power supply to the external power source is securely in place and that there is no moisture accumulating near the router.
• Verify that the cable or cord from the power source to the router is not damaged. If the insulation is cracked or broken, replace the cable or cord immediately.
• Verify that the DC power cables or AC power cords do not touch or obstruct access to other router components, and that they do not drape where people could trip on them.
• Verify that the air flow in and out of cooling system components is not obstructed.
Related
Documentation
•
M10i Power System Description on page 63
•
M10i Router Power Requirements on page 82
•
Troubleshooting the M10i Power System on page 237
•
Troubleshooting the M10i Power System When LEDs on All Power Supplies Are Off on page 237
•
Troubleshooting the M10i Power System When the LED on One Power Supply Is Off on page 237
Maintaining the M10i CFEB and CFEB-E
Purpose For optimum cooling, verify the condition of the CFEB.
Action The Compact Forwarding Engine Board (CFEB) or Enhanced Compact Forwarding Engine
Board (CFEB-E) installs into the rear of the chassis, as shown in
. To maintain the CFEB or CFEB-E, perform the following procedures regularly:
• Check the system logging messages on the management console. The CFEB or CFEB-E notifies the Routing Engine of any errors it detects during normal operation.
Copyright © 2019, Juniper Networks, Inc.
225
M10i Multiservice Edge Router Hardware Guide
• Issue the CLI show chassis cfeb command to check the status of the CFEB (first output example) or the CFEB-E (second output example).
user@host> show chassis cfeb
CFEB status:
State Online
Intake Temperature 27 degrees C / 80 degrees F
Exhaust Temperature 33 degrees C / 91 degrees F
CPU utilization 3 percent
Interrupt utilization 0 percent
Heap utilization 8 percent
Buffer utilization 21 percent
Total CPU DRAM 128 MB
Internet Processor II Version 1, Foundry IBM, Part number 164
Start time: 2003-06-11 11:41:22 PDT
Uptime: 1 hour, 39 minutes, 31 seconds
CFEB—E status:
State Online
Intake Temperature 27 degrees C / 80 degrees F
Exhaust Temperature 33 degrees C / 91 degrees F
CPU utilization 3 percent
Interrupt utilization 0 percent
Heap utilization 8 percent
Buffer utilization 21 percent
Total CPU DRAM 128 MB
Internet Processor II Version 1, Foundry IBM, Part number 164
Start time: 2003-06-11 11:41:22 PDT
Uptime: 1 hour, 39 minutes, 31 seconds
For a description of the output from the command, see the CLI Explorer .
Related
Documentation
• Configuring CFEB Redundancy on the M10i Router
•
Installing an M10i CFEB or CFEB-E on page 211
•
M10i CFEB and CFEB-E LEDs on page 71
•
Troubleshooting the M10i CFEB and CFEB-E on page 241
226 Copyright © 2019, Juniper Networks, Inc.
PART 6
Troubleshooting Hardware
•
Troubleshooting Components on page 229
Copyright © 2019, Juniper Networks, Inc.
227
M10i Multiservice Edge Router Hardware Guide
228 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 30
Troubleshooting Components
•
M10i Hardware and Interface Alarm Messages on page 229
•
Troubleshooting the M10i HCM on page 230
•
Troubleshooting the M10i Fan Tray on page 230
•
Troubleshooting the M10i Routing Engine on page 233
•
Troubleshooting the M10i PICs on page 235
•
Troubleshooting the M10i Power System on page 237
•
Troubleshooting the M10i Power System When LEDs on All Power Supplies Are
•
Troubleshooting the M10i Power System When the LED on One Power Supply Is
•
Troubleshooting the M10i CFEB and CFEB-E on page 241
M10i Hardware and Interface Alarm Messages
When the Routing Engine detects an alarm condition, it lights the appropriate red or yellow alarm LED on the HCM. The HCM is located on the front of the chassis below the
FPC card cage, as shown in
The circular red alarm LED indicates a critical condition that can result in a system shutdown. The triangular yellow alarm indicates a less severe condition that requires monitoring or maintenance. Both alarms can occur simultaneously. For more information about the alarm LEDs, see
“M10i HCM Alarm LEDs” on page 16
.
• Chassis alarms—Indicate a problem with a chassis component such as the cooling system or power supplies.
• Interface alarms—Indicate a problem with a specific network interface, as described in
.
In both tables, the text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.
Copyright © 2019, Juniper Networks, Inc.
229
M10i Multiservice Edge Router Hardware Guide
Table 56: Chassis Alarm Messages
Chassis
Component
Alarm
Severity Alarm Condition
Hot swapping Red
Remedy
Too many hot-swap interrupts are occurring.
This message generally indicates that a hardware component that plugs into the router's midplane from the front is broken.
Contact technical support.
See
for more information.
Related
Documentation
•
Displaying M10i Router Components and Serial Numbers on page 247
•
M10i Router Physical Specifications on page 76
•
M10i Routing Engine 400 LEDs on page 24
•
M10i Routing Engine 850 LEDs on page 26
Troubleshooting the M10i HCM
Problem Description: The HCM is not functioning normally.
Solution A green LED labeled PWR reports the status of the HCM. When an HCM is functioning correctly, the green LED labeled OUTPUT OK is lit steadily. For more information, see
.
Related
Documentation
•
M10i High-Availability Chassis Manager (HCM) Description on page 14
•
Installing an M10i HCM on page 142
•
M10i HCM Alarm LEDs on page 16
•
Troubleshooting the M10i Fan Tray
Problem Description: The fans in the fan tray are not functioning normally.
230 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Troubleshooting Components
Solution To troubleshoot the cooling system:
1.
Check the alarm LEDs on the HCM:
• If the yellow or red alarm LED on the HCM is lit, issue the show chassis alarms CLI command to view a more detailed description of the alarm cause: user@host> show chassis alarms
For a list of messages that can appear in the output, see
• If all the LEDs on the HCM are not lit, it might indicate that power is not being provided to the router. See
“Troubleshooting the M10i Power System” on page 237 .
In some cases, the Routing Engine shuts down the router by turning off the power supplies if the temperature passes the acceptable maximum.
2.
Check the status of the cooling system by issuing the show chassis environment command. The output includes an entry for each fan and temperature for components, as shown in this example: user@host> show chassis environment
Class Item Status Measurement
Power Power Supply 0 OK
Power Supply 1 OK
Power Supply 2 Absent
Power Supply 3 Absent
Temp Intake OK 25 degrees C / 77 degrees F
FPC 0 OK 30 degrees C / 86 degrees F
FPC 1 OK 28 degrees C / 82 degrees F
Lower Power Supplies OK 28 degrees C / 82 degrees F
Upper Power Supplies OK 28 degrees C / 82 degrees F
Upper Power Supplies OK 28 degrees C / 82 degrees F
CFEB Intake OK 27 degrees C / 80 degrees F
CFEB Exhaust OK 35 degrees C / 95 degrees F
Routing Engine 0 OK 32 degrees C / 89 degrees F
Routing Engine 1 Absent
Fans Fan Tray 0 Absent
Fan Tray 1 Fan 1 OK Spinning at normal speed
Fan Tray 1 Fan 2 OK Spinning at normal speed
Fan Tray 1 Fan 3 OK Spinning at normal speed
Fan Tray 1 Fan 4 OK Spinning at normal speed
Fan Tray 1 Fan 5 OK Spinning at normal speed
Fan Tray 1 Fan 6 OK Spinning at normal speed
Fan Tray 1 Fan 7 OK Spinning at normal speed
Fan Tray 1 Fan 8 OK Spinning at normal speed
For further description of the output from the command, see the CLI Explorer .
3.
If you receive a temperature alarm:
• Check the temperature of each component by issuing the show chassis environment command. Temperature sensors on the components detect temperatures above the acceptable range. Verify that the temperature is OK for each component.
• Check the room temperature.
Copyright © 2019, Juniper Networks, Inc.
231
M10i Multiservice Edge Router Hardware Guide
• Check the airflow and clearance around the chassis. For the fan tray to function properly, the clearance around the chassis must be sufficient for unobstructed airflow. See
• Check if a faulty fan is causing the temperature to be elevated for one or more components.
4.
Check the fan tray:
• Check the status of the fans by issuing the show chassis environment command.
Verify that the status is OK and that the fans are Spinning at Normal Speed .
• If the fan tray fails, determine whether you can distinguish individual blades in a fan—this is not possible when the fans are rotating at normal speed.
5.
If you are unable to correct the problem, replace the fan tray with a spare. For instructions, see
“Replacing an M10i Fan Tray” on page 150 . If the LED lights correctly
on the spare, the original fan tray is faulty. Return it to Juniper Networks for replacement, as described in
“Returning a Hardware Component to Juniper Networks,
Table 57: Cooling System Alarm Messages
Chassis
Component
Alarm
Severity CLI Message
Fan Trays Red fan-name Failure
Temperature
Red
Yellow
Yellow
Too many fans missing or failing.
fan-name Removed
Temperature warm
Alarm Condition
A fan has failed.
Solution
Replace failed fan tray.
Both fan trays are absent from the chassis.
Install missing fan trays.
A fan is absent.
Install missing fan tray.
If the fans are running at full speed and one or more fans have failed, the chassis temperature has exceeded 55° C.
If the fans are running at full speed but no fans have failed, the chassis temperature has exceeded 65° C.
•
•
•
Check room temperature.
Check air flow.
Check fan tray.
232 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Troubleshooting Components
Table 57: Cooling System Alarm Messages (continued)
Chassis
Component
Alarm
Severity CLI Message
Red Temperature hot
Red Temperature sensor failure
Alarm Condition Solution
If a fan has failed, the chassis temperature has exceeded 65° C. If this condition persists for more than 4 minutes, the router shuts down.
The chassis temperature has exceeded 75° C. If this condition persists for more than 4 minutes, the router shuts down.
•
•
•
Check room temperature.
Check air flow.
Check fan tray.
The temperature sensor has failed.
Contact technical support.
See
for more information.
Related
Documentation
•
Installing an M10i Fan Tray on page 149
•
M10i Router Physical Specifications on page 76
•
Maintaining the M10i Cooling System on page 221
Troubleshooting the M10i Routing Engine
Problem Description: The Routing Engine is not functioning normally.
Solution A green LED labeled ONLINE reports the status of the Routing Engine. When a Routing
Engine is functioning correctly, the green LED labeled ONLINE is lit steadily. For more information, see
. To troubleshoot a Routing Engine:
1.
Check the alarm LEDs on the HCM.
2.
Issue the show chassis alarms CLI command to view a more detailed description of the alarm cause: user@host> show chassis alarms
For a list of messages that can appear in the output, see
.
3.
If an alarm indicates a problem with the CompactFlash card, reinstall the Junos OS from Removable Media. See the Software Installation and Upgrade Guide .
Copyright © 2019, Juniper Networks, Inc.
233
M10i Multiservice Edge Router Hardware Guide
4.
Verify that the Routing Engine is properly seated.
5.
If you are unable to correct the problem, replace the Routing Engine with a spare. For instructions, see
“Replacing the M10i Routing Engine” on page 158
. If the LED lights correctly on the spare, the original Routing Engine is faulty. Return it to Juniper
Networks, as described in
“Contacting Customer Support” on page 245 .
Table 58: Routing Engine Alarm Messages
Alarm
Severity CLI Message
Yellow
Yellow
Yellow
Yellow
Red
Red
Red
Host routing-engine-number hard-disk drive error
Alarm Condition Solution
Error in reading or writing hard disk.
Reinstall the Junos OS from Removable
Media.
Host routing-engine-number compact-flash drive error
ECC multibit parity error
Error in reading or writing the CompactFlash card.
Reinstall the Junos OS from Removable
Media.
A parity error occurred in the memory DIMMs
Replace the memory
DIMMs. See
Host routing-engine-number Boot from alternate media A CompactFlash card is installed, but the system booted from the hard disk.
No action is required if you configure your router to boot from the hard disk.
If not, reinstall the
Junos OS from
Removable Media.
Backup RE Active
Mixed Master and Backup RE types
Backup Routing Engine is active. Either a command was issued to switch to the backup Routing
Engine or the master
Routing Engine has failed.
No action is required if the backup Routing
Engine was intentionally made active.
If the master Routing
Engine failed, replace it.
One Routing Engine 400 and one Routing Engine
850 are installed in the same router.
Both Routing Engines must be the same model number.
Replace one of the
Routing Engines.
Host routing-engine-number compact-flash missing in boot list
CompactFlash card missing in boot list.
Replace the failed
Routing Engine.
234 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Troubleshooting Components
Table 58: Routing Engine Alarm Messages (continued)
Alarm
Severity CLI Message
Red
Red
Alarm Condition Solution
Host routing-engine-number hard-disk missing in boot list Hard disk missing in boot list.
Replace the failed
Routing Engine.
Loss of Communication with Backup RE Backup Routing Engine failed to boot.
Replace the failed
Routing Engine.
Related
Documentation
•
Installing the M10i Routing Engine on page 153
•
M10i Routing Engine 400 LEDs on page 24
•
M10i Routing Engine Architecture Overview on page 7
•
Maintaining the M10i Routing Engine on page 222
Troubleshooting the M10i PICs
Problem Description: The PICs are not functioning normally.
