SimCom SIM7600 Series At Command Manual
PDF
Dokument
Annonce
Annonce
E
FI
L
AL
Series_AT
SI
M
C
O
M
C
O
N
FI
D
EN
TI
SIM7500_SIM7600
Command Manual _V1.07
SIM7500_SIM7600 Series_AT Command Manual
Version:
1.07
Date:
2017-12-25
Status:
Release
Document ID:
SIM7500_SIM7600 Series_AT Command Manual_V1.07
FI
L
Document Title:
E
Smart Machine Smart Decision
AL
General Notes
FI
D
EN
TI
SIMCom offers this information as a service to its customers, to support application and engineering efforts
that use the products designed by SIMCom. The information provided is based upon requirements
specifically provided to SIMCom by the customers. SIMCom has not undertaken any independent search
for additional relevant information, including any information that may be in the customer’s possession.
Furthermore, system validation of this product designed by SIMCom within a larger electronic system
remains the responsibility of the customer or the customer’s system integrator. All specifications supplied
herein are subject to change.
Copyright
C
O
N
This document contains proprietary technical information which is the property of SIMCom Limited.,
copying of this document and giving it to others and the using or communication of the contents thereof,
are forbidden without express authority. Offenders are liable to the payment of damages. All rights reserved
in the event of grant of a patent or the registration of a utility model or design. All specification supplied
herein are subject to change without notice at any time.
SI
M
C
O
M
Copyright © Shanghai SIMCom Wireless Solutions Ltd. 2017
SIM7500_SIM7600 Series_AT Command Manual_V1.07
1
2017-12-25
Smart Machine Smart Decision
V1.00
2016-07-08
V1.01
2016-07-21
5.5 AT+CCUG
Add note.
V1.01
2016-07-21
5.6 AT+CUSD
Add note.
V1.01
2016-07-21
5.7 AT+CAOC
Add note.
V1.01
2016-07-21
5.8 AT+CSSN
Add note.
V1.01
2016-07-21
11.2 AT+STGI
Add PDU format support
V1.01
2016-07-21
11.3 AT+STGR
Add PDU format support
V1.01
2016-07-21
11.6 AT+STENV
Add this command
V1.01
2016-07-21
11.7 AT+STSM
V1.02
2016-07-27
11.7 AT+STSM
V1.02
2016-07-27
5.13 AT+CNAOP
V1.02
2016-07-27
5.18 AT+CTZU
Modify this command
V1.02
2016-07-27
5.19 AT+CTZR
Modify this command
V1.02
2016-07-27
5.16 AT+CPSI
Modify this command
V1.02
2016-07-27
9.15 AT+CGAUTH
Modify this command
V1.02
2016-07-27
Chapter 15
Delete the CSOCK* Command
V1.02
2016-07-27
3.21 AT&F
Modify this command
V1.02
2016-07-28
6.25 AT+CACDBFN
Modify this command
V1.02
2016-07-29
Modify this command
V1.02
M
5.18 AT+CTZU
2016-07-29
5.18 AT+CTZR
Modify this command
V1.02
2016-07-29
6.24 AT+SIDET
Modify this command
V1.02
2016-07-29
5.20 AT+NETMODE
Modify this command,PIN->NO
M
V1.02
2016-07-29
12.5 AT+CGFUNC
Modify this command
V1.02
2016-07-29
12.6 AT+CGDRT
Modify this command
V.1.02
2016-07-29
12.7 AT+CGGRTV
Modify this command
V.1.02
2016-07-29
12.8 AT+CGSETV
Modify this command
V1.02
2016-07-29
5.15 AT+CPSI
Modify this command
V1.02
2016-07-29
11.2 AT+STGI
Modify this command
V1.02
2016-07-29
11.7 AT+STSM
Modify this command
C
Chapter
What is new
E
Date
O
Version
SI
Version History
EN
TI
AL
FI
L
New version
Add this command
C
O
N
FI
D
Modify this command
SIM7500_SIM7600 Series_AT Command Manual_V1.07
Modify this command
2
2017-12-25
V1.02
2016-07-29
Delete CSD function
Delete CSD function
V1.02
2016-08-05
11.5 AT+STKFMT
pdu format
Set STK Modify this command
V1.02
2016-08-05
5.15 AT+CPSI Inquiring UE Modify 1xlte
system information
V1.02
2016-08-05
9.11 AT+CGDATA
state
V1.02
2016-08-05
9.3 AT+CGACT PDP context Modify cid
activate or deactivate
V1.02
2016-08-05
7.9
AT+CNMI New message Modify default value
indications to TE
V1.02
2016-08-12
7.25
AT+CMGP
Set Modify format
cdma/evdo text mode parameters
V1.02
2016-08-16
15.7 Common Channel Service
Modify these commands
15.8
SSL Certificate & Key
management
V1.02
2016-08-16
6.29 AT+CTXVOL
6.30 AT+CTXMICGAIN
V1.02
2016-08-17
11.7 AT+STSM Get STK Setup Modify this command
Menu List with PDU Mode
V1.02
2016-08-17
5.14
AT+CNSDP
Preferred Delete this command
service domain selection
V1.02
2016-08-19
O
Smart Machine Smart Decision
AT+CMGENREF
AT+CMSSEXM
AT+CSALPHA
Delete this command
V1.02
2016-08-26
15.1.6 AT+CPINGSTOP
Modify this command
V1.02
2016-08-30
5.19 AT+NETMODE
Modify this command
V1.02
2016-09-05
3.21 AT&F
Modify this command
E
FI
L
AL
EN
TI
M
C
N
FI
D
Add commands
2016-09-05
10.6 AT+CMTE
Modify test command
V1.02
2016-09-05
15.7.3 AT+CCHOPEN
15.7.7 AT+CCHSET
15.7.8 AT+CCHADDR
Modify these commands
V1.02
2016-09-05
15.7.10
Unsolicited common Add error code description
channel command <err> Codes
V1.02
2016-09-06
6.27
6.28
6.29
6.30
V1.02
2016-09-06
6.31 AT+CRXVOL
SI
M
V1.02
C
O
Enter data Modify cid
AT+CMICGAIN
AT+COUTGAIN
AT+CTXVOL
AT+CTXMICGAIN
SIM7500_SIM7600 Series_AT Command Manual_V1.07
Modify these commands
Add these commands
3
2017-12-25
AT+CECH
AT+CECDT
AT+CECWB
AT+CNSN
AT+CNSLIM
AT+CFNSMOD
AT+CFNSIN
AT+CFNSLVL
AT+CGDRT
AT+CGSETV
AT+CGGETV
AT+CGISR
FI
L
6.32
6.33
6.34
6.35
6.36
6.37
6.38
6.39
E
Smart Machine Smart Decision
2016-09-06
12.6
12.7
12.8
12.9
Modify these commands
V1.02
2016-09-07
9.15 AT+CGAUTH
Modify read command and test command
V1.02
2016-09-09
5.11 AT+CNMP
Modify this command
V1.02
2016-09-09
3.21 AT&F
Modify this command
V1.02
2016-09-09
11.5 AT+STKFMT
V1.02
2016-09-13
6.24 AT+SIDET
V1.02
2016-09-13
4.23 AT+CUSBPIDSWITCH
Add this command
V1.02
2016-09-14
6.22 AT+CSDVC
Modify this command
V1.02
2016-09-18
6.40 AT+CECRX
6.41 AT+CNLPPG
6.42 AT+CNLPPL
Add these commands
V1.02
2016-09-19
7.2 AT+CPMS
V1.02
2016-09-21
V1.02
EN
TI
AL
V1.02
Modify this command
Modify this command
10.6 AT+CMTE
Modify this command
2016-09-21
10.9 AT+CUSBDELETEADB
Delete this command
V1.02
2016-09-22
6.43 AT+CECM
Add this command
V1.02
2016-09-22
15.7.6 AT+CCHRECV
Modify this command
M
O
2016-09-22
V1.02
2016-09-26
6.25 AT+CACDBFN
Modify this command
M
15.7.10
Unsolicited common Modify the format
channel command <err> Codes
V1.02
2016-09-27
15.2.10 AT+CIPFILTERSET
Modify this command
SI
C
V1.02
C
O
N
FI
D
Modify this command
V1.02
2016-09-28
3.33 AT+CIMI
Modify this command
V1.02
2016-09-28
3.34 AT+CIMIM
Add this command
V1.02
2016-09-28
7.13 AT+CMGS
7.15 AT+CMGW
7.20 AT+CMGSEX
Modify these commands
V1.02
2016-10-08
3.21 AT&F
Modify this command
SIM7500_SIM7600 Series_AT Command Manual_V1.07
4
2017-12-25
9.6 AT+CGTFT
Modify this command
V1.02
2016-10-13
9.4 AT+CGDCONT
Modify this command
V1.02
2016-10-13
16.8 AT+CGPSNMEA
Modify this command
V1.02
2016-10-17
9.3 AT+CGACT
9.7 AT+CGQREQ
9.8 AT+CGEQREQ
9.9 AT+CGQMIN
9.10 AT+CGEQMIN
9.11 AT+CGDATA
9.12 AT+CGPADDR
9.15 AT+CGAUTH
15.1.12 AT+CDNSSRV
Modify these commands
V1.02
2016-10-18
7.2 AT+CPMS
Modify this command
V1.02
2016-10-19
3.21 AT&F
Modify this command
V1.02
2016-10-20
9.8 AT+CGEQREQ
9.10 AT+CGEQMIN
Modify these commands
V1.02
2016-10-20
12.9 AT+CGISR
V1.02
2016-10-24
5.13 AT+CNAOP
V1.02
2016-10-24
3.21 AT&F
V1.02
2016-10-28
16.20 AT+CGPSMODE
Add this command
V1.02
2016-11-09
11.4 AT+STK
Modify this command
V1.02
2016-11-04
6.22 AT+CSDVC
Modify this command
V1.02
2016-11-04
16.21 AT+CBDS
Add this command
V1.02
2016-11-04
15.3.9 AT+CFTPGET
15.3.11 AT+CFTPLIST
Modify these commands
V1.02
2016-11-04
15.3.15 AT+CFTPCACHERD
Add this command
V1.02
2016-11-08
4.23 AT+CUSBPIDSWITCH
Modify this command
V1.02
2016-11-10
3.21 AT&F
Modify this command
FI
L
AL
TI
EN
Modify this command
Modify this command
V1.02
2016-11-10
9.3 AT+CGACT
9.11 AT+CGDATA
Modify these commands
M
C
O
N
FI
D
Modify this command
V1.02
2016-11-10
15.1.1 AT+CSOCKSETPN
Modify this command
SI
C
E
2016-10-12
O
V1.02
M
Smart Machine Smart Decision
V1.03
2016-11-11
4.23 AT+CUSBPIDSWITCH
Modify this command
V1.03
2016-11-17
16.21 AT+CBDS
Modify this command
V1.03
2016-11-17
16.15 AT+CGPSINFOCFG
Modify this command
V1.03
2016-11-24
15.3.9 AT+CFTPGET
15.3.11 AT+CFTPLIST
15.3.15 AT+CFTPCACHERD
Modify these commands
SIM7500_SIM7600 Series_AT Command Manual_V1.07
5
2017-12-25
Smart Machine Smart Decision
2016-11-24
15.7.3 AT+CCHOPEN
15.7.6 AT+CCHRECV
Modify these commands
V1.03
2016-12-12
9.3 AT+CGACT
Modify this command
V1.03
2016-12-21
9.4 AT+CGDCONT
Modify this command
V1.03
2016-12-23
3.21 AT&F
5.11 AT+CNBP
5.14 AT+CPSI
Modify these commands
V1.03
2017-1-4
9.12 AT+CGPADDR
Modify this command
V1.03
2017-1-11
16.10 AT+CGPSFTM
Modify this command
V1.03
2017-1-12
5.14 AT+CPSI
Modify this command
V1.04
2017-1-20
15.7.6 AT+CCHRECV
Modify this command
V1.04
2017-2-9
6.26 AT+CPCMREG
6.43 AT+CECM
Modify these commands
V1.04
2017-2-9
15.7.6 AT+CCHRECV
Modify this command
V1.04
2017-2-20
5.12 AT+CNBP
V1.04
2017-2-21
3.12 AT+IPR
12.1 AT+IPREX
V1.04
2017-3-8
3.21 AT&F
V1.04
2017-3-28
17.24 AT+CLBS
V1.04
2017-4-13
17.9 AT+CGPSNEMARATE
Add this command
V1.04
2017-4-14
15.5 HTTPS
Add this chapter
V1.04
2017-4-19
17.25 AT+CLBSCFG
Add this command
V1.04
2017-5-4
4.23 AT+CUSBPIDSWITCH
Modify this command
V1.04
2017-5-11
17.26 AT+CASSISTLOC
Add this command
V1.04
2017-5-17
EN
TI
AL
FI
L
E
V1.03
Modify this command
Modify this command
M
V1.04
2017-5-24
18 Audio Application Commands Add this chapter
V1.04
2017-5-25
15.7 SMTP
Delete this chapter
V1.04
2017-5-25
15.4
Add this chapter
V1.05
2017-6-19
15.6 HTTPS
V1.05
2017-7-3
16.4 Unsolicited CNETSTART/ Add this command
CNETSTOP Codes
V1.05
2017-7-3
17.24 AT+CLBS
17.25 AT+CLBSCFG
Modify these commands
V1.05
2017-7-10
14.2 AT+CFTRANTX
Modify this command
V1.05
2017-7-10
13
M
O
16
AT
Commands
Open/Close Network
C
Add this command
SI
C
O
N
FI
D
Modify these commands
FTPS
for Add this chapter
Modify HTTPS commands
AT Commands for File Modify the description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
6
2017-12-25
Smart Machine Smart Decision
2017-7-11
6.44 AT+CPCMFRM
Add this command
V1.05
2017-7-14
15.8.9 AT+CCERTVERIFY
Add this command
V1.05
2017-8-25
7.12 AT+CMGR
Modify this command
V1.05
2017-9-5
5.15 AT+CNSMOD
Modify this command
V1.05
2017-9-5
5.14 AT+CPSI
Modify this command
V1.06
2017-10-13
1.1
Modify scope
V1.06
2017-10-13
17.24 AT+CLBS
Modify this command
V1.07
2017-10-16
15.3.2 AT+CFTPMODE
Modify this command
V1.07
2017-10-16
15.6.4 AT+CHTTPSCLSE
Modify this command
V1.07
2017-11-3
7.9 AT+CNMI
Modify this command
V1.07
2017-11-7
12.2 AT+CFGRI
Modify this command
V1.07
2017-11-13
17.25 AT+CLBS
Modify this command
V1.07
2017-11-13
15.8 NTP
V1.07
2017-11-13
17.23 AT+CGNSSINFO
V1.07
2017-12-14
4.23 AT+CUSBPIDSWITCH
V1.07
2017-12-15
17.25 AT+CLBS
EN
TI
AL
Scope
FI
L
V1.05
E
System
Add this chapter
Modify this command
Modify this command
SI
M
C
O
M
C
O
N
FI
D
Add this command
SIM7500_SIM7600 Series_AT Command Manual_V1.07
7
2017-12-25
Smart Machine Smart Decision
Contents
V e r s i o n H i s t o r y ........................................................................................................................... 2
C o n t e n t s ............................................................................................................................................ 8
1 Introduction.................................................................................................................................... 17
References ............................................................................................................................................ 17
1.3
Terms and abbreviations ....................................................................................................................... 17
1.4
Definitions and conventions ................................................................................................................. 18
FI
L
E
1.2
AT Interface Synopsis .................................................................................................................... 20
Interface settings .................................................................................................................................. 20
2.2
AT command syntax ............................................................................................................................. 20
2.3
Information responses .......................................................................................................................... 21
AL
2.1
AT Commands According V.25TER .............................................................................................. 22
A/
Repeat last command.................................................................................................................... 22
3.2
ATD
Dial command .......................................................................................................................... 22
3.3
ATD><mem><n>
3.4
ATD><n>
Originate call from active memory (1)............................................................................. 25
3.5
ATD><str>
Originate call from active memory (2)........................................................................... 26
3.6
ATA Call answer ................................................................................................................................ 27
3.7
ATH
Disconnect existing call ............................................................................................................ 28
3.8
ATS0
Automatic answer incoming call ............................................................................................. 28
3.9
+++
Switch from data mode to command mode ............................................................................... 29
3.10
ATO
Switch from command mode to data mode .............................................................................. 30
3.11
ATI
Display product identification information ................................................................................ 30
3.12
AT+IPR
Set local baud rate temporarily ........................................................................................... 32
3.13
AT+ICF
Set control character framing .............................................................................................. 33
3.14
AT+IFC
Set local data flow control................................................................................................... 34
3.15
AT&C
Set DCD function mode......................................................................................................... 35
3.16
ATE
Enable command echo .............................................................................................................. 36
3.17
AT&V Display current configuration ................................................................................................ 36
3.18
AT&D
Set DTR function mode ......................................................................................................... 37
Set DSR function mode .......................................................................................................... 37
EN
3.1
C
3
Scope .................................................................................................................................................... 17
TI
2
1.1
AT&S
3.20
ATV Set result code format mode ..................................................................................................... 38
3.21
AT&F
Set all current parameters to manufacturer defaults ............................................................... 39
3.22
ATQ
Set Result Code Presentation Mode ......................................................................................... 40
3.23
ATX
Set CONNECT Result Code Format ........................................................................................ 40
3.24
AT\V Set CONNECT Result Code Format About Protocol .............................................................. 41
3.25
AT&E
3.26
AT&W Save the user setting to ME .................................................................................................. 43
3.27
ATZ
3.28
AT+CGMI
Request manufacturer identification ............................................................................... 44
3.29
AT+CGMM
Request model identification ........................................................................................ 45
M
3.19
SI
O
M
C
O
N
FI
D
Originate call from specified memory ................................................................. 24
Set CONNECT Result Code Format About Speed ................................................................ 42
Restore the user setting from ME.............................................................................................. 43
SIM7500_SIM7600 Series_AT Command Manual_V1.07
8
2017-12-25
Smart Machine Smart Decision
3.31
AT+CGSN
Request product serial number identification ................................................................. 46
3.32
AT+CSCS
Select TE character set .................................................................................................... 47
3.33
AT+CIMI
Request international mobile subscriber identity ............................................................. 48
3.34
AT+CIMIM
Request another international mobile subscriber identity ............................................. 48
3.35
AT+GCAP Request overall capabilities ............................................................................................ 49
E
Request revision identification ...................................................................................... 45
AT Commands for Status Control .................................................................................................. 51
AT+CFUN
Set phone functionality ................................................................................................... 51
4.2
AT+CPIN
Enter PIN.......................................................................................................................... 52
4.3
AT+CICCID
Read ICCID from SIM card......................................................................................... 53
4.4
AT+CSIM
Generic SIM access ......................................................................................................... 54
4.5
AT+CRSM
Restricted SIM access .................................................................................................... 55
4.6
AT+SPIC Times remain to input SIM PIN/PUK ............................................................................... 59
4.7
AT+CSPN
Get service provider name from SIM .............................................................................. 60
4.8
AT+CSQ
Query signal quality .......................................................................................................... 61
4.9
AT+AUTOCSQ
4.10
AT+CSQDELTA Set RSSI delta change threshold ............................................................................ 63
4.11
AT+CATR
Configure URC destination interface .............................................................................. 64
4.12
AT+CPOF
Power down the module .................................................................................................. 65
4.13
AT+CRESET
Reset the module ........................................................................................................ 66
4.14
AT+CACM
Accumulated call meter ................................................................................................. 66
4.15
AT+CAMM
Accumulated call meter maximum ............................................................................... 67
4.16
AT+CPUC
Price per unit and currency table..................................................................................... 68
4.17
AT+CCLK
Real time clock management .......................................................................................... 69
4.18
AT+CMEE
Report mobile equipment error ...................................................................................... 70
4.19
AT+CPAS
Phone activity status ........................................................................................................ 71
4.20
AT+SIMEI
Set IMEI for the module ................................................................................................. 72
4.21
AT+SMEID
Request Mobile Equipment Identifier ........................................................................... 73
4.22
AT+CSVM
Voice Mail Subscriber number ....................................................................................... 74
4.23
AT+CUSBPIDSWITCH
4.24
Indication of EONS .............................................................................................................................. 76
4.25
Indication of Voice Mail ....................................................................................................................... 76
TI
AL
FI
L
4.1
M
C
O
N
FI
D
EN
Set CSQ report........................................................................................................ 62
Change module’s PID................................................................................ 75
AT Commands for Network ........................................................................................................... 77
C
5
AT+CGMR
O
4
3.30
AT+CREG
Network registration ....................................................................................................... 77
5.2
AT+COPS
Operator selection ........................................................................................................... 78
5.3
AT+CLCK
Facility lock .................................................................................................................... 81
5.4
AT+CPWD
Change password ........................................................................................................... 82
5.5
AT+CCUG
Closed user group ........................................................................................................... 84
5.6
AT+CUSD
Unstructured supplementary service data ....................................................................... 85
5.7
AT+CAOC
Advice of charge ............................................................................................................ 86
5.8
AT+CSSN
Supplementary service notifications................................................................................ 87
5.9
AT+CPOL Preferred operator list ...................................................................................................... 89
5.10
AT+COPN
SI
M
5.1
Read operator names ...................................................................................................... 91
SIM7500_SIM7600 Series_AT Command Manual_V1.07
9
2017-12-25
Smart Machine Smart Decision
AT+CNMP Preferred mode selection ................................................................................................ 92
5.12
AT+CNBP Preferred band selection .................................................................................................. 93
5.13
AT+CNAOP Acquisitions order preference ...................................................................................... 96
5.14
AT+CPSI
5.15
AT+CNSMOD
Show network system mode ................................................................................... 101
5.16
AT+CEREG
EPS network registration status .................................................................................. 102
5.17
AT+CTZU
Automatic time and time zone update........................................................................... 104
5.18
AT+CTZR
Time and time zone reporting ....................................................................................... 105
5.19
AT+NETMODE
FI
L
E
Inquiring UE system information ..................................................................................... 97
WCDMA & TDSCDMA mode select .................................................................. 106
AT Commands for Call Control ................................................................................................... 108
AT+CVHU
Voice hang up control .................................................................................................. 108
6.2
AT+CHUP Hang up call .................................................................................................................. 109
6.3
AT+CBST
6.4
AT+CRLP Radio link protocol ......................................................................................................... 111
6.5
AT+CR
Service reporting control.....................................................................................................112
6.6
AT+CRC
Cellular result codes .........................................................................................................114
6.7
AT+CLCC
List current calls.............................................................................................................115
6.8
AT+CEER
Extended error report .....................................................................................................117
6.9
AT+CCWA Call waiting ...................................................................................................................118
6.10
AT+CHLD
Call related supplementary services ..............................................................................119
6.11
AT+CCFC
Call forwarding number and conditions ........................................................................ 121
6.12
AT+CLIP Calling line identification presentation ........................................................................... 122
6.13
AT+CLIR
6.14
AT+COLP Connected line identification presentation .................................................................... 125
6.15
AT+VTS
DTMF and tone generation .............................................................................................. 127
6.16
AT+VTD
Tone duration .................................................................................................................. 128
6.17
AT+CSTA Select type of address .................................................................................................... 129
6.18
AT+CMOD
Call mode .................................................................................................................... 130
6.19
AT+VMUTE
Speaker mute control................................................................................................. 131
6.20
AT+CMUT
6.21
AT+MORING
Enable or disable report MO ring URC................................................................... 132
6.22
AT+CSDVC
Switch voice channel device ...................................................................................... 133
6.23
AT+CLVL Loudspeaker volume level ............................................................................................. 134
6.24
AT+SIDET
AL
6.1
FI
D
EN
TI
Select bearer service type .............................................................................................. 109
C
M
C
M
O
N
Calling line identification restriction .............................................................................. 124
O
6
5.11
Microphone mute control............................................................................................. 132
Set sidetone .................................................................................................................. 135
AT+CACDBFN
Change default ACDB filename ........................................................................... 136
6.26
AT+CPCMREG
USB audio control ................................................................................................ 137
6.27
AT+CMICGAIN
Adjust mic gain ................................................................................................... 138
6.28
AT+COUTGAIN
Adjust out gain ................................................................................................... 139
6.29
AT+CTXVOL Adjust TX voice mic volume .................................................................................. 139
6.30
AT+CTXMICGAIN
6.31
AT+CRXVOL Adjust RX voice output speaker volume................................................................. 141
6.32
AT+CECH
Inhibit far-end echo....................................................................................................... 142
6.33
AT+CECDT
Inhibit echo during doubletalk ................................................................................... 143
SI
6.25
Adjust TX voice mic gain .............................................................................. 140
SIM7500_SIM7600 Series_AT Command Manual_V1.07
10
2017-12-25
Smart Machine Smart Decision
AT+CECWB
Inhibit echo in the high band ..................................................................................... 144
6.35
AT+CNSN
MIC NOISE suppression .............................................................................................. 145
6.36
AT+CNSLIM
6.37
AT+CFNSMOD
6.38
AT+CFNSIN
6.39
AT+CFNSLVL Adjust parameter fnsTargetNS of RX_VOICE_FNS ............................................. 148
6.40
AT+CECRX
Enable or disable VOICE_MOD_ENABLE .............................................................. 149
6.41
AT+CNLPPG
Modify the NLPP_gain in DSP ................................................................................ 150
6.42
AT+CNLPPL Modify the NLPP_limit in DSP ................................................................................ 150
6.43
AT+CECM
6.44
AT+CPCMFRM
FI
L
E
Adjust parameter fnsInputGain of RX_VOICE_FNS ............................................... 147
Adjust echo canceller ................................................................................................... 151
Set usb audio sample rate to 16k bit .................................................................... 152
AL
Select message service.................................................................................................. 154
7.2
AT+CPMS
Preferred message storage ............................................................................................ 155
7.3
AT+CMGF
Select SMS message format ......................................................................................... 157
7.4
AT+CSCA SMS service centre address ........................................................................................... 158
7.5
AT+CSCB
7.6
AT+CSMP Set text mode parameters .............................................................................................. 160
7.7
AT+CSDH
7.8
AT+CNMA New message acknowledgement to ME/TA ................................................................ 162
7.9
AT+CNMI
New message indications to TE .................................................................................... 163
7.10
AT+CGSMS
Select service for MO SMS messages ....................................................................... 165
7.11
AT+CMGL List SMS messages from preferred store ..................................................................... 166
7.12
AT+CMGR
Read message .............................................................................................................. 170
7.13
AT+CMGS
Send message ............................................................................................................... 174
7.14
AT+CMSS
Send message from storage .......................................................................................... 175
7.15
AT+CMGW Write message to memory .......................................................................................... 176
7.16
AT+CMGD
Delete message ............................................................................................................ 178
7.17
AT+CMGMT
Change message status ............................................................................................. 179
7.18
AT+CMVP Set message valid period .............................................................................................. 180
7.19
AT+CMGRD
Read and delete message .......................................................................................... 181
7.20
AT+CMGSEX
Send message .......................................................................................................... 182
7.21
AT+CMSSEX
Send multi messages from storage .......................................................................... 183
7.22
AT+CMGP Set cdma/evdo text mode parameters ........................................................................... 184
EN
TI
AT+CSMS
Select cell broadcast message indication ...................................................................... 159
C
O
N
FI
D
Show text mode parameters .......................................................................................... 161
M
C
M
9
Adjust parameter fnsMode of RX_VOICE_FNS ................................................. 146
7.1
AT Commands for Phonebook ..................................................................................................... 186
8.1
AT+CPBS
Select phonebook memory storage ................................................................................ 186
8.2
AT+CPBR
Read phonebook entries ................................................................................................ 187
8.3
AT+CPBF
Find phonebook entries ................................................................................................. 189
8.4
AT+CPBW Write phonebook entry ................................................................................................. 190
8.5
AT+CNUM
SI
8
MIC NOISE suppression .......................................................................................... 145
AT Commands for SMS............................................................................................................... 154
O
7
6.34
Subscriber number....................................................................................................... 191
AT Commands for GPRS............................................................................................................. 193
9.1
AT+CGREG
GPRS network registration status .............................................................................. 193
9.2
AT+CGATT Packet domain attach or detach .................................................................................. 194
SIM7500_SIM7600 Series_AT Command Manual_V1.07
11
2017-12-25
Smart Machine Smart Decision
9.3
AT+CGACT
9.4
AT+CGDCONT
Define PDP context .............................................................................................. 196
9.5
AT+CGDSCONT
Define Secondary PDP Context ......................................................................... 198
9.6
AT+CGTFT Traffic Flow Template ................................................................................................ 201
9.7
AT+CGQREQ
9.8
AT+CGEQREQ
3G quality of service profile (requested) .............................................................. 206
9.9
AT+CGQMIN
Quality of service profile (minimum acceptable) .....................................................211
9.10
AT+CGEQMIN
3G quality of service profile (minimum acceptable) ............................................ 214
9.11
AT+CGDATA Enter data state......................................................................................................... 218
9.12
AT+CGPADDR
Show PDP address ................................................................................................ 219
9.13
AT+CGCLASS
GPRS mobile station class .................................................................................. 221
9.14
AT+CGEREP GPRS event reporting .............................................................................................. 222
9.15
AT+CGAUTH
AL
FI
L
E
Quality of service profile (requested) ..................................................................... 204
Set type of authentication for PDP-IP connections of GPRS .................................. 224
Hardware Related Commands ................................................................................................. 226
TI
10
PDP context activate or deactivate ............................................................................. 195
AT+CVALARM
Low and high voltage Alarm................................................................................ 226
10.2
AT+CVAUXS
Set state of the pin named VREG_AUX1 ............................................................... 227
10.3
AT+CVAUXV Set voltage value of the pin named VREG_AUX1 ................................................. 228
10.4
AT+CADC
Read ADC value ........................................................................................................... 229
10.5
AT+CADC2
Read ADC2 value ....................................................................................................... 229
10.6
AT+CMTE
Control the module whether power shutdown when the module’s temperature upon the
D
EN
10.1
FI
critical temperature ......................................................................................................................................... 230
AT+CPMVT
Low and high voltage Power Off ............................................................................... 232
10.8
AT+CDELTA Set the module go to recovery mode ........................................................................ 233
10.9
AT+CRIIC
Read values from register of IIC device ....................................................................... 233
10.10 AT+CWIIC
Write values to register of IIC device .......................................................................... 234
10.11 AT+CBC
Read the voltage value of the power supply .................................................................... 235
C
O
N
10.7
10.12 AT+CPMUTEMP Read the temperature of the module .................................................................. 235
11
AT Commands for SIM Application Toolkit ............................................................................ 237
AT+STIN
SAT Indication ................................................................................................................ 237
11.2
AT+STGI
Get SAT information ...................................................................................................... 238
11.3
AT+STGR
SAT respond .................................................................................................................. 241
11.4
AT+STK
STK switch ...................................................................................................................... 242
11.5
AT+STKFMT Set STK pdu format ................................................................................................. 243
11.6
AT+STENV Original STK PDU Envelope Command .................................................................... 244
M
C
O
M
11.1
11.7
SI
12
AT+STSM
Get STK Setup Menu List with PDU Mode ................................................................. 245
AT Commands for Hardware ................................................................................................... 246
12.1
AT+IPREX
Set local baud rate permanently ................................................................................... 246
12.2
AT+CFGRI
Indicate RI when using URC ....................................................................................... 247
12.3
AT+CSCLK Control UART Sleep ..................................................................................................... 248
12.4
AT+CMUX
12.5
AT+CGFUNC Enable/disable the function for the special GPIO ...................................................... 250
12.6
AT+CGDRT
12.7
AT+CGSETV Set the value of specified GPIO ............................................................................... 253
Enable the multiplexer over the UART ....................................................................... 249
Set the direction of specified GPIO............................................................................ 252
SIM7500_SIM7600 Series_AT Command Manual_V1.07
12
2017-12-25
Smart Machine Smart Decision
12.8
AT+CGGETV Get the value of specified GPIO.............................................................................. 253
12.9
AT+CGISR
13
Set GPIO interrupt trigger condition ........................................................................... 254
AT Commands for File System ................................................................................................ 256
AT+FSCD
Select directory as current directory .............................................................................. 256
13.2
AT+FSMKDIR
