ThingMagic Mercury5e, M5e-Compact RFID reader Developer’s Guide
The Mercury5e and M5e-Compact are RFID readers that provide high performance and flexibility. The readers are designed to be used in a variety of applications, such as inventory management, asset tracking, and access control. These readers are capable of communicating with a variety of RFID tags, including Gen2 tags.
Advertisement
Advertisement
Mercury5e and M5e-Compact
Developer’s Guide
For: Mercury5e and M5e-Compact (v1.7.1 and later)
USB Reader and Vega Reader
875-0016-07 RevA
Government Limited Rights Notice: All documentation and manuals were developed at private expense and no part of it was developed using
Government funds.
The U.S. Government’s rights to use, modify, reproduce, release, perform, display, or disclose the technical data contained herein are restricted by paragraph (b)(3) of the Rights in Technical Data — Noncommercial Items clause (DFARS 252.227-7013(b)(3)), as amended from time-to-time. Any reproduction of technical data or portions thereof marked with this legend must also reproduce the markings. Any person, other than the U.S.
Government, who has been provided access to such data must promptly notify ThingMagic, Inc.
ThingMagic, Mercury, Reads Any Tag, and the ThingMagic logo are trademarks or registered trademarks of ThingMagic, Inc.
Other product names mentioned herein may be trademarks or registered trademarks of ThingMagic, Inc. or other companies.
©2012 ThingMagic – a division of Trimble Navigation Limited. ThingMagic and The Engine in RFID are registered trademarks of Trimble Navigation
Limited. Other marks may be protected by their respective owners. All
Rights Reserved.
ThingMagic
A Division of Trimble
One Cambridge Center, 11th floor
Cambridge, MA 02142.
866-833-4069
07 Revision A
January, 2012
Date
2/2008
2/2008
2/2008
3/2008
3/2008
3/2008
3/2008
4/2008
4/2008
4/2008
Revision Table
Rev1
Rev1
Rev1
Rev1
Rev1
Version
Rev1
Rev1
Rev1
Rev2
Rev2
Description
Separated out M4e content and Reader Assistant into standalone documents. Created new M5e Family DevGuide
Updated TX Power section to correct TX Write power note.
Fixed Send CW Signal content with correct value for PRBS signal.
Added input voltage details to M5e/C Hardware comparison table.
Added FCC and IC Regulatory Statements
Updated timestamp field in Tag Read Meta Data description to indicate its ticks from read command invocation.
Added details on new functionality for release 1.0.37:
• M5e EU info (Hardware Support)
• PRC (China) region support (get/set Current Region)
• Support for user control of Gen2 Q value (Get/Set Protocol
Parameter)
• LBT on/off and LBT Threshold setting in supported regions
(Get/Set Current Region) and LBT default settings in
Regulatory Support section.
• Custom NXP Silicon Commands (Tag Specific)
• Get Reader Statistics
• Get tag read metadata with Read Tag Single
• Get tag read metadata with Read Tag Data
• Read Tag Multiple with Tag Singulation
• Read Tag Multiple with embedded commands
• Updates to Tag Select functionality
Added Gen2 Memory Map and algorithm information to Tag Singulation section.
Added information on Transmit mode power consumption to Transmit Modes
Corrected NXP command:
• names: changed ‘Quiet’ to ‘ReadProtect’
• EAS Alarm and Calibrate syntax
3
4
Date
6/2008
9/2008
11/2008
4/2009
6/2009
8/2009
12/2010
3/2011
1/2012
Version Description
Rev3
02 RevA
02 RevA
03 RevA
04 Rev1
04 Rev1
• Fixed Arbser help info to include -l5a for loading M5e firmware
• Fixed Get Tag Buffer Response Fields to show Read Count as conditional
• Added info on EU2 usage and caution
• Update Get/Set Reader Configuration commands to reflect the new key/value pair format
• Fixed the CRC calc sample code
• Fixed PRC region frequency range
• added info about why use Write Tag EPC over Write Tag Data
• Added 1.1.1 features
• fixed response fields - missing metadata field - in Get Tag
Buffer
• Fixed Read Tag Data meta data fields
• KR2 region support info
• misc doc bug fixes
05 Rev1 • Added detail to Tag Singulation/Select section
• Updated RS232 electical specs
• Added MercuryAPI info
• updated copyright and FCC info with new company info
• added note to Lock Tag
06 Rev1 Updates for firmware v1.5.1
• New Custom commands support
• more data returned for embedded tag read data operations.
07 RevA Updates for firmware 1.5.2
• Set Gen2 Write Response Time (under 0x9B)
• IDS SL900A
support
Communication Regulation Information
Communication Regulation Information
EMC FCC 47 CFR, Part 15
Industrie Canada RSS-210
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
This transmitter module is authorized to be used in other devices only by OEM integrators under the following conditions:
1.
The antenna(s) must be installed such that a minimum separation distance of 25cm is maintained between the radiator (antenna) & user’s/nearby people’s body at all times.
2.
The transmitter module must not be co-located with any other antenna or transmitter.
As long as the two conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing their end-product for
5
6
Communication Regulation Information any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.).
Note
In the event that these conditions can not be met (for certain configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product.
In these circumstances, the OEM integrator will be responsible for reevaluating the end product (including the transmitter) and obtaining a separate FCC authorization.
The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user manual of the end product.
User Manual Requirement
The user manual for the end product must include the following information in a prominent location;
“To comply with FCC’s RF radiation exposure requirements, the antenna(s) used for this transmitter must be installed such that a minimum separation distance of 25cm is maintained between the radiator (antenna) & user’s/nearby people’s body at all times and must not be co-located or operating in conjunction with any other antenna or transmitter.”
AND
“The transmitting portion of this device carries with it the following two warnings:
“This device complies with Part 15....”
AND
“Any changes or modifications to the transmitting module not expressly approved by
ThingMagic Inc. could void the user’s authority to operate this equipment” “
End Product Labeling
The final end product must be labeled in a visible area with the following:
“Contains Transmitter Module FCC ID: QV5MERCURY5E”
Communication Regulation Information or
“
Contains FCC ID: QV5MERCURY5E.”
(Replace QV5MERCURY5E, for the Mercury5e, with QV5MERCURY5EC for the M5e-
Compact).
Industry Canada
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication.
This device has been designed to operate with the antennas listed in
Authorized Antennas
.
Antennas not included in this list are strictly prohibited for use with this device.
To comply with IC RF exposure limits for general population/uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.
End Product Labeling
The final end product must be labeled in a visible area with the following:
“Contains ThingMagic Inc. M5e-Compact
(or appropriate model number you’re filing with
IC)
transmitting module FCC ID: QV5MERCURY5EC (IC: 5407A-MERCURY5EC)”
7
8
Communication Regulation Information
Contents
Mercury Embedded Modules Developer’s Guide
9
10
Mercury Embedded Modules Developer’s Guide
Mercury Embedded Modules Developer’s Guide
11
12
Mercury Embedded Modules Developer’s Guide
Mercury Embedded Modules Developer’s Guide
13
14
Mercury Embedded Modules Developer’s Guide
Mercury Embedded Modules Developer’s Guide
15
16
Mercury Embedded Modules Developer’s Guide
FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h. . . . . . . . . . . . . . . . . . . . . . . . 226
Mercury Embedded Modules Developer’s Guide
17
FAULT_TAG_ID_BUFFER_NOT_ENOUGH_TAGS_AVAILABLE – 600h . . . . . . . . . . . . . . . . . . . . . . 230
Appendix D: Deprecated and Modified Commands . . . . . . . . . . . . . . . . . . . . . . . . . . 233
18
Mercury Embedded Modules Developer’s Guide
Mercury Embedded Modules Developer’s Guide
19
20
Mercury Embedded Modules Developer’s Guide
Introduction
The ThingMagic
®
Mercury
®
embedded modules are RFID engines that you can integrate with other systems to create RFID-enabled products.
Applications to control the M5e-Family of modules and derivative products can be written
in the low level Serial Protocol
and also using the high level MercuryAPI.
The MercuryAPI supports Java and .NET environments starting with version 1.1 and C starting with version 1.5. The MercuryAPI Software Development Kit (SDK) contains sample applications and source code to help developers get started demoing and developing functionality. For more information on the MercuryAPI see the
MercuryAPI
Programmers Guide
and the
MercuryAPI SDK
, available on the ThingMagic website.
For assistance using thelow level Serial Protocol
interface called the
Reader Assistant
provides screens to configure the reader, and read from and write to tags and displays the resulting serial commands in its
Serial Log
. In addition, there are screens for updating firmware and debugging. For those communications that cannot be provided by the
Reader Assistant
, source code for the
ArbSer
application (available upon request from [email protected]) is available.
ArbSer
is a terminal program with which you can communicate with the modules.
ArbSer
uses commands that are detailed in this document. See
.
This document is for developers and explains how to incorporate the Mercury5e (M5e) or
M5e-Compact product within a third-party host system.
Note
For an overview of the Developer’s Kit hardware and initial setup information
Appendix B: Getting Started - Devkit
Introduction
21
Product Line Overview
Product Line Overview
The embedded modules were designed to be incorporated into products requiring powerful RFID capabilities in a small form factor.
The M5e is a small form-factor, low power, low cost Gen2 module. The M5e is ideal for embedding a powerful RFID module with read and write capabilities into a product or system.
The M5e-Compact is a smaller version of the M5e. It has one MMCX connector for a monostatic antenna. The M5e-Compact is ideal for use in hand-held printers and other applications where size is the highest priority.
Product Specifications
The following table compares and contrasts the two Mercury embedded modules:
Comparison of features between M5e, and M5e-Compact
Item
Processor
Flash memory
On-chip RAM
RF Architecture
Input Power Requirements
M5e M5e-Compact
Atmel AT91SAM7S-256
256 kB
64 kB
ASIC Impinj Indy1000 with
ThingMagic front end for improved sensitivity
+5VDC +/-4%
7.5W max (6.5 typical)
25mV max peak-peak ripple no spectral spike greater than
5mVpp in any 1kHz band
Atmel AT91SAM7S-256
256 kB
64 kB
ASIC Impinj Indy1000 with
ThingMagic front end for improved sensitivity
+3 to +5.5VDC
2.7W max (2.6 typical)
25mV max peak-peak ripple no spectral spike greater than
5mVpp in any 1kHz band
Protocols supported
Dimensions:
Regions supported
GEN2, ISO 18000-6C
82mm L x 54mm W x 5mm H
NA, EU (3 variations), Korea,
India, China
GEN2, ISO 18000-6C
56mm L x 35.6mm W x 5mm H
NA, EU (3 variations), Korea, India,
China
22
Introduction
Hardware Overview
Electrostatic Discharge • IEC-61000-4-2 discharge direct to operational antenna port tolerates max 300 Volt Pulse
• MIL-883 3015.7 discharge direct to operational antenna port tolerates max 1200 Volt Pulse
Note: Survival level varies with antenna return loss and antenna characteristics. See
Appendix E: Environmental Considerations
for methods to increase ESD tolerances.
W A R N I N G !
The M5e antenna ports may be susceptible to damage from Electrostatic
Discharge (ESD). Equipment failure can result if the antenna or communication ports are subjected to ESD. Standard ESD precautions should be taken during installation and operation to avoid static discharge when handling or making connections to the M5e reader antenna or communication ports. Environmental analysis should also be performed to ensure static is not building up on and around the antennas, possibly causing discharges during operation.
Hardware Overview
The following sections explain the M5e and M5e-Compact hardware, and their hardware revisions.
Note
The M5e and M5e-Compact are the same except where specified that they are different.
M5e and M5e-Compact Hardware
The M5e and the M5e-Compact are single board modules designed for more spaceconstrained applications. The digital and analog electronics are on the same circuit board. They use a custom RFID reader chip or Application Specific Integrated Circuit
(ASIC).
Microcontroller
The M5e and M5e-Compact have Atmel ARM7 microcontrollers with 256 kB of on-chip flash memory for storage of all calibration and program data.
Introduction
23
Hardware Overview
RFID ASIC
All base-band analog circuitry and PLL circuitry are contained within the Impinj Indy1000
RFID ASIC with ThingMagic front end for improved sensitivity.
Connectors
The M5e supports two MMCX connectors for bistatic or monostatic antennas. The M5e-
Compact supports one MMCX connector for a monostatic antenna.
24
Introduction
Hardware Overview
Hardware Revisions
Table 2 lists the different Mercury Embedded hardware versions and their power output capabilities.
Mercury Embedded Hardware Versions
l
Module
M5e 1 Watt
M5e EU 1 Watt
Minimum Power
Out
5 dBm
5 dBm
M5e-Compact 0.2
Watt
10 dBm
Maximum Power
Out
30 dBm
30 dBm
23 dBm
Comments
Supports 1 Watt operation in NA and
KR regions and less than 0.2 Watt operation in EU and PRC regions in typical applications.
Supports 1 Watt operation in EU region.
Supports 0.2 Watt operation in all regions.
M5e/M5e-Compact Digital Connectors
The digital connector provides power, serial communications signals, and access to the
GPIO inputs and outputs.
M5e and M5e-Compact Connector
The communications interface for the M5e and M5e-Compact is a 12-pin digital connector. This connector provides power, serial communications signals, and access to the GPIO inputs and outputs. See the following table:
Introduction
25
SW Overview
Pin #
9
10
11
6
7
8
12
3
4
5
1
2
Signal
+5V
+5V
GND
GND
Digital Output 1
Digital Output 2
Digital Input 1
Digital Input 2
UART TTL RX from host
UART TTL TX to host
Mfg test purposes
Mfg test purposes
SW Overview
The software (SW) for the embedded products consists of two separate programs that coexist in flash memory:
The boot loader, which is started at power on, is not field upgradable. It is programmed into flash when the module is manufactured.
The application firmware, which implements the actual reader functionality, is field upgradable.
26
Introduction
SW Overview
Boot Loader
The boot loader provides low-level functionality. This program provides a customer interface for upgrading the application firmware and storing data into flash.
When a module is powered up or reset, the boot loader code is automatically copied from sector 0 of flash into the Microprocessor’s on-chip RAM, and executed. The boot loader provides the following features:
Ability to read / write / erase flash memory
Upgrade application FW
Change serial baud rate
Verify image CRC
Application Firmware
The application firmware (FW) is an important software component of the module. It contains the protocol code as well as all the user interfaces to set and get various system parameters. The application FW is started using the Boot Firmware command in the boot loader; it does not start by itself upon power up.
Note
You can use the Reader Assistant to upgrade the reader firmware through the bootloader.
Verifying Application FW Image CRC
The application FW has an image level Cyclic Redundancy Check (CRC) embedded in it to protect against corrupted firmware during an upgrade process. (If the upgrade is unsuccessful, the CRC will not match the contents in flash.) When the boot loader starts the application FW, it first verifies that the image CRC is correct. If this check fails, then the boot loader does not start the application FW.
The upgrade process uses a series of individual 250-byte packet write operations to ensure that an upgrade is successfully completed for the complete image. It also ensures that the application FW in flash was not corrupted accidently, and can be expected to perform properly when executed.
Introduction
27
28
SW Overview
About the Reader Assistant
An easy-to-use user interface (
Reader Assistant
) can be installed to simplify reader communication. This
Reader Assistant
can be used to demonstrate the embedded module or perform detailed evaluations of the product’s performance. The
Reader
Assistant
has the following features:
Real-time logging of all serial transmits and receives with a timestamp
Reading and writing of all tag commands
Debugging capability
Reading, writing, and modifying data stored in flash memory
Reading and writing to applications stored in flash memory
Updating of new firmware releases
Setting and getting parameters
Application Development
See
Appendix B: Getting Started
Introduction
Functionality of the Embedded
Modules
This section highlights some of the functionality of the modules. The details for using the serial commands to control this functionality are found in
.
Regional Support
The modules have differing levels of support for operation and use under the laws and guidelines of several regions. The regional support is shown in the following table.
Functionality of the Embedded Modules
29
Regional Support
30
Supported Regions
Region Regulatory Support M5e M5e-C M5e EU
North America (NA) FCC 47 CFG Ch. 1 Part 15
Industrie Canada RSS-210
European Union (EU) ETSI EN 302 208
ETSI EN 300 220 European Union
(EU2)
European Union
(EU3)
Korea (KR)
Revised ETSI EN 302 208
MIC
Korea (KR2)
India (IN)
KCC (2009)
Telecom Regulatory Authority of
India (TRAI), 2005 regulations
SRRC, MII
1
People’s Republic of
China (PRC)
Australia (AU)
New Zealand (NZ)
Open Region
ACMA LIPD Class Licence Variation 2011 (No. 1)
Radiocommunications Regulations (General User Radio
Licence for Short Range Devices)
Notice 2011
No regulatory compliance enforced
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
No
No
Yes
No
No
No
Yes
Note:
1- Under the current PRC regulations the module alone should berestricted to an output power setting of +21dBm or below. However, the exact maximum power setting is determined when the device in which the module is installed, and the module, is tested as a system.
The regional functionality is set using a single serial command,
.
Setting the Region configures the regional default settings including:
Loads the Frequency Hop Table with the appropriate table for the selected region.
Sets the PLL frequency to the first entry in the hop table, even if the RF is off.
Selects the transmit filter, if applicable.
Executes the Listen Before Talk (LBT) algorithm in supported regions, using the
defaults specified below or the user specified values when calling
.
Functionality of the Embedded Modules
Regional Support
Regions Supporting LBT - Default Settings
EU
EU3
Open
Region
Yes
No
No
LBT Enabled LBT Threshold
-96 dBm n/a
-96 dBm
Note
The Open Region allows the module to be manually configured within the full capabilities supported by the hardware. No regulatory limits, including: frequency range, channel spacing and transmit power limits, are enforced.
The Open Region should be used with caution.
!
C A U T I O N !
!
The EU2 Region does not implement LBT. Therefore, the limits in section
8.10 of the EN 300 220 specification, referring to duty cycle limits, apply.
Since the module does not enforce any duty cycle or power limitations when configured to use the EU2 region and will transmit 100% of the time during a tag operation it is the responsibility of the user to appropriately manage the RF duty cycle and power levels to conform with EN 300 220.
Functionality of the Embedded Modules
31
Frequency Setting
Frequency Setting
The modules have a PLL synthesizer that sets the modulation frequency to the desired value. Whenever the frequency is changed, the module must first power off the modulation, change the frequency, and then turn on the modulation again. Since this can take several milliseconds, it is possible that tags are powered off during a frequency hop.
In addition to setting the default regional settings, the modules have commands that allow the transmit frequency to be set manually.
!
C A U T I O N !
!
Use these commands with extreme caution.
It is possible to change the module’s compliance with the regional regulations.
Frequency Units
All frequencies in the Mercury embedded products are expressed in kHz using unsigned
32-bit integers. For instance, a carrier frequency of 915 MHz is expressed as 915000 kHz.
The PLL is set automatically to the closest frequency - based on the minimum frequency quantization for the current region - that matches the specified value. The Mercury embedded modules have an absolute minimum quantization of 25 kHz. Each region also has a minimum quantization based on regulatory specifications, which may be greater.
The following table details the frequency quantization in kHz for each region setting.
32
Functionality of the Embedded Modules
Frequency Setting
Regional Frequency Quantization
Region
EU3
KR
KR2
PRC
NA
EU
IN
EU2
AU
NZ
Open
Frequency
Quantization
250 kHz
100 kHz
100 kHz
50 kHz
100 kHz
25 kHz
25kHz
250 kHz
250kHz
250 kHz
25 kHz
Minimum
Frequency
902,000 kHz
865,100 kHz
865,200 kHz
869,000 kHz
865,600 kHz
910,000 kHz
917,300 kHz
920,125 kHz
920,750 kHz
922,250 kHz
860,000 kHz
Maximum
Frequency
928,000 kHz
867,900 kHz
866,800 kHz
869,850 kHz
867,600 kHz
914,000 kHz
920,300 kHz
924,875 kHz
925,250 kHz
927,250 kHz
960,000 kHz
When manually setting frequencies the module will round down for any value that is not an even multiple of the supported frequency quantization.
For example
: In the NA region, setting a frequency of 902,999 kHz results in a setting of 902,750 kHz.
When setting the frequency of the module, any frequencies outside of the valid range for the specified region are rejected.
Frequency Hop Table
The frequency hop table determines the frequencies used by the modules when transmitting. The hop table characteristics are:
Contains up to 62 slots.
Valid frequencies for the region currently selected.
Changes not stored in flash, thus changes made are not retained after a power cycle or a restart of the boot loader.
Inability to change individual entries after uploading without reloading the entire table.
Functionality of the Embedded Modules
33
34
Frequency Setting
Frequencies used in the order of entries in the table.
If necessary for a region, the hop table can be randomized to create a pseudo-random sequence of frequencies to use. This is done automatically using the default hop tables provided for each region.
EU3 Region
By default the frequency hop table for the EU3 region will use four channels. In addition to the default configuration the EU3 region can also be used in a single channel mode.
These two modes of operation are defined as:
Single Channel Mode
Set by manually setting the frequency hop table to a single frequency. In this mode the module will occupy the set channel for up to four seconds, after which it will be quiet for 100ms before transmitting on the same channel again.
Multi Channel Mode
Set by leaving the default or manually setting more than one frequency in the hop table. In this mode the module will occupy one of the configured channels for up to four seconds, after which it may switch to another channel and immediately occupy that channel for up to four seconds. This mode allows for continuous operation.
PRC Region
The PRC specifications limits channels 920 to 920.5MHz and 924.5 to 925.0MHz to transmitting at 100mW or below. The default hoptable on the Mercury5e and M5e-
Compact uses only the center channels which allow 2W ERP, 1W conducted, power output. If the hoptable is modified to use the outer, lower power channels the RF level will be limited to the outer channels limit, 100mW or +20dBm
KR2 Region
The first frequency channel (917,300kHz) of the KR2 region will be derated to +27dBm to meet the new Korea regulatory requirements. All other channels operate up to +30dBm.
In the worst case scenario, each time the derated channel is used it will stay on that channel for 400ms. The fastest it will move to the next channel, in the case where no tags are found using that frequency, it will move to the next channel after 10 empty query rounds, approximately 120ms.
Functionality of the Embedded Modules
RF Power Setting
RF Power Setting
The power setting is calibrated at the factory and parameters are stored in flash memory to ensure the power output is within +/– 1 dB of the desired setting. The power limits are set by both hardware limitations and enforced by the firmware.
Power Units
All power values are reported in centi-dBm. Therefore, a power setting of 2500 corresponds to 25 dBm. All power values in the serial interface are specified as unsigned
16-bit integers. A dBm means power referenced to 1mW. Therefore, the conversion from watts to dBm is: dBm = 10 log
10
(power in mW)
For example: 0.1W = 100mW = 20dBm and 1W = 1000mW = 30dBm.
Power Calibration
A power calibration event occurs when the Power set point is changed, the Frequency is changed, or the RF field is turned on. The power calibration routine calibrates the power within 10 ms.
Note
Power calibration only occurs once when the RF power is turned on. It does not occur periodically when the RF field is on.
This is not an issue during normal operation, since a frequency hop occurs at least every
400 ms and thermal drift does not affect the power level significantly. However, in CW waveform mode (Transmit CW Signal), no power calibration occurs unless the power or frequency is changed. Thus, it is possible to experience thermal drift in this usage if the unit is left to transmit continuously for a significant period of time.
TX Read Power
The TX read power is used for all non-write commands to tags. This may include, but is not limited to, commands to read a tag ID and read tag data.The TX Read Power can be set in two ways:
Functionality of the Embedded Modules
35
Antenna Ports
The default, module-wide, setting is specified using
setting is used for all read operations on all ports, except:
The power for individual logical antennas can be specified using
Set Antenna’s Power and Settling Time
. When a logical antennas power is set using that command it will override the module-wide setting for all read operations.
TX Write Power
The TX write power is used only during commands that change a tag’s state. This includes commands for Lock, Kill, as well as Tag ID Write and Tag Data Write.
Note
When performing write operations as part of
the TX Read Power will be used for those write operations, NOT the TX Write Power.
The TX Write Power can be set in two ways:
The default, module-wide, setting is specified using
. This setting is used for all write operations on all ports, except:
The power for individual logical antennas can be specified using
Set Antenna’s Power and Settling Time
. When a logical antennas power is set using that command it will override the module-wide setting for all write operations.
Note
During Write commands, which both write to and verify the written contents, the entire operation will be done at the Tx Write Power, including tag singulation and the write verify.
Antenna Ports
The modules have two antenna ports, except for the M5e-Compact which has one. While each port is capable of both transmitting and receiving, only one port can transmit or receive at a time. The antenna ports can be configured for either monostatic or bistatic
mode using the Set Antenna Port command
antenna port from the
Reader Assistant
Antenna Port menu
Configuring the Reader
.
In addition, the modules support
, allowing up to eight logical antenna
ports, controlled using the two GPOutput lines and the internal physical port J1/J2 switching.
36
Functionality of the Embedded Modules
Antenna Ports
Note
The M5e-Compact has one antenna port and only supports monostatic operation.
Monostatic Mode
To set up the module to use a single antenna in monostatic mode, connect the antenna to port 1 (labeled J1 on Printed Circuit Board) which is responsible for both TX and RX communication. If possible, terminate the unused port to prevent damage to the reader if it is accidentally commanded to transmit through it. The communication is configured using the Set Antenna Port command by setting both the TX and RX antenna ports to the same value.
To use two antennas in monostatic mode, connect one monostatic antenna to port 1 and the other antenna to port 2. With two monostatic antennas connected you can choose to manually select which antenna to use (based on the antenna set with Set Antenna Port) for tag operations or allow the module to search on both antennas automatically. Multiantenna Search can be specified by the Antenna Flag in the
command.
When using LBT, it will always be performed on antenna port 2 in monostatic mode. Due to this requirement you should always insure to have an antenna connected to port 2 when using a region with LBT enabled.
Bistatic Mode
In bistatic mode, antenna port 1 transmits data and antenna port 2 receives data. This requires either a two-port antenna, or two single-port antennas. This configuration provides better isolation between the transmitter and receiver, and should be used whenever possible.
Note
For bistatic mode, port 1 must be the TX antenna, and port 2 must be the RX antenna.
Using a Multiplexer
Multiplexer switching is controlled through the use of the internal module physical port J1/
J2 switch along with the use of one or both of the
General Purpose Inputs/Outputs (GPIO)
Functionality of the Embedded Modules
37
38
Antenna Ports
Output lines. In order to enable automatic multiplexer port switching the module must be configured to use
Use GPIO as Antenna Switch
.
Once the GPIO line usage has been enabled the following control line states are applied when the different Logical Antenna settings are used in
.
Note
The TX/RX Logical Antenna values are static labels indicating the available control line states. The specific physical antenna port they map to depends on the control line to antenna port map of the multiplexer in use. The translation from TX/RX Logical Antenna label to physical port must be maintained by the control software.
GPIO 1 & 2 Used for Antenna Switching
01 01
02 02
03 03
04 04
05 05
06 06
07 07
08 08
01 02
03 04
05 06
07 08
TX/RX Logical
Antenna Setting
High
High
High
High
Low
Low
High
High
Low
Low
Low
Low
GPIO
Output 1
State
Low
Low
High
High
Low
High
Low
High
Low
Low
High
High
GPIO
Output 2
State
Physical Module
Port State
TX=1 RX=1
TX=2 RX=2
TX=1 RX=1
TX=2 RX=2
TX=1 RX=1
TX=2 RX=2
TX=1 RX=1
TX=2 RX=2
TX=1 RX=2
TX=1 RX=2
TX=1 RX=2
TX=1 RX=2
Functionality of the Embedded Modules
Antenna Ports
Note
Just as under non-Multiplexing operation, Physical Module Port #1 must be used for transmitting and Port #2 for receiving when configured for bistatic operation.
If only one GPIO Output line is used for antenna control, the combinations of the available output control line states (the GPIO line in use and the module port) result in a subset of
TX/RX logical antenna settings which can be used:
ONLY GPIO 1 Used for Antenna Switching
01 01
02 02
05 05
06 06
01 02
05 06
TX/RX Logical
Antenna Setting
Low
Low
High
High
Low
High
GPIO
Output 1
State
Physical Module
Port State
TX=1 RX=1
TX=2 RX=2
TX=1 RX=1
TX=2 RX=2
TX=1 RX=2
TX=1 RX=2
ONLY GPIO 2 Used for Antenna Switching
01 01
02 02
03 03
04 04
01 02
03 04
TX/RX Logical
Antenna Setting
Low
Low
High
High
Low
High
GPIO
Output 2
State
Physical Module
Port State
TX=1 RX=1
TX=2 RX=2
TX=1 RX=1
TX=2 RX=2
TX=1 RX=2
TX=1 RX=2
Functionality of the Embedded Modules
39
Power Management
Power Management
The modules use different methods and levels of power management.
Power Modes
The M5e and M5e-Compact were designed for power efficiency and offer several different power management modes. The following lists the current modes being offered:
Full Power Mode – In this mode, the unit operates at full power to attain the best performance possible. This mode is only intended for use in cases where power consumption is not an issue. This is the default Power Mode at startup.
Minimal Saving Mode – This automatically executes basic power savings that do not severely degrade system performance May result in a nominal 1 ms additional delay on the M5e and 10 ms of delay on the M5e-Compact.
Medium Saving Mode – This mode may add up to 50 ms of delay on both the M5e and the M5e-Compact between commands. It performs more aggressive power savings, such as automatically shutting down the analog section between serial commands, and then restarting it whenever a tag command is issued.
Maximum Saving Mode – This mode essentially shuts down the digital and analog boards, except to power the bare minimum logic required to wake the processor. It can take up to 150 ms on the M5e and up to 100 ms on the M5e-Compact to wake the processor and execute the desired command.
Note
Maximum Saving Mode only supports communications at 9600 baud
Transmit Modes
The Transmit Modes (set through the
apply only to the M5e.
High Performance Mode
This mode maximizes performance without regard to thermal characteristics or power consumption. High performance mode consumes up to 7.5W (6.5 typical) of DC power at any RF setting. The is the default setting on the M5e.
40
Functionality of the Embedded Modules
Power Management
Low Power Mode
This mode minimizes power consumption and optimizes thermal characteristics without compromising performance in many, but not all, applications. Low power mode uses less
DC power than High Performance mode at all RF transmit levels. It consumes up to 7.5W
(6.5 typical) at a transmit level of +30dBm, decreasing to 3.5W at transmit levels of
+20dBm and below. Low Power mode should be selected for most applications, including:
All tag printer applications (where tags are placed very close to the antenna)
All applications where the Read and Write transmit power levels are between +27 and
+30 dBm.
If the application does not meet the above criteria, the optimum mode can be determined by considering a combination of conditions: expected transmit on/off duty cycle, expected ambient temperature, and whether the reader will be operating in a noisy RF environment.
The following table provides recommendations on which Power Mode to use for various application environments: printer, few readers (non-dense reader environment), many readers (dense reader environment); based on the required RF Power level.
Power Mode per Operational Environment and RF Power Setting
RF Transmit Power
Low Power Mode
5-18 dBm
• Printer
• Few Readers
18-27dBm
• Printer
27-30 dBm
• Printer
• Few Readers
• Many Readers
•
High Performance Mode
• Many Readers • Few Readers
• Many Readers
Thermal characteristics are another differentiator between the two modes. Low Power
Mode allows the module to operate in a 60 o
C ambient environment, regardless of how continuously the module is transmitting. High Performance mode is only recommended in a 60 o
C environment if the module is actively transmitting less than 50% of the time. If the module is transmitting more often than this, a lower maximum ambient temperature must be maintained as show in the following table:
Functionality of the Embedded Modules
41
Tag Buffer
Power Mode per Duty Cycle and Ambient Temperature
Transmit Duty Cycle
(% transmitting)
Low Power Mode
High Performance Mode
60 o
C
50% 75%
60 o
C 60 o
C
60 o
C 55 o
C 40 o
C
100%
Tag Buffer
The Tag buffer stores tags, and their metadata, found using the
command. The size of the tag buffer for each module is defined in the following table:
Tag Buffer Size
M5e
M5e-
Compact
200 Tag Buffer Size in Tag ID entries
200
Each tag entry consists of a fixed number of bytes. The size depends on the value set for
the Max EPC Length parameter in
. Each entry consists of the following fields:
42
Functionality of the Embedded Modules
Tag Buffer
Tag Buffer Entry
Total Entry
Size
18 bytes
(Max EPC
Length = 96bits)
Field
EPC
Length
PC Word
EPC
68 bytes
(Max EPC
Length = 496bits)
Tag CRC
EPC
Length
PC Word
EPC
Size Description
2 bytes Indicates the actual EPC length of the tag read. Cannot exceed the Max EPC length setting.