Solution To troubleshoot the PICs:
1.
Check the status of the LEDs located on the PIC faceplate. Many PICs have an LED labeled STATUS on their faceplate. Some PICs have additional LEDs, often one per port. For information about the LEDs on each PICs, see the M10i Multiservice Edge
Router Interface Module Reference .
2.
Issue the following CLI command to check the status of a PIC: user@host> show chassis fpc pic-status
Slot 0 Online
PIC 0 4x OC-3 SONET, MM
PIC 1 1x CSTM1, SMIR
PIC 3 2x OC-3 ATM, MM
Slot 1 Online
PIC 0 1x OC-12 SONET, MM
PIC 1 1x OC-12 ATM, MM
PIC 2 2x OC-3 ATM, MM
PIC 3 2x OC-3 ATM, MM
For further description of the output from the command, see the CLI Explorer .
The PIC slots are numbered from 0 through 3 , right to left
3.
If an LED is lit indicating a problem with the PIC, issue the show chassis alarms CLI command to view a more detailed description of the alarm cause:
Copyright © 2019, Juniper Networks, Inc.
235
M10i Multiservice Edge Router Hardware Guide user@host> show chassis alarms
For a list of messages that can appear in the output, see
4.
If you are unable to correct the problem, replace the PIC with a spare. For instructions, see
“Replacing an M10i PIC” on page 179 . If the LEDs light correctly on the spare, the
original PIC is faulty. Return it to Juniper Networks for replacement, as described in
“Contacting Customer Support” on page 245
.
Table 59: SONET/SDH Interface Alarm Messages
CLI Message interface-name sox / x / x - SONET bit error rate defect interface-name sox / x / x - SONET bit error rate fault interface-name sox / x / x - SONET line AIS interface-name sox / x / x - SONET line remote defect indicator interface-name sox / x / x - SONET loss of frame interface-name sox / x / x - SONET loss of light interface-name sox / x / x - SONET loss of pointer interface-name sox / x / x - SONET loss of signal interface-name sox / x / x - SONET path AIS interface-name sox / x / x - SONET path mismatch interface-name sox / x / x - SONET path remote defect indicator interface-name sox / x / x - SONET PLL lock interface-name sox / x / x - SONET remote error indicator interface-name sox / x / x - SONET severely errored frame interface-name sox / x / x - SONET unequipped
Related
Documentation
•
Installing an M10i PIC on page 173
•
•
M10i PICs Description on page 51
•
Maintaining the M10i PICs and PIC Cables on page 223
236 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Troubleshooting Components
Troubleshooting the M10i Power System
A green LED labeled OUTPUT OK reports the status of the power supply. When a power supply is functioning correctly, the green LED labeled OUTPUT OK is lit steadily. For more information, see
“M10i Power Supply LEDs” on page 66 .
If any other LED states apply, consult the following topics:
•
Troubleshooting the M10i Power System When LEDs on All Power Supplies Are
•
Troubleshooting the M10i Power System When the LED on One Power Supply Is
Troubleshooting the M10i Power System When LEDs on All Power Supplies Are Off
Problem Description: When no power is provided to the router, no LEDs are lit, including the power supply LEDs and the alarm LEDs on the HCM.
Solution To troubleshoot the power system when no LEDs are lit:
1.
Check if the router has been powered off or if a power failure has occurred.
2.
Check that the power is being provided from the facility power distribution.
3.
Check if the system temperature has exceeded the acceptable maximum. The Routing
Engine shuts down all power supplies is the temperature exceeds the maximum.
Excessive system temperature is almost always caused by excessive environmental temperature. Correct the environmental temperature before repowering the router.
See Also •
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
•
M10i Power System Description on page 63
•
M10i Power Supply LEDs on page 66
•
M10i Router Power Requirements on page 82
Troubleshooting the M10i Power System When the LED on One Power Supply Is Off
Problem Description: The LED on one power supply is off, but the LED on the other supplies indicate that they are functioning properly.
Copyright © 2019, Juniper Networks, Inc.
237
M10i Multiservice Edge Router Hardware Guide
Solution Perform the following diagnostic procedure:
1.
Check the red alarm LED on the HCM:
• If it is lit, issue the following CLI command for information about the cause of an alarm condition: user@host> show chassis alarms
For a list of messages that can appear in the output, see
.
A common cause of power supply shutdown is that the temperature of the power supply or another router component has exceed the maximum limit.
• If the red alarm LED is not lit, check that the power switch is in the ON position on the power supply faceplate.
2.
Replace the faulty power supply with a spare. For instructions, see
and
“Replacing an M10i DC Power Supply” on page 201 .
If the LED lights correctly on the spare, the original power supply is faulty. Return it to
Juniper Networks for replacement, as described in
“Returning a Hardware Component to Juniper Networks, Inc.” on page 253
.
3.
If the spare power supply also does not work, connect the router to a different power source. You might also try replacing the AC power cord (on an AC-powered router) or DC power cable (on a DC-powered router). For instructions, see
or
“Replacing an M10i DC Power Cable” on page 206
(you do not need to disconnect and reconnect the grounding cable on a DC-powered router).
4.
If you cannot determine the cause of the problem or need additional assistance, see
“Contacting Customer Support” on page 245
.
Table 60: Power System Alarm Messages
Alarm
Severity CLI Message
Yellow PEM pem-number removed
Red
Red
PEM pem-number Not OK
Too many PEMs missing
Alarm Condition Solution
A power supply has been removed.
Insert missing power supply.
A power supply has failed.
Replace failed power supply
Only one power supply is operating.
Insert or replace secondary power supply.
See Also •
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
238 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Troubleshooting Components
•
M10i Power System Description on page 63
•
M10i Power Supply LEDs on page 66
•
M10i Router Power Requirements on page 82
Related
Documentation
•
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
•
M10i Power System Description on page 63
•
M10i Power Supply LEDs on page 66
•
M10i Router Power Requirements on page 82
Troubleshooting the M10i Power System When LEDs on All Power Supplies Are Off
Problem Description: When no power is provided to the router, no LEDs are lit, including the power supply LEDs and the alarm LEDs on the HCM.
Solution To troubleshoot the power system when no LEDs are lit:
1.
Check if the router has been powered off or if a power failure has occurred.
2.
Check that the power is being provided from the facility power distribution.
3.
Check if the system temperature has exceeded the acceptable maximum. The Routing
Engine shuts down all power supplies is the temperature exceeds the maximum.
Excessive system temperature is almost always caused by excessive environmental temperature. Correct the environmental temperature before repowering the router.
Related
Documentation
•
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
•
M10i Power System Description on page 63
•
M10i Power Supply LEDs on page 66
•
M10i Router Power Requirements on page 82
Troubleshooting the M10i Power System When the LED on One Power Supply Is Off
Problem Description: The LED on one power supply is off, but the LED on the other supplies indicate that they are functioning properly.
Copyright © 2019, Juniper Networks, Inc.
239
M10i Multiservice Edge Router Hardware Guide
Solution Perform the following diagnostic procedure:
1.
Check the red alarm LED on the HCM:
• If it is lit, issue the following CLI command for information about the cause of an alarm condition: user@host> show chassis alarms
For a list of messages that can appear in the output, see
.
A common cause of power supply shutdown is that the temperature of the power supply or another router component has exceed the maximum limit.
• If the red alarm LED is not lit, check that the power switch is in the ON position on the power supply faceplate.
2.
Replace the faulty power supply with a spare. For instructions, see
and
“Replacing an M10i DC Power Supply” on page 201 .
If the LED lights correctly on the spare, the original power supply is faulty. Return it to
Juniper Networks for replacement, as described in
“Returning a Hardware Component to Juniper Networks, Inc.” on page 253
.
3.
If the spare power supply also does not work, connect the router to a different power source. You might also try replacing the AC power cord (on an AC-powered router) or DC power cable (on a DC-powered router). For instructions, see
or
“Replacing an M10i DC Power Cable” on page 206
(you do not need to disconnect and reconnect the grounding cable on a DC-powered router).
4.
If you cannot determine the cause of the problem or need additional assistance, see
“Contacting Customer Support” on page 245
.
Table 61: Power System Alarm Messages
Alarm
Severity CLI Message
Yellow PEM pem-number removed
Red
Red
PEM pem-number Not OK
Too many PEMs missing
Alarm Condition Solution
A power supply has been removed.
Insert missing power supply.
A power supply has failed.
Replace failed power supply
Only one power supply is operating.
Insert or replace secondary power supply.
Related
Documentation
•
M10i AC Power Supply Description on page 64
•
M10i DC Power Supply Description on page 65
240 Copyright © 2019, Juniper Networks, Inc.
Chapter 30: Troubleshooting Components
•
M10i Power System Description on page 63
•
M10i Power Supply LEDs on page 66
•
M10i Router Power Requirements on page 82
Troubleshooting the M10i CFEB and CFEB-E
Problem Description: The CFEB or CFEB-E is not functioning normally.
Solution When a CFEB or CFEB-E is functioning correctly, the green LED labeled OK is lit steadily.
For more information about the CFEB or CFEB-E LEDs, see
CFEB or CFEB-E fails, the forwarding and routing functions of the router halt immediately and do not resume until the CFEB or CFEB-E failure has been corrected.
To troubleshoot a CFEB or CFEB-E:
1.
Check the alarm LEDs on the HCM. If the yellow or red alarm LED on the HCM is lit, issue the show chassis alarms CLI command to view a more detailed description of the alarm cause: user@host> show chassis alarms
For a list of messages that can appear in the output, see
2.
Verify that the CFEB or CFEB-E is properly seated in the midplane. Use a Phillips screwdriver to ensure that the screws are securely tightened.
3.
If you are unable to correct the problem, replace the CFEB or CFEB-E with a spare.
For instructions, see
“Replacing, Upgrading, or Downgrading an M10i CFEB or CFEB-E” on page 212
. If the LED lights correctly on the spare, the original CFEB or CFEB-E is faulty. Return it to Juniper Networks, as described in
“Contacting Customer Support” on page 245 .
Table 62: CFEB or CFEB-E Alarm Messages
Alarm Severity Alarm Condition
Red
Red
Red
Both CFEBs/CFEB-Es have been removed or have failed.
Too many hard errors in
CFEB/CFEB-E memory.
Too many soft errors in
CFEB/CFEB-E memory.
Solution
Replace failed or missing
CFEB/CFEB-E.
Replace failed
CFEB/CFEB-E.
Replace failed
CFEB/CFEB-E.
Copyright © 2019, Juniper Networks, Inc.
241
M10i Multiservice Edge Router Hardware Guide
Table 62: CFEB or CFEB-E Alarm Messages (continued)
Alarm Severity Alarm Condition
Red
Solution
A CFEB/CFEB-E microcode download has failed.
Replace failed
CFEB/CFEB-E.
Related
Documentation
• Configuring CFEB Redundancy on the M10i Router
•
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description on page 67
•
Removing an M10i CFEB or CFEB-E on page 213
242 Copyright © 2019, Juniper Networks, Inc.
PART 7
Contacting Customer Support and
Returning the Chassis or Components
•
Contacting Customer Support on page 245
•
Locating Component Serial Numbers on page 247
•
Packing and Returning Components on page 253
Copyright © 2019, Juniper Networks, Inc.
243
M10i Multiservice Edge Router Hardware Guide
244 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 31
Contacting Customer Support
•
Contacting Customer Support on page 245
Contacting Customer Support
You can contact Juniper Networks Technical Assistance Center (JTAC) 24 hours a day,
7 days a week in one of the following ways:
• On the Web, using the Case Manager link at: https://www.juniper.net/support/
• By telephone:
From the US and Canada: 1-888-314-JTAC
From all other locations: 1-408-745-9500
If contacting JTAC by phone, enter your 12-digit case number followed by the # key if this is an existing case, or press the * key to be routed to the next available support engineer.
When requesting support from JTAC by telephone, be prepared to provide the following information:
• Your existing case number, if you have one
• Details of the failure or problem
• Type of activity being performed on the platform when the problem occurred
• Configuration data using one or more of the show commands
Copyright © 2019, Juniper Networks, Inc.
