Psion Teklogix 9500 Communications Server User Manual
Advertisement
Advertisement
9500
Communications Server
User Manual — Part Two
February 2, 2005 Part No. 8000008.B
ISO 9001 Certified
Quality Management System
© Copyright 2005 by Psion Teklogix Inc., Mississauga, Ontario
This document and the information it contains is the property of Psion Teklogix Inc., is issued in strict confidence, and is not to be reproduced or copied, in whole or in part, except for the sole purpose of promoting the sale of Psion Teklogix manufactured goods and services. Furthermore, this document is not to be used as a basis for design, manufacture, or sub-contract, or in any manner detrimental to the interests of
Psion Teklogix Inc.
All trademarks are the property of their respective holders.
Return-To-Factory Warranty
Psion Teklogix warrants a return-to-factory warranty for a period of 90 days from shipment or 120 days from shipment where Psion Teklogix installs the equipment.
The warranty on Psion Teklogix manufactured equipment does not extend to any product that has been tampered with, altered, or repaired by any person other than an employee of an authorized Psion Teklogix service organization. See Psion Teklogix terms and conditions of sale for full details.
Service
When requesting service, please provide information concerning the nature of the failure and the manner in which the equipment was used when the failure occurred.
Type, model, and serial number should also be provided. Before returning any products to the factory, call the Customer Services Group for a Return
Authorization number.
Support Services
Psion Teklogix provides a complete range of product support services to its customers. For contact information and a listing of worldwide offices, please refer to Appendix F: “Support Services And Worldwide Offices”.
Disclaimer
Every effort has been made to make this material complete, accurate, and up-todate. Psion Teklogix Inc. reserves the right to make changes without notice and shall not be responsible for any damages, including but not limited to consequential damages, caused by reliance on the material presented, including but not limited to typographical errors.
T
ABLE OF
C
ONTENTS
Appendices
Appendix A: Ports, Pinouts And Cable Diagrams
A.1 RJ-45 Connector Pinout. . . . . . . . . . . . . . . . . . . . . . . . . A-3
A.2 Serial Connector Pinout (9-pin) . . . . . . . . . . . . . . . . . . . . . A-4
A.3 Cable Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5
Appendix B: Setting Terminal Numbers On The CommServer
B.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
B.1.1 The General Host Options Screen . . . . . . . . . . . . . . B-3
B.1.2 The Configure Existing Base Station Screen . . . . . . . . B-4
B.2 Setting The Terminal Range (Hosts) . . . . . . . . . . . . . . . . . . B-4
B.2.1 Systems With One Host . . . . . . . . . . . . . . . . . . . B-5
B.2.2 Systems With Multiple Hosts . . . . . . . . . . . . . . . . B-6
B.3 Setting The Terminal Range (Base Stations) . . . . . . . . . . . . . . B-9
Appendix C: The 9500 CommServer’s Web Interface
C.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3
C.1.1 About The 9500 CommServer’s Web Interface . . . . . . . C-3
C.1.2 The CommServer’s Host-Application Screens . . . . . . . C-3
C.1.2.1 The Host-Application Screens . . . . . . . . . .C-3
C.1.2.2 Limitations Of The Host-Application Screens . .C-5
C.1.3 The CommServer’s Web Configuration Screens . . . . . . C-5
C.1.3.1 Items Common To Many Screens. . . . . . . . .C-8
C.1.3.2 Finding Screens . . . . . . . . . . . . . . . . . .C-9
C.1.3.3 Maps Of The CommServer’s Web Interface . . C-12
C.2 The Web Configuration Screens . . . . . . . . . . . . . . . . . . . C-14
C.2.1 The Configuration Main Menu Screen . . . . . . . . . . C-14
C.2.1.1 Controller Configuration . . . . . . . . . . . . C-15
C.2.1.2 Redundancy Configuration . . . . . . . . . . . C-16
Psion Teklogix 9500 Communications Server User Manual
i
ii
Contents
C.2.1.3 SNA Protocol Configuration . . . . . . . . . . C-16
C.2.1.4 System Configuration . . . . . . . . . . . . . .C-17
C.2.1.5 Miscellaneous Commands. . . . . . . . . . . . C-18
C.2.2 Controller Configuration: The Host Screens. . . . . . . . C-19
C.2.2.1 Configure New Host. . . . . . . . . . . . . . .C-19
C.2.2.2 The Host Menu . . . . . . . . . . . . . . . . . C-22
C.2.2.3 General Host Options . . . . . . . . . . . . . . C-23
C.2.2.4 Emulation Options. . . . . . . . . . . . . . . . C-26
C.2.2.5 Protocol Options . . . . . . . . . . . . . . . . . C-87
C.2.2.6 Function Key Mapping . . . . . . . . . . . . C-123
C.2.3 CommServer Configuration: The Base Station Screens . C-132
C.2.3.1 Configure New Base Station . . . . . . . . . C-133
C.2.3.2 The Base Station Menu . . . . . . . . . . . . C-135
C.2.3.3 General Options . . . . . . . . . . . . . . . . C-136
C.2.3.4 Connectivity Options . . . . . . . . . . . . . C-139
C.2.4 CommServer Configuration: The RRM Groups Screens C-140
C.2.4.1 Configure New RRM Group . . . . . . . . . C-142
C.2.4.2 The RRM Group Menu . . . . . . . . . . . . C-149
C.2.4.3 Configure Existing RRM Group. . . . . . . . C-151
C.2.4.4 Configure New RRM . . . . . . . . . . . . . C-153
C.2.4.5 Configure Existing RRM . . . . . . . . . . . C-154
C.2.4.6 Analyze RRM Group . . . . . . . . . . . . . C-156
C.2.5 CommServer Configuration: Radio Link Features . . . C-160
C.2.6 CommServer Configuration: 802.IQ v1 And v2 Features C-165
C.2.7 Redundancy Options . . . . . . . . . . . . . . . . . . . C-168
C.2.8 System Configuration: SNA Parameters. . . . . . . . . C-172
C.2.9 System Configuration: The Users Screens. . . . . . . . C-173
C.2.9.1 Create New User Entry . . . . . . . . . . . . C-173
C.2.9.2 Edit Existing User Entry. . . . . . . . . . . . C-174
C.2.10 System Configuration: SNMP Parameters. . . . . . . . C-176
C.2.11 System Configuration: Miscellaneous System Options . C-177
C.2.12 Miscellaneous Commands . . . . . . . . . . . . . . . . C-179
C.2.12.1 Display Entire Database Contents . . . . . . . C-179
C.2.12.2 Restart The CommServer Software . . . . . . C-180
C.2.12.3 Validate and Save Database Contents . . . . . C-181
Appendix D: Developing HTML For The CommServer
D.1 Limitations Of The CommServer’s HTML/TESS Emulation. . . . . .D-3
Psion Teklogix 9500 Communications Server User Manual
Contents
D.2 Supported HTML Tags . . . . . . . . . . . . . . . . . . . . . . . . . D-4
D.2.1 Link, Miscellaneous, And Input Tags . . . . . . . . . . . . D-5
D.2.2 Text Attribute Tags . . . . . . . . . . . . . . . . . . . . . D-7
D.2.3 Text Formatting Tags . . . . . . . . . . . . . . . . . . . . D-8
D.2.4 Table, List and Definition Tags . . . . . . . . . . . . . . . D-9
D.3 Function Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-11
D.3.1 Mapping The Function Keys . . . . . . . . . . . . . . . D-11
D.3.1.1 Mapping A Function Key To A Hyperlink . . . D-11
D.3.1.2 Mapping A Function Key To A Button . . . . . D-11
D.3.2 Tags Without Function-Key Support . . . . . . . . . . . D-12
D.3.3 Predefined Function Keys . . . . . . . . . . . . . . . . . D-12
D.3.4 Remapping Function-Key Zero (F0) . . . . . . . . . . . D-13
D.4 HTML Extensions For TESS . . . . . . . . . . . . . . . . . . . . . D-14
D.4.1 TEKFLAGS Within The <INPUT> Tag . . . . . . . . . D-14
D.4.2 TEKFLAGS Within The <TEKLOGIX> Tag . . . . . . D-14
D.4.3 The Flags For The TEKFLAGS Attribute . . . . . . . . D-15
D.5 Debugging And Testing With TekHTML. . . . . . . . . . . . . . . D-16
D.5.1 Emulator Debug . . . . . . . . . . . . . . . . . . . . . . D-16
D.5.2 Scheme Debug. . . . . . . . . . . . . . . . . . . . . . . D-17
D.5.3 Automatic Terminal Response Feature . . . . . . . . . . D-18
D.6 Cookies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-19
D.6.1 Overview Of Cookie Transfer . . . . . . . . . . . . . . . D-19
D.6.2 Implementation Of Cookies . . . . . . . . . . . . . . . . D-20
D.6.2.1 Difference In Cookie Expiration Mechanism . . D-20
D.6.2.2 Differences In Returned Data . . . . . . . . . . D-21
D.6.2.3 Differences In Punctuation . . . . . . . . . . . D-22
Appendix E: Software License Agreements
E.1 For Psion Teklogix Software . . . . . . . . . . . . . . . . . . . . . . E-3
E.2 For IBM Personal Communications Software . . . . . . . . . . . . . E-8
Appendix F: Support Services And Worldwide Offices
F.1 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1
F.2 Product Repairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1
F.3 Worldwide Offices . . . . . . . . . . . . . . . . . . . . . . . . . . . F-2
Psion Teklogix 9500 Communications Server User Manual
iii
A
PPENDIX
P
ORTS
, P
INOUTS
A
ND
C
ABLE
D
IAGRAMS
A
A.1 RJ-45 Connector Pinout . . . . . . . . . . . . . . . . . . . . A-3
A.2 Serial Connector Pinout (9-pin) . . . . . . . . . . . . . . . . A-4
A.3 Cable Descriptions . . . . . . . . . . . . . . . . . . . . . . A-5
DTE-DCE (Modem) Cable for 9400 (P.N. 19680). . . . A-6
DTE-DTE (Null-Modem) Cable for 9400 (P.N. 19687) . A-6
DTE-DTE (Null-Modem) Cable for 9500 (P.N. 3002186) A-7
Psion Teklogix 9500 Communications Server User Manual
A-1
A.1 RJ-45 Connector Pinout
Appendix A: Ports, Pinouts And Cable Diagrams
RJ-45 Connector Pinout
6
7
8
4
5
2
3
Pin
1 TD+
Signal
TD–
RD+
Not used
Not used
RD–
Not used
Not used
Note: Usually, a straight-through connection is needed to connect Twisted-Pair
(10-BaseT) to the hub. In some situations, a cable that crosses TD and
RD may be needed (for example, when connecting together two network controllers).
Psion Teklogix 9500 Communications Server User Manual
A-3
Appendix A: Ports, Pinouts And Cable Diagrams
Serial Connector Pinout (9-pin)
A.2 Serial Connector Pinout (9-pin)
Pin
5
6
7
8
9
1
2
3
4
RS-232 Signal
CD (Carrier Detect)
RD (Receive Data)
TD (Transmit Data)
DTR (Data Terminal Ready)
SG (Signal Ground)
DSR (Data Set Ready)
RTS (Ready To Send)
CTS (Clear To Send)
RI (Ring Indicator)
A-4
Psion Teklogix 9500 Communications Server User Manual
Appendix A: Ports, Pinouts And Cable Diagrams
Cable Descriptions
A.3 Cable Descriptions
19680
19687
3002186
RS-232
RS-232
RS-232
Cable Type
modem
(DTE to DCE) null-modem
(DTE to DTE) null-modem
(DTE to DTE)
Connector
9-pin to 25-pin
9-pin to 9-pin
9-pin to 9-pin
Asynchronous
Asynchronous
Asynchronous
Note: Cable 3002186 is necessary for a local serial PPP connection to the 9500
Communications Server hardware. It passes the DTR and DSR signals, which Windows RAS Server requires.
Psion Teklogix 9500 Communications Server User Manual
A-5
Appendix A: Ports, Pinouts And Cable Diagrams
Cable Descriptions
DTE-DCE (Modem) Cable for 9400 (P.N. 19680)
DTE-DTE (Null-Modem) Cable for 9400 (P.N. 19687)
A-6
Psion Teklogix 9500 Communications Server User Manual
Appendix A: Ports, Pinouts And Cable Diagrams
Cable Descriptions
DTE-DTE (Null-Modem) Cable for 9500 (P.N. 3002186)
DTE
CD
RD
TD
DTR
SG
DSR
RTS
CTS
RI
1
2
3
4
7
8
9
5
6
DE9-S
DTE
1
2
3
4
7
8
5
6
9
DE9-S
CD
RD
TD
DTR
SG
DSR
RTS
CTS
RI
Psion Teklogix 9500 Communications Server User Manual
A-7
A
PPENDIX
S
ETTING
T
ERMINAL
N
UMBERS
O
N
T
HE
C
OMM
S
ERVER
B
B.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . .B-3
B.1.1 The General Host Options Screen . . . . . . . . . .B-3
B.1.2 The Configure Existing Base Station Screen. . . . .B-4
B.2 Setting The Terminal Range (Hosts) . . . . . . . . . . . . . .B-4
B.2.1 Systems With One Host . . . . . . . . . . . . . . .B-5
B.2.2 Systems With Multiple Hosts. . . . . . . . . . . . .B-6
B.3 Setting The Terminal Range (Base Stations) . . . . . . . . . .B-9
Psion Teklogix 9500 Communications Server User Manual
B-1
Appendix B: Setting Terminal Numbers On The CommServer
Introduction
B.1 Introduction
Note: Unless stated otherwise, the information given in this appendix applies to
both TESS and ANSI hosts.
Several screens in the 9500 CommServer’s configuration interface allow you to specify ranges of terminal numbers:
• The General Host Options screen.
• The Configure Existing Base Station screen.
The terminal-numbering parameters on these screens interact to determine how terminals connect to hosts in the Psion Teklogix system.
B.1.1 The General Host Options Screen
The General Host Options screen contains the Terminal Range parameter for the host. It varies slightly depending on the name of the host. To obtain this screen:
1. Select the desired host from the Hosts listbox on the CommServer’s
Configuration Main Menu.
2. Press the Configure button next to the Hosts listbox. The CommServer displays the Host Menu.
3. Press the Configure button next to General Options on the Host Menu.
The CommServer displays the General Host Options screen.
See “General Host Options” on page C-23 for more information about this screen.
Psion Teklogix 9500 Communications Server User Manual
B-3
Appendix B: Setting Terminal Numbers On The CommServer
The Configure Existing Base Station Screen
B.1.2 The Configure Existing Base Station Screen
The Configure Existing Base Station screen contains the First Terminal parameter for the base station. To obtain this screen:
1. Select the desired base station from the Base Stations listbox on the
CommServer’s Configuration Main Menu.
2. Press the Configure button next to the Base Stations listbox. The
CommServer displays the Base Station Menu.
3. Press the Configure button next to General Options on the Base Station
Menu. The CommServer displays the Configure Existing Base Station screen.
See “General Options” on page C-136 for more information about this screen.
B.2 Setting The Terminal Range (Hosts)
The Terminal Range in each General Host Options screen represents host emulation numbers. It maps terminal numbers on the host to the host emulations on the 9500
CommServer. A range of n terminals (“host emulations”) in the host screen matches the lower number in the range to the first terminal defined on this host and the higher number in the range to the nth terminal defined on this host.
B-4
Psion Teklogix 9500 Communications Server User Manual
Appendix B: Setting Terminal Numbers On The CommServer
Systems With One Host
When the range starts at 1, the host terminal number is identical to the host emulation number (in other words – the offset is equal to zero). When the range starts with a number other than 1, an offset is created (equal to the lower number minus 1). For instance, the range “10 to 20” sets an offset of 9, and matches the first terminal on this host to host emulation #10.
The examples in this chapter demonstrate the effect of such offsets.
Note: In the following examples, no offsets were defined in the Base Station
screens (base-station offsets are explained in Section B.3 on page 9).
Thus, in these examples, the terminal ID numbers match the host emulation numbers.
B.2.1 Systems With One Host
If the 9500 CommServer is configured for one host, the range of terminals defined in the “Host 1” screen will be 1 to n , where n is the total number of terminals (“host emulations”) defined in the main Configuration screen. Thus, the offset is zero for
systems with only one host, and the ID numbers of the RF terminals are identical to the host emulation numbers.
Example:
Host 1
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
(=Terminal ID Numbers)
Terminal ID #1 Terminal ID #20
Figure B.1
In this system, we will define the ranges:
In the General Host Options screen for Host 1:
Terminal Range = 1 to 20
since this range starts at “1”, the offset for this host is zero, and the RF terminal ID numbers will be identical to the host emulation numbers
Psion Teklogix 9500 Communications Server User Manual
B-5
Appendix B: Setting Terminal Numbers On The CommServer
Systems With Multiple Hosts
In the Configure Existing Base Station screen for Base Station 1:
First Terminal = 1 no offset on the Base Station
B.2.2 Systems With Multiple Hosts
Terminal number mapping (offsets) become useful when the 9500 CommServer is configured for multiple hosts, and there is a need to differentiate between terminals that communicate with one host and those that communicate with another.
The ranges defined for the hosts can either overlap or be mutually exclusive, depending on the desired result.
Important: YOU CANNOT OVERLAP AN ANSI HOST WITH ANOTHER
ANSI HOST OR WITH A TESS HOST!
Examples:
Two hosts with no overlap in terminal numbers
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
10 11 12 13 14 15 16 17 18 19 20
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
(=Terminal ID Numbers)
Terminal ID #1 Terminal ID #20
Figure B.2
In this system, we will define the ranges:
In the CommServer’s General Host Options screen for Host 1:
Terminals = 1 to 9 a range of 9 terminals (or “host emulations”) for
Host #1. Since this range starts at “1”, the offset for this host is zero
In the CommServer’s Configure Existing Base Station screen for Base Station
1:
First Terminal = 1 no offset on the Base Station.
B-6
Psion Teklogix 9500 Communications Server User Manual
Appendix B: Setting Terminal Numbers On The CommServer
Systems With Multiple Hosts
In our diagram, we align the first terminal on Host 1 with host emulation #1:
Host Emulations on CommServer
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1
2 3 4 5 6 7 8 9
Host 1
1 2 3 4 5 6 7 8 9 10 11 Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
Range of Host 1 begins at "host emulation" #1
Terminal ID #1
Figure B.3
In the CommServer’s General Host Options screen for Host 2:
Terminal Range = 10 to 20
a range of 11 terminals (or “host emulations”). The lower
number in the range – host emulation #10 in this case – is mapped to the first terminal on Host #2, and the higher number – host emulation #20 in this case – is mapped to the 11th terminal on Host #2
In our diagram, we align the first terminal on Host 2 with host emulation #10:
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9
10
11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
1
2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
Range of Host 2 begins at "host emulation" #10
Terminal ID #1
Figure B.4
If, for instance, you assign the ID number of 13 to an RF terminal, it would correspond to the 4th terminal on Host #2.
In this example, no RF terminals fall within the ranges of both Host 1 and Host 2.
Thus, no RF terminal can communicate with both hosts.
Psion Teklogix 9500 Communications Server User Manual
B-7
Appendix B: Setting Terminal Numbers On The CommServer
Systems With Multiple Hosts
Note: If one host is a TESS host and the other an ANSI host, the terminal parameters will have to be set so that the “ANSI” terminal number indeed falls within the range defined on the 9500 CommServer for the ANSI host, and the “TESS” terminal number within the range defined on the
CommServer for the TESS host (refer to the appropriate terminal user manuals for information about how to set these parameters).
Two hosts with overlap in terminal numbers
Important: YOU CANNOT OVERLAP AN ANSI HOST WITH EITHER
ANOTHER ANSI HOST OR WITH A TESS HOST!
All examples with overlapping host terminal ranges assume both hosts to be TESS hosts.
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Host 1
1 2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
(=Terminal ID Numbers)
Terminal ID #1 Terminal ID #20
Figure B.5
In this system, we will define the ranges:
In the General Host Options screen for Host 1:
Terminal Range = 1 to 20
a range of 20 terminals (or “host emulations”). Since this range starts at “1”, the offset for this host is zero
In the General Host Options screen for Host 2:
Terminal Range = 10 to 20
range of 11 terminals (or “host emulations”). The lower
number in the range – host emulation #10 in this case – is mapped to the first terminal on Host #2, and the higher number – host emulation #20 in this case – is mapped to the 11th terminal on Host #2
B-8
Psion Teklogix 9500 Communications Server User Manual
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
In the Configure Existing Base Station screen for Base Station 1:
First Terminal = 1 (no offset on the Base Station).
In this example, RF terminals (and host emulations) #10 – #20 fall within the ranges of both Host 1 and Host 2 and will, therefore, be able to communicate with both of them. For instance, Psion Teklogix RF terminal #13 corresponds to terminal #13 on
Host #1 and to terminal #4 on Host #2 and will be given a choice of hosts with which to communicate (assuming they are both “TESS” hosts).
RF terminals (and host emulations) #1 – #9 fall within the range of Host 1 only and will therefore only be able to communicate with Host 1. These terminals will not be given a choice of hosts with which to communicate. In other words, when the user sets the terminal ID to a number between 1 and 9, the 9500 CommServer finds only
one match for that host emulation and knows which host terminal to associate with this ID number.
However, when the user sets the terminal ID to a number between 10 and 20, the
CommServer can find two matches for that host emulation, and will present the user with the choice between them. If, for instance, the terminal ID number is set to 13, the user can choose to be either terminal #13 on Host 1 or terminal 4 on Host 2.
B.3 Setting The Terminal Range (Base Stations)
The terminal ranges in the Configure Existing Base Station screens also act as offsets. However, these offsets are in the “opposite” sense to those of the offsets in the General Host Options screens. The range specified in the Configure Existing
Base Station screens maps the host emulations to the terminal ID numbers.
The range of terminals in the Configure Existing Base Station screen is specified using the “First Terminal=” parameter. The value entered in this parameter is always mapped to RF terminal ID #1. For instance, entering a value of 10 sets an offset of
9, and matches host emulation #10 to RF terminal ID #1, host emulation #11 to RF
terminal ID #2, etc.
When the value is set to 1 (offset equals zero) – the RF terminal ID number is identical to the host emulation number. When the range starts with a number other than 1, an offset is created (equal to the parameter value minus 1).
In almost all situations, a value of 1 is used for this parameter on the Base Station screens. Thus, host emulation numbers and terminal ID numbers would be identical.
Psion Teklogix 9500 Communications Server User Manual
B-9
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
Note: The terminal number specified in the “First Terminal=” parameter is always mapped to RF terminal #1. This means that by using offsets, you
cannot create a range of terminals that will start with any other
RF terminal ID number!
If you want to separate the RF terminals into groups, each communicating with different Base Stations, the correct way to do so would be by
enabling/disabling the appropriate channels on the terminals themselves. Refer to the appropriate terminal user manuals for instructions.
Important: Only extremely rare situations call for offsets on base stations.
UNDER NORMAL CIRCUMSTANCES, NO OFFSET SHOULD
BE SET. EXTREME CAUTION IS ADVISED WHEN USING
OFFSETS!
The offset capability was introduced to accommodate very rare situations, such as:
• Host software that requires the terminal numbers to start at a number significantly higher than 1. If the Psion Teklogix terminal ID numbers were changed to this higher range, more response windows would be required.
This would cause an increase in the response time.
• A necessity for duplicate terminal ID numbers in two or more remote sites, where there is no chance of interference between the base stations.
B-10
Psion Teklogix 9500 Communications Server User Manual
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
Examples:
One host with one base station with offset
Host 1
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
1 2 3 4 5 6 7 8 9 10 11
Terminal ID #1
(=Terminal ID Numbers)
Terminal ID #11
Figure B.6
In this system, we will define the ranges:
In the General Host Options screen for Host 1:
Terminals = 1 to 20 a range of 20 terminals (or “host emulations”). Since this range starts at “1”, the offset for this host is zero
In the Configure Existing Base Station screen for Base Station 1:
First Terminal = 10 creates a range of 11 terminals. Host emulation #10 is mapped to RF terminal ID #1. The other terminals follow in sequence, finishing with host emulation #20 --
RF terminal ID #11
Psion Teklogix 9500 Communications Server User Manual
B-11
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
In our diagram, we align the first terminal on Base Station 1 with host emulation #10:
Host 1
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9
10
11 12 13 14 15 16 1718 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1 1
2 3 4 5 6 7 8 9 10 11
Terminal ID #1
Range of Base Station 1 begins at "host emulation" #10
Figure B.7
Since the range on Base Station #1 is partial to the total number of host emulations, there will be terminal numbers for which no matching host emulation is found (terminal #12 – #20 in our example). If you set a terminal ID to any of these numbers, you will not be able to communicate with the host!
Note: The situation depicted in this example is not a practical one, and is shown here just to demonstrate the effect of an offset on a base station.
One host with two base stations
In this system, we will define the ranges:
In the General Host Options screen for Host 1:
Terminals = 1 to 20 a range of 20 terminals (or “host emulations”). Since this range starts at “1”, the offset for this host is zero
In the Configure Existing Base Station screen for Base Station 1:
First Terminal = 1 since this will map host emulation #1 to RF terminal ID #1, the offset for this Base Station is zero. Thus, “host emulations” #1 - #20 will match terminal ID numbers
1 through 20
B-12
Psion Teklogix 9500 Communications Server User Manual
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
In the Configure Existing Base Station screen for Base Station 2:
First Terminal = 10 creates a range of 11 terminals. Host emulation #10 is mapped to RF terminal ID #1, an offset of 9. The upper range of terminals will be host emulation #20 (RF terminal
ID #11)
Thus, the result of this setup is:
Terminal ID #1–#9: have two matching host emulations
(one via Base Station 1, the other via Base Station 2).
For example – terminal ID #4 is mapped both to
“host emulation #4 (via Base Station 1) and to host emulation #13 (via Base Station 2)
Host 1
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
(=Terminal ID Numbers)
Terminal ID #1
Base Station 2
1 2 3 4 5 6 7 8 9 10 11
(=Terminal ID Numbers)
Terminal ID #1
Figure B.8
Psion Teklogix 9500 Communications Server User Manual
B-13
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
Terminal ID #10–#11: match both host emulation ranges, and can thus communicate with the host via both Base Stations
Host 1
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
10 11
12 13 14 15 16 17 18 19 20
Base Station 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
(=Terminal ID Numbers)
Terminal ID #1
Base Station 2
1 2 3 4 5 6 7 8 9 10 11
(=Terminal ID Numbers)
Terminal ID #1
Figure B.9
Terminal ID #12–#20: match only one host emulation, and can thus communicate with the host only via Base Station 1
Host 1
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
(=Terminal ID Numbers)
Terminal ID #1
Base Station 2
1 2 3 4 5 6 7 8 9 10 11
(=Terminal ID Numbers)
Terminal ID #1
Figure B.10
In this situation, it is possible to have two remote base stations, and two sets of terminals with the same ID numbers.
B-14
Psion Teklogix 9500 Communications Server User Manual
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
For instance, if each site has 9 terminals, with ID numbers from 1 to 9, the
CommServer will be able to distinguish between two identical terminal ID numbers by the base station to which they communicate. Terminal #1 in the first site is actually host emulation #1, and terminal #1 in the second site is actually host emulation #10.
Now, we can combine this effect with division of terminals between hosts, as is shown in the next example:
Two hosts with two base stations (a)
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
1 2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
(=Terminal ID Numbers)
Terminal ID #1 Terminal ID #20
1 2 3 4 5 6 7 8 9 10 11
Base Station 2
(=Terminal ID Numbers)
Terminal ID #1 Terminal ID #11
Figure B.11
In this system, we will define the ranges:
In the General Host Options screen for Host 1:
Terminals = 1 to 9 a range of 9 terminals (or “host emulations”) for Host 1.
Since this range starts at 1, the offset for this host is zero and the RF terminal ID numbers will be identical to the host emulation numbers
In the General Host Options: Host 2 screen:
Terminals = 10 to 20a range of 11 terminals (or “host emulations”) for Host #2.
The lower number in the range – host emulation #10 in this case – is mapped to the first terminal on Host #2, and the higher number – host emulation #20 in this
Psion Teklogix 9500 Communications Server User Manual
B-15
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
case – is mapped to the 11th terminal on Host #2 -- an offset of 9
In the Configure Existing Base Station screen for Base Station 1:
First Terminal = 1 since this will map host emulation #1 to RF terminal ID #1, the offset for this Base Station is zero. Thus, “host emulations” #1 - #20 will match terminal ID numbers
1 through 20
In the Configure Existing Base Station screen for Base Station 2:
First Terminal = 10 creates a range of 11 terminals. Host emulation #10 is mapped to RF terminal ID #1, an offset of 9. The upper range of terminals will be host emulation #20 (RF terminal
ID #11)
Thus, the result of this setup is:
Terminal ID #1–#9: can communicate to Host 1 only
(if communicating via Base Station 1)
or to Host 2 only
(if communicating via Base Station 2)
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
1 2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
Terminal ID #1
1 2 3 4 5 6 7 8 9 10 11
Base Station 2
Terminal ID #1
Figure B.12
B-16
Psion Teklogix 9500 Communications Server User Manual
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
Terminal ID #10–#11: can communicate to Host 2 only, using host emulation #1 & #2 if communicating via Base
Station 1 or using host emulation #10 & #11 if communicating via Base Station 2
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
1 2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
Terminal ID #1
1 2 3 4 5 6 7 8 9 10 11
Base Station 2
Terminal ID #1
(=Terminal ID Numbers)
Terminal ID #11
Figure B.13
Terminal ID #12–#20: can only communicate with Host 2 via
Base Station 1
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
1 2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
Terminal ID #1
(=Terminal ID Numbers)
1 2 3 4 5 6 7 8 9 10 11
Base Station 2
Terminal ID #1
(=Terminal ID Numbers)
Terminal ID #11
Figure B.14
Psion Teklogix 9500 Communications Server User Manual
B-17
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
This type of setup could be useful, for example, when you have two remote base stations, and want each set of terminals to start with ID #1. The CommServer will then be able to distinguish between two identical terminal ID numbers by the base station to which they communicate.
In this last example, terminal #1 in the first site is actually host emulation #1 (which belongs to Host 1), and terminal #1 in the second site is actually “host emulation”
#10 (which belongs to Host 2).
Our final example is even more complex than the last:
Two hosts with two base stations (b)
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
1 2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
Terminal ID #1
(=Terminal ID Numbers)
1 2 3 4 5 6 7 8 9 10 11 12 13
Base Station 2
(=Terminal ID Numbers)
Terminal ID #1
Figure B.15
Important: YOU CANNOT OVERLAP AN ANSI HOST WITH EITHER
ANOTHER ANSI HOST OR WITH A TESS HOST!
In this system, we will define the ranges:
In the General Host Options screen for Host 1:
Terminals = 1 to 9 a range of 9 terminals (or “host emulations”) for Host #1.
Since this range starts at 1, the offset for this host is zero and the RF terminal ID numbers will be identical to the host emulation numbers
In the General Host Options screen for Host 2:
Terminals = 6 to 16 a range of 11 terminals (or “host emulations”). The lower
B-18
Psion Teklogix 9500 Communications Server User Manual
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
number in the range – host emulation #6 in this case – is mapped to the first terminal on Host #2, and the higher number – host emulation #16 in this case – is mapped to the 11th terminal on Host #2, an offset of 5
In the Configure Existing Base Station screen for Base Station 1:
First Terminal = 1 since this will map host emulation #1 to RF terminal ID #1, the offset for this Base Station is zero. Thus, “host emulations” #1 - #20 will match terminal ID numbers
1 through 20
In the Configure Existing Base Station: screen for Base Station 2:
First Terminal = 8 creates a range of 13 terminals. Host emulation #8 is mapped to RF terminal ID #1, an offset of 7. The upper range of terminals will be host emulation #20 (RF terminal
ID #13)
Thus, the result of this setup is:
Terminal ID #1–#2: can communicate to Host 1 only
(when communicating via Base Station 1)
or
to both Host 1 and Host 2
(when communicating via Base Station 2).
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
1 2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Terminal ID #1
Base Station 1
1 2 3 4 5 6 7 8 9 10 11 12 13
Base Station 2
Terminal ID #1
Figure B.16
Psion Teklogix 9500 Communications Server User Manual
B-19
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
Terminal ID #3–#5: can communicate to Host 1 only
(when communicating via Base Station 1)
or
to Host 2 only
(when communicating via Base Station 2).
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
1 2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
Terminal ID #1
1 2 3 4 5 6 7 8 9 10 11 12 13
Base Station 2
Terminal ID #1
Figure B.17
Terminal ID #6–#9: can communicate to both Host 1 and Host 2
(when communicating via Base Station 1)
or
to Host 2 only
(when communicating via Base Station 2).
