Psion Teklogix 9500 Communications Server User Manual
Reklama
Reklama
9500
Communications Server
User Manual — Part One
February 2, 2005 Part No. 8
100008.B
ISO 9001 Certified
Quality Management System
© Copyright 2005 by Psion Teklogix Inc., Mississauga, Ontario
This document and the information it contains is the property of Psion Teklogix Inc., is issued in strict confidence, and is not to be reproduced or copied, in whole or in part, except for the sole purpose of promoting the sale of Psion Teklogix manufactured goods and services. Furthermore, this document is not to be used as a basis for design, manufacture, or sub-contract, or in any manner detrimental to the interests of
Psion Teklogix Inc.
All trademarks are the property of their respective holders.
Return-To-Factory Warranty
Psion Teklogix warrants a return-to-factory warranty for a period of 90 days from shipment or 120 days from shipment where Psion Teklogix installs the equipment.
The warranty on Psion Teklogix manufactured equipment does not extend to any product that has been tampered with, altered, or repaired by any person other than an employee of an authorized Psion Teklogix service organization. See Psion Teklogix terms and conditions of sale for full details.
Service
When requesting service, please provide information concerning the nature of the failure and the manner in which the equipment was used when the failure occurred.
Type, model, and serial number should also be provided. Before returning any products to the factory, call the Customer Services Group for a Return
Authorization number.
Support Services
Psion Teklogix provides a complete range of product support services to its customers. For contact information and a listing of worldwide offices, please refer to Appendix F: “Support Services And Worldwide Offices”.
Disclaimer
Every effort has been made to make this material complete, accurate, and up-todate. Psion Teklogix Inc. reserves the right to make changes without notice and shall not be responsible for any damages, including but not limited to consequential damages, caused by reliance on the material presented, including but not limited to typographical errors.
T
ABLE OF
C
ONTENTS
Chapter 1: Introduction
1.1 About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 About The Communications Server. . . . . . . . . . . . . . . . . . . . 5
1.4 Emulations And Datastreams . . . . . . . . . . . . . . . . . . . . . . . 6
1.5 Psion Teklogix Network Configurations . . . . . . . . . . . . . . . . . 8
1.5.1 Cellular Switching vs. Timeplexing . . . . . . . . . . . . . . 9
1.5.2 Wireless LAN (WLAN) . . . . . . . . . . . . . . . . . . . . 9
1.5.3 IEEE 802.11 Networking . . . . . . . . . . . . . . . . . . . 10
1.5.4 Inter-Access Point Protocol (IAPP) . . . . . . . . . . . . . . 11
1.5.5 Psion Teklogix’ 802.IQ Protocol . . . . . . . . . . . . . . . 12
Chapter 2: The Hardware
2.1 Introducing The Hardware . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1.1 The Front Of The 9500 CommServer . . . . . . . . . . . . . 15
2.1.2 The Back Of The 9500 CommServer . . . . . . . . . . . . . 17
2.2 Choosing A Location For The CommServer . . . . . . . . . . . . . . . 18
2.3 The Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.3.1 Power Requirements. . . . . . . . . . . . . . . . . . . . . . 18
2.3.2 The Single Power Supply . . . . . . . . . . . . . . . . . . . 21
2.3.3 The Redundant Power Supply (Optional) . . . . . . . . . . . 21
2.3.4 Removing A Swappable Power Supply . . . . . . . . . . . . 22
2.3.5 Installing A Swappable Power Supply . . . . . . . . . . . . 23
2.3.6 Spare Power-Supply Modules . . . . . . . . . . . . . . . . . 23
2.4 The Swappable Hard Drives (Optional) . . . . . . . . . . . . . . . . . 23
2.4.1 The Swappable Hard Drives. . . . . . . . . . . . . . . . . . 24
2.4.2 Removing A Hard Drive . . . . . . . . . . . . . . . . . . . 26
2.4.3 Installing A New Hard Drive . . . . . . . . . . . . . . . . . 27
2.4.4 Spare Drive Carriers . . . . . . . . . . . . . . . . . . . . . . 28
2.5 Connecting To External Devices . . . . . . . . . . . . . . . . . . . . . 28
Psion Teklogix 9500 Communications Server User Manual
i
Contents
2.5.1 The Back Panel Of The Controller. . . . . . . . . . . . . . 29
2.5.2 The Serial Ports . . . . . . . . . . . . . . . . . . . . . . . 30
2.5.3 The Network Cards. . . . . . . . . . . . . . . . . . . . . . 31
2.6 Arrangement And Length Of Cables . . . . . . . . . . . . . . . . . . 31
2.6.1 Distance To System Devices . . . . . . . . . . . . . . . . . 32
2.6.2 Cable Considerations For Each Type Of Connection . . . . 32
2.7 Connecting To Base Stations And Host Computers . . . . . . . . . . . 33
2.7.1 Connecting To Psion Teklogix Base Stations . . . . . . . . 33
2.7.2 Connecting To Host Computers . . . . . . . . . . . . . . . 33
Chapter 3: The 9500’s Software
3.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.1.1 Server Requirements . . . . . . . . . . . . . . . . . . . . . 37
3.2 Setting Up The Software. . . . . . . . . . . . . . . . . . . . . . . . . 38
3.2.1 Configuring The OS Before Installation . . . . . . . . . . . 38
3.2.2 Additional Configuration. . . . . . . . . . . . . . . . . . . 39
3.2.3 Installing The Java Runtime Engine . . . . . . . . . . . . . 39
3.2.4 Registering The 9500 CommServer Software . . . . . . . . 41
3.2.5 Installing The Server Software. . . . . . . . . . . . . . . . 42
3.2.6 Backing Up The System State . . . . . . . . . . . . . . . . 53
3.2.7 Restoring The System State . . . . . . . . . . . . . . . . . 56
3.2.8 Uninstalling The Communications Server Software. . . . . 60
Chapter 4: Connecting To The CommServer
4.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
4.2 The Web Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
4.2.1 Connecting Locally . . . . . . . . . . . . . . . . . . . . . 68
4.2.2 Connecting Remotely . . . . . . . . . . . . . . . . . . . . 68
4.3 The OS Desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
4.3.1 Connecting Locally . . . . . . . . . . . . . . . . . . . . . 69
4.3.2 Connecting Remotely . . . . . . . . . . . . . . . . . . . . 70
4.3.3 Configuring The CommServer’s WTS Server . . . . . . . . 70
4.3.4 The WTS Standalone Client . . . . . . . . . . . . . . . . . 70
4.3.4.1 Installation . . . . . . . . . . . . . . . . . . . . 71
4.3.4.2 Connecting To The Desktop . . . . . . . . . . . 71
4.3.5 The WTS Browser Client . . . . . . . . . . . . . . . . . . 72
4.3.5.1 Connecting To The Desktop . . . . . . . . . . . 72
ii
Psion Teklogix 9500 Communications Server User Manual
Contents
4.4 The Network Console . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
4.4.1 Connecting Locally . . . . . . . . . . . . . . . . . . . . . . 73
4.4.2 Connecting Remotely . . . . . . . . . . . . . . . . . . . . . 73
4.4.3 Network Console Authentication . . . . . . . . . . . . . . . 74
4.4.3.1 Authentication For The PPP Connection . . . . . 75
4.4.3.2 Telnet Authentication . . . . . . . . . . . . . . . 75
4.5 The Windows OS Prompt . . . . . . . . . . . . . . . . . . . . . . . . . 77
4.5.1 Connecting Locally . . . . . . . . . . . . . . . . . . . . . . 77
4.5.2 Connecting Remotely . . . . . . . . . . . . . . . . . . . . . 77
4.6 The Serial Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.6.1 Connecting To The Serial Ports . . . . . . . . . . . . . . . . 78
4.6.2 Setting Up A Modem Connection . . . . . . . . . . . . . . . 80
Chapter 5: Administering The CommServer
5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
5.2 Managing The 9500 CommServer Software . . . . . . . . . . . . . . . 83
5.2.1 The Services Screen . . . . . . . . . . . . . . . . . . . . . . 83
5.2.2 Starting And Stopping The Service . . . . . . . . . . . . . . 85
5.3 SNMP Administration. . . . . . . . . . . . . . . . . . . . . . . . . . . 87
5.3.1 Setting SNMP Parameters . . . . . . . . . . . . . . . . . . . 87
5.4 SNA Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
5.5 Chassis Monitor Administration . . . . . . . . . . . . . . . . . . . . . 97
5.5.1 Starting the Chassis-Monitor Software . . . . . . . . . . . . 97
5.5.2 The Temperature Configuration Screen . . . . . . . . . . . . 99
5.5.3 The Power-supply Configuration Screen . . . . . . . . . . 100
5.5.4 The Alerts Configuration Screen . . . . . . . . . . . . . . 101
5.5.5 The Operating-Time Configuration Screen . . . . . . . . . 103
5.6 Disk Array Administration . . . . . . . . . . . . . . . . . . . . . . . 103
5.6.1 Starting The Disk-Monitoring Software. . . . . . . . . . . 103
5.6.2 Overall Options . . . . . . . . . . . . . . . . . . . . . . . 106
5.6.3 Array Monitoring . . . . . . . . . . . . . . . . . . . . . . 110
5.6.4 User Options. . . . . . . . . . . . . . . . . . . . . . . . . 111
5.7 Viewing Application Log Files . . . . . . . . . . . . . . . . . . . . . 112
5.8 Network Console Commands . . . . . . . . . . . . . . . . . . . . . . 114
5.8.1 Selected Configuration Commands . . . . . . . . . . . . . 114
5.8.2 Selected Network Console Commands . . . . . . . . . . . 115
5.9 Security And Identification . . . . . . . . . . . . . . . . . . . . . . . 116
Psion Teklogix 9500 Communications Server User Manual
iii
Contents
Chapter 6: Set-Up For ANSI Emulation
6.1 Types Of Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 119
6.2 ANSI (Over Ethernet) . . . . . . . . . . . . . . . . . . . . . . . . . . 120
6.2.1 Physical Connection . . . . . . . . . . . . . . . . . . . . . 120
6.2.2 Host Configuration: ANSI-TCP/IP . . . . . . . . . . . . . 120
6.2.3 CommServer Configuration: ANSI-TCP/IP . . . . . . . . . 120
6.2.3.1 Setting Up The Network Adaptor . . . . . . . . 120
6.2.3.2 Specifying The CommServer’s TCP/IP Settings 121
6.2.3.3 Setting Up The CommServer’s Host Table . . . 122
6.2.3.4 Setting Up The CommServer’s Routing Table . 123
6.2.3.5 Setting Up The Host Connection . . . . . . . . 124
Chapter 7: Set-Up For 2392 Emulation
7.1 Types of Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 137
7.2 2392-TCP/IP (Over Ethernet) . . . . . . . . . . . . . . . . . . . . . . 138
7.2.1 Physical Connection . . . . . . . . . . . . . . . . . . . . . 138
7.2.2 DTC Configuration: 2392-TCP/IP . . . . . . . . . . . . . . 138
7.2.3 CommServer Configuration: 2392-TCP/IP . . . . . . . . . 140
7.2.4 Setting Up The Network Connection . . . . . . . . . . . . 141
7.2.4.1 Setting Up The Network Adaptor . . . . . . . . 141
7.2.4.2 Specifying The CommServer’s TCP/IP Settings 141
7.2.4.3 Setting Up The CommServer’s Host Table . . . 142
7.2.4.4 Setting Up The CommServer’s Routing Table . 143
7.2.4.5 Setting Up The Host Connection . . . . . . . . 144
Chapter 8: Set-Up For 3274 Emulation
8.1 Types Of Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 153
8.2 3274/SNA Over Ethernet . . . . . . . . . . . . . . . . . . . . . . . . 154
8.2.1 Physical Connection . . . . . . . . . . . . . . . . . . . . . 154
8.2.2 Host Configuration: 3274 SNA . . . . . . . . . . . . . . . 155
8.2.3 CommServer Configuration: 3274 SNA . . . . . . . . . . . 157
8.2.3.1 Setting Up The Network Adaptor . . . . . . . . 158
8.2.3.2 Specifying The Controller’s SNA Parameters . . 158
8.2.3.3 Setting The CommServer’s SNA Options . (LUA to
LU2) . . . . . . . . . . . . . . . . . . . . . . . . . . 159
8.2.3.4 Setting Up The Host Connection . . . . . . . . 166
iv
Psion Teklogix 9500 Communications Server User Manual
Contents
8.3 3274 TCP/IP Over Ethernet . . . . . . . . . . . . . . . . . . . . . . . 173
8.3.1 Physical Connection . . . . . . . . . . . . . . . . . . . . . 173
8.3.2 Host Configuration: 3274 TCP/IP. . . . . . . . . . . . . . 173
8.3.3 CommServer Configuration: 3274 TCP/IP . . . . . . . . . 175
8.3.3.1 Specifying The Controller’s TCP/IP Settings . . 176
8.3.3.2 Setting Up The Controller’s Host Table. . . . . 177
8.3.3.3 Setting Up The Host Connection . . . . . . . . 177
Chapter 9: Set-Up For 5250 Emulation
9.1 Types Of Connections. . . . . . . . . . . . . . . . . . . . . . . . . . 189
9.2 5250 SNA (LU6.2) Over Ethernet . . . . . . . . . . . . . . . . . . . 190
9.2.1 Physical Connection . . . . . . . . . . . . . . . . . . . . . 190
9.2.2 Host Configuration: 5250 SNA . . . . . . . . . . . . . . . 191
9.2.3 CommServer Configuration: 5250 SNA . . . . . . . . . . 196
9.2.3.1 Setting Up The Network Adaptor . . . . . . . . 197
9.2.3.2 Specifying The Controller’s SNA Parameters . 197
9.2.3.3 Setting The Controller’s SNA Options (APPC to
LU6.2) . . . . . . . . . . . . . . . . . . . . . . . . . 198
9.2.3.4 Setting Up The Host Connection . . . . . . . . 209
9.3 5250 TCP/IP Over Ethernet . . . . . . . . . . . . . . . . . . . . . . . 218
9.3.1 Physical Connection . . . . . . . . . . . . . . . . . . . . . 218
9.3.2 Host Configuration: 5250 TCP/IP. . . . . . . . . . . . . . 218
9.3.3 CommServer Configuration: 5250 TCP/IP . . . . . . . . . 221
9.3.3.1 Setting Up The Network Adaptor . . . . . . . . 221
9.3.3.2 Specifying The Controller’s TCP/IP Settings . . 222
9.3.3.3 Setting Up The Controller’s Host Table. . . . . 223
9.3.3.4 Setting Up The Host Connection . . . . . . . . 224
Chapter 10: Set-up For HTML Emulation
10.1 Types Of Connections. . . . . . . . . . . . . . . . . . . . . . . . . . 235
10.2 CommServer Configuration: HTML/TESS. . . . . . . . . . . . . . . 236
10.2.1 Setting Up The Network Connection . . . . . . . . . . . . 236
10.2.1.1 Setting Up The Network Adaptor . . . . . . . . 236
10.2.1.2 Specifying The Controller’s TCP/IP Settings . . 237
10.2.1.3 Setting Up The Controller’s Host Table. . . . . 238
10.2.1.4 Setting Up The Controller’s Routing Table . . . 238
10.2.2 Setting Up The Host Connection . . . . . . . . . . . . . . 240
Psion Teklogix 9500 Communications Server User Manual
v
Contents
10.3 Operating A Terminal Using HTML Emulation. . . . . . . . . . . . . 245
10.4 How The HTML Emulator Handles Errors . . . . . . . . . . . . . . . 246
Chapter 11: Set-up For Remote Sockets
11.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
11.2 CommServer Configuration: Remote Sockets. . . . . . . . . . . . . . 252
11.2.1 Configuring Radio Link Features . . . . . . . . . . . . . . 253
11.2.2 Configuring The Network Interface . . . . . . . . . . . . . 255
11.2.2.1 Setting Up The Network Adaptor . . . . . . . . 255
11.2.2.2 Specifying The Controller’s TCP/IP Settings . . 256
11.2.2.3 Setting Up The Controller’s Host Table . . . . . 257
11.2.3 Configuring The Remote Sockets Host . . . . . . . . . . . 257
11.3 Terminal Configuration For Remote Sockets . . . . . . . . . . . . . . 261
Chapter 12: Connecting To Bases
12.1 The CommServer And Its Bases. . . . . . . . . . . . . . . . . . . . . 265
12.1.1 Types Of Bases . . . . . . . . . . . . . . . . . . . . . . . . 265
12.1.1.1 The Base Station . . . . . . . . . . . . . . . . . 265
12.1.1.2 The Remote Radio Module . . . . . . . . . . . 265
12.1.1.3 The Access Point. . . . . . . . . . . . . . . . . 266
12.1.1.4 Differences . . . . . . . . . . . . . . . . . . . . 266
12.2 Connecting To Bases. . . . . . . . . . . . . . . . . . . . . . . . . . . 268
12.2.1 Connecting To A Networked Base Station. . . . . . . . . . 268
12.2.1.1 Configuring The Network Card . . . . . . . . . 270
12.2.1.2 Specifying The Controller’s TCP/IP Settings . . 270
12.2.1.3 Configuring The Base Station Connection. . . . 271
12.2.1.4 Adding Base Stations To The Host Table . . . . 274
12.2.1.5 Adding Base Stations To The Routing Table . . 274
12.2.2 Connecting To A Networked RRM . . . . . . . . . . . . . 276
12.2.2.1 Configuring The Network Card . . . . . . . . . 277
12.2.2.2 Specifying The Controller’s TCP/IP Settings . . 277
12.2.2.3 Configuring An RRM Group . . . . . . . . . . 278
12.2.2.4 Adding The RRMs To The RRM Group . . . . 282
12.2.2.5 Adding The RRMs To The Host Table . . . . . 284
12.2.2.6 Adding The RRMs To The Routing Table. . . . 284
12.2.3 Using An Access Point. . . . . . . . . . . . . . . . . . . . 285
12.2.3.1 Configuring The CommServer For TCP Direct . 287
vi
Psion Teklogix 9500 Communications Server User Manual
Contents
Chapter 13: Specifications
13.1 Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
13.2 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . 291
13.3 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 291
13.4 Processor And Memory . . . . . . . . . . . . . . . . . . . . . . . . . 291
13.5 LAN Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
13.6 Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
Psion Teklogix 9500 Communications Server User Manual
vii
A
PPROVALS
A
ND
S
AFETY
I
NFORMATION
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiated radio frequency energy, and if not installed and used in accordance with the manufacturer instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation distance between the equipment and the receiver.
• If you are using the equipment with a mains adapter, plug it into an outlet which is on a different circuit from that to which the receiver is connected.
• Consult an experienced radio/TV technician for help.
Changes or modifications not expressly approved by Psion Teklogix Inc. can void the user's authority to operate the equipment.
An unshielded plug or cable may cause radiation interference. All peripheral devices must be used with properly shielded interface cables and external filters as required. The shield must be connected directly to the chassis of the peripheral device.
Emissions Information For Canada
This Class B digital apparatus meets all requirements of the Canadian Interference-
Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Psion Teklogix 9500 Communications Server User Manual
ix
Safety Summary
.
R
EGULATORY
A
PPROVALS
UL/ CSA certificate, CB certificate
FCC DECLARATION OF CONFORMITY (D
O
C)
Applicant's Name & Address: Avnet Applied Computing Canada
Northeast US & Canada sales office
10 Centennial Drive, Ste 207
Peabody, MA 01960, USA
US Representative's Name & Address:
Equipment Type/Environment:
Trade Name / Model No.:
Psion Teklogix Corp.
North America Headquarters
1810 Airport Exchange Blvd. Suite 500
Erlanger, KY 41018 USA
Computing Devices for Home and Office Use
9500 Communications Server
Year of Manufacture: 2003
Standard(s) to which Conformity is Declared:
The 9500 product, supplied by Psion Teklogix, has been tested and found to comply with FCC
PART 15, SUBPART B - UNINTENTIONAL RADIATORS, CLASS B COMPUTING
DEVICES FOR HOME & OFFICE USE.
x
Psion Teklogix 9500 Communications Server User Manual
Safety Summary
CE MARKING
When used in a residential, commercial or light industrial environment, this product and its approved UK and European peripherals fulfill all requirements for
CE marking.
Product:
Declaration of Conformity
9500 Communications Server
Application of Council Directives:
EMC Directive: 89/336
EEC Low Voltage Directive: 73/23/EEC
Conformity Declared to Standards:
EN 55022: 1998, Class B;
EN 61000-3-2;
EN 61000-3-3
EN 55024: 1998
EN 61000-4-2; ±4kV CD; ±8kV AD
EN 61000-4-3; 3V/m, 80-1000 MHz
EN 61000-4-4; ±0.5kV Signal lines; ±1kV Power lines
EN 61000-4-5; ±2kV Com/±1kV Diff on AC; ±1kV on I/O
EN 61000-4-6; 3VRMS, 150kHz-80MHz
EN 61000-4-11; AC Mains Ports
EN 60950: 1992 + A1 + A2 + A3 + A4
Year of Manufacture:
Type of Equipment:
2003
Information Technology Equipment
Equipment Class:
Manufacturer:
Legal Representative in Europe:
Residential, Commercial and Light Industrial
Avnet Applied Computing Canada
PSION TEKLOGIX S.A. France
Psion Teklogix 9500 Communications Server User Manual
xi
Safety Summary
I
MPORTANT
S
AFETY
I
NSTRUCTIONS
This safety information is for the protection of both operating and service personnel.
D
O
N
OT
O
PERATE
I
N
A
N
E
XPLOSIVE
A
TMOSPHERE
Operating Psion Teklogix equipment where explosive gas is present may result in an explosion.
D
O
N
OT
R
EMOVE
C
OVERS
O
R
O
PEN
E
NCLOSURES
To avoid injury, the equipment covers and enclosures should only be removed by qualified service personnel. Do not operate the equipment without the covers and enclosures properly installed.
A
LWAYS
G
ROUND
E
QUIPMENT
To avoid electric shock, the power cord's protective grounding conductor must always be connected to ground.
D
ISCONNECT
P
OWER
B
EFORE
S
ERVICING
When servicing the 9500, make sure all power supplies are discounted from
AC power!
This warning does not apply to replacing the swappable hard drive module or the swappable power-supply module.
U
SE
S
URGE
P
ROTECTORS
W
HEN
C
ONNECTING
T
O
O
UTDOOR
E
QUIPMENT
To avoid possible surge effects when the CommServer or its Ethernet cable are connected to outdoor equipment or used in an outdoor environment, we recommend that you install a surge protector on the Ethernet cable.
xii
Psion Teklogix 9500 Communications Server User Manual
I
NTRODUCTION
1.1 About This Manual . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Text Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 About The Communications Server . . . . . . . . . . . . . . . . 5
1.4 Emulations And Datastreams . . . . . . . . . . . . . . . . . . . 6
1.5 Psion Teklogix Network Configurations. . . . . . . . . . . . . . 8
1.5.1 Cellular Switching vs. Timeplexing . . . . . . . . . . 9
1.5.2 Wireless LAN (WLAN) . . . . . . . . . . . . . . . . 9
1.5.3 IEEE 802.11 Networking . . . . . . . . . . . . . . . 10
1.5.4 Inter-Access Point Protocol (IAPP). . . . . . . . . . 11
1.5.5 Psion Teklogix’ 802.IQ Protocol . . . . . . . . . . . 12
1
Psion Teklogix 9500 Communications Server User Manual
1
Chapter 1: Introduction
About This Manual
1.1 About This Manual
This manual contains information on the installation, basic operation, and configuration of the Psion Teklogix Communications Server. The manual contains two parts, bound as separate books.
Part One contains setup and configuration information:
Introduces the Psion Teklogix 9500 Communications Server.
Describes the physical installation of the CommServer.
Chapter 3: The 9500’s Software
Describes the installation of the software-only version of the CommServer. This version is intended for installation on a customer-supplied server.
Chapter 4: Connecting To The CommServer
Describes methods of connecting to the CommServer.
Chapter 5: Administering The CommServer
Describes ways to connect to and configure the CommServer.
Chapter 6: Set-Up For ANSI Emulation
Describes host and CommServer configuration for connections under ANSI emulation.
Chapter 7: Set-Up For 2392 Emulation
Describes host and CommServer configuration for connections using 2392 emulation.
Chapter 8: Set-Up For 3274 Emulation
Describes host and CommServer configuration for connections using 3274 emulation.
Chapter 9: Set-Up For 5250 Emulation
Describes host and CommServer configuration for connections under 5250 emulation.
Chapter 10: Set-up For HTML Emulation
Describes host and CommServer configuration for connections under HTML emulation.
Psion Teklogix 9500 Communications Server User Manual
3
Chapter 1: Introduction
About This Manual
Chapter 11: Set-up For Remote Sockets
Describes host and CommServer configuration for connections using Remote
Sockets.
Chapter 12: Connecting To Bases
Discusses connection of the CommServer to base stations, remote radio modules (RRMs), and access points.
Contains the technical specifications for the CommServer.
Part Two, the Appendices, contains reference material:
Appendix A: Ports, Pinouts And Cable Diagrams
Describes the ports of the CommServer Communications Server and the cables that connect to them.
Appendix B: Setting Terminal Numbers On The CommServer
Explains the effects of various settings on terminal numbers for host emulations.
Appendix C: The 9500 CommServer’s Web Interface
Describes all the parameters and screens of the CommServer’s Web-based configuration interface.
Appendix D: Developing HTML For The CommServer
Discusses the CommServer’s HTML emulation, by which it can convert HTML pages to the TESS screens used by Psion Teklogix terminals.
Appendix E: Software License Agreements
License agreements for the CommServer’s Psion Teklogix and IBM software.
Appendix F: Support Services And Worldwide Offices
Gives information on Psion Teklogix’ technical support, and contact information for Psion Teklogix’ offices worldwide.
4
Psion Teklogix 9500 Communications Server User Manual
Chapter 1: Introduction
Text Conventions
1.2 Text Conventions
Note: Notes highlight additional helpful information.
Important: These statements provide particularly important instructions or additional information that is critical to the operation of the computer and other equipment.
Warning: These statements provide important information that may prevent injury, damage to the equipment, or loss of data.
1.3 About The Communications Server
Figure 1.1 The Front Of The Communications Server
The Psion Teklogix Communications Server is available:
• as software running on Psion-Teklogix-provided hardware.
• as software only, to run on a server of the customer’s choosing. The software version is available as Model S900 and Model S900L. Model S900L handles fewer terminals and is intended for smaller installations.
Both the software-only version and the hardware version are referred to as the
CommServer in this document. The hardware version of the Communications
Server is also referred to as a Model 9500 network controller. It is available with a number of options, including redundant power supples and hard drives.
Psion Teklogix 9500 Communications Server User Manual
5
Chapter 1: Introduction
Emulations And Datastreams
The CommServer can control a Psion Teklogix network consisting of:
• one or more bases (9140s/9150s) in Base Station mode.
• one or more bases (9150s) in Remote Radio Module (RRM) mode.
• one or more RF terminals.
The CommServer also works with third-party access points and network devices.
1.4 Emulations And Datastreams
A network controller, such as the Psion Teklogix Communications Server, in a Psion
Teklogix RF system performs a number of important tasks. One of these tasks is
emulation conversion: the translation of data between the emulation of the host computer and the emulation used by Psion Teklogix terminals.
The data that is sent from a host computer to a terminal to provide its display, and the data which is returned to the host as a result of operations at the terminal, is called a datastream. Host computers can provide datastreams of various types to their terminals.
Traditional Psion Teklogix terminals can directly accept only two types of datastream: TESS and ANSI. TESS (TEklogix Screen Subsystem) is the native emulation used by the original Psion Teklogix terminals. With TESS, all the features of Psion Teklogix terminals such as page-saving, Passthru printing, and TSF/O can be used. ANSI emulation is a standard type of datastream used by wired VT-type terminals; these terminals are specified by the American National Standards
Institute. Psion Teklogix terminals can also be configured to accept ANSI datastreams.
Some Psion Teklogix devices can accept HTML datastreams. HTML (HyperText
Markup Language) is the name of the datastream through which web pages are displayed in a web browser.
Other types of supported datastream provided by the host must be converted into
TESS or HTML datastreams, before Psion Teklogix terminals can work with them.
This is the job of the emulation software in the CommServer.
6
Psion Teklogix 9500 Communications Server User Manual
Chapter 1: Introduction
Emulations And Datastreams
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
ANSI
TESS
PTX
Handler Software
PTX
Emulation
Software
9500 CommServer
Base
ANSI
Terminal
Software
TESS
Web
Browser
HTTP
Terminal
HTTP Server
Host Computer
Figure 1.2 Possible Datastreams In The Psion Teklogix RF System
The emulation software in the Psion Teklogix Communications Server can accept
IBM 5250, IBM 3274, HP 2392, and HTML datastreams from host computers, and can convert them to and from TESS. The CommServer caches and compresses information when creating TESS datastreams, to make the RF link work more efficiently. This is most useful when sending through low-bandwidth connections.
The emulation software can also convert IBM 5250 and IBM 3274 datastreams to
HTML datastreams, so that they may be viewed through a web browser in the terminal. The CommServer does not cache or compress HTML datastreams.
ANSI datastreams from host computers can simply be passed on to the terminal.
The CommServer can, however, cache and compress ANSI datastreams to conserve bandwidth on the RF network.
Some hosts may have Psion Teklogix ‘handler’ or ‘SDK’ software. This software runs inside the host and communicates directly with the host’s applications.
Handlers and SDKs provide TESS datastreams which are compatible with Psion
Teklogix terminals.
Psion Teklogix 9500 Communications Server User Manual
7
Chapter 1: Introduction
Psion Teklogix Network Configurations
1.5 Psion Teklogix Network Configurations
With the appropriate configuration, the Psion Teklogix Communications Server can emulate an IBM 3274/3174, or an IBM 5250 controller. Psion Teklogix RF terminals therefore appear to be standard IBM terminals to the host computer. The
CommServer can also act as an ANSI terminal server. TCP/IP is supported over the
Ethernet interfaces.
Using host-resident software and a proprietary asynchronous protocol, the
CommServer can communicate with UNIX hosts, PCs, and VMS hosts. The
CommServer can interface with several host computers over an Ethernet network.
A configuration with Ethernet is shown in Figure 1.3 below.
Please consult the relevant section of this manual for information about cabling, host setup, and CommServer configuration for your system.
9150
Base
Stations
9150
Base
Stations
9500
Ethernet - TCP/IP
Serial connection for RAS
Console
DEC Host HP Host IBM RS/6000 Host
9140
9150
Teklogix
Wireless Gateways
Teklogix 9400
Network Controller
Teklogix 9300
Network Controller
Figure 1.3 A CommServer Network With Ethernet
8
Psion Teklogix 9500 Communications Server User Manual
Chapter 1: Introduction
Cellular Switching vs. Timeplexing
1.5.1 Cellular Switching vs. Timeplexing
In Psion Teklogix proprietary systems, there are two methods of operating on a narrow-band radio link. The first method is called cellular switching. It is similar in concept to cellular telephone systems. Here, each base uses a different radio channel. The terminals monitor the radio link and automatically switch to the channel with best radio reception. This cellular switching capability is transparent to both the host and the terminal.
The second method is called timeplexing. Here, a group of bases at a site use the same radio channel. The CommServer controls the polling sequence so that the bases do not transmit simultaneously. This timeplexing capability is also transparent to both the host and the terminal.
Cellular switching and timeplexing can be combined within one Psion Teklogix system: a site may operate on two or more channels, with several timeplexed bases using each channel, and cellular switching between the channels.
In all of these cases, the terminal may move freely throughout the site without loss of communication. The Psion Teklogix system seamlessly handles channelswitching and handovers between bases.
1.5.2 Wireless LAN (WLAN)
The Psion Teklogix Wireless LAN (WLAN) system allows sites using Psion
Teklogix proprietary protocols to expand radio coverage to physically-difficult-toreach areas by adding wireless base stations. Wireless base stations communicate with terminals and also with wired and wireless base stations over the radio link.
A WLAN system consists of a minimum of one wired base station and one or more wireless base stations. It can operate on either one channel or multiple channels.
When a wireless base station is added to the WLAN, it receives routing information from other base stations, determines the best communication route, and begins passing messages from terminals to wired base stations. If a better route is available, the wireless base station can change communication paths.
Terminals moving through the WLAN communicate with the base stations that provide the best communication path to a wired base station. Communication paths are rated by channel quality and number of ‘hops’ (communications between base
Psion Teklogix 9500 Communications Server User Manual
9
Chapter 1: Introduction
IEEE 802.11 Networking
stations) to a wired base station. If multiple channels are used, the terminals continually search for the clearest channel and will switch to it if the quality of the current channel becomes unacceptable.
1.5.3 IEEE 802.11 Networking
Psion Teklogix bases can also serve as ‘access points’ for systems using radios complying with the IEEE 802.11 standard. Access points bridge data between the wired and wireless networks.
The IEEE 802.11 protocol is a standard for Wireless Local Area Networks
(WLANs). With this standard, any device with an IEEE 802.11 radio can communicate with any other similarly-equipped device. However, IEEE 802.11 does not provide a standard for a total WLAN system. IEEE 802.11 solely standardizes two communications layers: Physical (PHY) and Medium Access
Control (MAC).
Three different physical layers (combinations of low-level protocol and media) are covered: 2.4 GHz Direct Sequence Spread Spectrum radio, 2.4 GHz Frequency
Hopping Spread Spectrum radio, and infrared. Each station in a WLAN system has its own unique MAC address.