245
M10i Multiservice Edge Router Hardware Guide
246 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 32
Locating Component Serial Numbers
•
Displaying M10i Router Components and Serial Numbers on page 247
•
M10i HCM Serial Number ID Label on page 248
•
M10i Routing Engine Serial Number ID Label on page 249
•
M10i PIC Serial Number ID Label on page 250
•
M10i Power Supply Serial Number ID Label on page 251
•
M10i CFEB and CFEB-E Serial Number ID Label on page 251
Displaying M10i Router Components and Serial Numbers
Before contacting Juniper Networks, Inc. to request a Return Materials Authorization
(RMA), you must find the serial number on the router or component. To list all the router components and their serial numbers, enter the following command-line interface (CLI) command (the first example output is for a CFEB, the second example output is for a
CFEB-E): user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis 19152 M10i
Midplane REV 02 710-008920 CA0345
Power Supply 0 Rev 02 740-008985 PE10738 DC
Power Supply 1 Rev 02 740-008985 PE10745 DC
HCM slot 0 REV 02 710-008661 CA0374
HCM slot 1 REV 02 710-008661 CA0364
Routing Engine 0 REV 01 740-008846 1000413124 RE-5.0
Routing Engine 1 REV 01 740-008846 1000413128 RE-5.0
CFEB slot 0 REV 05 710-008599 CA0153 Internet Processor IIv1
CFEB slot 1 N/A N/A N/A backup
FPC 0 E-FPC
PIC 0 REV 03 750-005726 HK8844 1x OC-12 ATM-II, MM
PIC 1 REV 03 750-000611 AB8861 4x OC-3 SONET, MM
PIC 2 REV 02 750-002987 HB3841 1x OC-12 SONET, SMIR
PIC 3 REV 02 750-003037 HD4550 4x T1, RJ48
FPC 1 E-FPC
PIC 0 REV 04 750-003343 HA7349 4x T3 ATM
PIC 1 REV 04 750-003036 HD0124 4x E1, RJ48
PIC 2 REV 01 750-002982 HC7606 1x Tunnel
PIC 3 REV 05 750-003845 HF7007 1x 800M Crypto user@host> show chassis hardware
Copyright © 2019, Juniper Networks, Inc.
247
M10i Multiservice Edge Router Hardware Guide
Hardware inventory:
Item Version Part number Serial number Description
Chassis 39894 M10i
Midplane REV 04 710-008920 CN4635 M10i Midplane
Power Supply 0 Rev 02 740-008985 5425307 DC Power Supply
Power Supply 1 Rev 02 740-008985 5425481 DC Power Supply
Power Supply 2 Rev 02 740-008985 5425418 DC Power Supply
Power Supply 3 Rev 02 740-008985 5425448 DC Power Supply
HCM 0 REV 03 710-010580 CN6681 M10i HCM
HCM 1 REV 03 710-010580 CN6670 M10i HCM
Routing Engine 0 REV 01 740-011202 1000610328 RE-850
Routing Engine 1 REV 08 740-011202 9009006957 RE-850
CFEB 0 REV 01 750-023594 PR4674 Enhanced CFEB
CFEB 1 N/A N/A N/A Backup
FPC 0 E-FPC
PIC 0 REV 01 750-014628 DA5519 4x OC-3 1x OC-12 SFP
PIC 1 REV 07 750-010238 CS9646 1x G/E SFP, 1000 BASE
Xcvr 0 REV 01 740-011782 P8C1Q8N SFP-SX
PIC 2 REV 11 750-002992 CN8292 4x F/E, 100 BASE-TX
PIC 3 REV 12 750-002992 DC1621 4x F/E, 100 BASE-TX
FPC 1 E-FPC
PIC 0 REV 04 750-014627 WM4750 4x OC-3 1x OC-12 SFP
PIC 1 REV 01 750-014630 DA5535 1x OC-12-3 SFP
PIC 2 REV 01 750-014630 DA5530 1x OC-12-3 SFP
PIC 3 REV 10 750-007641 RE0082 1x G/E IQ, 1000 BASE
Xcvr 0 REV 01 740-011782 P9S0VPF SFP-SX
Fan Tray 1 Rear Right Fan Tray
Most components also have a small rectangular serial number ID label (see
) attached to the component body.
Figure 81: Serial Number ID Label
Related
Documentation
•
M10i CFEB and CFEB-E Serial Number ID Label on page 251
•
M10i HCM Serial Number ID Label on page 248
•
M10i PIC Serial Number ID Label on page 250
•
M10i Power Supply Serial Number ID Label on page 251
•
M10i Routing Engine Serial Number ID Label on page 249
•
Contacting Customer Support on page 245
M10i HCM Serial Number ID Label
The serial number ID label on an HCM is located near the front on the right side, as shown in
248 Copyright © 2019, Juniper Networks, Inc.
Figure 82: HCM Serial Number ID Label
Chapter 32: Locating Component Serial Numbers
Related
Documentation
•
M10i High-Availability Chassis Manager (HCM) Description on page 14
•
•
M10i HCM Alarm LEDs on page 16
•
Troubleshooting the M10i HCM on page 230
•
Replacing an M10i HCM on page 143
•
Contacting Customer Support on page 245
M10i Routing Engine Serial Number ID Label
The serial number ID label on a Routing Engine is located on the left side, near the back, as shown in
Figure 83 on page 250 . Some Routing Engines might have more than one serial
number. Contact your Juniper Networks support representative if you need assistance in determining which serial number to provide.
Copyright © 2019, Juniper Networks, Inc.
249
M10i Multiservice Edge Router Hardware Guide
Figure 83: Routing Engine Serial Number ID Label
Related
Documentation
•
M10i Routing Engine Description on page 21
•
Maintaining the M10i Routing Engine on page 222
•
Troubleshooting the M10i Routing Engine on page 233
•
Replacing the M10i Routing Engine on page 158
•
Contacting Customer Support on page 245
M10i PIC Serial Number ID Label
The serial number ID label for a PIC is located on the right side of the PIC, as shown in
Figure 84: PIC Serial Number ID Label
250
Related
Documentation
•
M10i PICs Description on page 51
•
Copyright © 2019, Juniper Networks, Inc.
Chapter 32: Locating Component Serial Numbers
•
Maintaining the M10i PICs and PIC Cables on page 223
•
Troubleshooting the M10i PICs on page 235
•
Replacing an M10i PIC on page 179
•
Contacting Customer Support on page 245
M10i Power Supply Serial Number ID Label
The serial number ID label on a power supply is located on the faceplate, as shown in
.
Figure 85: Power Supply Serial Number ID Label
Related
Documentation
•
M10i Power System Description on page 63Replacing an M10i DC Power Supply on page 201
•
Troubleshooting the M10i Power System When LEDs on All Power Supplies Are Off on page 237
•
Troubleshooting the M10i Power System When the LED on One Power Supply Is Off on page 237
•
Replacing an M10i AC Power Supply on page 195
•
Replacing an M10i DC Power Supply on page 201
•
Contacting Customer Support on page 245
M10i CFEB and CFEB-E Serial Number ID Label
The serial number ID label on a CFEB or CFEB-E is located on the right side of the top panel, as shown in
.
Copyright © 2019, Juniper Networks, Inc.
251
M10i Multiservice Edge Router Hardware Guide
Figure 86: CFEB or CBEF-E Serial Number ID Label
Related
Documentation
•
M10i Compact Forwarding Engine Board (CFEB) and Enhanced Compact Forwarding
Engine Board (CFEB-E) Description on page 67
•
M10i CFEB and CFEB-E LEDs on page 71
•
Maintaining the M10i CFEB and CFEB-E on page 225
•
Replacing, Upgrading, or Downgrading an M10i CFEB or CFEB-E on page 212
•
Contacting Customer Support on page 245
252 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 33
Packing and Returning Components
•
Returning a Hardware Component to Juniper Networks, Inc. on page 253
•
Tools and Parts Required to Remove Components from an M10i Router on page 254
•
Packing the M10i Router for Shipment on page 254
•
Guidelines for Packing M10i Components for Shipment on page 256
Returning a Hardware Component to Juniper Networks, Inc.
In the event of a hardware failure, please contact Juniper Networks, Inc. to obtain a Return
Material Authorization (RMA) number. This number is used to track the returned material at the factory and to return repaired or new components to the customer as needed.
NOTE: Do not return any component to Juniper Networks, Inc. unless you have first obtained an RMA number. Juniper Networks, Inc. reserves the right to refuse shipments that do not have an RMA. Refused shipments are returned to the customer by collect freight.
For more information about return and repair policies, see the customer support Web page at https://www.juniper.net/support/guidelines.html
.
For product problems or technical support issues, contact the Juniper Networks Technical
Assistance Center (JTAC) by using the Case Manager link at https://www.juniper.net/support/ or at 1-888-314-JTAC (within the United States) or
1-408-745-9500 (from outside the United States).
To return a defective hardware component:
1.
Determine the part number and serial number of the defective component.
2.
Obtain an RMA number from the Juniper Networks Technical Assistance Center (JTAC).
You can send e-mail or telephone as described above.
3.
Provide the following information in your e-mail message or during the telephone call:
• Part number and serial number of component
• Your name, organization name, telephone number, and fax number
Copyright © 2019, Juniper Networks, Inc.
253
M10i Multiservice Edge Router Hardware Guide
• Description of the failure
4.
The support representative validates your request and issues an RMA number for return of the component.
5.
Pack the component for shipment.
Tools and Parts Required to Remove Components from an M10i Router
To remove components from the router or the router from a rack, you need the following tools and parts:
• 2.5-mm flat-blade (–) screwdriver, for detaching alarm relay terminal block
• 7/16-in. (11 mm) nut driver
• Blank panels to cover empty slots
• Electrostatic bag or antistatic mat, for each component
• Electrostatic discharge (ESD) grounding wrist strap
• Flat-blade (–) screwdriver
• Mechanical lift, if available
• Phillips (+) screwdrivers, numbers 1 and 2
• Rubber safety cap for fiber-optic interfaces or cable
• Wire cutters
Related
Documentation
•
Contacting Customer Support on page 245
•
Returning a Hardware Component to Juniper Networks, Inc. on page 253
•
Packing the M10i Router for Shipment on page 254
•
Guidelines for Packing M10i Components for Shipment on page 256
Packing the M10i Router for Shipment
To pack the router for shipment:
1.
Retrieve the shipping crate and packing materials in which the router was originally shipped. If you do not have these materials, contact your Juniper Networks representative about approved packaging materials.
2.
Power off the router. See
“Powering Off the M10i Router” on page 129
.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
254 Copyright © 2019, Juniper Networks, Inc.
Chapter 33: Packing and Returning Components
4.
Disconnect power from the router. For instructions, see
AC-Powered M10i Router” on page 208
or
“Disconnecting Power on an DC-Powered
.
5.
Remove the cables that connect to all external devices. For instructions, see
“Replacing an M10i Ethernet Management Cable” on page 171 , “Replacing an M10i Console or
, and
“Removing an M10i PIC” on page 179
.
6.
Remove all Field Replaceable Units (FRUs) from the router.
7.
Remove the router from the rack:
• If you are using a mechanical lift, place the lift platform under the router, unscrew and remove the mounting screws from the rack, and move the router to the shipping crate.
• If you are not using a mechanical lift and the router weight is fully supported by a shelf or another router, unscrew and remove the mounting screws from the rack.
Three people can then lift the router and move it to the shipping crate.
• If you are not using a mechanical lift and the router weight is not fully supported by a shelf or another router, three people should grasp the router while a fourth person unscrews and removes the mounting screws from the rack. The three lifters can then move the router to the shipping crate.
8.
Place the router in the shipping crate or onto the pallet. If on a pallet, bolt the router to the pallet.
9.
Cover the router with an ESD bag and place the packing foam on top of and around the router.
10.
Replace the accessory box on top of the packing foam.
11.
Securely tape the box closed or place the crate cover over the router.
12.
Write the RMA number on the exterior of the box to ensure proper tracking.
Related
Documentation
•
Contacting Customer Support on page 245
•
Returning a Hardware Component to Juniper Networks, Inc. on page 253
•
Tools and Parts Required to Remove Components from an M10i Router on page 254
•
Guidelines for Packing M10i Components for Shipment on page 256
Copyright © 2019, Juniper Networks, Inc.
255
M10i Multiservice Edge Router Hardware Guide
Guidelines for Packing M10i Components for Shipment
To pack and ship individual components:
• When you return components, make sure they are adequately protected with packing materials and packed so that the pieces are prevented from moving around inside the carton.
• Use the original shipping materials if they are available.
• Place individual components in antistatic bags.
• Write the RMA number on the exterior of the box to ensure proper tracking.
CAUTION: Do not stack any of the hardware components.
Related
Documentation
•
Contacting Customer Support on page 245
•
Returning a Hardware Component to Juniper Networks, Inc. on page 253
•
Tools and Parts Required to Remove Components from an M10i Router on page 254
•
Packing the M10i Router for Shipment on page 254
256 Copyright © 2019, Juniper Networks, Inc.
PART 8
Safety
•
General Safety Guidelines and Warnings on page 259
•
Fire Safety Requirements on page 267
•
Installation Safety Guidelines and Warnings on page 269
•
Laser and LED Safety Guidelines and Warnings on page 277
•
Maintenance and Operational Safety Guidelines and Warnings on page 281
•
Electrical Safety Guidelines and Warnings on page 287
•
Agency Approvals and Compliance Statements on page 299
Copyright © 2019, Juniper Networks, Inc.
257
M10i Multiservice Edge Router Hardware Guide
258 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 34
General Safety Guidelines and Warnings
•
Definition of Safety Warning Levels on page 259
•
General Safety Guidelines for Juniper Networks Devices on page 261
•
General Safety Warnings for Juniper Networks Devices on page 262
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
Definition of Safety Warning Levels
The documentation uses the following levels of safety warnings:
NOTE: You might find this information helpful in a particular situation, or might otherwise overlook it.
