UHFReader18 Demo Software User's Guidev2.6
1
UHFReader18 Demo Software User’s Guide v2.6
1. Parameter interface operation
1.1 Open COM Port
Before open com port, please make controller properly connected with the host using the communication cable provided and then turn on the power.then select .
( 1 ) Auto Open Comport:
Value 255(0xFF) is broadcasting address. All controllers will respond the order with a broadcasting address.
Other value (0x00~0xFE) is controller address. Only will the controller conforming to the address respond the operation.
C l i c k , If reader connect the computer's COM1 ~ COM9, we can see the port display in the place. the demonstration software to by connecting the port and written communication, the connection to the port to have a beginning, such as : e lse
( 2) Open Designated Comport:
C l i c k ,the Baud will Auto Select From 115200bps, 57600bps,
38400bps,19200bps, 9600bps,if success else
1.2 Open Net Port
Select
1
(1)Search device by page
(2) Input device TCPIP communication port
(3)click open devide and
1.3 Parameter Setting:
UHFReader18 Demo Software User’s Guide v2.6
and IP close device
( 1 ) the new reader address to set. This address can't be 0xFF.
If set 0xFF, reader will return error information.
( 2) set and save power configuration.
( 3 ) select the reader’s band, different band, the frequency of different。
( 4) Set reader working Min
Frequency and Max Frequency. In different places, the radio requires the rule to be different. Users can follow the local situation and choose to read more sensitive frequency range of the card. In single frequency point operation, only need to set two frequencies to the same value. In frequency hopping operation, only need to set two frequencies to the different value.
( 5 ) demo software start run, default use the baud rate 57600 to open COM port, reader power on, reader baud rate default is 57600.
After change the baud rate, reader use the new baud rate until power off. Close port and open port, the baud rate no change. The demo software will use the new baud rate, until
2
UHFReader18 Demo Software User’s Guide v2.6
close the demo software.
( 6 ) set the inventory scan max response time of reader. If demo software sends the inventory order, it will wait 30*10ms for reader response and exits.
1.4Work mode parameter setting
( 1 ) Wiegand parameter Setting
< 1>
Weigand 26、 34 select.
Weigand output formart select.
<2>
<3>
Settings wergen the output of data at regular intervals, the two sets of data gaps between wergen at least 30 - 10ms.
<4>
10*10us.
Set weigand Pulse Width , this pulse width is the
<5>
Set a pulse. the interval between pulses for 15 - 100us, with the interval between pulses weigand agreement. the impulse to burst the interval between pulses.
( 2) Work mode setting:
Response to the mode of argument is invalid, the initiative in this mode is valid.
< 1>
Set Reader’s support of the protocol. Select
Reader is only support ISO18000-6C ; Select
ISO18000-6B.
Reader is only support
<2> Set o u t p u t m o d e o f act i v e w o r k m o d e. w h e n select
3
show message as
UHFReader18 Demo Software User’s Guide v2.6
p u t o u t R e a de r d ata w i t h R S 2 3 2/R S485. c l i c k
。
<3>
Set u p to the reader w h e n the data is there a b u zzer p r o m p t sou n d.
<4>
Set reader of the tag to read some of the data or checks for the tag of EPC. if the data with a password protected areas then can not read.
<5>
Set the start address and number of to be read,a word is 2 bytes.
Starting address (16 binary):when select
, that Reader support ISO18000-6C protocol , 0 read from the first word(The appropriate storage first16 bit) , 1 read from second word, four times; when select
6B protocol, 0 read from the first byte(The appropriate storage first 8 bit) , 1 read from second byte , four times. if“Start Addr+Read NO.” Greater than the corresponding storage area to read, read and write the address of the data will not read data。
Read NO.(10 binary) : when select
, that Reader support ISO18000-
、 、
, Reader inventory tag’s EPC , And the starting address and read is not; when select
, Read data nmber is 2, can not setting , for this time,if“Start Addr+2” Greater than the corresponding storage area to read, read and write the address of the data will not read data。
<6> Set the start address
( 4)
( 3) Get work mode parameter:
Reader’s waigand and work mode parameter. click this button, can get
.Set EAS accuracy。 Default is 8.
4
( 5)
( 6 ) reader’s Tigger time.
( 7)
UHFReader18 Demo Software User’s Guide v2.6
.Set Syris485 offset time.Default is 0.
Used to get or set
,set two relay release or active.first select then click set button.
2. The Necessary Knowledge
2.1 EPCC1G2 tag memory
Tag memory divided into four storage areas, each storage area can be made up of one or more memory words. The four storage areas:
EPC areas (EPC): Store the area of EPC number, this module stipulates it can store 15 word
EPC number. Can read and can write.
TID areas (TID): Store ID number established by the tag production firm. There are 4 words and 8 words two kinds of ID numbers at present. Can read and not can write.
User areas (User): This area of different manufacturers is different. There is no user area in
G2 tag of Inpinj Company. There are 28 words in Philips Company. Can read and can write.
Password areas (Password): The first two words is kill password, the last two words is access password. Can read and can write.