Important: Equipment using one physical layer will not interoperate with equipment using a different physical layer.
IEEE 802.11 uses radios of relatively low power. The range of the radio is limited depending on the conditions. Therefore, most wireless networks need more than one coverage area, with terminals moving between the areas. To integrate those areas with a wired network, systems using IEEE 802.11 protocol for their wireless networks require an IEEE 802.11-equipped bridge device (or ‘access point’), such as the Psion Teklogix 9150 Wireless Gateway.
Using bridging software, the access point enables communication between wireless
IEEE 802.11-equipped stations and LAN stations connected to the wired Ethernet network. The access point itself is resident on the LAN and functions as a MAC bridge, providing transparent integration between the stations on the wireless and wired networks.
10
Psion Teklogix 9500 Communications Server User Manual
Chapter 1: Introduction
Inter-Access Point Protocol (IAPP)
Each wireless terminal is associated with one access point. A frame from an RF terminal is sent to the access point that the terminal is associated with. The terminal puts a destination MAC address in the frame, which specifies a hardware address on the wired LAN side.
Because the receiving access point is connected to an Ethernet network, it encapsulates the data in an Ethernet frame, including the destination MAC address specified by the terminal. The access point then sends the frame onto the physical network; the frame is picked up by whichever device is at the destination hardware address.
When sending frames from the LAN side, the sending device puts the MAC address of the terminal in the frame header. The access point, which has that terminal associated with it, takes the frame and passes it over the RF network to the terminal.
1.5.4 Inter-Access Point Protocol (IAPP)
A Basic Service Set (BSS) is a set of mobile stations (terminals) controlled by a single coordination function, such as an access point within the terminals’ radio coverage area.
The Inter-Access Point Protocol, IAPP, facilitates roaming of mobile stations across different Basic Service Sets and specifies how access points communicate with each other. It is an extension to the IEEE 802.11b protocol.
In a multiple-access-point system, IAPP informs the other access points when a new access point becomes active, and enables the access points to be aware of each other.
With IAPP, an IEEE 802.11b system can operate on one or more channels, with terminals moving between the access points. Although each terminal is associated with one access point, it can re-associate with another access point to maintain uninterrupted communications.
The newly-associated access point will receive the terminal’s data frames and pass them onto the LAN. Returning frames are no longer accepted by the original access point, which has disassociated from that terminal. The returning frames are now accepted by the newly-associated access point and passed over the radio network to the terminal.
Psion Teklogix 9500 Communications Server User Manual
11
Chapter 1: Introduction
Psion Teklogix’ 802.IQ Protocol
1.5.5 Psion Teklogix’ 802.IQ Protocol
802.IQ is a Psion Teklogix proprietary protocol optimized to operate in a wireless
LAN. 802.IQ protocol is available in two versions: 802.IQv1 and 802.IQv2. Psion
Teklogix 9150 base stations are necessary to support both versions of the protocol at the same time (terminals must use only one).
802.IQv1 is an efficient proprietary non-TCP/IP over-the-air protocol that eliminates the need for a TCP/IP stack on a terminal. Psion Teklogix’ base stations convert it to the protocols of the wired network.
802.IQv2 protocol is an enhanced version of the 802.IQv1 protocol that transports packets over the UDP layer. It provides all of 802.IQv1’s capabilities. It also allows the terminal to use a TCP/IP stack, and communicate with the CommServer through any third-party 802.11 access-point.
12
Psion Teklogix 9500 Communications Server User Manual
T
HE
H
ARDWARE
2
2.1 Introducing The Hardware . . . . . . . . . . . . . . . . . . . . 15
2.1.1 The Front Of The 9500 CommServer . . . . . . . . 15
2.1.2 The Back Of The 9500 CommServer. . . . . . . . . 17
2.2 Choosing A Location For The CommServer . . . . . . . . . . 18
2.3 The Power Supply . . . . . . . . . . . . . . . . . . . . . . . . 18
2.3.1 Power Requirements . . . . . . . . . . . . . . . . . 18
2.3.2 The Single Power Supply . . . . . . . . . . . . . . . 21
2.3.3 The Redundant Power Supply (Optional) . . . . . . 21
2.3.4 Removing A Swappable Power Supply . . . . . . . 22
2.3.5 Installing A Swappable Power Supply . . . . . . . . 23
2.3.6 Spare Power-Supply Modules . . . . . . . . . . . . 23
2.4 The Swappable Hard Drives (Optional) . . . . . . . . . . . . . 23
2.4.1 The Swappable Hard Drives . . . . . . . . . . . . . 24
2.4.2 Removing A Hard Drive . . . . . . . . . . . . . . . 26
2.4.3 Installing A New Hard Drive . . . . . . . . . . . . . 27
2.4.4 Spare Drive Carriers . . . . . . . . . . . . . . . . . 28
2.6 Arrangement And Length Of Cables . . . . . . . . . . . . . . 31
2.6.1 Distance To System Devices . . . . . . . . . . . . . 32
2.6.2 Cable Considerations For Each Type Of Connection. 32
2.7 Connecting To Base Stations And Host Computers . . . . . . . 33
2.7.1 Connecting To Psion Teklogix Base Stations. . . . . 33
2.7.2 Connecting To Host Computers . . . . . . . . . . . 33
Psion Teklogix 9500 Communications Server User Manual
13
Chapter 2: The Hardware
Introducing The Hardware
2.1 Introducing The Hardware
The Psion Teklogix 9500 Communications Server hardware is packaged in an industrial-grade chassis. Options include redundant power-supplies and redundant hard-disks.
2.1.1 The Front Of The 9500 CommServer
The 9500 CommServer is packaged in a 4U rack-mount case with a flip-down door.
At the left are (from top to bottom) a disk-access indicator, a lock for the door, the reset switch, the power-on switch, and a power-on indicator.
Figure 2.1 The Front (Door Closed)
The front panel contains several controls and indicators:
Disk Activity
Indicator
Door Lock
Reset Switch
Power Switch
Figure 2.2 Front-Panel Controls Of The CommServer
Psion Teklogix 9500 Communications Server User Manual
15
Chapter 2: The Hardware
The Front Of The 9500 CommServer
From top to bottom, these are as follows:
• Disk activity indicator.
• Door lock.
• Reset switch.
• Power switch.
• Power-on indicator.
Notes:
1. The disk activity indicator lights if there is activity on any installed hard drive.
2. The power-on indicator lights if there is any power present. If the redundant swappable power supplies are installed, this indicator will light if there is power to either or both of the installed power supplies.
Figure 2.3 The Front Panel With Door Open (No RAID Disk Array)
The door of the CommServer opens downward. To open the door, unlock it, then push the two latches together.
16
Psion Teklogix 9500 Communications Server User Manual
Chapter 2: The Hardware
The Back Of The 9500 CommServer
Behind the door are (from left to right) an access panel for the air filter, and the CD drive. If the swappable hard drives are present, they are at the right, below the CD
drive. See Section 2.4.1 on page 24 for more information about the swappable hard
drives.
The air filter on the front panel can be removed for cleaning.
2.1.2 The Back Of The 9500 CommServer
The back of the 9500 CommServer houses the unit’s connectors. At the left is the power supply. In the centre are the connectors to the unit’s motherboard . The motherboard connections include the serial port (COM 1) used for the diagnostic dialup connection from a remote computer. At the right are the unit’s expansion slots. Here the second serial port, COM2 (used for the direct cable connection to a diagnostic PC), and the optional second Ethernet card are located.
Figure 2.4 The Back Of The 9500 CommServer (Single Power Supply)
For the version with dual swappable power-supplies, both power-supplies are located at the left, one above the other.
Figure 2.5 The Back Of The CommServer (Dual Swappable Power Supply)
Psion Teklogix 9500 Communications Server User Manual
17
Chapter 2: The Hardware
Choosing A Location For The CommServer
2.2 Choosing A Location For The CommServer
This chapter provides guidelines for choosing a location for the 9500 CommServer, using cables, and connecting external devices.
The main considerations for installing the CommServer are:
1. Connecting it to the host computer.
2. Connecting it to the bases.
3. Plugging it into an AC power source.
Usually, Psion Teklogix recommends the locations for the CommServer and bases as a result of a site survey. Several factors are considered when choosing a location for the CommServer. These factors include: environmental requirements, power requirements, and the distance to system devices.
The CommServer should be installed in a location that is free from direct heat, excessive moisture, dust and vibration. For proper operation, do not exceed the
environmental requirements listed in the specifications (see Chapter 13:
).
2.3 The Power Supply
2.3.1 Power Requirements
Warning: To avoid electric shock, the power cord’s protective grounding conductor must always be connected to ground.
The CommServer should be connected directly to a standard 3-wire grounded AC outlet that will not be accidentally turned off.
The CommServer has some AC line filtering that will reduce the potential for damage from transients. Usually, no additional protection is required.
18
Psion Teklogix 9500 Communications Server User Manual
Chapter 2: The Hardware
Power Requirements
The Power Switch
Warning: The On/Off power switch on the front of the CommServer is NOT an AC power switch. To remove AC power from the CommServer you must unplug the AC power cord(s) from the wall outlet or power supply.
To change the operating state of the CommServer, press the front-panel Power switch firmly for one second, then release.
Failure of the CommServer to react to a press of the front-panel Power switch may occur due to software or hardware malfunction. In these cases, temporarily switching off the CommServer’s power-supplies through their switches on the rear panel, or temporarily unplugging the AC cord(s) from the AC source for 5 seconds, will cause a hard reboot. The CommServer can then start normally.
The rear-panel switches also allows one of the redundant power-supplies to be switched off and removed, while the other continues to power the CommServer. See
“The Redundant Power Supply (Optional)” on page E-21 for details.
Supply Voltages And Frequencies
The CommServer can operate from an AC supply of 90-264 V, at a frequency of 47 to 63 Hz.
Power Cords
Your CommServer may be supplied with a North American power cord, a European power cord, or a power cord intended for another country. The Psion Teklogix factory can supply power cords with the following part numbers:
Area Of Use Psion Teklogix Part Number
North America 93351
Continental Europe 93159
Psion Teklogix 9500 Communications Server User Manual
19
Chapter 2: The Hardware
Power Requirements
In some cases, the installer may need to obtain a power cord with the wall plug compatible with country or region. In these cases, the AC cord must be selected to meet the following criteria:
• The AC plug must be terminated in a grounding type plug designed for use in your region.
• The plugs must be marked to indicate they have been certified by an agency acceptable in your region.
• For use in Europe, the cable part of cord must be marked with <HAR> or VDE.
• The cord must be rated for the AC voltage available in your region.
• The cord must be rated for current rating of 8 A for 115VAC or 6 A for
220VAC.
• The cord length must be less than 4.5 metres (14.8 feet).
Ground Potentials
The possibility of differences in ground potential between the CommServer and external devices should be considered. This ground potential problem is most likely in locations that have large loads on the AC power system (roller mills, electric furnaces, etc.).
Differences in ground potential can cause difficulty in communication, noise sensitivity, and in severe cases, component damage. Please consult with a Psion
Teklogix Technical Support Analyst if there is a possibility of ground potential problems.
To avoid ground potential problems, connect the CommServer to the same power source as the host computer or modem with which it will communicate. Ways to avoid ground potential problems are listed here in order of effectiveness:
1. Use the same outlet box.
2. Use the same circuit breaker panel.
3. Use the same step-down transformer/voltage distribution panel.
4. Use the same building distribution system.
20
Psion Teklogix 9500 Communications Server User Manual
Chapter 2: The Hardware
The Single Power Supply
2.3.2 The Single Power Supply
The standard model of the hardware CommServer includes a single fixed power supply.
Figure 2.6 The Single Power Supply
2.3.3 The Redundant Power Supply (Optional)
The hardware CommServer can include an optional redundant (‘swappable’) power supply. This power supply consists of two modules, each of which can power the
CommServer by itself. Both modules normally remain on. If one module has a problem, it can be turned off and replaced, while the other module continues to power the CommServer.
Handle
Power connector
Thumbscrew
Alarm silence switch
Power switch
Figure 2.7 The Swappable Power Supply
Psion Teklogix 9500 Communications Server User Manual
21
Chapter 2: The Hardware
Removing A Swappable Power Supply
The power switch on the front of the CommServer controls the power from both modules. Each module has its own power switch at the rear, by which it can be turned off for removal.
When a power-supply module is turned off, the CommServer sounds an alarm. This alarm continues until the module (or a replacement module) is reinserted and turned back on. The alarm can be silenced by pressing the alarm silence switch, the small red button next to the upper power supply.
2.3.4 Removing A Swappable Power Supply
Each power-supply can be removed separately. If both supplies are removed, the
CommServer will cease to function.
Figure 2.8 Removing A Power Supply
To remove a power supply:
Warning: Make sure the power supply is switched off before removing it!
1. Turn off the power supply. The power alarm sounds.
Note: The alarm may be silenced by pressing the red button next to the upper power supply.
2. Disconnect the power cord.
3. Unscrew the thumbscrew.
4. Pull the handle. The power supply slides out.
22
Psion Teklogix 9500 Communications Server User Manual
Chapter 2: The Hardware
Installing A Swappable Power Supply
2.3.5 Installing A Swappable Power Supply
Figure 2.9 Inserting A Power Supply Module
To install a power supply module:
Warning: Make sure the new power supply module is switched off before inserting it!
1. Slide the power supply in until it stops.
2. Fasten the thumbscrew.
3. Plug in the power cord.
4. Turn the new power supply on.
2.3.6 Spare Power-Supply Modules
Replacement power-supply modules may be obtained from Psion Teklogix. The part number is 9003142.
2.4 The Swappable Hard Drives (Optional)
The CommServer can include a RAID-1 hard-drive subsystem. RAID-1 keeps identical copies of the contents of the CommServer’s system hard drive on each of multiple swappable hard drives.If one RAID-1 drive fails, the identical information
Psion Teklogix 9500 Communications Server User Manual
23
Chapter 2: The Hardware
The Swappable Hard Drives
on another drive is used while the first drive is replaced.This is called ‘mirroring’.
The CommServer is configured to keep the information on both drives in synchronisation. If one of the hard drives is replaced, the CommServer automatically rebuilds the information on the replacement drive from the copy on the other drive.
The CommServer’s RAID-1 hard-drive subsystem is contained in two swappable hard drives which are accessible from the front of the CommServer. Both of these hard drives are identical models.
The lower hard drive is on RAID channel 1; the upper hard drive is on RAID channel 2. These channels are used to identify the drives in the RAID configuration
and monitoring software. See “Disk Array Administration” on page 103 for details
on using this software.
2.4.1 The Swappable Hard Drives
Figure 2.10 Front Of 9500 Showing Swappable Hard Drives
The swappable hard drives are accessible through the front panel of the
CommServer. Each hard drive is housed in a removable ‘carrier’, which slides into the CommServer’s drive bay.
24
Psion Teklogix 9500 Communications Server User Manual
Chapter 2: The Hardware
The Swappable Hard Drives
The drive bays appear as follows:
Drive On RAID Channel 2
Drive Removal Lock
Drive Activity Indicator
Status Indicator
Drive On RAID Channel 1
Figure 2.11 Features Of Drive Bays
The left-hand LED on each drive carrier indicate the status of the hard drive inside, as follows:
Colour Of Status LED
Green
Orange
Red
Black (dark)
Meaning
The drive is working normally.
The drive-controller is rebuilding the data on the drive. Until the data on the drive is rebuilt, only one drive is available for storage, and there is no redundancy protection.
The drive is bad or has failed, and is now offline. Only one drive is available for storage, and there is no redundancy protection.
No drive is detected, or there is no power to the drive housing.
The right-hand LED flashes when there is drive activity.
Psion Teklogix 9500 Communications Server User Manual
25
Chapter 2: The Hardware
Removing A Hard Drive
2.4.2 Removing A Hard Drive
The swappable hard drives are designed to be removed while the CommServer is powered up.
Figure 2.12 A Hard Drive Carrier Partially Removed From The CommServer
To remove a hard drive (in its carrier) from the CommServer:
1. Using the provided key, unlock the drive carrier by turning the key in the lock 90° counterclockwise. The indicators on the drive bay go dark, showing that power has been removed from the drive.
2. Pull the drive lever outward. The lever pushes the drive partway out of the bay. It can be pulled all the way out by hand.
The hard drive in its carrier is now free of the CommServer.
To remove the hard drive from the drive carrier:
1. On the right side of the drive carrier, press the small plastic tab slightly inwards. The cover of the drive carrier is released.
2. Slide the cover off the carrier.
3. Remove the screws securing the hard drive to the carrier.
4. Place your hand over the loose hard drive.
26
Psion Teklogix 9500 Communications Server User Manual
Chapter 2: The Hardware
Installing A New Hard Drive
5. Turn the hard drive carrier over, allowing the drive to drop against your hand.
6. Gently grasp the hard drive and turn the drive carrier back over.
7. Pivot the drive away from the carrier. The drive connectors are now accessible.
8. Disconnect the carrier’s power cable from the hard drive.
9. Disconnect the drive from the carrier’s data connector. The hard drive is now free.
2.4.3 Installing A New Hard Drive
The new hard drive must first be inserted on the carrier.
To insert the new hard drive in the drive carrier:
1. On the left side of the drive carrier, press the small plastic tab slightly inwards. The cover of the drive carrier is released.
2. Slide the cover off the carrier.
3. Pivot the carrier’s connector board outwards.
4. Connect the drive carrier’s power cable to the hard drive’s power connector.
5. Connect the drive’s data connector to the connector board’s data connector.
6. Pivot the hard drive until it drops into the drive carrier. There are two pads inside the carrier that help to cushion the hard drive as it enters the carrier.
7. Install four screws (two on either side of the hard drive, or four on the bottom) to secure the hard drive in the drive carrier. You may need to press gently on the hard drive to align the screw holes with the holes in the drive carrier.
8. Replace the drive carrier access cover. It latches back into place.
Psion Teklogix 9500 Communications Server User Manual
27
Chapter 2: The Hardware
Spare Drive Carriers
To replace the hard drive carrier in the CommServer:
1. Slide the drive carrier back into the drive bay. The carrier will latch back into place when the handle is pushed back in.
2. Lock the carrier into place by turning the key in the lock
90° clockwise. Power reaches the hard drive after the lock is turned, and the status indicator lights.
2.4.4 Spare Drive Carriers
Spare or replacement hard-drive carriers can be purchased from Psion Teklogix. The part number (without hard-drive) is 9003142.
2.5 Connecting To External Devices
This section contains general guidelines for connecting the CommServer to external devices such as base stations, host computers, web terminals, and text display terminals.
The back panel of the CommServer houses the unit’s power and communications connections. Since it is built with standard PC components, the CommServer’s hardware has standard PC ports available. However, it is configured at the factory to operate without mouse, keyboard or monitor.
Once the CommServer is installed, its operation can be monitored through a Web browser running on a computer connected to the CommServer through a network; through the diagnostic modem installed on COM1; or through a Dial-up Direct
Connect serial cable on COM2.
28
Psion Teklogix 9500 Communications Server User Manual
2.5.1 The Back Panel Of The Controller
Chapter 2: The Hardware
The Back Panel Of The Controller
AC Power Inlet
Expansion-card Slots
Keyboard Port
Mouse Port
Ethernet Port (onboard)
0
Serial Port 2 (COM2 For Local Access)
Monitor Port Parallel Port
Serial Port 1 (COM1 For Access Through Diagnostic Modem)
Figure 2.13 Location Of Rear Ports (Single Power Supply)
AC Power Inlets
Expansion-card Slots
Keyboard Port
Mouse Port
Ethernet Port (onboard)
Parallel Port
Monitor Port
Serial Port 2 (COM2 For Local Access)
Serial Port 1 (COM1 For Access Through Diagnostic Modem)
Figure 2.14 Location Of Rear Ports (Swappable Power Supply)
Psion Teklogix 9500 Communications Server User Manual
29
Chapter 2: The Hardware
The Serial Ports
The CommServer has a number of ports on its rear panel. The most important ports are the on-board Ethernet port and the serial ports:
• The on-board Ethernet port is built in to the CommServer’s motherboard, and is present on every unit. Through this port, the CommServer can connect to Ethernet networks at 10 or 100 megabits per second.
An additional Ethernet port can be provided for the CommServer on an add-in card.
• The first serial port, COM1, is configured for a serial connection using a diagnostic modem. The remote computer can then use the CommServer’s
Remote Access Server and Windows Terminal Service to access the
CommServer’s desktop interface for maintenance tasks. See Section 2.5.2 on page 30 for details.
• The second serial port, COM2, is used for a local serial connection to another computer. It has the same capabilities as COM1, but is configured
for a Dial-up Direct connection. See Section 2.5.2 on page 30 for details.
An individual system may not have all external devices described here. There are also a parallel port and ports for a VGA monitor, a PS/2-style mouse and a PS/2style keyboard. These ports are only used during maintenance.
Note: The CommServer hardware also has a universal serial bus (USB) port and three audio ports; these are not used by the CommServer.
2.5.2 The Serial Ports
The CommServer carries two serial ports which are intended for a console-port connection to another computer. These connections use TCP/IP over a point-topoint protocol (PPP) serial link; they are intended for local access to the
CommServer by web browsers, telnet clients, and other programs.
The connectors for these parts are standard 9-pin PC-style ‘D’-connectors.
The COM1 port is configured for a modem.
A cable is necessary to connect the COM2 port to the other computer. Psion
Teklogix offers a null-modem cable for this connection. This cable is described in
Appendix A, “Ports, Pinouts And Cable Diagrams.”
A description of the CommServer’s web interface can be found in Appendix C,
“The 9500 CommServer’s Web Interface.” .
30
Psion Teklogix 9500 Communications Server User Manual
Chapter 2: The Hardware
The Network Cards
Commands for the CommServer’s text-mode telnet console can be found in
2.5.3 The Network Cards
The CommServer can be provided with a second Ethernet port. The Ethernet port is provided on an expansion card that fits in one of the PCI expansion slots provided in the CommServer. Several of these slots may be taken up with cards for other options in the CommServer, for example the RAID-controller card.
Expansion-Card Slots (PCI)
COM2 Serial-Port Connector
Figure 2.15 Locations Of The Controller’s Expansion Slots
The locations of the expansion-card slots are shown in Figure 2.15. Expansion cards
are installed at the Psion Teklogix factory or at Psion Teklogix service centres.
The Ethernet Card
The second Ethernet card, which uses an expansion slot, supports 10Base-T connections. Only the CommServer’s onboard Ethernet supports 100-BaseT connections.
2.6 Arrangement And Length Of Cables
Space should be provided around the back panel for cables connecting to the
CommServer. Route the cables away from the air inlet for the ventilation fan. The cables should be placed where they cannot be damaged, preferably in cable trays or conduits. Carefully attach each cable to its designated connector, and gently tighten the small screws that hold the connector shell to the enclosure.
Psion Teklogix 9500 Communications Server User Manual
31
Chapter 2: The Hardware
Distance To System Devices
Short lengths of the required cables are shipped with the system. If the supplied cables are shorter than necessary, they may be extended within the limits outlined below by splicing in additional cable. The cable diagrams in Appendix A, “Ports,
Pinouts And Cable Diagrams” show the electrical configuration of each cable.
When maximum cable lengths are given they are only a guide. The use of special low capacitance cable may permit longer lengths. Long cables should be adequately protected against induced electrical noise and lightning strikes. Electrical noise could degrade system performance while lightning strikes could damage the devices connected to the line.
2.6.1 Distance To System Devices
Direct connection to a host computer often permits high signalling rates; this means that the CommServer benefits from being located close to the host. Connection via communication equipment may require installation close to existing line facilities.
The choice of location for the radio equipment is dictated by site radio coverage requirements. The location of the CommServer should minimize the lengths of cables, especially if long distances would require additional communication equipment.
2.6.2 Cable Considerations For Each Type Of Connection
Each method for connection has different advantages or capabilities.
Ethernet
An Ethernet connection is provided on the CommServer’s motherboard, and an additional Ethernet connection can also be provided on an add-in card. These connect the CommServer to Ethernet networks. Several host computers, 9140s, or
CommServers can be connected to an Ethernet network.
There are two types of Ethernet connections available for the CommServer:
• 10Base-T (using twisted pair cable, an RJ45 connector, 10 Mb/s).
• 100Base-T (using category-5 twisted pair cable, an RJ45 connector,
100 Mb/s).
The maximum cable segment lengths allowed between repeaters for each type of
connection are shown in Table 2.16:
32
Psion Teklogix 9500 Communications Server User Manual
Chapter 2: The Hardware
Connecting To Base Stations And Host Computers
Ethernet Cabling
10Base-T *
100Base-T
* With 24 AWG wire
Maximum Length
100 m
100 m
Table 2.16 Maximum Cable Lengths For Ethernet
2.7 Connecting To Base Stations And Host Computers
2.7.1 Connecting To Psion Teklogix Base Stations
See Chapter 12: “Connecting To Bases” for information about connecting the
CommServer to your Psion Teklogix base stations.
2.7.2 Connecting To Host Computers
Many hosts can be connected over Ethernet. Consult the specific sections of
Chapter 6: “Set-Up For ANSI Emulation” ,
, Chapter 9: “Set-Up For 5250 Emulation” , and
for information about connecting the CommServer to your host.
Psion Teklogix 9500 Communications Server User Manual
33
T
HE
9500’
S
S
OFTWARE
3.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.1.1 Server Requirements . . . . . . . . . . . . . . . . . 37
3.2 Setting Up The Software. . . . . . . . . . . . . . . . . . . . . 38
3.2.1 Configuring The OS Before Installation . . . . . . . 38
3.2.2 Additional Configuration . . . . . . . . . . . . . . . 39
3.2.3 Installing The Java Runtime Engine . . . . . . . . . 39
3.2.4 Registering The 9500 CommServer Software . . . . 41
3.2.5 Installing The Server Software . . . . . . . . . . . . 42
3.2.6 Backing Up The System State . . . . . . . . . . . . 53
3.2.7 Restoring The System State. . . . . . . . . . . . . . 56
3.2.8 Uninstalling The Communications Server Software . 60
3
Psion Teklogix 9500 Communications Server User Manual
35
Chapter 3: The 9500’s Software
Introduction
3.1 Introduction
This chapter covers the installation of Psion Teklogix’ Communications Server software on the customer’s own machine. The software requires the Windows 2000 or Windows 2003 Server operating system. The software must be installed in a specific order, with certain options chosen. To start from an empty system:
1. Install the Windows 2003 Server or Windows 2000 operating system.
2. Enable the following Windows features: Windows Terminal
Service, HTTP server, Telnet server, SNMP.
3. Install the Psion Teklogix Communications Server software.
3.1.1 Server Requirements
The 9500 CommServer software requires a server of the following specifications:
Hardware
• Pentium III or IV processor.
• 512 MB main memory.
• EIDE hard drive interface for two devices.
• Two serial RS-232 ports.
• Ethernet port (10Base-T or 100Base-T)
• Keyboard port.
• Mouse port.
• VGA monitor port.
Optional Hardware:
• Second Ethernet card.
Software
• Operating system: Microsoft Windows 2000 or Windows 2003 Server.
• Sun Java Runtime Engine 1.2.2 or higher
Psion Teklogix 9500 Communications Server User Manual
37
Chapter 3: The 9500’s Software
Setting Up The Software
3.2 Setting Up The Software
3.2.1 Configuring The OS Before Installation
In order to work with the Psion Teklogix Communications Server software,
Windows requires certain utilities to be installed. These include:
• Accessory & Utilities.
• Indexing Service.
• Internet Information Services (IIS) (the FTP server, HTML, SMTP, web server).
• Management & Monitoring (SNMP, and Network Monitoring).
• Message Queue.
• Network Services (COM Proxy, DNS, DHCP, Internet Authentication
Server, QoS, TCP, WINS).
• Script Debugger.
• Terminal Services.
• Windows Media Services.
These utilities support the following services:
• Windows Terminal Service, to support remote access to the Windows desktop interface.
• RAS Server, to support remote connections to the machine.
• Web Server, to serve the pages of the CommServer’s Communications
Server configuration web interface.
• Telnet Server, to support text connections to the CommServer’s commandline interfaces.
• SNMP Services, to support SNMP management of the CommServer.
38
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Additional Configuration
3.2.2 Additional Configuration
Some additional steps should be taken to configure your 9500 Communications
Server software and its server:
• Set the computer name to be unique on your network. The default is
PSION-xxx. This setting is accessible through Start, Control Panel,
System, Network Identification.
• Set IP parameters if you are not using DHCP to obtain an IP address. These settings are accessible through Start, Settings, Network & Dial-up
Connection, Local Area Connection, Properties.
• Assign a password to the Administrator user account. User accounts are accessible through Start, Settings, Administration Tools, Computer
Management, Local Users & Groups.
Important: The Administrator account is provided without a default password. Psion Teklogix strongly recommends that one be assigned.
A Support account exists for use by Psion Teklogix support personnel. This account can be disabled, but Psion Teklogix does not recommend this.
• Set time and time zone through Start, Control Panel, Date/Time. The default time zone is North American “Eastern Standard Time” (UTC -5)
3.2.3 Installing The Java Runtime Engine
The CommServer requires the Java 2 Runtime Engine, version 1.2 or higher. This software may already be present on your server. If not, it may be installed from the
Communications Server CD:
1. Insert the Communications Server CD.
2. Start a browser.
Psion Teklogix 9500 Communications Server User Manual
39
Chapter 3: The 9500’s Software
Installing The Java Runtime Engine
3. Open the page
setup.htm
on the CD. It appears as follows:
This screen presents a number of options, including links to the Communications Server manual.
40
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Registering The 9500 CommServer Software
4. Click on the Install Now link next to Java 2 Runtime Environment
v1.3.1. The introduction screen for installing the Runtime Engine software appears:
5. Follow the instructions on this screen to start the installer.
6. Follow the installer’s instructions to install the Java software.
3.2.4 Registering The 9500 CommServer Software
The Psion Teklogix Communications Server software requires registration during its installation.
The software is supplied with a serial number. During installation, it accepts this serial number and creates a Customer Key. To continue installation, the customer must contact Psion Teklogix, and provide the Customer Key.
Psion Teklogix uses the Customer Key to create a machine-specific License Key that will unlock the program.
Psion Teklogix 9500 Communications Server User Manual
41
Chapter 3: The 9500’s Software
Installing The Server Software
Psion Teklogix can be contacted by voice at:
1-800-387-8898 (from Canada and the USA),
+1 905 812 6380 (from outside Canada and the USA), by fax at:
+1 905 812 6374 by email at:
or on the Web at:
http://www.psionteklogix.com/teknet/ service/hd/license.aspx
Please address your email to ‘CommServer Registration’, and include your
Customer Key, serial number, name, and telephone number.
3.2.5 Installing The Server Software
To install Psion Teklogix Communications Server software:
Important: Make sure that the required Java Runtime Engine software is installed first!
1. Insert the Communications Server CD.
2. Start a browser.
42
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Installing The Server Software
3. Open the file
setup.htm
on the CD. It appears as follows:
This screen presents a number of options, including links to the 9500
Communications Server manual.
Psion Teklogix 9500 Communications Server User Manual
43
Chapter 3: The 9500’s Software
Installing The Server Software
4. Click on the Install Now link next to PTX Communication Server. The introduction screen for installing the Communications Server software appears:
5. Follow the instructions on this screen to start the installation.
44
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Installing The Server Software
When the installation begins, the following dialog box appears:
6. Press the Yes button to continue installation. The installer starts and presents the introductory install screen.
7. Click Next to continue. At any time, you can press the Cancel button to abandon the installation process.
Psion Teklogix 9500 Communications Server User Manual
45
Chapter 3: The 9500’s Software
Installing The Server Software
The license screen appears as follows:
8. Select I accept to enable the Next button.
46
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Installing The Server Software
9. Press the Next button. The installer displays the serial-number screen:
This serial-number screen and the following screens (Step 9 to Step 15) are only displayed when the software-only version of the CommServer is being installed on non-Psion Teklogix hardware. It is not necessary to re-enter the serial number or Customer Key during upgrades to hardware-based CommServers.
10. Enter the serial number which you received with the Communications
Server package. The serial number is a 12-character alphanumeric string (earlier versions of the software had a numeric string).
Important: If you enter an incorrect serial number, you must close the installer and restart it to clear the incorrect serial number from the intaller’s memory.
Psion Teklogix 9500 Communications Server User Manual
47
Chapter 3: The 9500’s Software
Installing The Server Software
11. Press Next. The installer calculates a Customer Key, a sequence of twenty decimal numbers.
12. Give the Customer Key to Psion Teklogix. (See page 41 for contact
details.) Psion Teklogix will use the customer key to create a machinespecific License Key that will unlock the program.
13. Press Next. The installer displays the License Key screen:
48
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Installing The Server Software
14. Enter the License Key (proivided by Psion Teklogix) into the textboxes.
15. Press Next. The installer checks the License Key. If it is correct, the installer displays a confirmation screen.
16. Press Next. The installer displays a screen requesting an installation location for the software:
Note: This screen is displayed only when installing the CommServer software on new hardware. If the installer finds a previously-existing installation of the Communications Server software, it will automatically install the upgrade there.
17. Press Next. The installer checks for certain required software on your system (for example, the IBM SNA communications software, the
Windows SNMP service, and the Microsoft IIS web server). It asks for confirmation to proceed if these are not found.