CAUTION: You must observe the specified guidelines to avoid minor injury or discomfort to you, or severe damage to the hardware device.
WARNING: This symbol alerts you to the risk of personal injury from a laser.
WARNING: This symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen.
Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa,
Copyright © 2019, Juniper Networks, Inc.
259
M10i Multiservice Edge Router Hardware Guide
260 ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista.
Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels.
Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents.
Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer
Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der
Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen
Stromkreisen verbundenen Gefahren und der Standardpraktiken zur
Vermeidung von Unfällen bewußt.
Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti.
Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker.
Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes.
¡Atención!
Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes.
Varning!
Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador.
Related
Documentation
•
General Safety Warnings for Juniper Networks Devices on page 262
•
Installation Safety Warnings for Juniper Networks Devices on page 269
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 281
•
General Electrical Safety Warnings for Juniper Networks Devices on page 287
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 293
Copyright © 2019, Juniper Networks, Inc.
Chapter 34: General Safety Guidelines and Warnings
General Safety Guidelines for Juniper Networks Devices
The following guidelines help ensure your safety and protect the hardware equipment from damage. The list of guidelines might not address all potentially hazardous situations in your working environment, so be alert and exercise good judgment at all times.
• Perform only the procedures explicitly described in this documentation. Make sure that only authorized service personnel perform other system services.
• Keep the area around the chassis clear and free from dust before, during, and after installation.
• Keep tools away from areas where people could trip over them while walking.
• Do not wear loose clothing or jewelry, such as rings, bracelets, or chains, that could become caught in the chassis.
• Wear safety glasses if you are working under any conditions that could be hazardous to your eyes.
• Do not perform any actions that create a potential hazard to people or make the equipment unsafe.
• Never attempt to lift an object that is too heavy for one person to handle.
• Never install or manipulate wiring during electrical storms.
• Never install electrical jacks in wet locations unless the jacks are specifically designed for wet environments.
• Operate the hardware equipment only when the chassis is properly grounded.
• Do not open or remove chassis covers or sheet metal parts unless instructions are provided in this documentation. Such an action could cause severe electrical shock.
• Do not push or force any objects through any opening in the chassis frame. Such an action could result in electrical shock or fire.
• Avoid spilling liquid onto the chassis or onto any hardware component. Such an action could cause electrical shock or damage the hardware equipment.
• Avoid touching uninsulated electrical wires or terminals that have not been disconnected from their power source. Such an action could cause electrical shock.
• Some parts of the router might become hot. The following label provides the warning of the hot surfaces on the router:
Related
Documentation
•
General Safety Warnings for Juniper Networks Devices on page 262
Copyright © 2019, Juniper Networks, Inc.
261
M10i Multiservice Edge Router Hardware Guide
General Safety Warnings for Juniper Networks Devices
•
Qualified Personnel Warning on page 262
•
Restricted-Access Area Warning on page 262
Qualified Personnel Warning
WARNING: Only trained and qualified personnel should install or replace the hardware equipment.
Waarschuwing Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden.
Varoitus Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen.
Attention Tout installation ou remplacement de l'appareil doit être réalisé par du personnel qualifié et compétent.
Warnung Gerät nur von geschultem, qualifiziertem Personal installieren oder auswechseln lassen.
Avvertenza Solo personale addestrato e qualificato deve essere autorizzato ad installare o sostituire questo apparecchio.
Advarsel Kun kvalifisert personell med riktig opplæring bør montere eller bytte ut dette utstyret.
Aviso Este equipamento deverá ser instalado ou substituído apenas por pessoal devidamente treinado e qualificado.
¡Atención!
Estos equipos deben ser instalados y reemplazados exclusivamente por personal técnico adecuadamente preparado y capacitado.
Varning!
Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal.
Restricted-Access Area Warning
WARNING: The hardware equipment is intended for installation in restricted-access areas. A restricted-access area is an area to which access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and which is controlled by the authority responsible for the location.
Waarschuwing Dit toestel is bedoeld voor installatie op plaatsen met beperkte toegang. Een plaats met beperkte toegang is een plaats waar toegang slechts door servicepersoneel verkregen kan worden door middel van een speciaal
262 Copyright © 2019, Juniper Networks, Inc.
Chapter 34: General Safety Guidelines and Warnings
Copyright © 2019, Juniper Networks, Inc.
instrument, een slot en sleutel, of een ander veiligheidsmiddel, en welke beheerd wordt door de overheidsinstantie die verantwoordelijk is voor de locatie.
Varoitus Tämä laite on tarkoitettu asennettavaksi paikkaan, johon pääsy on rajoitettua. Paikka, johon pääsy on rajoitettua, tarkoittaa paikkaa, johon vain huoltohenkilöstö pääsee jonkin erikoistyökalun, lukkoon sopivan avaimen tai jonkin muun turvalaitteen avulla ja joka on paikasta vastuussa olevien toimivaltaisten henkilöiden valvoma.
Attention Cet appareil est à installer dans des zones d'accès réservé. Ces dernières sont des zones auxquelles seul le personnel de service peut accéder en utilisant un outil spécial, un mécanisme de verrouillage et une clé, ou tout autre moyen de sécurité. L'accès aux zones de sécurité est sous le contrôle de l'autorité responsable de l'emplacement.
Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem
Zutritt vorgesehen. Ein Bereich mit beschränktem Zutritt ist ein Bereich, zu dem nur Wartungspersonal mit einem Spezialwerkzeugs, Schloß und
Schlüssel oder anderer Sicherheitsvorkehrungen Zugang hat, und der von dem für die Anlage zuständigen Gremium kontrolliert wird.
Avvertenza Questa unità deve essere installata in un'area ad accesso limitato.
Un'area ad accesso limitato è un'area accessibile solo a personale di assistenza tramite un'attrezzo speciale, lucchetto, o altri dispositivi di sicurezza, ed è controllata dall'autorità responsabile della zona.
Advarsel Denne enheten er laget for installasjon i områder med begrenset adgang. Et område med begrenset adgang gir kun adgang til servicepersonale som bruker et spesielt verktøy, lås og nøkkel, eller en annen sikkerhetsanordning, og det kontrolleres av den autoriteten som er ansvarlig for området.
Aviso Esta unidade foi concebida para instalação em áreas de acesso restrito.
Uma área de acesso restrito é uma área à qual apenas tem acesso o pessoal de serviço autorizado, que possua uma ferramenta, chave e fechadura especial, ou qualquer outra forma de segurança. Esta área é controlada pela autoridade responsável pelo local.
¡Atención!
Esta unidad ha sido diseñada para instalarse en áreas de acceso restringido. Área de acceso restringido significa un área a la que solamente tiene acceso el personal de servicio mediante la utilización de una herramienta especial, cerradura con llave, o algún otro medio de seguridad, y que está bajo el control de la autoridad responsable del local.
Varning!
Denna enhet är avsedd för installation i områden med begränsat tillträde. Ett område med begränsat tillträde får endast tillträdas av servicepersonal med ett speciellt verktyg, lås och nyckel, eller annan säkerhetsanordning, och kontrolleras av den auktoritet som ansvarar för området.
263
M10i Multiservice Edge Router Hardware Guide
Related
Documentation
•
Installation Safety Warnings for Juniper Networks Devices on page 269
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 281
•
General Electrical Safety Warnings for Juniper Networks Devices on page 287
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 293
Preventing Electrostatic Discharge Damage to an M10i Router
Many router hardware components are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets. Observe the following guidelines to minimize the potential for electrostatic discharge (ESD) damage, which can cause intermittent or complete component failures:
• Always use an ESD wrist strap or ankle strap, and make sure that it is in direct contact with your skin.
CAUTION: For safety, periodically check the resistance value of the ESD strap. The measurement should be in the range of 1 through 10 Mohms.
• When handling any component that is removed from the chassis, make sure the equipment end of your ESD strap is attached to one of the ESD points on the chassis.
• Avoid contact between the component and your clothing. ESD voltages emitted from clothing can still damage components.
• When removing or installing a component, always place it component-side up on an antistatic surface, in an antistatic card rack, or in an electrostatic bag (see
Figure 87 on page 264 ) . If you are returning a component, place it in an electrostatic
bag before packing it.
Figure 87: Placing a Component into an Electrostatic Bag
264 Copyright © 2019, Juniper Networks, Inc.
Related
Documentation
•
M10i Chassis Description on page 11
Chapter 34: General Safety Guidelines and Warnings
Copyright © 2019, Juniper Networks, Inc.
265
M10i Multiservice Edge Router Hardware Guide
266 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 35
Fire Safety Requirements
•
Fire Safety Requirements for Juniper Networks Devices on page 267
Fire Safety Requirements for Juniper Networks Devices
•
General Fire Safety Requirements on page 267
•
•
Fire Suppression Equipment on page 267
General Fire Safety Requirements
In the event of a fire emergency involving network devices, the safety of people is the primary concern. Establish procedures for protecting people in a fire emergency, provide safety training, and properly provision fire-control equipment and fire extinguishers.
In addition, establish procedures to protect your equipment in a fire emergency. Juniper
Networks products must be installed in an environment suitable for electronic equipment.
We recommend that fire suppression equipment be available in the event of a fire in the vicinity of the equipment, and that you observe all local fire, safety, and electrical codes and ordinances when installing and operating your equipment.
Fire Suppression
In the event of an electrical hazard or an electrical fire, first turn off power to the equipment at the source. Then use a Type C fire extinguisher, which uses noncorrosive fire retardants, to extinguish the fire.
Fire Suppression Equipment
Type C fire extinguishers, which use noncorrosive fire retardants such as carbon dioxide
(CO
2
) and Halotron, are most effective for suppressing electrical fires. Type C fire extinguishers displace the oxygen from the point of combustion to eliminate the fire. For extinguishing fire on or around equipment that draws air from the environment for cooling, use this type of inert oxygen displacement extinguisher instead of an extinguisher that leave residues on equipment.
Do not use multipurpose Type ABC chemical fire extinguishers (dry chemical fire extinguishers) near Juniper Networks devices. The primary ingredient in these fire extinguishers is monoammonium phosphate, which is very sticky and difficult to clean.
Copyright © 2019, Juniper Networks, Inc.
267
M10i Multiservice Edge Router Hardware Guide
In addition, in minute amounts of moisture, monoammonium phosphate can become highly corrosive and corrodes most metals.
Any equipment in a room in which a chemical fire extinguisher has been discharged is subject to premature failure and unreliable operation. The equipment is considered to be irreparably damaged.
NOTE: To keep warranties effective, do not use a dry chemical fire extinguisher to control a fire at or near a Juniper Networks device. If a dry chemical fire extinguisher is used, the unit is no longer eligible for coverage under a service agreement.
We recommend that you dispose of any irreparably damaged equipment in an environmentally responsible manner.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 261
•
General Safety Warnings for Juniper Networks Devices on page 262
•
General Electrical Safety Warnings for Juniper Networks Devices on page 287
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 293
268 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 36
Installation Safety Guidelines and
Warnings
•
M10i Chassis Lifting Guidelines on page 269
•
Installation Safety Warnings for Juniper Networks Devices on page 269
M10i Chassis Lifting Guidelines
The weight of a fully configured chassis is about 79 lb (35.8 kg). Observe the following guidelines for lifting and moving the router:
• Before moving the router, read the guidelines in
“M10i Router Site Preparation Checklist” on page 75
to verify that the intended site meets the specified power, environmental, and clearance requirements.
• Do not attempt to lift a fully configured router by yourself. Using a mechanical lift to maneuver the router into a rack is recommended. If a lift cannot be used, a minimum of two people must lift the router.
• Before lifting or moving the router, disconnect all external cables.
• As when lifting any heavy object, lift most of the weight with your legs rather than your back. Keep your knees bent and your back relatively straight and avoid twisting your body as you lift. Balance the load evenly and be sure that your footing is solid.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 261
•
Installation Safety Warnings for Juniper Networks Devices on page 269
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 281
Installation Safety Warnings for Juniper Networks Devices
Observe the following warnings before and during hardware equipment installation:
•
Intrabuilding Ports Warning on page 270
•
Installation Instructions Warning on page 270
Copyright © 2019, Juniper Networks, Inc.
269
M10i Multiservice Edge Router Hardware Guide
•
Rack-Mounting Requirements and Warnings on page 271
•
Intrabuilding Ports Warning
WARNING: The intrabuilding ports of the equipment or subassembly are suitable for connection to intrabuilding or unexposed wiring or cabling only.
The intrabuilding ports of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the Outside Plant (OSP) or its wiring. These interfaces are designed for use as intrabuilding interfaces only (Type 2 or Type 4 ports as described in GR-1089) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
Installation Instructions Warning
WARNING: Read the installation instructions before you connect the hardware equipment to a power source.
Waarschuwing Raadpleeg de installatie-aanwijzingen voordat u het systeem met de voeding verbindt.
Varoitus Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen.
Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Warnung Lesen Sie die Installationsanweisungen, bevor Sie das System an die Stromquelle anschließen.
Avvertenza Consultare le istruzioni di installazione prima di collegare il sistema all'alimentatore.
Advarsel Les installasjonsinstruksjonene før systemet kobles til strømkilden.