Make new directory in current directory ............................................................... 257
13.3
AT+FSRMDIR
Delete directory in current directory ...................................................................... 258
13.4
AT+FSLS
13.5
AT+FSDEL Delete file in current directory .................................................................................... 260
13.6
AT+FSRENAME
13.7
AT+FSATTRI
Request file attributes .............................................................................................. 262
13.8
AT+FSMEM
Check the size of available memory .......................................................................... 263
13.9
AT+FSLOCA Select storage place .................................................................................................. 263
E
13.1
FI
L
List directories/files in current directory ........................................................................ 259
AL
Rename file in current directory ........................................................................ 261
13.10 AT+FSCOPY Copy an appointed file ............................................................................................. 264
14.1
14.2
15
TI
AT Commands for File Transmission ...................................................................................... 267
AT+CFTRANRX
Transfer a file to EFS ......................................................................................... 267
AT+CFTRANTX
Transfer a file from EFS to host ......................................................................... 268
EN
14
AT Commands for Internet Service ......................................................................................... 270
15.1
PDP .................................................................................................................................................... 270
AT+CSOCKSETPN
15.1.2
AT+CIPDNSSET Set DNS query parameters .......................................................................................... 271
15.1.3
AT+CDNSGIP Query the IP address of given domain name ................................................................... 272
15.1.4
AT+CDNSGHNAME
15.1.5
AT+CPING Ping destination address....................................................................................................... 274
15.1.6
AT+CPINGSTOP Stop an ongoing ping session ..................................................................................... 276
15.1.7
AT+CTCPFIN Configure TCP FIN ......................................................................................................... 277
15.1.8
AT+CTCPKA Conigure TCP heartbeat ................................................................................................... 278
15.1.9
AT+CTEUTP Set unknown incoming TCP packet echo .......................................................................... 279
15.1.10
AT+CUPURE
15.1.11
AT+CINICMPALLOW Preferred ICMP filter ......................................................................................... 281
FI
N
O
C
AT+CDNSSRV
Get dns server ip address ............................................................................................... 282
TCP/UDP ........................................................................................................................................... 283
O
15.2
Query the domain name of given IP address ........................................................ 273
Set UDP port unreachable ICMP echo ............................................................................. 280
M
15.1.12
Set active PDP context’s profile number ................................................................ 270
D
15.1.1
AT+CIPCCFG Configure parameters of socket ....................................................................................... 283
15.2.2
AT+CIPSENDMODE
15.2.3
AT+CIPTIMEOUT Set TCP/IP timeout value............................................................................................ 286
M
C
15.2.1
Select sending mode ............................................................................................ 285
AT+CIPHEAD
15.2.5
AT+CIPSRIP Show Remote IP address and Port ..................................................................................... 288
15.2.6
AT+CIPMODE
15.2.7
AT+NETOPEN Open socket ................................................................................................................... 290
15.2.8
AT+NETCLOSE
15.2.9
AT+IPADDR
15.2.10
AT+CIPFILTERSET IP filter configuration ............................................................................................ 293
15.2.11
AT+SERVERSTART Startup TCP server ................................................................................................ 295
15.2.12
AT+SERVERSTOP Stop TCP server ....................................................................................................... 296
SI
15.2.4
Add an IP head when receiving data ............................................................................... 287
Select TCP/IP application mode .................................................................................... 289
Close socket................................................................................................................. 291
Inquire socket PDP address ............................................................................................... 292
SIM7500_SIM7600 Series_AT Command Manual_V1.07
13
2017-12-25
Smart Machine Smart Decision
15.2.13
AT+CIPOPEN Establish connection in multi-socket mode ..................................................................... 297
15.2.14
AT+CIPSEND Send data through TCP or UDP connection .................................................................... 299
15.2.15
AT+CIPRXGET Get the network data manually ..................................................................................... 302
15.2.16
AT+CIPCLOSE
15.2.17
AT+CIPSTAT Inquire the total size of data sent or received ................................................................... 306
15.2.18
Information elements related to TCP/IP ..................................................................................................... 307
15.2.19
Unsolicited TCP/IP command <err> Codes ................................................................................................ 307
E
FTP ..................................................................................................................................................... 308
FI
L
15.3
Close TCP or UDP socket ............................................................................................. 304
15.3.1
AT+CFTPPORT Set FTP server port ....................................................................................................... 308
15.3.2
AT+CFTPMODE
15.3.3
AT+CFTPTYPE Set FTP type ................................................................................................................. 309
15.3.4
AT+CFTPSERV Set FTP server domain name or IP address................................................................... 310
15.3.5
AT+CFTPUN Set user name for FTP access ............................................................................................311
15.3.6
AT+CFTPPW Set user password for FTP access ..................................................................................... 312
15.3.7
AT+CFTPGETFILE
Get a file from FTP server to EFS .......................................................................... 313
15.3.8
AT+CFTPPUTFILE
Upload a file from module EFS to FTP server ....................................................... 314
15.3.9
AT+CFTPGET Get a file from FTP server and output it to SIO .............................................................. 315
15.3.10
AT+CFTPPUT Upload the DATA from SIO to FTP server ..................................................................... 317
15.3.11
AT+CFTPLIST List the items in the directory on FTP server ................................................................. 319
15.3.12
AT+CFTPMKD Create a new directory on FTP server ........................................................................... 320
15.3.13
AT+CFTPRMD Delete a directory on FTP server ................................................................................... 321
15.3.14
AT+CFTPDELE
15.3.15
AT+CFTPCACHERD
15.3.16
Unsolicited FTP Codes (Summary of CME ERROR Codes) ..................................................................... 324
AL
TI
EN
D
FI
Delete a file on FTP server ........................................................................................... 322
N
Output cached data to MCU ................................................................................ 322
O
15.4
Set FTP mode ............................................................................................................. 309
FTPS................................................................................................................................................... 324
AT+CFTPSSTART Acquire FTPS protocol stack ................................................................................... 324
15.4.2
AT+CFTPSSTOP Stop FTPS protocol stack ........................................................................................... 325
15.4.3
AT+CFTPSLOGIN
15.4.4
AT+CFTPSLOGOUT Logout the FTPS server ....................................................................................... 327
AT+CFTPSMKD Create a new directory on FTPS server....................................................................... 327
AT+CFTPSRMD Delete a directory on FTPS server .............................................................................. 328
AT+CFTPSDELE
15.4.8
AT+CFTPSLIST List the items in the directory on FTPS server ............................................................. 329
15.4.9
AT+CFTPSGETFILE
Get a file from FTPS server to EFS ..................................................................... 331
15.4.10
AT+CFTPSPUTFILE
Upload a file in module EFS to FTPS server ....................................................... 332
15.4.11
AT+CFTPSGET Get a file from FTPS server to serial port..................................................................... 334
15.4.12
AT+CFTPSPUT Put a file to FTPS server ............................................................................................... 336
15.4.13
AT+CFTPSSINGLEIP Set FTPS data socket address type...................................................................... 337
15.4.14
AT+CFTPSCACHERD
15.4.15
Unsolicited FTPS Codes ............................................................................................................................. 339
15.4.16
Unsolicited FTPS command <err> Codes .................................................................................................. 339
SI
M
15.4.7
C
O
15.4.6
Login the FTPS server ............................................................................................. 326
M
15.4.5
C
15.4.1
15.5
Delete a file on FTPS server ...................................................................................... 329
Output cached data to MCU .............................................................................. 338
HTTP .................................................................................................................................................. 339
15.5.1
AT+CHTTPACT
Launch a HTTP operation .......................................................................................... 339
SIM7500_SIM7600 Series_AT Command Manual_V1.07
14
2017-12-25
Smart Machine Smart Decision
15.5.2
15.6
Unsolicited HTTP codes (summary of CME ERROR codes)..................................................................... 342
HTTPS ............................................................................................................................................... 343
AT+CHTTPSSTART Acquire HTTPS protocol stack ............................................................................. 343
15.6.2
AT+CHTTPSSTOP Stop HTTPS protocol stack ..................................................................................... 343
15.6.3
AT+CHTTPSOPSE
Open HTTPS session .............................................................................................. 344
15.6.4
AT+CHTTPSCLSE
Close HTTPS session .............................................................................................. 345
15.6.5
AT+CHTTPSSEND Send HTTPS request .............................................................................................. 345
15.6.6
AT+CHTTPSRECV Receive HTTPS response ....................................................................................... 347
15.6.7
AT+CHTTPSSTATE
15.6.8
Unsolicited HTTPS Codes.......................................................................................................................... 349
15.6.9
Unsolicited HTTPS command <err> Codes ............................................................................................... 349
FI
L
Get the state of HTTPS stack ................................................................................ 348
HTP .................................................................................................................................................... 350
AL
15.7
E
15.6.1
15.7.1
AT+CHTPSERV Set HTP server info ...................................................................................................... 350
15.7.2
AT+CHTPUPDATE
15.7.3
Unsolicited HTP Codes .............................................................................................................................. 352
TI
NTP .................................................................................................................................................... 352
EN
15.8
Updating date time using HTP protocol ................................................................. 351
15.8.1
AT+CNTP update system time ................................................................................................................ 352
15.8.2
Unsolicited NTP Codes .............................................................................................................................. 353
Common Channel Service .................................................................................................................. 353
D
15.9
AT+CCHSTART Acquire common channel service ................................................................................ 354
15.9.2
AT+CCHSTOP Stop common channel service ........................................................................................ 354
15.9.3
AT+CCHOPEN
Open a channel .............................................................................................................. 355
15.9.4
AT+CCHCLOSE
Close a channel ........................................................................................................... 356
15.9.5
AT+CCHSEND
Send data to peer ........................................................................................................... 357
15.9.6
AT+CCHRECV
Receive data from the channel ...................................................................................... 358
15.9.7
AT+CCHSET Set the parameter of common channel service.................................................................. 359
15.9.8
AT+CCHADDR
15.9.9
AT+CCERTVERIFY Set SSL server cert verify flag .............................................................................. 361
15.9.10
Unsolicited common channel Codes ........................................................................................................... 362
N
O
C
Get the IPv4 address for common channel service ....................................................... 360
M
15.9.11
FI
15.9.1
Unsolicited common channel command <err> Codes ................................................................................ 362
15.10.1
AT+CCERTDOWN
Transfer a certificate file to Module ........................................................................ 363
15.10.2
AT+CCERTLIST List certificate/key in module ..................................................................................... 363
15.10.3
AT+CCERTDELE
Delete certificate/key in the module .......................................................................... 364
M
C
O
15.10 SSL Certificate & Key Management .................................................................................................. 363
16
AT Commands for Open/Close Network ................................................................................. 366
AT+CNETSTART
16.2
AT+CNETSTOP Close network ...................................................................................................... 367
16.3
AT+CNETIPADDR
16.4
Unsolicited CNETSTART/CNETSTOP Codes .................................................................................. 368
SI
16.1
17
Open network .................................................................................................... 366
Inquire PDP address ....................................................................................... 368
AT Commands for GPS ........................................................................................................... 370
17.1
AT+CGPS
Start/Stop GPS session .................................................................................................. 370
17.2
AT+CGPSINFO
Get GPS fixed position information ..................................................................... 371
17.3
AT+CGPSCOLD
Cold start GPS .................................................................................................... 373
SIM7500_SIM7600 Series_AT Command Manual_V1.07
15
2017-12-25
Smart Machine Smart Decision
17.4
AT+CGPSHOT
Hot start GPS ........................................................................................................ 373
17.5
AT+CGPSURL Set AGPS default server URL ............................................................................... 374
17.6
AT+CGPSSSL Set AGPS transport security ................................................................................... 375
17.7
AT+CGPSAUTO
17.8
AT+CGPSNMEA Configure NMEA sentence type ........................................................................ 376
17.9
AT+CGPSNEMARATE
Start GPS automatic ........................................................................................... 375
E
Set NMEA output rate ........................................................................... 377
Configure AGPS MO method ................................................................................. 378
17.11 AT+CGPSFTM
Start GPS test mode .............................................................................................. 379
FI
L
17.10 AT+CGPSMD
17.12 AT+CGPSDEL Delete the GPS information ................................................................................... 380
17.13 AT+ CGPSXE
Enable/Disable GPS XTRA function ...................................................................... 381
17.14 AT+CGPSXD
Download XTRA assistant file ................................................................................ 381
Download XTRA assistant file automatically............................................... 382
17.16 AT+CGPSINFOCFG
Report GPS NMEA-0183 sentence .............................................................. 383
AL
17.15 AT+CGPSXDAUTO
Configure positioning mode ................................................................................. 385
17.18 AT+CGPSMSB
Configure based mode switch to standalone ......................................................... 386
17.19 AT+CGPSHOR
Configure positioning desired accuracy ................................................................ 387
EN
TI
17.17 AT+CGPSPMD
17.20 AT+CGPSNOTIFY LCS respond positioning request .................................................................... 388
17.21 AT+CGPSMODE
Enable/Disable BEIDOU session.................................................................................. 389
17.23 AT+CGNSSINFO
D
17.22 AT+CBDS
Configure GPS and GLONASS mode ............................................................... 388
Get GNSS fixed position information ............................................................... 390
Base station location...................................................................................................... 392
Base station location configure .............................................................................. 395
17.27 AT+CASSISTLOC
18
N
17.26 AT+CLBSCFG
Base station location of LTE/CDMA1x mode ................................................. 397
O
17.25 AT+CLBS
FI
17.24 Unsolicited XTRA download Codes .................................................................................................. 392
Audio Application Commands ................................................................................................. 399
AT+CREC
18.2
AT+CCMXPLAYWAV
Play wav audio file .................................................................................. 400
18.3
AT+CCMXSTOPWAV
Stop playing wav audio file ..................................................................... 401
18.4
AT+ CCMXPLAY Play audio file ................................................................................................... 401
18.5
AT+ CCMXSTOP Stop playing audio file ...................................................................................... 402
M
Appendixes .............................................................................................................................. 403
O
19
record wav audio file .................................................................................................. 399
C
18.1
Verbose code and numeric code ......................................................................................................... 403
19.2
Response string of AT+CEER ............................................................................................................ 403
19.3
Summary of CME ERROR codes ...................................................................................................... 407
M
C
19.1
Summary of CMS ERROR codes ...................................................................................................... 410
SI
19.4
SIM7500_SIM7600 Series_AT Command Manual_V1.07
16
2017-12-25
1
E
Scope
AL
The present document describes the AT Command Set for the SIMCom Module:
SIM7500 series, SIM7600 series.
FI
L
1.1
Introduction
TI
More information about the SIMCom Module which includes the Software Version information can be
retrieved by the command ATI. In this document, a short description, the syntax, the possible setting values
and responses, and some examples of AT commands are presented.
EN
Prior to using the Module, please read this document and the Version History to know the difference from
the previous document.
References
O
1.2
N
FI
D
In order to implement communication successfully between Customer Application and the Module, it is
recommended to use the AT commands in this document, but not to use some commands which are not
included in this document.
C
The present document is based on the following standards:
M
C
O
M
[1] ETSI GSM 01.04: Abbreviations and acronyms.
[2] 3GPP TS 27.005: Use of Data Terminal Equipment – Data Circuit terminating Equipment (DTE –
DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS).
[3] 3GPP TS 27.007: AT command set for User Equipment (UE).
[4] WAP-224-WTP-20010710-a
[5] WAP-230-WSP-20010705-a
[6] WAP-209-MMSEncapsulation-20010601-a
Terms and abbreviations
SI
1.3
For the purposes of the present document, the following abbreviations apply:
AT
ATtention; the two-character abbreviation is used to start a command line to be sent
from TE/DTE to TA/DCE
DCE
Data Communication Equipment; Data Circuit terminating Equipment
DCS
Digital Cellular Network
DTE
Data Terminal Equipment
FI
L
AL
C
O
N
FI
D
EN
TI
Dual Tone Multi–Frequency
Enhanced Data GSM Environment
Enhanced General Packet Radio Service
General–Purpose Input/Output
General Packet Radio Service
Global System for Mobile communications
High Speed Downlink Packet Access
High Speed Uplink Packet Access
Inter–Integrated Circuit
International Mobile station Equipment Identity
International Mobile Subscriber Identity
Mobile Equipment
Mobile–Originated
Mobile Station
Mobile–Terminated; Mobile Termination
Personal Communication System
Protocol Data Unit
Personal Identification Number
Personal Unlock Key
Subscriber Identity Module
Short Message Service
Short Message Service – Service Center
Terminal Adaptor; e.g. a data card (equal to DCE)
Terminal Equipment; e.g. a computer (equal to DTE)
User Equipment
Universal Mobile Telecommunications System
Universal Subscriber Identity Module
Wideband Code Division Multiple Access
File Transfer Protocol
Hyper Text Transfer Protocol
Real Time Clock
Unsolicited Result Code
Definitions and conventions
M
1.4
C
O
M
DTMF
EDGE
EGPRS
GPIO
GPRS
GSM
HSDPA
HSUPA
I2C
IMEI
IMSI
ME
MO
MS
MT
PCS
PDU
PIN
PUK
SIM
SMS
SMS–SC
TA
TE
UE
UMTS
USIM
WCDMA
FTP
HTTP
RTC
URC
E
Smart Machine Smart Decision
SI
1. For the purposes of the present document, the following syntactical definitions apply:
<CR>
Carriage return character.
<LF>
Linefeed character.
<…>
Name enclosed in angle brackets is a syntactical element. Brackets themselves do not
appear in the command line.
[…]
Optional subparameter of AT command or an optional part of TA information response
is enclosed in square brackets. Brackets themselves do not appear in the command line.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
18
2017-12-25
Smart Machine Smart Decision
If subparameter is not given, its value equals to its previous value or the recommended
default value.
Underlined defined subparameter value is the recommended default setting or factory
setting.
underline
2. Document conventions:
FI
L
E
♦ Display the examples of AT commands with Italic format.
♦ Not display blank-line between command line and responses or inside the responses.
♦ Generally, the characters <CR> and <LF> are intentionally omitted throughout this document.
♦ If command response is ERROR, not list the ERROR response inside command syntax.
AL
NOTE: AT commands and responses in figures may be not following above conventions.
3. Special marks for commands or parameters:
–
Is the command PIN protected?
YES –
TI
SIM PIN
AT command can be used only when SIM PIN is READY.
– AT command can be used when SIM card is absent or SIM PIN validation is
pending.
References – Where is the derivation of command?
EN
NO
– 3GPP Technical Specification 127 007.
V.25ter
– ITU–T Recommendation V.25ter.
Vendor
– This command is supported by SIMCom.
SI
M
C
O
M
C
O
N
FI
D
3GPP TS 27.007
SIM7500_SIM7600 Series_AT Command Manual_V1.07
19
2017-12-25
Smart Machine Smart Decision
2
E
Interface settings
FI
L
2.1
AT Interface Synopsis
Between Customer Application and the Module, standardized RS–232 interface is used for the
communication, and default values for the interface settings as following:
AT command syntax
TI
2.2
AL
115200bps, 8 bit data, no parity, 1 bit stop, no data stream control.
EN
The prefix “AT” or “at” (no case sensitive) must be included at the beginning of each command line
(except A/ and +++), and the character <CR> is used to finish a command line so as to issue the command
line to the Module. It is recommended that a command line only includes a command.
N
FI
D
When Customer Application issues a series of AT commands on separate command lines, leave a pause
between the preceding and the following command until information responses or result codes are retrieved
by Customer Application, for example, “OK” is appeared. This advice avoids too many AT commands are
issued at a time without waiting for a response for each command.
C
1. Basic Command
O
In the present document, AT commands are divided into three categories: Basic Command, S Parameter
Command, and Extended Command.
O
M
The format of Basic Command is “AT<x><n>” or “AT&<x><n>”, “<x>” is the command name, and “<n>”
is/are the parameter(s) for the basic command, and optional. An example of Basic Command is “ATE<n>”,
which informs the TA/DCE whether received characters should be echoed back to the TE/DTE according to
the value of “<n>”; “<n>” is optional and a default value will be used if omitted.
C
2. S Parameter Command
SI
M
The format of S Parameter Command is “ATS<n>=<m>”, “<n>” is the index of the S–register to set, and
“<m>” is the value to assign to it. “<m>” is optional; in this case, the format is “ATS<n>”, and then a
default value is assigned.
3. Extended Command
The Extended Command has several formats, as following table list:
SIM7500_SIM7600 Series_AT Command Manual_V1.07
20
2017-12-25
Smart Machine Smart Decision
Table 2-1: Types of Extended Command
Syntax
Comments
Test Command
AT+<NAME>=?
Test the existence of the command; give some
information about the command subparameters.
Read Command
AT+<NAME>?
Check the current values of subparameters.
Write Command
AT+<NAME>=<…>
Set user-definable subparameter values.
Execution Command
AT+<NAME>
Read non-variable subparameters determined by
internal processes.
FI
L
E
Command Type
Information responses
TI
2.3
AL
NOTE: The character “+” between the prefix “AT” and command name may be replaced by other
character. For example, using “#” or “$”instead of “+”.
EN
If the commands included in the command line are supported by the Module and the subparameters are
correct if presented, some information responses will be retrieved by from the Module. Otherwise, the
Module will report “ERROR” or “+CME ERROR” or “+CMS ERROR” to Customer Application.
SI
M
C
O
M
C
O
N
FI
D
Information responses start and end with <CR><LF>, i.e. the format of information responses is
“<CR><LF><response><CR><LF>”. Inside information responses, there may be one or more <CR><LF>.
Throughout this document, only the responses are presented, and <CR><LF> are intentionally omitted.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
21
2017-12-25
Smart Machine Smart Decision
A/
Repeat last command
E
3.1
AT Commands According V.25TER
FI
L
3
Description
V.25ter
EN
NO
References
TI
SIM PIN
AL
This command is used for implement previous AT command repeatedly (except A/), and the return
value depends on the last AT command. If A/ is issued to the Module firstly after power on, the
response “OK” is only returned.
Syntax
Responses
The response the last AT command return
Examples
M
C
O
AT+GCAP
+GCAP:+CGSM,+FCLASS,+DS
OK
A/
+GCAP:+CGSM,+FCLASS,+DS
OK
N
FI
D
Execution Command
A/
Dial command
C
O
3.2 ATD
Description
SI
M
This command is used to list characters that may be used in a dialling string for making a call or
controlling supplementary services.
NOTE:
1. Support several “P” or “p” in the DTMF string but the valid auto-sending DTMF after characters
“P” or “p” should not be more than 29.
2. Auto-sending DTMF after character “P” or “p” should be ASCII character in the set 0-9, *, #.
SIM PIN
NO
References
V25.ter
SIM7500_SIM7600 Series_AT Command Manual_V1.07
22
2017-12-25
Smart Machine Smart Decision
Syntax
Responses
Originate a voice call successfully:
OK
VOICE CALL: BEGIN
E
Execution Commands
ATD<n>[<mgsm>][;]
FI
L
Originate a data call successfully:
CONNECT [<text>]
Originate a call unsuccessfully during command execution:
ERROR
AL
Originate a call unsuccessfully for failed connection recovery:
NO CARRIER
EN
TI
Originate a call unsuccessfully for error related to the MT:
+CME ERROR: <err>
Defined values
SI
M
C
O
M
C
O
N
FI
D
<n>
String of dialing digits and optionally V.25ter modifiers dialing digits:
0 1 2 3 4 5 6 7 8 9 * # + A B C
Following V.25ter modifiers are ignored:
, T P ! W @
<mgsm>
String of GSM modifiers:
I
Activates CLIR (disables presentation of own phone number to called party)
i
Deactivates CLIR (enables presentation of own phone number to called party)
G
Activate Closed User Group explicit invocation for this call only
g
Deactivate Closed User Group explicit invocation for this call only
<;>
The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax
calls.
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
Service failure result code string; the string formats please refer +CME ERROR result code and
AT+CMEE command.
Examples
ATD10086;
OK
VOICE CALL:BEGIN
SIM7500_SIM7600 Series_AT Command Manual_V1.07
23
2017-12-25
Smart Machine Smart Decision
3.3
ATD><mem><n> Originate call from specified memory
Description
This command is used to originate a call using specified memory and index number.
V.25ter
FI
L
NO
References
E
SIM PIN
Responses
Originate a voice call successfully:
OK
VOICE CALL: BEGIN
TI
Execution Commands
ATD><mem><n>[;]
AL
Syntax
EN
Originate a data call successfully:
CONNECT [<text>]
D
Originate a call unsuccessfully during command execution:
ERROR
FI
Originate a call unsuccessfully for failed connection recovery:
NO CARRIER
C
Defined values
O
N
Originate a call unsuccessfully for error related to the MT:
+CME ERROR: <err>
SI
M
C
O
M
<mem>
Phonebook storage: (For detailed description of storages see AT+CPBS)
"DC"
ME dialed calls list
"MC"
ME missed (unanswered received) calls list
"RC"
ME received calls list
"SM"
SIM phonebook
"ME"
UE phonebook
"FD"
SIM fixed dialing phonebook
"ON"
MSISDN list
"LD"
Last number dialed phonebook
"EN"
Emergency numbers
<n>
Integer type memory location in the range of locations available in the selected memory, i.e. the
index returned by AT+CPBR.
<;>
The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax
calls.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
24
2017-12-25
Smart Machine Smart Decision
E
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
Service failure result code string; the string formats please refer +CME ERROR result code and
AT+CMEE command.
FI
L
Examples
ATD><n> Originate call from active memory (1)
Description
SIM PIN
References
V.25ter
D
NO
EN
This command is used to originate a call to specified number.
TI
3.4
AL
ATD>SM3;
OK
VOICE CALL: BEGIN
FI
Syntax
Responses
Originate a voice call successfully:
OK
VOICE CALL: BEGIN
C
O
N
Execution Commands
ATD><n>[;]
Originate a call unsuccessfully during command execution:
ERROR
Originate a call unsuccessfully for failed connection recovery:
NO CARRIER
Originate a call unsuccessfully for error related to the MT:
+CME ERROR: <err>
SI
M
C
O
M
Originate a data call successfully:
CONNECT [<text>]
Defined values
<n>
Integer type memory location in the range of locations available in the selected memory, i.e. the
index number returned by AT+CPBR.
<;>
The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
25
2017-12-25
Smart Machine Smart Decision
E
calls.
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
Service failure result code string; the string formats please refer +CME ERROR result code and
AT+CMEE command.
FI
L
Examples
ATD><str> Originate call from active memory (2)
TI
3.5
AL
ATD>2;
OK
VOICE CALL: BEGIN
EN
Description
This command is used to originate a call to specified number.
V.25ter
FI
NO
References
D
SIM PIN
N
Syntax
Responses
Originate a voice call successfully:
OK
VOICE CALL: BEGIN
SI
M
C
O
M
C
O
Execution Commands
ATD><str>[;]
Originate a data call successfully:
CONNECT [<text>]
Originate a call unsuccessfully during command execution:
ERROR
Originate a call unsuccessfully for failed connection recovery:
NO CARRIER
Originate a call unsuccessfully for error related to the MT:
+CME ERROR: <err>
Defined values
<str>
String type value, which should equal to an alphanumeric field in at least one phone book entry in
the searched memories. <str> formatted as current TE character set specified by AT+CSCS.<str>
must be double quoted.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
26
2017-12-25
Smart Machine Smart Decision
FI
L
E
<;>
The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax
calls.
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
Service failure result code string; the string formats please refer +CME ERROR result code and
AT+CMEE command.
Examples
TI
ATA Call answer
EN
3.6
AL
ATD>”Kobe”;
OK
VOICE CALL: BEGIN
Description
SIM PIN
References
V.25ter
N
YES
FI
D
This command is used to make remote station to go off-hook, e.g. answer an incoming call. If there
is no an incoming call and entering this command to TA, it will be return “NO CARRIER” to TA.
Responses
For voice call:
OK
VOICE CALL: BEGIN
C
M
C
O
M
Execution Commands
ATA
O
Syntax
For data call, and TA switches to data mode:
CONNECT
No connection or no incoming call:
NO CARRIER
SI
Examples
ATA
VOICE CALL: BEGIN
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
27
2017-12-25
Smart Machine Smart Decision
3.7
ATH Disconnect existing call
Description
SIM PIN
References
V.25ter
AL
NO
FI
L
E
This command is used to disconnect existing call. Before using ATH command to hang up a voice
call, it must set AT+CVHU=0. Otherwise, ATH command will be ignored and “OK” response is
given only.
This command is also used to disconnect PS data call, and in this case it doesn’t depend on the
value of AT+CVHU.
Responses
If AT+CVHU=0:
VOICE CALL: END: <time>
OK
EN
Execution Command
ATH
TI
Syntax
FI
D
OK
N
Defined values
C
O
<time>
Voice call connection time:
Format – HHMMSS (HH: hour, MM: minute, SS: second)
Examples
ATS0
Automatic answer incoming call
SI
M
3.8
C
O
M
AT+CVHU=0
OK
ATH
VOICE CALL:END:000017
OK
Description
The S-parameter command controls the automatic answering feature of the Module. If set to 000,
automatic answering is disabled, otherwise it causes the Module to answer when the incoming call
indication (RING) has occurred the number of times indicated by the specified value; and the
setting will not be stored upon power-off, i.e. the default value will be restored after restart.
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
28
2017-12-25
Smart Machine Smart Decision
YES
V.25ter
Syntax
E
Responses
<n>
OK
FI
L
Read Command
ATS0?
ERROR
Write Command
ATS0=<n>
Responses
OK
AL
ERROR
TI
Defined values
EN
<n>
FI
D
000
Automatic answering mode is disable. (default value when power-on)
001–255 Enable automatic answering on the ring number specified.
NOTE: 1.The S-parameter command is effective on voice call and data call.
2.If <n> is set too high, the remote party may hang up before the call can be answered
automatically.
N
Examples
C
M
+++ Switch from data mode to command mode
O
3.9
O
ATS0?
000
OK
ATS0=003
OK
C
Description
SI
M
This command is only available during a connecting PS data call. The +++ character sequence
causes the TA to cancel the data flow over the AT interface and switch to Command Mode. This
allows to enter AT commands while maintaining the data connection to the remote device.
NOTE: To prevent the +++ escape sequence from being misinterpreted as data, it must be preceded
and followed by a pause of at least 1000 milliseconds, and the interval between two ‘+’ character
can’t exceed 900 milliseconds.
SIM PIN
YES
References
V.25ter
SIM7500_SIM7600 Series_AT Command Manual_V1.07
29
2017-12-25
Smart Machine Smart Decision
Syntax
Execution Command
+++
Responses
OK
+++
OK
ATO
Switch from command mode to data mode
AL
3.10
FI
L
E
Examples
Description
SIM PIN
EN
TI
ATO is the corresponding command to the +++ escape sequence. When there is a PS data call
connected and the TA is in Command Mode, ATO causes the TA to resume the data and takes back
to Data Mode.
References
V.25ter
D
YES
FI
Syntax
Responses
TA/DCE switches to Data Mode from Command Mode:
CONNECT [<baud rate>]
O
N
Execution Command
ATO
C
If connection is not successfully resumed:
NO CARRIER
O
Examples
M
ERROR
M
C
ATO
CONNECT 115200
ATI
SI
3.11
Display product identification information
Description
This command is used to request the product information, which consists of manufacturer
identification, model identification, revision identification, International Mobile station Equipment
Identity (IMEI) and overall capabilities of the product.
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
30
2017-12-25
Smart Machine Smart Decision
NO
V.25ter
Syntax
FI
L
E
Responses
Manufacturer: <manufacturer>
Model: <model>
Revision: <revision>
IMEI: <sn>
+GCAP: list of <name>s
AL
Execution Command
ATI
OK
TI
Defined values
C
O
M
C
O
N
FI
D
EN
<manufacturer>
The identification of manufacturer.
<model>
The identification of model.
<revision>
The revision identification of firmware.
