SIMCom SIM7912G-M2 Command Manual
PDF
Document
Advertentie
Advertentie
lF
ile
ia
Series_AT
SI
M
C
om
C
on
f
id
e
nt
SIM7906_SIM7912
Command Manual _V1.01
Smart Machine Smart Decision
SIM7906_SIM7912 Series_AT Command Manual
Version:
1.01
Date:
2019-11-21
Status:
Release
Document ID:
SIM7906_SIM7912 Series_AT Command Manual_V1.01
ia
lF
ile
Document Title:
General Notes
Copyright
C
on
f
id
e
nt
SIMCom offers this information as a service to its customers, to support application and engineering efforts
that use the products designed by SIMCom. The information provided is based upon requirements
specifically provided to SIMCom by the customers. SIMCom has not undertaken any independent search
for additional relevant information, including any information that may be in the customer’s possession.
Furthermore, system validation of this product designed by SIMCom within a larger electronic system
remains the responsibility of the customer or the customer’s system integrator. All specifications supplied
herein are subject to change.
C
om
This document contains proprietary technical information which is the property of SIMCom Limited.,
copying of this document and giving it to others and the using or communication of the contents thereof,
are forbidden without express authority. Offenders are liable to the payment of damages. All rights reserved
in the event of grant of a patent or the registration of a utility model or design. All specification supplied
herein are subject to change without notice at any time.
SI
M
Copyright © Shanghai SIMCom Wireless Solutions Ltd. 2019
SIM7906_SIM7912 Series_AT Command Manual_V1.01
1
2019-11-21
Smart Machine Smart Decision
Version History
Date
Chapter
What is new
V1.00
2019-05-28
New version
V1.01
2019-06-12
Add Sim7912 support
V1.01
2019-09-16
Modify this command
SI
M
C
om
C
on
f
id
e
nt
ia
4.19 AT+SIMEI
lF
ile
Version
SIM7906_SIM7912 Series_AT Command Manual_V1.01
2
2019-11-21
Smart Machine Smart Decision
Contents
lF
ile
V e r s i o n H i s t o r y ........................................................................................................................... 2
C o n t e n t s ............................................................................................................................................ 3
1 Introduction...................................................................................................................................... 8
1.1
Scope ...................................................................................................................................................... 8
1.2
References .............................................................................................................................................. 8
1.3
Terms and abbreviations ......................................................................................................................... 8
1.4
Definitions and conventions ................................................................................................................... 9
AT Interface Synopsis .....................................................................................................................11
ia
2
Interface settings ...................................................................................................................................11
2.2
AT command syntax ..............................................................................................................................11
2.3
Information responses .......................................................................................................................... 12
3
nt
2.1
AT Commands According V.25TER .............................................................................................. 13
A/
3.2
ATH
Repeat last command.................................................................................................................... 13
Disconnect existing call ............................................................................................................ 13
3.3
ATI
Display product identification information ................................................................................ 14
3.4
ATE
Enable command echo .............................................................................................................. 15
3.5
AT&V Display current configuration ................................................................................................ 16
3.6
ATV Set result code format mode ..................................................................................................... 16
3.7
AT&F
3.8
ATQ
Set Result Code Presentation Mode ......................................................................................... 18
3.9
ATX
Set CONNECT Result Code Format ........................................................................................ 19
3.10
AT\V Set CONNECT Result Code Format About Protocol .............................................................. 19
3.11
AT&E
3.12
AT&W Save the user setting to ME .................................................................................................. 21
3.13
ATZ
3.14
AT+CGMI
Request manufacturer identification ............................................................................... 22
3.15
AT+CGMM
Request model identification ........................................................................................ 23
3.16
AT+CGMR
Request revision identification ...................................................................................... 24
3.17
AT+CGSN
Request product serial number identification ................................................................. 24
3.18
AT+CSCS
Select TE character set .................................................................................................... 25
3.19
AT+CIMI
Request international mobile subscriber identity ............................................................. 26
3.20
AT+CIMIM
3.21
AT+GCAP Request overall capabilities ............................................................................................ 27
C
on
f
id
e
3.1
Set all current parameters to manufacturer defaults ............................................................... 17
Set CONNECT Result Code Format About Speed ................................................................ 20
M
C
om
Restore the user setting from ME.............................................................................................. 22
4
Request another international mobile subscriber identity ............................................. 27
AT Commands for Status Control .................................................................................................. 29
AT+CFUN
Set phone functionality ................................................................................................... 29
4.2
AT+CPIN
Enter PIN.......................................................................................................................... 30
4.3
AT+CICCID
4.4
AT+CSIM
Generic SIM access ......................................................................................................... 32
4.5
AT+CRSM
Restricted SIM access .................................................................................................... 33
4.6
AT+SPIC Times remain to input SIM PIN/PUK ............................................................................... 37
4.7
AT+CSPN
SI
4.1
Read ICCID from SIM card......................................................................................... 31
Get service provider name from SIM .............................................................................. 38
SIM7906_SIM7912 Series_AT Command Manual_V1.01
3
2019-11-21
Smart Machine Smart Decision
4.8
AT+CSQ
4.9
AT+AUTOCSQ
4.10
AT+CSQDELTA Set RSSI delta change threshold ............................................................................ 41
4.11
AT+CPOF
4.12
AT+CRESET
4.13
AT+CACM
Accumulated call meter ................................................................................................. 43
4.14
AT+CAMM
Accumulated call meter maximum ............................................................................... 44
4.15
AT+CPUC
Price per unit and currency table..................................................................................... 45
4.16
AT+CCLK
Real time clock management .......................................................................................... 46
4.17
AT+CMEE
Report mobile equipment error ...................................................................................... 47
4.18
AT+CPAS
Phone activity status ........................................................................................................ 48
4.19
AT+SIMEI
Set IMEI for the module ................................................................................................. 49
4.20
AT+CUSBPIDSWITCH
Set CSQ report........................................................................................................ 40
lF
ile
Power down the module .................................................................................................. 42
ia
Reset the module ........................................................................................................ 42
nt
Change module’s PID................................................................................ 50
AT Commands for Network ........................................................................................................... 52
AT+CREG
Network registration ....................................................................................................... 52
5.2
AT+COPS
Operator selection ........................................................................................................... 53
5.3
AT+CLCK
Facility lock .................................................................................................................... 55
5.4
AT+CPWD
Change password ........................................................................................................... 57
5.5
AT+CCUG
Closed user group ........................................................................................................... 59
5.6
AT+CUSD
Unstructured supplementary service data ....................................................................... 60
5.7
AT+CAOC
5.8
AT+CSSN
5.9
AT+CPOL Preferred operator list ...................................................................................................... 64
5.10
AT+COPN
5.11
AT+CNMP Preferred mode selection ................................................................................................ 67
5.12
AT+CNBP Preferred band selection .................................................................................................. 68
5.13
AT+CNAOP Acquisitions order preference ...................................................................................... 71
5.14
AT+CPSI
id
e
5.1
C
on
f
5
Query signal quality .......................................................................................................... 39
Advice of charge ............................................................................................................ 61
Supplementary service notifications................................................................................ 62
Read operator names ...................................................................................................... 66
C
om
Inquiring UE system information ..................................................................................... 72
5.15
AT+CNSMOD
5.16
AT+CEREG
5.17
AT+CTZU
Automatic time and time zone update............................................................................. 77
5.18
AT+CTZR
Time and time zone reporting ......................................................................................... 78
6
Show network system mode ..................................................................................... 74
EPS network registration status .................................................................................... 75
AT Commands for SMS................................................................................................................. 81
AT+CSMS
Select message service.................................................................................................... 81
6.2
AT+CPMS
Preferred message storage .............................................................................................. 82
6.3
AT+CMGF
Select SMS message format ........................................................................................... 84
6.4
AT+CSCA SMS service centre address ............................................................................................. 85
6.5
AT+CSCB
6.6
AT+CSMP Set text mode parameters ................................................................................................ 87
6.7
AT+CSDH
6.8
AT+CNMA New message acknowledgement to ME/TA .................................................................. 89
6.9
AT+CNMI
6.10
AT+CGSMS
SI
M
6.1
Select cell broadcast message indication ........................................................................ 86
Show text mode parameters ............................................................................................ 88
New message indications to TE ...................................................................................... 90
Select service for MO SMS messages ......................................................................... 92
SIM7906_SIM7912 Series_AT Command Manual_V1.01
4
2019-11-21
Smart Machine Smart Decision
AT+CMGL List SMS messages from preferred storeDescription ..................................................... 93
6.12
AT+CMGR
Read message ................................................................................................................ 97
6.13
AT+CMGS
Send message ............................................................................................................... 101
6.14
AT+CMSS
Send message from storage .......................................................................................... 102
6.15
AT+CMGW Write message to memory .......................................................................................... 103
6.16
AT+CMGD
6.17
AT+CMGMT
6.18
AT+CMVP Set message valid period .............................................................................................. 106
6.19
AT+CMGRD
Read and delete message .......................................................................................... 107
6.20
AT+CMGSEX
Send message .......................................................................................................... 109
6.21
AT+CMSSEX
Send multi messages from storage ...........................................................................110
Delete message ............................................................................................................ 105
Change message status ............................................................................................. 106
ia
7
lF
ile
6.11
AT Commands for Phonebook ......................................................................................................112
AT+CPBS
Select phonebook memory storage .................................................................................112
7.2
AT+CPBR
Read phonebook entries .................................................................................................113
7.3
AT+CPBF
Find phonebook entries ..................................................................................................115
7.4
AT+CPBW Write phonebook entry ..................................................................................................116
7.5
AT+CNUM
id
e
8
nt
7.1
Subscriber number........................................................................................................117
AT Commands for GPRS..............................................................................................................119
AT+CGREG
GPRS network registration status ...............................................................................119
8.2
AT+CGATT Packet domain attach or detach .................................................................................. 120
8.3
AT+CGACT
8.4
AT+CGDCONT
Define PDP context .............................................................................................. 122
8.5
AT+CGDSCONT
Define Secondary PDP Context ......................................................................... 124
8.6
AT+CGTFT Traffic Flow Template ................................................................................................ 126
8.7
AT+CGQREQ
8.8
AT+CGEQREQ
8.9
AT+CGQMIN
8.10
AT+CGEQMIN
C
on
f
8.1
PDP context activate or deactivate ............................................................................. 121
Quality of service profile (requested) ..................................................................... 129
3G quality of service profile (requested) .............................................................. 132
Quality of service profile (minimum acceptable) .................................................... 137
C
om
3G quality of service profile (minimum acceptable) ............................................ 139
8.11
AT+CGDATA Enter data state......................................................................................................... 144
8.12
AT+CGPADDR
Show PDP address ................................................................................................ 145
8.13
AT+CGCLASS
GPRS mobile station class .................................................................................. 147
8.14
AT+CGEREP GPRS event reporting .............................................................................................. 148
8.15
AT+CGAUTH
9
Set type of authentication for PDP-IP connections of GPRS .................................. 150
AT Commands for SIM Application Toolkit................................................................................ 152
AT+STIN
SAT Indication ................................................................................................................ 152
9.2
AT+STGI
Get SAT information ...................................................................................................... 153
9.3
AT+STGR
SAT respond .................................................................................................................. 156
9.4
AT+STK
9.5
AT+STKFMT Set STK pdu format ................................................................................................. 158
9.6
AT+STENV Original STK PDU Envelope Command .................................................................... 159
9.7
AT+STSM
SI
M
9.1
10
10.1
STK switch ...................................................................................................................... 157
Get STK Setup Menu List with PDU Mode ................................................................. 160
AT Commands for File Transmission ...................................................................................... 161
AT+CFTRANRX
Transfer a file to EFS ......................................................................................... 161
SIM7906_SIM7912 Series_AT Command Manual_V1.01
5
2019-11-21
Smart Machine Smart Decision
10.2
11
AT+CFTRANTX
Transfer a file from EFS to host ......................................................................... 162
AT Commands for Open/Close Network ................................................................................. 164
AT+CNETSTART
11.2
AT+CNETSTOP Close network ...................................................................................................... 165
11.3
AT+CNETIPADDR
11.4
12
Open network .................................................................................................... 164
lF
ile
11.1
Inquire PDP address ....................................................................................... 166
Unsolicited Open/Close network command <err> Codes .................................................................. 166
AT Commands for GPS ........................................................................................................... 168
12.1
AT+CGPS
Start/Stop GPS session .................................................................................................. 168
12.2
AT+CGPSINFO
Get GPS fixed position information ..................................................................... 169
12.3
AT+CGPSCOLD
Cold start GPS .................................................................................................... 171
12.4
AT+CGPSHOT
12.5
AT+CGPSURL Set AGPS default server URL ............................................................................... 172
12.6
AT+CGPSSSL Set AGPS transport security ................................................................................... 173
12.7
AT+CGPSAUTO
12.8
AT+CGPSNMEA Configure NMEA sentence type ........................................................................ 174
12.9
AT+CGPSNEMARATE
nt
ia
Hot start GPS ........................................................................................................ 171
Start GPS automatic ........................................................................................... 173
id
e
Set NMEA output rate ........................................................................... 175
12.10 AT+CGPSMD
Configure AGPS MO method ................................................................................. 176
12.11 AT+CGPSFTM
Start GPS test mode .............................................................................................. 177
12.12 AT+CGPSDEL Delete the GPS information ................................................................................... 178
Enable/Disable GPS XTRA function ....................................................................... 179
C
on
f
12.13 AT+CGPSXE
12.14 AT+CGPSXD
Download XTRA assistant file ................................................................................ 180
12.15 AT+CGPSXDAUTO
Download XTRA assistant file automatically............................................... 181
12.16 AT+CGPSINFOCFG
Report GPS NMEA-0183 sentence .............................................................. 181
12.17 AT+CGPSPMD
Configure positioning mode ................................................................................. 183
12.18 AT+CGPSMSB
Configure based mode switch to standalone ......................................................... 184
12.19 AT+CGPSHOR
Configure positioning desired accuracy ................................................................ 185
12.20 AT+CGPSNOTIFY LCS respond positioning request .................................................................... 186
Get GNSS fixed position information ............................................................... 187
C
om
12.21 AT+CGNSSINFO
12.22 AT+CGNSSMODE
Configure GNSS support mode ...................................................................... 189
12.23 Unsolicited XTRA download Codes .................................................................................................. 190
12.24 AT+CLBS
Base station location...................................................................................................... 190
12.25 AT+CLBSCFG
Base station location configure .............................................................................. 193
12.26 AT+CGTP Get the IZAT location .................................................................................................... 194
13
M
13.1
AT Commands for Call Control ............................................................................................... 198
AT+CVHU
Voice hang up control .................................................................................................. 198
AT+CHUP Hang up call .................................................................................................................. 199
13.3
AT+CBST
13.4
AT+CRLP Radio link protocol ........................................................................................................ 201
13.5
AT+CR
13.6
AT+CRC
13.7
AT+CLCC
List current calls............................................................................................................ 205
13.8
AT+CEER
Extended error report .................................................................................................... 207
13.9
AT+CCWA Call waiting .................................................................................................................. 208
SI
13.2
Select bearer service type .............................................................................................. 199
Service reporting control.................................................................................................... 202
Cellular result codes ........................................................................................................ 204
SIM7906_SIM7912 Series_AT Command Manual_V1.01
6
2019-11-21
Smart Machine Smart Decision
13.10 AT+CHLD
Call related supplementary services ............................................................................. 209
13.11 AT+CCFC
Call forwarding number and conditions .........................................................................211
13.12 AT+CLIP Calling line identification presentation ........................................................................... 212
Calling line identification restriction .............................................................................. 214
lF
ile
13.13 AT+CLIR
13.14 AT+COLP Connected line identification presentation .................................................................... 215
13.15 AT+VTS
DTMF and tone generation .............................................................................................. 217
13.16 AT+VTD
Tone duration .................................................................................................................. 218
13.17 AT+CSTA Select type of address .................................................................................................... 219
13.18 AT+CMOD
Call mode .................................................................................................................... 220
13.19 AT+CSDVC
Switch voice channel device ...................................................................................... 221
ia
13.20 AT+CLVL Loudspeaker volume level ............................................................................................. 222
13.21 AT+SIDET
AT Command for Hardware..................................................................................................... 224
nt
14
Set sidetone .................................................................................................................. 223
14.1
AT+CBC
14.2
AT+CVALARM
14.3
AT+CPMVT
14.4
AT+CPMUTEMP Read the temperature of the module .................................................................. 226
14.5
AT+CADC0
Read ADC0 value ....................................................................................................... 227
14.6
AT+CADC1
Read ADC1 value ....................................................................................................... 228
14.7
AT+CADC2
Read ADC2 value ....................................................................................................... 229
14.8
AT+CVAUS Set state of the pin named VREG_L14_SDC ................................................................ 230
14.9
AT+CVAUV Set microvolt of the pin named VREG_L14_SDC ....................................................... 231
Low and high voltage Alarm................................................................................ 224
id
e
Low and high voltage Power Off ............................................................................... 225
C
on
f
15
Read the voltage value of the power supply .................................................................... 224
Appendixes .............................................................................................................................. 232
Verbose code and numeric code ......................................................................................................... 232
15.2
Response string of AT+CEER ............................................................................................................ 232
15.3
Summary of CME ERROR codes ...................................................................................................... 236
15.4
Summary of CMS ERROR codes ...................................................................................................... 239
SI
M
C
om
15.1
SIM7906_SIM7912 Series_AT Command Manual_V1.01
7
2019-11-21
1.1
Introduction
Scope
The present document describes the AT Command Set for the SIMCom Module:
SIM7906/SIM7912 series
lF
ile
1
nt
ia
More information about the SIMCom Module which includes the Software Version information can be
retrieved by the command ATI. In this document, a short description, the syntax, the possible setting values
and responses, and some examples of AT commands are presented.
id
e
Prior to using the Module, please read this document and the Version History to know the difference from
the previous document.
1.2
References
C
on
f
In order to implement communication successfully between Customer Application and the Module, it is
recommended to use the AT commands in this document, but not to use some commands which are not
included in this document.
The present document is based on the following standards:
C
om
[1] 3GPP TS 27.005: Use of Data Terminal Equipment – Data Circuit terminating Equipment (DTE –
DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS).
[2] 3GPP TS 27.007: AT command set for User Equipment (UE).
[3] WAP-224-WTP-20010710-a
[4] WAP-230-WSP-20010705-a
[5] WAP-209-MMSEncapsulation-20010601-a
Terms and abbreviations
SI
M
1.3
For the purposes of the present document, the following abbreviations apply:
AT
ATtention; the two-character abbreviation is used to start a command line to be sent
from TE/DTE to TA/DCE
DCE
Data Communication Equipment; Data Circuit terminating Equipment
DCS
Digital Cellular Network
DTE
Data Terminal Equipment
DTMF
Dual Tone Multi–Frequency
EGPRS
Enhanced General Packet Radio Service
ia
id
e
nt
General–Purpose Input/Output
General Packet Radio Service
Global System for Mobile communications
High Speed Downlink Packet Access
High Speed Uplink Packet Access
Inter–Integrated Circuit
International Mobile station Equipment Identity
International Mobile Subscriber Identity
Mobile Equipment
Mobile–Originated
Mobile Station
Mobile–Terminated; Mobile Termination
Personal Communication System
Protocol Data Unit
Personal Identification Number
Personal Unlock Key
Subscriber Identity Module
Short Message Service
Short Message Service – Service Center
Terminal Adaptor; e.g. a data card (equal to DCE)
Terminal Equipment; e.g. a computer (equal to DTE)
User Equipment
Universal Mobile Telecommunications System
Universal Subscriber Identity Module
Wideband Code Division Multiple Access
File Transfer Protocol
Hyper Text Transfer Protocol
Real Time Clock
Unsolicited Result Code
C
on
f
GPIO
GPRS
GSM
HSDPA
HSUPA
I2C
IMEI
IMSI
ME
MO
MS
MT
PCS
PDU
PIN
PUK
SIM
SMS
SMS–SC
TA
TE
UE
UMTS
USIM
WCDMA
FTP
HTTP
RTC
URC
C
om
lF
ile
Smart Machine Smart Decision
1.4
Definitions and conventions
1. For the purposes of the present document, the following syntactical definitions apply:
Carriage return character.
<LF>
Linefeed character.
<…>
Name enclosed in angle brackets is a syntactical element. Brackets themselves do not
appear in the command line.
[…]
Optional subparameter of AT command or an optional part of TA information response
is enclosed in square brackets. Brackets themselves do not appear in the command line.
If subparameter is not given, its value equals to its previous value or the recommended
default value.
Underlined defined subparameter value is the recommended default setting or factory
SI
M
<CR>
underline
SIM7906_SIM7912 Series_AT Command Manual_V1.01
9
2019-11-21
Smart Machine Smart Decision
setting.
2. Document conventions:
Display the examples of AT commands with Italic format.
Not display blank-line between command line and responses or inside the responses.
Generally, the characters <CR> and <LF> are intentionally omitted throughout this document.
If command response is ERROR, not list the ERROR response inside command syntax.
lF
ile
♦
♦
♦
♦
NOTE: AT commands and responses in figures may be not following above conventions.
SIM PIN
–
ia
3. Special marks for commands or parameters:
Is the command PIN protected?
YES –
AT command can be used only when SIM PIN is READY.
– AT command can be used when SIM card is absent or SIM PIN validation is
pending.
References – Where is the derivation of command?
nt
NO
– 3GPP Technical Specification 127 007.
V.25ter
– ITU–T Recommendation V.25ter.
Vendor
– This command is supported by SIMCom.
SI
M
C
om
C
on
f
id
e
3GPP TS 27.007
SIM7906_SIM7912 Series_AT Command Manual_V1.01
10
2019-11-21
Smart Machine Smart Decision
2.1
AT Interface Synopsis
lF
ile
2
Interface settings
Between Customer Application and the Module, standardized RS–232 interface is used for the
communication, and default values for the interface settings as following:
AT command syntax
nt
2.2
ia
115200bps, 8 bit data, no parity, 1 bit stop, no data stream control.
id
e
The prefix “AT” or “at” (no case sensitive) must be included at the beginning of each command line
(except A/ and +++), and the character <CR> is used to finish a command line so as to issue the command
line to the Module. It is recommended that a command line only includes a command.
C
on
f
When Customer Application issues a series of AT commands on separate command lines, leave a pause
between the preceding and the following command until information responses or result codes are retrieved
by Customer Application, for example, “OK” is appeared. This advice avoids too many AT commands are
issued at a time without waiting for a response for each command.
In the present document, AT commands are divided into three categories: Basic Command, S Parameter
Command, and Extended Command.
1. Basic Command
C
om
The format of Basic Command is “AT<x><n>” or “AT&<x><n>”, “<x>” is the command name, and “<n>”
is/are the parameter(s) for the basic command, and optional. An example of Basic Command is “ATE<n>”,
which informs the TA/DCE whether received characters should be echoed back to the TE/DTE according to
the value of “<n>”; “<n>” is optional and a default value will be used if omitted.
2. S Parameter Command
M
The format of S Parameter Command is “ATS<n>=<m>”, “<n>” is the index of the S–register to set, and
“<m>” is the value to assign to it. “<m>” is optional; in this case, the format is “ATS<n>”, and then a
default value is assigned.
SI
3. Extended Command
The Extended Command has several formats, as following table list:
Table 2-1: Types of Extended Command
SIM7906_SIM7912 Series_AT Command Manual_V1.01
11
2019-11-21
Smart Machine Smart Decision
Syntax
Comments
Test Command
AT+<NAME>=?
Test the existence of the command; give some
information about the command subparameters.
Read Command
AT+<NAME>?
Check the current values of subparameters.
Write Command
AT+<NAME>=<…>
Set user-definable subparameter values.
Execution Command
AT+<NAME>
Read non-variable subparameters determined by
internal processes.
lF
ile
Command Type
Information responses
nt
2.3
ia
NOTE: The character “+” between the prefix “AT” and command name may be replaced by other
character. For example, using “#” or “$”instead of “+”.
id
e
If the commands included in the command line are supported by the Module and the subparameters are
correct if presented, some information responses will be retrieved by from the Module. Otherwise, the
Module will report “ERROR” or “+CME ERROR” or “+CMS ERROR” to Customer Application.
SI
M
C
om
C
on
f
Information responses start and end with <CR><LF>, i.e. the format of information responses is
“<CR><LF><response><CR><LF>”. Inside information responses, there may be one or more <CR><LF>.
Throughout this document, only the responses are presented, and <CR><LF> are intentionally omitted.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
12
2019-11-21
Smart Machine Smart Decision
3.1
AT Commands According V.25TER
A/
lF
ile
3
Repeat last command
Description
nt
NO
References
V.25ter
Syntax
Examples
Responses
The response the last AT command return
C
on
f
Execution Command
A/
id
e
SIM PIN
ia
This command is used for implement previous AT command repeatedly (except A/), and the return
value depends on the last AT command. If A/ is issued to the Module firstly after power on, the
response “OK” is only returned.
C
om
AT+GCAP
+GCAP:+CWCDMA,+FCLASS,+DS
OK
A/
+GCAP:+CWCDMA,+FCLASS,+DS
OK
3.2 ATH
Disconnect existing call
Description
SI
M
This command is used to disconnect existing call. Before using ATH command to hang up a voice
call, it must set AT+CVHU=0. Otherwise, ATH command will be ignored and “OK” response is
given only.
This command is also used to disconnect PS data call, and in this case it doesn’t depend on the
value of AT+CVHU.
SIM PIN
NO
References
V.25ter
Syntax
SIM7906_SIM7912 Series_AT Command Manual_V1.01
13
2019-11-21
Smart Machine Smart Decision
Responses
If AT+CVHU=0:
VOICE CALL: END: <time>
OK
lF
ile
Execution Command
ATH
OK
<time>
Voice call connection time:
Format – HHMMSS (HH: hour, MM: minute, SS: second)
nt
Examples
id
e
AT+CVHU=0
OK
ATH
VOICE CALL:END:000017
OK
ATI Display product identification information
C
on
f
3.3
ia
Defined values
Description
This command is used to request the product information, which consists of manufacturer
identification, model identification, revision identification, International Mobile station Equipment
Identity (IMEI) and overall capabilities of the product.
References
C
om
SIM PIN
NO
V.25ter
Syntax
SI
M
Execution Command
ATI
Responses
Manufacturer: <manufacturer>
Model: <model>
Revision: <revision>
IMEI: <sn>
+GCAP: list of <name>s
OK
Defined values
SIM7906_SIM7912 Series_AT Command Manual_V1.01
14
2019-11-21
Smart Machine Smart Decision
Examples
C
on
f
ATI
Manufacturer: SIMCOM INCORPORATED
Model: SIMCOM_SIM7906
Revision: SIM7600C _V3.0
IMEI: 351602000330570
+GCAP: +CGSM,+FCLASS,+DS
OK
ATE
Enable command echo
C
om
3.4
id
e
nt
ia
lF
ile
<manufacturer>
The identification of manufacturer.
<model>
The identification of model.
<revision>
The revision identification of firmware.
<sn>
Serial number identification, which consists of a single line containing IMEI (International Mobile
station Equipment Identity) number.
<name>
List of additional capabilities:
+FCLASS
FAX function is supported
+DS
Data compression is supported
+ES
Synchronous data mode is supported.
+MS
Mobile Specific command set
Description
This command sets whether or not the TA echoes characters.
SIM PIN
V.25ter
M
NO
References
SI
Syntax
Execution Command
ATE[<value>]
Responses
OK
ERROR
Defined values
SIM7906_SIM7912 Series_AT Command Manual_V1.01
15
2019-11-21
Smart Machine Smart Decision
Echo mode off
Echo mode on
lF
ile
<value>
0 –
1 –
Examples
ATE1
OK
AT&V Display current configuration
ia
3.5
Description
YES
References
V.25ter
Syntax
Responses
<TEXT>
C
on
f
Execution Command
AT&V
id
e
SIM PIN
nt
This command returns some of the base configuration parameters settings.
OK
ERROR
Defined values
C
om
<TEXT>
All relative configuration information.
Examples
SI
M
AT&V
&C: 0; &D: 2; &F: 0; E: 1; L: 0; M: 0; Q: 0; V: 1; X: 0; Z: 0; S0: 0;
S3: 13; S4: 10; S5: 8; S6: 2; S7: 50; S8: 2; S9: 6; S10: 14; S11: 95;
+FCLASS: 0; +ICF: 3,3; +IFC: 2,2; +IPR: 115200; +DR: 0; +DS: 0,0,2048,6;
+WS46: 12; +CBST: 0,0,1;
……
OK
3.6
ATV Set result code format mode
Description
This parameter setting determines the contents of the header and trailer transmitted with result
SIM7906_SIM7912 Series_AT Command Manual_V1.01
16
2019-11-21
Smart Machine Smart Decision
codes and information responses.
NOTE: In case of using This command without parameter <value> will be set to 0.
No
References
V.25ter
lF
ile
SIM PIN
Syntax
ia
Responses
If <value> =0
0
If <value> =1
OK
nt
Write Command
ATV[<value>]
Defined values
C
on
f
id
e
<value>
0 Information response: <text><CR><LF>
Short result code format: <numeric code><CR>
1 Information response: <CR><LF><text><CR><LF>
Long result code format: <CR><LF><verbose code><CR><LF>
Examples
ATV1
OK
AT&F Set all current parameters to manufacturer defaults
C
om
3.7
Description
This command is used to set all current parameters to the manufacturer defined profile.
NOTE:List of parameters reset to manufacturer default can be found in defined values, factory
default settings restorable with AT&F[<value>].
Every ongoing or incoming call will be terminated.
SI
M
SIM PIN
NO
References
V.250
Syntax
Execution Command
AT&F[<value>]
Responses
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
17
2019-11-21
Smart Machine Smart Decision
Defined values
<value>
lF
ile
0 — Set some temporary TA parameters to manufacturer defaults. The setting after power on or reset is
same as value 0.
default values
TA parameters
VALUE
0
AT+CNMP
2
AT+CNAOP ①
7,9,4,2,5,3,11
AT+CTZU
0
ia
AT+CATR
nt
Examples
3.8
ATQ
id
e
AT&F
OK
Set Result Code Presentation Mode
C
on
f
Description
Specify whether the TA transmits any result code to the TE or not. Text information transmitted in
response is not affected by this setting
SIM PIN
YES
References
3GPP TS 27.005
Syntax
C
om
Write Command
ATQ<n>
SI
M
Execution Command
ATQ
Responses
If <n>=0:
OK
If <n>=1:
No Responses
Responses
Set default value:0
OK
No Responses
Defined values
<n>
0 – DCE transmits result code
1 – DCE not transmits result code
SIM7906_SIM7912 Series_AT Command Manual_V1.01
18
2019-11-21
Smart Machine Smart Decision
Examples
3.9
lF
ile
ATQ0
OK
ATX Set CONNECT Result Code Format
Description
YES
References
3GPP TS 27.005
nt
SIM PIN
ia
This parameter setting determines whether the TA transmits unsolicited result codes or not. The
unsolicited result codes are
<CONNECT><SPEED><COMMUNICATION PROTOCOL>[<TEXT>]
Write Command
ATX<VALUE>
Responses
OK
C
on
f
ERROR
id
e
Syntax
Execution Command
ATX
Responses
Set default value:1
OK
ERROR
Defined values
C
om
<value>
0 – CONNECT result code returned
1,2,3,4 – May be transmits extern result codes according to AT&E and AT\V settings. Refer to
AT&E.
Examples
M
ATX1
OK
SI
3.10
AT\V Set CONNECT Result Code Format About Protocol
Description
This parameter setting determines whether report the communication protocol. If PS call, it also
determines wether report APN, uplink rate, downlink rate.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
19
2019-11-21
Smart Machine Smart Decision
SIM PIN
YES
References
3GPP TS 27.005
Write Command
AT\V<value>
lF
ile
Syntax
Responses
OK
ERROR
Responses
Set default value: 0
OK
ia
Execution Command
AT\V
nt
ERROR
Defined values
C
on
f
id
e
<value>
0 – Don’t report
1 – Report communication protocol. And report APN, uplink rate, downlink rate if PS call.
Refer
to
AT&E.
The
maybe
communication
protocol
report
include
“NONE”,”PPPoverUD”,”AV32K”,”AV64K”,”PACKET”. And APN in string format while
uplink rate and downlink rate in integer format with kb unit.
Examples
AT\V0
OK
AT&E
Set CONNECT Result Code Format About Speed
C
om
3.11
Description
This parameter setting determines to report Serial connection rate or Wireless connection speed. It
is valid only ATX above 0.
SIM PIN
M
YES
References
3GPP TS 27.005
SI
Syntax
Write Command
Responses
AT&E<value>
OK
ERROR
Execution Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
20
2019-11-21
Smart Machine Smart Decision
Set default value: 1
OK
lF
ile
AT&E
Defined values
<value>
0 – Wireless connection speed in integer format.
1 – Serial connection rate in integer format. Such as: “115200”
ia
Examples
AT&W Save the user setting to ME
id
e
3.12
nt
AT&E0
OK
Description
This command will save the user settings to ME which set by ATE, ATQ, ATV, ATX, AT&C AT&D,
AT&S, AT\V, AT+IFC and ATS0.
YES
References
C
on
f
SIM PIN
3GPP TS 27.005
Syntax
Write Command
AT&W<value>
Responses
OK
C
om
ERROR
Execution Command
AT&W
Responses
Set default value: 0
OK
ERROR
M
Defined values
SI
<value>
0 – Save
Examples
AT&W0
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
21
2019-11-21
Smart Machine Smart Decision
3.13
ATZ Restore the user setting from ME
lF
ile
Description
This command will restore the user setting from ME which set by ATE, ATQ, ATV, ATX, AT&C
AT&D, AT&S, AT\Q, AT\V, and ATS0.
SIM PIN
YES
References
3GPP TS 27.005
Responses
OK
ERROR
Responses
Set default value: 0
OK
Defined values
<value>
0 – Restore
Examples
C
om
ATZ0
OK
C
on
f
ERROR
id
e
Execution Command
ATZ
nt
Write Command
ATZ<value>
ia
Syntax
3.14
AT+CGMI Request manufacturer identification
Description
M
This command is used to request the manufacturer identification text, which is intended to permit
the user of the Module to identify the manufacturer.
SIM PIN
3GPP TS 27.007
SI
NO
References
Syntax
Test Command
AT+CGMI=?
Responses
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
22
2019-11-21
Smart Machine Smart Decision
Responses
<manufacturer>
OK
lF
ile
Execution Command
AT+CGMI
Defined values
<manufacturer>
The identification of manufacturer.
ia
Examples
AT+CGMM Request model identification
id
e
3.15
nt
AT+CGMI
SIMCOM INCORPORATED
OK
Description
SIM PIN
NO
C
on
f
This command is used to requests model identification text, which is intended to permit the user of
the Module to identify the specific model.
References
3GPP TS 27.007
Syntax
Test Command
C
om
AT+CGMM=?
Responses
OK
Execution Command
Responses
AT+CGMM
<model>
OK
Defined values
M
<model>
The identification of model.
SI
Examples
AT+CGMM
SIMCOM_SIM7600C
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
23
2019-11-21
Smart Machine Smart Decision
3.16
AT+CGMR Request revision identification
lF
ile
Description
This command is used to request product firmware revision identification text, which is intended to
permit the user of the Module to identify the version.
SIM PIN References
NO
3GPP TS 27.007
Responses
AT+CGMR=?
OK
Execution Command
Responses
AT+CGMR
+CGMR: <revision>
OK
Defined values
C
on
f
<revision>
The revision identification of firmware.
id
e
Test Command
nt
ia
Syntax
Examples
C
om
AT+CGMR
+CGMR: LE11B01SIM7906
OK
3.17
AT+CGSN Request product serial number identification
Description
This command requests product serial number identification text, which is intended to permit the
user of the Module to identify the individual ME to which it is connected to.
SI
M
SIM PIN
NO
References
3GPP TS 27.007
Syntax
Test Command
Responses
AT+CGSN=?
OK
Execution Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
24
2019-11-21
Smart Machine Smart Decision
<sn>
OK
lF
ile
AT+CGSN
Defined values
<sn>
Serial number identification, which consists of a single line containing the IMEI (International
Mobile station Equipment Identity) number of the MT.
ia
Examples
AT+CSCS
id
e
3.18
nt
AT+CGSN
351602000330570
OK
Select TE character set
Description
SIM PIN
YES
C
on
f
Write command informs TA which character set <chest> is used by the TE. TA is then able to
convert character strings correctly between TE and MT character sets.
Read command shows current setting and test command displays conversion schemes implemented
in the TA.
References
3GPP TS 27.007
C
om
Syntax
Test Command
AT+CSCS=?
M
Read Command
AT+CSCS?
SI
Write Command
AT+CSCS=<chset>
Execution Command
AT+CSCS
Responses
+CSCS: (list of supported <chset>s)
OK
Responses
+CSCS: <chset>
OK
Responses
OK
ERROR
Responses
Set subparameters as default value:
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
25
2019-11-21
Smart Machine Smart Decision
Defined values
lF
ile
<chest>
Character set, the definition as following:
“IRA”
International reference alphabet.
“UCS2” 16-bit universal multiple-octet coded character set; UCS2 character strings are
converted to hexadecimal numbers from 0000 to FFFF.
Examples
nt
AT+CIMI Request international mobile subscriber identity
id
e
3.19
ia
AT+CSCS=”IRA”
OK
AT+CSCS?
+CSCS: ”IRA”
OK
Description
SIM PIN
YES
C
on
f
Execution command causes the TA to return <IMSI>, which is intended to permit the TE to identify
the individual SIM card which is attached to MT.
NOTE: If USIM card contains two apps, like China Telecom 4G card, one RUIM/CSIM app, and
another USIM app; so there are two IMSI in it; AT+CIMI will return the RUIM/CSIM IMSI;
AT+CIMIM will return the USIM IMSI;
References
3GPP TS 27.007
C
om
Syntax
Responses
OK
Execution Command
AT+CIMI
ERROR
Responses
<IMSI>
OK
SI
M
Test Command
AT+CIMI=?
ERROR
Defined values
<IMSI>
International Mobile Subscriber Identity (string, without double quotes).
Examples
SIM7906_SIM7912 Series_AT Command Manual_V1.01
26
2019-11-21
Smart Machine Smart Decision
3.20
lF
ile
AT+CIMI
460010222028133
OK
AT+CIMIM Request another international mobile subscriber identity
Description
nt
YES
References
3GPP TS 27.007
Syntax
Responses
AT+CIMIM=?