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 Host 1
1 2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
Terminal ID #1
1 2 3 4 5 6 7 8 9 10 11 12 13
Base Station 2
Terminal ID #1
Figure B.18
B-20
Psion Teklogix 9500 Communications Server User Manual
Appendix B: Setting Terminal Numbers On The CommServer
Setting The Terminal Range (Base Stations)
Terminal ID #10-#16: can communicate to Host 2 only
(via Base Station 1).
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
1 2 3 4 5 6 7 8 9 10 11 Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Base Station 1
Terminal ID #1
1 2 3 4 5 6 7 8 9 10 11 12 13
Base Station 2
Terminal ID #1
Figure B.19
Terminal ID #17–#20: cannot communicate with any host (no host is configured with a range or offset high enough).
Host Emulations on CommServer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9
Host 1
1 2 3 4 5 6 7 8 9 10 11
Host 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Terminal ID #1
Base Station 1
1 2 3 4 5 6 7 8 9 10 11 12 13
Base Station 2
Terminal ID #1
Figure B.20
Psion Teklogix 9500 Communications Server User Manual
B-21
A
PPENDIX
T
HE
9500 C
OMM
S
ERVER
’
S
W
EB
I
NTERFACE
C
C.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3
C.1.1 About The 9500 CommServer’s Web Interface . . . . . . C-3
C.1.2 The CommServer’s Host-Application Screens . . . . . . C-3
C.1.2.1 The Host-Application Screens . . . . . . . . . . . C-3
C.1.2.2 Limitations Of The Host-Application Screens . . . C-5
C.1.3 The CommServer’s Web Configuration Screens . . . . . C-5
C.1.3.1 Items Common To Many Screens . . . . . . . . . C-8
C.1.3.2 Finding Screens. . . . . . . . . . . . . . . . . . . C-9
C.1.3.3 Maps Of The CommServer’s Web Interface . . . C-12
C.2 The Web Configuration Screens . . . . . . . . . . . . . . . . . . C-14
C.2.1 The Configuration Main Menu Screen. . . . . . . . . . C-14
C.2.1.1 Controller Configuration . . . . . . . . . . . . . C-15
C.2.1.2 Redundancy Configuration. . . . . . . . . . . . C-16
C.2.1.3 SNA Protocol Configuration . . . . . . . . . . . C-16
C.2.1.4 System Configuration . . . . . . . . . . . . . . C-17
C.2.1.5 Miscellaneous Commands . . . . . . . . . . . . C-18
C.2.2 Controller Configuration: The Host Screens. . . . . . . C-19
C.2.2.1 Configure New Host . . . . . . . . . . . . . . . C-19
C.2.2.2 The Host Menu . . . . . . . . . . . . . . . . . . C-22
C.2.2.3 General Host Options. . . . . . . . . . . . . . . C-23
C.2.2.4 Emulation Options . . . . . . . . . . . . . . . . C-26
C.2.2.5 Protocol Options . . . . . . . . . . . . . . . . . C-87
C.2.2.6 Function Key Mapping . . . . . . . . . . . . . C-123
C.2.3 CommServer Configuration: The Base Station Screens C-132
C.2.3.1 Configure New Base Station . . . . . . . . . . C-133
C.2.3.2 The Base Station Menu. . . . . . . . . . . . . C-135
C.2.3.3 General Options . . . . . . . . . . . . . . . . C-136
Psion Teklogix 9500 Communications Server User Manual
C-1
C.2.3.4 Connectivity Options . . . . . . . . . . . . . . C-139
C.2.4 CommServer Configuration: The RRM Groups ScreensC-140
C.2.4.1 Configure New RRM Group . . . . . . . . . . C-142
C.2.4.2 The RRM Group Menu . . . . . . . . . . . . . C-149
C.2.4.3 Configure Existing RRM Group . . . . . . . . C-151
C.2.4.4 Configure New RRM . . . . . . . . . . . . . . C-153
C.2.4.5 Configure Existing RRM . . . . . . . . . . . . C-154
C.2.5 CommServer Configuration: Radio Link Features. . . C-160
C.2.7 Redundancy Options . . . . . . . . . . . . . . . . . . C-168
C.2.8 System Configuration: SNA Parameters . . . . . . . . C-172
C.2.9 System Configuration: The Users Screens . . . . . . . C-173
C.2.9.1 Create New User Entry . . . . . . . . . . . . . C-173
C.2.9.2 Edit Existing User Entry . . . . . . . . . . . . C-174
C.2.11 System Configuration: Miscellaneous System OptionsC-177
C.2.12 Miscellaneous Commands . . . . . . . . . . . . . . C-179
C.2.12.1 Display Entire Database Contents. . . . . . . C-179
C.2.12.2 Restart The CommServer Software . . . . . . C-180
C.2.12.3 Validate and Save Database Contents . . . . . C-181
C-2
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Introduction
C.1 Introduction
This guide describes all the screens accessible through the web interface of the Psion
Teklogix Communications Server.
C.1.1 About The 9500 CommServer’s Web Interface
The 9500 Communications Server presents a number of screens through a web interface. These include:
• Host application screens from 3274 and 5250 hosts.
See Section C.1.2 on page C-3.
• Configuration screens for the Psion Teklogix software.
See Section C.1.3 on page C-5.
These interfaces require that a connection using Internet Protocol (IP) be made to the
CommServer from another machine. A web browser can then be used to view screens and make changes.
C.1.2 The CommServer’s Host-Application Screens
To connect to the web-based host-application screens for the CommServer, direct a browser to:
http://<IP Address>:80/
where
IP Address
represents the CommServer’s IP address, and
80
is TCP Port 80, the standard port for HTTP connections.
C.1.2.1 The Host-Application Screens
The 9500 CommServer will only present host application screens as web pages if a
3274 or 5250 host is configured to use the HTML/HTTP protocol to send application screens to the terminal. This is selected in the Protocol Options screen for that host emulation. See the following pages:
•
For 3274 emulations, see page C-50.
•
For 5250 emulations, see page C-67.
Only 3274 and 5250 emulations may be configured to use this option.
Psion Teklogix 9500 Communications Server User Manual
C-3
Appendix C: The 9500 CommServer’s Web Interface
The CommServer’s Host-Application Screens
If no host application is configured to present screens through HTML/HTTP, the
CommServer displays the following screen to browsers connecting at port 80:
If one host application is configured to present screens through HTML/HTTP, the
CommServer briefly displays a redirect screen to browsers connecting at port 80, then displays the opening screen of the host application.
If a host application is present but misconfigured so that the CommServer cannot connect to the host, the CommServer displays the following screen:
If more than one host application is configured to present screens through
HTML/HTTP, the CommServer displays a choice screen to browsers connecting at port
80:
From this screen the user can choose the host to connect to. The CommServer then displays the first application screen for that host.
C-4
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
The CommServer’s Web Configuration Screens
C.1.2.2 Limitations Of The Host-Application Screens
Due in part to the nature of the HTTP protocol used by web browsers, these host screens suffer some limitations compared host screens transferred through TESS or ANSI protocols. In particular, the terminal’s browser must request new screens and updates; there is no way for the host to transfer information to the terminal without a request from the terminal.
These limitations include:
• Expedited messages, a break message, or screens that are sent by the host without prompting from the terminal will not be received by the web browser until the user sends data to the host (for example, by pressing the Refresh button or submitting the page).
• Web browsers receive a terminal ID from a pool. There is no way to map a terminal number to an IP or specific web browser session.
• By default the cursor mode is set to Insert and every time a new page is received the cursor mode is set to Insert. If there is pre-filled data in a field the
Insert key must be pressed to overwrite it.
• The function keys on the PC or terminal do not function as application function keys. The HTML function-key buttons provided at the bottom of the host application screen must be pressed to provide the proper function-key operation.
C.1.3 The CommServer’s Web Configuration Screens
To connect to the web-based configuration screens for the 9500 CommServer, direct a browser to:
http://<IP Address>:8008/
where
IP Address
represents the CommServer’s IP address, and
8008
is TCP Port
8008.
The CommServer’s web interface uses a number of the standard web control elements, such as text links, buttons and listboxes. In graphical browsers, these elements are manipulated using the cursor and a pointing device, such as a mouse; text-mode browsers may use different controls. Consult your browser documentation for details.
The following pictures present several of the CommServer’s web-interface screens as displayed by Netscape 4.03 running on a Windows 95 system. Each browser renders the parts of the screen in its own way; other browsers or other operating systems may appear somewhat different.
Psion Teklogix 9500 Communications Server User Manual
C-5
Appendix C: The 9500 CommServer’s Web Interface
The CommServer’s Web Configuration Screens
Figure C.1 A Browser Screen With Textboxes, Listboxes, Checkboxes And Buttons
This screen contains a selection of HTML elements used by the CommServer: textboxes, a listbox, checkboxes, and buttons.
HTML elements used by the CommServer are described below:
•
Text links:
When a text link is selected, the browser fetches another page from the CommServer. Text links are often shown in graphical browsers as coloured and underlined text, and they will be indicated in this manual as underlined text:
text link
•
Buttons:
When a button is selected, data is sent to the server to request another page. Buttons are often rendered to appear three-dimensional, so that they appear to move in and out when selected; this can be described as pressing the button. This manual indicates buttons as dark rectangles with white text:
Configure
C-6
Psion Teklogix 9500 Communications Server User Manual
•
Checkboxes:
Appendix C: The 9500 CommServer’s Web Interface
The CommServer’s Web Configuration Screens
A checkbox allows the user to select or deselect an item, independently of other items, similarly to checking off items on a list. The selected item is indicated by a dot, an X, a check mark , or some other mark filling the centre of the checkbox. Checkboxes are usually rendered by the browser as squares. This manual will indicate checkboxes as squares. Selected checkboxes are shown as squares containing checkmarks:
checkbox text checkbox text
•
Radiobuttons:
Like checkboxes, radiobuttons allow the user to select an item.
However, radiobuttons occur in groups, and they are mutu-
ally exclusive: when one of the buttons is selected, all of the other associated buttons are forcibly deselected. This mimics the action of push-button station selectors on oldfashioned car radios, hence the name. Radiobuttons are usually rendered by the browser as circular; this manual will indicate them as circles. Selected radiobuttons are indicated as circles containing dots:
Even None
•
Textboxes:
A textbox allows the user to type text into an area of the screen.
Some textboxes may contain default text. This manual indicates textboxes as rectangles:
•
Listboxes:
A listbox allows the user to select from among a number of choices.
An unselected listbox displays its default choice; when the listbox is selected, it
Psion Teklogix 9500 Communications Server User Manual
C-7
Appendix C: The 9500 CommServer’s Web Interface
The CommServer’s Web Configuration Screens
displays all of its choices and allows the user to choose from them. This manual indicates listboxes as rectangles with triangles:
Note:
Since these elements are rendered by the browser, their appearance will vary from one browser to another.
C.1.3.1 Items Common To Many Screens
There are a number of features common to many screens of the CommServer’s web interface. The most frequent of these are the OK, Cancel, and Main Menu buttons.
OK Button
OK
When the user presses the OK button after making changes in a screen, the CommServer accepts the changes, saves them to the temporary configuration cache, and displays a confirmation screen:
When the user presses the OK button on this screen, the CommServer displays the
Configuration Main Menu.
Notes:
1. From some screens the OK button causes the CommServer to display the
Hosts menu, the Base Stations menu, or the RRM Groups Menu.
From any of these menus, pressing the Main Menu button causes the
CommServer to display the Configuration Main Menu.
C-8
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
The CommServer’s Web Configuration Screens
2. To make changes permanent, validate them by pressing the Validate button on the CommServer’s Configuration Main Menu. The CommServer then checks the changes for errors. The changes may be saved by pressing the Commit button on the Database Validation Results screen.
Cancel Button
Cancel
This button discards any changes that have been made to the values in this screen and displays the Main Configuration screen.
Note:
From some screens this button may display the Hosts menu, the Base
Stations menu, the RRM Groups Menu, or the Database Backup menu. From any of these menus, pressing the Main Menu button causes the CommServer to display the Configuration Main Menu.
Main Menu Button
Main Menu
This button displays the Configuration Main Menu when it is pressed in the
Hosts Menu, the Base Stations Menu, the RRM Groups Menu, or the Database Backup
Menu.
C.1.3.2 Finding Screens
Two pages of maps starting on page C-12 show the relations of the various
screens of the 9500 Communications Server’s web interface.
Psion Teklogix 9500 Communications Server User Manual
C-9
Appendix C: The 9500 CommServer’s Web Interface
The CommServer’s Web Configuration Screens
In the lower right corner of each map is a screen key showing the arrangement of all of the CommServer’s Web screens on all of the map pages; the screen or screens referenced on that particular page are coloured black.
Screens on page 1 of the map
1
Screens on page 2 of the map
2
The screens referenced by this key
This key is also provided with the descriptions of the individual screens, following page
C-14. The individual screen is coloured black here.
Screens on page 1 of the map
1
2
Screens on page 2 of the map
The screen referenced by this key
In some places in the CommServer’s web interface, the user can choose an item from a listbox, then press a corresponding button.
The CommServer then displays a screen corresponding to the item in the list. The displayed screen is one of a number of related screens, one for each item in the list.
If the user can add new items to the list, there is a selection labeled appropriately in the listbox. Choosing this item and pressing the button opens a screen that allows the new item to be configured. In some cases, it is necessary to return to the main menu to configure additional properties for the new item.
In the example below, the Users listbox on the CommServer’s Configuration Main
Menu has a listbox containing the names of the users, along with a Create New selection. There are at least two screens accessible by pressing the Configure button.
C-10
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
The CommServer’s Web Configuration Screens
One screen, the New User screen, allows the addition of a new user.
The other screens, the User screens, give the details of the existing users. There is one
User screen for each user.
All of these screens, however, are represented as one in the screen key.
The Users listbox on the Configuration Main Menu:
[1] Create New
[1] Create New
[2] Sue
Configure
(the New User screen)
Set up new user
Change settings for user Sue
The screen key for the User and New User screens:
(a User screen)
1
2
Psion Teklogix 9500 Communications Server User Manual
C-11
Appendix C: The 9500 CommServer’s Web Interface
The CommServer’s Web Configuration Screens
C.1.3.3 Maps Of The CommServer’s Web Interface
9500 Communications Server:
Main
Configuration Screen
Controller Configuration
Hosts: Choose Configure
Base Stations:
Choose
Configure
RRM Groups:
Choose
Configure
Radio Link Features: Choose
802.IQ v1 And v2 Features:
Choose
Configure
Configure
Redundancy Configuration
Host Menu
General Options Configure
Emulation Options
Protocol Options
Configure
Configure
Function Key Mappings Configure
Main Menu
802.IQ v1 And v2 Features
OK Cancel
Radio Link Features
OK
Cancel Help
Function Key Mapping
OK
Cancel
Help
OK Cancel
Base Station Menu
General Options
Configure
Connectivity Options Configure
Main Menu
Protocol Options
OK
Cancel
Emulation Options
OK Cancel
RRM Groups Menu
General Options
RRMs
Choose
Configure
Configure
Analyze
Configure
Main Menu
OK
Connectivity Options
General Options
OK
Cancel
Analyse RRM Group
OK
Cancel Delete
1
Configure New or Existing RRM
OK Cancel
Delete
RRM Group Options
OK Cancel
OK
General Host Options
Cancel Delete
1
2
C-12
Psion Teklogix 9500 Communications Server User Manual
2
9500 Network Controller:
Main
Configuration Screen
Interface Configuration
Redundancy Configuration
Redundancy Options
Configure
SNA Protocol Configuration
System Management Parameters
Configure
System Configuration
Users Choose
Configure
SNMP Options
Choose
Configure
Miscellaneous System Options Choose
Configure
System Commands
Show Database Show All
Reboot Reboot
Validate and Save Database
Validate
Appendix C: The 9500 CommServer’s Web Interface
The CommServer’s Web Configuration Screens
Redundancy Options
OK Cancel
SNA Parameters
OK Cancel
Users
OK Cancel Delete
OK
SNMP Options
Cancel Delete
Miscellaneous Options
OK Cancel
Entire Database Contents
OK
Really Reboot?
OK
Cancel
Database Validation Results
Commit Undo Cancel
1
2
Psion Teklogix 9500 Communications Server User Manual
C-13
Appendix C: The 9500 CommServer’s Web Interface
The Web Configuration Screens
C.2 The Web Configuration Screens
In this section all the web configuration screens of the CommServer are presented.
C.2.1 The Configuration Main Menu Screen
1
2
The CommServer’s Configuration Main Menu screen is the first screen presented when the user connects to the CommServer. It is divided into five parts: Controller
Configuration, Redundancy Configuration, SNA Protocol Configuration, System
Configuration, and Miscellaneous Commands. These parts are described in the following sections.
C-14
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
The Configuration Main Menu Screen
C.2.1.1 Controller Configuration
From this part of the Configuration Main Menu, the links from the CommServer to hosts and to Psion Teklogix bases can be configured. There are four items in this section: Hosts, Base Stations, RRM Groups, and Radio-Link Features.
Hosts
The Hosts listbox allows the user to select a host connection. Choices include host connections already configured for this CommServer, and a special Create New choice.
Pressing the Configure button displays the configuration screen for the selected host connection. If Create New is selected, the user may choose a new host to add to the listbox; the new host connection can then be configured in the same way as previouslyexisting choices.
See “Controller Configuration: The Host Screens” on page C-19 for details.
Base Stations
The Base Stations listbox allows the user to select a base station connection. Choices include base station connections already configured for this CommServer, and a special
Create New choice.
Pressing the Configure button displays the configuration screen for the selected base station connection. If Create New is selected, the user may choose a new base station to add to the listbox; the new base station connection can then be configured in the same way as previously-existing choices.
See “CommServer Configuration: The Base Station Screens” on page C-132
for details.
RRM Groups
The RRM Groups listbox allows the user to select a group of RRMs. Choices include
RRM groups already configured for this CommServer, and a special Create New choice.
Psion Teklogix 9500 Communications Server User Manual
C-15
Appendix C: The 9500 CommServer’s Web Interface
The Configuration Main Menu Screen
Pressing the Configure button displays the configuration screen for the selected RRM group. If Create New is selected, the CommServer displays a configuration screen for the new RRM group. The user may choose RRMs to add to the new RRM group.
See “CommServer Configuration: The RRM Groups Screens” on page C-140
for details.
Radio-Link Features
Pressing the Radio-Link Features button displays a number of configuration options
802.IQ v1 And v2 Features
Pressing the 802.IQ v1 And v2 Features button displays a number of configuration
options related to the radio link. See “CommServer Configuration: 802.IQ v1 And v2
Features” on page C-165 for details.
C.2.1.2 Redundancy Configuration
This section of the Configuration Main Menu has only one item: Redundancy Options.
Redundancy Options
Pressing the Redundancy Options button displays the Redundancy Parameters screen.
Here are options for polling and communication between this CommServer, the backup
CommServer, and the network.
See “Redundancy Options” on page C-168 for details.
C.2.1.3 SNA Protocol Configuration
From this part of the Configuration Main Menu, options for SNA networking from the
CommServer to IBM hosts can be configured. There is one item in this section: System
Management Parameters.
C-16
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
The Configuration Main Menu Screen
System Management Parameters
Pressing the System Management Parameters button displays the SNA Parameters screen. From this screen, the user can set certain options for SNA including network name, local control point name, and exchange identifier.
See “System Configuration: SNA Parameters” on page C-172 for details.
C.2.1.4 System Configuration
From this part of the Configuration Main Menu, the user can set system-wide options for this CommServer. There are two items in this section: Users, and Miscellaneous
System Options.
Users
The Users listbox allows the user to select a user who is allowed to log in to this
CommServer. Choices include users who are already granted access to the
CommServer; there is also a special Create New choice.
Pressing the Configure button displays the configuration screen for the selected user. If
Add Entry is selected, the user may add a new user to the CommServer. An entry for the new user is added to the listbox; the new entry can then be configured in the same way as previously-existing entries.
See “System Configuration: The Users Screens” on page C-173 for details.
Miscellaneous System Options
Pressing the Miscellaneous System Options button displays the Miscellaneous System
Options screen. This screen contains settings for the CommServer’s serial number, and the maximum number of terminals allowed to connect to it.
See “System Configuration: Miscellaneous System Options” on page C-177
for details.
Psion Teklogix 9500 Communications Server User Manual
C-17
Appendix C: The 9500 CommServer’s Web Interface
The Configuration Main Menu Screen
C.2.1.5 Miscellaneous Commands
From this section, the user can check and save the CommServer’s configuration, or reboot the Psion Teklogix software in the CommServer.
Display Entire Database Contents
Pressing the Show All button causes the CommServer to display the entire contents of its configuration database.
See “Display Entire Database Contents” on page C-179 for details.
Restart Controller Software
Pressing the Restart button causes the CommServer to display a warning screen asking for confirmation of the request to restart. If confirmation is given to reboot, the
CommServer displays a last Restarting... screen, then is offline while it reboots.
See “Restart The CommServer Software” on page C-180 for details.
Validate And Save Current Configuration
Pressing the Validate button causes the CommServer to check the contents of its configuration cache, where recent changes are stored. The CommServer then displays a screen listing any errors, then offers the choice to commit to the new configuration, revert to the last saved configuration, or cancel and return to the main screen.
See “Validate and Save Database Contents” on page C-181 for details.
C-18
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
C.2.2 Controller Configuration: The Host Screens
Hosts listbox on Configuration Main Menu:
Configure
[1] Example Host
[#] Create New
[1] Example Host
Configure New Host
Host Menu
The host screens of the CommServer are accessible from the Hosts listbox and selection button.
C.2.2.1 Configure New Host
1
2
When the user chooses the Add Host selection host from the Hosts listbox and then presses the Configure button, the CommServer displays the Configure New Host screen.
In this screen, the user can set a name for, set an emulation and protocol for, and enable, a new host.
Psion Teklogix 9500 Communications Server User Manual
C-19
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
Protocols
Protocols are the methods by which terminals communicate with host computers. The
CommServer supports the TCP/IP and SNA protocols.
Protocols can operate over various physical media such as wired Ethernet or radio connections.
Emulations
Working with Psion Teklogix terminals and base stations, the CommServer can emulate
IBM model 3277, 3278-2, 5251-11, and 5555-B01 terminals, as well as ANSI terminals.
Only certain combinations of emulation and protocol are supported:
2392
3274
5250
ANSI
TCP/IP yes yes yes yes
SNA yes yes
Name Textbox
Name:
Values:
<any text string>
Default:
Unnamed Host
This textbox allows the user to enter a name for the new host.
Note:
The name must not contain space characters.
Enabled Checkbox
Enabled:
Values:
<selected>, <unselected>
Default:
<selected>
If this checkbox is selected, the CommServer will enable the connection to this host as it boots.
C-20
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
Emulation and Protocol Listbox
Emulation and Protocol:
Values:
Configure New, 3274/Telnet, 3274/SNA, 5250/Telnet,
5250/SNA, ANSI/Telnet, 9010/Telnet, 2392/Telnet,
RF Modem/Telnet, HTML, Remote Sockets
Default:
3274/Telnet
This listbox allows the user to select the emulation and protocol to be used for the connection to this host. Only certain combinations of emulation and protocol are available.
Terminal Range Textboxes
Terminal Range:
...
Values:
<see text>
Default:
1 ... 32
These textboxes allow the user to specify the range of terminals which will communicate with this host. The left-hand textbox contains the lowest terminal number which is allowed to communicate with the host; the right-hand textbox contains the highest terminal number.
Terminal numbers may range from 1 to 3840.
Note:
The Model S900L software-only version of the CommServer can handle a maximum of 50 terminals, so its highest terminal number is 50.
Psion Teklogix 9500 Communications Server User Manual
C-21
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
C.2.2.2 The Host Menu
1
2
When the user chooses an existing host from the Hosts listbox and then presses the
Configure button, the CommServer displays the Host Menu.
The Host Menu has four Configure buttons, which are located next to the following text:
• General Options
When the user presses this Configure button, the CommServer displays the
General Options screen for this host.
• Emulation Options
When the user presses this Configure button, the CommServer displays the
Emulation Options screen for this host. This screen varies depending on the type of emulation and protocol selected for the host.
C-22
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
• Protocol Options
When the user presses this Configure button, the CommServer displays the
Protocol Options screen for this host. This screen varies depending on the type of emulation and protocol selected for the host.
• Function Key Mappings
When the user presses this Configure button, the CommServer displays the
Function Key Mapping screen for this host. This screen varies depending on the type of emulation and protocol selected for the host.
There is also a Main Menu button. When the user presses this button, the CommServer displays the Configuration Main Menu.
C.2.2.3 General Host Options
1
2
In this screen, the user can select general options for this host connection. The host connection may also be deleted.
Protocols
Protocols are the methods by which terminals communicate with host computers. The
CommServer supports the TCP/IP and SNA protocols.
Psion Teklogix 9500 Communications Server User Manual
C-23
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
Protocols can operate over various physical media such as Ethernet, Token Ring, synchronous serial, and asynchronous serial connections, as well as wireless radio-link connections.
Emulations
Working with Psion Teklogix terminals and base stations, the CommServer can emulate
IBM model 3277, 3278-2, 5251-11, and 5555-B01 terminals, as well as ANSI terminals.
Only certain combinations of emulation and protocol are supported:
2392
3274
5250
ANSI
TCP/IP yes yes yes yes
SNA yes yes
Name Textbox
Name:
Values:
<any text string>
Default:
Unnamed Host
This textbox allows the user to enter a name for the host.
Note:
The name must not contain space characters.
Enabled Checkbox
Enabled:
Values:
<selected>, <unselected>
Default: <
selected>
If this checkbox is selected, the CommServer will enable the connection to this host as it boots.
C-24
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
Emulation and Protocol Listbox
Emulation and Protocol:
Values:
Configure New, 3274/Telnet, 3274/SNA, 5250/Telnet,
5250/SNA, ANSI/Telnet, 9010/Telnet, 2392/Telnet,
RF Modem/Telnet, HTML, Remote Sockets
Default:
3274/Telnet
This listbox allows the user to select the emulation and protocol to be used for the connection to this host. Only certain combinations of emulation and protocol are available.
Terminal Range Textboxes
Terminal Range:
...
Values:
<see text>
Default:
1 ... 32
These textboxes allow the user to specify the range of terminals which will communicate with this host. The left-hand textbox contains the lowest terminal number which is allowed to communicate with the host; the right-hand textbox contains the highest terminal number.
Terminal numbers may range from 1 to 3840.
Note:
The Model S900L software-only version of the CommServer can handle a maximum of 50 terminals, so its highest terminal number is 50.
Delete Button
Delete
The Delete button allows the user to delete the currently-displayed host connection.
When it is pressed, the CommServer displays a confirmation screen:
Psion Teklogix 9500 Communications Server User Manual
C-25
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
Note:
The screen shown here is the confirmation screen for deleting a host named Fred.
If the user presses the Cancel button on this screen, the CommServer displays the
Configure Host screen again. If the user presses the OK button, the CommServer removes the host connection’s data from the configuration cache and displays a confirmation screen:
When the user presses the OK button in this confirmation screen, the CommServer displays the Main Configuration screen again. The choice for the deleted host connection is no longer present in the Hosts listbox.
C.2.2.4 Emulation Options
This screen differs depending on the type of emulation and protocol selected in the
General Host Options screen. There are eight variants of this screen, one for each of the following emulation and protocol combinations:
•
ANSI emulation (telnet protocol). See page C-27.
• 2392 emulation (telnet protocol). See page C-33.
•
3274 emulation (telnet or TESS protocols). See page C-49.
•
5250 emulation (telnet or TESS protocols). See page C-65.
•
9010 emulation (telnet protocol). See page C-81.
•
RF Modem emulation (telnet protocol). See page C-82.
•
HTML emulation (TCP/IP protocol). See page C-83.
•
Remote Sockets emulation/protocol. See page C-87.
There are no configurable options for Remote Sockets.
C-26
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (ANSI Emulation)
The Emulation Options Screen (ANSI Emulation)
1
2
The CommServer displays this version of the Emulation Options screen after the user has selected the ANSI/Telnet emulation/protocol combination for this host connection.
Note:
The screen shown here gives the emulation options for a host named Gary.
Maximum Screen Size (rows x columns) Textboxes
Maximum Screen Size (rows x columns): x
Values:
rows 1 - 24, columns 1 - 80
Default:
24 x 80
Psion Teklogix 9500 Communications Server User Manual
C-27
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (ANSI Emulation)
These textboxes allow the user to specify the dimensions, in rows and columns, of the maximum terminal screen size.
Host Timeout Textbox
Host Timeout:
Values:
0 - 255
Default:
15
The host timeout is the interval (in 60ths of a second) between “bursts” of data received from the host.
If the CommServer does not receive any characters from the host after this timeout has elapsed, it assumes that the host has finished sending data and is waiting for user input
(in other words, it assumes that a screen of data has been completed).
Escape Timeout Textbox
Escape Timeout:
Values:
0 - 255
Default:
12
The escape timeout is the length of time (in 60ths of a second) that the CommServer will
“hang onto” an ESC received from the host, and consider the next received byte to be part of an escape sequence.
When this timeout has elapsed, the host will have to send another ESC character to start or continue an escape sequence.
Note:
This is especially important when an ESC is at the end of a data packet.
Threshold Textbox
Threshold:
Values:
0 - 999
Default:
200
This textbox allows the user to enter a threshold value for the selected ANSI host connection.
The threshold is the minimum number of bytes of update data for the terminal screen which must be received from the host before the CommServer will store the screen as a new “saved page”.
C-28
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (ANSI Emulation)
Important:
The Page parameter (see page 30) must be enabled in order to
change the value in the Threshold parameter.
Echo Checkbox
Echo:
Values:
<selected>, <unselected>
Default:
<selected>
If this checkbox is selected, the CommServer uses smart-echo.
Smart-echo reduces the amount of data sent to the terminal by decreasing the number of radio transmissions.
Ordinarily, when a character mode application is being used, each keystroke is sent to the host in one transmission, and the character is echoed by the host in another transmission.
When smart-echo is enabled, the CommServer will not send the host echo to the terminals if it matches the data sent from the terminal. Thus, the number of radio transmissions is reduced.
This mode also reduces or eliminates the delay between typing a character on the keyboard and displaying the character echoed by the host. The maximum number of characters waiting for echo is 25. Any additional characters will be sent to the host but not displayed.
Notes:
• Terminals with the proper software version will respond to this query; older terminals will ignore it.
• This parameter also determines whether an ANSI parameter query is sent to the terminal.
• Smart-echo also needs to be enabled at the terminal (refer to the appropriate terminal user manual).
Function Key Remapping Checkbox
Enabled:
Values:
<selected>, <unselected>
Default:
<unselected>
Psion Teklogix 9500 Communications Server User Manual
C-29
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (ANSI Emulation)
If this checkbox is selected, the CommServer remaps the function keys for this host connection as defined in the ANSI Function And Arrow Key Remappings screen. See
“Function Key Mapping” on page C-123.
Arrow Key Remapping Checkbox
Enabled:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer remaps the arrow keys for this host connection as defined in the ANSI Function And Arrow Key Remappings screen.See
“Function Key Mapping” on page C-123.
Page Checkbox
Enabled:
Values:
<selected>, <unselected>
Default:
<selected>
If this checkbox is selected, the CommServer uses page saving, reducing data transmitted to the terminals.
The CommServer maintains an image of each page stored at the terminal. After receiving an application screen, the CommServer tries to match the screen with a stored page. If the page is already in the terminal, the CommServer instructs the terminal to redisplay its stored copy of the page; no data need be sent across the radio link for that page. If the CommServer finds no match for the page, the complete page is sent to the terminal.
Note:
When page saving is enabled, the number of saved pages is that which is set on the terminal. Refer to the appropriate terminal user manual for details.
Page Saving Consider Double Byte Characters Checkbox
Page Saving consider Double Byte Characters:
Values:
<selected>, <unselected>
Default:
<unselected>
C-30
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (ANSI Emulation)
While using double byte character sets (for example, Chinese or Korean), the Page
Saving function can cause a double byte character to be partially overwritten. This can cause unprintable screen data and unintended characters; and may cause the terminal to shift data on the screen. Selecting this checkbox causes a double byte character half to be replaced with a space, preventing problems with terminal screen displays.
Select this checkbox only when using double byte character sets.
RLE Checkbox
Enabled:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer uses run-length encoding (RLE) on the data it sends across the radio link.
RLE compresses repeated characters going from the host to the terminal. If repeated characters are found in the data stream, the first one is sent, followed by a short escape sequence (3 or 4 characters) which tells the terminal how many times to repeat this character. In this way RLE compresses the data and decreases the total amount of radiolink traffic.