<sn>
Serial number identification, which consists of a single line containing IMEI (International Mobile
station Equipment Identity) number.
<name>
List of additional capabilities:
+CGSM
GSM function is supported
+FCLASS
FAX function is supported
+DS
Data compression is supported
+ES
Synchronous data mode is supported.
+CIS707-A CDMA data service command set
+CIS-856
EVDO data service command set
+MS
Mobile Specific command set
M
Examples
SI
ATI
Manufacturer: SIMCOM INCORPORATED
Model: SIMCOM_SIM7600C
Revision: SIM7600C _V1.0
IMEI: 351602000330570
+GCAP: +CGSM,+FCLASS,+DS
SIM7500_SIM7600 Series_AT Command Manual_V1.07
31
2017-12-25
Smart Machine Smart Decision
OK
3.12
AT+IPR Set local baud rate temporarily
Description
SIM PIN
References
V.25ter
AL
NO
FI
L
E
This command sets the baud rate of module’s serial interface temporarily, after reboot the baud rate
is set to value of IPREX.if set to 0,then support autobaud at now,and the value of the IPR will be
changed to current baudrate when the autobaud is successful.
TI
Syntax
Responses
+IPR: (list of supported<speed>s)
EN
Test Command
AT+IPR=?
Responses
+IPR: <speed>
OK
FI
Read Command
AT+IPR?
D
OK
Responses
OK
Execution Command
AT+IPR
ERROR
Responses
Set default value 115200:
OK
C
O
N
Write Command
AT+IPR=<speed>
M
Defined values
M
C
O
<speed>
Baud rate per second:
0, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800,921600,
3000000,3200000,3686400
SI
Examples
AT+IPR?
+IPR: 115200
OK
AT+IPR=?
+IPR:(0,300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400,460800,921600,
3000000,3200000,3686400)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
32
2017-12-25
Smart Machine Smart Decision
AT+IPR=115200
OK
AT+IPR=0
OK
E
AT+ICF Set control character framing
FI
L
3.13
Description
This command sets character framing which contains data bit, stop bit and parity bit.
NO
References
AL
SIM PIN
Vendor
TI
Syntax
Responses
+ICF: (list of supported<format>s), (list of supported<parity>s)
EN
Test Command
AT+ICF=?
OK
Responses
+ICF: <format>,<parity>
OK
Responses
OK
ERROR
Responses
Set default value:
OK
C
Execution Command
O
N
Write Command
AT+ICF=
<format>[,<parity>]
FI
D
Read Command
AT+ICF?
M
AT+ICF
O
Defined values
SI
M
C
<format>
1 –
2 –
3 –
4 –
5 –
6 –
<parity>
0 –
1 –
2 –
3 –
data bit 8, stop bit 2
data bit 8, parity bit 1,stop bit 1
data bit 8, stop bit 1
data bit 7, stop bit 2
data bit 7, parity bit 1,stop bit 1
data bit 7, stop bit 1
Odd
Even
mark
none
SIM7500_SIM7600 Series_AT Command Manual_V1.07
33
2017-12-25
Smart Machine Smart Decision
Examples
FI
L
Description
SIM PIN
References
V.25ter
D
NO
EN
The command sets the flow control mode of the module.
AL
AT+IFC Set local data flow control
TI
3.14
E
AT+ICF?
+ICF: 3,3
OK
AT+ICF=?
+ICF: (1-6),(0-3)
OK
AT+ICF=3,3
OK
FI
Syntax
Responses
+IFC: (list of supported<DCE>s), (list of supported<DTE>s)
N
Test Command
AT+IFC=?
O
OK
Read Command
AT+IFC?
C
ERROR
Responses
+IFC: <DCE>,<DTE>
M
OK
C
O
Write Command
AT+IFC=<DCE>[,<DTE>]
SI
M
Execution Command
AT+IFC
ERROR
Responses
OK
ERROR
Responses
Set default value:
OK
ERROR
Defined values
<DCE>
0 – none (default)
2 – RTS hardware flow control
SIM7500_SIM7600 Series_AT Command Manual_V1.07
34
2017-12-25
Smart Machine Smart Decision
<DTE>
0 – none (default)
2 – CTS hardware flow control
E
Examples
AT&C
AL
TI
Set DCD function mode
D
Description
EN
3.15
FI
L
AT+IFC?
+IFC: 0,0
OK
AT+IFC=?
+IFC: (0,2),(0,2)
OK
AT+IFC=2,2
OK
V.25ter
Syntax
Responses
OK
ERROR
O
M
Execution Command
AT&C[<value>]
C
O
NO
References
N
SIM PIN
FI
This command determines how the state of DCD PIN relates to the detection of received line signal
from the distant end.
C
Defined values
SI
M
<value>
0 DCD line shall always be on.
1 DCD line shall be on only when data carrier signal is present.
2 Setting winks(briefly transitions off,then back on)the DCD line when data calls end.
Examples
AT&C1
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
35
2017-12-25
Smart Machine Smart Decision
3.16
ATE Enable command echo
Description
This command sets whether or not the TA echoes characters.
V.25ter
FI
L
NO
References
E
SIM PIN
Syntax
Responses
OK
AL
Execution Command
ATE[<value>]
TI
ERROR
Echo mode off
Echo mode on
D
<value>
0 –
1 –
EN
Defined values
FI
Examples
O
AT&V Display current configuration
C
3.17
N
ATE1
OK
Description
M
This command returns some of the base configuration parameters settings.
References
O
SIM PIN
V.25ter
C
YES
M
Syntax
SI
Execution Command
AT&V
Responses
<TEXT>
OK
ERROR
Defined values
<TEXT>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
36
2017-12-25
Smart Machine Smart Decision
All relative configuration information.
……
AT&D
Set DTR function mode
TI
3.18
AL
OK
FI
L
AT&V
&C: 0; &D: 2; &F: 0; E: 1; L: 0; M: 0; Q: 0; V: 1; X: 0; Z: 0; S0: 0;
S3: 13; S4: 10; S5: 8; S6: 2; S7: 50; S8: 2; S9: 6; S10: 14; S11: 95;
+FCLASS: 0; +ICF: 3,3; +IFC: 2,2; +IPR: 115200; +DR: 0; +DS: 0,0,2048,6;
+WS46: 12; +CBST: 0,0,1;
E
Examples
Description
SIM PIN
References
D
V.25ter
FI
NO
EN
This command determines how the TA responds when DTR PIN is changed from the ON t
o the OFF condition during data mode.
N
Syntax
Responses
OK
O
Execution Command
AT&D[<value>]
Defined values
C
ERROR
M
C
O
M
<value>
0 TA ignores status on DTR.
1 ON->OFF on DTR: Change to Command mode with remaining the connected call
2 ON->OFF on DTR: Disconnect call, change to Command mode.During state DTR =
OFF is auto-answer off.
SI
Examples
AT&D1
OK
3.19
AT&S
Set DSR function mode
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
37
2017-12-25
Smart Machine Smart Decision
The command determines how the state of DSR pin works.
SIM PIN
YES
References
V.25ter
Responses
OK
FI
L
Execution Command
AT&S<value>
E
Syntax
ERROR
AL
Defined values
EN
TI
<value>
0 DSR line shall always be on.
1 DSR line shall be on only when DTE and DCE are connected.
Examples
FI
ATV Set result code format mode
N
3.20
D
AT&S0
OK
O
Description
C
This parameter setting determines the contents of the header and trailer transmitted with result
codes and information responses.
NOTE: In case of using This command without parameter <value> will be set to 0.
V.25ter
O
No
References
M
SIM PIN
C
Syntax
SI
M
Write Command
ATV[<value>]
Responses
If <value> =0
0
If <value> =1
OK
Defined values
<value>
0 Information response: <text><CR><LF>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
38
2017-12-25
Smart Machine Smart Decision
Short result code format: <numeric code><CR>
1 Information response: <CR><LF><text><CR><LF>
Long result code format: <CR><LF><verbose code><CR><LF>
Examples
FI
L
AT&F Set all current parameters to manufacturer defaults
AL
3.21
E
ATV1
OK
Description
SIM PIN
References
D
V.250
FI
NO
EN
TI
This command is used to set all current parameters to the manufacturer defined profile.
NOTE:List of parameters reset to manufacturer default can be found in defined values, factory
default settings restorable with AT&F[<value>].
Every ongoing or incoming call will be terminated.
N
Syntax
C
Defined values
Responses
OK
O
Execution Command
AT&F[<value>]
<value>
M
0 — Set some temporary TA parameters to manufacturer defaults. The setting after power on or reset is
same as value 0.
VALUE
AT+CATR
0
AT+CNMP
2
AT+CNAOP ①
7,9,4,2,5,3,11
AT+CTZU
0
AT+CVAUXV
2850
SI
M
C
O
default values
TA parameters
① The default value of no CDMA/EVDO version is 7,9,5,3,11,2,4
Examples
AT&F
SIM7500_SIM7600 Series_AT Command Manual_V1.07
39
2017-12-25
Smart Machine Smart Decision
OK
3.22
ATQ Set Result Code Presentation Mode
Description
SIM PIN
References
3GPP TS 27.005
AL
YES
FI
L
E
Specify whether the TA transmits any result code to the TE or not. Text information transmitted in
response is not affected by this setting
Syntax
TI
Responses
If <n>=0:
OK
If <n>=1:
No Responses
Responses
Set default value:0
OK
FI
D
Execution Command
ATQ
EN
Write Command
ATQ<n>
O
N
No Responses
C
Defined values
O
Examples
M
<n>
0 – DCE transmits result code
1 – DCE not transmits result code
M
C
ATQ0
OK
ATX Set CONNECT Result Code Format
SI
3.23
Description
This parameter setting determines whether the TA transmits unsolicited result codes or not. The
unsolicited result codes are
<CONNECT><SPEED><COMMUNICATION PROTOCOL>[<TEXT>]
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
40
2017-12-25
Smart Machine Smart Decision
YES
3GPP TS 27.005
Syntax
Responses
OK
E
Write Command
ATX<VALUE>
Execution Command
ATX
FI
L
ERROR
Responses
Set default value:1
OK
AL
ERROR
TI
Defined values
D
EN
<value>
0 – CONNECT result code returned
1,2,3,4 – May be transmits extern result codes according to AT&E and AT\V settings. Refer to
AT&E.
FI
Examples
O
AT\V Set CONNECT Result Code Format About Protocol
C
3.24
N
ATX1
OK
Description
M
This parameter setting determines whether report the communication protocol. If PS call, it also
determines wether report APN, uplink rate, downlink rate.
References
O
SIM PIN
3GPP TS 27.005
C
YES
M
Syntax
SI
Write Command
AT\V<value>
Execution Command
AT\V
Responses
OK
ERROR
Responses
Set default value: 0
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
41
2017-12-25
Smart Machine Smart Decision
Defined values
FI
L
E
<value>
0 – Don’t report
1 – Report communication protocol. And report APN, uplink rate, downlink rate if PS call.
Refer
to
AT&E.
The
maybe
communication
protocol
report
include
“NONE”,”PPPoverUD”,”AV32K”,”AV64K”,”PACKET”. And APN in string format while
uplink rate and downlink rate in integer format with kb unit.
Examples
AT&E
Set CONNECT Result Code Format About Speed
TI
3.25
AL
AT\V0
OK
EN
Description
SIM PIN
References
FI
3GPP TS 27.005
N
YES
D
This parameter setting determines to report Serial connection rate or Wireless connection speed. It
is valid only ATX above 0.
Responses
OK
C
Write Command
AT&E<value>
O
Syntax
ERROR
Responses
Set default value: 1
OK
O
M
Execution Command
AT&E
C
Defined values
SI
M
<value>
0 – Wireless connection speed in integer format.
1 – Serial connection rate in integer format. Such as: “115200”
Examples
AT&E0
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
42
2017-12-25
Smart Machine Smart Decision
3.26
AT&W Save the user setting to ME
Description
SIM PIN
References
3GPP TS 27.005
FI
L
YES
E
This command will save the user settings to ME which set by ATE, ATQ, ATV, ATX, AT&C AT&D,
AT&S, AT\V, AT+IFC and ATS0.
Write Command
AT&W<value>
AL
Syntax
Responses
OK
ERROR
FI
Defined values
O
N
<value>
0 – Save
C
Examples
M
AT&W0
OK
ATZ Restore the user setting from ME
O
3.27
EN
Responses
Set default value: 0
OK
D
Execution Command
AT&W
TI
ERROR
C
Description
M
This command will restore the user setting from ME which set by ATE, ATQ, ATV, ATX, AT&C
AT&D, AT&S, AT\Q, AT\V, and ATS0.
SI
SIM PIN
YES
References
3GPP TS 27.005
Syntax
Write Command
ATZ<value>
Responses
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
43
2017-12-25
Smart Machine Smart Decision
ERROR
Execution Command
ATZ
Responses
Set default value: 0
OK
E
ERROR
FI
L
Defined values
AL
<value>
0 – Restore
Examples
EN
3.28
TI
ATZ0
OK
AT+CGMI Request manufacturer identification
D
Description
3GPP TS 27.007
C
O
NO
References
N
SIM PIN
FI
This command is used to request the manufacturer identification text, which is intended to permit
the user of the Module to identify the manufacturer.
Syntax
Responses
OK
Execution Command
AT+CGMI
Responses
<manufacturer>
OK
C
O
M
Test Command
AT+CGMI=?
M
Defined values
SI
<manufacturer>
The identification of manufacturer.
Examples
AT+CGMI
SIMCOM INCORPORATED
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
44
2017-12-25
Smart Machine Smart Decision
3.29
AT+CGMM Request model identification
Description
SIM PIN
References
3GPP TS 27.007
FI
L
NO
E
This command is used to requests model identification text, which is intended to permit the user of
the Module to identify the specific model.
Execution Command
AT+CGMM
Responses
<model>
OK
D
Defined values
N
FI
<model>
The identification of model.
C
AT+CGMM
SIMCOM_SIM7600C
OK
O
Examples
AT+CGMR Request revision identification
M
3.30
TI
Responses
OK
EN
Test Command
AT+CGMM=?
AL
Syntax
O
Description
SI
M
C
This command is used to request product firmware revision identification text, which is intended to
permit the user of the Module to identify the version.
SIM PIN References
NO
3GPP TS 27.007
Syntax
Test Command
AT+CGMR=?
Responses
OK
Execution Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
45
2017-12-25
Smart Machine Smart Decision
AT+CGMR
+CGMR: <revision>
OK
Defined values
FI
L
E
<revision>
The revision identification of firmware.
Examples
AT+CGSN Request product serial number identification
EN
TI
3.31
AL
AT+CGMR
+CGMR: LE11B01SIM7600C
OK
Description
3GPP TS 27.007
N
NO
References
FI
SIM PIN
D
This command requests product serial number identification text, which is intended to permit the
user of the Module to identify the individual ME to which it is connected to.
Responses
<sn>
OK
O
M
Execution Command
AT+CGSN
Responses
OK
C
Test Command
AT+CGSN=?
O
Syntax
C
Defined values
SI
M
<sn>
Serial number identification, which consists of a single line containing the IMEI (International
Mobile station Equipment Identity) number of the MT.
If in CDMA/EVDO mode ,it will show ESN(Electronic Serial Number)
Examples
AT+CGSN
351602000330570
OK
AT+CGSN (CDMA/EVDO mode)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
46
2017-12-25
Smart Machine Smart Decision
0x8059D1F6
OK
AT+CSCS
Select TE character set
E
3.32
FI
L
Description
SIM PIN
References
TI
3GPP TS 27.007
EN
YES
AL
Write command informs TA which character set <chest> is used by the TE. TA is then able to
convert character strings correctly between TE and MT character sets.
Read command shows current setting and test command displays conversion schemes implemented
in the TA.
Syntax
FI
O
C
ERROR
Responses
Set subparameters as default value:
OK
O
M
Execution Command
AT+CSCS
N
Read Command
AT+CSCS?
Write Command
AT+CSCS=<chset>
Responses
+CSCS: (list of supported <chset>s)
OK
Responses
+CSCS: <chset>
OK
Responses
OK
D
Test Command
AT+CSCS=?
C
Defined values
SI
M
<chest>
Character set, the definition as following:
“IRA”
International reference alphabet.
“GSM” GSM default alphabet; this setting causes easily software flow control (XON
/XOFF) problems.
“UCS2” 16-bit universal multiple-octet coded character set; UCS2 character strings are
converted to hexadecimal numbers from 0000 to FFFF.
Examples
AT+CSCS=”IRA”
SIM7500_SIM7600 Series_AT Command Manual_V1.07
47
2017-12-25
Smart Machine Smart Decision
OK
AT+CSCS?
+CSCS:”IRA”
OK
E
AT+CIMI Request international mobile subscriber identity
FI
L
3.33
Description
SIM PIN
References
3GPP TS 27.007
EN
YES
TI
AL
Execution command causes the TA to return <IMSI>, which is intended to permit the TE to identify
the individual SIM card which is attached to MT.
NOTE: If USIM card contains two apps, like China Telecom 4G card, one RUIM/CSIM app, and
another USIM app; so there are two IMSI in it; AT+CIMI will return the RUIM/CSIM IMSI;
AT+CIMIM will return the USIM IMSI;
Responses
OK
Execution Command
AT+CIMI
ERROR
Responses
<IMSI>
OK
O
N
FI
Test Command
AT+CIMI=?
D
Syntax
C
ERROR
M
Defined values
O
<IMSI>
International Mobile Subscriber Identity (string, without double quotes).
C
Examples
SI
M
AT+CIMI
460010222028133
OK
3.34
AT+CIMIM Request another international mobile subscriber identity
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
48
2017-12-25
Smart Machine Smart Decision
Execution command causes the TA to return <IMSI>, which is intended to permit the TE to identify
the individual SIM card which is attached to MT.
NOTE: If USIM card contains two apps, like China Telecom 4G card, one RUIM/CSIM app, and
another USIM app; so there are two IMSI in it; AT+CIMIM will return the USIM IMSI; AT+CIMI
will return the RUIM/CSIM IMSI;
3GPP TS 27.007
FI
L
YES
References
E
SIM PIN
Test Command
Responses
AT+CIMIM=?
OK
AL
Syntax
Responses
AT+CIMIM
<IMSI>
OK
EN
Execution Command
TI
ERROR
D
ERROR
FI
Defined values
N
<IMSI>
International Mobile Subscriber Identity (string, without double quotes).
C
AT+GCAP Request overall capabilities
O
3.35
M
AT+CIMIM
460110222028133
OK
O
Examples
C
Description
M
Execution command causes the TA reports a list of additional capabilities.
SIM PIN
SI
YES
References
V.25ter
Syntax
Test Command
AT+GCAP=?
Responses
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
49
2017-12-25
Smart Machine Smart Decision
Execution Command
AT+GCAP
Responses
+GCAP: (list of <name>s)
OK
ERROR
AL
TI
EN
<name>
List of additional capabilities.
+CGSM
GSM function is supported
+FCLASS
FAX function is supported
+DS
Data compression is supported
+ES
Synchronous data mode is supported.
+CIS707-A CDMA data service command set
+CIS-856
EVDO data service command set
+MS
Mobile Specific command set
FI
L
E
Defined values
D
Examples
SI
M
C
O
M
C
O
N
FI
AT+GCAP
+GCAP:+CGSM,+FCLASS,+DS
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
50
2017-12-25
Smart Machine Smart Decision
4
E
AT+CFUN Set phone functionality
FI
L
4.1
AT Commands for Status Control
Description
SIM PIN
References
3GPP TS 27.007
D
NO
EN
TI
AL
This command is used to select the level of functionality <fun> in the ME. Level "full
functionality" is where the highest level of power is drawn. "Minimum functionality" is where
minimum power is drawn. Level of functionality between these may also be specified by
manufacturers. When supported by manufacturers, ME resetting with <rst> parameter may be
utilized.
NOTE: AT+CFUN=6 must be used after setting AT+CFUN=7. If module in offline mode, must
execute AT+CFUN=6 or restart module to online mode.
FI
Syntax
Responses
+CFUN: (list of supported <fun>s), (list of supported <rst>s)
OK
O
N
Test Command
AT+CFUN=?
C
ERROR
+CME ERROR: <err>
C
O
M
Read Command
AT+CFUN?
M
Write Command
AT+CFUN=<fun>[,<rst>]
Responses
+CFUN: <fun>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
SI
+CME ERROR: <err>
Defined values
<fun>
0
1
–
–
minimum functionality
full functionality, online mode
SIM7500_SIM7600 Series_AT Command Manual_V1.07
51
2017-12-25
Smart Machine Smart Decision
FI
L
E
4 – disable phone both transmit and receive RF circuits
5 – Factory Test Mode
6 – Reset
7 – Offline Mode
<rst>
0 – do not reset the ME before setting it to <fun> power level
1 – reset the ME before setting it to <fun> power level. This value only takes effect when
<fun> equals 1.
Examples
TI
EN
AT+CPIN Enter PIN
D
4.2
AL
AT+CFUN?
+CFUN: 1
OK
AT+CFUN=0
OK
FI
Description
SIM PIN
3GPP TS 27.007
O
Syntax
References
M
NO
C
O
N
This command is used to send the ME a password which is necessary before it can be operated
(SIM PIN, SIM PUK, PH-SIM PIN, etc.). If the PIN is to be entered twice, the TA shall
automatically repeat the PIN. If no PIN request is pending, no action is taken towards MT and an
error message, +CME ERROR, is returned to TE.
If the PIN required is SIM PUK or SIM PUK2, the second pin is required. This second pin,
<newpin>, is used to replace the old pin in the SIM.
M
C
Test Command
AT+CPIN=?
SI
Read Command
AT+CPIN?
Responses
OK
Responses
+CPIN: <code>
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CPIN=<pin>[,<newpin>
]
Responses
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
52
2017-12-25
Smart Machine Smart Decision
+CME ERROR: <err>
EN
TI
AL
FI
L
<pin>
String type values.
<newpin>
String type values.
<code>
Values reserved by the present document:
READY
– ME is not pending for any password
SIM PIN
– ME is waiting SIM PIN to be given
SIM PUK
– ME is waiting SIM PUK to be given
PH-SIM PIN – ME is waiting phone-to-SIM card password to be given
SIM PIN2
– ME is waiting SIM PIN2 to be given
SIM PUK2
– ME is waiting SIM PUK2 to be given
PH-NET PIN – ME is waiting network personalization password to be given
E
Defined values
D
Examples
N
O
AT+CICCID Read ICCID from SIM card
C
4.3
FI
AT+CPIN?
+CPIN: SIM PUK2
OK
Description
This command is used to Read the ICCID from SIM card
Vendor
O
NO
References
M
SIM PIN
M
C
Syntax
Responses
OK
Execution Command
AT+CICCID
Responses
+ICCID: <ICCID>
OK
SI
Test Command
AT+CICCID=?
ERROR
+CME ERROR: <err>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
53
2017-12-25
Smart Machine Smart Decision
Defined values
E
<ICCID>
Integrate circuit card identity, a standard ICCID is a 20-digit serial number of the SIM card,
it presents the publish state, network code, publish area, publish date, publish manufacture and
press serial number of the SIM card.
FI
L
Examples
AT+CSIM Generic SIM access
TI
4.4
AL
AT+CICCID
+ICCID: 898600700907A6019125
OK
EN
Description
3GPP TS 27.007
C
NO
References
Syntax
O
M
Test Command
AT+CSIM=?
M
C
Write Command
AT+CSIM=<length>,<com
mand>
SI
O
SIM PIN
N
FI
D
This command is used to control the SIM card directly.
Compared to restricted SIM access command AT+CRSM, AT+CSIM allows the ME to take more
control over the SIM interface.
For SIM–ME interface please refer 3GPP TS 11.11.
NOTE:The SIM Application Toolkit functionality is not supported by AT+CSIM. Therefore the
following SIM commands can not be used: TERMINAL PROFILE, ENVELOPE,
FETCH and TEMINAL RESPONSE.
Responses
OK
Responses
+CSIM: <length>, <response>
OK
ERROR
+CME ERROR: <err>
Defined values
<length>
Interger type; length of characters that are sent to TE in <command> or <response>
<command>
Command passed from MT to SIM card.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
54
2017-12-25
Smart Machine Smart Decision
<response>
Response to the command passed from SIM card to MT.
Examples
FI
L
4.5
E
AT+CSIM=?
OK
AT+CRSM Restricted SIM access
AL
Description
3GPP TS 27.007
M
Write Command
AT+CRSM=<command>[,<f
ileID>[,<p1>,<p2>, <p3>
[,<data>]]]
Responses
+CRSM: <sw1>,<sw2>[,<response>]
OK
ERROR
+CME ERROR: <err>
C
O
Responses
OK
C
Test Command
AT+CRSM=?
O
N
Syntax
FI
NO
References
D
SIM PIN
EN
TI
By using AT+CRSM instead of Generic SIM Access AT+CSIM, TE application has easier but
more limited access to the SIM database.
Write command transmits to the MT the SIM <command> and its required parameters. MT handles
internally all SIM-MT interface locking and file selection routines. As response to the command,
MT sends the actual SIM information parameters and response data. MT error result code +CME
ERROR may be returned when the command cannot be passed to the SIM, but failure in the
execution of the command in the SIM is reported in <sw1> and <sw2> parameters.
M
Defined values
SI
<command>
Command passed on by the MT to the SIM:
176 – READ BINARY
178 – READ RECORD
192 – GET RESPONSE
214 – UPDATE BINARY
220 – UPDATE RECORD
242 – STATUS
203 – RETRIEVE DATA
SIM7500_SIM7600 Series_AT Command Manual_V1.07
55
2017-12-25
FI
L
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
219 – SET DATA
<fileID>
Identifier for an elementary data file on SIM, if used by <command>.
The following list the fileID hex value, user needs to convet them to decimal.
EFs under MF
0x2FE2
ICCID
0x2F05
Extended Language Preferences
0x2F00
EF DIR
0x2F06
Access Rule Reference
EFs under USIM ADF
0x6F05
Language Indication
0x6F07
IMSI
0x6F08
Ciphering and Integrity keys
0x6F09
C and I keys for pkt switched domain
0x6F60
User controlled PLMN selector w/Acc Tech
0x6F30
User controlled PLMN selector
0x6F31
HPLMN search period
0x6F37
ACM maximum value
0x6F38
USIM Service table
0x6F39
Accumulated Call meter
0x6F3E
Group Identifier Level
0x6F3F
Group Identifier Level 2
0x6F46
Service Provider Name
0x6F41
Price Per Unit and Currency table
0x6F45
Cell Bcast Msg identifier selection
0x6F78
Access control class
0x6F7B
Forbidden PLMNs
0x6F7E
Location information
0x6FAD
Administrative data
0x6F48
Cell Bcast msg id for data download
0x6FB7
Emergency call codes
0x6F50
Cell bcast msg id range selection
0x6F73
Packet switched location information
0x6F3B
Fixed dialling numbers
0x6F3C
Short messages
0x6F40
MSISDN
0x6F42
SMS parameters
0x6F43
SMS Status
0x6F49
Service dialling numbers
0x6F4B
Extension 2
0x6F4C
Extension 3
0x6F47
SMS reports
0x6F80
Incoming call information
E
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07
56
2017-12-25
FI
L
AL
TI
C
O
N
FI
D
EN
Outgoing call information
Incoming call timer
Outgoing call timer
Extension 5
Capability Config Parameters 2
Enh Multi Level Precedence and Pri
Automatic answer for eMLPP service
Group identity
Key for hidden phonebook entries
Barred dialling numbers
Extension 4
Comparison Method information
Enabled services table
Access Point Name Control List
De-personalization Control Keys
Co-operative network list
Hyperframe number
Maximum value of Hyperframe number
OPLMN selector with access tech
OPLMN selector
HPLMN selector with access technology
Access Rule reference
RPLMN last used access tech
Network Parameters
CPHS: Voice Mail Waiting Indicator
CPHS: Service String Table
CPHS: Call Forwarding Flag
CPHS: Operator Name String
CPHS: Customer Service Profile
CPHS: CPHS Information
CPHS: Mailbox Number
PLMN Network Name
Operator PLMN List
Dynamic Flags Status
Dynamic2 Flag Setting
Customer Service Profile Line2
EF PARAMS - Welcome Message
Phone book reference file
Phone book synchronization center
Change counter
Previous Unique Identifier
GSM ciphering key Kc
GPRS ciphering key
SI
M
C
O
M
0x6F81
0x6F82
0x6F83
0x6F4E
0x6F4F
0x6FB5
0x6FB6
0x6FC2
0x6FC3
0x6F4D
0x6F55
0x6F58
0x6F56
0x6F57
0x6F2C
0x6F32
0x6F5B
0x6F5C
0x6F61
0x6F5D
0x6F62
0x6F06
0x6F65
0x6FC4
0x6F11
0x6F12,
0x6F13
0x6F14
0x6F15
0x6F16
0x6F17
0x6FC5
0x6FC6
0x6F9F
0x6F92
0x6F98
0x6F9B
0x4F30
0x4F22
0x4F23
0x4F24
0x4F20
0x4F52
E
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07
57
2017-12-25
FI
L
AL
TI
SI
M
C
O
M
C
O
N
FI
D
EN
0x4F63
CPBCCH information
0x4F64
Investigation scan
0x4F40
MExE Service table
0x4F41
Operator Root Public Key
0x4F42
Administrator Root Public Key
0x4F43
Third party Root public key
0x6FC7
Mail Box Dialing Number
0x6FC8
Extension 6
0x6FC9
Mailbox Identifier
0x6FCA
Message Waiting Indication Status
0x6FCD
Service Provider Display Information
0x6FD2
UIM_USIM_SPT_TABLE
0x6FD9
Equivalent HPLMN
0x6FCB
Call Forwarding Indicator Status
0x6FD6
GBA Bootstrapping parameters
0x6FDA
GBA NAF List
0x6FD7
MBMS Service Key
0x6FD8
MBMS User Key
0x6FCE
MMS Notification
0x6FD0
MMS Issuer connectivity parameters
0x6FD1
MMS User Preferences
0x6FD2
MMS User connectivity parameters
0x6FCF
Extension 8
0x5031
Object Directory File
0x5032
Token Information File
0x5033
Unused space Information File
EFs under Telecom DF
0x6F3A
Abbreviated Dialing Numbers
0x6F3B
Fixed dialling numbers
0x6F3C
Short messages
0x6F3D
Capability Configuration Parameters
0x6F4F
Extended CCP
0x6F40
MSISDN
0x6F42
SMS parameters
0x6F43
SMS Status
0x6F44
Last number dialled
0x6F49
Service Dialling numbers
0x6F4A
Extension 1
0x6F4B
Extension 2
0x6F4C
Extension 3
0x6F4D
Barred Dialing Numbers
0x6F4E
Extension 4
0x6F47
SMS reports
E
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07
58
2017-12-25
Smart Machine Smart Decision
FI
D
EN
TI
AL
FI
L
E
0x6F58
Comparison Method Information
0x6F54
Setup Menu elements
0x6F06
Access Rule reference
0x4F20
Image
0x4F30
Phone book reference file
0x4F22
Phone book synchronization center
0x4F23
Change counter
0x4F24
Previous Unique Identifier
<p1> <p2> <p3>
Integer type; parameters to be passed on by the Module to the SIM.
<data>
Information which shall be written to the SIM (hexadecimal character format, refer AT+CSCS).
<sw1> <sw2>
Status information from the SIM about the execution of the actual command. It is returned in both
cases, on successful or failed execution of the command.
<response>
Response data in case of a successful completion of the previously issued command.
“STATUS” and “GET RESPONSE” commands return data, which gives information about the
currently selected elementary data field. This information includes the type of file and its size.
After “READ BINARY” or “READ RECORD” commands the requested data will be returned.
<response> is empty after “UPDATE BINARY” or “UPDATE RECORD” commands.
N
Examples
C
AT+SPIC Times remain to input SIM PIN/PUK
M
4.6
O
AT+CRSM=?
OK
Description
O
This command is used to inquire times remain to input SIM PIN/PUK.