OK
C
on
f
Test Command
id
e
SIM PIN
ia
Execution command causes the TA to return <IMSI>, which is intended to permit the TE to identify
the individual SIM card which is attached to MT.
NOTE: If USIM card contains two apps, like China Telecom 4G card, one RUIM/CSIM app, and
another USIM app; so there are two IMSI in it; AT+CIMIM will return the USIM IMSI; AT+CIMI
will return the RUIM/CSIM IMSI;
ERROR
Execution Command
Responses
AT+CIMIM
<IMSI>
OK
ERROR
C
om
Defined values
<IMSI>
International Mobile Subscriber Identity (string, without double quotes).
Examples
M
AT+CIMIM
460110222028133
OK
SI
3.21
AT+GCAP Request overall capabilities
Description
Execution command causes the TA reports a list of additional capabilities.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
27
2019-11-21
Smart Machine Smart Decision
SIM PIN
YES
References
V.25ter
Test Command
AT+GCAP=?
lF
ile
Syntax
Responses
OK
ERROR
Responses
+GCAP: (list of <name>s)
OK
ia
Execution Command
AT+GCAP
nt
ERROR
id
e
Defined values
Examples
C
on
f
<name>
List of additional capabilities.
+CGSM
GSM function is supported
+FCLASS
FAX function is supported
+DS
Data compression is supported
+ES
Synchronous data mode is supported.
+MS
Mobile Specific command set
SI
M
C
om
AT+GCAP
+GCAP:+CGSM,+FCLASS,+DS
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
28
2019-11-21
Smart Machine Smart Decision
4.1
AT Commands for Status Control
lF
ile
4
AT+CFUN Set phone functionality
Description
NO
References
id
e
SIM PIN
nt
ia
This command is used to select the level of functionality <fun> in the ME. Level "full
functionality" is where the highest level of power is drawn. "Minimum functionality" is where
minimum power is drawn. Level of functionality between these may also be specified by
manufacturers. When supported by manufacturers, ME resetting with <rst> parameter may be
utilized.
NOTE: AT+CFUN=6 must be used after setting AT+CFUN=7. If module in offline mode, must
execute AT+CFUN=6 or restart module to online mode.
3GPP TS 27.007
Test Command
AT+CFUN=?
C
on
f
Syntax
Responses
+CFUN: (list of supported <fun>s), (list of supported <rst>s)
OK
ERROR
+CME ERROR: <err>
C
om
Read Command
AT+CFUN?
SI
M
Write Command
AT+CFUN=<fun>[,<rst>]
Responses
+CFUN: <fun>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<fun>
0
1
4
– minimum functionality
– full functionality, online mode
– disable phone both transmit and receive RF circuits
SIM7906_SIM7912 Series_AT Command Manual_V1.01
29
2019-11-21
Smart Machine Smart Decision
lF
ile
5 – Factory Test Mode
6 – Reset
7 – Offline Mode
<rst>
0 – do not reset the ME before setting it to <fun> power level
1 – reset the ME before setting it to <fun> power level. This value only takes effect when
<fun> equals 1.
Examples
nt
AT+CPIN Enter PIN
Description
id
e
4.2
ia
AT+CFUN?
+CFUN: 1
OK
AT+CFUN=0
OK
SIM PIN
References
3GPP TS 27.007
C
om
NO
C
on
f
This command is used to send the ME a password which is necessary before it can be operated
(SIM PIN, SIM PUK, PH-SIM PIN, etc.). If the PIN is to be entered twice, the TA shall
automatically repeat the PIN. If no PIN request is pending, no action is taken towards MT and an
error message, +CME ERROR, is returned to TE.
If the PIN required is SIM PUK or SIM PUK2, the second pin is required. This second pin,
<newpin>, is used to replace the old pin in the SIM.
Syntax
Responses
OK
Read Command
AT+CPIN?
Responses
+CPIN: <code>
OK
SI
M
Test Command
AT+CPIN=?
ERROR
+CME ERROR: <err>
Write Command
AT+CPIN=<pin>[,<newpin>
]
Responses
OK
ERROR
+CME ERROR: <err>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
30
2019-11-21
Smart Machine Smart Decision
Defined values
nt
ia
lF
ile
<pin>
String type values.
<newpin>
String type values.
<code>
Values reserved by the present document:
READY
– ME is not pending for any password
SIM PIN
– ME is waiting SIM PIN to be given
SIM PUK
– ME is waiting SIM PUK to be given
PH-SIM PIN – ME is waiting phone-to-SIM card password to be given
SIM PIN2
– ME is waiting SIM PIN2 to be given
SIM PUK2
– ME is waiting SIM PUK2 to be given
PH-NET PIN – ME is waiting network personalization password to be given
id
e
Examples
4.3
C
on
f
AT+CPIN?
+CPIN: SIM PUK2
OK
AT+CICCID Read ICCID from SIM card
Description
This command is used to Read the ICCID from SIM card
SIM PIN
Vendor
C
om
NO
References
Syntax
Responses
OK
Execution Command
AT+CICCID
Responses
+ICCID: <ICCID>
OK
SI
M
Test Command
AT+CICCID=?
ERROR
+CME ERROR: <err>
Defined values
<ICCID>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
31
2019-11-21
Smart Machine Smart Decision
lF
ile
Integrate circuit card identity, a standard ICCID is a 20-digit serial number of the SIM card,
it presents the publish state, network code, publish area, publish date, publish manufacture and
press serial number of the SIM card.
Examples
AT+CICCID
+ICCID: 898600700907A6019125
OK
AT+CSIM Generic SIM access
ia
4.4
nt
Description
SIM PIN
NO
C
on
f
id
e
This command is used to control the SIM card directly.
Compared to restricted SIM access command AT+CRSM, AT+CSIM allows the ME to take more
control over the SIM interface.
For SIM–ME interface please refer 3GPP TS 11.11.
NOTE:The SIM Application Toolkit functionality is not supported by AT+CSIM. Therefore the
following SIM commands can not be used: TERMINAL PROFILE, ENVELOPE,
FETCH and TEMINAL RESPONSE.
References
3GPP TS 27.007
Syntax
C
om
Test Command
AT+CSIM=?
Responses
+CSIM: <length>, <response>
OK
ERROR
+CME ERROR: <err>
M
Write Command
AT+CSIM=<length>,<com
mand>
Responses
OK
SI
Defined values
<length>
Interger type; length of characters that are sent to TE in <command> or <response>
<command>
Command passed from MT to SIM card.
<response>
Response to the command passed from SIM card to MT.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
32
2019-11-21
Smart Machine Smart Decision
Examples
4.5
lF
ile
AT+CSIM=?
OK
AT+CRSM Restricted SIM access
Description
SIM PIN
NO
id
e
nt
ia
By using AT+CRSM instead of Generic SIM Access AT+CSIM, TE application has easier but
more limited access to the SIM database.
Write command transmits to the MT the SIM <command> and its required parameters. MT handles
internally all SIM-MT interface locking and file selection routines. As response to the command,
MT sends the actual SIM information parameters and response data. MT error result code +CME
ERROR may be returned when the command cannot be passed to the SIM, but failure in the
execution of the command in the SIM is reported in <sw1> and <sw2> parameters.
References
3GPP TS 27.007
Test Command
AT+CRSM=?
C
on
f
Syntax
C
om
Write Command
AT+CRSM=<command>[,<f
ileID>[,<p1>,<p2>, <p3>
[,<data>]]]
Responses
OK
Responses
+CRSM: <sw1>,<sw2>[,<response>]
OK
ERROR
+CME ERROR: <err>
Defined values
SI
M
<command>
Command passed on by the MT to the SIM:
176 – READ BINARY
178 – READ RECORD
192 – GET RESPONSE
214 – UPDATE BINARY
220 – UPDATE RECORD
242 – STATUS
203 – RETRIEVE DATA
219 – SET DATA
<fileID>
Identifier for an elementary data file on SIM, if used by <command>.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
33
2019-11-21
SI
M
C
om
C
on
f
id
e
nt
ia
The following list the fileID hex value, user needs to convet them to decimal.
EFs under MF
0x2FE2
ICCID
0x2F05
Extended Language Preferences
0x2F00
EF DIR
0x2F06
Access Rule Reference
EFs under USIM ADF
0x6F05
Language Indication
0x6F07
IMSI
0x6F08
Ciphering and Integrity keys
0x6F09
C and I keys for pkt switched domain
0x6F60
User controlled PLMN selector w/Acc Tech
0x6F30
User controlled PLMN selector
0x6F31
HPLMN search period
0x6F37
ACM maximum value
0x6F38
USIM Service table
0x6F39
Accumulated Call meter
0x6F3E
Group Identifier Level
0x6F3F
Group Identifier Level 2
0x6F46
Service Provider Name
0x6F41
Price Per Unit and Currency table
0x6F45
Cell Bcast Msg identifier selection
0x6F78
Access control class
0x6F7B
Forbidden PLMNs
0x6F7E
Location information
0x6FAD
Administrative data
0x6F48
Cell Bcast msg id for data download
0x6FB7
Emergency call codes
0x6F50
Cell bcast msg id range selection
0x6F73
Packet switched location information
0x6F3B
Fixed dialling numbers
0x6F3C
Short messages
0x6F40
MSISDN
0x6F42
SMS parameters
0x6F43
SMS Status
0x6F49
Service dialling numbers
0x6F4B
Extension 2
0x6F4C
Extension 3
0x6F47
SMS reports
0x6F80
Incoming call information
0x6F81
Outgoing call information
0x6F82
Incoming call timer
0x6F83
Outgoing call timer
lF
ile
Smart Machine Smart Decision
SIM7906_SIM7912 Series_AT Command Manual_V1.01
34
2019-11-21
Smart Machine Smart Decision
C
on
f
id
e
nt
ia
lF
ile
Extension 5
Capability Config Parameters 2
Enh Multi Level Precedence and Pri
Automatic answer for eMLPP service
Group identity
Key for hidden phonebook entries
Barred dialling numbers
Extension 4
Comparison Method information
Enabled services table
Access Point Name Control List
De-personalization Control Keys
Co-operative network list
Hyperframe number
Maximum value of Hyperframe number
OPLMN selector with access tech
OPLMN selector
HPLMN selector with access technology
Access Rule reference
RPLMN last used access tech
Network Parameters
CPHS: Voice Mail Waiting Indicator
CPHS: Service String Table
CPHS: Call Forwarding Flag
CPHS: Operator Name String
CPHS: Customer Service Profile
CPHS: CPHS Information
CPHS: Mailbox Number
PLMN Network Name
Operator PLMN List
Dynamic Flags Status
Dynamic2 Flag Setting
Customer Service Profile Line2
EF PARAMS - Welcome Message
Phone book reference file
Phone book synchronization center
Change counter
Previous Unique Identifier
GPRS ciphering key
CPBCCH information
Investigation scan
MExE Service table
Operator Root Public Key
SI
M
C
om
0x6F4E
0x6F4F
0x6FB5
0x6FB6
0x6FC2
0x6FC3
0x6F4D
0x6F55
0x6F58
0x6F56
0x6F57
0x6F2C
0x6F32
0x6F5B
0x6F5C
0x6F61
0x6F5D
0x6F62
0x6F06
0x6F65
0x6FC4
0x6F11
0x6F12,
0x6F13
0x6F14
0x6F15
0x6F16
0x6F17
0x6FC5
0x6FC6
0x6F9F
0x6F92
0x6F98
0x6F9B
0x4F30
0x4F22
0x4F23
0x4F24
0x4F52
0x4F63
0x4F64
0x4F40
0x4F41
SIM7906_SIM7912 Series_AT Command Manual_V1.01
35
2019-11-21
SI
ia
nt
M
C
om
C
on
f
id
e
0x4F42
Administrator Root Public Key
0x4F43
Third party Root public key
0x6FC7
Mail Box Dialing Number
0x6FC8
Extension 6
0x6FC9
Mailbox Identifier
0x6FCA
Message Waiting Indication Status
0x6FCD
Service Provider Display Information
0x6FD2
UIM_USIM_SPT_TABLE
0x6FD9
Equivalent HPLMN
0x6FCB
Call Forwarding Indicator Status
0x6FD6
GBA Bootstrapping parameters
0x6FDA
GBA NAF List
0x6FD7
MBMS Service Key
0x6FD8
MBMS User Key
0x6FCE
MMS Notification
0x6FD0
MMS Issuer connectivity parameters
0x6FD1
MMS User Preferences
0x6FD2
MMS User connectivity parameters
0x6FCF
Extension 8
0x5031
Object Directory File
0x5032
Token Information File
0x5033
Unused space Information File
EFs under Telecom DF
0x6F3A
Abbreviated Dialing Numbers
0x6F3B
Fixed dialling numbers
0x6F3C
Short messages
0x6F3D
Capability Configuration Parameters
0x6F4F
Extended CCP
0x6F40
MSISDN
0x6F42
SMS parameters
0x6F43
SMS Status
0x6F44
Last number dialled
0x6F49
Service Dialling numbers
0x6F4A
Extension 1
0x6F4B
Extension 2
0x6F4C
Extension 3
0x6F4D
Barred Dialing Numbers
0x6F4E
Extension 4
0x6F47
SMS reports
0x6F58
Comparison Method Information
0x6F54
Setup Menu elements
0x6F06
Access Rule reference
0x4F20
Image
lF
ile
Smart Machine Smart Decision
SIM7906_SIM7912 Series_AT Command Manual_V1.01
36
2019-11-21
Smart Machine Smart Decision
id
e
nt
ia
lF
ile
0x4F30
Phone book reference file
0x4F22
Phone book synchronization center
0x4F23
Change counter
0x4F24
Previous Unique Identifier
<p1> <p2> <p3>
Integer type; parameters to be passed on by the Module to the SIM.
<data>
Information which shall be written to the SIM (hexadecimal character format, refer AT+CSCS).
<sw1> <sw2>
Status information from the SIM about the execution of the actual command. It is returned in both
cases, on successful or failed execution of the command.
<response>
Response data in case of a successful completion of the previously issued command.
“STATUS” and “GET RESPONSE” commands return data, which gives information about the
currently selected elementary data field. This information includes the type of file and its size.
After “READ BINARY” or “READ RECORD” commands the requested data will be returned.
<response> is empty after “UPDATE BINARY” or “UPDATE RECORD” commands.
AT+CRSM=?
OK
4.6
C
on
f
Examples
AT+SPIC Times remain to input SIM PIN/PUK
Description
This command is used to inquire times remain to input SIM PIN/PUK.
References
C
om
SIM PIN
NO
Vendor
Syntax
M
Test Command
AT+SPIC=?
SI
Execution Command
AT+SPIC
Responses
OK
Responses
+SPIC: <pin1>,<puk1>,<pin2>,<puk2>
OK
Defined values
<pin1>
Times remain to input PIN1 code.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
37
2019-11-21
Smart Machine Smart Decision
lF
ile
<puk1>
Times remain to input PUK1 code.
<pin2>
Times remain to input PIN2 code.
<puk2>
Times remain to input PUK2 code.
Examples
nt
AT+CSPN Get service provider name from SIM
id
e
4.7
ia
AT+SPIC=?
OK
AT+SPIC
+SPIC: 3,10,0,10
OK
Description
SIM PIN
YES
C
on
f
This command is used to get service provider name from SIM card.
References
Vendor
Syntax
C
om
Test Command
AT+CSPN=?
M
Read Command
AT+CSPN?
Responses
OK
ERROR
Responses
+CSPN: <spn>,<display mode>
OK
OK
ERROR
+CME ERROR: <err>
SI
Defined values
<spn>
String type; service provider name on SIM
<display mode>
0 – doesn’t display PLMN. Already registered on PLMN.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
38
2019-11-21
Smart Machine Smart Decision
1
– display PLMN
Examples
AT+CSQ Query signal quality
ia
4.8
lF
ile
AT+CSPN=?
OK
AT+CSPN?
+CSPN: “CMCC”,0
OK
nt
Description
SIM PIN
NO
id
e
This command is used to return received signal strength indication <rssi> and channel bit error rate
<ber> from the ME. Test command returns values supported by the TA as compound values.
References
3GPP TS 27.007
Test Command
AT+CSQ=?
C
on
f
Syntax
Responses
+CSQ: (list of supported <rssi>s),(list of supported <ber>s)
OK
Responses
+CSQ: <rssi>,<ber>
OK
C
om
Execution Command
AT+CSQ
ERROR
Defined values
SI
M
<rssi>
0
–
1
–
2...30
–
31
–
99
–
100
–
101
–
102…191 –
191
–
199
–
<ber>
-113 dBm or less
-111 dBm
-109... -53 dBm
-51 dBm or greater
not known or not detectable
-116 dBm or less
-115 dBm
-114... -26dBm
-25 dBm or greater
not known or not detectable
SIM7906_SIM7912 Series_AT Command Manual_V1.01
39
2019-11-21
Smart Machine Smart Decision
lF
ile
<0.01%
0.01% --- 0.1%
0.1% --- 0.5%
0.5% --- 1.0%
1.0% --- 2.0%
2.0% --- 4.0%
4.0% --- 8.0%
>=8.0%
not known or not detectable
ia
(in percent)
0
–
1
–
2
–
3
–
4
–
5
–
6
–
7
–
99 –
Examples
AT+AUTOCSQ
id
e
4.9
nt
AT+CSQ
+CSQ: 22,0
OK
Set CSQ report
C
on
f
Description
This command is used to enable or disable automatic report CSQ information, when automatic
report enabled, the module reports CSQ information every five seconds or only after <rssi> or
<ber> is changed, the format of automatic report is “+CSQ: <rssi>,<ber>”.
SIM PIN
NO
References
Vendor
C
om
Syntax
Responses
+AUTOCSQ: (list of supported<auto>s),(list of supported<mod
e>s)
OK
Read Command
AT+AUTOCSQ?
Responses
+AUTOCSQ: <auto>,<mode>
OK
SI
M
Test Command
AT+AUTOCSQ=?
Write Command
AT+AUTOCSQ=<auto>[,<
mode>]
Responses
OK
ERROR
Defined values
<auto>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
40
2019-11-21
Smart Machine Smart Decision
lF
ile
0 – disable automatic report
1 – enable automatic report
<mode>
0 – CSQ automatic report every five seconds
1 – CSQ automatic report only after <rssi> or <ber> is changed
NOTE: If the parameter of <mode> is omitted when executing write command, <mode> will be set
to default value.
nt
AT+CSQDELTA Set RSSI delta change threshold
Description
C
on
f
4.10
id
e
AT+AUTOCSQ=?
+AUTOCSQ: (0-1),(0-1)
OK
AT+AUTOCSQ?
+AUTOCSQ: 1,1
OK
AT+AUTOCSQ=1,1
OK
+CSQ: 23,0 (when <rssi> or <ber> changing)
ia
Examples
This command is used to set RSSI delta threshold for signal strength reporting.
SIM PIN
Vendor
C
om
NO
References
Syntax
Responses
+CSQDELTA: (list of supported <delta>s)
OK
Read Command
AT+CSQDELTA?
Responses
+CSQDELTA: <delta>
SI
M
Test Command
AT+CSQDELTA=?
Write Command
AT+CSQDELTA=<delta>
OK
ERROR
Responses
OK
ERROR
Execution Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
41
2019-11-21
Smart Machine Smart Decision
Set default value(<delta>=5):
OK
AT+CSQDELTA
lF
ile
Defined values
<delta>
Range: from 0 to 5.
Examples
id
e
4.11 AT+CPOF Power down the module
nt
ia
AT+CSQDELTA?
+CSQDELTA: 5
OK
Description
This command is used to power off the module. Once the AT+CPOF command is executed, The
module will store user data and deactivate from network, and then shutdown.
NO
References
C
on
f
SIM PIN
Vendor
Syntax
Test Command
AT+CPOF=?
C
om
Execution Command
AT+CPOF
Responses
OK
Responses
OK
Examples
M
AT+CPOF
OK
4.12
AT+CRESET Reset the module
SI
Description
This command is used to reset the module.
SIM PIN
NO
References
Vendor
SIM7906_SIM7912 Series_AT Command Manual_V1.01
42
2019-11-21
Smart Machine Smart Decision
Test Command
AT+CRESET=?
Responses
OK
Execution Command
AT+CRESET
Responses
OK
lF
ile
Syntax
Examples
Accumulated call meter
nt
AT+CACM
id
e
4.13
ia
AT+CRESET=?
OK
AT+CRESET
OK
Description
This command is used to reset the Advice of Charge related accumulated call meter value in SIM
file EFACM.
YES
References
C
on
f
SIM PIN
3GPP TS 27.007
Syntax
C
om
Test Command
AT+CACM=?
Read Command
AT+CACM?
SI
M
Write Command
AT+CACM=<passwd>
Responses
OK
ERROR
Responses
+CACM: <acm>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Execution Command
Responses
AT+CACM
OK
ERROR
SIM7906_SIM7912 Series_AT Command Manual_V1.01
43
2019-11-21
Smart Machine Smart Decision
+CME ERROR: <err>
lF
ile
Defined values
<passwd>
String type, SIM PIN2.
<acm>
String type, accumulated call meter value similarly coded as <ccm> under +CAOC.
ia
Examples
AT+CAMM
Accumulated call meter maximum
id
e
4.14
nt
AT+CACM?
+CACM: "000000"
OK
Description
SIM PIN
YES
C
on
f
This command is used to set the Advice of Charge related accumulated call meter maximum value
in SIM file EFACMmax.
References
3GPP TS 27.007
Syntax
C
om
Test Command
AT+CAMM=?
SI
M
Read Command
AT+CAMM?
Write Command
AT+CAMM=
<acmmax>[,<passwd>]
Execution Command
AT+CAMM
Responses
OK
ERROR
Responses
+CAMM: <acmmax>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
SIM7906_SIM7912 Series_AT Command Manual_V1.01
44
2019-11-21
Smart Machine Smart Decision
+CME ERROR: <err>
lF
ile
Defined values
<acmmax>
String type, accumulated call meter maximum value similarly coded as <ccm> under AT+CAOC,
value zero disables ACMmax feature.
<passwd>
String type, SIM PIN2.
ia
Examples
id
e
4.15
nt
AT+CAMM?
+CAMM: "000000"
OK
AT+CPUC Price per unit and currency table
Description
SIM PIN
YES
C
on
f
This command is used to set the parameters of Advice of Charge related price per unit and currency
table in SIM file EFPUCT..
References
3GPP TS 27.007
Syntax
C
om
Test Command
AT+CPUC=?
SI
M
Read Command
AT+CPUC?
Write Command
AT+CPUC=<currency>,<pp
u>[,<passwd>]
Responses
OK
ERROR
Responses
+CPUC: [<currency>,<ppu>]
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
SIM7906_SIM7912 Series_AT Command Manual_V1.01
45
2019-11-21
Smart Machine Smart Decision
lF
ile
<currency>
String type, three-character currency code (e.g. "GBP", "DEM"), character set as specified by
command Select TE Character Set AT+CSCS.
<ppu>
String type, price per unit, dot is used as a decimal separator. (e.g. "2.66").
<passwd>
String type, SIM PIN2.
Examples
nt
AT+CCLK
Real time clock management
id
e
4.16
ia
AT+CPUC?
+CPUC: “GBP” , “2.66”
OK
Description
This command is used to manage Real Time Clock of the module.
NO
References
3GPP TS 27.007
Syntax
Test Command
AT+CCLK=?
C
om
Read Command
AT+CCLK?
C
on
f
SIM PIN
Write Command
AT+CCLK=<time>
Responses
OK
Responses
+CCLK: <time>
OK
Responses
OK
ERROR
SI
M
Defined values
<time>
String type value; format is “yy/MM/dd,hh:mm:ss±zz”, where characters indicate year (two last
digits), month, day, hour, minutes, seconds and time zone (indicates the difference, expressed in
quarters of an hour, between the local time and GMT; three last digits are mandatory, range
-47…+48). E.g. 6th of May 2008, 14:28:10 GMT+8 equals to “08/05/06,14:28:10+32”.
NOTE: 1. Time zone is nonvolatile, and the factory value is invalid time zone.
2. Command +CCLK? will return time zone when time zone is valid, and if time zone is
SIM7906_SIM7912 Series_AT Command Manual_V1.01
46
2019-11-21
Smart Machine Smart Decision
00, command +CCLK? will return “+00”, but not “-00”.
Examples
ia
nt
AT+CMEE
Report mobile equipment error
id
e
4.17
lF
ile
AT+CCLK=“08/11/28,12:30:33+32”
OK
AT+CCLK?
+CCLK: “08/11/28,12:30:35+32”
OK
AT+CCLK=“08/11/26,10:15:00”
OK
AT+CCLK?
+CCLK: “08/11/26,10:15:02+32”
OK
Description
SIM PIN
NO
C
on
f
This command is used to disable or enable the use of result code “+CME ERROR: <err>” or
“+CMS ERROR: <err>” as an indication of an error relating to the functionality of ME; when
enabled, the format of <err> can be set to numeric or verbose string.
References
3GPP TS 27.007
Syntax
Responses
+CMEE: (list of supported <n>s)
OK
Read Command
AT+CMEE?
Responses
+CMEE: <n>
OK
Write Command
Responses
SI
M
C
om
Test Command
AT+CMEE=?
AT+CMEE=<n>
OK
Execution Command
AT+CMEE
ERROR
Responses
Set default value:
OK
Defined values
SIM7906_SIM7912 Series_AT Command Manual_V1.01
47
2019-11-21
Smart Machine Smart Decision
<n>
– Disable result code,i.e. only “ERROR” will be displayed.
– Enable error result code with numeric values.
– Enable error result code with string values.
lF
ile
0
1
2
4.18
AT+CPAS
Description
nt
id
e
C
on
f
AT+CMEE?
+CMEE: 2
OK
AT+CPIN="1234","1234"
+CME ERROR: incorrect password
AT+CMEE=0
OK
AT+CPIN="1234","1234"
ERROR
AT+CMEE=1
OK
AT+CPIN="1234","1234"
+CME ERROR: 16
ia
Examples
Phone activity status
C
om
This command is used to return the activity status <pas> of the ME. It can be used to interrogate the
ME before requesting action from the phone.
NOTE: This command is same as AT+CLCC, but AT+CLCC is more commonly used. So
AT+CLCC is recommended to use.
SIM PIN
NO
References
3GPP TS 27.007
Syntax
Responses
+CPAS: (list of supported <pas>s)
OK
Execution Command
AT+CPAS
Responses
+CPAS: <pas>
OK
SI
M
Test Command
AT+CPAS=?
Defined values
SIM7906_SIM7912 Series_AT Command Manual_V1.01
48
2019-11-21
Smart Machine Smart Decision
– ready (ME allows commands from TA/TE)
– ringing (ME is ready for commands from TA/TE, but the ringer is active)
– call in progress (ME is ready for commands from TA/TE, but a call is in progress)
lF
ile
<pas>
0
3
4
Examples
nt
AT+SIMEI Set IMEI for the module
id
e
4.19
ia
RING (with incoming call)
AT+CPAS
+CPAS: 3
OK
AT+CPAS=?
+CPAS: (0,3,4)
OK
Description
SIM PIN
NO
C
on
f
This command is used to set the module’s IMEI value.
References
Vendor
Syntax
C
om
Test Command
AT+SIMEI=?
Read Command
AT+SIMEI?
M
Write Command
AT+SIMEI=<imei>
Responses
OK
Responses
+SIMEI: <imei>
OK
ERROR
Responses
OK
ERROR
SI
Defined values
<imei>
The 15-digit IMEI value.
Examples
SIM7906_SIM7912 Series_AT Command Manual_V1.01
49
2019-11-21
AT+SIMEI=357396012183170
OK
AT+SIMEI?
+SIMEI: 357396012183170
OK
AT+SIMEI=?
OK
AT+CUSBPIDSWITCH Change module’s PID
ia
4.20
lF
ile
Smart Machine Smart Decision
Description
NO
References
Vendor
id
e
SIM PIN
nt
Execution command change the module’s PID. This command will reset the module if change to
other PID (not current used PID).
Syntax
Responses
+CUSBPIDSWITCH:
(9000,9001,9002,9003,9004,9005,9006,9007,9011,9016,9018,9019
,901A,901B,9020,9021,9022,9023,9024,9025,9026,9027,9028,902
9,902A),(0-1),(0-1)
OK
C
on
f
Test Command
AT+CUSBPIDSWITCH=?
ERROR
C
om
Read Command
AT+CUSBPIDSWITCH?
Responses
+CUSBPIDSWITCH: <pid>
OK
ERROR
Write Command
Responses
AT+CUSBPIDSWITCH=<p
id>, < reserve1>,< reserve2>
OK
M
ERROR
SI
Defined values
<pid>
This command support pids, 9001 is the default value.
9000,9001,9002,9003,9004,9005,9006,9007,9011,9016,9018,9019,901A,901B,9020,9021,9022,90
23,9024,9025,9026,9027,9028,9029,902A
< reserve1>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
50
2019-11-21
Smart Machine Smart Decision
lF
ile
0 or 1, this value is for the reserve
< reserve2>
0 or 1, this value is for the reserve
Examples
nt
SI
M
C
om
C
on
f
id
e
PID configuration:
9000:Diag, NMEA, At, Modem, Audio, Rmnet
9001:Diag, NMEA, At, Modem, Audio, Rmnet
9002:Diag, NMEA, At, Modem, Audio, Rmnet
9003:Diag, NMEA, At, Modem, Audio, MBIM
9004:Diag, NMEA, At, Modem, Audio, GNSS, Rmnet
9005:Diag, NMEA, At, Modem, Audio, GNSS, MBIM
9006:Diag, NMEA, At,Modem
9007:Diag, NMEA, At, Modem, Audio, Rmnet,mass_storage
9011:RNDIS,Diag, NMEA, At, Modem, Audio
9016:Diag, Rmnet
9018:Diag, NMEA, At, Modem, Audio, Ecm
9019:RNDIS
901A: Diag, NMEA, At, Rmnet
901B:NMEA, At, Rmnet
9020: Diag, At, Modem
9021: Diag, Modem
9022: Diag, Modem, Rmnet
9023: Modem
9024: At, Modem
9025: Modem,rmnet
9026: Modem,Audio
9027: Modem,Audio, Rmnet
9028:Diag, Modem,Audio, Rmnet
9029:Diag, Modem,Audio
902A: At
ia
AT+CUSBPIDSWITCH?
+CUSBPIDSWITCH: 9001
OK
AT+CUSBPIDSWITCH=9001,1,1
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
51
2019-11-21
Smart Machine Smart Decision
5.1
AT Commands for Network
lF
ile
5
AT+CREG Network registration
Description
NO
References
id
e
SIM PIN
nt
ia
This command is used to control the presentation of an unsolicited result code +CREG: <stat>
when <n>=1 and there is a change in the ME network registration status, or code +CREG:
<stat>[,<lac>,<ci>] when <n>=2 and there is a change of the network cell.
Read command returns the status of result code presentation and an integer <stat> which shows
whether the network has currently indicated the registration of the ME. Location information
elements <lac> and <ci> are returned only when <n>=2 and ME is registered in the network.
3GPP TS 27.007
Syntax
Read Command
AT+CREG?
Responses
+CREG: (list of supported <n>s)
OK
C
on
f
Test Command
AT+CREG=?
Responses
+CREG: <n>,<stat>[,<lac>,<ci>]
OK
C
om
ERROR
Write Command
AT+CREG=<n>
SI
M
Execution Command
AT+CREG
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
Set default value(<n>=0):
OK
Defined values
<n>
0
1
2
– disable network registration unsolicited result code
– enable network registration unsolicited result code +CREG: <stat>
– enable network registration and location information unsolicited result code +CREG:
SIM7906_SIM7912 Series_AT Command Manual_V1.01
52
2019-11-21
Smart Machine Smart Decision
nt
id
e
NOTE: The <lac> not supported in CDMA/HDR mode
<ci>
Cell Identify in hexadecimal format.
GSM : Maximum is two byte
WCDMA : Maximum is four byte
TDS-CDMA : Maximum is four byte
ia
lF
ile
<stat>[,<lac>,<ci>]
<stat>
0 – not registered, ME is not currently searching a new operator to register to
1 – registered, home network
2 – not registered, but ME is currently searching a new operator to register to
3 – registration denied
4 – unknown
5 – registered, roaming
6 – Internal use only
<lac>
Two byte location area code in hexadecimal format (e.g.”00C3” equals 193 in decimal).
Examples
AT+CREG?
+CREG: 0,1
OK
AT+COPS
Operator selection
C
om
5.2
C
on
f
NOTE: The <ci> not supported in CDMA/HDR mode
SI
M
Description
SIM7906_SIM7912 Series_AT Command Manual_V1.01
53
2019-11-21
Smart Machine Smart Decision
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+COPS=?
C
on
f
SIM PIN
id
e
nt
ia
lF
ile
Write command forces an attempt to select and register the UMTS network operator. <mode> is
used to select whether the selection is done automatically by the ME or is forced by this command
to operator <oper> (it shall be given in format <format>). If the selected operator is not available,
no other operator shall be selected (except <mode>=4). The selected operator name format shall
apply to further read commands (AT+COPS?) also. <mode>=2 forces an attempt to deregister from
the network. The selected mode affects to all further network registration (e.g. after <mode>=2, ME
shall be unregistered until <mode>=0 or 1 is selected).
Read command returns the current mode and the currently selected operator. If no operator is
selected, <format> and <oper> are omitted.
Test command returns a list of quadruplets, each representing an operator present in the network.
Quadruplet consists of an integer indicating the availability of the operator <stat>, long and short
alphanumeric format of the name of the operator, and numeric format representation of the operator.
Any of the formats may be unavailable and should then be an empty field. The list of operators shall
be in order: home network, networks referenced in SIM, and other networks.
It is recommended (although optional) that after the operator list TA returns lists of supported
<mode>s and <format>s. These lists shall be delimited from the operator list by two commas.
When executing AT+COPS=? , any input from serial port will stop this command.
Responses
[+COPS: [list of supported (<stat>,long alphanumeric <oper>
,short alphanumeric <oper>,numeric <oper>[,< AcT>])s]
[,,(list of supported <mode>s),(list of supported <format>s)]]
C
om
OK
SI
M
Read Command
AT+COPS?
Write Command
AT+COPS=<mode>[,<form
at>[,<oper>[,< AcT>]]]
ERROR
+CME ERROR: <err>
Responses
+COPS: <mode>[,<format>,<oper>[,< AcT>]]
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Execution Command
AT+COPS
Responses
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
54
2019-11-21
Smart Machine Smart Decision
Defined values
lF
ile
automatic
manual
force deregister
set only <format>
manual/automatic
manual,but do not modify the network selection mode(e.g WCDMA) after module
resets.
ia
<mode>
0 –
1 –
2 –
3 –
4 –
5 –
C
om
C
on
f
id
e
nt
NOTE: if <mode> is set to 1, 4, 5 in write command, the <oper> is needed.
<format>
0 – long format alphanumeric <oper>
1 – short format alphanumeric <oper>
2 – numeric <oper>
<oper>
string type, <format> indicates if the format is alphanumeric or numeric.
<stat>
0 – unknown
1 – available
2 – current
3 – forbidden
<AcT>
Access technology selected
2 – UTRAN
7 – EUTRAN
Examples
SI
M
AT+COPS?
+COPS: 0,0,"China Mobile Com",0
OK
AT+COPS=?
+COPS: (2,"China Unicom","Unicom","46001",0),(3,"China Mobile Com","DGTMPT",
"46000",0),,(0,1,2,3,4,5),(0,1,2)
OK
5.3
AT+CLCK
Facility lock
Description
SIM7906_SIM7912 Series_AT Command Manual_V1.01
55
2019-11-21
Smart Machine Smart Decision
SIM PIN
YES
lF
ile
This command is used to lock, unlock or interrogate a ME or a network facility <fac>. Password is
normally needed to do such actions. When querying the status of a network service (<mode>=2) the
response line for 'not active' case (<status>=0) should be returned only if service is not active for
any <class>.
References
3GPP TS 27.007
Test Command
AT+CLCK=?
Responses
+CLCK: (list of supported <fac>s)
ERROR
Write Command
AT+CLCK=<fac>,<mode>
[,<passwd>[,<class>]]
Responses
OK
id
e
+CME ERROR: <err>
nt
OK
ia
Syntax
When <mode>=2 and command successful:
+CLCK:<status>[,<class1>[<CR><LF>
C
on
f
+CLCK: <status>,<class2>
[...]]
OK
ERROR
+CME ERROR: <err>
C
om
Defined values
SI
M
<fac>
"PF"
"SC"
"AO"
"OI"
"OX"
"AI"
"IR"
"AB"
"AG"
"AC"
"FD"
"PN"
"PU"
"PP"
lock Phone to the very First inserted SIM card or USIM card
lock SIM card or USIM card
Barr All Outgoing Calls
Barr Outgoing International Calls
Barr Outgoing International Calls except to Home Country
Barr All Incoming Calls
Barr Incoming Calls when roaming outside the home country
All Barring services (only for <mode>=0)
All outGoing barring services (only for <mode>=0)
All inComing barring services (only for <mode>=0)
SIM fixed dialing memory feature
Network Personalization
network subset Personalization
service Provider Personalization
SIM7906_SIM7912 Series_AT Command Manual_V1.01
56
2019-11-21
Smart Machine Smart Decision
Examples
C
on
f
id
e
nt
ia
lF
ile
"PC"
Corporate Personalization
<mode>
0 – unlock
1 – lock
2 – query status
<status>
0 – not active
1 – active
<passwd>
Password.
string type; shall be the same as password specified for the facility from the ME user interface or
with command Change Password +CPWD
<classX>
It is a sum of integers each representing a class of information (default 7):
1
– voice (telephony)
2
– data (refers to all bearer services)
4
– fax (facsimile services)
8
– short message service
16
– data circuit sync
32 – data circuit async
64
– dedicated packet access
128 – dedicated PAD access
255 – The value 255 covers all classes
C
om
AT+CLCK="SC",2
+CLCK: 0
OK
5.4
AT+CPWD Change password
Description
SI
M
Write command sets a new password for the facility lock function defined by command Facility
Lock AT+CLCK.
Test command returns a list of pairs which present the available facilities and the maximum length
of their password.
SIM PIN
YES
References
3GPP TS 27.007
Syntax
SIM7906_SIM7912 Series_AT Command Manual_V1.01
57
2019-11-21
Smart Machine Smart Decision
Test Command
AT+CPWD=?