Contains the Protocol Control bits for the tag.
2 bytes
12 bytes Contains the tag’s EPC value padded with trailing zeros if the size is less than the Max
EPC Length size.
2 bytes
2 bytes
The tag’s CRC.
Indicates the actual EPC length of the tag read. Cannot exceed the Max EPC length setting.
2 bytes Contains the Protocol Control bits for the tag.
62 bytes Contains the tag’s EPC value padded with trailing zeros if the size is less than the Max
EPC Length size.
2 bytes The tag’s CRC.
Tag CRC
In addition to the tag EPC data each entry contains meta data about how, where and
when the tag was read. When using the
get the following tag meta data returned with each tag extracted from the tag buffer:
Functionality of the Embedded Modules
43
44
Tag Buffer
Tag Read Meta Data
Meta Data Field
Antenna ID
Read Count
Protocol ID
Timestamp
Tag Data
Description
The antenna on with the tag was read. If the same tag is read on more than one antenna there will be a tag buffer entry for
each antenna on which the tag was read. When Using a Multiplexer
, if appropriately configured, the Antenna ID entry will contain the logical antenna port of the tag read.
The number of times the tag was read on [Antenna ID].
Protocol of tag. Only 0x05 (Gen2) is supported.
The time the tag was read, relative to the time the command to read was issued, in milliseconds. If the Tag Read Meta Data is not retrieved from the Tag Buffer between read commands there will be no way to distinguish order of tags read with different read command invocations.
When
Data (28h) is called the Tag Buffer will contain up to 32 bytes
of data returned for each tag entry.
Note: Tags with the same TagID but different Tag Data can be considered unique and each get a Tag
By default it is not.
The frequency on which the tag was read
Reserved for Future Use - ThingMagic Only
The receive signal strength of the tag response.
Frequency
RFU
LQI/RSSI
Whenever a Tag entry is placed in the buffer, it uses up a single entry with the EPC section containing the
maximum EPC length
number of bits, regardless of the actual EPC size of the tag read. The extra bits in the entry are padded with trailing zeros.
After the Read Tag Multiple command finishes, it places all of the found tags into the Tag buffer, and then returns the number of tags found to the user. Only unique tags read on each antenna are added to the Tag buffer; none of the entries show repeated Tag EPCs, except when the same tag is read by both antennas, although repeated reads on an antenna will cause the Read Count field to be incremented for that tag entry. Multiple Get
Tag Buffer
commands must be sent to read out the Tags. The Tag buffer acts as a First
Functionality of the Embedded Modules
Tag Operations
In First Out (FIFO) — the first Tag found by the reader is the first one to be read out. See
.
The Tag buffer is reset when the
command is sent or when the protocol is set or changed using
Set Current Tag Protocol (93h)
. This allows multiple Read
Tag Multiple
commands to be used to acquire one consistent tag buffer set.
Tag Operations
In addition to inventorying tags the M5e supports commands, defined in
, which operate on individual tags in a variety of ways. The various operations
can be performed on the first tag to respond, the default behavior for all but
, as well as on all tags in the field as part of a
. Most of the operations can be performed with
allowing them to be applied to a specific tag or set of tags.
Custom Tag Commands
Many tags now support non-”Gen2 Standard” operations. Features such as read locking memory, setting digital outputs, reading sensor data - such as temperature - from sensor tags among many others. The supported commands are listed in the
MercuryAPI Programmers Guide | Level 2 | Advanced
Tag
Operations section.
Flash Memory
The modules have on-board flash memory. This flash is divided into four different sectors of varying sizes. Table 4 shows the memory map for the modules. Only sector 0x03 is set aside for user data and the other sectors are used by the application FW. For crossplatform and legacy development purposes two methods of accessing flash on the M5efamily modules is supported, one based on the memory map of the M4e. The memory map for the M4e is very different than the memory map for the M5e and M5e-Compact.
The flash sector utilities simplify the interface providing a means to develop interfaces that work across these platforms. For all new development you must use
Functionality of the Embedded Modules
45
Flash Memory
46
Flash Memory Sector Mapping
Sector Access
BootLoader
Application
Read Only
Read/Write
User Memory Read/Write
Hardware Info Read Only
0x01
0x02
0x03
0x04
Code
M5e/M5e-
Compact
Start Addr
0x000000
0x004000
0x03C000
0x002000
M5e/M5e-
Compact
Size
(bytes)
8 kB
224 kB
16 kB
8 kB
Accessing the Flash
The flash is accessed only through the boot loader program. Flash is not accessible while the application FW is running.
All accesses to flash are in terms of two-byte word addresses and word lengths. Thus, the Write Flash Sector,
Read Flash Sector
,
Erase Flash Sector
,
and Modify Flash
Sector
commands all use the same argument types. The maximum amount of flash that can be written or modified at a single time is 125 words, and the maximum amount of flash that can be read at a single time is 124 words. This is a limitation of the serial interface and data packet sizes. Multiple data packets are used to read/write/modify a larger area of flash.
When using the Erase Flash Sector or Write Flash Sector commands, the correct password must be provided to complete the operation. This is done to protect against accidentally erasing or writing to the flash. See
Upgrading Application FW
The application FW is upgraded in flash. New versions of firmware are released in a or
.sim binary file format for the M5e and M5e-Compact.The .sim binary file format is a compressed file format that stores the data in raw binary.
Direct Flash Addressing
The modules also provide a direct interface to the flash memory. This is a legacy interface and is not recommended for new development efforts.
Functionality of the Embedded Modules
Flash Memory
M4e Direct Flash Addressing
This interface divides the flash into 11 different sectors of varying sizes. Only whole sectors of flash can be erased at a time. However, any amount of flash can be written provided that it is currently blank. This interface should no longer be used,
Table 5 shows the memory map for the flash chip. Notice that only sector 9 is set aside for user data and the other sectors are used by the application FW.
Functionality of the Embedded Modules
47
48
Flash Memory
7
8
9
10
4
5
6
1
2
3
0
Sector
Word
Address
0x200000
0x208000
0x210000
0x218000
0x220000
0x228000
0x230000
0x238000
0x23C000
0x23D000
0x23E000
16
4
4
8
32
32
32
32
32
32
Flash memory map
32
Size
(kB)
--
Erase
Password
0x08959121
0x08959121
0x08959121
0x08959121
0x08959121
0x08959121
0x08959121
"
0x79138766
--
0x02254410
0x02254410
0x02254410
0x02254410
0x02254410
0x02254410
0x02254410
"
0x76346700
--
--
Write
Password
Comments
Boot loader area
Application FW
Application FW
Application FW
Application FW
Application FW
Application FW
Application FW
"
User Data
HW Calibration
Data
Note
Addresses and sizes are shown in words (16-bits).The erase and write passwords are not provided for sectors 0 and 10. These sectors are considered to be the system area, and cannot be modified.
M5e Flash Addressing
The M5e and M5e-Compact memory map uses virtual addressing which contrasts to M4e which has hard-coded addresses. The M5e/M5e-Compact also has a User Data sector which is 16 kilobytes. The M5e is backward compatible to the M4e so that anyone familiar with M4e can still use the same command to write to the User Data sector. The software converts the M4e command and data to the M5e command. However, the M4e has a limit of 8 kilobytes of User memory instead of the 16 kilobytes for M5e/M5e-Compact.
Therefore, it is preferable to use the Write Flash Sector command when writing user
data to the M5e/M5e-Compact flash memory
Functionality of the Embedded Modules
Serial Port
Serial Port
The modules communicate to a host processor via the TTL logic level UART serial port, accessed on the 12-pin digital connector for M5e/M5e-Compact. See
.
UART TTL Level TX
V-Low: Max 0.4 VDC
V-High: 2.9 to 3.3 VDC
8 mA max
UART TTL Level RX
V-Low: -0.3 to 0.8 VDC
V-High: 2 to 5.5 VDC
(Tied to 3.3 V through a pull-up resistor. Not harmful, but not recommended to drive the input above 3.3 V because then the input will be sourcing current to the 3.3 V supply.)
A level converter could be necessary to interface to other devices that use standard 12V
RS-232. Only three pins are required for serial communication (TX, RX, and GND).
Hardware handshaking is not supported. The serial port has an interrupt-driven FIFO that empties into a circular buffer.
The developer is responsible for ensuring that the host processor’s receiver has the capability to receive up to 256 bytes of data at a time without overflowing.
General Purpose Inputs/Outputs (GPIO)
The Mercury Embedded modules have four TTL level signals, two input lines and two output lines, available on the 12-pin (M5e/M5e-Compact) digital connector. These can be controlled via the Get User GPIO Inputs and Set User GPIO Outputs commands.
Note
the available GPIO Outputs will be reduced to 1
or 0 depending on whether one or both are used as control lines as specified
and
.
Functionality of the Embedded Modules
49
General Purpose Inputs/Outputs (GPIO)
M5e and M5e-Compact GPIOs
The M5e has two 3.3/5V serial input sensor ports (GPIO inputs) and two output indicator ports (GPIO outputs) of up to 24 mA. The M5e-Compact has two 3.3/5V GPIO inputs and two GPIO outputs of up to 8 mA.
50
Functionality of the Embedded Modules
Default Settings
Default Settings
Since default settings may change across release and be different across platforms we
None of the configurable settings in the application FW are saved in non-volatile memory.
Thus the system will always boot up in the same default state, regardless of how it was previously configured.
Functionality of the Embedded Modules
51
Default Settings
52
Functionality of the Embedded Modules
Overview of the Communication
Protocol
The serial communication between a computer (host) and the reader is based on a synchronized command-response/master-slave mechanism. Whenever the host sends a message to the reader, it cannot send another message until after it receives a response.
The reader never initiates a communication session; only the host initiates a communication session.
This protocol allows for each command to have its own timeout because some commands require more time to execute than others. The host manages retries, if necessary. The host keeps track of the state of the intended reader if it reissues a command.
Host-to-Reader Communication
Host-to-reader communication is packetized according to the following diagram. The reader can only accept one command at a time, and commands are executed serially, so the host waits for a reader-to-host response before issuing another host-to-reader command packet.
Header Data Length Command CRC-16 Checksum
Data
Hdr
1 byte
Len
1 byte
Cmd
1 byte
0 to N bytes
CRC Hi
I
CRC LO
2 bytes
Overview of the Communication Protocol
53
Host-to-Reader Communication
The fields are summarized in the following table.:
Field
Header (Hdr)
1
Data Length (Len)
Command
Data
CRC-16 Checksum
(CRC HI, CRC LO)
Length
1 byte
1 byte
1 byte
N
bytes
(0 to 250)
2 bytes
Description
Defines the start of the packet. Equal to 0xFF
Defines the length,
N
, of the data field contained in the packet.
Specifies the command that the reader is to execute.
Defines the binary data required by the reader for use with a command. This could, for example, represent transponder data to be written. The length,
N
, can vary between 0 and
250 bytes.
CRC-16 checksum (high order byte first). CRC polynomial is
CCITT CRC-16, with a preload of 0xFFFF. This does not fully
specify the operation of the CRC, see
1.Minimum packet length is 5 bytes; the maximum packet length is 255 bytes.
54
Overview of the Communication Protocol
Reader-to-Host Communication
Reader-to-Host Communication
The following diagram defines the format of the generic Response Packet sent from the reader to the host. The Response Packet is different in format from the Request Packet.
Header Data Length Command
Status Word
Data CRC-16 Checksum
Hdr
1 byte
Len
1 byte
Cmd
Status Word
1 byte
2 bytes
0 to
M bytes
CRC HI CRC LO
2 bytes
The fields are summarized in the following table.:
Field
Header (Hdr)
1
Data Length (Len)
Length
1 byte
1 byte
2
Command
3
Status Word
Data
1 byte
2 bytes
M
bytes
(0 to 248)
CRC-16 Checksum
(CRC HI, CRC LO)
2 bytes
Description
Defines the start of the packet. Equal to 0xFF
Defines the length,
M
, of the data field contained in the packet. Length can be 0 – 248 bytes
OpCode of the last command received
Specifies the status of the last command, Successful =
0x0000, else it contains a fault code.
Defines the binary data returned by the reader in response to a command. This could, for example, represent data read from a transponder. Data length,
M
, can be a minimum of 0 and a maximum of 248 bytes.
CRC-16 checksum (high order byte first). CRC polynomial is
CCITT CRC-16, with a preload of 0xFFFF. This does not fully
specify the operation of the CRC, see CCITT CRC-16 Calculation
.
Overview of the Communication Protocol
55
Reader-to-Host Communication
1.The minimum packet length is 7 bytes and the maximum packet length is 255 bytes.
2.Each host command receives a response from the reader. In the response packet, the Header, Data Length, Command, Data, and
Checksum are functionally similar to the command packet.
3.The only difference is the addition of the Status Word field. The Status Word has two types of values. A Status Word value of 0
(Zero) means the command received was successful. Any other value represents a fault.
CCITT CRC-16 Calculation
The same CRC calculation is performed on all serial communications between the host and the reader. The CRC is calculated on the Data Length, Command, Status Word, and
Data bytes. The header (SOH, 0xFF) is not included in the CRC.
A sample implementation of the CCITT CRC-16 algorithm is shown in this section. The
CRC_calcCrc8()
function is written to calculate the CRC one byte at a time, with the calculated value stored in crc_calc. The crc_calc value must be pre-loaded the first time the CRC_calcCrc8() function is called with 0xFFFF to initialize the calculated CRC. The final value of crc_calc is sent as the 16-bit CRC at the end of the message.
56
Overview of the Communication Protocol
Reader-to-Host Communication
An example implementation of CRC calculation, taken from the Arbser source CrcUtils.c, is shown here:
/** @fn void CRC_calcCrc8(u16 *crcReg, u16 poly, u16 u8Data)
* @ Standard CRC calculation on an 8-bit piece of data. To make it
* CCITT-16, use poly=0x1021 and an initial crcReg=0xFFFF.
*
* Note: This function allows one to call it repeatedly to continue
* calculating a CRC. Thus, the first time it's called, it
*
* should have an initial crcReg of 0xFFFF, after which it can be called with its own result.
*
* @param *crcRegPointer to current CRC register.
* @param poly Polynomial to apply.
* @param u8Datau8 data to perform CRC on.
* @return None.
*/ void CRC_calcCrc8(u16 *crcReg, u16 poly, u16 u8Data)
{ u16 i; u16 xorFlag; u16 bit; u16 dcdBitMask = 0x80; for (i=0; i<8; i++)
{
// Get the carry bit. This determines if the polynomial should be
// xor'd with the CRC register.
xorFlag = *crcReg & 0x8000;
// Shift the bits over by one.
*crcReg <<= 1;
// Shift in the next bit in the data byte bit = ((u8Data & dcdBitMask) == dcdBitMask);
*crcReg |= bit;
// XOR the polynomial if (xorFlag)
{
*crcReg = *crcReg ^ poly;
}
// Shift over the dcd mask dcdBitMask >>= 1;
}
}
Overview of the Communication Protocol
57
Format for Microprocessor Reply to Host
Format for Microprocessor Reply to Host
There are three different types of replies that the microprocessor can make to the host as follows:
Acknowledge that the command was properly processed (ACK)
Return a fault code
Provide data that is requested by the host
This section describes each of these three types.
Unless otherwise specified, all commands return, as part of the Reply message, a status word with an ACK or a Fault. Those commands that return a Data Reply message are clearly shown.
Microprocessor ACK Message
Many of the commands require the microprocessor to perform a function, but do not require the microprocessor to send data back to the host. However, since the host cannot send a message until the microprocessor replies, an ACK is sent.
The ACK message contains no data. It returns the same OpCode that was sent originally to the microprocessor, sets the Status Word to 0x0000 (zero) and the Data Length to
0x00 (zero).
58
Overview of the Communication Protocol
Format for Microprocessor Reply to Host
The following shows an example of an ACK message to an Erase Flash command.
FF
SOH
00
Length
07
OpCode
00
Status
00 F4
CRC
27
The value in the OpCode field (0x07) is the same as the Erase Flash OpCode, 0x07.
Microprocessor Fault Reply Message
If a problem occurs during the execution of a command, the microprocessor returns a non-zero status value. Although this usually implies a fault or error, sometimes the nonzero status simply indicates a condition of the system. For instance, when executing a
Read Tag Single
command, if no tags are found, a status code of 0x0400 is returned. An example of a fault reply message is shown for the Erase Flash command.
FF
SOH
00
Length
07
OpCode
02
Status
00 F6
CRC
27
A list of error codes is included in
. Refer to this list when encountering any non-zero status codes.
Microprocessor Data Reply Message
If the requested command requires that the microprocessor returns data, then the microprocessor creates a message similar to the Microprocessor ACK Message with the data length set to a non-zero value. Since this command does not require a data field, the length field is set to Zero.
FF
SOH
00
Length
07
OpCode
00
Status
00 F4
CRC
27
Overview of the Communication Protocol
59
Format for Microprocessor Reply to Host
Here is an example of a Reply message with Data Field Length not zero. This message happens to be a successful reply to Read Tag Single command.
FF
SOH
0A
Length
21
OpCode
00
Status
00 C8 05 07 A8
Tag ID
00 84 C4 FF 9E E0
Tag CRC
F7
CRC
25
60
Overview of the Communication Protocol
Command Set
The following list defines the OpCodes that are used in the embedded modules firmware.
As these products grow, more OpCodes will be added to enhance the functionality of the product. The timeout for the commands are in milliseconds. The maximum value for any user-configurable timeout is 65,535msec (0xFFFF), unless otherwise noted. The
OpCodes are divided into five categories:
0x00 – 0x1F
0x20 – 0x5F
0x60 – 0x8F
Note
See
Minimum Set of Serial Commands
for the minimum startup command sequence required to configure the module and read tags.
Command Set
61
Format for Microprocessor Reply to Host
Format for Microprocessor Reply to Host
There are three different types of replies that the microprocessor can make to the host as follows:
Acknowledge that the command was properly processed (ACK)
Return a fault code
Provide data that is requested by the host
This section describes each of these three types.
Unless otherwise specified, all commands return, as part of the Reply message, a status word with an ACK or a Fault. Those commands that return a Data Reply message are clearly shown.
Microprocessor ACK Message
Many of the commands require the microprocessor to perform a function, but do not require the microprocessor to send data back to the host. However, since the host cannot send a message until the microprocessor replies, an ACK is sent.
The ACK message contains no data. It returns the same OpCode that was sent originally to the microprocessor, sets the Status Word to 0x0000 (zero) and the Data Length to
0x00 (zero).
62
Command Set
Format for Microprocessor Reply to Host
The following shows an example of an ACK message to an Erase Flash command.
FF
SOH
00
Length
07
OpCode
00
Status
00 F4
CRC
27
The value in the OpCode field (0x07) is the same as the Erase Flash OpCode, 0x07.
Microprocessor Fault Reply Message
If a problem occurs during the execution of a command, the microprocessor returns a non-zero status value. Although this usually implies a fault or error, sometimes the nonzero status simply indicates a condition of the system. For instance, when executing a
Read Tag Single
command, if no tags are found, a status code of 0x0400 is returned. An example of a fault reply message is shown for the Erase Flash command.
FF
SOH
00
Length
07
OpCode
02
Status
00 F6
CRC
27
A list of error codes is included in
. Refer to this list when encountering any non-zero status codes.
Microprocessor Data Reply Message
If the requested command requires that the microprocessor returns data, then the microprocessor creates a message similar to the Microprocessor ACK Message with the data length set to a non-zero value. Since this command does not require a data field, the length field is set to Zero.
FF
SOH
00
Length
07
OpCode
00
Status
00 F4
CRC
27
Command Set
63
Boot Loader Commands
Here is an example of a Reply message with Data Field Length not zero. This message happens to be a successful reply to Read Tag Single command.
FF
SOH
0A
Length
21
OpCode
00
Status
00 C8 05 07 A8
Tag ID
00 84 C4 FF 9E E0
Tag CRC
F7
CRC
25
Boot Loader Commands
The BootLoader is automatically started upon power up, and allows access to the onboard flash memory along with other commands. The program exits only when the Boot
Firmware
command is received. Once that occurs, the firmware image starts executing and sends back a reply to the Boot Firmware command. The BootLoader can also be started using command 0x09, Start BootLoader.
With the M5e/M5e-Compact, ThingMagic has created a hardware-neutral version of the bootloader. The reason for this change was that the M4e modules had an interface that was not easily portable to future modules. The M5e and M5e-Compact use an abstract version of these commands to provide easy inter operability between modules. The affected commands are:
0x01 – Write flash by address. Will be deprecated in future releases, replaced by
0x0D.
0x02 – Read flash memory. Will be deprecated to no longer accept 6 arguments.
0x06 – Set baud rate. Will be deprecated to only accept u32 baud rates.
0x0A – Modify flash. Will be deprecated in future releases, replaced by 0x0F.
0x0D – Write flash by sector.
0x0E – Get sector size.
0x0F – Modify flash by sector.
It is recommended to use the new interface wherever possible, since future products will no longer support the old ones as noted above. The M5e/M5e-Compact support most of the old interfaces (to ease transition for existing users) but support is not 100% guaranteed.
64
Command Set
Boot Loader Commands
The following table shows which commands are supported by the Boot loader, the application, and the modules.
Boot Loader Commands
0x0C
0x0D
0x0E
0x0F
0x04
0x06
0x08
0x09
OpCode
0x02
0x03
Command Name
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Bootloader
N
N
App
Firmware
N
N
Y
N
N
N
N
Y
Command Set
65
Boot Loader Commands
Read Flash (02h)
The Read Flash command reads the contents of flash from the specified address. Since the length of the Microprocessor reply packet is limited to 248 bytes, reading the application firmware data requires multiple read commands.
Note
Length is defined as the number of 16-bit words, and the maximum value of length is 124 words.
M5e/M5e-Compact Flash Read Example
There is an option where the M5e/M5e-Compact can read flash by sector number to decouple the memory map from the serial interface. From now on, all embedded products will use this interface.
FF
SOH
06
Length
02
OpCode
00 00 00
Start Address
00 02
Sector
05
Num Bytes To Read
FA
CRC
59
In this example, the sector number 02 indicates the application area. This command reads the first five data elements of the application, which is equivalent to the original command (using data length of 05). The sector codes can be found in
The reply to this command looks like this
:
FF 0A 02 00 00 01 23 45 67 89 AB CD EF 01 23
SOH Length OpCode Status 1
Word 1
2
Word 2
Word 3 Word 4 Word 5
1.
Word 1 contains the data located at address 0x208000
.
2.Word 2 contains the data at address 0x208001, and so forth. (Remember that the Microprocessor data is word addressed.)
BC
CRC
ED
Error Status Codes
FAULT_FLASH_ILLEGAL_SECTOR – 303h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
66
Command Set
Boot Loader Commands
Get Boot Loader/Firmware Version (03h)
The Get Boot Loader command returns the Boot Loader, Hardware, and Application version numbers. The Boot Loader, Hardware, and Application FW version numbers are stored in flash. The Boot Loader and Hardware version numbers are each 32-bit numbers. The application has a 96-bit version code. The command to retrieve firmware version is shown in the following table.
FF
SOH
00
Length
03
OpCode
1D
CRC
0C
M5e-Compact and M5e Command Responses
A sample response for the M5e-Compact to the command is shown in the following table:
FF
SO
H
14
Length
03
OpCod e
00 00
Status
07 09 17
BootLoader Ver
00 01 00 00
Hardware Ver
01 20 07
Firmware Date
10 12 09 05 12
Firmware Version
00
00 00 00
Supported Protocols
10 6B
CRC
CC
The following information is embedded in the reply to the command:
The boot loader version is 07.09.17.00. This number is in hex format.
HW Version is 01000001. For a definition, see
.
The application firmware was compiled on 2007-October-12.
The application firmware version is 09.05.12.00. This number is in hex format.
The protocol supported by this firmware – Gen2 and ISO 18000-6C.
A sample response for the M5e to the command is shown in the following table:
FF
SO
H
14
Length
03
OpCod e
00 00
Status
07 09 06
BootLoader Ver
00 00 00 00
Hardware Ver
03 20 07
Firmware Date
10 04 09 05 12
Firmware Version
00
00 00 00
Supported Protocols
10 AD
CRC
6E
Command Set
67
Boot Loader Commands
Returned Hardware Version Table
The following table provides a definition of each HW version returned by the Get Boot
Loader
/Firmware Version command.
Returned HW Versions
Module Defined
HW_VERID_0_5W
HW_VERID_1_0W_NON_ROHS
M4e
M5e
HW_VERID_1_0W_ROHS_EXT
HW_VERID_1_0W_NON_ROHS_E
XT
0x03010000
HW_VERID_1_0W
M5e EU HW_VERSION_M5E_EU_REV_1
M5e-
Compact
HW_VERID_0_2W_COMPACT
Version
0xFFFFFFFF
0x01010000
0x03020000
0x00000001
0x00000002
0x00000003
0x02000001
0x01000001
0x01000003
Description
0.5 W original non-RoHS compliant curve (downward slope) and power range
20-30 dBm
RoHS compliant curve (upward slope) and power range 5-30 dBm original non-RoHS compliant curve (upward slope) and power range 5-30 dBm
1W, small form-factor, Impinj
Indy1000 ASIC; Pre-production hardware, contact [email protected].
Noise improvements
Adds LBT and DRM
Provides full 1 Watt power in EU region.
0.2 W, compact size, Impinj
Indy1000 ASIC; Supports up to firmware version 1.0.22.
Supports reduced power consumption
If the Get Boot Loader/Firmware Version command returns a different value than those listed in the table, you should contact [email protected]
.
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
68
Command Set
Boot Loader Commands
Boot Firmware (04h)
The Boot Firmware command tells the boot loader to run the current firmware image stored in flash in the following sequence:
1.
The boot loader verifies the checksum of the application image before it is run.
2.
If the image is invalid, a fault code is returned to the host.
3.
If the application firmware is started successfully, it sends the response to the Boot
Firmware
command.
The response is identical to the response to a Get Version command, except that the OpCode is 0x04 instead of 0x03.
Note
The maximum time required to boot the application firmware is 650ms.
There will be release to release variation in actual boot time but it will always be less than the maximum.
Error Status Codes
FAULT_BL_INVALID_IMAGE_CRC – 200h
Set Baud Rate (06h)
The Set Baud Rate command has a default baud rate of 9600 bps. Since the code method of specifying the baud rate is processor dependent, a new interface was created to make the modules easily interchangeable.
The following table shows the hexadecimal equivalent for each baud rate:
Baud Rate (decimal)
9600
19200
38400
57600
115200
230400
Baud Rate (hex)
0x00002580
0x00004B00
0x00009600
0x0000E100
0x0001C200
0x00038400
Command Set
69
Boot Loader Commands
70
4608001
0x00070800
9216001
0x000E1000
Note:
1 - 460800 and 921600 cannot be used in bootloader mode, only application mode.
!
C A U T I O N !
!
When using the 921600 baud rate you must pass an extra byte of data
(0x00) at the end of each message, after the CRC. This is due to a timing issue. If the extra byte is not passed the message will not be processed until the another byte of data is received.
In the following example, the baud rate is specified as a 32-bit value. This example sets the baud rate to 115200:
FF
SOH
04
Length
06
OpCode
00 01 C2
Baud Rate
00 A4
CRC
60
The response to baud rate change is sent at the baud rate that the Set Baud Rate command was transmitted. Once the baud rate has changed, the new rate is in effect until the baud rate is changed by power cycling the reader.
Note
The baud rate reverts back to 9600 bps at power-up.
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_INVALID_BAUD_RATE - 10Ah
Verify Image CRC (08h)
After uploading a new application firmware image, the application CRC can be checked with the Verify Image CRC command. The application CRC is already embedded in the firmware image, so this command calculates the firmware’s CRC in flash and compares it to the pre-stored value. It returns a fault code if the application firmware fails the CRC
Command Set
Boot Loader Commands checks. A failed CRC means that the application cannot run, and needs to be downloaded again.
FF
SOH
00
Length
08
OpCode
1D
CRC
07
The boot loader runs this command automatically before loading the application. If the
CRC check fails, the boot loader does not run the application to prevent corrupted code from executing on the Microprocessor.
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_BL_INVALID_IMAGE_CRC – 200h
Start Bootloader (09h)
The Start Bootloader command shuts off the analog board and starts the boot loader while inside the application. This is necessary to perform an upgrade of the firmware while the system is running.
FF
SOH
00
Length
09
OpCode
1D
CRC
06
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
Command Set
71
Boot Loader Commands
Get Current Program (0Ch)
The Get Current Program command returns a code for the current program being executed in the module. These codes are defined as follows:
0x11
0x12
Code Program
M5e/M5e-C Bootloader
M5e/M5e-C Application
To get the current program command, send the following to the module:
FF
SOH
00
Length
0C
OpCode
1D
CRC
03
The module responds as follows, indicating that it is a M5e/M5e-Compact application program:
FF
SOH
01
Length
0C
OpCode
00
Status
00 12
Program
63
CRC
43
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
Write Flash Sector (0Dh)
The Write Flash Sector command is the same as the old Write Flash (01h) except it has an extra flash sector argument. This allows future Mercury Embedded products to work with the same command set.
FF
SOH
0F
Lengt h
0D
OpCod e
02 25 44
Password
10 00 00 00
Start Address
00 02
Sector
12 34 56 78
Data To Write
90 12 73
CRC
4C
72
Command Set
Boot Loader Commands
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_FLASH_ILLEGAL_SECTOR – 303h
FAULT_FLASH_BAD_WRITE_PASSWORD – 301h
Get Sector Size (0Eh)
The size of a flash sector can be retrieved from the module using the Get Sector Size command. Since different products may have different flash sector sizes, this command is useful for ensuring that the module has enough memory to store the desired data. This example receives the sector size for the application area:
FF
SOH
01
Length
OE
OpCode
02
Sector
D1
CRC
The response to this command on M5e is shown in the following example:
BF
FF
SOH
04
Length
OE
OpCode
00 00
Status
00 03 40
Size of Sector
00 88
CRC
54
The size of the sector is returned in bytes. For M5e, sector 2 (application) is 212992 bytes.
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_FLASH_ILLEGAL_SECTOR – 303h
Modify Flash Sector (0Fh)
The Modify Flash Sector command is the new version of the original Modify Flash
(0Ah) command. The following example writes 6 bytes to Sector 03.
FF 0F 0F
SOH Length OpCode
79 13 87
Password
66 00 00 00 00
Start Address
03
Sector
12 34 56 78
Data To Write
90 12 4C
CRC
FA
Command Set
73
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_FLASH_ILLEGAL_SECTOR – 303h
FAULT_FLASH_BAD_ERASE_PASSWORD – 300h
Boot Loader Commands
74
Command Set
Application Tag Commands
Application Tag Commands
The application commands are used to interact with RFID tags in the field. These commands can have slightly different behavior based upon the current protocol selected in the system.
Applications Commands
OpCode
0x21
0x22
0x23
0x24
0x25
0x26
0x28
0x29
0x2A
0x2D
0x2E
Command Name
N
N
N
N
N
N
N
N
N
N
N
Bootloader
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
App
Firmware
Tag Singulation/Select Functionality
Many of the Gen2 tag commands now support the ability to singulate a specific tag or inventory only tags matching a defined criteria, i.e. matching on values in the EPC, TID and User Memory banks.