Aviso Leia as instruções de instalação antes de ligar o sistema à sua fonte de energia.
¡Atención!
Ver las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Varning!
Läs installationsanvisningarna innan du kopplar systemet till dess strömförsörjningsenhet.
270 Copyright © 2019, Juniper Networks, Inc.
Chapter 36: Installation Safety Guidelines and Warnings
Rack-Mounting Requirements and Warnings
Ensure that the equipment rack into which the chassis is installed is evenly and securely supported, to avoid the hazardous condition that could result from uneven mechanical loading.
WARNING: To prevent bodily injury when mounting or servicing the chassis in a rack, take the following precautions to ensure that the system remains stable. The following directives help maintain your safety:
• The chassis must be installed into a rack that is secured to the building structure.
• The chassis should be mounted at the bottom of the rack if it is the only unit in the rack.
• When mounting the chassis in a partially-filled rack, load the rack from the bottom to the top, with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before mounting the chassis in the rack or servicing the hardware equipment.
Waarschuwing Om lichamelijk letsel te voorkomen wanneer u dit toestel in een rek monteert of het daar een servicebeurt geeft, moet u speciale voorzorgsmaatregelen nemen om ervoor te zorgen dat het toestel stabiel blijft. De onderstaande richtlijnen worden verstrekt om uw veiligheid te verzekeren:
• De router moet in een stellage worden geïnstalleerd die aan een bouwsel is verankerd.
• Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel het enige in het rek is.
• Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert, dient u het rek van onderen naar boven te laden met het zwaarste onderdeel onderaan in het rek.
• Als het rek voorzien is van stabiliseringshulpmiddelen, dient u de stabilisatoren te monteren voordat u het toestel in het rek monteert of het daar een servicebeurt geeft.
Varoitus Kun laite asetetaan telineeseen tai huolletaan sen ollessa telineessä, on noudatettava erityisiä varotoimia järjestelmän vakavuuden säilyttämiseksi, jotta vältytään loukkaantumiselta. Noudata seuraavia turvallisuusohjeita:
• Router on asennettava telineeseen, joka on kiinnitetty rakennukseen.
• Jos telineessä ei ole muita laitteita, aseta laite telineen alaosaan.
Copyright © 2019, Juniper Networks, Inc.
271
M10i Multiservice Edge Router Hardware Guide
272
• Jos laite asetetaan osaksi täytettyyn telineeseen, aloita kuormittaminen sen alaosasta kaikkein raskaimmalla esineellä ja siirry sitten sen yläosaan.
• Jos telinettä varten on vakaimet, asenna ne ennen laitteen asettamista telineeseen tai sen huoltamista siinä.
Attention Pour éviter toute blessure corporelle pendant les opérations de montage ou de réparation de cette unité en casier, il convient de prendre des précautions spéciales afin de maintenir la stabilité du système. Les directives ci-dessous sont destinées à assurer la protection du personnel:
• Le rack sur lequel est monté le router doit être fixé à la structure du bâtiment.
• Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas.
• Si cette unité est montée dans un casier partiellement rempli, charger le casier de bas en haut en plaçant l'élément le plus lourd dans le bas.
• Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs avant de monter ou de réparer l'unité en casier.
Warnung Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System stabil bleibt. Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen:
• Der router muß in einem Gestell installiert werden, das in der
Gebäudestruktur verankert ist.
• Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell angebracht werden.
• Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das
Gestell von unten nach oben zu laden, wobei das schwerste Bauteil unten im Gestell anzubringen ist.
• Wird das Gestell mit Stabilisierungszubehör geliefert, sind zuerst die
Stabilisatoren zu installieren, bevor Sie die Einheit im Gestell anbringen oder sie warten.
Avvertenza Per evitare infortuni fisici durante il montaggio o la manutenzione di questa unità in un supporto, occorre osservare speciali precauzioni per garantire che il sistema rimanga stabile. Le seguenti direttive vengono fornite per garantire la sicurezza personale:
• Il router deve essere installato in un telaio, il quale deve essere fissato alla struttura dell'edificio.
• Questa unità deve venire montata sul fondo del supporto, se si tratta dell'unica unità da montare nel supporto.
Copyright © 2019, Juniper Networks, Inc.
Copyright © 2019, Juniper Networks, Inc.
Chapter 36: Installation Safety Guidelines and Warnings
• Quando questa unità viene montata in un supporto parzialmente pieno, caricare il supporto dal basso all'alto, con il componente più pesante sistemato sul fondo del supporto.
• Se il supporto è dotato di dispositivi stabilizzanti, installare tali dispositivi prima di montare o di procedere alla manutenzione dell'unità nel supporto.
Advarsel Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt. Følgende retningslinjer er gitt for å verne om sikkerheten:
• Router må installeres i et stativ som er forankret til bygningsstrukturen.
• Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste enheten i kabinettet.
• Ved montering av denne enheten i et kabinett som er delvis fylt, skal kabinettet lastes fra bunnen og opp med den tyngste komponenten nederst i kabinettet.
• Hvis kabinettet er utstyrt med stabiliseringsutstyr, skal stabilisatorene installeres før montering eller utføring av reparasjonsarbeid på enheten i kabinettet.
Aviso Para se prevenir contra danos corporais ao montar ou reparar esta unidade numa estante, deverá tomar precauções especiais para se certificar de que o sistema possui um suporte estável. As seguintes directrizes ajudá-lo-ão a efectuar o seu trabalho com segurança:
• O router deverá ser instalado numa prateleira fixa à estrutura do edificio.
• Esta unidade deverá ser montada na parte inferior da estante, caso seja esta a única unidade a ser montada.
• Ao montar esta unidade numa estante parcialmente ocupada, coloque os itens mais pesados na parte inferior da estante, arrumando-os de baixo para cima.
• Se a estante possuir um dispositivo de estabilização, instale-o antes de montar ou reparar a unidade.
¡Atención!
Para evitar lesiones durante el montaje de este equipo sobre un bastidor, o posteriormente durante su mantenimiento, se debe poner mucho cuidado en que el sistema quede bien estable. Para garantizar su seguridad, proceda según las siguientes instrucciones:
• El router debe instalarse en un bastidor fijado a la estructura del edificio.
• Colocar el equipo en la parte inferior del bastidor, cuando sea la única unidad en el mismo.
273
M10i Multiservice Edge Router Hardware Guide
Ramp Warning
• Cuando este equipo se vaya a instalar en un bastidor parcialmente ocupado, comenzar la instalación desde la parte inferior hacia la superior colocando el equipo más pesado en la parte inferior.
• Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de montar o proceder al mantenimiento del equipo instalado en el bastidor.
Varning!
För att undvika kroppsskada när du installerar eller utför underhållsarbete på denna enhet på en ställning måste du vidta särskilda försiktighetsåtgärder för att försäkra dig om att systemet står stadigt. Följande riktlinjer ges för att trygga din säkerhet:
• Router måste installeras i en ställning som är förankrad i byggnadens struktur.
• Om denna enhet är den enda enheten på ställningen skall den installeras längst ned på ställningen.
• Om denna enhet installeras på en delvis fylld ställning skall ställningen fyllas nedifrån och upp, med de tyngsta enheterna längst ned på ställningen.
• Om ställningen är försedd med stabiliseringsdon skall dessa monteras fast innan enheten installeras eller underhålls på ställningen.
WARNING: When installing the hardware equipment, do not use a ramp inclined at more than 10 degrees.
Waarschuwing Gebruik een oprijplaat niet onder een hoek van meer dan 10 graden.
Varoitus Älä käytä sellaista kaltevaa pintaa, jonka kaltevuus ylittää 10 astetta.
Attention Ne pas utiliser une rampe dont l'inclinaison est supérieure à 10 degrés.
Warnung Keine Rampen mit einer Neigung von mehr als 10 Grad verwenden.
Avvertenza Non usare una rampa con pendenza superiore a 10 gradi.
Advarsel Bruk aldri en rampe som heller mer enn 10 grader.
Aviso Não utilize uma rampa com uma inclinação superior a 10 graus.
¡Atención!
No usar una rampa inclinada más de 10 grados
Varning!
Använd inte ramp med en lutning på mer än 10 grader.
274 Copyright © 2019, Juniper Networks, Inc.
Chapter 36: Installation Safety Guidelines and Warnings
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 261
•
General Safety Warnings for Juniper Networks Devices on page 262
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 281
Copyright © 2019, Juniper Networks, Inc.
275
M10i Multiservice Edge Router Hardware Guide
276 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 37
Laser and LED Safety Guidelines and
Warnings
•
General Laser Safety Guidelines for M10i Routers on page 277
•
M10i Laser and LED Safety Warnings on page 277
General Laser Safety Guidelines for M10i Routers
Physical Interface Cards (PICs) with single-mode optical interfaces are equipped with laser transmitters, which are considered a Class 1 Laser Product by the U.S. Food and
Drug Administration, and are evaluated as a Class 1 Laser Product per EN 60825–1 +A11
+A2 requirements.
When working around PICs, observe the following safety guidelines to prevent eye injury:
• Do not look into unterminated ports or at fibers that connect to unknown sources.
• Do not examine unterminated optical ports with optical instruments.
• Avoid direct exposure to the beam.
WARNING: Unterminated optical connectors can emit invisible laser radiation. The lens in the human eye focuses all the laser power on the retina, so focusing the eye directly on a laser source—even a low-power laser—could permanently damage the eye.
Related
Documentation
•
M10i Laser and LED Safety Warnings on page 277
M10i Laser and LED Safety Warnings
•
Class 1 Laser Product Warning on page 278
•
Class 1 LED Product Warning on page 278
•
Laser Beam Warning on page 278
•
Radiation from Open Port Apertures Warning on page 279
Copyright © 2019, Juniper Networks, Inc.
277
M10i Multiservice Edge Router Hardware Guide
Class 1 Laser Product Warning
WARNING: Class 1 laser product.
Waarschuwing Klasse-1 laser produkt.
Varoitus Luokan 1 lasertuote.
Attention Produit laser de classe I.
Warnung Laserprodukt der Klasse 1.
Avvertenza Prodotto laser di Classe 1.
Advarsel Laserprodukt av klasse 1.
Aviso Produto laser de classe 1.
¡Atención!
Producto láser Clase I.
Varning!
Laserprodukt av klass 1.
Class 1 LED Product Warning
WARNING: Class 1 LED product.
Waarschuwing Klasse 1 LED-product.
Varoitus Luokan 1 valodiodituote.
Attention Alarme de produit LED Class I.
Warnung Class 1 LED-Produktwarnung.
Avvertenza Avvertenza prodotto LED di Classe 1.
Advarsel LED-produkt i klasse 1.
Aviso Produto de classe 1 com LED.
¡Atención!
Aviso sobre producto LED de Clase 1.
Varning!
Lysdiodprodukt av klass 1.
Laser Beam Warning
WARNING: Do not stare into the laser beam or view it directly with optical instruments.
278 Copyright © 2019, Juniper Networks, Inc.
Chapter 37: Laser and LED Safety Guidelines and Warnings
Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten.
Varoitus Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla.
Attention Ne pas fixer le faisceau des yeux, ni l'observer directement à l'aide d'instruments optiques.
Warnung Nicht direkt in den Strahl blicken und ihn nicht direkt mit optischen
Geräten prüfen.
Avvertenza Non fissare il raggio con gli occhi né usare strumenti ottici per osservarlo direttamente.
Advarsel Stirr eller se ikke direkte p strlen med optiske instrumenter.
Aviso Não olhe fixamente para o raio, nem olhe para ele directamente com instrumentos ópticos.
¡Atención!
No mirar fijamente el haz ni observarlo directamente con instrumentos ópticos.
Varning!
Rikta inte blicken in mot strålen och titta inte direkt på den genom optiska instrument.
Radiation from Open Port Apertures Warning
WARNING: Because invisible radiation may be emitted from the aperture of the port when no fiber cable is connected, avoid exposure to radiation and do not stare into open apertures.
Waarschuwing Aangezien onzichtbare straling vanuit de opening van de poort kan komen als er geen fiberkabel aangesloten is, dient blootstelling aan straling en het kijken in open openingen vermeden te worden.
Varoitus Koska portin aukosta voi emittoitua näkymätöntä säteilyä, kun kuitukaapelia ei ole kytkettynä, vältä säteilylle altistumista äläkä katso avoimiin aukkoihin.
Attention Des radiations invisibles à l'il nu pouvant traverser l'ouverture du port lorsqu'aucun câble en fibre optique n'y est connecté, il est recommandé de ne pas regarder fixement l'intérieur de ces ouvertures.
Warnung Aus der Port-Öffnung können unsichtbare Strahlen emittieren, wenn kein Glasfaserkabel angeschlossen ist. Vermeiden Sie es, sich den
Strahlungen auszusetzen, und starren Sie nicht in die Öffnungen!
Copyright © 2019, Juniper Networks, Inc.
279
M10i Multiservice Edge Router Hardware Guide
Avvertenza Quando i cavi in fibra non sono inseriti, radiazioni invisibili possono essere emesse attraverso l'apertura della porta. Evitate di esporvi alle radiazioni e non guardate direttamente nelle aperture.