Responses
+CPWD: (list of supported (<fac>,<pwdlength>)s)
OK
lF
ile
ERROR
+CME ERROR: <err>
Write Command
AT+CPWD=
<fac>,<oldpwd>,<newpwd>
Responses
OK
ERROR
ia
+CME ERROR: <err>
nt
Defined values
C
om
C
on
f
id
e
<fac>
Refer Facility Lock +CLCK for other values:
"SC" SIM or USIM PIN1
"P2" SIM or USIM PIN2
"AB" All Barring services
"AC" All inComing barring services (only for <mode>=0)
"AG" All outGoing barring services (only for <mode>=0)
"AI" Barr All Incoming Calls
"AO" Barr All Outgoing Calls
"IR" Barr Incoming Calls when roaming outside the home country
"OI" Barr Outgoing International Calls
"OX" Barr Outgoing International Calls except to Home Country
<oldpwd>
String type, it shall be the same as password specified for the facility from the ME user interface or
with command Change Password AT+CPWD.
<newpwd>
String type, it is the new password; maximum length of password can be determined with
<pwdlength>.
<pwdlength>
Integer type, max length of password.
SI
M
Examples
AT+CPWD=?
+CPWD: ("AB",4),("AC",4),("AG",4),("AI",4),("AO",4),("IR",4),("OI",4),("OX",4),(
"SC",8),("P2",8)
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
58
2019-11-21
Smart Machine Smart Decision
5.5
AT+CCUG Closed user group
lF
ile
Description
This command allows control of the Closed User Group supplementary service. Set command
enables the served subscriber to select a CUG index, to suppress the Outgoing Access (OA), and to
suppress the preferential CUG.
YES
References
3GPP TS 27.007
ia
SIM PIN
Syntax
Responses
OK
nt
Test Command
AT+CCUG=?
Read Command
AT+CCUG?
id
e
ERROR
Responses
+CCUG: <n>,<index>,<info>
OK
C
on
f
ERROR
+CME ERROR: <err>
Write Command
AT+CCUG=
<n>[,<index>[,<info>]]
Responses
OK
ERROR
+CME ERROR: <err>
C
om
Execution Command
AT+CCUG
Responses
Set default value:
OK
Defined values
<n>
SI
M
0 – disable CUG temporary mode
1 – enable CUG temporary mode
<index>
0...9 – CUG index
10 – no index (preferred CUG taken from subscriber data)
<info>
0 – no information
1 – suppress OA
2 – suppress preferential CUG
3 – suppress OA and preferential CUG
SIM7906_SIM7912 Series_AT Command Manual_V1.01
59
2019-11-21
Smart Machine Smart Decision
AT+CCUG?
+CCUG: 0,0,0
OK
5.6
AT+CUSD
Unstructured supplementary service data
Description
lF
ile
Examples
YES
References
id
e
SIM PIN
nt
ia
This command allows control of the Unstructured Supplementary Service Data (USSD). Both
network and mobile initiated operations are supported. Parameter <n> is used to disable/enable the
presentation of an unsolicited result code (USSD response from the network, or network initiated
operation) +CUSD: <m>[,<str>,<dcs>] to the TE. In addition, value <n>=2 is used to cancel an
ongoing USSD session.
3GPP TS 27.007
Syntax
Responses
+CUSD: (list of supported <n>s)
C
on
f
Test Command
AT+CUSD=?
OK
Read Command
AT+CUSD?
Responses
+CUSD: <n>
OK
C
om
Write Command
AT+CUSD=
<n>[,<str>[,<dcs>]]
ERROR
+CME ERROR: <err>
Responses
Set default value (<n>=0):
OK
M
Execution Command
AT+CUSD
Responses
OK
SI
Defined values
<n>
0 – disable the result code presentation in the TA
1 – enable the result code presentation in the TA
2 – cancel session (not applicable to read command response)
<str>
String type USSD-string.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
60
2019-11-21
Smart Machine Smart Decision
ia
lF
ile
<dcs>
Cell Broadcast Data Coding Scheme in integer format (default 0).
<m>
0 – no further user action required (network initiated USSD-Notify, or no further
information needed after mobile initiated operation)
1 – further user action required (network initiated USSD-Request, or further information
needed after mobile initiated operation)
2 – USSD terminated by network
4 – operation not supported
5 – network time out
Examples
id
e
AT+CAOC Advice of charge
C
on
f
5.7
nt
AT+CUSD?
+CUSD: 1
OK
AT+CUSD=0
OK
Description
C
om
This command refers to Advice of Charge supplementary service that enables subscriber to get
information about the cost of calls. With <mode>=0, the execute command returns the current call
meter value from the ME.
This command also includes the possibility to enable an unsolicited event reporting of the CCM
information. The unsolicited result code +CCCM: <ccm> is sent when the CCM value changes, but
not more that every 10 seconds. Deactivation of the unsolicited event reporting is made with the
same command.
SIM PIN
YES
References
3GPP TS 27.007
M
Syntax
SI
Test Command
AT+CAOC=?
Responses
+CAOC: (list of supported <mode>s)
OK
ERROR
Read Command
AT+CAOC?
Responses
+CAOC: <mode>
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
61
2019-11-21
Smart Machine Smart Decision
ERROR
+CME ERROR: <err>
Responses
+CAOC: <ccm>
lF
ile
Write Command
AT+CAOC=<mode>
OK
OK
ERROR
+CME ERROR: <err>
ia
Responses
Set default value (<mode>=1):
OK
ERROR
nt
Execution Command
AT+CAOC
id
e
Defined values
Examples
C
on
f
<mode>
0 – query CCM value
1 – deactivate the unsolicited reporting of CCM value
2 – activate the unsolicited reporting of CCM value
<ccm>
String type, three bytes of the current call meter value in hexadecimal format (e.g. "00001E"
indicates decimal value 30), value is in home units and bytes are similarly coded as ACMmax value
in the SIM.
C
om
AT+CAOC=0
+CAOC: "000000"
OK
5.8
AT+CSSN Supplementary service notifications
SI
M
Description
SIM7906_SIM7912 Series_AT Command Manual_V1.01
62
2019-11-21
Smart Machine Smart Decision
nt
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+CSSN=?
id
e
SIM PIN
ia
lF
ile
This command refers to supplementary service related network initiated notifications. The set
command enables/disables the presentation of notification result codes from TA to TE.
When <n>=1 and a supplementary service notification is received after a mobile originated call
setup, intermediate result code +CSSI: <code1>[,<index>] is sent to TE before any other MO call
setup result codes presented in the present document. When several different <code1>s are received
from the network, each of them shall have its own +CSSI result code.
When <m>=1 and a supplementary service notification is received during a mobile terminated call
setup or during a call, or when a forward check supplementary service notification is received,
unsolicited result code +CSSU: <code2>[,<index>[,<number>,<type>[,<subaddr>,<satype>]]] is
sent to TE. In case of MT call setup, result code is sent after every +CLIP result code (refer
command "Calling line identification presentation +CLIP") and when several different <code2>s
are received from the network, each of them shall have its own +CSSU result code.
Responses
+CSSN: (list of supported <n>s),(list of supported <m>s)
C
on
f
OK
ERROR
Read Command
AT+CSSN?
Responses
+CSSN: <n>,<m>
OK
ERROR
C
om
Write Command
AT+CSSN=<n>[,<m>]
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
SI
M
<n>
Parameter sets/shows the +CSSI result code presentation status in the TA:
0 – disable
1 – enable
<m>
Parameter sets/shows the +CSSU result code presentation status in the TA:
0 – disable
1 – enable
<code1>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
63
2019-11-21
Smart Machine Smart Decision
Examples
C
om
AT+CSSN=1,1
OK
AT+CSSN?
+CSSN: 1,1
OK
C
on
f
id
e
nt
ia
lF
ile
0 – unconditional call forwarding is active
1 – some of the conditional call forwarding are active
2 – call has been forwarded
3 – call is waiting
5 – outgoing calls are barred
<index>
Refer "Closed user group +CCUG".
<code2>
0 – this is a forwarded call (MT call setup)
2 – call has been put on hold (during a voice call)
3 – call has been retrieved (during a voice call)
5 – call on hold has been released (this is not a SS notification) (during a voice call)
<number>
String type phone number of format specified by <type>.
<type>
Type of address octet in integer format; default 145 when dialing string includes international
access code character "+", otherwise 129.
<subaddr>
String type sub address of format specified by <satype>.
<satype>
Type of sub address octet in integer format, default 128.
5.9
AT+CPOL Preferred operator list
Description
M
This command is used to edit the SIM preferred list of networks.
SIM PIN
SI
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+CPOL=?
Responses
+CPOL: (list of supported <index>s), (list of supported <format>s)
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
64
2019-11-21
Smart Machine Smart Decision
ERROR
Responses
[+CPOL:<index1>,<format>,<oper1>[<GSM_AcT1>,<GSM_Com
pact_AcT1>,<UTRAN_AcT1>,<LTE_AcT1>][<CR><LF>
lF
ile
Read Command
AT+CPOL?
+CPOL:
<index2>,<format>,<oper2>[,<GSM_AcT1>,<GSM_Compact_Ac
T1>,<UTRAN_AcT1>,<LTE_AcT1>]
[...]]]
OK
Defined values
ERROR
id
e
+CME ERROR: <err>
nt
Responses
OK
C
on
f
Write Command
AT+CPOL=<index>
[,<format>[,<oper>][,<GSM
_AcT1>,<GSM_Compact_A
cT1>,<UTRAN_AcT1>,<LT
E_AcT1> ]]
NOTE: If using USIM card,
the last four parameters must
set.
ia
ERROR
SI
M
C
om
<index>
Integer type, the order number of operator in the SIM preferred operator list.
If only input <index>, command will delete the value indicate by <index>.
<format>
0 – long format alphanumeric <oper>
1 – short format alphanumeric <oper>
2 – numeric <oper>
<operX>
String type.
<GSM_AcTn>
GSM access technology:
0 – access technology not selected
1 – access technology selected
<GSM_Compact_AcTn>
GSM compact access technology:
0 – access technology not selected
1 – access technology selected
<UTRA_AcTn>
UTRA access technology:
0 – access technology not selected
SIM7906_SIM7912 Series_AT Command Manual_V1.01
65
2019-11-21
Smart Machine Smart Decision
lF
ile
1 – access technology selected
<LTE_AcTn>
LTE access technology:
0 – access technology not selected
1 – access technology selected
Examples
nt
AT+COPN Read operator names
id
e
5.10
ia
AT+CPOL?
+CPOL: 1,2,"46001",0,0,1,0
OK
AT+CPOL=?
+CPOL: (1-8),(0-2)
OK
Description
SIM PIN
YES
C
on
f
This command is used to return the list of operator names from the ME. Each operator code
<numericX> that has an alphanumeric equivalent <alphaX> in the ME memory shall be returned.
References
3GPP TS 27.007
Syntax
C
om
Test Command
AT+COPN=?
SI
M
Write Command
AT+COPN
Responses
OK
ERROR
Responses
+COPN:<numeric1>,<alpha1>[<CR><LF>
+COPN: <numeric2>,<alpha2>
[...]]
OK
ERROR
+CME ERROR: <err>
Defined values
<numericX>
String type, operator in numeric format (see AT+COPS).
<alphaX>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
66
2019-11-21
Smart Machine Smart Decision
String type, operator in long alphanumeric format (see AT+COPS).
Examples
AT+CNMP Preferred mode selection
ia
5.11
lF
ile
AT+COPN
+COPN: "46000","China Mobile Com"
+COPN: "46001"," China Unicom"
……
OK
nt
Description
SIM PIN
id
e
This command is used to select or set the state of the mode preference.
NOTE: The set value in Write Command will take efficient immediately; The set value will retain
after module reset;
NOTE: The response will be returned immediately for Test Command and Read Command; The
maximum response time for Write Command is 10 seconds.
References
Vendor
Syntax
Test Command
AT+CNMP=?
C
on
f
NO
Responses
+CNMP: (list of supported <mode>s)
OK
C
om
Read Command
AT+CNMP?
Responses
+CNMP: <mode>
OK
Responses
AT+CNMP=<mode>
OK
M
Write Command
If <mode> not supported by module, this command will return
ERROR.
ERROR
SI
Defined values
<mode>
2
14
38
54
–
–
–
–
Automatic
WCDMA Only
LTE Only
WCDMA+LTE Only
SIM7906_SIM7912 Series_AT Command Manual_V1.01
67
2019-11-21
Smart Machine Smart Decision
Examples
AT+CNBP Preferred band selection
Description
This command is used to select or set the state of the band preference.
nt
NO
References
Vendor
Syntax
id
e
SIM PIN
ia
5.12
lF
ile
AT+CNMP=2
OK
AT+CNMP?
+CNMP: 2
OK
Responses
AT+CNBP?
+CNBP: <mode>[,<lte_mode>][,<tds_mode>]
C
on
f
Test Command
OK
Write Command
AT+CNBP=<mode>[,<lte_
mode>][,<tds_mode>]
Defined values
Responses
OK
ERROR
SI
M
C
om
<mode>
64bit number, the value is “1” << “<pos>”, then or by bit.
Some special mode value declared below:
0x40000000
BAND_PREF_NO_CHANGE
<pos>
Value:
0xFFFFFFFF7FFFFFFF
Any (any value)
7
GSM_DCS_1800
8
GSM_EGSM_900
9
GSM_PGSM_900
16
GSM_450
17
GSM_480
18
GSM_750
19
GSM_850
20
GSM_RGSM_900
SIM7906_SIM7912 Series_AT Command Manual_V1.01
68
2019-11-21
Smart Machine Smart Decision
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
21
GSM_PCS_1900
22
WCDMA_IMT_2000
23
WCDMA_PCS_1900
24
WCDMA_III_1700
25
WCDMA_IV_1700
26
WCDMA_850
27
WCDMA_800
48
WCDMA_VII_2600
49
WCDMA_VIII_900
50
WCDMA_IX_1700
<lte_mode>
64/256 bit number, the value is “1” << “<lte_pos>”, then or by bit.
NOTE: FDD(band1 ~ band32, band66, band252 and band255), TDD(band33 ~ band42)
<lte_pos>
Value:
0x480000000000000000000000000000000000000000000002000007FF3FDF3FFF
Any (any value)
0
EUTRAN_BAND1(UL:1920-1980; DL:2110-2170)
1
EUTRAN_BAND2(UL:1850-1910; DL:1930-1990)
2
EUTRAN_BAND3(UL:1710-1785; DL:1805-1880)
3
EUTRAN_BAND4(UL:1710-1755; DL:2110-2155)
4
EUTRAN_BAND5(UL: 824-849; DL: 869-894)
5
EUTRAN_BAND6(UL: 830-840; DL: 875-885)
6
EUTRAN_BAND7(UL:2500-2570; DL:2620-2690)
7
EUTRAN_BAND8(UL: 880-915; DL: 925-960)
8
EUTRAN_BAND9(UL:1749.9-1784.9; DL:1844.9-1879.9)
9
EUTRAN_BAND10(UL:1710-1770; DL:2110-2170)
10
EUTRAN_BAND11(UL:1427.9-1452.9; DL:1475.9-1500.9)
11
EUTRAN_BAND12(UL:698-716; DL:728-746)
12
EUTRAN_BAND13(UL: 777-787; DL: 746-756)
13
EUTRAN_BAND14(UL: 788-798; DL: 758-768)
16
EUTRAN_BAND17(UL: 704-716; DL: 734-746)
17
EUTRAN_BAND18(UL: 815-830; DL: 860-875)
18
EUTRAN_BAND19(UL: 830-845; DL: 875-890)
19
EUTRAN_BAND20(UL: 832-862; DL: 791-821)
20
EUTRAN_BAND21(UL: 1447.9-1462.9; DL: 1495.9-1510.9)
22
EUTRAN_BAND23(UL: 2000-2020; DL: 2180-2200)
23
EUTRAN_BAND24(UL: 1626.5-1660.5; DL: 1525 -1559)
24
EUTRAN_BAND25(UL: 1850-1915; DL: 1930 -1995)
25
EUTRAN_BAND26(UL: 814-849; DL: 859 -894)
26
EUTRAN_BAND27(UL: 807.5-824; DL: 852 -869)
27
EUTRAN_BAND28(703-748; DL: 758-803)
28
EUTRAN_BAND29(UL:1850-1910 or 1710-1755;
SIM7906_SIM7912 Series_AT Command Manual_V1.01
69
2019-11-21
Smart Machine Smart Decision
C
om
C
on
f
id
e
nt
ia
lF
ile
DL:716-728)
29
EUTRAN_BAND30(UL: 2305-2315 ; DL: 2350 - 2360)
32
EUTRAN_BAND33(UL: 1900-1920; DL: 1900-1920)
33
EUTRAN_BAND34(UL: 2010-2025; DL: 2010-2025)
34
EUTRAN_BAND35(UL: 1850-1910; DL: 1850-1910)
35
EUTRAN_BAND36(UL: 1930-1990; DL: 1930-1990)
36
EUTRAN_BAND37(UL: 1910-1930; DL: 1910-1930)
37
EUTRAN_BAND38(UL: 2570-2620; DL: 2570-2620)
38
EUTRAN_BAND39(UL: 1880-1920; DL: 1880-1920)
39
EUTRAN_BAND40(UL: 2300-2400; DL: 2300-2400)
40
EUTRAN_BAND41(UL: 2496-2690; DL: 2496-2690)
41
EUTRAN_BAND42(UL: 3400-3600; DL: 3400-3600)
42
EUTRAN_BAND43(UL: 3600-3800; DL: 3600-3800)
65
EUTRAN_BAND66(UL: 1710-1780; DL: 2110-2200)
251
EUTRAN_BAND252(DL: 5150-5250)
254
EUTRAN_BAND255(DL: 5725-5850)
<tds_mode>
64bit number, the value is “1” << “<tds_pos>”, then or by bit.
<tds_pos>
Value:
0x000000000000003F
Any (any value)
0
TDS Band A (1900-1920 MHz, 2010-2020 MHz)
1
TDS Band B (1850-1910 MHz, 1930-1990 MHz)
2
TDS Band C (1910-1930 MHz)
3
TDS Band D (2570-2620 MHz)
4
TDS Band E (2300-2400 MHz)
5
TDS Band F (1880-1920 MHz)
Examples
SI
M
AT+CNBP=,0x0000000000000095
OK
AT+CNBP?
+CNBP:
0x0x0000000000400000,0x000000000000000000000000000000000000000000000000000000000
0000095,0x000000000000003F
AT+CNBP=,0x4800000000000000000000000000000000000000000000020000000000000095
OK
AT+CNBP?
+CNBP:
0x0x0000000000400000,0x480000000000000000000000000000000000000000000002000000000
0000095,0x000000000000003F
SIM7906_SIM7912 Series_AT Command Manual_V1.01
70
2019-11-21
Smart Machine Smart Decision
AT+CNAOP Acquisitions order preference
Description
This command is used to reset the state of acquisitions order preference.
SIM PIN
NO
References
Vendor
ia
Syntax
Responses
+CNAOP: <mode>[,<sys_mode1>,[<sys_mode2>[,<sys_mode3>[,
<sys_mode4>[,<sys_mode5>[,<sys_mode6>]]]]]]
nt
Read Command
AT+CNAOP?
Responses
OK
ERROR
C
on
f
Write Command
AT+CNAOP=<mode>[,<sys
_mode1>[,<sys_mode2>[,<sy
s_mode3>[,<sys_mode4>[,<s
ys_mode5>[,<sys_mode6>]]]
]]]
id
e
OK
Defined values
lF
ile
5.13
M
C
om
<mode>
7 – Acquistion by priority order list <sys_moden>s.
<sys_moden>
sys_mode values:
2 – CDMA
3 – GSM
4 – HDR
5 – WCDMA
9 – LTE
11 – TDSCDMA
SI
Examples
AT+CNAOP=7,9,5,3,11,2,4
OK
AT+CNAOP?
+CNAOP: 7,9,5,3,11,2,4
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
71
2019-11-21
Smart Machine Smart Decision
5.14
AT+CPSI Inquiring UE system information
lF
ile
Description
This command is used to return the UE system information.
NO
References
Vendor
ia
SIM PIN
Test Command
AT+CPSI=?
Responses
+CPSI: (scope of <time>)
Read Command
Responses
id
e
OK
nt
Syntax
If camping on a wcdma cell:
C
on
f
+CPSI: <System Mode>,<Operation Mode>,<MCC>-<MNC>,<
LAC>,<Cell ID>,<Frequency Band>,<PSC>,<Freq>,<SSC>,<EC
/IO>,<RSCP>,<Qual>,<RxLev>,<TXPWR>
OK
If camping on a lte cell:
M
C
om
+CPSI: <System Mode>,<Operation Mode>[,<MCC>-<MNC>,<
TAC>,<SCellID>,<PCellID>,<Frequency Band>,<earfcn>,<dlb
w>,<ulbw>,<RSRQ>,<RSRP>,<RSSI>,<RSSNR>]
OK
SI
Write Command
AT+CPSI=<time>
If no service:
+CPSI: NO SERVICE, Online
OK
If power-off mode:
+CPSI: NO SERVICE, Powering off
OK
ERROR
Responses
OK
ERROR
Defined values
<time>
The range is 0-255, unit is second, after set <time> will report the system information every the
SIM7906_SIM7912 Series_AT Command Manual_V1.01
72
2019-11-21
Smart Machine Smart Decision
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
seconds.
<System Mode>
System mode, values: “NO SERVICE”, “WCDMA”, “LTE”
If module in LIMITED SERVICE state and +CNLSA command is set to 1, the system mode will
display as “LTE-LIMITED”, “WCDMA-LIMITED”…
<Operation Mode>
UE operation mode, values: “Unknown”, “Online”, “Offline”, “Factory Test Mode”, “Reset”, “Low
Power Mode”.
<MCC>
Mobile Country Code (first part of the PLMN code)
<MNC>
Mobile Network Code (second part of the PLMN code)
<LAC>
Location Area Code (hexadecimal digits)
<Cell ID>
Service-cell Identify.
<Absolute RF Ch Num>
AFRCN for service-cell.
<Track LO Adjust>
Track LO Adjust
<C1>
Coefficient for base station selection
<C2>
Coefficient for Cell re-selection
<Frequency Band>
Frequency Band of active set
<PSC>
Primary synchronization code of active set.
<Freq>
Downlink frequency of active set.
<SSC>
Secondary synchronization code of active set
<EC/IO>
Ec/Io value
<RSCP>
Received Signal Code Power
<Qual>
Quality value for base station selection
<RxLev>
RX level value for base station selection
<TXPWR>
UE TX power in dBm. If no TX, the value is 500.
<Cpid>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
73
2019-11-21
C
on
f
Examples
id
e
nt
ia
Cell Parameter ID
<TAC>
Tracing Area Code
<PCellID>
Physical Cell ID
<earfcn>
E-UTRA absolute radio frequency channel number for searching LTE cells
<dlbw>
Transmission bandwidth configuration of the serving cell on the downlink
<ulbw>
Transmission bandwidth configuration of the serving cell on the uplink
<RSRP>
Current reference signal received power in -1/10 dBm. Available for LTE
<RSRQ>
Current reference signal receive quality as measured by L1.
<RSSNR>
Average reference signal signal-to-noise ratio of the serving cell
<BID>
Base ID
lF
ile
Smart Machine Smart Decision
C
om
AT+CPSI?
+CPSI: WCDMA,Online,460-01,0xA809,11122855,WCDMA IMT 2000,279,10663,0,1.5,62,33,
52,500
OK
AT+CPSI=?
+CPSI: (0-255)
OK
5.15
AT+CNSMOD Show network system mode
Description
SI
M
This command is used to return the current network system mode.
SIM PIN
NO
References
Vendor
Syntax
SIM7906_SIM7912 Series_AT Command Manual_V1.01
74
2019-11-21
Smart Machine Smart Decision
Test Command
AT+CNSMOD=?
Responses
+CNSMOD: (list of supported <n>s)
Read Command
AT+CNSMOD?
lF
ile
OK
Responses
+CNSMOD: <n>,<stat>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ia
Write Command
AT+CNSMOD=<n>
+CME ERROR: <err>
id
e
Defined values
<n>
– disable auto report the network system mode information
– auto report the network system mode information, command: +CNSMOD:<stat>
–
–
–
–
–
–
C
on
f
0
1
<stat>
0
4
5
6
7
8
nt
ERROR
no service
WCDMA
HSDPA only(WCDMA)
HSUPA only(WCDMA)
HSPA (HSDPA and HSUPA, WCDMA)
LTE
C
om
Examples
AT+CNSMOD?
+CNSMOD: 0,8
OK
AT+CEREG EPS network registration status
M
5.16
SI
Description
The set command controls the presentation of an unsolicited result code +CEREG: <stat> when
<n>=1 and there is a change in the MT's EPS network registration status in E-UTRAN, or
unsolicited result code +CEREG: <stat>[,<tac>,<ci>[,<AcT>]] when <n>=2 and there is a change
of the network cell in E-UTRAN; in this latest case <AcT>, <tac> and <ci> are sent only if
available.
NOTE 1: If the EPS MT in GERAN/UTRAN/E-UTRAN also supports circuit mode services and/or
SIM7906_SIM7912 Series_AT Command Manual_V1.01
75
2019-11-21
Smart Machine Smart Decision
NO
References
3GPP TS 24.008 [8]
Syntax
ERROR
Read Command
AT+CEREG?
nt
Responses
+CEREG: (list of supported <n>s)
OK
id
e
Test Command
AT+CEREG=?
ia
SIM PIN
lF
ile
GPRS services, the +CREG command and +CREG: result codes and/or the +CGREG command
and +CGREG: result codes apply to the registration status and location information for those
services.
The read command returns the status of result code presentation and an integer <stat> which shows
whether the network has currently indicated the registration of the MT. Location information
elements <tac>, <ci> and <AcT>, if available, are returned only when <n>=2 and MT is registered
in the network.
Responses
+CEREG: <n>,<stat>[,<tac>,<ci>[,<AcT>]]
OK
C
on
f
ERROR
Write Command
AT+CEREG=[<n>]
Responses
OK
ERROR
+CME ERROR: <err>
C
om
Execution Command
AT+CEREG
Responses
Set default value(<n>=0):
OK
ERROR
Defined values
<n>
SI
M
0 – disable network registration unsolicited result code
1 – enable network registration unsolicited result code +CEREG: <stat>
2 – enable network registration and location information unsolicited result code
+CEREG: <stat>[,<tac>,<ci>[,<AcT>]]
<stat>
0 – not registered, MT is not currently searching an operator to register to
1 – registered, home network
2 – not registered, but MT is currently trying to attach or searching an operator to register to
3 – registration denied
SIM7906_SIM7912 Series_AT Command Manual_V1.01
76
2019-11-21
Smart Machine Smart Decision
string type; four byte E-UTRAN cell identify in hexadecimal format
id
e
nt
ia
<AcT>
A numberic parameter that indicates the access technology of serving cell
2 UTRAN (not applicable)
4 UTRAN w/HSDPA (see NOTE 4) (not applicable)
5 UTRAN w/HSUPA (see NOTE 4) (not applicable)
6 UTRAN w/HSDPA and HSUPA (see NOTE 4) (not applicable)
7 E-UTRAN
lF
ile
4 – unknown (e.g. out of E-UTRAN coverage)
5 – registered, roaming
6 – registered for "SMS only", home network (not applicable)
7 – registered for "SMS only", roaming (not applicable)
8 – attached for emergency bearer services only (See NOTE 2)
<tac>
string type; two byte tracking area code in hexadecimal format (e.g. "00C3" equals 195 in decimal)
<ci>
AT+CEREG?
+CEREG: 0,4
OK
5.17
C
on
f
Examples
AT+CTZU Automatic time and time zone update
Description
C
om
This command is used to enable and disable automatic time and time zone update via NITZ
SIM PIN
YES
References
3GPP TS 27.007
SI
M
Syntax
Test Command
AT+CTZU=?
Responses
+CTZU: (list of supported <on/off>s)
OK
Read Command
AT+CTZU?
Responses
+CTZU: < on/off >
OK
Write Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
77
2019-11-21
Smart Machine Smart Decision
AT+CTZU=< on/off >
OK
ERROR
lF
ile
Defined values
id
e
nt
ia
<on/off>
Integer type value indicating:
0 – Disable automatic time zone update via NITZ (default).
1 – Enable automatic time zone update via NITZ.
NOTE: 1. The value of < on/off > is nonvolatile, and factory value is 0.
2. For automatic time and time zone update is enabled (+CTZU=1):
If time zone is only received from network and it isn’t equal to local time zone
(AT+CCLK), time zone is updated automatically, and real time clock is updated based
on local time and the difference between time zone from network and local time zone
(Local time zone must be valid).
If Universal Time and time zone are received from network, both time zone and real
time clock is updated automatically, and real time clock is based on Universal Time and
time zone from network.
AT+CTZU?
+CTZU: 0
OK
AT+CTZU=1
OK
AT+CTZR Time and time zone reporting
C
om
5.18
C
on
f
Examples
Description
SI
M
This command is used to enable and disable the time zone change event reporting. If the reporting
is enabled the MT returns the unsolicited result code +CTZV: <tz>[,<time>][,<dst>]whenever the
time zone is changed.
NOTE: The time zone reporting is not affected by the Automatic Time and Time Zone command
AT+CTZU.
SIM PIN
YES
References
3GPP TS 27.007
SIM7906_SIM7912 Series_AT Command Manual_V1.01
78
2019-11-21
Smart Machine Smart Decision
Responses
+CTZR: (list of supported < on/off >s)
OK
Read Command
AT+CTZR?
Responses
+CTZR: < on/off >
OK
Write Command
AT+CTZR=< on/off >
Responses
OK
ia
Test Command
AT+CTZR=?
id
e
Responses
Set default value:
OK
nt
ERROR
Execution Command
AT+CTZR
lF
ile
Syntax
Defined values
C
om
C
on
f
<on/off>
Integer type value indicating:
0 – Disable time zone change event reporting (default).
1 – Enable time zone change event reporting.
+CTZV: <tz>[,<time>][,<dst>]
Unsolicited result code when time zone received from network isn’t equal to local time zone, and if
the informations from network don’t include date and time, time zone will be only reported, and if
network daylight saving time is present, it is also reported. For example:
+CTZV: 32 (Only report time zone)
+CTZV: 32,1 (Report time zone and network daylight saving time)
+CTZV: 32,08/12/09,17:00:00 (Report time and time zone)
+CTZV: 32,08/12/09,17:00:00,1 (Report time, time zone and daylight saving time)
SI
M
For more detailed informations about time and time zone, please refer 3GPP TS 24.008.
<tz>
Local time zone received from network.
<time> Universal time received from network, and the format is “yy/MM/dd,hh:mm:ss”,
where characters indicate year (two last digits), month, day, hour, minutes and
seconds.
<dst> Network daylight saving time, and if it is received from network, it indicates the
value that has been used to adjust the local time zone. The values as following:
0 – No adjustment for Daylight Saving Time.
1 – +1 hour adjustment for Daylight Saving Time.
2 – +2 hours adjustment for Daylight Saving Time.
NOTE: Herein, <time> is Universal Time or NITZ time, but not local time.
Examples
SIM7906_SIM7912 Series_AT Command Manual_V1.01
79
2019-11-21
Smart Machine Smart Decision
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
AT+CTZR?
+CTZR: 0
OK
AT+CTZR=1
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
80
2019-11-21
Smart Machine Smart Decision
6.1
AT Commands for SMS
lF
ile
6
AT+CSMS Select message service
Description
This command is used to select messaging service <service>.
ia
YES
References
3GPP TS 27.005
nt
SIM PIN
Syntax
Responses
+CSMS: (list of supported <service>s)
OK
Read Command
AT+CSMS?
Responses
+CSMS: <service>,<mt>,<mo>,<bm>
OK
C
on
f
id
e
Test Command
AT+CSMS=?
Write Command
AT+CSMS=<service>
Responses
+CSMS: <mt>,<mo>,<bm>
OK
ERROR
C
om
+CMS ERROR: <err>
Defined values
SI
M
<service>
0 – SMS at command is compatible with GSM phase 2.
1 – SMS at command is compatible with GSM phase 2+.
<mt>
Mobile terminated messages:
0 – type not supported.
1 – type supported.
<mo>
Mobile originated messages:
0 – type not supported.
1 – type supported.
<bm>
Broadcast type messages:
SIM7906_SIM7912 Series_AT Command Manual_V1.01
81
2019-11-21
Smart Machine Smart Decision
0
1
–
–
type not supported.
type supported.
lF
ile
Examples
Preferred message storage
nt
AT+CPMS
id
e
6.2
ia
AT+CSMS=0
+CSMS:1,1,1
OK
AT+CSMS?
+CSMS:0,1,1,1
OK
AT+CSMS=?
+CSMS:(0-1)
OK
Description
SIM PIN
YES
C
on
f
This command is used to select memory storages <mem1>, <mem2> and <mem3> to be used for
reading, writing, etc.
References
3GPP TS 27.005
C
om
Syntax
Responses
+CPMS: (list of supported <mem1>s), (list of supported
<mem2>s), (list of supported <mem3>s)
OK
Read Command
AT+CPMS?
Responses
+CPMS:<mem1>,<used1>,<total1>,<mem2>,<used2>,<total2>,
SI
M
Test Command
AT+CPMS=?
<mem3>,<used3>,<total3>
OK
ERROR
+CMS ERROR: <err>
Write Command
AT+CPMS=<mem1>
[,<mem2>[,<mem3>]]
Responses
+CPMS: <used1>,<total1>,<used2>,<total2>,<used3>,<total3>
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
82
2019-11-21
Smart Machine Smart Decision
ERROR
+CMS ERROR: <err>
Responses
Set
default
value
(<mem1>=”SM”,
<mem2>=”SM”,
<mem3>=”SM”):
+CPMS: <used1>,<total1>,<used2>,<total2>,<used3>,<total3>
lF
ile
Execution Command
AT+CPMS
OK
ERROR
ia
Defined values
C
om
C
on
f
id
e
nt
<mem1>
String type, memory from which messages are read and deleted (commands List Messages
AT+CMGL, Read Message AT+CMGR and Delete Message AT+CMGD).
“ME” and “MT”
FLASH message storage
“SM”
SIM message storage
“SR”
Status report storage
<mem2>
String type, memory to which writing and sending operations are made (commands Send Message
from Storage AT+CMSS and Write Message to Memory AT+CMGW).
“ME” and “MT”
FLASH message storage
“SM”
SIM message storage
“SR”
Status report storage
<mem3>
String type, memory to which received SMS is preferred to be stored (unless forwarded directly to
TE; refer command New Message Indications AT+CNMI).
“ME”
FLASH message storage
“SM”
SIM message storage
<usedX>
Integer type, number of messages currently in <memX>.
<totalX>
Integer type, total number of message locations in <memX>.
SI
M
Examples
AT+CPMS=?
+CPMS: ("ME","MT","SM","SR"),("ME","MT","SM","SR"),("ME","SM")
OK
AT+CPMS?
+CPMS:"ME", 0, 23,"ME", 0, 23,"ME", 0, 23
OK
AT+CPMS="SM","SM","SM"
+CPMS:3,50,3,50,3,50
SIM7906_SIM7912 Series_AT Command Manual_V1.01
83
2019-11-21
Smart Machine Smart Decision
OK
AT+CMGF Select SMS message format
lF
ile
6.3
Description
This command is used to specify the input and output format of the short messages.
YES
References
3GPP TS 27.005
Syntax
Responses
+CMGF: (list of supported <mode>s)
nt
Test Command
AT+CMGF=?
Read Command
AT+CMGF?
id
e
OK
ERROR
ia
SIM PIN
Responses
+CMGF: <mode>
C
on
f
OK
ERROR
Write Command
AT+CMGF=<mode>
Responses
OK
ERROR
C
om
Execution Command
AT+CMGF
Responses
Set default value (<mode>=0):
OK
ERROR
Defined values
M
<mode>
0 – PDU mode
1 – Text mode
SI
Examples
AT+CMGF?
+CMGF: 0
OK
AT+CMGF=?
+CMGF: (0-1)
SIM7906_SIM7912 Series_AT Command Manual_V1.01
84
2019-11-21
Smart Machine Smart Decision
6.4
lF
ile
OK
AT+CMGF=1
OK
AT+CSCA SMS service centre address
Description
YES
References
3GPP TS 27.005
nt
SIM PIN
ia
This command is used to update the SMSC address, through which mobile originated SMS are
transmitted.
Syntax
Responses
AT+CSCA=?
OK
Read Command
Responses
AT+CSCA?
+CSCA: <sca>,<tosca>
C
on
f
id
e
Test Command
OK
Write Command
AT+CSCA=<sca>[,<tosca>]
Defined values
Responses
OK
C
om
<sca>
Service Centre Address, value field in string format, BCD numbers (or GSM 7 bit default alphabet
characters) are converted to characters of the currently selected TE character set (refer to command
AT+CSCS), type of address given by <tosca>.
<tosca>
SC address Type-of-Address octet in integer format, when first character of <sca> is + (IRA 43)
default is 145, otherwise default is 129.
SI
M
Examples
AT+CSCA="+8613012345678"
OK
AT+CSCA?
+CSCA: "+8613010314500", 145
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
85
2019-11-21
Smart Machine Smart Decision
6.5
AT+CSCB
Select cell broadcast message indication
lF
ile
Description
The test command returns the supported <mode>s as a compound value.
The read command displays the accepted message types.
Depending on the <mode> parameter, the write command adds or deletes the message types
accepted.
YES
References
3GPP TS 27.005
ia
SIM PIN
nt
Syntax
Responses
AT+CSCB=?
+CSCB: (list of supported <mode>s)
OK
ERROR
id
e
Test Command
Read Command
Responses
AT+CSCB?
+CSCB: <mode>,<mids>,<dcss>
C
on
f
OK
ERROR
Write Command
AT+CSCB=<mode>[,<mids
>[,<dcss>]]
Responses
OK
ERROR
C
om
+CMS ERROR: <err>
Defined values
SI
M
<mode>
0 – message types specified in <mids> and <dcss> are accepted.
1 – message types specified in <mids> and <dcss> are not accepted.
<mids>
String type; all different possible combinations of CBM message identifiers.
<dcss>
String type; all different possible combinations of CBM data coding schemes(default is empty
string)
Examples
AT+CSCB=?
+CSCB: (0-1)
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
86
2019-11-21
Smart Machine Smart Decision
AT+CSCB=0,”15-17,50,86”,””
OK
AT+CSMP Set text mode parameters
lF
ile
6.6
Description
This command is used to select values for additional parameters needed when SM is sent to the
network or placed in storage when text format message mode is selected.
YES
References
3GPP TS 27.005
ia
SIM PIN
nt
Syntax
Responses
AT+CSMP=?