Select Algorithm and Parameters
The algorithm used to perform a Gen2 Select and its impact on subsequent Gen2 Query operations on a population of tags is determined by several user defined settings which either correspond directly to or are used to determine the various Gen2 Select and Query
Command Set
75
76
Application Tag Commands parameters as defined by the EPCGlobal Gen2 v1.2 Specification. The current user controlled options are:
Gen2 Session (User Controlled)
This setting determines which tag inventory flag is altered when a tag responds to a Gen2
Query (each flag has a unique persistence profile, as defined by the Gen2 Specification).
The value of Gen2 Session and Gen2 Target is set using the
command.
Select Invert (User Controlled)
This setting is used to determine the Gen2 Action value sent in the Gen2 Select command. The value of Select Invert is defined using bit 3 of the Select Option field in the
0
(False) - Tags which match the Select criteria are to respond. Set Gen2
Action=0.
1
(True) - Tags which DO NOT match the Select criteria are to respond. Set Gen2
Action=4.
The settings specified for Gen2 Session and Select Invert determine the settings within the Select command which is sent before the corresponding Gen2 Query and the settings in the subsequent Gen2 Query(s). These implicit settings used by the Gen2 Select are:
Gen2 Action (defined by Select Invert)
This parameter can be one of 8 values, as defined by the Gen2 specification, which determine which of 4 possible flag actions (assert, de-assert, negate, or leave alone) will be done if the criteria matches and, similarly, which of the 4 possible flag actions will be done if the criteria does not match. Only two values are currently used:
0
- Assert (or put in state “A” for inventory flags) the target flag if there IS a match; de-assert (or put in state “B” for inventory flags) the target flag if there IS
NOT a match.
4
- Assert (or put in state “A” for inventory flags) the target flag if there IS NOT a match; de-assert (or put in state “B” for inventory flags) the target flag if there IS a match
Command Set
Application Tag Commands
Gen2 Target (User Controlled)
This setting determines which inventory flag or SL flag is going to have its state determined by the matching algorithm. Currently always set to ‘4’, indicating the Gen2
Select command modifies a tag’s SL flag.
The following table defines the currently supported User Settings and the resulting behavior of the Gen2 Select and Gen2 Query:
Gen2 Select and Query Behavior
User Settings Select Behavior
• Gen2 Session =
0,1,2,3
• Invert = 0
• Gen2 Target = A,
B, A<>B, B<>A
• Gen2 Session =
0,1,2,3
• Invert = 1
• Gen2 Target = A,
B, A<>B, B<>A
Gen2 Select Settings:
• Target = 4
• Action = 0
If tags match the criteria, put their SL flag in the ‘Assert’ state; and SL of non-matching tags into the ‘De-assert’ state.
Gen2 Select Settings:
• Target = 4
• Action = 4
If tags match the criteria, put their SL flag in the ‘De-assert’ state; and SL of non-matching tages into the ‘Assert’ state.
Query Behavior Comments
Gen2 Query Settings:
• SEL = 3
• Target = [User Defined]
• Session = [User Defined]
Ask tags to respond if their SL flag is in the ‘Assert’ state and their session appropriate inventory flag is in the user defined state (default is ‘A’). Once a tag responds, it puts the inventory flag in the opposite state
(default is ‘B’), preventing further matches until the inventory
changes it back.
Tag state persistence before a Query is based on SL flag persistence;
Tag state persistence after a Query is based on inventory flag corresponding to the Session used.
Select Process
The following defines how the Select process works when attempting to select tags that match a defined criteria:
1.
The Reader issues a Select containing the desired tag memory values and instructions for the tag to assert if its contents matches that specified in the request
(and, conversely, de-assert the SL flag if it does not match) as defined by the
. The de-assert will generally have no effect because the deasserted state is the default, but is helpful if tags still have their SL flag asserted from a previous Select.
– Tags that are selected, at this point, are not selected within a specific Session. The persistence of their state depends entirely on that of the SL flag.
2.
A Query is issued which specifies the flag settings which must match before a tag will respond:
Command Set
77
Application Tag Commands
78
– The SL flag must be asserted
– The Session flag (Target setting) for session 0, 1, 2, or 3 (specific Session value is in the Query and depends on the reader’s Session setting) must be in the user defined state (the default value is ‘A’).
3.
Matching tags will respond to the Query, but after responding, will change their own state in the following way:
– The Inventory flag corresponding to the Session specified in the Query will be changed to the opposite state (A->B or B->A).
– The SL flag will remain asserted (per its ongoing
)
4.
If subsequent indentical Queries are issued (identical to the first), this tag will remain silent until the
for the inventory flag that was put into the ‘B’ state cause the flag to fall back into the ‘A’ state or vice-versa. At that point, the tag will respond again (assuming that the persistence rules of the SL flag are still keeping it in the ‘assert’ state). Unless the Target Value was set to search for A then B or B then A, in which case tags will be re-inventoried when the reader changes the flag value its searching for instead of waiting for the tag to put its tag back into the opposite state.
Note
A search with Invert=1 specified will perform the same steps except in step
1 the tag will “de-assert if its contents matches that specified in the request
(and, conversely, assert the SL flag if it does not match) as defined by the
Note
A Select will be performed once per antenna when Select is specified during
with multiple antennas configured.
Flag Persistence Rules
Session 0
Keeps state as long as tag is energized
Returns to default state as soon as the tag is no longer energized
Its state will often get reset during the course of executing a single command, for example, between inventory rounds, or when there is a frequency hop, or when a new antenna is selected during a Read Tag Multiple search. the result is that when the session is set to ‘0’, all tags will respond to every appropriate Query, considerably lengthening the time to inventory a large population of tags. Session 0 is typically used for operations where a single tag is expected to be in the field, for example, printers.
Command Set
Application Tag Commands
Session 1
Keeps its state between 0.5 and 5 seconds, regardless of whether the tag is energized or not.
The intent is that when the session is set to 1 the tag will respond to an appropriate Query immediately, and then respond periodically if the Query is repeated by the reader. This allows a larger population of tags to be reliable read. Session 1 is typically used in applications where a large population of tags is being continuously inventoried allowing for it to be determined when tags enter and leave the field.
Session 2, 3 and SL Flags
Keeps state as long as the tag is energized.
Keeps its state for at least 2 seconds after the tag is no longer energized and will refresh its state if the tag is re-energized during that period.
The intent is that when the session is set to ‘2’ or ‘3’ a tag will only respond once to an appropriate Query, then remain silent as the Query is repeated by the reader to elicit responses from other tags. Typically used in operations when you are performing an action on tag or population of tags which you do not want/need repeated.
Operations supporting Tag Singulation/Select
The commands currently supporting tag singulation through Select are:
The addition of this functionality has added several (some conditional) fields to these commands. The deprecated version of these commands are listed in Appendix D:
Command Set
79
Application Tag Commands
. The command information in this section has been updated to
only
include the new format.
The following fields have been added to all the specified commands. Please check each command for exact order, and any exceptions, as they may not all correspond with the order below.
Field
Select Options
1
Select
Contents
(Bits 0,1, 2)
1
Select
Invert
(Bit 3)
1
Extended
Select Data
(Bit 5)
0x00
0x01
0x02
0x03
0x04
0x05
0x08
Tag Singulation Fields
Values Description
Select functionality is disabled. First tag found will be the tag operated on. No other Tag Singulation Fields should be specified. Option field must always be specified.
Note:
When Select is disabled commands do not support an access password. Use Select Option=0x05 to send a password without Select.
Select on the value of the EPC. Requires all fields except the
Select Address
field.
Select on contents of TID memory bank (Gen2 bank 0x02).
Requires all fields.
Select on contents of User Memory memory bank (Gen2 bank 0x03). Requires all fields.
Select on contents of the EPC memory bank (Gen2 bank
0x01). Requires all fields.
Use this option when you need to specify an access password to operation on locked data but don’t want to perform a
Select. When this option is used do not pass any Select Criteria.
Sets Invert Flag. This results in tags NOT matching the specified Tag Singulation Fields will be returned, as defined
in Select Algorithm and Parameters
.
0x20 Changes
Select Data Length
to 2 bytes, allowing
Select
Data
to be greater than 255 bits.
80
Command Set
Application Tag Commands
Field Values Description
The Select Options field is typically followed by command specific fields. After the command specific fields the following Tag Singulation fields should be specified as appropriate for the Select Contents specified.
Select Address 4 bytes
Select Data Length 1 byte
(
2 bytes if Extended
Data enabled
)
Contains the offset, in bits, within the memory bank, specified by the
Option
value, at which the comparison is to start.
NOTE: specifying
Option=0x04
and
Select Address=0x20
is the equivalent, for Gen2 v1 tags, of specifying
Option=0x01
, both specify a comparison against the tag EPC ID data.
Note:
Addresses are always zero-based. Specifying 0x00 indicates starting at the first address location.
Contains the length of the data (
Select Data
) to be compared, in bits, to the EPC when
Option
=0x01, or to the data beginning at
Select Address
for other options.
Select Data M bytes Contains the data to be compared against the specified tag data (memory bank and address, or EPC as specified by the
Option
value)
The bit values used start at address 0. So if
Select Data
Length = 2
, i.e. matching 2 bits, then the bits used for comparision will be the 2 most significant bits of the
Select Data
value. Examples:
Select Data = 0x00 the bits to match will be 0, 0
Select Data = 0x8F the bits to match will be 1, 0
This is independent of the
Select Data Address
field.
Note:
1- The Select Options field contains multiple sub fields which must be combined into a single Select Options value. This means the final Select Options value is a result of Select Invert + Select Contents.
Example:
The following EPC IDs (first 3 bits) are in the field:
0xAAAA (101)
0xCCCC (110)
0x4444 (010)
0x3000 (001)
Select Option
= 0x04 (EPC Mem Bank)
Select Data Length
= 0x01 (1 bit)
Select Data
= 0x80
Select Data Address
= 0x00000022 (third bit in the EPC ID)
In this case the third bit of the EPC ID is matched against the first bit of the
Select
Data
value, 1. This would result in the following IDs being returned:
0xAAAA
0x3000
Command Set
81
Application Tag Commands
Gen2 Memory Map
When performing a Tag Singulation/Select most of the criteria specifies values of data in certain locations in a Gen2 tag’s memory map. The following is a logical view of the Gen2 memory map from the Generation2 Protocol v1.2 that can be used for reference when trying to determine the memory address you are trying to match on:
Gen2 Tag Memory Map
82
Note
The address values specified in the memory map are hexidecimal, zerobased bit offset within each memory bank (i.e. the PC section of the EPC memory bank starts at bit 0x10, decimal 16, and runs to bit 0x1F, decimal
31). It is important to note the units used in various command fields for address locations. In some cases the address is specified in words (16 bit chunks), sometimes bytes (8 bit chunks) and sometimes bits.
Command Set
Application Tag Commands
Read Tag Single (21h)
For deprecated version (including non-Gen2 protocol specific syntax) of this command
The Read Tag Single command will search for a tag for the specified timeout or a single
tag is found, whichever comes first. The search criteria is specified using the
. If Option=0x00 is specified it will return with the first tag it finds,
otherwise it will only return Success and the found EPC if a tag matching the specified criteria is found. If no tag is read, a fault code is returned.
In addition to the Tag Singulation Fields the basic Read Tag Single command takes a 16bit timeout value in milliseconds. The command will return after a tag is found or the timeout expires, whichever happens first.
The basic syntax which returns only the tag EPC is defined in
additional Option bits set Read Tag Single can also return
.
Note
Read Tag Single will always use Gen2 Q=0 when
set to Dynamic Q. For use with large tag populations a Static Q
appropriate for the population should be used to avoid collisions.
Get Tag EPC
The following example shows a search requesting a tag matching the following criteria for a max timeout of 1000 ms. This example uses the
Tag Singulation/Select Functionality
with
Option=0x03, indicating Tag Selection based on the contents of User Memory, specifically:
Memory Bank = User Memory.
Starting Address = bit 32
Select Data = 0x1234
Command Set
83
84
Application Tag Commands
FF
SOH
0A
Length
21
OpCode
03 E8
Timeout (ms)
03
Option
00 00 00
Select Address
20 10
Select
Data
Length
12 34
Select Data
E5
CRC
AC
If Option=0x00 or 0x01 were used then the unused
removed from the request.
The response to this command varies depending upon the number of bits in the tag EPC of the tag found. The general response format is shown here:
FF
SOH
M+3
Length
21
OpCode
00 00
Status
03
Option
M bytes
EPC
??
??
??
??
TagCRC CRC
Get Tag EPC and Meta Data
In addition to getting the tag EPC value returned you can also get
the found tag. This version of Read Tag Single requires bit 4 of the Option flag to be set and takes an additional Metadata Flags field which defines what metadata will be returned The following table lists the supported values for these fields.
Command Set
Application Tag Commands
Read Tag Single Get EPC and Metadata Request Fields
Field Value Description
Option
Metadata Flags
(to specify more than one OR the values together)
Bit 4=0
(0x0X)
Bit 4=1
(0x1X)
0x0000
0x0001
0x0002
0x0004
0x0008
0x0010
0x0020
No Metadata flags are specified and Meta Data will not be
returned. This is the Get Tag EPC syntax. The lower bits (X) are
specified as defined by
Tag Singulation/Select Functionality
Indicates that Metadata flags are to follow and the corresponding
Metadata shall be returned with the tag EPC. The lower bits (X)
are specified as defined by Tag Singulation/Select Functionality
.
When no flags are set no meta data will be returned, only the tag
EPC (including the tag CRC)
When bit 0 is set the Read Count will be returned
When bit 1 is set the LQI/RSSI will be returned
When bit 2 is set the Antenna ID will be returned
When bit 3 is set the Frequency will be returned
When bit 4 is set the Timestamp will be returned
When bit 5 is set the RFU (T
hingMagic Only
) will be returned
0x0040 When bit 6 is set the Protocol ID will be returned.
0x0080 When bit 7 is set Tag Data information will be returned. (0x0000 is always returned for Read Tag Single)
These fields are followed by the
Tag Singulation/Select Functionality
Get Tag EPC syntax, if necessary.
A response can contain the following information:
Command Set
85
86
Application Tag Commands
Read Tag Single Get EPC and Metadata Response Fields
Field Length Value
SOH
Length
OpCode
Status
Options
1 byte
1 byte
1 byte
2 bytes
1 byte
0xFF
Based on data returned
0x21
Status of command
As sent in request
Metadata Flags
Read Count
1
RSSI
1
Antenna ID
1
2 bytes
1 byte
1 byte
Metadata contained in response
Tag EPC/Antenna Read Count
Return Signal Strength Indicator
1 byte Antenna ID, 4 MSBs for TX and 4
LSBs for RX
Frequency in kHz Frequency
1
Timestamp
1
RFU
1
3 bytes
4 bytes RTC Timestamp
Protocol ID
2 bytes
1 byte
Reserved for Future Use - ThingMagic
Only
Protocol ID of tag (always 0x05 for
M5e/M5e-C)
Tag Data Length
EPC ID
Tag CRC
2 bytes
N bytes
2 bytes
Size of tag data to follow. Always
0x0000 for Read Tag Single
Tag EPC.
Tag EPC CRC
CRC 2 bytes Message CRC
1 - Conditionally returned depending on the Metadata Fields specified in the request.
Examples
An example command requesting AntennaID and Timestamp
Command Set
Application Tag Commands
Metadata Flags = 0x0004 OR 0x0010 = 0x0014 with no tag singulation criteria, just return the first tag found, is as follows:
FF
SOH
05
Length
21
OpCode
01
Timeout
E8 10
Options
00 14
Metadata Flags
2F 6D
CRC
Here is an example response to the example request specified above. The response contains the tag EPC info of the found tag and the requested tag read metadata:
AntennaID and Timestamp:
FF
SO
H
16
Length
21
OpCod e
00 00
Status Options Metadata
Flags
11
Ant
ID
00
B
B
5F
Timestamp
04 01 23 45 67 89
A
B
Tag EPC
C
D
EF 01 23 45 67 E6 C8
Tag CRC
37
CRC
C4
Here is another example request and response showing the use of
and getting the tag metadata for the specified tag. Note the Options Field includes the Select Options and bit 4 is set indicating the Meta Data flags follow.
This command requests the same tag read metadata as the previous example
(AntennaID and Timestamp) except now it is selecting a tag with a specific EPC value
(EPC=0x111122223333444455556666), which requires adding the appropriate
after the
Read Tag Single Get EPC and Metadata Request Fields
along with
Command Set
87
88
Application Tag Commands updating the Option field to set the appropriate flag for the tag singulation based on EPC value
FF
SOH
12
Length
21
OpCode
01
Timeout
E8 11
Options
00 14
Metadata Flags
60
Select
Data
Length
11 11 22 22 33 33 44 44 55 55 66
Select Data (EPC)
66
9F
CRC
C
E
The response contains the requested metadata and the tag EPC matching the requested tag EPC:
FF
SO
H
16
Length
21
OpCod e
00 00
Status Options Metadata
Flags
22
Ant
ID
0F C8 CD
Timestamp
B7 11 11 22 22 33 33 44
Tag EPC
44 55 55 66 66 18 35
Tag CRC
FE 7D
CRC
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_ANTENNA_NOT_CONNECTED – 503h
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
Command Set
Application Tag Commands
Read Tag Multiple (22h)
For deprecated version of this command see Appendix D:
The Read Tag Multiple command supports several different levels of functionality. In addition to performing a Basic Search Operation for all tags in the field it can also perform advanced searching and perform operations on the tags found. The different syntax for
Read Tag Multiple are defined as follows:
- Searches for and returns all tags in the field.
- Searches for and returns all tags in the field meeting Select
criteria as defined by
Tag Inventory With Embedded Operations
- Allows for operations (Write Tag Data, Lock
Tag, Kill Tag, Read Tag Data) to be performed on each tag inventoried.
Note
A Read Tag Multiple command will return early if it fills up the Tag Buffer before the timeout has expired. This will not result in an error. If a Read Tag
Buffer command is issued with an already full Tag Buffer an error will be returned.
Basic Tag Inventory
The Read Tag Multiple command performs a search for the specified period of time then returns the number of tags that have been found. Afterwards, multiple Get Tag Buffer commands can be sent to receive the found tag EPCs along with tag read metadata, including the antenna the tag was read on. The command allows the user to specify the method to use when multiple antennas are configured and connected along with indicating the command contains embedded commands:
Command Set
89
90
Application Tag Commands
Read Tag Multiple Search Flags
2
Flag Value
Description
Antenna Usage
(bits 0, 1, 2)
0x0000
1
0x0001
1
0x0002
1
0x0003
Use single antenna as configured by the most recent Set
Antenna command.
Automatically search on both monostatic antennas, starting with Antenna 1
. The search cycles through antennas moving to the next antenna when no more tags are found on the current antenna. It stops when the search timeout expires.
Automatically search on both monostatic antennas, starting with Antenna 2
. The search cycles through antennas moving to the next antenna when no more tags are found on the current antenna. It stops when the search timeout expires.
Automatically searches on all configured logical antennas,
using the Search Order defined using Set Multi-Antenna
Search Configuration . The search cycles through anten-
nas, in the order specified, moving to the next antenna when no more tags are found on the current antenna. It stops when the search timeout expires.
Embedded Command
(bit 3) will be executed on each inventoried tag.
Note:
This bit should only be set when using the Tag
Inventory With Embedded Operations
syntax.
Note:
1- Only one of these flags should be set since both Antenna 1 and 2 cannot be the starting antenna.
2 -Multiple Flags can be set (perform a binary OR) to specify different behaviors. ex: Search Flags = 0x0006 indicates a multiple antenna search starting on antenna2 is to be performed and the embedded command specified is to be executed on each tag.
Note:
When performing multi-antenna searches and
Tag Singulation/Select Functionality is used, the
Select operation will be performed once per antenna. More specifically, during a single
search comes back around to an antenna during the same command the Select is not issued again.
Command Set
Application Tag Commands
Examples
For example, the syntax for a Read Tag Multiple with automatic multi-antenna search starting with antenna1 is:
03 E8
Timeout (ms)
3F
CRC
8E FF
SOH
04
Length
22
OpCode
00 01
Antennas Flag
The response format for both is the following:
FF
SOH
01
Length
22
OpCode
00
Status
00 02
# Tag IDs Found
46
CRC
BA
Tag Inventory with Select
If you want to inventory only tags meeting a specific criteria this syntax should be used.
The search criteria is specified using the
it will perform the same search as the
syntax. Otherwise, it will return
the number of tags found matching the specified criteria. The tag EPCs and Meta Data will be available in the Tag Buffer. If no tags are found, a fault code is returned. The required fields are as follows:
Read Tag Multiple with Select Fields
Field
Select Options
Search Flags
Value
[1 byte]
[2 bytes]
Timeout
Access Password
[2 bytes]
[4 bytes]
Description
Read Tag Multiple Search Flags indicating antenna
usage. Bit 3 must be 0, no embedded commands.
Indicates how long the command should spend searching.
The Access Password is only used with Tag Inventory With Embedded Operations
for the embedded command. With this syntax it should be specified as
0x00000000.
Note:
If Select Options=0x00 this field should be omitted.
The remaining, appropriate fields depending on the value of Select Options.
Command Set
91
92
Application Tag Commands
Examples
Here is an example request and response showing the use of
to inventory tags which meet a specific criteria:
This command will inventory all tags with an EPC value ending in 0x66, which requires
syntax
FF
SOH
0F
Length
22
OpCode
04
Options
(EPC Mem)
00 00
Search Flags
03
Timeout
E8
00 00 00 00 00
Access Password
00 00 78
Select Address (bits)
08 66
Select
Data
Length
(bits)
Select
Data
D
E
CRC
C0
Note
The Select Options field of the
in the request is specified at the beginning of the command followed by the Search Flags, Timeout,
Access Password then the rest of the Tag Singulation Fields. This is different than the typical format for Select fields. Also, this syntax always requires an
Access Password be specified. Since only Reserved Memory can be read locked and Reserved Memory cannot be used for singulation the Access
Password must be 0x00000000
The response contains the number of tags found matching the Select criteria specified.
Use
to access the tag EPCs and Tag Read Meta Data:
FF
SOH
04
Length
22
OpCode
00
Status
00 04
Options
(EPC Mem)
00 00
Search Flags
02
Tag Found
B7
CRC
6E
Tag Inventory With Embedded Operations
In addition to inventorying tags, Read Tag Multiple can be used to perform an operation
on each tag in a population of tags. Starting with the
define the population of tags the operation is to be performed on, the Search Flag bit 3
(0x0004) can be set to indicate embedded commands are to be performed on the inventoried commands. The required fields are as follows:
Command Set
Application Tag Commands
Field
Select Options
Search Flags
Timeout
Access Password
Value
[1 byte]
[2 bytes]
[2 bytes]
[4 bytes]
Read Tag Multiple Embedded Command Fields
Description
The Options value of the Tag Singulation Fields
Bit 3 of the Read Tag Multiple Search Flags must be set indicating this request contains
embedded command(s).
Indicates how long the command should spend searching AND performing the embedded command. It may be desirable to specify a longer timeout if a large number of tags are likely to get the embedded command executed on them.
The Access Password of the tags expected to be inventoried for the embedded command, if they are locked. If the tags are not locked specify 0x00000000.
Note:
If operating on locked tags, only tags which meet the Select criteria and matching passwords will get a successful execution of the embedded command.
Note:
If Select Options=0x00 this field should be omitted.
The remaining, fields depending on the value of Select Options.
The number of embedded commands to follow. [Only one allowed]
Embedded
Command Count
Embedded
Command Length
Embedded
Command OpCode
[1 byte]
[1 byte]
[1 byte]
The fields and values required by the embedded command.
Length of embedded commands. Follows standard Length value calculation: number of bytes after OpCode.
The OpCode of the embedded command. Currently supports:
When embedding Read Tag Data the complete set of data requested is returned for the first tag that responds with the command response, but up to the first 32 bytes of data requested is returned for every tag that responds and is stored in the tag buffer with the
Example with Embedded Read Tag Data
below for details.
The embedded commands do not support Tag Singulation as it is already performed during the inventory operation. The Options field for the embedded command must be
0x00
.
Note:
The Timeout field for embedded commands must be 0x0000.
Command Set
93
Application Tag Commands
Read Tag Multiple Embedded Response Fields
Field Value Description
Status
Select Options
[2 bytes]
[1 byte]
Error Code if command failed, otherwise 0x0000 for Success
Options set in the Request Command
Search Flags
Tags Found
Embedded Command Count
[2 bytes]
[1 byte]
Embedded Command OpCode [1 byte]
Operations Succeeded
[1 byte]
[2 bytes]
Search Flags set in the Request Command
Number of tags found and added to the Tag Buffer
matching Select criteria. Follows the standard criteria of adding tags the Tag Buffer. if the Tag Buffer already has tags in it they will not be counted towards
Tags Found. However, if they match the Select Criteria they will have the operation performed on them. For this reason it is important to always make sure the Tag Buffer is clear before any Read Tag Multiple execution to insure accurate response information.
The number of embedded commands to follow. [Currently only supports one]
The OpCode of the embedded command as specified in the request command.
Number of Embedded command operations which succeeded.
Note:
Depending on the Gen2 Session/User Mode used the
Operations Succeeded/Failed counts can be misleading since in Session 0, for example, the tag may respond many times during an inventory round and the command may be attempted many times. This would result in counts higher than the actual number of tags the operation succeeded or failed on.
Operations Failed [2 bytes] Number of Embedded command operations which failed.
Note:
As noted above this number can be indicating the command failed multiple times on the same tag. These values should be used in combination with Tag Found and checking the Tag
Buffer to insure the operation was completed on the desired tags.
The fields and values returned by the embedded command.
Example with Embedded Write Tag Data
Here is an example request and response showing the use of
to inventory tags which meet a specific criteria and then setting the Access
as an embedded command:
This command will inventory all tags with an EPC value ending in 0x34, which requires adding the appropriate
94
Command Set
Application Tag Commands
to write 0x12345678 into the Reserved Memory Bank starting at
Word address 0x00000002 (Access Password)
FF
SOH
1E
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
00 00 00
Access Password
00 00 00 00 78
Select Data Address
(bits)
08 34
Select
Data
Length
(bits)
Select
Data
01
Embd
Cmd
Count
0C
Embd
Cmd
Lengt h
24
Embd
Cmd
OpCod e
00 00
00
Embd Cmd
Timeout
(Not Used)
Embd
Cmd
Options
(Must be
0x00)
00 00 00 02
Write Address (Words)
00
Write
Mem-
Bank
12 34 56
Write Data
78
AF
CRC
29
The response contains the number of tags found matching the Select criteria specified
and the number of embedded command operations which succeeded and failed. Use
to access the tag EPCs and Tag Read Meta Data for the Tags Found.
Tags in the buffer may or may not have had successful execution of the embedded command on them:
FF
SOH
0A
Length
22
OpCod e
00
Status
00 04
Options
00 04
Search Flags
02
Tag
Found
01
Embd
Cmd
Count
24
Embd
Cmd
OpCode
00 02
Operations
Succeeded
00 00
Operations
Failed
FF
CRC
5E
Note
Depending on the Gen2 Session/User Mode used the Operations
Succeeded/Failed counts can be misleading since in Session 0, for example, the tag may respond many times during an inventory round and the command may be attempted many times. This would result in counts higher than the actual number of tags the operation succeeded or failed on.
The above commands were run in User Mode = Portal.
Note
When embedding write operations, including Lock and Kill, in Read Tag
Multiple the Read TX Power will be used for the entire operations: inventory and the write. The power will not switch to the Write TX Power for each Write operation.
Command Set
95
Application Tag Commands
Example with Embedded Read Tag Data
When using Read Tag Multiple with an embedded Read Tag Data command an extra field containing the requested Data from the first tag which responded matching the Select criteria is added to the response. Up to 4 bytes of tag data for the other tags responding, if any, is available as
. This command provides the added benefit over
simply using just a Read Tag Data with Select of being able to identify other tags matching the criteria which still may need to be written or which you didn’t expect to match. An example of sending an embedded Read Tag Data and its response is as follows:
This command will inventory all tags with an EPC value ending in 0x34, which requires adding the appropriate
to verify that 0x12345678 was written into the Reserved Memory
Bank starting at Word address 0x00000002 (Access Password):
FF
SOH
1B
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
00 00 00
Access Password
00 00 00 00 78
Select Data Address
(bits)
08 34
Select
Data
Length
(bits)
Select
Data
01 09
Embd
Cmd
Count
Embd
Cmd
Lengt h
28
Embd
Cmd
OpCod e
03 E8
00
Embd Cmd
Timeout
(Not Used)
Embd
Cmd
Options
(Must be
0x00)
00
Read
Mem-
Bank
00 00 00 02
Read Address (Words)
02
Read
Word
Count
71
CRC
FE
The response contains the number of tags found matching the Select criteria specified
and the number of embedded command operations which succeeded and failed. Use
to access the tag EPCs and Tag Read Meta Data for the Tags Found.
Tags in the buffer may or may not have had successful execution of the embedded command on them:
FF 0e
SOH Length
22
OpCod e
00
Status
00 04
Options
00 04
Search Flags
03
Tag
Found
01
Embd
Cmd
Count
28
Embd
Cmd
OpCode
00 01
Operations
Succeeded
00 00
Operations
Failed
11 22 33
Data Read
44 DE
CRC
02
96
Command Set
Command Set
Application Tag Commands
Example with Embedded Kill Tag
This command will inventory all tags with an EPC value with the first 88bits equal to
0x30940425C4C1967400004E, which requires adding the appropriate
to the
syntax then will use
assuming they have their Kill password set to 0x12345678:
FF
SOH
20
Length
22
OpCode
01
Options
(EPC Mem)
00 04
Search
Flags
00 FA
Timeout
87 65 43
Access Password
21 58
Select
Data
Length
(bits)
30 94 04 25 C4 C1 96 74 00 00 4E
Select Data
01
Embd
Cmd
Count
08
Embd
Cmd
Lengt h
26
Embd
Cmd
OpCod e
00 00
00
Embd Cmd
Timeout
(Not Used)
Embd
Cmd
Options
(Must be
0x00)
12 34 56
Kill Password
78 00
RFU
5F
CRC
C4
Note
If the tags being inventoried and operated on with the embedded command have their Access Password set then the Access Password field must be set accordingly, otherwise it can be left as zero.
The response contains the number of tags found matching the Select criteria specified and the number of embedded command operations which succeeded and failed. Use
to access the tag EPCs for the Tags Found. Tags in the buffer may or may not
have had successful execution of the embedded command on them:
FF
SOH
0a
Length
22
OpCod e
00
Status
00 01
Options
00 04
Search Flags
01
Tag
Found
01
Embd
Cmd
Count
26
Embd
Cmd
OpCode
00 02
Operations
Succeeded
00 00
Operations
Failed
D9
CRC
80
Note
In this example it shows the number of Tags Found lower than the
Operations Succeeded. This is because, as with any Read Tag Multiple execution, if the Tag Buffer already has a specific tag in it, it will not be counted towards Tags Found. However, because it matches the Select
Criteria it will have the operation performed on it. For this reason it is important to always make sure the Tag Buffer is clear before any Read Tag
Multiple execution.
97
98
Application Tag Commands
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_TAG_ID_BUFFER_FULL – 601h
FAULT_ANTENNA_NOT_CONNECTED – 503h
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
Write Tag EPC (23h)
The Write Tag EPC command should be used when updating the EPC value of a tag. It is preferred over using
because Write Tag EPC will automatically lengthen or shorten the EPC ID, by modifying the PC bits, according to the Tag EPC specified. If Write Tag Data is used, the specified data will be modified but the EPC ID length will not be modified.
Note
Write Tag EPC will always use Gen2 Q=0 when
set to Dynamic Q. For use with large tag populations a Static Q
appropriate for the population should be used to avoid collisions.
The Write Tag EPC command takes the following fields:
Command Set
Application Tag Commands
Write Tag EPC Command Fields
Field Value Description
Length
OpCode
[1 byte]
0x23
Number of bytes in the command following the OpCode.
Write Tag EPC
Time Out
Select Options
[2 bytes]
[1 byte]
Command timeout in milliseconds.
The Options value of the
Access Password [4 bytes] The Access Password of the tags expected to be inventoried for the embedded command, if they are locked. If the tags are not locked specify 0x00000000.