Convert 7 To 8 Bits Checkbox
Enabled:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer converts 7-bit control sequences to their
8-bin equivalents in ANSI datastreams going to the terminals. This replaces 7-bit twocharacter escape sequences with a single equivalent 8-bit character, compressing the data. For example, the escape sequence
ESC [
is converted to
CSI
.
Lower Character Set (GL) Listbox
Lower Character Set (GL):
Values:
<see text>
Default:
ASCII
This listbox allows the user to select the character set to be used for the first 128 character codes (decimal 0 to 127, hex 00 to 7F).
Psion Teklogix 9500 Communications Server User Manual
C-31
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (ANSI Emulation)
Available character sets include:
ASCII, DEC Multi, DEC Graphical, British DEC, Danish DEC, Dutch DEC, Finnish
DEC, French DEC, French CDN DEC, German DEC, Italian DEC, Portuagal DEC,
Spanish DEC, Swedish DEC, Swiss DEC, Arabic, Thai, and a Not Listed selection.
Upper Character Set (GR) Listbox
Upper Character Set (GR):
Values:
<see text>
Default:
DEC_Multi
This listbox allows the user to select the character set to be used for the second 128 character codes (decimal 128 to 255, hex 80 to FF).
Available character sets include:
ASCII, DEC Multi, DEC Graphical, British DEC, Danish DEC, Dutch DEC, Finnish
DEC, French DEC, French CDN DEC, German DEC, Italian DEC, Portuagal DEC,
Spanish DEC, Swedish DEC, Swiss DEC, Arabic, Thai, Latin 1, Latin 2, Latin 3, Latin
4, Latin 5, Latin 6, Cyrillic ISO, Arabic ISO, Greek ISO, Hebrew ISO, and Thai ISO.
C-32
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
The Emulation Options Screen (2392 Emulation)
1
2
Psion Teklogix 9500 Communications Server User Manual
C-33
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
The CommServer displays this version of the Emulation Options screen after the user has selected the 2392/Telnet emulation/protocol combination for the host connection.
Note:
The screen shown here gives the emulation options for a host named Elaine.
With HP 2392 emulation, the CommServer converts the application datastream from the host to TESS (TEklogix Screen Subsystem) commands. Some of the options in this screen govern this conversion of the host screens to TESS.
Send CR With FKEY Checkbox
Send CR with FKEY:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer sends a carriage-return after a functionkey.
Alarm Checkbox
Alarm:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, terminals will beep when the word ALARM (in capital letters) appears on the application screen, in the location specified by the “Command
Region” parameter (see page D-62). The word ALARM should be a display-only field.
Note:
The “Command Region” parameter must be enabled for this parameter to work.
Clear Checkbox
Clear:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer creates an empty entry field for an entry field that is filled with spaces.
C-34
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
Some host applications rely on the video attributes of displayed characters to highlight fields, particularly entry fields. For example, the application screen may define all entry fields with reverse video and fill the field with spaces. This is effective on terminals that support reverse video, but on terminals that do not, it can make the field invisible since it is made up entirely of spaces.
By default, all empty entry fields displayed at the Psion Teklogix terminal are highlighted by the “entry character” chosen in the terminal’s configuration (not all Psion
Teklogix terminals support video attributes). The Clear feature creates an empty entry field in place of an entry field filled with spaces.
Note:
This operation is only performed on screens received from the host. Data sent to the host remains unaffected.
Passthru Checkbox
Passthru:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer allows the host to send data directly to the
RF terminal’s serial port. This is most commonly used for printing.
Preparing Host Screens for Pass-Through
On the screen to be sent through the terminal serial port, the word PASSTHRU (in capital letters) has to appear on the first line, starting on the second column. The actual data to be sent to the terminal may start anywhere below the first line.
With 5250 or 3274 emulations, attributes occupy a position in the screen buffer. An attribute placed between column 2 and the end of the word “PASSTHRU” will ‘push’ all following characters one position to the right. Therefore, any required attributes should occupy column 1 of the first line (just preceding the word “PASSTHRU”).
For example:
column: 1 2 3 4 5 6 7 8 9
line 1: @ P A S S T H R U @ line 2: @ P A R T : 1 2 3 4 5
where
@
is an attribute.
Psion Teklogix 9500 Communications Server User Manual
C-35
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
When the CommServer is finished sending the data to the terminal’s printer, it will send an ENTER key to the host. The host must wait for the ENTER key before sending any more screens (including other PASSTHRU screens) to this terminal.
Note:
Refer to the Terminals User Manual for information about setting parameters on the terminal for pass-through.
Procedures Checkbox
Procedures:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer is allowed to send TESS procedures to the terminals. A TESS procedure is a group of TESS commands that can be executed by the
TESS execute procedure command.
Local Checkbox
Local:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer is allowed to provide pages to be loaded as local TESS procedures in the terminals.
The local procedures are selected from a menu at the terminal. The terminals can perform these procedures when they are offline. Later when the terminals are online, they send the results of these functions to the host.
Note:
The Procedures parameter also must be enabled for Local to work.
TSF/O Checkbox
TSF/O:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer uses Psion Teklogix’ Screen-
Formatter/Optimizer software.
C-36
Psion Teklogix 9500 Communications Server User Manual
8
9
10
11
12
13
14
15
1
2
3
4
5
6
7
16
17
18
19
20
21
22
23
24
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
Host Print Checkbox
Host Print:
Values:
<selected>, <unselected>
Default:
<unselected>
When this parameter is enabled, the host can send extra data to the terminal’s screens, and instruct the terminal to print it. This is in contrast to the Local Print feature, where the terminal makes the initial print request.
The text that is passed to the printer is formatted into the 24 x 80 application screen. If the host can initiate the print operation, the text is printed. The CommServer identifies the additional text as a print page by the presence of the word PRINT (in capital letters) beginning in the 2nd column of line 13 on the 24 x 80 screen. The word PRINT should be defined as display-only text.
The print page is positioned below the terminal’s display page (see the following figure). The size of the print page is always the same as the terminal’s display page
(assuming that in the terminal’s configuration, the page length is less than 12 lines).
When “Host Print” is enabled, the CommServer passes the print page to the terminal after receiving the application screen from the host.
Display Page (8 x 40)
Print Page (8 x 40)
Figure C.1 Application Screen With Print Page
Notes:
Psion Teklogix 9500 Communications Server User Manual
C-37
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
• Unlike with the “Passthru” option, when using “Host Print” no escape commands can be sent to the printer.
• Support for printing must be enabled at the terminal; refer to the appropriate terminal user manual for more information.
Remote Print Checkbox
Remote Print:
Values:
<selected>, <unselected>
Default:
<unselected>
When this parameter is enabled, the CommServer sends the print page to a terminal whenever the terminal requests it (by sending the F17 function key from the terminal, or the PRINT key on older terminals). The CommServer sends the function response back to the host.
This is in contrast to Host Print, where the host makes the initial print request.
Note:
Support for printing must be enabled at the terminal; refer to the appropriate terminal user manual for more information.
Pages Textbox
Pages:
Values:
0 - 79
Default:
8
The number of host screens (or pages) stored at the terminal.
The CommServer reduces data transmitted to the terminals by using the terminal’s capability to store a page of data for each screen it displays. The CommServer maintains an image of each page stored at the terminal. After receiving an application screen, the
CommServer tries to match the screen with a stored page.
If a similar page is already in the terminal’s memory, the CommServer simply instructs the terminal to re-display its copy of the page; only the necessary changes are sent from the CommServer. If no match is found, the complete page is sent to the terminal over the radio link.
Note:
There is a corresponding parameter on the terminal itself, and the actual number of saved pages will be the smaller of the two values.
C-38
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
Transmit Line Textbox
Transmit Line:
Values:
0 - 24
Default:
<none>
When this feature is enabled, all modified data at the terminal will be automatically transmitted when the operator enters data into a transmit-upon- entry field.
The value in this textbox specifies the line on the screen which is designated the
transmit line. The last entry field above or on the transmit line on the screen will be identified as the transmit-upon-entry field. If any entry fields exist on lines below the transmit line, no entry field will be designated as the transmit-upon-entry field.
A value of 0 (zero) disables this feature.
A value of 2 causes the last entry field on each application screen to be defined as
“transmit-upon-entry”.
AIAG Textbox
AIAG:
Values:
0 - 127
Default:
<none>
This textbox contains the decimal value of the ASCII character code of the AIAG mode
character as described below.
Whenever bar code data is entered at a terminal, the terminal searches for AIAG fields on the current page that can accept the bar code data. The data preloaded into the AIAG field by the application program determines whether the bar code data is accepted. The format of the preloaded data is:
<mode><AIAG prefix>
The application program distinguishes an entry field as AIAG by preceding the field with a special mode character which denotes the existence of AIAG fields on the host screen. This character is entered as an ASCII value.
Psion Teklogix 9500 Communications Server User Manual
C-39
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
The mode character is derived by starting with the decimal value 48 (ASCII character
‘0’) and adding the appropriate value from the table below.
Code Meaning of Code
1
Prevent the AIAG prefix from being displayed.
2
4
8
16
Prevent the AIAG prefix from being sent to the host.
Cause a transmission to the host when all AIAG fields with this mode set are filled.
The transmission is sent by a Function 0 (F0) code.
Allow overwriting of previously entered data.
Start the search for a matching AIAG field at the current cursor position. Otherwise, the cursor will start at the top of the page.
Table C.2 Mode values for the AIAG fields
For example, the ‘
@
’ symbol is used to apply the cursor matching function, since adding
16 to 48 results in decimal value 64, which is the ASCII value for the character ‘
@
’. A value of 0 (zero) disables this feature.
Visible Match Character Textbox
Visible Match Character:
Values:
0 - 127
Default:
<none>
With field matching, the host computer preloads data into an entry field. Now the terminal operator can make an entry that matches this preloaded data. For visible match fields, the preloaded data will be displayed in the entry field at the operator’s terminal.
The application program distinguishes an entry field as a match field by preceding it with a special character.
The special character is entered as the decimal character code for one of the first 127
ASCII characters.
A value of 0 (zero) disables this match field feature.
For example, assume that the “>” character (ASCII decimal character code 62) is defined for visible match fields. This character must immediately precede the entry field:
Part #
>
_______
C-40
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
The field:
Part #> includes the character > and is followed by the part number entry field on the screen. If any other character was chosen as the last character of the text, the entry field would not be a match field.
The preloaded data sent to a terminal may consist of the exact characters, special match characters or a combination of the two. The match characters recognized by the Psion
Teklogix terminals are shown in the table below.
For example, suppose you wish to preload an entry field with a part number. If the exact part number is known, you may simply preload the field with that part number. If more flexibility is required, and part numbers always begin with two alphabetic characters followed by a hyphen character and four digits, then the match string for the field could be:
&&–####
.
If an entry is different from the preloaded data, the entry will be displayed, the terminal will beep and the cursor will be in the first position of the match field.
Now either another entry in the match field can be made or the cursor can be moved to a new field. When an entry (even if it doesn’t match the host’s preloaded data) is made in a match field, this entry will be sent to the host as part of the terminal’s modified data during the next transmission.
Match Character Use
# match a number
&
^
_
|
"
?
'
:
; match a letter (either case) match an upper case letter match a lower case letter match an alphanumeric character match a letter, number or space match a punctuation character match any character match all character positions in the field with the preceding character match any remaining characters, but not necessarily the remainder of the field, with the preceding character
Psion Teklogix 9500 Communications Server User Manual
C-41
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
Table C.3 Match Characters
Hidden Match Character Textbox
Hidden Match Character:
Values:
0 - 127
Default:
<none>
A special character is used to mark Hidden Match fields in a TESS screen. This character precedes the field contents of the Hidden Match field. In hidden-match fields, as opposed to visible-match fields, the preloaded entry is not displayed in the entry field at the operator’s terminal).
This textbox allows the user to enter the decimal representation of the ASCII character code of this special character.
A value of 0 (zero) disables this feature.
Serial I/O Textbox
Serial I/O:
Values:
0 - 127
Default:
<none>
Serial I/O fields are special entry and fixed fields that accept input from and output to a serial port. The application program distinguishes this field as Serial I/O by preceding the field with a special character.
If this character precedes a fixed field, the data will be sent to the terminal’s serial port. If it precedes an entry field, the field accepts data from the terminal’s serial port.
This textbox contains the decimal representation of the ASCII character-code of this special character.
A value of 0 (zero) disables this feature.
Print Line Textbox
Print Line:
Values:
0 - 24
Default:
<none>
C-42
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
This textbox allows the user to enter the starting line number of the print page in the application screen.
A value of 1 (one) causes the display page to be printed. A value of 0 (zero) disables this feature.
Print Form Length Textbox
Print Line:
Values:
0 - 24
Default:
<none>
This textbox allows the user to enter the printer’s form length in lines.
Barcode Textbox
Barcode:
Values:
0-127
Default:
<none>
Barcode-input-only fields are special entry fields that only accept input from a bar code reader. The application program distinguishes an entry field as barcode-input-only by preceding the field with a special character.
This textbox contains the decimal representation of the ASCII character code of this special character.
A value of 0 (zero) disables this feature.
Entry Line Textbox
Entry Line:
Values:
0 - 24
Default:
<none>
This textbox contains the number of the first line displayed if there is no entry field in the upper-left portion of the screen and if an entry field is at or below this line.
The Entry Line parameter allows an automatic offset within the host screen, so that the area displayed by the terminal includes an entry field that would normally be out of bounds. Normally, Psion Teklogix terminals only display the upper left corner of the application screen because of their smaller display size.
Psion Teklogix 9500 Communications Server User Manual
C-43
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (2392 Emulation)
Field Overhead Textbox
Field Overhead:
Values:
0 - 80
Default:
5
This textbox contains the maximum number of characters allowed between two fixed fields which still allows the CommServer to join them into one field.
Sometimes the CommServer will join two adjacent fixed fields and then send them as one field. This reduces the overhead on the radio link.
For example, if two fields were 4 characters apart and this parameter was 5, then these fields would be joined into one.
This feature affects fields with the “Normal” display attribute only.
Command Region Textboxes
Command Region:
, ,
Values:
row values: 0-24; column values: 0-80
Default:
<none>
These two pairs of textboxes define a region of the host screen which the CommServer will examine for the presence of reserved commands. The first textbox of each pair contains the row number; the second contains the column number.
These four numbers represent the row and column addresses of the upper left corner and the lower right corner of the command region. To define the last two lines of the host screen as the command region, for example, enter the values 23, 1 and 24, 80.
Currently, the only commands supported in the command region are ALARM and
FONT:
• When the word ALARM is placed anywhere within the command region, the
CommServer will send a TESS beep command to the terminal.
• When the word FONT is placed anywhere within the command region, and followed by a number (the font code), the CommServer will send the appropriate TESS Change Font command to the terminal.
Psion Teklogix terminals use the font code to specify what font to use. See “Fonts And
Font Codes” on page E-45 for a listing of fonts and font codes.
C-44
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
Fonts And Font Codes
Fonts And Font Codes
Many Psion Teklogix terminals use a font code to specify what font to use. These font codes can be sent to the terminal by placing FONT, followed by the code, in the command region. The font code can be expressed as a decimal number or as a TESS representation of a decimal number.
When a valid FONT statement is found in the command region, the font code is stored with the page. When that page is sent to the terminal, an appropriate TESS Change Font command is also sent to the terminal, causing the terminal to use the specified font, if available.
The following font code table gives:
• the font code of each font,
• its size in pixels (width x height), and, for each terminal type:
• the number of rows displayed on the terminal,
• the number of characters (columns) in each row on that terminal.
If the font code is out of range it will cause a debug warning to be displayed and the command will be ignored. If the terminal debug level is level 4 or greater valid font change requests will be detailed.
Note:
See the TESS Manual for more details.
Psion Teklogix 9500 Communications Server User Manual
C-45
2
15
16
17
18
11
12
13
14
19
20
21
22
23
9
10
7
8
5
6
3
4
0
1
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
Fonts And Font Codes
Pixel Size
alias NORMAL alias SMALL alias LARGE alias TINY alias HUGE
5x8
6x8
7x8
8x8
8x16
8x19
16x32
8x12
6x12
10x24
16x24
12x20
10x12
12x12
16x12
16x20
16x25
8x18
16x16
Table C.4 Complete Font Code List
Row x Column Size
7035 8255VFD 8255LCD 8260/EL
loads median available font size * loads font with size nearest to halfway between NORMAL and TINY* loads font with size nearest to halfway between NORMAL and HUGE* loads smallest available font size* loads largest available font size*
18x32
18x26
10x51 25x128 60x128
10x42 25x106 60x106
18x20 historic (loads closest match)
10x32 25x80 60x80
9x20 ** 5x32 12x80 historic (loads closest match)
30x80 historic (loads closest match)
12x20 ** 6x32 16x80 40x80 historic (loads closest match) historic (loads closest match) historic (loads closest match)
7x13 ** 4x21 10x53 24x53
12x16 ** 6x25
12x13 ** 6x21
12x10 ** 6x16
7x10 ** 4x16
16x64
16x53
16x40
10x40
40x64
40x53
40x40
24x40
5x10 **
8x20
3x16
4x32
8x40
11x80 historic (loads closest match)
19x40
26x80
C-46
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
Fonts And Font Codes
24
32
33
34
26x26 Big 5 Chinese
**
16x16 Korean **
20x20
6x14
8x20 **
25
26
27
28
29
DBCS
11x17
16x30
10x21 Thai
12x32 Thai loads current DBCS font, or NORMAL if no DBCS font found
8x14 **
4x10 **
6x16
4x13 **
4x23
2x16
3x25
2x21
11x58
6x40
9x64
6x53
28x58
16x40
22x64
15x53
30 24x24 Korean ** 9x20 ** 5x32 ** 12x80 ** 25x80 **
31 16x16 Big 5 Chinese** 10x10 ** 5x16 ** 12x40 ** 25x40 **
10x10 **
7x8 **
10x26
4x32 **
5x16 **
4x12
5x42 **
11x80 ** 25x80 **
12x40 ** 25x40 **
10x32
14x106
**
24x32
34x106
**
35
16x16 Simplified
Chinese **
10x10 ** 5x16 ** 12x40 ** 25x40 **
36
37
38
39
40
41
5x12
8x14
20x29 Arabic
7x9
12x12 Korean **
12x32
10x20
- **
6x51 **
5x32 **
- **
16x128
**
- **
40x128
**
14x80 ** 34x80 **
- **
16x22 8x36 ** 22x91 ** 53x91 **
12x13 ** 6x21 ** 16x53 ** 40x53 **
13x13 ** 7x21 ** 18x53 ** 45x53 **
42
12x11 Korean **
12x12 Simplified
Chinese **
12x13 ** 6x21 ** 16x53 ** 40x53 **
43 12x12 Big 5 Chinese** 12x13 ** 6x21 ** 16x53 ** 40x53 **
44
24x24 Simplified
Chinese **
9x20 ** 5x32 ** 12x80 ** 25x80 **
Table C.4 Complete Font Code List
Psion Teklogix 9500 Communications Server User Manual
C-47
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
Fonts And Font Codes
* By default the aliases are set to:
2
3
0
1
4
Pixel Size
7035
Row x Column Size
8255VFD 8255LCD 8260/EL
alias NORMAL 18x32 (5) 10x32 (8) 25x80 (8) 30x80 (9) alias SMALL 18x32 (5) 10x42 (6) 25x80 (8) 30x80 (9) alias LARGE 10x26 (34) 10x32 (8) 11x80 (22) 26x80 (22) alias TINY 18x32 (5) 10x32 (8) 25x80 (8) 60x80 (8) alias HUGE 8x20 (22) 5x32 (9) 16x40 (19) 19x40 (21)
Table C.5 Default Font Aliases
** Not included in the international standard build.
C-48
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
The Emulation Options Screen (3274 Emulation)
1
2
Psion Teklogix 9500 Communications Server User Manual
C-49
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
The CommServer displays this version of the Emulation Options screen after the user has selected the 3274/Telnet or the 3274/TESS emulation/protocol combination for the host connection.
Note:
The screen shown here gives the emulation options for a host named Fred.
With IBM 3274, or IBM 5250 emulation, the CommServer converts the application datastream from the host to TESS (TEklogix Screen Subsystem) or HTML (HyperText
Markup language) data. Some of the options in this screen govern this conversion of the host screens to TESS or HTML.
Is Host Fujitsu Checkbox
Is Host Fujitsu:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer sends its data in Fujitsu format.
Enabling this parameter causes the standard IBM formatting codes (for start of field, setting buffers, etc.) to be replaced by the codes used by Fujitsu host computers.
Use International EBCDIC Checkbox
Use International EBCDIC:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer uses the ‘international’ EBCDIC character set, swapping the positions of the ! and ] characters.
Terminal Protocol Listbox
Terminal Protocol:
Values:
TESS/BCM, HTML/HTTP
Default:
TESS/BCM
This listbox allows the user to select the protocol to be used for the connection between the terminal and the CommServer. Terminals may connect through TESS or HTTP.
C-50
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
Connecting Through TESS
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
ANSI
TESS
PTX
Handler Software
PTX
Emulation
Software
PTX CommServer
Base
ANSI
Terminal
Software
TESS
Web
Browser
HTTP
Terminal
HTTP Server
Host Computer
Terminals connecting through TESS take advantage of the CommServer’s data-caching and page-saving software.
Connecting Through HTTP
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
PTX
Emulation
Software
Base
ANSI
Terminal
Software
TESS
Web
Browser
HTTP
Terminal
ANSI
TESS
PTX
Handler Software
PTX CommServer
HTTP Server
Host Computer
Terminals connecting through HTTP make use of an HTTP server in the CommServer.
The web browser on the terminal should be directed to the standard HTTP port (port 80) on the CommServer.
Psion Teklogix 9500 Communications Server User Manual
C-51
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
Alarm Checkbox
Alarm:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, terminals will beep when the word ALARM (in capital letters) appears on the application screen, in the location specified by the “Command
Region” parameter (see page D-62). The word ALARM should be a display-only field.
Note:
The “Command Region” parameter must be enabled for this parameter to work.
Clear Checkbox
Clear:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer creates an empty entry field for an entry field that is filled with spaces.
Some host applications rely on the video attributes of displayed characters to highlight fields, particularly entry fields. For example, the application screen may define all entry fields with reverse video and fill the field with spaces. This is effective on terminals that support reverse video, but on terminals that do not, it can make the field invisible since it is made up entirely of spaces.
By default, all empty entry fields displayed at the Psion Teklogix terminal are highlighted by the “entry character” chosen in the terminal’s configuration (not all Psion
Teklogix terminals support video attributes). The Clear feature creates an empty entry field in place of an entry field filled with spaces.
Note:
This operation is only performed on screens received from the host. Data sent to the host remains unaffected.
Passthru Checkbox
Passthru:
Values:
<selected>, <unselected>
Default:
<unselected>
C-52
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
If this checkbox is selected, the CommServer allows the host to send data directly to the
RF terminal’s serial port. This is most commonly used for printing.
Preparing Host Screens for Pass-Through
On the screen to be sent through the terminal serial port, the word PASSTHRU (in capital letters) has to appear on the first line, starting on the second column. The actual data to be sent to the terminal may start anywhere below the first line.
With 5250 or 3274 emulations, attributes occupy a position in the screen buffer. An attribute placed between column 2 and the end of the word “PASSTHRU” will ‘push’ all following characters one position to the right. Therefore, any required attributes should occupy column 1 of the first line (just preceding the word “PASSTHRU”).
For example:
column: 1 2 3 4 5 6 7 8 9
line 1: @ P A S S T H R U @ line 2: @ P A R T : 1 2 3 4 5
where
@
is an attribute.
When the CommServer is finished sending the data to the terminal’s printer, it will send an ENTER key to the host. The host must wait for the ENTER key before sending any more screens (including other PASSTHRU screens) to this terminal.
Note:
Refer to the Terminals User Manual for information about setting parameters on the terminal for pass-through.
Psion Teklogix 9500 Communications Server User Manual
C-53
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
Procedures Checkbox
Procedures:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer is allowed to send TESS procedures to the terminals. A TESS procedure is a group of TESS commands that can be executed by the
TESS execute procedure command.
Local Checkbox
Local:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer is allowed to provide pages to be loaded as local TESS procedures in the terminals.
The local procedures are selected from a menu at the terminal. The terminals can perform these procedures when they are offline. Later when the terminals are online, they send the results of these functions to the host.
Note:
The Procedures parameter also must be enabled for Local to work.
TSF/O Checkbox
TSF/O:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer uses Psion Teklogix’ Screen-
Formatter/Optimizer software.
Host Print Checkbox
Host Print:
Values:
<selected>, <unselected>
Default:
<unselected>
C-54
Psion Teklogix 9500 Communications Server User Manual
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
17
18
19
20
21
22
23
24
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
When this parameter is enabled, the host can send extra data to the terminal’s screens, and instruct the terminal to print it. This is in contrast to the Local Print feature, where the terminal makes the initial print request.
The text that is passed to the printer is formatted into the 24 x 80 application screen. If the host can initiate the print operation, the text is printed. The CommServer identifies the additional text as a print page by the presence of the word PRINT (in capital letters) beginning in the 2nd column of line 13 on the 24 x 80 screen. The word PRINT should be defined as display-only text.
The print page is positioned below the terminal’s display page (see the following figure). The size of the print page is always the same as the terminal’s display page
(assuming that in the terminal’s configuration, the page length is less than 12 lines).
When “Host Print” is enabled, the CommServer passes the print page to the terminal after receiving the application screen from the host.
Display Page (8 x 40)
Print Page (8 x 40)
Figure C.6 Application Screen With Print Page
Notes:
1. Unlike with the “Passthru” option, when using “Host Print” no escape commands can be sent to the printer.
2. Support for printing must be enabled at the terminal; refer to the appropriate terminal user manual for more information.
Psion Teklogix 9500 Communications Server User Manual
C-55
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
Remote Print Checkbox
Remote Print:
Values:
<selected>, <unselected>
Default:
<unselected>
When this parameter is enabled, the CommServer sends the print page to a terminal whenever the terminal requests it (by sending the F17 function key from the terminal, or the PRINT key on older terminals). The CommServer sends the function response back to the host.
This is in contrast to Host Print, where the host makes the initial print request.
Note:
Support for printing must be enabled at the terminal; refer to the appropriate terminal user manual for more information.
Pages Textbox
Pages:
Values:
0 - 79
Default:
8
The number of host screens (or pages) stored at the terminal.
The CommServer reduces data transmitted to the terminals by using the terminal’s capability to store a page of data for each screen it displays. The CommServer maintains an image of each page stored at the terminal. After receiving an application screen, the
CommServer tries to match the screen with a stored page.
If a similar page is already in the terminal’s memory, the CommServer simply instructs the terminal to re-display its copy of the page; only the necessary changes are sent from the CommServer. If no match is found, the complete page is sent to the terminal over the radio link.
Note:
There is a corresponding parameter on the terminal itself, and the actual number of saved pages will be the smaller of the two values.
C-56
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
Transmit Line Textbox
Transmit Line:
Values:
0 - 24
Default:
<none>
When this feature is enabled, all modified data at the terminal will be automatically transmitted when the operator enters data into a transmit-upon- entry field.
The value in this textbox specifies the line on the screen which is designated the
transmit line. The last entry field above or on the transmit line on the screen will be identified as the transmit-upon-entry field. If any entry fields exist on lines below the transmit line, no entry field will be designated as the transmit-upon-entry field.
A value of 0 (zero) disables this feature. A value of 2 causes the last entry field on each application screen to be defined as “transmit-upon-entry”.
AIAG Textbox
AIAG:
Values:
0 - 127
Default:
<none>
This textbox contains the decimal value of the ASCII character code of the AIAG mode
character as described below.
Whenever bar code data is entered at a terminal, the terminal searches for AIAG fields on the current page that can accept the bar code data. The data preloaded into the AIAG field by the application program determines whether the bar code data is accepted. The format of the preloaded data is:
<mode><AIAG prefix>
The application program distinguishes an entry field as AIAG by preceding the field with a special mode character which denotes the existence of AIAG fields on the host screen. This character is entered as an ASCII value.
Psion Teklogix 9500 Communications Server User Manual
C-57
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
The mode character is derived by starting with the decimal value 48 (ASCII character
‘0’) and adding the appropriate value from the table below.
Code Meaning of Code
1
Prevent the AIAG prefix from being displayed.
2
4
8
16
Prevent the AIAG prefix from being sent to the host.
Cause a transmission to the host when all AIAG fields with this mode set are filled.
The transmission is sent by a Function 0 (F0) code.
Allow overwriting of previously entered data.
Start the search for a matching AIAG field at the current cursor position. Otherwise, the cursor will start at the top of the page.
Table C.7 Mode values for the AIAG fields
For example, the ‘
@
’ symbol is used to apply the cursor matching function, since adding
16 to 48 results in decimal value 64, which is the ASCII value for the character ‘
@
’. A value of 0 (zero) disables this feature.
Visible Match Character Textbox
Visible Match Character:
Values:
0 - 127
Default:
<none>
With field matching, the host computer preloads data into an entry field. The terminal operator can make an entry that matches this preloaded data. For visible match fields, the preloaded data will be displayed in the entry field at the operator’s terminal.
The application program distinguishes an entry field as a match field by preceding it with a special character. The special character is entered as the decimal character code for one of the first 127 ASCII characters.
An entered value of 0 (zero) disables this match field feature.
For example, assume that the “>” character (ASCII decimal character code 62) is defined for visible match fields. This character must immediately precede the entry field:
Part #
>
_______
C-58
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
The field:
Part #> includes the character > and is followed by the part number entry field on the screen. If any other character was chosen as the last character of the text, the entry field would not be a match field.
The preloaded data sent to a terminal may consist of the exact characters, special match characters or a combination of the two. The match characters recognized by the Psion
Teklogix terminals are shown in the table below.
For example, suppose you wish to preload an entry field with a part number. If the exact part number is known, you may simply preload the field with that part number. If more flexibility is required, and part numbers always begin with two alphabetic characters followed by a hyphen character and four digits, then the match string for the field could be:
&&–####
.
If an entry is different from the preloaded data, the entry will be displayed, the terminal will beep and the cursor will be in the first position of the match field.
Now either another entry in the match field can be made or the cursor can be moved to a new field. When an entry (even if it doesn’t match the host’s preloaded data) is made in a match field, this entry will be sent to the host as part of the terminal’s modified data during the next transmission.
Match Character Use
# match a number
&
^
_
|
"
?
'
:
; match a letter (either case) match an upper case letter match a lower case letter match an alphanumeric character match a letter, number or space match a punctuation character match any character match all character positions in the field with the preceding character match any remaining characters, but not necessarily the remainder of the field, with the preceding character
Table C.8 Match Characters
Psion Teklogix 9500 Communications Server User Manual
C-59
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
Hidden Match Character Textbox
Hidden Match Character:
Values:
0 - 127
Default:
<none>
A special character is used to mark Hidden Match fields in a TESS screen. This character precedes the field contents of the Hidden Match field. In hidden-match fields, as opposed to visible-match fields, the preloaded entry is not displayed in the entry field at the operator’s terminal).
This textbox allows the user to enter the decimal representation of the ASCII character code of this special character.
A value of 0 (zero) disables this feature.
Serial I/O Textbox
Serial I/O:
Values:
0 - 127
Default:
<none>
Serial I/O fields are special entry and fixed fields that accept input from and output to a serial port. The application program distinguishes this field as Serial I/O by preceding the field with a special character.
If this character precedes a fixed field, the data will be sent to the terminal’s serial port. If it precedes an entry field, the field accepts data from the terminal’s serial port.
This textbox contains the decimal representation of the ASCII character-code of this special character. A value of 0 (zero) disables this feature.
Print Line Textbox
Print Line:
Values:
0 - 24
Default:
<none>
This textbox allows the user to enter the starting line number of the print page in the application screen.
C-60
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
A value of 1 (one) causes the display page to be printed. A value of 0 (zero) disables this feature.
Print Form Length Textbox
Print Line:
Values:
0 - 24
Default:
<none>
This textbox allows the user to enter the printer’s form length in lines.
Barcode Textbox
Barcode:
Values:
0-127
Default:
<none>
Barcode-input-only fields are special entry fields that only accept input from a bar code reader. The application program distinguishes an entry field as barcode-input-only by preceding the field with a special character.
This textbox contains the decimal representation of the ASCII character code of this special character.
A value of 0 (zero) disables this feature.
Entry Line Textbox
Entry Line:
Values:
0 - 24
Default:
<none>
This textbox contains the number of the first line displayed if there is no entry field in the upper-left portion of the screen and if an entry field is at or below this line.