Advarsel Unngå utsettelse for stråling, og stirr ikke inn i åpninger som er åpne, fordi usynlig stråling kan emiteres fra portens åpning når det ikke er tilkoblet en fiberkabel.
Aviso Dada a possibilidade de emissão de radiação invisível através do orifício da via de acesso, quando esta não tiver nenhum cabo de fibra conectado, deverá evitar a exposição à radiação e não deverá olhar fixamente para orifícios que se encontrarem a descoberto.
¡Atención!
Debido a que la apertura del puerto puede emitir radiación invisible cuando no existe un cable de fibra conectado, evite mirar directamente a las aperturas para no exponerse a la radiación.
Varning!
Osynlig strålning kan avges från en portöppning utan ansluten fiberkabel och du bör därför undvika att bli utsatt för strålning genom att inte stirra in i oskyddade öppningar.
Related
Documentation
•
General Laser Safety Guidelines for M10i Routers on page 277
280 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 38
Maintenance and Operational Safety
Guidelines and Warnings
•
Maintenance and Operational Safety Warnings for Juniper Networks Devices on page 281
Maintenance and Operational Safety Warnings for Juniper Networks Devices
As you maintain the hardware equipment, observe the following warnings:
•
Battery Handling Warning on page 281
•
Jewelry Removal Warning on page 282
•
Lightning Activity Warning on page 283
•
Operating Temperature Warning on page 284
•
Product Disposal Warning on page 285
Battery Handling Warning
WARNING: Replacing the battery incorrectly might result in an explosion.
Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Waarschuwing Er is ontploffingsgevaar als de batterij verkeerd vervangen wordt. Vervang de batterij slechts met hetzelfde of een equivalent type dat door de fabrikant aanbevolen is. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften weggeworpen te worden.
Varoitus Räjähdyksen vaara, jos akku on vaihdettu väärään akkuun. Käytä vaihtamiseen ainoastaan saman- tai vastaavantyyppistä akkua, joka on valmistajan suosittelema. Hävitä käytetyt akut valmistajan ohjeiden mukaan.
Attention Danger d'explosion si la pile n'est pas remplacée correctement.
Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant.
Copyright © 2019, Juniper Networks, Inc.
281
M10i Multiservice Edge Router Hardware Guide
Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr.
Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den
Anweisungen des Herstellers.
Avvertenza Pericolo di esplosione se la batteria non è installata correttamente. Sostituire solo con una di tipo uguale o equivalente, consigliata dal produttore. Eliminare le batterie usate secondo le istruzioni del produttore.
Advarsel Det kan være fare for eksplosjon hvis batteriet skiftes på feil måte.
Skift kun med samme eller tilsvarende type som er anbefalt av produsenten.
Kasser brukte batterier i henhold til produsentens instruksjoner.
Aviso Existe perigo de explosão se a bateria for substituída incorrectamente.
Substitua a bateria por uma bateria igual ou de um tipo equivalente recomendado pelo fabricante. Destrua as baterias usadas conforme as instruções do fabricante.
¡Atención!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante. Desechar las baterías gastadas según las instrucciones del fabricante.
Varning!
Explosionsfara vid felaktigt batteribyte. Ersätt endast batteriet med samma batterityp som rekommenderas av tillverkaren eller motsvarande.
Följ tillverkarens anvisningar vid kassering av använda batterier.
Jewelry Removal Warning
WARNING: Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal objects heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals.
Waarschuwing Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen. Metalen voorwerpen worden warm wanneer ze met stroom en aarde zijn verbonden, en kunnen ernstige brandwonden veroorzaken of het metalen voorwerp aan de aansluitklemmen lassen.
Varoitus Ennen kuin työskentelet voimavirtajohtoihin kytkettyjen laitteiden parissa, ota pois kaikki korut (sormukset, kaulakorut ja kellot mukaan lukien).
Metalliesineet kuumenevat, kun ne ovat yhteydessä sähkövirran ja maan kanssa, ja ne voivat aiheuttaa vakavia palovammoja tai hitsata metalliesineet kiinni liitäntänapoihin.
Attention Avant d'accéder à cet équipement connecté aux lignes électriques,
ôter tout bijou (anneaux, colliers et montres compris). Lorsqu'ils sont branchés
282 Copyright © 2019, Juniper Networks, Inc.
Chapter 38: Maintenance and Operational Safety Guidelines and Warnings
à l'alimentation et reliés à la terre, les objets métalliques chauffent, ce qui peut provoquer des blessures graves ou souder l'objet métallique aux bornes.
Warnung Vor der Arbeit an Geräten, die an das Netz angeschlossen sind, jeglichen Schmuck (einschließlich Ringe, Ketten und Uhren) abnehmen.
Metallgegenstände erhitzen sich, wenn sie an das Netz und die Erde angeschlossen werden, und können schwere Verbrennungen verursachen oder an die Anschlußklemmen angeschweißt werden.
Avvertenza Prima di intervenire su apparecchiature collegate alle linee di alimentazione, togliersi qualsiasi monile (inclusi anelli, collane, braccialetti ed orologi). Gli oggetti metallici si riscaldano quando sono collegati tra punti di alimentazione e massa: possono causare ustioni gravi oppure il metallo può saldarsi ai terminali.
Advarsel Fjern alle smykker (inkludert ringer, halskjeder og klokker) før du skal arbeide på utstyr som er koblet til kraftledninger. Metallgjenstander som er koblet til kraftledninger og jord blir svært varme og kan forårsake alvorlige brannskader eller smelte fast til polene.
Aviso Antes de trabalhar em equipamento que esteja ligado a linhas de corrente, retire todas as jóias que estiver a usar (incluindo anéis, fios e relógios). Os objectos metálicos aquecerão em contacto com a corrente e em contacto com a ligação à terra, podendo causar queimaduras graves ou ficarem soldados aos terminais.
¡Atención!
Antes de operar sobre equipos conectados a líneas de alimentación, quitarse las joyas (incluidos anillos, collares y relojes). Los objetos de metal se calientan cuando se conectan a la alimentación y a tierra, lo que puede ocasionar quemaduras graves o que los objetos metálicos queden soldados a los bornes.
Varning!
Tag av alla smycken (inklusive ringar, halsband och armbandsur) innan du arbetar på utrustning som är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och kan förorsaka allvarliga brännskador; metallobjekt kan också sammansvetsas med kontakterna.
Lightning Activity Warning
WARNING: Do not work on the system or connect or disconnect cables during periods of lightning activity.
Waarschuwing Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen.
Varoitus Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla.
Copyright © 2019, Juniper Networks, Inc.
283
M10i Multiservice Edge Router Hardware Guide
Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
Warnung Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw. trennen Sie keine ab, wenn es gewittert.
Avvertenza Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini.
Advarsel Utfør aldri arbeid på systemet, eller koble kabler til eller fra systemet når det tordner eller lyner.
Aviso Não trabalhe no sistema ou ligue e desligue cabos durante períodos de mau tempo (trovoada).
¡Atención!
No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas eléctricas en la atmósfera.
Varning!
Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar.
Operating Temperature Warning
WARNING: To prevent the hardware equipment from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 104° F (40° C). To prevent airflow restriction, allow at least
6 inches (15.2 cm) of clearance around the ventilation openings.
Waarschuwing Om te voorkomen dat welke router van de router dan ook oververhit raakt, dient u deze niet te bedienen op een plaats waar de maximale aanbevolen omgevingstemperatuur van 40° C wordt overschreden. Om te voorkomen dat de luchtstroom wordt beperkt, dient er minstens 15,2 cm speling rond de ventilatie-openingen te zijn.
Varoitus Ettei router-sarjan reititin ylikuumentuisi, sitä ei saa käyttää tilassa, jonka lämpötila ylittää korkeimman suositellun ympäristölämpötilan 40° C.
Ettei ilmanvaihto estyisi, tuuletusaukkojen ympärille on jätettävä ainakin
15,2 cm tilaa.
Attention Pour éviter toute surchauffe des routeurs de la gamme router, ne l'utilisez pas dans une zone où la température ambiante est supérieure à
40° C. Pour permettre un flot d'air constant, dégagez un espace d'au moins
15,2 cm autour des ouvertures de ventilations.
Warnung Um einen router der router vor Überhitzung zu schützen, darf dieser nicht in einer Gegend betrieben werden, in der die Umgebungstemperatur das empfohlene Maximum von 40° C überschreitet. Um Lüftungsverschluß zu verhindern, achten Sie darauf, daß mindestens 15,2 cm lichter Raum um die Lüftungsöffnungen herum frei bleibt.
284 Copyright © 2019, Juniper Networks, Inc.
Chapter 38: Maintenance and Operational Safety Guidelines and Warnings
Avvertenza Per evitare il surriscaldamento dei router, non adoperateli in un locale che ecceda la temperatura ambientale massima di 40° C. Per evitare che la circolazione dell'aria sia impedita, lasciate uno spazio di almeno 15.2 cm di fronte alle aperture delle ventole.
Advarsel Unngå overoppheting av eventuelle rutere i router Disse skal ikke brukes på steder der den anbefalte maksimale omgivelsestemperaturen overstiger 40° C (104° F). Sørg for at klaringen rundt lufteåpningene er minst
15,2 cm (6 tommer) for å forhindre nedsatt luftsirkulasjon.
Aviso Para evitar o sobreaquecimento do encaminhador router, não utilize este equipamento numa área que exceda a temperatura máxima recomendada de 40° C. Para evitar a restrição à circulação de ar, deixe pelo menos um espaço de 15,2 cm à volta das aberturas de ventilação.
¡Atención!
Para impedir que un encaminador de la serie router se recaliente, no lo haga funcionar en un área en la que se supere la temperatura ambiente máxima recomendada de 40° C. Para impedir la restricción de la entrada de aire, deje un espacio mínimo de 15,2 cm alrededor de las aperturas para ventilación.
Varning!
Förhindra att en router överhettas genom att inte använda den i ett område där den maximalt rekommenderade omgivningstemperaturen på
40° C överskrids. Förhindra att luftcirkulationen inskränks genom att se till att det finns fritt utrymme på minst 15,2 cm omkring ventilationsöppningarna.
Product Disposal Warning
WARNING: Disposal of this product must be handled according to all national laws and regulations.
Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt.
Varoitus Tämän tuotteen lopullisesta hävittämisestä tulee huolehtia kaikkia valtakunnallisia lakeja ja säännöksiä noudattaen.
Attention La mise au rebut définitive de ce produit doit être effectuée conformément à toutes les lois et réglementations en vigueur.
Warnung Dieses Produkt muß den geltenden Gesetzen und Vorschriften entsprechend entsorgt werden.
Avvertenza L'eliminazione finale di questo prodotto deve essere eseguita osservando le normative italiane vigenti in materia
Advarsel Endelig disponering av dette produktet må skje i henhold til nasjonale lover og forskrifter.
Copyright © 2019, Juniper Networks, Inc.
285
M10i Multiservice Edge Router Hardware Guide
Aviso A descartagem final deste produto deverá ser efectuada de acordo com os regulamentos e a legislação nacional.
¡Atención!
El desecho final de este producto debe realizarse según todas las leyes y regulaciones nacionales
Varning!
Slutlig kassering av denna produkt bör skötas i enlighet med landets alla lagar och föreskrifter.
Related
Documentation
•
General Safety Guidelines for Juniper Networks Devices on page 261
•
General Safety Warnings for Juniper Networks Devices on page 262
286 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 39
Electrical Safety Guidelines and Warnings
•
General Electrical Safety Warnings for Juniper Networks Devices on page 287
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
•
M10i AC Power Electrical Safety Guidelines on page 291
•
Japanese AC Power Cord Warning for M Series and MX Series Routers on page 292
•
M10i DC Power Electrical Safety Guidelines on page 292
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 293
General Electrical Safety Warnings for Juniper Networks Devices
•
Grounded Equipment Warning on page 287
•
Grounding Requirements and Warning on page 288
•
Midplane Energy Hazard Warning on page 289
•
Multiple Power Supplies Disconnection Warning on page 289
•
Power Disconnection Warning on page 290
Grounded Equipment Warning
WARNING: The network device is intended to be grounded. Ensure that the network device is connected to earth ground during normal use.
Waarschuwing Deze apparatuur hoort geaard te worden Zorg dat de host-computer tijdens normaal gebruik met aarde is verbonden.
Varoitus Tämä laitteisto on tarkoitettu maadoitettavaksi. Varmista, että isäntälaite on yhdistetty maahan normaalikäytön aikana.
Attention Cet équipement doit être relié à la terre. S'assurer que l'appareil hôte est relié à la terre lors de l'utilisation normale.
Warnung Dieses Gerät muß geerdet werden. Stellen Sie sicher, daß das
Host-Gerät während des normalen Betriebs an Erde gelegt ist.
Copyright © 2019, Juniper Networks, Inc.
287
M10i Multiservice Edge Router Hardware Guide
Avvertenza Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia collegato alla massa di terra durante il normale utilizzo.
Advarsel Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk.
Aviso Este equipamento deverá estar ligado à terra. Certifique-se que o host se encontra ligado à terra durante a sua utilização normal.