C
SIM PIN
Vendor
M
NO
References
SI
Syntax
Test Command
AT+SPIC=?
Responses
OK
Execution Command
AT+SPIC
Responses
+SPIC: <pin1>,<puk1>,<pin2>,<puk2>
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
59
2017-12-25
Smart Machine Smart Decision
Defined values
FI
L
E
<pin1>
Times remain to input PIN1 code.
<puk1>
Times remain to input PUK1 code.
<pin2>
Times remain to input PIN2 code.
<puk2>
Times remain to input PUK2 code.
AL
Examples
EN
D
AT+CSPN Get service provider name from SIM
FI
4.7
TI
AT+SPIC=?
OK
AT+SPIC
+SPIC: 3,10,0,10
OK
N
Description
YES
References
Vendor
C
SIM PIN
O
This command is used to get service provider name from SIM card.
Syntax
O
M
Test Command
AT+CSPN=?
SI
M
C
Read Command
AT+CSPN?
Responses
OK
ERROR
Responses
+CSPN: <spn>,<display mode>
OK
OK
ERROR
+CME ERROR: <err>
Defined values
<spn>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
60
2017-12-25
Smart Machine Smart Decision
String type; service provider name on SIM
<display mode>
0 – doesn’t display PLMN. Already registered on PLMN.
1 – display PLMN
E
Examples
AL
AT+CSQ Query signal quality
EN
Description
TI
4.8
FI
L
AT+CSPN=?
OK
AT+CSPN?
+CSPN: “CMCC”,0
OK
SIM PIN
References
3GPP TS 27.007
Responses
+CSQ: <rssi>,<ber>
OK
ERROR
C
O
M
Execution Command
AT+CSQ
Responses
+CSQ: (list of supported <rssi>s),(list of supported <ber>s)
OK
C
Test Command
AT+CSQ=?
O
N
Syntax
FI
NO
D
This command is used to return received signal strength indication <rssi> and channel bit error rate
<ber> from the ME. Test command returns values supported by the TA as compound values.
M
Defined values
SI
<rssi>
0
–
1
–
2...30
–
31
–
99
–
100
–
101
–
102…191 –
-113 dBm or less
-111 dBm
-109... -53 dBm
-51 dBm or greater
not known or not detectable
-116 dBm or less
-115 dBm
-114... -26dBm
SIM7500_SIM7600 Series_AT Command Manual_V1.07
61
2017-12-25
FI
L
EN
Examples
Set CSQ report
N
AT+AUTOCSQ
FI
D
AT+CSQ
+CSQ: 22,0
OK
4.9
AL
TI
191
–
-25 dBm or greater
199
–
not known or not detectable
100…199 –
expand to TDSCDMA, indicate RSCP received
<ber>
(in percent)
0
– <0.01%
1
– 0.01% --- 0.1%
2
– 0.1% --- 0.5%
3
– 0.5% --- 1.0%
4
– 1.0% --- 2.0%
5
– 2.0% --- 4.0%
6
– 4.0% --- 8.0%
7
– >=8.0%
99 – not known or not detectable
E
Smart Machine Smart Decision
O
Description
C
This command is used to enable or disable automatic report CSQ information, when automatic
report enabled, the module reports CSQ information every five seconds or only after <rssi> or
<ber> is changed, the format of automatic report is “+CSQ: <rssi>,<ber>”.
Vendor
O
NO
References
M
SIM PIN
C
Syntax
SI
M
Test Command
AT+AUTOCSQ=?
Responses
+AUTOCSQ: (list of supported<auto>s),(list of supported<mod
e>s)
OK
Read Command
AT+AUTOCSQ?
Responses
+AUTOCSQ: <auto>,<mode>
OK
Write Command
AT+AUTOCSQ=<auto>[,<
Responses
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
62
2017-12-25
Smart Machine Smart Decision
mode>]
ERROR
Defined values
AL
FI
L
E
<auto>
0 – disable automatic report
1 – enable automatic report
<mode>
0 – CSQ automatic report every five seconds
1 – CSQ automatic report only after <rssi> or <ber> is changed
NOTE: If the parameter of <mode> is omitted when executing write command, <mode> will be set
to default value.
EN
D
AT+CSQDELTA Set RSSI delta change threshold
C
4.10
O
N
FI
AT+AUTOCSQ=?
+AUTOCSQ: (0-1),(0-1)
OK
AT+AUTOCSQ?
+AUTOCSQ: 1,1
OK
AT+AUTOCSQ=1,1
OK
+CSQ: 23,0 (when <rssi> or <ber> changing)
TI
Examples
Description
M
This command is used to set RSSI delta threshold for signal strength reporting.
SIM PIN
Vendor
C
O
NO
References
M
Syntax
Responses
+CSQDELTA: (list of supported <delta>s)
OK
Read Command
AT+CSQDELTA?
Responses
+CSQDELTA: <delta>
SI
Test Command
AT+CSQDELTA=?
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
63
2017-12-25
Smart Machine Smart Decision
Write Command
AT+CSQDELTA=<delta>
Responses
OK
ERROR
E
Responses
Set default value(<delta>=5):
OK
FI
L
Execution Command
AT+CSQDELTA
Defined values
AL
<delta>
Range: from 0 to 5.
TI
Examples
Configure URC destination interface
D
AT+CATR
FI
4.11
EN
AT+CSQDELTA?
+CSQDELTA: 5
OK
Description
SIM PIN
Vendor
O
Syntax
References
M
NO
C
O
N
This command is used to configure the serial port which will be used to output URCs. We
recommend configure a destination port for receiving URC in the system initialization phase, in
particular, in the case that transmitting large amounts of data, e.g. use TCP/UDP and MT SMS
related AT command.
M
C
Test Command
AT+CATR=?
SI
Read Command
AT+CATR?
Write Command
AT+CATR=<port>
Responses
+CATR: (list of supported <port>s)
OK
Responses
+CATR: <port>
OK
Responses
OK
ERROR
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
64
2017-12-25
Smart Machine Smart Decision
all ports
use UART port to output URCs
use MODEM port to output URCs
use ATCOM port to output URCs
use cmux vritual port1 to output URCs
use cmux virtual port2 to output URCs
use cmux vritual port3 to output URCs
use cmux vritual port4 to output URCs
E
–
–
–
–
–
–
–
–
FI
L
<port>
0
1
2
3
4
5
6
7
AL
Examples
EN
D
FI
AT+CPOF Power down the module
N
4.12
TI
AT+CATR=1
OK
AT+CATR?
+CATR: 1
OK
O
Description
SIM PIN
Vendor
O
Syntax
References
M
NO
C
This command is used to power off the module. Once the AT+CPOF command is executed, The
module will store user data and deactivate from network, and then shutdown.
Responses
OK
Execution Command
AT+CPOF
Responses
OK
SI
M
C
Test Command
AT+CPOF=?
Examples
AT+CPOF
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
65
2017-12-25
Smart Machine Smart Decision
4.13
AT+CRESET Reset the module
Description
NO
References
FI
L
SIM PIN
E
This command is used to reset the module.
Vendor
Execution Command
AT+CRESET
Responses
OK
TI
Responses
OK
EN
Test Command
AT+CRESET=?
AL
Syntax
D
Examples
N
O
AT+CACM
Accumulated call meter
C
4.14
FI
AT+CRESET=?
OK
AT+CRESET
OK
Description
M
This command is used to reset the Advice of Charge related accumulated call meter value in SIM
file EFACM.
References
O
SIM PIN
3GPP TS 27.007
C
YES
M
Syntax
SI
Test Command
AT+CACM=?
Read Command
AT+CACM?
Responses
OK
ERROR
Responses
+CACM: <acm>
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
66
2017-12-25
Smart Machine Smart Decision
+CME ERROR: <err>
Write Command
AT+CACM=<passwd>
Responses
OK
ERROR
Responses
AT+CACM
OK
FI
L
Execution Command
E
+CME ERROR: <err>
ERROR
AL
+CME ERROR: <err>
Defined values
EN
TI
<passwd>
String type, SIM PIN2.
<acm>
String type, accumulated call meter value similarly coded as <ccm> under +CAOC.
D
Examples
N
O
AT+CAMM
Accumulated call meter maximum
C
4.15
FI
AT+CACM?
+CACM: "000000"
OK
Description
M
This command is used to set the Advice of Charge related accumulated call meter maximum value
in SIM file EFACMmax.
References
O
SIM PIN
3GPP TS 27.007
C
YES
M
Syntax
SI
Test Command
AT+CAMM=?
Read Command
AT+CAMM?
Responses
OK
ERROR
Responses
+CAMM: <acmmax>
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
67
2017-12-25
Smart Machine Smart Decision
+CME ERROR: <err>
Write Command
AT+CAMM=
<acmmax>[,<passwd>]
Responses
OK
ERROR
FI
L
E
+CME ERROR: <err>
Responses
OK
Execution Command
AT+CAMM
ERROR
AL
+CME ERROR: <err>
Defined values
D
EN
TI
<acmmax>
String type, accumulated call meter maximum value similarly coded as <ccm> under AT+CAOC,
value zero disables ACMmax feature.
<passwd>
String type, SIM PIN2.
FI
Examples
O
AT+CPUC Price per unit and currency table
C
4.16
N
AT+CAMM?
+CAMM: "000000"
OK
Description
M
This command is used to set the parameters of Advice of Charge related price per unit and currency
table in SIM file EFPUCT..
References
O
SIM PIN
C
YES
3GPP TS 27.007
M
Syntax
SI
Test Command
AT+CPUC=?
Responses
OK
ERROR
Read Command
AT+CPUC?
Responses
+CPUC: [<currency>,<ppu>]
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
68
2017-12-25
Smart Machine Smart Decision
ERROR
+CME ERROR: <err>
Write Command
AT+CPUC=<currency>,<pp
u>[,<passwd>]
Responses
OK
ERROR
FI
L
E
+CME ERROR: <err>
Defined values
EN
TI
AL
<currency>
String type, three-character currency code (e.g. "GBP", "DEM"), character set as specified by
command Select TE Character Set AT+CSCS.
<ppu>
String type, price per unit, dot is used as a decimal separator. (e.g. "2.66").
<passwd>
String type, SIM PIN2.
D
Examples
N
Real time clock management
O
AT+CCLK
C
4.17
FI
AT+CPUC?
+CPUC: “GBP” , “2.66”
OK
Description
This command is used to manage Real Time Clock of the module.
3GPP TS 27.007
O
NO
References
M
SIM PIN
C
Syntax
SI
M
Test Command
AT+CCLK=?
Read Command
AT+CCLK?
Responses
OK
Responses
+CCLK: <time>
OK
Write Command
AT+CCLK=<time>
Responses
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
69
2017-12-25
Smart Machine Smart Decision
Defined values
FI
L
E
<time>
String type value; format is “yy/MM/dd,hh:mm:ss±zz”, where characters indicate year (two last
digits), month, day, hour, minutes, seconds and time zone (indicates the difference, expressed in
quarters of an hour, between the local time and GMT; three last digits are mandatory, range
-47…+48). E.g. 6th of May 2008, 14:28:10 GMT+8 equals to “08/05/06,14:28:10+32”.
NOTE: 1. Time zone is nonvolatile, and the factory value is invalid time zone.
2. Command +CCLK? will return time zone when time zone is valid, and if time zone is
00, command +CCLK? will return “+00”, but not “-00”.
TI
EN
D
FI
O
AT+CMEE Report mobile equipment error
C
4.18
N
AT+CCLK=“08/11/28,12:30:33+32”
OK
AT+CCLK?
+CCLK: “08/11/28,12:30:35+32”
OK
AT+CCLK=“08/11/26,10:15:00”
OK
AT+CCLK?
+CCLK: “08/11/26,10:15:02+32”
OK
AL
Examples
Description
M
This command is used to disable or enable the use of result code “+CME ERROR: <err>” or
“+CMS ERROR: <err>” as an indication of an error relating to the functionality of ME; when
enabled, the format of <err> can be set to numeric or verbose string.
References
O
SIM PIN
3GPP TS 27.007
C
NO
M
Syntax
Responses
+CMEE: (list of supported <n>s)
OK
Read Command
AT+CMEE?
Responses
+CMEE: <n>
OK
Write Command
Responses
SI
Test Command
AT+CMEE=?
SIM7500_SIM7600 Series_AT Command Manual_V1.07
70
2017-12-25
Smart Machine Smart Decision
OK
Execution Command
AT+CMEE
ERROR
Responses
Set default value:
OK
E
AT+CMEE=<n>
FI
L
Defined values
0
1
2
– Disable result code,i.e. only “ERROR” will be displayed.
– Enable error result code with numeric values.
– Enable error result code with string values.
EN
D
FI
C
O
N
AT+CMEE?
+CMEE: 2
OK
AT+CPIN="1234","1234"
+CME ERROR: incorrect password
AT+CMEE=0
OK
AT+CPIN="1234","1234"
ERROR
AT+CMEE=1
OK
AT+CPIN="1234","1234"
+CME ERROR: 16
TI
Examples
AL
<n>
Phone activity status
M
AT+CPAS
O
4.19
C
Description
M
This command is used to return the activity status <pas> of the ME. It can be used to interrogate the
ME before requesting action from the phone.
SI
SIM PIN
NO
References
3GPP TS 27.007
Syntax
Test Command
AT+CPAS=?
Responses
+CPAS: (list of supported <pas>s)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
71
2017-12-25
Smart Machine Smart Decision
Execution Command
AT+CPAS
Responses
+CPAS: <pas>
OK
– ready (ME allows commands from TA/TE)
– ringing (ME is ready for commands from TA/TE, but the ringer is active)
– call in progress (ME is ready for commands from TA/TE, but a call is in progress)
FI
L
<pas>
0
3
4
AL
Examples
FI
D
EN
TI
RING (with incoming call)
AT+CPAS
+CPAS: 3
OK
AT+CPAS=?
+CPAS: (0,3,4)
OK
AT+SIMEI Set IMEI for the module
N
4.20
E
Defined values
O
Description
SIM PIN
Vendor
O
Syntax
References
M
NO
C
This command is used to set the module’s IMEI value.
M
C
Test Command
AT+SIMEI=?
Responses
OK
Responses
+SIMEI: <imei>
OK
Write Command
AT+SIMEI=<imei>
Responses
OK
SI
Read Command
AT+SIMEI?
ERROR
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
72
2017-12-25
Smart Machine Smart Decision
<imei>
The 15-digit IMEI value.
Examples
FI
L
AL
AT+SMEID Request Mobile Equipment Identifier
TI
4.21
E
AT+SIMEI=357396012183170
OK
AT+SIMEI?
+SIMEI: 357396012183170
OK
AT+SIMEI=?
OK
EN
Description
SIM PIN
References
FI
3GPP TS 27.007
N
NO
D
Only task effect in 7600CE
C
Responses
+SMEID: <MEID>
OK
ERROR
M
Read Command
AT+SMEID?
O
Syntax
O
Defined values
C
<MEID>
Mobile Equipment Identifier (string, without double quotes).
M
Examples
SI
AT+SMEID?
+SMEID: A1000021A5906F
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
73
2017-12-25
Smart Machine Smart Decision
4.22
AT+CSVM
Voice Mail Subscriber number
Description
Execution command returns the voice mail number related to the subscriber.
3GPP TS 27.007
FI
L
YES
References
E
SIM PIN
Test Command
AT+CSVM=?
Responses
+CSVM: (0-1), “(0-9,+)”, (128-255)
OK
Responses
EN
Read Command
AT+CSVM?
TI
ERROR
AL
Syntax
+CSVM: <valid>, “<number>”,<type>
ERROR
Responses
AT+CSVM=<valid>,
“<number>”,<type>
OK
FI
Write Command
D
OK
O
N
ERROR
C
Defined values
M
C
O
M
<valid>
Whether voice mail number is valid:
0 – Voice mail number is invalid.
1 – Voice mail number is valid.
<number>
String type phone number of format specified by <type>.
<type>
Type of address octet in integer format. see also AT+CPBR <type>
SI
Examples
AT+CSVM?
+CSVM: 1 ,"13697252277",129
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
74
2017-12-25
Smart Machine Smart Decision
4.23
AT+CUSBPIDSWITCH Change module’s PID
Description
SIM PIN
References
Vendor
FI
L
NO
E
Execution command change the module’s PID. This command will reset the module if change to
other PID (not current used PID).
AL
Syntax
Responses
+CUSBPIDSWITCH:
(9000,9001,9002,9003,9004,9005,9006,9007,9011),(0-1),(0-1)
OK
TI
Test Command
AT+CUSBPIDSWITCH=?
Read Command
AT+CUSBPIDSWITCH?
EN
ERROR
Responses
D
+CUSBPIDSWITCH: <pid>
FI
OK
ERROR
Responses
AT+CUSBPIDSWITCH=<p
id>, < reserve1>,< reserve2>
OK
O
N
Write Command
C
Defined values
ERROR
M
C
O
M
<pid>
This command support pids, 9001 is the default value.
9000,9001,9002,9003,9004,9005,9006,9007,9011
< reserve1>
0 or 1, this value is for the reserve
< reserve2>
0 or 1, this value is for the reserve
SI
Examples
AT+CUSBPIDSWITCH?
+CUSBPIDSWITCH: 9001
OK
AT+CUSBPIDSWITCH=9001,1,1
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
75
2017-12-25
Smart Machine Smart Decision
4.24
Indication of EONS
This module supports EONS function; the following table shows the URC related EONS.
Description
This indication means EF-OPL has been read successfully. Only
after this URC is reported, the AT+COPS? can query the network
name that supports EONS function.
PNN INIT
PNN DONE
Description
This indication means EF-PNN has been read successfully
OPL UPDATING
OPL UPDATING
Description
This indication means the EF-OPL is updating using OTA message.
After updating, the “OPL DONE” should report.
Description
This indication means the EF-PNN is updating using OTA
message. After updating, the “PNN DONE” should report.
AL
FI
L
E
OPL INIT
OPL DONE
EN
TI
PNN UPDATING
PNN UPDATING
D
Indication of Voice Mail
N
4.25
This indication means the EF-PNN is updating using OTA
message. After updating, the “PNN DONE” should report.
FI
PNN UPDATING
Description
This indication means the voice mail box is empty
C
Box Empty
+VOICEMAIL: EMPTY
O
This module supports voice mail function; the subscriber number is configured by AT+CSVM
command, the following table shows the URC related Voice Mail.
M
New Message
+VOICEMAIL: NEW MSG
Description
This indication means that there are <count> number of voice
mail messages that needs to be got.
M
C
O
Voice Mail Status Updated
+VOICEMAIL: WAITING,
<count>
Description
This indication means there is a new voice mail message
notification received. This is for CPHS.
SI
Defined values
< count>
Count of voice mail message that waits to be got.
Examples
+VOICEMAIL: WAITING, <count>
+VOICEMAIL: WAITING, 5
SIM7500_SIM7600 Series_AT Command Manual_V1.07
76
2017-12-25
Smart Machine Smart Decision
5
AT+CREG Network registration
E
5.1
AT Commands for Network
FI
L
Description
NO
References
EN
SIM PIN
TI
AL
This command is used to control the presentation of an unsolicited result code +CREG: <stat>
when <n>=1 and there is a change in the ME network registration status, or code +CREG:
<stat>[,<lac>,<ci>] when <n>=2 and there is a change of the network cell.
Read command returns the status of result code presentation and an integer <stat> which shows
whether the network has currently indicated the registration of the ME. Location information
elements <lac> and <ci> are returned only when <n>=2 and ME is registered in the network.
3GPP TS 27.007
D
Syntax
Responses
+CREG: (list of supported <n>s)
OK
Read Command
AT+CREG?
Responses
+CREG: <n>,<stat>[,<lac>,<ci>]
O
N
FI
Test Command
AT+CREG=?
C
OK
ERROR
M
+CME ERROR: <err>
C
O
Write Command
AT+CREG=<n>
SI
M
Execution Command
AT+CREG
Responses
OK
ERROR
+CME ERROR: <err>
Responses
Set default value(<n>=0):
OK
Defined values
<n>
0
1
2
– disable network registration unsolicited result code
– enable network registration unsolicited result code +CREG: <stat>
– enable network registration and location information unsolicited result code +CREG:
SIM7500_SIM7600 Series_AT Command Manual_V1.07
77
2017-12-25
Smart Machine Smart Decision
FI
Examples
C
O
N
AT+CREG?
+CREG: 0,1
OK
5.2
TI
The <ci> not supported in CDMA/HDR mode
D
NOTE:
EN
NOTE: The <lac> not supported in CDMA/HDR mode
<ci>
Cell Identify in hexadecimal format.
GSM : Maximum is two byte
WCDMA : Maximum is four byte
TDS-CDMA : Maximum is four byte
AL
FI
L
E
<stat>[,<lac>,<ci>]
<stat>
0 – not registered, ME is not currently searching a new operator to register to
1 – registered, home network
2 – not registered, but ME is currently searching a new operator to register to
3 – registration denied
4 – unknown
5 – registered, roaming
<lac>
Two byte location area code in hexadecimal format(e.g.”00C3” equals 193 in decimal).
AT+COPS Operator selection
SI
M
C
O
M
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
78
2017-12-25
Smart Machine Smart Decision
SIM PIN
References
D
3GPP TS 27.007
FI
YES
EN
TI
AL
FI
L
E
Write command forces an attempt to select and register the GSM/UMTS network operator. <mode>
is used to select whether the selection is done automatically by the ME or is forced by this
command to operator <oper> (it shall be given in format <format>). If the selected operator is not
available, no other operator shall be selected (except <mode>=4). The selected operator name
format shall apply to further read commands (AT+COPS?) also. <mode>=2 forces an attempt to
deregister from the network. The selected mode affects to all further network registration (e.g. after
<mode>=2, ME shall be unregistered until <mode>=0 or 1 is selected).
Read command returns the current mode and the currently selected operator. If no operator is
selected, <format> and <oper> are omitted.
Test command returns a list of quadruplets, each representing an operator present in the network.
Quadruplet consists of an integer indicating the availability of the operator <stat>, long and short
alphanumeric format of the name of the operator, and numeric format representation of the operator.
Any of the formats may be unavailable and should then be an empty field. The list of operators shall
be in order: home network, networks referenced in SIM, and other networks.
It is recommended (although optional) that after the operator list TA returns lists of supported
<mode>s and <format>s. These lists shall be delimited from the operator list by two commas.
When executing AT+COPS=? , any input from serial port will stop this command.
N
Syntax
Responses
[+COPS: [list of supported (<stat>,long alphanumeric <oper>
O
Test Command
AT+COPS=?
,short alphanumeric <oper>,numeric <oper>[,< AcT>])s]
C
[,,(list of supported <mode>s),(list of supported <format>s)]]
OK
M
ERROR
SI
M
C
O
Read Command
AT+COPS?
Write Command
AT+COPS=<mode>[,<form
at>[,<oper>[,< AcT>]]]
+CME ERROR: <err>
Responses
+COPS: <mode>[,<format>,<oper>[,< AcT>]]
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Execution Command
AT+COPS
Responses
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
79
2017-12-25
Smart Machine Smart Decision
Defined values
E
automatic
manual
force deregister
set only <format>
manual/automatic
manual,but do not modify the network selection mode(e.g GSM,WCDMA) after
module resets.
FI
L
<mode>
0 –
1 –
2 –
3 –
4 –
5 –
M
C
O
N
FI
D
EN
TI
AL
NOTE: if <mode> is set to 1, 4, 5 in write command, the <oper> is needed.
<format>
0 – long format alphanumeric <oper>
1 – short format alphanumeric <oper>
2 – numeric <oper>
<oper>
string type, <format> indicates if the format is alphanumeric or numeric.
<stat>
0 – unknown
1 – available
2 – current
3 – forbidden
<AcT>
Access technology selected
0 – GSM
1 – GSM Compact
2 – UTRAN
7 – EUTRAN
8 – CDMA/HDR
C
O
NOTE: the value 8 do not follow the 3gpp spec, we add this value to distinguish cdma/hdr.
M
Examples
SI
AT+COPS?
+COPS: 0,0,"China Mobile Com",0
OK
AT+COPS=?
+COPS: (2,"China Unicom","Unicom","46001",0),(3,"China Mobile Com","DGTMPT",
"46000",0),,(0,1,2,3,4,5),(0,1,2)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
80
2017-12-25
Smart Machine Smart Decision
5.3
AT+CLCK Facility lock
Description
SIM PIN
References
3GPP TS 27.007
Syntax
Responses
+CLCK: (list of supported <fac>s)
TI
Test Command
AT+CLCK=?
AL
YES
FI
L
E
This command is used to lock, unlock or interrogate a ME or a network facility <fac>. Password is
normally needed to do such actions. When querying the status of a network service (<mode>=2) the
response line for 'not active' case (<status>=0) should be returned only if service is not active for
any <class>.
EN
OK
ERROR
FI
Responses
OK
When <mode>=2 and command successful:
N
Write Command
AT+CLCK=<fac>,<mode>
[,<passwd>[,<class>]]
D
+CME ERROR: <err>
+CLCK:<status>[,<class1>[<CR><LF>
O
+CLCK: <status>,<class2>
C
[...]]
OK
M
ERROR
+CME ERROR: <err>
O
Defined values
SI
M
C
<fac>
"PF"
"SC"
"AO"
"OI"
"OX"
"AI"
"IR"
"AB"
"AG"
"AC"
lock Phone to the very First inserted SIM card or USIM card
lock SIM card or USIM card
Barr All Outgoing Calls
Barr Outgoing International Calls
Barr Outgoing International Calls except to Home Country
Barr All Incoming Calls
Barr Incoming Calls when roaming outside the home country
All Barring services (only for <mode>=0)
All outGoing barring services (only for <mode>=0)
All inComing barring services (only for <mode>=0)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
81
2017-12-25
Smart Machine Smart Decision
Examples
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
"FD"
SIM fixed dialing memory feature
"PN"
Network Personalization
"PU"
network subset Personalization
"PP"
service Provider Personalization
"PC"
Corporate Personalization
<mode>
0 – unlock
1 – lock
2 – query status
<status>
0 – not active
1 – active
<passwd>
Password.
string type; shall be the same as password specified for the facility from the ME user interface or
with command Change Password +CPWD
<classX>
It is a sum of integers each representing a class of information (default 7):
1
– voice (telephony)
2
– data (refers to all bearer services)
4
– fax (facsimile services)
8
– short message service
16
– data circuit sync
32 – data circuit async
64
– dedicated packet access
128 – dedicated PAD access
255 – The value 255 covers all classes
AT+CPWD Change password
SI
M
5.4
C
O
AT+CLCK="SC",2
+CLCK: 0
OK
Description
Write command sets a new password for the facility lock function defined by command Facility
Lock AT+CLCK.
Test command returns a list of pairs which present the available facilities and the maximum length
of their password.
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
82
2017-12-25
Smart Machine Smart Decision
YES
3GPP TS 27.007
Syntax
Responses
+CPWD: (list of supported (<fac>,<pwdlength>)s)
E
Test Command
AT+CPWD=?
FI
L
OK
ERROR
+CME ERROR: <err>
AL
Responses
OK
ERROR
+CME ERROR: <err>
EN
Defined values
TI
Write Command
AT+CPWD=
<fac>,<oldpwd>,<newpwd>
SI
M
C
O
M
C
O
N
FI
D
<fac>
Refer Facility Lock +CLCK for other values:
"SC" SIM or USIM PIN1
"P2" SIM or USIM PIN2
"AB" All Barring services
"AC" All inComing barring services (only for <mode>=0)
"AG" All outGoing barring services (only for <mode>=0)
"AI" Barr All Incoming Calls
"AO" Barr All Outgoing Calls
"IR" Barr Incoming Calls when roaming outside the home country
"OI" Barr Outgoing International Calls
"OX" Barr Outgoing International Calls except to Home Country
<oldpwd>
String type, it shall be the same as password specified for the facility from the ME user interface or
with command Change Password AT+CPWD.
<newpwd>
String type, it is the new password; maximum length of password can be determined with
<pwdlength>.
<pwdlength>
Integer type, max length of password.
Examples
AT+CPWD=?
+CPWD: ("AB",4),("AC",4),("AG",4),("AI",4),("AO",4),("IR",4),("OI",4),("OX",4),(
"SC",8),("P2",8)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
83
2017-12-25
Smart Machine Smart Decision
OK
5.5
AT+CCUG Closed user group
E
Description
FI
L
This command allows control of the Closed User Group supplementary service. Set command
enables the served subscriber to select a CUG index, to suppress the Outgoing Access (OA), and to
suppress the preferential CUG.
NOTE: This command not supported in CDMA/HDR mode.
3GPP TS 27.007
TI
YES
References
AL
SIM PIN
Responses
OK
ERROR
Responses
+CCUG: <n>,<index>,<info>
N
OK
FI
Read Command
AT+CCUG?
D
Test Command
AT+CCUG=?
EN
Syntax
O
ERROR
+CME ERROR: <err>
Responses
OK
M
C
Write Command
AT+CCUG=
<n>[,<index>[,<info>]]
+CME ERROR: <err>
Responses
Set default value:
OK
M
C
O
Execution Command
AT+CCUG
ERROR
Defined values
SI
<n>
0 – disable CUG temporary mode
1 – enable CUG temporary mode
<index>
0...9 – CUG index
10 – no index (preferred CUG taken from subscriber data)
<info>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
84
2017-12-25
Smart Machine Smart Decision
0
1
2
3
– no information
– suppress OA
– suppress preferential CUG
– suppress OA and preferential CUG
E
Examples
AT+CUSD
Unstructured supplementary service data
AL
5.6
FI
L
AT+CCUG?
+CCUG: 0,0,0
OK
TI
Description
YES
References
3GPP TS 27.007
Test Command
AT+CUSD=?
C
O
Syntax
N
SIM PIN
FI
D
EN
This command allows control of the Unstructured Supplementary Service Data (USSD). Both
network and mobile initiated operations are supported. Parameter <n> is used to disable/enable the
presentation of an unsolicited result code (USSD response from the network, or network initiated
operation) +CUSD: <m>[,<str>,<dcs>] to the TE. In addition, value <n>=2 is used to cancel an
ongoing USSD session.
NOTE: This command not supported in CDMA/HDR mode.
Responses
+CUSD: (list of supported <n>s)
M
OK
O
Read Command
AT+CUSD?
SI
M
C
Write Command
AT+CUSD=
<n>[,<str>[,<dcs>]]
Execution Command
AT+CUSD
Responses
+CUSD: <n>
OK
Responses
OK
ERROR
+CME ERROR: <err>
Responses
Set default value (<n>=0):
OK
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
85
2017-12-25
Smart Machine Smart Decision
<n>
EN
TI
AL
FI
L
E
0 – disable the result code presentation in the TA
1 – enable the result code presentation in the TA
2 – cancel session (not applicable to read command response)
<str>
String type USSD-string.
<dcs>
Cell Broadcast Data Coding Scheme in integer format (default 0).
<m>
0 – no further user action required (network initiated USSD-Notify, or no further
information needed after mobile initiated operation)
1 – further user action required (network initiated USSD-Request, or further information
needed after mobile initiated operation)
2 – USSD terminated by network
4 – operation not supported
5 – network time out
Examples
FI
N
O
AT+CAOC Advice of charge
C
5.7
D
AT+CUSD?
+CUSD: 1
OK
AT+CUSD=0
OK
Description
SI
M
C
O
M
This command refers to Advice of Charge supplementary service that enables subscriber to get
information about the cost of calls. With <mode>=0, the execute command returns the current call
meter value from the ME.
This command also includes the possibility to enable an unsolicited event reporting of the CCM
information. The unsolicited result code +CCCM: <ccm> is sent when the CCM value changes, but
not more that every 10 seconds. Deactivation of the unsolicited event reporting is made with the
same command.
NOTE: This command not supported in CDMA/HDR mode.
SIM PIN
YES
References
3GPP TS 27.007
Syntax
Test Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
86
2017-12-25
Smart Machine Smart Decision
AT+CAOC=?
+CAOC: (list of supported <mode>s)
OK
ERROR
Read Command
AT+CAOC?