Psion Teklogix 9500 Communications Server User Manual
49
Chapter 3: The 9500’s Software
Installing The Server Software
When it is ready to install the CommServer software, the installer displays a summary screen detailing the changes to be made:
18. Press Next to continue. The installer displays a progress screen:
50
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Installing The Server Software
When the Communications Server software is installed, the installer asks whether you would like to start it:
19. Choose Now or Later, then press Next. If Now is selected, the installer starts the software immediately. If Later is selected, the software will start as a service after the next reboot.
Psion Teklogix 9500 Communications Server User Manual
51
Chapter 3: The 9500’s Software
Installing The Server Software
The installer then displays the Readme file, which gives information on configuring the system:
20. Press Next to continue. The installer then asks whether you would like to reboot the system:
52
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Backing Up The System State
Select Yes if you want to reboot immediately, or No to continue without rebooting.
21. Press Finish to continue. The installer dialogue disappears.
The Communications Server software is now installed.
3.2.6 Backing Up The System State
Psion Teklogix recommends that the administrator of the server running the
Communications Server software backup the server’s system state after installation.
To do this:
1. Select Start, Programs, Accessories, System Tools, Backup. The
Backup and Recovery Tools dialog box appears:
2. Select the Backup tab.
Psion Teklogix 9500 Communications Server User Manual
53
Chapter 3: The 9500’s Software
Backing Up The System State
3. Select the System State check box. The dialog box changes to appear as follows, with a listing of system components that will be backed up:
4. Enter a filename for the backup file.
5. Click the Start Backup button. The Backup Job Information dialog box appears:
54
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Backing Up The System State
6. Press the Start Backup button. The Backup Progress dialog box appears:
7. When the backup is complete, the dialog box changes:
Press Close to dismiss this dialog box.
Psion Teklogix 9500 Communications Server User Manual
55
Chapter 3: The 9500’s Software
Restoring The System State
3.2.7 Restoring The System State
To restore the server’s system state:
1. Select Start, Programs, Accessories, System Tools, Backup. The
Backup and Recovery Tools dialog box appears:
2. Select the Restore tab. A listing of available properties appears in the tree at the left.
56
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Restoring The System State
3. Select the System State check box. The dialog box changes to appear as follows, with a listing of the system components that will be restored:
4. Click the Start Restore button. The System State Warning appears:
Note: The text of this warning reads, “Restoring System State will always overwrite current System State unless restoring to an alternate location.”
Psion Teklogix 9500 Communications Server User Manual
57
Chapter 3: The 9500’s Software
Restoring The System State
5. Press the OK button to replace the existing system state with that in the restore file.
6. Press the OK button. The Select Backup File dialog box appears:
7. Enter the name of the backup file which you want to restore from.
58
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Restoring The System State
8. Press the OK button. The Restore Progress dialog box appears:
9. When the restore is complete, the dialog box changes:
Press Close to dismiss this dialog box.
Psion Teklogix 9500 Communications Server User Manual
59
Chapter 3: The 9500’s Software
Uninstalling The Communications Server Software
3.2.8 Uninstalling The Communications Server Software
1. Select Start, Settings, Control Panel. The Control Panel window appears:
2. Double-click on Add/Remove Programs. A window appears listing installed software.
3. Select the PTX Communication Server item. When it is selected, it becomes highlighted, and a Change/Remove button appears:
60
Psion Teklogix 9500 Communications Server User Manual
Chapter 3: The 9500’s Software
Uninstalling The Communications Server Software
4. Press the Change/Remove button. The Communications Server uninstaller starts and presents the introductory uninstall screen:
5. Press Next to continue. The uninstaller provides a summary screen listing the software that will be uninstalled:
Psion Teklogix 9500 Communications Server User Manual
61
6. Press Next to continue. The uninstaller removes the software, displaying a progress screen:
7. When the software is removed, the uninstaller displays a completion screen:
Chapter 3: The 9500’s Software
Uninstalling The Communications Server Software
8. Press Next. The uninstaller asks whether you would like to reboot:
Select Yes if you want to reboot immediately, or No to continue without reboot.
9. Press Next to continue. The uninstaller displays a completion screen:
The Psion Teklogix Communications Server software is now uninstalled.
Psion Teklogix 9500 Communications Server User Manual
63
C
ONNECTING
T
O
T
HE
C
OMM
S
ERVER
4
4.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
4.2 The Web Interface . . . . . . . . . . . . . . . . . . . . . . . . 68
4.2.1 Connecting Locally . . . . . . . . . . . . . . . . . . 68
4.2.2 Connecting Remotely . . . . . . . . . . . . . . . . . 68
4.3 The OS Desktop . . . . . . . . . . . . . . . . . . . . . . . . . 69
4.3.1 Connecting Locally . . . . . . . . . . . . . . . . . . 69
4.3.2 Connecting Remotely . . . . . . . . . . . . . . . . . 70
4.3.3 Configuring The CommServer’s WTS Server . . . . 70
4.3.4 The WTS Standalone Client . . . . . . . . . . . . . 70
4.3.4.1 Installation . . . . . . . . . . . . . . . . . . . . 71
4.3.4.2 Connecting To The Desktop . . . . . . . . . . . 71
4.3.5 The WTS Browser Client . . . . . . . . . . . . . . . 72
4.3.5.1 Connecting To The Desktop . . . . . . . . . . . 72
4.4 The Network Console . . . . . . . . . . . . . . . . . . . . . . 73
4.4.1 Connecting Locally . . . . . . . . . . . . . . . . . . 73
4.4.2 Connecting Remotely . . . . . . . . . . . . . . . . . 73
4.4.3 Network Console Authentication . . . . . . . . . . . 74
4.4.3.1 Authentication For The PPP Connection . . . . 75
4.4.3.2 Telnet Authentication . . . . . . . . . . . . . . 75
4.5 The Windows OS Prompt . . . . . . . . . . . . . . . . . . . . 77
4.5.1 Connecting Locally . . . . . . . . . . . . . . . . . . 77
4.5.2 Connecting Remotely . . . . . . . . . . . . . . . . . 77
4.6 The Serial Ports . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.6.1 Connecting To The Serial Ports. . . . . . . . . . . . 78
4.6.2 Setting Up A Modem Connection . . . . . . . . . . 80
Psion Teklogix 9500 Communications Server User Manual
65
Chapter 4: Connecting To The CommServer
Introduction
4.1 Introduction
The CommServer has a number of interfaces for its management.
• The Psion Teklogix web interface.
The major interface for configuring the Psion Teklogix emulation software resident in the CommServer is a web interface. The CommServer provides an HTTP server on port 8008. Browsers may connect to this port to display the web interface.
See “The Web Interface” on page 68 for details.
• The OS desktop.
Certain administrative functions of the CommServer require access to the operating system’s desktop interface. These functions include:
• Configuration of Windows services.
• Configuration of the power-supply-monitoring software.
• Configuration of IBM Personal Communications software, for
SNA connectivity.
• Monitoring of the CommServer’s RAID system.
• Viewing of OS logfiles.
See “Administering The CommServer” on page 81 for more details on
these administrative functions. In addition, the standard features of the operating system are available from the desktop.
The desktop interface may be displayed locally or remotely.
See “Connecting Locally” on page 69 for details on connecting a display,
keyboard, and mouse directly to the CommServer.
For displaying the desktop interface remotely, Windows provides a
Terminal Server service, to which a client program on another machine can connect, using Remote Desktop Protocol. The desktop interface of the
CommServer is then displayed on the remote machine.
Psion Teklogix 9500 Communications Server User Manual
67
Chapter 4: Connecting To The CommServer
The Web Interface
See “Connecting Remotely” on page 70 for details on connecting to the
desktop from a remote computer.
• The console.
The CommServer provides a text-mode interface to its Psion Teklogix software for configuration and maintenance. This interface is called the
‘network console’.
See “The Network Console” on page 73 for methods of connecting to the
network console.
• The OS prompt.
The CommServer’s OS prompt is accessible through the usual methods from the desktop interface. However, it is also accessible through a telnet connection, using Windows Telnet Server.
See “The Windows OS Prompt” on page 77 for details.
4.2 The Web Interface
The CommServer’s emulation software is configured through a web interface.
Details on the screens of the CommServer’s web interface are given in Appendix C,
“The 9500 CommServer’s Web Interface.”
4.2.1 Connecting Locally
The web interface may be viewed locally, from the CommServer’s desktop interface, by directing the CommServer’s own browser to http://localhost:8008/
4.2.2 Connecting Remotely
To connect to the CommServer’s web interface over the IP network (Ethernet or
PPP), direct a browser to http://<IP address>:8008/ where
<IP Address>
indicates the IP address of the CommServer.
Note: This IP address may be on the Ethernet network or on the PPP link.
It uses a non-standard HTTP port number of 8008.
68
Psion Teklogix 9500 Communications Server User Manual
Chapter 4: Connecting To The CommServer
The OS Desktop
4.3 The OS Desktop
Many of the CommServer’s administrative tasks can be handled through its OS
‘desktop’ interface. These tasks include:
• SNMP configuration through SNMP Service properties.
• SNA configuration through IBM Personal Communication software.
• Power-supply alarm configuration through the configuration program for the CommServer’s hardware alarm system.
• Logfile reading through the Windows Event Viewer.
• RAID configuration.
See “Administering The CommServer” on page 81 for details on these tasks.
4.3.1 Connecting Locally
When a local keyboard, mouse, and display are connected to the CommServer, the machine uses these to display its desktop locally.
The CommServer has connectors for attaching external keyboard, mouse, and display.
These connectors are located as follows:
Keyboard
Network
Parallel Port
Mouse
Serial Port 1
Monitor
Figure 4.1 Location Of Connectors
The keyboard and mouse connectors accept standard ‘PS/2-style’ devices.
The display connector is a standard 15-pin analogue VGA connector.
Psion Teklogix 9500 Communications Server User Manual
69
Chapter 4: Connecting To The CommServer
Connecting Remotely
The keyboard, mouse, and display may be connected at any time, but the
CommServer’s OS must be restarted for them to be recognized.
The default display is 800 pixels by 600 pixels using 16 colours.
4.3.2 Connecting Remotely
It may be necessary to reach the CommServer’s desktop from a remote computer.
The CommServer’s desktop may be made remotely-accessible through Windows
Terminal Services (WTS). In this system, a WTS client on a remote machine connects to a WTS server on the CommServer. The client displays the
CommServer’s desktop on the remote machine, and the remote user can operate it as if it were a local display.
The WTS client is available as a standalone program for most varieties of the
Windows OS, and as a plugin for the Internet Explorer browser on Windows.
Operators may connect to the WTS server in several ways:
• Via IP over PPP through serial port 1. This port is configured for PPP access through a modem.
• Via IP over PPP through serial port 2. This port is configured for PPP access by direct cable connection.
• Via IP through the Ethernet network interface.
4.3.3 Configuring The CommServer’s WTS Server
The CommServer’s WTS server is configured as a service. It starts when the
CommServer starts. No other configuration need be done.
4.3.4 The WTS Standalone Client
The Windows Terminal Server in the CommServer communicates with a standalone client program on the remote machine. This program is called Windows Terminal
Services Client. Versions are available for 16-bit and 32-bit versions of the
Windows operating system.
A maximum of two WTS client programs may connect to the CommServer at one time.
70
Psion Teklogix 9500 Communications Server User Manual
Chapter 4: Connecting To The CommServer
The WTS Standalone Client
Windows Terminal Services Client may be present on the remote computer. If not, it can be installed from a local install disk, or from installation files included with the
CommServer. The CommServer is configured to allow remote access to them for installation across the network.
4.3.4.1
Installation
To install Windows Terminal Services Client from the CommServer’s installation files onto a machine running 32-bit Windows:
1. Open Windows Explorer.
2. Map a new drive to
\\<IP Address>\tsclient\ where
<IP Address>
indicates the IP address of the CommServer.
Note: This IP address may be on the Ethernet network or on the PPP link.
3. Open this drive in Windows Explorer. The net
directory appears.
4. Open the net directory. The win32
directory appears.
5. Open the win32
directory. A number of files appear, including the setup.exe
file.
Note: If the ‘hide extensions of known file types’ preference is selected, the name of this file will appear as
setup
. This is the Windows default.
6. Execute the setup.exe
file. The setup process for the Windows Terminal Services Client begins.
7. Follow the setup prompts to install the WTS client.
4.3.4.2
Connecting To The Desktop
To connect to the CommServer using the Windows Terminal Services (WTS) standalone client program:
1. Start WTS Client. The Terminal Services Client window opens.
2. Enter the IP address of the CommServer.
Note: This IP address may be on the Ethernet network or on the PPP link.
Psion Teklogix 9500 Communications Server User Manual
71
Chapter 4: Connecting To The CommServer
The WTS Browser Client
3. Press the Connect button. The WTS client connects to the CommServer and displays the CommServer’s screen. The CommServer requests a user name and password.
Important: The default username is Administrator and there is no password.
Psion Teklogix recommends that the system administrator change these values.
4. Enter the correct user name and password. The WTS client displays the
CommServer’s desktop.
4.3.5 The WTS Browser Client
The CommServer can automatically provide a plugin to users of the Internet
Explorer browser, so that the remote machine’s desktop appears in the browser. This requires Microsoft Internet Explorer version 5 or later, running on Windows.
4.3.5.1
Connecting To The Desktop
To connect to the CommServer using the Windows Terminal Services (WTS) browser plugin:
1. Start the browser.
2. Connect to the page http://<IP Address>:8008/tsweb/ where
<IP Address>
represents the IP address of the CommServer.
Note: This IP address may be on the Ethernet network or on the PPP link.
It uses a non-standard HTTP port number of 8008.
A login page appears.
3. Select a screen size. The CommServer uses an 800-by-600-pixel desktop by default.
4. Press the Connect button. If the browser does not already have the
WTS plugin, the CommServer serves the plugin to the browser. The plugin connects to the CommServer. The CommServer then requests a user name and password.
72
Psion Teklogix 9500 Communications Server User Manual
Chapter 4: Connecting To The CommServer
The Network Console
Important: The default username is Administrator and there is no password.
Psion Teklogix recommends that the system administrator change these values.
5. Enter the correct user name and password. The WTS plugin displays the CommServer’s desktop in the browser.
4.4 The Network Console
The CommServer’s ‘network console’ provides a text-mode interface to the Psion
Teklogix Communications Server software resident in the CommServer.
4.4.1 Connecting Locally
From the CommServer’s desktop interface, the console is available through telnet to localhost port 9523.
Note: Port 9523 is used so that the Psion Teklogix telnet server does not conflict with the Windows telnet server on the standard port 23.
4.4.2 Connecting Remotely
Operators may connect to the CommServer’s network console from other machines in a number of ways:
• Via IP over PPP through serial port 1. This port is configured for PPP access through a modem.
• Via IP over PPP through serial port 2. This port is configured for PPP access by direct cable connection.
• Via IP through the Ethernet network interface.
The CommServer provides an IP address from a pool of 32 addresses, between
192.168.1.1 and 192.168.1.32, to devices connecting serially. The CommServer itself uses 192.168.1.1, and connecting devices receive one of the other addresses.
To set this up:
1. Select Start, Settings, Control Panel. The Control Panel window opens.
Psion Teklogix 9500 Communications Server User Manual
73
Chapter 4: Connecting To The CommServer
Network Console Authentication
2. Select Routing and Remote Access. The Routing and Remote Access window opens. At the left of the window is a ‘tree’ structure.
3. Select the name of the CommServer.
4. Right-click on the name of the CommServer. The Local Properties window for the CommServer opens.
5. Select the IP tab.
6. Enable incoming IP connections by placing a checkmark in the Allow
IP-based Remote Access Connections box.
7. Select the Static Address Pool radiobutton.
8. Press the Add button to add a new entry in the list of address pools. A dialog box opens.
9. Enter a starting address of 192.168.1.1 and 32 for the number of addresses. The ending address will be automatically filled in.
10. Press the OK button. The dialog box disappears.
11. Press the OK button. The Local Properties window disappears.
To connect to the network console, telnet to
<IP address> 9523
where
<IP Address>
indicates the IP address of the CommServer.
Note: Port 9523 is used so that the Psion Teklogix telnet server does not conflict with the Windows telnet server on the standard port 23.
4.4.3 Network Console Authentication
The CommServer may be configured to require authentication for sessions at the network console. This can be done in a number of ways:
• PAP authentication for devices attempting to connect across a PPP link.
• A user name and password for devices attempting a telnet session, across the PPP link or directly through the modem to the COM1 port.
74
Psion Teklogix 9500 Communications Server User Manual
Chapter 4: Connecting To The CommServer
Network Console Authentication
4.4.3.1
Authentication For The PPP Connection
The CommServer may be configured to require PAP authentication for a device attempting to connect by PPP to the COM2 port.
To select this option:
1. Select Start, Settings, Control Panel. The Control Panel window opens.
2. Select Routing and Remote Access. The Routing and Remote Access window opens. At the left of the window is a ‘tree’ structure.
3. Select the name of the CommServer.
4. Right-click on the name of the CommServer. The Local Properties window for the CommServer opens.
5. Select the Security tab.
6. Select Windows Authentication.
7. Press the Authentication Methods button. The Authentication
Methods window opens.
8. Enable PAP authentication by placing a checkmark in the Unencrypted
Password box.
If PAP authentication is enabled, the CommServer requests a username and password from the device attempting to establish the PPP link.
These passwords and usernames are not the same as those used in authorizing telnet
sessions (see the next section on page 75 for details on telnet-session passwords).
4.4.3.2
Telnet Authentication
The CommServer may be configured to require a username and password from each telnet session.
Psion Teklogix 9500 Communications Server User Manual
75
Chapter 4: Connecting To The CommServer
Network Console Authentication
If the Enable Telnet Authentication parameter in the Miscellaneous System Options screen is enabled, the CommServer requests a username and password from telnet sessions connecting to the network console only.
This username and password are not required for other telnet sessions using the PPP port. However, the CommServer may be configured to require a separate username
and password for the PPP connection itself (see the previous section on page 75 for
more details).
When telnet authentication is enabled, the CommServer requests a username when a new network-console session is opened:
>User:
After the user enters a username, the CommServer requests a password:
>User: sue
>Password:
>
After the user enters the correct password, the CommServer displays the network-console prompt:
>User: sue
>Password: ********
>User Logged In
>
76
Psion Teklogix 9500 Communications Server User Manual
Chapter 4: Connecting To The CommServer
The Windows OS Prompt
If the user does not enter a correct username and password, the CommServer displays the message
Unknown Name or Password
and requests another username.
The user names and passwords are those listed in the Users listbox in the
CommServer’s Main Configuration Screen and set in the Create New User and Edit
Existing User screens. They are the same ones used to log into the CommServer’s web interface.
See “System Configuration: Miscellaneous System Options” on page C-177 for more details.
4.5 The Windows OS Prompt
Standard Windows text commands are available at the Windows OS prompt.
4.5.1 Connecting Locally
From the CommServer’s desktop interface, the OS prompt is available through the usual Windows OS interface.
4.5.2 Connecting Remotely
Operators may connect to the CommServer Windows OS prompt through Windows
Telnet Server. It is accessible from other machines in a number of ways:
• Via IP over PPP through serial port 1. This port is configured for PPP access through a modem.
• Via IP over PPP through serial port 2. This port is configured for PPP access by direct cable connection.
• Via IP through the Ethernet network interface.
To connect to the console, telnet to
<IP address> 23
where
<IP Address>
indicates the IP address of the CommServer.
Note: The Windows telnet server uses the standard telnet port of 23. The telnet server for the CommServer’s emulation software uses port 9523 so that it does not conflict with the Windows telnet server.
Psion Teklogix 9500 Communications Server User Manual
77
Chapter 4: Connecting To The CommServer
The Serial Ports
4.6 The Serial Ports
The CommServer has two serial ports, located on the back panel.
COM2
COM1
Figure 4.2 Location Of Serial Ports
The location of the serial ports is the same on both the single-power-supply and the dual-power-supply versions of the CommServer.
Both serial ports supports a Point-to-Point Protocol (PPP) link to temporarily connect an external computer to the CommServer. Once the PPP link is set up, the external computer operates as if it is communicating with the CommServer over a
Ethernet network connection.
Serial port one is configured for a PPP link over a diagnostic modem. The standard settings configure the modem to auto-answer. This serial port uses a 9-pin male
‘D’ connector.
Serial port two is configured for a PPP link over a direct cable connection between the CommServer and another machine. This serial port uses a 9-pin ‘D’ connector.
4.6.1 Connecting To The Serial Ports
The setup on the remote computer is similar to the setup for dial-up access to an
Internet service provider.
Either a direct cable connection or a dial-up modem connection may be used.
78
Psion Teklogix 9500 Communications Server User Manual
Chapter 4: Connecting To The CommServer
Connecting To The Serial Ports
A Direct Cable Connection
web browser, telnet client, or WTS client networking driver networking driver serial line (null-modem cable)
External Computer
serial port serial port
CommServer
web (HTTP) server telnet server
WTS server
Figure 4.3 Direct Serial Connection
A direct connection uses a serial null-modem cable to connect the external computer and the CommServer. This cable appears as a standard modem cable to both the external computer and the CommServer.
Note: The CommServer requires the use of a cable that passes the DTR and
DSR signals. Some cables loop these signals back at the connectors; these cables will not work. Use cable 3002186.
A Modem Connection
web browser, telnet client, or WTS client networking driver serial line networking driver serial line (modem cable 19680)
PSTN
External Computer
modem serial port modem serial port
CommServer
web (HTTP) server telnet server
WTS server
Figure 4.4 Dial-Up Serial Connection
A dial-up connection uses a modem connected to the CommServer’s PPP console port through a standard modem cable. This modem is connected to an incoming phone line, and is configured to automatically answer incoming calls.
Using another modem, administrators at a remote site dial the phone number of the modem line; the modem answers, and connects the incoming call to the
CommServer. The CommServer then sets up a PPP link with the remote site.
Psion Teklogix 9500 Communications Server User Manual
79
Chapter 4: Connecting To The CommServer
Setting Up A Modem Connection
4.6.2 Setting Up A Modem Connection
If the PPP connection uses modems, an external modem must be connected to the
CommServer. Serial port 1 on the hardware version of the CommServer is preconfigured for such a connection, and Psion Teklogix can supply such a modem.
Psion Teklogix provides modems for the CommServer which accept commands from the “Hayes AT” command set. The modem should be set up to auto-answer incoming calls, and its connection to the CommServer should have a bit rate of
57 600 bits per second.
80
Psion Teklogix 9500 Communications Server User Manual
A
DMINISTERING
T
HE
C
OMM
S
ERVER
5
5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
5.2 Managing The 9500 CommServer Software . . . . . . . . . . 83
5.2.1 The Services Screen. . . . . . . . . . . . . . . . . . 83
5.2.2 Starting And Stopping The Service . . . . . . . . . . 85
5.3 SNMP Administration . . . . . . . . . . . . . . . . . . . . . . 87
5.3.1 Setting SNMP Parameters . . . . . . . . . . . . . . 87
5.4 SNA Administration . . . . . . . . . . . . . . . . . . . . . . . 96
5.5 Chassis Monitor Administration . . . . . . . . . . . . . . . . . 97
5.5.1 Starting the Chassis-Monitor Software . . . . . . . . 97
5.5.2 The Temperature Configuration Screen. . . . . . . . 99
5.5.4 The Alerts Configuration Screen . . . . . . . . . . .101
5.5.3 The Power-supply Configuration Screen . . . . . . .100
5.5.5 The Operating-Time Configuration Screen. . . . . .103
5.6 Disk Array Administration. . . . . . . . . . . . . . . . . . . .103
5.6.1 Starting The Disk-Monitoring Software . . . . . . .103
5.6.2 Overall Options . . . . . . . . . . . . . . . . . . . .106
5.6.3 Array Monitoring . . . . . . . . . . . . . . . . . . .110
5.6.4 User Options . . . . . . . . . . . . . . . . . . . . .111
5.7 Viewing Application Log Files . . . . . . . . . . . . . . . . .112
5.8 Network Console Commands . . . . . . . . . . . . . . . . . .114
5.8.1 Selected Configuration Commands. . . . . . . . . .114
5.8.2 Selected Network Console Commands . . . . . . . .115
5.9 Security And Identification . . . . . . . . . . . . . . . . . . .116
Psion Teklogix 9500 Communications Server User Manual
81
Chapter 5: Administering The CommServer
Introduction
5.1 Introduction
Management of the Psion Teklogix CommServer involves a number of tasks. These tasks include:
• Configuration of Windows services.
• Viewing of OS logfiles.
The following additional tasks are applicable to the hardware version of the CommServer:
• Configuration of the chassis-monitoring software.
• Configuration of IBM Personal Communications software, for SNA connectivity.
• Monitoring of the CommServer’s RAID system.
These tasks are available from the CommServer’s OS desktop interface (see
Section 4.3 on page 69 for details on connecting to the desktop interface.) In
addition, the standard features of the operating system are available from the desktop.
Certain tasks may also be available from other interfaces, such as the emulation software’s command-line interface.
5.2 Managing The 9500 CommServer Software
The CommServer software runs as a service under Windows.
5.2.1 The Services Screen
The 9500 CommServer software may be started and stopped from the Services administration screen.
Psion Teklogix 9500 Communications Server User Manual
83
Chapter 5: Administering The CommServer
The Services Screen
To reach the Services screen:
1. Select Start, Settings, Control Panel:
The Windows Control Panel appears:
2. Double-click on the Administrative Tools icon. The Administrative
Tools screen appears:
84
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
Starting And Stopping The Service
3. Double-click on the Services icon. The Services window appears. It lists the available Windows services, and shows the status of each:
5.2.2 Starting And Stopping The Service
The Psion Teklogix Communications Server software may be started and stopped from the Services screen. To do this:
1. Double-click on the service labeled PTX CommServer Watchdog.
This service manages the 9500 CommServer software.
Psion Teklogix 9500 Communications Server User Manual
85
Chapter 5: Administering The CommServer
Starting And Stopping The Service
The Properties window for the service appears:
Depending on the service’s current status, the Start or Stop button will be enabled.
2. Press the Start button to start the service. Press the Stop button to stop the service.
Services may be configured to start automatically when the operating system boots.
To set this:
1. Select Automatic from the Startup Type dropdown list.
2. Press the OK button.
86
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
SNMP Administration
5.3 SNMP Administration
The CommServer’s SNMP functions are handled by the Windows SNMP service.
By default, the Windows SNMP service listens on port 161, which is the standard port assigned for SNMP. In order to avoid port contention with the CommServer’s
Proxy Agent, the CommServer software re-configures the port for Windows'
SNMP service to 11161. This port is restored to 161 if the CommServer’s software is uninstalled.
The Windows SNMP service uses the community name(s) and trap destination(s) that are configured in the SNMP Service Properties dialogue, accessible from the
Services control panel. Configuration changes to these parameters take effect immediately. A restart of the SNMP service is not required.
The CommServer’s SNMP proxy agent obtains and uses the same information from the registry. The 9500 CommServer software must be restarted following a change in community name or trap destination.
5.3.1 Setting SNMP Parameters
To set the CommServer’s SNMP parameters:
1. Select Start, Settings, Control Panel:
Psion Teklogix 9500 Communications Server User Manual
87
Chapter 5: Administering The CommServer
Setting SNMP Parameters
The Windows Control Panel appears:
2. Double-click on the Administrative Tools icon. The Administrative
Tools screen appears:
3. Double-click on the Services icon. The Services window appears. It lists the available Windows services, and shows the status of each:
88
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
Setting SNMP Parameters
In this listing, there are two SNMP services, named ‘SNMP Service’ and ‘SNMP
Trap Service’. The parameters of the SNMP Trap Service need not be changed.
To set up the SNMP Service:
4. Double-click the SNMP Service listing. The SNMP Service Properties
Window appears:
The settings to be adjusted are on the Agent, Traps, and Security tabs.
The Agent Tab
The Agent tab contains settings that identify the CommServer to SNMP managers.
Psion Teklogix 9500 Communications Server User Manual
89
Chapter 5: Administering The CommServer
Setting SNMP Parameters
1. Click on the Agent tab. The Agent settings are displayed:
2. Set the parameters in this tab as follows:
Contact:
The name of the contact person responsible for this device.
Location:
The location of the device.
These two parameters are the SNMP variables system.systemContact and
system.systemLocation respectively. They are accessible to external SNMP agents.
The Service checkboxes specify capabilities that the CommServer has.
This information is provided to SNMP managers. It is best to leave these checkboxes at their defaults.
The CommServer uses the Windows Full computer name parameter for the
SNMP system.systemName parameter. This parameter is configured through the System Properties screen. Select Start, Settings, Control
Panel, System, then the Network Identification tab.
90
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
Setting SNMP Parameters
The Traps Tab
The Traps tab governs outbound SNMP communications; it contains settings that specify where the CommServer will send SNMP trap messages.
3. Click on the Traps tab. The Traps settings are displayed:
On this screen, the administrator can enter the SNMP communities in which this CommServer will participate, and what traps will be sent for each community.
Community name:
This listbox gives the communities to which traps will be sent.
Trap Destinations:
This list specifies the destinations to which traps will be sent in each community. There is a separate list for each community.
To add a community:
4. Type the name of a community in the Community Name box.
Psion Teklogix 9500 Communications Server User Manual
91
Chapter 5: Administering The CommServer
Setting SNMP Parameters
5. Press the Add to List button. The community is added to the list, and the Add button associated with the Trap Destinations listbox becomes active.
To add a trap destination for this community:
6. Press the Add button. A window appears:
7. Enter the host name or IP address for the trap destination.
8. Press the Add button. The window disappears. The new trap destination appears in the Trap Destinations list.
Additional trap destinations can be added in the same way for this community. If another community name is entered into the Community Name box, a different list of trap destinations becomes available. Destinations can be added to this list as well, and the different lists can be selected by choosing the community name from the drop-down list of the Community Name box.
Traps will be sent to all destinations on all lists.
The Security Tab
The Security tab specifies which remote machines are permitted access to the
CommServer’s SNMP services.
92
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
Setting SNMP Parameters
9. Click on the Security tab. The Security settings are displayed:
These settings govern inbound SNMP communication: which nodes on the network will be allowed to communicate with the CommServer’s
SNMP agent.
Send Authentication Trap:
When this parameter is enabled and an SNMP agent is refused connection, the CommServer sends a trap message to all hosts listed in the Traps tab.
Accepted Community Names:
This listbox shows the list of accepted community names. Devices that are members of the listed communities may send SNMP messages to the
CommServer. Devices not in the listed communities will be refused connection.
Each community can have one of the following access rights:
NONE:
A device in this community is not allowed to connect to the CommServer’s
SNMP agent.
Psion Teklogix 9500 Communications Server User Manual
93
Chapter 5: Administering The CommServer
Setting SNMP Parameters
NOTIFY:
A device in this community is not allowed to connect to the CommServer’s
SNMP agent. If the device tries to connect, the CommServer sends a trap message to all trap destinations listed in the Traps tab.
READ ONLY:
A device in this community is allowed to connect to the CommServer’s
SNMP agent, but may only read parameter values from the MIB.
READ WRITE:
A device in this community is allowed to connect to the CommServer’s
SNMP agent, and may read parameter values from and and write them to the MIB.
READ CREATE:
A device in this community is allowed to connect to the CommServer’s
SNMP agent, may read and write parameter values from and to the MIB, and may create new entries in the parameter tables.
To add a community:
10. Press the Add button. The Add Community window appears:
11. Select the desired level of access rights for the new community from the Community rights dropdown box.
12. Type the name of a community in the Community Name box.
13. Press the Add button. The box disappears, and the new community is added to the list. Its settings may be changed through the Edit button, and it may be removed through the Remove button.
94
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
Setting SNMP Parameters
Accept SNMP Packets from any host:
When this radiobutton is enabled, the CommServer accepts SNMP messages from any host. When it is not enabled, the Accept SNMP packets
from these hosts radiobutton below is enabled, and the list of trusted hosts below becomes active. This provides a second level of filtering.
To add a trusted host to the list:
14. Press the Add button. A window appears:
15. Enter the host name or IP address for the trusted host.
16. Press the Add button. The window disappears. The new trusted host appears in the list of trusted hosts.
Additional trusted hosts can be added in the same way.
Note: If a host appears in the Trusted Hosts list, but does not have a community name listed in the Accepted Community Names list, SNMP messages from it will not be accepted. For a trusted host, both host name and community name must match.
The local loopback address (127.0.0.1) must be added as a trusted host, when one or more other trusted hosts are defined. Otherwise, SNMP requests rerouted by the Psion Teklogix SNMP proxy agent will all be rejected by the local SNMP agent.
17. Press OK at the bottom of the dialog box to save the new SNMP settings and close the dialog box. Press Apply to save the new settings without closing the dialog box.
The SNMP settings are now complete for the CommServer.
Psion Teklogix 9500 Communications Server User Manual
95
Chapter 5: Administering The CommServer
SNA Administration
5.4 SNA Administration
This section covers how to start the SNA node-configuration utility, which is included in the hardware version of the CommServer. This utility is part of IBM’s
Personal Communications suite of software. Specific configuration details for 5250 and 3274 are covered in
Chapter 8: Set-Up For 3274 Emulation
and
To start the IBM Personal Communications node-configuration software:
1. Open the CommServer’s desktop interface.
2. Double-click on the SNA Node Configuration icon
(illustrated at right).
The SNA Configuration dialog box appears:
This box has a list of configuration options, and a section below where the configuration of the selected option can be changed or modified.
Note: Help for SNA configuration is available by selecting Help, Using Node
Configuration.
96
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
Chassis Monitor Administration
5.5 Chassis Monitor Administration
Software in some versions of the CommServer can monitor chassis temperature, cooling-fan speed, and chassis voltages. A circuit-board inside these versions of the
CommServer is connected to sensors that measure temperature and system voltages.