Can write protect in four storage areas. It means this area is never writeable or not writeable under the non-safe state; only password area can set unreadable.
2.2 18000-6B tag
6B tag has a memory space, the minimum 8 bytes (byte 0- 7) is UID of the tag, and can't be rewritten. Following byte all can be rewritten, can be locked too, but once locking, can't rewrite again, can't unblock either.
2.3 Data display (tag ID, passwords, memory data is display in 16 hexadecimal)
Display in Hex, then 11 is first byte, 22 is second byte, and 1122 is first word.
Total 8 bytes, in other words, total 4 words.
3. EPCC1-G2 Test opration( COM IS OPEN)
5
UHFReader18 Demo Software User’s Guide v2.6
3.1 Query Tag (The operation needing to choose the tag all need to query tag first)
( 1 )
( 2)
Every 50ms issued a command checks.
can see
( 3) Check can see
, input query TID’s parameter,
3.2 Read Data, Write Data, Block Erase
(1) Read data operation
<1> Choose tag
<2> Choose memory
<3> Write
Start address:
0x00 stand in start to read data from first word in the designated storage area
, 0x01 stand in start to read data from second word in the designated storage area
, and so on.
6
UHFReader18 Demo Software User’s Guide v2.6
Read the length: Number of the word to be read. It read 120 words at most.
Can not set 0 or 120, otherwise, return the parameter error information.
Access password:
From left to right it is the former high-word, low word in the access password. I f operation don’t need access password, it can be the arbitrary value, but can't lack.
<4> Click can see
(2) Write data operation
<1> Choose tag
<2> Choose memory
<3> Write
( E P C m e m o r y A d d r ess o f ta g is
2)
Start address: 0x00, the first word of data (from left) is written in address 0x00 of the designated storage area, and so on.
<4> Click can see
(3) Block Erase Operation (write 0 to the designated data )
<1> Choose tag
<2> Choose memory
<3> Write
Start address:
0x00 stand in start to erase data from first word in the designated storage area
, 0x01 stand in start to erase data from second word in the designated
7
UHFReader18 Demo Software User’s Guide v2.6
storage area
, and so on.
The difference from write operation: Needn't fill in the data.
<4> Click can see
(4) Write block operation
<1> Choose tag
<2> Choose memory
<3> Write
( E P C m e m o r y A d d r ess o f ta g is
2)
Start address: 0x00, the first word of data (from left) is written in address 0x00 of the designated storage area, and so on.
<4> Click can see
(4) EPC Mask Enable
<1>
Maskadr : The mask the first byte address.
MaskLen: The mask of bytes length.
(5) Write EPC
<1>check
<2>select
<3>Input new EPC number
<4>click ,if successed, can see
3.3 Revise the password
8
UHFReader18 Demo Software User’s Guide v2.6
(1) Choose tag
(2) Choose memory
(3) Write access password
Access password:
From left to right it is the former high-word, low word in the access password. I f operation don’t need access password, it can be the arbitrary value, but can't lack.
(4) Revise the access password 12345678: Write
(5) Revise the kill password 12345678: Write
Click
Click
(6) If succeed, we can see
3.4 Write EPC (Needn’t query tag)
(1) Write access password (If EPC area of the tag has not set password protection, we can write 8 data arbitrarily)
(2) Write EPC.
(3) Click . (Random write one tag in the effective range of antenna)
When there are many or EPC pieces of tag in the effective range of antenna, and the access
9
UHFReader18 Demo Software User’s Guide v2.6
password of one tag is the same as you entered, or EPC area of tag set no password protection, click at a time, random write EPC number of one tag in the effective range of antenna.
3.5 Set the state of read and write protection
(1) Choose tag
(2) Choose memory
(3) Choose protection type
(4) Write access password:
Any storage area in no password protection status still must write the correct access password.(password can not be zero).
3.6 Read Protection
(1) Set Single Tag Read Protection
10
UHFReader18 Demo Software User’s Guide v2.6
<1> Choose tag
<2> Write tag access password
<3> Click
According to EPC number of the tag, setting read protection, make tag unable to be read and written by any order, even if query the tag, it is unable to get EPC number of the tag.
Only NXP UCODE EPC G2X tags valid.
(2) Set Single Tag Read Protection without EPC
<1> Write tag access password
<2> Click the effective range of antenna
The difference from can set tag read protection in
: When there are several tag in the effective range of antenna, reader don’t know the tag which the order operate.
If operate several tags, then the access password of the tag had better be the same.
Only NXP UCODE EPC G2X tags valid.
(3) Reset Single Tag Read Protection without EPC
<1> Write access password
<2> Click
Use for reset the tag read protection.
Only put a tag in the effective range of antenna.
Only NXP UCODE EPC G2X tags valid.
Comments:
If tag does not support the read protection setting, it must be unprotected.
(4) Detect Single Tag Read Protection without EPC
<1> Click
Can't detect tag whether it support read protection order, can only detect single tag whether it is protected.
If tag does not support the read protection setting, it must be unprotected.