¡Atención!
Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté conectado a tierra durante el uso normal.
Varning!
Denna utrustning är avsedd att jordas. Se till att värdenheten är jordad vid normal användning.
Grounding Requirements and Warning
An insulated grounding conductor that is identical in size to the grounded and ungrounded branch circuit supply conductors, but is identifiable by green and yellow stripes, is installed as part of the branch circuit that supplies the unit. The grounding conductor is a separately derived system at the supply transformer or motor generator set.
WARNING: When installing the network device, you must always make the ground connection first and disconnect it last.
Waarschuwing Bij de installatie van het toestel moet de aardverbinding altijd het eerste worden gemaakt en het laatste worden losgemaakt.
Varoitus Laitetta asennettaessa on maahan yhdistäminen aina tehtävä ensiksi ja maadoituksen irti kytkeminen viimeiseksi.
Attention Lors de l'installation de l'appareil, la mise à la terre doit toujours
être connectée en premier et déconnectée en dernier.
Warnung Der Erdanschluß muß bei der Installation der Einheit immer zuerst hergestellt und zuletzt abgetrennt werden.
Avvertenza In fase di installazione dell'unità, eseguire sempre per primo il collegamento a massa e disconnetterlo per ultimo.
Advarsel Når enheten installeres, må jordledningen alltid tilkobles først og frakobles sist.
Aviso Ao instalar a unidade, a ligação à terra deverá ser sempre a primeira a ser ligada, e a última a ser desligada.
¡Atención!
Al instalar el equipo, conectar la tierra la primera y desconectarla la última.
288 Copyright © 2019, Juniper Networks, Inc.
Chapter 39: Electrical Safety Guidelines and Warnings
Varning!
Vid installation av enheten måste jordledningen alltid anslutas först och kopplas bort sist.
Midplane Energy Hazard Warning
WARNING: High levels of electrical energy are distributed across the midplane.
Be careful not to contact the midplane connectors, or any component connected to the midplane, with any metallic object while servicing components.
Multiple Power Supplies Disconnection Warning
WARNING: The network device has more than one power supply connection.
All connections must be removed completely to remove power from the unit completely.
Waarschuwing Deze eenheid heeft meer dan één stroomtoevoerverbinding; alle verbindingen moeten volledig worden verwijderd om de stroom van deze eenheid volledig te verwijderen.
Varoitus Tässä laitteessa on useampia virtalähdekytkentöjä. Kaikki kytkennät on irrotettava kokonaan, jotta virta poistettaisiin täysin laitteesta.
Attention Cette unité est équipée de plusieurs raccordements d'alimentation.
Pour supprimer tout courant électrique de l'unité, tous les cordons d'alimentation doivent être débranchés.
Warnung Diese Einheit verfügt über mehr als einen Stromanschluß; um Strom gänzlich von der Einheit fernzuhalten, müssen alle Stromzufuhren abgetrennt sein.
Avvertenza Questa unità ha più di una connessione per alimentatore elettrico; tutte le connessioni devono essere completamente rimosse per togliere l'elettricità dall'unità.
Advarsel Denne enheten har mer enn én strømtilkobling. Alle tilkoblinger må kobles helt fra for å eliminere strøm fra enheten.
Aviso Este dispositivo possui mais do que uma conexão de fonte de alimentação de energia; para poder remover a fonte de alimentação de energia, deverão ser desconectadas todas as conexões existentes.
¡Atención!
Esta unidad tiene más de una conexión de suministros de alimentación; para eliminar la alimentación por completo, deben desconectarse completamente todas las conexiones.
Copyright © 2019, Juniper Networks, Inc.
289
M10i Multiservice Edge Router Hardware Guide
Varning!
Denna enhet har mer än en strömförsörjningsanslutning; alla anslutningar måste vara helt avlägsnade innan strömtillförseln till enheten
är fullständigt bruten.
Power Disconnection Warning
WARNING: Before working on the chassis or near power supplies, switch off the power at the DC circuit breaker.
Waarschuwing Voordat u aan een frame of in de nabijheid van voedingen werkt, dient u bij wisselstroom toestellen de stekker van het netsnoer uit het stopcontact te halen; voor gelijkstroom toestellen dient u de stroom uit te schakelen bij de stroomverbreker.
Varoitus Kytke irti vaihtovirtalaitteiden virtajohto ja katkaise tasavirtalaitteiden virta suojakytkimellä, ennen kuin teet mitään asennuspohjalle tai työskentelet virtalähteiden läheisyydessä.
Attention Avant de travailler sur un châssis ou à proximité d'une alimentation
électrique, débrancher le cordon d'alimentation des unités en courant alternatif; couper l'alimentation des unités en courant continu au niveau du disjoncteur.
Warnung Bevor Sie an einem Chassis oder in der Nähe von Netzgeräten arbeiten, ziehen Sie bei Wechselstromeinheiten das Netzkabel ab bzw.
schalten Sie bei Gleichstromeinheiten den Strom am Unterbrecher ab.
Avvertenza Prima di lavorare su un telaio o intorno ad alimentatori, scollegare il cavo di alimentazione sulle unità CA; scollegare l'alimentazione all'interruttore automatico sulle unità CC.
Advarsel Før det utføres arbeid på kabinettet eller det arbeides i nærheten av strømforsyningsenheter, skal strømledningen trekkes ut p vekselstrømsenheter og strømmen kobles fra ved strømbryteren på likestrømsenheter.
Aviso Antes de trabalhar num chassis, ou antes de trabalhar perto de unidades de fornecimento de energia, desligue o cabo de alimentação nas unidades de corrente alternada; desligue a corrente no disjuntor nas unidades de corrente contínua.
¡Atención!
Antes de manipular el chasis de un equipo o trabajar cerca de una fuente de alimentación, desenchufar el cable de alimentación en los equipos de corriente alterna (CA); cortar la alimentación desde el interruptor automático en los equipos de corriente continua (CC).
Varning!
Innan du arbetar med ett chassi eller nära strömförsörjningsenheter skall du för växelströmsenheter dra ur nätsladden och för likströmsenheter bryta strömmen vid överspänningsskyddet.
290 Copyright © 2019, Juniper Networks, Inc.
Chapter 39: Electrical Safety Guidelines and Warnings
Related
Documentation
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 293
General Electrical Safety Guidelines and Electrical Codes for M10i Routers
• Install the router in compliance with the following local, national, or international electrical codes:
• United States—National Fire Protection Association (NFPA 70), United States
National Electrical Code.
• Canada—Canadian Electrical Code, Part 1, CSA C22.1.
• Other countries—International Electromechanical Commission (IEC) 60364, Part 1 through Part 7.
• Locate the emergency power-off switch for the room in which you are working so that if an electrical accident occurs, you can quickly turn off the power.
• Do not work alone if potentially hazardous conditions exist anywhere in your workspace.
• Never assume that power is disconnected from a circuit. Always check the circuit before starting to work.
• Carefully look for possible hazards in your work area, such as moist floors, ungrounded power extension cords, and missing safety grounds.
• Operate the router within marked electrical ratings and product usage instructions.
• For the router and peripheral equipment to function safely and correctly, use the cables and connectors specified for the attached peripheral equipment, and make certain they are in good condition.
Many router components can be removed and replaced without powering off or disconnecting power to the router. Never install equipment if it appears damaged.
Related
Documentation
•
General Electrical Safety Warnings for Juniper Networks Devices on page 287
M10i AC Power Electrical Safety Guidelines
The following electrical safety guidelines apply to AC-powered routers:
• AC-powered routers are shipped with a three-wire electrical cord with a grounding-type plug that fits only a grounding-type power outlet. Do not circumvent this safety feature.
Equipment grounding should comply with local and national electrical codes.
• You must provide an external circuit breaker rated minimum 15 A (250 VAC) in the building installation.
• The AC power cord serves as the main disconnecting device. The socket outlet must be near the router and be easily accessible.
• The cores in the mains lead are colored in accordance with the following code:
Copyright © 2019, Juniper Networks, Inc.
291
M10i Multiservice Edge Router Hardware Guide
• Green and yellow—Earth
• Blue—Neutral
• Brown—Live
• When a router is equipped with multiple AC power supplies, all AC power cords (one for each power supply) must be unplugged to completely disconnect power to the router.
• Note the following warnings printed on the AC power supply faceplate:
• To completely de-energize the system disconnect maximum of 2 AC power cordsets.
• Apparaten skall anslutas till jordat uttag när den ansluts till ett nätverk. [Swedish]
Related
Documentation
•
Preventing Electrostatic Discharge Damage to an M10i Router on page 264
•
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 291
•
M10i DC Power Electrical Safety Guidelines on page 292
Japanese AC Power Cord Warning for M Series and MX Series Routers
WARNING:
Translation from Japanese: The attached power cable is only for this product.
Do not use the cable for another product.
Related
Documentation
M10i DC Power Electrical Safety Guidelines
The following electrical safety guidelines apply to a DC-powered router:
• A DC-powered router is equipped with a DC terminal block that is rated for the power requirements of a maximally configured router. To supply sufficient power, terminate the DC input wiring on a facility DC source capable of supplying at least 31 A @ –48 VDC per input for each power supply.
• Incorporate an easily accessible disconnect device into the facility wiring. We recommend that the 48 VDC facility DC source should be equipped with a circuit
292 Copyright © 2019, Juniper Networks, Inc.
Chapter 39: Electrical Safety Guidelines and Warnings breaker rated at 40 A (–48 VDC) minimum, or as required by local code. In the United
States and Canada, the 48 VDC facility should be equipped with a circuit breaker rated a minimum of 125% of the power provisioned for the input in accordance with the
National Electrical Code in the US and the Canadian Electrical Code in Canada.
• Run two wires from the circuit breaker box to a source of 48 VDC. Use appropriate gauge wire to handle up to 50 A.
• Be sure to connect the ground wire or conduit to a solid office (earth) ground. A closed loop ring is recommended for terminating the ground conductor at the ground stud.
• A DC-powered router that is equipped with a DC terminal block is intended only for installation in a restricted access location. In the United States, a restricted access area is one in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical
Code ANSI/NFPA 70.
NOTE: Primary overcurrent protection is provided by the building circuit breaker. This breaker should protect against excess currents, short circuits, and earth faults in accordance with NEC ANSI/NFPA70.
• Ensure that the polarity of the DC input wiring is correct. Under certain conditions, connections with reversed polarity might trip the primary circuit breaker or damage the equipment.
• For personal safety, connect the green and yellow wire to safety (earth) ground at both the router and the supply side of the DC wiring.
• The marked input voltage of –48 VDC for a DC-powered router is the nominal voltage associated with the battery circuit, and any higher voltages are only to be associated with float voltages for the charging function.
• Because the router is a positive ground system, you must connect the positive lead to the terminal labeled RETURN , the negative lead to the terminal labeled –48V , and the earth ground to the chassis grounding points.
Related
Documentation
•
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 293
•
General Electrical Safety Warnings for Juniper Networks Devices on page 287
DC Power Electrical Safety Warnings for Juniper Networks Devices
When working with DC-powered equipment, observe the following warnings:
•
DC Power Copper Conductors Warning on page 294
•
DC Power Disconnection Warning on page 294
•
DC Power Wiring Terminations Warning on page 295
Copyright © 2019, Juniper Networks, Inc.
293
M10i Multiservice Edge Router Hardware Guide
DC Power Copper Conductors Warning
WARNING: Use copper conductors only.
Waarschuwing Gebruik alleen koperen geleiders.
Varoitus Käytä vain kuparijohtimia.
Attention Utilisez uniquement des conducteurs en cuivre.
Warnung Verwenden Sie ausschließlich Kupferleiter.
Avvertenza Usate unicamente dei conduttori di rame.
Advarsel Bruk bare kobberledninger.
Aviso Utilize apenas fios condutores de cobre.
¡Atención!
Emplee sólo conductores de cobre.
Varning!
Använd endast ledare av koppar.
DC Power Disconnection Warning
WARNING: Before performing any procedures on power supplies, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.
Waarschuwing Voordat u een van de onderstaande procedures uitvoert, dient u te controleren of de stroom naar het gelijkstroom circuit uitgeschakeld is. Om u ervan te verzekeren dat alle stroom UIT is geschakeld, kiest u op het schakelbord de stroomverbreker die het gelijkstroom circuit bedient, draait de stroomverbreker naar de UIT positie en plakt de schakelaarhendel van de stroomverbreker met plakband in de UIT positie vast.
Varoitus Varmista, että tasavirtapiirissä ei ole virtaa ennen seuraavien toimenpiteiden suorittamista. Varmistaaksesi, että virta on KATKAISTU täysin, paikanna tasavirrasta huolehtivassa kojetaulussa sijaitseva suojakytkin, käännä suojakytkin KATKAISTU-asentoon ja teippaa suojakytkimen varsi niin, että se pysyy KATKAISTU-asennossa.
Attention Avant de pratiquer l'une quelconque des procédures ci-dessous, vérifier que le circuit en courant continu n'est plus sous tension. Pour en être sûr, localiser le disjoncteur situé sur le panneau de service du circuit en courant continu, placer le disjoncteur en position fermée (OFF) et, à l'aide d'un ruban adhésif, bloquer la poignée du disjoncteur en position OFF.