Responses
+CAOC: <mode>
E
OK
FI
L
ERROR
+CME ERROR: <err>
Responses
+CAOC: <ccm>
AL
Write Command
AT+CAOC=<mode>
OK
ERROR
EN
+CME ERROR: <err>
TI
OK
Responses
Set default value (<mode>=1):
OK
ERROR
FI
D
Execution Command
AT+ CAOC
N
Defined values
O
M
C
O
<mode>
0 – query CCM value
1 – deactivate the unsolicited reporting of CCM value
2 – activate the unsolicited reporting of CCM value
<ccm>
String type, three bytes of the current call meter value in hexadecimal format (e.g. "00001E"
indicates decimal value 30), value is in home units and bytes are similarly coded as ACMmax value
in the SIM.
C
Examples
SI
M
AT+CAOC=0
+CAOC: "000000"
OK
5.8
AT+CSSN Supplementary service notifications
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
87
2017-12-25
Smart Machine Smart Decision
3GPP TS 27.007
EN
YES
References
TI
SIM PIN
AL
FI
L
E
This command refers to supplementary service related network initiated notifications. The set
command enables/disables the presentation of notification result codes from TA to TE.
When <n>=1 and a supplementary service notification is received after a mobile originated call
setup, intermediate result code +CSSI: <code1>[,<index>] is sent to TE before any other MO call
setup result codes presented in the present document. When several different <code1>s are received
from the network, each of them shall have its own +CSSI result code.
When <m>=1 and a supplementary service notification is received during a mobile terminated call
setup or during a call, or when a forward check supplementary service notification is received,
unsolicited result code +CSSU: <code2>[,<index>[,<number>,<type>[,<subaddr>,<satype>]]] is
sent to TE. In case of MT call setup, result code is sent after every +CLIP result code (refer
command "Calling line identification presentation +CLIP") and when several different <code2>s
are received from the network, each of them shall have its own +CSSU result code.
NOTE: This command not supported in CDMA/HDR mode.
Syntax
Responses
+CSSN: (list of supported <n>s),(list of supported <m>s)
OK
FI
D
Test Command
AT+CSSN=?
N
ERROR
Responses
+CSSN: <n>,<m>
O
Read Command
AT+CSSN?
C
OK
ERROR
Responses
OK
ERROR
+CME ERROR: <err>
C
O
M
Write Command
AT+CSSN=<n>[,<m>]
M
Defined values
SI
<n>
Parameter sets/shows the +CSSI result code presentation status in the TA:
0 – disable
1 – enable
<m>
Parameter sets/shows the +CSSU result code presentation status in the TA:
0 – disable
1 – enable
SIM7500_SIM7600 Series_AT Command Manual_V1.07
88
2017-12-25
Smart Machine Smart Decision
N
FI
D
EN
TI
AL
FI
L
E
<code1>
0 – unconditional call forwarding is active
1 – some of the conditional call forwarding are active
2 – call has been forwarded
3 – call is waiting
5 – outgoing calls are barred
<index>
Refer "Closed user group +CCUG".
<code2>
0 – this is a forwarded call (MT call setup)
2 – call has been put on hold (during a voice call)
3 – call has been retrieved (during a voice call)
5 – call on hold has been released (this is not a SS notification) (during a voice call)
<number>
String type phone number of format specified by <type>.
<type>
Type of address octet in integer format; default 145 when dialing string includes international
access code character "+", otherwise 129.
<subaddr>
String type sub address of format specified by <satype>.
<satype>
Type of sub address octet in integer format, default 128.
C
AT+CPOL Preferred operator list
C
5.9
O
M
AT+CSSN=1,1
OK
AT+CSSN?
+CSSN: 1,1
OK
O
Examples
M
Description
SI
This command is used to edit the SIM preferred list of networks.
SIM PIN
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+CPOL=?
Responses
+CPOL: (list of supported <index>s), (list of supported <format>s)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
89
2017-12-25
Smart Machine Smart Decision
OK
ERROR
Read Command
AT+CPOL?
Responses
[+CPOL:<index1>,<format>,<oper1>[<GSM_AcT1>,<GSM_Com
pact_AcT1>,<UTRAN_AcT1>,<LTE_AcT1>][<CR><LF>
FI
L
E
+CPOL:
<index2>,<format>,<oper2>[,<GSM_AcT1>,<GSM_Compact_Ac
T1>,<UTRAN_AcT1>,<LTE_AcT1>]
[...]]]
OK
ERROR
FI
D
EN
+CME ERROR: <err>
TI
Responses
OK
N
Write Command
AT+CPOL=<index>
[,<format>[,<oper>][,<GSM
_AcT1>,<GSM_Compact_A
cT1>,<UTRAN_AcT1>,<LT
E_AcT1> ]]
NOTE: If using USIM card,
the last four parameters must
set.
AL
ERROR
O
Defined values
SI
M
C
O
M
C
<index>
Integer type, the order number of operator in the SIM preferred operator list.
If only input <index>, command will delete the value indicate by <index>.
<format>
0 – long format alphanumeric <oper>
1 – short format alphanumeric <oper>
2 – numeric <oper>
<operX>
String type.
<GSM_AcTn>
GSM access technology:
0 – access technology not selected
1 – access technology selected
<GSM_Compact_AcTn>
GSM compact access technology:
0 – access technology not selected
1 – access technology selected
<UTRA_AcTn>
UTRA access technology:
SIM7500_SIM7600 Series_AT Command Manual_V1.07
90
2017-12-25
Smart Machine Smart Decision
E
0 – access technology not selected
1 – access technology selected
<LTE_AcTn>
LTE access technology:
0 – access technology not selected
1 – access technology selected
FI
L
Examples
TI
AT+COPN Read operator names
D
Description
EN
5.10
AL
AT+CPOL?
+CPOL: 1,2,"46001",0,0,1,0
OK
AT+CPOL=?
+CPOL: (1-8),(0-2)
OK
3GPP TS 27.007
Syntax
M
Test Command
AT+COPN=?
C
O
YES
References
N
SIM PIN
FI
This command is used to return the list of operator names from the ME. Each operator code
<numericX> that has an alphanumeric equivalent <alphaX> in the ME memory shall be returned.
SI
M
C
O
Write Command
AT+COPN
Responses
OK
ERROR
Responses
+COPN:<numeric1>,<alpha1>[<CR><LF>
+COPN: <numeric2>,<alpha2>
[...]]
OK
ERROR
+CME ERROR: <err>
Defined values
<numericX>
String type, operator in numeric format (see AT+COPS).
SIM7500_SIM7600 Series_AT Command Manual_V1.07
91
2017-12-25
Smart Machine Smart Decision
<alphaX>
String type, operator in long alphanumeric format (see AT+COPS).
Examples
FI
L
AT+CNMP Preferred mode selection
TI
Description
AL
5.11
E
AT+COPN
+COPN: "46000","China Mobile Com"
+COPN: "46001"," China Unicom"
……
OK
SIM PIN
References
Vendor
D
NO
EN
This command is used to select or set the state of the mode preference.
FI
Syntax
Responses
+CNMP: (list of supported <mode>s)
N
Test Command
AT+CNMP=?
Responses
+CNMP: <mode>
C
Read Command
AT+CNMP?
O
OK
OK
Responses
OK
If <mode> not supported by module, this command will return
ERROR.
ERROR
M
C
O
M
Write Command
AT+CNMP=<mode>
Defined values
SI
<mode>
2
– Automatic
13 – GSM Only
14 – WCDMA Only
38 – LTE Only
59 – TDS-CDMA Only(must use after AT+NETMODE, please refer to AT+NETMODE
command description)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
92
2017-12-25
Smart Machine Smart Decision
CDMA Only
EVDO Only
GSM+WCDMA Only
CDMA+EVDO Only
Any modes but LTE
GSM+TDSCDMA Only
GSM+WCDMA+TDSCDMA Only
CDMA+EVDO+GSM+WCDMA+TDSCDMA Only
GSM+WDMA+LTE Only
WDMA+LTE Only
AL
Examples
EN
TI
AT+CNMP=13
OK
AT+CNMP?
+CNMP: 2
OK
D
AT+CNBP Preferred band selection
FI
5.12
E
–
–
–
–
–
–
–
–
–
–
FI
L
9
10
19
22
48
60
63
67
39
54
N
Description
NO
References
Vendor
C
SIM PIN
O
This command is used to select or set the state of the band preference.
M
Syntax
C
O
Test Command
AT+CNBP?
OK
Responses
OK
ERROR
SI
M
Write Command
AT+CNBP=<mode>[,<lte_
mode>][,<tds_mode>]
Responses
+CNBP: <mode>[,<lte_mode>][,<tds_mode>]
Defined values
<mode>
64bit number, the value is “1” << “<pos>”, then or by bit.
Some special mode value declared below:
0x40000000
BAND_PREF_NO_CHANGE
<pos>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
93
2017-12-25
Smart Machine Smart Decision
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
Value:
0xFFFFFFFF7FFFFFFF
Any (any value)
7
GSM_DCS_1800
8
GSM_EGSM_900
9
GSM_PGSM_900
16
GSM_450
17
GSM_480
18
GSM_750
19
GSM_850
20
GSM_RGSM_900
21
GSM_PCS_1900
22
WCDMA_IMT_2000
23
WCDMA_PCS_1900
24
WCDMA_III_1700
25
WCDMA_IV_1700
26
WCDMA_850
27
WCDMA_800
48
WCDMA_VII_2600
49
WCDMA_VIII_900
50
WCDMA_IX_1700
<lte_mode>
64bit number, the value is “1” << “<lte_pos>”, then or by bit.
NOTE: FDD(band1 ~ band32), TDD(band33 ~ band42)
<lte_pos>
Value:
0x000007FF3FDF3FFF
Any (any value)
0
EUTRAN_BAND1(UL:1920-1980; DL:2110-2170)
1
EUTRAN_BAND2(UL:1850-1910; DL:1930-1990)
2
EUTRAN_BAND3(UL:1710-1785; DL:1805-1880)
3
EUTRAN_BAND4(UL:1710-1755; DL:2110-2155)
4
EUTRAN_BAND5(UL: 824-849; DL: 869-894)
5
EUTRAN_BAND6(UL: 830-840; DL: 875-885)
6
EUTRAN_BAND7(UL:2500-2570; DL:2620-2690)
7
EUTRAN_BAND8(UL: 880-915; DL: 925-960)
8
EUTRAN_BAND9(UL:1749.9-1784.9; DL:1844.9-1879.9)
9
EUTRAN_BAND10(UL:1710-1770; DL:2110-2170)
10
EUTRAN_BAND11(UL:1427.9-1452.9; DL:1475.9-1500.9)
11
EUTRAN_BAND12(UL:698-716; DL:728-746)
12
EUTRAN_BAND13(UL: 777-787; DL: 746-756)
13
EUTRAN_BAND14(UL: 788-798; DL: 758-768)
16
EUTRAN_BAND17(UL: 704-716; DL: 734-746)
17
EUTRAN_BAND18(UL: 815-830; DL: 860-875)
18
EUTRAN_BAND19(UL: 830-845; DL: 875-890)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
94
2017-12-25
Smart Machine Smart Decision
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
19
EUTRAN_BAND20(UL: 832-862; DL: 791-821)
20
EUTRAN_BAND21(UL: 1447.9-1462.9; DL: 1495.9-1510.9)
22
EUTRAN_BAND23(UL: 2000-2020; DL: 2180-2200)
23
EUTRAN_BAND24(UL: 1626.5-1660.5; DL: 1525 -1559)
24
EUTRAN_BAND25(UL: 1850-1915; DL: 1930 -1995)
25
EUTRAN_BAND26(UL: 814-849; DL: 859 -894)
26
EUTRAN_BAND27(UL: 807.5-824; DL: 852 -869)
27
EUTRAN_BAND28(703-748; DL: 758-803)
28
EUTRAN_BAND29(UL:1850-1910 or 1710-1755;
DL:716-728)
29
EUTRAN_BAND30(UL: 2305-2315 ; DL: 2350 - 2360)
32
EUTRAN_BAND33(UL: 1900-1920; DL: 1900-1920)
33
EUTRAN_BAND34(UL: 2010-2025; DL: 2010-2025)
34
EUTRAN_BAND35(UL: 1850-1910; DL: 1850-1910)
35
EUTRAN_BAND36(UL: 1930-1990; DL: 1930-1990)
36
EUTRAN_BAND37(UL: 1910-1930; DL: 1910-1930)
37
EUTRAN_BAND38(UL: 2570-2620; DL: 2570-2620)
38
EUTRAN_BAND39(UL: 1880-1920; DL: 1880-1920)
39
EUTRAN_BAND40(UL: 2300-2400; DL: 2300-2400)
40
EUTRAN_BAND41(UL: 2496-2690; DL: 2496-2690)
41
EUTRAN_BAND42(UL: 3400-3600; DL: 3400-3600)
42
EUTRAN_BAND43(UL: 3600-3800; DL: 3600-3800)
<tds_mode>
64bit number, the value is “1” << “<tds_pos>”, then or by bit.
<tds_pos>
Value:
0x000000000000003F
Any (any value)
0
TDS Band A (1900-1920 MHz, 2010-2020 MHz)
1
TDS Band B (1850-1910 MHz, 1930-1990 MHz)
2
TDS Band C (1910-1930 MHz)
3
TDS Band D (2570-2620 MHz)
4
TDS Band E (2300-2400 MHz)
5
TDS Band F (1880-1920 MHz)
<term_mode>
0 – term permanent
1 – term until a power cycle
Examples
AT+CNBP=0x000700000FFF0380
OK
AT+CNBP?
+CNBP: 0x0000000000400003,0x000007FF03DF3FFF,0x000000000000003F
SIM7500_SIM7600 Series_AT Command Manual_V1.07
95
2017-12-25
Smart Machine Smart Decision
OK
5.13
AT+CNAOP Acquisitions order preference
Description
NO
References
FI
L
SIM PIN
E
This command is used to reset the state of acquisitions order preference.
Vendor
AL
Syntax
Responses
+CNAOP: <mode>[,<sys_mode1>,[<sys_mode2>[,<sys_mode3>[,
<sys_mode4>[,<sys_mode5>[,<sys_mode6>]]]]]]
TI
Read Command
AT+CNAOP?
N
FI
ERROR
D
Responses
OK
O
Write Command
AT+CNAOP=<mode>[,<sys
_mode1>[,<sys_mode2>[,<sy
s_mode3>[,<sys_mode4>[,<s
ys_mode5>[,<sys_mode6>]]]
]]]
EN
OK
C
Defined values
SI
M
C
O
M
<mode>
7 – Acquistion by priority order list <sys_moden>s.
<sys_moden>
sys_mode values:
2 – CDMA
3 – GSM
4 – HDR
5 – WCDMA
9 – LTE
11 – TDSCDMA
Examples
AT+CNAOP=7,9,5,3,11,2,4
OK
AT+CNAOP?
+CNAOP: 7,9,5,3,11,2,4
SIM7500_SIM7600 Series_AT Command Manual_V1.07
96
2017-12-25
Smart Machine Smart Decision
OK
5.14
AT+CPSI Inquiring UE system information
Description
NO
References
FI
L
SIM PIN
E
This command is used to return the UE system information.
Vendor
Responses
+CPSI: (scope of <time>)
Read Command
EN
OK
TI
Test Command
AT+CPSI=?
AL
Syntax
Responses
If camping on a cdma/evdo cell:
N
FI
D
+CPSI: CDMA,<Operation Mode>[,<MCC>-<MNC>,<CDMA ch
num>,<CDMA pilot PN>,<CDMA RX Chain 0 AGC>,<CDMA
RX Chain 1 AGC>,<CDMA Chain 0 LNA>,<CDMA Chain 1
LNA>,<CDMA
TX
AGC>,<SID>,<NID>,<CDMA
EC/IO>,<BID>]
C
O
+CPSI: EVDO,<Operation Mode>[,<MCC>-<MNC>,<EVDO ch
num>,<EVDO RX Chain 0 AGC>,<EVDO RX Chain 1 AGC>,<
EVDO TX AGC>,<EVDO Serving PN>,<EVDO Rel0
SCI>,<EVDO RelA SCI>,<EVDO EC/IO>]
OK
SI
M
C
O
M
AT+CPSI?
If camping on a gsm cell:
+CPSI:<System Mode>,<Operation Mode>,<MCC>-<MNC>,<L
AC>,<Cell ID>,<Absolute RF Ch Num>,<RxLev>,
<Track LO Adjust>,<C1-C2>
OK
If camping on a wcdma cell:
+CPSI: <System Mode>,<Operation Mode>,<MCC>-<MNC>,<
LAC>,<Cell ID>,<Frequency Band>,<PSC>,<Freq>,<SSC>,<EC
/IO>,<RSCP>,<Qual>,<RxLev>,<TXPWR>
OK
If camping on a tds-cdma cell:
+CPSI: <System Mode>,<Operation Mode>,<MCC>-<MNC>,<
LAC>,<Cell ID>,<Frequency Band>,<Uarfcn>,<Cpid>
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
97
2017-12-25
Smart Machine Smart Decision
If camping on a lte cell:
+CPSI: <System Mode>,<Operation Mode>[,<MCC>-<MNC>,<
TAC>,<SCellID>,<PCellID>,<Frequency Band>,<earfcn>,<dlb
w>,<ulbw>,<RSRQ>,<RSRP>,<RSSI>,<RSSNR>]
OK
E
If camping on a cdma/evdo cell:
AL
FI
L
+CPSI: CDMA,<Operation Mode>[,<MCC>-<MNC>,<CDMA ch
num>,<CDMA pilot PN>,<CDMA RX Chain 0 AGC>,<CDMA
RX Chain 1 AGC>,<CDMA Chain 0 LNA>,<CDMA Chain 1
LNA>,<CDMA
TX
AGC>,<SID>,<NID>,<CDMA
EC/IO>,<BID>]
TI
+CPSI: EVDO,<Operation Mode>[,<MCC>-<MNC>,<EVDO ch
num>,<EVDO RX Chain 0 AGC>,<EVDO RX Chain 1 AGC>,<
EVDO TX AGC>,<EVDO Serving PN>,<EVDO Rel0
SCI>,<EVDO RelA SCI>,<EVDO EC/IO>]
EN
OK
If camping on a cdma/ehrpd cell:
N
FI
D
+CPSI: CDMA,<Operation Mode>[,<MCC>-<MNC>,<CDMA ch
num>,<CDMA pilot PN>,<CDMA RX Chain 0 AGC>,<CDMA
RX Chain 1 AGC>,<CDMA Chain 0 LNA>,<CDMA Chain 1
LNA>,<CDMA
TX
AGC>,<SID>,<NID>,<CDMA
EC/IO>,<BID>]
C
O
+CPSI: eHRPD,<Operation Mode>[,<MCC>-<MNC>,<EVDO ch
num>,<EVDO RX Chain 0 AGC>,<EVDO RX Chain 1 AGC>,<
EVDO TX AGC>,<EVDO Serving PN>,<EVDO Rel0
SCI>,<EVDO RelA SCI>,<EVDO EC/IO>]
SI
M
C
O
M
OK
If camping on 1xlte cell:
+CPSI: CDMA,<Operation Mode>[,<MCC>-<MNC>,<CDMA ch
num>,<CDMA pilot PN>,<CDMA RX Chain 0 AGC>,<CDMA
RX Chain 1 AGC>,<CDMA Chain 0 LNA>,<CDMA Chain 1
LNA>,<CDMA
TX
AGC>,<SID>,<NID>,<CDMA
EC/IO>,<BID>]
+CPSI: LTE,<Operation Mode>[,<MCC>-<MNC>,<TAC>,<SCe
llID>,<PCellID>,<Frequency Band>,<earfcn>,<dlbw>,<ulbw>,<R
SRQ>,<RSRP>,<RSSI>,<RSSNR>]
OK
If no service:
+CPSI: NO SERVICE, Online
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
98
2017-12-25
Smart Machine Smart Decision
Write Command
AT+CPSI=<time>
Responses
OK
ERROR
E
Defined values
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
<time>
The range is 0-255, unit is second, after set <time> will report the system information every the
seconds.
<System Mode>
System mode, values: “NO SERVICE”, “GSM”, “WCDMA”, “LTE”, “TDS”…
If module in LIMITED SERVICE state and +CNLSA command is set to 1, the system mode will
display as “GSM-LIMITED”, “WCDMA-LIMITED”…
<Operation Mode>
UE operation mode, values: “Unknown”, “Online”, “Offline”, “Factory Test Mode”, “Reset”, “Low
Power Mode”.
<MCC>
Mobile Country Code (first part of the PLMN code)
<MNC>
Mobile Network Code (second part of the PLMN code)
<LAC>
Location Area Code (hexadecimal digits)
<Cell ID>
Service-cell Identify.
<Absolute RF Ch Num>
AFRCN for service-cell.
<Track LO Adjust>
Track LO Adjust
<C1>
Coefficient for base station selection
<C2>
Coefficient for Cell re-selection
<Frequency Band>
Frequency Band of active set
<PSC>
Primary synchronization code of active set.
<Freq>
Downlink frequency of active set.
<SSC>
Secondary synchronization code of active set
<EC/IO>
Ec/Io value
<RSCP>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
99
2017-12-25
Examples
FI
L
M
C
O
N
FI
D
EN
TI
AL
Received Signal Code Power
<Qual>
Quality value for base station selection
<RxLev>
RX level value for base station selection
<TXPWR>
UE TX power in dBm. If no TX, the value is 500.
<Cpid>
Cell Parameter ID
<TAC>
Tracing Area Code
<PCellID>
Physical Cell ID
<earfcn>
E-UTRA absolute radio frequency channel number for searching LTE cells
<dlbw>
Transmission bandwidth configuration of the serving cell on the downlink
<ulbw>
Transmission bandwidth configuration of the serving cell on the uplink
<RSRP>
Current reference signal received power in -1/10 dBm. Available for LTE
<RSRQ>
Current reference signal receive quality as measured by L1.
<RSSNR>
Average reference signal signal-to-noise ratio of the serving cell
<BID>
Base ID
E
Smart Machine Smart Decision
SI
M
C
O
AT+CPSI?
+CPSI: GSM,Online,460-00,0x182d,12401,27 EGSM 900,-64,2110,42-42
OK
AT+CPSI?
+CPSI: WCDMA,Online,460-01,0xA809,11122855,WCDMA IMT 2000,279,10663,0,1.5,62,33,
52,500
OK
AT+CPSI=?
+CPSI: (0-255)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
100
2017-12-25
Smart Machine Smart Decision
5.15
AT+CNSMOD Show network system mode
Description
This command is used to return the current network system mode.
Vendor
FI
L
NO
References
E
SIM PIN
Test Command
AT+CNSMOD=?
Responses
+CNSMOD: (list of supported <n>s)
Responses
+CNSMOD: <n>,<stat>
EN
Read Command
AT+CNSMOD?
TI
OK
AL
Syntax
OK
ERROR
Responses
OK
FI
Write Command
AT+CNSMOD=<n>
D
+CME ERROR: <err>
N
ERROR
<n>
C
Defined values
O
+CME ERROR: <err>
SI
M
C
O
M
0 – disable auto report the network system mode information
1 – auto report the network system mode information, command: +CNSMOD:<stat>
<stat>
0 – no service
1 – GSM
2 – GPRS
3 – EGPRS (EDGE)
4 – WCDMA
5 – HSDPA only(WCDMA)
6 – HSUPA only(WCDMA)
7 – HSPA (HSDPA and HSUPA, WCDMA)
8 – LTE
9 – TDS-CDMA
10 – TDS-HSDPA only
11 – TDS- HSUPA only
SIM7500_SIM7600 Series_AT Command Manual_V1.07
101
2017-12-25
Smart Machine Smart Decision
TDS- HSPA (HSDPA and HSUPA)
CDMA
EVDO
HYBRID (CDMA and EVDO)
1XLTE(CDMA and LTE)
eHRPD
HYBRID(CDMA and eHRPD)
E
–
–
–
–
–
–
–
FI
L
12
13
14
15
16
23
24
AT+CNSMOD?
+CNSMOD: 0,2
OK
TI
AT+CEREG EPS network registration status
EN
5.16
AL
Examples
Description
M
C
O
N
FI
D
The set command controls the presentation of an unsolicited result code +CEREG: <stat> when
<n>=1 and there is a change in the MT's EPS network registration status in E-UTRAN, or
unsolicited result code +CEREG: <stat>[,<tac>,<ci>[,<AcT>]] when <n>=2 and there is a change
of the network cell in E-UTRAN; in this latest case <AcT>, <tac> and <ci> are sent only if
available.
NOTE 1: If the EPS MT in GERAN/UTRAN/E-UTRAN also supports circuit mode services and/or
GPRS services, the +CREG command and +CREG: result codes and/or the +CGREG command
and +CGREG: result codes apply to the registration status and location information for those
services.
The read command returns the status of result code presentation and an integer <stat> which shows
whether the network has currently indicated the registration of the MT. Location information
elements <tac>, <ci> and <AcT>, if available, are returned only when <n>=2 and MT is registered
in the network.
References
O
SIM PIN
C
NO
3GPP TS 24.008 [8]
M
Syntax
SI
Test Command
AT+CEREG=?
Responses
+CEREG: (list of supported <n>s)
OK
ERROR
Read Command
AT+CEREG?
Responses
+CEREG: <n>,<stat>[,<tac>,<ci>[,<AcT>]]
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
102
2017-12-25
Smart Machine Smart Decision
ERROR
Write Command
AT+CEREG=[<n>]
Responses
OK
ERROR
FI
L
Responses
Set default value(<n>=0):
OK
ERROR
AL
Execution Command
AT+CEREG
E
+CME ERROR: <err>
Defined values
TI
<n>
O
M
C
O
N
FI
D
EN
0 – disable network registration unsolicited result code
1 – enable network registration unsolicited result code +CEREG: <stat>
2 – enable network registration and location information unsolicited result code
+CEREG: <stat>[,<tac>,<ci>[,<AcT>]]
<stat>
0 – not registered, MT is not currently searching an operator to register to
1 – registered, home network
2 – not registered, but MT is currently trying to attach or searching an operator to register to
3 – registration denied
4 – unknown (e.g. out of E-UTRAN coverage)
5 – registered, roaming
6 – registered for "SMS only", home network (not applicable)
7 – registered for "SMS only", roaming (not applicable)
8 – attached for emergency bearer services only (See NOTE 2)
<tac>
string type; two byte tracking area code in hexadecimal format (e.g. "00C3" equals 195 in decimal)
<ci>
C
string type; four byte E-UTRAN cell identify in hexadecimal format
SI
M
<AcT>
A numberic parameter that indicates the access technology of serving cell
0 GSM (not applicable)
1 GSM Compact (not applicable)
2 UTRAN (not applicable)
3 GSM w/EGPRS (see NOTE 3) (not applicable)
4 UTRAN w/HSDPA (see NOTE 4) (not applicable)
5 UTRAN w/HSUPA (see NOTE 4) (not applicable)
6 UTRAN w/HSDPA and HSUPA (see NOTE 4) (not applicable)
7 E-UTRAN
SIM7500_SIM7600 Series_AT Command Manual_V1.07
103
2017-12-25
Smart Machine Smart Decision
Examples
AT+CEREG?
+ CEREG: 0,4
OK
E
AT+CTZU Automatic time and time zone update
FI
L
5.17
Description
This command is used to enable and disable automatic time and time zone update via NITZ
3GPP TS 27.007
TI
YES
References
AL
SIM PIN
EN
Syntax
Responses
+CTZU: (list of supported <on/off>s)
OK
Read Command
AT+CTZU?
Responses
+CTZU: < on/off >
OK
Write Command
AT+CTZU=< on/off >
Responses
OK
O
N
FI
D
Test Command
AT+CTZU=?
Defined values
C
ERROR
SI
M
C
O
M
<on/off>
Integer type value indicating:
0 – Disable automatic time zone update via NITZ (default).
1 – Enable automatic time zone update via NITZ.
NOTE: 1. The value of < on/off > is nonvolatile, and factory value is 0.
2. For automatic time and time zone update is enabled (+CTZU=1):
If time zone is only received from network and it isn’t equal to local time zone
(AT+CCLK), time zone is updated automatically, and real time clock is updated based
on local time and the difference between time zone from network and local time zone
(Local time zone must be valid).
If Universal Time and time zone are received from network, both time zone and real
time clock is updated automatically, and real time clock is based on Universal Time and
time zone from network.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
104
2017-12-25
Smart Machine Smart Decision
Examples
FI
L
5.18
E
AT+CTZU?
+CTZU: 0
OK
AT+CTZU=1
OK
AT+CTZR Time and time zone reporting
AL
Description
SIM PIN
References
3GPP TS 27.007
D
YES
EN
TI
This command is used to enable and disable the time zone change event reporting. If the reporting
is enabled the MT returns the unsolicited result code +CTZV: <tz>[,<time>][,<dst>]whenever the
time zone is changed.
NOTE: The time zone reporting is not affected by the Automatic Time and Time Zone command
AT+CTZU.
FI
Syntax
O
C
Responses
+CTZR: < on/off >
OK
Responses
OK
ERROR
M
Write Command
AT+CTZR=< on/off >
O
Read Command
AT+CTZR?
Responses
+CTZR: (list of supported < on/off >s)
OK
N
Test Command
AT+CTZR=?
Responses
Set default value:
OK
SI
M
C
Execution Command
AT+CTZR
Defined values
<on/off>
Integer type value indicating:
0 – Disable time zone change event reporting (default).
1 – Enable time zone change event reporting.
+CTZV: <tz>[,<time>][,<dst>]
Unsolicited result code when time zone received from network isn’t equal to local time zone, and if
SIM7500_SIM7600 Series_AT Command Manual_V1.07
105
2017-12-25
Smart Machine Smart Decision
E
the informations from network don’t include date and time, time zone will be only reported, and if
network daylight saving time is present, it is also reported. For example:
+CTZV: 32 (Only report time zone)
+CTZV: 32,1 (Report time zone and network daylight saving time)
+CTZV: 32,08/12/09,17:00:00 (Report time and time zone)
+CTZV: 32,08/12/09,17:00:00,1 (Report time, time zone and daylight saving time)
EN
TI
AL
FI
L
For more detailed informations about time and time zone, please refer 3GPP TS 24.008.
<tz>
Local time zone received from network.
<time> Universal time received from network, and the format is “yy/MM/dd,hh:mm:ss”,
where characters indicate year (two last digits), month, day, hour, minutes and
seconds.
<dst> Network daylight saving time, and if it is received from network, it indicates the
value that has been used to adjust the local time zone. The values as following:
0 – No adjustment for Daylight Saving Time.
1 – +1 hour adjustment for Daylight Saving Time.
2 – +2 hours adjustment for Daylight Saving Time.
NOTE: Herein, <time> is Universal Time or NITZ time, but not local time.
D
Examples
N
O
C
5.19
FI
AT+CTZR?
+CTZR: 0
OK
AT+CTZR=1
OK
AT+NETMODE WCDMA & TDSCDMA mode select
M
Description
M
C
O
This command is used to select WCDMA mode or TDSCDMA mode.
NOTE: The command will take effect after reboot system next time if you modify the current
mode. The WCDMA and TDSCDMA can not work at the same time. Only for 7500 and
7600 module.
SIM PIN
SI
NO
References
Vendor
Syntax
Test Command
AT+NETMODE=?
Responses
+NETMODE: (list of supported <netmode>s)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
106
2017-12-25
Smart Machine Smart Decision
Read Command
AT+NETMODE?
Responses
+NETMODE: <netmode>
OK
Write Command
AT+NETMODE=<netmode
>
Responses
OK
FI
L
E
ERROR
Defined values
TI
AL
<netmode>
Integer type value indicating:
1 – TDSCDMA mode.
2 – WCDMA mode(default).
EN
Examples
SI
M
C
O
M
C
O
N
FI
D
AT+NETMODE?