5.5.1 Starting the Chassis-Monitor Software
To start this software:
1. Open the CommServer’s desktop interface.
2. Do one of the following:
• Double-click on the Chassis Monitor icon
(illustrated at right).
• Select Start, Programs, Chassis Monitor.
The main screen of the chassis monitor software opens:
This main screen displays the following items:
• A row of temperature indications.
• A row of voltage indications.
• A group of status indicators.
• A group of buttons.
Psion Teklogix 9500 Communications Server User Manual
97
Chapter 5: Administering The CommServer
Starting the Chassis-Monitor Software
These are described below.
Temperature Indicators
Temperatures are reported by sensors located inside the chassis, near the air intake and near the processor. On the main screen, the indicated temperature scale is selectable as either Fahrenheit or Celsius. This selection is reflected in the other screens of the monitoring software.
The Voltage Indicators
System voltages are reported by sensors on the main voltage supplies of the
CommServer hardware. There are indicators for the voltage on the +3.3 V, +5 V,
+12 V, -5 V, and -12 V supplies.
The Status Indicators
There are three status indicators, for System Status, Power-supply Status, and
System Operating Time.
The System Status indicator shows an overview of the system, including any faults that have occurred and alerts that have been sent.
The Power-supply Status indicator shows the state of the power-supply.
The System Operating Time indicator shows the amount of power-on time that has elapsed since the system was put into service, or the timer was reset.
The Buttons
The buttons at the bottom of the screen are as follows:
Configure Temperatures
When pressed, this button opens the Temperature Configuration Screen.
See “The Temperature Configuration Screen” on page 99 for details.
Configure Alerts
When pressed, this button opens the Alerts Configuration Screen. See “The
Alerts Configuration Screen” on page 101 for details.
Configure Power Supplies
When pressed, this button opens the Power-supply Configuration Screen.
See “The Power-supply Configuration Screen” on page 100 for details.
98
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
The Temperature Configuration Screen
Configure Operating Time
When pressed, this button opens the Operating-time Configuration Screen.
See “The Operating-Time Configuration Screen” on page 103 for details.
Press the Exit Program button to end the program.
5.5.2 The Temperature Configuration Screen
In this screen, a maximum temperature setting can be configured for each of the temperature sensors. If the temperature reported by the sensor exceeds this maximum, the monitoring software displays an indication on the main screen and sends an alarm message to the recipients whose email addresses are configured in the Alerts Configuration Screen.
Note: The maximum-temperature values in this screen are displayed in
Fahrenheit or Celsius degrees, according to the measurement unit selected on the Main Screen.
Press the Default Values button to reset the limits to their defaults.
Press the OK button to save the changes and return to the main screen.
Press the Cancel button to abandon the changes and return to the main screen.
Psion Teklogix 9500 Communications Server User Manual
99
Chapter 5: Administering The CommServer
The Power-supply Configuration Screen
5.5.3 The Power-supply Configuration Screen
In this screen, maximum and minimum voltage settings can be configured for each of the five standard voltages (+3.3 V, +5 V, +12 V, -5 V, and -12 V) supplied by the
CommServer’s power-supply unit.
If the voltage reported by a sensor exceeds the specified range, the monitoring software displays an indication on the main screen and sends an alarm message to the recipients whose email addresses are configured in the Alerts Configuration
Screen.
A delay can be specified as well. Short fluctuations in voltage that exceed the specified range, but end before the delay period ends, will not cause alerts to be issued by the software.
In addition, this screen contains parameters for power-supply lifetime monitoring.
Each power-supply module is given a ‘Mean Time Before Failure’ (MTBF) rating, expressed as a number of hours. When the module is installed, the ‘install time’ is set to zero, and the software counts the number of hours it is in use. When the number of hours elapsed equals the MTBF rating, the module should be replaced.
100
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
The Alerts Configuration Screen
To set the parameters for a new module:
1. Press the Set Install Time to Current Time button for the desired module.
2. Enter the module’s MTBF rating in the Module MTBF Rating textbox.
The software starts to count the number of hours that the module is in service. If the
Send Email If MTBF Expires parameter on the Alerts Configuration Screen is checked, the software sends an alert message to the recipients whose email addresses are configured in the Alerts Configuration Screen.
Press the OK button to save the changes and return to the main screen.
Press the Cancel button to abandon the changes and return to the main screen.
5.5.4 The Alerts Configuration Screen
The parameters in this screen govern when and where the chassis monitor sends alert messages. Alert messages can be sent as email whenever the chassis monitor detects a fault.
The first three parameters specify an SMTP server for the email:
Psion Teklogix 9500 Communications Server User Manual
101
Chapter 5: Administering The CommServer
The Alerts Configuration Screen
Email server SMTP:
The IP or domain name for the mail server that will handle outgoing alert messages.
Local email address:
The address from which the alert messages are being sent.
Local System Name:
The name of the system. It will be included in the email message as the source of the alert.
The next five parameters are email addresses of the recipients of the alert messages.
Not all of them need be configured.
Send email if alert occurs:
Send an alert message to all email recipients if the chassis monitor issues an alert.
Send email if MTBF expires:
Send an alert message to all email recipients if the Mean Time Before
Failure of a monitored power-supply module has expired.
Resend email every...:
Resend the alert message to all email recipients at intervals specified by the associated radiobuttons and textbox. Intervals may be specified as minutes, hours, or days.
Log email activity:
Make a record of the email sent. The log file is saved in the directory
C:\Program Files\Psion Teklogix\Chassis
.
Press the OK button to save the changes and return to the main screen.
Press the Cancel button to abandon the changes and return to the main screen.
102
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
The Operating-Time Configuration Screen
5.5.5 The Operating-Time Configuration Screen
This screen displays the cumulative elapsed time that the CommServer system has been running. This time can be reset to zero.
5.6 Disk Array Administration
Some CommServers are fitted with a RAID hard-disk array set up for ‘mirroring’.
These units have software that allows the administrator to monitor the disk array.
5.6.1 Starting The Disk-Monitoring Software
To start the disk-monitoring software:
1. Open the Windows desktop interface.
2. Perform one of the following:
• Double-click on the Local Monitoring icon on the Windows desktop.
• Select Start, Programs, Promise Array
Management, Local Monitoring Utility.
Psion Teklogix 9500 Communications Server User Manual
103
Chapter 5: Administering The CommServer
Starting The Disk-Monitoring Software
3. The window of the disk-monitoring software appears:
The window of the disk-array-monitoring software has three panes:
At the left, a tree pane can display a branching tree of the different screens of the software.
At the top right, icons appear as shortcuts to sub-items in the tree.
The largest part of the window, at bottom right, monitors the disk array and displays its parameters.
Note: Detailed help for the disk-monitoring software is available by selecting
Help, Help Topics.
To use the software, the administrator must ‘log in’ to it. To do this:
1. Select the LOCALAGENT item in the tree at the left-hand side of the window.
104
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
Starting The Disk-Monitoring Software
2. Do one of the following:
• Select RAIDmachine, Login.
• Right-click the LOCALSERVER item in the tree. A pop-up menu appears. Select Login from this menu.
A dialog box appears:
3. Enter the correct name and password to gain access to the software.
Note: The default values are username ‘Administrator’ and an empty password.
When the username and password are accepted, the name of the
LOCALSERVER item changes to the name that has been assigned to this CommServer. (This tree item will subsequently be referred to as
CommServer Name.)
The tree structure on the left can then be expanded to appear as follows:
Psion Teklogix 9500 Communications Server User Manual
105
Chapter 5: Administering The CommServer
Overall Options
The tree structure contains options:
• For the disk-monitoring software as a whole.
Select the CommServer Name tree entry. See Section 5.6.2 on page 106.
• For monitoring the disk array.
Select the FASTTRAK tree entry. See Section 5.6.3 on page 110.
• For setting passwords and authorizing additional users.
Select the Users tree entry. See Section 5.6.4 on page 111.
5.6.2 Overall Options
When the CommServer Name item in the tree is selected, the overall options for the disk-array-monitoring software are available in the largest pane of the window.
They can be made visible by scrolling the pane.
When options are changed in these screens, a Change button becomes active. Press this button to commit the changes to the software.
These options include the following.
Logging and email server parameters:
106
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
Overall Options
Enable NT System logging
Select this parameter to have the disk-monitoring software log events in a system log. This log is readable through the Windows Application Log
Viewer (see “Viewing Application Log Files” on page 112).
Email Alert on Error
Select this parameter to cause the disk-monitoring software to send an alert message to all configured recipients when an error occurs.
SMTP Server
Enter the IP address or resolveable domain name of an SMTP server that will handle the alert messages.
Note: If you are using the CommServer’s internal SMTP server, set this address to the local loopback address 127.0.0.1. This requires that the loopback address be in the CommServer’s host table, and that the Windows SMTP server be configured and running.
Authentication method
Select an authentication method for logging into the SMTP server here. If no authentication method is selected, the username and password will be greyed out.
The next section includes email sender and recipient parameters:
Email ID of Alert Sender
The email address of the CommServer. This address is used in the ‘From’ field of the email that the disk-monitoring software sends.
To enter a name, type the name and address into the text field and then press the Change button.
Psion Teklogix 9500 Communications Server User Manual
107
Chapter 5: Administering The CommServer
Overall Options
Alert Recipients... List
This list contains the email address of the recipients. Alerts will be sent to all recipients.
To enter a name, type the name and address into the text field and then press the Add button. The address will appear in the listbox below:
Addresses in this listbox can be selected. Selected addresses can be removed by pressing the Remove button.
The next part of the parameters screen allows the administrator to select the events for which the disk-monitoring software will send an email alert:
Each alert has a yes/no choice for sending an email announcement when an alert happens, and a yes/no choice for creating an popup announcement window on the desktop when an alert happens. These choices are all selected to be No by default.
To change the state of one of these choices:
108
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
Overall Options
1. Double-click the word Yes or No next to the parameter name. A menu appears.
2. Select Yes or No as desired. The choice changes in the list window.
3. Press the Change button to apply the changes.
Checkboxes are available to select Yes (to enable) the email alerts for all of these parameters, and the popups for all of these parameters.
Important: Do NOT enable popup notification if the CommServer is intended to run unattended.
The last group of main screen parameters govern scheduling of synchronization of the disks in the disk array:
By default these options are disabled; synchronisation takes place at need.
Psion Teklogix 9500 Communications Server User Manual
109
Chapter 5: Administering The CommServer
Array Monitoring
5.6.3 Array Monitoring
When the FASTTRAK item in the tree is selected, the array monitor software displays a number of options relating to the disk array:
Some overall options for the disk array itself are available in the largest pane of the window. They can be made visible by scrolling the pane.
This screen has parameters governing the rebuilding of the disk array.
110
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
User Options
Status information about the disk array and the disk enclosures can be viewed by clicking one of the items in the tree below the FASTTRAK item.
To view the status of the hard drives in the array, click the Enclosure item in the tree.
The largest pane of the window changes to give a status display for the drives:
The status information display includes voltages to the drives, drive temperature, and drive fan speed.
5.6.4 User Options
When the Users item in the tree is selected, the array monitor software displays a number of options relating to users:
Psion Teklogix 9500 Communications Server User Manual
111
Chapter 5: Administering The CommServer
Viewing Application Log Files
A password may be specified for the array administrator here. The default is to have no password.
5.7 Viewing Application Log Files
The CommServer software generates application logs that can be viewed from the
Windows Event Viewer. The following events are logged:
• The ‘watchdog’ task is started.
• The watchdog restarts another task from crash or exit, or from checkpoint failure or timeout.
• The user manually starts, terminates, or restarts a process (through the watchdog).
• There is a change of redundancy status for the CommServer: secondary to primary, or vice versa.
• The CommServer starts up as primary, or secondary.
To view the logfiles:
1. Open the CommServer’s desktop. See Section 4.3 on page 69 for
details on connecting to the CommServer’s desktop.
2. Select Start, Settings, Control Panel:
112
Psion Teklogix 9500 Communications Server User Manual
The Windows Control Panel appears:
Chapter 5: Administering The CommServer
Viewing Application Log Files
3. Double-click on the Administrative Tools icon. The Administrative
Tools screen appears:
4. Double-click on the Windows Event Viewer icon. The Event Viewer window opens.
5. Select the Application Log to view Psion Teklogix Communications
Server entries. The entries of that log appear at the right. Individual entries may be opened by double-clicking on them.
Psion Teklogix 9500 Communications Server User Manual
113
Chapter 5: Administering The CommServer
Network Console Commands
5.8 Network Console Commands
The Psion Teklogix Communications Server has a text-mode interface, the ‘network console’, at which a number of commands can be issued.
Once the user has connected, the network console appears as follows:
New Telnet Console Client Attached.
>
The console prompt is a “right angle bracket” character, “>”, set one character in from the left-hand side of the console display.
Note: If the prompt does not appear, press <ENTER>. In response, the
CommServer should provide a prompt. If it does not, there may be a communications problem.
Many tasks print characters to the console. They place their single-character ID to the left of the “>” character as a method of identifying the source of their output.
The console commands on the CommServer are similar in form to those of Psion
Teklogix’ Model 9300 and 9400 network controllers. Specific commands may differ from their equivalents on these machines.
5.8.1 Selected Configuration Commands
The CommServer’s console interface can be used as a command line interface to the configuration database; it perform many of the same tasks as the CommServer’s web configuration interface.
Selected configuration commands appear as follows:
c get <key>
retrieve a key value from the database
c put <key> <value>
change the value for a key in the database
c read <filename>
read the configuration from a file
c write <filename>
write the configuration to a file
114
Psion Teklogix 9500 Communications Server User Manual
Chapter 5: Administering The CommServer
Selected Network Console Commands
c commit
save current configuration
c rollback
restore CommServer’s settings from saved configuration
Notes:
1. Possible key types are
ASCII
,
binary
,
bool
,
int
,
uint
,
IP
,
MAC
,
enum
, and
vlist
.
2. All keys are of the form
x.y.z
. For example:
drivers.0.enabled
,
protocols.tcpip.name
.
3. Values must be of the correct form. Boolean values are
True
and
False
.
4. IP addresses are of the form
www.xxx.yyy.zzz
. For example:
10.128.0.33
.
5. MAC addresses are of the form
aa:bb:cc:dd:ee:ff
, where the values are all colon-separated and all hexadecimal.
6. Binary values are also entered in hexadecimal.
7. File names should be in valid Windows 2000 format (up to eight characters, plus optionally a period and an extension of up to three characters).
This is the same as the older 8.3 DOS format.
5.8.2 Selected Network Console Commands
The network console provides an interface between the user and the tasks which are running in the CommServer’s Psion Teklogix software. Client tasks (emulations, etc.) connect to it, and send it data to be printed. Data entered on the command line is routed by the console program to the correct task.
Selected console commands appear as follows from the console:
help [keys]
prints a help message for the
nconsole
task. The command
help keys
provides help on keystrokes available for command-line editing.
ver
prints version information for the network console.
Psion Teklogix 9500 Communications Server User Manual
115
Chapter 5: Administering The CommServer
Security And Identification
5.9 Security And Identification
The CommServer uses the Windows operating system and security.
The hardware CommServer has computer name PSION-xxx, where xxx denotes a unique ID generated when the operating system is installed. The computer workgroup is PTXCOMMSERVER.
Important: Psion Teklogix recommends that this computer name be changed after installation.
The hardware CommServer comes with several pre-configured user accounts. The root or administrator account has the user name of PTX_Admin, a null password, and belongs to the Admin group.
Important: Psion Teklogix recommends that this password be changed after installation.
There is also a user account for Psion Teklogix support personnel, with user name
support and group Admin.
116
Psion Teklogix 9500 Communications Server User Manual
S
ET
-U
P
F
OR
ANSI E
MULATION
6.1 Types Of Connections . . . . . . . . . . . . . . . . . . . . . .119
6.2 ANSI (Over Ethernet) . . . . . . . . . . . . . . . . . . . . . .120
6.2.1 Physical Connection . . . . . . . . . . . . . . . . .120
6.2.2 Host Configuration: ANSI-TCP/IP . . . . . . . . . .120
6.2.3 CommServer Configuration: ANSI-TCP/IP . . . . .120
6
Psion Teklogix 9500 Communications Server User Manual
117
Chapter 6: Set-Up For ANSI Emulation
Types Of Connections
6.1 Types Of Connections
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
ANSI
TESS
PTX
Handler Software
PTX
Emulation
Software
9500 CommServer
Base
ANSI
Terminal
Software
TESS
Web
Browser
HTTP
Terminal
HTTP Server
Host Computer
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
ANSI
TESS
PTX
Handler Software
PTX
Emulation
Software
9500 CommServer
Base
ANSI
Terminal
Software
TESS
HTTP
Web
Browser
Terminal
HTTP Server
Host Computer
Figure 6.1 ANSI Datastreams In The Psion Teklogix System
The Psion Teklogix Communications Server manages the radio link, caches data going to and from the terminals, and supervises the handoff of terminals as they move from one base to another.
The following connection is possible between the CommServer and the ANSI host:
• ANSI via TCP/IP over Ethernet.
Psion Teklogix 9500 Communications Server User Manual
119
Chapter 6: Set-Up For ANSI Emulation
ANSI (Over Ethernet)
6.2 ANSI (Over Ethernet)
6.2.1 Physical Connection
The following diagram shows typical connections and cabling:
TCP/IP over Ethernet
10Base-T
100Base-T host
9500
CommServer
10Base-T
100Base-T
Ethernet Network
TCP/IP TCP/IP
Figure 6.2 Ethernet Connections
Ethernet connections run at a speed of 10 or 100 megabits per second. Ethernet networks running at 10 Mb/s use cable types 10Base-T, 10Base5 and 10Base2, which use RJ45, DC-15 and BNC connectors, respectively. Ethernet networks running at 100 Mb/s use 100Base-T cables, which also use RJ45 connectors.
The Communications Server’s onboard Ethernet connection supports 10Base-T and
100Base-T Ethernet.
6.2.2 Host Configuration: ANSI-TCP/IP
The host should be configured to work with ANSI, VT-100, or VT-220 terminals.
Many systems can negotiate their terminal type when using the telnet protocol.
6.2.3 CommServer Configuration: ANSI-TCP/IP
Important: Changes to the CommServer’s configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
6.2.3.1
Setting Up The Network Adaptor
The hardware version of the CommServer can have up to two Ethernet network connections. Each network connection is set up from Windows network configuration.
120
Psion Teklogix 9500 Communications Server User Manual
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
Note: Adaptor cards for the hardware CommServer, such as the Ethernet card, are normally installed by Psion Teklogix at the factory when the unit is manufactured. They can also be installed at an authorized service centre.
A network card must be configured if you are installing the Psion Teklogix
CommServer software on your own hardware. You will need the make and model number of the Ethernet card, and the driver for the card.
To configure a network card:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Add New Hardware. The Add New Hardware wizard appears.
4. Follow the steps to add the new Ethernet interface.
6.2.3.2
Specifying The CommServer’s TCP/IP Settings
TCP/IP parameters are configured through the CommServer’s Windows networking interface.
To set up the IP parameters of the network interface:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Network and Dial-Up Connections. The Network and Dial-Up
Connections window appears, with a LAN connection for the new interface.
4. Right-click on the LAN connection. A pop-up menu appears.
5. Select Properties. A Properties dialogue appears listing the network interface and the protocols it supports; the network interface is named at the top of this window.
6. Select the TCP/IP protocol from the list.
7. Press the Properties button. The IP Properties dialogue appears.
Psion Teklogix 9500 Communications Server User Manual
121
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
8. Set the parameters as follows:
Obtain an IP address automatically: Unselect this radiobutton. The three parameters below this radiobutton become available:
IP address: Enter the IP address of the CommServer’s network adaptor.
Subnet mask: Enter a network mask for this interface.
Default gateway: Enter the IP address of the default gateway. Packets not destined for the local subnet will be sent to this address unless there are other options.
Obtain DNS server address automatically: Select this radiobutton.
9. Press the OK button. The IP Properties dialogue closes.
10. Press the OK button. The Local Area Connection Properties dialogue appears.
6.2.3.3
Setting Up The CommServer’s Host Table
The host table resolves IP adresses from host names. If DNS is not being used, and a static host table is desired for the CommServer, the Windows host table can be modified to include the desired host entries. The host table file is located in the directory:
C:\WINNT\system32\drivers\etc and its name is simply hosts
(with no filename extension). Entries in the
Windows host table take preference over those provided by software such as DNS.
Note: The term host in this context refers to any device with an IP address,
including parts of the Psion Teklogix system such as the CommServer and its associated base stations.
This use of host is common in the networking field. It should be
distinguished from Psion Teklogix’s use of host versus terminal.
To manually add an entry to the CommServer’s host table:
11. Open the host table file in a text editor.
122
Psion Teklogix 9500 Communications Server User Manual
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
Entries in the host table appears as follows:
127.0.0.1 localhost
12. Add another line with the hostname of the host, and its IP address.
6.2.3.4
Setting Up The CommServer’s Routing Table
The routing table is used when the CommServer and the host are not configured to communicate on the same IP subnet.
To add an entry to the CommServer’s routing table:
1. Select Start, Settings, Control Panel. The Control Panel opens.
2. Select Administrative Tools. The Administrative Tools icons appear.
3. Select Routing and Remote Access. The Routing and Remote Access window opens. This window has a tree at the left-hand side.
Note: Help for the Routing and Remote Access window is available by selecting
Action, Help, or by pressing the Help icon.
4. Click on the name of the CommServer. The tree expands to show the choices for the CommServer.
5. Click on IP Routing. The tree expands to show the choices for the
CommServer’s IP routing.
6. Click on Static Routes. A list appears at right; any hosts already in the routing table will be listed here.
7. Right-click on the list. A pop-up menu appears.
8. Select New Static Route... from the menu. The New Static Route dialog box appears.
9. Set these parameters as follows:
Interface: select Local Area Connection.
Destination: Enter the IP address of the host.
Psion Teklogix 9500 Communications Server User Manual
123
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
If the host is on the same subnet as the CommServer, enter its address here and in the Gateway textbox.
Subnet Mask: Set this parameter according to the destination IP address.
Gateway: Enter the router’s IP address in this textbox. This device must be on the same subnet as the CommServer, and must be capable of sending packets to the host. If the host is on the same subnet as the CommServer, enter its address here and in the Destination textbox.
Note: The IP addresses on this screen must be entered as four decimal numbers
(from 000 to 255 inclusive). The dialog box automatically skips past the dots.
Metric Count: Leave this parameter at 1.
10. Press the OK button. The new route appears in the list.
Close the Routing and Remote Access dialog box.
6.2.3.5
Setting Up The Host Connection
On the main configuration screen, a new host can be defined, or an existing host selected, from the Hosts listbox. Pressing the Configure button next to the Hosts listbox opens the Configure New Host screen for new hosts, or the Host Menu screen for existing hosts.
124
Psion Teklogix 9500 Communications Server User Manual
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
Follow these steps to set up a new host connection as host number one in this
CommServer:
1. Select Create New in the Hosts listbox
2. Press the Configure button. The CommServer displays the Configure
New Host screen.
The Configure New Host Screen
General properties of the new host connection are set here in the Configure
New Host screen.
3. Set these parameters as follows:
Host Name: Enter a name for the new ANSI host in this textbox.
Enabled: Place a check mark in this checkbox. The new ANSI host will be enabled and active.
Emulation and Protocol: Choose an emulation and protocol combination for this host from this drop-down listbox. Only certain combinations of emulation and protocol are available. Select the ANSI/Telnet combination.
Terminal Range: This pair of parameters has two text boxes. In the left box, enter the lowest terminal number which will be assigned to this host, and in the right box enter the highest terminal number which will be assigned to this host.
Psion Teklogix 9500 Communications Server User Manual
125
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
4. Press the OK button. The CommServer displays a screen confirming that changes have been made.
5. Press OK on this screen. The CommServer displays the
Configuration Main Menu. The Hosts listbox now has an entry for the newly-defined host.
6. Select the new host from the Hosts listbox.
7. Press the Configure button. The CommServer displays the Host Menu:
The Host Menu
Each item on the Host Menu has an associated button.
The button associated with General Options, the first item on the Host
Menu, displays the General Host Options screen. This screen has the same options as the New Host screen, except that there is also a Delete button which removes the host connection from the CommServer’s configuration.
No options need be changed on the General Host Options screen.
8. Press the Configure button associated with Emulation Options. The
CommServer displays the ANSI Emulation Options screen shown on
126
Psion Teklogix 9500 Communications Server User Manual
The ANSI Emulation Options Screen
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
Set the parameters on this screen as follows:
Maximum Screen Size: These textboxes allow the user to specify the dimensions, in rows and columns, of the maximum terminal screen size.
Host Timeout (used in page-saving mode only): This textbox indicates the length of time (in ticks, or sixtieths of a second) that the CommServer will wait for additional data before assuming that host has finished sending data.
Leave this parameter at its default of 20 ticks.
Escape Timeout (used in page-saving mode only): This text box indicates the length of time (in ticks) that the CommServer will wait after receiving an ‘escape’ character before assuming that following characters are not part of an escape sequence.
Leave this parameter at its default of 12 ticks.
Psion Teklogix 9500 Communications Server User Manual
127
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
Threshold (used in page-saving mode only): This text box indicates the number of bytes by which a page update or new incoming page is different than previously-stored pages, in order for the CommServer to recognize it as a new page, and store it separately.
Leave this parameter at its default of 200 bytes.
Echo: This checkbox enables smart echo for this host. When using echo,
ANSI hosts will return a character to the terminal whenever the terminal sends a character. The host echoes input data back to the terminals. When smart echo is enabled, the CommServer will not return host echoes to the terminals if they match the original characters sent from the terminals. This reduces the amount of data sent over the radio link.
Leave this parameter at its default (enabled).
Function-Key Remapping: Leave this parameter at its default (disabled).
Page: This checkbox enables page-saving mode for this host. In pagesaving mode, both the CommServer and the terminal maintain identical caches of screen images, or pages, containing screen data sent from the host. The CommServer compares new pages sent to it from the host with those in its cache, and, if it finds a match, instructs the terminal to use the corresponding page from its cache rather than wait for the CommServer to send it. This reduces the amount of data sent over the radio link.
When page-saving mode is enabled, the Threshold, Escape Timeout, and
Host Timeout parameters become active; otherwise, they are ignored.
Leave this parameter at its default (enabled).
Page Saving consider Double Byte Characters: While using double byte character sets (for example, Chinese or Korean), the Page Saving function can cause a double byte character to be partially overwritten. This can cause unprintable screen data and unintended characters; and may cause the terminal to shift data on the screen. Selecting this checkbox causes a double byte character half to be replaced with a space, preventing problems with terminal screen displays. This checkbox should only be selected when using double byte character sets.
128
Psion Teklogix 9500 Communications Server User Manual
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
RLE: This checkbox enables run-length encoding of the ANSI datastream.
Under run-length encoding, if there is a long sequence of identical characters in the ANSI datastream, the CommServer will replace the sequence with a single character of the same type and an escape sequence indicating the number of characters. This can dramatically reduce the number of bytes sent over the radio link.
Leave this parameter at its default (enabled).
Convert 7 to 8 Bit: This checkbox enables 7-to-8-bit conversion of escape codes in the ANSI datastream. When enabled, the conversion causes compression of the escape codes.
Leave this parameter at its default, unchecked.
The ANSI parameters are now set up. The next step is to set up the telnet parameters.
9. Press the OK button at the bottom of the ANSI parameter screen. The
CommServer displays the Host Menu.
10. Press the Configure button associated with Protocol Options. The
CommServer displays the Protocol Options screen (see page 130):
Psion Teklogix 9500 Communications Server User Manual
129
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
The ANSI Telnet Protocol Options Screen
11. Set the parameters on this screen as follows:
Terminal Type: This listbox contains the type of terminal which the
CommServer will emulate. Two types are available, the VT-100, and the
VT-220. Select VT-220.
130
Psion Teklogix 9500 Communications Server User Manual
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
Host Port: This textbox contains the port number on the host to which the
CommServer directs telnet connection-requests. Leave this parameter at its default of 23.
Maximum Sessions Per Terminal: This text box indicates the maximum number of ANSI telnet sessions which will be allowed to originate from each terminal. Leave this parameter at its default of 4.
Close Host Sessions on Terminal Reset: If this checkbox is selected, all host sessions will be closed when the terminal resets. If the checkbox is unselected, the sessions will remain open if the terminal resets.
First Local Terminal Port: This textbox specifies the port number from which the CommServer attempts a telnet connection for the first terminal.
Additional telnet sessions are assigned higher port numbers. Set this parameter to 16100.
Local IP Address To Bind: Enter the IP address of the CommServer on the
Ethernet network in this textbox.
First Terminal Listen Port: This textbox specifies the lowest port number at which the CommServer listens for telnet connections initiated by the host. Leave this parameter at its default of 10000.
TCP Session Request Key: This textbox contains the decimal ASCII character code of the character which will prompt the terminal to request a new
ANSI terminal session. Leave this parameter at its default of 1.
Session Cycle Key: This textbox contains the decimal ASCII character code of the character which will prompt the terminal to display the next
ANSI terminal session. Leave this parameter at its default of 2.
Last Active Session Key: This textbox contains the decimal ASCII character code of the character which will prompt the terminal to display the last
ANSI terminal session.
Leave this parameter at its default of 5.
Auto-Telnet/Auto-Login Enable Listbox: This listbox enables the user to disable or enable automatic connection of telnet sessions from terminals to this host.
Psion Teklogix 9500 Communications Server User Manual
131
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
The choices provided are disable auto-telnet, enable auto-telnet, and
enable auto-telnet and auto-login. Leave this listbox at its default of
disable auto-telnet.
When auto-telnet is disabled, telnet sessions from the terminals to the host must be initiated manually from the terminals. The remaining parameters on the page (Auto-Telnet Host, Auto-Telnet Terminal Prompt, Auto-
Login User ID, Auto-Login Password, Auto-Login User ID Prompt,
Auto-Login Password Prompt, Auto-Login Failed Login) are not used.
Allow TCP Sessions: If this checkbox is unselected, all requested sessions will be Auto-Login sessions. If the checkbox is selected, the sessions will be either Auto-Login or TCP sessions.
The Telnet protocol parameters are now set up. Next, the function-key parameters can be set up.
12. Press the OK button at the bottom of the Protocol Options screen. The
CommServer displays the Host Menu.
13. Press the Configure button associated with Function Key Mappings.
The CommServer displays the ANSI Function Key Mappings screen:
132
Psion Teklogix 9500 Communications Server User Manual
The ANSI Function Key Mappings Screen
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
Each ANSI function key is associated with a sequence of bytes.
The terminal sends that sequence of bytes to the host when the function key is pressed.
Psion Teklogix 9500 Communications Server User Manual
133
Chapter 6: Set-Up For ANSI Emulation
CommServer Configuration: ANSI-TCP/IP
This screen displays these sequences for each key. The default sequences are the standard ANSI control sequences for each function key.
Leave these parameters at their defaults.
14. Press the OK button at the bottom of the ANSI Function Key Mappings screen. The CommServer displays the Host Menu.
The CommServer is now configured for an ANSI connection to the host.
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the CommServer’s emulation software. See page C-181 in Appendix C,
“The 9500 CommServer’s Web Interface”.
134
Psion Teklogix 9500 Communications Server User Manual
S
ET
-U
P
F
OR
2392 E
MULATION
7
7.1 Types of Connections . . . . . . . . . . . . . . . . . . . . . .137
7.2 2392-TCP/IP (Over Ethernet) . . . . . . . . . . . . . . . . . .138
7.2.1 Physical Connection . . . . . . . . . . . . . . . . .138
7.2.2 DTC Configuration: 2392-TCP/IP . . . . . . . . . .138
7.2.3 CommServer Configuration: 2392-TCP/IP. . . . . .140
Psion Teklogix 9500 Communications Server User Manual
135
Chapter 7: Set-Up For 2392 Emulation
Types of Connections
7.1 Types of Connections
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
ANSI
PTX
Handler
TESS
HTTP Server
Host Computer
PTX
Emulation
Software
9500 CommServer
Base
ANSI
Terminal
Software
TESS
HTTP
Web
Browser
Terminal
Figure 7.1 2392 Datastreams In The Psion Teklogix System
Psion Teklogix RF terminals emulate HP2392A display terminals – asynchronous terminals capable of character, line and block mode. These terminals also handle
ANSI terminal commands.
Several types of connection options to the HP3000 are possible. The CommServer handles only Ethernet connections to an HP DTC with a network interface card.
Psion Teklogix 9500 Communications Server User Manual
137
Chapter 7: Set-Up For 2392 Emulation
2392-TCP/IP (Over Ethernet)
7.2 2392-TCP/IP (Over Ethernet)
7.2.1 Physical Connection
The following diagrams show typical connections and cabling:
TCP/IP over Ethernet
HP3000
10-BaseT
100-BaseT
TCP/IP
Ethernet Network
TCP/IP
10-BaseT
100-BaseT
9500
CommServer
Figure 7.2 TCP/IP Connections
Ethernet connections run at a speed of 10 or 100 megabits per second. Ethernet networks running at 10 Mb/s use cable types 10Base-T, 10Base5 and 10Base2, which use RJ45, DC-15 and BNC connectors, respectively. Ethernet networks running at 100 Mb/s use 100Base-T cables, which also use RJ45 connectors.
The Communications Server’s onboard Ethernet connection supports 10Base-T and
100Base-T Ethernet.