The Entry Line parameter allows an automatic offset within the host screen, so that the area displayed by the terminal includes an entry field that would normally be out of bounds. Normally, Psion Teklogix terminals only display the upper left corner of the application screen because of their smaller display size.
Psion Teklogix 9500 Communications Server User Manual
C-61
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
Field Overhead Textbox
Field Overhead:
Values:
0 - 80
Default:
5
This textbox contains the maximum number of characters allowed between two fixed fields which still allows the CommServer to join them into one field.
Sometimes the CommServer will join two adjacent fixed fields and then send them as one field. This reduces the overhead on the radio link.
For example, if two fields were 4 characters apart and this parameter was 5, then these fields would be joined into one.
This feature affects fields with the “Normal” display attribute only.
Command Region Textboxes
Command Region:
, ,
Values:
row values: 0-24; column values: 0-80
Default:
<none>
These two pairs of textboxes define a region of the host screen which the CommServer will examine for the presence of reserved commands. The first textbox of each pair contains the row number; the second contains the column number.
These four numbers represent the row and column addresses of the upper left corner and the lower right corner of the command region. To define the last two lines of the host screen as the command region, for example, enter the values 23, 1 and 24, 80.
Currently, the only commands supported in the command region are ALARM and FONT:
• When the word ALARM is placed anywhere within the command region, the
CommServer will send a TESS beep command to the terminal.
• When the word FONT is placed anywhere within the command region, and followed by a number (the font code), the CommServer will send the appropriate TESS Change Font command to the terminal.
Psion Teklogix terminals use the font code to specify what font to use. See “Fonts And
Font Codes” on page E-45 for a listing of fonts and font codes.
C-62
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
Foreground Colour Listbox
Foreground Colour:
Values:
Aqua, Black, Blue, Fuschia, Gray, Green, Lime,
Maroon, Navy, Olive, Purple, Red, Silver, Teal,
White, Yellow
Default:
Black
This listbox allows the user to select the ‘foreground colour’, the colour of the text, that the CommServer’s HTTP server will send to terminals connecting via HTTP. The choices are the 16 predefined HTML colour names.
Background Colour Listbox
Background Colour:
Values:
Aqua, Black, Blue, Fuschia, Gray, Green, Lime,
Maroon, Navy, Olive, Purple, Red, Silver, Teal,
White, Yellow
Default:
Silver
This listbox allows the user to select the ‘background colour’, the colour of the HTML page, that the CommServer’s HTTP server will send to terminals connecting via HTTP.
The choices are the 16 predefined HTML colour names.
User Data Font Size Listbox
User Data Font Size:
Values:
1, 2, 3, 4, 5, 6, 7
Default:
3
This listbox allows the user to select the size of the font in which user data will be presented to the terminals’web browser.
Function Key Font Size Listbox
Function Key Font Size:
Values:
4pt, 6pt, 8pt, 10pt, 12pt, 14pt
Default:
8pt
Psion Teklogix 9500 Communications Server User Manual
C-63
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (3274 Emulation)
This listbox allows the user to select the protocol to be used for the connection between the terminal and the CommServer. Terminals may connect through TESS or HTTP.
TSF/O Checkbox
TSF/O:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer uses Psion Teklogix’ Screen-
Formatter/Optimizer software.
C-64
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
The Emulation Options Screen (5250 Emulation)
1
2
Psion Teklogix 9500 Communications Server User Manual
C-65
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
The CommServer displays this version of the Emulation Options screen after the user has selected the 5250/Telnet or 5250/TESS emulation/protocol combinations for this host connection.
Note:
The screen shown here gives the emulation options for a host named Fred.
With IBM 3274, or IBM 5250 emulation, the CommServer converts the application datastream from the host to TESS (TEklogix Screen Subsystem) or HTML (HyperText
Markup language) data. Some of the options in this screen govern this conversion of the host screens to TESS or HTML.
Write Error Code Listbox
Write Error Code:
Values:
advisory text, screen text
Default:
advisory text
If advisory text is selected here, the CommServer sends error codes to the terminal screen as advisory text, which is written at the bottom of the screen. If screen text is chosen, the CommServer sends the error codes as regular screen text.
Field Underline Remapping Listbox
Field Underline Remapping:
Values:
None, Blink, Bold, Reverse
Default:
None
This listbox allows the user to select how the CommServer renders underlined fields sent from the host.
Use International EBCDIC Checkbox
Use International EBCDIC:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer will swap the positions of the ! and ] characters in the EBCDIC character table.
C-66
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
Terminal Protocol Listbox
Terminal Protocol:
Values:
TESS/BCM, HTML/HTTP
Default:
TESS/BCM
This listbox allows the user to select the protocol to be used for the connection between the terminal and the CommServer. Terminals may connect through TESS or HTTP.
Connecting Through TESS
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
ANSI
TESS
PTX
Handler Software
PTX
Emulation
Software
PTX CommServer
Base
ANSI
Terminal
Software
TESS
Web
Browser
HTTP
Terminal
HTTP Server
Host Computer
Terminals connecting through TESS take advantage of the CommServer’s data-caching and page-saving software.
Psion Teklogix 9500 Communications Server User Manual
C-67
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
Connecting Through HTTP
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
PTX
Emulation
Software
ANSI
TESS
PTX
Handler Software
PTX CommServer
Base
ANSI
Terminal
Software
TESS
Web
Browser
HTTP
Terminal
HTTP Server
Host Computer
Terminals connectig through HTTP make use of an HTTP server in the CommServer’s emulation software. The web browser on the terminal should be directed to the standard
HTTP port (port 80) on the CommServer.
Alarm Checkbox
Alarm:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, terminals will beep when the word ALARM (in capital letters) appears on the application screen, in the location specified by the “Command
Region” parameter (see page C-62). The word ALARM should be a display-only field.
Note:
The “Command Region” parameter must be enabled for this parameter to work.
C-68
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
Clear Checkbox
Clear:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer creates an empty entry field for an entry field that is filled with spaces.
Some host applications rely on the video attributes of displayed characters to highlight fields, particularly entry fields. For example, the application screen may define all entry fields with reverse video and fill the field with spaces. This is effective on terminals that support reverse video, but on terminals that do not, it can make the field invisible since it is made up entirely of spaces.
By default, all empty entry fields displayed at the Psion Teklogix terminal are highlighted by the “entry character” chosen in the terminal’s configuration (not all Psion
Teklogix terminals support video attributes). The Clear feature creates an empty entry field in place of an entry field filled with spaces.
Note:
This operation is only performed on screens received from the host. Data sent to the host remains unaffected.
Passthru Checkbox
Passthru:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer allows the host to send data directly to the
RF terminal’s serial port. This is most commonly used for printing.
Preparing Host Screens for Pass-Through
On the screen to be sent through the terminal serial port, the word PASSTHRU (in capital letters) must appear on the first line, starting on the second column. The actual data to be sent to the terminal may start anywhere below the first line.
With 5250 or 3274 emulations, attributes occupy a position in the screen buffer. An attribute placed between column 2 and the end of the word “PASSTHRU” will ‘push’ all following characters one position to the right. Therefore, any required attributes should occupy column 1 of the first line (just preceding the word “PASSTHRU”).
Psion Teklogix 9500 Communications Server User Manual
C-69
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
For example:
column: 1 2 3 4 5 6 7 8 9
line 1: @ P A S S T H R U @
line 2: @ P A R T : 1 2 3 4 5
where
@
is an attribute.
When the CommServer is finished sending the data to the terminal’s printer, it will send an ENTER key to the host. The host must wait for the ENTER key before sending any more screens (including other PASSTHRU screens) to this terminal.
Note:
Refer to the appropriate terminal user manual for information about setting parameters on the terminal for pass-through.
Procedures Checkbox
Procedures:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer is allowed to send TESS procedures to the terminals. A TESS procedure is a group of TESS commands that can be executed by the
TESS execute procedure command.
Local Checkbox
Local:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer is allowed to provide pages to be loaded as local TESS procedures in the terminals.
The local procedures are selected from a menu at the terminal. The terminals can perform these procedures when they are offline. Later when the terminals are online, they send the results of these functions to the host.
Note:
The Procedures parameter also must be enabled for Local to work.
C-70
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
TSF/O Checkbox
TSF/O:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer uses Psion Teklogix’ Screen-
Formatter/Optimizer software.
Host Print Checkbox
Host Print:
Values:
<selected>, <unselected>
Default:
<unselected>
When this parameter is enabled, the host can send extra data to the terminal’s screens, and instruct the terminal to print it. This is in contrast to the Local Print feature, where the terminal makes the initial print request.
The text that is passed to the printer is formatted into the 24 x 80 application screen. If the host can initiate the print operation, the text is printed. The CommServer identifies the additional text as a print page by the presence of the word PRINT (in capital letters) beginning in the 2nd column of line 13 on the 24 x 80 screen. The word PRINT should be defined as display-only text.
The print page is positioned below the terminal’s display page (see the following figure). The size of the print page is always the same as the terminal’s display page
(assuming that in the terminal’s configuration, the page length is less than 12 lines).
When “Host Print” is enabled, the CommServer passes the print page to the terminal after receiving the application screen from the host.
Psion Teklogix 9500 Communications Server User Manual
C-71
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
17
18
19
20
21
22
23
24
Display Page (8 x 40)
Print Page (8 x 40)
Figure C.9 Application Screen With Print Page
Notes:
• Unlike with the “Passthru” option, when using “Host Print” no escape commands can be sent to the printer.
• Support for printing must be enabled at the terminal level – refer to the
Terminals User Manual or the Parameter Guide for more information).
Remote Print Checkbox
Remote Print:
Values:
<selected>, <unselected>
Default:
<unselected>
When this parameter is enabled, the CommServer sends the print page to a terminal whenever the terminal requests it (by sending the F17 function key from the terminal, or the PRINT key on older terminals). The CommServer sends the function response back to the host.
This is in contrast to Host Print, where the host makes the initial print request.
Note:
Support for printing must be enabled at the terminal level. Refer to the appropriate terminal user manual for more information.
C-72
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
Pages Textbox
Pages:
Values:
0 - 79
Default:
8
The number of host screens (or pages) stored at the terminal.
The CommServer reduces data transmitted to the terminals by using the terminal’s capability to store a page of data for each screen it displays. The CommServer maintains an image of each page stored at the terminal. After receiving an application screen, the
CommServer tries to match the screen with a stored page.
If a similar page is already in the terminal’s memory, the CommServer simply instructs the terminal to re-display its copy of the page; only the necessary changes are sent from the CommServer. If no match is found, the complete page is sent to the terminal over the radio link.
Note:
There is a corresponding parameter on the terminal itself, and the actual number of saved pages will be the smaller of the two values.
Transmit Line Textbox
Transmit Line:
Values:
0 - 24
Default:
<none>
When this feature is enabled, all modified data at the terminal will be automatically transmitted when the operator enters data into a transmit-upon- entry field.
The value in this textbox specifies the line on the screen which is designated the
transmit line. The last entry field above or on the transmit line on the screen will be identified as the transmit-upon-entry field. If any entry fields exist on lines below the transmit line, no entry field will be designated as the transmit-upon-entry field.
A value of 0 (zero) disables this feature.
A value of 24 will cause the last entry field on each application screen to be defined as
“transmit-upon-entry”.
Psion Teklogix 9500 Communications Server User Manual
C-73
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
AIAG Textbox
AIAG:
Values:
0 - 127
Default:
<none>
This textbox contains the decimal value of the ASCII character code of the AIAG mode
character as described below.
Whenever bar code data is entered at a terminal, the terminal searches for AIAG fields on the current page that can accept the bar code data. The data preloaded into the AIAG field by the application program determines whether the bar code data is accepted. The format of the preloaded data is:
<mode><AIAG prefix>
The application program distinguishes an entry field as AIAG by preceding the field with a special mode character which denotes the existence of AIAG fields on the host screen. This character is entered as an ASCII value.
The mode character is derived by starting with the decimal value 48 (ASCII character
‘0’) and adding the appropriate value from the table below.
Code Meaning of Code
1
Prevent the AIAG prefix from being displayed.
2
4
8
16
Prevent the AIAG prefix from being sent to the host.
Cause a transmission to the host when all AIAG fields with this mode set are filled.
The transmission is sent by a Function 0 (F0) code.
Allow overwriting of previously entered data.
Start the search for a matching AIAG field at the current cursor position.
Otherwise, the cursor will start at the top of the page.
Table C.10 Mode values for the AIAG fields
For example, the ‘
@
’ symbol is used to apply the cursor matching function, since adding
16 to 48 results in decimal value 64, which is the ASCII value for the character ‘
@
’.
A value of 0 (zero) disables this feature.
C-74
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
Visible Match Character Textbox
Visible Match Character:
Values:
0 - 127
Default:
<none>
With field matching, the host computer preloads data into an entry field. Now the terminal operator can make an entry that matches this preloaded data. For visible match fields, the preloaded data will be displayed in the entry field at the operator’s terminal.
The application program distinguishes an entry field as a match field by preceding it with a special character.
The special character is entered as the decimal character code for one of the first 127
ASCII characters.
A value of 0 (zero) disables this match field feature.
For example, assume that the “>” character (ASCII decimal character code 62) is defined for visible match fields. This character must immediately precede the entry field:
Part #
>
_______
The field:
Part #> includes the character > and is followed by the part number entry field on the screen. If any other character was chosen as the last character of the text, the entry field would not be a match field.
The preloaded data sent to a terminal may consist of the exact characters, special match characters or a combination of the two. The match characters recognized by the Psion
Teklogix terminals are shown in the table below.
For example, suppose you wish to preload an entry field with a part number. If the exact part number is known, you may simply preload the field with that part number. If more flexibility is required, and part numbers always begin with two alphabetic characters followed by a hyphen character and four digits, then the match string for the field could be:
&&–####
.
If an entry is different from the preloaded data, the entry will be displayed, the terminal will beep and the cursor will be in the first position of the match field.
Psion Teklogix 9500 Communications Server User Manual
C-75
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
Now either another entry in the match field can be made or the cursor can be moved to a new field. When an entry (even if it doesn’t match the host’s preloaded data) is made in a match field, this entry will be sent to the host as part of the terminal’s modified data during the next transmission.
Match Character Use
#
& match a number match a letter (either case)
^
_
|
"
?
'
:
; match an upper case letter match a lower case letter match an alphanumeric character match a letter, number or space match a punctuation character match any character match all character positions in the field with the preceding character match any remaining characters, but not necessarily the remainder of the field, with the preceding character
Table C.11 Match Characters
Hidden Match Character Textbox
Hidden Match Character:
Values:
0 - 127
Default:
<none>
A special character is used to mark Hidden Match fields in a TESS screen. This character precedes the field contents of the Hidden Match field. In hidden-match fields, as opposed to visible-match fields, the preloaded entry is not displayed in the entry field at the operator’s terminal).
This textbox allows the user to enter the decimal representation of the ASCII character code of this special character. A value of 0 (zero) disables this feature.
C-76
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
Serial I/O Textbox
Serial I/O:
Values:
0 - 127
Default:
<none>
Serial I/O fields are special entry and fixed fields that accept input from and output to a serial port. The application program distinguishes this field as Serial I/O by preceding the field with a special character.
If this character precedes a fixed field, the data will be sent to the terminal’s serial port. If it precedes an entry field, the field accepts data
from the terminal’s serial port.
This textbox contains the decimal representation of the ASCII character-code of this special character.
A value of 0 (zero) disables this feature.
Print Line Textbox
Print Line:
Values:
0 - 24
Default:
<none>
This textbox allows the user to enter the starting line number of the print page in the application screen.
A value of 1 causes the display page to be printed. A value of 0 (zero) disables this feature.
Print Form Length Textbox
Print Line:
Values:
0 - 24
Default:
<none>
This textbox allows the user to enter the printer’s form length in lines.
Psion Teklogix 9500 Communications Server User Manual
C-77
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
Barcode Textbox
Barcode:
Values:
0 - 127
Default:
<none>
Barcode-input-only fields are special entry fields that only accept input from a bar code reader. The application program distinguishes an entry field as barcode-input-only by preceding the field with a special character.
This textbox contains the decimal representation of the ASCII character code of this special character.
A value of 0 (zero) disables this feature.
Entry Line Textbox
Entry Line:
Values:
0 - 24
Default:
<none>
This textbox contains the number of the first line displayed if there is no entry field in the upper left portion of the screen and if an entry field is at or below this line.
The Entry Line parameter allows an automatic offset within the host screen, so that the area displayed by the terminal includes an entry field that would normally be out of bounds. Normally, Psion Teklogix terminals only display the upper left corner of the application screen because of their smaller display size.
Field Overhead Textbox
Field Overhead:
Values:
0 - 80
Default:
0
This textbox contains the maximum number of characters allowed between two fixed fields which still allows the CommServer to join them into one field.
Sometimes the CommServer will join two adjacent fixed fields and then send them as one field. This reduces the overhead on the radio link. For example, if two fields were 4 characters apart and this parameter was 5, then these fields would be joined into one.
This feature affects fields with the “Normal” display attribute only.
C-78
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
Command Region Textboxes
Command Region: , -
,
Values:
row values: 0-24; column values: 0-80
Default:
<none>
These two pairs of textboxes define a region of the host screen which the CommServer will examine for the presence of reserved commands. The first textbox of each pair contains the row number; the second contains the column number.
These four numbers represent the row and column addresses of the upper left corner and the lower right corner of the command region. To define the last two lines of the host screen as the command region, for example, enter the values 23, 1 and 24, 80.
Currently, the only commands supported in the command region are ALARM and
FONT:
• When the word ALARM is placed anywhere within the command region, the
CommServer will send a TESS beep command to the terminal.
• When the word FONT is placed anywhere within the command region, and followed by a number (the font code), the CommServer will send the appropriate TESS Change Font command to the terminal.
Psion Teklogix terminals use the font code to specify what font to use. See “Fonts And
Font Codes” on page E-45 for a listing of fonts and font codes.
Enable Colour Support Checkbox
Enable Colour Support:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer uses coloured text in the host screens it sends to the terminals.
Foreground Colour Listbox
Foreground Colour:
Values:
Aqua, Black, Blue, Fuschia, Gray, Green, Lime,
Maroon, Navy, Olive, Purple, Red, Silver, Teal,
White, Yellow
Psion Teklogix 9500 Communications Server User Manual
C-79
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (5250 Emulation)
Default:
Black
This listbox allows the user to select the ‘foreground colour’, the colour of the text, that the CommServer’s HTTP server will send to terminals connecting via HTTP. The choices are the 16 predefined HTML colour names.
Background Colour Listbox
Background Colour:
Values:
Aqua, Black, Blue, Fuschia, Gray, Green, Lime,
Maroon, Navy, Olive, Purple, Red, Silver, Teal,
White, Yellow
Default:
Silver
This listbox allows the user to select the ‘background colour’, the colour of the HTML page, that the CommServer’s HTTP server will send to terminals connecting via HTTP.
The choices are the 16 predefined HTML colour names.
User Data Font Size Listbox
User Data Font Size:
Values:
1, 2, 3, 4, 5, 6, 7
Default:
3
This listbox allows the user to select the size of the font in which user data will be presented to the terminals’web browser.
Function Key Font Size Listbox
Function Key Font Size:
Values:
4pt, 6pt, 8pt, 10pt, 12pt, 14pt
Default:
8pt
This listbox allows the user to select the protocol to be used for the connection between the terminal and the CommServer. Terminals may connect through TESS or HTTP.
TSF/O Checkbox
TSF/O:
Values:
<selected>, <unselected>
C-80
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (9010 Emulation)
Default:
<unselected>
If this checkbox is selected, the CommServer uses Psion Teklogix’ Screen-
Formatter/Optimizer software.
The Emulation Options Screen (9010 Emulation)
1
2
The CommServer displays this version of the Emulation Options screen after the user has selected the 9010/Telnet or 9010/Serial emulation/protocol combinations for this host connection.
Note:
The screen shown here gives the emulation options for a host named Cecil.
Refrain From Sending Online & Offline Messages Checkbox
Refrain from sending Online & Offline messages:
Values:
<enabled>, <disabled>
Default:
<disabled>
If this checkbox is enabled, the CommServer does not send terminal-offline and terminal-online messages to the host.
Psion Teklogix 9500 Communications Server User Manual
C-81
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (RF Modem Emulation)
The Emulation Options Screen (RF Modem Emulation)
1
2
The CommServer displays this version of the Emulation Options screen after the user has selected the RF Modem/Telnet emulation/protocol combinations for this host connection.
Note:
The screen shown here gives the emulation options for a host named Greg.
This emulation is intended for a CommServer communicating with a Psion Teklogix
Model 6040 RF Modem; since the 6040 simply passes serial data through to connected serial devices, there are no emulation options.
C-82
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (HTML Emulation)
The Emulation Options Screen (HTML Emulation)
1
2
The CommServer displays this version of the Emulation Options screen after the user has selected the HTML emulation/protocol combinations for this host connection.
Note:
The screen shown here gives the emulation options for a host named Aline.
This emulation is intended for a CommServer interpreting HTML pages for terminals running TESS. The CommServer transforms TESS requests to from the terminals into standard HTML requests, and sends the HTML requests to a server. Replies from the web server arrive in the form of HTML pages; the CommServer translates these into equivalent TESS pages and sends them on to the terminals.
Psion Teklogix DOS-based terminals communicating by TCP/IP to access points do not require this emulation.
Psion Teklogix 9500 Communications Server User Manual
C-83
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (HTML Emulation)
Screen Size Textboxes
Screen Size: x
Values:
1 x 1 - 40 x 132
Default:
24 x 80
These textboxes contain the number of lines on the terminal screen, and the number of characters in each line.
If you enter an invalid range, an error message results. Changes are not written to the database, and you can enter a valid range.
Start Page Textbox
Start Page:
Values:
<any valid web address>
Default:
http://
This textbox contains the web address (or URL) of the HTML emulator’s start page.
The CommServer retrieves this page, parses it into TESS, and sends the TESS datastream by default to each terminal.
If the CommServer cannot retrieve the start page, it sends a simple page to the terminal containing a link to the start page. The user can then request the start page later by following the link. display size.
The scheme (the
http://
part) must be provided with the start page’s web address.
The TekHTML emulator expects it, and does not provide it if it is not specified.
The terminal requests the start page when the user presses the Home function key (see
page C-130 for information on selecting the Home function key).
Character Width on the Terminal Textbox
Character Width on the Terminal:
Values:
1 - 10
Default:
8
This textbox specifies the width in pixels of a single character on the terminal screen.
The emulator uses this width value when formatting web pages to fit the terminal screen.
C-84
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (HTML Emulation)
Passthru Checkbox
Passthru:
Values:
<enabled>, <disabled>
Default:
<disabled>
If this checkbox is selected, the CommServer allows the host to send data directly to the
RF terminal’s serial port. This is most commonly used for printing.
TSF/O Checkbox
TSF/O:
Values:
<enabled>, <disabled>
Default:
<disabled>
When this parameter is enabled, the host can use the Psion Teklogix Screen Formatter and Optimizer software.
Pages Textbox
Pages:
Values:
1 - 32
Default:
8
The number of host screens (or pages) stored at the terminal.
The CommServer reduces data transmitted to the terminals by using the terminal’s capability to store a page of data for each screen it displays. The CommServer maintains an image of each page stored at the terminal. After receiving an application screen, the
CommServer tries to match the screen with a stored page.
If a similar page is already in the terminal’s memory, the CommServer simply instructs the terminal to re-display its copy of the page; only the necessary changes are sent from the CommServer. If no match is found, the complete page is sent to the terminal over the radio link.
Note:
There is a corresponding parameter on the terminal itself, and the actual number of saved pages will be the smaller of the two values.
Psion Teklogix 9500 Communications Server User Manual
C-85
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (HTML Emulation)
Transmit Lines Textbox
Transmit Lines:
Values:
0 - 24
Default:
0
When this feature is enabled, all modified data at the terminal will be automatically transmitted when the operator enters data into a transmit-upon- entry field.
The value in this textbox specifies the line on the screen which is designated the
transmit line. The last entry field above or on the transmit line on the screen will be identified as the transmit-upon-entry field. If any entry fields exist on lines below the transmit line, no entry field will be designated as the transmit-upon-entry field.
A value of 0 (zero) disables this feature.
Field Overhead Textbox
Field Overhead:
Values:
1 - 80
Default:
5
This textbox specifies the maximum number of characters allowed between two fixed fields. The HTML emulator joins two adjacent fixed fields separated by this many or fewer characters, then sends them as one TESS field. This reduces the overhead on the radio link.
For example, if two fields were 4 characters apart and this parameter was 5, then these fields would be joined into one.
This feature affects fields with the “Normal” display attribute only.
C-86
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (Remote Sockets Emulation)
The Emulation Options Screen (Remote Sockets Emulation)
1
2
The CommServer displays this version of the Emulation Options screen after the user has selected the Remote Sockets emulation/protocol combinations for this host connection.
Note:
The screen shown here gives the emulation options for a host named
Unnamed Host.
This emulation is intended for a CommServer communicating with a Psion Teklogix device using the Remote Sockets proxy communications mechanism. There are no emulation options.
C.2.2.5 Protocol Options
This screen differs depending on the type of emulation and protocol selected in the
General Host Options screen.
There are nine variants of this screen for the following emulation and protocol combinations:
•
Telnet protocol (ANSI emulation). See page C-89.
•
Telnet protocol (2392 emulation). See page C-97.
•
Telnet protocol (3274 emulation). See page C-100.
•
Telnet protocol (5250 emulation). See page C-110.
•
Telnet protocol (9010 emulation). See page C-119.
Psion Teklogix 9500 Communications Server User Manual
C-87
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Emulation Options Screen (Remote Sockets Emulation)
•
Telnet protocol (RF modem emulation). See page C-120.
• SNA protocol (3274 emulation). See page C-106.
•
SNA protocol (5250 emulation). See page C-114.
•
HTML protocol/ emulation. See page C-121.
•
Remote Sockets protocol/emulation. See page C-122.
There are no configurable protocol options for the HTML or Remote Sockets protocol/emulation combinations.
C-88
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (ANSI Emulation / Telnet Protocol)
The Protocol Options Screen (ANSI Emulation / Telnet Protocol)
1
2
Psion Teklogix 9500 Communications Server User Manual
C-89
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (ANSI Emulation / Telnet Protocol)
The CommServer displays this version of the Protocol Options screen when the user selects the emulation/protocol combination of ANSI/Telnet for this host.
Note:
The screen shown here gives the emulation options for a host named
Daevid.
Terminal Type Listbox
Terminal Type:
Values:
VT-100, VT-220
Default:
VT-100
This listbox specifies the type of terminal to be emulated by the CommServer.
Host Port Textbox
Host Port:
Values:
1 - 32767
Default:
23
This textbox specifies the value for the host port for the selected ANSI host connection.
Maximum Sessions Per Terminal Textbox
Maximum Sessions per Terminal:
Values:
1 - 127
Default:
4
This textbox specifies the maximum number of telnet connections allowed to and from each terminal.
Close Host Sessions On Terminal Reset Checkbox
Close Host sessions on Terminal reset:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, all host sessions will be closed when the termiunal resets. If the checkbox is unselected, the sessions will remain open if the terminal resets.
C-90
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (ANSI Emulation / Telnet Protocol)
First Local Terminal Port Textbox
First Local Terminal Port:
Values:
1 - 32767
Default:
0
This textbox specifies the port number from which the CommServer attempts a telnet connection for the first terminal. Additional telnet sessions are assigned higher port numbers.
This parameter only takes effect if the Local IP Address to Bind parameter is specified.
Important:
Do not set the first local terminal port to 16100! Port 16100 is used as a listen port by hosts using Psion Teklogix’ 9010 protocol.
Local IP Address To Bind Textbox
Local IP Address to Bind:
Values:
<any valid IP address>
Default:
<none>
This textbox specifies the IP address of the CommServer interface that connects to this host. It is used along with the local port numbers to create a unique socket for each terminal session.
First Terminal Listen Port Textbox
First Terminal Listen Port:
Values:
<see text>
Default:
0
This textbox specifies the lowest port number at which the CommServer listens for telnet connections initiated by the host.
Note:
Entering a value of 0 disables this option.
TCP Session Request Textbox
TCP Session Request:
Values:
0 - 255
Default:
1
Psion Teklogix 9500 Communications Server User Manual
C-91
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (ANSI Emulation / Telnet Protocol)
This textbox contains the decimal ASCII character code of the character which, when entered at the terminal, requests a new ANSI terminal session.
Session Cycle Key Textbox
Session Cycle Key:
Values:
0 - 255
Default:
2
This textbox contains the decimal ASCII character code of the character which, when entered at the terminal, requests the next ANSI terminal session.
Last Active Session Key Textbox
Last Active Session Key:
Values:
0 - 255
Default:
5
This textbox contains the decimal ASCII character code of the character which, when entered at the terminal, requests the last ANSI terminal session.
Auto-Telnet/Auto-Login Enable Listbox
Auto-Telnet/Login Enable:
Values:
Disable; Auto-Telnet; Auto-Telnet/Login
Default:
Disable
This listbox enables the user to disable or enable automatic connection of telnet sessions from terminals to this host.
The choices provided are to disable auto-telnet, to enable auto-telnet, and to enable auto-telnet and auto-login.
When auto-telnet is disabled, telnet sessions from the terminals to the host must be initiated manually from the terminals.
When auto-telnet is enabled, the CommServer initiates one telnet session from each terminal whose terminal number is mapped to this host. Additional telnet sessions may be initiated from each terminal to the host, but they must be initiated manually.
Note:
Auto-telnet sessions are only initiated for terminals which are ‘online’ (that is, turned on and operating properly on the Psion Teklogix RF network).
C-92
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (ANSI Emulation / Telnet Protocol)
When auto-telnet and auto-login are enabled, the CommServer initiates one telnet session from each terminal whose terminal number is mapped to this host. It then logs each session in to the host using the username and password provided in this screen.
Note:
The usename and password is identical for all auto-telnet sessions automatically logged in to this host.
Auto-Telnet Host Textbox
Auto-Telnet Host:
Values:
valid host name or IP address
Default:
<none>
This textbox contains the host name or IP address for the host to which the CommServer connects auto-telnet sessions.
Note:
A host name placed in this textbox must be resolvable by the CommServer:
the CommServer must be able to obtain an IP address for it. For example, the host name may correspond to an entry in the CommServer’s host table, or the
CommServer may be able to query a domain-name server.
Any host name which can be used at the terminal’s TCP> prompt may be used here.
Auto-Telnet Terminal Prompt Textbox
Auto-Telnet Terminal Prompt:
Values:
any ASCII string. Max 60 characters
Default:
Press ENTER to login.
This textbox contains the text presented to the user to request a login.
Non-printable characters, such as are used in escape sequences, are allowed. These characters can be entered using either octal or hexadecimal digits.
An octal escape sequence takes one of the forms:
\0d
or
\0dd
or
\0ddd
where each d can be any digit
0
-
7
.
A hexadecimal escape sequence takes one of the forms:
\xh
or
\xhh
where each
h
can be
0
-
9
, or any of
a
-
f
or
A
-
F
.
Psion Teklogix 9500 Communications Server User Manual
C-93
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (ANSI Emulation / Telnet Protocol)
Each of these numeric escape sequences encodes one character. For example, the sequence "
\033abc
" becomes the character array {
033
,'
a
','
b
','
c
',
0
}
Notes:
1. If the octal
ddd
is greater than decimal 256, the code value of the represented character will be the remainder of decimal
ddd
/256.
2. "
\0
" is considered as a character with a code value of 0.
Auto-Login User ID Textbox
Auto-Login User ID:
Values:
any ASCII string acceptable to the host. Max 15 characters
Default:
<none>
This textbox contains the user ID presented by the CommServer to the host for the auto-login sessions.
Auto-Login Password Textbox
Auto-Login Password:
Values:
any ASCII string acceptable to the host.
Max 15 characters
Default:
<none>
This textbox contains the password presented by the CommServer to the host for the auto-login sessions.
Auto-Login User ID Prompt Textbox
Auto-Login User ID Prompt:
Values:
any ASCII string. Maximum 15 characters
Default:
gin:
The CommServer compares the text in this textbox to the text presented to it by the host.
When they match, the CommServer assumes that the host has just sent its request for a user name, and it sends the username specified in the Auto-Login User ID parameter to the host.
C-94
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (ANSI Emulation / Telnet Protocol)
Note:
The match string should be as short as possible, yet long enough to uniquely identify the user-ID prompt.
It is strongly advised not to include multi-part words separated by space characters, since some hosts send out characters other than space characters to present a space on the screen.