Note:
If operating on locked tags, only tags which meet the Select criteria and matching passwords will get a successful execution of the embedded command.
Note:
If Select Options=0x00 this field should be omitted.
Tag EPC ID
The remaining, fields depending on the value of Select Options.
[M bytes]
Up to 496-bit ( depending on EPC Length parameter setting in
) tag ID to write to the Tag
The reader sends a Fault Code / ACK response back to the host.
An example of Write Tag EPC command sequence of events and format is shown next:
1.
Starts a timer on the reader.
2.
Wakes the tag.
3.
Programs the tag with the EPC ID
4.
Reads the tag and verifies if the write succeeded.
Note
The verify operation uses the same power level as the write operation. It does not change to the Read power level.
5.
Sends back an ACK if OK or a fault code for timeout or other faults.
FF
SOH
00
Length
23
OpCod e
00 00
Status
??
CRC
??
Command Set
99
100
Application Tag Commands
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_ANTENNA_NOT_CONNECTED – 503h
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
Write Tag Data (24h)
For the deprecated version of this command see Appendix D:
The Write Tag Data command writes to the specified memory bank and data address location within that memory bank of a tag. The tag which will be written to can be specified using the
or, if Option=0x00 of the Tag Singulation Fields is specified, it will attempt to write to the first tag it finds. If no tag is in the field, the memory location doesn’t exist or is unwriteable, or the Select criteria cannot be satisfied a fault code is returned.
In addition to the Tag Singulation Fields the Write Tag Data command takes several fields which specify the data which will be written to the tag. These fields are:
Command Set
Application Tag Commands
Field
Write Address
Access Password
Value
4 bytes
Write MemBank 1 byte
Write Data N bytes
4 byes
Write Tag Data Fields
Description
The Address field is the offset in the specified Memory Bank, in 16-bit words, where the contents of the Data field is written.
It corresponds to the
WordPtr
argument in the Gen2 specification.
Note:
Addresses are always zero-based. Specifying 0x00 indicates starting at the first address location.
The MemBank field specifies which of the tag’s memory banks the data is to be written to. The values correspond to the
Memory Bank values as specified in the
Gen2
specification.
They are:
0x00 = Reserved
0x01 = EPC
0x02= TID
0x03 = User Memory
The data to be written to the tag in Memory bank [MemBank] starting at address [Address].
The Access Password for the tag, if the tag is locked. For an unlocked tag AccessPwd=0x00000000.
Note:
When Option=0x00 is specified the Access Password is not used.
Command Set
101
Application Tag Commands
Examples
The following example will attempt to write to Reserved Memory to set the Kill password=0x11112222. It will write this data to a tag matching the following criteria for a max timeout of 1000 ms.
Memory Bank = User Memory.
Starting Address = bit 32
Select Data = 0x1234
The Reserved Memory bank is not locked so the Access Password is zero
FF
SOH
17
Lengt h
24
OpCode
03 E8
Timeout (ms)
03
Option
00 00 00 00
Write Address
00
Write
MemBank
00 00 00 00 00 00 00 20
Access Password Select Address
10
Select
Data
Length
12 34
Select
Data
11 11 22 22
Write Data
3E
CRC
71
If Option=0x00 or 0x01 is used then the unused
must be removed from the request.
Note
If Option=00, the write tag data is performed without any select criteria resulting the first tag found being written. In that case there is no way to determine what tag gets written to unless there is only one tag in the RF field.
The next example will attempt to write 4 words to User Memory starting at the second word. It will write this data to a tag matching the following criteria for a max timeout of
1000 ms.
EPC ID= 0x0123456789ABCDEF01234567
The User Memory bank is not locked so the Access Password is zero
FF
SOH
21
Lengt h
24
OpCode
03 E8
Timeout (ms)
01
Option
00 00 00 02
Write Address
03
Write
MemBank
00 00 00 00
Access Password
60
Select
Data
Length
102
Command Set
Application Tag Commands
01 23 45 67 89 AB DC EF
Select Data
01 23 45 67 11 11 22 22 00 00 00 00
Write Data
81
CRC
E7
Note:
Try reading back the value written in this example with the Read Tag Data
showing reading from the same tag.
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_PROTOCOL_WRITE_FAILED – 406h
FAULT_PROTOCOL_INVALID_ADDRESS – 409h
FAULT_GENERAL_TAG_ERROR – 40Ah
FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
FAULT_ANTENNA_NOT_CONNECTED – 503h
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
Lock Tag (25h)
For the deprecated version of this command see Appendix D:
The Lock Tag command locks the specified memory bank of a tag. The tag which will be
locked can be specified using the
Singulation Fields is specified, it will attempt to lock the first tag it finds. If no tag is in the field, the memory location doesn’t exist or is unlockable, or the Select criteria cannot be satisfied a fault code is returned.
Note
Using Option=0x05 for the
is not allowed for Lock Tag.
In addition to the Tag Singulation Fields the Lock Tag command takes several fields which specify how the tag is to be locked. These fields are:
Command Set
103
Application Tag Commands
Lock Tag Fields
Field Value Description
AccessPwd
Mask Bits
1
Action Bits
1
4 byes
2 bytes
2 bytes
The Access Password for the tag.
The Mask bits specify which fields should be modified according to the Actions bits. When a Mask Bit =0 the corresponding Action bit is not applied and the current lock setting is retained. When a Mask Bit =1 the corresponding Action bit is applied and the new lock setting is implemented.
The Action bits specify whether to assert or deassert a lock behavior for the associated memory location. Action
Bits are only applied if the corresponding Mask Bits =1.
1-The Mask and Action bits correspond to the identically named fields described in Section 6.3.2.10.3.5 of the Gen2 specification.
The values of the Mask and Action bits indicate how a tag is to be locked. The 10 Least
Significant Bits of each 16-bit argument are used to indicate the lock behavior for each memory bank (Action Bits) and which of those behaviors to apply (Mask Bits). These bits and their corresponding behaviors are:
Bit
15 14 13
Mask
X
Action
X
Unused
X
X
X
X
X
X
First Byte
12 11 10 9
X
X
X
X
8
Kill Pwd
Set?
Set?
R/W
7
Access Pwd
Set?
Set?
Perm R/W
6 5
Perm W
Second Byte
4
EPC Mem
Set?
Set?
Perm
3
TID Mem
Set?
Set?
W
2 1
Perm W
0
User Mem
Set?
Set?
Perm
For each bit in the Mask field where Set?=1 the corresponding Action bit will be applied and the specified lock setting (R/W, W. Permanent) will be asserted (1) or de-asserted
(0). Please see the Gen2 specification for more information on Lock Action functionality.
Note
Operations to lock/unlock memory banks can be combined by passing Mask and Action fields with multiple changes, but each bank must exist and be lockable independently. For example, passing 0xFFFF in the Mask field and
104
Command Set
Application Tag Commands
0x0000 in the
Action
field unlocks all the memory banks as long as all memory banks exist and are lockable.
Examples
The following example shows an attempt to apply a temporary (not permanent) Write lock on the EPC memory (Option=0x01) of a tag whose EPC
ID=0x111122223333444455556666 and whose access password=0x11223344:
FF 18
SOH Length
25
OpCode
03 E8
Timeout (ms)
01
Option
11 22 33 44 00
Access Password
20
Mask Bits
00 20
Action Bits
60h
Select
Data
Length
11 11 22 22 33 33 44
44 55 55 66 66
Select EPC ID
9E
CRC
7A
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_PROTOCOL_INVALID_ADDRESS – 409h
FAULT_ANTENNA_NOT_CONNECTED – 503h
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
Kill Tag (26h)
For the deprecated version of this command see Appendix D:
.
The Kill Tag command kills the specified tag. The tag which will be killed can be specified
or, if Option=0x00 of the Tag Singulation Fields is specified, it will attempt to kill the first tag it finds. If no tag is in the field, the kill password is zero, or the Select criteria cannot be satisfied a fault code is returned.
In addition to the Tag Singulation Fields the Kill command takes the tag’s Kill Password and an extra 1 byte field for future use (RFU).
Command Set
105
Application Tag Commands
Examples
The following example shows an attempt to kill a tag whose EPC
ID=0x112233445566778899AA and whose Kill password=0x11112222:
FF
SOH
13
Length
26
OpCode
03 E8
Timeout (ms)
01
Option
11 11 22 22
Kill Password
00
RFU
50
Select
Data
Length
11 22 33 44 55 66 77
88 99 AA
Select EPC ID
DD DB
CRC
Note
If the tag’s kill password is set to 0, the protocol does not allow the tag to be killed. A non-zero kill password must be set (using the
Write Tag Data
command) before the kill command succeeds. The RFU field should be set to 0.
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_PROTOCOL_INVALID_ADDRESS – 409h
FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch
FAULT_PROTOCOL_KILL_FAILED - 40Eh
FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
FAULT_ANTENNA_NOT_CONNECTED – 503h
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
106
Command Set
Application Tag Commands
Read Tag Data (28h)
For the deprecated version of this command see Appendix D:
The Read Tag Data command reads the specified memory bank at data address location within that memory bank of a tag. The tag which will be read can be specified using the
or, if Option=0x00 of the Tag Singulation Fields is specified, it will
attempt to read from the first tag it finds. If no tag is in the field, the memory location doesn’t exist or is read locked, or the Select criteria cannot be satisfied a fault code is returned.
In addition to the Tag Singulation Fields the Read Tag Data command takes several fields which specify the data which will be read from the tag. These fields are:
Read Tag Data Fields
Field Value
Read MemBank 1 byte
Read Address
WordCount
4 bytes
1 byte
Description
The MemBank field specifies which of the tag’s memory banks the data is to be read from. The values correspond to the
Memory Bank values as specified in the
Gen2
specification.
They are:
0x00 = Reserved
0x01 = EPC
0x02= TID
0x03 = User Memory
The Address field is the offset in the specified Memory Bank, in 16-bit words, to start reading from. It corresponds to the
WordPtr
argument in the Gen2 specification.
Note:
Addresses are always zero-based. Specifying 0x00 indicates starting at the first address location.
The number of words (16 bit chunks) of data to read from memory bank [MemBank] starting at offset [ReadAddress].
The Access Password for the tag, if the tag is read locked. For an unlocked tag AccessPwd=0x00000000.
Access Password
4 byes
The Basic syntax which returns only the requested Tag Data is defined in
.
With additional Option bits set, Read Tag Data can also return
the syntax in
.
Command Set
107
108
Application Tag Commands
Get Tag Data
Examples
The following example will attempt to read the Kill Password (the first 2 words) from
Reserved Memory. It will read this data from a tag matching the following criteria for a max timeout of 1000 ms.
Memory Bank = User Memory.
Starting Address = bit 32
Select Data = 0x1234
The Reserved Memory bank is not locked so the Access Password is zero
FF
SOH
14
Lengt h
28
OpCode
03 E8
Timeout (ms)
03
Option
00
Read
MemBank
00 00 00 00
Read Address
02
Word-
Count
00 00 00 00
Access Password
00 00 00 20
Select Address
10
Select
Data
Length
12 34
Select
Data
D1
CRC
E7
If Option=0x00 or 0x01 is used then the unused
and the Access
Password (for Option=0x00 only) must be removed from the request.
The response to this Read Data command example is:
FF
SOH
05
Length
28
OpCode
00
Status
00 03
Option
11 11
Data
22 22 10
CRC
BF
The next example will attempt to read four words from User Memory starting at the third word (0x0002). It will read this data from a tag matching the following criteria for a max
Command Set
Application Tag Commands timeout of 1000 ms. Note the Options field, no metadata is requested unlike the previous example.
EPC ID = 0x0123456789ABCDEF01234567.
The User Memory bank is not locked so the Access Password is zero
FF
SOH
1A
Lengt h
28
OpCode
03 E8
Timeout (ms)
01
Option
03
Read
MemBank
00 00 00 02
Read Address
04
Word-
Count
00 00 00 00
Access Password
60
Select
Data
Length
01 23 45 67 89 AB CD
Select Data
EF 01 23 45 67 7A
CRC
C1
The response to this Read Data command example is:
FF
SOH
09
Length
28
OpCod e
00
Status
00 01
Option
AA BB CC DD
Data Read
00 00 00 00 E7
CRC
54
Note: Try changing the value at this memory location with the Write Tag Data
writing to the same tag.
Get Tag Data and Meta Data
In addition to getting the tag data returned you can also get
found tag. This version of Read Tag Data requires bit 4 of the Option flag to be set and takes an additional Metadata Flags field which defines what metadata will be returned.
The following table lists the supported values for these fields.
Command Set
109
Application Tag Commands
110
Read Tag Data Get Data and Metadata Request Fields
Field Value Description
Option
Metadata Flags
(to specify more than one OR the values together)
Bit 4=0
(0x0X)
Bit 4=1
(0x1X)
0x0000
0x0001
0x0002
0x0004
0x0008
0x0010
0x0020
No Metadata flags are specified and Meta Data will not be returned. This is the
Get Tag Data syntax. The lower bits (X) are
specified as defined by
Tag Singulation/Select Functionality
Indicates that Metadata flags are to follow and the corresponding
Metadata shall be returned with the tag data. The lower bits (X)
are specified as defined by Tag Singulation/Select Functionality
.
When no flags are set no meta data will be returned, only the tag data.
When bit 0 is set the Read Count will be returned
When bit 1 is set the LQI/RSSI will be returned
When bit 2 is set the Antenna ID will be returned
When bit 3 is set the Frequency will be returned
When bit 4 is set the Timestamp will be returned
When bit 5 is set the RFU (T
hingMagic Only
) will be returned
0x0040 When bit 6 is set the Protocol ID will be returned.
0x0080 When bit 7 is set Tag Data information will be returned.
Tag Data is always returned for Read Tag Data, this field cause an extra 2 bytes, always 0x0000, to be returned for Tag Data
Length
These fields are followed by the
Tag Singulation/Select Functionality
(set appropriate bits in the Option field defined above, do not specified an additional Option field), used the same as defined in the
Get Tag Data syntax, as necessary.
A response can contain the following information:
Read Tag Data Get Data and Metadata Response Fields
Field
SOH
Length
OpCode
Length
1 byte
1 byte
1 byte
Value
0xFF
Based on data returned
0x28
Command Set
Command Set
Application Tag Commands
Field Length Value
Status 2 bytes 0x0000 for success. Otherwise see
Options
Metadata Flags
Read Count
1
RSSI
1
Antenna ID
1
1 byte
2 bytes
1 byte
1 byte
As sent in request
Metadata contained in response
Tag EPC/Antenna Read Count
Return Signal Strength Indicator
1 byte Antenna ID, 4 MSBs for TX and 4
LSBs for RX
Frequency in kHz Frequency
1
Timestamp
1
RFU
1
3 bytes
4 bytes RTC Timestamp
Protocol ID
1
2 bytes
1 byte
Reserved for Future Use - ThingMagic
Only
Protocol ID of tag (always 0x05 for
M5e/M5e-C)
N/A - always zero for Read Tag Data. Tag Data Length
1
Tag Data
2 bytes
N bytes Number of bytes of Tag Data requested.
CRC 2 bytes Message CRC
1 - Conditionally returned depending on the Metadata Fields specified in the request.
111
Application Tag Commands
Examples
The following example will attempt to read the Access Password (the first 2 words) from
Reserved Memory. It will read this data from a tag matching the following criteria for a max timeout of 1000 ms.
Memory Bank = EPC.
Starting Address = bit 120 (beginning of the last byte of the EPC value: 16 PC bits + 16
CRC bits + 88 EPC bits)
Select Data = 0x34
The Reserved Memory bank is not locked so the Access Password is zero
FF
SOH
15
Lengt h
28
OpCode
03 E8
Timeout (ms)
14
Option
00 14
Meta
Data
Flags
00
Read
MemBank
00 00 00 02
Read Address
02
Word-
Count
00 00 00 00
Access Password
00 00 00 78
Select Address
08 34
Select
Data
Length
Select
Data
9C
CRC
0E
The response to this Read Data command example is:
FF
SOH
0C
Length
28
OpCod e
00
Status
00 14
Option
00 14
Meta Data
Flags
22
Antenn a ID
00 00 00 15
Timestamp
12 34 56 78 B2
Tag Read Data CRC
B4
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_PROTOCOL_INVALID_ADDRESS – 409h
FAULT_GENERAL_TAG_ERROR – 40Ah
FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
112
Command Set
Application Tag Commands
FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
FAULT_ANTENNA_NOT_CONNECTED – 503h
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
Get Tag Buffer (29h)
After a Read Tag Multiple command is executed, the found tags are stored in an internal
. The Get Tag Buffer command can perform several different operations
depending on the syntax used. These operations are:
Get tags remaining in the tag buffer
Get tag EPCs
.
Get Tags Remaining
To determine the number of tags remaining in the buffer, send the Get Tag Buffer command with a data length of zero:
FF
SOH
00
Length
29
OpCode
1D 26
CRC
This command returns the current read index, the location of the next tag to be read, and the current write index, the location where the next tag will be written. These two numbers can be used to get the number of tags left in the tag buffer:
Tags Left = WriteIndex - ReadIndex
The following response shows there are three tags left in the buffer, and the first one has already been read (the read index parameter starts counting from 0.):
FF
SOH
04
Length
29
OpCode
00
Status
00 00 01
ReadIndex
00 04
WriteIndex
87
CRC
72
Command Set
113
Application Tag Commands
Get Tag EPCs
When you want to get the tag EPCs out of the buffer and don’t care about the tag read metadata, the options available with this syntax maybe useful. This syntax reads out the requested number of tags from the buffer. A maximum of 13 tags are read at a time, less if Max EPC Length is set to 496 bits. Multiple Get Tag Buffer commands may be required to obtain the complete results from a single Read Tag Multiple command. If more tags are requested than remain in the buffer an error will be returned.
All tag buffer indexes are encoded as 16-bit unsigned integers. The indexes start counting from 0. Thus, a start index of 0 indicates tag #1, and a start index of 10 would indicate tag #11.
There are two ways to read tag EPCs out of the buffer when you only want EPC values.
The first way is to send a Get Tag Buffer command with the desired number of tags,
n.
This retrieves the next
n
tags, starting from the current read index. In the previous example, the read index was 1, indicating that one tag was already read. To read the next two tags, set the number of tags parameters to 2. This returns tags number 2 and 3 in the tag buffer:
FF
SOH
02
Length
29
OpCode
00 02
# Tag IDs to Return
57
CRC
EB
When using the Get Tag Buffer command in this way, the read index is automatically incremented internally. Thus, if the read index was ‘1’ before getting two tags, then it is incremented to ‘3’ at the end of this command.
Another way to get the second and third tags is to explicitly send the start and end indexes of the tags to read. This is used to retrieve any contiguous block of tag buffer entries at any time.
114
FF
SOH
04
Length
29
OpCode
00 01
Start Idx
00 03
End Idx
CC
CRC
94
Using the start and end index method does not affect the read index that is internally stored in the module. The above request returns a message with two tags. The length of each tag EPC record returned is defined based on the max EPC length configured with
, regardless of the size of a specific tag’s EPC. The sizes
and fields of the EPC portion of a tag buffer entry is defined in the
For example:
Command Set
Application Tag Commands
A 64-bit tag has the length set to 0x60 (16-bit PC + 64-bit tag EPC + 16-bit tag CRC), but only the first 12 bytes of the tag record is filled in, the trailing bytes, after the CRC are padded with zeros.
An 96-bit GEN2 tag, the length is 0x80 (16-bit PC (Protocol Control) word + 96-bit tag
EPC + 16-bit tag EPC CRC).
In the response below, two tag EPCs are returned. Tag #1 is a 96-bit EPC tag and tag #2 is a 64-bit EPC tag.
FF
SO
H
24
Length
29
OpCod e
00 00
Status
00
EPC
Length
80 30 00
PC Word
11 11 22 22 33 33 44
Tag EPC
44 55 55 66 66 18 35
Tag CRC
00
EPC
Length
60 20 00
PC Word
11 11 22 22 33
Tag EPC
33 44 44 C2 41
Tag CRC
00
Padding
00 00 00
D3
CRC
32
Note
Using this syntax the number of tags in the response is not specified. It must be determined by the message length.
Get Tag EPCs and Metadata
Using this syntax for getting information from the tag buffer provides several benefits:
When at tag EPC is returned there is no padding if the actual tag EPC is shorter than the configured max EPC length. This helps minimize the amount of data returned.
can be returned.
Command Set
115
116
Application Tag Commands
In the event of a communication error the last Get EPC and Metadata request can be repeated.
When data is requested using this syntax the response will contain as many tags as can be fit in the response packet. The response will indicate how many tags were returned and should be processed accordingly.
This version of Get Tag Buffer takes two additional fields: the Metadata Flags which defines what metadata will be returned and the Read Options which specifies special read functionality. The following table lists the supported values for these fields.
Get EPC and Metadata Request Fields
Field Value
Metadata Flags
(to specify more than one OR the values together)
0x0000
0x0001
0x0002
0x0004
0x0008
0x0010
0x0020
0x0080
Read Option 0x00
0x01
Description
When no flags are set no meta data will be returned, only the tag
EPC (including PC bits and tag CRC)
When bit 0 is set the Read Count will be returned
When bit 1 is set the LQI/RSSI will be returned
When bit 2 is set the Antenna ID will be returned
When bit 3 is set the Frequency will be returned
When bit 4 is set the Timestamp will be returned
When bit 5 is set the RFU (T
hingMagic Only
) will be returned
When bit 7 is set up to 4 bytes of tag data will be returned.
Note:
This data is only available if the tag buffer entries are
from a Read Tag Multiple (22h) with embedded
.
Read the next set of tags from the Tag Buffer
Re-send the last set of tags.
Note:
When setting this option the tags will be resent starting at the same ReadIndex as the last command. If the metadata requested is different than the last request the number of tags returned might be different. To get those
‘missing’ tags, additional Get Tag Buffer commands should be sent without the re-send option, otherwise it will reset the ReadIndex again.
Examples
An example command requesting Read Count, AntennaID and Timestamp
Command Set
Application Tag Commands
Metadata Flags = 0x0001 OR 0x0004 OR 0x0010 = 0x0015 is as follows:
FF
SOH
03
Length
29
OpCode
00 15
Metadata Flags
00
Read Options
97
CRC
55
A response contains the following information:
Get EPC and Metadata Response Fields
Field
SOH
Length
OpCode
Status
Metadata Flags
Read Options
Tag Count
Read Count
1
RSSI
1
Antenna ID
1
Frequency
1
Timestamp
1
RFU
1
Protocol ID
1
Length
1 byte
1 byte
1 byte
2 bytes
2 bytes
1 byte
1 byte
1 byte
1 byte
1 byte
3 bytes
4 bytes
2 bytes
1 byte
Value
0xFF
Based on data returned
0x29
0x0000 for success. Otherwise see
Metadata contained in response
As sent in request
Number of tags in response
Tag EPC/Antenna Read Count
Return Signal Strength Indicator
Antenna ID, 4 MSBs for TX and 4 LSBs for RX
Frequency in kHz
RTC Timestamp
Reserved for Future Use - ThingMagic
Only
Protocol ID of tag read (always 0x05 for
M5e/M5e-C)
Command Set
117
Application Tag Commands
Field Length Value
Tag Data Length
Tag Data
1
EPC Length
1
2 byte
N bytes
2 bytes
Length, in bits, of the tag data read for this tag. This value indicates how many bytes (ceiling[bits/8]), up to 32, will follow.
Example:
if the value is 0x1D (29) then 4 bytes will follow:
29/4 = 3.625 -- ceiling(3.625) = 4.
Number of bytes of tag data as specified in
Tag Data Length
Number of bits in EPC including PC and
CRC bits
Tag EPC Protocol Control bits
Tag EPC.
PC Word
EPC ID
2 bytes
N bytes
Tag CRC 2 bytes Tag EPC CRC
Repeat fields starting at
Read Count
for remaining tags in message as defined by
Tag Count
CRC 2 bytes Message CRC
1 - Conditionally returned depending on the Metadata Fields specified in the request.
Here is an example response to the example request specified above. The response contains two tags as specified in the Tag Count field each with its EPC info and requested tag read metadata: Read Count, AntennaID and Timestamp:
FF
SO
H
34
Length
29
OpCod e
00 00
Status
00 15
00 02
Metadata
Flags
Read
Options
Tag
Count
22
Read
Count
11
Ant
ID
02 50 CE
Timestamp
F6 00
EPC
Length
80 31 C1
PC Word
11 11 22 22 33 33 44
Tag EPC
44 55 55 66 66 FB 15
Tag CRC
OE
Read
Count
11
Ant
ID
04 1D 3D
Timestamp
3C 00
EPC
Length
80 30 00
PC Word
05 00 00 00 00 00 00
Tag EPC
00 00 00 23 54 4A C8
Tag CRC
118
Command Set
Application Tag Commands
1A
CRC
B8
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_TAG_ID_BUFFER_NOT_ENOUGH_TAGS_AVAILABLE – 600h
FAULT_TAG_ID_BUFFER_NUM_TAG_TOO_LARGE – 603h
Clear Tag Buffer (2Ah)
The Clear Tag Buffer command resets the tag buffer. This clears the buffer of any current tags and reset the read index to 0. A Read Tag Multiple command must be issued to load new tags into the buffer.
FF
SOH
00
Length
2A
OpCode
1D
CRC
25
If Clear Tag Buffer or Get Tag Buffer is not used after a Read Tag Multiple to remove all tags, old tags will be left in the buffer. This means that if tags that have not been removed from the buffer are read again they will not be added to the buffer as second time, only their Read Count will be incremented.
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
Gen2 Tag Specific (2Dh)
The Gen2 Tag Specific command is a generic command providing an interface for operations proprietary to certain Gen2 tag silicon. The supported commands are grouped by tag silicon type, indicated by the Chip Type field. Each Chip Type may have multiple unique commands associated with it, indicated by the Sub Command field. Custom commands for the following Chip Types are supported:
Alien Higgs Silicon (Chip Type=0x01)
Alien Higgs 3 Silicon (Chip Type=0x05)
Command Set
119
120
Application Tag Commands
NXP G2X* Silicon (Chip Type=0x02)
NXP G2i* Silicon (Chip Type=0x07)
Impinj Monza 4 Silicon (Chip Type=0x08)
Hitachi Hibiki (Chip Type=0x06) [Deprecated]
Note
Most of the Gen2 Tag Specific commands can be used as an embedded
Tag Inventory With Embedded Operations
are noted in the specific Chip Type command definitions.
Note
The syntax for the Gen2 Tag Specific commands changed in M5e firmware v1.5. The legacy format is still supported but all new development should follow the syntax in this document. For info on the deprecated syntax please contact [email protected]
Alien Higgs Silicon (Chip Type=0x01)
Tags with Alien Higgs and Higgs-2 (only 96-bit EPC with no user memory versions)
Silicon support the following proprietary commands:
Alien Higgs Sub Commands
Sub Command value
0x01
0x03
Alien Higgs
Command
Note
Higgs and Higgs 2 custom commands are not supported as embedded
Tag Inventory With Embedded Operations
Tag Singulation/Select Functionality
Command Set
Application Tag Commands
Partial Load Image
Sub Command=0x01
If the first bit of Sub Command is 1 (Sub Command=0x01), the Gen2 Tag Specific command writes an EPC with a length of up to 96-bits, plus the Kill and Access passwords without locking in a single command.
The format for this command is as follows:
FF
SOH
18
Length
11
2D
OpCode
03 E8
Timeout (ms)
01
Chip Type
01
Sub
Command
22 33 44 55 66 77 88 99 AA BB CC 45 64
Tag ID CRC
00 00 00 00 00 00 00 00
Kill Password Access Password
Full Load Image
Sub Command=0x03
If the second bit of Sub Command is 1 (Sub Command=0x03), the Gen2 Tag Specific command will also modify the Lock bits (locking the tag according to the
The format is extended as follows:
FF
SOH
1C
Length
2D
OpCode
03 E8
Timeout (ms)
01
Chip Type
00 02 30 00 11 22 33 44 55 66
Lock Bits PC Word
77
Tag ID
88
03
Sub
Command
01 23 45 67 89 AB CD EF
Kill Password
99 AA BB CC ??
??
CRC
Access Password
The Lock Bits correspond to the Higgs TID Bank configuration bits with the same name and are shown in the following table:
Alien Higgs Lock Bits
Bit Number
Field Name>
15 14 13 12 11 10
X X X X X X
9
X
8
X
7
X
6
X
Command Set
121
Application Tag Commands
Default Values
Lock Values
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
5
APW
Lock
4
APW
P-lock
3
KPW
Lock
2
KPW
P-lock
0
1
0
1
0
1
0
1
1
EPC
Lock
0
1
0
EPC
Plock
0
1
Bit Number
Field Name
Default Values
Currently, only the first six bits of this field are used. A value of zero in each bit field keeps the corresponding memory segment unlocked. To lock any of the Kill and Access passwords or the EPC, temporarily or permanently, set the corresponding bit fields in the
Lock Bits word to 1. For additional information, refer to the Higgs Tags Application Notes
(Currently available at http://www.alientechnology.com/docs/
Load_Image_Application_Note_1.pdf - Contact Alien Technology for more details).
The PC Word field, in the table on the previous page, corresponds to the PC Word in the
Tag EPC memBank defined in the Gen2 Specification and is shown in the following table:
Alien Higgs PC Bits
15 14 13
PC Bits
12 11
X X X X X
10 9
RFU RFU
8
0 0 0
7 6
0 0
5
0
4
NSI
0
3
Bits
0
2 1 0
0 0 0
The PC Word in the Write Tag Specific command allows you to specify the NSI Bits and the length of the EPC that you want to write into the tag. The RFU bits are always zero and the PC Bits are determined by the EPC length as specified in the Gen2 Specification and the Higgs Tags Application Notes.
To use the extended format of the Gen2 Tag Specific command but keep the NSI bits intact, set option=0x03. This signals the reader to ignore the NSI bits of the PC Word sent to the reader along with the command.
In the example on the previous page, after the execution of the Gen2 Tag Specific command, the reader writes the 96-bit EPC 0x112233445566778899AABBCC, the Kill
122
Command Set
Application Tag Commands
Password 0x01234567, the Access Password 0x89ABCDEF into the tag without changing the NSI bits of the tag and locks the EPC memBank.
However, to access and write the NSI bits into the tag, set the third bit of the option field to
1 (option=0x07). In the example, if option is set to 0x07, the NSI bits are overwritten by zeros.
The following table summarizes the option field values and the action that is taken:
1
1
0
0
1
1
Bit
2
0
0
0
0
1
1
1
1
1
0
0
Number
0
0
1
0
1
0
1
0
1
Action
Invalid Value
Gen2 Tag Specific
without locking and without NSI bits being overwritten
Invalid Value
Gen2 Tag Specific
with locking and without NSI bits being overwritten
Invalid Value
Gen2 Tag Specific
without locking and with NSI bits being overwritten by zeros
Invalid Value
Gen2 Tag Specific
with locking and with NSI bits being overwritten by values that you specify
Alien Higgs 3 Silicon (Chip Type=0x05)
Tags with Alien Higgs 3 Silicon support the following proprietary commands as specified in the
Alien Technology Higgs 3 IC Custom Commands Application Note - Sept. 2008.
(please contact Alien for further details).
Alien Higgs3 Sub Commands
Sub Command value
0x0001
0x0003
Alien Higgs3
Command
Command Set
123
Application Tag Commands
Sub Command value
0x0009
Alien Higgs3
Command
FastLoadImage
Sub Command=0x0001
This command writes all of the following data to the Higgs3 tags in a single command,
thereby reducing the tag programming time compared to the use of
or multiple
commands.
Access Passwords
Kill Password
EPC Data (96 bits only)
!
C A U T I O N !
!
The FastLoadImage command automatically erases the content of all
User Memory. If this is undesirable then use the
commands.
124
Command Set
Application Tag Commands
FastLoadImage Command Fields
Field
Length
OpCode
Time Out
Chip Type
Option
Sub Command
[Address, Data
Length, Data]
Current Access
Password
Value
0x1E
0x2D
[2 bytes]
0x05
[1 byte]
0x0001
[n bytes]
Description
Number of bytes in the command following the OpCode.