+NETMODE: 2
OK
AT+NETMODE=1
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
107
2017-12-25
Smart Machine Smart Decision
6.1
AT Commands for Call Control
AT+CVHU
Voice hang up control
E
6
FI
L
Description
SIM PIN
References
3GPP TS 27.007
TI
NO
AL
Write command selects whether ATH or “drop DTR” shall cause a voice connection to be
disconnected or not. By voice connection is also meant alternating mode calls that are currently in
voice mode.
EN
Syntax
Responses
+CVHU: (list of supported <mode>s)
OK
Read Command
AT+CVHU?
Responses
+CVHU: <mode>
OK
Write Command
AT+CVHU=<mode>
Responses
OK
C
O
N
FI
D
Test Command
AT+CVHU=?
ERROR
Responses
Set default value:
OK
O
M
Execution Command
AT+CVHU
C
Defined values
SI
M
<mode>
0 – “Drop DTR” ignored but OK response given. ATH disconnects.
1 – “Drop DTR” and ATH ignored but OK response given.
Examples
AT+CVHU=0
OK
AT+CVHU?
+CVHU: 0
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
108
2017-12-25
Smart Machine Smart Decision
6.2
AT+CHUP Hang up call
Description
NO
References
FI
L
SIM PIN
E
This command is used to cancel voice calls. If there is no call, it will do nothing but OK response is
given. After running AT+CHUP, multiple “VOICE CALL END: ” may be reported which relies on
how many calls exist before calling this command.
3GPP TS 27.007
Responses
OK
Execution Command
AT+CHUP
Responses
VOICE CALL: END: <time>
[…
VOICE CALL: END: <time>]
OK
FI
N
No call:
OK
D
EN
Test Command
AT+CHUP=?
TI
AL
Syntax
O
Defined values
Examples
M
C
<time>
Voice call connection time.
Format – HHMMSS (HH: hour, MM: minute, SS: second)
M
C
O
AT+CHUP
VOICE CALL:END: 000017
OK
AT+CBST Select bearer service type
SI
6.3
Description
Write command selects the bearer service <name> with data rate <speed>, and the connection
element <ce> to be used when data calls are originated. Values may also be used during mobile
terminated data call setup, especially in case of single numbering scheme calls.
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
109
2017-12-25
Smart Machine Smart Decision
YES
3GPP TS 27.007
Syntax
Responses
+CBST: (list of supported <speed>s), (list of supported <name>s),
(list of supported <ce>s)
OK
Responses
+CBST: <speed>,<name>,<ce>
OK
Responses
OK
Execution Command
AT+CBST
ERROR
Responses
Set default value:
OK
FI
–
autobauding(automatic selection of the speed; this setting is possible in case of 3.1
kHz modem and non-transparent service)
9600 bps (V.32)
9600 bps (V.34)
14400 bps(V.34)
28800 bps(V.34)
33600 bps(V.34)
9600 bps(V.120)
14400 bps(V.120)
28800 bps(V.120)
56000 bps(V.120)
9600 bps(V.110)
14400 bps(V.110)
28800 bps(V.110 or X.31 flag stuffing)
38400 bps(V.110 or X.31 flag stuffing)
56000 bps(V.110 or X.31 flag stuffing)
64000 bps(X.31 flag stuffing)
64000 bps(bit transparent)
64000 bps(multimedia)
N
<speed>
0
D
Defined values
TI
Write Command
AT+CBST=
<speed>[,<name>[,<ce>]]
EN
Read Command
AT+CBST?
AL
FI
L
E
Test Command
AT+CBST=?
SI
M
C
O
M
C
O
7
–
12 –
14 –
16 –
17 –
39 –
43 –
48 –
51 –
71 –
75 –
80 –
81 –
83 –
84 –
116 –
134 –
<name>
0 – Asynchronous modem
1 – Synchronous modem
SIM7500_SIM7600 Series_AT Command Manual_V1.07
110
2017-12-25
Smart Machine Smart Decision
E
4 – data circuit asynchronous (RDI)
<ce>
0 – transparent
1 – non-transparent
NOTE: If <speed> is set to 116 or 134, it is necessary that <name> is equal to 1 and <ce> is equal
to 0.
FI
L
Examples
Description
TI
AT+CRLP Radio link protocol
EN
6.4
AL
AT+CBST=0,0,1
OK
AT+CBST?
+CBST:0,0,1
OK
SIM PIN
3GPP TS 27.007
O
Syntax
References
M
YES
C
O
N
FI
D
Radio Link Protocol(RLP) parameters used when non-transparent data calls are originated may be
altered with write command.
Read command returns current settings for each supported RLP version <verX>. Only RLP
parameters applicable to the corresponding <verX> are returned.
Test command returns values supported by the TA as a compound value. If ME/TA supports several
RLP versions <verX>, the RLP parameter value ranges for each <verX> are returned in a separate
line.
SI
M
C
Test Command
AT+CRLP=?
Read Command
AT+CRLP?
Responses
+CRLP: (list of supported <iws>s), (list of supported <mws>s),
(list of supported <T1>s), (list of supported <N2>s) [,<ver1>
[,(list of supported <T4>s)]][<CR><LF>
+CRLP: (list of supported <iws>s), (list of supported <mws>s),
(list of supported <T1>s), (list of supported <N2>s) [,<ver2>
[,(list of supported <T4>s)]]
[...]]
OK
Responses
+CRLP: <iws>, <mws>, <T1>, <N2> [,<ver1> [, <T4>]][<CR>
<LF>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
111
2017-12-25
Smart Machine Smart Decision
Write Command
AT+CRLP=<iws>
[,<mws>[,<T1>[,<N2>
[,<ver>[,<T4>]]]]]
Responses
OK
Execution Command
AT+CRLP
Responses
OK
E
+CRLP:<iws>,<mws>,<T1>,<N2>[,<ver2>[,<T4>]]
[...]]
OK
FI
L
ERROR
AL
Defined values
C
O
N
FI
D
EN
TI
<ver>, <verX>
RLP version number in integer format, and it can be 0, 1 or 2; when version indication is not
present it shall equal 1.
<iws>
IWF to MS window size.
<mws>
MS to IWF window size.
<T1>
Acknowledgement timer.
<N2>
Retransmission attempts.
<T4>
Re-sequencing period in integer format.
NOTE: <T1> and <T4> are in units of 10 ms.
M
Examples
M
C
O
AT+CRLP?
+CRLP:61,61,48,6,0
+CRLP:61,61,48,6,1
+CRLP:240,240,52,6,2
OK
AT+CR Service reporting control
SI
6.5
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
112
2017-12-25
Smart Machine Smart Decision
Write command controls whether or not intermediate result code “+CR: <serv>” is returned from
the TA to the TE. If enabled, the intermediate result code is transmitted at the point during connect
negotiation at which the TA has determined which speed and quality of service will be used, before
any error control or data compression reports are transmitted, and before the intermediate result
code CONNECT is transmitted.
3GPP TS 27.007
FI
L
YES
References
E
SIM PIN
Responses
+CR: (list of supported <mode>s)
OK
Read Command
AT+CR?
Responses
+CR: <mode>
OK
Write Command
AT+CR=<mode>
Responses
OK
Execution Command
AT+CR
Responses
Set default value:
OK
N
FI
D
EN
TI
Test Command
AT+CR=?
AL
Syntax
O
Defined values
SI
M
C
O
M
C
<mode>
0 – disables reporting
1 – enables reporting
<serv>
ASYNC
asynchronous transparent
SYNC
synchronous transparent
REL ASYNC
asynchronous non-transparent
REL sync
synchronous non-transparent
GPRS [<L2P>]
GPRS
The optional <L2P> proposes a layer 2 protocol to use between the MT and the TE.
Examples
AT+CR?
+CR:0
OK
AT+CR=1
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
113
2017-12-25
Smart Machine Smart Decision
6.6
AT+CRC
Cellular result codes
Description
SIM PIN
References
3GPP TS 27.007
Syntax
Responses
+CRC: (list of supported <mode>s)
OK
Read Command
AT+CRC?
Responses
+CRC: <mode>
OK
Write Command
AT+CRC=<mode>
Responses
OK
Execution Command
AT+CRC
Responses
Set default value:
OK
EN
D
FI
N
O
C
Defined values
TI
Test Command
AT+CRC=?
AL
YES
FI
L
E
Write command controls whether or not the extended format of incoming call indication or GPRS
network request for PDP context activation is used. When enabled, an incoming call is indicated to
the TE with unsolicited result code “+CRING: <type>” instead of the normal RING.
Test command returns values supported by the TA as a compound value.
SI
M
C
O
M
<mode>
0 – disable extended format
1 – enable extended format
<type>
ASYNC
asynchronous transparent
SYNC
synchronous transparent
REL ASYNC
asynchronous non-transparent
REL SYNC
synchronous non-transparent
FAX
facsimile
VOICE
normal voice
VOICE/XXX
voice followed by data(XXX is ASYNC, SYNC, REL ASYNC or REL
SYNC)
ALT VOICE/XXX alternating voice/data, voice first
ALT XXX/VOICE alternating voice/data, data first
ALT FAX/VOICE alternating voice/fax, fax first
SIM7500_SIM7600 Series_AT Command Manual_V1.07
114
2017-12-25
Smart Machine Smart Decision
GPRS
GPRS network request for PDP context activation
Examples
FI
L
AL
6.7
E
AT+CRC=1
OK
AT+CRC?
+CRC: 1
OK
AT+CLCC List current calls
TI
Description
SIM PIN
References
D
3GPP TS 27.007
FI
NO
EN
This command isused to return list of current calls of ME. If command succeeds but no calls are
available, no information response is sent to TE.
N
Syntax
C
M
Read Command
AT+CLCC?
Responses
+CLCC: (list of supported <n>s)
OK
O
Test Command
AT+CLCC=?
Write Command
O
AT+CLCC=<n>
SI
M
C
Execution Command
AT+CLCC
Responses
+CLCC: <n>
OK
Responses
OK
Responses
+CLCC:<id1>,<dir>,<stat>,<mode>,<mpty>[,<number>,<type>[,<
alpha>]][<CR><LF>
+CLCC:<id2>,<dir>,<stat>,<mode>,<mpty>[,<number>,<type>[,<
alpha>]]
[...]]
OK
ERROR
+CME ERROR: <err>
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
115
2017-12-25
Smart Machine Smart Decision
<n>
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
0 – Don’t report a list of current calls of ME automatically when the current call status
changes.
1 – Report a list of current calls of ME automatically when the current call status changes.
<idX>
Integer type, call identification number, this number can be used in +CHLD command operations.
<dir>
0 – mobile originated (MO) call
1 – mobile terminated (MT) call
<stat>
State of the call:
0 – active
1 – held
2 – dialing (MO call)
3 – alerting (MO call)
4 – incoming (MT call)
5 – waiting (MT call)
6 – disconnect
<mode>
bearer/teleservice:
0 – voice
1 – data
2 – fax
9 – unknown
<mpty>
0 – call is not one of multiparty (conference) call parties
1 – call is one of multiparty (conference) call parties
<number>
String type phone number in format specified by <type>.
<type>
Type of address octet in integer format;
128 – Restricted number type includes unknown type and format
145 – International number type
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
129 – Otherwise
<alpha>
String type alphanumeric representation of <number> corresponding to the entry found in
phonebook; used character set should be the one selected with command Select TE Character Set
AT+CSCS.
Examples
SIM7500_SIM7600 Series_AT Command Manual_V1.07
116
2017-12-25
Smart Machine Smart Decision
FI
L
AL
AT+CEER Extended error report
TI
6.8
E
ATD10011;
OK
AT+CLCC
+CLCC: 1,0,0,0,0,"10011",129,"sm"
OK
RING (with incoming call)
AT+CLCC
+CLCC: 1,1,4,0,0,"02152063113",128,"gongsi"
OK
EN
Description
3GPP TS 27.007
C
YES
References
O
SIM PIN
N
FI
D
Execution command causes the TA to return the information text <report>, which should offer the
user of the TA an extended report of the reason for:
1 The failure in the last unsuccessful call setup(originating or answering) or in-call
modification.
2 The last call release.
3 The last unsuccessful GPRS attach or unsuccessful PDP context activation.
4 The last GPRS detach or PDP context deactivation.
Syntax
O
M
Test Command
AT+CEER=?
Responses
+CEER:<report>
OK
M
C
Execution Command
AT+CEER
Responses
OK
SI
Defined values
<report>
Wrong information which is possibly occurred.
Examples
AT+CEER
+CEER: Invalid/incomplete number
SIM7500_SIM7600 Series_AT Command Manual_V1.07
117
2017-12-25
Smart Machine Smart Decision
OK
6.9
AT+CCWA Call waiting
Description
SIM PIN
References
3GPP TS 27.007
TI
YES
AL
FI
L
E
This command allows control of the Call Waiting supplementary service. Activation, deactivation
and status query are supported. When querying the status of a network service (<mode>=2) the
response line for 'not active' case (<status>=0) should be returned only if service is not active for
any <class>. Parameter <n> is used to disable/enable the presentation of an unsolicited result code
+CCWA: <number>,<type>,<class> to the TE when call waiting service is enabled. Command
should be abortable when network is interrogated.
EN
Syntax
OK
Responses
+CCWA: <n>
N
Read Command
AT+CCWA?
D
Responses
+CCWA: (list of supported <n>s)
FI
Test Command
AT+CCWA=?
Responses
When <mode>=2 and command successful:
C
Write Command
AT+CCWA=
<n>[,<mode>[,<class>]]
O
OK
+CCWA:<status>,<class>[<CR><LF>
O
M
+CCWA: <status>, <class>[...]]
ERROR
+CME ERROR: <err>
Responses
Set default value (<n>=0):
OK
SI
M
C
Execution Command
AT+CCWA
OK
Defined values
<n>
Sets/shows the result code presentation status in the TA
0 – disable
1 – enable
<mode>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
118
2017-12-25
FI
L
C
O
N
FI
D
EN
TI
AL
When <mode> parameter is not given, network is not interrogated:
0 – disable
1 – enable
2 – query status
<class>
It is a sum of integers each representing a class of information (default 7)
1
– voice (telephony)
2
– data (refers to all bearer services)
4
– fax (facsimile services)
7
– voice,data and fax(1+2+4)
8
– short message service
16
– data circuit sync
32
– data circuit async
64
– dedicated packet access
128 – dedicated PAD access
255 – The value 255 covers all classes
<status>
0 – not active
1 – active
<number>
String type phone number of calling address in format specified by <type>.
<type>
Type of address octet in integer format;
128 – Restricted number type includes unknown type and format
145 – International number type
129 – Otherwise
E
Smart Machine Smart Decision
Examples
M
C
O
M
AT+CCWA=?
+CCWA:(0-1)
OK
AT+CCWA?
+CCWA: 0
OK
AT+CHLD Call related supplementary services
SI
6.10
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
119
2017-12-25
Smart Machine Smart Decision
SIM PIN
References
3GPP TS 27.007
Syntax
Responses
+CHLD: (list of supported <n>s)
TI
Test Command
AT+CHLD=?
EN
OK
Responses
OK
ERROR
D
Write Command
AT+CHLD=<n>
AL
YES
FI
L
E
This command allows the control the following call related services:
1. A call can be temporarily disconnected from the ME but the connection is retained by the
network.
2. Multiparty conversation (conference calls).
3. The served subscriber who has two calls (one held and the other either active or alerting)
can connect the other parties and release the served subscriber's own connection.
Calls can be put on hold, recovered, released, added to conversation, and transferred. This is
based on the GSM/UMTS supplementary services.
FI
+CME ERROR: <err>
Responses
OK
N
Execution Command
AT+CHLD
Default to <n>=2.
O
ERROR
<n>
M
Defined values
C
+CME ERROR: <err>
SI
M
C
O
0
– Terminate all held calls; or set User Determined User Busy for a waiting call
1
– Terminate all active calls and accept the other call (waiting call or held call)
1X – Terminate a specific call X
2
– Place all active calls on hold and accept the other call (waiting call or held call) as
the active call
2X – Place all active calls except call X on hold
3
– Add the held call to the active calls
4
– Connect two calls and cut off the connection between users and them simultaneously
Examples
AT+CHLD=?
+CHLD: (0,1,1x,2,2x,3,4)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
120
2017-12-25
Smart Machine Smart Decision
6.11
AT+CCFC Call forwarding number and conditions
Description
YES
References
FI
L
SIM PIN
E
This command allows control of the call forwarding supplementary service. Registration, erasure,
activation, deactivation, and status query are supported.
3GPP TS 27.007
Test Command
AT+CCFC=?
Responses
+CCFC: (list of supported <reason>s)
EN
Responses
When <mode>=2 and command successful:
+CCFC: <status>,<class1>[,<number>,<type>
[,<subaddr>,<satype>[,<time>]]][<CR><LF>
D
Write Command
AT+CCFC=<reason>,<mode
>[,<number>[,<type>[,<clas
s>[,<subaddr>[,<satype>[,<ti
me> ]]]]]]
TI
OK
AL
Syntax
+CCFC: <status>,<class2>[,<number>,<type>
N
OK
FI
[,<subaddr>,<satype>[,<time>]]][...]]
ERROR
Defined values
C
O
+CME ERROR:<err>
SI
M
C
O
M
<reason>
0 – unconditional
1 – mobile busy
2 – no reply
3 – not reachable
4 – all call forwarding
5 – all conditional call forwarding
<mode>
0 – disable
1 – enable
2 – query status
3 – registration
4 – erasure
<number>
String type phone number of forwarding address in format specified by <type>.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
121
2017-12-25
Smart Machine Smart Decision
Examples
C
O
M
AT+CCFC=?
+CCFC: (0,1,2,3,4,5)
OK
AT+CCFC=0,2
+CCFC: 0,255
OK
C
O
N
FI
D
EN
TI
AL
FI
L
E
<type>
Type of address octet in integer format:
145 – dialing string <number> includes international access code character ‘+’
129 – otherwise
<subaddr>
String type sub address of format specified by <satype>.
<satype>
Type of sub address octet in integer format, default 128.
<classX>
It is a sum of integers each representing a class of information (default 7):
1
– voice (telephony)
2
– data (refers to all bearer services)
4
– fax (facsimile services)
16
– data circuit sync
32 – data circuit async
64
– dedicated packet access
128 – dedicated PAD access
255 – The value 255 covers all classes
<time>
1...30 – when "no reply" is enabled or queried, this gives the time in seconds to wait before call
is forwarded, default value 20.
<status>
0 – not active
1 – active
AT+CLIP Calling line identification presentation
SI
M
6.12
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
122
2017-12-25
Smart Machine Smart Decision
SIM PIN
References
3GPP TS 27.007
AL
YES
FI
L
E
This command refers to the GSM/UMTS supplementary service CLIP (Calling Line Identification
Presentation) that enables a called subscriber to get the calling line identity (CLI) of the calling
party when receiving a mobile terminated call.
Write command enables or disables the presentation of the CLI at the TE. It has no effect on the
execution of the supplementary service CLIP in the network.
When the presentation of the CLI at the TE is enabled (and calling subscriber allows), +CLIP:
<number>,<type>,,[,[<alpha>][,<CLI validity>]] response is returned after every RING (or
+CRING: <type>; refer sub clause "Cellular result codes +CRC") result code sent from TA to TE. It
is manufacturer specific if this response is used when normal voice call is answered.
Responses
+CLIP: (list of supported <n>s)
OK
OK
D
Responses
+CLIP: <n>,<m>
FI
Read Command
AT+CLIP?
EN
Test Command
AT+CLIP=?
TI
Syntax
N
ERROR
+CME ERROR: <err>
O
Responses
OK
C
Write Command
AT+CLIP=<n>
ERROR
+CME ERROR: <err>
Responses
Set default value(<n>=0):
OK
C
O
M
Execution Command
AT+CLIP
M
Defined values
SI
<n>
Parameter sets/shows the result code presentation status in the TA:
0 – disable
1 – enable
<m>
0 – CLIP not provisioned
1 – CLIP provisioned
2 – unknown (e.g. no network, etc.)
<number>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
123
2017-12-25
Smart Machine Smart Decision
EN
TI
AL
FI
L
E
String type phone number of calling address in format specified by <type>.
<type>
Type of address octet in integer format;
128 – Restricted number type includes unknown type and format
145 – International number type
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
129 – Otherwise
<alpha>
String type alphanumeric representation of <number> corresponding to the entry found in phone
book.
<CLI validity>
0 – CLI valid
1 – CLI has been withheld by the originator
2 – CLI is not available due to interworking problems or limitations of originating
network
O
AT+CLIR Calling line identification restriction
C
6.13
N
FI
AT+CLIP=1
OK
RING (with incoming call)
+CLIP: "02152063113",128,,,"gongsi",0
D
Examples
Description
SI
M
C
O
M
This command refers to CLIR-service that allows a calling subscriber to enable or disable the
presentation of the CLI to the called party when originating a call.
Write command overrides the CLIR subscription (default is restricted or allowed) when temporary
mode is provisioned as a default adjustment for all following outgoing calls. This adjustment can be
revoked by using the opposite command.. If this command is used by a subscriber without
provision of CLIR in permanent mode the network will act.
Read command gives the default adjustment for all outgoing calls (given in <n>), and also triggers
an interrogation of the provision status of the CLIR service (given in <m>).
Test command returns values supported as a compound value.
SIM PIN
YES
References
3GPP TS 27.007
Syntax
Test Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
124
2017-12-25
Smart Machine Smart Decision
AT+CLIR=?
+CLIR: (list of supported <n>s)
OK
Read Command
AT+CLIR?
Responses
+CLIR: <n>,<m>
OK
E
ERROR
Write Command
AT+CLIR=<n>
FI
L
+CME ERROR: <err>
Responses
OK
AL
ERROR
TI
+CME ERROR: <err>
Defined values
EN
<n>
– presentation indicator is used according to the subscription of the CLIR service
– CLIR invocation
– CLIR suppression
0
1
2
3
4
–
–
–
–
–
D
0
1
2
FI
<m>
C
O
N
CLIR not provisioned
CLIR provisioned in permanent mode
unknown (e.g. no network, etc.)
CLIR temporary mode presentation restricted
CLIR temporary mode presentation allowed
Examples
AT+COLP Connected line identification presentation
M
C
6.14
O
M
AT+CLIR=?
+CLIR:(0-2)
OK
Description
SI
This command refers to the GSM/UMTS supplementary service COLP(Connected Line
Identification Presentation) that enables a calling subscriber to get the connected line identity
(COL) of the called party after setting up a mobile originated call. The command enables or
disables the presentation of the COL at the TE. It has no effect on the execution of the
supplementary service COLR in the network.
When enabled (and called subscriber allows), +COLP:<number>, <type> [,<subaddr>, <satype>
[,<alpha>]] intermediate result code is returned from TA to TE before any +CR responses. It is
SIM7500_SIM7600 Series_AT Command Manual_V1.07
125
2017-12-25
Smart Machine Smart Decision
manufacturer specific if this response is used when normal voice call is established.
When the AT+COLP=1 is set, any data input immediately after the launching of “ATDXXX;” will
stop the execution of the ATD command, which may cancel the establishing of the call.
SIM PIN
3GPP TS 27.007
E
YES
References
Test Command
AT+COLP=?
FI
L
Syntax
Responses
+COLP: (list of supported <n>s)
Read Command
AT+COLP?
AL
OK
Responses
+COLP: <n>,<m>
TI
OK
EN
ERROR
Write Command
AT+COLP =<n>
Responses
OK
FI
ERROR
D
+CME ERROR: <err>
+CME ERROR: <err>
O
C
Defined values
Responses
Set default value(<n>=0, <m>=0):
OK
N
Execution Command
AT+COLP
SI
M
C
O
M
<n>
Parameter sets/shows the result code presentation status in the TA:
0 – disable
1 – enable
<m>
0 – COLP not provisioned
1 – COLP provisioned
2 – unknown (e.g. no network, etc.)
Examples
AT+COLP?
+COLP: 1,0
OK
ATD10086;
VOICE CALL: BEGIN
SIM7500_SIM7600 Series_AT Command Manual_V1.07
126
2017-12-25
Smart Machine Smart Decision
+COLP: "10086",129,,,
OK
DTMF and tone generation
E
AT+VTS
FI
L
6.15
Description
3GPP TS 27.007
Syntax
D
NO
References
EN
SIM PIN
TI
AL
This command allows the transmission of DTMF tones and arbitrary tones which cause the Mobile
Switching Center (MSC) to transmit tones to a remote subscriber. The command can only be used
in voice mode of operation (active voice call).
NOTE: The END event of voice call will terminate the transmission of tones, and as an operator
option, the tone may be ceased after a pre-determined time whether or not tone duration has been
reached.
Responses
AT+VTS=?
+VTS: (list of supported<dtmf>s)
OK
Write Command
AT+VTS=<dtmf>
[,<duration>]
Responses
OK
C
O
N
FI
Test Command
ERROR
M
AT+VTS=<dtmf-string>
O
Defined values
SI
M
C
<dtmf>
A single ASCII character in the set 0-9, *, #, A, B, C, D.
<duration>
Tone duration in 1/10 seconds, from 0 to 255. This is interpreted as a DTMF tone of different
duration from that mandated by the AT+VTD command, otherwise, the duration which be set the
AT+VTD command will be used for the tone (<duration> is omitted).
<dtmf-string>
A sequence of ASCII character in the set 0-9, *, #, A, B, C, D, and maximal length of the string is
29. The string must be enclosed in double quotes (“”), and separated by commas between the ASCII
characters (e.g. “1,3,5,7,9,*”). Each of the tones with a duration which is set by the AT+VTD
command.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
127
2017-12-25
Smart Machine Smart Decision
Examples
FI
L
AL
AT+VTD Tone duration
TI
6.16
E
AT+VTS=1
OK
AT+VTS=1,20
OK
AT+VTS=”1,3,5”
OK
AT+VTS=?
+VTS: (0-9,*,#,A,B,C,D)
OK
Description
3GPP TS 27.007
FI
YES
References
D
SIM PIN
EN
This refers to an integer <n> that defines the length of tones emitted as a result of the AT+VTS
command. A value different than zero causes a tone of duration <n>/10 seconds.
N
Syntax
C
M
Read Command
AT+VTD?
Write Command
Responses
+VTD: <n>
OK
Responses
OK
C
O
AT+VTD=<n>
Responses
+VTD: (list of supported <n>s)
OK
O
Test Command
AT+VTD=?
M
Defined values
SI
<n>
Tone duration in integer format, from 0 to 255, and 0 is factory value.
0
Tone duration of every single tone is dependent on the network.
1…255 Tone duration of every single tone in 1/10 seconds.
Examples
AT+VTD=?
+VTD: (0-255)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
128
2017-12-25
Smart Machine Smart Decision
AT+CSTA Select type of address
FI
L
6.17
E
OK
AT+VTD?
+VTD: 0
OK
AT+VTD=5
OK
Description
YES
References
EN
SIM PIN
TI
AL
Write command is used to select the type of number for further dialing commands (ATD) according
to GSM/UMTS specifications.
Read command returns the current type of number.
Test command returns values supported by the Module as a compound value.
3GPP TS 27.007
FI
D
Syntax
M
C
O
Read Command
AT+CSTA?
Write Command
AT+CSTA=<type>
ERROR
Responses
OK
C
O
Execution Command
AT+CSTA
Responses
+CSTA:(list of supported <type>s)
OK
Responses
+CSTA:<type>
OK
Responses
OK
N
Test Command
AT+CSTA=?
M
Defined values
SI
<type>
Type of address octet in integer format:
145 – when dialling string includes international access code character “+”
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
129 – otherwise
NOTE: Because the type of address is automatically detected on the dial string of dialing
command, command AT+CSTA has really no effect.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
129
2017-12-25
Smart Machine Smart Decision
Examples
FI
L
6.18
E
AT+CSTA?
+CSTA: 129
OK
AT+CSTA=145
OK
AT+CMOD Call mode
AL
Description
NO
References
EN
SIM PIN
TI
Write command selects the call mode of further dialing commands (ATD) or for next answering
command (ATA). Mode can be either single or alternating.
Test command returns values supported by the TA as a compound value.
3GPP TS 27.007
D
Syntax
Responses
+CMOD: (list of supported <mode>s)
OK
Read Command
AT+CMOD?
Responses
+CMOD: <mode>
OK
N
O
C
M
Write Command
AT+CMOD=<mode>
FI
Test Command
AT+CMOD=?
ERROR
Responses
Set default value:
OK
M
C
O
Execution Command
AT+CMOD
Responses
OK
Defined values
SI
<mode>
0 – single mode(only supported)
NOTE: The value of <mode> shall be set to zero after a successfully completed alternating mode
call. It shall be set to zero also after a failed answering. The power-on, factory and user resets shall
also set the value to zero. This reduces the possibility that alternating mode calls are originated or
answered accidentally.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
130
2017-12-25
Smart Machine Smart Decision
Examples
AT+VMUTE
FI
L
6.19
E
AT+CMOD?
+CMOD: 0
OK
AT+CMOD=0
OK
Speaker mute control
AL
Description
SIM PIN
References
Vendor
EN
NO
TI
This command is used to control the loudspeaker to mute and unmute during a voice call or a video
call which is connected. If there is not a connected call, write command can’t be used.
When all calls are disconnected, the Module sets the subparameter as 0 automatically.
D
Syntax
Responses
+VMUTE: (list of supported <mode>s)
OK
Read Command
AT+VMUTE?
Responses
+VMUTE: <mode>
OK
C
O
N
FI
Test Command
AT+VMUTE=?
M
Write Command
AT+VMUTE=<mode>
Responses
OK
ERROR
O
Defined values
mute off
mute on
SI
M
C
<mode>
0 –
1 –
Examples
AT+VMUTE=1
OK
AT+VMUTE?
+VMUTE:1
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
131
2017-12-25
Smart Machine Smart Decision
6.20
AT+CMUT Microphone mute control
Description
3GPP TS 27.007
Syntax
Responses
+CMUT: (list of supported <mode>s)
OK
Responses
+CMUT: <mode>
OK
Responses
OK
FI
Write Command
AT+CMUT=<mode>
D
Read Command
AT+CMUT?
EN
TI
Test Command
AT+CMUT=?
AL
NO
References
FI
L
SIM PIN
E
This command is used to enable and disable the uplink voice muting during a voice call or a video
call which is connected. If there is not a connected call, write command can’t be used.
When all calls are disconnected, the Module sets the subparameter as 0 automatically.
N
ERROR
Examples
C
mute off
mute on
M
<mode>
0 –
1 –
O
Defined values
SI
M
C
O
AT+CMUT=1
OK
AT+CMUT?
+CMUT: 1
OK
6.21
AT+MORING Enable or disable report MO ring URC
Description
This command is used to enable or disable report MO ring URC
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
132
2017-12-25
Smart Machine Smart Decision
NO
Vendor
Syntax
Write Command
AT+MORING=<mode>
E
FI
L
Read Command
AT+MORING?
Responses
+MORING: (0-1)
OK
Responses
+ MORING: <mode>
OK
Responses
OK
AL
Test Command
AT+MORING=?
TI
ERROR
EN
Defined values
FI
D
<mode>
Enable or disable report MO ring URC:
0 – disable
1 – enable.
C
O
C
O
M
AT+MORING=1
OK
AT+MORING?
+MORING:1
OK
AT+MORING=?
+MORING: (0-1)
OK
N
Examples
AT+CSDVC
M
6.22
Switch voice channel device
SI
Description
This command is used to switch voice channel device. After changing current voice channel device
and if there is a connecting voice call, it will use the settings of previous device (loudspeaker
volume level, mute state of loudspeaker and microphone, refer to AT+CLVL, AT+VMUTE, and
AT+CMUT).
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
133
2017-12-25
Smart Machine Smart Decision
NO
Vendor
Responses
+CSDVC: (list of supported <dev>s)
OK
Read Command
AT+CSDVC?
Responses
+CSDVC: <dev>
OK
Write Command
AT+CSDVC=<dev>
Responses
OK
TI
AL
FI
L
Test Command
AT+CSDVC=?
Defined values
D
EN
<dev>
1 – handset
3 – speaker phone
N
O
C
AT+CSDVC=1
OK
AT+CSDVC?