OK
Read Command
Responses
AT+CSMP?
+CSMP: <fo>,<vp>,<pid>,<dcs>
OK
AT+CSMP=[<fo>[,<vp>[,<p
id>[,<dcs>]]]]
Defined values
Responses
C
on
f
Write Command
id
e
Test Command
OK
SI
M
C
om
<fo>
Depending on the Command or result code: first octet of GSM 03.40 SMS-DELIVER,
SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer
format. SMS status report is supported under text mode if <fo> is set to 49.
<vp>
Depending on SMS-SUBMIT <fo> setting: GSM 03.40,TP-Validity-Period either in integer format
(default 167), in time-string format, or if is supported, in enhanced format (hexadecimal coded
string with quotes), (<vp> is in range 0... 255).
<pid>
GSM 03.40 TP-Protocol-Identifier in integer format (default 0).
<dcs>
GSM 03.38 SMS Data Coding Scheme (default 0), or Cell Broadcast Data Coding Scheme in
integer format depending on the command or result code.
Examples
AT+CSMP=17,23,64,244
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
87
2019-11-21
Smart Machine Smart Decision
6.7
AT+CSDH
Show text mode parameters
lF
ile
Description
This command is used to control whether detailed header information is shown in text mode result
codes.
SIM PIN
YES
References
3GPP TS 27.005
ia
Syntax
Responses
AT+CSDH=?
+CSDH: (list of supported <show>s)
nt
Test Command
ERROR
id
e
OK
Read Command
Responses
AT+CSDH?
+CSDH: <show>
OK
Responses
C
on
f
Write Command
AT+CSDH=<show>
OK
ERROR
Execution Command
Responses
AT+CSDH
Set default value (<show>=0):
OK
C
om
ERROR
Defined values
SI
M
<show>
0 – do not show header values defined in commands AT+CSCA and AT+CSMP (<sca>,
<tosca>, <fo>, <vp>, <pid> and <dcs>) nor <length>, <toda> or <tooa> in +CMT,
AT+CMGL, AT+CMGR result codes for SMS-DELIVERs and SMS-SUBMITs in text
mode; for SMS-COMMANDs in AT+CMGR result code, do not show <pid>, <mn>,
<da>, <toda>, <length> or <data>
1 – show the values in result codes
Examples
AT+CSDH?
+CSDH: 0
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
88
2019-11-21
Smart Machine Smart Decision
AT+CSDH=1
OK
AT+CNMA New message acknowledgement to ME/TA
lF
ile
6.8
Description
YES
References
id
e
SIM PIN
nt
ia
This command is used to confirm successful receipt of a new message (SMS-DELIVER or
SMS-STATUSREPORT) routed directly to the TE. If ME does not receive acknowledgement within
required time (network timeout), it will send RP-ERROR to the network.
NOTE: The execute / write command shall only be used when AT+CSMS parameter <service>
equals 1 (= phase 2+) and appropriate URC has been issued by the module, i.e.:
<+CMT> for <mt>=2 incoming message classes 0, 1, 3 and none;
<+CMT> for <mt>=3 incoming message classes 0 and 3;
<+CDS> for <ds>=1.
3GPP TS 27.005
Test Command
AT+CNMA=?
C
on
f
Syntax
Responses
if text mode(AT+CMGF=1):
OK
if PDU mode (AT+CMGF=0):
+CNMA: (list of supported <n>s)
OK
Write Command
C
om
AT+CNMA=<n>
Responses
OK
ERROR
+CMS ERROR: <err>
Responses
AT+CNMA
OK
M
Execution Command
ERROR
+CMS ERROR: <err>
SI
Defined values
<n>
Parameter required only for PDU mode.
0 – Command operates similarly as execution command in text mode.
1 – Send positive (RP-ACK) acknowledgement to the network. Accepted only in PDU
mode.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
89
2019-11-21
Smart Machine Smart Decision
2
–
Send negative (RP-ERROR) acknowledgement to the network. Accepted only in PDU
mode.
6.9
ia
id
e
nt
AT+CNMI=1,2,0,0,0
OK
+CMT:”1380022xxxx”,””,”02/04/03,11 :06 :38+32”<CR><LF>
Testing
(receive new short message)
AT+CNMA(send ACK to the network)
OK
AT+CNMA
+CMS ERROR:340
(the second time return error, it needs ACK only once)
lF
ile
Examples
AT+CNMI
New message indications to TE
Description
SIM PIN
YES
C
on
f
This command is used to select the procedure how receiving of new messages from the network is
indicated to the TE when TE is active, e.g. DTR signal is ON. If TE is inactive (e.g. DTR signal is
OFF). If set <mt>=3 or <ds>=1, make sure <mode>=1, If set <mt>=2,make sure <mode>=1 or
2, otherwise it will return error.
References
3GPP TS 27.005
C
om
Syntax
Test Command
Responses
AT+CNMI=?
+CNMI: (list of supported <mode>s),(list of supported <mt>s),(list
of supported <bm>s),(list of supported <ds>s),(list of supported
<bfr>s)
M
Read Command
SI
AT+CNMI?
OK
Responses
+CNMI: <mode>,<mt>,<bm>,<ds>,<bfr>
OK
Write Command
Responses
AT+CNMI=<mode>[,<mt>[,
<bm>[,<ds> [,<bfr>]]]]
OK
ERROR
+CMS ERROR: <err>
Execution Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
90
2019-11-21
Smart Machine Smart Decision
Set default value:
OK
lF
ile
AT+CNMI
Defined values
–
2
–
nt
1
Buffer unsolicited result codes in the TA. If TA result code buffer is full, indications
can be buffered in some other place or the oldest indications may be discarded and
replaced with the new received indications.
Discard indication and reject new received message unsolicited result codes when
TA-TE link is reserved (e.g. in on-line data mode). Otherwise forward them directly
to the TE.
Buffer unsolicited result codes in the TA when TA-TE link is reserved (e.g. in on-line
data mode) and flush them to the TE after reservation. Otherwise forward them
directly to the TE.
ia
<mode>
0
–
SI
M
C
om
C
on
f
id
e
<mt>
The rules for storing received SMS depend on its data coding scheme, preferred memory storage
(AT+CPMS) setting and this value:
0
– No SMS-DELIVER indications are routed to the TE.
1
– If SMS-DELIVER is stored into ME/TA, indication of the memory location is routed
to the TE using unsolicited result code: +CMTI: <mem3>,<index>.
2
– SMS-DELIVERs (except class 2 messages and messages in the message waiting
indication group (store message)) are routed directly to the TE using unsolicited
result code:
+CMT:[<alpha>],<length><CR><LF><pdu> (PDU mode enabled); or
+CMT:<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>,<sca>,<tosca>,<length>]
<CR> <LF><data>
(text mode enabled, about parameters in italics, refer command Show Text Mode
Parameters AT+CSDH).
3
– Class 3 SMS-DELIVERs are routed directly to TE using unsolicited result codes
defined in <mt>=2. Messages of other data coding schemes result in indication as
defined in <mt>=1.
<bm>
The rules for storing received CBMs depend on its data coding scheme, the setting of Select CBM
Types (AT+CSCB) and this value:
0 – No CBM indications are routed to the TE.
2 – New CBMs are routed directly to the TE using unsolicited result code:
+CBM: <length><CR><LF><pdu> (PDU mode enabled); or
+CBM: <sn>,<mid>,<dcs>,<page>,<pages><CR><LF><data> (text mode enabled)
<ds>
0 – No SMS-STATUS-REPORTs are routed to the TE.
1 – SMS-STATUS-REPORTs are routed to the TE using unsolicited result code:
+CDS: <length><CR><LF><pdu> (PDU mode enabled); or
SIM7906_SIM7912 Series_AT Command Manual_V1.01
91
2019-11-21
Smart Machine Smart Decision
2
+CDS: <fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st> (text mode enabled)
– If SMS-STATUS-REPORT is stored into ME/TA, indication of the memory location is
routed to the TE using unsolicited result code: +CDSI: <mem3>,<index>.
lF
ile
<bfr>
0
– TA buffer of unsolicited result codes defined within this command is flushed to the TE
when <mode> 1 to 3 is entered (OK response shall be given before flushing the codes).
1 – TA buffer of unsolicited result codes defined within this command is cleared when
<mode> 1 to 3 is entered.
AT+CGSMS
Select service for MO SMS messages
C
on
f
6.10
id
e
nt
AT+CNMI?
+CNMI: 0,0,0,0,0
OK
AT+CNMI=?
+CNMI: (0,1,2),(0,1,2,3),(0,2),(0,1,2),(0,1)
OK
AT+CNMI=2,1 (unsolicited result codes after received messages.)
OK
ia
Examples
Description
C
om
The write command is used to specify the service or service preference that the MT will use to send
MO SMS messages.
The test command is used for requesting information on which services and service preferences can
be set by using the AT+CGSMS write command
The read command returns the currently selected service or service preference.
SIM PIN
YES
References
3GPP TS 27.007
Syntax
M
Test Command
SI
AT+CGSMS=?
Responses
+CGSMS: (list of supported <service>s)
OK
Read Command
Responses
AT+CGSMS?
+CGSMS: <service>
OK
Write Command
Responses
AT+CGSMS=<service>
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
92
2019-11-21
Smart Machine Smart Decision
ERROR
lF
ile
+CME ERROR: <err>
Defined values
ia
<service>
A numeric parameter which indicates the service or service preference to be used
0 – GPRS(value is not really supported and is internally mapped to 2)
1 – circuit switched(value is not really supported and is internally mapped to 3)
2 – GPRS preferred (use circuit switched if GPRS not available)
3 – circuit switched preferred (use GPRS if circuit switched not available)
nt
Examples
C
on
f
6.11
id
e
AT+CGSMS?
+CGSMS: 3
OK
AT+CGSMS=?
+CGSMS: (0-3)
OK
AT+CMGL List SMS messages from preferred storeDescription
This command is used to return messages with status value <stat> from message storage <mem1>
to the TE.
If the status of the message is 'received unread', the status in the storage changes to 'received read'.
SIM PIN
3GPP TS 27.005
C
om
YES
References
Syntax
SI
M
Test Command
AT+CMGL=?
Responses
+CMGL: (list of supported <stat>s)
OK
Write Command
Responses
AT+CMGL=<stat>
If text mode (AT+CMGF=1), command successful and SMS-S
UBMITs and/or SMS-DELIVERs:
+CMGL:<index>,<stat>,<oa>/<da>,[<alpha>],[<scts>][,<tooa>/<t
oda>,<fo>,<pid>,<dcs>,<sca>,<tosca>,<length>]<CR><LF><data
>[<CR><LF>
+CMGL:<index>,<stat>,<oa>/<da>,[<alpha>],[<scts>][,<tooa>/<t
oda>,<fo>,<pid>,<dcs>,<sca>,<tosca>,<length>]<CR><LF><data
SIM7906_SIM7912 Series_AT Command Manual_V1.01
93
2019-11-21
Smart Machine Smart Decision
>[...]]
OK
lF
ile
If text mode (AT+CMGF=1), command successful and SMSSTATUS-REPORTs:
+CMGL:<index>,<stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<s
t>[<CR><LF>
+CMGL:<index>,<stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<s
t>[...]]
OK
ia
If text mode (AT+CMGF=1), command successful and SMSCOMMANDs:
+CMGL: <index>,<stat>,<fo>,<ct>[<CR><LF>
nt
+CMGL: <index>,<stat>,<fo>,<ct>[...]]
OK
id
e
If text mode (AT+CMGF=1), command successful and CBM
storage:
+CMGL:<index>,<stat>,<sn>,<mid>,<page>,<pages>
<CR><LF><data>[<CR><LF>
C
on
f
+CMGL:<index>,<stat>,<sn>,<mid>,<page>,<pages>
<CR><LF><data>[...]]
OK
If PDU mode (AT+CMGF=0) and Command successful:
+CMGL:<index>,<stat>,[<alpha>],<length><CR><LF><pdu>[<C
R><LF>
+CMGL:<index>,<stat>,[<alpha>],<length><CR><LF><pdu>
C
om
[…]]
OK
+CMS ERROR: <err>
Defined values
SI
M
<stat>
1. Text Mode:
"REC UNREAD" received unread message (i.e. new message)
"REC READ"
received read message
"STO UNSENT" stored unsent message
"STO SENT"
stored sent message
"ALL"
all messages
2. PDU Mode:
0 – received unread message (i.e. new message)
1 – received read message
2 – stored unsent message
SIM7906_SIM7912 Series_AT Command Manual_V1.01
94
2019-11-21
Smart Machine Smart Decision
3
4
– stored sent message
– all messages
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <tooa>.
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<alpha>
String type alphanumeric representation of <da> or <oa> corresponding to the entry found in MT
phonebook; implementation of this feature is manufacturer specific; used character set should be
the one selected with command Select TE Character Set AT+CSCS.
<scts>
TP-Service-Centre-Time-Stamp in time-string format (refer <dt>).
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda>).
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length>
Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body
<data> in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP data unit in
octets. (i.e. the RP layer SMSC address octets are not counted in the length)
<data>
In the case of SMS: TP-User-Data in text mode responses; format:
1. If <dcs> indicates that GSM 7 bit default alphabet is used and <fo> indicates that
TP-User-Data-Header-Indication is not set:
a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current TE
character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit character of GSM 7 bit
default alphabet into two IRA character long hexadecimal numbers. (e.g. character Π
(GSM 7 bit default alphabet 23) is presented as 17 (IRA 49 and 55))
2. If <dcs> indicates that 8-bit or UCS2 data coding scheme is used, or <fo> indicates that
TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA
character long hexadecimal numbers. (e.g. octet with integer value 42 is presented to TE as
two characters 2A (IRA 50 and 65))
3. If <dcs> indicates that GSM 7 bit default alphabet is used:
a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current TE
SIM7906_SIM7912 Series_AT Command Manual_V1.01
95
2019-11-21
Smart Machine Smart Decision
lF
ile
character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7 bit
default alphabet into two IRA character long hexadecimal numbers.
4. If <dcs> indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each
8-bit octet into two IRA character long hexadecimal numbers.
SI
M
C
om
C
on
f
id
e
nt
ia
<fo>
Depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER,
SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer
format. SMS status report is supported under text mode if <fo> is set to 49.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<ra>
Recipient Address
GSM 03.40 TP-Recipient-Address Address-Value field in string format;BCD numbers (or GSM
default alphabet characters) are converted to characters of the currently selected TE character
set(refer to command AT+CSCS);type of address given by <tora>
<tora>
Type of Recipient Address
GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda>)
<dt>
Discharge Time
GSM 03.40 TP-Discharge-Time in time-string format:”yy/MM/dd,hh:mm:ss+zz”,where characters
indicate year (two last digits),month,day,hour,minutes,seconds and time zone.
<st>
Status
GSM 03.40 TP-Status in integer format
0…255
<ct>
Command Type
GSM 03.40 TP-Command-Type in integer format
0…255
<sn>
Serial Number
GSM 03.41 CBM Serial Number in integer format
<mid>
Message Identifier
GSM 03.41 CBM Message Identifier in integer format
<page>
Page Parameter
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
<pages>
Page Parameter
SIM7906_SIM7912 Series_AT Command Manual_V1.01
96
2019-11-21
Smart Machine Smart Decision
lF
ile
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
<pdu>
In the case of SMS: SC address followed by TPDU in hexadecimal format: ME/TA converts each
octet of TP data unit into two IRA character long hexadecimal numbers. (e.g. octet with integer
value 42 is presented to TE as two characters 2A (IRA 50 and 65)).
Examples
6.12
AT+CMGR Read message
Description
id
e
nt
ia
AT+CMGL=?
+CMGL: ("REC UNREAD","REC READ","STO UNSENT","STO SENT","ALL")
OK
AT+CMGL="ALL"
+CMGL: 1,"STO UNSENT","+10011",,,145,4
Hello World
OK
SIM PIN
YES
C
on
f
This command is used to return message with location value <index> from message storage
<mem1> to the TE.
References
3GPP TS 27.005
Syntax
Responses
OK
Write Command
AT+CMGR=<index>
Responses
If text mode (AT+CMGF=1), command successful and SMSDELIVER:
+CMGR: <stat>,<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>,
<sca>, <tosca>, <length>]<CR><LF><data>
SI
M
C
om
Test Command
AT+CMGR=?
OK
If text mode (AT+CMGF=1), command successful and SMSSUBMIT:
+CMGR:<stat>,<da>,[<alpha>][,<toda>,<fo>,<pid>,<dcs>,[<vp>],
<sca>, <tosca>,<length>]<CR><LF><data>
OK
If text mode (AT+CMGF=1), command successful and SMSSTATUS-REPORT:
SIM7906_SIM7912 Series_AT Command Manual_V1.01
97
2019-11-21
Smart Machine Smart Decision
+CMGR: <stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st>
OK
lF
ile
If text mode (AT+CMGF=1), command successful and SMSCOMMAND:
+CMGR:<stat>,<fo>,<ct>[,<pid>,[<mn>],[<da>],[<toda>],<length
>]<CR><LF><data>
OK
ia
If text mode (AT+CMGF=1), command successful and CBM
storage:
+CMGR:<stat>,<sn>,<mid>,<dcs>,<page>,<pages><CR><LF><d
ata>
OK
id
e
nt
If PDU mode (AT+CMGF=0) and Command successful:
+CMGR:<stat>,[<alpha>],<length><CR><LF><pdu>
OK
+CMS ERROR: <err>
Defined values
SI
M
C
om
C
on
f
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<stat>
1.Text Mode:
"REC UNREAD" received unread message (i.e. new message)
"REC READ"
received read message
"STO UNSENT" stored unsent message
"STO SENT"
stored sent message
2. PDU Mode:
0 – received unread message (i.e. new message)
1 – received read message.
2 – stored unsent message.
3 – stored sent message
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <tooa>.
<alpha>
String type alphanumeric representation of <da> or <oa> corresponding to the entry found in MT
phonebook; implementation of this feature is manufacturer specific; used character set should be
the one selected with command Select TE Character Set AT+CSCS.
<scts>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
98
2019-11-21
Smart Machine Smart Decision
C
om
C
on
f
id
e
nt
ia
lF
ile
TP-Service-Centre-Time-Stamp in time-string format (refer <dt>).
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda>).
<fo>
Depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER,
SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer
format. SMS status report is supported under text mode if <fo> is set to 49.
<pid>
Protocol Identifier
GSM 03.40 TP-Protocol-Identifier in integer format
0…255
<dcs>
Depending on the command or result code: SMS Data Coding Scheme (default 0), or Cell
Broadcast Data Coding Scheme in integer format.
<sca>
RP SC address Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet
characters) are converted to characters of the currently selected TE character set, type of address
given by <tosca>.
<tosca>
RP SC address Type-of-Address octet in integer format (default refer <toda>).
<length>
Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP
data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length).
<data>
In the case of SMS: TP-User-Data in text mode responses; format:
1 – If <dcs> indicates that GSM 7 bit default alphabet is used and <fo> indicates that
TP-User-Data-Header-Indication is not set:
a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current
TE character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit character of GSM 7 bit
default alphabet into two IRA character long hexadecimal numbers. (e.g. character
SI
M
2
3
4
Π (GSM 7 bit default alphabet 23) is presented as 17 (IRA 49 and 55)).
– If <dcs> indicates that 8-bit or UCS2 data coding scheme is used, or <fo> indicates that
TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA
character long hexadecimal numbers. (eg. octet with integer value 42 is presented to TE
as two characters 2A (IRA 50 and 65)).
– If <dcs> indicates that GSM 7 bit default alphabet is used:
a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current
TE character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7
bit default alphabet into two IRA character long hexadecimal numbers.
– If <dcs> indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts
SIM7906_SIM7912 Series_AT Command Manual_V1.01
99
2019-11-21
Smart Machine Smart Decision
each 8-bit octet into two IRA character long hexadecimal numbers.
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<vp>
Depending on SMS-SUBMIT <fo> setting: TP-Validity-Period either in integer format (default
167) or in time-string format (refer <dt>).
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<ra>
Recipient Address
GSM 03.40 TP-Recipient-Address Address-Value field in string format;BCD numbers(or GSM
default alphabet characters) are converted to characters of the currently selected TE character
set(refer to command AT+CSCS);type of address given by <tora>
<tora>
Type of Recipient Address
GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda>)
<dt>
Discharge Time
GSM 03.40 TP-Discharge-Time in time-string format:”yy/MM/dd,hh:mm:ss+zz”,where characters
indicate year (two last digits),month,day,hour,minutes,seconds and time zone.
<st>
Status
GSM 03.40 TP-Status in integer format
0…255
<ct>
Command Type
GSM 03.40 TP-Command-Type in integer format
0…255
<mn>
Message Number
GSM 03.40 TP-Message-Number in integer format
<sn>
Serial Number
GSM 03.41 CBM Serial Number in integer format
<mid>
Message Identifier
GSM 03.41 CBM Message Identifier in integer format
SIM7906_SIM7912 Series_AT Command Manual_V1.01
100
2019-11-21
Smart Machine Smart Decision
ia
lF
ile
<page>
Page Parameter
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
<pages>
Page parameter
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
<pdu>
In the case of SMS: SC address followed by TPDU in hexadecimal format: ME/TA converts each
octet of TP data unit into two IRA character long hexadecimal numbers. (eg. octet with integer
value 42 is presented to TE as two characters 2A (IRA 50 and 65)).
Examples
AT+CMGS Send message
Description
C
on
f
6.13
id
e
nt
AT+CMGR=1
+CMGR: "STO UNSENT","+10011",,145,17,0,0,167,"+8613800100500",145,11
Hello World
OK
This command is used to send message from a TE to the network (SMS-SUBMIT).
SIM PIN
YES
References
3GPP TS 27.005
C
om
Syntax
Responses
OK
Write Command
If text mode (AT+CMGF=1):
AT+CMGS=<da>[,<toda>]<
CR>Text is entered.
<CTRL-Z/ESC>
If PDU mode(AT+CMGF=
0):
AT+CMGS=<length><CR>
PDU is entered
<CTRL-Z/ESC>
Responses
If sending successfully:
SI
M
Test Command
AT+CMGS=?
+CMGS: <mr>
OK
If cancel sending:
OK
If sending fails:
ERROR
If sending fails:
+CMS ERROR: <err>
Defined values
SIM7906_SIM7912 Series_AT Command Manual_V1.01
101
2019-11-21
Smart Machine Smart Decision
id
e
nt
ia
lF
ile
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length>
integer type value indicating in the text mode (AT+CMGF=1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP
data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length)
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
6.14
AT+CMSS
Description
C
on
f
AT+CMGS="13012832788"<CR>(TEXT MODE)
> ABCD<ctrl-Z/ESC>
+CMGS: 46
OK
Send message from storage
C
om
This command is used to send message with location value <index> from preferred message
storage <mem2> to the network (SMS-SUBMIT or SMS-COMMAND).
SIM PIN
YES
References
3GPP TS 27.005
SI
M
Syntax
Test Command
Responses
AT+CMSS=?
OK
Write Command
Responses
AT+CMSS=
<index> [,<da>[,<toda>]]
+CMSS: <mr>
OK
ERROR
If sending fails:
SIM7906_SIM7912 Series_AT Command Manual_V1.01
102
2019-11-21
Smart Machine Smart Decision
+CMS ERROR: <err>
lF
ile
Defined values
id
e
nt
ia
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
C
on
f
Examples
C
om
AT+CMSS=3
+CMSS: 0
OK
AT+CMSS=3,"13012345678"
+CMSS: 55
OK
6.15
AT+CMGW Write message to memory
Description
M
This command is used to store message (either SMS-DELIVER or SMS-SUBMIT) to memory
storage <mem2>.
SIM PIN
SI
YES
References
3GPP TS 27.005
Syntax
Test Command
AT+CMGW=?
Responses
OK
Write Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
103
2019-11-21
Smart Machine Smart Decision
If write successfully:
+CMGW: <index>
OK
lF
ile
If cancel write:
OK
If write fails:
ERROR
If write fails:
+CMS ERROR: <err>
ia
If text mode(AT+CMGF=1):
AT+CMGW=<oa>/<da>[,<t
ooa>/<toda>[,<stat>]]<CR>
Text is entered.
<CTRL-Z/ESC>
If PDU mode(AT+CMGF=
0):
AT+CMGW=<length>[,<sta
t>]<CR>PDU is entered.
<CTRL-Z/ESC>
nt
Defined values
SI
M
C
om
C
on
f
id
e
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <tooa>.
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda>).
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length>
Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP
data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length).
<stat>
1. Text Mode:
"STO UNSENT" stored unsent message
"STO SENT"
stored sent message
2. PDU Mode:
2 – stored unsent message
3 – stored sent message
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
104
2019-11-21
Smart Machine Smart Decision
Examples
6.16
lF
ile
AT+CMGW="13012832788" <CR> (TEXT MODE)
ABCD<ctrl-Z/ESC>
+CMGW:1
OK
AT+CMGD Delete message
Description
YES
References
3GPP TS 27.005
id
e
SIM PIN
nt
ia
This command is used to delete message from preferred message storage <mem1> location
<index>. If <delflag> is present and not set to 0 then the ME shall ignore <index> and follow the
rules for <delflag> shown below.
Syntax
Responses
+CMGD: (list
<delflag>s)]
of
supported
C
on
f
Test Command
AT+CMGD=?
<index>s)[,(list
of
supported
OK
Write Command
AT+CMGD=
<index>[,<delflag>]
Responses
OK
ERROR
C
om
+CMS ERROR: <err>
Defined values
SI
M
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<delflag>
0 – (or omitted) Delete the message specified in <index>.
1 – Delete all read messages from preferred message storage, leaving unread messages and
stored mobile originated messages (whether sent or not) untouched.
2 – Delete all read messages from preferred message storage and sent mobile originated
messages, leaving unread messages and unsent mobile originated messages untouched.
3 – Delete all read messages from preferred message storage, sent and unsent mobile
originated messages leaving unread messages untouched.
4 – Delete all messages from preferred message storage including unread messages.
NOTE: If set <delflag>=1, 2, 3 or 4, <index> is omitted, such as AT+CMGD=,1.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
105
2019-11-21
Smart Machine Smart Decision
Examples
6.17
lF
ile
AT+CMGD=1
OK
AT+CMGMT Change message status
Description
YES
References
Vendor
nt
SIM PIN
ia
This command is used to change the message status. If the status is unread, it will be changed read.
Other statuses don’t change.
Responses
OK
Write Command
AT+CMGMT=<index>
Responses
OK
C
on
f
Test Command
AT+CMGMT=?
id
e
Syntax
ERROR
+CMS ERROR: <err>
Defined values
C
om
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
Examples
AT+CMGMT=1
OK
AT+CMVP Set message valid period
M
6.18
SI
Description
This command is used to set valid period for sending short message.
SIM PIN
YES
References
Vendor
SIM7906_SIM7912 Series_AT Command Manual_V1.01
106
2019-11-21
Smart Machine Smart Decision
Syntax
Responses
+CMVP: (list of supported <vp>s)
lF
ile
Test Command
AT+CMVP=?
OK
Read Command
AT+CMVP?
Responses
+CMVP:<vp>
OK
Responses
OK
ia
Write Command
AT+CMVP=<vp>
ERROR
Defined values
Examples
C
om
AT+CMVP=167
OK
AT+CMVP?
+CMVP: 167
OK
C
on
f
id
e
<vp>
Validity period value:
0 to 143
(<vp>+1) x 5 minutes (up to 12 hours)
144 to 167
12 hours + (<vp>-143) x 30 minutes
168 to 196
(<vp>-166) x 1 day
197 to 255
(<vp>-192) x 1 week
nt
+CMS ERROR: <err>
AT+CMGRD
Read and delete message
M
6.19
SI
Description
This command is used to read message, and delete the message at the same time. It integrate
AT+CMGR and AT+CMGD, but it doesn’t change the message status.
SIM PIN
YES
References
Vendor
Syntax
SIM7906_SIM7912 Series_AT Command Manual_V1.01
107
2019-11-21
Smart Machine Smart Decision
Responses
OK
Write Command
AT+CMGRD=<index>
Responses
If text mode(AT+CMGF=1),command successful and SMS-DELIVER:
+CMGRD:<stat>,<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs
>, <sca>,<tosca>,<length>]<CR><LF><data>
lF
ile
Test Command
AT+CMGRD=?
OK
ia
If text mode(AT+CMGF=1),command successful and SMS-SUBMIT:
+CMGRD:<stat>,<da>,[<alpha>][,<toda>,<fo>,<pid>,<dcs>,[<vp
>], <sca>,<tosca>,<length>]<CR><LF><data>
nt
OK
OK
id
e
If text mode(AT+CMGF=1),command successful and SMS-STATUS- REPORT:
+CMGRD: <stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st>
If text mode(AT+CMGF=1),command successful and CBM storage:
+CMGRD:<stat>,<sn>,<mid>,<dcs>,<page>,<pages><CR><LF><
data>
OK
If PDU mode(AT+CMGF=0) and command successful:
+CMGRD: <stat>,[<alpha>],<length><CR><LF><pdu>
OK
ERROR
+CMS ERROR: <err>
M
C
om
C
on
f
If text mode(AT+CMGF=1),command successful and SMS-COMMAND:
+CMGRD:<stat>,<fo>,<ct>[,<pid>,[<mn>],[<da>],[<toda>],<lengt
h><CR><LF><data>]
OK
Defined values
SI
Refer to command AT+CMGR.
Examples
AT+CMGRD=6
+CMGRD:"REC READ","+8613917787249",,"06/07/10,12:09:38+32",145,4,0,0, "+86138002105
00",145,4
SIM7906_SIM7912 Series_AT Command Manual_V1.01
108
2019-11-21
Smart Machine Smart Decision
6.20
lF
ile
How do you do
OK
AT+CMGSEX Send message
Description
This command is used to send message from a TE to the network (SMS-SUBMIT).
YES
References
3GPP TS 27.005
ia
SIM PIN
nt
Syntax
Responses
AT+CMGSEX=?
OK
Write Command
Responses
If text mode (AT+CMGF=1):
AT+CMGSEX=<da>[,<toda
>][,<mr>,
<msg_seg>,
<msg_total>]<CR>Text is
entered.
<CTRL-Z/ESC>
If sending successfully:
id
e
Test Command
+CMGSEX: <mr>
C
on
f
OK
If cancel sending:
OK
If sending fails:
ERROR
If sending fails:
C
om
+CMS ERROR: <err>
Defined values
SI
M
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (When first character of <da> is
+ (IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<msg_seg>
The segment number for long sms
<msg_total>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
109
2019-11-21
Smart Machine Smart Decision
lF
ile
The total number of the segments for long sms. Its range is from 2 to 255.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: For
single SMS, it is 160 characters if the 7 bit GSM coding scheme is used; For multiple long sms, it is
153 characters if the 7 bit GSM coding scheme is used.
Examples
6.21
id
e
nt
ia
AT+CMGSEX="13012832788", 190, 1, 2<CR>(TEXT MODE)
> ABCD<ctrl-Z/ESC>
+CMGSEX: 190
OK
AT+CMGSEX="13012832788", 190, 2, 2<CR>(TEXT MODE)
> EFGH<ctrl-Z/ESC>
+CMGSEX: 190
OK
AT+CMSSEX Send multi messages from storage
Description
SIM PIN
YES
C
on
f
This command is used to send messages with location value <index1>,<index2>,<index3>… from
preferred message storage <mem2> to the network (SMS-SUBMIT or SMS-COMMAND).The
max count of index is 13 one time.
References
3GPP TS 27.005
Syntax
Responses
AT+CMSSEX=?
OK
Write Command
Responses
AT+CMSSEX=
<index> [,<index >[,… ]]
+CMSSEX: <mr>[,<mr>[,…]]
OK
ERROR
If sending fails:
[+CMSSEX: <mr>[,<mr>[,…]]]
+CMS ERROR: <err>
SI
M
C
om
Test Command
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
SIM7906_SIM7912 Series_AT Command Manual_V1.01
110
2019-11-21
Smart Machine Smart Decision
lF
ile
with zero.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
ia
AT+CMSSEX=0,1
+CMSSEX: 239,240
SI
M
C
om
C
on
f
id
e
nt
OK
AT+CMSSEX=0,1
+CMSSEX: 238
+CMS ERROR: Invalid memory index
SIM7906_SIM7912 Series_AT Command Manual_V1.01
111
2019-11-21
7.1
AT Commands for Phonebook
AT+CPBS
lF
ile
7
Select phonebook memory storage
Description
YES
References
3GPP TS 27.007
nt
SIM PIN
ia
This command selects the active phonebook storage, i.e. the phonebook storage that all subsequent
phonebook commands will be operating on.
id
e
Syntax
Responses
+CPBS: (list of supported <storage>s)
OK
Read Command
AT+CPBS?
Responses
C
on
f
Test Command
AT+CPBS=?
+CPBS: <storage>[,<used>,<total>]
OK
+CME ERROR: <err>
Write Command
AT+CPBS=<storage>
Responses
OK
C
om
ERROR
+CME ERROR: <err>
Execution Command
Responses
AT+CPBS
Set default value “SM”:
OK
SI
M
Defined values
<storage>
Values reserved by the present document:
"DC"
ME dialed calls list
Capacity: max. 100 entries
AT+CPBW command is not applicable to this storage.
"MC"
ME missed (unanswered received) calls list
Capacity: max. 100 entries
AT+CPBW command is not applicable to this storage.
"ME"
"FD"
"ON"
"LD"
id
e
"EN"
ia
"SM"
ME received calls list
Capacity: max. 100 entries
AT+CPBW command is not applicable to this storage.
SIM phonebook
Capacity: depending on SIM card
Mobile Equipment phonebook
Capacity: max. 500 entries
SIM fixdialling-phonebook
Capacity:depending on SIM card
MSISDN list
Capacity:depending on SIM card
Last number dialed phonebook
Capacity: depending on SIM card
AT+CPBW command is not applicable to this storage
Emergency numbers
Capacity: depending on SIM card
AT+CPBW command is not applicable to this storage.
nt
"RC"
lF
ile
Smart Machine Smart Decision
Examples
C
on
f
<used>
Integer type value indicating the number of used locations in selected memory.
<total>
Integer type value indicating the total number of locations in selected memory.
C
om
AT+CPBS=?
+CPBS: ("SM","DC","FD","LD","MC","ME","RC","EN","ON")
OK
AT+CPBS=”SM”
OK
AT+CPBS?
+CPBS: "SM",1,200
OK
AT+CPBR Read phonebook entries
M
7.2
SI
Description
This command gets the record information from the selected memory storage in phonebook. If the
storage is selected as “SM” then the command will return the record in SIM phonebook, the same to
others.
SIM PIN
YES
References
3GPP TS 27.007
SIM7906_SIM7912 Series_AT Command Manual_V1.01
113
2019-11-21
Smart Machine Smart Decision
Syntax
Test Command
AT+CPBR=?
Responses
lF
ile
+CPBR: (<minIndex>-<maxIndex>), [<nlength>], [<tlength>]
OK
+CME ERROR: <err>
Responses
[+CPBR: <index1>,<number>,<type>,<text>[<CR><LF>
+CPBR: <index2>,<number>,<type>,<text>[…]]]
ia
Write Command
AT+CPBR=
<index1>[,<index2>]
OK
+CME ERROR: <err>
id
e
Defined values
nt
ERROR
SI
M
C
om
C
on
f
<index1>
Integer type value in the range of location numbers of phonebook memory.
<index2>
Integer type value in the range of location numbers of phonebook memory.
<index>
Integer type.the current position number of the Phonebook index.
<minIndex>
Integer type the minimum <index> number.
<maxIndex>
Integer type the maximum <index> number
<number>
String type, phone number of format <type>, the maximum length is <nlength>.
<type>
Type of phone number octet in integer format, default 145 when dialing string includes international
access code character "+", otherwise 129.
<text>
String type field of maximum length <tlength>; often this value is set as name.
<nlength>
Integer type value indicating the maximum length of field <number>.
<tlength>
Integer type value indicating the maximum length of field <text>.
Examples
AT+CPBS?
+CPBS: "SM",2,200
SIM7906_SIM7912 Series_AT Command Manual_V1.01
114
2019-11-21
Smart Machine Smart Decision
7.3
lF
ile
OK
AT+CPBR=1,10
+CPBR: 1,"1234567890",129,"James"
+CPBR: 2,"0987654321",129,"Kevin"
OK
AT+CPBF Find phonebook entries
Description
nt
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+CPBF=?
Responses
id
e
SIM PIN
ia
This command finds the record in phonebook (from the current phonebook memory storage
selected with AT+CPBS) which alphanumeric field has substring <findtext>.If <findtext> is null, it
will list all the entries.
C
on
f
+CPBF: [<nlength>],[<tlength>]
OK
+CME ERROR: <err>
Write Command
AT+CPBF=[<findtext>]
Responses
[+CPBF: <index1>,<number>,<type>,<text>[<CR><LF>
+CPBF: <indexN>,<number>,<type>,<text>[…]]]
C
om
OK
ERROR
+CME ERROR: <err>
Defined values
SI
M
<findtext>
String type, this value is used to find the record. Character set should be the one selected with
command AT+CSCS.
<index>
Integer type values in the range of location numbers of phonebook memory.
<number>
String type, phone number of format <type>, the maximum length is <nlength>.
<type>
Type of phone number octet in integer format, default 145 when dialing string includes international
access code character "+", otherwise 129.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
115
2019-11-21
<text>
String type field of maximum length <tlength>; Often this value is set as name.
<nlength>
Integer type value indicating the maximum length of field <number>.
<tlength>
Integer type value indicating the maximum length of field <text>.
Examples
AT+CPBW Write phonebook entry
id
e
Description
nt
7.4
ia
AT+CPBF=" James "
+CPBF: 1,"1234567890",129," James "
OK
lF
ile
Smart Machine Smart Decision
This command writes phonebook entry in location number <index> in the current phonebook
memory storage selected with AT+CPBS.
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+CPBW=?
C
on
f
SIM PIN
Responses
+CPBW:(list of supported <index>s),[<nlength>],
C
om
(list of supported <type>s),[<tlength>]
OK
+CME ERROR:<err>
Write Command
Responses
AT+CPBW=[<index>][,<nu
mber>[,<type>[,<text>]]]
OK
ERROR
M
+CME ERROR:<err>
SI
Defined values
<index>
Integer type values in the range of location numbers of phonebook memory. If <index> is not given,
the first free entry will be used. If <index> is given as the only parameter, the phonebook entry
specified by <index> is deleted. If record number <index> already exists, it will be overwritten.