Gen2 Tag Specific Command.
Command timeout in milliseconds.
Alien Higgs3.
• bit 6 (x1xx xxxx | 0x40) must be set, indicating a 2-byte sub
command follows this byte, and before the remaining Tag
FastLoadImage
The remaining fields from the
Note:
Optional depending on the value of Select Option.
Kill Password
New Access
Password
PC Word
EPC Data
[4 bytes]
[4 bytes]
[4 bytes]
The Access Password for the tag. If Access Password is currently set and the tag locked, the Access Password must be passed to allow writing.
The new Kill Password to be written to Reserved Memory
The new Access Password to be written to Reserved Memory
[2 bytes]
[12 bytes]
The value of the PC Word to be written to EPC Memory
The 96 bit EPC value to be written to the tag.
An example FastLoadImage single tag command is:.
FF
SOH
25
Length
2D
OpCode
03 E8
Timeout (ms)
05
Chip
Type
44
Option
00 01 00 00 00 20
Sub
Cmd
Select Data Address
10
Select
Length
11 22
Selct
Data
11 11 22 22 00 00 00 00 11 22 33 44 XX XX
Current Access Pwd Kill Password New Access Password PC Word
(12 bytes)
EPC Data
??
??
CRC
The response to the FastLoadImage command is an ACK with the written EPC data. The
Command Set
125
Application Tag Commands format of the response is:
FF
SOH
09
Length
2D
OpCode
00
Status
00 05
Chip
Type
44
Option
00 01
Sub
Cmd
XX XX ...
EPC Data
??
CRC
??
FastLoadImage embedded in a Read Tag Multiple takes the following form:
FF
SOH
19
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 38
Select
Data
Length
(bits)
Select
Data
01
Embd
Cmd
Count
1F
Embd
Cmd
Length
2D
Embd
Cmd
OpCode
00 00
05
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
00 01
Sub Cmd
11 11 22 22 00 00 00 00 11 22 33 44 XX XX
Current Access Pwd Kill Password New Access Password PC Word
(12 bytes)
EPC Data
??
??
CRC
LoadImage
Sub Command=0x0003
This command writes all of the following data to the Higgs3 tags in a single command, thereby reducing the tag programming time compared to the use of multiple
Reserved Memory
EPC Memory
User Memory
126
Command Set
Application Tag Commands
LoadImage Command Fields
Field
Length
OpCode
Time Out
Chip Type
Option
Sub Command
[Address, Data
Length, Data]
Current Access
Password
Value
0x5E
0x2D
[2 bytes]
0x05
[1 byte]
0x0003
[n bytes]
Description
Number of bytes in the command following the OpCode.
Gen2 Tag Specific Command.
Command timeout in milliseconds.
Alien Higgs3.
• bit 6 (x1xx xxxx | 0x40) must be set, indicating a 2-byte sub
command follows this byte, and before the remaining Tag
LoadImage
The remaining fields from the
Note:
Optional depending on the value of Select Option.
Kill Password
New Access
Password
PC Word
EPC Data and
User Data
[4 bytes]
[4 bytes]
[4 bytes]
The Access Password for the tag. If Access Password is currently set and the tag locked, the Access Password must be passed to allow writing.
The new Kill Password to be written to Reserved Memory
The new Access Password to be written to Reserved Memory
[2 bytes]
[76 bytes]
The value of the PC Word to be written to EPC Memory
The 96 bit EPC value to be written to the tag.
Note:
The specific mapping of these 76 bytes to the tag EPC or
User Memory locations is defined in the
Alien Technology
Higgs 3 IC Custom Commands Application Note - Sept. 2008.
An example LoadImage single tag command is:.
FF
SOH
XX
Length
2D
OpCode
03 E8
Timeout (ms)
05
Chip
Type
44
Option
00 03 00 00 00 20
Sub
Cmd
Select Data Address
10
Select
Length
11 22
Selct
Data
11 11 22 22 00 00 00 00 11 22 33 44 XX XX
Current Access Pwd Kill Password New Access Password PC Word
(76 bytes)
EPC + User
Data
??
??
CRC
Command Set
127
Application Tag Commands
The response to the LoadImage command is an ACK with the written EPC data. The format of the response is:
FF
SOH
XX
Length
2D
OpCode
00
Status
00 05
Chip
Type
44
Option
00 03
Sub
Cmd
XX XX ...
EPC Data
LoadImage embedded in a Read Tag Multiple takes the following form:
??
CRC
??
FF
SOH
XX
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 38
Select
Data
Length
(bits)
Select
Data
01
Embd
Cmd
Count
5F
Embd
Cmd
Length
2D
Embd
Cmd
OpCode
00 00
05
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
00 03
Sub Cmd
11 11 22 22 00 00 00 00 11 22 33 44 XX XX
Current Access Pwd Kill Password New Access Password PC Word
(76 bytes)
EPC + User
Data
??
??
CRC
BlockReadLock
Sub Command=0x0009
This command allows four-word blocks of User Memory to be read locked. Once read locked the correct Access Password will be required to read the contents of the locked
.
128
Command Set
Application Tag Commands
BlockReadLock Command Fields
Field
Length
OpCode
Time Out
Chip Type
Option
Sub Command
[Address, Data
Length, Data]
Current Access
Password
Value
0x09
0x2D
[2 bytes]
0x05
[1 byte]
0x0009
[n bytes]
[4 bytes]
Command Lock
Bits
[1 byte]
Description
Number of bytes in the command following the OpCode.
Gen2 Tag Specific Command.
Command timeout in milliseconds.
Alien Higgs3.
• bit 6 (x1xx xxxx | 0x40) must be set, indicating a 2-byte sub
command follows this byte, and before the remaining Tag
BlockReadLock
The remaining fields from the
Note:
Optional depending on the value of Select Option.
The Access Password for the tag. If Access Password is currently set and the tag locked, the Access Password must be passed to allow writing.
Setting a bit value = 1 locks the corresponding User Memory Words.
The least significant bit is bit0: bit7=1 Locks User words 0 thru 3 bit6=1 Locks User words 4 thru 7 bit5=1 Locks User words 8 thru 11 bit4=1 Locks User words 12 thru 15 bit3=1 Locks User words 16 thru 19 bit2=1 Locks User words 20 thru 23 bit1=1 Locks User words 24 thru 27 bit0=1 Locks User words 28 thru 31
Note:
Depending on the tag memory configuration all 32 Words of
User memory may not be available.
An example BlockReadLock single tag command is:.
FF
SOH
25
Length
2D
OpCode
03 E8
Timeout (ms)
05
Chip
Type
44
Option
00 09 00 00 00 20
Sub
Cmd
Select Data Address
10
Select
Length
11 22
Selct
Data
Command Set
129
Application Tag Commands
11 11 22 22
Current Access Pwd
XX
Lock
Bits
??
??
CRC
The response to the BlockReadLock command is an ACK. The format of the response is:
FF
SOH
04
Length
2D
OpCode
00
Status
00 05
Chip
Type
44
Option
00 09
Sub
Cmd
??
CRC
??
BlockReadLock embedded in a Read Tag Multiple takes the following form:
FF
SOH
XX
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 38
Select
Data
Length
(bits)
Select
Data
01
Embd
Cmd
Count
0B
Embd
Cmd
Length
2D
Embd
Cmd
OpCode
00 00
05
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
00 09
Sub Cmd
11 11 22 22
Current Access Pwd
XX
Lock
Bits
??
??
CRC
NXP G2X* Silicon (Chip Type=0x02)
Tags with NXP Silicon support the following proprietary commands as specified in the
SL31CS1202 G2XM UCode Functional Specification
(please contact NXP for details):
130
Command Set
Application Tag Commands
NXP Sub Commands
Sub Command value
0x0001
0x0002
0x0003
0x0004
0x0005
NXP Command
All NXP-proprietary commands contain the following fields:
Command Set
131
132
Application Tag Commands
NXP Common Fields
Length
OpCode
Timeout
Field
Chip Type
| Select Option
[1 byte]
Sub Command
| Select [Address,
Data Length, Data]
[2 bytes]
[n bytes]
Access Password
[1 byte]
0x2D
[2 bytes]
[1 byte]
[4 bytes]
Value Notes
Ignored when used as an embedded command for
• 0x02 - NXP G2X*
• 0x07 - NXP G2i*
• bit 6 (x1xx xxxx | 0x40) must be set, indicating a 2-byte sub command follows this byte, and before the remaining
Note:
Optional depending on the value of Select Option.
• Must be non-zero for Set/Reset
ReadProtect and Change EAS
does not take the
Access Password field.
In addition to the common fields some commands have additional required fields as indicated below.
Set ReadProtect
The NXP command Set ReadProtect causes the commands Read, Write, Kill, Lock,
Access, Set ReadProtect, Change EAS, EAS Alarm and Calibrate to be disabled until a
Command Set
Application Tag Commands
“Reset ReadProtect” is received. This command uses only the common fields and is invoked with the following command:
FF
SOH
10
Length
2D
OpCode
03 E8
Timeout (ms)
02
Chip
Type
44
Option
00 01 00 00 00 78
Sub
Cmd
Select Data Address
08
Select
Length
34
Selct
Data
11 22 33 44 ??
??
Access Password CRC
The response to the Set ReadProtect command is a simple ACK with standard status:
FF
SOH
04
Length
2D
OpCode
00
Status
00 02
Chip
Type
44
Option
00 01
Sub
Cmd
??
CRC
??
Set ReadProtect embedded in a Read Tag Multiple take the following form:
FF
SOH
1C
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 34
Select
Data
Length
(bits)
Select
Data
01 0A
Embd
Cmd
Count
Embd
Cmd
Length
2D
Embd
Cmd
OpCode
00 00
02
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
00 01
Sub Cmd
11 22 33
Access Password)
44
??
CRC
??
Reset ReadProtect
The NXP command Reset ReadProtect restores normal operation to a tag which is in
ReadProtect mode. This command uses only the common fields and is invoked with the following command:
Command Set
133
Application Tag Commands
Note
Only the G2i command can be performed as an embedded operation in a
Read Tag Multiple. The G2x version cannot.
FF 10
SOH Length
2D
OpCode
03 E8
Timeout (ms)
02
Chip
Type
44
Option
00 02 00 00 00 78
Sub
Cmd
Select Data Address
08
Select
Length
34
Selct
Data
11 22 33 44 ??
??
Access Password CRC
The response to the Reset ReadProtect command is a simple ACK with standard status:
FF
SOH
04
Length
2D
OpCode
00
Status
00 02
Chip
Type
44
Option
00 02
Sub
Cmd
??
CRC
??
Reset ReadProtect embedded in a Read Tag Multiple take the following form:
FF
SOH
1C
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 34
Select
Data
Length
(bits)
Select
Data
01 0A 2D
Embd
Cmd
Count
Embd
Cmd
Length
Embd
Cmd
OpCode
00 00
02
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
00 02
Sub Cmd
11 22 33
Access Password)
44
??
CRC
??
Change EAS
The NXP command Change EAS sets or resets the EAS system bit. When set, the tag will return an alarm code if an “EAS Alarm” command is received. This command takes an additional field:
134
Command Set
Application Tag Commands
Change EAS
(1 byte: 0x01=Set EAS; 0x02=Reset EAS)
It is invoked with the following command:
FF
SOH
11
Length
2D
OpCode
03 E8
Timeout (ms)
02
Chip
Type
44
Option
00 03 00 00 00 78
Sub
Cmd
Select Data Address
08
Select
Length
34
Selct
Data
11 22 33 44
Access Password
01
EAS
??
??
CRC
The response to the ChangeEAS command is a simple ACK with standard status:
FF
SOH
04
Length
2D
OpCode
00
Status
00 02
Chip
Type
44
Option
00 03
Sub
Cmd
??
CRC
??
ChangeEAS embedded in a Read Tag Multiple take the following form:
FF
SOH
1C
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 34
Select
Data
Length
(bits)
Select
Data
01 0B
Embd
Cmd
Count
Embd
Cmd
Length
2D
Embd
Cmd
OpCode
00 00
02
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
00 01
Sub Cmd
11 22 33
Access Password)
44
01
EAS
??
CRC
??
EAS Alarm
The NXP command EAS Alarm causes the tag to return coded information, but only when the tag has its EAS system bit set. This command requires several fields in addition to the common fields
Divide Ratio as Per Gen2 (DR)
(1 byte: Current fixed to 0x01, M5e and M5e-C only support DR=64/3)
Miller Cycles (M)
(1 byte: 0x01, M=2; 0x02, M=4;or 0x03, M=8)
Note:
This value of M must be the same as the value set in
Set Protocol Configuration (9Bh)
Command Set
135
136
Application Tag Commands
TrExt as Per Gen2
(1 byte: Current fixed to 0x01, M5e and M5e-C only support extended Pilot Tone)
It is invoked with the following command, it does not support tag singulation:
FF
SOH
09
Length
2D
OpCode
03 E8
Timeout (ms)
02
Chip
Type
4o
Option
00 04
Sub
Cmd
01
DR M
02 01
TrExt
??
??
CRC
The response to the EAS Alarm command contains 8 bytes of EAS Alarm Data, only if
Status=0x0000. The format of the response is:
FF
SOH
0A
Length
2D
OpCode
00
Status
00 02
Chip
Type
44
Option
00 04
Sub
Cmd
[8 bytes]
[EAS Alarm
Data]
??
CRC
??
Note
EASAlarm cannot be embedded in Read Tag Multiple.
Command Set
Application Tag Commands
Calibrate
The NXP command Calibrate causes the tag to return a random data pattern that is useful in some frequency spectrum measurements.
Calibrate can only be sent when the tag is in the Secured state, when the access password is non-zero. This command uses only the common fields and is invoked with the following command.
FF 10 2D
SOH Length OpCode
03 E8
Timeout (ms)
02
Chip
Type
44
Option
00 05 00 00 00 78
Sub
Cmd
Select Data Address
08 34
Select
Length
Selct
Data
11 22 33 44 ??
??
Access Password CRC
The response to the Calibrate command contains 64 bytes of Calibrate Data, only if
Status=0x0000. The format of the response is:
FF
SOH
09
Length
2D
OpCode
00
Status
00 02
Chip
Type
44
Option
00 05 [64 bytes]
Sub
Cmd
[Calibrate
Data]
??
CRC
??
Calibrate embedded in a Read Tag Multiple take the following form:
FF
SOH
19
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 34
Select
Data
Length
(bits)
Select
Data
01 0A 2D
Embd
Cmd
Count
Embd
Cmd
Length
Embd
Cmd
OpCode
00 00
02
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
00 05
Sub Cmd
11 22 33
Access Password)
44
??
CRC
??
Note
If the tag is a G2XL without User Memory the
Calibrate Data
response field will contain 64 bytes of ‘00’.
NXP G2i* Silicon (Chip Type=0x07)
Tags using the NXP G2i Silicon (SL3S1203_1213), please contact NXP for further details, support all the commands defined for
NXP G2X* Silicon (Chip Type=0x02)
, with the caveats as noted in the command descriptions. In addition the following custom commands is G2i* only.
Command Set
137
Application Tag Commands
ChangeConfig
The ChangeConfig command is used to toggle the bits of the G2i* tag’s ConfigWord (see
ConfigWord to Command Bit Address Map
table). Specify a ‘1’ in the desired bit location of
the Config Data word of the command in order to toggle that bit.
Note
Different version of the G2i* tags support different features. See tag data sheet for specific bits supported.
7
6
5
4
The ChangeConfig command can ONLY be sent in the Secured state, i.e. requires a nonzero password. Caution should be used when embedding ChangeConfig in a
Inventory With Embedded Operations
command. Since this command toggles the specified bits, if the tag responds twice (or an even number of times) during an inventory round the end result will be no change.
ConfigWord to Command Bit Address Map
G2i* ConfigWord Bit
Address (Hex)
Toggle Bit Description
11
10
9
8
15
14
13
12
Config Data Bit
Address
(LSB=bit 0)
3
0x200
0x201
0x202
0x203
0x204
0x205
0x206
0x207
0x208
0x209
0x20A
0x20B
0x20C
Tamper Alarm Flag (read only)
External Supply Flag Digital Input (read only)
RFU
RFU
Invert Digital Output (reset at power up)
Transparent Mode On/Off (reset at power up)
Transparent Mode data/raw (reset at power up)
Conditional Read Range Reduction (permanently stored in tag memory)
Conditional Range Redcution Open/Short (permanently stored in tag memory)
Maximum Backscatter Strength (permanently stored in tag memory)
Digital Output (permanently stored in tag memory)
Read Range Reduction On/Off (permanently stored in tag memory)
Read Protect User Memory (permanently stored in tag memory)
138
Command Set
Application Tag Commands
1
0
2
Config Data Bit
Address
(LSB=bit 0)
G2i* ConfigWord Bit
Address (Hex)
0x20D
0x20E
0x20F
Toggle Bit Description
Read Protect EPC Bank (permanently stored in tag memory)
Read Protect TID (permanently stored in tag memory)
PSF Alarm Flag (permanently stored in tag memory)
Command Set
139
Application Tag Commands
NXP G2i* Command Fields
Length
OpCode
Timeout
Field
[1 byte]
0x2D
[2 bytes]
Value Notes
Chip Type
| Select Option
0x07
[1 byte]
Sub Command
Access Password
| Select [Address,
Data Length, Data]
[n bytes]
RFU
Config Data
[2 bytes]
[4 bytes]
0x00
[2 bytes]
Ignored when used as an embedded command for
Tag Inventory With Embedded Operations
0x07 - NXP G2i*
• bit 6 (x1xx xxxx | 0x40) must be set, indicating a 2-byte sub command follows this
byte, and before the remaining Tag
Must be non-zero for ChangeConfig. If zero the
ConfigWord will not be changed.
The remaining fields from the Tag Singulation
Note:
Optional depending on the value of
Select Option.
RFU
Toggle memory bits as defined by ConfigWord to Command Bit Address Map
• ‘1’ - Toggle memory bit
• ‘0’ - Leave memory alone
An example ChangeConfig single tag command is:.
FF
SOH
10
Length
2D
OpCode
03 E8
Timeout (ms)
07
Chip
Type
44
Option
00 07 11 22 33 44 00 00 00 78
Sub
Cmd
Access Password Select Data Address
08 34
Select
Length
Selct
Data
00
RFU
00 00
Config Data
??
??
CRC
The response to the ChangeConfig command contains the new value of the tag’s
ConfigWord after the Config Data toggle bits have been appled. The format of the
140
Command Set
Application Tag Commands response is:
FF
SOH
09
Length
2D
OpCode
00
Status
00 07
Chip
Type
44
Option
00 07
Sub
Cmd
00 00
New Config-
Word Value
??
CRC
??
ChangeConfig embedded in a Read Tag Multiple takes the following form:
FF
SOH
19
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 34
Select
Data
Length
(bits)
Select
Data
01 09
Embd
Cmd
Count
Embd
Cmd
Length
2D
Embd
Cmd
OpCode
00 00
07
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
00 07
Sub Cmd
00
RFU
00 00
Config Data
??
CRC
??
Impinj Monza 4 Silicon (Chip Type=0x08)
Tags with the Impinj Monza 4 chip support custom functionality providing protection of data through public and private data profiles and the use of short range reading options.
These are controlled through custom commands as defined by the Impinj Monza 4 datasheet (IPJ_Monza4Datasheet_20101101.pdf (please contact Impinj for more details.
QT Read/Write
The QT command controls the switching of Monza 4QT between the Private and Public profiles. The tag MUST be in the Secured state to succeed.
Command Set
141
142
Application Tag Commands
Length
OpCode
Timeout
Field
Sub Command
Access Password
| Select [Address,
Data Length, Data]
Control Byte
0x0000
[4 bytes]
[n bytes]
0xX0
Payload
Impinj Monza 4QT Command Fields
Value
[1 byte]
0x2D
[2 bytes]
Chip Type
| Select Option
0x08
[1 byte]
[2 bytes]
Notes
Ignored when used as an embedded command for
Inventory With Embedded Operations
0x08 - Impinj Monza 4QT bit 6 (x1xx xxxx | 0x40) must be set, indicating a 2-byte sub command follows this byte, and before the remaining
• 0x0000 - QT Read/Write
• Must be non-zero for QT Read/Write
The remaining fields from the
Note:
Optional depending on the value of Select Option.
Only the 4 most significant bits are used, as follows:
Bit 7 (MSB) - Read/Write bit
• 0 = read the QT control bits in cache
• 1 = write the QT control bits
Bit 6 - Persistence bit
• 0 = write the QT Control to volatile memory
• 1 = write the QT Control to nonvolatile memory
Bits 5 and 4 - RFU, currently ignored by tag
Controls the QT functionality. These bits are ignored when the Read/Write bit =0.
Bit 15 (MSB) - QT_SR
• 0 = Tag does not reduce range
• 1 = Tag reduces range if in or about to be in OPEN or
SECURED state.
Bit 14 - QT_MEM
• 0 = Tag uses Private Memory Map
• 1 = Tag uses Public Memory Map
Bits 13:0 - RFU
Command Set
Application Tag Commands
An example QT Read/Write single tag command is:.
FF 09
SOH Length
2D
OpCode
03 E8
Timeout (ms)
08
Chip
Type
40
Option
00 00
Sub
Cmd
00
Control
Byte
00 00 ??
??
Payload CRC
The response to the QT Read/Write command contains the payload read or written as specified by the control byte’s Read/Write bit. The format of the response is:
FF
SO
H
06
Length
2D
OpCode
00
Status
00 08
Chip
Type
40
Option
00 00 00 00 ??
??
Sub
Cmd
Payload CRC
QT Read/Write embedded in a Read Tag Multiple takes the following form:
FF
SOH
1A
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 34
Select
Data
Length
(bits)
Select
Data
01 08
Embd
Cmd
Count
Embd
Cmd
Length
2D
Embd
Cmd
OpCode
00 00
08
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
00 00
Sub Cmd
00
Control
Byte
00 00
Payload
??
CRC
??
IDS SL900A (Chip Type=0x0A)
Please see the
MercuryAPI Programmers Guide | Level 2 | Advanced Tag Operations
section for the programming interface supporting IDS SL900A “Cool Log” functionality.
For the serial protocol specification for these tags please contact ThingMagic Support.
Hitachi Hibiki (Chip Type=0x06) [Deprecated]
Tags with Hitachi Hibiki Silicon support the following proprietary commands as specified in the
Secure RFID Protocol Specification v.1.34 June 29, 2007.
(please contact Hitachi for details).
Please contact ThingMagic Support for assistance using Hibiki operations.
Command Set
143
144
Application Tag Commands
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_PROTOCOL_INVALID_ADDRESS – 409h
FAULT_GENERAL_TAG_ERROR – 40Ah
FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
FAULT_ANTENNA_NOT_CONNECTED – 503h
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
BlockWrite (2Dh)
BlockWrite is a Gen2 2.0 Optional command. On tags which support this command, it provides faster writing of data to a tag by writing more than one word at a time.
The BlockWrite command takes the following fields:
Command Set
Application Tag Commands
BlockWrite Command Fields
Length
OpCode
Timeout
Field Value
[1 byte]
0x2D
[2 bytes]
Chip Type
| Select Option
0x00
[1 byte]
Notes
Number of bytes in the command following the OpCode.
BlockWrite
Ignored when used as an embedded command for
Tag Inventory With Embedded Operations
Standard Gen2 2.0 tags bit 6 (x1xx xxxx | 0x40) must be set, indicating a 2-byte sub
command follows this byte, and before the remaining Tag Singulation Fields
• 0x00C7 - BlockWrite
The tag’s Access Password for writing to write locked memory
The remaining fields from the
Note:
Optional depending on the value of Select Option.
Sub Command
Access Password
| Select [Address,
Data Length, Data]
WriteFlags
MemoryBank
0x00C7
[4 bytes]
[n bytes]
0x00
[1 byte]
WordPointer
WordCount
Data
[4 bytes]
[1 bytes]
[2*WordCount bytes]
Reserved for future use.
Memory bank who’s data will be erased. Standard Gen2 field values:
• 0x00 = Reserved
• 0x01 = EPC
• 0x02 = TID
• 0x03 = User
Starting, zero-based, 16-bit word address of the MemoryBank to be written.
Number of 16-bit words to be written.
Data to be written
An example BlockWrite single tag command is:.
FF
SOH
09
Length
2D
OpCode
03 E8
Timeout (ms)
00
Chip
Type
44
Option
00 C7
Sub
Cmd
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 34
Select
Data
Length
(bits)
Select
Data
Command Set
145
Application Tag Commands
00
Write
Flag
00
Mem
Bank
00
Word
Pointer
01
Word
Count
00 00
Data
??
CRC
??
The response to the BlockWrite command is an ACK. The format of the response is:
FF 04
SOH Length
2D
OpCode
00
Status
00 00
Chip
Type
44
Option
00 C7
Sub
Cmd
??
CRC
??
BlockWrite embedded in a Read Tag Multiple takes the following form:
FF
SOH
1A
Length
22
OpCode
04
Options
(EPC Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 78
Select Data Address
(bits)
08 34
Select
Data
Length
(bits)
Select
Data
01
Embd
Cmd
Count
10 2D
Embd
Cmd
Length
Embd
Cmd
OpCode
00 00 00
Embd Cmd
Timeout
(Not Used)
Chip
Type
44
Option
00 C7
Sub Cmd
00
Write
Flag
00
Mem
Bank
00
Word
Pointer
01
Word
Count
00 00
Data
??
CRC
??
BlockPermaLock (2Eh)
BlockPermaLock is a Gen2 2.0 Optional command. On tags which support this command, it allows User Memory to be selectively, permanently write-locked in individual
sub-portions. Compare BlockPermaLock with standard
locking entire memory banks and allows for no permanent locking.. The block-size is tagspecific. For example Alien Higgs3 tags support 4 word blocks.
The BlockPermaLock command takes the following fields:
146
Command Set
Application Tag Commands
Field
Length
OpCode
Time Out
Chip Type
| Select Option
Sub Command
Access Password
Value
[1 byte]
0x2E
[2 bytes]
0x00
[1 byte]
0x01
[4 bytes]
| Select
[Address, Data
Length, Data]
RFU
Read/Lock
[n bytes]
BlockPermaLock Command Fields
Description
Number of bytes in the command following the OpCode.
Gen2 Optional Command.
Command timeout in milliseconds.
Gen2 2.0 Tags with BlockPermalock support bit 6 (x1xx xxxx | 0x40) must be set, indicating a 1-byte sub command follows
this byte, and before the remaining Tag Singulation Fields
BlockPermaLock
The Access Password for the tag.
Note:
Do not include password if Select Option = 0xX0.
The remaining fields from the
Note:
Optional depending on the value of Select Option.
MemoryBank
BlockPointer
BlockRange
Mask
0x00
[1 byte]
0x03
[4 bytes]
[1 byte]
[2*Block-
Range bytes]
Reserved for future use.
Only the Least Significant Bit is used:
• 0x00 = Return the PermaLock status of the blocks specified.
• 0x01 = PermaLock the blocks specified
Memory bank who’s blocks will be locked. Currently only User Memory is supported.
The starting address for Mask, in units of 16 blocks. For example, BlockPtr =
0x00 indicates block 0, BlockPtr = 0x01 indicates block 16, BlockPtr = 0x02 indicates block 32. Depending on the tag memory configuration all 32 Words of
User memory may not be available.
Note:
For Higgs3 tags this value must always be 0x00
The range of Mask, starting at BlockPointer and ending (16×BlockRange)–1 blocks later.
Note:
For Higgs3 tags this value must always be 0x01
Memory blocks to PermaLock. Mask depends on the Read/Lock bit as follows:
• Read/Lock = 0: Do not include the Mask field.
• Read/Lock = 1: Mask is 16×BlockRange bits. The Mask bits shall be ordered from lower-order block to higher (i.e. if BlockPtr = 00h then the mostsignificant Mask bit refers to block 0).
– Mask bit = 0: No change to block.
– Mask bit = 1: Permalock the corresponding memory block.
Command Set
147
Application Tag Commands
An example BlockPermaLock single tag command, locking Block 5, is:.
FF
SOH
1A
Length
2E
OpCode
03 E8
Timeout (ms)
00
Chip
Type
42
Option
01
Sub
Cmd
11 11 22
Access Passwords
22 00 00 00 00
Select Data Address
10
Select
Length
E2 00
Selct
Data
00
RFU
01
Read/
Lock
03
Mem
Bank
00 00 00 00
Block Ptr
01
Block
Range
04 00
Mask
??
CRC
??
The response to the BlockReadLock command contains the current (for just a read operation) or updated (for a lock operation) status of the memory blocks requested. The format of the response is:
FF
SOH
XX
Length
2E
OpCode
00
Status
00 42
Option
XX
Word
Count
XX XX ...
Tag’s Lock Response Mask
(2*BlockRange bytes)
??
CRC
??
The same BlockPermaLock embedded in a Read Tag Multiple takes the following form:
FF
SOH
21
Length
22
OpCode
02
Options
(TID Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 00
Select Data Address
(bits)
08 E2
Select
Data
Length
(bits)
Select
Data
01
Embd
Cmd
Count
0F
Embd
Cmd
Length
2E
Embd
Cmd
OpCode
00 00 00
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
01
Sub
Cmd
00
RFU
01
Read/
Lock
03
Mem
Bank
00 00 00 00
Block Ptr
01
Block
Range
04 00
Mask
??
??
CRC
148
Command Set
Application Tag Commands
BlockErase (2Eh)
BlockErase
is a Gen2 2.0 Optional command. On tags which support this command, it allows multiple words in any memory bank to be erased in a single operation.
The BlockErase command takes the following fields:
Command Set
149
150
Application Tag Commands
Field
Length
OpCode
Time Out
Chip Type
| Select Option
Sub Command
Access Password
Value
[1 byte]
0x2E
[2 bytes]
0x00
[1 byte]
0x00
[4 bytes]
| Select [Address, Data
Length, Data]
WordPointer
MemoryBank
[n bytes]
[4 bytes]
[1 byte]
WordCount [1 bytes]
BlockWrite Command Fields
Description
Number of bytes in the command following the OpCode.
Gen2 Optional Command.
Command timeout in milliseconds.
Gen2 2.0 Tags with BlockPermalock support bit 6 (x1xx xxxx | 0x40) must be set, indicating a 1-byte sub command follows this byte, and before the remaining
BlockErase
The Access Password for the tag.
Note:
Do not include password if Select Option = 0xX0.
The remaining fields from the
Note:
Optional depending on the value of Select Option.
Starting, zero-based, 16-bit word address of the MemoryBank to be erased.
Memory bank who’s data will be erased. Standard Gen2 field values:
• 0x00 = Reserved
• 0x01 = EPC
• 0x02 = TID
• 0x03 = User
Number of 16-bit words to be erased.
An example BlockErase single tag command is:.
FF 1A
SOH Length
2E
OpCode
03 E8
Timeout (ms)
00
Chip
Type
42
Option
00
Sub
Cmd
11 11 22
Access Passwords
22 00 00 00 00
Select Data Address
10
Select
Length
E2 00
Selct
Data
00 00 00
Address
02 01
Mem
Bank
01
Word
Count
??
CRC
??
The response to the BlockErase command is an ACK. The format of the response is:
FF
SOH
XX
Length
2E
OpCode
00
Status
00 ??
CRC
??
Command Set
Application Tag Commands
The same BlockErases embedded in a Read Tag Multiple takes the following form:
FF
SOH
21
Length
22
OpCode
02
Options
(TID Mem)
00 04
Search
Flags
03 E8
Timeout
11 22 33
Access Password
44 00 00 00 00
Select Data Address
(bits)
08 E2
Select
Data
Length
(bits)
Select
Data
01
Embd
Cmd
Count
0F
Embd
Cmd
Length
2E
Embd
Cmd
OpCode
00 00
00
Embd Cmd
Timeout
(Not Used)
Chip
Type
40
Option
00
Sub
Cmd
00 00 00
Address
02 01
Mem
Bank
01
Word
Count
??