Make sure that there is single tag in the effective range of antenna.
Only NXP
UCODE EPC G2X tags valid.
11
UHFReader18 Demo Software User’s Guide v2.6
3.7 EAS Alarm
(1) Alarm setting
<1> Choose tag
<2> Write access password
<3> Choose alarm
Set or reset the EAS status bit of tag.
Only NXP UCODE EPC G2X tags valid.
(2) Check alarm without EPC and access password
<1> Click check alarm
Check the EAS alarm of tag.
Only NXP UCODE EPC G2X tags valid.
<2> EAS alarm:
No EAS alarm:
3.8 Lock Block for User (Permanently Lock) (After the data locked, it can not be changed again)
(1) Choose tag
12
UHFReader18 Demo Software User’s Guide v2.6
(2) Write
Access password can not be the whole 0. Otherwise, the tag can not be locked, and the tag return response with parameter error.
(3) Choose address of tag data (word). The user’s area amounts to 14 word. (0- 13)
Lock permanently in 2 words. Therefore, the address of tag data is divided into 0 and 1, 2 and 3, 4 and 5, 6 and 7, 8 and 9, 10 and 11, 12 and 13. You can lock the data if you wish:
After the data get locked, it can be read only, can't be rewritten, and can’t be erased too.
Only NXP UCODE EPC G2X tags valid.
3.9 Kill Tag( Permanently Kill)
(1) Choose tag
(2) Write
Kill password can not be the whole 0. Otherwise, the tag can not be killed, and the tag return response with parameter error.
4. 18000-6B Test Interface Operation (After Open COM Port)
4.1 Query Tag
(1) send a inventory command every
50ms.
(2)
Only query the single tag. If many tags are in the effective range of antenna at the same time, it may be unable to query the tag.
(3)
<1> Unequal Condition:
13
UHFReader18 Demo Software User’s Guide v2.6
Note:
The 8 bytes of 6B tag number write in the 0~7 which in the address of tag data (0- 233)
Figure, query condition begin to compare from the tag data address 0. The comparative content is 22.
Click
See
Figure, from the tag number we can see the addresses 0 of tag data: 00, 00, 11, 11.
Unequal condition 22, therefore, the four tags are read.
<2> Equal Condition:
Note:
The 8 bytes of 6B tag number write in the 0~7 which in the address of tag data (0- 233)
Figure, query condition begin to compare from the tag data address 0. The comparative content is 00.
Click
See
14
UHFReader18 Demo Software User’s Guide v2.6
Figure, from the tag number we can see the addresses 0 of tag data: 00, 00.
Equal condition 00, therefore, the two tags are read.
<3> Greater than
Note:
The 8 bytes of 6B tag number write in the 0~7 which in the address of tag data (0- 233)
Figure, query condition begin to compare from the tag data address 0. The comparative content is 00.
Click
See
Figure, from the tag number we can see the addresses 0 of tag data: 11, 11.
Great than 00, therefore, the two tags are read.
15
UHFReader18 Demo Software User’s Guide v2.6
4.2 Read and Write Data Block / Permanently Write Protect Block of Byte
(1)
(2) Read data:
Start address:
0x00 stand in start to read data from first word in the designated storage area
, 0x01 stand in start to read data from second word in the designated storage area
, and so on.
Range is 8~223. Beyond this range, reader will return parameter error.
Read length: pointed to the number of bytes to read. Range is 1~32. If Start address +
Read length
greater than 224, or
Read length
greater than 32 or is zero, reader will return parameter error information. The high bytes of
Read length write in the low address in tag.
(3) Write data:
Write data:
Range is 1~32. If Start address +
Write length
greater than 224, or
Write length
greater than 32 or is zero, reader will return parameter error information. The high bytes of
Read length
write in the low address in tag.
(4) Permanently Write Protect:
lock the designated byte.
(5) Check Protect: check whether the designated byte is locked.
(6) If succeed, we can see:
16
UHFReader18 Demo Software User’s Guide v2.6
5. Frequency Analysis Operation (After Open COM Port)
(1)Click ,can see
The larger of the percentage ,the better of the results.
(2)
This function can set an get hopping mode.
Click ,if successed ,can see
Click
Can see the hopping mode at
6. TCP/IP Config
(1)Click ,if find a device can see
.
(1)Click , If the device is correctly connected with the host, the device’s IP
17
UHFReader18 Demo Software User’s Guide v2.6
address will show up in below text area. This IP address can be changed by clicking
button.
(2) Select device
Click
Setting tab as following:
button to set the TCP/IP interface parameters.Set Network
Set Serial Settings tab as following:
(Remark: Baud rate and Parity should be set according to every device’s serial communication parameters)
18
UHFReader18 Demo Software User’s Guide v2.6
(3)Click button to finish the parameter setting procedure.
The host application software uses socket communication method to exchange information with the device, there is no other configuration procedure needed. The device’s built-in TCP/IP interface supports windows socket communication programming API.
Application software should exchange information with the device using the protocol described in device’s user’s manual
19