<number>
String type, phone number of format <type>, the maximum length is <nlength>.It must be an
SIM7906_SIM7912 Series_AT Command Manual_V1.01
116
2019-11-21
Smart Machine Smart Decision
lF
ile
non-empty string.
<type>
Type of address octet in integer format, The range of value is from 129 to 255. If <number>
contains a leading “+” <type> = 145 (international) is used. Supported value are:
145 – when dialling string includes international access code character “+”
161 – national number. The network support for this type is optional
177 – network specific number, ISDN format
129 – otherwise
id
e
nt
ia
NOTE: Other value refer TS 24.008 [8] subclause 10.5.4.7.
<text>
String type field of maximum length <tlength>; character set as specified by command Select TE
Character Set AT+CSCS.
<nlength>
Integer type value indicating the maximum length of field <number>.
<tlength>
Integer type value indicating the maximum length of field <text>.
NOTE: If the parameters of <type> and <text> are omitted and the first character of <number> is
‘+’,it will specify <type> as 145(129 if the first character isn’t ‘+’) and <text> as NULL.
C
on
f
Examples
C
om
AT+CPBW=3,"88888888",129,"John"
OK
AT+CPBW=,”6666666”,129,”mary”
OK
AT+CPBW=1
OK
7.5
AT+CNUM
Subscriber number
Description
SI
M
Execution command returns the MSISDNs related to the subscriber (this information can be stored
in the SIM or in the ME). If subscriber has different MSISDN for different services, each MSISDN
is returned in a separate line.
SIM PIN
YES
References
3GPP TS 27.007
Syntax
Test Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
117
2019-11-21
Smart Machine Smart Decision
OK
Execution Command
Responses
AT+CNUM
[+CNUM: <alpha>,<number>,<type>[<CR><LF>
+CNUM: <alpha>, <number>,<type> [...]]]
OK
lF
ile
AT+CNUM=?
+CME ERROR: <err>
Defined values
Examples
SI
M
C
om
C
on
f
AT+CNUM
+CNUM: "","13697252277",129
OK
id
e
nt
ia
<alpha>
Optional alphanumeric string associated with <number>, used character set should be the one
selected with command Select TE Character Set AT+CSCS.
<number>
String type phone number of format specified by <type>.
<type>
Type of address octet in integer format. see also AT+CPBR <type>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
118
2019-11-21
Smart Machine Smart Decision
AT Commands for GPRS
8.1
AT+CGREG GPRS network registration status
Description
lF
ile
8
nt
NO
References
3GPP TS 27.007
Syntax
Test Command
AT+CGREG=?
Responses
+CGREG: (list of supported <n>s)
C
on
f
OK
Read Command
AT+CGREG?
id
e
SIM PIN
ia
This command controls the presentation of an unsolicited result code “+CGREG: <stat>” when
<n>=1 and there is a change in the MT's GPRS network registration status.
The read command returns the status of result code presentation and an integer <stat> which shows
Whether the network has currently indicated the registration of the MT.
Responses
+CGREG: <n>,<stat>[,<lac>,<ci>]
OK
C
om
Write Command
AT+CGREG=<n>
Execution Command
AT+CGREG
Responses
OK
Responses
Set default value:
OK
Defined values
<n>
M
0
1
2
– disable network registration unsolicited result code
– enable network registration unsolicited result code +CGREG: <stat>
– there is a change in the ME network registration status or a change of the network cell:
+CGREG: <stat>[,<lac>,<ci>]
SI
<stat>
0 – not registered, ME is not currently searching an operator to register to
1 – registered, home network
2 – not registered, but ME is currently trying to attach or searching an operator to register
to
3 – registration denied
SIM7906_SIM7912 Series_AT Command Manual_V1.01
119
2019-11-21
Smart Machine Smart Decision
lF
ile
4 – unknown
5 – registered, roaming
<lac>
Two bytes location area code in hexadecimal format (e.g.”00C3” equals 193 in decimal).
<ci>
Cell ID in hexadecimal format.
WCDMA : Maximum is four byte
ia
Examples
id
e
AT+CGATT Packet domain attach or detach
Description
C
on
f
8.2
nt
AT+CGREG=?
+CGREG: (0-1)
OK
AT+CGREG?
+CGREG: 0,0
OK
The write command is used to attach the MT to, or detach the MT from, the Packet Domain service.
The read command returns the current Packet Domain service state.
SIM PIN
3GPP TS 27.007
C
om
YES
References
Syntax
Test Command
AT+CGATT=?
ERROR
Read Command
Responses
AT+CGATT?
+CGATT: <state>
OK
M
SI
Responses
+CGATT: (list of supported <state>s)
OK
ERROR
Write Command
Responses
AT+CGATT=<state>
OK
ERROR
+CME ERROR: <err>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
120
2019-11-21
Smart Machine Smart Decision
Defined values
lF
ile
<state>
Indicates the state of Packet Domain attachment:
0 – detached
1 – attached
Examples
nt
ia
AT+CGATT?
+CGATT: 0
OK
AT+CGATT=1
OK
AT+CGACT PDP context activate or deactivate
id
e
8.3
Description
The write command is used to activate or deactivate the specified PDP context (s).
YES
References
C
on
f
SIM PIN
3GPP TS 27.007
Syntax
Test Command
AT+CGACT=?
Responses
AT+CGACT?
+CGACT: [<cid>,<state> [<CR><LF>
+CGACT: <cid>,<state>
[...]]]
OK
Write Command
Responses
AT+CGACT=<state>[,<cid>
]
OK
C
om
Read Command
M
SI
Responses
+CGACT: (list of supported <state>s)
OK
ERROR
+CME ERROR: <err>
Defined values
<state>
Indicates the state of PDP context activation:
0 – deactivated
SIM7906_SIM7912 Series_AT Command Manual_V1.01
121
2019-11-21
Smart Machine Smart Decision
lF
ile
1 – activated
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command).
1…24
Examples
nt
id
e
8.4
ia
AT+CGACT?
+CGACT: 1,1
OK
AT+CGACT=?
+CGACT: (0,1)
OK
AT+CGACT=0,1
OK
AT+CGDCONT Define PDP context
C
on
f
Description
The set command specifies PDP context parameter values for a PDP context identified by the
(local) context identification parameter <cid>. The number of PDP contexts that may be in a
defined state at the same time is given by the range returned by the test command. A special form of
the write command (AT+CGDCONT=<cid>) causes the values for context <cid> to become
undefined.
SIM PIN
3GPP TS 27.007
C
om
YES
References
Syntax
Responses
AT+CGDCONT=?
+CGDCONT: (range of supported<cid>s),<PDP_type>,,,(list of
supported <d_comp>s),(list of supported <h_comp>s)(list of
<ipv4_ctrl>s),(list of <emergency_flag>s)
OK
SI
M
Test Command
ERROR
Read Command
Responses
AT+CGDCONT?
+CGDCONT: [<cid>, <PDP_type>, <APN>,<PDP_addr>,
<d_comp>, <h_comp>,<ipv4_ctrl>,<emergency_flag>[<CR><LF>
+CGDCONT: <cid>, <PDP_type>, <APN>, <PDP_addr>,
<d_comp>, <h_comp>,< ipv4_ctrl>,<emergency_flag>[...]]]
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
122
2019-11-21
Smart Machine Smart Decision
Write Command
Responses
AT+CGDCONT=<cid>[,<P
DP_type>[,<APN>[,<PDP_a
ddr>[,<d_comp>[,<h_comp>
][,<ipv4_ctrl>[,<emergency_
flag>]]]]]]
OK
Execution Command
Responses
AT+CGDCONT
OK
lF
ile
ERROR
ERROR
ia
ERROR
nt
Defined values
SI
M
C
om
C
on
f
id
e
<cid>
(PDP Context Identifier) a numeric parameter which specifies a particular PDP context definition.
The parameter is local to the TE-MT interface and is used in other PDP context-related commands.
The range of permitted values (minimum value = 1) is returned by the test form of the command.
1…24
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<APN>
(Access Point Name) a string parameter which is a logical name that is used to select the GGSN or
the external packet data network.
<PDP_addr>
A string parameter that identifies the MT in the address space applicable to the PDP.
Read command will continue to return the null string even if an address has been allocated during
the PDP startup procedure. The allocated address may be read using command AT+CGPADDR.
<d_comp>
A numeric parameter that controls PDP data compression, this value may depend on platform:
0 – off (default if value is omitted)
1 – on
2 – V.42bis
3 – V.44
<h_comp>
A numeric parameter that controls PDP header compression, this value may depend on platform:
0 – off (default if value is omitted)
1 – on
2 – RFC1144
SIM7906_SIM7912 Series_AT Command Manual_V1.01
123
2019-11-21
Smart Machine Smart Decision
Examples
id
e
nt
AT+CGDCONT?
+CGDCONT: 1,"IPV4V6","","0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0",0,0,0,0
+CGDCONT: 2,"IPV6","ims","0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0",0,0,0,0
+CGDCONT: 3,"IPV4V6","","0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0",0,0,0,1
ia
lF
ile
3 – RFC2507
4 – RFC3095
<ipv4_ctrl>
Parameter that controls how the MT/TA requests to get the IPv4 address information:
0 – Address Allocation through NAS Signaling
1 – on
<emergency_flag>
emergency_flag:
0 – off (default if value is omitted)
1 – on
C
on
f
OK
AT+CGDCONT=?
+CGDCONT: (1-24),"IP",,,(0-3),(0-4),(0-1),(0-1)
+CGDCONT: (1-24),"PPP",,,(0-3),(0-4),(0-1),(0-1)
+CGDCONT: (1-24),"IPV6",,,(0-3),(0-4),(0-1),(0-1)
+CGDCONT: (1-24),"IPV4V6",,,(0-3),(0-4),(0-1),(0-1)
OK
AT+CGDSCONT Define Secondary PDP Context
C
om
8.5
Description
M
The set command specifies PDP context parameter values for a Secondary PDP context identified
by the (local) context identification parameter, <cid>. The number of PDP contexts that may be in a
defined state at the same time is given by the range returned by the test command. A special form of
the set command, AT+CGDSCONT=<cid> causes the values for context number <cid> to become
undefined.
SIM PIN
3GPP TS 27.007
SI
YES
References
Syntax
Test Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
124
2019-11-21
Smart Machine Smart Decision
+CGDSCONT: (range of supported <cid>s),(list of <p_cid>s for
active primary contexts), <PDP_type>, (list of supported
<d_comp>s),(list of supported <h_comp>s)
lF
ile
AT+CGDSCONT=?
OK
ERROR
Read Command
Responses
AT+CGDSCONT?
+CGDSCONT: [<cid>,<p_cid>,<d_comp>,<h_comp>
[<CR><LF>+CGDSCONT: <cid>,<p_cid>,<d_comp>,<h_comp>
ia
[...]]]
OK
Responses
AT+CGDSCONT=<cid>[,<
p_cid>[,<d_comp>[,<h_com
p>]]]
OK
C
on
f
Defined values
ERROR
id
e
Write Command
nt
ERROR
<cid>
a numeric parameter which specifies a particular PDP context definition. The parameter is local to
the TE-MT interface and is used in other PDP context-related commands. The range of permitted
values (minimum value = 1) is returned by the test form of the command.
SI
M
C
om
NOTE: The <cid>s for network-initiated PDP contexts will have values outside the ranges
indicated for the <cid> in the test form of the commands +CGDCONT and +CGDSCONT.
<p_cid>
a numeric parameter which specifies a particular PDP context definition which has been specified
by use of the +CGDCONT command. The parameter is local to the TE-MT interface. The list of
permitted values is returned by the test form of the command.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<d_comp>
a numeric parameter that controls PDP data compression (applicable for SNDCPonly) (refer
3GPP TS 44.065 [61])
0
off
1
on (manufacturer preferred compression)
SIM7906_SIM7912 Series_AT Command Manual_V1.01
125
2019-11-21
Smart Machine Smart Decision
2
3
V.42bis
V.44
lF
ile
Other values are reserved.
nt
ia
<h_comp>
a numeric parameter that controls PDP header compression (refer 3GPP TS 44.065 [61] and
3GPP TS 25.323 [62])
0
off
1
on (manufacturer preferred compression)
2
RFC1144 (applicable for SNDCP only)
3
RFC2507
4
RFC3095 (applicable for PDCP only)
Other values are reserved.
AT+CGDSCONT?
+CGDSCONT: 2,1,0,0
id
e
Examples
C
om
C
on
f
OK
AT+CGDSCONT=2,1
OK
AT+CGDSCONT=?
+CGDSCONT: (1-24),(),"IP",(0-3),(0-4)
+CGDSCONT: (1-24),(),"PPP",(0-3),(0-4)
+CGDSCONT: (1-24),(),"IPV6",(0-3),(0-4)
+CGDSCONT: (1-24),(),"IPV4V6",(0-3),(0-4)
OK
8.6
AT+CGTFT Traffic Flow Template
Description
SI
M
This command allows the TE to specify a Packet Filter - PF for a Traffic Flow Template - TFT that
is used in the GGSN in UMTS/GPRS and Packet GW in EPS for routing of packets onto different
QoS flows towards the TE. The concept is further described in the 3GPP TS 23.060 [47]. A TFT
consists of from one and up to 16 Packet Filters, each identified by a unique <packet filter
identifier>. A Packet Filter also has an <evaluation precedence index> that is unique within all TFTs
associated with all PDP contexts that are associated with the same PDP address.
SIM PIN
YES
References
3GPP TS 27.007
Syntax
SIM7906_SIM7912 Series_AT Command Manual_V1.01
126
2019-11-21
Smart Machine Smart Decision
Responses
+CGTFT: <PDP_type>,(list
of
supported
<packet
filter
identifier>s),(list
of
supported
<evaluation
precedence
index>s),(list of supported <source address and subnet
mask>s),(list of supported <protocol number (ipv4) / next header
(ipv6)>s),(list of supported <destination port range>s),(list of
supported <source port range>s),(list of supported <ipsec security
parameter index (spi)>s),(list of supported <type of service (tos)
(ipv4) and mask / traffic class (ipv6) and mask>s),(list of supported
<flow label (ipv6)>s)
[<CR><LF>+CGTFT: <PDP_type>,(list of supported <packet filter
identifier>s),(list
of
supported
<evaluation
precedence
index>s),(list of supported <source address and subnet
mask>s),(list of supported <protocol number (ipv4) / next header
(ipv6)>s),(list of supported <destination port range>s),(list of
supported <source port range>s),(list of supported <ipsec security
parameter index (spi)>s),(list of supported <type of service (tos)
(ipv4) and mask / traffic class (ipv6) and mask>s),(list of supported
<flow label (ipv6)>s)
[...]]
C
on
f
id
e
nt
ia
lF
ile
Test Command
AT+CGTFT=?
OK
ERROR
Read Command
SI
M
C
om
AT+CGTFT?
Responses
+CGTFT: [<cid>,<packet filter identifier>,<evaluation precedence
index>,<source address and subnet mask>,<protocol number (ipv4)
/ next header (ipv6)>,<destination port range>,<source port
range>,<ipsec security parameter index (spi)>,<type of service (tos)
(ipv4) and mask / traffic class (ipv6) and mask>,<flow label
(ipv6)>
[<CR><LF>+CGTFT: <cid>,<packet filter identifier>,<evaluation
precedence index>,<source address and subnet mask>,<protocol
number (ipv4) / next header (ipv6)>,<destination port
range>,<source port range>,<ipsec security parameter index
(spi)>,<type of service (tos) (ipv4) and mask / traffic class (ipv6)
and mask>,<flow label (ipv6)>
[...]]]
OK
ERROR
Write Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
127
2019-11-21
Smart Machine Smart Decision
AT+CGTFT=<cid>[,[<packe
t
filter
identifier>,<evaluation
precedence index>[,<source
address
and
subnet
mask>[,<protocol
number
(ipv4)
/
next
header
(ipv6)>[,<destination
port
range>[,<source
port
range>[,<ipsec
security
parameter
index
(spi)>[,<type of service (tos)
(ipv4) and mask / traffic
class
(ipv6)
and
mask>[,<flow
label
(ipv6)>]]]]]]]]]
OK
Execute Command
Responses
AT+CGTFT
OK
Defined values
C
on
f
ERROR
id
e
nt
ia
lF
ile
ERROR
SI
M
C
om
<cid>
a numeric parameter which specifies a particular PDP context definition (see the AT+CGDCONT
and AT+CGDSCONT commands).
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<packet filter identifier>
a numeric parameter, value range from 1 to 16.
<evaluation precedence index>
a numeric parameter. The value range is from 0 to 255.
<source address and subnet mask>
string type The string is given as dot-separated numeric (0-255) parameters on the form:
"a1.a2.a3.a4.m1.m2.m3.m4" for IPv4 or
"a1.a2.a3.a4.a5.a6.a7.a8.a9.a10.a11.a12.a13.a14.a15.a16.m1.m2.m3.m4.m5.m6.m7.m8.m9.m10.m1
1.m12.m13.m14.m15.m16", for IPv6.
<protocol number (ipv4) / next header (ipv6)>
a numeric parameter, value range from 0 to 255.
<destination port range>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
128
2019-11-21
Smart Machine Smart Decision
Examples
nt
AT+CGTFT?
+CGTFT: 2,1,0,"74.125.71.99.255.255.255.255",0,0.0,0.0,0,0.0,0
ia
lF
ile
string type. The string is given as dot-separated numeric (0-65535) parameters on the form "f.t".
<source port range>
string type. The string is given as dot-separated numeric (0-65535) parameters on the form "f.t".
<ipsec security parameter index (spi)>
numeric value in hexadecimal format. The value range is from 00000000 to FFFFFFFF.
<type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>
string type. The string is given as dot-separated numeric (0-255) parameters on the form "t.m".
<flow label (ipv6)>
numeric value in hexadecimal format. The value range is from 00000 to FFFFF. Valid for IPv6 only.
C
om
C
on
f
id
e
OK
AT+CGTFT=2,1,0,"74.125.71.99.255.255.255.255"
OK
AT+CGTFT=?
+CGTFT:
"IP",(1-16),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFFFFF),(0-255.0-255),(
0-FFFFF)
+CGTFT:
"PPP",(1-16),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFFFFF),(0-255.0-255
),(0-FFFFF)
+CGTFT:
"IPV6",(1-16),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFFFFF),(0-255.0-25
5),(0-FFFFF)
+CGTFT:
"IPV4V6",(1-16),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFFFFF),(0-255.0255),(0-FFFFF)
OK
AT+CGQREQ Quality of service profile (requested)
M
8.7
SI
Description
This command allows the TE to specify a Quality of Service Profile that is used when the MT sends
an Activate PDP Context Request message to the network.. A special form of the set command
(AT+CGQREQ=<cid>) causes the requested profile for context number <cid> to become
undefined.
SIM PIN
YES
References
3GPP TS 27.007
SIM7906_SIM7912 Series_AT Command Manual_V1.01
129
2019-11-21
Smart Machine Smart Decision
Syntax
Responses
+CGQREQ: <PDP_type>, (list of supported <precedence>s), (list
of supported <delay>s), (list of supported <reliability>s) , (list of
supported <peak>s), (list of supported <mean>s) [<CR><LF>
+CGQREQ: <PDP_type>, (list of supported <precedence>s), (list
of supported <delay>s), (list of supported <reliability>s) , (list of
supported <peak>s), (list of supported <mean>s)
[…]]
OK
ia
lF
ile
Test Command
AT+CGQREQ=?
ERROR
Responses
AT+CGQREQ?
+CGQREQ: [<cid>, <precedence >, <delay>, <reliability>,
<peak>, <mean>[<CR><LF>
+CGQREQ: <cid>, <precedence >, <delay>, <reliability.>, <peak>,
<mean>[…]]]
OK
ERROR
Responses
C
on
f
Write Command
id
e
nt
Read Command
AT+CGQREQ=<cid>[,<prec
edence>[,<delay>[,<reliabilit
y>[,<peak>[,<mean>]]]]]
OK
Execution Command
Responses
AT+CGQREQ
OK
ERROR
C
om
ERROR
Defined values
SI
M
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command). The range is from 1 to 24.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<precedence>
A numeric parameter which specifies the precedence class:
0 – network subscribed value
SIM7906_SIM7912 Series_AT Command Manual_V1.01
130
2019-11-21
Smart Machine Smart Decision
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
1 – high priority
2 – normal priority
3 – low priority
<delay>
A numeric parameter which specifies the delay class:
0 – network subscribed value
1 – delay class 1
2 – delay class 2
3 – delay class 3
4 – delay class 4
<reliability>
A numeric parameter which specifies the reliability class:
0 – network subscribed value
1 – Non real-time traffic,error-sensitive application that cannot cope with data loss
2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss
3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/SM,and SMS
4 – Real-time traffic,error-sensitive application that can cope with data loss
5 – Real-time traffic error non-sensitive application that can cope with data loss
<peak>
A numeric parameter which specifies the peak throughput class:
0 – network subscribed value
1 – Up to 1000 (8 kbit/s)
2 – Up to 2000 (16 kbit/s)
3 – Up to 4000 (32 kbit/s)
4 – Up to 8000 (64 kbit/s)
5 – Up to 16000 (128 kbit/s)
6 – Up to 32000 (256 kbit/s)
7 – Up to 64000 (512 kbit/s)
8 – Up to 128000 (1024 kbit/s)
9 – Up to 256000 (2048 kbit/s)
<mean>
A numeric parameter which specifies the mean throughput class:
0
– network subscribed value
1
– 100 (~0.22 bit/s)
2
– 200 (~0.44 bit/s)
3
– 500 (~1.11 bit/s)
4
– 1000 (~2.2 bit/s)
5
– 2000 (~4.4 bit/s)
6
– 5000 (~11.1 bit/s)
7
– 10000 (~22 bit/s)
8
– 20000 (~44 bit/s)
9
– 50000 (~111 bit/s)
SIM7906_SIM7912 Series_AT Command Manual_V1.01
131
2019-11-21
Smart Machine Smart Decision
lF
ile
100000 (~0.22 kbit/s)
200000 (~0.44 kbit/s)
500000 (~1.11 kbit/s)
1000000 (~2.2 kbit/s)
2000000 (~4.4 kbit/s)
5000000 (~11.1 kbit/s)
10000000 (~22 kbit/s)
20000000 (~44 kbit/s)
50000000 (~111 kbit/s)
optimization
ia
10 –
11 –
12 –
13 –
14 –
15 –
16 –
17 –
18 –
31 –
C
on
f
id
e
AT+CGQREQ?
+CGQREQ:
OK
AT+CGQREQ=?
+CGQREQ: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQREQ: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQREQ: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQREQ: "IPV4V6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
nt
Examples
OK
8.8
AT+CGEQREQ
Description
3G quality of service profile (requested)
M
C
om
The test command returns values supported as a compound value.
The read command returns the current settings for each defined context for which a QOS was
explicitly specified.
The write command allows the TE to specify a Quality of Service Profile for the context identified
by the context identification parameter <cid> which is used when the MT sends an Activate PDP
Context Request message to the network.
A special form of the write command, AT+CGEQREQ=<cid> causes the requested profile for
context number <cid> to become undefined.
SIM PIN
3GPP TS 27.007
SI
YES
References
Syntax
Test Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
132
2019-11-21
Smart Machine Smart Decision
+CGEQREQ: <PDP_type>,(list of supported <Traffic class>s),(list
of supported <Maximum bitrate UL>s),(list of supported
<Maximum bitrate DL>s),(list of supported <Guaranteed bitrate
UL>s,(list of supported <Guaranteed bitrate DL>s),(list of
supported <Deliv ery order>s),(list of supported <Maximum SDU
size>s),(list of supported <SDU error ratio>s),(list of supported
<Residual bit error Ratio>s),(list of supported <Delivery of
erroneous SDUs>s),(list of Supported <Transfer delay>s),(list of
supported <Traffic handling priority>s),(list of supported <Source
statistics descriptor>s),(list of supported <Signaling indication
flag>s)
OK
ia
lF
ile
AT+CGEQREQ=?
nt
ERROR
Responses
AT+CGEQREQ?
+CGEQREQ: [<cid>,<Traffic class>,<Maximum bitrate UL>,
<Maximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed
bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error
ratio>,<Residual bit error ratio>,<Delivery of erroneous SDUs>,
<Transfer Delay>,<Traffic handling priority>,<Source statistics
descriptor>,< Signaling indication flag>][<CR><LF>+CGEQREQ:
<cid>,<Traffic class>,<Maximum bitrate UL>,<Maximum bitrate
DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery
order>,<Maximum SDU size>,<SDU error ratio>,<Residual bit
error ratio>,<Delivery of erroneous SDUs>,<Transfer Delay>,
<Traffic handling priority>,<Source statistics descriptor>,
<Signaling indication flag> […]]
OK
C
om
C
on
f
id
e
Read Command
Write Command
Responses
AT+CGEQREQ=<cid>[,<Tr
affic class>[,<Maximum bit
rate UL>[,<Maximum bitrat
e DL>[,<Guaranteed bitrate
UL>[,<Guaranteed bitrate
DL>[,<Delivery order>[,<M
aximum SDU size>[,<SDU
error ratio>[,<Residual bit
error ratio>[,<Delivery of
erroneous SDUs>[,<Transfe
r delay>[,<Traffic handling
priority>[,<Source statistic
s descriptor>[,<Signaling in
OK
M
SI
ERROR
ERROR
+CME ERROR: <err>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
133
2019-11-21
Smart Machine Smart Decision
Execution Command
Responses
AT+CGEQREQ
OK
lF
ile
dication flag>]]]]]]]]]]]]]]
ERROR
ia
Defined values
SI
M
C
om
C
on
f
id
e
nt
<cid>
Parameter specifies a particular PDP context definition. The parameter is also used in other PDP
context-related commands. The range is from 1 to 24.
<Traffic class>
0 – conversational
1 – streaming
2 – interactive
3 – background
4 – subscribed value
<Maximum bitrate UL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a
SAP. As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQREQ=…,32,…).
The range is from 0 to 11520. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Maximum bitrate DL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQREQ=…,32,…).
The range is from 0 to 42200. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Guaranteed bitrate UL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.AT+CGEQREQ=…,32,…).
The range is from 0 to 11520. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Guaranteed bitrate DL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.AT+CGEQREQ=…,32,…).
The range is from 0 to 42200. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Delivery order>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
134
2019-11-21
Smart Machine Smart Decision
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.
0
– no
1
– yes
2
– subscribed value
<Maximum SDU size>
This parameter indicates the maximum allowed SDU size in octets.
The range is from 0 to 1520. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<SDU error ratio>
This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU
error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10-3
would be specified as “5E3”(e.g.AT+CGEQREQ=..,”5E3”,…).
“0E0” – subscribed value
“1E2”
“7E3”
“1E3”
“1E4”
“1E5”
“1E6”
“1E1”
<Residual bit error ratio>
This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If
no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered
SDUs.As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”(e.g.
AT+CGEQREQ=…,”5E3”,..).
“0E0” – subscribed value
“5E2”
“1E2”
“5E3”
“4E3”
“1E3”
“1E4”
“1E5”
“1E6”
“6E8”
<Delivery of erroneous SDUs>
This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
0 – no
1 – yes
2 – no detect
3 – subscribed value
<Transfer delay>
This parameter indicates the targeted time between request to transfer an SDU at one SAP to its
SIM7906_SIM7912 Series_AT Command Manual_V1.01
135
2019-11-21
Smart Machine Smart Decision
Examples
C
on
f
id
e
nt
ia
lF
ile
delivery at the other SAP,in milliseconds.
The range is 0 and from 100 to 4000. The default value is 0. If the parameter is set to '0' the
subscribed value will be requested.
<Traffic handling priority>
This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS
Bearer compared to the SDUs of the other bearers.
The range is from 0 to 3. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<Source statistics descriptor>
This parameter indicates profile parameter that Source statistics descriptor for requested UMTS
QoS
The range is from 0 to 1. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<Signaling indication flag>
This parameter indicates Signaling flag.
The range is from 0 to 1 The default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
SI
M
C
om
AT+CGEQREQ?
+CGEQREQ:
OK
AT+CGEQREQ=?
+CGEQREQ: "IP",(0-4),(0-11520),(0-42200),(0-11520),(0-42200),(0-2),(0-1520),("0E0","1E
1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E
4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
+CGEQREQ: "PPP",(0-4),(0-11520),(0-42200),(0-11520),(0-42200),(0-2),(0-1520),("0E0","1
E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1
E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
+CGEQREQ: "IPV6",(0-4),(0-11520),(0-42200),(0-11520),(0-42200),(0-2),(0-1520),("0E0","
1E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","
1E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
+CGEQREQ:"IPV4V6",(0-4),(0-11520),(0-42200),(0-11520),(0-42200),(0-2),(0-1520),("0E0","1E1
","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4","1E5","1
E6","6E8"),(0-3),(0,100-4000),(0-3),(0-1),(0-1)
SIM7906_SIM7912 Series_AT Command Manual_V1.01
136
2019-11-21
Smart Machine Smart Decision
OK
AT+CGQMIN Quality of service profile (minimum acceptable)
lF
ile
8.9
Description
This command allows the TE to specify a minimum acceptable profile which is checked by the MT
against the negotiated profile returned in the Activate PDP Context Accept message.A special form
of the set command,AT+CGQMIN=<cid> causes the minimum acceptable profile for context
number <cid> to become undefined.
ia
YES
References
3GPP TS 27.007
nt
SIM PIN
Syntax
Responses
+CGQMIN: <PDP_type>, (list of supported <precedence>s), (list
of supported <delay>s), (list of supported <reliability>s) , (list of
supported <peak>s), (list of supported <mean>s) [<CR><LF>
+CGQMIN: <PDP_type>, (list of supported <precedence>s), (list
of supported <delay>s), (list of supported <reliability>s) , (list of
supported <peak>s), (list of supported <mean>s)[…]]
OK
C
on
f
id
e
Test Command
AT+CGQMIN=?
ERROR
C
om
Read Command
AT+CGQMIN?
ERROR
Write Command
AT+CGQMIN=<cid>[,<prec
edence>[,<delay>[,<reliabilit
y>[,<peak> [,<mean>]]]]]
Responses
OK
Execution Command
AT+CGQMIN
Responses
OK
M
SI
Responses
+CGQMIN: [<cid>, <precedence >, <delay>, <reliability>,
<peak>, <mean>[<CR><LF>
+CGQMIN: <cid>, <precedence >, <delay>, <reliability.>, <peak>,
<mean>
[…]]]
OK
ERROR
ERROR
Defined values
SIM7906_SIM7912 Series_AT Command Manual_V1.01
137
2019-11-21
Smart Machine Smart Decision
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command). The range is from 1 to 24.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<precedence>
A numeric parameter which specifies the precedence class:
0 – network subscribed value
1 – high priority
2 – normal priority
3 – low priority
<delay>
A numeric parameter which specifies the delay class:
0 – network subscribed value
1 – delay class 1
2 – delay class 2
3 – delay class 3
4 – delay class 4
<reliability>
A numeric parameter which specifies the reliability class:
0 – network subscribed value
1 – Non real-time traffic,error-sensitive application that cannot cope with data loss
2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss
3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/SM,and SMS
4 – Real-time traffic,error-sensitive application that can cope with data loss
5 – Real-time traffic error non-sensitive application that can cope with data loss
<peak>
A numeric parameter which specifies the peak throughput class:
0 – network subscribed value
1 – Up to 1000 (8 kbit/s)
2 – Up to 2000 (16 kbit/s)
3 – Up to 4000 (32 kbit/s)
4 – Up to 8000 (64 kbit/s)
5 – Up to 16000 (128 kbit/s)
6 – Up to 32000 (256 kbit/s)
7 – Up to 64000 (512 kbit/s)
8 – Up to 128000 (1024 kbit/s)
9 – Up to 256000 (2048 kbit/s)
SIM7906_SIM7912 Series_AT Command Manual_V1.01
138
2019-11-21
Examples
ia
C
on
f
id
e
nt
<mean>
A numeric parameter which specifies the mean throughput class:
0
– network subscribed value
1
– 100 (~0.22 bit/s)
2
– 200 (~0.44 bit/s)
3
– 500 (~1.11 bit/s)
4
– 1000 (~2.2 bit/s)
5
– 2000 (~4.4 bit/s)
6
– 5000 (~11.1 bit/s)
7
– 10000 (~22 bit/s)
8
– 20000 (~44 bit/s)
9
– 50000 (~111 bit/s)
10 – 100000 (~0.22 kbit/s)
11 – 200000 (~0.44 kbit/s)
12 – 500000 (~1.11 kbit/s)
13 – 1000000 (~2.2 kbit/s)
14 – 2000000 (~4.4 kbit/s)
15 – 5000000 (~11.1 kbit/s)
16 – 10000000 (~22 kbit/s)
17 – 20000000 (~44 kbit/s)
18 – 50000000 (~111 kbit/s)
31 – optimization
lF
ile
Smart Machine Smart Decision
C
om
AT+CGQMIN?
+CGQMIN:
OK
AT+CGQMIN=?
+CGQMIN: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQMIN: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQMIN: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQMIN: "IPV4V6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
M
OK
SI
8.10
AT+CGEQMIN 3G quality of service profile (minimum acceptable)
Description
The test command returns values supported as a compound value.
The read command returns the current settings for each defined context for which a QOS was
explicitly specified.
The write command allow the TE to specify a Quallity of Service Profile for the context identified
SIM7906_SIM7912 Series_AT Command Manual_V1.01
139
2019-11-21
Smart Machine Smart Decision
SIM PIN
YES
lF
ile
by the context identification parameter <cid> which is checked by the MT against the negotiated
profile returned in the Activate/Modify PDP Context Accept message.
A special form of the write command, AT+CGEQMIN=<cid> causes the requested for context
number <cid> to become undefined.
References
3GPP TS 27.007
Syntax
Responses
AT+CGEQMIN=?
+CGEQMIN: <PDP_type>,(list of supported <Traffic class>s),(list
of supported <Maximum bitrate UL>s),(list of supported
<Maximum bitrate DL>s),(list of supported <Guaranteed bitrate
UL>s,(list of supported <Guaranteed bitrate DL>s),(list of
supported <Deliv ery order>s),(list of supported <Maximum SDU
size>s),(list of supported <SDU error ratio>s),(list of supported
<Residual bit error Ratio>s),(list of supported <Delivery of
erroneous SDUs>s),(list of Supported <Transfer delay>s),(list of
supported <Traffic handling priority>s),(list of supported <Source
statistics descriptor>s),(list of supported <Signaling indication
flag>s)
OK
C
on
f
id
e
nt
ia
Test Command
ERROR
Read Command
SI
M
C
om
AT+CGEQMIN?
Responses
+CGEQMIN: [<cid>,<Traffic class>,<Maximum bitrate UL>,
<Maximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed
bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error
ratio>,<Residual bit error ratio>,<Delivery of erroneous SDUs>,
<Transfer Delay>,<Traffic handling priority>,<Source statistics
descriptor>,< Signaling indication flag>][<CR><LF>+CGEQMIN:
<cid>,<Traffic class>,<Maximum bitrate UL>,<Maximum bitrate
DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery
order>,<Maximum SDU size>,<SDU error ratio>,<Residual bit
error ratio>,<Delivery of erroneous SDUs>,<Transfer Delay>,
<Traffic handling priority>,<Source statistics descriptor>,
<Signaling indication flag>[…]]
OK
ERROR
Write Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
140
2019-11-21
AT+CGEQMIN=<cid>[,<Tr
affic class>[,<Maximum bit
rate UL>[,<Maximum bitrat
e DL>[,<Guaranteed bitrate
UL>[,<Guaranteed bitrate
DL>[,<Delivery order>[,<M
aximum SDU size>[,<SDU
error ratio>[,<Residual bit
error ratio>[,<Delivery of
erroneous SDUs>[,<Transfe
r delay>[,<Traffic handling
priority>[,<Source statistic
s descriptor>[,<Signaling in
dication flag>]]]]]]]]]]]]]]
OK
Execution Command
Responses
AT+CGEQMIN
OK
ERROR
C
on
f
id
e
nt
ia
+CME ERROR: <err>
ERROR
Defined values
lF
ile
Smart Machine Smart Decision
SI
M
C
om
<cid>
Parameter specifies a particular PDP context definition. The parameter is also used in other PDP
context-related commands. The range is from 1 to 24.
<Traffic class>
0 – conversational
1 – streaming
2 – interactive
3 – background
4 – subscribed value
<Maximum bitrate UL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQMIN=…,32,…).
The range is from 0 to 11520. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Maximum bitrate DL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQMIN=…,32,…).
The range is from 0 to 42200. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Guaranteed bitrate UL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
SIM7906_SIM7912 Series_AT Command Manual_V1.01
141
2019-11-21
Smart Machine Smart Decision
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
32(e.g.AT+CGEQMIN=…,32,…).
The range is from 0 to 11520. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Guaranteed bitrate DL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.AT+CGEQMIN=…,32,…).
The range is from 0 to 42200. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Delivery order>
This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.
0 – no
1 – yes
2 – subscribed value
<Maximum SDU size>
This parameter indicates the maximum allowed SDU size inoctets.
The range is from 0 to 1520. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<SDU error ratio>
This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU
error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10-3
would be specified as “5E3”(e.g.AT+CGEQMIN=..,”5E3”,…).
“0E0” – subscribed value
“1E2”
“7E3”
“1E3”
“1E4”
“1E5”
“1E6”
“1E1”
<Residual bit error ratio>
This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If
no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered
SDUs.As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”(e.g.
AT+CGEQMIN=…,”5E3”,..).
“0E0” – subscribed value
“5E2”
“1E2”
“5E3”
“4E3”
“1E3”
“1E4”
“1E5”
SIM7906_SIM7912 Series_AT Command Manual_V1.01
142
2019-11-21
Smart Machine Smart Decision
C
om
C
on
f
id
e
nt
ia
lF
ile
“1E6”
“6E8”
<Delivery of erroneous SDUs>
This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
0 – no
1 – yes
2 – no detect
3 – subscribed value
<Transfer delay>
This parameter indicates the targeted time between request to transfer an SDU at one SAP to its
delivery at the other SAP,in milliseconds.
The range is 0 and from 100 to 4000. The default value is 0. If the parameter is set to '0' the
subscribed value will be requested.
<Traffic handling priority>
This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS
Bearer compared to the SDUs of the other bearers.
The range is from 0 to 3. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<Source statistics descriptor>
This parameter indicates profile parameter that Source statistics descriptor for requested UMTS
QoS
The range is from 0 to 1. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<Signaling indication flag>
This parameter indicates Signaling flag.