CRC
??
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_PROTOCOL_INVALID_ADDRESS – 409h
FAULT_GENERAL_TAG_ERROR – 40Ah
FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
FAULT_ANTENNA_NOT_CONNECTED – 503h
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
Command Set
151
Set Application Commands
Set Application Commands
The Set commands are used to set configurable values in the firmware. Since the values are not stored in flash, these values are reset to the default values whenever the application firmware is restarted. The application responds with a fault code / ACK to all commands.
The following table lists the Application Set commands:
Set Application Commands
0x95
0x96
0x97
0x98
0x91
0x92
0x93
0x94
0x99
0x9A
0x9B
OpCode Command Name
Set Current Tag Protocol (93h)
Set Protocol Configuration (9Bh)
Bootloader
N
N
N
N
N
N
N
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
App Firmware
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
152
Command Set
Set Application Commands
Set Antenna Port (91h)
The Set Antenna Port command supports multiple options (Option=0x01 is not supported) each setting the different aspects of the modules antenna configuration.
Please read all the details of various options for setting antenna configuration parameters before using the command.
Set Single Tag Operations Antennas
The Set Antenna Port command, using the syntax without an Option field and when
Option=0x00, sets the logical transmit (TX) and receive (RX) antennas to be used for
, etc.).
The old syntax, with no Option parameter simply takes a 1 byte TX and 1 byte RX logical antenna number. Valid TX and RX values range from 1 to 8 (assuming two four port multiplexers are used).
FF
SOH
02
Length
91
OpCode
01
TX Ant Num
01
Rx Ant Num
70
CRC
3B
All other settings will result in an error.
Using the new syntax with Option = 0x00 duplicates the functionality of the old syntax:
Set Single Tag Ops Antennas Command Fields (Option = 0x00)
Field
Length
OpCode
Option
TX Port
RX Port
Value
[1 byte]
0x91
0x00
[1 byte]
[1 byte]
Description
Number of bytes after OpCode
Set Antenna Port
Set TX / RX Antennas for Single Tag Operations
Specifies which logical antenna to be used for Transmitting
Specifies which logical antenna to be used for Receiving
Note
If a single tag operations antenna is not specified the default is a single bistatic antenna on TX=1/RX=2.
Command Set
153
154
Set Application Commands
Set Multi-Antenna Search Configuration
Option = 0x02 allows the order antennas will be used during a multi-antenna search with
to be specified. The multi-antenna search allows mixing of monostatic and bistatic configurations and ports can be duplicated in the search list if it is desirable to return to some antennas more often than others. The number of antennas available for use and the specific physical to logical port mapping is based on the
GPIO as Antenna Switch
.
Set Logical Antennas Command Fields (Option = 0x02)
Field Value Description
Length
OpCode
Option
TX/RX Logical
Antenna
[1 byte]
0x91
0x02
[2 bytes]
Number of bytes after OpCode
Set Antenna Port
The logical antenna search configuration to follow.
One or multiple 2 byte pairs indicating the logical TX and RX antennas to use. The order specified indicates the order antennas will be used in a multi-antenna search.
Note:
Monostatic and bistatic logical antennas can be mixed in the same search list and entries can be repeated.
Note:
Repeat the TX/RX Logical Antenna field for each logical antenna being configured for the search list in the desired search order.
Note
If a search configuration is not specified the default is a single bistatic antenna on TX=1/RX=2.
Set Antenna’s Power and Settling Time
Option =0x03 and 0x04 allows the power and settling time (only option=0x04) for each logical antenna to be set. The order the antennas settings are defined does not affect search order.
Note
Settling time
is the time between once the control lines switch to the next antenna setting and RF turns on for operations on that port. This allows time for external multiplexer’s to fully switch to the new port before a signal is sent, if necessary.
Default value is 0
.
Command Set
Set Application Commands
!
C A U T I O N !
!
When the TX power for a logical antenna is defined using this command the power setting specified for each port specified will be used for
all
operations, overriding the default, module wide, value set in
and
. If a logical antenna’s power is not set with this command then it will use the module-wide value set in those commands.
Set Antenna’s Power and Settling Command Fields (Option = 0x03 or 0x04)
Field Value Description
Length
OpCode
Option
TX Logical
Antenna
Read Power
Write Power
Settling Time
[1 byte]
0x91
0x03 or 0x04
[1 byte]
[2 bytes]
[2 bytes]
[2 bytes]
Number of bytes after OpCode
Set Antenna Port
0x03 indicates only the Power setting will be provided
0x04 indicates Power and Settling time will be provided
Specifies the TX antenna the following settings are to be applied.
The TX read power, in centi-dBm, to be used when this antenna is active for read operations.
The TX write power, in centi-dBm, to be used when this antenna is active for write operations.
The settling time, in microseconds, to be used when this antenna is active. (Only passed when Option=0x04)
Note:
Repeat the TX Logical Antenna, Power and Settling Time (if Option=0x04) fields for each logical antenna being configured for transmitting.
Note
When setting parameters for multiple logical antennas all the logical antennas requiring non-default values must be set in one command. If this command is sent twice, only the logical antenna settings in the second invocation will be used.
Note
Commands to set up power and settling time (Option=0x03 and 0x04) do not affect the
Set Multi-Antenna Search Configuration
Command Set
155
Set Application Commands
Set Read TX Power (92h)
The Set Read TX Power command sets the default, module-wide, power level to be used for reading tags. The power is specified as a 16-bit value in centi-dBm. For instance, a power of 25 dBm is 2500 centi-dBm, which is 0x09C4.
FF
SOH
02
Length
92
OpCode
09 C4
Power in centi-dBm
48
CRC
9D
Note
Power settings for individual logical antenna ports specified in
156
Command Set
Set Application Commands
Set Current Tag Protocol (93h)
To select a protocol, send the Set Current Tag Protocol code to the reader. A table of valid protocol codes is found in
Get Current Tag Protocol (63h)
. The following example sets the protocol to GEN2:
FF
SOH
02
Length
93
OpCode
00 05
Current Protocol
51
CRC
7D
Only protocols that are enabled in the reader are available. These protocols are listed in
the version information for the application, described in
Get Boot Loader/Firmware Version
Note
Changing protocol parameters manually using
Set Protocol Configuration (9Bh)
will maintain their value across changes in the current protocol using
. Their values will NOT be reset if the protocol is
reset, only if the module is power cycled or the application firmware is reloaded by a
Note
Calling Set Current Tag Protocol will reset the Tag Buffer.
Set Write TX Power (94h)
The Set Write TX Power command sets the default, module-wide, power level to use for writing to tags. This is necessary because a write operation may require a different RF power setting than a read command. The format and arguments of this command are identical to the Set Read TX Power command:
FF
SOH
02
Length
94
OpCode
09 C4
Power in centi-dBm
28
CRC
5B
Note
Power settings for individual logical antenna ports specified in
Command Set
157
Set Application Commands
Set Frequency Hop Table (95h)
The Set Frequency Hop Table command sets the list of frequencies and, optionally, the
Regulatory hop time, to use when hopping. Each frequency is encoded as a 32-bit value in kHz. For instance, 915MHz is encoded as 915000kHz, which is 0x000DF638. The maximum number of hop frequencies is 62, since that is the maximum number of 32-bit values that can be sent using a message packet. If fewer values are used, only those values are populated in the table and the rest of the slots are ignored.
Note
The data length of this message encodes the number of frequencies to populate into the hop table. The length must be divisible by four for the message to be properly formatted.
Setting Frequencies
This example shows a command that sets up a table with only three values:
FF
SOH
0C
Length
95
OpCode
00 0D C3
Freq #1
70 00 0D F6
Freq #2
38 00 0E 26
Freq #3
12 C1
CRC
8F
The generated hop table has values of 902MHz, 915MHz, and 927.25MHz. For the US region, valid frequencies are 902MHz – 928MHz. If any of the values in the table are invalid, then none of the values are recorded.
The Set Frequency Hop Table command should be used for debug only, as there should be no reason to modify the frequency hop table in the field.
158
!
C A U T I O N !
!
Any changes to the frequency hop table could put you out of compliance with the
Local Regulatory Requirements (for example, FCC, ETSI, MIC).
Setting Regulatory Hop Time
Adding option field and specifying option=0x01 allows the hop frequency to be customized up to the maximum time allowed by the regulator limits for the region in use.
Command Set
Set Application Commands
Set Regulatory Hop Time Command Fields (Option = 0x01)
Field Value
Length
OpCode
Option
Regulatory Hop
Time
0x05
0x95
0x01
[4 bytes]
Description
Number of bytes after OpCode
Set Frequency Hop Table
Indicates the Regulatory Hop Time will be passed.
The time between frequency hops, in milli-seconds, to be used for the defined hop table.
Note:
The max hop time is restricted by regulatory limits based
Note
Option=0x00 is reserved and not the same as when no option is specified.
Set User GPIO Outputs (96h)
There are two GPIO outputs available for use. The Set User GPIO Outputs command has been “overloaded” to create a mechanism to return the current state of both GPIO pins. To set either GPIO Output pin, send the following command. Note that the data length is 2 bytes:
FF
SOH
02
Length
96
OpCode
01
GPIO #
01
Output Value
28
CRC
E0
Command Set
159
Set Application Commands
160
This example sets the GPIO Output #1 to ‘1’ (high). To get the current status of the GPIO output pins, send the same command, with the length set to 0:
FF
SOH
00
Length
96
OpCode
1D
CRC
99
The response looks similar to the Get User GPIO Inputs command:
FF
SOH
02
Length
96
OpCode
00
Status
00 00
Output #1
01
Output #2
29
CRC
E0
Set Current Region (97h)
The Set Current Region command sets the current region for use in the reader. The list of region codes are found in
for more information on regional functionality.
Setting the region performs the following:
1.
Frequency hop table is set to the default for the region.
2.
Any other region specific settings are set (i.e. LBT) to default values unless otherwise specified. Currently only LBT is configurable for regions supporting it.
The Set Current Region command supports two command syntaxes:
The basic syntax for all regions where only the region code is specified. For example, to set the region to KR:
FF
SOH
01
Length
97
OpCode
03
Region
4B
CRC
BE
The extended syntax allowing the region code plus LBT Enabled (if supported by
Region) to be set. For example, to set the Region to EU3 and Enable LBT:
FF
SOH
02
Length
97
OpCode
08
Region
01
LBT Enable
19
CRC
FD
Command Set
Set Application Commands
Note
When LBT is disabled in the Open region the M5e/M5e-Compact will implement frequency hopping as implemented for the NA region with a frequency hop interval of 400ms.
Set Power Mode (98h)
The Set Power Mode command can set the M5e to four different power management modes. See
Use the Set Power Mode command to set the power mode to maximum saving mode by sending the following:
FF
SOH
01
Length
98
OpCode
03
Power Mode
44
CRC
BE
Set User Mode (99h)
Use the Set User Mode command to set the user mode to the type of application in which the M5e will be configured for the optimal GEN2 and Search Strategy settings.
Setting the User Mode to an unsupported value will not modify the current setting.
Available Gen2 User Modes
Value User Mode Session Target
0x00
0x01
0x02
0x03
NONE (Default)
PRINTER
Unsupported
PORTAL
0
0
A only
A only
1 A only
Send the following to set the user mode to printer:
FF
SOH
01
Length
99
OpCode
01
User Mode
4
4
M
Q Value (Static/
Dynamic)
InitQ=2 (Dynamic)
InitQ=2 (Dynamic)
4 InitQ=3 (Dynamic)
45
CRC
BC
Command Set
161
Set Application Commands
Note
Setting the parameters using Set User Mode will override the values set by
Set Protocol Configuration (9Bh)
.
Note
For details on the behavior of the Gen2 parameter settings see the
EPCGlobal Gen2 RFID Air Interface Specification v1.2.0
or later.
Set Reader Configuration(9Ah)
The Set Reader Configuration command is used to set several configuration options on the reader. The Option byte indicates whether to use the new key/value pair setting or the previous, bitwise, settings. One example configuration and the corresponding Options value is specified in the command example below. For other combinations the hex value for Options will need to be calculated by OR’ing the bits for each setting.
162
Command Set
Set Application Commands
Option
0x00
Available Configuration Options
Key Value Reader Configuration setting
Indicates the deprecated format of this command will be used:
Command Set
163
Set Application Commands
0x01
164
Use Antenna Port as
Unique Identifier of Tag
Buffer Entry
= 0x00
Transmit Mode
= 0x01
Maximum EPC Length
= 0x02
Use GPIO as Antenna
Switch
= 0x03
Check Antenna
Connection
= 0x04
Record the highest
RSSI seen
= 0x06
Tag Data as Unique
Identifier of
entry. =
0x08
0x00
0x01
Antenna port is a unique characteristic of a Tag Buffer
Entry (
Default
)
Antenna port is ignored for Tag Buffer Entries.
0x01
0x00
0x01
0x00
0x00
0x01
(disables high performance mode)
Maximum EPC length of 96 bits
(Default)
Maximum EPC length of 496 bits
Do NOT use GPO lines for antenna control
(allows for 2 logical antenna ports)
(Default)
Use GPO 1 for antenna control
(allows for 4 logical antenna ports)
0x02
0x03
Note:
See
on setting up logical antenna configurations.
Note:
When changed any previous settings applied with Set Antenna
0x00
0x01
Disable check for a connected antenna before every transmission.
(Default)
Enable check for a connected antenna before every transmission.
Note:
If enabled, it is recommended
Configuration (61h) be used to verify all expected
antennas are detectable. If detection fails for an antenna it will be silently skipped during a search.
0x00
Use GPO 2 for antenna control
(allows for 4 logical antenna ports)
Use Both GPO 1 & 2 for antenna control
(allows for 8 logical antenna ports)
0x01
0x00
0x01
value is the value for the last read tag for each tag buffer entry when this is Dis-
abled. (
Default
)
value will be the highest value recorded during the
search operation.
Tag Data is a unique characteristic of a Tag Buffer Entry.
Tag Data is ignored for Tag Buffer Entry uniqueness
(
Default
)
Command Set
Set Application Commands
Send the following to enable the Low power transmit mode:
FF
SOH
03
Length
9A
OpCode
01
Option
01
Key
01
Value
Note
Multiple settings cannot be applied in a single command.
AE
CRC
5C
Set Protocol Configuration (9Bh)
The Set Protocol Configuration command is used to set protocol-specific configuration parameters. The table below defines the currently available protocol-specific parameters
Command Set
165
Set Application Commands
Protocol
Value
0x05 (Gen2) which can be set and the supported settings. Additional parameters will be supported in the future.
Parameter Option Value
Gen2 Session
used for
Inventory commands.
= 0x00
Gen2 Target used for
Inventory commands.
= 0x01
Gen2 M Value used for
Inventory commands.
= 0x02
Gen2 Q Value
= 0x12
Write Response Wait
Time used to reduce the time a word write operation will wait for a tag response before moving to next word write.
= 0X3F
N/A
0x01 (Static)
0x00 (Toggle A<>B)
Note:
Searches using the toggling behavior will use the value Target was in when the last search ended for the start of the next search. To reset the target this command must be reissued.
N/A
0x00 = Dynamic - Automatically adjust Q value.
0x01 = Static - User specified
Q Value between 0 and 15.
0x00 = Early Exit - If the tag’s response to a word write is detected it moves onto the next word write, otherwise waits for timeout Value.
0x01 = Fixed Wait Time -
Always waits the specified timeout Value per word write.
0x00 - Session = S0 -
(Default)
0x01 - Session = S1
0x02 - Session = S2
0x03 - Session = S3
0x00 - Search Target = A
(
Default
)
0x01 - Search Target = B
0x00 - Search Target starts at A and toggles to B during
Read Tag Multiple (22h) after no more tag are found
with A.
0x01 - Search Target starts at B and toggles to A during
Read Tag Multiple (22h) after no more tag are found
with B.
0x01 (M = 2)
0x02 (M = 4)
(
Default
)
0x03 (M = 8)
N/A
[1 byte] (0x00-0x0F)
[2 bytes] - Wait timeout in microseconds:
• Minimum = 1000us (0x03E8)
• Maximum = 21000us (0x5208)
Note:
Default per Gen2 spec is
Early Exit with a 20000us timeout.
166
Command Set
Set Application Commands
Note
Setting the parameters using Set Protocol Configuration will override the implicit value set by a previous call to Set User Mode. Likewise, a subsequent call to Set User Mode will override the parameters set by Set
Protocol Configuration. Get Protocol Configuration will always return the current setting regardless of whether it was set by Set Protocol
Configuration or Set User Mode.
Note
Changing these protocol parameters manually using
will maintain their value across changes in the current protocol using
Set Current Tag Protocol (93h)
. Their values will NOT be reset if the protocol is
reset, only if the module is power cycled or the application firmware is reloaded by a
Examples
Session
The following example sets the Gen2 session to S2:
FF
SOH
03
Length
9B
OpCode
05
Protocol
00
Parameter
02
Value
DC
CRC
EA
Q Value
The Q valued can be set to a static user specified value or to dynamically change based on ThingMagic internal algorithms. When using the dynamic Q setting the Value parameter is dropped in the command.
The following example statically sets the Q value to 6:
FF
SOH
04
Length
9B
OpCode
05
Protocol
12
Parameter
01
Option
06
Value
The following example sets dynamic Q value adjusting:
FF
SOH
03
Length
80
CRC
A9
9B
OpCode
05
Protocol
12
Parameter
00
Option
CE
CRC
E8
Command Set
167
Set Application Commands
Note
For details on the behavior of the Gen2 parameter settings see the
EPCGlobal Gen2 RFID Air Interface Specification v1.2.0
or later.
168
Command Set
Get Application Commands
Get Application Commands
The Get commands listed in the following table are used to get settable parameters from the Mercury Embedded module. All of the commands have a data length of zero, and return data or a fault code.
Applications Commands – Get
OpCode
0x10
0x61
0x62
0x63
0x64
0x65
0x66
0x67
0x68
0x69
0x6A
0x6B
0x6C
0x70
0x71
0x72
Command Name
Get Antenna Configuration (61h)
Get Current Tag Protocol (63h)
Get Protocol Configuration (6Bh)
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Y
N
Bootloader App Firmware
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_AHAL_TRANSMITTER_ON – 502h
Command Set
169
170
Get Application Commands
Get Hardware Version (10h)
The Get Hardware Version command is used to get information about the module it is executed on. Most of the information is not currently user-relevant but will often be required by ThingMagic Support to help diagnose problems.
Get Hardware Version Fields
Field
Option
1
Data Flags
Value
0x00
0x00
0x40
The format of this command is:
Description
Currently the only supported value.
When no flags are set all data will be returned.
Returns the Reader Serial Number, as printed on the barcode label, as ASCII values.
FF
SOH
02
Length
10
OpCode
00
Option
00
Data
Flags
F0
CRC
93
Note
On many earlier hardware revisions a status code of 0x0109
(FAULT_UNIMPLEMENTED_FEATURE) will be returned. This indicates the necessary information for this command was not stored on the module at that time. It is not cause for concern.
Get Antenna Configuration (61h)
The Get Antenna Configuration command returns the current antenna configuration including which antennas are set to transmit and receive, and which ports have antennas attached.
Reliable antenna detection requires that an attached antenna pass at least a small amount of DC current. Many antennas do not pass DC current. Due to such antennas an indication that a port is terminated is always accurate, but an indication that a port is not terminated may not be accurate.
Command Set
Get Application Commands
Non-Multiplexer Options
For backward compatibility the following syntax(Option=0x00 and 0x01) is supported when using only the physical module ports directly. For new development the
The format of the command is:
FF
SOH
01
Length
61
OpCode
00
Option
BD
CRC
BD
The reply is formatted similar to the Set Antenna Port command. Data byte 01 returns the current TX antenna, and data byte 02 returns the current RX antenna. The default antenna configuration is TX on port #1, and RX on port #2, except on the M5e-Compact which only has 1 port so the M5e-Compact’s default is TX on port #1 and RX on port #1.
FF
SOH
02
Length
61
OpCode
00
Status
00 01
TX Ant Num
02
RX Ant Num
4E
CRC
21
The Get Antenna Configuration command also includes an option that also returns information on which port(s) the antenna is connected.
For example, a command is sent:
FF
SOH
01
Length
61
OpCode
01
Option
BD
CRC
BC
The response returns the ports for TX and RX and also detects whether an antenna is connected to the port:
FF
SOH
04
Length
61
OpCode
00
Status
00 01
TX Ant Num
01
RX Ant Num
00
Port 1
Not Connected
01
Port2
Connected
A7
CRC
02
Command Set
171
Get Application Commands
Logical Antenna Options
The new Get Antenna Configuration options allow you to get the logical antenna configuration of the module. This syntax supports detecting antennas connected to a multiplexer provided the appropriate GPIO control lines have been enabled using
.
Get Antenna Port Command Fields
Field
Length
OpCode
Option
Value Description
0x01
0x61
0x02
0x03
0x04
0x05
Number of bytes after OpCode
Get Antenna Port
Return the Antenna Search Order as specified by Set Multi-Antenna
Returns all TX Antennas and their associated Power settings as specified
by Set Antenna’s Power and Settling Time
Returns all TX Antennas and their associated Power and Settling time settings as specified by
Set Antenna’s Power and Settling Time
Returns all “valid” Logical Antenna Ports and their connection status.
Note:
“Valid” ports are defined by the tables for the specific control lines in use.
For options 0x02, 0x03 and 0x04 the returns values, fields and order are equivalent to the
settings using the same option with
Get Antenna Port Status Response Fields (Option = 0x05)
Field
Length
OpCode
Status
Option
Logical Antenna
Value
[1 byte]
0x91
[2 bytes]
0x05
[1 byte]
Connection Status 0x00
0x01
Description
Number of bytes after OpCode
Set Antenna Port
Status of command
Indicates the data to follow contains each logical antenna available and its connection status (is an antenna detected).
Specifies the logical antenna the following connection status applies to.
No antenna detected
Antenna (or termination) detected.
172
Command Set
Get Application Commands
Field Value Description
Repeat for all available logical antennas, as defined by the settings in
Get Read TX Power (62h)
For deprecated version of this command see Appendix D:
The Get Read TX Power command returns the current TX power and, optionally, the minimum and maximum power levels supported by the module (and region setting) for reading tags, in centi-dBm.
The option field allows you to specify what data you want returned:
Option
0x00
0x01
Data returned
Returns only the current TX power.
Returns the current TX power and the maximum and minimum power levels for this module.
The following example gets the full set of power data:
FF
SOH
01
Length
62
OpCode
01
Option
BE
CRC
BC
The example response contains the option specified followed by 2 byte fields for each power value: current = 0x0BB8 = 3000 centi-dBm = 30.00 dBm max = 0x0BB8 = 3000 centi-dBm = 30. 00 dBm min. = 0x01F4 = 500 centi-dBm = 5.00 dBm
FF
SOH
07
Length
62
OpCode
00
Status
00 01
Option
0B B8
Current centi-dBm
0B B8
Max centi-dBm
01 F4
Min centi-dBm
1F
CRC
B7
Command Set
173
174
Get Application Commands
Get Current Tag Protocol (63h)
The Get Current Tag Protocol command returns the currently set tag protocol(s). This is the protocol being used by the reader. The following table assigns a 16-bit code to each available protocol. This table will be updated as new protocols are added:
Protocol Name
None Selected
EPC0 / EPC0+ Matrics
EPC1
ISO 18000-6B
EPC0+ Impinj
GEN2
UCODE
16-bit Code
0x0000
0x0001
0x0002
0x0003
0x0004
0x0005
0x0006
The command format is shown in the following example:
FF
SOH
00
Length
63
OpCode
1D
CRC
6C
Note
The M5e and M5e-Compact only support GEN2
The reply is similar to the Set Current Tag Protocol command. Only one protocol can be set at a time:
FF
SOH
02
Length
63
OpCode
00
Status
00 00 01
Current Protocol
21
CRC
42
Command Set
Command Set
Get Application Commands
Get Write TX Power (64h)
For deprecated version of this command see Appendix D:
The Get Write TX Power command returns the current TX power and, optionally, the minimum and maximum power levels supported by the module for reading tags, in centidBm.
The option field allows you to specify what data you want returned:
Option
0x00
0x01
Data returned
Returns only the current TX power.
Returns the current TX power and the maximum and minimum power levels for this module.
The following example gets the full set of power data:
FF
SOH
01
Length
64
OpCode
01
Option
B8
CRC
BC
The example response contains the option specified followed by 2 byte fields for each power value: current = 0x0BB8 = 3000 centi-dBm = 30.00 dBm max = 0x0BB8 = 3000 centi-dBm = 30.00 dBm min. = 0x01F4 = 500centi-dBm = 5.00 dBm
FF
SOH
07
Length
64
OpCode
00
Status
00 01
Option
0B B8
Default centi-dBm
0B B8
Max centi-dBm
01 F4
Min centi-dBm
FF
CRC
BC
Get Frequency Hop Table (65h)
The Get Frequency Hop Table command gets the current frequency hop table and, optionally, the frequency hop time, used.
Get Frequencies
The following command gets the list of frequencies current used in the hop table.
175
Get Application Commands
FF
SOH
00
Length
65
OpCode
1D
CRC
6A
The reply format is similar to the Set Frequency Hop Table command. The length must be set to a multiple of four, and a maximum of 62 hop frequencies is returned. The frequencies are returned in kHz. Thus, frequency #1 (0xDC370) corresponds to 902,000 kHz:
FF
SOH
0C
Length
65
OpCode
00 00
Status
00 0D C3 70
Freq #1
00 0D F6 38 00 0E 26 12 60 B2
Freq #2 Freq #3 CRC
Get Regulatory Hop Time
Adding the option field and specifying option=0x01 returns the hop frequency in use.
Get Regulatory Hop Time Command Fields (Option = 0x01)
Field
Length
OpCode
Option
0x01
0x65
0x01
Value Description
Number of bytes after OpCode
Get Frequency Hop Table
Indicates the Regulatory Hop Time will be passed.
Get Regulatory Hop Time Response Fields (Option = 0x01)
Field Value
Length
OpCode
Status
Option
Regulatory Hop
Time
0x05
0x65
[2 bytes]
0x01
[4 bytes]
Description
Number of bytes after OpCode
Get Frequency Hop Table
Status
Indicates the Regulatory Hop Time will be passed.
The hopping interval, in milli-seconds, currently used for the defined hop table.
176
Command Set
Get Application Commands
Note
Option=0x00 is reserved and not the same as when no option is specified.
Command Set
177
178
Get Application Commands
Get User GPIO Inputs (66h)
The Get User GPIO Inputs command returns the status of the User Input GPIO lines:
FF
SOH
00
Length
66
OpCode
1D
CRC
69
The status of the GPIO lines is returned.
FF
SOH
02
Length
66
OpCode
00
Status
00 00
Input #1
01
Input #2
CA
CRC
B2
Note
The GPI lines are level sensed and not edge sensed. When Get User GPIO
Inputs is called it will respond with the signal level (high or low) on the line at that moment.
Get Current Region (67h)
The Get Current Region command gets the current regulatory region set for the reader.
Currently available region codes are shown in the following table. Details on the
Regulatory Compliance for each region can be found in
:
Command Set
Get Application Commands
Region codes
Region Code
PRC
EU2
EU3
KR2
NA
EU
KR
IN
AU
NZ
Open
0x01
0x02
0x03
0x04
0x06
0X07
0x08
0x09
0x0B
0x0C
0xFF
To get the current region send the following command:
FF
SOH
00
Length
67
OpCode
1D
CRC
68
The command generates the following reply, which indicates that the reader is set to the
NA region:
FF
SOH
01
Length
67
OpCode
00
Status
00 01
Region
B4
CRC
80
Get Power Mode (68h)
The Get Power Mode command returns the current Power Mode of the unit. The values for the available
Command Set
179
Get Application Commands
Available power modes
Hex
0x00
0x01
0x02
0x03
0x04-0xFF
Power Mode
Full power mode
Minimal saving mode.
Medium saving mode.
Maximum saving mode.
Reserved for future use.
Note
Maximum Saving Mode only supports communications at 9600 baud
The command gets the current power mode setting from the module:
FF
SOH
00
Length
68
OpCode
1D
CRC
67
The example reply shows that the system is in the medium power saving mode:
FF
SOH
01
Length
68
OpCode
00
Status
00 02
Power Mode
A4
CRC
BD
180
Get User Mode (69h)
The Get User Mode command returns the type of application in which the M5e/M5e-
Compact can be used. The list of user modes and their corresponding protocol configuration settings can be found in
.
The command gets the current user mode setting from the module:
FF
SOH
00
Length
69
OpCode
1D
CRC
66
The example reply shows the current user mode setting:
Command Set
Get Application Commands
FF
SOH
01
Length
69
OpCode
00
Status
00 01
User Mode
97
CRC
8F
Get Reader Configuration(6Ah)
For the previous version of this command see Appendix D:
The Get Reader Configuration command returns the current reader configuration for the setting specified by the key field as defined in
using Option=0x01. When using Option=0x00 it will use the previous format of the command.
Send the following command to get the current Unique Read setting:
FF
SOH
02
Length
6A
OpCode
01
Option
00
Key
The example reply shows the current configuration setting:
2E
CRC
4E
FF
SOH
03
Length
6A
OpCode
00
Status
00 01
Option
00
Key
01
Value
AF
CRC
5C
Get Protocol Configuration (6Bh)
The Get Protocol Configuration command is used to get current protocol-specific
configuration parameters settings as specified in
Set Protocol Configuration (9Bh)
.
Send the following command to get the current Gen2 Session configuration parameter value:
FF
SOH
02
Length
6B
OpCode
05
Protocol
00
Parameter
The example reply shows the Gen2 session is set to S2 (0x02):
3A
CRC
6F
Command Set
181
182
Get Application Commands
FF
SOH
03
Length
6B
OpCode a
00
Status
00 05
Protocol
00
Parameter
02
Value
08
CRC
76
Get Reader Statistics (6Ch)
The Get Reader Statistics command allows the user to get and reset various statistics on the reader operation. The command takes the following fields:
Get Reader Statistics Request Fields
Field Value
Option (1 byte)
Statistics Flag (1 byte)
Requested Ports Length (1 byte)
• 0x00 - Get statistics specified by the Statistics Flag
• 0x01 - Reset the specified statistic.
• 0x02 - Get requested statistics for each port and include port
ID in response.
• 0x03 - Get requested statistics for Request Ports.
Each bit corresponds to a specific statistic to be returned. See the
table for bit values.
Note:
Only include if Option = 0x03
Number of ports statistics are requested for. Indicates the number
(N) bytes to follow.
Requested Ports (N bytes) Note:
Only include if Option = 0x03
Port ID of ports to return statistics for.
Note:
When getting statistics for all ports the returned ports is impacted by the Available Configuration
Options
| Check Antenna Connection.
• If checking is enabled then only values for connected/detectable antenna ports are returned.
• If checking is disabled then values for all antenna ports are returned. However, if a port is not
connected it is possible this command will fail with a FAULT_HIGH_RETURN_LOSS – 505h
status.
Command Set
Get Application Commands
Available Statistics
Statistics Flag Bit Statistic
Bit 0 (0x01)
Bit 1 (0x02)
Bit 3 (0x08)
RF On Time (ms)
- Indicates the aggregate time the transmitter has been on, in milliseconds, since the counter was last reset.
Returned value contains N bytes (N/2 on the M5e-Compact), Where N = the number
of valid logical antennas based on the Antenna Ports configuration X 4 bytes for
each antenna.
Note:
Clock rolls over every 2 user application.
32
milliseconds and must be taken into account by
Noise Floor - When requested the reader will listen on each available logical antenna and report the noise floor in units equivalent to the units returned for
RSSI value.
Returned value contains N bytes (N/2 on the M5e-Compact), Where N = the number
of valid logical antennas based on the Antenna Ports
configuration x 1 byte for each antenna, in ascending antenna order.
Note:
A single RF operation (read, etc.) must be performed before this operation can return valid data.
Noise Floor with TX On - When requested the reader will transmit a CW signal on each available logical antenna and report the noise floor detected in units equivalent
to the units returned for Tag Read Meta Data
RSSI value.