+CSDVC:1
OK
FI
Examples
AT+CLVL Loudspeaker volume level
M
6.23
E
Syntax
O
Description
M
C
Write command is used to select the volume of the internal loudspeaker audio output of the device.
Test command returns supported values as compound value.
SI
SIM PIN
NO
References
3GPP TS 27.007
Syntax
Test Command
AT+CLVL=?
Responses
+CLVL: (list of supported <level>s)
OK
Read Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
134
2017-12-25
Smart Machine Smart Decision
AT+CLVL?
+CLVL: <level>
OK
Write Command
AT+CLVL=<level>
Responses
OK
E
ERROR
FI
L
Defined values
AL
<level>
Integer type value which represents loudspeaker volume level. The range is from 0 to 5, and 0
represents the lowest loudspeaker volume level, 4 is default factory value.
NOTE: <level> is nonvolatile, and it is stored when restart.
TI
Examples
D
FI
N
AT+SIDET Set sidetone
O
6.24
EN
AT+CLVL?
+CLVL:4
OK
AT+CLVL=3
OK
C
Description
This command is used to enable or disable sidetone. Please refer to related hardware design
document for more information. This command is only used after call start.
Vendor
O
NO
References
M
SIM PIN
C
Syntax
SI
M
Test Command
AT+SIDET=?
Responses
+SIDET: (list of supported <en>s)
OK
Read Command
AT+SIDET?
Responses
+SIDET: <en>
OK
Write Command
AT+SIDET=<en>
Responses
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
135
2017-12-25
Smart Machine Smart Decision
Defined values
<en>
0: disable sidetone
1: enable sidetone
E
Examples
AL
TI
EN
AT+CACDBFN
Change default ACDB filename
D
6.25
FI
L
AT+SIDET?
+SIDET: 0
OK
AT+SIDET=?
+SIDET: (0-1)
OK
AT+SIDET=1
OK
FI
Description
NO
References
Vendor
C
SIM PIN
O
N
This command is used to change default acdb filename. But there are six adcd files used by system,
we can’t change default acdb filename to them. These filenames including Bluetooth_cal.acdb,
General_cal.acdb, Global_cal.acdb, Hdmi_cal.acdb, Headset_cal.acdb, Speaker_cal.acdb
M
Syntax
C
O
Test Command
AT+CACDBFN=?
SI
M
Read Command
AT+CACDBFN?
Write Command
AT+CACDBFN=<acdb file>
Responses
+CACDBFN: (acdb file(s) listed in /data <acdb file>s,except s
ix acdb file used by system)
OK
Responses
+CACDBFN: <acdb file>
OK
Responses
OK
ERROR
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
136
2017-12-25
Smart Machine Smart Decision
<acdb file>
<acdb file> file(s) in the directory /data with suffix: acdb, except six acdb file used by system
Examples
FI
L
AL
TI
AT+CPCMREG USB audio control
EN
6.26
E
AT+CACDBFN=Handset_cal.acdb
OK
AT+CACDBFN?
+CACDBFN: Handset_cal.acdb
OK
AT+CACDBFN=?
+CACDBFN: (Handset_cal.acdb,Handset_tianmai.acdb)
OK
Description
Vendor
N
NO
References
FI
SIM PIN
D
This command is used to start/stop usb audio function.
O
M
Read Command
AT+CPCMREG?
Write Command
AT+CPCMREG=<mode>
C
Responses
+CPCMREG: (list of supported < mode >s)
OK
C
Test Command
AT+CPCMREG=?
O
Syntax
Responses
+CPCMREG: <mode>
OK
Responses
OK
SI
M
ERROR
Defined values
<mode>
0 –
1 –
stop usb audio function,need used after call stop.
start usb audio function,need used after call start(ATDxxx;)
Examples
SIM7500_SIM7600 Series_AT Command Manual_V1.07
137
2017-12-25
Smart Machine Smart Decision
AT+CMICGAIN Adjust mic gain
FI
L
6.27
E
AT+CPCMREG=1
OK
AT+CPCMREG?
+CPCMREG:1
OK
Description
Vendor
EN
NO
References
TI
SIM PIN
AL
This command is used to adjust mic gain. If this command was used during call, it will take
immediate effect. Otherwise, it will take effect in next call.
Syntax
Responses
+CMICGAIN: (list of supported <value>s)
OK
Read Command
AT+CMICGAIN?
Responses
+CMICGAIN: <value>
OK
Responses
OK
C
Write Command
AT+CMICGAIN=<value>
O
N
FI
D
Test Command
AT+CMICGAIN=?
M
ERROR
Defined values
M
C
O
<value>
Gain value from 0-8, 8 is the max. 3 is the default value. This value will be reset to default value
after Module reset.
SI
Examples
AT+CMICGAIN=1
OK
AT+CMICGAIN?
+CMICGAIN:1
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
138
2017-12-25
Smart Machine Smart Decision
6.28
AT+COUTGAIN Adjust out gain
Description
SIM PIN
References
Vendor
FI
L
NO
E
This command is used to adjust out(speaker/handset) gain. If this command was used during call, it
will take immediate effect . Otherwise, it will take effect in next call.
AL
Syntax
Responses
+COUTGAIN: (list of supported <value>s)
OK
Read Command
AT+COUTGAIN?
Responses
+COUTGAIN: <value>
OK
Write Command
AT+COUTGAIN=<value>
Responses
OK
EN
D
N
FI
ERROR
TI
Test Command
AT+COUTGAIN=?
O
Defined values
C
<mode>
Gain value from 0-8, 8 is the max. 8 is the default value. This value will be reset to default value
after Module reset.
M
Examples
SI
M
C
O
AT+COUTGAIN=1
OK
AT+COUTGAIN?
+ COUTGAIN:1
OK
6.29
AT+CTXVOL Adjust TX voice mic volume
Description
This command is used to adjust mic gain. It modify the TX_VOICE_VOL in DSP. This command
only be used during call and don’t save the parameter after call.
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
139
2017-12-25
Smart Machine Smart Decision
NO
Vendor
Responses
+CTXVOL: (list of supported <value>s)
OK
Read Command
AT+CTXVOL?
Responses
+CTXVOL: <value>
OK
Write Command
AT+CTXVOL=<value>
Responses
OK
AL
FI
L
Test Command
AT+CTXVOL=?
E
Syntax
TI
ERROR
EN
Defined values
D
<value>
Gain value from 0x0000-0xffff, default value is not a fixed value. It varies with different versions.
N
O
C
AT+CTXVOL=0x1234
OK
AT+CTXVOL?
+CTXVOL: 0x2d33
OK
FI
Examples
M
AT+CTXMICGAIN Adjust TX voice mic gain
O
6.30
Description
M
C
This command is used to adjust mic gain. It modify the TX_VOICE_MIC_GAIN in DSP. This
command only be used during call and don’t save the parameter after call.
SI
SIM PIN
NO
References
Vendor
Syntax
Test Command
Responses
AT+CTXMICGAIN=?
+CTXMICGAIN: (list of supported <mode>,<value>s)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
140
2017-12-25
Smart Machine Smart Decision
Read Command
Responses
AT+CTXMICGAIN?
+CTXMICGAIN: <mode>,<value>
OK
Write Command
Responses
AT+CTXMICGAIN=<mode
>,<value>
OK
FI
L
E
ERROR
Defined values
TI
AL
<mode>
mode value from 0-1, default value is not a fixed value. It varies with different versions.
<value>
gain value from 0x0000-0xffff, default value is not a fixed value. It varies with different versions.
EN
Examples
FI
N
O
AT+CRXVOL Adjust RX voice output speaker volume
C
6.31
D
AT+CTXMICGAIN=1,0x1234
OK
AT+CTXMICGAIN?
+ CTXMICGAIN: 1,0x2000
OK
Description
M
This command is used to adjust digital Volume of output signal after speech decoder, before
summation of sidetone and DAC. It modify the RX_VOICE_SPK_GAIN in DSP. This command
only be used during call and don’t save the parameter after call.
References
O
SIM PIN
Vendor
C
NO
M
Syntax
Responses
+CRXVOL: (list of supported <value>s)
OK
Read Command
AT+CRXVOL?
Responses
+CRXVOL: <value>
OK
Write Command
Responses
SI
Test Command
AT+CRXVOL=?
SIM7500_SIM7600 Series_AT Command Manual_V1.07
141
2017-12-25
Smart Machine Smart Decision
AT+CRXVOL=<value>
OK
ERROR
Defined values
FI
L
E
<value>
Gain value from 0x0000-0xffff, default value is not a fixed value. It varies with different versions.
AL
Examples
EN
D
AT+CECH
Inhibit far-end echo
FI
6.32
TI
AT+CRXVOL=0x1234
OK
AT+CRXVOL?
+CRXVOL: 0x3fd9
OK
N
Description
SIM PIN
Vendor
O
Syntax
References
M
NO
C
O
This command is used to adjust additional muting gain applied in DES during far-end only. It
modify the DENS_gamma_e_high of TX_VOICE_SMECNS in DSP. The bigger the value, the
stronger the inhibition .This command only be used during call and don’t save the parameter after
call.
M
C
Test Command
AT+CECH=?
Responses
+CECH: (list of supported <value>s)
OK
Responses
+CECH: <value>
OK
Write Command
AT+CECH=<value>
Responses
OK
SI
Read Command
AT+CECH?
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
142
2017-12-25
Smart Machine Smart Decision
Defined values
<value>
Gain value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
E
Examples
AL
AT+CECDT Inhibit echo during doubletalk
TI
6.33
FI
L
AT+CECH=0x1234
OK
AT+CECH?
+CECH: 0x0200
OK
EN
Description
Vendor
N
NO
References
FI
SIM PIN
D
This command is used to adjust additional muting gain applied in DES during doubletalk. It modify
the DENS_gamma_e_dt of TX_VOICE_SMECNS in DSP. The bigger the value, the stronger the
inhibition .This command only be used during call and don’t save the parameter after call.
O
M
Read Command
AT+CECDT?
Responses
+CECDT: <value>
OK
Responses
OK
ERROR
SI
M
C
Write Command
AT+CECDT=<value>
Responses
+CECDT: (list of supported <value>s)
OK
C
Test Command
AT+CECDT=?
O
Syntax
Defined values
<value>
Gain value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
Examples
AT+CECDT=0x1234
SIM7500_SIM7600 Series_AT Command Manual_V1.07
143
2017-12-25
Smart Machine Smart Decision
AT+CECWB Inhibit echo in the high band
FI
L
6.34
E
OK
AT+CECDT?
+CECDT: 0x0100
OK
Description
NO
References
EN
SIM PIN
TI
AL
This command is used to adjust the aggressiveness of EC in the high band (4 ~ 8 kHz). A higher
value is more aggressive and suppresses more high-band echo. Q-format - Q4.11WB_gamma_E =
2048 * gammaWhere gamma is in the range [0,15]. It modify the WB_gamma_e of
TX_VOICE_SMECNS in DSP. The bigger the value, the stronger the inhibition .This command
only be used during call and don’t save the parameter after call.
Vendor
D
Syntax
Responses
+CECWB: (list of supported <value>s)
OK
Read Command
AT+CECWB?
Responses
+CECWB: <value>
OK
C
O
N
FI
Test Command
AT+CECWB=?
Responses
OK
ERROR
O
M
Write Command
AT+CECWB=<value>
C
Defined values
M
<value>
Gain value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
SI
Examples
AT+CECWB=0x1234
OK
AT+CECWB?
+CECWB: 0x0300
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
144
2017-12-25
Smart Machine Smart Decision
6.35
AT+CNSN MIC NOISE suppression
Description
SIM PIN
References
Vendor
Syntax
Responses
+CNSN: (list of supported <value>s)
OK
Read Command
AT+CNSN?
Responses
+CNSN: <value>
OK
Write Command
AT+CNSN=<value>
Responses
OK
FI
D
EN
TI
Test Command
AT+CNSN=?
AL
NO
FI
L
E
This command is used to adjust oversubtraction factor and bias compensation for noise estimation.
It modify the DENS_gamma_n of TX_VOICE_SMECNS in DSP. The bigger the value, the
stronger the noise suppression .This command only be used during call and don’t save the
parameter after call.
O
N
ERROR
C
Defined values
Examples
M
<value>
Gain value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
SI
M
C
O
AT+CNSN=0x1234
OK
AT+CNSN?
+CNSN: 0x0258
OK
6.36
AT+CNSLIM MIC NOISE suppression
Description
This command is used to controls the maximum amount of noise suppression. It modify the
DENS_limit_NS of TX_VOICE_SMECNS in DSP. The bigger the value, the stronger the noise
SIM7500_SIM7600 Series_AT Command Manual_V1.07
145
2017-12-25
Smart Machine Smart Decision
suppression .This command only be used during call and don’t save the parameter after call.
SIM PIN
NO
References
Vendor
Read Command
AT+CNSLIM?
Responses
+CNSLIM: <value>
OK
Write Command
Responses
AT+CNSLIM=<value>
OK
FI
L
Responses
+CNSLIM: (list of supported <value>s)
OK
TI
AL
Test Command
AT+CNSLIM=?
E
Syntax
EN
ERROR
D
Defined values
FI
<value>
Gain value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
O
C
AT+CFNSMOD
O
6.37
M
AT+CNSLIM=0x1234
OK
AT+CNSLIM?
+CNSLIM: 0x16c4
OK
N
Examples
Adjust parameter fnsMode of RX_VOICE_FNS
C
Description
M
This command is used to modify the fnsMode of RX_VOICE_FNS in DSP. This command only be
used during call and don’t save the parameter after call.
SI
SIM PIN
NO
References
Vendor
Syntax
Test Command
Responses
AT+CFNSMOD=?
+CFNSMOD: (list of supported <value>s)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
146
2017-12-25
Smart Machine Smart Decision
OK
Responses
AT+CFNSMOD?
+CFNSMOD: <value>
OK
Write Command
Responses
AT+CFNSMOD=<value>
OK
E
Read Command
FI
L
ERROR
Defined values
EN
TI
AL
<value>
Gain value is bellow, default value is not a fixed value. It varies with different versions.
0x00FF – Maximum NS
0x0073 – Basic stationary NS
0x00F3 – Enhanced stationary NS
0x01FF – Aggressive NS
FI
N
AT+CFNSIN Adjust parameter fnsInputGain of RX_VOICE_FNS
C
6.38
O
AT+CFNSMOD=0x0073
OK
AT+CFNSMOD?
+CFNSMOD: 0x0073
OK
D
Examples
M
Description
O
This command is used to modify the fnsInputGain of RX_VOICE_FNS in DSP. This command
only be used during call and don’t save the parameter after call.
SIM PIN
Vendor
M
C
NO
References
SI
Syntax
Test Command
AT+CFNSIN=?
Responses
+CFNSIN: (list of supported <value>s)
OK
Read Command
Responses
AT+CFNSIN?
+CFNSIN: <value>
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
147
2017-12-25
Smart Machine Smart Decision
Write Command
Responses
AT+CFNSIN=<value>
OK
ERROR
E
Defined values
FI
L
<value>
Gain value from 0x2000-0x7fff, default value is not a fixed value. It varies with different versions.
Examples
TI
EN
AT+CFNSLVL Adjust parameter fnsTargetNS of RX_VOICE_FNS
D
6.39
AL
AT+CFNSIN=0x2234
OK
AT+CFNSIN?
+CFNSIN: 0x2000
OK
FI
Description
SIM PIN
O
Vendor
C
NO
References
N
This command is used to modify the fnsTargetNS of RX_VOICE_FNS in DSP. This command only
be used during call and don’t save the parameter after call.
Syntax
O
M
Test Command
AT+CFNSLVL=?
M
C
Read Command
AT+CFNSLVL?
SI
Write Command
AT+CFNSLVL=<value>
Responses
+CFNSLVL: (list of supported <value>s)
OK
Responses
+CFNSLVL: <value>
OK
Responses
OK
ERROR
Defined values
<value>
Gain value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
148
2017-12-25
Smart Machine Smart Decision
Examples
FI
L
6.40
E
AT+CFNSLVL=0x2234
OK
AT+CFNSLVL?
+CFNSLVL: 0x1000
OK
AT+CECRX Enable or disable VOICE_MOD_ENABLE
AL
Description
SIM PIN
References
Vendor
EN
NO
TI
This command is used to enable or disable VOICE_MOD_ENABLE. It modify the
VOICE_MOD_ENABLE in DSP. This command only be used during call and don’t save the
parameter after call.
D
Syntax
Responses
+CECRX: (list of supported <value>s)
OK
Read Command
AT+CECRX?
Responses
+CECRX: <value>
OK
N
O
C
M
Write Command
AT+CECRX=<value>
FI
Test Command
AT+CECRX=?
Responses
OK
ERROR
O
Defined values
SI
M
C
<value>
This default value is not a fixed value. It varies with different versions.
1: Enable
0: Disable
Examples
AT+CECRX=1
OK
AT+CECRX?
+CECRX: 1
SIM7500_SIM7600 Series_AT Command Manual_V1.07
149
2017-12-25
Smart Machine Smart Decision
OK
6.41
AT+CNLPPG Modify the NLPP_gain in DSP
E
Description
SIM PIN
References
Vendor
AL
NO
FI
L
This command is used to modify the NLPP_gain of VOICE_ECRX_PARAM in DSP. This
command only be used during call and don’t save the parameter after call.
TI
Syntax
Responses
+CNLPPG: (list of supported <value>s)
OK
Read Command
AT+CNLPPG?
Responses
+CNLPPG: <value>
OK
Write Command
AT+CNLPPG =<value>
Responses
OK
N
FI
D
EN
Test Command
AT+CNLPPG=?
C
Defined values
O
ERROR
O
Examples
M
<value>
Gain value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
SI
M
C
AT+CNLPPG=0x1234
OK
AT+CNLPPG?
+CNLPPG: 0x1000
OK
6.42
AT+CNLPPL Modify the NLPP_limit in DSP
Description
This command is used to modify the NLPP_limit of VOICE_ECRX_PARAM in DSP. This
SIM7500_SIM7600 Series_AT Command Manual_V1.07
150
2017-12-25
Smart Machine Smart Decision
command only be used during call and don’t save the parameter after call.
SIM PIN
NO
References
Vendor
Responses
AT+CNLPPL=?
+CNLPPL: (list of supported <value>s)
OK
Read Command
AT+CNLPPL?
Responses
+CNLPPL: <value>
OK
Write Command
AT+CNLPPL =<value>
Responses
OK
TI
AL
Test Command
FI
L
E
Syntax
EN
ERROR
D
Defined values
AT+CECM Adjust echo canceller
O
6.43
M
C
AT+CNLPPL=0x1234
OK
AT+CNLPPL?
+CNLPPL: 0x7fff
OK
O
Examples
N
FI
<value>
Value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
C
Description
M
This AT command is used to select the echo cancellation mode. Write command only be used
during call.
SI
SIM PIN
NO
References
Vendor
Syntax
Test Command
Responses
AT+CECM=?
+CECM: (list of supported <value>s)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
151
2017-12-25
Smart Machine Smart Decision
OK
Responses
AT+CECM?
+CECM: <value>
OK
Write Command
Responses
AT+CECM=<value>
OK
E
Read Command
FI
L
ERROR
N
FI
D
EN
TI
<value>
This default value is not a fixed value. It varies with different versions.
0: disable EC mode
1: EC mode recommended for Handset
2: EC mode recommended for Headset
3: EC mode recommended for HANDSFREE
4: EC mode recommended for Bluetooth (least aggressive)
5: EC mode recommended for Bluetooth (less aggressive)
6: EC mode recommended for Bluetooth
7: EC mode recommended for Speaker least aggressive
8: EC mode recommended for Speaker phone medium
9: EC mode recommended for Speaker phone aggressive
AL
Defined values
C
AT+CPCMFRM
C
6.44
O
M
AT+CECM=1
OK
AT+CECM?
+CECM: 1
OK
O
Examples
Set usb audio sample rate to 16k bit
M
Description
SI
This command is used to set usb audio sample rate to 16K bit.
NOTE: This command only support for usb audio 8k to 16k switching, but not support for 16k to
8k switching.
IM PIN
NO
References
Vendor
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
152
2017-12-25
Smart Machine Smart Decision
Responses
+CPCMFRM: (list of supported <value>s)
OK
Read Command
AT+CPCMFRM?
Responses
+CPCMFRM: <value>
OK
Write Command
AT+CPCMFRM=<value>
Responses
OK
FI
L
E
Test Command
AT+CPCMFRM=?
AL
ERROR
Defined values
EN
TI
<value>
Gain value from 0-1, default value is 0.
0 : usb audio use 8k bit
1 : usb audio use 16k bit
D
Examples
SI
M
C
O
M
C
O
N
FI
AT+CPCMFRM=1
OK
AT+CPCMFRM?
+CPCMFRM: 1
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
153
2017-12-25
Smart Machine Smart Decision
AT+CSMS Select message service
FI
L
7.1
AT Commands for SMS
E
7
Description
SIM PIN
References
3GPP TS 27.005
TI
YES
AL
This command is used to select messaging service <service>.
Note: This command not support in CDMA/EVDO mode
EN
Syntax
Responses
+CSMS: (list of supported <service>s)
OK
Read Command
AT+CSMS?
Responses
+CSMS: <service>,<mt>,<mo>,<bm>
OK
Write Command
AT+CSMS=<service>
Responses
+CSMS: <mt>,<mo>,<bm>
OK
C
O
N
FI
D
Test Command
AT+CSMS=?
ERROR
M
+CMS ERROR: <err>
O
Defined values
SI
M
C
<service>
0 – SMS at command is compatible with GSM phase 2.
1 – SMS at command is compatible with GSM phase 2+.
<mt>
Mobile terminated messages:
0 – type not supported.
1 – type supported.
<mo>
Mobile originated messages:
0 – type not supported.
1 – type supported.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
154
2017-12-25
Smart Machine Smart Decision
<bm>
Broadcast type messages:
0 – type not supported.
1 – type supported.
E
Examples
AL
TI
EN
AT+CPMS Preferred message storage
D
7.2
FI
L
AT+CSMS=0
+CSMS:1,1,1
OK
AT+CSMS?
+CSMS:0,1,1,1
OK
AT+CSMS=?
+CSMS:(0-1)
OK
FI
Description
References
O
SIM PIN
N
This command is used to select memory storages <mem1>, <mem2> and <mem3> to be used for
reading, writing, etc.
3GPP TS 27.005
C
YES
Syntax
O
M
Test Command
AT+CPMS=?
SI
M
C
Read Command
AT+CPMS?
Write Command
AT+CPMS=<mem1>
[,<mem2>[,<mem3>]]
Responses
+CPMS: (list of supported <mem1>s), (list of supported
<mem2>s), (list of supported <mem3>s)
OK
Responses
+CPMS:<mem1>,<used1>,<total1>,<mem2>,<used2>,<total2>,
<mem3>,<used3>,<total3>
OK
ERROR
+CMS ERROR: <err>
Responses
+CPMS: <used1>,<total1>,<used2>,<total2>,<used3>,<total3>
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
155
2017-12-25
Smart Machine Smart Decision
ERROR
+CMS ERROR: <err>
Responses
Set
default
value
(<mem1>=”SM”,
<mem2>=”SM”,
<mem3>=”SM”):
+CPMS: <used1>,<total1>,<used2>,<total2>,<used3>,<total3>
E
Execution Command
AT+CPMS
FI
L
OK
ERROR
AL
Defined values
C
O
M
C
O
N
FI
D
EN
TI
<mem1>
String type, memory from which messages are read and deleted (commands List Messages
AT+CMGL, Read Message AT+CMGR and Delete Message AT+CMGD).
“ME” and “MT”
FLASH message storage
“SM”
SIM message storage
“SR”
Status report storage (not used in CDMA/EVDO mode)
<mem2>
String type, memory to which writing and sending operations are made (commands Send Message
from Storage AT+CMSS and Write Message to Memory AT+CMGW).
“ME” and “MT”
FLASH message storage
“SM”
SIM message storage
“SR”
Status report storage (not used in CDMA/EVDO mode)
<mem3>
String type, memory to which received SMS is preferred to be stored (unless forwarded directly to
TE; refer command New Message Indications AT+CNMI).
“ME”
FLASH message storage
“SM”
SIM message storage
<usedX>
Integer type, number of messages currently in <memX>.
<totalX>
Integer type, total number of message locations in <memX>.
M
Examples
SI
AT+CPMS=?
+CPMS: ("ME","MT","SM","SR"),("ME","MT","SM","SR"),("ME","SM")
OK
AT+CPMS?
+CPMS:"ME", 0, 23,"ME", 0, 23,"ME", 0, 23
OK
AT+CPMS="SM","SM","SM"
+CPMS:3,50,3,50,3,50
SIM7500_SIM7600 Series_AT Command Manual_V1.07
156
2017-12-25
Smart Machine Smart Decision
OK
7.3
AT+CMGF Select SMS message format
Description
3GPP TS 27.005
Syntax
Responses
+CMGF: (list of supported <mode>s)
TI
Test Command
AT+CMGF=?
ERROR
D
Responses
+CMGF: <mode>
EN
OK
Read Command
AT+CMGF?
AL
YES
References
FI
L
SIM PIN
E
This command is used to specify the input and output format of the short messages.
FI
OK
ERROR
Responses
OK
O
N
Write Command
AT+CMGF=<mode>
ERROR
Responses
Set default value (<mode>=0):
OK
C
M
Execution Command
AT+CMGF
ERROR
O
Defined values
SI
M
C
<mode>
0 – PDU mode
1 – Text mode
Examples
AT+CMGF?
+CMGF: 0
OK
AT+CMGF=?
+CMGF: (0-1)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
157
2017-12-25
Smart Machine Smart Decision
OK
AT+CMGF=1
OK
AT+CSCA SMS service centre address
E
7.4
FI
L
Description
This command is used to update the SMSC address, through which mobile originated SMS are
transmitted.
Note: This command not support in CDMA/EVDO mode
3GPP TS 27.005
TI
YES
References
AL
SIM PIN
EN
Syntax
Responses
OK
Read Command
AT+CSCA?
Responses
+CSCA: <sca>,<tosca>
OK
<sca>
N
C
Defined values
Responses
OK
O
Write Command
AT+CSCA=<sca>[,<tosca>]
FI
D
Test Command
AT+CSCA=?
Service Center Address, value field in string format, BCD numbers (or GSM 7 bit default alphabet
M
C
O
M
characters) are converted to characters of the currently selected TE character set (refer to command
AT+CSCS), type of address given by <tosca>.
<tosca>
SC address Type-of-Address octet in integer format, when first character of <sca> is + (IRA 43)
default is 145, otherwise default is 129.
SI
Examples
AT+CSCA="+8613012345678"
OK
AT+CSCA?
+CSCA: "+8613010314500", 145
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
158
2017-12-25
Smart Machine Smart Decision
7.5
AT+CSCB
Select cell broadcast message indication
Description
SIM PIN
References
3GPP TS 27.005
AL
YES
FI
L
E
The test command returns the supported <mode>s as a compound value.
The read command displays the accepted message types.
Depending on the <mode> parameter, the write command adds or deletes the message types
accepted.
Note: This command not support in CDMA/EVDO mode
TI
Syntax
Responses
+CSCB: (list of supported <mode>s)
OK
EN
Test Command
AT+CSCB=?
D
ERROR
Responses
+CSCB: <mode>,<mids>,<dcss>
OK
FI
Read Command
AT+CSCB?
Responses
OK
O
Write Command
AT+CSCB=<mode>[,<mids
>[,<dcss>]]
N
ERROR
C
ERROR
+CMS ERROR: <err>
M
Defined values
SI
M
C
O
<mode>
0 – message types specified in <mids> and <dcss> are accepted.
1 – message types specified in <mids> and <dcss> are not accepted.
<mids>
String type; all different possible combinations of CBM message identifiers.
<dcss>
String type; all different possible combinations of CBM data coding schemes(default is empty
string)
Examples
AT+CSCB=?
+CSCB: (0-1)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
159
2017-12-25
Smart Machine Smart Decision
OK
AT+CSCB=0,”15-17,50,86”,””
OK
AT+CSMP Set text mode parameters
E
7.6
FI
L
Description
This command is used to select values for additional parameters needed when SM is sent to the
network or placed in storage when text format message mode is selected.
Note: This command not support in CDMA/EVDO mode
3GPP TS 27.005
TI
YES
References
AL
SIM PIN
EN
Syntax
Responses
OK
Read Command
AT+CSMP?
Responses
+CSMP: <fo>,<vp>,<pid>,<dcs>
OK
N
Responses
OK
Defined values
C
O
Write Command
AT+CSMP=[<fo>[,<vp>[,<p
id>[,<dcs>]]]]
FI
D
Test Command
AT+CSMP=?
SI
M
C
O
M
<fo>
Depending on the Command or result code: first octet of GSM 03.40 SMS-DELIVER,
SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer
format. SMS status report is supported under text mode if <fo> is set to 49.
<vp>
Depending on SMS-SUBMIT <fo> setting: GSM 03.40,TP-Validity-Period either in integer format
(default 167), in time-string format, or if is supported, in enhanced format (hexadecimal coded
string with quotes), (<vp> is in range 0... 255).
<pid>
GSM 03.40 TP-Protocol-Identifier in integer format (default 0).
<dcs>
GSM 03.38 SMS Data Coding Scheme (default 0), or Cell Broadcast Data Coding Scheme in
integer format depending on the command or result code.
Examples
SIM7500_SIM7600 Series_AT Command Manual_V1.07
160
2017-12-25
Smart Machine Smart Decision
AT+CSMP=17,23,64,244
OK
7.7
AT+CSDH Show text mode parameters
E
Description
SIM PIN
References
3GPP TS 27.005
AL
YES
FI
L
This command is used to control whether detailed header information is shown in text mode result
codes.
Note: This command not support in CDMA/EVDO mode
TI
Syntax
Responses
+CSDH: (list of supported <show>s)
EN
Test Command
AT+CSDH=?
ERROR
Responses
+CSDH: <show>
N
OK
FI
Read Command
AT+CSDH?
D
OK
Responses
OK
O
Write Command
AT+CSDH=<show>
Responses
Set default value (<show>=0):
OK
ERROR
O
M
Execution Command
AT+CSDH
C
ERROR
C
Defined values
SI
M
<show>
0 – do not show header values defined in commands AT+CSCA and AT+CSMP (<sca>,
<tosca>, <fo>, <vp>, <pid> and <dcs>) nor <length>, <toda> or <tooa> in +CMT,
AT+CMGL, AT+CMGR result codes for SMS-DELIVERs and SMS-SUBMITs in text
mode; for SMS-COMMANDs in AT+CMGR result code, do not show <pid>, <mn>,
<da>, <toda>, <length> or <data>
1 – show the values in result codes
Examples
SIM7500_SIM7600 Series_AT Command Manual_V1.07
161
2017-12-25
Smart Machine Smart Decision
AT+CNMA New message acknowledgement to ME/TA
Description
FI
L
7.8
E
AT+CSDH?
+CSDH: 0
OK
AT+CSDH=1
OK
SIM PIN
References
FI
3GPP TS 27.005
N
YES
D
EN
TI
AL
This command is used to confirm successful receipt of a new message (SMS-DELIVER or
SMS-STATUSREPORT) routed directly to the TE. If ME does not receive acknowledgement within
required time (network timeout), it will send RP-ERROR to the network.
NOTE: The execute / write command shall only be used when AT+CSMS parameter <service>
equals 1 (= phase 2+) and appropriate URC has been issued by the module, i.e.:
<+CMT> for <mt>=2 incoming message classes 0, 1, 3 and none;
<+CMT> for <mt>=3 incoming message classes 0 and 3;
<+CDS> for <ds>=1.
Note: This command not support in CDMA/EVDO mode
M
C
O
Write Command
AT+CNMA=<n>
SI
Execution Command
AT+CNMA
Responses
if text mode(AT+CMGF=1):
OK
if PDU mode (AT+CMGF=0):
+CNMA: (list of supported <n>s)
C
M
Test Command
AT+CNMA=?