The range is from 0 to 1 The default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
SI
M
Examples
AT+CGEQMIN?
+CGEQMIN:
OK
AT+CGEQMIN=?
+CGEQMIN: "IP",(0-4),(0-11520),(0-42200),(0-115200),(0-42200),(0-2),(0-1520),("0E0","1E
1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E
4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
SIM7906_SIM7912 Series_AT Command Manual_V1.01
143
2019-11-21
Smart Machine Smart Decision
lF
ile
+CGEQMIN: "PPP",(0-4),(0-11520),(0-42200),(0-115200),(0-42200),(0-2),(0-1520),("0E0","1
E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1
E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
+CGEQMIN: "IPV6",(0-4),(0-11520),(0-42200),(0-115200),(0-42200),(0-2),(0-1520),("0E0","
1E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","
1E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
+CGEQMIN:"IPV4V6",(0-4),(0-11520),(0-42200),(0-115200),(0-42200),(0-2),(0-1520),("0E0","1E
1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4","1E5","
1E6","6E8"),(0-3),(0,100-4000),(0-3),(0-1),(0-1)
AT+CGDATA Enter data state
id
e
Description
nt
8.11
ia
OK
The command causes the MT to perform whatever actions are necessary to establish
communication between the TE and the network using one or more Packet Domain PDP types. This
may include performing a PS attach and one or more PDP context activations.
YES
References
C
on
f
SIM PIN
3GPP TS 27.007
Syntax
C
om
Test Command
AT+CGDATA=?
M
Write Command
AT+CGDATA=[<L2P>,[<ci
d>]]
Responses
+CGDATA: (list of supported <L2P>s)
OK
ERROR
Responses
CONNECT [<text>]
NO CARRIER
OK
ERROR
+CME ERROR: <err>
SI
Defined values
<L2P>
A string parameter that indicates the layer 2 protocol to be used between the TE and MT.
PPP
Point-to-point protocol for a PDP such as IP
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
144
2019-11-21
Smart Machine Smart Decision
lF
ile
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command).
1…24
Examples
AT+CGPADDR
Show PDP address
id
e
Description
nt
8.12
ia
AT+CGDATA=?
+CGDATA: ("PPP")
OK
AT+CGDATA="PPP",1
CONNECT 115200
The write command returns a list of PDP addresses for the specified context identifiers.
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+CGPADDR=?
C
on
f
SIM PIN
Responses
[+CGPADDR: (list of defined <cid>s)]
OK
ERROR
Responses
AT+CGPADDR=
<cid>[,<cid>[,…]]
[+CGPADDR:<cid>,<PDP_addr>[<CR><LF>
+CGPADDR: <cid>,<PDP_addr>[...]]]
OK
SI
M
C
om
Write Command
SIM card supports IPV4V6 type and the PDP_type of the command
“at+cgdcont” defined is ipv4v6 :
[+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6>]
+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6> [...]]]
OK
ERROR
+CME ERROR: <err>
Execution Command
Responses
AT+CGPADDR
[+CGPADDR: <cid>,<PDP_addr>]
+CGPADDR: <cid>,<PDP_addr>[...]]]
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
145
2019-11-21
Smart Machine Smart Decision
lF
ile
SIM card supports IPV4V6 type and the PDP_type of the command
“at+cgdcont” defined is ipv4v6 :
[+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6>]
+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6> [...]]]
OK
ERROR
+CME ERROR: <err>
Defined values
C
on
f
id
e
nt
ia
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command). If no <cid> is specified, the addresses for all defined contexts are returned.
1…24
<PDP_addr>
A string that identifies the MT in the address space applicable to the PDP. The address may be static
or dynamic. For a static address, it will be the one set by the AT+CGDCONT command when the
context was defined. For a dynamic address it will be the one assigned during the last PDP context
activation that used the context definition referred to by <cid>. <PDP_addr> is omitted if none is
available.
<PDP_addr_IPV4>
A string parameter that identifies the MT in the address space applicable to the PDP.
<PDP_addr_IPV6>
A string parameter that identifies the MT in the address space applicable to the PDP when the
sim_card supports ipv6. The pdp type must be set to “ipv6” or “ipv4v6” by the AT+CGDCONT
command.
C
om
Examples
SI
M
AT+CGPADDR =?
+CGPADDR: (1)
OK
AT+CGPADDR=1
+CGDCONT: 1,"IPV4V6","","0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0",0,0,0,0
OK
AT+CGPADDR
+CGPADDR: 1,10.195.1.140,36.9.136.148.128.48.134.218.173.205.47.44.88.174.123.200
+CGPADDR: 2,10.195.34.92,36.9.136.148.128.48.146.115.92.140.135.230.248.131.5.90
+CGPADDR: 3,0.0.0.0,0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
146
2019-11-21
Smart Machine Smart Decision
AT+CGCLASS
GPRS mobile station class
Description
lF
ile
8.13
This command is used to set the MT to operate according to the specified GPRS mobile class.
SIM PIN
YES
References
3GPP TS 27.007
Syntax
ia
Responses
+CGCLASS: (list of supported <class>s)
OK
ERROR
Responses
+CGCLASS: <class>
OK
ERROR
Responses
OK
C
on
f
Write Command
AT+CGCLASS=<class>
id
e
Read Command
AT+CGCLASS?
nt
Test Command
AT+CGCLASS=?
ERROR
Execution Command
AT+CGCLASS
+CME ERROR: <err>
Responses
Set default value:
OK
C
om
ERROR
Defined values
<class>
A string parameter which indicates the GPRS mobile class (in descending order of functionality)
A – class A (highest)
SI
M
Examples
AT+CGCLASS=?
+CGCLASS: ("A")
OK
AT+CGCLASS?
+CGCLASS: "A"
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
147
2019-11-21
Smart Machine Smart Decision
8.14
AT+CGEREP GPRS event reporting
lF
ile
Description
YES
References
3GPP TS 27.007
nt
SIM PIN
ia
The write command enables or disables sending of unsolicited result codes, “+CGEV” from MT to
TE in the case of certain events occurring in the Packet Domain MT or the network. <mode>
controls the processing of unsolicited result codes specified within this command. <bfr> controls
the effect on buffered codes when <mode> 1 or 2 is entered. If a setting is not supported by the MT,
ERROR or +CME ERROR: is returned.
Read command returns the current <mode> and buffer settings.
Test command returns the modes and buffer settings supported by the MT as compound values.
Test Command
AT+CGEREP=?
Responses
+CGEREP: (list of supported <mode>s),(list of supported <bfr>s)
OK
C
on
f
ERROR
Read Command
AT+CGEREP?
id
e
Syntax
Responses
+CGEREP: <mode>,<bfr>
OK
ERROR
C
om
Write Command
AT+CGEREP=
<mode>[,<bfr>]
Execution Command
AT+CGEREP
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
SI
M
Defined values
<mode>
0 – buffer unsolicited result codes in the MT; if MT result code buffer is full, the oldest
ones can be discarded. No codes are forwarded to the TE.
1 – discard unsolicited result codes when MT-TE link is reserved (e.g. in on-line data
mode); otherwise forward them directly to the TE.
2 – buffer unsolicited result codes in the MT when MT-TE link is reserved (e.g. in on-line
data mode) and flush them to the TE when MT-TE link becomes available; otherwise
forward them directly to the TE.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
148
2019-11-21
Smart Machine Smart Decision
<bfr>
0
C
om
C
on
f
id
e
nt
ia
lF
ile
– MT buffer of unsolicited result codes defined within this command is cleared when
<mode> 1 or 2 is entered.
1 – MT buffer of unsolicited result codes defined within this command is flushed to the TE
when <mode> 1 or 2 is entered (OK response shall be given before flushing the codes).
The following unsolicited result codes and the corresponding events are defined:
+CGEV: REJECT <PDP_type>, <PDP_addr>
A network request for PDP context activation occurred when the MT was unable to
report it to the TE with a +CRING unsolicited result code and was automatically
rejected.
+CGEV: NW REACT <PDP_type>, <PDP_addr>, [<cid>]
The network has requested a context reactivation. The <cid> that was used to reactivate
the context is provided if known to the MT.
+CGEV: NW DEACT <PDP_type>, <PDP_addr>, [<cid>]
The network has forced a context deactivation. The <cid> that was used to activate the
context is provided if known to the MT.
+CGEV: ME DEACT <PDP_type>, <PDP_addr>, [<cid>]
The mobile equipment has forced a context deactivation. The <cid> that was used to
activate the context is provided if known to the MT.
+CGEV: NW DETACH
The network has forced a Packet Domain detach. This implies that all active contexts
have been deactivated. These are not reported separately.
+CGEV: ME DETACH
The mobile equipment has forced a Packet Domain detach. This implies that all active
contexts have been deactivated. These are not reported separately.
+CGEV: NW CLASS <class>
The network has forced a change of MS class. The highest available class is reported
(see AT+CGCLASS).
+CGEV: ME CLASS <class>
The mobile equipment has forced a change of MS class. The highest available class is
reported (see AT+CGCLASS).
Examples
SI
M
AT+CGEREP=?
+CGEREP: (0-2),(0-1)
OK
AT+CGEREP?
+CGEREP: 0,0
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
149
2019-11-21
Smart Machine Smart Decision
8.15
AT+CGAUTH
Set type of authentication for PDP-IP connections of
lF
ile
GPRS
Description
This command is used to set type of authentication for PDP-IP connections of GPRS.
YES
References
Vendor
ia
SIM PIN
Syntax
Responses
AT+CGAUTH=?
+CGAUTH:(range of supported <cid>s),(list of supported <auth_type> s),127,127
ERROR
id
e
OK
nt
Test Command
+CME ERROR: <err>
AT+CGAUTH?
Responses
C
on
f
Read Command
+CGAUTH:[ <cid>,<auth_type>[,<user>,<passwd>]]<CR><LF>
…
OK
ERROR
+CME ERROR: <err>
Write Command
Responses
OK
Execution Command
Responses
AT+CGAUTH
OK
ERROR
ERROR
+CME ERROR: <err>
M
C
om
AT+CGAUTH=<cid>[,<aut
h_type>[,<passwd>[,<user>]
]]
SI
Defined values
<cid>
Parameter specifies a particular PDP context definition. This is also used in other PDP
context-related commands.
1…24
<auth_type>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
150
2019-11-21
Smart Machine Smart Decision
ia
lF
ile
Indicate the type of authentication to be used for the specified context. If CHAP is selected another
parameter <passwd> needs to be specified. If PAP is selected two additional parameters <passwd>
and <user> need to specified.
0 – none
1 – PAP
2 – CHAP
3 – PAP or CHAP
<passwd>
Parameter specifies the password used for authentication.
<user>
Parameter specifies the user name used for authentication.
nt
Examples
SI
M
C
om
C
on
f
OK
AT+CGAUTH=1,1,”123”,”SIMCOM”
OK
id
e
AT+CGAUTH=?
+CGAUTH: (1-24),(0-3),127,127
SIM7906_SIM7912 Series_AT Command Manual_V1.01
151
2019-11-21
Smart Machine Smart Decision
9.1
AT Commands for SIM Application Toolkit
lF
ile
9
AT+STIN SAT Indication
Description
YES
References
Vendor
Syntax
Read Command
AT+STIN?
Responses
OK
C
on
f
Test Command
AT+STIN=?
id
e
SIM PIN
nt
ia
Every time the SIM Application issues a Proactive Command, via the ME, the TA will receive an
indication. This indicates the type of Proactive Command issued.
AT+STGI must then be used by the TA to request the parameters of the Proactive Command from
the ME. Upon receiving the +STGI response from the ME, the TA must send AT+STGR to confirm
the execution of the Proactive Command and provide any required user response, e.g. a selected
menu item.
Responses
+STIN: <cmd_id>
OK
C
om
Unsolicited Result Codes
SI
M
+STIN: <cmd_id>
Proactive Command notification
21 – display text
22
– get inkey
23
– get input
24
– select item
+STIN: 25
Notification that SIM Application has returned to main menu. If user doesn’t do any action in 2
minutes, application will return to main menu automatically.
Defined values
<cmd_id>
21 – display text
22
– get inkey
SIM7906_SIM7912 Series_AT Command Manual_V1.01
152
2019-11-21
Smart Machine Smart Decision
–
–
–
–
–
get input
select item
set up menu
session end (pdu mode only)
none command
lF
ile
23
24
25
81
0
Examples
AT+STGI Get SAT information
nt
9.2
ia
AT+STIN?
+STIN: 24
OK
Description
SIM PIN
YES
C
on
f
id
e
Regularly this command is used upon receipt of an URC "+STIN" to request the parameters of the
Proactive Command. Then the TA is expected to acknowledge the AT+STGI response with
AT+STGR to confirm that the Proactive Command has been executed. AT+STGR will also provide
any user information, e.g. a selected menu item. The Proactive Command type value specifies to
which "+STIN" the command is related.
NOTE: Please check the format referred to AT+STKFMT
References
Vendor
Syntax
C
om
Test Command
AT+STGI=?
Write Command
Responses
AT+STGI=<cmd_id>
PDU format
+STGI: <cmd_id>,<tag>,<pdu_len>,<pdu_value>
OK
AT+STGI=<cmd_id>
NOT PDU format, listed below:
If <cmd_id>=10:
OK
M
SI
Responses
OK
If <cmd_id>=21:
+STGI:21,<prio>,<clear_mode>,<text_len>,<text>
OK
If <cmd_id>=22:
+STGI: 22,< rsp_format>,< help>,<text_len>,<text>
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
153
2019-11-21
Smart Machine Smart Decision
lF
ile
If <cmd_id>=23:
+STGI:23,<rsp_format>,<max_len>,<min_len>,<help>,<show>,<t
ext_len>,<text>
OK
ia
If <cmd_id>=24:
+STGI:24,<help>,<softkey>,<present>,<title_len>,<title>,<item_n
um>
+STGI:24,<item_id>,<item_len>,<item_data>
[…]
OK
Defined values
SI
M
C
om
C
on
f
<cmd_id>
21 – display text
22
– get inkey
23
– get input
24
– select item
25
– set up menu
<prio>
Priority of display text
0 – Normal priority
1 – High priority
<clear_mode>
0 – Clear after a delay
1
– Clear by user
<text_len>
Length of text
<rsp_format>
0 – SMS default alphabet
1
– YES or NO
2 – numerical only
3
– UCS2
<help>
0 – Help unavailable
1
– Help available
<max_len>
Maximum length of input
id
e
nt
If <cmd_id>=25:
+STGI:25,<help>,<softkey>,<title_len>,<title>,<item_num>
+STGI:25,<item_id>,<item_len>,<item_data>
[...]
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
154
2019-11-21
ia
nt
C
om
C
on
f
id
e
<min_len>
Minimum length of input
<show>
0 – Hide input text
1
– Display input text
<softkey>
0 – No softkey preferred
1
– Softkey preferred
<present>
Menu presentation format available for select item
0 – Presentation not specified
1
– Data value presentation
2 – Navigation presentation
<title_len>
Length of title
<item_num>
Number of items in the menu
<item_id>
Identifier of item
<item_len>
Length of item
<title>
Title in ucs2 format
<item_data>
Content of the item in ucs2 format
<text>
Text in ucs2 format.
<tag>
Not used now.
<pdu_len>
Integer type, pdu string length
<pdu_value>
String type, the pdu string.
lF
ile
Smart Machine Smart Decision
SI
M
Examples
AT+STGI=25 (NOT PDU format)
+STGI:25,0,0,10,"795E5DDE884C59295730",15
+STGI:25,1,8,"8F7B677E95EE5019"
+STGI:25,2,8,"77ED4FE17FA453D1"
+STGI:25,3,8,"4F1860E05FEB8BAF"
+STGI:25,4,8,"4E1A52A17CBE9009"
+STGI:25,5,8,"8D448D3963A88350"
SIM7906_SIM7912 Series_AT Command Manual_V1.01
155
2019-11-21
Smart Machine Smart Decision
9.3
AT+STGR SAT respond
Description
id
e
nt
ia
lF
ile
+STGI:25,6,8,"81EA52A9670D52A1"
+STGI:25,7,8,"8F7B677E5F6994C3"
+STGI:25,8,8,"8BED97F367425FD7"
+STGI:25,9,10,"97F34E506392884C699C"
+STGI:25,10,8,"65B095FB59296C14"
+STGI:25,11,8,"94C358F056FE7247"
+STGI:25,12,8,"804A59294EA453CB"
+STGI:25,13,8,"5F005FC34F1195F2"
+STGI:25,14,8,"751F6D3B5E388BC6"
+STGI:25,21,12,"00530049004D53614FE1606F"
OK
AT+STGI=24 (PDU format)
+STGI:24,0,48,"D02E81030124008202818285098070ED70B963A883508F0A018053057F574E0
78C618F0C02809177917777ED6D88606F"
OK
SIM PIN
YES
C
on
f
The TA is expected to acknowledge the AT+STGI response with AT+STGR to confirm that the
Proactive Command has been executed. AT+STGR will also provide any user information, e.g. a
selected menu item.
NOTE: Please check the format referred to AT+STKFMT
References
Vendor
C
om
Syntax
Responses
AT+STGR=?
OK
Write Command
Responses
AT+STGR=<cmd_id>[,<dat
a>]
NOT PDU format
OK
M
Test Command
SI
AT+STGR=<pdu_len>,<pdu
_value>
PDU format
OK
Defined values
<cmd_id>
22
– get inkey
23
– get input
SIM7906_SIM7912 Series_AT Command Manual_V1.01
156
2019-11-21
Smart Machine Smart Decision
C
om
C
on
f
id
e
nt
ia
lF
ile
24
– select item
25 – set up menu
81 – session end
83 – session end by user
84
– go backward
<data>
If <cmd_id>=22:
Input a character
If <cmd_id>=23:
Input a string.
If <rsp_format> is YES or NO, input of a character in case of ANSI character set requests one
byte, e.g. “Y”.
If <rsp_format> is numerical only, input the characters in decimal number, e.g. “123”
If <rsp_faomat> is UCS2, requests a 4 byte string, e.g. “0031”
<rsp_faomat> refer to the response by AT+STGI=23
If <cmd_id>=24:
Input the identifier of the item selected by user
If <cmd_id>=25:
Input the identifier of the item selected by user
If <cmd_id>=83:
<data> ignore
Note: It could return main menu during Proactive Command id is not 22 or 23
If <cmd_id>= 84:
<data> ignore
<pdu_len>
Integer type, pdu string length
<pdu_value>
String type, the pdu string.
Examples
M
AT+STGR=25,1
(NOT PDU format)
OK
+STIN: 24
AT+STGR=30,"810301240002028281830100900101" (PDU format)
OK
SI
9.4
AT+STK STK switch
Description
This command is used to disable or enable the STK function. If the argument is 1, it is enabled.
While if the argument is 0, it is disabled.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
157
2019-11-21
Smart Machine Smart Decision
SIM PIN
NO
References
Vendor
Test Command
AT+STK=?
lF
ile
Syntax
Responses
+STK: (list of supported <value>s)
Responses
+STK: <value>
OK
Write Command
AT+STK=<value>
Responses
OK
nt
Read Command
AT+STK?
Responses
Set default value (<value>=0):
OK
C
on
f
Defined values
id
e
ERROR
Execution Command
AT+STK
ia
OK
<value>
0 – Disable STK
1 – Enable STK
Examples
C
om
AT+STK=1
OK
9.5
AT+STKFMT Set STK pdu format
Description
SI
M
This command is used to disable or enable the STK pdu mode. If the argument is 1, it is enabled.
While if the argument is 0, it is disabled.
NOTE: Module should reboot to take effective.
SIM PIN
YES
References
Vendor
Syntax
Read Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
158
2019-11-21
AT+STKFMT?
+STKFMT: <value>
OK
Write Command
AT+STKFMT=<value>
Responses
OK
lF
ile
Smart Machine Smart Decision
ERROR
Defined values
nt
Examples
id
e
AT+STKFMT=1
OK
AT+STENV Original STK PDU Envelope Command
Description
C
on
f
9.6
ia
<value>
0 – Disable STK pdu format, decoded command mode.
1 – Enable STK pdu format
This command is used to original stk pdu envelope command.
NOTE: PDU format supported only.
SIM PIN
YES
References
Vendor
C
om
Syntax
Responses
OK
Write Command
AT+STENV=<len>,<pdu>
Responses
OK
M
Test Command
AT+STENV=?
ERROR
SI
Defined values
<len>
Integer type, pdu string length
<pdu>
String type, pdu value
SIM7906_SIM7912 Series_AT Command Manual_V1.01
159
2019-11-21
Smart Machine Smart Decision
Examples
9.7
lF
ile
AT+STENV=18,"D30782020181900101"
OK
AT+STSM Get STK Setup Menu List with PDU Mode
Description
YES
References
Vendor
nt
SIM PIN
ia
This command is used to get the stk setup menu list with pdu mode
NOTE: PDU format supported only.
id
e
Syntax
Responses
OK
Read Command
AT+STSM?
Responses
+STSM: <cmd_id>,<tag>,<pdu_len>, <pdu_value>
OK
C
on
f
Test Command
AT+STSM=?
ERROR
Defined values
C
om
<cmd_id>
Integer type, please refer to AT+STIN
<tag>
Not used now.
<pdu_len>
Integer type, pdu string length
<pdu_value>
String type, the pdu string.
SI
M
Examples
AT+STSM?
+STSM:25,0,120,"D07681030125008202818285078065B052BF529B8F0A018070ED70B963A883
508F06028070AB94C38F0A03806D41884C77ED4FE18F0A048081EA52A9670D52A18F0A0580
624B673A97F34E508F0606808D854FE18F0A07805A314E50753162118F0A0880767E53D8751F
6D3B8F0A09806D596C5F98919053"
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
160
2019-11-21
Smart Machine Smart Decision
10.1
AT+CFTRANRX
lF
ile
10 AT Commands for File Transmission
Transfer a file to EFS
Description
This command is used to transfer a file to EFS. Support SD card.
ia
NO
References
Vendor
nt
SIM PIN
Syntax
AT+CFTRANRX=“<filepat
h>”,<len>
>
OK
id
e
Write Command
Responses
+CFTRANRX: [{non-ascii}]"FILEPATH"
OK
Responses
C
on
f
Test Command
AT+CFTRANRX=?
>
ERROR
ERROR
Defined values
C
om
<filepath>
The path of the file on EFS.
<len>
The length of the file data to send.
NOTE
The <filepath> must be a full path with the directory path.
SI
M
Examples
AT+CFTRANRX=”c:/MyDir/t1.txt”,10
>testcontent
OK
AT+CFTRANRX=”d:/MyDir/t1.txt”,10
>testcontent
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
161
2019-11-21
Smart Machine Smart Decision
10.2
AT+CFTRANTX Transfer a file from EFS to host
lF
ile
Description
This command is used to transfer a file from EFS to host. Before using this command, the
AT+CATR must be used to set the correct port used. Support SD card.
SIM PIN References
NO
Vendor
Responses
+CFTRANTX: [{non-ascii}]"FILEPATH"
OK
Responses
Write Command
[+CFTRANTX: DATA,<len>
…
+CFTRANTX: DATA,<len>]
+CFTRANTX: 0
OK
C
on
f
AT+CFTRANTX=“<filepath
>”[,<location>,<size>]
id
e
nt
Test Command
AT+CFTRANTX=?
ia
Syntax
ERROR
Defined values
SI
M
C
om
<filepath>
The path of the file on EFS.
<len>
The length of the following file data to output.
<location>
The beginning of the file data to output.
<size>
The length of the file data to output.
NOTE
1. The <filepath> must be a full path with the directory path.
2. When the number of digits in <len> is less than three digits, 0 will be padded in front of <len> to
form three digits.
3. When <len> is greater than 512, the data will be output in 512 bytes per packet.
Examples
AT+CFTRANTX=”c:/MyDir/t1.txt”
+CFTRANTX: DATA, 011
Testcontent
SIM7906_SIM7912 Series_AT Command Manual_V1.01
162
2019-11-21
Smart Machine Smart Decision
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
+CFTRANTX: 0
OK
AT+CFTRANTX=”d:/MyDir/t1.txt”
+CFTRANTX: DATA, 011
Testcontent
+CFTRANTX: 0
OK
AT+CFTRANTX=”d:/MyDir/t1.txt”,1,4
+CFTRANTX: DATA, 004
estc
+CFTRANTX: 0
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
163
2019-11-21
Smart Machine Smart Decision
11.1
lF
ile
11 AT Commands for Open/Close Network
AT+CNETSTART Open network
Description
This command opens packet network.
ia
YES
References
Vendor
nt
SIM PIN
Syntax
Responses
+CNETSTART: <net_state>
OK
C
on
f
ERROR
id
e
Read Command
AT+CNETSTART?
Execution Command
AT+CNETSTART
Responses
OK
+CNETSTART: <err>
C
om
+CNETSTART: <err>
OK
+CNETSTART: <err>
ERROR
ERROR
SI
M
Defined values
<net_state>
a numeric parameter that indicates the state of PDP context activation:
0
network close (deactivated)
1 network is opening
2 network open(activated)
3 network is closing
<err >
SIM7906_SIM7912 Series_AT Command Manual_V1.01
164
2019-11-21
Smart Machine Smart Decision
The result of operation, 0 is success, other value is failure.
Examples
lF
ile
AT+CNETSTART
OK
ia
+CNETSTART: 0
AT+CNETSTART?
+CNETSTART: 2
AT+CNETSTOP Close network
id
e
11.2
nt
OK
Description
This command closes network. Before calling this command, all opened sockets must be closed
first.
YES
References
C
on
f
SIM PIN
Vendor
Syntax
SI
M
C
om
Execution Command
AT+CNETSTOP
Responses
OK
+CNETSTOP: <err>
+CNETSTOP: <err>
OK
+CNETSTOP: <err>
ERROR
ERROR
Defined values
<err>
The result of operation, 0 is success, other value is failure.
Examples
SIM7906_SIM7912 Series_AT Command Manual_V1.01
165
2019-11-21
Smart Machine Smart Decision
AT+CNETSTOP
OK
11.3
lF
ile
+CNETSTOP: 0
AT+CNETIPADDR Inquire PDP address
Description
This command inquires the IP address of current active PDP.
ia
YES
References
Vendor
nt
SIM PIN
Syntax
Responses
+CNETIPADDR: < ip_address>
OK
id
e
Read Command
AT+CNETIPADDR?
C
on
f
+CNETIPADDR: <err_info>
ERROR
ERROR
Defined values
C
om
<ip_address>
A string parameter that identifies the IP address of current active socket PDP.
<err_info>
A string parameter that displays the cause of occurring error.
Examples
M
AT+CNETIPADDR?
+CNETIPADDR: 10.71.155.118
SI
OK
11.4
Unsolicited Open/Close network command <err> Codes
Code of <err>
0
Description
Operation succeeded
SIM7906_SIM7912 Series_AT Command Manual_V1.01
166
2019-11-21
Unknown error
Open network failed
3
4
5
6
7
8
Close network failed
Network not opened
Operation not support
Busy
Network has been opened
Network is also in use
SI
M
C
om
C
on
f
id
e
nt
ia
1
2
lF
ile
Smart Machine Smart Decision
SIM7906_SIM7912 Series_AT Command Manual_V1.01
167
2019-11-21
Smart Machine Smart Decision
12.1
AT+CGPS
lF
ile
12 AT Commands for GPS
Start/Stop GPS session
Description
SIM PIN
NO
C
on
f
id
e
nt
ia
This command is used to start or stop GPS session.
NOTE:
1. Output of NMEA sentences is automatic; no control via AT commands is provided. At
present the module only supports standalone mode. If executing AT+CGPS=1, the GPS
session will choose cold or hot start automatically.
2. UE-based and UE-assisted mode depend on URL (AT+CGPSURL). When UE-based
mode fails, it will switch standalone mode.
3. UE-assisted mode is singly fixed. Standalone and UE-based mode is consecutively
fixed.
4. After the GPS closed, it should to wait about 2s~30s for start again. Reason:If the
signal conditions are right (strong enough signals to allow ephemeris demodulation) or
ephemeris demodulation is on going, sometimes MGP will stay on longer in order to
demodulate more ephemeris. This will help the engine provide faster TTFF and
possibly better yield later (up to 2 hours), because it has the benefit of more ephemeris
available.
References
Vendor
C
om
Syntax
Responses
+CGPS: (list of supported <on/off>s),( list of supported <mode>s)
OK
Read Command
AT+CGPS?
Responses
+CGPS: <on/off>,<mode>
OK
SI
M
Test Command
AT+CGPS=?
Write Command
AT+CGPS=<on/off>
[,<mode>]
Responses
OK
If UE-assisted mode, when fixed will report indication:
+CAGPSINFO:<lat>,<lon>,<alt>,<date>,<time>
If <off>, it will report indication:
+CGPS: 0
ERROR
SIM7906_SIM7912 Series_AT Command Manual_V1.01
168
2019-11-21
Smart Machine Smart Decision
Examples
C
om
AT+CGPS?
OK
AT+CGPS=1,1
OK
C
on
f
id
e
nt
ia
<on/off>
0 – stop GPS session
1 – start GPS session
<mode>
Ignore - standalone mode
1 – standalone mode
2 – UE-based mode
3 – UE-assisted mode
<lat>
Latitude of current position. Unit is in 10^8 degree
<log>
Longitude of current position. Unit is in 10^8 degree
<alt>
MSL Altitude. Unit is meters.
<date>
UTC Date. Output format is ddmmyyyy
<time>
UTC Time. Output format is hhmmss.s
< unconfidence >
Unconfidence of the location, GPS fixed report 39, cell fixed report 100.
< uncertainty_meter >
Uncertainty meters.
lF
ile
Defined values
12.2
AT+CGPSINFO
Get GPS fixed position information
M
Description
This command is used to get current position information.
SI
SIM PIN
NO
References
Vendor
Syntax
Test Command
AT+CGPSINFO=?
Responses
+CCGPSINFO: (scope of <time>)
SIM7906_SIM7912 Series_AT Command Manual_V1.01
169
2019-11-21
Smart Machine Smart Decision
OK
Responses
AT+CGPSINFO?
+CCGPSINFO: <time>
OK
Write Command
AT+CGPSINFO=<time>
Responses
OK
+CGPSINFO: [<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC
time>],[<alt>],[<speed>],[<course>]
lF
ile
Read Command
OK (if <time>=0)
ia
Responses
+CGPSINFO: [<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC
time>],[<alt>],[<speed>],[<course>]
OK
nt
Execution Command
AT+CGPSINFO
id
e
Defined values
SI
M
C
om
C
on
f
<lat>
Latitude of current position. Output format is ddmm.mmmmmm
<N/S>
N/S Indicator, N=north or S=south
<log>
Longitude of current position. Output format is dddmm.mmmmmm
<E/W>
E/W Indicator, E=east or W=west
<date>
Date. Output format is ddmmyy
<UTC time>
UTC Time. Output format is hhmmss.s
<alt>
MSL Altitude. Unit is meters.
<speed>
Speed Over Ground. Unit is knots.
<course>
Course. Degrees.
<time>
The range is 0-255, unit is second, after set <time> will report the GPS information every the
seconds.
Examples
AT+CGPSINFO=?
+CGPSINFO: (0-255)
SIM7906_SIM7912 Series_AT Command Manual_V1.01
170
2019-11-21
OK
AT+CGPSINFO?
+CGPSINFO: 0
OK
AT+CGPSINFO
+CGPSINFO:3113.343286,N,12121.234064,E,250311,072809.3,44.1,0.0,0
OK
AT+CGPSCOLD Cold start GPS
ia
12.3
lF
ile
Smart Machine Smart Decision
Description
NO
References
Vendor
Syntax
Responses
OK
Responses
OK
C
on
f
Test Command
AT+CGPSCOLD=?
Execution Command
AT+CGPSCOLD
id
e
SIM PIN
nt
This command is used to cold start GPS session.
NOTE: Before using this command,it must use AT+CGPS=0 to stop GPS session.
Examples
C
om
AT+CGPSCOLD=?
OK
AT+CGPSCOLD
OK
12.4
AT+CGPSHOT Hot start GPS
Description
M
This command is used to hot start GPS session
NOTE: Before using this command, AT+CGPS=0 must be used to stop GPS session.
SI
SIM PIN
NO
References
Vendor
Syntax
Test Command
AT+CGPSHOT=?
Responses
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
171
2019-11-21
Smart Machine Smart Decision
Execution Command
AT+CGPSHOT
Responses
OK
lF
ile
Examples
12.5
AT+CGPSURL Set AGPS default server URL
nt
Description
ia
AT+CGPSHOT=?
OK
AT+CGPSHOT
OK
This command is used to set AGPS default server URL. It will take effect only after restarting.
NO
References
id
e
SIM PIN
Vendor
Test Command
AT+CGPSURL=?
Read Command
AT+CGPSURL?
C
on
f
Syntax
C
om
Write Command
AT+CGPSURL=<URL>
Responses
OK
Responses
+CGPSURL: <URL>
OK
Responses
OK
ERROR
Defined values
<URL>
AGPS default server URL. It needs double quotation marks.
SI
M
Examples
AT+CGPSURL=”123.123.123.123:8888”
OK
AT+CGPSURL?
+CGPSURL: ”123.123.123.123:8888”
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
172
2019-11-21
Smart Machine Smart Decision
12.6
AT+CGPSSSL Set AGPS transport security
lF
ile
Description
This command is used to select transport security, used certificate or not. The certificate gets from
local carrier. If the AGPS server doesn’t need certificate, execute AT+CGPSSSL=0.
SIM PIN
References
NO
Vendor
ia
Syntax
Responses
+CGPSSSL: (list of supported <SSL>s)
OK
Read Command
AT+CGPSSSL?
Responses
+CGPSSSL: <SSL>
OK
Write Command
Responses
AT+CGPSSSL=<SSL>
OK
C
on
f
id
e
nt
Test Command
AT+CGPSSSL=?
ERROR
Defined values
– don’t use certificate
– use certificate
C
om
<SSL>
0
1
Examples
AT+CGPSSSL=0
OK
AT+CGPSAUTO
Start GPS automatic
M
12.7
SI
Description
This command is used to start GPS automaticly when module powers on, GPS is closed defaultly.
NOTE: If GPS start automatically, its operation mode is standalone mode.
SIM PIN
NO
References
Vendor
Syntax
SIM7906_SIM7912 Series_AT Command Manual_V1.01
173
2019-11-21
Smart Machine Smart Decision
Responses
+CGPSAUTO:( list of supported <auto>s)
OK
Read Command
AT+CGPSAUTO?
Responses
+CGPSAUTO:<auto>
OK
Responses
OK
Write Command
AT+CGPSAUTO=<auto>
lF
ile
Test Command
AT+CGPSAUTO=?
ia
ERROR
– Non-automatic
– automatic
id
e
<auto>
0
1
nt
Defined values
Examples
12.8
C
on
f
AT+CGPSAUTO=1
OK
AT+CGPSNMEA Configure NMEA sentence type
Description
C
om
This command is used to configure NMEA output sentences which are generated by the gpsOne
engine when position data is available.
NOTE: If nmea bit 2 GPGSV doesn’t configure, GPGSV sentence also doesn’t output on
AT/modem port even set AT+CGPSFTM=1.
Module should reboot to take effect.
SIM PIN
NO
References
Vendor
SI
M
Syntax
Test Command
AT+CGPSNMEA=?
Responses
+CGPSNMEA: (scope of <nmea>)
OK
Read Command
AT+CGPSNMEA?
Responses
+CGPSNMEA: <nmea>
OK
Write Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
174
2019-11-21
Smart Machine Smart Decision
AT+CGPSNMEA=<nmea>
OK
lF
ile
If GPS engine is running:
ERROR
Defined values
C
om
C
on
f
id
e
nt
ia
<nmea>
Range – 0 to 262143
Each bit enables an NMEA sentence output as follows:
Bit 0 – GPGGA (global positioning system fix data)
Bit 1 – GPRMC (recommended minimum specific GPS/TRANSIT data)
Bit 2 – GPGSV (GPS satellites in view)
Bit 3 – GPGSA (GPS DOP and active satellites)
Bit 4 – GPVTG (track made good and ground speed)
Bit 5 – PQXFI (Global Positioning System Extended Fix Data.)
Bit 6 – GLGSV (GLONASS satellites in view GLONASS fixes only)
Bit 7 – GNGSA (1. GPS/2. Glonass/3. GALILE DOP and Active Satellites.)
Bit 8 – GNGNS (fix data for GNSS receivers;output for GPS,GLONASS,GALILEO)
Bit 9 – Reserved
Bit 10 – GAGSV (GALILEO satellites in view)
Bit 11 –Reserved
Bit 12 –Reserved
Bit 13 –Reserved
Bit 14 –Reserved
Bit 15 –Reserved,
Bit 16 –BDGSA/PQGSA (BEIDOU/QZSS DOP and active satellites)
Bit 17 –BDGSV/PQGSV (BEIDOUQZSS satellites in view)
Set the desired NMEA sentence bit(s). If multiple NMEA sentence formats are desired, “OR” the
desired bits together.
NOTE: Reserved default 0, set invalid.
Examples
M
AT+CGPSNMEA=200191
OK
AT+CGPSNEMARATE
Set NMEA output rate
SI
12.9
Description
This command is used to set nmea output rate
NOTE: send the command before open gps
SIM7906_SIM7912 Series_AT Command Manual_V1.01
175
2019-11-21
Smart Machine Smart Decision
NO
References
Vendor
Syntax
Responses
+CGPSNMEARATE: (scope of < rate >)
OK
Read Command
AT+CGPSNMEARATE?
Responses
+CGPSNMEARATE: <rate>
OK
Write Command
AT+CGPSNMEARATE=<r
ate>
Responses
OK
nt
C
on
f
<rate>
0
output rate 1HZ
1
output rate 10HZ
ERROR
id
e
Defined values
ia
Test Command
AT+CGPSNMEARATE=?
lF
ile
SIM PIN
Examples
AT+CGPSNMEARATE =1
OK
C
om
12.10 AT+CGPSMD Configure AGPS MO method
Description
This command specifies if the Mobile-Originated (MO) GPS session should use the control plane
session or user plane session.
SIM PIN
Vendor
M
NO
References
SI
Syntax
Test Command
AT+CGPSMD=?
Responses
+CGPSMD: (scope of <method>)
OK
Read Command
AT+CGPSMD?