7.2.2 DTC Configuration: 2392-TCP/IP
The following is an example of a DTC configuration for a TCP/IP connection.
The more important definitions (in relation to the Psion Teklogix system) are highlighted.
Important: This section assumes that you are familiar with NMMGR on an HP/XL and have a working knowledge of HP Openview
DTC Manager.
THE DTC SETUP SHOULD BE PERFORMED BY
QUALIFIED PERSONNEL, WHO ARE FAMILIAR WITH
ITS CONFIGURATION!
138
Psion Teklogix 9500 Communications Server User Manual
Chapter 7: Set-Up For 2392 Emulation
DTC Configuration: 2392-TCP/IP
NMMGR/3000 (B.04.07) #1 Open Configuration/Directory File
Enter a file or directory name and press the corresponding function key.
Command:
Configuration file name
Backup Configuration file name
Network directory file name
[NMCONFIG.PUB.SYS
[NMCBACK.PUB.SYS
[NSDIR.NET.SYS
If a write access password has been assigned, you must enter the password to modify the configuration file.
Write access password
[ ]
]
]
]
NMMGR/3000 (B.04.07) #34 Host Configuration
Fill in the required information; then press the Save Data key.
Command:
Local HP 3000 node name
node.network.customer
Link name
[DTSLINK
Physical path of LANIC
If non-nailed PAD connections:
]
[56
Number of non-nailed PAD terminals
Non-nailed PAD terminal profile name
]
HP3000 node name
[RFTERM
[
16 RF terminals
16]
]
File: NMCONFIG.PUB.SYS
Psion Teklogix 9500 Communications Server User Manual
139
Chapter 7: Set-Up For 2392 Emulation
CommServer Configuration: 2392-TCP/IP
NMMGR/3000 (B.04.07) #35 DTC48 Configuration
Fill in the required information; then press the Save Data key.
Command:
To see another DTC, enter the name and press Read DTC
DTC name:
[DTC04 ]
DTC LAN station address:
DTC with Ethernet card
Node name of DTC
DTC node name:
[node.domain.organization
(node.domain.organization)
[08-00-09-04-41-9E]
(in hex)
]
0
1
2
3
4
DTC IP Address:
[50.20.141.18
]
(optional)
Enter card types as installed in DTC:
Card # Type
IP address of DTC
Enable logging class <Y/N)
1
[Y]
4
[N]
2
5
[Y]
[N]
[D]
[D]
[D]
[D]
[D]
(D = Direct connect
M = Modem
X = X.25)
If configuring X.25/PAD: (optional)
PAD access password
[
5
[X]
To configure a card, enter a card number and then press Config Card.
File: NMCONFIG.PUB.SYS
3
[Y]
6
[N]
]
[0 ]
7.2.3 CommServer Configuration: 2392-TCP/IP
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the CommServer’s emulation software. See page C-181 in Appendix C,
“The 9500 CommServer’s Web Interface”.
The following is a sample configuration of the CommServer configuration for
2392/Telnet over an Ethernet line to a web server (an HTTP host).
Only the relevant parameters in each screen are described here. For a complete definition of all the elements in each screen, please refer to Appendix C, “The 9500
CommServer’s Web Interface”.
140
Psion Teklogix 9500 Communications Server User Manual
Chapter 7: Set-Up For 2392 Emulation
Setting Up The Network Connection
The configuration process on the CommServer has a number of steps:
• Configuring the network interface.
• Configuring the CommServer’s IP settings, including the host and routing tables.
• Configuring the host connection, including emulation options, protocol options, and function keys.
These steps are described in the following sections.
7.2.4 Setting Up The Network Connection
7.2.4.1
Setting Up The Network Adaptor
The hardware version of the CommServer can have up to two Ethernet network connections. Each network connection is set up from Windows network configuration.
Note: Adaptor cards for the hardware CommServer, such as the optional
Ethernet card, are normally installed by Psion Teklogix at the factory as part of a customer order. They can also be installed at an authorized service centre.
A network card must be configured if you are installing the Communications Server software on your own hardware. You will need the make and model number of the
Ethernet card, and the driver for the card.
To configure a network card:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Add New Hardware. The Add New Hardware wizard appears.
4. Follow the steps to add the new Ethernet interface.
7.2.4.2
Specifying The CommServer’s TCP/IP Settings
If you will be using Internet Protocol (IP) over a network interface, certain parameters must be set up for the network interface. These are set through the
CommServer’s Windows networking interface.
Psion Teklogix 9500 Communications Server User Manual
141
Chapter 7: Set-Up For 2392 Emulation
Setting Up The Network Connection
To set up the IP parameters of the network interface:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Network and Dial-Up Connections. The Network and
Dial-Up Connections window appears, with a LAN connection for the new interface.
4. Right-click on the LAN connection. A pop-up menu appears.
5. Select Properties. A Properties window appears listing the network interface and the protocols it supports; the network interface is named at the top of this window.
6. Select the TCP/IP protocol from the list.
7. Press the Properties button. The IP Properties window appears.
8. Set the parameters as follows:
Use DHCP: Unselect this radiobutton. The other parameters on this page become available.
IP address: Enter the IP address of the CommServer’s network adaptor.
Subnet Mask: Enter a network mask for this interface.
Default gateway: Enter the IP address of the default gateway. Packets not destined for the local subnet will be sent to this address unless there are other options.
DNS: Enable this parameter to use DNS.
7.2.4.3
Setting Up The CommServer’s Host Table
The host table matches host names to IP addresses. If DNS is not being used, and a static host table is desired for the CommServer, the Windows host table can be modified to include the desired host entries. The host table file is located in the directory
C:\WINNT\System32\drivers\etc
. Its name is simply hosts
(with no filename extension). Entries in the Windows host table take preference over those provided by software such as DNS.
142
Psion Teklogix 9500 Communications Server User Manual
Chapter 7: Set-Up For 2392 Emulation
Setting Up The Network Connection
Note: The term host in this context refers to any device with an IP address,
including parts of the Psion Teklogix system such as the CommServer and its associated base stations.
This use of host is common in the networking field. It should be
distinguished from Psion Teklogix’s use of host versus terminal.
To manually add an entry to the CommServer’s host table:
9. Open the host table file in a text editor.
Entries in the host table appears as follows:
127.0.0.1 localhost
10. Add another line with the hostname of the host, and its IP address.
7.2.4.4
Setting Up The CommServer’s Routing Table
The routing table is used when the CommServer and the host are not connected directly on a single physical network segment.
Packets are routed between network segments to the network connections depending on the packets’ destination addresses and on the contents of the
CommServer’s hosts and routing table.
To add an entry to the CommServer’s routing table:
1. Select Start, Settings, Control Panel. The Control Panel opens.
2. Select Routing and Remote Access. The Routing and Remote Access window opens. This window has a tree at the left-hand side.
Note: Help for the Routing and Remote Access window is available by selecting
Action, Help, or by pressing the Help icon.
3. Click on the name of the CommServer. The tree expands to show the choices for the CommServer.
4. Click on IP Routing. The tree expands to show the choices for the
CommServer’s IP routing.
Psion Teklogix 9500 Communications Server User Manual
143
Chapter 7: Set-Up For 2392 Emulation
Setting Up The Network Connection
5. Click on Static Routes. A list appears at right; any hosts already in the routing table will be listed here.
6. Right-click on the list. A pop-up menu appears.
7. Select New Route... from the menu. The New Static Route dialog box appears.
8. Set these parameters as follows:
Interface: select Local Area Connection.
Destination: Enter the IP address of the host.
If the host is on the same subnet as the CommServer, enter its address here and in the Gateway textbox.
Subnet Mask: Set this parameter to 255.255.0.0.
Gateway: Enter the router’s IP address in this textbox. This device must be on the same subnet as the CommServer, and must be capable of sending packets to the host. If the host is on the same subnet as the CommServer, enter its address here and in the Destination textbox.
Note: The IP addresses on this screen must be entered as four decimal numbers
(from 000 to 255 inclusive). The dialog box automatically skips the dots.
Metric Count: Leave this parameter at 1.
9. Press the OK button. The new route appears in the list.
Close the Routing and Remote Access dialog box.
7.2.4.5
Setting Up The Host Connection
On the main configuration screen, a new host can be defined, or an existing host selected, from the Hosts listbox. Pressing the Configure button next to the Hosts listbox opens the Configure New Host screen for new hosts, or the Host Menu screen for existing hosts.
144
Psion Teklogix 9500 Communications Server User Manual
Chapter 7: Set-Up For 2392 Emulation
Setting Up The Network Connection
Follow these steps to set up a new host connection as host number one in this CommServer:
1. Select Create New in the Hosts listbox
2. Press the Configure button. The CommServer displays the Configure
New Host screen.
The Configure New Host Screen
General properties of the new host connection are set here in the Configure
New Host screen.
3. Set these parameters as follows:
Host Name: Enter a name for the new 2392/Telnet host in this textbox.
Enabled: Place a check mark in this checkbox. The new 2392/Telnet host will be enabled and active.
Emulation and Protocol: Choose an emulation and protocol combination for this host from this drop-down listbox. Only certain combinations of emulation and protocol are available. Select the 2392/Telnet combination.
Psion Teklogix 9500 Communications Server User Manual
145
Chapter 7: Set-Up For 2392 Emulation
Setting Up The Network Connection
Terminal Range: This pair of parameters has two text boxes. In the left box, enter the lowest terminal number which will be assigned to this host, and in the right box enter the highest terminal number which will be assigned to this host.
4. Press the OK button. The CommServer displays a screen confirming that changes have been made.
5. Press OK on this screen. The CommServer displays the
Configuration Main Menu. The Hosts listbox now has an entry for the newly-defined host.
6. Select the new host from the Hosts listbox.
7. Press the Configure button. The CommServer displays the Host Menu:
The Host Menu
Each item on the Host Menu has an associated button.
The button associated with General Options, the first item on the Host
Menu, displays the General Host Options screen. This screen has the same options as the New Host screen, except that there is also a Delete button which removes the host connection from the CommServer’s configuration.
No options need be changed on the General Host Options screen.
8. Press the Configure button associated with Emulation Options. The
CommServer displays the 2392 Emulation Options screen shown on page 147.
146
Psion Teklogix 9500 Communications Server User Manual
The 2392 Emulation Options Screen
Chapter 7: Set-Up For 2392 Emulation
Setting Up The Network Connection
Set the parameters on this screen as follows:
Send CR With FKEY: Leave this checkbox unselected.
Psion Teklogix 9500 Communications Server User Manual
147
Chapter 7: Set-Up For 2392 Emulation
Setting Up The Network Connection
Alarm, Clear, Passthru, Procedures, Local, TSF/O, Host Print,
Remote Print: Leave these checkboxes unselected.
Pages: Leave this textbox at its default of 8.
Transmit Line, AIAG, Visible Match Character, Hidden Match Character, Serial I/O, Print Line, Print Form Length, Barcode, Entry Line,
Field Overhead, Command Region: Leave these textboxes at their defaults of zero.
9. Press the OK button at the bottom of the ANSI parameter screen. The
CommServer displays the Host Menu.
10. Press the Configure button associated with Protocol Options. The
CommServer displays the Protocol Options screen:
The 2392 Telnet Protocol Options Screen
11. Set the parameters on this screen as follows:
Host Port: This textbox contains the port number on the host to which the
CommServer directs telnet connection-requests. Leave this parameter at its default of 23.
148
Psion Teklogix 9500 Communications Server User Manual
Chapter 7: Set-Up For 2392 Emulation
Setting Up The Network Connection
Maximum Sessions Per Terminal: This text box indicates the maximum number of 2392 telnet sessions which will be allowed to originate from each terminal. Leave this parameter at its default of 4.
Close Host Sessions on Terminal Reset: If this checkbox is selected, all host sessions will be closed when the terminal resets. If the checkbox is unselected, the sessions will remain open if the terminal resets.
First Local Terminal Port: This textbox specifies the port number from which the CommServer attempts a telnet connection for the first terminal.
Additional telnet sessions are assigned higher port numbers. Set this parameter to 16100.
Local IP Address To Bind: Enter the IP address of the CommServer on the
Ethernet network in this textbox.
First Terminal Listen Port: This textbox specifies the lowest port number at which the CommServer listens for telnet connections initiated by the host. Leave this parameter at its default of 10000.
Auto-Telnet/Auto-Login Enable Listbox: This listbox enables the user to disable or enable automatic connection of telnet sessions from terminals to this host.
The choices provided are disable, and auto-telnet. Leave this listbox at its default of disable.
When auto-telnet is disabled, telnet sessions from the terminals to the host must be initiated manually from the terminals.
Auto-telnet Host: Enter the name or IP address of the host in this textbox.
The Telnet protocol parameters are now set up. Next, the function-key parameters can be set up.
12. Press the OK button at the bottom of the Protocol Options screen. The
CommServer displays the Host Menu.
13. Press the Configure button associated with Function Key Mappings.
The CommServer displays the 2392 Function Key Mappings screen:
Psion Teklogix 9500 Communications Server User Manual
149
Chapter 7: Set-Up For 2392 Emulation
Setting Up The Network Connection
The 2392 Function Key Mappings Screen
14. Press the OK button at the bottom of the 2392 Function Key Mappings screen. The CommServer displays the Host Menu.
The CommServer is now configured for a 2392 Telnet connection to the host.
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the Com m-
Server’s emulation software. See page C-181 in Appendix C,
“The 9500 CommServer’s Web Interface”.
150
Psion Teklogix 9500 Communications Server User Manual
S
ET
-U
P
F
OR
3274 E
MULATION
8
8.1 Types Of Connections . . . . . . . . . . . . . . . . . . . . . .153
8.2 3274/SNA Over Ethernet . . . . . . . . . . . . . . . . . . . .154
8.2.1 Physical Connection . . . . . . . . . . . . . . . . .154
8.2.2 Host Configuration: 3274 SNA . . . . . . . . . . . .155
8.2.3 CommServer Configuration: 3274 SNA . . . . . . .157
8.3 3274 TCP/IP Over Ethernet . . . . . . . . . . . . . . . . . . .173
8.3.1 Physical Connection . . . . . . . . . . . . . . . . .173
8.3.2 Host Configuration: 3274 TCP/IP . . . . . . . . . .173
8.3.3 CommServer Configuration: 3274 TCP/IP . . . . . .175
Psion Teklogix 9500 Communications Server User Manual
151
Chapter 8: Set-Up For 3274 Emulation
Types Of Connections
8.1 Types Of Connections
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
ANSI
TESS
PTX
Handler Software
HTTP Server
Host Computer
PTX
Emulation
Software
PTX CommServer
Base
ANSI
Terminal
Software
TESS
Web
Browser
HTTP
Terminal
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
ANSI
TESS
PTX
Handler Software
PTX
Emulation
Software
PTX CommServer
Base
ANSI
Terminal
Software
TESS
Web
Browser
HTTP
Terminal
HTTP Server
Host Computer
Figure 8.1 3274 Datastreams In The Psion Teklogix System
Psion Teklogix 9500 Communications Server User Manual
153
Chapter 8: Set-Up For 3274 Emulation
3274/SNA Over Ethernet
The Psion Teklogix Communications Server can emulate an IBM 3274 controller connected to a number of IBM terminals. The emulation software inside the
CommServer converts the 3270 data transparently to and from TESS or HTTP data which is then sent to and from the Psion Teklogix radio-linked terminals.
The CommServer can be connected to its base stations and terminals in a number of ways. These are transparent to the IBM host.
Several types of connections are possible between the CommServer and the IBM host:
• 3274 SNA over Ethernet.
This is described in Section 8.2 on page 154.
• 3274 TCP/IP over Ethernet.
This is described in Section 8.3 on page 173.
8.2 3274/SNA Over Ethernet
8.2.1 Physical Connection
SNA over Ethernet
host
10Base-T
100Base-T
9500
CommServer
10Base-T
100Base-T
Ethernet Network
SNA SNA
Figure 8.2 Ethernet Connections
Ethernet connections run at a speed of 10 or 100 megabits per second. Ethernet networks running at 10 Mb/s use cable types 10Base-T, 10Base5 and 10Base2, which use RJ45, DC-15 and BNC connectors, respectively. Ethernet networks running at 100 Mb/s use 100Base-T cables, which also use RJ45 connectors.
154
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
Host Configuration: 3274 SNA
Important: Using SNA requires that third-party SNA software be installed.
The hardware version of the Communications Server has this software pre-installed; for installations of Psion Teklogix Communications Server on other hardware, the SNA software must be installed before the Psion Teklogix software.
The CommServer’s onboard Ethernet connection supports 10Base-T and
100Base-T Ethernet.
8.2.2 Host Configuration: 3274 SNA
The following are examples of host definitions for 3274 / SNA over Ethernet. The example is from an IBM mainframe. The more important definitions (as far as the
Psion Teklogix system is concerned) are highlighted.
Important: These examples are mere guidelines and might not be identical to the listings you find on your IBM host (due to differences in operating system versions, etc.).
THE HOST SETUP SHOULD BE PERFORMED BY
QUALIFIED PERSONNEL, WHO ARE FAMILIAR WITH
ITS CONFIGURATION!
Psion Teklogix 9500 Communications Server User Manual
155
Chapter 8: Set-Up For 3274 Emulation
Host Configuration: 3274 SNA
IBM Mainframe Example
TRCT1 PU
EXAMPLE DEFINITION IN VTAM
ADDR=C2, (or any 2 hex characters)
ANS=CONTINUE,
IDBLK=017,
IDNUM=000C2,
DLOGMOD=D4A32782,
DISCNT=NO,
IRETRY=YES,
ISTATUS=ACTIVE,
MODETAB=RAMODE,
MAXDATA=2042,
MAXOUT=7,
MAXPATH=2,
PUTYPE=2,
VPACING=0,
USSTAB=USSSNA00,
(no pacing)
T10DX01 PATH
DIALNO=400000000002
.
.
.
L01
L02
L03
LU
LU
LU
LOCADDR=02
LOCADDR=03
LOCADDR=04
USSTAB=USSNA
DLOGMOD=SNA32782
(default table)
(default table)
*
TOKENTIC GROUP
NCP GEN SPECIFICATION FOR TOKEN RING
ECLTYPE=PHYSICAL,
NPACOLL=NO,
PUDR=NO,
COMPTAD=YES,
COMPSWP=YES,
COMPOWN=YES,
TYPE=NCP,
PUTYPE=1,
MAXPU=1,
156
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
TOKENLIN1 LINE
SPEED=9600,
LNCTL=SDLC,
DIAL=NO,
ADDRESS=(10088,FULL),
ADAPTER=TIC2,
LOCADDR=400037450000,
Notes:
1. The
IDBLK
should always be “017”.
2. The
IDBLK
and
IDNUM
parameters together should match the “Exchange
Identifier” parameter in the CommServer configuration. See page 160.
3. The
MAXDATA
parameter corresponds to the Maximum PIU Size parameter configured for the network connection on the CommServer.
4. This is the physical address of the CommServer’s network card.
5. The first device address is always“
02
”, the second “
03
”, and so on.
6. All tables are IBM-supplied defaults for 3274, 3277 and 3278.
7. This is the physical address of the host’s network card. This parameter corresponds to the Destination Address parameter in the SNA Parameters screen for the host connection. See page 163.
8.2.3 CommServer Configuration: 3274 SNA
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface.”
The following is a sample configuration of a Psion Teklogix CommServer connected over an Ethernet line to an IBM host. This example is consistent with the configuration on the IBM host.
Only the relevant parameters in each screen are described here. For a complete definition of all the elements in each screen of the Psion Teklogix software, please refer to Appendix C, “The 9500 CommServer’s Web Interface”.
Psion Teklogix 9500 Communications Server User Manual
157
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
The configuration process on the CommServer has a number of steps:
• Setting SNA and network interface parameters for the CommServer.
• Configuring the host connection, including emulation options, protocol options, and function keys.
These steps are described in the following sections.
8.2.3.1
Setting Up The Network Adaptor
The hardware version of the CommServer can have up to two Ethernet network connections. Each network connection is set up from Windows network configuration.
Note: Adaptor cards for the hardware CommServer, such as the Ethernet card supplied with the CommServer, are normally installed by Psion Teklogix at the factory as part of a customer order. They can also be installed at an authorized service centre.
A network card must be configured if you are installing the Communications Server software on your own hardware. You will need the make and model number of the
Ethernet card, and the driver for the card.
To configure a network card:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Add New Hardware. The Add New Hardware wizard appears.
4. Follow the steps to add the new Ethernet interface.
8.2.3.2
Specifying The Controller’s SNA Parameters
A number of SNA settings apply to the CommServer as a whole. Specify these through the IBM Personal Communications software installed in the CommServer.
This software may be configured through the CommServer’s desktop interface.
The following parameters need to be configured for the CommServer:
158
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
Network Name:
The name for the network where this CommServer is connected.
If the CommServer is connected to the same local network as the host, this parameter corresponds to the Local Network ID parameter of the “Network
Attributes” at the host. See page 156.
Local Control Point Name:
The CommServer’s local control point name. This parameter identifies the
Psion Teklogix CommServer on the SNA network, and matches the host’s
Controller Description parameter.
Exchange Identifier:
This parameter corresponds to the Exchange Identifier parameter in the line description at the host. See page 159.
8.2.3.3
Setting The CommServer’s SNA Options (LUA to LU2)
The CommServer’s SNA options are set through the IBM Personal
Communications software. To configure this software:
1. Open the CommServer’s desktop interface.
2. Double-click on the SNA Node Configuration icon
(illustrated at right).
The SNA Node Configuration dialog box appears:
Psion Teklogix 9500 Communications Server User Manual
159
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
This box has a list of configuration options, and a section below where the configuration of the selected option can be changed or modified.
Note: Help for SNA configuration is available by selecting Help,
Using Node Configuration.
3. Select Configure Node in the SNA Node Configuration dialog box.
The dialog box shows the Node Name textbox.
Note: Configure Node may be selected by default.
4. Press the New button at the bottom. The Define A Node dialog box appears:
5. Enter the fully qualified Control Point name and alias of the local node.
6. Enter the Local Node ID (the XID or exchange identifier). This value must be unique, and is generally of the format
017 xxxxx
.
160
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
7. Click the Advanced tab. The Define A Node dialog box changes to reveal new parameters:
8. Uncheck the with Central Directory Server parameter.
9. Click the DLU Requester tab.The Define A Node dialog box changes to reveal new parameters:
10. Enter “APPN.xxxxx” for the DLUS name, where xxxxx is the name of the primary dependent logical unit server (DLUS) with which a connection is to be established. For example, NET1.CP000346 is a
DLUS name.
11. Click the OK button. The Define A Node dialog box disappears.
12. Select Configure Devices in the SNA Node Configuration dialog box. The dialog box changes to show the DLC Type and LAN
Devices listboxes.
13. Select a DLC Type of LAN.
Psion Teklogix 9500 Communications Server User Manual
161
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
14. Press the New button next to the LAN Devices listbox. The Define A
LAN Device box appears:
Note: If you have multiple interfaces, or wish to use a different SAP, you will have to select the appropriate interface and SSAP first.
15. Click the OK button. The Define A LAN Device box disappears.
16. Select Configure Connections from the listbox in the SNA Node
Configuration dialog box.The SNA Configuration dialog box changes to reflect the choices for this option:
162
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
17. Press the New button. The Basic tab of the Define A LAN Connection dialog box appears.
18. Enter the destination MAC address.
19. Select an address type of Ethernet.
20. Click the Activation tab.The following parameters appear.
Psion Teklogix 9500 Communications Server User Manual
163
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
21. Uncheck the APPN support parameter.
22. Check the Solicit SSCP sessions parameter. The default PU should appear (DIRPU000). In most cases, you will not need to change this value.
23. The Maximum PIU Size parameter for this connection corresponds
to the MAXDATA parameter at the host (see page 157). Set this
parameter to 2042.
24. Click the Adjacent Node tab. The following parameters appear.
25. Enter the CP name of the remote host.
Note: In most cases the provided value should be correct. Check the SNA Node
Configuration utility help for more details).
26. Click the OK button.The Define A LAN Connection dialog box disppears.
27. Select Configure Local LU 0 to 3 from the listbox in the SNA Node
Configuration dialog box. The Local LU 0 to 3 list appears.
164
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
28. Press the New button. The Define a Local LU 0 to 3 dialog box appears:
29. Enter the LU Name, which should be of the form @LUAxxxx. This value must be unique.
30. Enter the NAU address, a value between 2-254. This value must be unique as well, and should match the equivalent value entered on the
AS/400, in the display device profile. Select the correct PU name
(usually the DIRPU000 value seen earlier).
31. Click the OK button. The Define a Local LU 0 to 3 dialog box disappears.
32. Repeat steps 28 to 31 for each LU to be configured. One LU is required
for each configured Psion Teklogix terminal.
33. Select File, Save As. The Save As dialog appears.
34. Select an appropriate name for the configuration file.
35. Press the Save button. The Save As dialog disappears and the configuration file is saved, with an extension of
.acg
.
36. Select File, Select Default File. The Select Default File dialog appears.
37. Select the configuration file that was just created.
38. Press the OK button. The Select Default File dialog disappears and the selected file becomes the default.
Psion Teklogix 9500 Communications Server User Manual
165
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
Important: This file will receive all the changes in SNA parameters by the Psion Teklogix software as well as the Windows configuration software.
39. Select File, Exit. The SNA Configuration dialog box disappears.
The CommServer is now set up for 3274/SNA communication with the host.
8.2.3.4
Setting Up The Host Connection
To define a new host connection for the IBM host on the CommServer:
40. Select Create New in the Hosts listbox on the
Configuration Main Menu.
41. Press the associated Configure button:
The CommServer displays the Configure New Host screen:
166
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
Set the options in this screen as follows:
Name: Enter a name for the new host connection. This name is used in the various menus and screens that mention this host.
Warning: Do not put a period (“.”) in the host name.
Enabled: Select this checkbox to enable the new host connection.
Emulation and Protocol: Select 3274 / SNA for emulation and protocol.
Terminal Range: Enter the range 1 to 32 for this host.
The number in the first box is mapped to the first host terminal number.
The number in the second box is mapped to the last host terminal number.
For example, if you have two hosts defined, and you want Psion Teklogix terminals 1 and 2 to communicate with Host #1 and the rest with Host #2, you need to specify the range “1...2” for Host #1 and the range “3...32” for Host #2.
In this case, Psion Teklogix terminal #1 will be mapped to the first logical
unit (LU) on the first host (LOCADDR=02), and Psion Teklogix terminal #2 will be mapped to the second LU on the first host
(LOCADDR=03). Psion Teklogix terminal #3 will be mapped to the first
logical unit (LU) on the second host (LOCADDR=02), and Psion Teklogix terminal #32 will be mapped to the 30th LU on the second host
(LOCADDR=29).
42. Press the OK button. The CommServer displays the Configuration
Main Menu.
43. Select the name of the new host connection from the Hosts listbox in the Configuration Main Menu.
44. Press the associated Configure button:
Psion Teklogix 9500 Communications Server User Manual
167
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
The CommServer displays the Host Menu for the new host connection:
The Configure button associated with General Options displays the
General Host Options screen. Since this screen contains the same information as the Configure New Host screen, with the addition of a Delete button, there is no need to display it.
168
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
45. Press the Configure button associated with Emulation Options. The
CommServer displays the 3274 Emulation Options screen:
Psion Teklogix 9500 Communications Server User Manual
169
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
46. Set the options in this screen as follows:
Is Host Fujitsu, Use International EBCDIC, Allow Null Character in
Fixed Field: Leave these checkboxes unselected.
Terminal Protocol: Leave this listbox at its default of TESS/BCM to communicate with Psion Teklogix terminals using TESS.
Alarm, Clear, Passthru, Procedures, Local, TSF/O, Host Print, Remote
Print: Leave these checkboxes unselected.
Pages: Leave this textbox at its default of 16.
Transmit Line, AIAG, Visible Match Character, Hidden Match Character, Serial I/O, Print Line, Print Form Length, Barcode, Entry Line,
Field Overhead, Command Region: Leave these textboxes at their defaults of zero.
The HTML/HTTP options are not used in this example and may be left at their defaults.
47. Press the OK button. The CommServer displays the Configuration
Main Menu.
48. Press the Configure button associated with Protocol Options. The
CommServer displays the 3274 SNA Protocol Options screen:
49. Set the options in this screen as follows:
Attention Key: Leave this parameter at its default value.
Use SSCP Sessions: Leave this parameter at its default value.
170
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
50. Press the OK button. The CommServer displays the Host Menu.
51. Press the Configure button associated with Function Key
Mappings. The CommServer displays the 3274 / SDLC Function
Key Mappings screen:
52. Click on the listbox for a function key. A drop-down list appears containing possible choices for that function key.
53. Select the new value from the choices.
Note: Remember that the label of the listbox in this screen specifies the
physical function key, and that the text within the box determines its
function. For example, in the screen shown above, “F26” has been mapped to “F16”, which means that the text “F16” has been selected in the position corresponding to “F26”—the 27th box in this screen.
Psion Teklogix 9500 Communications Server User Manual
171
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 SNA
The 3274 emulator converts the terminal function keys to 3274 Attention
Identifier (AID) characters. The acceptable text for these keys is shown
Text
ENTER
F1 to F24
PA1
PA2
PA3
CLEAR
RESET
SESS
SYSREQ
TSTREQ
AID Character
<E
NTER
> key
Program Function keys <PF1> to <PF24>
<PA1> Program Access key
<PA2> (CNCL) Program Access key
<PA3> Program Access key
<PA4> (Clear) Program Access key
<R
ESET
> key
Opens a new Telnet session
<S
YS
R
Q
> key
<T
EST
> key
Table 8.3 The 3274 AID Character Corresponding To The Text
Note: The <E
NTER
> key on the terminal will only trigger a transmission to the host if the Psion Teklogix terminal is configured to operate the
<E
NTER
> key as “function 0” (F0). Consult the Psion Teklogix Terminal
User Manual for more information.
54. Press the OK button. The CommServer displays the Host Menu.
55. Press the OK button. The CommServer displays the Configuration
Main Menu.
The CommServer is now configured for an SNA connection over Ethernet to an IBM host.
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
172
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
3274 TCP/IP Over Ethernet
8.3 3274 TCP/IP Over Ethernet
8.3.1 Physical Connection
The following diagrams show typical connections and cabling:
TCP/IP over Ethernet
host
10Base-T
10Base2
10Base5
100Base-T
Ethernet Network
10Base-T
10Base2
10Base5
9500
CommServer
100Base-T
TCP/IP TCP/IP
Figure 8.4 Ethernet Connections
Ethernet connections run at a speed of 10 or 100 megabits per second. Ethernet networks use cable types 10Base-T, 10Base5 and 10Base2, which use RJ45, DC-15 and BNC connectors, respectively. Only 10Base-T and 100Base-T Ethernet connections are available on the CommServer’s main logic board.
8.3.2 Host Configuration: 3274 TCP/IP
The following is an example of the definitions on an IBM AS/400.
The more important definitions (as far as the Psion Teklogix system is concerned) are highlighted.
Important: These examples are guidelines and might not be identical to the listings you find on your host (due to differences in operating system versions, etc.).
THE HOST SETUP SHOULD BE PERFORMED BY
QUALIFIED PERSONNEL, WHO ARE FAMILIAR WITH
ITS CONFIGURATION!
Psion Teklogix 9500 Communications Server User Manual
173
Chapter 8: Set-Up For 3274 Emulation
Host Configuration: 3274 TCP/IP
LINE DESCRIPTION
Line description . . . . . . . :
Option . . . . . . . . . . . . :
Category of line . . . . . . . :
Resource name . . . . . . . . :
Online at IPL . . . . . . . . :
Vary on wait . . . . . . . . . :
Network controller . . . . . . :
Local adapter address . . . . :
Exchange identifier . . . . . :
Ethernet standard . . . . . . :
Maximum controllers . . . . . :
Error threshold level . . . . :
Text . . . . . . . . . . . . . :
LIND
RSRCNAME
ONLINE
VRYWAIT
ADPTADR
EXCHID
MAXCTL
ENETLINE
*BASIC
*ELAN
LIN021
*YES
*NOWAIT
RFCTRLENET
08005AB7C3FD
05629A5A
*ALL
40
*OFF
--Source Service Access Points-- --Source Service Access Points--
SSAP Maximum Frame Type SSAP Maximum Frame Type
AA 1496 *NONSNA
Option . . . . . . . . . . . . :
Category of line . . . . . . . :
Link speed . . . . . . . . . . :
Cost/connect time . . . . . . :
Cost/byte. . . . . . . . . . . :
Security for line . . . . . . :
Propagation delay . . . . . . :
User-defined 1 . . . . . . . . :
User-defined 2 . . . . . . . . :
User-defined 2 . . . . . . . . :
Autocreate controller . . . . :
*APPN
*ELAN
10M
0
0
*NONSECURE
*LAN
128
128
128
*NO
CONTROLLER DESCRIPTION
Controller description . . . :
Option . . . . . . . . . . . . :
Category of controller . . . :
Attached line . . . . . . . . :
Online at IPL . . . . . . . . :
Text . . . . . . . . . . . . . :
CTRD
ONLINE
RFCTRLENET
*BASIC
*NET
ENETLINE
*YES
*BLANK
TCP/IP LINK
Line description . . . . . . . :
Internet address . . . . . . . :
Link type. . . . . . . . . . . :
Auto start link . . . . . . . :
DEVD ENETLINE
50.0.1.1
*ELAN
*YES
Note: The
Internet address
is the host IP address entered into the
CommServer’s Windows IP configuration.