Auto-Login Password Prompt Textbox
Auto-Login Password Prompt:
Values:
any ASCII string. Maximum 15 characters
Default:
word:
The CommServer compares the text in this textbox to the text presented to it by the host.
When they match, the CommServer assumes that the host has just sent its request for a password, and it sends the password specified in the Auto-Login Password parameter to the host.
Note:
The match string should be as short as possible, yet long enough to uniquely identify the password prompt.
It is strongly advised not to include multi-part words separated by space characters, since some hosts send out characters other than space characters to present a space on the screen.
Auto-Login Failed Prompt Textbox
Auto-Login Failed Prompt:
Values:
any ASCII string. Maximum 15 characters
Default:
incorrect
The CommServer compares the text in this textbox to the text presented to it by the host.
When they match, the CommServer assumes that the host has just sent a string informing the terminal of a failed login attempt. The CommServer then presents the
Auto-Telnet Terminal Prompt on the terminal’s screen to request the user to login manually.
Note:
The match string should be as short as possible, yet long enough to uniquely identify the failed-login prompt.
Psion Teklogix 9500 Communications Server User Manual
C-95
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (ANSI Emulation / Telnet Protocol)
It is strongly advised not to include multi-part words separated by space characters, since some hosts send out characters other than space characters to present a space on the screen.
Auto-Telnet Without User Action Checkbox
Auto-telnet without user action:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer will attempt to connect to the host as soon as a terminal initializes, and it will attempt to reconnect if the telnet session is closed.
Auto-telnet Without User Action Timing Delay Textbox
Auto-telnet without user action timing delay:
Values:
0 - 15
Default:
1
This parameter specifies the number of milliseconds between auto-telnet connection requests sent to the host.
All requests to connect without user action are queued, and are processed with this delay between requests. This to prevent flooding host with connection and logins when the
CommServer starts or is reset.
Maximum Number Of Auto-Telnet Retries Textbox
Maximum number of auto-telnet retries:
Values:
0 - 15
Default:
1
This parameter specifies the number of times the CommServer will attenpt to connect to a host if the host doesn't respond. If this parameter is zero, the CommServer attempts to connect forever.
Allow TCP Sessions Checkbox
Allow TCP Sessions:
Values:
<selected>, <unselected>
C-96
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (2392 Emulation / Telnet Protocol)
Default:
<selected>
If this checkbox is unselected, and auto-telnet is enabled, all sessions requested by the terminal to this host emulation will be Auto-Login sessions.
If this checkbox is selected, sessions requested by the terminal can be either auto-iogin or TCP sessions. At the prompt of a TCP session, the operator can specify the desired host to connect to, and provide username and password.
On the terminal, <CTRL>+A requests a new session, <CTRL>+B changes to the next available session, and <CTRL>+E changes to the last available session.
The Protocol Options Screen (2392 Emulation / Telnet Protocol)
1
2
The CommServer displays this version of the Protocol Options screen when the user selects the emulation/protocol combination of 2392/Telnet for this host.
Note:
The screen shown here gives the protocol options for a host named Elaine.
Psion Teklogix 9500 Communications Server User Manual
C-97
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (2392 Emulation / Telnet Protocol)
Host Port Textbox
Host Port:
Values:
1 - 32767
Default:
23
This textbox allows the user to enter a host port value for the selected 2392 telnet host connection.
Maximum Sessions per Terminal Textbox
Maximum Sessions per Terminal:
Values:
0 - 127
Default:
4
This textbox contains the maximum number of telnet sessions which are allowed to originate from each terminal.
First Local Terminal Port Textbox
First Local Terminal Port:
Values:
1024 - 32767
Default:
0
This textbox contains the port number from which the first terminal will connect on outbound telnet sessions.
Local IP Address to Bind Textbox
Local IP Address to Bind:
Values:
<any valid IP address>
Default:
0.0.0.0
This textbox contains the IP address of the network adaptor in the CommServer from which the first terminal will connect on outbound telnet sessions.
First Terminal Listen Port Textbox
First Terminal Listen Port:
Values:
0 - 32767
C-98
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (2392 Emulation / Telnet Protocol)
Default:
10000
This textbox specifies the first port number at which the CommServer will listen for telnet connection requests to the terminals.
Note:
Entering a value of 0 disables this option.
Auto-telnet/login Enable Listbox
Auto-telnet/login enable:
Values:
DISABLE, AUTO-TELNET
Default:
DISABLE
This listbox allows the user to choose whether auto-telnet sessions are allowed to connect to this host.
Auto-telnet Host Textbox
Auto-telnet Host:
Values:
<any host ID>
Default:
<none>
This parameter specifies a host ID to which auto-telnet requests will be directed.
Auto-Telnet Without User Action Checkbox
Auto-Telnet Without User Action:
Values:
<selected>, <unselected>
Default:
<selected>
If this checkbox is selected, the CommServer will attempt to connect to a configured
Auto-Telnet host by auto-telnet whenever that host is available.
Psion Teklogix 9500 Communications Server User Manual
C-99
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (3274 Emulation / Telnet Protocol)
The Protocol Options Screen (3274 Emulation / Telnet Protocol)
1
2
The CommServer displays this version of the Protocol Options screen when the user selects the emulation/protocol combination of 3274/Telnet for this host.
Note:
The screen shown here gives the protocol options for a host named 3274.
Terminal Type Listbox
Terminal Type:
Values:
IBM 3278-2
Default:
IBM 3278-2
C-100
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (3274 Emulation / Telnet Protocol)
This textbox allows the user to choose the type of terminal to be emulated by the
CommServer for this host. At present there is only one choice of terminal for
3274/Telnet: the IBM 3278-2.
Host Port Textbox
Host Port:
Values:
1 - 32767
Default:
23
This textbox allows the user to enter a host port value for the selected 3274 telnet host connection.
Maximum Sessions Per Terminal Textbox
Maximum Sessions per Terminal:
Values:
0 - 127
Default:
4
This textbox contains the maximum number of telnet sessions which are allowed to originate from each terminal.
First Local Terminal Port Textbox
First Local Terminal Port:
Values:
1024 - 32767
Default:
0
This textbox contains the port number from which the first terminal will connect on outbound telnet sessions.
Local IP Address To Bind Textbox
Local IP Address to Bind:
Values:
<any valid IP address>
Default:
0.0.0.0
This textbox contains the IP address of the network adaptor in the CommServer from which the first terminal will connect on outbound telnet sessions.
Psion Teklogix 9500 Communications Server User Manual
C-101
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (3274 Emulation / Telnet Protocol)
First Terminal Listen Port Textbox
First Terminal Listen Port:
Values:
0 - 32767
Default:
10000
This textbox specifies the first port number at which the CommServer will listen for telnet connection requests to the terminals.
Note:
Entering a value of 0 disables this option.
Actively Negotiate With Host Checkbox
Actively Negotiate With Host:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer negotiates with the host during setup of the telnet connection.
Configure LU Names Checkbox
Configure LU Names: Configure
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, individual terminals can be assigned Logical Unit names when communicating with this 3274 host. Terminal names can be configured in the
Terminal Naming screen; this is accessible through the Configure button. See “The
3274 Telnet Terminal Naming Screen” on page C-104.
LU Name Prefix Textbox
LU Name Prefix:
Values:
<see text>
Default:
<none>
This textbox specifies the LU prefix to be prepended to terminal names when the
Configure LU Names parameter is enabled. The prefix can be up to three alphanumeric characters.
C-102
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (3274 Emulation / Telnet Protocol)
Send IAC Interrupt Process As A System Request Checkbox
Send IAC Interrupt Process as a System Request:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer sends the IAC Interrupt Process request to the host as a 3274 System Request.
Send IAC Break As An Attention Key Checkbox
Send IAC Break as an Attention Key:
Values:
<selected>, <unselected>
Default:
<unselected>
If this checkbox is selected, the CommServer sends the IAC Break request to the host as a 3274 Attention Key.
Auto-telnet/login Enable Listbox
Auto-telnet/login enable:
Values:
DISABLE, AUTO-TELNET
Default:
DISABLE
This listbox allows the user to choose whether auto-telnet sessions are allowed to connect to this host.
Auto-telnet Host Textbox
Auto-telnet Host:
Values:
<any host ID>
Default:
<none>
This parameter specifies a host ID to which auto-telnet requests will be directed.
Auto-Telnet Without User Action Checkbox
Auto-Telnet Without User Action:
Values:
<selected>, <unselected>
Default:
<selected>
Psion Teklogix 9500 Communications Server User Manual
C-103
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The 3274 Telnet Terminal Naming Screen
If this checkbox is selected, the CommServer will attempt to connect to a configured
Auto-Telnet host by auto-telnet whenever that host is available.
The 3274 Telnet Terminal Naming Screen
1
2
The CommServer displays this screen after the user has pressed the Configure button next to the Configure LU Names parameter.
Terminal Number Textbox
Terminal Number:
Values:
1 - <number of configured terminals>
Default:
<none>
This textbox specifies the number of the terminal which will receive the name in the
Terminal Name textbox.
Terminal Name Textbox
Terminal Name:
Values:
<see text>
Default:
<none>
C-104
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The 3274 Telnet Terminal Naming Screen
This textbox specifies an LU name for the terminal. This name can contain no more than
1-5 alphanumeric characters.
If no terminal name is specified here for a terminal, the 9500 will append the terminal number (as five digits, with leading zeros if necessary) to the LU Prefix to create the full
LU terminal name.
Show/Set Button
Show/Set
Press the Show/Set button to display the LU name associated with a terminal number.
If you have just entered a terminal number and LU name, press this button to add the terminal number and LU name to the list of configured terminals.
Delete Button
Delete
The Delete button allows the user to delete the currently-displayed terminal number and
LU name from the list. When it is pressed, the 9500 displays a confirmation screen.
Press OK in this screen to delete the terminal name and number from the list.
OK Button
OK
The OK button saves changes to the database. When it is pressed, the 9500 displays a confirmation screen. Press OK in this screen to save the changes and exit to the main
3274/SNA Protocol Options screen.
Validate Button
Validate
The Validate button allows the user to save the changes to the 9500’s database without exiting from the Terminal Naming screen. The changes can also be saved through the
Main Screen’s validation and saving option.
Psion Teklogix 9500 Communications Server User Manual
C-105
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (3274 Emulation / SNA Protocol)
Show Terminals Button
Show Terminals
The Show Terminals button displays the list of currently-configured terminal names.
When it is pressed, the 9500 displays the Terminal Names screen:
This screen displays the configured terminal numbers and names. Press OK to return to the Terminal Naming screen.
The Protocol Options Screen (3274 Emulation / SNA Protocol)
1
2
The CommServer displays this version of the Protocol Options screen after the user has selected the 3274/SNA emulation/protocol combination for this host connection.
C-106
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (3274 Emulation / SNA Protocol)
Note:
The screen shown here gives the protocol options for a host named Eleanor.
Attention Key Listbox
Attention Key:
Values:
ENTER, ATTN
Default:
ENTER
This listbox specifies the character sent back to the host when the user presses the
<ATTN> function key on a Psion Teklogix terminal.
Note:
The actual key used at the terminal to obtain the <ATTN> function key is configurable through the Function Key Mapping screen for this host connection.
Use SSCP Sessions Checkbox
Use SSCP Sessions:
Values:
<selected>, <unselected>
Default:
<selected>
This checkbox indicates the type of sessions that can be used.
When this parameter is selected, the CommServer will attempt to establish an SSCP-
LU session for a terminal before establishing an LU-LU session. Depending on the type of host, an SSCP-LU session may or may not be created.
When this parameter is not selected, only LU-LU sessions will be used.
When the OK button is pressed, the CommServer displays a confirnmation screen:
This screen includes the following button:
Psion Teklogix 9500 Communications Server User Manual
C-107
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (3274 Emulation / SNA Protocol)
Update LU Session Information Button
Update LU Session Information
The Update LU Session Information button allows the user to update the information being passed to the CommServer’s SNA software.
When the Update LU Session Information button is pressed, the CommServer displays an Update Confirmation screen:
This screen lists the information that will be changed in the CommServer’s SNA configuration:
• The path and filename of the configuration file that will be updated. This is the configuration file that has been selected as the default in the SNA software.
(See page 165.)
• The terminal number of the first terminal for this host emulation.
• The terminal number of the last terminal for this host emulation.
• The LU prefix.
• The PU name for this host emulation’s LUs.
C-108
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (3274 Emulation / SNA Protocol)
The PU name is optional and may be specified in this screen. It is only needed if the administrator is connecting to a host that has multiple PUs configured, and wishes to specify which PU is to be used by the CommServer.
When the Update button is pressed, the CommServer changes the configuration file and displays a confirmation screen similar to this screen.
Press OK in this screen to return to the Main Menu.
Psion Teklogix 9500 Communications Server User Manual
C-109
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (5250 Emulation / Telnet Protocol)
The Protocol Options Screen (5250 Emulation / Telnet Protocol)
1
2
The CommServer displays this version of the Protocol Options screen when the user selects the emulation/protocol combination of 5250/Telnet for this host.
Note:
The screen shown here gives the protocol options for a host named Deanna.
Terminal Type Textbox
Terminal Type:
Values:
IBM 5251-11, IBM 5555-B01
Default:
IBM 5251-11
This textbox allows the user to select a terminal type which the CommServer will emulate.
C-110
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (5250 Emulation / Telnet Protocol)
Host Port Textbox
Host Port:
Values:
1 - 32767
Default:
23
This textbox allows the user to enter a host port value for the selected 5250 telnet host connection.
Maximum Sessions Per Terminal Textbox
Maximum Sessions per Terminal:
Values:
0 - 127
Default:
4
This textbox contains the maximum number of telnet sessions which are allowed to originate from each terminal.
First Local Terminal Port Textbox
First Local Terminal Port:
Values:
1024 - 32767
Default:
0
This textbox contains the port number from which the first terminal will connect on outbound telnet sessions.
First Terminal Listen Port Textbox
First Terminal Listen Port:
Values:
0 - 32767
Default:
10000
This textbox specifies the first port number at which the CommServer will listen for telnet connection requests to the terminals.
Note:
Entering a value of 0 disables this option.
Psion Teklogix 9500 Communications Server User Manual
C-111
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (5250 Emulation / Telnet Protocol)
Local IP Address To Bind Textbox
Local IP Address to Bind:
Values:
<any valid IP address>
Default:
0.0.0.0
This textbox contains the IP address of the network adaptor from which the first terminal will connect on outbound telnet sessions.
Actively Negotiate With Host Checkbox
Actively Negotiate With Host:
Values:
<selected>, <unselected>
Default:
<unselected>
If this textbox is selected, the CommServer negotiates with the host during setup of the telnet connection.
Auto-telnet/login Enable Listbox
Auto-telnet/login enable:
Values:
DISABLE, AUTO-TELNET
Default:
DISABLE
This listbox allows the user to choose whether auto-telnet sessions are allowed to connect to this host.
Auto-telnet Host Textbox
Auto-telnet Host:
Values:
<any host ID>
Default:
<none>
This parameter specifies a host ID to which auto-telnet requests will be directed.
Auto-Telnet Without User Action Checkbox
Auto-Telnet Without User Action:
Values:
<selected>, <unselected>
Default:
<selected>
C-112
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (5250 Emulation / Telnet Protocol)
If this checkbox is selected, the CommServer will attempt to connect to a configured
Auto-Telnet host by auto-telnet whenever that host is available.
Negotiate Virtual Device Name With Host Checkbox
Negotiate Virtual Device Name with Host:
Values:
<selected>, <unselected>
Default:
<unselected>
If this textbox is selected, the CommServer negotiates with the host to obtain a virtual device name for the telnet connection.
Virtual Device Name Prefix Textbox
Virtual Device Name Prefix:
Values:
<any host ID>
Default:
<none>
This parameter specifies a prefix for the automatically-generated virtual device name.
The device name on the host starts with the prefix, specifies the terminal (as its terminal number), and specifies a session number (as a letter). If the virtual device name prefix is
TLX, for example, the first session on terminal number 2 receives a virtual device name of TLX0002A.
The prefix must use the SNA Type A character set, which includes uppercase letters A–
Z, numbers 0–9, and the special characters $, # and @. Lower case letters are accepted and translated to uppercase characters. An SNA Type A character string must not begin with a number.
Psion Teklogix 9500 Communications Server User Manual
C-113
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (5250 Emulation / SNA Protocol)
The Protocol Options Screen (5250 Emulation / SNA Protocol)
1
2
The CommServer displays this version of the Protocol Options screen after the user has selected the 5250/SNA emulation/protocol combination for this host connection.
Note:
The screen shown here gives the protocol options for a host named
“5250 SNA”.
Host Name Textbox
Host Name:
Values:
<see text>
Default:
TLXLCPN
C-114
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (5250 Emulation / SNA Protocol)
This textbox contains the local host name for this host connection.
The name must use the SNA Type A character set, which includes uppercase letters A–
Z, numbers 0–9, and the special characters $, # and @. Lower case letters are accepted and translated to uppercase characters. An SNA Type A character string must not begin with a number 0–9.
User Name Textbox
User Name:
Values:
<see text>
Default:
TEKUSER
This textbox contains the user name for this host connection. This is for security verification of the host connection only, when the connection is made to the host. The user must still log in normally.
The user name must use the SNA Type A character set, which includes uppercase letters
A–Z, numbers 0–9, and the special characters $, # and @. Lower case letters are accepted and translated to uppercase characters. An SNA Type A character string must not begin with a number.
Password Textbox
Password:
Values:
<see text>
Default:
TEKPASS
This textbox contains the password for this host connection. This is for security verification of the host connection only, when the connection is made to the host. The user must still log in normally.
The password must use the SNA Type A character set, which includes uppercase letters
A–Z, numbers 0–9, and the special characters $, # and @. Lower case letters are accepted and translated to uppercase characters. An SNA Type A character string must not begin with a number.
Enable Connect Screen Checkbox
Enable Connect Screen:
Values:
<selected>, <unselected>
Default:
<unselected>
Psion Teklogix 9500 Communications Server User Manual
C-115
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (5250 Emulation / SNA Protocol)
If this checkbox is selected, the CommServer sends a special screen to the terminal when it is unable to connect to the host. Pressing <ENTER> on the terminal causes the
CommServer to reattempt connection to the host.
Reconnection Timeout Textbox
Reconnection Timeout:
Values:
<see text>
Default:
30
This textbox specifies the maximum amount of time that the CommServer will wait for a reply when attempting a connection to the host. If there is no reply, it will attempt another connection, to the maximum number of times specified in the Maximum
Reconnection Attempts parameter below.
Maximum Reconnection Attempts Textbox
Maximum Reconnection Attempts:
Values:
<see text>
Default:
3
This textbox specifies the maximum number of times that the CommServer attempts to connect to the host if the first attempt fails.
The Mode Parameters
Each SNA mode has four associated parameters: Name, LU Prefix, First terminal number, and Last terminal number.
Name Textbox
Name:
Values:
<see text>
Default:
QPCSUPP
This listbox contains the name of the mode on the host to use.
The name must use the SNA Type A character set, which includes uppercase letters A–Z, numbers 0–9, and the special characters $, # and @. Lower case letters are accepted and translated to uppercase characters. An SNA Type A character string must not begin with a number.
C-116
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (5250 Emulation / SNA Protocol)
LU Prefix Textbox
LU Prefix:
Values:
<see text>
Default:
TLX
This textbox contains the exchange identifier for this host connection.
This is the prefix attached to the terminal number to form the LU name. The prefix may be 1 to 5 characters long, and the terminal number may be 1 to 4 characters long. The maximum length of the LU name formed from these is eight characters.
First Terminal Textbox
First Terminal:
Values:
<see text>
Default:
1
This textbox contains the number of the first terminal which uses this mode and this host connection.
Last Terminal Textbox
Last Terminal:
Values:
<see text>
Default:
32
This textbox contains the number of the last terminal which uses this mode and this host connection.
When the OK button is pressed, the CommServer displays a confirnmation screen:
This screen includes the following button:
Psion Teklogix 9500 Communications Server User Manual
C-117
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (5250 Emulation / SNA Protocol)
Update LU Session Information Button
Update LU Session Information
The Update LU Session Information button allows the user to update the information being passed to the CommServer’s SNA software. When it is pressed, the CommServer displays an Update Confirmation screen:
This screen lists the following information:
• The path and filename of the configuration file that will be updated.
This is the configuration file that has been selected as the default in the SNA software. (See page 208).
• The LU prefix for terminals using the QPCSUPP mode, and which terminals are using it.
When the Update button is pressed, the CommServer changes the configuration file and displays a confirmation screen similar to this screen.
Press OK in this screen to return to the Main Menu.
C-118
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (9010 Emulation / Telnet Protocol)
The Protocol Options Screen (9010 Emulation / Telnet Protocol)
1
2
The CommServer displays this version of the Protocol Options screen after the user has selected the 9010 / Telnet emulation/protocol combination for this host connection.
Note:
The screen shown here gives the emulation options for a host named Bob.
Monitor Polls Checkbox
Monitor Polls:
Values:
<selected>, <unselected>
Default:
<selected>
Hosts usually send messages or null polls to the CommServer within a period of approximately 40 seconds. If this checkbox is selected, the CommServer monitors messages and polls from this connection; if it does not receive a message or poll within
40 seconds, it closes the connection.
Note:
For older Unix handlers (hosts), this parameter should be deselected. In all other cases, this parameter should be selected.
Psion Teklogix 9500 Communications Server User Manual
C-119
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (RF Modem Emulation / Telnet Protocol)
The Protocol Options Screen (RF Modem Emulation / Telnet Protocol)
1
2
The CommServer displays this version of the Protocol Options screen after the user has selected the RF Modem / Telnet emulation/protocol combination for this host connection.
Note:
The screen shown here gives the emulation options for a host named Greg.
The RF Modem protocol is used with the Psion Teklogix Model 6040 RF Modem. This device acts as a terminal on the Psion Teklogix network, but data sent to it is forwarded through a serial port to another serially-connected device. Serial devices may thus communicate over the Psion Teklogix radio network.
See the Psion Teklogix 6040 RF Modem User Manual for details.
C-120
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (HTML Emulation)
First Terminal Listen Port Listbox
First Terminal Listen Port:
Values:
10000 - 65535
Default:
10000
This textbox contains the number of the first port upon which the CommServer listens for telnet connections from the host.
Note:
Entering a value of 0 disables this option.
The Protocol Options Screen (HTML Emulation)
1
2
The CommServer displays a version of the Protocol Options screen with no configurable options after the user has selected the HTML emulation/protocol combination for this host connection.
Note:
The screen shown here gives the emulation options for a host named Aline.
Psion Teklogix 9500 Communications Server User Manual
C-121
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The Protocol Options Screen (Remote Sockets Emulation)
The Protocol Options Screen (Remote Sockets Emulation)
1
2
The CommServer displays a version of the Protocol Options screen with no configurable options after the user has selected the Remote Sockets emulation/protocol combination for this host connection.
Note:
The screen shown here gives the emulation options for a host named
Unnamed Host.
C-122
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
C.2.2.6 Function Key Mapping
This screen differs depending on the type of emulation selected in the General Host
Options screen. There are five variants of this screen, depending on the emulation/protocol combination chosen for the host:
• ANSI function-key and arrow-key mapping (for the ANSI/Telnet emula-
tion/protocol combination). See page C-124.
• 3274 function-key mapping (for the 3274/Telnet and 3274/SNA emulation/pro-
tocol combinations). See page C-127.
• 5250 function-key mapping (for the 5250/Telnet and 5250/SNA emulation/pro-
tocol combinations). See page C-129.
•
HTML function-key mapping (for HTML emulation). See page C-130.
• No function-key mapping (for the 2392/Telnet, 9010/TCP/IP, RF Modem/Tel-
net and Remote Sockets emulation/protocol combinations). See page C-132.
Psion Teklogix 9500 Communications Server User Manual
C-123
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The ANSI Function And Arrow Key Mapping Screen
The ANSI Function And Arrow Key Mapping Screen
1
2
The CommServer displays this version of the Function Key Mapping screen after the user selects the ANSI/Telnet emulation/protocol combination for this host. This screen also includes arrow-key mappings.
C-124
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The ANSI Function And Arrow Key Mapping Screen
Note:
The screen shown here gives the function-key options for a host named Gary.
Function Key n Listbox
Fn:
Values:
<see text>
Default:
<see text>
The function key textboxes allow the user to select a code that will be sent to the host when the user presses a function key on the terminal. Each function key may be chosen from the same range of possible codes; however, each function key has a different default code.
A null entry terminates the map-to sequence; it is not necessary to transmit nulls.
Arrow Key Listbox
<arrow key name>:
Values:
<see text>
Default:
<see text>
The arrow key textboxes allow the user to select a code that will be sent to the host when the user presses one of the four arrow keys on the ANSI terminal. There are four arrow key listboxes, one for each of the Up, Down, Left and Right arrow keys. Each arrow key may be chosen from the same range of possible codes; however, each arrow key has a different default code.
Arrow key remapping does exist in the terminals, but is applicable only to telnet direct connections.
Function-key remapping and arrow-key remapping can be enabled, and operate, independently of each other.
Arrow key sequences sent from the terminal can be switched between ‘Application’ mode and ‘Cursor Key’ mode by the DECCKM command sent by the host. The sequences ares
CSI?1h
and
CSI?1l
There is also a local parameter on the terminal that can choose this mode.
Psion Teklogix 9500 Communications Server User Manual
C-125
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The ANSI Function And Arrow Key Mapping Screen
The default arrow key sequences (in Psion Teklogix ANSI debug format) are:
In Cursor-Key Mode
Up arrow
Down arrow
7-Bit 8-Bit
(1b)[A (9b)A
(1b)[B (9b)B
Right arrow
Left arrow
In Application Mode
Left arrow
Right arrow
Up arrow
Down arrow
(1b)[C (9b)C
(1b)[D (9b)D
(1b)OA (8f)A
(1b)OB (8f)B
(1b)OC (8f)C
(1b)OD (8f)D
These sequences are remapped by the Communications Server to 4 configurable sequences, each a minimum of 5 hex characters long. A null entry terminates the mapto sequence; it is not necessary to transmit nulls.
The default values for arrow key mappings are the 7-bit Cursor key Mode values shown above. The CommServer recognizes both the 7-bit and the 8-bit forms of the key sequences.
The same escape timeout applies to arrow key remapping as to function key remapping.
The ‘cursor key mode’ parameter setting in the terminal is not considered by the
CommServer. If the host changes the key sequence using DECCKM, the CommServer continues to remap the new key sequences. In other words, with arrow key mapping enabled, DECCKM will have no net effect.
C-126
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The 3274 Function Key Mapping Screen
The 3274 Function Key Mapping Screen
1
2
The CommServer displays this version of the Function Key Mapping screen after the user selects the 3274/ANSI or 3274/SNA emulation/protocol combinations for this host.
Note:
The screen shown here gives the function-key options for a host named Fred.
Psion Teklogix 9500 Communications Server User Manual
C-127
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The 3274 Function Key Mapping Screen
Function Key n Listbox
Fn:
Values:
ENTER, NONE, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10,
F11, F12, F13, F14, F15, F16, F17, F18, F19, F20,
F21, F22, F23, F24, PA1, PA2, PA3, PA4, ATTN, CLEAR,
RESET, SELECTOR, SESS, SYSREQ
Default:
<see text>
The function key textboxes allow the user to select a code that will be sent to the host when the user presses a function key on the terminal. Each function key may be chosen from the same range of possible codes; however, each function key has a different default code.
C-128
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The 5250 Function Key Mapping Screen
The 5250 Function Key Mapping Screen
1
2
The CommServer displays this version of the Function Key Mapping screen after the user selects one of the 5250/Telnet or 5250/SNA emulation/protocol combinations for this host.
Note:
The screen shown here gives the function-key options for a host named Bob.
Psion Teklogix 9500 Communications Server User Manual
C-129
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The HTML Function Key Mapping Screen
Function Key n Listbox
Fn:
Values:
ENTER, NONE, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10,
F11, F12, F13, F14, F15, F16, F17, F18, F19, F20,
F21, F22, F23, F24, PA1, PA2, PA3, PA4, ATTN, CLEAR,
RESET, SELECTOR, SESS, SYSREQ
Default:
<see text>
The function key textboxes allow the user to select a code that will be sent to the host when the user presses a function key on the terminal. Each function key may be chosen from the same range of possible codes; however, each function key has a different default code.
The HTML Function Key Mapping Screen
1
2
The CommServer displays this version of the Function Key Mapping screen after the user selects HTML emulation for this host.
Note:
The screen shown here gives the function-key options for a host named Aline.
The Forward, Back, and Home function-keys correspond to similar Forward, Back and
Home buttons in a standard web-browser. The Reset key resets the connection between the terminal and the CommServer.
C-130
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Controller Configuration: The Host Screens
The HTML Function Key Mapping Screen
Home Listbox
Values:
F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12,
F13, F14, F15, F16, F17, F18, F19, F20, F21, F22,
F23, F24, F25, F26, F27, F28, F29, F30
Default:
F1
This listbox allows the user to select the function key which requests the default page. In
TekHTML browser emulation, this requests the start page defined in the Emulation
Options screen (see page C-83).
Back Listbox
Values:
F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12,
F13, F14, F15, F16, F17, F18, F19, F20, F21, F22,
F23, F24, F25, F26, F27, F28, F29, F30
Default:
F2
This listbox allows the user to select the function key which requests the previouslyviewed page from the CommServer.
Forward Listbox
Values:
F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12,
F13, F14, F15, F16, F17, F18, F19, F20, F21, F22,
F23, F24, F25, F26, F27, F28, F29, F30
Default:
F3
This listbox allows the user to select the function key which requests the next page from the CommServer. This key works only if the user has previously pressed the Back function-key.
Reset Listbox
Values:
F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12,
F13, F14, F15, F16, F17, F18, F19, F20, F21, F22,
F23, F24, F25, F26, F27, F28, F29, F30
Default:
F30
This listbox allows the user to select the function key which resets the connection between the terminal and the CommServer.
Psion Teklogix 9500 Communications Server User Manual
C-131
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The Base Station Screens
The Function Key Mapping Screen (2392, 9010, RF Modem, Remote Sockets)
The Function Key Mapping Screen (2392, 9010, RF Modem, Remote Sockets)
1
2
The CommServer displays this or a similar version of the Function Key Mapping screen after the user selects one of the 2392/Telnet, 9010/TCP/IP, RF Modem, or Remote
Sockets emulation/protocol combinations for this host.
Note:
The screen shown here gives the options for a host named Greg.
These emulations do not have function key parameters.
C.2.3 CommServer Configuration: The Base Station Screens
Base Stations listbox on Configuration Main Menu:
[1] Example Base
Configure
[#] Create New
[1] Example Base
Configure New Base
Base Station Menu
The base station screens of the CommServer are accessible from the Base Stations listbox and selection button.
Base stations coordinate their own radio-link timing, unlike Remote Radio Modules
(RRMs), which are coordinated by the CommServer. See “CommServer Configuration:
The RRM Groups Screens” on page E-140 for more information on configuring RRMs.
C-132
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The Base Station Screens
C.2.3.1 Configure New Base Station
1
2
In this screen, the user can set options for a new base station.
Name Textbox
Name:
Values:
<any text string>
Default:
Unnamed Base Station
This textbox allows the user to enter a name for the new base station.
Protocol Listbox
Type:
Values:
TCP/IP
Default:
TCP/IP
This listbox allows the user to select the protocol to be used for the connection to this base station. Currently, the TCP/IP protocols is available.
Psion Teklogix 9500 Communications Server User Manual
C-133
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The Base Station Screens
First Terminal Textbox
First Terminal:
Values:
1 - 3840 <see text>
Default:
1
This textbox allows the user to specify the Psion Teklogix terminal number of the first terminal which will communicate with this base station.
Note:
This parameter has a maximum of 50 on the Model S900L software-only version of the CommServer, since this version can handle a maximum of 50 terminals.
Message Size Textbox
Message Size:
Values:
32 - 380
Default:
100
This textbox allows the user to specify the size (in number of characters) of the largest single message that can be passed to a terminal in a single packet. Longer messages are broken into several packets.
Notes:
• This parameter only applies when the CommServer is using the
cellular polling protocol (the Use Cellular Protocol checkbox in the
CommServer’s Radio Link Features screen has been checked).
• In systems using the Wireless LAN protocol, the maximum value for this parameter is 380. In systems using the polling protocol, the maximum value is 116.
Auto-Startup Checkbox
Auto-Startup:
Values:
<selected>, <unselected>
Default:
<selected>
If this checkbox is selected, the CommServer commands the base station to start polling after the CommServer is turned on.
C-134
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The Base Station Screens
Note:
If the CommServer is being configured as a slave controller, the “Auto Startup” parameter should be disabled.