Responses
+CGPSMD: <method>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
176
2019-11-21
Smart Machine Smart Decision
OK
Write Command
Responses
AT+CGPSMD=<method>
OK
lF
ile
If GPS engine is running:
ERROR
Defined values
ia
<method>
0 – Control plane
1 – User plane
nt
Examples
12.11 AT+CGPSFTM
Start GPS test mode
C
on
f
Description
id
e
AT+CGPSMD=1
OK
C
om
This command is used to start GPS test mode.
NOTE:
1. If test mode starts, the URC will report on AT port, Modem port and UART port.
2. If testing on actual signal, <SV> should be ignored, and GPS must be started by AT+CGPS,
AT+CGPSCOLD or AT+CGPSHOT.
3. If testing on GPS signal simulate equipment, <SV> must be choiced, and GPS will start
automatically.
4. URC sentence will report every 1 second.
SIM PIN
NO
References
Vendor
Syntax
Responses
OK
Read Command
AT+CGPSFTM?
Responses
+CGPSFTM: <on/off>
OK
Responses
OK
SI
M
Test Command
AT+CGPSFTM=?
Write Command
AT+CGPSFTM=<on/off>
ERROR
SIM7906_SIM7912 Series_AT Command Manual_V1.01
177
2019-11-21
Smart Machine Smart Decision
Defined values
Examples
id
e
AT+CGPSFTM=1
OK
$GLGSV,78,20.6,66,25.6,77,21.6,79,21.9,67,26.2,68,23.6
nt
ia
lF
ile
<on/off>
0 – Close test mode
1 – Start test mode
<CNo>
Satellite CNo value. Floating value.
URC format
$GPGSV[,<SV>,<CNo>][...]
$GLGSV[,<SV>,<CNo>][...]
$BDGSV[,<SV>,<CNo>][...]
$GAGSV[,<SV>,<CNo>][...]
$PQGSV[,<SV>,<CNo>][...]
C
on
f
$GPGSV,10,36.3,12,33.5,14,26.5,15,27.0,18,30.6,20,29.4,21,14.9,24,32.8,25,30.6,31,29.1,32,27.0
$BDGSV,201,28.7,204,29.0,206,27.3,207,25.9,209,25.0,210,18.5
12.12 AT+CGPSDEL Delete the GPS information
Description
C
om
This command is used to delete the GPS information. After executing the command, GPS start is
cold start.
NOTE: This command must be executed after GPS stopped.
SIM PIN
NO
References
Vendor
SI
M
Syntax
Test Command
AT+CGPSDEL=?
Responses
OK
Execution Command
AT+CGPSDEL
Responses
OK
ERROR
Examples
SIM7906_SIM7912 Series_AT Command Manual_V1.01
178
2019-11-21
AT+CGPSDEL=?
OK
AT+CGPSDEL
OK
12.13 AT+CGPSXE
Enable/Disable GPS XTRA function
Description
lF
ile
Smart Machine Smart Decision
NO
References
Vendor
id
e
SIM PIN
nt
ia
This command is used to enable/disable the GPS XTRA function.
NOTE: XTRA function must download the assistant file from network by HTTP, so the APN must
be set by AT+CGDCONT command.
Syntax
Read Command
AT+CGPSXE?
Responses
+CGPSXE: (list of supported <on/off>s)
OK
C
on
f
Test Command
AT+CGPSXE=?
Responses
+CGPSXE: <on/off>
OK
C
om
Write Command
AT+CGPSXE=<on/off>
Responses
OK
ERROR
Defined values
M
<on/off>
0 – Disable GPS XTRA
1 – Enable GPS XTRA
SI
Examples
AT+CGPSXE=?
+CGPSXE: (0,1)
OK
AT+CGPSXE=0
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
179
2019-11-21
Smart Machine Smart Decision
12.14 AT+CGPSXD
Download XTRA assistant file
lF
ile
Description
This command is used to download the GPS XTRA assistant file from network through http
protocol. Module will download the latest assistant file form server and write the file into module.
SIM PIN
NO
References
Vendor
ia
Syntax
Responses
+CGPSXD: (list of supported <server>s)
OK
Read Command
AT+CGPSXD?
Responses
+CGPSXD: <server>
OK
Write Command
AT+CGPSXD=<server>
Responses
OK
+CGPSXD: <resp>
C
on
f
id
e
nt
Test Command
AT+CGPSXD=?
+CGPSXD: <resp>
ERROR
Defined values
C
om
<server>
0 – XTRA primary server (precedence)
1 – XTRA secondary server
2 – XTRA tertiary server
<resp>
refer to Unsolicited XTRA download Codes
Examples
SI
M
AT+CGPSXD=?
+CGPSXD: (0-2)
OK
AT+CGPSXD=0
OK
+CGPSXD: 0
SIM7906_SIM7912 Series_AT Command Manual_V1.01
180
2019-11-21
Smart Machine Smart Decision
12.15 AT+CGPSXDAUTO Download XTRA assistant file automatically
lF
ile
Description
This command is used to control download assistant file automatically or not when GPS start.
XTRA function must enable for using this command. If assistant file doesn’t exist or check error,
the module will download and inject the assistant file automatically.
NO
References
Vendor
ia
SIM PIN
Syntax
Responses
+CGPSXDAUTO: (list of supported <on/off>s)
OK
Read Command
AT+CGPSXDAUTO?
Responses
+CGPSXDAUTO: <on/off>
OK
Write Command
AT+CGPSXDAUTO=<on/o
ff>
Responses
OK
id
e
C
on
f
Defined values
nt
Test Command
AT+CGPSXDAUTO=?
ERROR
C
om
<on/off>
0 – disable download automatically
1 – enable download automatically
NOTE: Some URCs will report when downloading, it’s same as AT+CGPSXD command.
Examples
SI
M
AT+CGPSXDAUTO=?
+CGPSXDAUTO: (0,1)
OK
AT+CGPSXDAUTO=0
OK
12.16 AT+CGPSINFOCFG Report GPS NMEA-0183 sentence
Description
This command is used to report NMEA-0183 sentence.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
181
2019-11-21
Smart Machine Smart Decision
SIM PIN
NO
References
Vendor
lF
ile
Syntax
Responses
+CGPSINFOCFG: (scope of <time>),(scope of <config>)
OK
Read Command
Responses
AT+CGPSINFOCFG?
+CGPSINFOCFG: <time>,<config>
OK
Write Command
Responses
AT+CGPSINFOCFG=<time
>[,<config>]
OK
(NMEA-0183 Sentence)
……
id
e
nt
ia
Test Command
AT+CGPSINFOCFG=?
OK (if <time>=0)
C
on
f
Defined values
SI
M
C
om
<time>
The range is 0-255, unit is second, after set <time> will report the GPS NMEA sentence every the
seconds.
If <time>=0, module stop reporting the NMEA sentence.
<config>
Range – 0 to 262143
Each bit enables an NMEA sentence output as follows:
Bit 0 – GPGGA (global positioning system fix data)
Bit 1 – GPRMC (recommended minimum specific GPS/TRANSIT data)
Bit 2 – GPGSV (GPS satellites in view)
Bit 3 – GPGSA (GPS DOP and active satellites)
Bit 4 – GPVTG (track made good and ground speed)
Bit 5 – PQXFI (Global Positioning System Extended Fix Data.)
Bit 6 – GLGSV (GLONASS satellites in view GLONASS fixes only)
Bit 7 – GNGSA (1. GPS/2. Glonass/3. GALILE DOP and Active Satellites.)
Bit 8 – GNGNS (fix data for GNSS receivers;output for GPS,GLONASS,GALILEO)
Bit 9 – Reserved
Bit 10 – GAGSV (GALILEO satellites in view)
Bit 11 –Reserved
Bit 12 –Reserved
Bit 13 –Reserved
Bit 14 –Reserved
Bit 15 –Reserved,
SIM7906_SIM7912 Series_AT Command Manual_V1.01
182
2019-11-21
Smart Machine Smart Decision
lF
ile
Bit 16 –BDGSA/PQGSA (BEIDOU/QZSS DOP and active satellites)
Bit 17 –BDGSV/PQGSV (BEIDOUQZSS satellites in view)
Set the desired NMEA sentence bit(s). If multiple NMEA sentence formats are desired, “OR” the
desired bits together.
NOTE: Reserved default 0, set invalid.
For example:
If want to report GPRMC sentence by 10 seconds, should execute AT+CGPSINFOCFG=10,2
ia
Examples
C
on
f
id
e
nt
AT+CGPSINFOCFG=?
+CGPSINFO: (0-255),(0-262143)
OK
AT+CGPSINFOCFG=10,31
OK
$GPGSV,4,1,16,04,53,057,44,02,55,334,44,10,61,023,44,05,45,253,43*7D
$GPGSV,4,2,16,25,10,300,40,17,25,147,40,12,22,271,38,13,28,053,38*77
$GPGSV,4,3,16,26,09,187,35,23,06,036,34,24,,,,27,,,*7A
$GPGSV,4,4,16,09,,,,31,,,,30,,,,29,,,*7D
$GPGGA,051147.0,3113.320991,N,12121.248076,E,1,10,0.8,47.5,M,0,M,,*45
$GPVTG,NaN,T,,M,0.0,N,0.0,K,A*42
$GPRMC,051147.0,A,3113.320991,N,12121.248076,E,0.0,0.0,211211,,,A*66
$GPGSA,A,3,02,04,05,10,12,13,17,23,25,26,,,1.4,0.8,1.2*3B
12.17 AT+CGPSPMD
Configure positioning mode
C
om
Description
This command is used to configure the positioning modes support.
NOTE: Need to restart the module after setting the mode.
SIM PIN
NO
References
Vendor
SI
M
Syntax
Test Command
Responses
AT+CGPSPMD=?
+CGPSPMD: (scope of <mode>)
OK
Read Command
Responses
AT+CGPSPMD?
+CGPSPMD: <mode>
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
183
2019-11-21
Smart Machine Smart Decision
Write Command
Responses
AT+CGPSPMD=<mode>
OK
lF
ile
ERROR
Defined values
C
on
f
id
e
nt
ia
<mode>
Default - 127
Range - 1 to 65407
Each bit enables a supported positioning mode as follows:
Bit 0 – Standalone
Bit 1 – UP MS-based
Bit 2 – UP MS-assisted
Bit 3 – CP MS-based (2G)
Bit 4 – CP MS-assisted (2G)
Bit 5 – CP UE-based (3G)
Bit 6 – CP UE-assisted (3G)
Bit 7 – NOT USED
Bit 8 – UP MS-based (4G)
Bit 9 – UP MS-assisted(4G)
Bit 10 – CP MS-based (4G)
Bit 11 – CP MS-assisted (4G)
Set the desired mode sentence bit(s). If multiple modes are desired, “OR” the desired bits together.
Example, support standalone, UP MS-based and UP MS-assisted, set Binary value 0000 0111, is 7.
Examples
C
om
AT+CGPSPMD=127
OK
12.18 AT+CGPSMSB
Configure based mode switch to standalone
Description
M
This command is used to configure AGPS based mode switching to standalone mode automatically
or not.
SI
SIM PIN
NO
References
Vendor
Syntax
Test Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
184
2019-11-21
Smart Machine Smart Decision
+CGPSMSB: (scope of <mode>)
OK
Read Command
Responses
AT+CGPSMSB?
+CGPSMSB: <mode>
OK
Write Command
Responses
AT+CGPSMSB=<mode>
OK
lF
ile
AT+CGPSMSB=?
ERROR
Examples
C
on
f
AT+CGPSMSB=0
OK
12.19 AT+CGPSHOR
Description
nt
id
e
<mode>
0 – Don’t switch to standalone mode automatically
1 – Switch to standalone mode automatically
ia
Defined values
Configure positioning desired accuracy
The command is used to configure the positioning desired accuracy threshold in meters.
SIM PIN
Vendor
C
om
NO
References
Syntax
Responses
+CGPSHOR: (scope of <acc>), (scope of < acc_f >)
OK
Read Command
AT+CGPSHOR?
Responses
+CGPSHOR: <acc>,<acc_f>
OK
Write Command
AT+CGPSHOR=<acc>[,<ac
c_f>]
Responses
OK
SI
M
Test Command
AT+CGPSHOR=?
ERROR
Defined values
SIM7906_SIM7912 Series_AT Command Manual_V1.01
185
2019-11-21
Smart Machine Smart Decision
lF
ile
<acc>
Range – 0 to 1800000
Default value is 50
<acc_f>
Reserved
Examples
ia
AT+CGPSHOR=50
OK
nt
12.20 AT+CGPSNOTIFY LCS respond positioning request
Description
SIM PIN
NO
id
e
This command is used to respond to the incoming request for positioning request message.
References
Vendor
Test Command
C
on
f
Syntax
Responses
AT+CGPSNOTIFY=?
+CGPSNOTIFY: (list of supported <resp>s)
OK
Write Command
AT+CGPSNOTIFY=<resp>
Responses
OK
C
om
ERROR
Defined values
LCS notify verify accept
LCS notify verify deny
LCS notify verify no response
M
<resp>
0 –
1 –
2 –
SI
Examples
AT+CGPSNOTIFY=?
+CGPSNOTIFY: (0-2)
OK
AT+CGPSNOTIFY=0
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
186
2019-11-21
Smart Machine Smart Decision
12.21 AT+CGNSSINFO
Get GNSS fixed position information
lF
ile
Description
This command is used to get current position related information.
SIM PIN
NO
References
Vendor
Syntax
Responses
+CGNSSINFO: (scope of <time>)
OK
Read Command
Responses
AT+CGNSSINFO?
+CGNSSINFO: <time>
OK
Write Command
AT+CGNSSINFO=<time>
Responses
OK
+CGNSSINFO:
[<mode>],[<GPS-SVs>],[<GLONASS-SVs>],[BEIDOU-SVs],
[<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC-time>],[<alt>],
[<speed>],[<course>],[<PDOP>],[HDOP],[VDOP]
C
on
f
id
e
nt
ia
Test Command
AT+CGNSSINFO=?
OK (if <time>=0)
C
om
Execution Command
AT+CGNSSINFO
Responses
+CGNSSINFO:
[<mode>],[<GPS-SVs>],[<GLONASS-SVs>],[BEIDOU-SVs],
[<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC-time>],[<alt>],
[<speed>],[<course>],[<PDOP>],[HDOP],[VDOP]
OK
Defined values
SI
M
<mode>
Fix mode 2=2D fix 3=3D fix
<GPS-SVs>
GPS satellite valid numbers
< GLONASS-SVs >
GLONASS satellite valid numbers
<BEIDU-SVs>
BEIDOU satellite valid numbers
<lat>
scope: 00-12
scope: 00-12
scope: 00-12
SIM7906_SIM7912 Series_AT Command Manual_V1.01
187
2019-11-21
Smart Machine Smart Decision
C
on
f
id
e
nt
ia
lF
ile
Latitude of current position. Output format is ddmm.mmmmmm
<N/S>
N/S Indicator, N=north or S=south
<log>
Longitude of current position. Output format is dddmm.mmmmmm
<E/W>
E/W Indicator, E=east or W=west
<date>
Date. Output format is ddmmyy
<UTC time>
UTC Time. Output format is hhmmss.s
<alt>
MSL Altitude. Unit is meters.
<speed>
Speed Over Ground. Unit is knots.
<course>
Course. Degrees.
<time>
The range is 0-255, unit is second, after set <time> will report the GPS information every the
seconds.
<PDOP>
Position Dilution Of Precision.
<HDOP>
Horizontal Dilution Of Precision.
<VDOP>
Vertical Dilution Of Precision.
C
om
Examples
SI
M
AT+CGNSSINFO=?
+CGNSSINFO: (0-255)
OK
AT+CGNSSINFO?
+CGPSINFO: 0
OK
AT+CGNSSINFO
+CGNSSINFO:
2,09,05,00,3113.330650,N,12121.262554,E,131117,091918.0,32.9,0.0,255.0,1.1,0.8,0.7
OK
AT+CGNSSINFO (if not fix,will report null)
+CGNSSINFO: ,,,,,,,,,,,,,,,
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
188
2019-11-21
Smart Machine Smart Decision
12.22
AT+CGNSSMODE Configure GNSS support mode
lF
ile
Description
This command is used to configure GPS, GLONASS, BEIDOU and QZSS support mode.
And DPO(Dynamic power optimization) status
Module should reboot to take effective.
NO
References
Vendor
ia
SIM PIN
Syntax
Responses
+CGNSSMODE: (scope of <gnss_mode>),(scope of <dpo_mode>)
OK
Read Command
AT+CGNSSMODE?
Responses
+CGNSSMODE: <gnss_mode>,<dpo_mode>
OK
Write Command
AT+CGNSSMODE=<mode
>[,<dpo_mode>]
Responses
OK
id
e
C
on
f
Defined values
nt
Test Command
AT+CGNSSMODE=?
ERROR
M
C
om
<gnss_mode>
Range – 0 to 15
Bit0: GLONASS
Bit1: BEIDOU
Bit2: GALILEO
Bit3: QZSS
1: enable 0:disable
GPS always support
<dpo_mode>
1: enable DPO
0: disable DPO
SI
Examples
AT+CGNSSMODE=15,1
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
189
2019-11-21
Smart Machine Smart Decision
Description
Assistant file download successfully
Assistant file doesn’t exist
Assistant file check error
220
221
222
Unknown error for HTTP
HTTP task is busy
Failed to resolve server address
223
224
225
226
227
HTTP timeout
Failed to transfer data
Memory error
Invalid parameter
Network error
nt
id
e
220~227 codes are same as Unsolicited HTTP codes
ia
Code of <err>
0
1
2
lF
ile
12.23 Unsolicited XTRA download Codes
AT+CLBS Base station location
C
on
f
12.24
Description
The write command is used to base station location.
NOTE:
1. The LBS is only support in WCDMA/LTE net mode.
2. It needs to execute AT+CNETSTART to open network before execute the AT+CLBS write
command. It needs to execute AT+CNETSTOP to close network after complete the LBS operation.
SIM PIN
3GPP TS 27.007
C
om
YES
References
Syntax
Responses
AT+CLBS=?
+CLBS:
(1,2,3,4,9),(1-24),(-180.000000-180.000000),(-90.000000-90.00000
0),(0,1)
SI
M
Test Command
OK
Write Command
Responses
AT+CLBS=<type>[,<cid>[,
[<longitude>,<latitude>],[<l
on_type>]]]
OK
1)type = 1,get longitude and latitude
SIM7906_SIM7912 Series_AT Command Manual_V1.01
190
2019-11-21
Smart Machine Smart Decision
+CLBS: <ret_code>[,<longitude>,<latitude>,<acc>]
lF
ile
2)type = 2,get detail address
+CLBS: <ret_code>[,<detail_addr>]
3)type = 3,get access times
+CLBS: <ret_code>[,<times>]
ERROR
Defined values
C
on
f
ERROR
id
e
+CLBS: <ret_code>
nt
5)type = 9, report positioning error
+CLBS: <ret_code>
ia
4)type = 4,get longitude latitude and date time
+CLBS:
<ret_code>[,<longitude>,<latitude>,<acc>,<date>,<time>]
SI
M
C
om
<type>
A numeric parameter which specifies the location type.
1 use 3 cell’s information
2 get detail address
3 get access times
4 get longitude latitude and date time
9 report positioning error
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command).
1…24
NOTE:This parameter takes no effect in SIM7906/SIM7912, it’s only in order to keep compatible
with the previous software version and other projects, support convenience for the customers.
<longitude>
Current longitude in degrees.
<latitude>
Current latitude in degrees.
<detail_addr>
Current detail address. It based the UCS2 coding. Each 4 characters in the URC is for one
UCS2 character.
<acc>
Positioning accuracy.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
191
2019-11-21
ia
nt
C
on
f
id
e
<lon_type>
The type of longitude and latitude
0 WGS84,the default type
1 GCJ02.
<times>
access service times.
<data>
service date(UTC, the format is YYYY/MM/DD).
<time>
service time(UTC, the format is HH:MM:SS).
<ret_code>
The result code.
0
Success
1 Parameter error returned by server.
2 Service out of time returned by server.
3 Location failed returned by server.
4 Query timeout returned by server.
5 Certification failed returned by server.
6 Server LBS error success.
7 Server LBS error failed.
80 Report LBS to server success
81 Report LBS to server parameter error
82 Report LBS to server failed
110 Other Error
lF
ile
Smart Machine Smart Decision
LBS is busy.
Open network error.
Close network error.
Operation timeout.
DNS error.
Create socket error.
Connect socket error.
Close socket error.
Get cell info error.
Get IMEI error.
Send data error.
Receive data error.
NONET error.
Net not opened.
SI
M
C
om
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Examples
AT+CLBS=?
SIM7906_SIM7912 Series_AT Command Manual_V1.01
192
2019-11-21
Smart Machine Smart Decision
+CLBS: (1,2,3,4,9),( 1-24),(-180.000000-180.000000),(-90.000000-90.000000),(0,1)
lF
ile
OK
AT+CLBS=1 (need execute AT+CNETSTART before this command)
OK
+CLBS: 0,31.228525,121.380295,500
AT+CLBS=2 (need execute AT+CNETSTART before this command)
OK
nt
ia
+CLBS:
0,
4e0a6d775e020020957f5b81533a002091d1949f8def002097608fd166688baf79d162805927697c
AT+CLBS=3 (need execute AT+CNETSTART before this command)
OK
id
e
+CLBS: 0,22
AT+CLBS=4 (need execute AT+CNETSTART before this command)
OK
C
on
f
+CLBS: 0,31.228525,121.380295,500,2025/06/07,10:49:08
AT+CLBS=9 (need execute AT+CNETSTART before this command)
OK
+CLBS: 80
12.25 AT+CLBSCFG Base station location configure
C
om
Description
The write command is used to set and query the base station location configure.
SIM PIN
YES
References
3GPP TS 27.007
SI
M
Syntax
Test Command
Responses
AT+CLBSCFG=?
+CLBSCFG: (0-1), 3,”Param Value”
OK
Write Command
Responses
AT+CLBSCFG=<operate>,<
para>[,<value>]
+CLBSCFG: 0,<para>,<value>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
193
2019-11-21
Smart Machine Smart Decision
OK
OK
lF
ile
ERROR
+CLBSCFG: <ret_code>
ERROR
Examples
nt
C
on
f
id
e
<operate>
A numeric parameter which specifies the operator.
0 read operator
1 write operator
<para>
A numeric parameter which specifies the operator parameter.
3 Server’s address
lbs-simcom.com:3002
<value>
The value of parameter.
The allowed <value> is "lbs-simcom.com:3002".
Server’s address of "lbs-simcom.com:3002" is free.
<ret_code>
Please refer to the <ret_code> of AT+CLBS.
ia
Defined values
C
om
AT+CLBSCFG=?
+CLBSCFG: (0-1),3,"Param Value"
OK
AT+CLBSCFG=0,3
+CLBSCFG: 0,3,"lbs-simcom.com:3002"
M
OK
AT+CLBSCFG=1,3,”lbs-simcom.com:3002”
OK
SI
12.26 AT+CGTP Get the IZAT location
Description
The write command is used to get IZAT location, you can get the IZAT location,data,time,accuary
SIM PIN
References
SIM7906_SIM7912 Series_AT Command Manual_V1.01
194
2019-11-21
Smart Machine Smart Decision
YES
3GPP TS 27.007
Response
Test Command
AT+CGTP=?
OK
Response
+CGTP:
<feature_control>,<user_session_control>,<
primary_svr_address>,<primary_svr_port>,<secondary_svr
_address>,< secondary_svr_port>
ia
Read Command
AT+CGTP?
nt
C
on
f
Execute Command
/*Start IZAT location */
AT+CGTP
OK
Response
a)If successfully:
OK
b)If failed:
ERROR
Response
OK
+CTPCELL:
<latitude>,<longitude>,<date>,<time>,<accuary>
id
e
Write Command
/*Set IZAT NV param*/
AT+CGTP=<mode>
Defined Values
< feature_control >
lF
ile
Syntax
0: GTP disabled
C
om
1: GTP enabled
< user_session_control >
M
< primary_svr_address >
SI
< primary_svr_port >
< secondary_svr_address >
If you want to use IZAT function,this value must be 1
0 – Connection to the XTS is never permitted
1 – Connection to the XTS is always permitted
If you want to use IZAT function,this value must be 1
the IP address of the primary GTP Server.
If you want to use IZAT function,this value must be
gtp1.izatcloud.net
the port number of the primary
If you want to use IZAT function,this value must be 443
the IP address of the secondary GTP Server.
If you want to use IZAT function,this value must be
gtp2.izatcloud.net
SIM7906_SIM7912 Series_AT Command Manual_V1.01
195
2019-11-21
Smart Machine Smart Decision
< secondary_svr_port >
the port number of the primary
lF
ile
If you want to use IZAT function,this value must be 443
Latitude (specified in WGS84 datum).
Type: Floating point
Units: Degrees
Range: -90.0 to 90.0
Positive values indicate northern latitude
Negative values indicate southern latitude
Longitude (specified in WGS84 datum).
Type: Floating point
Units: Degrees
Range: -180.0 to 180.0
Positive values indicate eastern longitude
Negative values indicate western longitude
Output format is yyyy-mm-dd
< latitude >
nt
ia
< longitude >
id
e
< date >
UTC time output format is hh:mm:ss
< time >
<mode>
Examples
Horizontal position uncertainty (circular).
Type: Floating point
Units: Meters
C
on
f
< accuary >
1:Set NV value
C
om
Before all IZAT related operations, we should ensure the following:
a) ensure network is registered
AT+CSQ
+CSQ: 23,0
OK
M
AT+CREG?
+CREG: 0,1
SI
OK
Test IZAT function
SIM7906_SIM7912 Series_AT Command Manual_V1.01
196
2019-11-21
Smart Machine Smart Decision
//Query IZAT NV set
lF
ile
AT+CGTP?
+CGTP: 1,1,gtp1.izatcloud.net,443,gtp2.izatcloud.net,443
OK
//If query result is not this , need set it, then must restart module
AT+CGTP=1
OK
nt
ia
// Start IZAT location
AT+CGTP
OK
SI
M
C
om
C
on
f
id
e
+GTPCELL: 35.523384,104.507509,2018-12-10 09:12:48,1633580.000000
SIM7906_SIM7912 Series_AT Command Manual_V1.01
197
2019-11-21
Smart Machine Smart Decision
13.1
AT+CVHU
lF
ile
13 AT Commands for Call Control
Voice hang up control
Description
NO
References
3GPP TS 27.007
nt
SIM PIN
ia
Write command selects whether ATH or “drop DTR” shall cause a voice connection to be
disconnected or not. By voice connection is also meant alternating mode calls that are currently in
voice mode.
id
e
Syntax
Responses
+CVHU: (list of supported <mode>s)
OK
Read Command
AT+CVHU?
Responses
+CVHU: <mode>
OK
C
on
f
Test Command
AT+CVHU=?
Write Command
AT+CVHU=<mode>
Responses
OK
ERROR
C
om
Execution Command
AT+CVHU
Responses
Set default value:
OK
Defined values
M
<mode>
0 – “Drop DTR” ignored but OK response given. ATH disconnects.
1 – “Drop DTR” and ATH ignored but OK response given.
SI
Examples
AT+CVHU=0
OK
AT+CVHU?
+CVHU: 0
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
198
2019-11-21
Smart Machine Smart Decision
13.2
AT+CHUP Hang up call
lF
ile
Description
This command is used to cancel voice calls. If there is no call, it will do nothing but OK response is
given. After running AT+CHUP, multiple “VOICE CALL END: ” may be reported which relies on
how many calls exist before calling this command.
NO
References
3GPP TS 27.007
ia
SIM PIN
Syntax
Responses
OK
Execution Command
AT+CHUP
Responses
VOICE CALL: END: <time>
[…
VOICE CALL: END: <time>]
OK
Defined values
id
e
C
on
f
No call:
OK
nt
Test Command
AT+CHUP=?
C
om
<time>
Voice call connection time.
Format – HHMMSS (HH: hour, MM: minute, SS: second)
Examples
AT+CHUP
VOICE CALL:END: 000017
OK
AT+CBST Select bearer service type
M
13.3
SI
Description
Write command selects the bearer service <name> with data rate <speed>, and the connection
element <ce> to be used when data calls are originated. Values may also be used during mobile
terminated data call setup, especially in case of single numbering scheme calls.
SIM PIN
References
SIM7906_SIM7912 Series_AT Command Manual_V1.01
199
2019-11-21
Smart Machine Smart Decision
YES
3GPP TS 27.007
lF
ile
Syntax
Execution Command
AT+CBST
ia
Write Command
AT+CBST=
<speed>[,<name>[,<ce>]]
ERROR
Responses
Set default value:
OK
<speed>
0
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
autobauding(automatic selection of the speed; this setting is possible in case of 3.1
kHz modem and non-transparent service)
9600 bps (V.32)
9600 bps (V.34)
14400 bps(V.34)
28800 bps(V.34)
33600 bps(V.34)
9600 bps(V.120)
14400 bps(V.120)
28800 bps(V.120)
56000 bps(V.120)
9600 bps(V.110)
14400 bps(V.110)
28800 bps(V.110 or X.31 flag stuffing)
38400 bps(V.110 or X.31 flag stuffing)
56000 bps(V.110 or X.31 flag stuffing)
64000 bps(X.31 flag stuffing)
64000 bps(bit transparent)
64000 bps(multimedia)
SI
M
C
om
7
12
14
16
17
39
43
48
51
71
75
80
81
83
84
116
134
<name>
0 –
1 –
–
C
on
f
Defined values
nt
Read Command
AT+CBST?
Responses
+CBST: (list of supported <speed>s), (list of supported <name>s),
(list of supported <ce>s)
OK
Responses
+CBST: <speed>,<name>,<ce>
OK
Responses
OK
id
e
Test Command
AT+CBST=?
Asynchronous modem
Synchronous modem
SIM7906_SIM7912 Series_AT Command Manual_V1.01
200
2019-11-21
Smart Machine Smart Decision
lF
ile
4 – data circuit asynchronous (RDI)
<ce>
0 – transparent
1 – non-transparent
NOTE: If <speed> is set to 116 or 134, it is necessary that <name> is equal to 1 and <ce> is equal
to 0.
Examples
nt
AT+CRLP Radio link protocol
id
e
13.4
ia
AT+CBST=0,0,1
OK
AT+CBST?
+CBST:0,0,1
OK
Description
SIM PIN
References
3GPP TS 27.007
C
om
YES
C
on
f
Radio Link Protocol(RLP) parameters used when non-transparent data calls are originated may be
altered with write command.
Read command returns current settings for each supported RLP version <verX>. Only RLP
parameters applicable to the corresponding <verX> are returned.
Test command returns values supported by the TA as a compound value. If ME/TA supports several
RLP versions <verX>, the RLP parameter value ranges for each <verX> are returned in a separate
line.
Syntax
SI
M
Test Command
AT+CRLP=?
Read Command
AT+CRLP?
Responses
+CRLP: (list of supported <iws>s), (list of supported <mws>s),
(list of supported <T1>s), (list of supported <N2>s) [,<ver1>
[,(list of supported <T4>s)]][<CR><LF>
+CRLP: (list of supported <iws>s), (list of supported <mws>s),
(list of supported <T1>s), (list of supported <N2>s) [,<ver2>
[,(list of supported <T4>s)]]
[...]]
OK
Responses
+CRLP: <iws>, <mws>, <T1>, <N2> [,<ver1> [, <T4>]][<CR>
<LF>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
201
2019-11-21
Smart Machine Smart Decision
Write Command
AT+CRLP=<iws>
[,<mws>[,<T1>[,<N2>
[,<ver>[,<T4>]]]]]
Responses
OK
Execution Command
AT+CRLP
Responses
OK
lF
ile
+CRLP:<iws>,<mws>,<T1>,<N2>[,<ver2>[,<T4>]]
[...]]
OK
ia
ERROR
Defined values
C
on
f
id
e
nt
<ver>, <verX>
RLP version number in integer format, and it can be 0, 1 or 2; when version indication is not
present it shall equal 1.
<iws>
IWF to MS window size.
<mws>
MS to IWF window size.
<T1>
Acknowledgement timer.
<N2>
Retransmission attempts.
<T4>
Re-sequencing period in integer format.
NOTE: <T1> and <T4> are in units of 10 ms.
C
om
Examples
M
AT+CRLP?
+CRLP:61,61,48,6,0
+CRLP:61,61,48,6,1
+CRLP:240,240,52,6,2
OK
AT+CR Service reporting control
SI
13.5
Description
SIM7906_SIM7912 Series_AT Command Manual_V1.01
202
2019-11-21
Smart Machine Smart Decision
SIM PIN
YES
lF
ile
Write command controls whether or not intermediate result code “+CR: <serv>” is returned from
the TA to the TE. If enabled, the intermediate result code is transmitted at the point during connect
negotiation at which the TA has determined which speed and quality of service will be used, before
any error control or data compression reports are transmitted, and before the intermediate result
code CONNECT is transmitted.
References
3GPP TS 27.007
Responses
+CR: (list of supported <mode>s)
OK
Read Command
AT+CR?
Responses
+CR: <mode>
OK
Write Command
AT+CR=<mode>
Responses
OK
Execution Command
AT+CR
Responses
Set default value:
OK
id
e
C
on
f
Defined values
nt
Test Command
AT+CR=?
ia
Syntax
M
C
om
<mode>
0 – disables reporting
1 – enables reporting
<serv>
ASYNC
asynchronous transparent
SYNC
synchronous transparent
REL ASYNC
asynchronous non-transparent
REL sync
synchronous non-transparent
GPRS [<L2P>]
GPRS
The optional <L2P> proposes a layer 2 protocol to use between the MT and the TE.
SI
Examples
AT+CR?
+CR:0
OK
AT+CR=1
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
203
2019-11-21
Smart Machine Smart Decision
13.6
AT+CRC
Cellular result codes
lF
ile
Description
Write command controls whether or not the extended format of incoming call indication or GPRS
network request for PDP context activation is used. When enabled, an incoming call is indicated to
the TE with unsolicited result code “+CRING: <type>” instead of the normal RING.
Test command returns values supported by the TA as a compound value.
YES
References
3GPP TS 27.007
ia
SIM PIN
nt
Syntax
Responses
+CRC: (list of supported <mode>s)
OK
Read Command
AT+CRC?
Responses
+CRC: <mode>
OK
C
on
f
id
e
Test Command
AT+CRC=?
Write Command
AT+CRC=<mode>
Responses
OK
Execution Command
AT+CRC
Responses
Set default value:
OK
C
om
Defined values
SI
M
<mode>
0 – disable extended format
1 – enable extended format
<type>
ASYNC
asynchronous transparent
SYNC
synchronous transparent
REL ASYNC
asynchronous non-transparent
REL SYNC
synchronous non-transparent
FAX
facsimile
VOICE
normal voice
VOICE/XXX
voice followed by data(XXX is ASYNC, SYNC, REL ASYNC or REL
SYNC)
ALT VOICE/XXX alternating voice/data, voice first
ALT XXX/VOICE alternating voice/data, data first
ALT FAX/VOICE alternating voice/fax, fax first
SIM7906_SIM7912 Series_AT Command Manual_V1.01
204
2019-11-21
Smart Machine Smart Decision
GPRS
GPRS network request for PDP context activation
Examples
ia
AT+CLCC List current calls
nt
13.7
lF
ile
AT+CRC=1
OK
AT+CRC?
+CRC: 1
OK
Description
NO
References
3GPP TS 27.007
Syntax
Test Command
AT+CLCC=?
C
om
Read Command
AT+CLCC?
C
on
f
SIM PIN
id
e
This command isused to return list of current calls of ME. If command succeeds but no calls are
available, no information response is sent to TE.
Write Command
AT+CLCC=<n>
SI
M
Execution Command
AT+CLCC
Responses
+CLCC: (list of supported <n>s)
OK
Responses
+CLCC: <n>
OK
Responses
OK
Responses
+CLCC:<id1>,<dir>,<stat>,<mode>,<mpty>[,<number>,<type>[,<
alpha>]][<CR><LF>
+CLCC:<id2>,<dir>,<stat>,<mode>,<mpty>[,<number>,<type>[,<
alpha>]]
[...]]
OK
ERROR
+CME ERROR: <err>
Defined values
SIM7906_SIM7912 Series_AT Command Manual_V1.01
205
2019-11-21
Smart Machine Smart Decision
<n>
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
0 – Don’t report a list of current calls of ME automatically when the current call status
changes.
1 – Report a list of current calls of ME automatically when the current call status changes.
<idX>
Integer type, call identification number, this number can be used in +CHLD command operations.
<dir>
0 – mobile originated (MO) call
1 – mobile terminated (MT) call
<stat>
State of the call:
0 – active
1 – held
2 – dialing (MO call)
3 – alerting (MO call)
4 – incoming (MT call)
5 – waiting (MT call)
6 – disconnect
<mode>
bearer/teleservice:
0 – voice
1 – data
2 – fax
9 – unknown
<mpty>
0 – call is not one of multiparty (conference) call parties
1 – call is one of multiparty (conference) call parties
<number>
String type phone number in format specified by <type>.
<type>
Type of address octet in integer format;
128 – Restricted number type includes unknown type and format
145 – International number type
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
129 – Otherwise
<alpha>
String type alphanumeric representation of <number> corresponding to the entry found in
phonebook; used character set should be the one selected with command Select TE Character Set
AT+CSCS.
Examples
SIM7906_SIM7912 Series_AT Command Manual_V1.01
206
2019-11-21
Smart Machine Smart Decision
id
e
Description
ia
AT+CEER Extended error report
nt
13.8
lF
ile
ATD10011;
OK
AT+CLCC
+CLCC: 1,0,0,0,0,"10011",129,"sm"
OK
RING (with incoming call)
AT+CLCC
+CLCC: 1,1,4,0,0,"02152063113",128,"gongsi"
OK
SIM PIN
YES
C
on
f
Execution command causes the TA to return the information text <report>, which should offer the
user of the TA an extended report of the reason for:
1 The failure in the last unsuccessful call setup(originating or answering) or in-call
modification.
2 The last call release.
3 The last unsuccessful GPRS attach or unsuccessful PDP context activation.
4 The last GPRS detach or PDP context deactivation.
References
3GPP TS 27.007
C
om
Syntax
Responses
OK
Execution Command
AT+CEER
Responses
+CEER:<report>
OK
M
Test Command
AT+CEER=?
SI
Defined values
<report>
Wrong information which is possibly occurred.
Examples
AT+CEER
+CEER: Invalid/incomplete number
SIM7906_SIM7912 Series_AT Command Manual_V1.01
207
2019-11-21
Smart Machine Smart Decision
OK
AT+CCWA Call waiting
lF
ile
13.9
Description
nt
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+CCWA=?