Returned value contains N bytes (N/2 on the M5e-Compact), Where N = the number
of valid logical antennas based on the Antenna Ports
configuration x 1 byte for each antenna, in ascending antenna order.
Note:
Multiple statistics can be requested by a single command by performing a binary OR (setting each desired Statistics Flag bit to 1) on the desired flags and sending the result as the Statistics Flag byte.
The response to a Get Reader Statistics command contains the following information:
Command Set
183
Get Application Commands
Get Statistics Response Fields
Field Description
Status (2 bytes)
Option (1 byte)
Data Length (1 byte)
Antenna Port ID
Standard response status
Same as the Requested Value
Requested Statistics Flag (1 byte) Same as the Requested Value
For each individual statistics requested as part of the Requested Statistics Flag the following fields will be repeated according to the Statistics Response value. They will be in bit value order.
Statistic Flag (1 byte) The bit corresponding to the requested statistic.
Indicates how many bytes are in this statistics response value.
Note:
Only included when Option=0x02
Antenna port ID
1
of the following Statistic value.
Statistics Response Value (N bytes as indicated by Data Length)
The response value of the statistic as specified in Available Statistics
Note:
all antenna values correspond to the Logical Antenna Setting antenna value.
To request the Noise floor with TX on, including portID for all ports, send the following command:
FF
SOH
02
Length
6C
OpCode
02
Option
08
Statistics Flag
XX
CRC
XX
The response (from an M5e with two antennas), containing the RF On Time for each antenna would look like:
FF
SOH
08
Length
6C
OpCod e
00 00
Status
02
Option
08 08
Requested
Stats Flag
Stat Flag
(Noise)
04
Data
Length
01
Antenna
ID
44
Noise floor
02
Antenna
ID
25
Noise floor
XX
CRC
XX
To reset the RF On Time statistic send the following command:
FF
SOH
02
Length
6C
OpCode
01
Option
01
Statistics Flag
4E
CRC
89
184
Command Set
Get Application Commands
Get Available Protocols (70h)
The Get Available Protocols command returns the list of protocols that the reader is capable of reading. The protocol codes are defined in
Get Current Tag Protocol (63h)
. The total number of protocols in the system cannot exceed 32. The command is generated as follows:
FF
SOH
00
Length
70
OpCode
1D
CRC
7F
The following Microprocessor response shows that the reader is capable of reading one protocol – GEN2:
FF
SOH
02
Length
70
OpCode
00
Status
00 00
Protocol #1
05 3B
CRC
75
Get Available Regions (71h)
The Get Available Regions command returns the list of regions that the reader is capable of working in. The total number of regions in the system cannot exceed 248. The list of region codes are found in
. The command is generated as follows:
FF
SOH
00
Length
71
OpCode
1D
CRC
7E
The response shows that this reader is capable of reading in four regions – NA, EU, KR, and EU2:
FF
SOH
03
Length
71
OpCode
00
Status
00 01
Region#1
02
Region#2
03
Region#3
07
Region#7
39
CRC
FF
Command Set
185
186
Get Application Commands
Get Current Temperature (72h)
The Get Current Temperature command returns the current board component temperature on the module in degrees Celsius as a signed 8-bit integer. This information can be used to determine if the module is exceeding its recommended operating temperature range. If the returned value exceeds the values specified in the table below an effort should be made to reduce the ambient temperature of the module or reduce the module’s duty cycle.
Module Warning Temperature
M5e
M5e-C
85
°C
80
°C
Note
In M5e Firmware release v1.5.1 the temperature threshold value changed.
This change is due to a value calculation change and not a change in the actual temperature threshold. The previous values returned were in uncalibrated “units”, not actual degress Celcius.
The command is generated as follows:
FF
SOH
00
Length
72
OpCode
1D
CRC
7D
The response returns a signed 8-bit integer in degrees Celsius, 0x24 = 36 o
C
FF
SOH
01
Length
72
OpCode
00
Status
00 24
Temperature in Celsius
48
CRC
23
Command Set
FCC Test Commands
FCC Test Commands
The following OpCodes are used for test purposes including regulatory certification testing.
Note
Set Power Mode to Full 0x00 before running FCC commands.
FCC Test Commands
OpCod e
0xC1
0xC3
Command Name Arguments Return BL
Frequency in kHz none
CW mode, [timeout] none
N
N
Y
Ap p
Y
Y
M5e/M5e-
Compact
Y
Command Set
187
188
FCC Test Commands
Set Operating Frequency (C1h)
The Set Operating Frequency command takes a 32-bit frequency value, expressed in kHz. For instance, to set the frequency to 915.26MHz, send the data value 915260
(0x000D F73C) to the reader.
FF
SOH
04
Length
C1
OpCode
00 0D F7
Freq to Set
3C F3
CRC
B7
Transmit CW Signal (C3h)
The Transmit CW Signal command turns the Continuous Wave (CW) signal On or Off or enables a PRBS signal. Sending 0x00 turns Off the CW signal; sending 0x01 turns On the CW signal; Sending 0x02 turns on a PRBS signal. The CW signal is transmitted at the last used power level.
This example shuts off CW:
FF
SOH
01
Length
C3
OpCode
00
CW
1F
CRC
BD
Some regulatory testing requires a PRBS (Pseudo-Random Bit Sequence) signal to simulate data transmission. To send a PRBS signal, along with sending CW=0x02, the
Length field must be changed to 0x03. This indicates PRBS will be used and an extra 2 byte Timeout field must be added. When this PRBS mode is used the CW signal is on until the timeout expires, during that period the reader does not respond to commands.
The following example generates a PRBS CW signal for 256 ms, 100% duty cycle:
FF
SOH
03
Length
C3
OpCode
02
CW/PRBS
01 00
Timeout
01
CRC
00
Command Set
Appendix A: Hardware Details
This Appendix details the mechanicals for the embedded modules and also provides pin
1 locations for the M5e and M5e-Compact serial connectors.
Mechanicals
The following figures detail the hardware layouts that comprise the Mercury Embedded
Modules.
Appendix A: Hardware Details
189
M5e Mechanicals
Mechanicals
190
Appendix A: Hardware Details
M5e-Compact Mechanical
Mechanicals
Antenna Connector
The M5e has two MMCX connectors and the M5e-Compact has one MMCX connector for interfacing to the antennas.
Appendix A: Hardware Details
191
192
Mechanicals
Communications Connector
The communications interface on the modules provides power, serial communications signals, and access to the GPIO inputs and outputs.
The M5e and M5e-Compact have a 12-pin connector. For the interface pin-out, see
M5e-Compact Digital Connectors
.
The following figure shows the diagrams of the M5e, and M5e-Compact communications interface as you face the boards.
M
5e
M
5e
Compact
Pin 1 Pin 12
Pin 1
Pin 12
Ribbon cable
Note
The flat ribbon cable that connects with the communications interface on the
M5e and M5e-Compact embedded modules is available from Parlex,
Part Number: 100R12-152B; and can be purchased from standard electronic component suppliers.
Appendix A: Hardware Details
Appendix B: Getting Started - Devkit
Devkit Hardware
Included Components
With the devkit, you will receive the following components:
The M5e/C module and power/interface developers board
One USB cable (may contain two host-side connectors, do not use the
Red
one)
One antenna
One coax cable
One 9V power supply
International power adapter kit
Sample tags
Two paper inserts:
–
QuickStart Guide
- Details on which documents and software to download to get up and running quickly, and how to register for and contact support..
Setting up the DevKit
When setting up the DevKit, use the following procedures:
Powering up and Connecting to a PC
Appendix B: Getting Started - Devkit
193
Devkit Hardware
Connecting the Antenna
ThingMagic supplies one antenna that can read tags from 20’ away with most of the provided tags. The antenna is monstatic. Use the following procedure to connect the antenna to the DevKit.
1.
Connect one end of the coax cable to the antenna.
2.
Connect the other end of the cable to Ant 1 connector on the DevKit.
Powering up and Connecting to a PC
After connecting the antenna you can power up the DevKit and establish a host connection.
1.
Connect the USB cable (use only the black connector) from a PC to the developer’s
2.
Plug the power supply into the DevKit’s DC power input connector.
3.
The LED next to the DC input jack, labeled DS1, should light up. If it doesn’t light up check jumper
to make sure the jumper is connecting pins 2 and 3
4.
Follow the steps in
and make note of the COM port or /dev
device file, as appropriate for your operating system the USB interface is assigned.
5.
To start reading tags start the
W A R N I N G !
While the module is powered up, do not touch components. Doing so may be damaged the devkit and M5e module.
Devkit USB Interface
USB/RS232
The USB interface (connector labeled USB/RS232) closest to the power plug is to the
RS232 interface of the M5e through an FTDI USB to serial converter. The drivers for it are available at http://www.ftdichip.com/Drivers/VCP.htm
Please follow the instructions in the installation guide appropriate for your operating system.
194
Appendix B: Getting Started - Devkit
Devkit Hardware
Native USB
Not applicable to the M5e.
Devkit Jumpers
J8
Jumpers to connect M5e I/O lines to devkit.
J9
Header for alternate power supply. Make sure DC plug (J1) is not connected if using J9.
J10, J11, J13, J15
Do not change.
Jump pins OUT to GPIO# to connect M5e GPIO lines to output LEDs. Jump pins IN to
GPIO#
to connect M5e GPIO to corresponding input switches SW[3-6]GPIO#. The M5e
GPIO lines are not configurable as Inputs or Outputs so the jumpers should not be changed from their factory settings, as follows:
M5e GPO1 is devkit GPIO1 - J10 jumper pins 1 to 2
– DS2 lights when GPO1 is low
M5e GPO2 is devkit GPIO2 - J11 jumper pins 1 to 2
– DS3 lights when GPO2 is low
M5e GPI1 is devkit GPIO3 - J13 jumper pins 2 to 3
– SW6 controls logic level to GPI1
M5e GPI2 is devkit GPIO4 - J15 jumper pins 2 to 3
– SW7 controls logic level to GPI2
J14
Can be used to connect GPIO lines to external circuits. If used jumpers should be
.
J16
Jump pins 1 and 2 or 2 and 3 to reset devkit power supply. Same as using switch SW1 except allows for control by external circuit.
Appendix B: Getting Started - Devkit
195
Devkit Hardware
J17
Jump pins 1 and 2 to use the 5V INPUT and GND inputs to provide power. Jump pins 2 and 3 to use the DevKit’s DC power jack and power brick power.
J19
Do not change
Devkit Schematics
Available upon request from [email protected].
196
Appendix B: Getting Started - Devkit
Demo Application
Demo Application
A demo application which supports multi-protocol reading and writing is provided in the
MercuryAPI SDK package. The executable for this example is included in the MercuryAPI
SDK package under /cs/samples/exe/Universal-Reader-Assistant.exe and the source code under /cs/samples/Universal-Reader-Assistant/Universal-Reader-Assistant.exe.
See the Readme.txt in /cs/samples/Universal-Reader-Assistant/Universal-Reader-
Assistant for usage details.
See the
MercuryAPI Programming Guide
for details on using the MercuryAPI.
Appendix B: Getting Started - Devkit
197
198
Demo Application
Arbser Command Line Utility
The ArbSer program is a simple terminal program with which you can communicate with the M5e, and M5e-C modules. It provides several pre-formed commands, as well as a raw message interface that can be used to generate any command. The source code is part of the developer’s kit to provide an example of the message format and CRC calculation.
The executable was built using a Windows 2000 PC. If the host PC’s operating system is different, the executable should be rebuilt using Microsoft Visual C++ 6.0, or other compatible compiler. If building ArbSer on another platform, some work may be necessary to integrate the serial port properly.
ArbSer provides a help message if it is called with no argument:
C:\> ArbSer
ArbSer Version 3.1.1 compiled on Nov 8 2004 at 11:44:05.
Usage: ArbSer <baud> <COM port> <option>
Default baud rate is 9600. To use 115200: ArbSer 115200 <options>
Default COM port is COM1. To use COM3: ArbSer <baud> -
c3
<options>
Only one option can be used at a time:
-eraseApp
– Erase application FW only (sectors 1-8).
-genMsg
– Generates a msg and prints it to console.
-go
– Start the application FW.
-l5a MercuryE
– Load the M5e or M5e-C application FW(*.sim file) into FLASH
Appendix B: Getting Started - Devkit
Demo Application
-msg xx xx xx
... – Send properly formatted msg (appends SOH and CRC).
-raw xx xx xx
... – Send raw hexadecimal msg (illegal msgs possible).
-ver
– Returns the version information.
When using ArbSer, the serial port and baud rate can be changed from the default of
COM1 and 9600 bps. Then, one of the options must be selected. The most useful ones are ‘
-go
’, ‘
-msg
’, and ‘
-ver
’. These commands provide the ability to exercise every feature of the modules.
Reading a Tag
Now that the module is connected to the PC and is powered on, the ArbSer.exe program is used to communicate with it. Send the sequence of commands described in this section.
The raw hexadecimal output sent through the serial port is shown following the ArbSer command. This is an example of the exact serial traffic sent to the Microprocessor.
Appendix B: Getting Started - Devkit
199
Demo Application
200
Get Version Command
When the unit is first powered up, the boot loader is running. Verify that the module is alive by sending a Get Version command:
C:\> ArbSer
–ver
< Equivalent to: FF 00 03 1D 0c >
Valid message received:
Data Length = 14
OpCode = 03
Status = 00 00
Data[000] = 03
Data[001] = 01
Data[002] = 00
Data[003] = 05
Data[004] = FF
Data[005] = FF
Data[006] = FF
Data[007] = FF
Data[008] = 20
Data[009] = 04
Data[010] = 11
Data[011] = 03
Data[012] = 03
Data[013] = 01
Data[014] = 00
Data[015] = 06
Data[016] = 00
Appendix B: Getting Started - Devkit
Demo Application
Data[017] = 00
Data[018] = 00
Data[019] = 07
CRC = 42EA
The module returns its version information. In the previous example, the version number shows the following:
Boot loader version #3.1.5
Application FW build date: 11/03/2004
Application FW version #3.1.6
3 protocols enabled (EPC0, EPC1, ISO18000-6B).
Boot Firmware Command
Next, send a Boot Firmware command:
C:\> ArbSer
–go
< Equivalent to: FF 00 04 1D 0B >
Appendix B: Getting Started - Devkit
201
Demo Application
202
Valid message received:
Data Length = 14
OpCode = 04
Status = 00 00
Data[000] = 03
Data[001] = 01
Data[002] = 00
Data[003] = 05
Data[004] = FF
Data[005] = FF
Data[006] = FF
Data[007] = FF
Data[008] = 20
Data[009] = 04
Data[010] = 11
Data[011] = 03
Data[012] = 03
Data[013] = 01
Data[014] = 00
Data[015] = 06
Data[016] = 00
Data[017] = 00
Data[018] = 00
Data[019] = 07
CRC = 4B6A
Appendix B: Getting Started - Devkit
Demo Application
This returns the same version information as the -ver command previously documented.
Now that the application FW has been started, the reader is ready to accept protocol commands. To read an EPC0 tag, place the tag about one foot away from the antenna.
Then send the following series of commands.
Set Current Region Command
Before you can start reading tags with the M5e and M5e-C, you must set the region in which the reader resides.
For example, if the region is the European Union, using the Set Current Region command, set the region as follows:
C:\> ArbSer –msg 01 97 02
<Equivalent to: FF 01 97 02 4B BE>
Valid message received:
Data Length = 00
OpCode = 93
Status = 00 00
CRC = 371A
Appendix B: Getting Started - Devkit
203
Demo Application
204
Set Current Tag Protocol Command
When the application FW first starts, there is no default protocol loaded. Thus, the protocol to use must be specified.
For this example, the protocol is set to EPC0 using the Set Current Tag Protocol command:
C:\> ArbSer
–msg
02 93 00 01
< Equivalent to: FF 02 93 00 01 51 79 >
Valid message received:
Data Length = 00
OpCode = 93
Status = 00 00
CRC = 371A
Set Read TX Power Command
The default read power setting for the modules is 26.5 dBm. This should be adequate to read the tag from 1 foot. If a different power setting is desired, it should be entered now.
The following Set Read TX Power command sets the power level to 25.0 dBm (0x09C4):
C:\> ArbSer
–msg
02 92 09 C4
< Equivalent to: FF 02 92 09 C4 FC E5 >
Valid message received:
Data Length = 00
OpCode = 92
Status = 00 00
CRC = 273B
Set Antenna Port Command
The default antenna port configuration is a 2-port antenna, with TX on port 1 and RX on port 2. If a different configuration is being used, it should be changed before attempting to
Appendix B: Getting Started - Devkit
Demo Application read tags. For example, to use a one-port configuration that uses only port 1, use the Set
Antenna Port
command:
C:\> ArbSer
–msg
02 91 01 01
< Equivalent to: FF 02 91 01 01 70 3B >
Valid message received:
Data Length = 00
OpCode = 91
Status = 00 00
CRC = 1758
Finally, the module is ready to execute a read command. The timeout for the read can be set anywhere from 0 ms to 65,536 ms. Using the Read Single Tag ID command, the timeout is set to 1 s, which is 1000 ms (0x03E8):
Appendix B: Getting Started - Devkit
205
206
Demo Application
C:\> ArbSer
–msg
02 21 03 E8
< Equivalent to: FF 02 21 03 E8 D5 09 >
Valid message received:
Data Length = 0E
OpCode = 21
Status = 00 00
Data[000] = 12
Data[001] = 34
Data[002] = 56
Data[003] = 78
Data[004] = 9A
Data[005] = BC
Data[006] = DE
Data[007] = F0
Data[008] = AA
Data[009] = BB
Data[010] = CC
Data[011] = DD
Data[012] = 23
Data[013] = 79
CRC = 2384
The module should now return the tag ID of the tag. In this example, the 96-bit EPC0 tag
ID is (0x12 34 56 78 9A BC DE F0 AA BB CC DD) with a tag ID CRC of 0x2379.
Appendix B: Getting Started - Devkit
Demo Application
Unexpected Results
Sometimes you do not get the results that you expected. The following sections explain some problems that can occur when the previously listed sequence of commands are used. The following sections explain some of the frequently encountered errors.
Serial Communication Does Not Work
If serial communications fails to work using the ArbSer command, check the following:
The baud rate is correct.
If the baud rate of the boot loader or application FW was changed, then specify the current baud rate using ArbSer. For example, “ArbSer <baudrate> ...”.
The correct COM port is being used.
ArbSer does not return an error if it is able to open the specified COM port. Currently,
ArbSer works on COM1 to COM9.
The commands are properly formed.
If no SOF byte (0xFF) is used, or an incorrect CRC or number of data elements is specified, then the Microprocessor does not respond to the message at all.
The module is properly connected and powered on.
The serial cable should not be a NULL modem cable.
The PC serial port is working properly.
An RS-232 line checker is helpful for this.
A simple way to check that serial communications is working is to try sending a Get
Version
command. If a valid response is received, then the physical communication layer is intact and working properly. That is to say that the baud rate, COM port, and cables are all fine.
Commands Return a Non-Zero Status Code
If a command returns a non-zero status code, this is not always an error. However, if a non-zero code is received in response to a Set command, such as Set Current Tag
Protocol
,
Set Read TX Power
,
or Set Antenna Port commands, it is likely that one of the following problems exists:
The module is still executing the boot loader program.
Appendix B: Getting Started - Devkit
207
208
Demo Application
Send a Boot Firmware command to verify that the application FW is running. If the boot loader is currently running, then a set command will return a 0x0101 status code, indicating an invalid OpCode.
The parameter(s) to the set command are invalid. If an invalid parameter is sent, then a 0x0105 status code is returned, indicating an invalid parameter value.
If the wrong number of data elements is used, then a 0x0100 status code (wrong number of data) is returned. This could be the result of an ill-formed command, or accidentally using the wrong OpCode.
No Tag ID is Returned
If the Read Tag ID Single command returns an error code of 0x0400 (no tag found), then most likely it is a set up related issue. Check the following items:
The antenna is properly connected to the unit and configured using the Set Antenna
Port
command.
The tag is the right protocol (that is EPC0) and that the protocol has been set using the Set Current Tag Protocol command.
Try using a longer timeout, such as 30 seconds, and varying the tag’s location in relation to the antenna.
It is also possible the tag may be erased or damaged. Without a second “known good” reader, it is difficult to tell if this is the case. If a “known good” tag is available, try to read it.
Appendix B: Getting Started - Devkit
Minimum Set of Serial Commands
Minimum Set of Serial Commands
The minimum set of commands required to setup the M5e for reading are:
:
0xFF 0x00 0x04 0x1D 0x0B
Set Current Tag Protocol (93h)
[to Gen2]
0xFF 0x02 0x93 0x00 0x05 0x51 0x7D
0xFF 0x01 0x87 0x08 0x4B 0xB5
Notice you must first boot the application firmware (0x04) so you can successfully execute the setup commands. The "Set" commands cannot be executed when running in the bootloader mode.
Once configure you can perform inventory operations using the Read Tag Multiple (0x22) command. This results in tags being stored in the tag Buffer on the module. You then need to execute Get Tag Buffer (0x29) operations to retrieve the tags. See the docs for more details on how those work. A very simple usages is:
0xFF 0x02 0x22 0x01 0xF4 0xE7 0x76
- Can return max 13 tags so if Read Tag Multiple resulted in more than 13 being stored then multiple Get Tag Buffer commands must be sent.
0xFF 0x03 0x29 0x00 0x00 0x00 0xF4 0x22
Appendix B: Getting Started - Devkit
209
Notice on Restricted Use of the DevKit
Notice on Restricted Use of the DevKit
The Mercury5e Developers Kit (DevKit) is intended for use solely by professional engineers for the purpose of evaluating the feasibility of applications.
The user’s evaluation must be limited to use within a laboratory setting. This DevKit has not been certified for use by the FCC in accordance with Part 15 of the FCC regulations,
ETSI, KCC or any other regulatory bodies and may not be sold or given for public use.
Distribution and sale of the DevKit is intended solely for use in future development of devices which may be subject to regional regulatory authorities governing radio emission.
This DevKit may not be resold by users for any purpose. Accordingly, operation of the
DevKit in the development of future devices is deemed within the discretion of the user and the user shall have all responsibility for any compliance with any regional regulatory authority governing radio emission of such development or use, including without limitation reducing electrical interference to legally acceptable levels. All products developed by user must be approved by the appropriate regional regulatory authority governing radio emission prior to marketing or sale of such products and user bears all responsibility for obtaining the prior appropriate regulatory approval, or approval as needed from any other authority governing radio emission.
210
Appendix B: Getting Started - Devkit
Appendix C: Error Messages
Common Error Messages
The following table lists the common faults discussed in this section.
Fault Message
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_UNIMPLEMENTED_OPCODE – 102h
FAULT_MSG_POWER_TOO_HIGH – 103h
FAULT_MSG_INVALID_FREQ_RECEIVED - 104h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_MSG_POWER_TOO_LOW - 106h
FAULT_UNIMPLEMENTED_FEATURE - 109h
FAULT_INVALID_BAUD_RATE - 10Ah
Code
100h
101h
102h
103h
104h
105h
106h
109h
10Ah
10Bh
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
Cause
If the data length in any of the Host-to-M5e/M5e-Compact messages is less than or more than the number of arguments in the message, the reader returns this message.
Appendix C: Error Messages
211
212
Common Error Messages
Solution
Make sure the number of arguments matches the data length.
FAULT_INVALID_OPCODE – 101h
Cause
The opCode received is invalid or not supported in the currently running program
(bootloader or main application) or is not supported in the current version of code.
Solution
Check the following:
Make sure the command is supported in the currently running program.
Check the documentation for the opCode the host sent and make sure it is correct and supported.
Check the previous module responses for an assert (0x7F0X) which will reset the module into the bootloader.
FAULT_UNIMPLEMENTED_OPCODE – 102h
Cause
Some of the reserved commands might return this error code.
This does not mean that they always will do this since ThingMagic reserves the right to modify those commands at anytime.
Solution
Check the documentation for the opCode the host sent to the reader and make sure it is supported.
Appendix C: Error Messages
Common Error Messages
FAULT_MSG_POWER_TOO_HIGH – 103h
Cause
A message was sent to set the read or write power to a level that is higher than the current HW supports.
Solution
Check the HW specifications for the supported powers and insure that the level is not exceeded.
The M5e 1 Watt units support power from 5 dBm to 30 dBm.
The M5e-Compact units support power from 10 dBm to 23 dBm.
FAULT_MSG_INVALID_FREQ_RECEIVED - 104h
Cause
A message was received by the reader to set the frequency outside the supported range
Solution
Make sure the host does not set the frequency outside this range or any other locally supported ranges.
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
Cause
The reader received a valid command with an unsupported or invalid value within this command.
For example, currently the module supports two antennas, 1 and 2. If the module receives a message with an antenna value other than 1 or 2, it returns this error.
Solution
Make sure the host sets all the values in a command according to the values published in this document.
Appendix C: Error Messages
213
214
Common Error Messages
FAULT_MSG_POWER_TOO_LOW - 106h
Cause
A message was received to set the read or write power to a level that is lower than the current HW supports.
Solution
Check the HW specifications for the supported powers and insure that level is not exceeded. The M5e supports powers between 5 and 30 dBm. The M5e-Compact units support power from 10 dBm to 23 dBm.
FAULT_UNIMPLEMENTED_FEATURE - 109h
Cause
Attempting to invoke a command not supported on this firmware or hardware.
Solution
Check the command being invoked against the documentation.
FAULT_INVALID_BAUD_RATE - 10Ah
Cause
When a Set Baud Rate (0x06h) command is issued for a rate that is not specified in the
Baud Rate table, this error message is returned.
Solution
Check the table of specific baud rates and select a baud rate. Send the baud rate in the hex format. See
Appendix C: Error Messages
Common Error Messages
FAULT_INVALID_REGION – 10Bh
Cause
The region code specified in
is invalid or not supported in the currently running application program or not supported in the current version of code.
Solution
Check the supported
Appendix C: Error Messages
215
Bootloader Faults
Bootloader Faults
The following table lists the common faults discussed in this section.
Fault Message
FAULT_BL_INVALID_IMAGE_CRC
FAULT_BL_INVALID_APP_END_ADDR
Code
200h
201h
FAULT_BL_INVALID_IMAGE_CRC – 200h
Cause
When a Verify Image CRC (0x08), or Boot Firmware (0x02) command is issued, the reader checks the image stored in flash and returns this error if the calculated CRC is different than the one stored in flash.
Solution
The exact reason for the corruption could be that the image loaded in flash was corrupted during the transfer or corrupted for some other reason.
To fix this problem, reload the application code in flash.
FAULT_BL_INVALID_APP_END_ADDR – 201h
Cause
When a Verify Image CRC (0x08), or Boot Firmware (0x02) command is issued, the reader checks the image stored in flash and returns this error if the last word stored in flash does not have the correct address value.
Solution
The exact reason for the corruption could be that the image loaded in flash got corrupted during the transfer or, corrupted for some other reason.
To fix this problem, reload the application code in flash.
216
Appendix C: Error Messages
Flash Faults
Flash Faults
The following table lists the common faults discussed in this section.
Fault Message
FAULT_FLASH_BAD_ERASE_PASSWORD – 300h
FAULT_FLASH_BAD_WRITE_PASSWORD – 301h
FAULT_FLASH_UNDEFINED_ERROR – 302h
FAULT_FLASH_ILLEGAL_SECTOR – 303h
FAULT_FLASH_WRITE_TO_NON_ERASED_AREA – 304h
FAULT_FLASH_WRITE_TO_ILLEGAL_SECTOR – 305h
FAULT_FLASH_VERIFY_FAILED – 306h
Code
300h
301h
302h
303h
304h
305h
306h
FAULT_FLASH_BAD_ERASE_PASSWORD – 300h
Cause
A command was received to erase some part of the flash but the password supplied with the command was incorrect.
Solution
Make sure that you have the correct password for the flash sector.
section for more information about the flash passwords and
sectors.
FAULT_FLASH_BAD_WRITE_PASSWORD – 301h
Cause
A command was received to write some part of the flash but the password supplied with the command was not correct.
Appendix C: Error Messages
217
Flash Faults
218
Solution
Make sure that you have the correct password for the flash sector.
Check the
for more information about the flash passwords and sectors.
FAULT_FLASH_UNDEFINED_ERROR – 302h
Cause
This is an internal error and it is caused by a software problem in module.
Solution
Contact support at [email protected].
FAULT_FLASH_ILLEGAL_SECTOR – 303h
Cause
An erase or write flash command was received with the sector value and password not matching.
Solution
Make sure that you have the correct password for the flash sector.
Go to
for more information about the flash passwords and sectors.
FAULT_FLASH_WRITE_TO_NON_ERASED_AREA – 304h
Cause
The module received a write flash command to an area of flash that was not previously erased.
Solution
Erase that sector of flash and then, try and rewrite to it.
Appendix C: Error Messages
Flash Faults
FAULT_FLASH_WRITE_TO_ILLEGAL_SECTOR – 305h
Cause
The module received a write flash command to write across a sector boundary that is prohibited.
Solution
If the data spans two sectors, separate the data into two messages.
FAULT_FLASH_VERIFY_FAILED – 306h
Cause
The module received a write flash command that was unsuccessful because data being written to flash contained an uneven number of bytes.
Solution
Verify that the data being sent is an even number of bytes.
Appendix C: Error Messages
219
Protocol Faults
The following table lists the common faults discussed in this section.
Fault Message Code
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
FAULT_WRITE_PASSED_LOCK_FAILED – 403h
FAULT_PROTOCOL_NO_DATA_READ – 404h
FAULT_PROTOCOL_WRITE_FAILED – 406h
406h
FAULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h
407h
FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h
FAULT_PROTOCOL_INVALID_ADDRESS – 409h
404h
405h
408h
409h
FAULT_GENERAL_TAG_ERROR – 40Ah
402h
403h
40Ah
40Bh
FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch
FAULT_PROTOCOL_KILL_FAILED - 40Eh
400h
401h
40Ch
40Eh
FAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh
FAULT_PROTOCOL_INVALID_EPC – 410h
40Fh
410h
FAULT_PROTOCOL_INVALID_NUM_DATA – 411h
FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
411h
420h
FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC -
423h
FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
FAULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh
424h
42Bh
FAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh
FAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h
42Fh
430h
Protocol Faults
220
Appendix C: Error Messages
Protocol Faults
FAULT_NO_TAGS_FOUND – 400h
Cause
A command was received (such as like read, write, or lock) but the operation failed. There are many reasons that can cause this error to occur.
Here is a list of possible reasons that could be causing this error:
No tag in the RF field
Read/write power too low
Antenna not connected
Tag is weak or dead
Solution
Make sure there is a good tag in the field and all parameters are set up correctly. The best way to check this is to try few tags of the same type to rule out a weak tag. If none passed, then it could be SW configuration such as protocol value, antenna, and so forth, or a placement configuration like a tag location.
FAULT_NO_PROTOCOL_DEFINED – 401h
Cause
A command was received to perform a protocol command but no protocol was initially set. The reader powers up with no protocols set.
Solution
A Set Current Tag Protocol (63h) command must be sent followed by resending the desired command.
FAULT_INVALID_PROTOCOL_SPECIFIED – 402h
Cause
A Set Current Tag Protocol (63h) command was received for a protocol value that is not supported with the current version of SW.
Appendix C: Error Messages
221
222
Protocol Faults
Solution
This value is invalid or this version of SW does not support the protocol value. Check the documentation for the correct values for the protocols in use.
FAULT_WRITE_PASSED_LOCK_FAILED – 403h
Cause
During a Write Tag Data for ISO18000-6B or UCODE, if the lock fails, this error is returned. The write command passed but the lock did not. This could be a bad tag.
Solution
Try to write a few other tags and make sure that they are placed in the RF field.
FAULT_PROTOCOL_NO_DATA_READ – 404h
Cause
A Read Tag ID or Data command was sent but did not succeed.
Solution
The tag used has failed or does not have the correct CRC. Try to read a few others to check the HW/SW configuration.