294 Copyright © 2019, Juniper Networks, Inc.
Chapter 39: Electrical Safety Guidelines and Warnings
Warnung Vor Ausführung der folgenden Vorgänge ist sicherzustellen, daß die Gleichstromschaltung keinen Strom erhält. Um sicherzustellen, daß sämtlicher Strom abgestellt ist, machen Sie auf der Schalttafel den
Unterbrecher für die Gleichstromschaltung ausfindig, stellen Sie den
Unterbrecher auf AUS, und kleben Sie den Schaltergriff des Unterbrechers mit Klebeband in der AUS-Stellung fest.
Avvertenza Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC non sia alimentato. Per verificare che tutta l'alimentazione sia scollegata (OFF), individuare l'interruttore automatico sul quadro strumenti che alimenta il circuito CC, mettere l'interruttore in posizione OFF e fissarlo con nastro adesivo in tale posizione.
Advarsel Før noen av disse prosedyrene utføres, kontroller at strømmen er frakoblet likestrømkretsen. Sørg for at all strøm er slått AV. Dette gjøres ved
å lokalisere strømbryteren på brytertavlen som betjener likestrømkretsen, slå strømbryteren AV og teipe bryterhåndtaket på strømbryteren i AV-stilling.
Aviso Antes de executar um dos seguintes procedimentos, certifique-se que desligou a fonte de alimentação de energia do circuito de corrente contínua.
Para se assegurar que toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente contínua e coloque-o na posição OFF
(Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora.
¡Atención!
Antes de proceder con los siguientes pasos, comprobar que la alimentación del circuito de corriente continua (CC) esté cortada (OFF). Para asegurarse de que toda la alimentación esté cortada (OFF), localizar el interruptor automático en el panel que alimenta al circuito de corriente continua, cambiar el interruptor automático a la posición de Apagado (OFF), y sujetar con cinta la palanca del interruptor automático en posición de
Apagado (OFF).
Varning!
Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare i FRÅN-läget.
DC Power Wiring Terminations Warning
WARNING: When stranded wiring is required, use approved wiring terminations, such as closed-loop or spade-type with upturned lugs. These terminations must be the appropriate size for the wires and must clamp both the insulation and conductor.
Waarschuwing Wanneer geslagen bedrading vereist is, dient u bedrading te gebruiken die voorzien is van goedgekeurde aansluitingspunten, zoals het
Copyright © 2019, Juniper Networks, Inc.
295
M10i Multiservice Edge Router Hardware Guide gesloten-lus type of het grijperschop type waarbij de aansluitpunten omhoog wijzen. Deze aansluitpunten dienen de juiste maat voor de draden te hebben en dienen zowel de isolatie als de geleider vast te klemmen.
Varoitus Jos säikeellinen johdin on tarpeen, käytä hyväksyttyä johdinliitäntää, esimerkiksi suljettua silmukkaa tai kourumaista liitäntää, jossa on ylöspäin käännetyt kiinnityskorvat. Tällaisten liitäntöjen tulee olla kooltaan johtimiin sopivia ja niiden tulee puristaa yhteen sekä eristeen että johdinosan.
Attention Quand des fils torsadés sont nécessaires, utiliser des douilles terminales homologuées telles que celles à circuit fermé ou du type à plage ouverte avec cosses rebroussées. Ces douilles terminales doivent être de la taille qui convient aux fils et doivent être refermées sur la gaine isolante et sur le conducteur.
Warnung Wenn Litzenverdrahtung erforderlich ist, sind zugelassene
Verdrahtungsabschlüsse, z.B. Ringoesen oder gabelförmige Kabelschuhe mit nach oben gerichteten Enden zu verwenden. Diese Abschlüsse sollten die angemessene Größe für die Drähte haben und sowohl die Isolierung als auch den Leiter festklemmen.
Avvertenza Quando occorre usare trecce, usare connettori omologati, come quelli a occhiello o a forcella con linguette rivolte verso l'alto. I connettori devono avere la misura adatta per il cablaggio e devono serrare sia l'isolante che il conduttore.
Advarsel Hvis det er nødvendig med flertrådede ledninger, brukes godkjente ledningsavslutninger, som for eksempel lukket sløyfe eller spadetype med oppoverbøyde kabelsko. Disse avslutningene skal ha riktig størrelse i forhold til ledningene, og skal klemme sammen både isolasjonen og lederen.
Aviso Quando forem requeridas montagens de instalação eléctrica de cabo torcido, use terminações de cabo aprovadas, tais como, terminações de cabo em circuito fechado e planas com terminais de orelha voltados para cima.
Estas terminações de cabo deverão ser do tamanho apropriado para os respectivos cabos, e deverão prender simultaneamente o isolamento e o fio condutor.
¡Atención!
Cuando se necesite hilo trenzado, utilizar terminales para cables homologados, tales como las de tipo "bucle cerrado" o "espada", con las lengüetas de conexión vueltas hacia arriba. Estos terminales deberán ser del tamaño apropiado para los cables que se utilicen, y tendrán que sujetar tanto el aislante como el conductor.
Varning!
När flertrådiga ledningar krävs måste godkända ledningskontakter användas, t.ex. kabelsko av sluten eller öppen typ med uppåtvänd tapp.
Storleken på dessa kontakter måste vara avpassad till ledningarna och måste kunna hålla både isoleringen och ledaren fastklämda.
296 Copyright © 2019, Juniper Networks, Inc.
Chapter 39: Electrical Safety Guidelines and Warnings
Related
Documentation
•
General Safety Warnings for Juniper Networks Devices on page 262
•
General Electrical Safety Warnings for Juniper Networks Devices on page 287
Copyright © 2019, Juniper Networks, Inc.
297
M10i Multiservice Edge Router Hardware Guide
298 Copyright © 2019, Juniper Networks, Inc.
CHAPTER 40
Agency Approvals and Compliance
Statements
•
Agency Approvals for M10i Routers on page 299
•
Compliance Statements for EMC Requirements for Juniper Networks Devices
•
Compliance Statements for EMC Requirements for M10i Routers (European
•
Compliance Statements for EMC Requirements for Juniper Networks Devices
•
Compliance Statements for EMC Requirements for Juniper Networks Devices
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
•
Compliance Statements for Environmental Requirements on page 302
•
M10i Compliance Statements for NEBS on page 302
•
Compliance Statements for Acoustic Noise for M10i Routers on page 302
•
Statements of Volatility for Juniper Network Devices on page 303
Agency Approvals for M10i Routers
The router complies with the following standards:
• Safety
• CAN/CSA-22.2 No. 60950-00/UL 1950 Third Edition, Safety of Information
Technology Equipment
• EN 60825-1 Safety of Laser Products - Part 1: Equipment Classification, Requirements and User's Guide
• EN 60950 Safety of Information Technology Equipment
• EMC
• AS/NZS 3548 Class A (Australia/New Zealand)
• EN55022 Class A (Europe)
Copyright © 2019, Juniper Networks, Inc.
299
M10i Multiservice Edge Router Hardware Guide
• FCC Part 15 Class A (USA)
• VCCI Class B (Japan)
• Immunity
• EN-61000-3-2 Power Line Harmonics
• EN-61000-3-3 Voltage Fluctuations and Flicker
• EN-61000-4-2 ESD
• EN-61000-4-3 Radiated Immunity
• EN-61000-4-4 EFT
• EN-61000-4-5 Surge
• EN-61000-4-6 Low Frequency Common Immunity
• EN-61000-4-11 Voltage Dips and Sags
• ETSI
• ETSI EN-300386-2 Telecommunication Network Equipment. Electromagnetic
Compatibility Requirements
• NEBS
• GR-1089-Core: EMC and Electrical Safety for Network Telecommunications
Equipment
• SR-3580 NEBS Criteria Levels (Level 3 Compliance)
• GR-63-Core: NEBS, Physical Protection
Related
Documentation
•
M10i Compliance Statements for NEBS on page 302
•
Compliance Statements for EMC Requirements for M10i Routers (European Community) on page 301
•
Compliance Statements for Environmental Requirements on page 302
•
Compliance Statements for Acoustic Noise for M10i Routers on page 302
Compliance Statements for EMC Requirements for Juniper Networks Devices (Canada)
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Related
Documentation
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Israel) on page 301
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan) on page 301
300 Copyright © 2019, Juniper Networks, Inc.
Chapter 40: Agency Approvals and Compliance Statements
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
Compliance Statements for EMC Requirements for M10i Routers (European
Community)
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Related
Documentation
•
Agency Approvals for M10i Routers on page 299
Compliance Statements for EMC Requirements for Juniper Networks Devices (Israel)
Translation from Hebrew—Warning: This product is Class A. In residential environments, the product may cause radio interference, and in such a situation, the user may be required to take adequate measures.
Related
Documentation
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Canada) on page 300
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan) on page 301
•
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
Compliance Statements for EMC Requirements for Juniper Networks Devices (Japan)
Related
Documentation
Translation from Japanese—This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. VCCI-A
Copyright © 2019, Juniper Networks, Inc.
301
M10i Multiservice Edge Router Hardware Guide
Compliance Statements for EMC Requirements for Juniper Networks Devices (United
States)
The hardware equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Related
Documentation
•
Compliance Statements for Environmental Requirements
Batteries in this product are not based on mercury, lead, or cadmium substances. The batteries used in this product are in compliance with EU Directives 91/157/EEC, 93/86/EEC, and 98/101/EEC. The product documentation includes instructional information about the proper method of reclamation and recycling.
M10i Compliance Statements for NEBS
• The equipment is suitable for installation as part of the Common Bonding Network
(CBN).
• The equipment is suitable for installation in locations where the National Electrical
Code (NEC) applies.
• The battery return connection is to be treated as an isolated DC return (that is, DC-I), as defined in GR-1089-CORE.
• You must provision a readily accessible device outside of the equipment to disconnect power. The device must also be rated based on local electrical code practice.
Related
Documentation
•
Agency Approvals for M10i Routers on page 299
•
Compliance Statements for EMC Requirements for M10i Routers (European Community) on page 301
•
Compliance Statements for Environmental Requirements on page 302
•
Compliance Statements for Acoustic Noise for M10i Routers on page 302
Compliance Statements for Acoustic Noise for M10i Routers
The router complies with NEBS Level 3 requirements:
• GR-63-CORE: NEBS, Physical Protection
302 Copyright © 2019, Juniper Networks, Inc.
Chapter 40: Agency Approvals and Compliance Statements
• GR-1089-CORE: EMC and Electrical Safety for Network Telecommunications Equipment
Related
Documentation
•
Agency Approvals for M10i Routers on page 299
•
M10i Compliance Statements for NEBS on page 302
•
Compliance Statements for EMC Requirements for M10i Routers (European Community) on page 301
•
Compliance Statements for Environmental Requirements on page 302
Statements of Volatility for Juniper Network Devices
A statement of volatility —sometimes known as letter of volatility —identifies the volatile and non-volatile storage components in Juniper Networks devices, and describes how to remove non-volatile storage components from the device.
NOTE: Statements of volatility are not available for all Juniper Networks devices.
CTP series:
• CTP2000
EX series:
• EX2200 and EX2200-C
• EX2300-24P, EX2300-24T, and EX2300-24T-DC
• EX2300-48P and EX2300-48T
• EX2300-C
• EX3300
• EX3400-24P, EX3400-24T, EX3400-24T-DC
• EX3400-48P, EX3400-48T, EX3400-48T-AFI
• EX4200
• EX4300
• EX4500
• EX4550
• EX4600
• EX8200
• XRE200 External Routing Engine
Copyright © 2019, Juniper Networks, Inc.
303
M10i Multiservice Edge Router Hardware Guide
LN Series:
• LN1000–CC
MX series:
• M7i
• M7i Compact Forwarding Engine Board (CFEB)
• M40e and M10i
• M320
• MX5, MX10, MX40, and MX80
• MX240, MX480, and MX960
• RE-A-2000 Route Engine
• RE-S-X6-64G Routing Engine
QFX series:
• QFX3008-I
• QFX3100
• QFX3500
• QFX3600
• QFX5100-24Q
• QFX5100-48S6Q
• QFX5100-48T
• QFX5200
• QFX5200-32C
• QFX10008 and QFX10016
SRX series:
• SRX100
• SRX110
• SRX210B
• SRX210H-POE
• SRX210H-P-MGW
• SRX220
• SRX240H
• SRX240H-POE
• SRX300
304 Copyright © 2019, Juniper Networks, Inc.
• SRX320
• SRX340 and SRX345
• SRX550
• SRX650
• SRX1400
• SRX1500
• SRX3400 and SRX3600
• SRX5400, SRX5600, and SRX5800
• SRX-MP-1SERIAL
• SSG-520M
T series:
• RE-A-2000 Route Engine
Chapter 40: Agency Approvals and Compliance Statements
Copyright © 2019, Juniper Networks, Inc.
305
M10i Multiservice Edge Router Hardware Guide
306 Copyright © 2019, Juniper Networks, Inc.
Download