174
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
8.3.3 CommServer Configuration: 3274 TCP/IP
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
The following is a sample configuration of a CommServer connected over an
Ethernet line to an IBM host. This example is consistent with the configuration on the IBM host.
Only the relevant parameters in each screen are described here. For a complete definition of all the elements in each screen, please refer to Appendix C, “The 9500
CommServer’s Web Interface”.
Setup of the 9500 CommServer requires the following steps:
• Configuring the network interface.
• Configuring the CommServer’s IP settings, including the host and routing tables.
• Configuring the host connection, including emulation options, protocol options, and function keys.
These steps are described in the following sections.
The hardware version of the CommServer can have up to two Ethernet network connections. Each network connection is set up from Windows network configuration.
Note: Adaptor cards for the hardware CommServer, such as the Ethernet card supplied with the CommServer, are normally installed by Psion Teklogix at the factory as part of a customer order. They can also be installed at an authorized service centre.
A network card must be configured if you are installing the Communications Server software on your own hardware. You will need the make and model number of the
Ethernet card, and the driver for the card.
To configure a network card:
1. Open the CommServer’s desktop interface.
Psion Teklogix 9500 Communications Server User Manual
175
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Add New Hardware. The Add New Hardware wizard appears.
4. Follow the steps to add the new Ethernet interface.
8.3.3.1
Specifying The Controller’s TCP/IP Settings
TCP/IP settings are configured through the CommServer’s Windows networking interface.
To set up the IP parameters of the network interface:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Network and Dial-Up Connections. The Network and Dial-Up
Connections window appears, with a LAN connection for the new interface.
4. Right-click on the LAN connection. A pop-up menu appears.
5. Select Status. A Status window appears.
6. Press the Properties button. A Properties window appears listing the network interface and the protocols it supports; the network interface is named at the top of this window.
7. Select the TCP/IP protocol from the list.
8. Press the Properties button. The IP Properties window appears.
9. Set the parameters as follows:
Use DHCP: Unselect this radiobutton. The other parameters on this tab become available.
IP address: Enter the IP address of the CommServer’s network adaptor.
Subnet Mask: Enter a network mask for this interface.
176
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
8.3.3.2
Setting Up The Controller’s Host Table
The host table matches host names to IP addresses. If DNS is not being used, and a static host table is desired for the CommServer, the Windows host table can be modified to include the desired host entries. The host table file is located in the directory:
C:\WINNT\System32\drivers\etc
.
Its name is simply hosts
(with no filename extension). Entries in the Windows host table take preference over those provided by software such as DNS.
Note: The term host in this context refers to any device with an IP address,
including parts of the Psion Teklogix system such as the CommServer and its associated base stations.
This use of host is common in the networking field. It should be
distinguished from Psion Teklogix’s use of host versus terminal.
To manually add an entry to the CommServer’s host table:
10. Open the host table file in a text editor.
Entries in the host table appears as follows:
127.0.0.1 localhost
11. Add another line with the hostname of the host, and its IP address.
This IP address should match the Internet Address parameter at the host
8.3.3.3
Setting Up The Host Connection
A new host connection needs to be defined on the CommServer for the IBM host.
1. Select Create New in the Hosts listbox n the Configuration Main Menu.
2. Press the associated Configure button:
Psion Teklogix 9500 Communications Server User Manual
177
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
The CommServer displays the Configure New Host screen:
3. Fill in the entries as follows:
Name: Enter a name for the new host connection. This name is used in the various menus and screens that mention this host.
Warning: Do not put a period (“.”) in the host name.
Enabled: Select this checkbox to enable the new host connection.
Emulation and Protocol: Select 3274 / Telnet for the emulation and protocol.
Terminal Range: Enter the range 1 to 32 for this host.
The number in the first box is mapped to the first host terminal
number. The number in the second box is mapped to the last host
terminal number.
To modify the numbers, highlight the box and type the number. After you have done so, press <E
NTER
>.
178
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
For example, if you have two hosts defined, and you want Psion Teklogix terminals 1 and 2 to communicate with Host #1 and the rest with Host #2, you need to specify the range “1...2” for Host #1 and the range “3...32” for Host #2.
There can also be an overlap between terminal ranges of two or more hosts.
For example, you can specify the range “1...5” for the first host and “3...32” for the second host. Those terminals which are in both ranges – 3, 4, 5 in this case – will be able to select which one of the two hosts they connect to.
4. Press the OK button. The CommServer displays the Configuration
Main Menu.
5. Select the name of the new host connection in the Hosts listbox on the
Configuration Main Menu.
6. Press the associated Configure button:
Psion Teklogix 9500 Communications Server User Manual
179
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
The CommServer displays the Host Menu for the new host connection:
The Configure button associated with General Options displays the
General Host Options screen. Since this screen contains the same information as the Configure New Host screen, with the addition of a Delete button, there is no need to display it.
180
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
7. Press the Configure button associated with Emulation Options to display the 3274 Emulation Options screen:
Psion Teklogix 9500 Communications Server User Manual
181
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
Fill in the entries on this screen as follows:
Is Host Fujitsu, Use International EBCDIC, Allow Null Character in
Fixed Field: Leave these checkboxes unselected.
Terminal Protocol: Leave this listbox at its default of TESS/BCM to communicate with Psion Teklogix terminals using TESS.
Alarm, Clear, Passthru, Procedures, Local, TSF/O, Host Print,
Remote Print: Leave these checkboxes unselected.
Pages: Leave this textbox at its default of 16.
Transmit Line, AIAG, Visible Match Character, Hidden Match Character, Serial I/O, Print Line, Print Form Length, Barcode, Entry Line,
Field Overhead, Command Region: Leave these textboxes at their defaults of zero.
Since the terminal protocol is TESS, the HTML/HTTP options are not active and may be ignored.
8. Press the OK button. The CommServer displays the Configuration
Main Menu.
9. Press the Configure button associated with Protocol Options. The
CommServer displays the 3274 / Telnet Protocol Options screen:
182
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
10. Set the options in this screen as follows:
Terminal Type: Select IBM 3278-2.
Host Port: Leave this textbox at its default of 23.
Maximum Sessions per Terminal: Leave this parameter at its default of 4.
First Local Terminal Port: Leave this textbox at its default of 0.
Local IP Address to Bind: Set this to the IP address of the network inter-
face used by the CommServer for this host connection (see Section 8.3.3.1,
“Specifying The Controller’s TCP/IP Settings”). This parameter becomes
more important when the CommServer has more than one network interface using IP.
First Terminal Listen Port: Leave this textbox at its default of 10000.
Psion Teklogix 9500 Communications Server User Manual
183
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
Actively Negotiate With Host, Configure LU Names, LU Name Prefix,
Send IAC Interrupt Process as a System Request, Send IAC Break as
an Attention Key: Leave these checkboxes unselected.
Auto-telnet/login Enable, Auto-telnet Host: Leave these parameters at their default values.
11. Press the OK button. The CommServer displays the Configuration
Main Menu.
12. Press the Configure button associated with Function Key Mappings to display the 3274 / Telnet Function Key Mappings screen:
To change a function of a key, click on the listbox for that function key and select the new value from the choices.
Note: Remember that the label of the listbox in this screen specifies the
physical function key, and that the text within the box determines its
function. For example, in the screen shown above, “F26” has been
184
Psion Teklogix 9500 Communications Server User Manual
Chapter 8: Set-Up For 3274 Emulation
CommServer Configuration: 3274 TCP/IP
mapped to “ATTN”. The text “ATTN” has been selected in the listbox corresponding to “F26”—the 27th listbox in this screen.
The 3274 emulator converts the terminal function keys to Attention
Identifier (AID) characters. The acceptable text for these keys can be found
Text
ENTER
F1 to F24
PA1
PA2
PA3
CLEAR
RESET
SESS
SYSREQ
TSTREQ
AID Character
<E
NTER
> key
Program Function keys <PF1> to <PF24>
<PA1> Program Access key
<PA2> (CNCL) Program Access key
<PA3> Program Access key
<PA4> (Clear) Program Access key
<R
ESET
> key
Opens a new Telnet session
<S
YS
R
Q
> key
<T
EST
> key
Table 8.5 The 3274 AID Character Corresponding To The Text
Note: The <E
NTER
> key on the terminal will only trigger a transmission to the host if the Psion Teklogix terminal is configured to operate the
<E
NTER
> key as “function 0” (F0). Consult the Psion Teklogix Terminal
User Manual for more information.
13. Press the OK button. The CommServer displays the Main
Configuration Screen.
The CommServer is now configured for a TCP/IP connection to the host over Ethernet.
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
Psion Teklogix 9500 Communications Server User Manual
185
S
ET
-U
P
F
OR
5250 E
MULATION
9
9.1 Types Of Connections . . . . . . . . . . . . . . . . . . . . . .189
9.2 5250 SNA (LU6.2) Over Ethernet . . . . . . . . . . . . . . . .190
9.2.1 Physical Connection . . . . . . . . . . . . . . . . .190
9.2.2 Host Configuration: 5250 SNA . . . . . . . . . . . .191
9.2.3 CommServer Configuration: 5250 SNA . . . . . . .196
9.3 5250 TCP/IP Over Ethernet . . . . . . . . . . . . . . . . . . .218
9.3.1 Physical Connection . . . . . . . . . . . . . . . . .218
9.3.2 Host Configuration: 5250 TCP/IP . . . . . . . . . .218
9.3.3 CommServer Configuration: 5250 TCP/IP . . . . . .221
Psion Teklogix 9500 Communications Server User Manual
187
Chapter 9: Set-Up For 5250 Emulation
Types Of Connections
9.1 Types Of Connections
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
PTX
Emulation
Software
Base
ANSI
Terminal
Software
TESS
HTTP
Web
Browser
Terminal
ANSI
TESS
PTX
Handler Software
HTTP Server
Host Computer
9500 CommServer
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
ANSI
TESS
PTX
Handler Software
PTX
Emulation
Software
9500 CommServer
Base
ANSI
Terminal
Software
TESS
Web
Browser
HTTP
Terminal
HTTP Server
Host Computer
Figure 9.1 5250 Datastreams In The Psion Teklogix System
Psion Teklogix 9500 Communications Server User Manual
189
Chapter 9: Set-Up For 5250 Emulation
5250 SNA (LU6.2) Over Ethernet
The Psion Teklogix Communications Server can emulate an IBM 5250 controller connected to a number of IBM terminals. The emulation software inside the
CommServer converts the 5250 data transparently to and from TESS or HTTP data which is then sent to and from the Psion Teklogix radio-linked terminals. The
CommServer can be connected to its base stations and terminals in a number of ways. These are transparent to the IBM host.
Several types of connections are possible between the CommServer and the
IBM host:
• 5250 SNA (LU6.2) over Ethernet connection.
This is described in the “5250 SNA (LU6.2) Over Ethernet” section on page 190.
• 5250 TCP/IP over Ethernet connection.
This is described in the “5250 TCP/IP Over Ethernet” section on page 218.
9.2 5250 SNA (LU6.2) Over Ethernet
9.2.1 Physical Connection
SNA over Ethernet
host
10Base-T
100Base-T
Psion Teklogix
CommServer
10Base-T
100Base-T
Ethernet Network
LU6.2
LU6.2
Figure 9.2 Ethernet Connections
Ethernet connections run at a speed of 10 or 100 megabits per second. Ethernet networks running at 10 Mb/s use cable types 10Base-T, 10Base5 and 10Base2, which use RJ45, DC-15 and BNC connectors, respectively. Ethernet networks running at 100 Mb/s use 100Base-T cables, which also use RJ45 connectors.
The CommServer’s onboard Ethernet connection supports 10Base-T and
100Base-T Ethernet.
190
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
Host Configuration: 5250 SNA
9.2.2 Host Configuration: 5250 SNA
The Psion Teklogix CommServer emulates one or more IBM 5251 model-12 controllers. Each model-12 controller can have over 1000 model-11 devices
(terminals) attached to it. To the host, the CommServer appears to be one or more
IBM model-12 controllers, and the Psion Teklogix RF terminals appear to be IBM model-11 devices.
Important: Using SNA requires that third-party SNA software be installed.
The hardware version of the Psion Teklogix Communications
Server has this software pre-installed.
The CommServer can be connected to a host using Ethernet cabling and the SNA protocol. When installing a Psion Teklogix system to be connected to such a host, the following steps should be taken:
1. If necessary, create an Ethernet line description on the host.
This describes the physical connection between the AS/400 host and the
Psion Teklogix Communications Server, the SSAP, the maximum number of model-12 controllers attached to it, and various characteristics of the communications protocol, timing parameters, and so on.
Note: Psion Teklogix recommends that the
Autocreate controllers
parameter in the line description be set to
*YES
, so that controller descriptions and device descriptions will be automatically created when the CommServer is started and connects to the host.
If
Autocreate controllers
is set to
*NO
, the controller descriptions and device descriptions are not automatically created, and the following two steps must be performed:
2. Create APPC controller descriptions on the host, for each IBM controller emulated by the CommServer. The controller description defines the type of controllers attached to the line, their unique addresses, and their communications protocol, timing parameters, etc.
Psion Teklogix 9500 Communications Server User Manual
191
Chapter 9: Set-Up For 5250 Emulation
Host Configuration: 5250 SNA
3. Create device descriptions on the AS/400 for all of the IBM terminals emulated by the CommServer. Device descriptions contain definitions of the type of device (terminal), the specific controller to which they are attached, their unique address, etc.
4. Create virtual devices if necessary.
The following are examples of AS/400 definitions for 5250 SNA over Ethernet.
The more important definitions (as far as the Psion Teklogix system is concerned) are highlighted.
Important: These examples are guidelines and might not be identical to the listings you find on your host (due to differences in operating system versions, etc.).
THE AS/400 SETUP SHOULD BE PERFORMED BY
QUALIFIED PERSONNEL, FAMILIAR WITH THE
AS/400 AND ITS CONFIGURATION!
The Network Description
This is a sample network description.
NETWORK ATTRIBUTES
Current system name . . . . . . . . . . . . : S1029A5A
Pending system name . . . . . . . . . . . :
Local network ID . . . . . . . . . . . . . . : APPN
Local control point name . . . . . . . . . : TLXLCPN
Default local location . . . . . . . . . . : TLXDLLN
Default mode . . . . . . . . . . . . . . . . : BLANK
APPN node type . . . . . . . . . . . . . . . : *ENDNODE
Data compressions . . . . . . . . . . . . . : *NONE
Intermediate data compressions . . . . . . : *NONE
Maximum number of intermediate sessions . : 200
Route addition resistance . . . . . . . . . : 128
Server network ID/control point name . . . : *LCLNETID *ANY
See Note 1
Notes:
1. If the CommServer is to be connected to the same local network as the
AS/400, the
local network ID
parameter must match the “Network
Name” parameter on the CommServer. See page 197.
192
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
Host Configuration: 5250 SNA
The Line Description
This is a line description for Ethernet.
LINE DESCRIPTION
Line description . . . . . . . . . . . . . .
: ETHLINE
Option . . . . . . . . . . . . . . . . . . .
: *BASIC
Category of line . . . . . . . . . . . . . .
: *ELAN
Resource name . . . . . . . . . . . . . . .
: CMN06
Online at IPL . . . . . . . . . . . . . . .
: *YES
Vary on wait . . . . . . . . . . . . . . . . : *NOWAIT
Network controller . . . . . . . . . . . . .
: ETHLINET00
Local adapter address . . . . . . . . . . .
:
0004AC123456
Exchange identifier . . . . . . . . . . . .
:
05612345
Ethernet standard . . . . . . . . . . . . .
: *ALL
Line speed . . . . . . . . . . . . . . . . .
: 10M
Current line speed . . . . . . . . . . . . .
: 10M
Duplex . . . . . . . . . . . . . . . . . . .
: *HALF
Current duplex . . . . . . . . . . . . . . .
: *HALF
Maximum controllers . . . . . . . . . . . .
: 256
Error threshold level . . . . . . . . . . .
: *OFF
Generate test frame . . . . . . . . . . . .
: *YES
Text . . . . . . . . . . . . . . . . . . . .
: *Ethernet Line
----Source Service Access Points---- ----Source Service Access Points-----
SSAP Maximum Frame Type SSAP Maximum Frame Type
04 *1496 *SNA
12 *1496 *NONSNA
AA *1496 *NONSNA
08 *1496 *SNA
0C *1496 *SNA
Link speed . . . . . . . . . . . . . . . . . . .: 10M
Cost/connect time . . . . . . . . . . . . . . .: 0
Cost/byte. . . . . . . . . . . . . . . . . . . .: 0
Security for line . . . . . . . . . . . . . . .: *NONSECURE
Propagation delay . . . . . . . . . . . . . . .: *LAN
User-defined 1 . . . . . . . . . . . . . . . . .: 128
User-defined 2 . . . . . . . . . . . . . . . . .: 128
User-defined 3 . . . . . . . . . . . . . . . . .: 128
Autocreate controller . . . . . . . . . . . . .: *YES
Autodelete controller . . . . . . . . . . . . .: 1440
Recovery limits . . . . . . . . . . . . . . . .:
Count limit . . . . . . . . . . . . . . . . .:
Time interval . . . . . . . . . . . . . . . .:
2
5
See
Psion Teklogix 9500 Communications Server User Manual
193
Chapter 9: Set-Up For 5250 Emulation
Host Configuration: 5250 SNA
Notes:
1. The
Autocreate controller
parameter should be set to “
*YES
”.
This allows the system to automatically configure new controller descriptions and device descriptions for attached Psion Teklogix CommServers when they boot up.
Controller Descriptions
The controller descriptions are created automatically by the host, if the
Autocreate controllers
parameter is set to
*YES
. A typical controller description is shown below.
CONTROLLER DESCRIPTION
Controller description . . . . . . . . . . : TLX9500
Option . . . . . . . . . . . . . . . . . . . : *BASIC
Category of controller . . . . . . . . . . : *APPC
Link type. . . . . . . . . . . . . . . . . . : *LAN
Online at IPL . . . . . . . . . . . . . . . : *NO
Active switched line. . . . . . . . . . . . : ETHERNET
Character code . . . . . . . . . . . . . . . : *EBCDIC
Maximum frame size . . . . . . . . . . . . . : 16393
Remote network identifier . . . . . . . . . : APPN
Remote control point. . . . . . . . . . . . : TLX9500
Initial connection . . . . . . . . . . . . . : *DIAL
Dial initiation . . . . . . . . . . . . . . : *LINKTYPE
Switched disconnect . . . . . . . . . . . . : *YES
Data link role . . . . . . . . . . . . . . . : *NEG
LAN remote adapter address . . . . . . . . : 400000000002
LAN DSAP . . . . . . . . . . . . . . . . . . : 04
LAN SSAP . . . . . . . . . . . . . . . . . . : 04
Text . . . . . . . . . . . . . . . . . . . . : *BLANK
Notes:
1. The AS/400 controller description can be automatically created at startup. In this case, the Local Control Point Name in the CommServer’s
SNA configuration is used. See page 197.
2. If the CommServer is to be connected to a remote network, the Network
Name parameter in the CommServer’s 5250 SNA configuration (see page 197) should match the
Remote network ID
parameter in the
CommServer description.
For connecting to a local network, see page 192.
194
Psion Teklogix 9500 Communications Server User Manual
3. The
LAN remote adapter address
parameter is the physical address of the Psion Teklogix CommServer’s network card. It should match the
MAC Address parameter in the CommServer’s network configuration.
Device Description
This is a device description for an APPC device.
Display Device Description S1029A5A
03/26/99 14:50:56
Device description . . . . . . . . : TLX00004
Option . . . . . . . . . . . . . . : *BASIC
Category of device . . . . . . . . : *APPC
Automatically created . . . . . . : YES
Remote location . . . . . . . . . : TLX00004
Online at IPL . . . . . . . . . . : *NO
Local location . . . . . . . . . . : TLXLCPN
Remote network identifier . . . . : *NETATR
Attached controller . . . . . . . : BB9400
Message queue . . . . . . . . . . : QSYSOPR
Library . . . . . . . . . . . . : *LIBL
Local location address . . . . . . : 00
APPN-capable . . . . . . . . . . . : *YES
Single session:
Single session capable . . . . . : *NO
Text . . . . . . . . . . . . . . . : AUTOMATICALLY CREATED BY QLUS
Mode Descriptions
The mode description specifies options for sessions connecting to the terminals.
Display Mode Description
Mode description . . . . . . . : MODD
Chapter 9: Set-Up For 5250 Emulation
Host Configuration: 5250 SNA
QPCSUPP
See Note 1
Class-of-service . . . . . . . :
Maximum sessions . . . . . . . :
Maximum conversations . . . . :
COS
MAXSSN
MAXCNV
Locally controlled sessions . :
Pre-established sessions . . :
Inbound pacing value. . . . . :
Outbound pacing value . . . . :
Maximum length of request unit:
Data compression . . . . . . . :
LCLCTLSSN
PREESTSSN
INPACING
OUTPACING
MAXLENRU
DTACPR
Inbound data compression . . :
Outbound data compression . . :
INDTACPR
OUTDTACPR
Text . . . . . . . . . . . . . : TEXT
. . . . . . . . . . . . . . . 400 mode entry
#CONNECT
512
512
0
0
7
7
*CALC
*NETATR
*RLE
*RLE
Client Access/
See Note 2
See Note 2
Psion Teklogix 9500 Communications Server User Manual
195
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
Notes:
1. Each mode description can support up to 512 sessions.
If the number of Psion Teklogix terminals in all host descriptions using this mode description exceeds 512, a different description will have to be used.
In this event, you may copy QPCSUPP to a new mode description, and assign a different name to the mode description. Make sure that the name is identical on both the AS/400 description and the “Mode Name” parameter on the CommServer’s “5250 SNA Protocol Options” screen (see page 215).
2. When configuring a mode description, ensure that the maximum number of sessions and conversations (MAXSSN and MAXCNV) are at least as high as the number of terminals specified in the CommServer’s “Host
Configuration” screen (see page 210).
9.2.3 CommServer Configuration: 5250 SNA
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface.”
The following is a sample configuration of a Psion Teklogix Communications
Server connected by a Ethernet network to an AS/400.
Only the relevant parameters in each screen are described here. For a complete definition of all the elements in each screen of the Psion Teklogix software, please refer to Appendix C, “The 9500 CommServer’s Web Interface.”
The setup on the CommServer requires the following steps:
Configure the network card
• Set up the CommServer’s SNA parameters.
• Set up the host connection.
These steps are detailed in the following sections.
196
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
9.2.3.1
Setting Up The Network Adaptor
The hardware version of the CommServer can have up to two Ethernet network connections. Each network connection is set up from Windows network configuration.
Note: Adaptor cards for the hardware CommServer, such as the Ethernet card supplied with the CommServer, are normally installed by Psion Teklogix at the factory as part of a customer order. They can also be installed at an authorized service centre.
A network card must be configured if you are installing the Communications Server software on your own hardware. You will need the make and model number of the
Ethernet card, and the driver for the card.
To configure a network card:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Add New Hardware. The Add New Hardware wizard appears.
4. Follow the steps to add the new Ethernet interface.
9.2.3.2
Specifying The Controller’s SNA Parameters
A number of SNA settings apply to the CommServer as a whole. Specify these through the IBM Personal Communications software installed in the CommServer.
This software may be configured through the CommServer’s desktop interface.
The following parameters need to be configured for the CommServer:
Network Name:
The name for the network where this CommServer is connected.
If the CommServer is connected to the same local network as the host, this parameter corresponds to the Local Network ID parameter of the “Network
Attributes” at the host. See page 192.
Psion Teklogix 9500 Communications Server User Manual
197
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
Local Control Point Name:
The CommServer’s local control point name. This parameter identifies the
Psion Teklogix CommServer on the SNA network, and matches the host’s
Controller Description parameter. See page 194.
Exchange Identifier:
This parameter corresponds to the Exchange Identifier parameter in the line description at the host. See page 193.
9.2.3.3
Setting The Controller’s SNA Options (APPC to LU6.2)
The CommServer’s SNA options are set through the IBM Personal
Communications software. To configure this software:
1. Open the CommServer’s desktop interface.
2. Double-click on the SNA Node Configuration icon
(illustrated at right).
The SNA Configuration dialog box appears:
198
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
This box has a list of configuration options, and a section below where the configuration of the selected option can be changed or modified.
Note: Help for SNA configuration is available by selecting Help,
Using Node Configuration.
3. Select Configure Node in the SNA Node Configuration dialog box.
The dialog box shows the Node Name textbox.
Note: Configure Node should be selected by default.
4. Press the New button at the bottom. The Define A Node dialog box appears:
5. Enter the name of the local control point (the CommServer's name).
6. Enter the control point (CP) alias.
A typical configuration would use APPN.TLX9500 and TLX9500.
Psion Teklogix 9500 Communications Server User Manual
199
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
7. Select the Advanced tab. The Define A Node dialog box changes to reveal new parameters:
8. Uncheck the with Central Directory Server parameter.
9. Press the OK button. The Define A Node dialog box disappears.
10. Select the Configure Devices option. The SNA Configuration dialog box changes to show the DLC Type and LAN Devices listboxes:
200
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
11. Press the New button next to the LAN Devices listbox. The Define A
LAN Device dialog box appears.
Note: If you have multiple interfaces, or wish to use a different SAP, you will have to select the appropriate interface and SSAP first.
12. Press OK. The Define A LAN Device dialog box disappears.
Psion Teklogix 9500 Communications Server User Manual
201
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
13. Select Configure Connections from the listbox.in the SNA Node
Configuration dialog box. The SNA Configuration dialog box changes to reflect the choices for this option:
202
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
14. Press the New button. The Basic tab of the Define A LAN Connection dialog box appears:
Make sure the link name is "LINK0000", and the device name is the one created above (probably LANX_04).
15. Enter the destination MAC address. This corresponds to the Local
adapter address parameter at the host (see page 193).
16. Select Ethernet as the address type.
Psion Teklogix 9500 Communications Server User Manual
203
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
17. Click the Adjacent Node tab. The dialog box changes:
18. Enter the name of the adjacent node, the host you want to communicate with. For this example, configure APPN.VADER for the Adjacent
Node. See page 193.
19. Leave the other fields at their defaults.
20. Click OK. The Define A LAN Connection dialog box disappears.
204
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
21. Select the Configure Partner LU6.2 option. The SNA Configuration dialog box changes to reflect the choices for this option:
22. Click New. The Define A Partner LU6.2 dialog box appears.
23. Enter the Partner LU name, alias, and fully qualified CP name.
24. Click OK. The Define A Partner LU6.2 dialog box disappears, and the new partner name appears in the list.
Psion Teklogix 9500 Communications Server User Manual
205
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
25. Select Configure Local LU6.2. The SNA Configuration dialog box changes to reflect the choices for this option:
26. Click New. The Define Local LU 6.2 dialog box appears:
27. Enter the local LU name and alias. Generally, these values should be the same, and should be the same as the values configured in the
CommServer’s web interface.
Configure one Local LU 6.2 per terminal session. The session limit should be left at 0. The dependent LU box must be unchecked.
206
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
For example, for 10 terminals, with a prefix of TLX, configure 10 local LU
6.2 entries: TLX00001, TLX00002, TLX00003, TLX00004, TLX00005,
TLX00006, TLX00007, TLX00008, TLX00009, TLX00010.
28. Press the OK button. The Define Local LU 6.2 dialog box disappears.
29. Select Configure Modes. The SNA Configuration dialog box changes to reflect the choices for this option:
30. Select QPCSUPP from the list of modes at the bottom.
31. Click View/Change/Add. The Define a Mode dialog box appears:
Psion Teklogix 9500 Communications Server User Manual
207
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
32. Change the PLU mode session limit to be greater than the number of
LUs configured.
33. Change the number of contention winners to be at least half this value.
34. Select the Advanced tab:
35. Change the maximum negotiable session limit to the same value configured for the PLU mode session limit.
36. Press OK. The dialog box disappears.
37. Select File, Save As. The Save As dialog appears.
38. Select an appropriate name for the configuration file.
39. Press the Save button. The Save As dialog disappears and the configuration file is saved, with an extension of .acg.
40. Select File, Select Default File. The Select Default File dialog appears.
41. Select the configuration file that was just created.
42. Press the OK button. The Select Default File dialog disappears and the selected file becomes the default.
208
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
Important: This file will receive all the changes in SNA parameters made by the Psion Teklogix software as well as the Windows configuration software.
43. Select File, Exit. The SNA Configuration dialog box disappears.
9.2.3.4
Setting Up The Host Connection
To define a new host connection for the IBM host:
44. Select Create New in the Hosts listbox on the Configuration
Main Menu.
45. Press the associated Configure button:
The CommServer displays the Configure New Host screen:
46. Enter the parameters for the host connection as follows:
Name: Enter a name for the new host connection. This name is used in the various menus and screens that mention this host.
Psion Teklogix 9500 Communications Server User Manual
209
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
Warning: Do not put a period (“.”) in the host name.
Enabled:
Select this checkbox to enable the new host connection.
Emulation and Protocol:
Select 5250 / SNA for the emulation and protocol combination.
Terminal Range:
Enter the range 1 to 15 for this host.
47. Press the OK button. The CommServer displays the Configuration
Main Menu.
48. Select the name of the new host in the Hosts listbox on the
Configuration Main Menu.
49. Press the associated Configure button:
210
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
The CommServer displays the Host Menu for the new host:
The General Options button causes the CommServer to display the 5250 /
Ethernet General Options screen. These options have already been set in the Configure New Host screen; nothing need be changed here.
50. Press the Configure button associated with Emulation Options.
Psion Teklogix 9500 Communications Server User Manual
211
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
The CommServer displays the 5250 Emulation Options screen:
212
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
This screen contains options for Psion Teklogix’ 5250 emulation, and for the CommServer’s two methods of providing screens of information to terminals: TESS, the Psion Teklogix Screen Subsystem, and HTML.
51. Enter the parameters for the 5250 options as follows:
Write Error Code:
Leave this listbox at its default of Advisory Text.
Field Underline Remapping:
Leave this listbox at its default of None.
Use International EBCDIC:
Leave this checkbox at its default of unselected.
Terminal Protocol:
Leave this listbox at its default of TESS/BCM to communicate with Psion
Teklogix terminals using TESS.
Alarm, Clear, Passthru, Procedures, Local, TSF/O, Host Print, Remote
Print:
Leave these checkboxes at their defaults of unselected.
Pages:
Leave this textbox at its default of 8.
Transmit Line, AIAG, Visible Match Character, Hidden Match Char-
acter, Serial I/O, Print Line, Print Form Length, Barcode, Entry Line:
Leave these checkboxes at their defaults of 0 (zero).
Field Overhead:
Leave this textbox at its default of 5.
Command Region:
Leave these textboxes at their default of 0 (zero).
The HTML/HTTP options are not used in this example and may be left at their defaults.
52. Press the OK button. The CommServer displays the Host Menu.
Psion Teklogix 9500 Communications Server User Manual
213
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
53. Press the Configure button associated with Protocol Options. The CommServer displays the 5250 SNA Protocol Options screen:
This screen contains options for Psion Teklogix’ 5250 protocol emulation.
54. Enter the parameters for the protocol options as follows:
Host Name:
Enter the name of the host computer to which this SNA connection will be made. This parameter must match the Local Control Point Name parameter in the host’s network description (see page 192). The default host name is
TLXLCPN.
User Name:
Enter the user name for the SNA link. This parameter must correspond to a valid account at the host. The default is TEKUSER.
Password:
Enter the password for the SNA link. This parameter must correspond to a valid account at the host. The default is TEKPASS.
214
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
Important: Psion Teklogix recommends that the host administrator create a new account with different username and password for the
CommServer, and change these default values accordingly.
Note: As the contents of the Password field are hidden from view, care should be taken to enter this data in upper case.
Enable Connect Screen:
Leave this checkbox at its default of selected.
Reconnection Timeout:
Leave this textbox at its default of 30.
Maximum Reconnection Attempts:
Leave this textbox at its default of 3.
A number of access modes can be supported by each host. Enter the following parameters for the first access mode:
Name:
Enter the mode name. This parameter must match the Mode Description
parameter in the host’s Display Mode Description (see page 195).
LU Prefix:
Enter the LU Prefix. The CommServer takes these characters and appends a number to yield a unique name for each device. See the first line of the
sample device description on page 195.
First and Last Terminal Numbers:
Set these parameters to 1 and 32.
55. Press the OK button to save the changes. The CommServer displays a confirmation screen:
Psion Teklogix 9500 Communications Server User Manual
215
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
56. This screen contains a button Update LU Session Information. To display the SNA information that will be changed.
Important: The changes are saved to the SNA software’s default configuration file. This file is listed in the window.
The CommServer displays the following summary screen:
57. Press the Update button to make the changes. The CommServer updates the configuration of its SNA software, then displays a confirmation screen.
58. Press the OK button. The CommServer displays the Host Menu.
216
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 SNA
59. Press the Configure button associated with Function Key Mappings.
The CommServer displays the 5250 Function Key Mappings screen:
This screen contains function-key mappings for Psion Teklogix’
5250 emulation.
60. Click on the listbox for a function key. A drop-down list appears containing possible choices for that function key.
61. Select the new value from the choices.
Note: Remember that the label of the listbox in this screen specifies the
physical function key, and that the text within the box determines its
function. For example, in the screen shown above, “F26” has been mapped to “F16”, which means that the text “F16” has been selected
Psion Teklogix 9500 Communications Server User Manual
217
Chapter 9: Set-Up For 5250 Emulation
5250 TCP/IP Over Ethernet
in the position corresponding to “F26”—the 27th box in this screen.