FAULT_AFE_NOT_ON – 405h
Cause
A command was received for an operation, like read or write, but the RF cannot turn on because the Region and/or Protocol have not been set..
Solution
Call
Set Current Tag Protocol (93h)
operation and tag protocol, respectively.
Appendix C: Error Messages
Protocol Faults
FAULT_PROTOCOL_WRITE_FAILED – 406h
Cause
This fault can occur when an operation such as write, lock, kill, set password, or initialize, fails. There are many reasons for failure.
Solution
Check that the tag is good and try another operation on a few more tags.
F
AULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h
Cause
A command was received which is not supported by a protocol.
Solution
Check the documentation for the supported commands and protocols.
FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h
Cause
In EPC0+, the first two bits determine the tag ID length. If the first two bits are 0b00, then the tag ID must be 96-bits. Otherwise the tag ID is 64 bits.
Solution
Make sure that the first two bit have the correct values depending in the Tag ID length.
FAULT_PROTOCOL_INVALID_ADDRESS – 409h
Cause
A command was received attempting to access an invalid address in the tag data address space.
Appendix C: Error Messages
223
224
Protocol Faults
Solution
Make sure that the address specified is within the scope of the tag data address space and available for the specific operation. The protocol specifications contain information about the supported addresses.
FAULT_GENERAL_TAG_ERROR – 40Ah
Cause
This error is used by the M5e GEN2 module. This fault can occur if the read, write, lock, or kill command fails. This error can be internal or functional.
Solution
Make a note of the operations you were performing and contact ThingMagic at http:// support.thingmagic.com
FAULT_DATA_TOO_LARGE – 40Bh
Cause
A command was received to Read Tag Data with a data value larger than expected or it is not the correct size.
Solution
Check the size of the data value in the message sent to the reader.
FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch
Cause
An incorrect kill password was received as part of the Kill Tag (26h) command.
Solution
Check the password.
Appendix C: Error Messages
Protocol Faults
FAULT_PROTOCOL_KILL_FAILED - 40Eh
Cause
Attempt to kill a tag failed for an unknown reason
Solution
Check tag is in RF field and the kill password.
FAULT_PROTOCOL_BIT_DECODING_FAILED - 40Fh
Cause
Attempt to operate on a tag with an EPC length greater than the Maximum EPC length setting.
Solution
Call
to set the Max EPC to 496 bits..
FAULT_PROTOCOL_INVALID_EPC – 410h
Cause
This error is used by the M5e GEN2 module indicating an invalid EPC value has been specified for an operation. This fault can occur if the read, write, lock, or kill command fails.
Solution
Check the EPC value that is being passed in the command resulting in this error.
FAULT_PROTOCOL_INVALID_NUM_DATA – 411h
Cause
This error is used by the M5e GEN2 module indicating invalid data has been specified for an operation. This fault can occur if the read, write, lock, or kill command fails.
Appendix C: Error Messages
225
Protocol Faults
Solution
Check the data that is being passed in the command resulting in this error.
FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h
FAULT_GEN2_PROTOCOL_MEMORY_OVERRUN_BAD_PC - 423h
FAULT_GEN2 PROTOCOL_MEMORY_LOCKED - 424h
F
AULT_GEN2 PROTOCOL_INSUFFICIENT_POWER - 42Bh
FAULT_GEN2 PROTOCOL_NON_SPECIFIC_ERROR - 42Fh
FAULT_GEN2 PROTOCOL_UNKNOWN_ERROR - 430h
226
Appendix C: Error Messages
Analog Hardware Abstraction Layer Faults
Analog Hardware Abstraction Layer Faults
FAULT_AHAL_INVALID_FREQ – 500h
Cause
A command was received to set a frequency outside the specified range.
For example, in North America the frequency range is from 902 MHz to 928 MHz.
Solution
Check the values you are trying to set and be sure that they fall within this range.
FAULT_AHAL_CHANNEL_OCCUPIED – 501h
Cause
With LBT enabled an attempt was made to set the frequency to an occupied channel.
Solution
Try a different channel.
FAULT_AHAL_TRANSMITTER_ON – 502h
Cause
Checking antenna status while CW is on is not allowed.
Solution
Do not perform antenna checking when CW is turned on.
Appendix C: Error Messages
227
Analog Hardware Abstraction Layer Faults
228
FAULT_ANTENNA_NOT_CONNECTED – 503h
Cause
An attempt was made to transmit on an antenna which did not pass the antenna detection when antenna detection was turned on.
Solution
Connect a detectable antenna (antenna must have some DC resistance).
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
Cause
The module has exceeded the maximum or minimum operating temperature and will not allow an RF operation until it is back in range.
Solution
Take steps to resolve thermal issues with module:
Reduce duty cycle
Add heat sink
FAULT_HIGH_RETURN_LOSS – 505h
Cause
The module has detected a high return loss and has ended RF operation to avoid module damage.
Solution
Take steps to resolve high return loss on receiver:
Make sure antenna VSWR is within module specifications
Make sure antennas are correctly attached before transmitting
Appendix C: Error Messages
Analog Hardware Abstraction Layer Faults
Check environment to ensure no occurrances of high signal reflection back at antennas.
FAULT_AHAL_INVALID_ANTENA_CONFIG – 507h
Cause
An attempt to set an antenna configuration that is not valid based on the current
GPIO as
Antenna Switch
setting applied using
Solution
Use the correct antenna setting or change the reader configuration.
Appendix C: Error Messages
229
Tag ID Buffer Faults
Tag ID Buffer Faults
The following table lists the common faults discussed in this section.
Fault Message Code
FAULT_TAG_ID_BUFFER_NOT_ENOUGH_TAGS_AVAILABLE – 600h
600h
FAULT_TAG_ID_BUFFER_FULL – 601h
601h
FAULT_TAG_ID_BUFFER_REPEATED_TAG_ID – 602h
FAULT_TAG_ID_BUFFER_NUM_TAG_TOO_LARGE – 603h
602h
603h
FAULT_TAG_ID_BUFFER_NOT_ENOUGH_TAGS_AVAILA
BLE – 600h
Cause
A command was received to get a certain number of tag ids from the tag id buffer. The reader contains less tag ids stored in its tag id buffer than the number the host is sending.
Solution
Send a Get Tag ID Buffer command to ascertain how many tags are in the buffer. You can get the exact number of tags as long as they are less than or equal to the number returned by the previous command.
FAULT_TAG_ID_BUFFER_FULL – 601h
Cause
The tag id buffer is full.
Solution
Send Clear Tag ID Buffer or Get Tag ID Buffer command with the number of tags to
230
Appendix C: Error Messages
Tag ID Buffer Faults
FAULT_TAG_ID_BUFFER_REPEATED_TAG_ID – 602h
Cause
The module has an internal error. One of the protocols is trying to add an existing TagID to the buffer.
Solution
Report this problem to ThingMagic at http://support.thingmagic.com.
FAULT_TAG_ID_BUFFER_NUM_TAG_TOO_LARGE – 603h
Cause
The module received a request to retrieve more tags than is supported by the current version of the software.
Solution
Locate the maximum number of supported tags in the TagID buffer in this document
Appendix C: Error Messages
231
System Errors
System Errors
FAULT_SYSTEM_UNKNOWN_ERROR – 7F00h
Cause
The error is internal.
Solution
Make note of the operations you were executing and contact ThingMagic at http:// support.thingmagic.com.
FAULT_TM_ASSERT_FAILED – 7F01h
Cause
An unexpected Internal Error has occurred.
Solution
The error will cause the module to switch back to Bootloader mode. When this occurs make note of the operations you were executing, save FULL error response and contact
ThingMagic at [email protected].
232
Appendix C: Error Messages
Appendix D: Deprecated and Modified
Commands
The following contains the deprecated versions of Serial commands grouped by the release they were deprecated in. These commands are still supported for backward compatibility. For new development the new formats for each, as specified in
, should be used.
Appendix D: Deprecated and Modified Commands
233
Release Version 1.0.34
Release Version 1.0.34
Read Tag Single (21h)
If a tag is read using the currently set tag protocol, its EPC is returned in the tag ID section of the packet. If no tag is read, a fault code is reported. The Read Tag Single command takes a 16-bit timeout value in milliseconds.
The following example shows a timeout of 1000 ms (0x03E8):
FF
SOH
02
Length
21
OpCode
03 E8
Timeout (ms)
D5
CRC
09
The response to this command is slightly different depending upon the number of bits in the tag ID of the current protocol that is selected. The general response format is shown here:
FF
SOH
M+2
Length
21
OpCode
00 00
Status
M bytes
Tag ID
??
??
??
??
TagCRC CRC
For example, the following response packet for an EPC0 64-bit tag is sent back. Notice that the Tag CRC follows the tag ID field for all protocols:
FF 0A 21 00 00 C8
SOH Lengt h
OpCod e
Status
1.Tag CRC – Calculated on the tag ID field only.
2.CRC – Calculated on the entire message packet.
05 07 A8
Tag ID
00 84 C4 FF 9E E0
1
Tag CRC
F7
2
CRC
25
Note
It is important to have a valid protocol selected. To select a protocol, use the
Set Tag Protocol
command. This command will not work correctly if there are multiple tags in the RF field, use the
Read Tag Multiple
command instead.
234
Appendix D: Deprecated and Modified Commands
Release Version 1.0.34
Read Tag ID Multiple (22h)
The Read Tag ID Multiple command performs a search for the specified period of time then returns the number of tags that have been found. Afterwards, multiple Get Tag ID
Buffer
commands can be sent to receive the found tag IDs. Each protocol defines its own search method.
FF
SOH
02
Length
The return provides the following:
22
OpCode
03 E8
Timeout (ms)
E5
CRC
6A
FF
SOH
01
Length
22
OpCode
00
Status
00 02
# Tag IDs Found
46
CRC
BA
Write Tag Data (24h)
The Write Tag Data command writes into the data section of the tag. To write the tag ID, use the Write Tag ID command.
FF
SOH
M + N + 7
Length
24
OpCod e
03 E8
Timeout (ms)
00
Lock Bit
00 00 00 00
Address
M bytes
Tag ID (M bytes)
N bytes
Data to Write
??
CRC
??
Appendix D: Deprecated and Modified Commands
235
Release Version 1.0.34
GEN2
For Gen2, if Option=00, the write tag data is performed without the select option with the following format:
FF
SOH
N+8
Length
24
OpCode
03 E8
Timeout (ms)
00
Option
00 00 00 02
Address
01
MemBank
N bytes
Data to Write
??
CRC
??
In the previous example, the reader can singulate a tag with Q=0 and would try to write N bytes of data into the first tag it can see, starting at the address 0x2 of EPC MemBank
(the first word of the tag’s EPC).
If Option=01, the write tag data is performed with the select option that enables you to choose a tag from a population of tags based on its Tag ID with the following format:
FF
SOH
M+N+13
Length
24
OpCod e
03 E8
Timeout (ms)
01
Option
00 00 00 02
Address
00
MemBank
00 00 00
Access Password
00
60h
Tag ID Length
M bytes
Tag ID (M bytes)
N bytes
Data to Write
??
CRC
??
In this example, if N=4, the reader issues a Select command to singulate the desired tag and then would write 4 bytes of data into the tag memory of a 96-bit tag with the specified
Tag ID, starting at the address 0x2 of the Reserved MemBank (the first word of the Kill
Password of the tag).
Note
In both examples, N is a variable value that is an even, nonzero number less than 32.
The 32-bit Address field is the offset from the MemBank origin, in 16-bit words, where the contents of the Data field is written. It corresponds to the
WordPtr
argument in the Gen2 command specification.
The 8-bit MemBank field specifies which of the tag’s memory banks is to be addressed. It corresponds to the
Gen2
argument of the same name. Its values are as follows.
236
Appendix D: Deprecated and Modified Commands
Release Version 1.0.34
MemBan k
0x00
0x01
0x02
0x03
Description
Reserved
EPC
TID
User
For more information about the MemBank structure and the memory map of the Gen2 tag, please refer to the EPC Global GEN2 protocol specification. This command is not supported by the EPC1 protocol.
Lock Tag (25h)
The Lock Tag command locks a specific address in the tag data section. The ID of the tag, the address to lock, and a password for killing the tag need to be provided.
FF
SO
H
M + P + 6
Length
25
OpCode
03 E8
Timeout
(ms)
P bytes
Password
00 00 00
Address
08 M bytes
Tag ID (M bytes)
??
CRC
??
For the GEN2 protocol, the command format is as follows.
FF
SOH
0A
Length
25
OpCode
03 E8
Timeout (ms)
11 22 33
Access Password
44 11 22
Mask Bits
11 22
Action Bits
??
??
CRC
The Lock command sends a command sequence including Lock described in the Gen2 specification. The 32-bit Access Password argument must contain the access password that was written previously to word addresses 0x02 and 0x03 (bit addresses 0x20-0x3F) of the tag.
The Mask and Action bits correspond to the identically named fields described in Section
6.3.2.10.3.5 of the Gen2 specification. Each of these 10-bit fields is right-aligned (LSBaligned) in the corresponding 16-bit argument to the serial command, as shown in the following table. These fields are passed directly to the tag.
Appendix D: Deprecated and Modified Commands
237
Release Version 1.0.34
Bit
15 14
Mask
X
Actio n
X
Unused
X
X
First Byte (0x11 above)
13 12 11 10 9
X
X
X
X
X
X
X
X
Kill Pwd
L L
R/W
8 7
Perm R/W
6
Access Pwd
L L
Perm
Second Byte (0x22 above)
5 4 3 2 1
EPC Mem
L L
W Perm
TID Mem
L L
W Perm W
0
User Mem
L L
Perm
Where a Mask bit is specified as “L,” a “1” in that bit indicates that the corresponding bit in the Action field is set or cleared. A “0” indicates that the corresponding bit in the Action field should be ignored.
Where an Action bit is specified as “R/W,” a “1” indicates that reading and writing should be locked. A “W” indicates that only writing should be locked.
Note
Adding ‘0000’ in the
Action
field unlocks the memory bank.
A “Perm” bit sets the permalock state of the corresponding “R/W” or “W” bit, which permanently programs the lock status of that bit on the tag. An Action bit has no effect unless the corresponding Mask bit is set. An “X” in the above table indicates an ignored bit. For more detailed information about these fields, please refer to the Gen2 specification.
A tag whose access password is zero transitions directly from the acknowledged state to the secured state without first stopping in the open state. No password check is required.
In other words, locking a tag has no effect if its access password is set to zero (unless it is permalocked). The access password can be set using the Write Tag Data command.
Kill Tag (26h)
The Kill Tag command kills a tag. Since each protocol has a different format for the kill command, this is highly protocol dependent. As each new kill command becomes available, the message structure will be documented in this section.
For the GEN2 protocol, the following command format is used.
238
Appendix D: Deprecated and Modified Commands
Release Version 1.0.34
FF
SOH
07
Length
26
OpCode
03 E8
Timeout (ms)
11 22 33
Kill Password
44 00
RFU
??
CRC
??
The kill password must correspond to the kill password programmed in the tag.
Note
If the tag’s kill password is set to 0, the protocol does not allow the tag to be killed. A non-zero kill password must be set (using the
Write Tag Data
command) before the kill command succeeds. The RFU field should be set to 0.
Appendix D: Deprecated and Modified Commands
239
240
Release Version 1.0.34
Read Tag Data (28h)
The Read Tag Data command reads data from the tag. Because each protocol has different formats for reading / writing data, the address field may have different meanings.
The general format for the Read Tag Data command is shown in the following example.
The tag ID field can be either 8 or 12 bytes, depending on whether it is a 64-bit or 96-bit tag.
FF
SOH
M + 6
Length
28
OpCode
03 E8
Timeout (ms)
00 00 00
Address
10 M bytes
Tag ID (M bytes)
??
CRC
??
GEN2 Command and Response
The Read Tag Data command for the GEN2 protocol has the following format. This example reads the first 16-bit word of the EPC stored in a tag using the GEN2 protocol
Read
command.
FF
SOH
08
Length
28
OpCode
03 E8
Timeout (ms)
01
MemBank
00 00 00 02
Address
01
WordCount
??
CRC
??
Read Tag Data Command
The MemBank, Address, and WordCount fields correspond to the
MemBank
,
WordPtr
, and
WordCount
arguments to the GEN2 protocol Read command, respectively. The
MemBank options are listed in the
Refer to the EPC Global GEN2 protocol specification for more details about the tag memory map.
Appendix D: Deprecated and Modified Commands
Release Version 1.0.34
The response to the Read Data command for the GEN2 protocol has the following format.
FF
SOH
M
Length
28
OpCode
00
Status
00 01 …
Data
M ??
CRC
??
Read Tag Data Response
The length (M) of the data returned is twice the WordCount value in the original command because the return packet length is counted in bytes.
Get Read TX Power (62h)
The Get Read TX Power command returns the current TX power for reading tags, in centi-dBm:
FF
SOH
00
Length
62
OpCode
1D
CRC
6D
Microprocessor reply is similar to the Set Read TX Power command. In this example,
0x09C4 corresponds to 2500, which is 25.00 dBm. The default read power is set to 30 dBm:
FF
SOH
02
Length
62
OpCode
00
Status
00 09 C4
Power in centi-dBm
1F
CRC
B7
Get Write TX Power (64h)
The Get Write TX Power command gets the current power level used for TX write commands:
Appendix D: Deprecated and Modified Commands
241
242
Release Version 1.0.34
FF
SOH
00
Length
64
OpCode
1D
CRC
6B
Microprocessor reply is similar to Set Write TX Power. The default Write TX power is set to 30 dBm:
FF
SOH
02
Length
64
OpCode
00
Status
00 0A 5A
Power in centi-dBm
AE
CRC
89
Get Current Region (67h)
The Get Current Region command gets the current region set in the reader. Currently available region codes are shown in the following table. Details on the Regulatory
Compliance for each region can be found in
::
Region codes
Regio n
NA
EU
EU2
EU3
KR
Open
LBT Support/
Default
No
Yes/On
No
Yes/Off
No
Yes/Off
Code
0x01
0x02
0X07
0x08
0x03
0xFF
Appendix D: Deprecated and Modified Commands
Release Version 1.0.34
To get the current region, send the following command:
FF
SOH
00
Length
67
OpCode
1D
CRC
68
The command generates the following reply, which indicates that the reader is set to the
NA region:
FF
SOH
01
Length
67
OpCode
00
Status
00 01
Region
B4
CRC
80
Get Transmit Mode (6Ah)
The Get Transmit Mode command returns the tranmit modethe M5e is current set to.
The available transmit modes are shown in the following table:
Available Transmit Modes
Hex
0x0000
0x0001
Transmit Mode
High performance mode (disables low power mode)
Low power mode (disables high performance mode)
Send the following command to get the currrent transmit mode:
FF
SOH
00
Length
6A
OpCode
1D
CRC
65
The example reply shows the current transmit mode setting:
FF
SOH
02
Length
6A
OpCode
00
Status
00 00 01
Transmit Mode
BF
CRC
D3
Appendix D: Deprecated and Modified Commands
243
244
Release Version 1.0.34
Set Current Region (97h)
The Set Current Region command sets the current region for use in the reader. The list of region codes are found in
Region codes
. However, the module is able to support only a limited subset of those regions.
Setting the region performs the following:
1.
Frequency hop table is set to the default for the region.
2.
Power limits are applied to ensure unit does not send out too much power.
3.
Any other region specific settings are enforced.
For example, to set the region to KR:
FF
SOH
01
Length
97
OpCode
03
Region
4B
CRC
BE
Set Transmit Mode (9Ah) [M5e Only]
Use the Set Transmit Mode command to set the transmit mode the M5e will use. The available transmit modes are shown in the following table:
Available Transmit Modes
Hex
0x0000
0x0001
Transmit Mode
High performance mode (disables low power mode)
Low power mode (disables high performance mode)
Send the following to enable the Low power transmit mode:
FF
SOH
02
Length
9A
OpCode
00 01
Transmit Mode
C0
CRC
50
Note
The default setting is high performance mode (disables low power mode).
Appendix D: Deprecated and Modified Commands
Release Version 1.0.37.27
Release Version 1.0.37.27
Set Reader Configuration(9Ah)
For the deprecated version of this command see Appendix D:
The Set Reader Configuration command is used to set several configuration options on the reader. The configuration options, defined in the table below are enabled bitwise, although the option value is specified in hexidecimal (2 bytes). One example configuration and the corresponding Options value is specified in the command example below. For other combinations the hex value for Options will need to be calculated by OR’ing the bits for each setting.
Available Configuration Options
Option Bit/
Mode
Bit 0
Transmit Mode
Bit 1
EPC Length
Bit Value
(4 LSBs shown)
XXX02 (Default)
XXX12
XX0X2 (Default)
XX1X2
Reader Configuration setting
Low Power Mode (disables high performance mode)
Maximum EPC length of 96 bits
Maximum EPC length of 496 bits
Send the following to enable the Low power transmit mode and support for EPC values up to 496 bits:
FF
SOH
02
Length
9A
OpCode
00
Options
03 C0
CRC
52
Appendix D: Deprecated and Modified Commands
245
Release Version 1.0.37.27
Get Reader Configuration(6Ah)
For the deprecated version of this command see Appendix D:
The Get Reader Configuration command returns the current reader configuration as
Set Transmit Mode (9Ah) [M5e Only]
Send the following command to get the current transmit mode:
FF
SOH
00
Length
6A
OpCode
1D
CRC
65
The example reply shows the current reader configuration Options setting:
FF
SOH
02
Length
6A
OpCode
00
Status
00 00
Options
01 BF
CRC
D3
246
Appendix D: Deprecated and Modified Commands
Appendix E: Environmental
Considerations
This Appendix details environmental factors that should be considered relating to reader performance and survivability.
ElectroStatic Discharge (ESD) Considerations
W A R N I N G !
The M5e antenna ports may be susceptible to damage from Electrostatic
Discharge (ESD). Equipment failure can result if the antenna or communication ports are subjected to ESD. Standard ESD precautions should be taken during installation to avoid static discharge when handling or making connections to the M6 reader antenna or communication ports. Environmental analysis should also be performed to ensure static is not building up on and around the antennas, possibly causing discharges during operation.
ESD Damage Overview
In M5e-based reader installations where readers have failed without known cause, based on anecdotal information ESD has been found to be the most common cause. Failures due to ESD tend to be in the M5E power amplifier section (PA). PA failures typically manifest themselves at the software interface in the following ways:
RF operations (read, write, etc.) respond with status code 0x7F01 - indicating a a fatal error. This is typically due the the module not being able to reach the target power level due to PA damage.
RF operations (read, write, etc.) respond with status code 0x0505 even when a known good antenna is attached.
Unexpected status code 0x0101, indicating command not supported, when that command had worked just fine shortly before. The reason a command becomes suddenly not supported is that the reader, in the course of its self protection routines,
247
Appendix E: Environmental Considerations
ElectroStatic Discharge (ESD) Considerations
248 has returned to the bootloader to prevent any further damage. This jump to boot loader caused by power amp damage occurs at the start of any read tag commands.
Ultimately determining that ESD is the root cause of failures is difficult because it relies on negative result experiments, i.e. it is the lack of failure after a configuration change, rather than a positive flag wave that says “I’m ESD”. Such flag waves are sometimes, but only sometimes, available at the unpackaged transistor level under high power microscopy.
The remoteness of microscopic examination from the installed field failures is indicative of the high cost of using such analysis methods for chasing down ESD issues. Therefore most ESD issue resolutions will be using the negative result experiments to determine success.
ESD discharges come with a range of values, and like many things in life there is the
“matter of degree”. For many installations, the M5E has been successfully deployed and operates happily. For these, there is no failure issue, ESD or otherwise. For a different installation that with bare M5E, has a failure problem from ESD, there will be some distribution of ESD intensities occurring. Without knowledge of a limit in the statistics of those intensities, there may always be the bigger zap waiting in the wings. For the bare
M5E equipped with the mitigation methods described below, there will always be the rouge ESD discharge that exceeds any given mitigation, and results in failure.
Fortunately, many installations will have some upper bound on the value of ESD events given the geometry of that installation.
Several sequential steps are recommended for a) determining the ESD is the likely cause of a given group of failures, and b) enhancing the M5E’s environment to eliminate ESD failures. The steps vary depending on the required M5E output power in any given application.
Identifying ESD as the Cause of Damaged Readers
The following are some suggested methods to determine if ESD is a cause of reader failures, i.e. ESD diagnostics. Please remember- some of these suggestions have the negative result experiment problem.
Return failed units for analysis. Analysis should be able to say if it is the power amplifier that has in fact failed, but won’t be able to definitively identify that the cause is ESD. However, ESD is one of the more common causes of PA failure.
Measure ambient static levels with static meter.
AlphaLabs SVM2
is such a meter, but there are others. You may be surprised at the static potentials floating detected.
However, high static doesn’t necessarily mean discharges, but should be considered cause for further investigation. High levels that keep changing are highly indicative of discharges.
Touch some things around the antenna, and operating area. If you feel static discharges, that qualitatively says quite a bit about what is in front of the antenna.
Appendix E: Environmental Considerations
ElectroStatic Discharge (ESD) Considerations
What actually gets to the M5E is also strongly influenced by the antenna installation, cabling, and grounding discussed above.
Use the mean operating time statistic before and after one or more of the changes listed below to quantitatively determine if the change has resulted in an improvement.
Be sure to restart your statistics after the change.
Common Installation Best Practices
The following are common installation best practices which will ensure the readers isn’t being unnecessarily exposed to ESD in even low risk environments. These should be applied to all installations, full power or partial power, ESD or not:
Insure that M5E, M5E enclosing housing (e.g. Vega reader housing), and antenna ground connection are all grounded to a common low impedance ground.
Verify R-TNC knurled threaded nuts are tight and stay tight. Don’t use a thread locking compound that would compromise the grounding connection of the thread to thread mate. If there is any indication that field vibration might cause the R-TNC to loosen, apply RTV or other adhesive externally.
Use antenna cables with double shield outer conductors, or even full metallic shield semirigid cables. ThingMagic specified cables are double shielded and adequate for most applications. ESD discharge currents flowing ostensibly on the outer surface of a single shield coaxial cable have been seen to couple to the inside of coaxial cables, causing ESD failure. Avoid RG-58. Prefer RG-223.
Minimize ground loops in coaxial cable runs to antennas. Having the M5E and antenna both tied to ground (per item 1) leads to the possibility of ground currents flowing along antenna cables. The tendency of these currents to flow is related to the area of the conceptual surface marked out by the antenna cable and the nearest continuous ground surface. When this conceptual surface has minimum area, these ground loop current are minimized. Routing antenna cables against grounded metallic chassis parts helps minimize ground loop currents.
Keep the antenna radome in place. It provides significant ESD protection for the metallic parts of the antenna, and protects the antenna from performance changes due to environmental accumulation.
Keep careful track of serial numbers, operating life times, numbers of units operating.
You need this information to know that your mean operating life time is. Only with this number will you be able to know if you have a failure problem in the first place, ESD or otherwise. And then after any given change, whether things have improvement or not. Or if the failures are confined to one instantiation, or distributed across your population.
Appendix E: Environmental Considerations
249
ElectroStatic Discharge (ESD) Considerations
250
Raising the ESD Threshold
For applications where full M5E power is needed for maximum tag read range and ESD is suspected the following components are recommended additions to the installation to raise the level of ESD the reader can tolerate:
Select or change to an antenna with all radiating elements grounded for DC. The MTI
MT-262031-T(L,R)H-A is such an antenna. The Laird IF900-SF00 and CAF95956 are not such antennas. The grounding of the antenna elements dissipates static charge leakage, and provides a high pass characteristic that attenuates discharge events. (This also makes the antenna compatible with the M5e antenna detect methods.)
Install a Minicircuits SHP600+ high pass filter in the cable run at the M5E (or Vega or other finished reader) end. This additional component will reduce transmit power by
0.4 dB which may affect read range in some critical applications. However the filter will significantly attenuate discharges and improve the M5E ESD survival level.
Note
The SHP600+ is not rated for the full +30 dBm output of the M5E of Vega reader at +85 degree C. Operation at reduced temperature has been anecdotally observed to be OK, but has not been fully qualified by
ThingMagic.
Install a Diode Clamp* circuit immediately outboard from the SHP600 filter. This will reduce transmit power by an additional 0.4 dB, but in combination with the SHP600 will further improve the M5E ESD survival level. * Not yet productized. Needs DC power, contact [email protected] for details.
Further ESD Protection for Reduced RF Power Applications
In addition to the protective measures recommended above, for applications where reduced M5E RF power is acceptable and ESD is suspected the following protective measures can also be applied:
Install a one watt attenuator with a decibel value of +30 dBm minus the dBm value needed for tag power up. Then run the reader at +30 dBm instead of reduced transmit power. This will attenuate inbound ESD pulses by the installed decibel value, while keeping the tag operation generally unchanged. Attenuators of 6 dB have been shown to not adversely effect read sensitivity. Position the attenuator as close to the M5E as feasible.
As described above add the SHP600 filter immediately adjacent to the attenuator, on the antenna side.
Add Diode Clamp, if required, adjacent to the SHP600, on the antenna side.
Appendix E: Environmental Considerations
Variables Affecting Performance
Variables Affecting Performance
Reader performance may be affected by the following variables, depending on the site where your Reader is being deployed:
Environmental
Reader performance may be affected by the following environmental conditions:
Metal surfaces such as desks, filing cabinets, bookshelves, and wastebaskets may enhance or degrade Reader performance.
Antennas should be mounted far away from metal surfaces that may adversely affect the system performance.
Devices that operate at 900 MHz, such as cordless phones and wireless LANs, can degrade Reader performance. The Reader may also adversely affect the performance of these 900 MHz devices.
Moving machinery can interfere the Reader performance. Test Reader performance with moving machinery turned off.
Fluorescent lighting fixtures are a source of strong electromagnetic interference and if possible should be replaced. If fluorescent lights cannot be replaced, then keep the Reader cables and antennas away from them.
Coaxial cables leading from the Reader to antennas can be a strong source of electromagnetic radiation. These cables should be laid flat and not coiled up.
Tag Considerations
There are several variables associated with tags that can affect Reader performance:
Application Surface: Some materials, including metal and moisture, interfere with tag performance. Tags applied to items made from or containing these materials may not perform as expected.
Appendix E: Environmental Considerations
251
Tag Orientation: Reader performance is affected by the orientation of the tag in the antenna field. The ThingMagic antenna is circularly polarized, so it reads face-to but not edge-to.
Tag Model: Many tag models are available. Each model has its own performance characteristics.
Multiple Readers
The Reader adversely affect performance of 900 MHz devices. These devices also may degrade performance of the Reader.
Antennas on other Readers operating in close proximity may interfere with one another, thus degrading performance of the Readers.
Interference from other antennas may be eliminated or reduced by using either one or both of the following strategies: w Affected antennas may be synchronized by a separate user application using a time-multiplexing strategy.
w Antenna power can be reduced by reconfiguring the RF Transmit Power setting for the Reader.
Note
Performance tests conducted under typical operating conditions at your site are recommended to help you optimize system performance.
252
Appendix E: Environmental Considerations
Download
Advertisement
Key features
High performance RFID reader
Supports various RFID tags, including Gen2 tags
Flexible communication options
Tag Singulation/Select functionality
Configurable frequency and power settings
Power management modes
Tag buffer for storing tag data
Custom tag commands
Flash memory for storing data
General Purpose Inputs/Outputs (GPIO)
Frequently asked questions
The Mercury5e and M5e-Compact offer two power modes: High Performance Mode and Low Power Mode. High Performance Mode provides the highest read performance, while Low Power Mode minimizes power consumption. You can select the appropriate mode based on your application requirements.
Tag Singulation/Select allows you to identify and select specific tags from a group of tags. The readers use different algorithms to achieve this, and you can configure the algorithms and parameters using the command set.
The readers have a built-in flash memory that you can access using the command set to store data, application configurations, or firmware images.
The readers support a variety of communication protocols, including USB (with native USB support), RS232, and TCP/IP. You can choose the appropriate protocol based on your application and system requirements.