C.2.3.2 The Base Station Menu
1
2
When the user chooses an existing base station from the Base Stations listbox and then presses the Configure button, the CommServer displays the Base Station Menu.
Note:
The screen shown here is for a base station named Velma.
The Base Station Menu has two Configure buttons, which are located next to the following text:
• General Options
When the user presses this Configure button, the CommServer displays the
Configure Base Station screen.
• Connectivity Options
When the user presses this Configure button, the CommServer displays the
Connectivity Options screen for this base station.
The Base Station Menu also has a Main Menu button. When the user presses the Main
Menu button, the CommServer displays the Configuration Main Menu.
Psion Teklogix 9500 Communications Server User Manual
C-135
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The Base Station Screens
C.2.3.3 General Options
1
2
In this screen, the user can select general options for this base station. The base station may also be deleted.
Note:
The screen shown here gives the configuration options for a base station named Velma.
Name Textbox
Name:
Values:
<any text string>
Default:
Unnamed Base Station
This textbox allows the user to enter a name for the base station.
C-136
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The Base Station Screens
Protocol Listbox
Type:
Values:
TCP/IP
Default:
TCP/IP
This listbox allows the user to select the protocol to be used for the connection to this base station. Currently only the TCP/IP protocol is available.
First Terminal Textbox
First Terminal:
Values:
1 - 3840 <see text>
Default:
1
This textbox allows the user to specify the Psion Teklogix terminal number of the first terminal which will communicate with this base station.
Note:
This parameter has a maximum of 50 on the Model S900L software-only version of the CommServer, since this version can handle a maximum of 50 terminals.
Message Size Textbox
Message Size:
Values:
32 - 380
Default:
100
This textbox allows the user to specify the size of the largest single message (in number of characters) that can be passed to a terminal. Longer messages are broken into several packets.
Notes:
1. This parameter only applies when the CommServer is using the cellular
polling protocol (the Use Cellular Protocol checkbox in the Com-
mServer’s Radio Link Features screen has been checked).
2. In systems using the Wireless LAN protocol, the maximum value for this parameter is 380. In systems using the polling protocol, the maximum value is 116.
Psion Teklogix 9500 Communications Server User Manual
C-137
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The Base Station Screens
Auto-Startup Checkbox
Auto-Startup:
Values:
<selected>, <unselected>
Default:
<selected>
If this checkbox is selected, the CommServer will command the base station to start polling after the CommServer is turned on.
Note:
If the CommServer is being configured as a slave controller, the “Auto Startup” parameter should be disabled.
Delete Button
Delete
The Delete button allows the user to delete the currently-displayed base station connection. When it is pressed, the CommServer displays a confirmation screen:
If the user presses the Cancel button on this screen, the CommServer displays the
Configure Existing Base Station screen again. If the user presses the OK button, the
CommServer removes the interface’s data from the configuration cache and displays a confirmation screen:
When the user presses the OK button in this confirmation screen, the CommServer displays the Configuration Main Menu. The choice for the deleted base station connection is no longer present in the Base Stations listbox.
C-138
Psion Teklogix 9500 Communications Server User Manual
C.2.3.4 Connectivity Options
T
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The Base Station Screens
1
2
The CommServer displays the Connectivity Options screen after the user has selected pressed the Connectivity Options button.
IP Address and Port Textboxes
IP Address:
:
Values:
<see text>
Default:
IP Address: <none>; Port: 16100
These textboxes allow the user to enter an IP address and port number for the base station. The IP address may be any valid IP address; the port number can range from
1024 to 32767.
Psion Teklogix 9500 Communications Server User Manual
C-139
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
T
C.2.4 CommServer Configuration: The RRM Groups Screens
RRM Groups:
Configure
RRM Groups listbox on Configuration Main Menu:
[1] Example Group
Configure
[#] Create New
[1] Example Group
Configure New RRM Group
RRM Groups Menu
The RRM Groups screens of the CommServer are accessible from the RRM Groups listbox and selection button.
The RRMs in each group transmit on the same frequency alternately. The CommServer coordinates the transmissions so that no RRMs transmit at the same time. This is different from base stations, where the timing of the radio transmissions is controlled
only by the base stations themselves. See “CommServer Configuration: The Base
Station Screens” on page E-132 for more information on configuring base stations.
To add RRMs, first create a new RRM group through the Configure New RRM Group
1. Select the Create New option from the RRM Groups dropdown menu.
2. Press the Configure button. The Configure New RRM Group screen
3. Fill in the parameters for the new RRM group.
4. Press the OK button. The Confirmation screen appears.
5. Press the OK button. The Main Menu screen appears again.
Next, add individual RRMs to the newly-created group:
6. Select the RRM group from the RRM Groups dropdown menu. Press
the Configure button. The Configure New RRM Group screen (page C-
C-140
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
7. Press the Configure button. The RRM Group Menu screen (page C-
8. Select the Create New option from the RRMs dropdown menu.
9. Press the Configure button. The Configure New RRM screen (page C-
10. Fill in the parameters for the new RRM.
11. Press the OK button. The Confirmation screen appears.
12. Press the OK button. The RRM Group Menu screen appears again.
At this point more RRMs can be added to the group.To add another RRM group, return to the main menu and select the Create New option from the RRM Groups dropdown menu again.
RRM groups and RRMs use narrowband FM radio. The performance of such groups depends critically on the radio parameters, and these interact complexly. Psion Teklogix provides a parameter-analysis utility to help the adiminstrator set up the groups. This
utility is described in Section C.2.4.6, “Analyze RRM Group” (see page C-156).
Psion Teklogix 9500 Communications Server User Manual
C-141
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
C.2.4.1 Configure New RRM Group
1
2
In this screen, the user can set options for a new RRM group.
C-142
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
All of the RRMs in a group operate on the same frequency. If there is more than one
RRM in the group, the CommServer causes them to transmit alternately.
Each RRM must be a member of an RRM group; there may be more than one RRM group configured in the CommServer. An RRM group may contain only one RRM, and may contain a maximum of four RRMs.
Name Textbox
Name:
Values:
<any text string>
Default:
Unnamed RRM Group
This textbox allows the user to enter a name for the new RRM group.
Protocol Listbox
Type:
Values:
TCP/IP
Default:
TCP/IP
This listbox allows the user to select the protocol to be used for the connection to this
RRM group. Currently, the TCP/IP protocol is available.
Enabled Checkbox
Enabled:
Values:
<enabled>, <disabled>
Default:
<enabled>
If this parameter is enabled, the CommServer uses the RRMs in this group.
Psion Teklogix 9500 Communications Server User Manual
C-143
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
Auto Startup Checkbox
Auto Startup:
Values:
<enabled>, <disabled>
Default:
<enabled>
If this parameter is enabled, the CommServer establishes communication with the
RRMs in this RRM group when it boots, and starts polling automatically.
If this parameter is disabled, the CommServer establishes communication with the
RRMs in this group when it boots, but does not start polling in this RRM group until a start polling message (0S) is received from the host.
Polling starts if at least one of the RRMs in the RRM group is operating when the CommServer boots.
Polling Protocol Parameters
Number of Poll Windows Textbox
Number of Poll Windows:
Values:
2 - 4
Default:
3
This textbox allows the user to specify the number of poll windows in which the RRM listens for terminal responses after sending a poll.
Warning: THIS PARAMETER IS PRE-CONFIGURED FOR YOUR
SYSTEM, AND SHOULD NOT BE CHANGED without a proper understanding of how it affects the radio link!
Size of Poll Windows Textbox
Size of Poll Windows:
Values:
5 - 32
Default:
8
This textbox allows the user to specify the size of the poll windows in which the RRMs of this RRM group listen for terminal replies.
C-144
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
Warning: THIS PARAMETER IS PRE-CONFIGURED FOR YOUR
SYSTEM, AND SHOULD NOT BE CHANGED without a proper understanding of how it affects the radio link!
Maximum Message Segment Size Textbox
Maximum Message Segment Size:
Values:
32 - 116
Default:
100
This textbox allows the user to specify the size of the largest message segment, in bytes, that will be sent over the Psion Teklogix radio network. Larger messages are broken into parts.
Warning: THIS PARAMETER IS PRE-CONFIGURED FOR YOUR
SYSTEM, AND SHOULD NOT BE CHANGED without a proper understanding of how it affects the radio link!
Number of Retries Textbox
Number of Retries:
Values:
1 - 7
Default:
3
This textbox allows the user to specify the number of times the RRM retransmits a message to a terminal, after receiving no acknowledgement from the terminal, before it declares the terminal offline.
Collision Size Textbox
Collision Size:
Values:
3 - 10
Default:
6
This textbox allows the user to specify the smallest number of characters of noise received by the RRM, that will be interpreted as interfering transmissions from Psion
Teklogix equipment. When this threshold is exceeded, the RRM starts collision resolution.
Psion Teklogix 9500 Communications Server User Manual
C-145
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
Warning: THIS PARAMETER IS PRE-CONFIGURED FOR YOUR
SYSTEM, AND SHOULD NOT BE CHANGED without a proper understanding of how it affects the radio link!
Free Window Factor Textbox
Free Window Factor:
Values:
0 - 7
Default:
0
This textbox allows the user to specify the probability that the RRM will include a free window in its poll, during which any terminal may transmit.
Warning: THIS PARAMETER IS PRE-CONFIGURED FOR YOUR
SYSTEM, AND SHOULD NOT BE CHANGED without a proper understanding of how it affects the radio link!
Message Mode Limit Textbox
Message Mode Limit:
Values:
0 - 7
Default:
4
This textbox allows the user to specify the probability of including a message-mode poll in its poll transmission.
Warning: THIS PARAMETER IS PRE-CONFIGURED FOR YOUR
SYSTEM, AND SHOULD NOT BE CHANGED without a proper understanding of how it affects the radio link!
Callsign Period Textbox
Callsign Period:
Values:
0 - 60
Default:
0
C-146
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
This textbox allows the user to specify the amount of time between transmissions of the callsign. This parameter is in minutes. A value of 0 (zero) indicates that no callsign is transmitted.
Callsign Text Textbox
Callsign Text:
Values:
<text>
Default:
Teklogix
This textbox allows the user to specify the text to be transmitted as the RRM’s callsign.
The text is transmitted as Morse code.
Radio Parameters
Because some of the radio parameters are identical for a given group of timeplexed
RRMs, they may be configured by the user once on the CommServer; the CommServer then passes them to the RRMs in the group. These parameters include the synchronization delay (Sync Delay), the remote transmit on-time (Remote TxOn), the channel number to be used (Active Channel), and the size of the poll header.
Although the TRX7370 narrow band FM radio in each RRM in the group is configured separately, the CommServer assumes that they will be configured the same. To ensure this, the CommServer looks at certain parameters returned by each of the RRMs. These parameters include the radio baud rate and the transmit-on time.
These parameters are compared against the values returned by other RRMs within the same group. Error messages are displayed should these values not match, but the worstcase value is then chosen for use.
Warning: THE RADIO PARAMETERS ARE PRE-CONFIGURED FOR
YOUR SYSTEM, AND SHOULD NOT BE CHANGED without a proper understanding of how it affects the radio link!
Sync Delay Textbox
Sync Delay:
Values:
3 - 45
Default:
28
Psion Teklogix 9500 Communications Server User Manual
C-147
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
This textbox allows the user to specify the number of delay characters inserted between the RRM’s transmission and the first response window.
Remote TxOn Textbox
Remote TxOn:
Values:
3 - 60
Default:
13
This textbox allows the user to specify the number of fill characters sent by the terminals to their radios before the terminals send message data.
Active Channel Textbox
Active Channel:
Values:
1 - 20
Default:
1
This textbox allows the user to specify the radio channel to be used by all the RRMs in the RRM group.
Group Parameters
Group Textboxes
Group 1:
Group 2:
Values:
<see text>
Default:
<none>
These textboxes allow the user to specify RRM subgroups.
If the coverage areas of two or more of the RRMs in this RRM group do not overlapping, the non-overlapping RRMs may be assigned to the same subgroup. They will then poll at the same time. This improves system response time and reduces the amount of signalling on the network.
As an example, if the RRM group has 3 RRMs, and RRMs 1 and 3 don't overlap, RRMs
1 and 3 may be placed in one subgroup. They will then poll simultaneously. RRM 2 may be placed in another subgroup. Polling then alternates between the two subgroups.
C-148
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
To configure a subgroup, place the numbers of the RRMs in the textbox for that subgroup. The numbers correspond to the numbers of the RRMs named in the RRM list
on the RRM Group Menu (see page C-149). For instance, “13” in the textbox for
subgroup 1 places RRMs 1 and 3 in that subgroup.
RRMs that are not assigned to subgroups poll individually, after all of the RRMs in the subgroups poll.
C.2.4.2 The RRM Group Menu
1
2
When the user chooses an existing RRM group from the RRM Groups listbox and then presses the Configure button, the CommServer displays the RRM Group Menu.
The RRM Group Menu has two Configure buttons, which are located next to the following text:
• General Options
When the user presses this Configure button, the CommServer displays the
Configure Existing RRM Group screen.
Psion Teklogix 9500 Communications Server User Manual
C-149
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
•
RRMs
RRM Groups:
Configure
When the user selects the name of an existing RRM from the listbox, then presses this Configure button, the CommServer displays the RRM Options screen for that RRM.
RRM Groups listbox on Configuration Main Menu:
[1] Example Group
Configure
[#] Create New
[1] Example RRM
Configure New RRM
RRM Menu
The RRM Groups screens of the CommServer are accessible from the RRM
Groups listbox and selection button.
There is also a selection in the listbox, Create New, for adding a new RRM.
There is also an Analyze button:
Analyze
When the user presses the Analyze button, the CommServer displays a screen listing
parameters for the RRM system. See “Analyze RRM Group” on page C-156.
At the bottom, there is a Main Menu button. When the user presses the Main Menu button, the CommServer displays the Configuration Main Menu.
C-150
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
C.2.4.3 Configure Existing RRM Group
1
2
Psion Teklogix 9500 Communications Server User Manual
C-151
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
In this screen, the user can select general options for this RRM group.
The options in this screen are the same as the options in the Create New RRM Group
screen (see “Configure New RRM Group” on page C-142).
There is also a Delete button:
Delete Button
Delete
The Delete button allows the user to delete the currently-displayed RRM group. When it is pressed, the CommServer displays a confirmation screen:
If the user presses the Cancel button on this screen, the CommServer displays the
Configure RRM Group screen again. If the user presses the OK button, the CommServer removes the RRM group’s data from the configuration cache and displays a confirmation screen:
When the user presses the OK button in this confirmation screen, the CommServer displays the Configuration Main Menu. The choice for the deleted RRM connection is no longer present in the Configure RRM Group listbox.
C-152
Psion Teklogix 9500 Communications Server User Manual
C.2.4.4 Configure New RRM
T
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
1
2
The CommServer displays this Configure RRM screen after the user has selected an existing RRM and pressed the Configure button.
Name Textbox
Values:
<see text>
Default:
Unnamed RRM
This textbox allows the user to enter a name for the new RRM.
IP Address And Port Textboxes
IP Address:
:
Values:
<see text>
Default:
IP Address: <none>; Port: 16132
These textboxes allow the user to enter the IP address and port number of the new RRM.
The IP address may be any valid IP address; the port number can range from 1024 to
32767.
Note:
The 9150 must be in RRM mode, and must have the same port number configured. It listens to this port for incoming data from the CommServer, which includes the CommServer’s IP address.
Psion Teklogix 9500 Communications Server User Manual
C-153
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
C.2.4.5 Configure Existing RRM
T
1
2
The CommServer displays this Configure Existing RRM screen after the user has selected an existing RRM from the listbox and pressed the Configure button.
Name Textbox
Values:
<see text>
Default:
Unnamed RRM
This textbox allows the user to enter a name for the RRM.
IP Address And Port Textboxes
IP Address:
:
Values:
<see text>
Default:
IP Address: <none>; Port: 16132
These textboxes allow the user to enter the IP address and port number of the RRM. The
IP address may be any valid IP address; the port number can range from 1024 to 32767.
Note:
The 9150 must be in RRM mode, and must have the same port number configured. It listens to this port for incoming data from the CommServer, which includes the CommServer’s IP address.
C-154
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
Delete Button
Delete
The Delete button allows the user to delete the RRM. When it is pressed, the
CommServer displays a confirmation screen:
If the user presses the Cancel button on this screen, the CommServer displays the
Configure Existing RRM screen again. If the user presses the OK button, the
CommServer removes the RRM’s data from the configuration cache and displays a confirmation screen:
When the user presses the OK button in this confirmation screen, the CommServer displays the RRM Group Menu. The choice for the deleted RRM is no longer present in the RRMs listbox.
Psion Teklogix 9500 Communications Server User Manual
C-155
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
C.2.4.6 Analyze RRM Group
T
1
2
C-156
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
The CommServer displays this Analyze RRM Group screen after the user has pressed the Analyze button. This screen is created by the CommServer after it analyzes the current RRM configuration.
This screen presents the configured parameters for the RRM groups on this
CommServer. It is divided into several parts:
General Parameters
This section gives the name of the RRM group, and lists the protocol it uses.
Polling Protocol Parameters
This section lists the configured parameters for the polling protocol:. These parameters include:
• Number of Poll Windows
• Size of Poll Windows
• Maximum Message Segment Size
• Free Window Factor
• Message Mode Limit
See “Polling Protocol Parameters” on page C-144 for descriptions and possible ranges for these parameters.
Radio Parameters
This section lists the configured parameters for the RRM groups’ radios. All RRMs in the group use the same radio configuration; however, the actual radio hardware in the bases and terminals may differ. These radio parameters include:
• Sync Delay
• Remote TxOn
•
Baud Rate
This changeable parameter indicates the selected bit rate for the radios used in this RRM group.
•
Modulation
This changeable parameter indicates the type of narrow-band FM modulation used by the radios in this RRM group. All radios oin the group must use the
Psion Teklogix 9500 Communications Server User Manual
C-157
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
same modulation. Available modulations include “two-level” and “four-level”.
Not all radios support all modulations; in particular, older radios only support the two-level modulation.
Two-level modulation supports bit rates of 4800 and 9600 bits per second.
Four-levelmodulation supports bit rates of 9600 and 19 200 bits per second.
The analyzer constrains the available bit rates to those supported by the selected modulation.
•
RRM Radios
This parameter ndicates the type of radios installed in the RRMs.
•
Terminal Radios
This changeable parameter indicates the type of radios installed in the terminals with which the RRMs will be communicating.
See “Radio Parameters” on page C-147 for descriptions and possible ranges for these
parameters.
Group Parameters:
This section lists which RRMs belong to which RRM group.
• Combination 1
• Combination 2
C-158
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: The RRM Groups Screens
Results:
This section lists the results of the analysis.
•
Errors
This section lists problems which will cause this RRM-group configuration to not work.
•
Warnings
This section lists less-serious problems than the Errors section. This RRMgroup configuration will work, but it is not optimal.
•
Number of RRMs
The number of RRMs in this group.
•
RRM Combination Cycle
This parameter shows the polling arrangement of the RRMs.
•
Poll Timeout in Terminals (average load),
Poll Timeout in Terminals (maximum load)
These two parameters show how the RRMs will perform under differing loads.
Psion Teklogix 9500 Communications Server User Manual
C-159
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: Radio Link Features
C.2.5 CommServer Configuration: Radio Link Features
T
1
2
Operate In Cellular Mode Checkbox
Operate in Cellular Mode:
Values:
<selected>, <unselected>
Default:
<selected>
C-160
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: Radio Link Features
If this checkbox is selected, the base stations connected to this CommServer operate in cellular mode, enabling terminals to move seamlessly between base stations, switching channels if necessary.
Poll ID Textbox
Poll ID:
Values:
0 - 15
Default:
0
The poll ID is a unique number for this CommServer. It is used in the poll header to identify the CommServer when it polls terminals. This is useful in systems with more than one CommServer.
Polling Protocol Terminal Timeout Textbox
Polling Protocol Terminal Timeout:
Values:
0 - 60
Default:
60
This parameter specifies the time (in minutes) that a terminal is allowed to be offline before the CommServer removes it from the system. When the terminal resumes activity, it sends a “warm initialization” message to the CommServer to re-establish communication.
This parameter is related to the Percent Polling Protocol Terminal Timeout parameter below; it is used in systems with network timeplexing and RRMs.
Percent Polling Protocol Terminal Timeout Textbox
Percent Polling Protocol Terminal Timeout:
Values:
50 - 90
Default:
75
This parameter specifies the time that a terminal is allowed to be inactive before the
CommServer declares it offline. This time is expressed as a percentage of the Polling
Protocol Terminal Timeout parameter above. Thus, if the Timeout parameter is 60 and this parameter is 75, the CommServer declares a terminal offline after 45 minutes of inactivity (45 minutes is 75 percent of 60 minutes).
Psion Teklogix 9500 Communications Server User Manual
C-161
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: Radio Link Features
An offline terminal is still considered part of the Psion Teklogix system; messages to it are queued at the CommServer. In this example, the terminal remains offline until it notifies the CommServer that it is online, or until the CommServer removes it from the system entirely, after 60 minutes of inactivity.
This parameter is used in systems with network timeplexing and RRMs.
Direct TCP Connections For TekTerm Checkbox
Direct TCP Connections for TekTerm:
Values:
<selected>, <unselected>
Default:
<selected>
If this checkbox is selected, terminals using TekTerm (such as the 7035, 8255, and
8260) on the TCP/IP network may connect directly to the CommServer through access points such as the Psion Teklogix 9150.
Direct TCP Check Duplicate Terminal Number Checkbox
Direct TCP Check Duplicate Terminal Number:
Values:
<selected>, <unselected>
Default:
<selected>
If this checkbox is selected, the Communication Server will check for duplicate terminal numbers among those terminals connecting by Direct TCP if the auto-terminal ID feature is enabled.
Expiration period... Textbox
Expiration period (in days) for Automatic Radio Address and Terminal Number:
Values:
50 - 90
Default:
75
This parameter specifies the amount of time before automatically-assigned rado addresses and terminal numbers expire.
C-162
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: Radio Link Features
Automatic Radio Address Textboxes
Automatic Radio Address assignment range:
...
Values (lower, upper):
0 - 3840, 0 - 3840
Default (lower, upper):
1024, 2084
The Automatic Radio Address textboxes specify the lower and upper allowed values of radio addresses that will be assigned automatically to terminals when the Remote
Sockets feature is used.
Note:
This parameter has a upper value of 50 on the Model S900L software-only version of the CommServer, since this version can handle a maximum of 50 terminals. The defaults are 1 and 50 respectively in this case.
Important:
A range of 0 ... 0 signifies that this feature is disabled.
Do not configure a range starting with zero and ending with a number greater than zero.
Automatic Terminal Number Assignment Textboxes
Terminal numbers may be assigned automatically to up to five groups of terminals.
These groups are listed in this section, starting with Group 1, the default group. Each group has the following parameters:
Range:
...
Values (lower, upper):
0 - 3840, 0 - 3840
Default (lower, upper):
0, 0
Comment:
The Range parameter specifies specify the lower and upper allowed values of terminal numbers that will be assigned automatically to terminals in the group. The Comment parameter allows the administrator to add a note about the group.
Note:
This parameter has a upper value of 50 on the Model S900L software-only version of the CommServer, since this version of the software can handle a maximum of 50 terminals.
Important:
A range of 0 ... 0 signifies that this feature is disabled.
Do not configure a range starting with zero and ending with a number greater than zero.
Psion Teklogix 9500 Communications Server User Manual
C-163
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: Radio Link Features
Help Button
Help
The Help button links to a help screen that clarifies the use of the Automatic Terminal
Number Assignment feature.
Notes:
T
1. The terminal numbers configured through the Terminal Range parameters for each host emulation must be within this range if that host is to use automatically-assigned terminal numbers.
2. The Total Number of Terminals parameter in the Miscellaneous System
Options screen must be larger than the highest upper value (in any group) of this parameter.
3. Terminals not assigned to a group will poll after those in groups.
C-164
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: 802.IQ v1 And v2 Features
C.2.6 CommServer Configuration: 802.IQ v1 And v2 Features
1
2
802.IQ v1/v2 Common Features
Auto Startup Checkbox
Auto Startup:
Values:
<selected>, <unselected>
Default:
<unselected>
Psion Teklogix 9500 Communications Server User Manual
C-165
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: 802.IQ v1 And v2 Features
When checked, this parameter enables the Psion Teklogix’ 802.IQ protocol (v1 or v2) to start automatically when the CommServer is rebooted.
Terminal Offline Timeout Textbox
Terminal Offline Timeout:
Values:
1 - 240
Default:
5
This parameter sets the time (in minutes) before the 9500 will declare an 802.IQ terminal offline.
Beacon Period Textbox
Beacon Period:
Values:
1 - 20
Default:
2
This parameter sets the duration (in seconds) of a beacon.
802.IQ v1 Features
Enabled Checkbox
Enabled:
Values:
<selected>, <unselected>
Default:
<unselected>
When checked, this parameter enables 802.IQ v1.
Beacon Gateway Interface Listbox
Beacon Gateway Interface: [Configured: [0] Ethernet]
Values:
<index> Ethernet <MAC address>
Default:
[0] Ethernet <MAC address>
This parameter specifies the physical network interface through which the CommServer will send 802.IQ v1 beacon packets. (The CommServer may have up to two Ethernet interfaces.) The interface is identified by its index number and MAC address.
C-166
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
CommServer Configuration: 802.IQ v1 And v2 Features
802.IQ v2 Features
Protocol Type ID Textbox
Protocol Type ID:
Values:
5001 - 65535
Default:
2476
This parameter sets the protocol type ID which which the CommServer will label
802.IQ v1 beacon packets.
802.IQ v2 Features
Enabled Checkbox
Enabled:
Values:
<selected>, <unselected>
Default:
<unselected>
When checked, this parameter enables 802.IQ v2.
An 802.IQ v2 beacon is a broadcast sent out to all 802.IQ v2-enabled terminals. It allows the 802.IQ v2 terminals to detect the CommServer and obtain the CommServer’s
IP address.
The beacon allows terminals to determine when they have roamed between base stations. It also enables a terminal to determine whether the base station or CommServer was rebooted, and if so, how to recover.
Beacon UDP Port Textbox
Beacon UDP port:
Values:
5001 - 65535
Default:
8888
This parameter sets the port number through which the CommServer will send beacon packets.
Beacon Gateway Interface Listbox
Beacon Gateway Interface: [Configured: [0] Ethernet (IP Address)]
Values:
<index> Ethernet <IP Address>
Default:
[0] Ethernet <IP Address>
Psion Teklogix 9500 Communications Server User Manual
C-167
Appendix C: The 9500 CommServer’s Web Interface
Redundancy Options
802.IQ v2 Features
This parameter specifies the physical network interface through which the CommServer will send 802.IQ v2 beacon packets. (The CommServer may have up to two Ethernet interfaces.) The interface is identified by its index number and IP address.
C.2.7 Redundancy Options
1
2
In this screen, the user can set various options for redundant operation of the
CommServer.
This feature enables two similarly-configured CommServers to operate in parallel. One
CommServer is designated as the primary CommServer, and manages communication to the rest of the Psion Teklogix system. The other CommServer is designated as the
secondary CommServer, and remains idle. Both CommServers communicate with an
arbiter, another node which serves as a reference on the network.
C-168
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Redundancy Options
802.IQ v2 Features
Both of the CommServers must be connected to the network, and each CommServer is aware of the other’s IP address. The secondary CommServer polls the primary
CommServer, and the primary CommServer responds, exchanging information about their status. There may not be more than one secondary CommServer.
If the secondary CommServer cannot communicate with the primary CommServer, but can communicate with the arbiter, it assumes that the primary CommServer is not working, becomes primary, and assumes control of the Psion Teklogix network.
When the first CommServer comes online again, it assumes secondary status; the second CommServer continues as the primary.
If the CommServers cannot communicate with the arbiter, they assume that the network is not working.
Note:
When control of the Psion Teklogix system is passed from one CommServer to the other CommServer, sessions between hosts and terminals are closed, and terminals and bases are reset.
Both CommServers must be configured identically, with the exception of their own IP addresses, and the Backup IP Address parameter (the address of the other
CommServer).
Important:
The ‘TCP Direct Connections To Host’ parameter must be enabled for Redundancy to work. This parameter can be found on the Radio
Link Features screen.
Enabled Checkbox
Enabled:
Values:
<selected>, <unselected>
Default:
<unselected>
When this checkbox is selected, the CommServer uses the Redundancy feature. A second CommServer (appropriately configured) and an arbiter must be present on the network for the feature to operate properly.
Preferred Primary Checkbox
Preferred Primary:
Values:
<selected>, <unselected>
Default:
<selected>
Psion Teklogix 9500 Communications Server User Manual
C-169
Appendix C: The 9500 CommServer’s Web Interface
Redundancy Options
802.IQ v2 Features
This checkbox indicates whether this CommServer is the preferred primary
CommServer.
Backup IP Address Checkbox
Backup IP Address:
Values:
<any valid IP address>
Default:
0.0.0.0
This parameter contains the address of the other CommServer with which this
CommServer communicates.
Alias IP Address Textbox
Alias IP Address:
Values:
<any valid IP address>
Default:
0.0.0.0
This parameter contains the alias IP address for this CommServer and the other
CommServer in the redundancy system. This address must be the same on both the primary and secondary CommServers.
Devices on the network may have more than one IP address corresponding to their network interface (and hardware address). The primary CommServer presents the alias address to the network as well as its own unique IP address. The secondary
CommServer only presents its own unique IP address to the network.
When the secondary CommServer becomes the primary, it starts to use the alias IP address. The old primary CommServer, which becomes the secondary, stops using the alias IP address.
Devices on the network which communicate directly with the Psion Teklogix network
CommServer’s IP address, such as terminals using Direct TCP, may communicate with the alias IP address. They will then communicate with whichever of the two redundant
CommServers is the primary.
The TCP Direct Connections To Host check-box in the Radio Link Features screen must be checked in this case.
C-170
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Redundancy Options
802.IQ v2 Features
Interface Number Listbox
[0] Ethernet. Change to:
Values:
<indexes and IP addresses of currently-installled interfaces>
Default:
<index 0 and IP address of interface 0>
This listbox allows the user to specify the interface number through which this 9500 communicates with the other 9500, if redundancy is used.
Arbiter IP Address Textbox
Arbiter IP Address:
Values:
<any valid IP address>
Default:
0.0.0.0
This parameter contains the address of a device on the network which is known to be reliable. Both CommServers ping this device; if they receive no reply, they assume that the network is not operating.
This address should be the same on both the primary and secondary CommServers.
Poll Interval, Poll Timeout, And Poll Tries Textboxes
Poll Interval:
Values:
1 - 1000
Default:
10
Poll Timeout:
Values:
1 - 10
Default:
2
Poll Tries:
Values:
2 - 7
Default:
3
These three parameters, Poll Interval, Poll Timeout, and Poll Tries, are closely related.
Psion Teklogix 9500 Communications Server User Manual
C-171
Appendix C: The 9500 CommServer’s Web Interface
System Configuration: SNA Parameters
802.IQ v2 Features
This CommServer, when acting as the secondary CommServer, polls the primary
CommServer at intervals specified by the Poll Interval parameter.
After each poll, this CommServer waits for a reply. It waits for a time specified by the
Poll Timeout parameter. If there is no reply during this interval, the CommServer sends another poll to the other CommServer.
The total number of polls sent while this CommServer waits for the other CommServer to respond is specified by the Poll Tries parameter.
If no response is received to any of the polls, this CommServer then pings the arbiter. If the CommServer receives a ping reply from the arbiter, but cannot contact the other
CommServer, it assumes that the other CommServer is off the network, becomes primary, and takes control of the Psion Teklogix system.
If this CommServer cannot reach the other CommServer or the arbiter, it assumes that the network is not working, and remains in secondary mode.
C.2.8 System Configuration: SNA Parameters
1
2
In this screen, the user can set an option for the CommServer’s SNA operation.
Note:
Most of the SNA options in the CommServer are set through the IBM Personal Communications software.
Network Name Textbox
Network Name:
Values:
<see text>
Default:
APPN
C-172
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
System Configuration: The Users Screens
802.IQ v2 Features
This textbox contains the name of the SNA network to which the host and the
CommServer are connected.
The network name is a maximum of eight alphanumeric ASCII characters, beginning with a letter. If less than eight characters, it is padded to eight characters with spaces at the right.
C.2.9 System Configuration: The Users Screens
Users listbox on Configuration Main Menu:
[1] sue
Configure
[#] Create New
[1] sue
[2] nick
Create New User Entry
Edit Existing User Entry
The user administration screens of the CommServer are accessible from the Users listbox and selection button.