62. Press the OK button. The CommServer displays the Host Menu.
63. Press the OK button. The CommServer displays the Configuration
Main Menu.
The CommServer is now configured for a 5250 SNA host communicating over Ethernet.
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
9.3 5250 TCP/IP Over Ethernet
9.3.1 Physical Connection
The following diagrams show typical connections and cabling:
TCP/IP over Ethernet
Host
10Base-T
10Base2
10Base5
100Base-T
Ethernet Network
10Base-T
10Base2
10Base5
9500
CommServer
100Base-T
TCP/IP TCP/IP
Figure 9.3 Ethernet Connections
Ethernet connections run at a speed of 10 megabits per second. Ethernet networks use cable types 10Base-T, 10Base5 and 10Base2, which use RJ45, DC-15 and BNC connectors, respectively.
9.3.2 Host Configuration: 5250 TCP/IP
The Psion Teklogix Communications Server emulates one or more IBM 5251 model-12 controllers.
218
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
Host Configuration: 5250 TCP/IP
They can be connected to an IBM AS/400 host using Ethernet cabling and the
Internet Protocol (IP). When installing a Psion Teklogix system to be connected to such a host, create an Ethernet line description (if necessary) on the host.
This describes the connection between the AS/400 host and the CommServer, and describes various characteristics of the communications protocol, timing parameters, and so on.
Note: If the
Autocreate controllers
parameter in the line description is set to
*YES
, controller descriptions and device descriptions will be automatically created when the CommServer is started and connects to the host. The following two steps are not needed.
If
Autocreate controllers
is set to
*NO
, no controller descriptions or device descriptions are created.
The following is an example of the definition on an IBM AS/400. The more important definitions (as far as the Psion Teklogix system is concerned) are highlighted.
Important: These examples are mere guidelines and might not be identical to the listings you find on your IBM host (due to differences in operating system versions, etc.).
THE HOST SETUP SHOULD BE PERFORMED BY
QUALIFIED PERSONNEL, WHO ARE FAMILIAR WITH
ITS CONFIGURATION!
Psion Teklogix 9500 Communications Server User Manual
219
Chapter 9: Set-Up For 5250 Emulation
Host Configuration: 5250 TCP/IP
LINE DESCRIPTION
Line description . . . . . . . :
Option . . . . . . . . . . . . :
Category of line . . . . . . . :
Resource name . . . . . . . . :
Online at IPL . . . . . . . . :
Vary on wait . . . . . . . . . :
Network controller . . . . . . :
Local adapter address . . . . :
Exchange identifier . . . . . :
Ethernet standard . . . . . . :
Maximum controllers . . . . . :
Error threshold level . . . . :
Text . . . . . . . . . . . . . :
LIND
RSRCNAME
ONLINE
VRYWAIT
ADPTADR
EXCHID
MAXCTL
ENETLINE
*BASIC
*ELAN
LIN021
*YES
*NOWAIT
RFCTRLENET
08005AB7C3FD
05629A5A
*ALL
40
*OFF
--Source Service Access Points-- --Source Service Access Points--
SSAP Maximum Frame Type SSAP Maximum Frame Type
AA 1496 *NONSNA
Option . . . . . . . . . . . . :
Category of line . . . . . . . :
Link speed . . . . . . . . . . :
Cost/connect time . . . . . . :
Cost/byte. . . . . . . . . . . :
Security for line . . . . . . :
Propagation delay . . . . . . :
User-defined 1 . . . . . . . . :
User-defined 2 . . . . . . . . :
User-defined 2 . . . . . . . . :
Autocreate controller . . . . :
*APPN
*ELAN
10M
0
0
*NONSECURE
*LAN
128
128
128
*YES
TCP/IP INTERFACE
Display TCP/IP Interface
System: S103PXBM
Internet address . . . . . . . . . . . . . . . : 50.0.0.1
See Note:
Subnet mask . . . . . . . . . . . . . . . . . : 255.255.0.0
Line description . . . . . . . . . . . . . . . : ETHERLINE
Line type . . . . . . . . . . . . . . . . . . : *ELAN
Associated local interface . . . . . . . . . . : *NONE
Interface status . . . . . . . . . . . . . . . : Active
Type of service . . . . . . . . . . . . . . . : *NORMAL
Maximum transmission unit . . . . . . . . . . : *LIND
Automatic start . . . . . . . . . . . . . . . : *YES
Note: The
Internet address
is the IP address of the IBM host entered into the CommServer’s Windows IP configuration.
220
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
9.3.3 CommServer Configuration: 5250 TCP/IP
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
The following is a sample configuration of a Psion Teklogix Communications
Server connected using TCP/IP across an Ethernet network to an AS/400.
Only the relevant parameters in each screen are described here. For a complete definition of all the elements in each screen, please refer to Appendix C: The 9500
CommServer’s Web Interface .
Setup of the 9500 CommServer requires the following steps:
• Configuring the network interface.
• Configuring the CommServer’s IP settings, including the host and routing tables.
• Configuring the host connection, including emulation options, protocol options, and function keys.
These steps are described in the following sections.
9.3.3.1
Setting Up The Network Adaptor
The 9500 CommServer can have up to two Ethernet network connections. Each network connection is set up from Windows network configuration; 5250/TCP-IP over Ethernet requires the configuration of an Ethernet connection.
Note: Adaptor cards for the CommServer, such as the Ethernet card supplied with the CommServer, are normally installed by Psion Teklogix at the factory as part of a customer order. They can also be installed at an authorized service centre.
When the card is installed, it must be configured. You will need the make and model number of the Ethernet card, and the driver for the card.
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
Psion Teklogix 9500 Communications Server User Manual
221
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
3. Select Add New Hardware. The Add New Hardware Wizard appears.
4. Follow the wizard’s instructions to add the new Ethernet interface.
9.3.3.2
Specifying The Controller’s TCP/IP Settings
If you will be using Internet Protocol over a network interface, certain parameters must be set up for the network interface. These are set through the CommServer’s
Windows networking interface.
To set up the IP parameters of the network interface:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Network and Dial-Up Connections. The Network and Dial-Up
Connections window appears, with a LAN connection for the new interface.
4. Right-click on the LAN connection. A pop-up menu appears.
5. Select Status. A Status window appears.
6. Press the Properties button. A Properties window appears listing the network interface and the protocols it supports; the network interface is named at the top of this window.
7. Select the TCP/IP protocol from the list.
8. Press the Properties button. The IP Properties window appears.
9. Set the parameters as follows:
Use DHCP:
Unselect this radiobutton. The other parameters on this tab become available.
IP address:
Enter the IP address of the host’s network adaptor (in this example
50.0.0.1). This corresponds to the Internet Address parameter at the host.
222
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
Subnet Mask:
Enter a network mask for this interface.
Default gateway:
Since the host is on the same subnet as the CommServer, enter the host’s IP address here as well as in the IP Address parameter.
DNS:
Unselect this parameter.
9.3.3.3
Setting Up The Controller’s Host Table
The host table matches host names to IP addresses. If DNS is not being used, and a static host table is desired for the CommServer, the Windows host table can be modified to include the desired host entries. The host table file is located in the directory:
C:\WINNT\System32\drivers\etc
.
Its name is simply hosts
(with no filename extension). Entries in the Windows host table take preference over those provided by software such as DNS.
Note: The term host in this context refers to any device with an IP address,
including parts of the Psion Teklogix system such as the CommServer and its associated base stations.
This use of host is common in the networking field. It should be
distinguished from Psion Teklogix’s use of host versus terminal.
To manually add an entry to the CommServer’s host table:
10. Open the host table file in a text editor.
Entries in the host table appears as follows:
127.0.0.1 localhost
11. Add another line with the IP address of the host (50.0.0.1), followed by its hostname. This IP address should match the Internet Address param-
eter at the host (see page 220).
Psion Teklogix 9500 Communications Server User Manual
223
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
9.3.3.4
Setting Up The Host Connection
A new host connection needs to be defined on the Psion Teklogix CommServer for the IBM host. To do this:
12. Select Create New in the Hosts listbox in the Configuration Main
Menu.
13. Press the associated Configure button:
The CommServer displays the Configure New Host screen:
14. Fill in the entries as follows:
Name:
Enter a name for the new host connection. This name is used in the various menus and screens that mention this host.
Warning: Do not put a period (“.”) in the host name.
Enabled:
Select this checkbox to enable the new host connection.
224
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
Emulation and Protocol:
Select 5250 / Telnet for the emulation and protocol.
Terminal Range:
Enter the range 1 to 32 for this host.
The number in the first box is mapped to the first host terminal number.
The number in the second box is mapped to the last host terminal number.
Important: Make sure that the higher number in the range specified here does not exceed the total number of terminals.
To modify the numbers, highlight the box and type the number. After you have done so, press <E
NTER
>.
For example, if you have two hosts defined, and you want Psion Teklogix terminals 1 and 2 to communicate with Host #1 and the rest with Host #2, you need to specify the range “1...2” for Host #1 and the range “3...32” for Host #2.
There can also be an overlap between terminal ranges of two or more hosts.
For example, you can specify the range “1...5” for the first host and “3...32” for the second host. Those terminals which are in both ranges – 3, 4, 5 in this case – will be able to select which one of the two hosts they connect to.
15. Press the OK button. The CommServer displays the Configuration
Main Menu.
16. Select the name of the new host connection in the Hosts listbox on the
Configuration Main Menu.
17. Press the associated Configure button:
Psion Teklogix 9500 Communications Server User Manual
225
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
The CommServer displays the Host Menu for the new host connection:
The Configure button associated with General Options displays the
General Host Options screen. Since this screen contains the same information as the Configure New Host screen, with the addition of a Delete button, there is no need to display it.
18. Press the OK button. The CommServer displays the Host Menu.
226
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
19. Press the Configure button associated with Emulation Options. The
CommServer displays the 5250 Emulation Options screen
Psion Teklogix 9500 Communications Server User Manual
227
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
This screen contains options for Psion Teklogix’ 5250 emulation and for the
CommServer’s two methods of providing screens of information to terminals:
TESS, the Psion Teklogix Screen Subsystem, and HTML.
20. Enter the parameters for the emulation options as follows:
Write Error Code, Field Underline Remapping:
Leave these listboxes at their defaults.
Use International EBCDIC:
Leave this checkbox at its default, unselected.
Terminal Protocol:
Leave this listbox at its default of TESS/BCM to communicate with Psion
Teklogix terminals using TESS.
Alarm, Clear, Passthru, Procedures, Local, TSF/O, Host Print,
Remote Print:
Leave these checkboxes unselected.
Pages:
Leave this textbox at its default of 16.
Transmit Line, AIAG, Visible Match Character, Hidden Match Character, Serial I/O, Print Line, Print Form Length, Barcode, Entry Line,
Field Overhead, Command Region:
Leave these textboxes at their defaults of zero.
Since the terminal protocol is TESS, the HTML/HTTP options are not active and may be ignored.
21. Press the OK button. The CommServer displays the Configuration
Main Menu.
228
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
22. Press the Configure button associated with Protocol Options. The
CommServer displays the 5250 / Telnet Protocol Options screen:
This screen contains options for Psion Teklogix’ 5250 protocol emulation. These parameters apply to TCP/IP networking over Ethernet connections.
23. Enter the parameters for the protocol options as follows:
Terminal Type:
Select the terminal type of IBM 5251-11.
Actively Negotiate with Host:
Deselect this parameter. The following five parameters may then be left at their defaults; they are not used.
Host Port, Maximum Sessions per Terminal, First Local Terminal
Port, Local IP Address to Bind, First Terminal Listen Port: Leave these at their defaults.
Auto-telnet/login enable: Leave this at its default.
Psion Teklogix 9500 Communications Server User Manual
229
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
Auto-telnet host, Local IP Address to Bind, First Terminal Listen Port,
Negotiate Virtual Device Name with host, Virtual Device Name Prefix:
Leave these at their defaults.
Press the OK button. The CommServer displays the Host Menu.
24. Press the Configure button associated with Function Key Mappings.
The CommServer displays the 5250 Function Key Mappings screen:
To change a function of a key, click on the listbox for that function key and select the new value from the choices.
Note: Remember that the label of the listbox in this screen specifies the
physical function key, and that the text within the box determines its
function. For example, in the screen shown above, “F26” has been mapped to “ATTN”. The text “ATTN” has been selected in the listbox corresponding to “F26”—the 27th listbox in this screen.
230
Psion Teklogix 9500 Communications Server User Manual
Chapter 9: Set-Up For 5250 Emulation
CommServer Configuration: 5250 TCP/IP
25. Press the OK button. The CommServer displays the Host Menu.
26. Press the OK button. The CommServer displays the Main Configura-
tion Screen.
The CommServer is now configured for a 5250 TCP/IP host communicating over a
Ethernet link.
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
Psion Teklogix 9500 Communications Server User Manual
231
S
ET
-
UP
F
OR
HTML E
MULATION
10
10.1 Types Of Connections . . . . . . . . . . . . . . . . . . . . .235
10.2 CommServer Configuration: HTML/TESS . . . . . . . . . .236
10.2.1 Setting Up The Network Connection . . . . . . . .236
10.2.2 Setting Up The Host Connection . . . . . . . . . .240
10.3 Operating A Terminal Using HTML Emulation . . . . . . . .245
10.4 How The HTML Emulator Handles Errors . . . . . . . . . .246
Psion Teklogix 9500 Communications Server User Manual
233
Chapter 10: Set-up For HTML Emulation
Types Of Connections
10.1 Types Of Connections
The Psion Teklogix TekHTML emulator allows Psion Teklogix terminals running
TESS to display HTML pages supplied by an external web server:
Data-compression
And Caching Software
ANSI
2392
Host Application
5250
3274
PTX
Emulation
Software
Base
ANSI
Terminal
Software
TESS
Web
Browser
HTTP
Terminal
ANSI
TESS
PTX
Handler Software
9500 CommServer
HTTP Server
Host Computer
Web Server
CommServer with
HTML Emulation
Psion Teklogix Base Station
Terminal
Network
HTML Datastream Using HTTP Protocol
TESS Datastream Using Psion Teklogix’ Protocols
Figure 10.1 HTML Datastreams In The Psion Teklogix System
The HTML emulation in the CommServer accepts HTML pages via the HTTP protocol from a web server. It then converts them to TESS pages, and sends the
TESS pages on to Psion Teklogix terminals via Psion Teklogix’ protocols. It also accepts responses from those terminals, translates them from TESS into the appropriate HTTP format, and sends them via HTTP to the web server.
The terminals must be configured for TESS.
Psion Teklogix 9500 Communications Server User Manual
235
Chapter 10: Set-up For HTML Emulation
CommServer Configuration: HTML/TESS
10.2 CommServer Configuration: HTML/TESS
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
The following is a sample configuration of a Psion Teklogix 9500 Communications
Server connected over an Ethernet line to a web server (an HTTP host).
Only the relevant parameters in each screen are described here. For a complete definition of all the elements in each screen, please refer to Appendix C, “The 9500
CommServer’s Web Interface”.
The configuration process on the CommServer has a number of steps:
• Configuring the network interface.
• Configuring the CommServer’s IP settings, including the host and routing tables.
• Configuring the host connection, including emulation options, protocol options, and function keys.
These steps are described in the following sections.
10.2.1 Setting Up The Network Connection
10.2.1.1 Setting Up The Network Adaptor
The CommServer can have up to two Ethernet network connections. Each network connection is set up from Windows network configuration; HTML/TESS over
Ethernet requires the configuration of an Ethernet connection.
Note: Adaptor cards for the CommServer, such as the Ethernet card supplied with the CommServer, are normally installed by Psion Teklogix at the factory as part of a customer order. They can also be installed at an authorized service centre.
236
Psion Teklogix 9500 Communications Server User Manual
Chapter 10: Set-up For HTML Emulation
Setting Up The Network Connection
10.2.1.2 Specifying The Controller’s TCP/IP Settings
If you will be using Internet Protocol over a network interface, certain parameters must be set up for the network interface. These are set through the CommServer’s
Windows networking interface.
To set up the IP parameters of the network interface:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Network and Dial-Up Connections. The Network and
Dial-Up Connections window appears, with a LAN connection for the new interface.
4. Right-click on the LAN connection. A pop-up menu appears.
5. Select Status. A Status window appears.
6. Press the Properties button. A Properties window appears listing the network interface and the protocols it supports; the network interface is named at the top of this window.
7. Select the TCP/IP protocol from the list.
8. Press the Properties button. The IP Properties window appears.
9. Set the parameters as follows:
Use DHCP: Unselect this radiobutton. The other parameters on this tab become available.
IP address: Enter the IP address of the CommServer’s network adaptor.
Subnet Mask: Enter a network mask for this interface.
Default gateway: Enter the IP address of the default gateway. Packets not destined for the local subnet will be sent to this address unless there are other options.
DNS: Enable this parameter to use DNS.
Psion Teklogix 9500 Communications Server User Manual
237
Chapter 10: Set-up For HTML Emulation
Setting Up The Network Connection
10.2.1.3 Setting Up The Controller’s Host Table
The host table matches host names to IP addresses. If DNS is not being used, and a static host table is desired for the CommServer, the Windows host table can be modified to include the desired host entries. The host table file is located in the directory:
C:\WINNT\System32\drivers\etc
.
Its name is simply hosts
(with no filename extension). Entries in the Windows host table take preference over those provided by software such as DNS.
Note: The term host in this context refers to any device with an IP address,
including parts of the Psion Teklogix system such as the CommServer and its associated base stations.
This use of host is common in the networking field. It should be
distinguished from Psion Teklogix’s use of host versus terminal.
To manually add an entry to the CommServer’s host table:
10. Open the host table file in a text editor.
Entries in the host table appears as follows:
127.0.0.1 localhost
11. Add another line with the hostname of the host, and its IP address.
10.2.1.4 Setting Up The Controller’s Routing Table
The routing table is used when the CommServer and the host are not connected directly on a single physical network segment.
Packets are routed between network segments to the network connections depending on the packets’ destination addresses and on the contents of the
CommServer’s hosts and routing table.
To add an entry to the CommServer’s routing table:
1. Select Start, Settings, Control Panel. The Control Panel opens.
238
Psion Teklogix 9500 Communications Server User Manual
Chapter 10: Set-up For HTML Emulation
Setting Up The Network Connection
2. Select Routing and Remote Access. The Routing and Remote Access window opens. This window has a tree at the left-hand side.
Note: Help for the Routing and Remote Access window is available by selecting
Action, Help, or by pressing the Help icon.
3. Click on CommServer Name (local). The tree expands to show the choices for the CommServer.
4. Click on IP Routing. The tree expands to show the choices for the
CommServer’s IP routing.
5. Click on Static Routes. A list appears at right; any hosts already in the routing table will be listed here.
6. Right-click on the list. A pop-up menu appears.
7. Select New Route... from the menu. The New Static Route dialog box appears.
8. Set these parameters as follows:
Interface:
Select Local Area Connection.
Destination:
Enter the IP address of the host.
If the host is on the same subnet as the CommServer, enter its address here and in the Gateway textbox.
Subnet Mask:
Set this parameter to 255.255.0.0.
Gateway:
Enter the router’s IP address in this textbox. This device must be on the same subnet as the CommServer, and must be capable of sending packets to the host. If the host is on the same subnet as the CommServer, enter its address here and in the Destination textbox.
Note: The IP addresses on this screen must be entered as four decimal numbers
(from 000 to 255 inclusive). The dialog box automatically skips the dots.
Psion Teklogix 9500 Communications Server User Manual
239
Chapter 10: Set-up For HTML Emulation
Setting Up The Host Connection
Metric Count:
Leave this parameter at 1.
9. Press the OK button. The new route appears in the list.
10. Close the Routing and Remote Access dialog box.
10.2.2 Setting Up The Host Connection
A new host connection needs to be defined on the CommServer for the HTML host.
1. Select Create New in the Hosts listbox n the Configuration Main Menu.
2. Press the associated Configure button:
The CommServer displays the Configure New Host screen:
3. Fill in the entries as follows:
Name:
Enter a name for the new host connection. This name is used in the various menus and screens that mention this host.
Warning: Do not put a period (“.”) in the host name.
240
Psion Teklogix 9500 Communications Server User Manual
Chapter 10: Set-up For HTML Emulation
Setting Up The Host Connection
Enabled: Select this checkbox to enable the new host connection.
Emulation and Protocol:
Select HTML for the emulation and protocol.
Terminal Range:
Enter the range 1 to 32 for this host. The number in the first box is mapped to the first host terminal number. The number in the second box is mapped to the last host terminal number.
To modify the numbers, highlight the box and type the number. After you have done so, press <ENTER>.
For example, if you have two hosts defined, and you want Psion Teklogix terminals 1 and 2 to communicate with Host #1 and the rest with Host #2, you need to specify the range “1...2” for Host #1 and the range “3...32” for Host #2.
There can also be an overlap between terminal ranges of two or more hosts.
For example, you can specify the range “1...5” for the first host and “3...32” for the second host. Those terminals which are in both ranges – 3, 4, 5 in this case – will be able to select which one of the two hosts they connect to.
4. Press the OK button. The CommServer displays the Configuration
Main Menu.
5. Select the name of the new host connection in the Hosts listbox on the
Configuration Main Menu.
6. Press the associated Configure button:
Psion Teklogix 9500 Communications Server User Manual
241
Chapter 10: Set-up For HTML Emulation
Setting Up The Host Connection
The CommServer displays the Host Menu for the new host connection:
The Configure button associated with General Options displays the
General Host Options screen. Since this screen contains the same information as the Configure New Host screen, with the addition of a Delete button, there is no need to display it.
242
Psion Teklogix 9500 Communications Server User Manual
Chapter 10: Set-up For HTML Emulation
Setting Up The Host Connection
7. Press the Configure button associated with Emulation Options to display the HTML Emulation Options screen:
Fill in the entries on this screen as follows:
Screen Size (row x col):
These textboxes specify the height and width (in characters) of the virtual screen used by the emulator when it displays the text of web pages. Leave the textboxes at 24 and 80.
Start page:
Add the URL of the host which will serve the HTML pages to the
CommServer. The http://
part of the URL must be present.
Character Width on the Terminal:
Leave this textbox at its default of 8.
Passthru, TSF/O:
Leave these checkboxes unselected.
Psion Teklogix 9500 Communications Server User Manual
243
Chapter 10: Set-up For HTML Emulation
Setting Up The Host Connection
Pages, Transmit Line, Field Overhead:
Leave these textboxes at their defaults of zero.
8. Press the OK button. The CommServer displays the Configuration
Main Menu.
9. Press the Configure button associated with Protocol Options. The
CommServer displays the HTML/TESS Protocol Options screen:
10. There are no configurable options in this screen.
11. Press the OK button. The CommServer displays the Configuration
Main Menu.
12. Press the Configure button associated with Function Key Mappings to display the HTML/TESS Function Key Mappings screen:
244
Psion Teklogix 9500 Communications Server User Manual
Chapter 10: Set-up For HTML Emulation
Operating A Terminal Using HTML Emulation
To change a function key, click on the listbox for that function key and select the new value from the choices.
13. Press the OK button. The CommServer displays the Main Configura-
tion Screen.
The CommServer is now configured to receive HTTP connections and HTML data from a web server over Ethernet.
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
10.3 Operating A Terminal Using HTML Emulation
Web pages are displayed as TESS pages on the terminal screen, subject to
TekHTML’s limitations. A user can freely move the cursor between input fields
(links and data entry areas). If a page has no links, an artificial link to the current page is inserted to allow keyboard input. All pages should have links; however the function-key equivalents of the browser’s back, forward, and home buttons (by default, the <F1>, <F2>, and <F3> keys, respectively) may be used to navigate away from pages.
After users enter data in input fields, they must position the cursor on a button or link field and press <E
NTER
>. Alternatively, they can press a function key to select one of the links on the page. The terminal sends the data entered and the function or
Enter key pressed back to TekHTML.
• When the user selects a link, the browser requests the linked page. Links may be relative or absolute. They are resolved according to RFC 1808.
TekHTML fetches the new page, translates it into TESS, and sends it to the terminal to be displayed.
• When the user selects a button in a form, this form is sent back to the Web server. An
ACTION
attribute of the
<FORM>
tag can also be relative or absolute. Both
GET
and
POST
methods are supported. TekHTML waits for the HTML response from the server, translates it into TESS, and sends it to the terminal.
Psion Teklogix 9500 Communications Server User Manual
245
Chapter 10: Set-up For HTML Emulation
How The HTML Emulator Handles Errors
• When the user presses the <ENTER> key on an <
INPUT>
control but not a button, TekHTML prints an error message to the console and the error log, and redisplays the current page again.
The attribute
<FKEYONENTER>
can be used to remap the <ENTER> key into a function key; the function key is applied when the user presses the <ENTER> key.
All spaces and other special characters (such as
#
,
&
, etc.) are converted into escaped text using the standard application/x-www-form-urlencoded encoding scheme. The only deviation from the standard is for spaces, which are encoded to
%20
rather than to
+
. However, this alternate encoding should be accepted by all web servers.
10.4 How The HTML Emulator Handles Errors
The CommServer’s HTML emulator has several mechanisms for handling errors.
The following is a list of potential errors and what the emulator will do:
• connection to the host not established:
The browser displays the previous screen and unlocks the terminal. The user can submit the request again.
• connection to the host cut off in mid-connection:
If no page data was received, the message “No data on page” appears. If a partial page is received, the emulator displays it as best as it can. The user can attempt to reload the page, by pressing the ‘Back’ button (default F2), then pressing the ‘Forward’ button (default F3).
• file not found:
The server returns a page containing an error message “404: not found”.
The user can go back to the previous page. This error indicates that the web page specified in the link does not exist, or that an unsupported feature, such as redirection, was used.
• forbidden access, etc:
The web server returns a page containing an error message with an error number and error text. The user can go back to the previous page.
246
Psion Teklogix 9500 Communications Server User Manual
Chapter 10: Set-up For HTML Emulation
How The HTML Emulator Handles Errors
Web pages may be displayed differently from what the user expects.
Missing features or text are probably due to unsupported features on the web page, such as frames or style sheets. Strange positioning of text is probably due to complex web pages; nested tables in particular cause text to appear strangely, due to the HTML emulator’s limitations involving tables. Failure to transmit data to the web server is probably due to an unsupported web page feature such as a radio button, checkbox, or complex form.
Psion Teklogix 9500 Communications Server User Manual
247
S
ET
-
UP
F
OR
R
EMOTE
S
OCKETS
11
11.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . .251
11.2 CommServer Configuration: Remote Sockets . . . . . . . . .252
11.2.1 Configuring Radio Link Features . . . . . . . . . .253
11.2.2 Configuring The Network Interface . . . . . . . . .255
11.2.3 Configuring The Remote Sockets Host . . . . . . .257
11.3 Terminal Configuration For Remote Sockets. . . . . . . . . .261
Psion Teklogix 9500 Communications Server User Manual
249
Chapter 11: Set-up For Remote Sockets
Overview
11.1 Overview
The Remote Sockets feature in the 9500 allows application programs in Psion
Teklogix terminals to communicate with devices on an external TCP/IP network.
The intervening Psion Teklogix network is transparently bridged.
Application programs can communicate over TCP/IP networks using standard function calls. The programs are addressable as nodes on the network through one or more combinations of IP address and port number. Such combinations are called sockets.
When a Psion Teklogix system is used, application programs in the terminals are not actually present as nodes on the network. Instead, the programs must communicate with the Psion Teklogix CommServer, and the CommServer provides the desired socket connections to the network.
9500
With Remote Sockets
Terminal
With Remote Sockets
Psion Teklogix Base Station
Program In
Another Server
API
Program
API
Program
50.0.0.1
Transparent Connection Over Psion Teklogix Network
Figure 11.1 Remote Sockets Data Connections In The Psion Teklogix System
This connection is the Remote Sockets interface.
The Remote Sockets API provides a BSD-style socket interface that non-Psion
Teklogix developers can use to connect to hosts, send and receive data, etc., all without the presence of an 802.11 radio or TCP/IP network stack.
Remote sockets are implemented using a proxy mechanism. Any program call made on the terminal causes the proxy mechanism in the terminal to contect the
Communications Server. The Communications Server makes the program call on the network, and receives the result. It then returns the results to the terminal. This mechanism allows the terminal to appear to possess a direct connection to the network, when in reality it does not.
Psion Teklogix 9500 Communications Server User Manual
251
Chapter 11: Set-up For Remote Sockets
CommServer Configuration: Remote Sockets
This has several advantages:
• Remote Sockets allow a terminal with a non-802.11 radio to connect to hosts, and perform many functions that would normally be limited to terminals with a TCP/IP stack.
• The Remote Sockets API provides a consistent, well-known interface familiar to many software developers.
• The amount of bandwidth needed for Remote Sockets can be much less than that needed by the equivalent TCP/IP communications on a wired network. This fits well with the lesser bandwidth of wireless networks.
• The use of remote sockets offloads work from the terminals to the
CommServer, which can handle multiple sockets and high volumes of data.
Each program in the terminal can make one or more connections through the Psion
Teklogix system to the network. Each connection is treated as a separate terminal on the Psion Teklogix system.
11.2 CommServer Configuration: Remote Sockets
Important: Changes to the CommServer configuration will only take effect after verifying, and saving the CommServer’s configuration, and then updating and rebooting the CommServer. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
The following is a sample configuration of a 9500 CommServer using a non-IP radio to connect to four terminals.
Only the relevant parameters in each screen are described here. For a complete definition of all the elements in each screen, please refer to Appendix C, “The 9500
CommServer’s Web Interface”.
The four terminals in this example each have two application programs, each of which can request two Remote Sockets connections. In addition, they each have another emulation which requires one terminal number. Thus, each terminal may need a total of five terminal numbers, and the system potentially requires twenty terminal numbers.
252
Psion Teklogix 9500 Communications Server User Manual
Chapter 11: Set-up For Remote Sockets
Configuring Radio Link Features
The configuration process for Remote Sockets on the CommServer has a number of steps:
• Configuring the Psion Teklogix radio link.
• Configuring the network interface, if one is not already configured.
• Configuring the Remote Sockets ‘host emulation’.
These steps are described in the following sections.
11.2.1 Configuring Radio Link Features
1. Select the Configure button next to Radio Link Features on the
CommServer’s Configuration Main Menu:
The CommServer displays the Radio Link Features screen:
Psion Teklogix 9500 Communications Server User Manual
253
Chapter 11: Set-up For Remote Sockets
Configuring Radio Link Features
In this screen, cellular mode, the automatic radio address range, and the automatic terminal number range are selected.
Fill in the following options:
Operate in Cellular Mode: Select this checkbox to enable cellular mode operation.
Automatic Radio Address: Enter the range 1 to 20 for this host.
The number in the first box is mapped to the first automatically-assignable
radio address. The number in the second box is mapped to the last auto-
matically-assignable radio address.
254
Psion Teklogix 9500 Communications Server User Manual
Chapter 11: Set-up For Remote Sockets
Configuring The Network Interface
Automatic Terminal Number: Enter the range 1 to 20 for this host.
The number in the first box is mapped to the first allowed automatically-
assigned host terminal number. The number in the second box is mapped to the last allowed automatically-assigned host terminal number.
Note: Each Remote Sockets connection made across the Psion Teklogix network requires one terminal number.
Programs using the Remote Sockets emulation can request in total a maximum of 15 terminal numbers for each terminal. The terminal may require additional terminal numbers for other purposes.
The other options do not need to be changed.
2. Press the OK button. The CommServer displays a confirmation screen.
3. Press OK in this screen. The CommServer then displays the
Configuration Main Menu.
11.2.2 Configuring The Network Interface
11.2.2.1 Setting Up The Network Adaptor
The 9500 CommServer can have up to two Ethernet network connections. Each network connection is set up from Windows network configuration; Remote
Sockets over Ethernet requires the configuration of an Ethernet connection.
Note: Adaptor cards for the CommServer, such as the Ethernet card supplied with the CommServer, are normally installed by Psion Teklogix at the factory as part of a customer order. They can also be installed at an authorized service centre.
When the card is installed, it must be configured. You will need the make and model number of the Ethernet card, and the driver for the card.
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Add New Hardware. The Add New Hardware Wizard appears.
4. Follow the wizard’s instructions to add the new Ethernet interface.
Psion Teklogix 9500 Communications Server User Manual
255
Chapter 11: Set-up For Remote Sockets
Configuring The Network Interface
11.2.2.2 Specifying The Controller’s TCP/IP Settings
If you will be using Internet Protocol over a network interface, certain parameters must be set up for the network interface. These are set through the CommServer’s
Windows networking interface.
To set up the IP parameters of the network interface:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Network and Dial-Up Connections. The Network and Dial-Up
Connections window appears, with a LAN connection for the new interface.
4. Right-click on the LAN connection. A pop-up menu appears.
5. Select Status. A Status window appears.
6. Press the Properties button. A Properties window appears listing the network interface and the protocols it supports; the network interface is named at the top of this window.
7. Select the TCP/IP protocol from the list.
8. Press the Properties button. The IP Properties window appears.
9. Set the parameters as follows:
Use DHCP:
Unselect this radiobutton. The other parameters on this tab become available.
IP address:
Enter the IP address of the host’s network adaptor (in this example, it is 50.0.0.1).
Subnet Mask:
Enter a network mask for this interface.
Default gateway:
Since the host is on the same subnet as the CommServer, enter the host’s IP address here as well as in the IP Address parameter.