Responses
+CCWA: (list of supported <n>s)
C
on
f
OK
Read Command
AT+CCWA?
id
e
SIM PIN
ia
This command allows control of the Call Waiting supplementary service. Activation, deactivation
and status query are supported. When querying the status of a network service (<mode>=2) the
response line for 'not active' case (<status>=0) should be returned only if service is not active for
any <class>. Parameter <n> is used to disable/enable the presentation of an unsolicited result code
+CCWA: <number>,<type>,<class> to the TE when call waiting service is enabled. Command
should be abortable when network is interrogated.
Responses
+CCWA: <n>
OK
C
om
Write Command
AT+CCWA=
<n>[,<mode>[,<class>]]
+CCWA:<status>,<class>[<CR><LF>
+CCWA: <status>, <class>[...]]
OK
ERROR
+CME ERROR: <err>
Responses
Set default value (<n>=0):
OK
M
Execution Command
AT+CCWA
Responses
When <mode>=2 and command successful:
SI
Defined values
<n>
Sets/shows the result code presentation status in the TA
0 – disable
1 – enable
<mode>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
208
2019-11-21
C
on
f
id
e
nt
ia
When <mode> parameter is not given, network is not interrogated:
0 – disable
1 – enable
2 – query status
<class>
It is a sum of integers each representing a class of information (default 7)
1
– voice (telephony)
2
– data (refers to all bearer services)
4
– fax (facsimile services)
7
– voice,data and fax(1+2+4)
8
– short message service
16
– data circuit sync
32
– data circuit async
64
– dedicated packet access
128 – dedicated PAD access
255 – The value 255 covers all classes
<status>
0 – not active
1 – active
<number>
String type phone number of calling address in format specified by <type>.
<type>
Type of address octet in integer format;
128 – Restricted number type includes unknown type and format
145 – International number type
129 – Otherwise
lF
ile
Smart Machine Smart Decision
C
om
Examples
M
AT+CCWA=?
+CCWA:(0-1)
OK
AT+CCWA?
+CCWA: 0
OK
SI
13.10 AT+CHLD Call related supplementary services
Description
SIM7906_SIM7912 Series_AT Command Manual_V1.01
209
2019-11-21
Smart Machine Smart Decision
SIM PIN
References
3GPP TS 27.007
ia
YES
lF
ile
This command allows the control the following call related services:
1. A call can be temporarily disconnected from the ME but the connection is retained by the
network.
2. Multiparty conversation (conference calls).
3. The served subscriber who has two calls (one held and the other either active or alerting)
can connect the other parties and release the served subscriber's own connection.
Calls can be put on hold, recovered, released, added to conversation, and transferred. This is
based on the GSM/UMTS supplementary services.
Responses
+CHLD: (list of supported <n>s)
OK
Write Command
AT+CHLD=<n>
Responses
OK
ERROR
id
e
Test Command
AT+CHLD=?
nt
Syntax
C
on
f
+CME ERROR: <err>
Execution Command
AT+CHLD
Default to <n>=2.
Responses
OK
ERROR
+CME ERROR: <err>
C
om
Defined values
SI
M
<n>
0
– Terminate all held calls; or set User Determined User Busy for a waiting call
1
– Terminate all active calls and accept the other call (waiting call or held call)
1X – Terminate a specific call X
2
– Place all active calls on hold and accept the other call (waiting call or held call) as
the active call
2X – Place all active calls except call X on hold
3
– Add the held call to the active calls
4
– Connect two calls and cut off the connection between users and them simultaneously
Examples
AT+CHLD=?
+CHLD: (0,1,1x,2,2x,3,4)
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
210
2019-11-21
Smart Machine Smart Decision
13.11 AT+CCFC Call forwarding number and conditions
lF
ile
Description
This command allows control of the call forwarding supplementary service. Registration, erasure,
activation, deactivation, and status query are supported.
YES
References
3GPP TS 27.007
Syntax
Responses
+CCFC: (list of supported <reason>s)
nt
Test Command
AT+CCFC=?
OK
id
e
Responses
When <mode>=2 and command successful:
+CCFC: <status>,<class1>[,<number>,<type>
[,<subaddr>,<satype>[,<time>]]][<CR><LF>
+CCFC: <status>,<class2>[,<number>,<type>
C
on
f
Write Command
AT+CCFC=<reason>,<mode
>[,<number>[,<type>[,<clas
s>[,<subaddr>[,<satype>[,<ti
me> ]]]]]]
ia
SIM PIN
[,<subaddr>,<satype>[,<time>]]][...]]
OK
ERROR
+CME ERROR:<err>
Defined values
SI
M
C
om
<reason>
0 – unconditional
1 – mobile busy
2 – no reply
3 – not reachable
4 – all call forwarding
5 – all conditional call forwarding
<mode>
0 – disable
1 – enable
2 – query status
3 – registration
4 – erasure
<number>
String type phone number of forwarding address in format specified by <type>.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
211
2019-11-21
Smart Machine Smart Decision
Examples
C
on
f
id
e
nt
ia
lF
ile
<type>
Type of address octet in integer format:
145 – dialing string <number> includes international access code character ‘+’
129 – otherwise
<subaddr>
String type sub address of format specified by <satype>.
<satype>
Type of sub address octet in integer format, default 128.
<classX>
It is a sum of integers each representing a class of information (default 7):
1
– voice (telephony)
2
– data (refers to all bearer services)
4
– fax (facsimile services)
16
– data circuit sync
32 – data circuit async
64
– dedicated packet access
128 – dedicated PAD access
255 – The value 255 covers all classes
<time>
1...30 – when "no reply" is enabled or queried, this gives the time in seconds to wait before call
is forwarded, default value 20.
<status>
0 – not active
1 – active
C
om
AT+CCFC=?
+CCFC: (0,1,2,3,4,5)
OK
AT+CCFC=0,2
+CCFC: 0,255
OK
M
13.12 AT+CLIP Calling line identification presentation
SI
Description
SIM7906_SIM7912 Series_AT Command Manual_V1.01
212
2019-11-21
Smart Machine Smart Decision
YES
References
ia
SIM PIN
lF
ile
This command refers to the GSM/UMTS supplementary service CLIP (Calling Line Identification
Presentation) that enables a called subscriber to get the calling line identity (CLI) of the calling
party when receiving a mobile terminated call.
Write command enables or disables the presentation of the CLI at the TE. It has no effect on the
execution of the supplementary service CLIP in the network.
When the presentation of the CLI at the TE is enabled (and calling subscriber allows), +CLIP:
<number>,<type>,,[,[<alpha>][,<CLI validity>]] response is returned after every RING (or
+CRING: <type>; refer sub clause "Cellular result codes +CRC") result code sent from TA to TE. It
is manufacturer specific if this response is used when normal voice call is answered.
3GPP TS 27.007
nt
Syntax
Responses
+CLIP: (list of supported <n>s)
OK
Read Command
AT+CLIP?
id
e
Test Command
AT+CLIP=?
Responses
+CLIP: <n>,<m>
C
on
f
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CLIP=<n>
Responses
OK
ERROR
C
om
+CME ERROR: <err>
Execution Command
AT+CLIP
Responses
Set default value(<n>=0):
OK
Defined values
SI
M
<n>
Parameter sets/shows the result code presentation status in the TA:
0 – disable
1 – enable
<m>
0 – CLIP not provisioned
1 – CLIP provisioned
2 – unknown (e.g. no network, etc.)
<number>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
213
2019-11-21
Smart Machine Smart Decision
Examples
C
on
f
AT+CLIP=1
OK
RING (with incoming call)
+CLIP: "02152063113",128,,,"gongsi",0
id
e
nt
ia
lF
ile
String type phone number of calling address in format specified by <type>.
<type>
Type of address octet in integer format;
128 – Restricted number type includes unknown type and format
145 – International number type
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
129 – Otherwise
<alpha>
String type alphanumeric representation of <number> corresponding to the entry found in phone
book.
<CLI validity>
0 – CLI valid
1 – CLI has been withheld by the originator
2 – CLI is not available due to interworking problems or limitations of originating
network
13.13 AT+CLIR Calling line identification restriction
Description
M
C
om
This command refers to CLIR-service that allows a calling subscriber to enable or disable the
presentation of the CLI to the called party when originating a call.
Write command overrides the CLIR subscription (default is restricted or allowed) when temporary
mode is provisioned as a default adjustment for all following outgoing calls. This adjustment can be
revoked by using the opposite command.. If this command is used by a subscriber without
provision of CLIR in permanent mode the network will act.
Read command gives the default adjustment for all outgoing calls (given in <n>), and also triggers
an interrogation of the provision status of the CLIR service (given in <m>).
Test command returns values supported as a compound value.
SI
SIM PIN
YES
References
3GPP TS 27.007
Syntax
Test Command
Responses
SIM7906_SIM7912 Series_AT Command Manual_V1.01
214
2019-11-21
Smart Machine Smart Decision
AT+CLIR=?
+CLIR: (list of supported <n>s)
OK
Responses
+CLIR: <n>,<m>
lF
ile
Read Command
AT+CLIR?
OK
ERROR
+CME ERROR: <err>
Responses
OK
ia
Write Command
AT+CLIR=<n>
ERROR
nt
+CME ERROR: <err>
Defined values
id
e
<n>
0
1
2
– presentation indicator is used according to the subscription of the CLIR service
– CLIR invocation
– CLIR suppression
0
1
2
3
4
–
–
–
–
–
C
on
f
<m>
CLIR not provisioned
CLIR provisioned in permanent mode
unknown (e.g. no network, etc.)
CLIR temporary mode presentation restricted
CLIR temporary mode presentation allowed
C
om
Examples
AT+CLIR=?
+CLIR:(0-2)
OK
13.14 AT+COLP Connected line identification presentation
SI
M
Description
This command refers to the GSM/UMTS supplementary service COLP(Connected Line
Identification Presentation) that enables a calling subscriber to get the connected line identity
(COL) of the called party after setting up a mobile originated call. The command enables or
disables the presentation of the COL at the TE. It has no effect on the execution of the
supplementary service COLR in the network.
When enabled (and called subscriber allows), +COLP:<number>, <type> [,<subaddr>, <satype>
[,<alpha>]] intermediate result code is returned from TA to TE before any +CR responses. It is
SIM7906_SIM7912 Series_AT Command Manual_V1.01
215
2019-11-21
Smart Machine Smart Decision
manufacturer specific if this response is used when normal voice call is established.
When the AT+COLP=1 is set, any data input immediately after the launching of “ATDXXX;” will
stop the execution of the ATD command, which may cancel the establishing of the call.
YES
References
lF
ile
SIM PIN
3GPP TS 27.007
Syntax
Test Command
AT+COLP=?
Responses
+COLP: (list of supported <n>s)
Responses
+COLP: <n>,<m>
OK
id
e
ERROR
nt
Read Command
AT+COLP?
ia
OK
+CME ERROR: <err>
Write Command
AT+COLP =<n>
Responses
OK
C
on
f
ERROR
+CME ERROR: <err>
Execution Command
AT+COLP
Defined values
Responses
Set default value(<n>=0, <m>=0):
OK
M
C
om
<n>
Parameter sets/shows the result code presentation status in the TA:
0 – disable
1 – enable
<m>
0 – COLP not provisioned
1 – COLP provisioned
2 – unknown (e.g. no network, etc.)
SI
Examples
AT+COLP?
+COLP: 1,0
OK
ATD10086;
VOICE CALL: BEGIN
SIM7906_SIM7912 Series_AT Command Manual_V1.01
216
2019-11-21
Smart Machine Smart Decision
+COLP: "10086",129,,,
13.15 AT+VTS
lF
ile
OK
DTMF and tone generation
Description
NO
References
3GPP TS 27.007
Syntax
AT+VTS=?
Write Command
AT+VTS=<dtmf>
[,<duration>]
Responses
C
on
f
Test Command
id
e
SIM PIN
nt
ia
This command allows the transmission of DTMF tones and arbitrary tones which cause the Mobile
Switching Center (MSC) to transmit tones to a remote subscriber. The command can only be used
in voice mode of operation (active voice call).
NOTE: The END event of voice call will terminate the transmission of tones, and as an operator
option, the tone may be ceased after a pre-determined time whether or not tone duration has been
reached.
Responses
OK
ERROR
C
om
AT+VTS=<dtmf-string>
+VTS: (list of supported<dtmf>s)
OK
Defined values
SI
M
<dtmf>
A single ASCII character in the set 0-9, *, #, A, B, C, D.
<duration>
Tone duration in 1/10 seconds, from 0 to 255. This is interpreted as a DTMF tone of different
duration from that mandated by the AT+VTD command, otherwise, the duration which be set the
AT+VTD command will be used for the tone (<duration> is omitted).
<dtmf-string>
A sequence of ASCII character in the set 0-9, *, #, A, B, C, D, and maximal length of the string is
29. The string must be enclosed in double quotes (“”), and separated by commas between the ASCII
characters (e.g. “1,3,5,7,9,*”). Each of the tones with a duration which is set by the AT+VTD
command.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
217
2019-11-21
Smart Machine Smart Decision
Examples
ia
lF
ile
AT+VTS=1
OK
AT+VTS=1,20
OK
AT+VTS=”1,3,5”
OK
AT+VTS=?
+VTS: (0-9,*,#,A,B,C,D)
OK
nt
13.16 AT+VTD Tone duration
Description
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+VTD=?
C
om
Read Command
AT+VTD?
C
on
f
SIM PIN
id
e
This refers to an integer <n> that defines the length of tones emitted as a result of the AT+VTS
command. A value different than zero causes a tone of duration <n>/10 seconds.
Write Command
AT+VTD=<n>
Responses
+VTD: (list of supported <n>s)
OK
Responses
+VTD: <n>
OK
Responses
OK
Defined values
SI
M
<n>
Tone duration in integer format, from 0 to 255, and 0 is factory value.
0
Tone duration of every single tone is dependent on the network.
1…255 Tone duration of every single tone in 1/10 seconds.
Examples
AT+VTD=?
+VTD: (0-255)
SIM7906_SIM7912 Series_AT Command Manual_V1.01
218
2019-11-21
Smart Machine Smart Decision
13.17
lF
ile
OK
AT+VTD?
+VTD: 0
OK
AT+VTD=5
OK
AT+CSTA Select type of address
ia
Description
YES
References
id
e
SIM PIN
nt
Write command is used to select the type of number for further dialing commands (ATD) according
to GSM/UMTS specifications.
Read command returns the current type of number.
Test command returns values supported by the Module as a compound value.
3GPP TS 27.007
Test Command
AT+CSTA=?
C
on
f
Syntax
Write Command
AT+CSTA=<type>
Responses
+CSTA:(list of supported <type>s)
OK
Responses
+CSTA:<type>
OK
Responses
OK
Execution Command
AT+CSTA
ERROR
Responses
OK
C
om
Read Command
AT+CSTA?
Defined values
SI
M
<type>
Type of address octet in integer format:
145 – when dialling string includes international access code character “+”
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
129 – otherwise
NOTE: Because the type of address is automatically detected on the dial string of dialing
command, command AT+CSTA has really no effect.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
219
2019-11-21
Smart Machine Smart Decision
Examples
13.18
lF
ile
AT+CSTA?
+CSTA: 129
OK
AT+CSTA=145
OK
AT+CMOD Call mode
ia
Description
NO
References
id
e
SIM PIN
nt
Write command selects the call mode of further dialing commands (ATD) or for next answering
command (ATA). Mode can be either single or alternating.
Test command returns values supported by the TA as a compound value.
3GPP TS 27.007
Syntax
Read Command
AT+CMOD?
Responses
+CMOD: (list of supported <mode>s)
OK
C
on
f
Test Command
AT+CMOD=?
C
om
Write Command
AT+CMOD=<mode>
Execution Command
AT+CMOD
Responses
+CMOD: <mode>
OK
Responses
OK
ERROR
Responses
Set default value:
OK
SI
M
Defined values
<mode>
0 – single mode(only supported)
NOTE: The value of <mode> shall be set to zero after a successfully completed alternating mode
call. It shall be set to zero also after a failed answering. The power-on, factory and user resets shall
also set the value to zero. This reduces the possibility that alternating mode calls are originated or
answered accidentally.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
220
2019-11-21
Smart Machine Smart Decision
Examples
13.19 AT+CSDVC
lF
ile
AT+CMOD?
+CMOD: 0
OK
AT+CMOD=0
OK
Switch voice channel device
ia
Description
NO
References
Vendor
Syntax
Test Command
AT+CSDVC=?
Read Command
AT+CSDVC?
C
on
f
SIM PIN
id
e
nt
This command is used to switch voice channel device. After changing current voice channel device
and if there is a connecting voice call, it will use the settings of previous device (loudspeaker
volume level, mute state of loudspeaker and microphone, refer to AT+CLVL, AT+VMUTE, and
AT+CMUT).
C
om
Write Command
AT+CSDVC=<dev>
Responses
+CSDVC: (list of supported <dev>s)
OK
Responses
+CSDVC: <dev>
OK
Responses
OK
Defined values
SI
M
<dev>
0 – close voice channel device. only used after AT+CODECCTL=1
1 – handset
3 – speaker phone
Examples
AT+CSDVC=1
OK
AT+CSDVC?
+CSDVC:1
SIM7906_SIM7912 Series_AT Command Manual_V1.01
221
2019-11-21
Smart Machine Smart Decision
OK
lF
ile
13.20 AT+CLVL Loudspeaker volume level
Description
Write command is used to select the volume of the internal loudspeaker audio output of the device.
Test command returns supported values as compound value.
NO
References
3GPP TS 27.007
ia
SIM PIN
nt
Syntax
Responses
+CLVL: (list of supported <level>s)
OK
Read Command
AT+CLVL?
Responses
+CLVL: <level>
OK
C
on
f
id
e
Test Command
AT+CLVL=?
Write Command
AT+CLVL=<level>
Responses
OK
ERROR
Defined values
C
om
<level>
Integer type value which represents loudspeaker volume level. The range is from 0 to 5, and 0
represents the lowest loudspeaker volume level, 4 is default factory value.
NOTE: <level> is nonvolatile, and it is stored when restart.
Examples
SI
M
AT+CLVL?
+CLVL:4
OK
AT+CLVL=3
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
222
2019-11-21
Smart Machine Smart Decision
13.21 AT+SIDET Set sidetone
lF
ile
Description
This command is used to enable or disable sidetone. Please refer to related hardware design
document for more information. This command is only used after call start.
NO
References
Vendor
Syntax
Responses
+SIDET: (list of supported <en>s)
OK
Read Command
AT+SIDET?
Responses
+SIDET: <en>
OK
Write Command
AT+SIDET=<en>
Responses
OK
C
on
f
id
e
nt
Test Command
AT+SIDET=?
ia
SIM PIN
ERROR
Defined values
C
om
<en>
0: disable sidetone
1: enable sidetone
Examples
SI
M
AT+SIDET?
+SIDET: 0
OK
AT+SIDET=?
+SIDET: (0-1)
OK
AT+SIDET=1
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
223
2019-11-21
Smart Machine Smart Decision
lF
ile
14 AT Command for Hardware
14.1 AT+CBC Read the voltage value of the power supply
Description
This command is used to read the voltage value of the power supply
ia
NO
References
Vendor
Syntax
Responses
+CBC: <vol>
OK
Defined values
C
on
f
ERROR
id
e
Read Command
AT+CBC
nt
SIM PIN
<vol>
The voltage value, such as 3.8.
Examples
C
om
AT+CBC
+CBC: 3.591V
OK
14.2 AT+CVALARM Low and high voltage Alarm
M
Description
SI
This command is used to open or close the low voltage alarm function.
SIM PIN
NO
References
Vendor
Syntax
SIM7906_SIM7912 Series_AT Command Manual_V1.01
224
2019-11-21
Smart Machine Smart Decision
Responses
AT+CVALARM=?
+CVALARM: (list of supported <enable>s), (list of supported <
<low voltage>s), (list of supported high < high voltage>s)
OK
Read Command
Responses
AT+CVALARM?
+CVALARM: <enable>,<low voltage>, <high voltage>
OK
Write Command
Responses
AT+CVALARM=<enable>[,<l
ow voltage>],[<high voltage>]
OK
lF
ile
Test Command
ia
ERROR
nt
Defined values
Examples
C
on
f
id
e
<enable>
0 – Close
1 – Open. If voltage < < low voltage>, it will report “UNDER-VOLTAGE WARNNING”
every 10s. If voltage > <high voltage>, it will report “OVER-VOLTAGE
WARNNING” every 10s.
<low voltage>
Between 3200mV and 4000mV. Default value is 3200.
<high voltage>
Between 4000mV and 4350mV. Default value is 4350.
NOTE:The three parameters will be saved automatically.
M
C
om
AT+CVALARM=1,3400,4300
OK
AT+CVALARM?
+CVALARM: 1,3400,4300
OK
AT+CVALARM=?
+CVALARM: (0,1),(3200-4000),(4000-4350)
OK
SI
14.3 AT+CPMVT Low and high voltage Power Off
Description
This command is used to open or close the low and high voltage power off function.
SIM PIN
References
SIM7906_SIM7912 Series_AT Command Manual_V1.01
225
2019-11-21
Smart Machine Smart Decision
NO
Vendor
lF
ile
Syntax
Responses
+CPMVT: (list of supported <enable>s), (list of supported < low
voltage>s), (list of supported < high voltage>s)
OK
Read Command
AT+CPMVT?
Responses
+CPMVT: <enable>,<low voltage>, <high voltage>
OK
Write Command
AT+CPMVT=<enable>[,<low
voltage>],[<high voltage>]
Responses
OK
nt
id
e
ERROR
ia
Test Command
AT+CPMVT=?
Defined values
C
on
f
<enable>
0 – Close
1 – Open. If voltage < < low voltage>, it will report “UNDER-VOLTAGE WARNNING
POWER DOWN” and power off the module. If voltage > <high voltage>, it will report
“OVER-VOLTAGE WARNNING POWER DOWN” and power off the module
<low voltage>
Between 3100mV and 4000mV. Default value is 3100.
<high voltage>
Between 4000mV and 4300mV. Default value is 4420.
C
om
Examples
SI
M
AT+CPMVT=1,3400,4300
OK
AT+CPMVT?
+CPMVT: 1,3400,4300
OK
AT+CPMVT=?
+CPMVT: (0-1),(3100-4000),(4000-4420)
OK
14.4 AT+CPMUTEMP Read the temperature of the module
Description
SIM7906_SIM7912 Series_AT Command Manual_V1.01
226
2019-11-21
Smart Machine Smart Decision
This command is used to read the temperature of the module
NO
References
Vendor
lF
ile
SIM PIN
Syntax
Read Command
AT+CPMUTEMP
Responses
+CPMUTEMP: <temp>
OK
ia
ERROR
nt
Defined values
id
e
<temp>
The Temperature value, such as 29.
Examples
C
on
f
AT+CPMUTEMP
+CPMUTEMP: 29
OK
14.5 AT+CADC0
Description
Read ADC0 value
C
om
This command is used to read the ADC0 value from modem. ME supports 2 types of ADC0, which
are raw type and voltage type.
SIM PIN
NO
References
Vendor
Syntax
Responses
AT+CADC0=?
+CADC0: (range of supported <adc>s)
OK
Write Command
Responses
AT+CADC0=<adc>
+CADC0: <value>
OK
SI
M
Test Command
ERROR
SIM7906_SIM7912 Series_AT Command Manual_V1.01
227
2019-11-21
Smart Machine Smart Decision
Defined values
lF
ile
<adc>
ADC0 type:
0 – raw type.
2 – voltage type(mv)
<value>
Integer type value of the ADC0.
Examples
Description
Read ADC1 value
C
on
f
14.6 AT+CADC1
id
e
nt
ia
AT+CADC0=?
+CADC0: (0,2)
OK
AT+CADC0=0
+CADC0: 187
OK
This command is used to read the ADC1 value from modem. ME supports 2 types of ADC1, which
are raw type and voltage type.
SIM PIN
NO
References
Vendor
C
om
Syntax
Responses
+CADC1: (range of supported <adc>s)
OK
Write Command
AT+CADC1=<adc>
Responses
+CADC1: <value>
OK
SI
M
Test Command
AT+CADC1=?
ERROR
Defined values
<adc>
ADC1 type:
0 – raw type.
SIM7906_SIM7912 Series_AT Command Manual_V1.01
228
2019-11-21
Smart Machine Smart Decision
lF
ile
2 – voltage type(mv)
<value>
Integer type value of the ADC1.
Examples
Read ADC2 value
id
e
14.7 AT+CADC2
nt
ia
AT+CADC1=?
+CADC1: (0,2)
OK
AT+CADC1=0
+CADC1: 187
OK
Description
This command is used to read the ADC2 value from modem. ME supports 2 types of ADC2, which
are raw type and voltage type.
NO
References
C
on
f
SIM PIN
Vendor
Syntax
C
om
Test Command
AT+CADC2=?
Write Command
AT+CADC2=<adc>
Responses
+CADC2: (range of supported <adc>s)
OK
Responses
+CADC2: <value>
OK
ERROR
SI
M
Defined values
<adc>
ADC2 type:
0 – raw type.
2 – voltage type(mv)
<value>
Integer type value of the ADC2.
Examples
SIM7906_SIM7912 Series_AT Command Manual_V1.01
229
2019-11-21
Smart Machine Smart Decision
lF
ile
AT+CADC2=?
+CADC2: (0,2)
OK
AT+CADC2=0
+CADC2: 187
OK
AT+CVAUS Set state of the pin named VREG_L14_SDC
14.8
ia
Description
This command is used to set state of the pin which is named VREG_L14_SDC.
nt
NO
References
Vendor
id
e
SIM PIN
Syntax
Read Command
AT+CVAUS?
Responses
+CVAUS: (list of supported <state>s)
OK
C
on
f
Test Command
AT+CVAUS=?
Write Command
AT+CVAUS=<state>
Responses
+CVAUS: <state>
OK
Responses
OK
C
om
ERROR
Defined values
<state>
0 –
1 –
the pin is closed.
the pin is opend(namely, open the pin)
SI
M
Examples
AT+CVAUS=1
OK
AT+CVAUS?
+CVAUS: 1
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
230
2019-11-21
Smart Machine Smart Decision
AT+CVAUV Set microvolt of the pin named VREG_L14_SDC
14.9
lF
ile
Description
This command is used to set the voltage value of the pin which is named VREG_L14_SDC.
SIM PIN
NO
References
Vendor
ia
Syntax
Responses
+CVAUV: (list of supported <voltage>s)
OK
Read Command
AT+CVAUV?
Responses
+CVAUV: <voltage>
OK
Write Command
AT+CVAUV=<voltage>
Responses
OK
Defined values
id
e
C
on
f
ERROR
nt
Test Command
AT+CVAUV=?
<voltage>
Voltage value of the pin which is named VREG_L14_SDC. The unit is in mV. And the value must
the multiple of 50mv.
C
om
Examples
SI
M
AT+CVAUV=?
+CVAUV: (1800-2850)
OK
AT+CVAUV=2800
OK
AT+CVAUV?
+CVAUV: 2800
OK
SIM7906_SIM7912 Series_AT Command Manual_V1.01
231
2019-11-21
Smart Machine Smart Decision
Numeric (V0 set)
Description
OK
0
Command executed, no errors, Wake up after reset
CONNECT
1
Link established
RING
2
Ring detected
NO CARRIER
3
Link not established or disconnected
ERROR
4
Invalid command or command line too long
NO DIALTONE
6
No dial tone, dialing impossible, wrong mode
BUSY
7
Remote station busy
NO ANSWER
8
nt
id
e
Connection completion timeout
Response string of AT+CEER
Number
CS internal cause
0
21
25
27
29
34
35
36
38
29
45
46
47
48
100
101
102
103
104
105
M
SI
ia
Verbose result code
C
om
15.2
Verbose code and numeric code
C
on
f
15.1
lF
ile
15 Appendixes
Response string
Phone is offline
No service available
Network release, no reason given
Received incoming call
Client ended call
UIM not present
Access attempt already in progress
Access failure, unknown source
Concur service not supported by network
No response received from network
GPS call ended for user call
SMS call ended for user call
Data call ended for emergency call
Rejected during redirect or handoff
Lower-layer ended call
Call origination request failed
Client rejected incoming call
Client rejected setup indication
Network ended call
No funds available
SIM7906_SIM7912 Series_AT Command Manual_V1.01
232
2019-11-21
No service available
Full service not available
Maximum packet calls exceeded
Video connection lost
Video call setup failure
Video protocol closed after setup
Video protocol setup failure
Internal error
CS network cause
1
3
6
8
16
17
18
19
21
22
26
27
28
29
30
31
34
38
41
42
43
44
47
49
50
55
57
58
63
65
68
69
70
Unassigned/unallocated number
No route to destination
Channel unacceptable
Operator determined barring
Normal call clearing
User busy
No user responding
User alerting, no answer
Call rejected
Number changed
Non selected user clearing
Destination out of order
Invalid/incomplete number
Facility rejected
Response to Status Enquiry
Normal, unspecified
No circuit/channel available
Network out of order
Temporary failure
Switching equipment congestion
Access information discarded
Requested circuit/channel not available
Resources unavailable, unspecified
Quality of service unavailable
Requested facility not subscribed
Incoming calls barred within the CUG
Bearer capability not authorized
Bearer capability not available
Service/option not available
Bearer service not implemented
ACM >= ACMmax
Requested facility not implemented
Only RDI bearer is available
SI
M
C
om
C
on
f
id
e
nt
ia
106
108
109
301
302
303
304
305
lF
ile
Smart Machine Smart Decision
SIM7906_SIM7912 Series_AT Command Manual_V1.01
233
2019-11-21
Service/option not implemented
Invalid transaction identifier value
User not member of CUG
Incompatible destination
Invalid transit network selection
Semantically incorrect message
Invalid mandatory information
Message non-existent/not implemented
Message type not compatible with state
IE non-existent/not implemented
Conditional IE error
Message not compatible with state
Recovery on timer expiry
Protocol error, unspecified
Interworking, unspecified
CS network reject
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
20
21
22
23
32
33
34
38
40
95
IMSI unknown in HLR
Illegal MS
IMSI unknown in VLR
IMEI not accepted
Illegal ME
GPRS services not allowed
GPRS & non GPRS services not allowed
MS identity cannot be derived
Implicitly detached
PLMN not allowed
Location Area not allowed
Roaming not allowed
GPRS services not allowed in PLMN
No Suitable Cells In Location Area
MSC temporarily not reachable
Network failure
MAC failure
Synch failure
Congestion
GSM authentication unacceptable
Service option not supported
Requested service option not subscribed
Service option temporarily out of orde
Call cannot be identified
No PDP context activated
Semantically incorrect message
SI
M
C
om
C
on
f
id
e
nt
ia
79
81
87
88
91
95
96
97
98
99
100
101
102
111
117
lF
ile
Smart Machine Smart Decision
SIM7906_SIM7912 Series_AT Command Manual_V1.01
234
2019-11-21
ia
nt
id
e
C
om
PS internal cause lookup
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
M
SI
Invalid mandatory information
Message type non-existent
Message type not compatible with state
Information element non-existent
Message not compatible with state
RR release indication
RR random access failure
RRC release indication
RRC close session indication
RRC open session failure
Low level failure
Low level failure no redial allowed
Invalid SIM
No service
Timer T3230 expired
No cell available
Wrong state
Access class blocked
Abort message received
Other cause
Timer T303 expired
No resources
Release pending
Invalid user data
C
on
f
96
97
98
99
101
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
lF
ile
Smart Machine Smart Decision
Invalid connection identifier
Invalid NSAPI
Invalid Primary NSAPI
Invalid field
SNDCP failure
RAB setup failure
No GPRS context
PDP establish timeout
PDP activate timeout
PDP modify timeout
PDP inactive max timeout
PDP lowerlayer error
PDP duplicate
Access technology change
PDP unknown reason
PS network cause
SIM7906_SIM7912 Series_AT Command Manual_V1.01
235
2019-11-21
15.3
id
e
nt
ia
LLC or SNDCP failure
Insufficient resources
Missing or unknown APN
Unknown PDP address or PDP type
User Authentication failed
Activation rejected by GGSN
Activation rejected, unspecified
Service option not supported
Requested service option not subscribed
Service option temporarily out of order
NSAPI already used (not sent)
Regular deactivation
QoS not accepted
Network failure
Reactivation required
Feature not supported
Semantic error in the TFT operation
Syntactical error in the TFT operation
Unknown PDP context
PDP context without TFT already activated
Semantic errors in packet filter
Syntactical errors in packet filter
Invalid transaction identifier
Semantically incorrect message
Invalid mandatory information
Message non-existent/not implemented
Message type not compatible with state
IE non-existent/not implemented
Conditional IE error
Message not compatible with state
Protocol error, unspecified
C
on
f
C
om
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
81
95
96
97
98
99
100
101
111
lF
ile
Smart Machine Smart Decision
Summary of CME ERROR codes
SI
M
Description
This result code is similar to the regular ERROR result code. The format of <err> can be either
numeric or verbose string, by setting AT+CMEE command.
SIM PIN
NO
References
3GPP TS 27.007
Syntax
SIM7906_SIM7912 Series_AT Command Manual_V1.01
236
2019-11-21
Smart Machine Smart Decision
+CME ERROR: <err>
lF
ile
Defined values
SI
M
C
om
C
on
f
id
e
nt
ia
<err>
Values (numeric format followed by verbose format):
0
phone failure
1
no connection to phone
2
phone adaptor link reserved
3
operation not allowed
4
operation not supported
5
PH-SIM PIN required
6
PH-FSIM PIN required
7
PH-FSIM PUK required
10
SIM not inserted
11
SIM PIN required
12
SIM PUK required
13
SIM failure
14
SIM busy
15
SIM wrong
16
incorrect password
17
SIM PIN2 required
18
SIM PUK2 required
20
memory full
21
invalid index
22
not found
23
memory failure
24
text string too long
25
invalid characters in text string
26
dial string too long
27
invalid characters in dial string
30
no network service
31
network timeout
32
network not allowed - emergency calls only
40
network personalization PIN required
41
network personalization PUK required
42
network subset personalization PIN required
43
network subset personalization PUK required
44
service provider personalization PIN required
45
service provider personalization PUK required
46
corporate personalization PIN required
47
corporate personalization PUK required
100
Unknown
SIM7906_SIM7912 Series_AT Command Manual_V1.01
237
2019-11-21
SI
ia
nt
M
C
om
C
on
f
id
e
103
Illegal MESSAGE
106
Illegal ME
107
GPRS services not allowed
111
PLMN not allowed
112
Location area not allowed
113
Roaming not allowed in this location area
132
service option not supported
133
requested service option not subscribed
134
service option temporarily out of order
148
unspecified GPRS error
149
PDP authentication failure
150
invalid mobile class
257
network rejected request
258
retry operation
259
invalid deflected to number
260
deflected to own number
261
unknown subscriber
262
service not available
263
unknown class specified
264
unknown network message
273
minimum TFTS per PDP address violated
274
TFT precedence index not unique
275
invalid parameter combination
“CME ERROR” codes of MMS:
170
Unknown error for mms
171
MMS task is busy now
172
The mms data is over size
173
The operation is overtime
174
There is no mms receiver
175
The storage for address is full
176
Not find the address
177
Invalid parameter
178
Failed to read mss
179
There is not a mms push message
180
Memory error
181
Invalid file format
182
The mms storage is full
183
The box is empty
184
Failed to save mms
185
It’s busy editing mms now
186
It’s not allowed to edit now
187
No content in the buffer
188
Failed to receive mms
lF
ile
Smart Machine Smart Decision
SIM7906_SIM7912 Series_AT Command Manual_V1.01
238
2019-11-21
ia
nt
id
e
189
Invalid mms pdu
190
Network error
191
Failed to read file
192
None
“CME ERROR” codes of FTP:
201
Unknown error for FTP
202
FTP task is busy
203
Failed to resolve server address
204
FTP timeout
205
Failed to read file
206
Failed to write file
207
It’s not allowed in current state
208
Failed to login
209
Failed to logout
210
Failed to transfer data
211
FTP command rejected by server
212
Memory error
213
Invalid parameter
214
Network error
lF
ile
Smart Machine Smart Decision
C
on
f
Examples
AT+CPIN="1234","1234"
+CME ERROR: incorrect password
15.4
Summary of CMS ERROR codes
C
om
Description
Final result code +CMS ERROR: <err> indicates an error related to mobile equipment or network.
The operation is similar to ERROR result code. None of the following commands in the same
command line is executed. Neither ERROR nor OK result code shall be returned. ERROR is
returned normally when error is related to syntax or invalid parameters. The format of <err> can be
either numeric or verbose. This is set with command AT+CMEE.
M
SIM PIN
---
References
3GPP TS 27.005
SI
Syntax
+CMS ERROR: <err>
Defined values
<err>
SIM7906_SIM7912 Series_AT Command Manual_V1.01
239
2019-11-21
Examples
ia
nt
id
e
ME failure
SMS service of ME reserved
Operation not allowed
Operation not supported
Invalid PDU mode parameter
Invalid text mode parameter
SIM not inserted
SIM PIN required
PH-SIM PIN required
SIM failure
SIM busy
SIM wrong
SIM PUK required
SIM PIN2 required
SIM PUK2 required
Memory failure
Invalid memory index
Memory full
SMSC address unknown
no network service
Network timeout
NO +CNMA ACK EXPECTED
Buffer overflow
SMS size more than expected
unknown error
C
on
f
300
301
302
303
304
305
310
311
312
313
314
315
316
317
318
320
321
322
330
331
332
340
341
342
500
lF
ile
Smart Machine Smart Decision
SI
M
C
om
AT+CMGS=02112345678
+CMS ERROR: 304
SIM7906_SIM7912 Series_AT Command Manual_V1.01
240
2019-11-21
Smart Machine Smart Decision
Contact us:
Shanghai SIMCom Wireless Solutions Ltd.
SI
M
C
om
C
on
f
id
e
nt
ia
lF
ile
Add: Building B, SIM Technology Building, No.633, Jinzhong Road, Changning District
200335
Tel: +86 21 3157 5100\3157 5200
Email: [email protected]
Website: www.simcom.com
SIM7906_SIM7912 Series_AT Command Manual_V1.01
241
2019-11-21
">
/
Downloaden
Even een vriendelijke herinnering. U kunt het document hier bekijken. Maar het belangrijkste is dat onze AI het al heeft gelezen. Het kan complexe dingen in eenvoudige bewoordingen uitleggen, uw vragen in elke taal beantwoorden en u helpen snel te navigeren, zelfs in de langste of meest ingewikkelde documenten.