C.2.9.1 Create New User Entry
1
2
In this screen, the user can set options for a new user.
Psion Teklogix 9500 Communications Server User Manual
C-173
Appendix C: The 9500 CommServer’s Web Interface
System Configuration: The Users Screens
802.IQ v2 Features
Name Textbox
Name:
Values:
<see text>
Default:
<none>
This textbox allows the entry of a name for the user. The name must be an ASCII string.
Password Textbox
Password:
Values:
<see text>
Default:
<none>
This textbox allows the entry of a password for this user. The password must be an
ASCII string, and may be up to 32 characters long.
This password is case-sensitive: the CommServer recognizes differences in case when checking it. The password EXAMPLE is considered to be different than passwords
example or EXamPLe.
Note:
The password is displayed in cleartext on this screen.
C.2.9.2 Edit Existing User Entry
1 2
In this screen, the user can set options for an existing user.
C-174
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
System Configuration: The Users Screens
802.IQ v2 Features
Name Textbox
Name:
Values:
<see text>
Default:
<none>
This textbox allows the entry of a new name for this existing user. The name must be an
ASCII string, and may be up to 32 characters long. This name is not case-sensitive.
Password Textbox
Password:
Values:
<see text>
Default:
<none>
This textbox allows the entry of a new password for this existing user. The password must be an ASCII string, and may be up to 32 characters long.
This password is case-sensitive: the CommServer recognizes differences in case when checking it. The password EXAMPLE is considered to be different than passwords
example or EXamPLe.
Note:
The password is displayed in cleartext on this screen.
Delete Button
Delete
The Delete button allows the user to delete the currently-displayed user from the list of users. When it is pressed, the CommServer displays a confirmation screen:
If the user presses the Cancel button on this screen, the CommServer displays the Edit
Existing User Entry screen again.
Psion Teklogix 9500 Communications Server User Manual
C-175
Appendix C: The 9500 CommServer’s Web Interface
System Configuration: SNMP Parameters
802.IQ v2 Features
If the user presses the OK button on this screen, the CommServer removes the user’s data from the configuration cache and displays a confirmation screen:
When the user presses the OK button in this confirmation screen, the CommServer displays the Configuration Main Menu again. The choice for the deleted user entry is no longer present in the Users listbox.
C.2.10 System Configuration: SNMP Parameters
1
2
In this screen, the user can set an option for the CommServer’s SNMP operation. Most of the SNMP options in the CommServer are set through the operating-system software.
Proxy Throttling For Non-IP Terminals Listbox
Proxt throttling for non-IP terminals:
Values:
disabled, 500b/s, 1000b/s, 1500 b/s
Default:
disabled
C-176
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
System Configuration: Miscellaneous System Options
802.IQ v2 Features
This textbox allows the user to enable ‘throttling’ for SNMP queries and responses crossing Psion-Teklogix-proprietary radio networks. Since these networks often use narrowband FM transmissions, their maximum data rates may not be as high as those of
802.11 networks. Some SNMP queries may result in large amounts of data crossing the
RF networks; the Proxy Throttling parameter limits the rate at which such data may be sent, to prevent saturation of the RF network.
C.2.11 System Configuration: Miscellaneous System Options
1
2
In this screen, the user can set miscellaneous system options for the CommServer.
Serial Number Textbox
Serial Number:
Values:
<see text>
Default:
0
This textbox allows the user to enter a serial number for this CommServer.
Psion Teklogix 9500 Communications Server User Manual
C-177
Appendix C: The 9500 CommServer’s Web Interface
System Configuration: Miscellaneous System Options
802.IQ v2 Features
Enable Telnet Authorization Checkbox
Enable Telnet Authorization:
Values:
<enabled>, <disabled>
Default:
<disabled>
When this parameter is enabled, the CommServer requests a username and password from telnet sessions connecting to the network console.
When a session connects, the CommServer requests a username:
>User:
After the user enters a username, the CommServer requests a password:
>User: sue
>Password:
>
After the user enters the correct password, the CommServer displays the network-console prompt:
>User: sue
>Password: ********
>User Logged In
>
If the user does not enter a correct username and password, the CommServer displays the message
Unknown Name or Password
and requests another username.
The user names and passwords are those listed in the Users listbox in the CommServer’s
Main Configuration Screen and set in the Create New User and Edit Existing User screens. They are the same ones used to log into the CommServer’s web interface.
C-178
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Miscellaneous Commands
802.IQ v2 Features
C.2.12 Miscellaneous Commands
C.2.12.1 Display Entire Database Contents
1
2
In this screen, the CommServer displays the contents of its configuration database. This is the permanent database with which the CommServer booted. Changes made to the configuration database are stored in a configuration cache, which must be saved before the CommServer can use the changes. Not all of the screen is shown here.
Psion Teklogix 9500 Communications Server User Manual
C-179
Appendix C: The 9500 CommServer’s Web Interface
Miscellaneous Commands
802.IQ v2 Features
C.2.12.2 Restart The CommServer Software
When the user presses the Restart button, the CommServer displays the Restart
Controller Software screen:
1
2
OK Button
OK
When the user presses the OK button, the CommServer displays the Restarting
Confirmation screen and then restarts the Psion Teklogix software inside the
CommServer. This restart is not an operating-system reboot.
The Restarting Confirmation Screen
The CommServer sends this screen to the browser, then restarts the Psion Teklogix
Communications Server software. Restarting takes approximately 5 minutes.
OK Button
OK
After the CommServer has rebooted, pressing the OK button in this screen causes the
CommServer to display the Main Configuration Screen.
C-180
Psion Teklogix 9500 Communications Server User Manual
Appendix C: The 9500 CommServer’s Web Interface
Miscellaneous Commands
802.IQ v2 Features
C.2.12.3 Validate and Save Database Contents
When the Validate button in the Configuration Main Menu is pressed, the CommServer checks the configuration database cache for errors, then displays the Database
Validation Results screen:
1 2
Any errors in the configuration are displayed in this screen.
Commit Button
Commit
When the user presses the Commit button, the CommServer writes the validated contents of its configuration cache to the permanent configuration store.
Note:
Once a configuration has been committed, the CommServer’s internal software must be updated before the CommServer will run with the new configuration. To update the software,press the Restart button on the Main Screen.
Undo Button
Undo
When the user presses the Undo button, the CommServer restores the last committed version of its configuration.
Psion Teklogix 9500 Communications Server User Manual
C-181
Appendix C: The 9500 CommServer’s Web Interface
Miscellaneous Commands
802.IQ v2 Features
Warning: All changes made to the configuration of the CommServer since the last configuration was committed are lost.
Cancel Button
OK
When the user presses the Cancel button, the CommServer displays the Configuration
Main Menu. Changes remain in the temporary configuration cache.
C-182
Psion Teklogix 9500 Communications Server User Manual
A
PPENDIX
D
EVELOPING
HTML F
OR
T
HE
C
OMM
S
ERVER
D
D.1 Limitations Of The CommServer’s HTML/TESS Emulation D-3
D.2 Supported HTML Tags . . . . . . . . . . . . . . . . . . . . D-4
D.2.1 Link, Miscellaneous, And Input Tags . . . . . . . D-5
D.2.2 Text Attribute Tags . . . . . . . . . . . . . . . . . D-7
D.2.3 Text Formatting Tags . . . . . . . . . . . . . . . . D-8
D.2.4 Table, List and Definition Tags. . . . . . . . . . . D-9
D.3 Function Keys . . . . . . . . . . . . . . . . . . . . . . . . . D-11
D.3.1 Mapping The Function Keys . . . . . . . . . . . . D-11
D.3.2 Tags Without Function-Key Support. . . . . . . . D-12
D.3.3 Predefined Function Keys . . . . . . . . . . . . . D-12
D.3.4 Remapping Function-Key Zero (F0) . . . . . . . . D-13
D.4 HTML Extensions For TESS . . . . . . . . . . . . . . . . . D-14
D.5 Debugging And Testing With TekHTML . . . . . . . . . . . D-16
D.6 Cookies . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-19
Psion Teklogix 9500 Communications Server User Manual
D-1
Appendix D: Developing HTML For The CommServer
Limitations Of The CommServer’s HTML/TESS Emulation
D.1 Limitations Of The CommServer’s HTML/TESS Emulation
The CommServer can translate HTTP datastreams and the web pages they transport into TESS for display on Psion Teklogix terminals.
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
PTX
Emulation
Software
Base
ANSI
Terminal
Software
TESS
HTTP
Web
Browser
Terminal
ANSI
TESS
PTX
Handler Software
9500 CommServer
HTTP Server
Host Computer
This emulation can handle HTTP datastreams with the following limitations:
• Graphics, fonts, and stylesheets are not supported.
• Frames are not supported.
• Some HTML tags are not supported (
<LAYER>
,
<MAP>
, etc.).
• Paragraph alignment is not supported.
• HTML pages may not exceed the height of the terminal screen.
The emulator attempts to display such screens, but only the first part of the page is displayed. There is no way to scroll to other parts of the page.
• The emulator uses HTTP 1.0.
• Only
http:// and
file:// access protocols (schemes) are supported.
• Only unencrypted connections are supported.
• User authentication is not supported.
• MIME types sent by the web server are not used.
• Drop-down list boxes, radio buttons, and checkboxes are not supported.
• Advanced features of Web servers (like redirection) are not supported.
Psion Teklogix 9500 Communications Server User Manual
D-3
Appendix D: Developing HTML For The CommServer
Supported HTML Tags
D.2 Supported HTML Tags
The Psion Teklogix HTML emulator accepts the tags described in Section D.2.1 to
Section D.2.4 and uses them to display text. Other tags are unsupported or ignored.
Unsupported Tags
Tags not mentioned in these tables are unsupported by the emulator. When the emulator encounters an unsupported tag, it removes the tag and its corresponding end-tag from the TESS datastream sent to the terminal, but does not remove any text surrounded by the tags.
Thus, HTML source text containing the unsupported tag
<UNKNOWN>
, such as: text, <UNKNOWN>more text,</UNKNOWN> still more text would be rendered on the terminal as: text, more text, still more text
Ignored Tags
The CommServer’s HTML emulator ignores two tags,
<SCRIPT>
and
<STYLE>
.
When it encounters one of these tags, it removes the tag and its associated end-tag from the TESS datastream sent to the terminal, and it also removes the text (and any other tags) surrounded by the
<SCRIPT>
and
<STYLE>
tags.
Thus, HTML source text containing the ignored tag
<SCRIPT>
, such as: text, <SCRIPT>more text,</SCRIPT> still more text would be rendered by TekHTML on the terminal as text, still more text
In this way, TekHTML prevents the text of embedded Javascript and stylesheet information from being passed to the terminals and displayed on their screens.
D-4
Psion Teklogix 9500 Communications Server User Manual
Appendix D: Developing HTML For The CommServer
Link, Miscellaneous, And Input Tags
D.2.1 Link, Miscellaneous, And Input Tags
Tag
<HEAD>
<TITLE>
<BODY>
<TEKLOGIX>
Meaning
Information about page
Title of page
Content of page
Information about output fields
Support Tag-Specific Information
Terminal and console; limited support
This tag is recognized, but no tag attributes are supported. All tags between
<HEAD>
and
</HEAD> except
<TITLE>
are ignored
Terminal and console; limited support
The title is printed at the top of the screen.
Limited support
No attributes of the
<BODY>
tag are recognized. TekHTML for
Windows NT does not recognize Psion Teklogix’
PASSTHRU
,
PASSTHRUPORT
,
PASSTHRUESC
, and
PASSTHRUNEXTPAGE attributes, which are used by the HTML emulation in
Psion Teklogix’ network controllers.
Full support
This tag is Psion Teklogixspecific. It has one attribute,
TEKFLAGS
, and is used for marking text to be treated as TESS output fields.
Psion Teklogix 9500 Communications Server User Manual
D-5
Appendix D: Developing HTML For The CommServer
Link, Miscellaneous, And Input Tags
<A>
<INPUT>
<FORM>
<IMG>
Anchor
Input fields
Input forms
Image
Terminal and console; limited support
Terminal and console; limited support
Terminal and console; limited support
Recognizes the
HREF attribute for hyperlinks. All other attributes, including
NAME, are ignored.
Fully supported input types:
HIDDEN
,
PASS-
WORD
,
SUBMIT
,
TEXT
.
Limited support:
RESET
.
A button with the
RESET attribute does nothing when pressed. The
RADIO
, and
CHECKBOX input types are displayed; there is no support for entry.
Attributes supported:
ACCESSKEY
,
FKEYO-
NENTER
,
FKEY
,
HREF
,
NAME
,
SIZE
,
TEK-
FLAGS
,
TYPE
,
VALUE
.
Terminal and console; limited support
Attributes supported:
ACTION
and
METHOD
.
The image is not printed; it is replaced with the text of the
ALT
attribute.
If there is no
ALT
attribute, the image is replaced with the text
[IMG]
.
D-6
Psion Teklogix 9500 Communications Server User Manual
Appendix D: Developing HTML For The CommServer
Text Attribute Tags
D.2.2 Text Attribute Tags
<B>
<U>
Tag
<BLINK>
<STRONG>
<S>,
<STRIKE>
<H1>
,
<H2>
,
<H3>
,
<H4>
,
<H5>
,
<H6>
Meaning
Blink
Bold
“Strong” text Console only
Underline
Strikeout
(Place lines through text)
Heading
Support Tag-Specific Information
Terminal and console
This tag is mapped to the
TESS blinking attribute.
Terminal and console
Terminal and console
Console only
Terminal and console; limited support
This tag is mapped to the
TESS bold attribute.
There is no support in TESS for this tag. Text using it is rendered in a different colour on the Windows console.
This tag is mapped to the
TESS underline attribute.
There is no support in TESS for this tag. Text using it is rendered in a different colour on the Windows console.
These tags are treated as paragraph markers
<P>
because there is no support for fonts in TESS.
Psion Teklogix 9500 Communications Server User Manual
D-7
Appendix D: Developing HTML For The CommServer
Text Formatting Tags
D.2.3 Text Formatting Tags
<PLAINTEXT>
,
<PRE>
<XMP>
<BR>
<P>
<DIV>
<HR>
Tag Meaning Support
Tag-Specific
Information
Place text exactly as presented, including whitespace
Terminal, console
Example
Line break
Terminal, console
Terminal, console
Paragraph break
Division
Horizontal rule
Terminal, console
Due to space restrictions, paragraph spacing is minimal.
Terminal, console; limited support
Terminal and console; limited support
Acts like
<P>
Draws a line of dash characters - across the screen; no justification support
D-8
Psion Teklogix 9500 Communications Server User Manual
Appendix D: Developing HTML For The CommServer
Table, List and Definition Tags
D.2.4 Table, List and Definition Tags
Tag
<OL>
,
<UL>
,
<LI>
,
<DIR>
<TABLE>
,
<TR>
,
<TD>
,
<TH>
Meaning
Ordered list, unordered list, list item, directory
Table, table row, table data, table heading
Support Tag-Specific Information
Limited support
List entries are indented properly. Ordered and unordered lists are rendered with asterisk characters
*
as bullets.
Limited support
Variable-width tables are supported. The column
WIDTH attribute may take a value expressed in pixels or as a percentage of total table width.
<DL>
,
<DT>
,
<DD>
Definition list, definition title, definition data
Limited support
No indentation.
Psion Teklogix 9500 Communications Server User Manual
D-9
Appendix D: Developing HTML For The CommServer
Table, List and Definition Tags
Notes:
1. Not all visual attributes are rendered on character-mode terminals. Some attributes are mapped into terminal’s attributes (for instance, “strong” to
“blink”); other are not used. However all these video attributes are recorded during the page rendering.
2. The named-anchor tag
<A NAME=xxx>
and the corresponding use of the
#
character in the reference tag
<A HREF=#xxx>
are not supported.
3. Text marked with the
<PRE>
tag wraps to the next line if it exceeds the width of the page.
4. It is possible to specify column widths in the
<TH>
and
<TD>
tags with the
WIDTH
attribute:
<TD WIDTH=25%>
or
<TD WIDTH=200>
.
If a percentage value is given, TekHTML assumes that the value is meant as a percentage of the available space for the table on the screen.
If a numeric value is given, TekHTML assumes that the value is a width in pixels. It divides the value by the configured number of pixels per character value, and uses the result as a column width.
Values less than zero are ignored. Totals (of pixels or of percentages) greater than the table width are reduced to make the results fit the space available.
Mixing cells with and without width specifications is possible. The results may look unusual depending on the amount of data in the cells without a width specification.
D-10
Psion Teklogix 9500 Communications Server User Manual
Appendix D: Developing HTML For The CommServer
Function Keys
D.3 Function Keys
D.3.1 Mapping The Function Keys
Psion Teklogix terminals have function keys labeled “F1”, “F2” etc. These keys may be linked (or “mapped”) to the anchor tag
<A>
and the input tag
<INPUT> within HTML pages.
When pages using these mappings are accepted by TekHTML and rendered on a
Psion Teklogix terminal’s screen, the user can press the function key referenced by a link or control. The terminal then performs the appropriate action, requesting a web page or submitting a form. Mapping is done on a per-link basis, and different links can use different mappings. There is no global (application-wide) mapping.
The
FKEY
attribute within a link tag specifies the number of the function key to be used. Currently only the
<A>
and
<INPUT>
tags may contain the
FKEY
attribute.
The
FKEY
attribute may also be expressed as
ACCESSKEY
. These two names may be used interchangeably.
D.3.1.1 Mapping A Function Key To A Hyperlink
Use the following syntax:
<A HREF=<URL> FKEY=n> where
<URL>
is the desired URL and n
is the number (from 1 to 30) of the desired key. For example, the following link invokes a hyperlink to the web address http://www.teklogix.com/
when the terminal user presses the <F8> key:
<A HREF=http://www.teklogix.com FKEY=8>
D.3.1.2 Mapping A Function Key To A Button
Use the following syntax:
<INPUT TYPE=SUBMIT NAME=<BUTTON NAME> VALUE=<BUTTON VALUE>
FKEY=n> where n
is the number (from 1 to 30) of the desired function key. The following input tag submits the form to the HTTP server when the terminal user presses the <F8> key:
<INPUT TYPE=SUBMIT NAME=OK-BUTTON VALUE=OK FKEY=8>
Psion Teklogix 9500 Communications Server User Manual
D-11
Appendix D: Developing HTML For The CommServer
Tags Without Function-Key Support
D.3.2 Tags Without Function-Key Support
The
FKEY
attribute may not be used within certain anchor
<A>
and input
<INPUT>
tags.
The
FKEY
attribute may not be used within the named-anchor tag
<A
NAME=somename>
because the named-anchor tag does not specify a link. It may not be used within certain
<INPUT>
tags as well—some because of their nature, such as
<INPUT TYPE=HIDDEN>
, others because of limitations of the emulator, such as
<INPUT TYPE=CHECKBOX>
.
The emulator prints a message to the debug console or file if such invalid tags are encountered. The incorrect function-key event is ignored.
D.3.3 Predefined Function Keys
Certain function keys are predefined; their action can not be altered. They are given
in Table D.1. Additional values for these keys may be specified when starting
TekHTML using the given configuration commands.
If a programmable function key with the same number is defined in the HTML page
(using the
ACCESSKEY
or
FKEY
attribute), the action of the predefined function key prevails.
Default
Function Key
Action Configuration Command
F1
F2
F3
F30
Go to start page (show the configured home page)
Go back
(show the previous page)
Go forward
(show the next page)
Reset
-fh
n (where n is the number of the desired function key)
-fb
n
-ff
n
-fr
n
Table D.1 Function Key Actions And Configuration Commands
D-12
Psion Teklogix 9500 Communications Server User Manual
Appendix D: Developing HTML For The CommServer
Remapping Function-Key Zero (F0)
D.3.4 Remapping Function-Key Zero (F0)
During operation, the <ENTER> key of the terminal should not be pressed when the cursor is in an entry field. This is because the HTML emulator (browser) does not know which form-submitting tags
<INPUT TYPE=SUBMIT ...>
to use.
The terminal’s <ENTER> key is usually programmed to act as, or be mapped to, function-key zero (F0). While there is no actual F0 key to press on a Psion Teklogix terminal, several events can mimic the press of the key. The data corresponding to an F0 keypress can be artificially created using the <ENTER> key or a scanner.
These mappings are done in the TESS parameter menu in each RF terminal.
If the <ENTER> key is mapped to function-key zero (F0) in the terminal’s TESS-
FIELDS menu (“Enter to F0” = “Y”), then pressing the <ENTER> key on the terminal’s keyboard causes an F0 keypress to occur. The terminal submits the form, sending the form data back to the host. Otherwise, pressing the <ENTER> key simply moves the cursor to the next field on the screen, sending nothing.
By default, the <ENTER> key is mapped to the F0 key.
A similar mapping exists for scanners. In a Psion Teklogix terminal, the TESS-
WAND menu has two settings: “Append Enter” and “Append F0”.
If neither of these is enabled, scanner data is entered into the current field after a scan, and the cursor stays where it happens to be (depending on data size and other settings). If “Append Enter” is selected, the terminal acts as if the <ENTER> key had been pressed, and the cursor moves to the next field. If “Append F0” is selected, the terminal acts as if the F0 key had been pressed after the data was entered, and submits the form data.
The F0 keypress event, like that from any other function key, causes the terminal to send a TESS page to the CommServer, which is translated and sent to the host.
It is possible, however, to remap the F0 key to act as any other function key, using the
FKEYONENTER
attribute. This remapping is on a per-field basis; the key can thus be assigned to any button.
The syntax of the remapping is:
<INPUT TYPE=TEXT FKEYONENTER=n ...> where n
is the number of the function key to be invoked when the <ENTER> key is pressed in this field.
Psion Teklogix 9500 Communications Server User Manual
D-13
Appendix D: Developing HTML For The CommServer
HTML Extensions For TESS
D.4 HTML Extensions For TESS
TekHTML uses TESS to communicate with the terminal, and TESS has many useful features that are not accessible using standard HTML.
These features are accessible through the Psion Teklogix-specific attribute
TEKFLAGS
. This attribute is specified within the standard HTML
<INPUT>
tag, for input fields, or within a Psion Teklogix-specific
<TEKLOGIX>
tag, for output fields.
D.4.1 TEKFLAGS Within The <INPUT> Tag
The syntax of the TEKFLAGS attribute within the
<INPUT>
tag is as follows:
<INPUT TYPE=TEXT TEKFLAGS=xxx ...> where xxx
is a string of one-character flags.
This tag specifies buttons or text fields, which are translated by TekHTML to TESS input fields. Checkboxes and radio-buttons are displayed by TekHTML, but do not work. There is no closing tag for the
<INPUT>
tag.
D.4.2 TEKFLAGS Within The <TEKLOGIX> Tag
The syntax of the TEKFLAGS attribute within the
<TEKLOGIX>
tag is as follows:
<TEKLOGIX TEKFLAGS=xxx> text </TEKLOGIX> where xxx
is a string of one-character flags.
This tag specifies text which will be treated as a TESS “output” field when it is translated into a TESS datastream by TekHTML and passed to the terminal. Only the TEKFLAGS attributes
S
and
I
may be used with the
<TEKLOGIX>
tag.
The
<TEKLOGIX>
tag has a closing tag
</TEKLOGIX>
.
D-14
Psion Teklogix 9500 Communications Server User Manual
Appendix D: Developing HTML For The CommServer
The Flags For The TEKFLAGS Attribute
D.4.3 The Flags For The TEKFLAGS Attribute
The flags are given in Table D.2:
Flag
A
B
C
I
N
R
S
X
Meaning
AUTOTAB: Move the cursor to the next field when this one is filled.
BARCODE: Allow data input from scanner only.
CURSOR: Place the cursor in this field when the page is first displayed.
INVISIBLE: Do not display this field. This attribute may be used to hide buttons and text and leave only the input fields accessible. This flag may be used within both the
<INPUT>
tag and the
<TEK-
LOGIX>
tag.
NUMBER: Accept only numeric data in this field.
RIGHT-JUSTIFY: Place text against right-hand side of field.
SERIAL: Send and receive data through the terminal’s serial I/O port.
When used within the
<INPUT>
tag, this flag makes the specified text input field a TESS serial input field.
When used within the
<TEKLOGIX>
tag, this flag makes the specified text a TESS serial output field. See the TESS manual for details.
TRANSMIT-UPON-ENTRY: Generate an “F0 event” when data is entered in this field.
Table D.2 Flags For The TEKFLAGS Attribute
The INVISIBLE flag
I
can be used to hide buttons from the user if the user is supposed to press function-keys to perform certain actions. The button (defined with the
<INPUT>
tag) is still required to define the action; it also defines the function key to be associated with this action. However, with addition of the
TEKFLAGS=I attribute, the button itself becomes invisible, and therefore inaccessible, in the TESS screen presented to the terminal.
This can also be used to prevent scanner data input into button fields. TESS does not have “protected” fields; the BARCODE flag (the
B
flag) can protect button fields from keyboard data entry, but this doesn’t protect against scanner data entry.
Psion Teklogix 9500 Communications Server User Manual
D-15
Appendix D: Developing HTML For The CommServer
Debugging And Testing With TekHTML
The TRANSMIT-UPON-ENTRY flag
T
can be assigned to the last entry field in a form. Then, with an appropriate
FKEYONENTER
attribute, an F0 keypress event
(either the <ENTER> key or scanner data) can initiate transmission of the form without any additional actions from the user.
D.5 Debugging And Testing With TekHTML
The TekHTML emulator may be started with a number of debug options, which cause it to create messages of various types as it operates. The messages are such things as error messages or status messages describing TekHTML’s operation. This
debug output from the TekHTML emulator may be sent to a file, or to the console screen.
To configure the emulator to send this debug output to a file, start it with the option
-DF
. It then logs debug output messages to the file filedebu.log
. This file is located in the install directory of the TekHTML program. It is overwritten every time the emulator is restarted.
To configure the emulator to send this debug output to the screen, start it with the option
-dC
. All debug messages are then printed to the DOS window. This option is only useful when TekHTML is not running as a Windows NT service.
The emulator has a variety of debugging options available, listed below, which enable the creation of debug messages for various actions. They can be enabled singly, or in combination.
There are two types of debug messages. Emulator debug messages relate to
TekHTML’s parsing and translation of HTML source text. Scheme debug messages relate to the operation of the connection between the emulator and the server which provides it information.
D.5.1 Emulator Debug
The TekHTML option
-d<type>
starts the logging of emulator debug messages.
The
<type>
can be one or more of the following:
A
Show all emulator debug information. This includes all of the
B
,
C
,
D
,
E
,
F
,
L
,
M
,
O
,
P
,
R
,
S
,
T
,
U
, and
X
types.
B
C
Show table debug information. Prints out debug about the parsing and creation of tables.
Show debug information about cookie parsing and storage.
D-16
Psion Teklogix 9500 Communications Server User Manual
Appendix D: Developing HTML For The CommServer
Scheme Debug
D
E
F
L
M
O
P
R
S
T
U
Show debug information generated from the creation of the web page structure. This option generates lots of debug information.
Show HTML parser debug information. This relates to the initial parsing of the web pages.
Show forms debug information.
Show table-layout debug information. This option generates lots of debug information.
Show debug information generated by the main emulator routines
(“general debug”).
Show debug information involving internal HTML objects (one object per tag or block of text).
Show placement debug information (about placement of items on the screen). This option generates extreme amounts of debug information!
Show debug information generated when the emulator receives a response from the web server.
Show scheme-specific debug information generated by the emulator
(not the scheme itself).
Show TESS-specific debug information generated by the TESSlibrary interface.
Show debug information generated when an unsupported tag is seen. Currently, not all unsupported tags generate a message.
X
Show debug information generated by the TSX-library interface.
D.5.2 Scheme Debug
The TekHTML option
-s<type>
starts the logging of scheme debug messages.
The
<type>
can be one or more of the following:
A
Show all scheme debug information for all schemes This includes the
C
,
H
,
M
,
P
,
R
, and
T
types.
Psion Teklogix 9500 Communications Server User Manual
D-17
Appendix D: Developing HTML For The CommServer
Automatic Terminal Response Feature
C
H
Show connection-specific debug information (the connection status and information transfer status).
Show host data debug information (prints host data received by the scheme).
M
P
R
Show timestamping information from the scheme.
Show protocol-specific debug information, such as HTTP encoding and decoding.
Show debug information concerning the response to an HTTP request from the web-server.
T
Show debug information generated by the execution of program threads in the scheme code.
D.5.3 Automatic Terminal Response Feature
In order to automate testing during development, the HTML emulator has an automatic response feature. This can be enabled for terminals in a specified range of terminal numbers.
If the automatic response feature is enabled, and a terminal receives a screen from the host, the emulator will immediately request another page on behalf of that terminal.
The pages are requested from URLs stored in a text file; the name of this file can be specified on the command line using the
-af<filename>
option. This file is stored in the
C:\tekhtml\
directory.
A range of terminals can be specified for autoresponse using the
-at<t1>-<t2> option. Not all terminals need to be configured to respond automatically to requests.
The autoresponse feature is only enabled if a valid file is specified, and if a valid range of terminals is enabled for autoresponse. If the screen capture option
-av<filename>
is also enabled, TekHTML terminates after one pass through the URL list.
D-18
Psion Teklogix 9500 Communications Server User Manual
Appendix D: Developing HTML For The CommServer
Cookies
D.6 Cookies
The following material is provided for Web developers who want to use cookies for state tracking. It is assumed that the developer is already familiar with the basic concepts of cookies.
D.6.1 Overview Of Cookie Transfer
The cookie is always generated at the Web server. The cookie is sent to the browser as part of the server response, along with the requested page. The cookie is sent as a special header:
Set-Cookie: UserName=”John Doe”; Version=1; Path=/cgi-bin;
Max-Age=120
Here is the formal grammar of the
Set-Cookie
header:
Set-Cookie: NAME=VALUE [;Expires=dateValue]
[;Domain=domainName] [;Path=pathName] [;Secure]
The web server can send more than one cookie in the response. The browser accepts all of them.
This Perl script can be a starting point for a Web developer:
#!/usr/local/bin/perl
$maxage = $ENV{QUERY_STRING};
$age = “Max-Age=$maxage”;
$exp = “Expires=$m_exp”;
$path = ‘Path=/cgi-bin’;
$ver = ‘Version=1’; print “Set-Cookie: UserName=\”John Doe\”; $ver; $age; path; $exp\n”; print “Set-Cookie: UserPassword=\”Warp Speed\”; $ver;
$age; $path\n”; print “Content-Type: text/html\n\n\n”; print “<html><body>\n”; print “Cookies have been set to expire in $maxage seconds or on $m_exp.\n”; print “<a href=printenv>Test this cookie now</a></body></html>\n”;
Psion Teklogix 9500 Communications Server User Manual
D-19
Appendix D: Developing HTML For The CommServer
Implementation Of Cookies
This script can be called with query
?cookie-age
in seconds to alter the
Max-
Age=nnn
parameter. The
Expires=
header is more complicated (see page 21)
and its generation is not shown.
When the browser is going to make another request to the same (or a similar) host, it looks at available cookies and sends the appropriate cookies to the Web server.
Criterion of such filtering is fully described in RFC 2109; in brief,
Path
and
Domain
attributes must match to the URL being requested.
The browser combines
NAME=VALUE
pairs from applicable cookies (if any are applicable) and sends them to the Web server in a special
Cookie:
header, as illustrated below for two cookies:
GET /cgi-bin/myRequest HTTP/1.0 ... Cookie:
UserName=”John Doe”; UserPassword=”Warp Speed”
The Web server receives the
Cookie:
header and sets up an environment variable
HTTP_COOKIE:
HTTP_COOKIE = UserName=”John Doe”;
UserPassword=”Warp Speed”
Now the CGI script uses this cookie.
Here is a tiny Perl script which was used to list all environment variables (HTML generation is omitted for brevity): while( ($key,$value) = each %ENV )
{ print “$key=$value\n”; }
D.6.2 Implementation Of Cookies
There are important differences between the HTTP standard as described in RFC
2109, and the de-facto implementation of cookies in both Netscape Navigator and
Microsoft Internet Explorer.
D.6.2.3 Difference In Cookie Expiration Mechanism
RFC 2109 proposes attribute
Max-Age=nnn
to define for long the browser should keep the cookie. This value is given in seconds. The value 0 requests that the browser delete the cookie immediately.
D-20
Psion Teklogix 9500 Communications Server User Manual
Appendix D: Developing HTML For The CommServer
Implementation Of Cookies
Older versions of Netscape and Internet Explorer do not understand the
Max-Age attribute. The Web developer may be forced to use the older
Expires=
attribute, though it is much more difficult to handle.