256
Psion Teklogix 9500 Communications Server User Manual
Chapter 11: Set-up For Remote Sockets
Configuring The Remote Sockets Host
DNS:
Unselect this parameter.
11.2.2.3 Setting Up The Controller’s Host Table
The host table matches host names to IP addresses. If DNS is not being used, and a static host table is desired for the CommServer, the Windows host table can be modified to include the desired host entries. The host table file is located in the directory:
C:\WINNT\System32\drivers\etc
.
Its name is simply hosts
(with no filename extension). Entries in the Windows host table take preference over those provided by software such as DNS.
Note: The term host in this context refers to any device with an IP address,
including parts of the Psion Teklogix system such as the CommServer and its associated base stations.
This use of host is common in the networking field. It should be
distinguished from Psion Teklogix’s use of host versus terminal.
To manually add an entry to the CommServer’s host table:
10. Open the host table file in a text editor.
Entries in the host table appears as follows:
127.0.0.1 localhost
11. Add another line with the IP address of the host (50.0.0.1), followed by its hostname.
11.2.3 Configuring The Remote Sockets Host
A new host connection needs to be defined on the CommServer for the Remote
Sockets emulation.
1. Select Create New in the Hosts listbox n the Configuration Main Menu.
2. Press the associated Configure button:
Psion Teklogix 9500 Communications Server User Manual
257
Chapter 11: Set-up For Remote Sockets
Configuring The Remote Sockets Host
The CommServer displays the Configure New Host screen:
3. Fill in the entries as follows:
Name: Enter a name for the new host connection. This name is used in the various menus and screens that mention this host.
Warning: Do not put a period (“.”) in the host name.
Enabled: Select this checkbox to enable the new host connection.
Emulation and Protocol: Select Remote Sockets for the emulation and protocol.
Terminal Range: For this example, enter the range 1 to 20 for this host.
The number in the first box is mapped to the first terminal number. The number in the second box is mapped to the last terminal number.
The first terminal number must be smaller than the last terminal number.
258
Psion Teklogix 9500 Communications Server User Manual
Chapter 11: Set-up For Remote Sockets
Configuring The Remote Sockets Host
Important: Make sure that the last terminal number, the higher number in the range specified here, does not exceed the total number of terminals.
To modify the numbers, highlight the box and type the number. After you have done so, press <E
NTER
>.
For example, if you have two hosts defined, and you want Psion Teklogix terminals 1 and 2 to communicate with Host #1 and the rest with Host #2, you need to specify the range “1...2” for Host #1 and the range “3...32” for Host #2.
There can also be an overlap between terminal ranges of two or more hosts.
For example, you can specify the range “1...5” for the first host and “3...32” for the second host. Those terminals which are in both ranges – 3, 4, 5 in this case – will be able to select which one of the two hosts they connect to.
Note: Use of overlapping terminal ranges is not recommended for the Remote
Sockets emulation.
4. Press the OK button. The CommServer displays the Configuration
Main Menu. The new Remote Sockets host is added to the
Hosts listbox.
Psion Teklogix 9500 Communications Server User Manual
259
Chapter 11: Set-up For Remote Sockets
Configuring The Remote Sockets Host
The Host Menu
Each item on the Host Menu has an associated button.
The button associated with General Options, the first item on the Host
Menu, displays the General Host Options screen. This screen has the same options as the New Host screen, except that there is also a Delete button which removes the host connection from the CommServer’s configuration.
No options need be changed on the General Host Options screen.
The Remote Sockets emulation has screens for Emulation Options,
Protocol Options, and Function Key Options, but there are no adjustable parameters on any of these screens. They are mentioned here only for reference.
5. Press the Main Menu button at the bottom of the Host Menu screen.
The CommServer displays the Configuration Main Menu.
Important: Changes to the CommServer configuration will only take effect after verifying, and saving the CommServer’s configuration, and then updating and rebooting the CommServer. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
260
Psion Teklogix 9500 Communications Server User Manual
Chapter 11: Set-up For Remote Sockets
Terminal Configuration For Remote Sockets
11.3 Terminal Configuration For Remote Sockets
There are no parameters specific to Remote Sockets in the terminal. The terminals should be configured for the non-IP radios, with parameters set in the usual way. then the application using the Remote Sockets interface needs to be loaded into the terminal.
Psion Teklogix 9500 Communications Server User Manual
261
C
ONNECTING
T
O
B
ASES
12.1 The CommServer And Its Bases . . . . . . . . . . . . . . . .265
12.1.1 Types Of Bases . . . . . . . . . . . . . . . . . . .265
12.1.1.1 The Base Station . . . . . . . . . . . . . . . .265
12.1.1.2 The Remote Radio Module. . . . . . . . . . .265
12.1.1.3 The Access Point . . . . . . . . . . . . . . . .266
12.1.1.4 Differences . . . . . . . . . . . . . . . . . . .266
12.2 Connecting To Bases . . . . . . . . . . . . . . . . . . . . . .268
12.2.1 Connecting To A Networked Base Station . . . . .268
12.2.1.1 Configuring The Network Card . . . . . . . .270
12.2.1.2 Specifying The Controller’s TCP/IP Settings .270
12.2.1.3 Configuring The Base Station Connection. . .271
12.2.1.4 Adding Base Stations To The Host Table . . .274
12.2.1.5 Adding Base Stations To The Routing Table. .274
12.2.2 Connecting To A Networked RRM . . . . . . . . .276
12.2.2.1 Configuring The Network Card . . . . . . . .277
12.2.2.2 Specifying The Controller’s TCP/IP Settings .277
12.2.2.3 Configuring An RRM Group. . . . . . . . . .278
12.2.2.4 Adding The RRMs To The RRM Group. . . .282
12.2.2.5 Adding The RRMs To The Host Table. . . . .284
12.2.2.6 Adding The RRMs To The Routing Table . . .284
12.2.3 Using An Access Point . . . . . . . . . . . . . . .285
12.2.3.1 Configuring The CommServer For TCP Direct287
12
Psion Teklogix 9500 Communications Server User Manual
263
Chapter 12: Connecting To Bases
The CommServer And Its Bases
12.1 The CommServer And Its Bases
The Psion Teklogix Communications Server performs a number of important tasks.
One of these tasks is emulation: the translating of data between the host computer and the RF terminals.
The CommServer also connects to Psion Teklogix bases. Bases contain radios to provide the connection between the wired and wireless networks; they send and receive data with RF terminals.
12.1.1 Types Of Bases
Psion Teklogix systems can use three types of bases: Base Stations, Remote Radio
Modules (RRMs), or Access Points.
12.1.1.1 The Base Station
The base station connects to the CommServer and communicates with Psion
Teklogix’ wireless terminals. Base stations provide the radio link to the terminals, and control the link’s operation and timing. Base stations may be connected to the
CommServer only over a network. The CommServer does not handle serial connections to bases.
The CommServer can connect to a maximum of 254 base stations.
The CommServer supports Psion Teklogix’ model 9150 and 9140 bases.
12.1.1.2 The Remote Radio Module
The remote radio module (RRM) was developed for systems that require timeplexing. In such systems, the network controller controls the poll timing of the bases’ radio links directly.
RRMs may operate in groups: all of the RRMs in a group transmit and receive on the same channel, and the network controller ensures that they transmit alternately.
This is called timeplexing.
There may be more than one group of RRMs in a Psion Teklogix system. The
CommServer can connect to a maximum of 2 groups of RRMs; each group can have a maximum of four RRMs.
Psion Teklogix 9500 Communications Server User Manual
265
Chapter 12: Connecting To Bases
Types Of Bases
Serially-Connected RRMs
Psion Teklogix’ original RRMs were connected directly to Psion Teklogix’ older network controllers (such as the 9300 and 9200) over a serial link. The network controller coordinated the timeplexing of the RRMs directly. Communications delays over the base-to-controller connection were critical in this application; modems and networks were not used.
One of Psion Teklogix’ bases, the 9130, may also be configured to operate as a serial RRM with older network controllers. Psion Teklogix’ model 9120 base operates only as a serial RRM.
Network-Connected RRMs
The Psion Teklogix Communications Server does not support serially-connected
RRMs. However, a network-timeplexing protocol enables it to coordinate the polling of 9150s over a TCP/IP network (Ethernet). The 9150 base can serve in this way as a network-connected RRM.
12.1.1.3 The Access Point
The access point uses radios that operate according to the 802.11 wireless localarea-network standard. Access points control the operation and timing of the radio link to their terminals.
Access points don’t connect to the Psion Teklogix CommServer in the way that base stations do; rather, they serve as MAC-level bridges between the 802.11 wireless network and Ethernet or Token Ring wired networks.
Base stations and RRMs communicate with the CommServer using Psion Teklogixproprietary protocols encapsulated in TCP/IP to carry data over the radio link.
Access points look transparent to the network . The 802.11 standard defines a nonproprietary standard for the radio link; the 802.11 radio link carries Ethernet or
Token Ring data traffic, as wired networks do.
12.1.1.4 Differences
Base stations, RRMs, and access points differ.
266
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Types Of Bases
Access Points
An access point simply serves as a bridge between a wired network and a wireless network. It forwards packets based on their destination hardware (MAC) addresses, transferring them from the wired network to the wireless network and vice versa.
Wireless terminals generally have IP addresses and send their IP packets across the wireless network, through the access point, and across the wired network to their destination.
9500 CommServer
Access Point
Terminal
Wired Protocols
802.11 Wireless Protocols
TCP Packets
TESS Or ANSI Data
Figure 12.1 A Terminal Communicating With A CommServer Through An Access Point
Psion Teklogix access points such as the 9150 can be configured to filter packets, keeping some data out of the wireless network. This reduces traffic on the wireless network.
The terminals must be configured to work with the access point as well.
See the appropriate user manual for the access point for more information.
Base Stations And RRMs
Base stations and RRMs communicate over the radio link using Psion Teklogixproprietary protocols. They can optionally carry IP data over these protocols.
Base stations can be connected to the 9500 CommServer using Psion Teklogix protocol over networked links using the TCP/IP protocol. RRMs may be connected to network controllers using TCP/IP over Ethernet or (on some controllers) Token
Ring networks.
Psion Teklogix 9500 Communications Server User Manual
267
Chapter 12: Connecting To Bases
Connecting To Bases
RRMs may be connected to the CommServer using the TCP/IP protocol. They may be connected to Psion Teklogix’ older network controllers using serial protocols.
CommServer
Base Station
Or RRM
Terminal
Psion Teklogix TCP Protocol
Psion Teklogix Radio Protocols
TESS or ANSI data
Figure 12.2 A Network-Connected Base Station Or RRM
12.2 Connecting To Bases
12.2.1 Connecting To A Networked Base Station
The Psion Teklogix CommServer can connect with base stations through a TCP/IP network link. This requires that the CommServer have at least one TCP/IP network interface installed; this can be the on-board Ethernet interface, or an additional
Ethernet interface card.
To set up the connection, the following steps must be followed:
1. Connect the base station to the network.
2. Configure the base station for the network and the terminals.
3. Connect the CommServer to the network.
4. Configure the CommServer for the network.
268
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Connecting To A Networked Base Station
This manual assumes that the CommServer and the base station have been connected to and are communicating with the network. Further information about the configuration of the base station is available in the appropriate
Base Station User Manual.
CommServer
Base Station
Router
10.16.0.5
10.16.0.1
10.64.0.1
10.64.0.3
Figure 12.3 A Simple Network Containing A CommServer, A Router And A Base Station
In the figure above, the base station is connected to the CommServer through a router. Note that the CommServer has one IP address, the base station has one IP address, but the router has two IP addresses, one on each subnet that it connects to.
This example uses the addresses from this figure.
The following information is necessary for the CommServer, and must match similar parameters on the base station:
• The base station’s IP address (in this example 10.64.0.3).
Note: There is also a port number associated with the base station. This should not be changed from its default.
• The lowest terminal number that will communicate with the base station.
• The message size.
Only the relevant parameters in each screen are described here. For a complete definition of all the elements in each screen, please refer to Appendix C, “The 9500
CommServer’s Web Interface.”
If the CommServer has already been configured for a network card and IP, skip to
Section 12.2.1.3, “Configuring The Base Station Connection.”
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the
CommServer’s emulation software. See page C-181 in
Appendix C, “The 9500 CommServer’s Web Interface”.
Psion Teklogix 9500 Communications Server User Manual
269
Chapter 12: Connecting To Bases
Connecting To A Networked Base Station
12.2.1.1 Configuring The Network Card
The CommServer can have up to two Ethernet network connections. Each network connection is set up from Windows network configuration.
Note: Adaptor cards for the CommServer, such as the Ethernet card supplied with the CommServer, are normally installed by Psion Teklogix at the factory as part of a customer order. They can also be installed at an authorized service centre.
12.2.1.2 Specifying The Controller’s TCP/IP Settings
TCP/IP settings are configured through the CommServer’s Windows networking interface.
To set up the IP parameters of the network interface:
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Network and Dial-Up Connections. The Network and
Dial-Up Connections window appears, with a LAN connection for the new interface.
4. Right-click on the LAN connection. A pop-up menu appears.
5. Select Status. A Status window appears.
6. Press the Properties button. A Properties window appears listing the network interface and the protocols it supports; the network interface is named at the top of this window.
7. Select the TCP/IP protocol from the list.
8. Press the Properties button. The IP Properties window appears.
9. Set the parameters as follows:
Use DHCP:
Unselect this radiobutton. The other parameters on this tab become available.
270
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Connecting To A Networked Base Station
IP address:
Enter the IP address of the CommServer’s network adaptor.
Subnet Mask:
Enter a network mask for this interface.
Default gateway:
Enter the IP address of the router, 10.16.0.1.
DNS:
Disable this feature.
The network interface on the CommServer is now configured.
12.2.1.3 Configuring The Base Station Connection
To add a networked base station to the CommServer’s configuration:
1. Select the Create New item from the Base Stations listbox.
2. Press the associated Configure button. The CommServer displays the
Configure New Base Station screen:
Psion Teklogix 9500 Communications Server User Manual
271
Chapter 12: Connecting To Bases
Connecting To A Networked Base Station
3. Set the items in this screen as follows:
Name:
Enter a name for the new base station. This name will be used in other screens and displays concerning this base station.
Protocol:
Select the TCP/IP protocol to communicate with the base station.
First Terminal:
Leave this parameter at its default of 1.
Message Size:
Leave this parameter at its default of 100.
Enabled:
Select this checkbox to enable the base station. The CommServer will establish communication with the base station when the CommServer is turned on.
4. Press the OK button. The CommServer displays the Configuration
Main Menu; the new base station has been added to the Base Stations listbox.
5. Select the new base station from the Base Stations listbox.
272
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Connecting To A Networked Base Station
6. Press the Configure button associated with the Base Stations listbox.
The CommServer displays the Base Station menu:
7. Press the Configure button associated with General Options. The
CommServer displays the Configure Existing Base Station screen.
The items on this screen are identical to those on the Configure New Base
Station screen, except that this screen also has a Delete button. They do not need to be adjusted.
8. Press the OK button. the CommServer displays the Base Station Menu.
9. Press the Configure button associated with Connectivity Options. The
CommServer displays the Base Station TCP/IP Options screen:
10. Set the items in this screen as follows:
Address:
Set this to the IP address of the base station (in this example 10.64.0.3).
Psion Teklogix 9500 Communications Server User Manual
273
Chapter 12: Connecting To Bases
Connecting To A Networked Base Station
Port:
Set this to the port used by the base station. Usually, the default value of
16100 will do.
11. Press the OK button. The CommServer displays the Base
Station Menu.
12. Press the OK button. The CommServer displays the Configuration
Main Menu.
The CommServer is now set up for the networked base station.
12.2.1.4 Adding Base Stations To The Host Table
It is not necessary to add the base station to the CommServer’s host table.
12.2.1.5 Adding Base Stations To The Routing Table
The CommServer uses the routing table to direct packets to the proper destination when that destination is not directly accessible or is possibly ambiguous.
When the base station is located beyond a router or gateway, the routing table contains the address of the gateway which forwards the data to the base station.
Note: If the CommServer has more than one IP network interface, the routing table may also be used to specify which interface will accept the data for the base.
To add an entry to the CommServer’s routing table:
1. Select Start, Settings, Control Panel. The Control Panel opens.
2. Select Routing and Remote Access. The Routing and Remote Access window opens. This window has a tree at the left-hand side.
Note: Help for the Routing and Remote Access window is available by selecting
Action, Help, or by pressing the Help icon.
3. Click on the entry called <Name> (local), where <Name> is whatever name has been assigned to the Communications Server during setup.
The tree expands to show the choices for the CommServer.
274
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Connecting To A Networked Base Station
4. Click on IP Routing. The tree expands to show the choices for the
CommServer’s IP routing.
5. Click on Static Routes. A list appears at right; any hosts already in the routing table will be listed here.
6. Right-click on the list. A pop-up menu appears.
7. Select New Route... from the menu. The New Static Route dialog box appears.
8. Set these parameters as follows:
Interface:
Select Local Area Connection.
Destination:
Enter the IP address of the base station, 10.64.0.3.
If the host is on the same subnet as the CommServer, enter its address here and in the Gateway textbox.
Subnet Mask: Set this to 255.255.0.0.
Gateway:
Enter the router’s IP address (10.16.0.10) in this textbox. This device must be on the same subnet as the CommServer, and must be capable of sending packets to the base station. If the base station is on the same subnet as the
CommServer, enter its address here and in the Destination textbox.
Note: The IP addresses on this screen must be entered as four decimal numbers (from 000 to 255 inclusive). The dialog box automatically skips past the dots.
Metric Count:
Leave this parameter at 1.
9. Press the OK button. The new route appears in the list.
10. Close the Routing and Remote Access dialog box.
The CommServer is now configured for the networked base station.
Psion Teklogix 9500 Communications Server User Manual
275
Chapter 12: Connecting To Bases
Connecting To A Networked RRM
12.2.2 Connecting To A Networked RRM
The CommServer can connect with Model 9150 Base Stations acting as RRMs through a TCP/IP network link.
This requires that the CommServer have one TCP/IP network interface installed.
To set up the connection, the following steps must be followed:
1. Connect the RRM to the network.
2. Configure the RRM for the network.
3. Connect the CommServer to the network.
4. Configure the CommServer for the network.
5. Set up RRM groups.
6. Assign individual RRMs to groups.
This manual assumes that the CommServer and the RRMs have been connected to and are communicating with the network. Further information about the configuration of the RRM is available in the 9150 User Manual.
CommServer
RRM2
Router
RRM1
10.16.0.5
10.16.0.1
10.64.0.1
10.64.0.3
10.64.0.4
Figure 12.4 A Simple Network Containing A CommServer, A Router And Two RRMs
In the figure above, the RRMs are connected to the CommServer through a router.
The CommServer has one IP address, each RRM has one IP address, but the router has two IP addresses, one on each subnet that it connects to. This example uses the addresses from this figure.
276
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Connecting To A Networked RRM
The following information is necessary for the CommServer, and must match similar parameters on the base station:
• The IP address of each RRM (in this example 10.64.0.3 and 10.64.0.4).
• The port number of the RRM.
Important: For the RRM to communicate with the CommServer, this number must match the port number specified at the RRM itself.
Only the relevant parameters in each screen are described here. For a complete definition of all the elements in each screen, please refer to Appendix C, “The 9500
CommServer’s Web Interface.”
If the CommServer has already been configured for a network card and IP, skip to
Section 12.2.1.3, “Configuring An RRM Group.”
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the CommServer’s emulation software. See page C-181 in Appendix C,
“The 9500 CommServer’s Web Interface”.
12.2.2.1 Configuring The Network Card
The CommServer can have up to two Ethernet network connections. The timeplexing protocol used by RRMs requires a TCP/IP network connection.
Each network connection is set up from Windows network configuration.
Note: Adaptor cards for the CommServer, such as the Ethernet card supplied with the CommServer, are normally installed by Psion Teklogix at the factory as part of a customer order. They can also be installed at an authorized service centre.
12.2.2.2 Specifying The Controller’s TCP/IP Settings
If you will be using Internet Protocol over a network interface, certain parameters must be set up for the network interface. These are set through the CommServer’s
Windows networking interface.
To set up the IP parameters of the network interface:
Psion Teklogix 9500 Communications Server User Manual
277
Chapter 12: Connecting To Bases
Connecting To A Networked RRM
1. Open the CommServer’s desktop interface.
2. Select Start, Settings, Control Panel. The Control Panel appears.
3. Select Network and Dial-Up Connections. The Network and Dial-Up
Connections window appears, with a LAN connection for the new interface.
4. Right-click on the LAN connection. A pop-up menu appears.
5. Select Status. A Status window appears.
6. Press the Properties button. A Properties window appears listing the network interface and the protocols it supports; the network interface is named at the top of this window.
7. Select the TCP/IP protocol from the list.
8. Press the Properties button. The IP Properties window appears.
9. Set the parameters as follows:
Use DHCP:
Unselect this radiobutton. The other parameters on this tab become available.
IP address:
Enter the IP address of the CommServer’s network adaptor.
Subnet Mask:
Enter a network mask for this interface.
Default gateway:
Enter the IP address of the router, 10.16.0.1.
DNS:
Disable this feature.
The network interface on the CommServer is now configured.
12.2.2.3 Configuring An RRM Group
To add RRMs to the CommServer, at least one RRM Group must be added to the CommServer’s configuration:
278
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Connecting To A Networked RRM
1. Select the Create New item from the RRM Groups listbox.
2. Press the associated Configure button.
Psion Teklogix 9500 Communications Server User Manual
279
Chapter 12: Connecting To Bases
Connecting To A Networked RRM
The CommServer displays the Configure New RRM Group screen:
280
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Connecting To A Networked RRM
3. Set the items in this screen as follows:
Name:
Enter a name for the new RRM group. This name will be used in other screens and displays concerning this group.
Communications Protocol:
Select the TCP/IP protocol to communicate with the RRM group.
Enabled:
Place a checkmark in this box to enable the RRM group.
Auto Startup:
Leave this parameter at its default of enabled.
Number of Poll Windows:
Leave this parameter at its default of 0.
Size of Poll Windows:
Leave this parameter at its default of 0.
Maximum Message Segment Size:
Leave this parameter at its default of 100.
Number of Retries:
Leave this parameter at its default of 3.
Collision Size:
Leave this parameter at its default of 6.
Free Window Factor:
Leave this parameter at its default of 0.
Message Mode Limit:
Leave this parameter at its default of 4.
Callsign Period:
Leave this parameter at its default of 0.
Callsign String:
Leave this parameter at its default of Teklogix.
Sync Delay:
Leave this parameter at its default of 28.
Psion Teklogix 9500 Communications Server User Manual
281
Chapter 12: Connecting To Bases
Connecting To A Networked RRM
Remote TxOn:
Leave this parameter at its default of 13.
Active Channel:
Leave this parameter at its default of 1.
Group Parameters:
Leave these textboxes empty.
4. Press the OK button. The CommServer displays the
Configuration Main Menu; the new RRM group has been added to the RRM Groups listbox.
The new RRM group has been added to the CommServer.
12.2.2.4 Adding The RRMs To The RRM Group
The RRMs must now be added to the RRM group.
This example assumes that both RRMs are in the same group. All RRMs in a group transmit on the same radio frequency.
5. Select the new RRM group from the RRM Groups listbox.
6. Press the Configure button associated with the Base Stations listbox.
The CommServer displays the RRM Group Menu:
7. Press the Configure button associated with General Options. The
CommServer displays the Configure Existing RRM Group screen.
282
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Connecting To A Networked RRM
The items on this screen are identical to those on the Configure New RRM
Group screen, except that this screen also has a Delete button. They do not need to be adjusted.
8. Press the OK button. the CommServer displays the RRM Group Menu.
9. Select the Create New option in the listbox associated with RRMs.
10. Press the Configure button associated with RRMs. The CommServer displays the Configure New RRM screen:
11. Set the items in this screen as follows:
Name:
Provide a name for the RRM.
Address:
Set this to the IP address of the RRM (in this example, the address is
10.64.0.3 for the first RRM).
Port:
Set this to the port used by the base station. Usually, the default value of
16100 will do.
Important: The port number must match the port number set at the RRM.
Otherwise, the CommServer cannot communicate with the RRM.
12. Press the OK button. The CommServer displays the
RRM Group Menu.
13. Repeat steps 10 to 12 for the second RRM, using an IP address of 10.64.0.4.
Psion Teklogix 9500 Communications Server User Manual
283
Chapter 12: Connecting To Bases
Connecting To A Networked RRM
14. Press the OK button. The CommServer displays the RRM Group
Menu. Both RRMs have been added to this group.
15. Press the OK button. The CommServer displays the Configuration
Main Menu.
The CommServer is now set up for one RRM group, and both RRMs are in the group.
12.2.2.5 Adding The RRMs To The Host Table
It is not necessary to add the RRMs to the CommServer’s host table.
12.2.2.6 Adding The RRMs To The Routing Table
The CommServer uses the routing table to direct packets to the proper destination when that destination is not directly accessible or is possibly ambiguous.
When an RRM is located beyond a router or gateway, the routing table contains the address of the gateway which forwards the data to the base station.
Note: If the CommServer has more than one IP network interface, the routing table may also be used to specify which interface will accept the data for the RRM.
To add an entry to the CommServer’s routing table:
1. Select Start, Settings, Control Panel. The Control Panel opens.
2. Select Routing and Remote Access. The Routing and Remote Access window opens. This window has a tree at the left-hand side.
Note: Help for the Routing and Remote Access window is available by selecting
Action, Help, or by pressing the Help icon.
3. Click on CommServer Name (local). The tree expands to show the choices for the CommServer.
4. Click on IP Routing. The tree expands to show the choices for the
CommServer’s IP routing.
5. Click on Static Routes. A list appears at right; any hosts already in the routing table will be listed here.
284
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Using An Access Point
6. Right-click on the list. A pop-up menu appears.
7. Select New Route... from the menu. The New Static Route dialog box appears.
8. Set these parameters as follows:
Interface:
Select Local Area Connection.
Destination:
Enter the IP address of the base station, 10.64.0.3.
If the base station is on the same subnet as the CommServer, enter its address here and in the Gateway textbox.
Subnet Mask: Set this to 255.255.0.0.
Gateway: Enter the router’s IP address (10.16.0.10) in this textbox.
This device must be on the same subnet as the CommServer, and must be capable of sending packets to the base station. If the base station is on the same subnet as the CommServer, enter its address here and in the
Destination textbox.
Note: The IP addresses on this screen must be entered as four decimal numbers (from 000 to 255 inclusive). The dialog box automatically skips past the dots.
Metric Count:
Leave this parameter at 1.
9. Press the OK button. The new route appears in the list.
10. Close the Routing and Remote Access dialog box.
There is now a new entry for the RRM in the CommServer’s routing table.
12.2.3 Using An Access Point
The CommServer can communicates with network devices through an access point on a TCP/IP network. This requires that the CommServer have one TCP/IP network interface installed.
To set up the CommServer for a new access point, do the following steps:
Psion Teklogix 9500 Communications Server User Manual
285
Chapter 12: Connecting To Bases
Using An Access Point
1. Connect the access point to the network.
2. Configure the access point for the network.
3. Configure the terminals for the access point and the network.
4. Connect the CommServer to the network.
5. Configure the CommServer for the network.
This manual assumes that the CommServer and the access point have been connected to and are communicating with the network. Further information about the configuration of the access point is available in the appropriate Access Point
User Manual.
The CommServer requires little setup information for terminals to communicate directly with the CommServer using an access point.point to bridge the wired and wireless networks.
The Psion Teklogix Communications Server can communicate directly to a Psion
Teklogix terminal using one of two protocols. The first protocol Psion Teklogix developed was TCP Direct which is a protocol that uses TCP/IP to transfer the data from the terminal to the Psion Teklogix Communications Server. TCP/IP is a protocol that was developed for a wired network where the devices on the network are always present, always powered on and used a physical layer that had a predictable delay.
The physical properties of a wireless network and the fact the most wireless terminals use an aggressive power saving routing means that TCP/IP is not a very efficient or effective protocol for wireless networks, so Psion Teklogix developed
802.IQv2 to overcome some of these inherent problems. 802.IQv2 is an extension of
802.IQv1 that allows a wireless terminal to use a TCP/IP stack. It is a proprietary protocol that uses UDP to communicate between the wireless terminal and the Psion
Teklogix Communications Server. The advantage of the 802.IQv2 protocol is that it is based on Psion Teklogix’ proven WLAN protocol that tracks each terminal and monitors the communications quality and uses this information to adapt the protocol to provide a fast and robust wireless link.
286
Psion Teklogix 9500 Communications Server User Manual
Chapter 12: Connecting To Bases
Using An Access Point
Important: Changes to the CommServer configuration will only take effect after verifying the changes, and then restarting the CommServer’s emulation software. See page C-181 in Appendix C,
“The 9500 CommServer’s Web Interface”.
12.2.3.1 Configuring The CommServer For TCP Direct
To use TCP Direct through networked access points, configure the CommServer as follows:
1. Press the Configure button associated with the Radio Link Features item on the Configuration Main Menu:
2. The CommServer displays the Radio Link Features screen:
Psion Teklogix 9500 Communications Server User Manual
287
Chapter 12: Connecting To Bases
Using An Access Point
3. Select the Direct TCP Connections for TekTerm checkbox.
4. Press the OK button. The CommServer displays the Configuration
Main Menu.
The CommServer is now configured for the networked access point.
288
Psion Teklogix 9500 Communications Server User Manual
S
PECIFICATIONS
13.1 Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . . .291
13.2 Environmental Requirements. . . . . . . . . . . . . . . . . .291
13.3 Power Requirements . . . . . . . . . . . . . . . . . . . . . .291
13.4 Processor And Memory . . . . . . . . . . . . . . . . . . . .291
13.5 LAN Interfaces . . . . . . . . . . . . . . . . . . . . . . . . .291
13.6 Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . .291
13
Psion Teklogix 9500 Communications Server User Manual
289
Chapter 13: Specifications
Physical
13.1 Physical
Enclosure
Dimensions
Weight
Steel with baked enamel finish
43.5 x 53 x 17.5 cm
(17.125 x 20.9 x 6.9 inches)
26 kg (56 pounds)
13.2 Environmental Requirements
Operating Temperature
Operating Rel. Humidity
Storage Temperature
Storage Rel. Humidity
0 to 50°C (32 to 122°F)
5 to 95% (noncondensing)
–40 to 55°C (–40 to 135°F)
10 to 90% (noncondensing)
13.3 Power Requirements
Input voltage
Frequency
Current
90 - 264 VAC (autoranging)
47 - 63 Hz
6A (90 - 132 VAC); 3A (180 - 264 VAC)
13.4 Processor And Memory
Microprocessor
RAM
Pentium-class
512 megabytes
13.5 LAN Interfaces
Ethernet 10Base-T and 100Base-T built in;
10Base-T available with option card.
13.6 Approvals
CSA, UL, TÜV, CE
Psion Teklogix 9500 Communications Server User Manual
291
I
NDEX
A
access point compared with base station
configuring networked access point defined
administration
alarm delay of, for power supply
alert
power supply MTBF termperature
B
base station
defined
configuring networked base station
C
cables
Ethernet
null-modem, for console port chassis
email parameters icon
temperature alert chassis monitoring operating time
communications server defined
configuration
configuration of controller
networked base station networked RRM
Remote Sockets
Remote Sockets over Ethernet
2392 Telnet over Ethernet
configuration of host
ANSI over TCP/IP
configuring
networked base station
networked RRM connection types
console commands
PPP link prompt
username and password
controller descriptions
controls
Psion Teklogix 9500 Communications Server User Manual
i
Index
D
datastreams
HTTP
to HTTP
to TESS
delay
device descriptions
5250 emulation dial-up connection to PPP console port direct connection
disk array administration
alert messages
parameters
synchronization disk array software
disk monitoring software parameters door
dual power-supplies
E
emulation
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
in Psion Teklogix network controllers
errors
Ethernet
events
disk array
F
front-panel
H
hard drive
status LED swappable
hardware
host connection
HTML emulation host table
HTML emulation
and errors
I
icon
disk array management software
indicator
ii
Psion Teklogix 9500 Communications Server User Manual
L
line descriptions
5250 emulation location for installation
dual power-supplies
M
mode descriptions
5250 emulation
MTBF alert
rating defined
N
network adaptor setup for Remote Sockets network descriptions
5250 emulation network interface
IP parameters
network timeplexing defined
networked access point configuring
networked base station configuring networked RRM configuring
O
R
RAID array administration
recipients alert messages from disk array
Remote Radio Module (RRM) defined
Remote Sockets
defined
radio link features removing hard drive
Index
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
installing
operating time for chassis monitoring
operation of terminal with HTML emulation
operation of terminal with Remote Sockets
P
PAP Authentication on PPP console port parameters
power supply
swappable, removing
voltage alert configuration power-on indicator
PPP console port dial-up connection to
username and password
prompt, console
Psion Teklogix 9500 Communications Server User Manual
iii
Index
Boldface
indicates a parameter name, as it appears in the Configuration Program.
Italics indicates a screen name as described in the Web Interface Reference Guide.
RRM
9500 defined
S
safety
serial timeplexing
service information
SNA node configuration icon
software
starting disk arraymonitoring software
switch
alarm silence
T
TCP/IP setup for Remote Sockets
TCP/IP over Ethernet
timeplexing
W
warranty
worldwide offices
5250 emulation controller descriptions
line descriptions mode descriptions
iv
Psion Teklogix 9500 Communications Server User Manual
Preuzimanje
Reklama