If the Web application is designed to work only with newer browsers, this may not be a concern, and the
Max-Age=nnn attribute should be used instead of
Expires=
.
The
Expires=
attribute has the following structure:
Wdy, DD-Mon-YY HH:MM:SS GMT where
Wdy
is the day of the week (for example,
Mon
or
Tue
);
DD
is a two-digit representation of the day of the month;
Mon
is a three-letter abbreviation for the month (for example,
Jan
or
Feb
);
YY
is the last two digits of the year;
HH:MM:SS are hours, minutes, and seconds, respectively. This string is not enclosed in double quotes despite the fact that it contains spaces.
A web developer can generate this data string using the following UNIX command: date --utc ‘+%a, %d-%b-%y %T GMT’
TekHTML accepts day names in short and long form (
Wed
or
Wednesday
).
However, all of the
Expires=
attribute is not currently processed, due to the large amount of code needed to properly convert dates. Instead, TekHTML uses a hardcoded expiration period, which is set to 1 year.
If the web developer needs cookies that actually expire, he or she should use the
“new” cookie standard (with the
Max-Age=nnn
attribute).
D.6.2.4 Differences In Returned Data
Netscape and Internet Explorer return only
NAME=VALUE
pairs to the Web server.
RFC 2109 specifies, however, that almost all cookie attributes are returned, prefixed with the
$
character, like this:
POST /acme/pickitem HTTP/1.1 Cookie: $Version=”1”;
Customer=”WILE_E_COYOTE”; $Path=”/acme” [some form data]
This long string is shown as being wrapped, but it is actually all on one line.
If several cookies are returned, it looks like this:
Psion Teklogix 9500 Communications Server User Manual
D-21
Appendix D: Developing HTML For The CommServer
Implementation Of Cookies
POST /acme/process HTTP/1.1 Cookie: $Version=”1”;
Customer=”WILE_E_COYOTE”; $Path=”/acme”;
Part_Number=”Rocket_Launcher_0001”; $Path=”/acme”;
Shipping=”FedEx”; $Path=”/acme” [some form data]
Again, this long string is wrapped.
Older Web servers ignore unknown
NAME s (starting with the
$
character), thus providing backward compatibility. Older browsers do not send this extended cookie at all.
D.6.2.5 Differences In Punctuation
In Netscape’s original proposal, the values in attribute-value pairs did not accept
"
-quoted strings. Servers should be cautious about sending values that require quotes unless they know the receiving user agent understands them (i.e., is using
“new” cookies). A “new” user agent should only use quotes around values in
Cookie
headers when the cookie’s version is compliant with this specification.
In Netscape’s original proposal, no whitespace was permitted around the
=
that separates attribute-value pairs. Such whitespace should therefore be used with caution in new implementations.
For backward compatibility, the separator in the
Cookie
header is the semi-colon
;
everywhere. A server should also accept the comma
,
as the separator between cookie-values for future compatibility.
TekHTML accepts the
;
character as a valid separator in the
Set-Cookie
header, and generates
Cookie
requests using only
;
as a separator. Quoted strings are generated only if the value string from an incoming cookie contains spaces; and this automatically means that such a cookie came from a “new” Web server which, apparently, is willing to accept quoted cookies back.
D-22
Psion Teklogix 9500 Communications Server User Manual
S
OFTWARE
L
ICENSE
A
GREEMENTS
A
PPENDIX
E
E.1 For Psion Teklogix Software . . . . . . . . . . . . . . . . . .E-3
E.2 For IBM Personal Communications Software . . . . . . . . .E-8
Psion Teklogix 9500 Communications Server User Manual
E-1
Appendix E: Software License Agreements
For Psion Teklogix Software
E.1 For Psion Teklogix Software
SOFTWARE LICENSE AGREEMENT
SUMMARY - This Agreement governs the use of Psion Teklogix Software by you.
Your acceptance of this Agreement upon installation or Use of this Software shall signify your agreement to be bound by the terms and conditions specified herein.
The Software is the property of Psion Teklogix Inc. or its licensors and is protected by copyright laws. Psion Teklogix Inc. provides the Software and licenses its use worldwide. You assume responsibility for the selection of the Software to achieve your intended results, and for the Use and results obtained from it.
1. Definitions
"Computer" means a Psion Teklogix RF Equipment or other computer systems owned, leased or otherwise controlled by you.
"Documentation" means any on-line help files or written instructions manuals regarding the use of or related to the Software.
"Proprietary Information" means the Software, Documentation and any complete or partial copies thereof and any other Third Party Software licensed with or as part of the Software, or any information that is identified as or which is reasonably identifiable as confidential and proprietary.
"Psion Teklogix RF Equipment" means a radio frequency equipment on which the
Software has been factory pre-installed and authorized for Use.
"Software" means the Psion Teklogix application software product, licensed for Use in conjunction with the Computer, and any release, update or correction level thereto or any complete or partial copies thereof.
"Third Party Software" means a software program or portion thereof, which is owned, in whole or in part, by an independent third party and licensed to Psion
Teklogix Inc.
"Use" means to install, execute, employ, utilize, store, or display one (1) copy of the
Software on the Computer.
2.
Grant of License
We hereby grant you and you hereby accept a non-exclusive, nontransferable license to Use the Software and Documentation, as authorized under this Agreement. The Software may be used by you only on a single Computer, for
Psion Teklogix 9500 Communications Server User Manual
E-3
Appendix E: Software License Agreements
For Psion Teklogix Software
as long as this Agreement is in effect. As the Software and Documentation are copyrighted and licensed (not sold), we retain title to the Software and any copies made from it. Any copies of the Software you make are subject to the restrictions of this Agreement.
We agree to: a.
provide you with one (1) machine readable copy of the Software. If the
Computer is a Psion Teklogix RF Equipment, the Software has been pre-installed at factory and no media will be provided to you. If the Computer is not a Psion
Teklogix RF Equipment, the Software will be provided to you in a media and it will be your responsibility to install the Software on the Computer.
b.
provide you with one (1) copy of the Documentation; and c.
permit you to make additional copies of the Documentation for your own internal business purposes in connection with the Use of the Software, without charge.
4.
Action You May Take Under this License a.
If you receive a media with the Software, you may make one (1) machine readable copy of the Software solely for backup or archival purposes, provided that you (i) reproduce the copyright notice(s) and any other legend(s) of ownership on each copy or partial copy, and (ii) maintain current records thereof including written records of the location of the Computer and authorized Use of the Software for audit purposes to ensure compliance with this Agreement, given reasonable notice to conduct inspection and audit of such records in a manner not to interfere unreasonably with your normal business activities.
b.
You may permanently transfer the Software license from one Computer to another Computer running on the same operating system, provided that you are not using the Software concurrently on more than one Computer. You are required to obtain a separate license for each Computer on which the Software will be Used.
5.
Actions You May Not Take Under this License
You agree not to do any of the following: a.
copy the Software or the Documentation, in whole or in part, except as otherwise permitted by this Agreement;
E-4
Psion Teklogix 9500 Communications Server User Manual
Appendix E: Software License Agreements
For Psion Teklogix Software
b.
sell, license, sub-license, assign or transfer the Software or Documentation; c.
distribute the Software or the Documentation, in whole or in part, to any third party or provide processing services to third parties on a time-sharing, rental or any other basis; d.
reverse assemble, reverse compile, disassemble, or otherwise translate the
Software, in whole or in part; e.
write or develop any derivative software based on the Software or any
Proprietary Information; or f.
export the Software, or any party thereof, from the country in which its Use is authorized, unless you have our written consent and all required governmental export licenses and approvals.
6.
Disclaimer of Warranty
We do not warrant uninterrupted or error free operation of the Software nor do we warrant that the Software will meet your requirements. We do not assume any responsibility whatsoever for Third Party Software. THE SOFTWARE AND
DOCUMENTATION ARE PROVIDED "AS-IS" WITHOUT ANY WARRANTY
WHATSOEVER. WE DISCLAIM ANY AND ALL REPRESENTATIONS,
WARRANTIES AND CONDITIONS, WHETHER EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR
CONDITIONS OF MERCHANTABLE QUALITY OR FITNESS FOR A
PARTICULAR PURPOSE. YOU ASSUME THE FULL RESPONSIBILITY FOR
THE SELECTION, USE, AND PERFORMANCE OF THE SOFTWARE.
7.
Limitation of Liability
We are liable for no more than the value of the license fee that you paid for the
Software. This limitation is cumulative and our responsibility for multiple claims will not exceed in aggregate this limit.
Under no circumstances are we or our third party suppliers liable for damages of third parties claimed against you, or for harm to your records or data, or special, incidental, indirect, or consequential damages, including but not limited to lost profits, lost business revenue or failure to realize expected savings, even if you informed us of their possibility, or for any delay in delivering or furnishing the
Software. This limitation applies whether you are entitled to claim damages from us
Psion Teklogix 9500 Communications Server User Manual
E-5
Appendix E: Software License Agreements
For Psion Teklogix Software
or our third party suppliers as a matter of contract or tort. Some countries/states do not allow the limitation or exclusion of liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you.
We are not liable to you for any delay or non-performance caused by contingencies beyond our reasonable control, including, without limitation, fire, embargoes, third party labour disputes or strikes, transportation delays, shipping or manufacturing delays by third parties, earthquakes, storms, wars, government or state regulations, or acts of God.
8.
Copyrights
All title and copyrights in and to the Software and Documentation, and any copies thereof, are owned by Psion Teklogix Inc. or its suppliers. The Software and
Documentation is protected by copyright laws and international treaty provisions.
The Software also contains copyright material licensed from our suppliers and all rights to such copyright material rest with such suppliers. You may not remove the copyright notice(s) from any copy of the Software or Documentation.
WE DISCLAIM ALL WARRANTIES AND INDEMNITIES, EXPRESS,
IMPLIED OR STATUTORY, FOR PATENT OR COPYRIGHT INFRINGEMENT.
9.
Proprietary Rights and Confidentiality
This Agreement does not grant you any right to use our name, trade mark, intellectual property or other rights without our consent. We grant you a nontransferable, non-exclusive license to use our intellectual property solely to operate the Software.
You agree not to use or disclose any Proprietary Information provided by us, except for the purposes of this Agreement. You agree not to reproduce any of the copyrighted materials unless expressly permitted by this Agreement.
10.
Ending this Agreement
We may terminate this Agreement and your license to Use the Software without notice if:
(i) you are in material breach of any of the restrictions on your Use of the
Software,
(ii) you fail to make any payment when due to us or one of our affiliates, or
(iii) your rights are assigned by you, by operation of law or otherwise.
E-6
Psion Teklogix 9500 Communications Server User Manual
Appendix E: Software License Agreements
For Psion Teklogix Software
Upon termination, all license fees paid by you are non-refundable. You agree to return or destroy all copies of the Software and Documentation, as well as any other
Proprietary Information in your possession, within fourteen (14) days of the date of termination.
Any rights and obligations under this Agreement that by their nature continue after it ends, will remain in effect until they are completed.
11.
Notices
Notices can be delivered to our address stated below, or delivered by electronic communication including facsimile and internet e-mail. Notice will be effective two
(2) business days after confirmed receipt. Either of us may change our address for notice by giving reasonable notice of this to the other.
Psion Teklogix Inc.
2100 Meadowvale Boulevard
Mississauga, ON L5N 7J9
Canada
Attention: Director, Contracts
12.
General
The laws of the Province of Ontario and the federal laws applicable therein, excluding the conflict of laws provisions, govern this Agreement.
This Agreement may only be modified by written agreement signed by duly authorized representatives expressing their intention that this Agreement be modified.
If any provision of this Agreement is deemed invalid or unenforceable by any country, that particular provision will be deemed modified to the extent necessary to make the provision valid and enforceable, and the remaining provisions will remain in full force and effect.
Failure by us to insist on strict performance or to exercise a right when entitled, does not prevent us from doing so at a later time, either in relation to that default or any subsequent one.
This Agreement will be binding upon and inure to our benefit and to the benefit of our respective successors and assigns.
Psion Teklogix 9500 Communications Server User Manual
E-7
Appendix E: Software License Agreements
For IBM Personal Communications Software
E.2 For IBM Personal Communications Software
END USER LICENSE AGREEMENT
FOR IBM SOFTWARE PROGRAM
The Psion Teklogix products contain certain IBM software program ("Program").
By using the Program, you agree to the terms of this End User License Agreement
("Agreement").
1.
LICENSE:
The Program is owned by IBM or its supplier, and is copyrighted and licensed, not sold. This Agreement grants you a non exclusive license to use one copy of the
Program, only in conjunction with the Psion Teklogix products. Except as expressly provided in this Agreement, you shall have no rights in the Program. b.
c.
2.
a.
RESTRICTIONS:
You may not use, copy, modify or distribute the Program;
You may not reverse assemble, reverse compile or translate the Program;
You may not sublicense, rent or lease the Program; and d.
If you breach any terms of this Agreement, your license may be terminated.
You must then destroy all copies of the Program.
3.
DISCLAIMER:
IBM does not warrant uninterrupted or error-free operation of the Program or that
IBM will correct all Program defects. You are responsible for the results obtained from the use of the Program. IBM AND ITS SUPPLIERS DISCLAIM ALL
WARRANTIES AND CONDITIONS, EXPRESS OR IMPLIED, INCLUDING,
BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
SOME STATES OR JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF
E-8
Psion Teklogix 9500 Communications Server User Manual
Appendix E: Software License Agreements
For IBM Personal Communications Software
EXPRESS OR IMPLIED WARRANTIES, SO THE ABOVE EXCLUSION MAY
NOT APPLY TO YOU. YOU MAY HAVE OTHER RIGHTS WHICH VARY
FROM STATE TO STATE OR JURISDICTION TO JURISDICTION.
4.
LIMITATION OF LIABILITY:
In no event shall IBM or its suppliers be liable for any a) loss of, or damage to, data; b) special, incidental, or indirect damages, or for any economic consequential damages; or c) lost profits, business, revenue, goodwill, or anticipated savings. In any case, IBM's entire liability shall be limited to a) damages for bodily injury
(including death) and damage to real property and tangible personal property and b) the amount of any other actual direct damages up to the charges for the Program.
SOME JURISDICTION DO NOT ALLOW THE EXCLUSION OR LIMITATION
OF LIABILITY, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT
APPLY TO YOU. YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM
STATE TO STATE OR JURISDICTION TO JURISDICTION.
5.
GENERAL:
You agree to comply with all applicable export and import laws. If the Program is acquired in the United States, this Agreement is governed by the laws of the State of
New York. If the Program is acquired in Canada, this Agreement is governed by the laws of the Province of Ontario. If the Program is acquired outside of the United
States or Canada, then the law of the country in which you acquired the Program will apply, subject to certain exceptions as determined by IBM. The United Nations
Convention on Contracts for International Sale of Goods shall not apply.
Psion Teklogix 9500 Communications Server User Manual
E-9
A
PPENDIX
S
UPPORT
S
ERVICES
A
ND
W
ORLDWIDE
O
FFICES
F
Psion Teklogix provides a complete range of product support services to its customers worldwide. These services include technical support and product repairs.
F.1 Technical Support
Technical Support for Mobile Computing Products is provided via e-mail through the Partner Program website. To reach the website, go to www.psionteklogix.com and click on the Partner Program link, which takes you to the Partner Program page.
Then click on the Log-in button or the Register button, depending on whether you have previously registered for Teknet or the Partner Program. (Your UserID and password are the same for TekNet and the Partner Program.) Once you have logged in, search for the “Support Request Form”.
F.2 Product Repairs
International
For product repairs, please contact your local Psion Teklogix office listed on our worldwide website: http://www.psionteklogix.com
Click on the heading labelled “Contacts” to choose a Psion Teklogix technical support representative closest to you.
Canada/U.S.A
Canadian and U.S. customers can receive access to repair services by calling the toll-free number below, or via our secure website (see Technical Support, above).
Note: Customers calling the toll-free number should have their Psion Teklogix customer number or trouble ticket number available.
Voice:
Fax:
1 800 387-8898 (press option “2”)
1 905 812-6304
Web Site: http://service.psionteklogix.com
Psion Teklogix 9500 Communications Server User Guide
F-1
F.3 Worldwide Offices
C
OMPANY
H
EADQUARTERS And Canadian Service Centre
Psion Teklogix Inc.
2100 Meadowvale Blvd.
Mississauga, Ontario
Canada L5N 7J9
Tel: +1 905 813 9900
Fax: +1 905 812 6300
E-mail: [email protected]
N
ORTH
A
MERICAN
H
EADQUARTERS
A
ND
U.S. S
ERVICE
C
ENTRE
Psion Teklogix Corp.
1810 Airport Exchange Boulevard
Suite 500
Erlanger, Kentucky
USA 41018
Tel: +1 859 371 6006
Fax: +1 859 371 6422
E-mail: [email protected]
I
NTERNATIONAL
S
UBSIDIARIES
Psion Teklogix S.A.
La Duranne
135 Rue Rene Descartes
BP 421000
13591 Aix-En-Provence
Cedex 3; France
Tel: +33 4 42 90 88 09
Fax: +33 4 42 90 88 88
E-mail: [email protected]
For a complete listing of international offices, please refer to: www.psionteklogix.com
F
-
2
Psion Teklogix 9500 Communications Server User Guide
I
NDEX
Boldface
indicates a parameter name, and Italics indicates a screen name, as described in the Web Interface Reference Guide.
A
A flag for TEKFLAGS attribute option for emulator debug option for scheme debug
Active Channel textbox
Actively Negotiate with Host checkbox
3274 Telnet Protocol Options C-102
5250 Telnet Protocol Options C-112
AIAG textbox
Alarm checkbox
Allow TCP Sessions checkbox
ANSI Telnet Protocol Options C-96
Analyze button
Analyze RRM Group
ANSI Emulation Options
ANSI Function-Key Mapping
screen
ANSI/Telnet Protocol Options
Arbiter IP Address textbox
Redundancy Parameters C-170, C-171
Arrow Key listbox
Arrow Key Remapping checkbox
Attention Key listbox
3274 SNA Protocol Options C-107
attribute
FKEYONENTER
PASSTHRU
Auto Startup checkbox
Auto-login
Auto-Telnet/Login Enable listbox
ANSI Telnet Protocol Options C-92
Auto-telnet Host listbox
2392 Telnet Protocol Options C-99
3274 SNA Protocol Options C-103
Auto-telnet/login Enable listbox
2392 Telnet Protocol Options C-99
3274 SNA Protocol Options C-103
Failed Prompt textbox
ANSI Telnet Protocol Options C-95,
Password Prompt textbox
ANSI Telnet Protocol Options C-95
Password textbox
ANSI Telnet Protocol Options C-94
User ID Prompt textbox
ANSI Telnet Protocol Options C-94
User ID textbox
ANSI Telnet Protocol Options C-94
Automatic Radio Address textbox
Automatic Terminal Number assignment textboxes
Auto-Startup checkbox
Configure Existing Base Station C-138
Configure New Base Station C-134
Psion Teklogix 9500 Communications Server User Manual
i
Index
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
AUTOTAB flag for TEKFLAGS attribute
Auto-telnet
Auto-Telnet/Login Enable listbox
ANSI Telnet Protocol Options C-92
Host textbox
ANSI Telnet Protocol Options C-93
Terminal Prompt textbox
ANSI Telnet Protocol Options C-93
Auto-telnet Host textbox
2392 Telnet Protocol Options C-99
3274 Telnet Protocol Options C-103
5250 Telnet Protocol Options C-112
Auto-Telnet Without User Action checkbox
2392 Telnet Protocol Options C-99
3274 Telnet Protocol Options C-103
5250 Telnet Protocol Options C-112
Auto-telnet/login enable listbox
2392 Telnet Protocol Options C-99
3274 Telnet Protocol Options C-103
5250 Telnet Protocol Options C-112
B
B flag for TEKFLAGS attribute
<B> tag
Back listbox
HTML Function Key Mapping C-131
Background Colour listbox
Backup IP Address textbox
BARCODE flag for TEKFLAGS attribute
Barcode textbox
Base Station Connectivity: TCP/IP Options
Base Station Menu
screen
Beacon Gateway Interface listbox
802.IQ v2 Features C-166, C-167
Beacon Period textbox
Beacon UDP Port textbox
button (defined)
button: mapping function key to
C
C
option for emulator debug
cables
diagrams
ports pinouts
19680 (modem for PPP console link)
19687 (null-modem for PPP console link)
3002186 (null-modem for PPP console
Callsign Period textbox
Callsign Text textbox
Cancel button
Database Validation Results C-182
Character Width on the Terminal textbox
checkbox (defined)
Clear checkbox
Close Host Sessions on Terminal Reset checkbox
ANSI Telnet Protocol Options C-90
Collision Size textbox
ii
Psion Teklogix 9500 Communications Server User Manual
command region
Command Region textboxes
command-line option
-fb
-ff
-fh
-fr
commands in command region
Commit button
Database Validation Results C-181
Configuration Main Menu
screen
Configure Existing RRM Group
Configure Existing RRM
Configure New Base Station
screen
Configure New Host
Configure New RRM Group
screen
Configure New RRM
connectors
RJ-45
Convert 7 to 8 Bits checkbox
cookies
punctuation in headers returned data for
transfer
Create New User Entry
CURSOR flag for TEKFLAGS attribute
D
D option for emulator debug
Database Validation Results
Index
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
debug options
Delete button
Configure Existing Base Station C-138,
Edit Existing User Entry C-175
General Host Options C-25, C-108, C-
3274 Telnet Terminal Numbering C-
<DIR> tag
Direct TCP Check Duplicate Terminal
Number checkbox
Direct TCP Connections for TekTerm checkbox
Display Entire Database
<DL> tag
<DD> tag
<DT> tag
E
E option for emulator debug
Echo checkbox
Edit Existing User Entry
screen
Emulation and Protocol listbox
Emulation Options
Enable Connect Screen checkbox
5250 SNA Protocol Options C-115
Enable Telnet Authorization checkbox
Miscellaneous System Options C-178
Enabled checkbox
Entry Line textbox
Psion Teklogix 9500 Communications Server User Manual
iii
Index
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
Escape Overhead textbox
Escape Timeout textbox
F
F
-fb command-line option
-ff command-line option
-fh command-line option
Field Overhead textbox
Field Underline Remapping listbox
First Local Terminal Port textbox
ANSI Telnet Protocol Options C-91
2392 Telnet Protocol Options C-98
3274 Telnet Protocol Options C-101
5250 Telnet Protocol Options C-111
First Terminal Listen Port textbox
ANSI Telnet Protocol Options C-91
RF Modem Protocol Options C-121
2392 Telnet Protocol Options C-98
3274 Telnet Protocol Options C-102
5250 Telnet Protocol Options C-111
First Terminal textboxes
Configure Existing Base Station C-137
Configure New Base Station C-134
First Terminal (mode parameter) textbox
5250 SNA Protocol Options C-117
flags
for TEKFLAGS attribute
Foreground Colour listbox
G
General Host Options
screen
General Options
screen
Group textboxes
H
H
Forward listbox
HTML Function Key Mapping C-131
-fr
Free Window Factor textbox
function key back home
mapping to button
mapping to hyperlink predefined
reset
Function Key Font Size listbox
Function Key Mapping
Function Key n listbox
ANSI Function Key Mapping C-125
3274 Function Key Mapping C-128
5250 Function Key Mapping C-130
Function Key Remapping checkbox
Function key zero (F0)
F1 (function key 1)
F2 (function key 2)
F3 (function key 3)
iv
Psion Teklogix 9500 Communications Server User Manual
Index
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
option for scheme debug
<HEAD> tag
Help button
helpdesk
Hidden Match Character textbox
Hidden Match Characters textbox
Home listbox
HTML Function Key Mapping C-131
Host Menu
Host Name textbox
5250 SNA Protocol Options C-114
Host Port textbox
ANSI Telnet Protocol Options C-90
3274 Telnet Protocol Options C-98, C-
5250 Telnet Protocol Options C-111
Host Print checkbox
Host Timeout textbox
HTML
function-key mapping
tags without function-key support
Teklogix extensions to
HTML elements
listbox
text link
textbox
HTML Emulation Options
screen
HTML Emulation Protocol Options
screen
I
HTML emulator
HTMLLIB
HTTP
cookie header cookie implementation
punctuation in cookie headers
<H1>-<H6> tag
Set-Cookie header hyperlink mapping function key to
host application screens via
I
<INPUT> tag
Interface Number listbox
INVISIBLE flag for TEKFLAGS attribute
IP Address textbox
Base Station Connectivity: TCP/IP
Configure Existing RRM C-153, C-154
L
L option for emulator debug
Last Active Session Key textbox
ANSI Telnet Protocol Options C-92
Last Terminal (mode parameter) textbox
5250 SNA Protocol Options C-117
Local checkbox
Local IP Address to Bind textbox
Psion Teklogix 9500 Communications Server User Manual
v
Index
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
ANSI Telnet Protocol Options C-91
2392 Telnet Protocol Options C-98
3274 Telnet Protocol Options C-101
5250 Telnet Protocol Options C-112
Lower Character Set (GL) listbox
LU Name Prefix textbox
3274 Telnet Protocol Options C-102
LU Prefix (mode parameter) textbox
5250 SNA Protocol Options C-117
M
M
option for scheme debug
mapping function key for HTML emulation
function key zero (F0)
Maximum Message Segment Size textbox
Maximum Reconnection Attempts textbox
5250 SNA Protocol Options C-116
Maximum Screen Size (rows x columns) checkbox
Maximum Sessions per Terminal textbox
ANSI Telnet Protocol Options C-90
3274 Telnet Protocol Options C-98, C-
5250 Telnet Protocol Options C-111
Message Mode Limit textbox
Message Size textbox
Configure Existing Base Station C-137
Configure New Base Station C-134
Miscellaneous System Options
Monitor Polls checkbox
9010 Telnet Protocol Options C-119
N
N flag for TEKFLAGS attribute
Name textbox
Configure Existing Base Station C-136
Configure Existing RRM C-153, C-154
Configure New Base Station C-133
Edit Existing User Entry C-175
Name (mode parameter) textbox
5250 SNA Protocol Options C-116
Negotiate Virtual Device Name with Host checkbox
5250 Telnet Protocol Options C-113
Network Name textbox
null-modem cable for PPP link
NUMBER flag for TEKFLAGS attribute
Number of Poll Windows textbox
Number of Retries textbox
O
O option for emulator debug
OK button
3274 Telnet Terminal Numbering C-
Operate in Cellular Mode checkbox
P
P option for emulator debug
<P> tag
Page checkbox
Page Saving consider Double Byte Characters checkbox
Pages textbox
vi
Psion Teklogix 9500 Communications Server User Manual
Index
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
PASSTHRU attributes
Passthru checkbox
Password textbox
Edit Existing User Entry C-175
5250 SNA Protocol Options C-115
Percent Polling Protocol Terminal Timeout textbox
Radio Link Features C-161, C-162
pinouts
RJ-45 connector
<PLAINTEXT> tag
Poll ID textbox
Poll Interval textbox
Poll Timeout textbox
Poll Tries textbox
Polling Protocol Terminal Timeout textbox
Port textbox
Base Station Connectivity: TCP/IP
Configure Existing RRM C-153, C-154
<PRE> tag
Preferred Primary checkbox
Print Form Length textbox
Print Line textbox
Procedures checkbox
Protocol listbox
Configure Existing Base Station C-137
Configure New Base Station C-133
Protocol Options
screen
Proxy Throttling For Non-IP Terminals listbox
R
R
option for emulator debug
Reconnection Timeout textbox
5250 SNA Protocol Options C-116
Redundancy Options
Refrain From Sending Online & Offline Mes-
sages listbox
Remote Print checkbox
Remote Sockets Emulation Options
screen
Remote Sockets Emulation Protocol
Options
screen
Remote Sockets Function-Key Mapping
Remote TxOn textbox
Reset listbox
Psion Teklogix 9500 Communications Server User Manual
vii
Index
HTML Function Key Mapping C-131
Restart Controller Software
screen
Restarting Confirmation
RF Modem Emulation Options
RF Modem Function-Key Mapping
RF Modem/Telnet Protocol Options
RFC 2109
RIGHT-JUSTIFY flag for TEKFLAGS attribute
RJ-45 connector
RLE checkbox
RRM Group Menu
screen
S
S flag for TEKFLAGS attribute
screen
ANSI Function-Key Mapping C-124
ANSI/Telnet Protocol Options C-89
Base Station Connectivity: TCP/IP
Configure Existing RRM Group C-151
Configure New Base Station C-133
Database Valkidation Results C-181
Edit Existing User Entry C-174
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
HTML Emulation Protocol Options C-
Miscellaneous System Options C-177
Remote Sockets Emulation Options C-
Remote Sockets Emulation Protocol
Restart Controller Software C-180
RF Modem Emulation Options C-82
RF Modem Function-Key Mapping C-
RF Modem/Telnet Protocol Options C-
2392 Function-Key Mapping C-132
2392/Telnet Protocol Options C-97
3274 Emulation Options C-33, C-49
3274 Function-Key Mapping C-127
3274 Telnet Terminal Naming C-104
3274/SNA Protocol Options C-106
3274/Telnet Protocol Options C-100
5250 Function-Key Mapping C-129
5250/SNA Protocol Options C-114
5250/Telnet Protocol Options C-110
9010 Function-Key Mapping C-130,
9010/Telnet Protocol Options C-119
screen elements button
radiobutton
textbox
Screen Size textboxes
viii
Psion Teklogix 9500 Communications Server User Manual
screens
Send CR with FKEY checkbox
Send IAC Break as an Attention Key checkbox
3274 Telnet Protocol Options C-103
Send IAC Interrupt Process as a System
Request checkbox
3274 Telnet Protocol Options C-103
SERIAL flag for TEKFLAGS attribute
Serial I/O textbox
Serial Number textbox
Miscellaneous System Options C-177
service information
Session Cycle Key textbox
ANSI Telnet Protocol Options C-92
Show Terminals button
3274 Telnet Terminal Numbering C-
Show
⁄Set button
3274 Telnet Terminal Naming C-105
Size of Poll Windows textbox
SNA Parameters
Start Page textbox
<STRONG> tag
Sync Delay textbox
T
T option for scheme debug
tag
<A>
<B>
<BLINK>
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
<BODY>
heading
<IMG>
<INPUT>
<LI>
<P>
<PLAINTEXT>
<PRE>
<S>
<STRIKE>
<TABLE>
<TR>
unsupported
without support for function-keys
<XMP>
TCP Session Request textbox
ANSI Telnet Protocol Options C-91
<TD> tag
TEKFLAGS attribute flags
<TEKLOGIX> tag
Teklogix extensions to HTML
Terminal Name listbox
3274 Telnet Terminal Naming C-104
Terminal Number listbox
3274 Telnet Terminal Naming C-104
Index
Psion Teklogix 9500 Communications Server User Manual
ix
Index
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
Terminal Offline Timeout textbox
Terminal Protocol listbox
Terminal Range textboxes
Terminal Type listbox
5250 Telnet Protocol Options C-110
Terminal Typelistbox
ANSI Telnet Protocol Options C-90
3274 Telnet Protocol Options C-100
textbox (defined)
Threshold textbox
<TITLE> tag
<TR> tag
Transmit Line textbox
Transmit Lines textbox
TRANSMIT-UPON-ENTRY flag for TEK-
TSF/O checkbox
3274 Emulation Options C-54, C-64
5250 Emulation Options C-71, C-79,
Use International EBCDIC checkbox
Use International EBCDIC checkbox
Use SSCP Sessions checkbox
3274 SNA Protocol Options C-107
User Data Font Size listbox
User Name textbox
5250 SNA Protocol Options C-115
V
Validate button
3274 Telnet Terminal Numbering C-
Virtual Device Name Prefix textbox
5250 Telnet Protocol Options C-113
Visible Match Character textbox
W
Write Error Code listbox
X
X
option for emulator debug
U
U
Undo button
Database Validation Results C-181
Upper Character Set (GR) listbox
2392
commands
2392 Function-Key Mapping
screen
2392/Telnet Protocol Options
x
Psion Teklogix 9500 Communications Server User Manual
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
3274
host application screens via HTTP
3274 Emulation Options
screen
3274 Function-Key Mapping
3274 Telnet Terminal Naming
screen
3274/SNA Protocol Options
screen
3274/Telnet Protocol Options
5250 host application screens via HTTP
5250 Emulation Options
screen
5250 Function-Key Mapping
5250/SNA Protocol Options
screen
5250/Telnet Protocol Options
screen
9010 Emulation Options
screen
9010 Function-Key Mapping
9010/Telnet Protocol Options
screen
Index
Psion Teklogix 9500 Communications Server User Manual
xi
Download