O
Syntax
OK
Responses
OK
ERROR
+CMS ERROR: <err>
Responses
OK
ERROR
+CMS ERROR: <err>
Defined values
<n>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
162
2017-12-25
Smart Machine Smart Decision
E
Parameter required only for PDU mode.
0 – Command operates similarly as execution command in text mode.
1 – Send positive (RP-ACK) acknowledgement to the network. Accepted only in PDU
mode.
2 – Send negative (RP-ERROR) acknowledgement to the network. Accepted only in PDU
mode.
AT+CNMI
AL
New message indications to TE
FI
7.9
D
EN
TI
AT+CNMI=1,2,0,0,0
OK
+CMT:”1380022xxxx”,””,”02/04/03,11 :06 :38+32”<CR><LF>
Testing
(receive new short message)
AT+CNMA(send ACK to the network)
OK
AT+CNMA
+CMS ERROR:340
(the second time return error, it needs ACK only once)
FI
L
Examples
N
Description
C
O
This command is used to select the procedure how receiving of new messages from the network is
indicated to the TE when TE is active, e.g. DTR signal is ON. If TE is inactive (e.g. DTR signal is
OFF). If set <mt>=3 or <ds>=1, make sure <mode>=1, If set <mt>=2,make sure <mode>=1 or
2, otherwise it will return error.
3GPP TS 27.005
O
YES
References
M
SIM PIN
C
Syntax
SI
M
Test Command
AT+CNMI=?
Read Command
AT+CNMI?
Responses
+CNMI: (list of supported <mode>s),(list of supported <mt>s),(list
of supported <bm>s),(list of supported <ds>s),(list of supported
<bfr>s)
OK
Responses
+CNMI: <mode>,<mt>,<bm>,<ds>,<bfr>
OK
Write Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
163
2017-12-25
Smart Machine Smart Decision
AT+CNMI=<mode>[,<mt>[,
<bm>[,<ds> [,<bfr>]]]]
OK
ERROR
+CMS ERROR: <err>
E
Responses
Set default value:
OK
FI
L
Execution Command
AT+CNMI
Defined values
–
AL
2
TI
–
D
1
Buffer unsolicited result codes in the TA. If TA result code buffer is full, indications
can be buffered in some other place or the oldest indications may be discarded and
replaced with the new received indications.
Discard indication and reject new received message unsolicited result codes when
TA-TE link is reserved (e.g. in on-line data mode). Otherwise forward them directly
to the TE.
Buffer unsolicited result codes in the TA when TA-TE link is reserved (e.g. in on-line
data mode) and flush them to the TE after reservation. Otherwise forward them
directly to the TE.
EN
<mode>
0
–
SI
M
C
O
M
C
O
N
FI
<mt>
The rules for storing received SMS depend on its data coding scheme, preferred memory storage
(AT+CPMS) setting and this value:
0
– No SMS-DELIVER indications are routed to the TE.
1
– If SMS-DELIVER is stored into ME/TA, indication of the memory location is routed
to the TE using unsolicited result code: +CMTI: <mem3>,<index>.
2
– SMS-DELIVERs (except class 2 messages and messages in the message waiting
indication group (store message)) are routed directly to the TE using unsolicited
result code:
+CMT:[<alpha>],<length><CR><LF><pdu> (PDU mode enabled); or
+CMT:<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>,<sca>,<tosca>,<length>]
<CR> <LF><data>
(text mode enabled, about parameters in italics, refer command Show Text Mode
Parameters AT+CSDH).
3
– Class 3 SMS-DELIVERs are routed directly to TE using unsolicited result codes
defined in <mt>=2. Messages of other data coding schemes result in indication as
defined in <mt>=1.
<bm> (not used in CDMA/EVDO mode)
The rules for storing received CBMs depend on its data coding scheme, the setting of Select CBM
Types (AT+CSCB) and this value:
0 – No CBM indications are routed to the TE.
2 – New CBMs are routed directly to the TE using unsolicited result code:
+CBM: <length><CR><LF><pdu> (PDU mode enabled); or
SIM7500_SIM7600 Series_AT Command Manual_V1.07
164
2017-12-25
Smart Machine Smart Decision
TI
AL
FI
L
E
+CBM: <sn>,<mid>,<dcs>,<page>,<pages><CR><LF><data> (text mode enabled)
<ds> (not used in CDMA/EVDO mode)
0 – No SMS-STATUS-REPORTs are routed to the TE.
1 – SMS-STATUS-REPORTs are routed to the TE using unsolicited result code:
+CDS: <length><CR><LF><pdu> (PDU mode enabled); or
+CDS: <fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st> (text mode enabled)
2 – If SMS-STATUS-REPORT is stored into ME/TA, indication of the memory location is
routed to the TE using unsolicited result code: +CDSI: <mem3>,<index>.
<bfr>
0 – TA buffer of unsolicited result codes defined within this command is flushed to the TE
when <mode> 1 to 3 is entered (OK response shall be given before flushing the codes).
1 – TA buffer of unsolicited result codes defined within this command is cleared when
<mode> 1 to 3 is entered.
Examples
AT+CGSMS Select service for MO SMS messages
C
7.10
O
N
FI
D
EN
AT+CNMI?
+CNMI: 0,0,0,0,0
OK
AT+CNMI=?
+CNMI: (0,1,2),(0,1,2,3),(0,2),(0,1,2),(0,1)
OK
AT+CNMI=2,1 (unsolicited result codes after received messages.)
OK
Description
M
C
O
M
The write command is used to specify the service or service preference that the MT will use to send
MO SMS messages.
The test command is used for requesting information on which services and service preferences can
be set by using the AT+CGSMS write command
The read command returns the currently selected service or service preference.
Note: This command not support in CDMA/EVDO mode
SIM PIN
SI
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+CGSMS=?
Responses
+CGSMS: (list of supported <service>s)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
165
2017-12-25
Smart Machine Smart Decision
Read Command
Responses
AT+CGSMS?
+CGSMS: <service>
OK
Write Command
Responses
AT+CGSMS=<service>
OK
E
ERROR
FI
L
+CME ERROR: <err>
Defined values
EN
TI
AL
<service>
A numeric parameter which indicates the service or service preference to be used
0 – GPRS(value is not really supported and is internally mapped to 2)
1 – circuit switched(value is not really supported and is internally mapped to 3)
2 – GPRS preferred (use circuit switched if GPRS not available)
3 – circuit switched preferred (use GPRS if circuit switched not available)
D
Examples
N
O
C
7.11
FI
AT+CGSMS?
+CGSMS: 3
OK
AT+CGSMS=?
+CGSMS: (0-3)
OK
AT+CMGL List SMS messages from preferred store
M
Description
C
O
This command is used to return messages with status value <stat> from message storage <mem1>
to the TE.
If the status of the message is 'received unread', the status in the storage changes to 'received read'.
M
SIM PIN
3GPP TS 27.005
SI
YES
References
Syntax
Test Command
AT+CMGL=?
Responses
+CMGL: (list of supported <stat>s)
OK
Write Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
166
2017-12-25
Smart Machine Smart Decision
If text mode (AT+CMGF=1), command successful and SMS-S
UBMITs and/or SMS-DELIVERs:
+CMGL:<index>,<stat>,<oa>/<da>,[<alpha>],[<scts>][,<tooa>/<t
oda>,<fo>,<pid>,<dcs>,<sca>,<tosca>,<length>]<CR><LF><data
>[<CR><LF>
AT+CMGL=<stat>
FI
L
E
+CMGL:<index>,<stat>,<oa>/<da>,[<alpha>],[<scts>][,<tooa>/<t
oda>,<fo>,<pid>,<dcs>,<sca>,<tosca>,<length>]<CR><LF><data
>[...]]
OK
AL
If text mode (AT+CMGF=1), command successful and SMSSTATUS-REPORTs:
+CMGL:<index>,<stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<s
t>[<CR><LF>
TI
+CMGL:<index>,<stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<s
t>[...]]
EN
OK
D
If text mode (AT+CMGF=1), command successful and SMSCOMMANDs:
+CMGL: <index>,<stat>,<fo>,<ct>[<CR><LF>
OK
FI
+CMGL: <index>,<stat>,<fo>,<ct>[...]]
O
N
If text mode (AT+CMGF=1), command successful and CBM
storage:
+CMGL:<index>,<stat>,<sn>,<mid>,<page>,<pages>
C
<CR><LF><data>[<CR><LF>
+CMGL:<index>,<stat>,<sn>,<mid>,<page>,<pages>
SI
M
C
O
M
<CR><LF><data>[...]]
OK
If PDU mode (AT+CMGF=0) and Command successful:
+CMGL:<index>,<stat>,[<alpha>],<length><CR><LF><pdu>[<C
R><LF>
+CMGL:<index>,<stat>,[<alpha>],<length><CR><LF><pdu>
[…]]
OK
+CMS ERROR: <err>
Defined values
<stat>
1. Text Mode:
"REC UNREAD" received unread message (i.e. new message)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
167
2017-12-25
Smart Machine Smart Decision
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
"REC READ"
received read message
"STO UNSENT" stored unsent message
"STO SENT"
stored sent message
"ALL"
all messages
2. PDU Mode:
0 – received unread message (i.e. new message)
1 – received read message
2 – stored unsent message
3 – stored sent message
4 – all messages
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <tooa>.
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<alpha>
String type alphanumeric representation of <da> or <oa> corresponding to the entry found in MT
phonebook; implementation of this feature is manufacturer specific; used character set should be
the one selected with command Select TE Character Set AT+CSCS.
<scts>
TP-Service-Centre-Time-Stamp in time-string format (refer <dt>).
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda>).
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length>
Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body
<data> in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP data unit in
octets. (i.e. the RP layer SMSC address octets are not counted in the length)
<data>
In the case of SMS: TP-User-Data in text mode responses; format:
1. If <dcs> indicates that GSM 7 bit default alphabet is used and <fo> indicates that
TP-User-Data-Header-Indication is not set:
a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current TE
character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit character of GSM 7 bit
SIM7500_SIM7600 Series_AT Command Manual_V1.07
168
2017-12-25
Smart Machine Smart Decision
AL
FI
L
E
default alphabet into two IRA character long hexadecimal numbers. (e.g. character Π
(GSM 7 bit default alphabet 23) is presented as 17 (IRA 49 and 55))
2. If <dcs> indicates that 8-bit or UCS2 data coding scheme is used, or <fo> indicates that
TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA
character long hexadecimal numbers. (e.g. octet with integer value 42 is presented to TE as
two characters 2A (IRA 50 and 65))
3. If <dcs> indicates that GSM 7 bit default alphabet is used:
a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current TE
character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7 bit
default alphabet into two IRA character long hexadecimal numbers.
4. If <dcs> indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each
8-bit octet into two IRA character long hexadecimal numbers.
SI
M
C
O
M
C
O
N
FI
D
EN
TI
<fo>
Depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER,
SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer
format. SMS status report is supported under text mode if <fo> is set to 49.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<ra>
Recipient Address
GSM 03.40 TP-Recipient-Address Address-Value field in string format;BCD numbers (or GSM
default alphabet characters) are converted to characters of the currently selected TE character
set(refer to command AT+CSCS);type of address given by <tora>
<tora>
Type of Recipient Address
GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda>)
<dt>
Discharge Time
GSM 03.40 TP-Discharge-Time in time-string format:”yy/MM/dd,hh:mm:ss+zz”,where characters
indicate year (two last digits),month,day,hour,minutes,seconds and time zone.
<st>
Status
GSM 03.40 TP-Status in integer format
0…255
<ct>
Command Type
GSM 03.40 TP-Command-Type in integer format
0…255
<sn>
Serial Number
GSM 03.41 CBM Serial Number in integer format
SIM7500_SIM7600 Series_AT Command Manual_V1.07
169
2017-12-25
Smart Machine Smart Decision
TI
AL
FI
L
E
<mid>
Message Identifier
GSM 03.41 CBM Message Identifier in integer format
<page>
Page Parameter
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
<pages>
Page Parameter
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
<pdu>
In the case of SMS: SC address followed by TPDU in hexadecimal format: ME/TA converts each
octet of TP data unit into two IRA character long hexadecimal numbers. (e.g. octet with integer
value 42 is presented to TE as two characters 2A (IRA 50 and 65)).
Examples
O
AT+CMGR Read message
C
7.12
N
FI
D
EN
AT+CMGL=?
+CMGL: ("REC UNREAD","REC READ","STO UNSENT","STO SENT","ALL")
OK
AT+CMGL="ALL"
+CMGL: 1,"STO UNSENT","+10011",,,145,4
Hello World
OK
Description
M
This command is used to return message with location value <index> from message storage
<mem1> to the TE.
References
O
SIM PIN
3GPP TS 27.005
C
YES
M
Syntax
Responses
OK
Write Command
AT+CMGR=<index>
Responses
If text mode (AT+CMGF=1), command successful and SMSDELIVER:
+CMGR: <stat>,<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>,
<sca>, <tosca>, <length>]<CR><LF><data>
SI
Test Command
AT+CMGR=?
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
170
2017-12-25
Smart Machine Smart Decision
If text mode (AT+CMGF=1), command successful and SMSSUBMIT:
+CMGR:<stat>,<da>,[<alpha>][,<toda>,<fo>,<pid>,<dcs>,[<vp>],
<sca>, <tosca>,<length>]<CR><LF><data>
OK
FI
L
E
If text mode (AT+CMGF=1), command successful and SMSSTATUS-REPORT:
+CMGR: <stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st>
OK
AL
If text mode (AT+CMGF=1), command successful and SMSCOMMAND:
+CMGR:<stat>,<fo>,<ct>[,<pid>,[<mn>],[<da>],[<toda>],<length
>]<CR><LF><data>
TI
OK
D
EN
If text mode (AT+CMGF=1), command successful and CBM
storage:
+CMGR:<stat>,<sn>,<mid>,<dcs>,<page>,<pages><CR><LF><d
ata>
OK
N
FI
If PDU mode (AT+CMGF=0) and Command successful:
+CMGR:<stat>,[<alpha>],<length><CR><LF><pdu>
OK
C
Defined values
O
+CMS ERROR: <err>
SI
M
C
O
M
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<stat>
1.Text Mode:
"REC UNREAD" received unread message (i.e. new message)
"REC READ"
received read message
"STO UNSENT" stored unsent message
"STO SENT"
stored sent message
2. PDU Mode:
0 – received unread message (i.e. new message)
1 – received read message.
2 – stored unsent message.
3 – stored sent message
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
SIM7500_SIM7600 Series_AT Command Manual_V1.07
171
2017-12-25
Smart Machine Smart Decision
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <tooa>.
<alpha>
String type alphanumeric representation of <da> or <oa> corresponding to the entry found in MT
phonebook; implementation of this feature is manufacturer specific; used character set should be
the one selected with command Select TE Character Set AT+CSCS.
<scts>
TP-Service-Centre-Time-Stamp in time-string format (refer <dt>).
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda>).
<fo>
Depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER,
SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer
format. SMS status report is supported under text mode if <fo> is set to 49.
<pid>
Protocol Identifier
GSM 03.40 TP-Protocol-Identifier in integer format
0…255
<dcs>
Depending on the command or result code: SMS Data Coding Scheme (default 0), or Cell
Broadcast Data Coding Scheme in integer format.
<sca>
RP SC address Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet
characters) are converted to characters of the currently selected TE character set, type of address
given by <tosca>.
<tosca>
RP SC address Type-of-Address octet in integer format (default refer <toda>).
<length>
Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP
data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length).
<data>
In the case of SMS: TP-User-Data in text mode responses; format:
1 – If <dcs> indicates that GSM 7 bit default alphabet is used and <fo> indicates that
TP-User-Data-Header-Indication is not set:
a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current
TE character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit character of GSM 7 bit
default alphabet into two IRA character long hexadecimal numbers. (e.g. character
2
Π (GSM 7 bit default alphabet 23) is presented as 17 (IRA 49 and 55)).
– If <dcs> indicates that 8-bit or UCS2 data coding scheme is used, or <fo> indicates that
TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA
character long hexadecimal numbers. (eg. octet with integer value 42 is presented to TE
SIM7500_SIM7600 Series_AT Command Manual_V1.07
172
2017-12-25
Smart Machine Smart Decision
FI
L
4
E
3
as two characters 2A (IRA 50 and 65)).
– If <dcs> indicates that GSM 7 bit default alphabet is used:
a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current
TE character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7
bit default alphabet into two IRA character long hexadecimal numbers.
– If <dcs> indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts
each 8-bit octet into two IRA character long hexadecimal numbers.
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<vp>
Depending on SMS-SUBMIT <fo> setting: TP-Validity-Period either in integer format (default
167) or in time-string format (refer <dt>).
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<ra>
Recipient Address
GSM 03.40 TP-Recipient-Address Address-Value field in string format;BCD numbers(or GSM
default alphabet characters) are converted to characters of the currently selected TE character
set(refer to command AT+CSCS);type of address given by <tora>
<tora>
Type of Recipient Address
GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda>)
<dt>
Discharge Time
GSM 03.40 TP-Discharge-Time in time-string format:”yy/MM/dd,hh:mm:ss+zz”,where characters
indicate year (two last digits),month,day,hour,minutes,seconds and time zone.
<st>
Status
GSM 03.40 TP-Status in integer format
0…255
<ct>
Command Type
GSM 03.40 TP-Command-Type in integer format
0…255
<mn>
Message Number
SIM7500_SIM7600 Series_AT Command Manual_V1.07
173
2017-12-25
Smart Machine Smart Decision
EN
TI
AL
FI
L
E
GSM 03.40 TP-Message-Number in integer format
<sn>
Serial Number
GSM 03.41 CBM Serial Number in integer format
<mid>
Message Identifier
GSM 03.41 CBM Message Identifier in integer format
<page>
Page Parameter
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
<pages>
Page parameter
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
<pdu>
In the case of SMS: SC address followed by TPDU in hexadecimal format: ME/TA converts each
octet of TP data unit into two IRA character long hexadecimal numbers. (eg. octet with integer
value 42 is presented to TE as two characters 2A (IRA 50 and 65)).
D
Examples
AT+CMGS Send message
C
7.13
O
N
FI
AT+CMGR=1
+CMGR: "STO UNSENT","+10011",,145,17,0,0,167,"+8613800100500",145,11
Hello World
OK
Description
M
This command is used to send message from a TE to the network (SMS-SUBMIT).
References
O
SIM PIN
3GPP TS 27.005
C
YES
M
Syntax
Responses
OK
Write Command
If text mode (AT+CMGF=1):
AT+CMGS=<da>[,<toda>]<
CR>Text is entered.
<CTRL-Z/ESC>
Responses
If sending successfully:
SI
Test Command
AT+CMGS=?
+CMGS: <mr>
OK
If cancel sending:
SIM7500_SIM7600 Series_AT Command Manual_V1.07
174
2017-12-25
Smart Machine Smart Decision
OK
If sending fails:
ERROR
If sending fails:
+CMS ERROR: <err>
E
If PDU mode(AT+CMGF=
0):
AT+CMGS=<length><CR>
PDU is entered
<CTRL-Z/ESC>
FI
L
Defined values
O
N
FI
D
EN
TI
AL
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length>
integer type value indicating in the text mode (AT+CMGF=1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP
data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length)
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
C
Examples
AT+CMSS Send message from storage
M
C
7.14
O
M
AT+CMGS="13012832788"<CR>(TEXT MODE)
> ABCD<ctrl-Z/ESC>
+CMGS: 46
OK
SI
Description
This command is used to send message with location value <index> from preferred message
storage <mem2> to the network (SMS-SUBMIT or SMS-COMMAND).
SIM PIN
YES
References
3GPP TS 27.005
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
175
2017-12-25
Smart Machine Smart Decision
Test Command
Responses
AT+CMSS=?
OK
Write Command
Responses
AT+CMSS=
<index> [,<da>[,<toda>]]
+CMSS: <mr>
E
OK
ERROR
FI
L
If sending fails:
+CMS ERROR: <err>
AL
Defined values
Examples
M
C
O
N
FI
D
EN
TI
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
SI
M
C
O
AT+CMSS=3
+CMSS: 0
OK
AT+CMSS=3,"13012345678"
+CMSS: 55
OK
7.15
AT+CMGW Write message to memory
Description
This command is used to store message (either SMS-DELIVER or SMS-SUBMIT) to memory
storage <mem2>.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
176
2017-12-25
Smart Machine Smart Decision
SIM PIN
YES
References
3GPP TS 27.005
Syntax
Responses
OK
Write Command
If text mode(AT+CMGF=1):
AT+CMGW=<oa>/<da>[,<t
ooa>/<toda>[,<stat>]]<CR>
Text is entered.
<CTRL-Z/ESC>
If PDU mode(AT+CMGF=
0):
AT+CMGW=<length>[,<sta
t>]<CR>PDU is entered.
<CTRL-Z/ESC>
Responses
If write successfully:
FI
L
E
Test Command
AT+CMGW=?
+CMGW: <index>
AL
OK
If cancel write:
TI
OK
If write fails:
EN
ERROR
If write fails:
FI
D
+CMS ERROR: <err>
N
Defined values
SI
M
C
O
M
C
O
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <tooa>.
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda>).
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length>
Integer type value indicating in the text mode (AT+CMGF=1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode (AT+CMGF=0), the length of the actual TP
data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length).
<stat>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
177
2017-12-25
Smart Machine Smart Decision
FI
L
E
1. Text Mode:
"STO UNSENT" stored unsent message
"STO SENT"
stored sent message
2. PDU Mode:
2 – stored unsent message
3 – stored sent message
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
AT+CMGD Delete message
D
Description
TI
EN
7.16
AL
AT+CMGW="13012832788" <CR> (TEXT MODE)
ABCD<ctrl-Z/ESC>
+CMGW:1
OK
SIM PIN
3GPP TS 27.005
C
O
YES
References
N
FI
This command is used to delete message from preferred message storage <mem1> location
<index>. If <delflag> is present and not set to 0 then the ME shall ignore <index> and follow the
rules for <delflag> shown below.
Syntax
Responses
+CMGD: (list
<delflag>s)]
OK
Write Command
Responses
AT+CMGD=
<index>[,<delflag>]
OK
SI
M
C
O
M
Test Command
AT+CMGD=?
of
supported
<index>s)[,(list
of
supported
ERROR
+CMS ERROR: <err>
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<delflag>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
178
2017-12-25
Smart Machine Smart Decision
– (or omitted) Delete the message specified in <index>.
– Delete all read messages from preferred message storage, leaving unread messages and
stored mobile originated messages (whether sent or not) untouched.
2 – Delete all read messages from preferred message storage and sent mobile originated
messages, leaving unread messages and unsent mobile originated messages untouched.
3 – Delete all read messages from preferred message storage, sent and unsent mobile
originated messages leaving unread messages untouched.
4 – Delete all messages from preferred message storage including unread messages.
NOTE: If set <delflag>=1, 2, 3 or 4, <index> is omitted, such as AT+CMGD=,1.
FI
L
E
0
1
AL
Examples
AT+CMGMT Change message status
EN
7.17
TI
AT+CMGD=1
OK
Description
Vendor
Syntax
M
Test Command
AT+CMGMT=?
C
O
YES
References
N
SIM PIN
FI
D
This command is used to change the message status. If the status is unread, it will be changed read.
Other statuses don’t change.
Note: This command not support in CDMA/EVDO mode
Responses
OK
ERROR
+CMS ERROR: <err>
M
C
O
Write Command
AT+CMGMT=<index>
Responses
OK
SI
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
Examples
AT+CMGMT=1
SIM7500_SIM7600 Series_AT Command Manual_V1.07
179
2017-12-25
Smart Machine Smart Decision
OK
7.18
AT+CMVP Set message valid period
Description
References
Vendor
Syntax
Responses
+CMVP: (list of supported <vp>s)
TI
Test Command
AT+CMVP=?
EN
OK
Responses
+CMVP:<vp>
OK
Responses
OK
FI
Write Command
AT+CMVP=<vp>
D
Read Command
AT+CMVP?
AL
YES
FI
L
SIM PIN
E
This command is used to set valid period for sending short message.
Note: This command not support in CDMA/EVDO mode
N
ERROR
C
Defined values
O
+CMS ERROR: <err>
SI
M
C
O
M
<vp>
Validity period value:
0 to 143
(<vp>+1) x 5 minutes (up to 12 hours)
144 to 167
12 hours + (<vp>-143) x 30 minutes
168 to 196
(<vp>-166) x 1 day
197 to 255
(<vp>-192) x 1 week
Examples
AT+CMVP=167
OK
AT+CMVP?
+CMVP: 167
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
180
2017-12-25
Smart Machine Smart Decision
7.19
AT+CMGRD
Read and delete message
Description
YES
References
FI
L
SIM PIN
E
This command is used to read message, and delete the message at the same time. It integrate
AT+CMGR and AT+CMGD, but it doesn’t change the message status.
Note: This command not support in CDMA/EVDO mode
Vendor
AL
Syntax
Responses
OK
Write Command
AT+CMGRD=<index>
Responses
If text mode(AT+CMGF=1),command successful and SMS-DELIVER:
+CMGRD:<stat>,<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs
>, <sca>,<tosca>,<length>]<CR><LF><data>
FI
OK
D
EN
TI
Test Command
AT+CMGRD=?
O
N
If text mode(AT+CMGF=1),command successful and SMS-SUBMIT:
+CMGRD:<stat>,<da>,[<alpha>][,<toda>,<fo>,<pid>,<dcs>,[<vp
>], <sca>,<tosca>,<length>]<CR><LF><data>
SI
M
C
O
M
C
OK
If text mode(AT+CMGF=1),command successful and SMS-STATUS- REPORT:
+CMGRD: <stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st>
OK
If text mode(AT+CMGF=1),command successful and SMS-COMMAND:
+CMGRD:<stat>,<fo>,<ct>[,<pid>,[<mn>],[<da>],[<toda>],<lengt
h><CR><LF><data>]
OK
If text mode(AT+CMGF=1),command successful and CBM storage:
+CMGRD:<stat>,<sn>,<mid>,<dcs>,<page>,<pages><CR><LF><
data>
OK
If PDU mode(AT+CMGF=0) and command successful:
+CMGRD: <stat>,[<alpha>],<length><CR><LF><pdu>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
181
2017-12-25
Smart Machine Smart Decision
OK
ERROR
+CMS ERROR: <err>
E
Defined values
FI
L
Refer to command AT+CMGR.
Examples
7.20
EN
TI
AL
AT+CMGRD=6
+CMGRD:"REC READ","+8613917787249",,"06/07/10,12:09:38+32",145,4,0,0, "+86138002105
00",145,4
How do you do
OK
AT+CMGSEX Send message
D
Description
3GPP TS 27.005
O
YES
References
N
SIM PIN
FI
This command is used to send message from a TE to the network (SMS-SUBMIT).
Note: This command not support in CDMA/EVDO mode
C
Syntax
Responses
AT+CMGSEX=?
OK
Write Command
Responses
If text mode (AT+CMGF=1):
AT+CMGSEX=<da>[,<toda
>][,<mr>,
<msg_seg>,
<msg_total>]<CR>Text is
entered.
<CTRL-Z/ESC>
If sending successfully:
SI
M
C
O
M
Test Command
+CMGSEX: <mr>
OK
If cancel sending:
OK
If sending fails:
ERROR
If sending fails:
+CMS ERROR: <err>
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
182
2017-12-25
Smart Machine Smart Decision
EN
TI
AL
FI
L
E
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (When first character of <da> is
+ (IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<msg_seg>
The segment number for long sms
<msg_total>
The total number of the segments for long sms. Its range is from 2 to 255.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: For
single SMS, it is 160 characters if the 7 bit GSM coding scheme is used; For multiple long sms, it is
153 characters if the 7 bit GSM coding scheme is used.
D
Examples
C
O
N
FI
AT+CMGSEX="13012832788", 190, 1, 2<CR>(TEXT MODE)
> ABCD<ctrl-Z/ESC>
+CMGSEX: 190
OK
AT+CMGSEX="13012832788", 190, 2, 2<CR>(TEXT MODE)
> EFGH<ctrl-Z/ESC>
+CMGSEX: 190
OK
M
AT+CMSSEX Send multi messages from storage
O
7.21
Description
SI
M
C
This command is used to send messages with location value <index1>,<index2>,<index3>… from
preferred message storage <mem2> to the network (SMS-SUBMIT or SMS-COMMAND).The
max count of index is 13 one time.
Note: This command not support in CDMA/EVDO mode
SIM PIN
YES
References
3GPP TS 27.005
Syntax
Test Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
183
2017-12-25
Smart Machine Smart Decision
AT+CMSSEX=?
OK
Write Command
Responses
AT+CMSSEX=
<index> [,<index >[,… ]]
+CMSSEX: <mr>[,<mr>[,…]]
OK
E
ERROR
If sending fails:
FI
L
[+CMSSEX: <mr>[,<mr>[,…]]]
+CMS ERROR: <err>
AL
Defined values
FI
D
EN
TI
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
N
Examples
O
AT+CMSSEX=0,1
+CMSSEX: 239,240
AT+CMGP Set cdma/evdo text mode parameters
M
C
7.22
O
M
C
OK
AT+CMSSEX=0,1
+CMSSEX: 238
+CMS ERROR: Invalid memory index
Description
SI
The command is used to select values for additional parameters needed when SM is sent to the
network or placed in storage when text format message mode is selected.
NOTE: take effect in CDMA/EVDO mode
SIM PIN
NO
References
3GPP TS 27.005
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
184
2017-12-25
Smart Machine Smart Decision
Test Command
AT+CMGP=?
Responses
OK
Read Command
AT+CMGP?
Responses
+CMGP: <tid>,<vpf>,<vp>,<ddtf>,<ddt>
Responses
OK
FI
L
Write Command
AT+CMGP=[Tid][,<vpf>,<v
p>[,<ddtf>,<ddt>]]
E
OK
AL
Defined values
O
M
C
O
N
FI
D
EN
TI
<tid>
Teleservice ID, value maybe 4095,4096,4097,4098,4099,4100,4101,4102
Default 4098
<vpf>
Valid Period Format
0, Absolute
1, Relative
<vp>
Valid Period
“YY/MM/DD,HH/MM/SS” if vpf=0,
Integer not exceed 248 if vpf=1
<ddtf>
Deferred Delivery Time Format
0, Absolute
1, Relative
<ddt>
Deferred Delivery Time
“YY/MM/DD,HH/MM/SS” if ddtf=0,
Integer not exceed 248 if ddtf=1
C
Examples
SI
M
AT+CMGP=4098,0,”11/04/22,16:21:00”,1,12
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
185
2017-12-25
8
AT+CPBS Select phonebook memory storage
E
8.1
AT Commands for Phonebook
FI
L
Description
This command selects the active phonebook storage,i.e.the phonebook storage that all subsequent
phonebook commands will be operating on.
3GPP TS 27.007
TI
YES
References
AL
SIM PIN
EN
Syntax
Responses
+CPBS: (list of supported <storage>s)
OK
Read Command
AT+CPBS?
Responses
FI
D
Test Command
AT+CPBS=?
+CPBS: <storage>[,<used>,<total>]
N
OK
Responses
OK
C
Write Command
AT+CPBS=<storage>
O
+CME ERROR: <err>
ERROR
M
+CME ERROR: <err>
Responses
AT+CPBS
Set default value “SM”:
OK
C
O
Execution Command
M
Defined values
SI
<storage>
Values reserved by the present document:
"DC"
ME dialed calls list
Capacity: max. 100 entries
AT+CPBW command is not applicable to this storage.
"MC"
ME missed (unanswered received) calls list
Capacity: max. 100 entries
AT+CPBW command is not applicable to this storage.
"FD"
"ON"
"LD"
EN
"EN"
FI
L
"ME"
AL
"SM"
ME received calls list
Capacity: max. 100 entries
AT+CPBW command is not applicable to this storage.
SIM phonebook
Capacity: depending on SIM card
Mobile Equipment phonebook
Capacity: max. 500 entries
SIM fixdialling-phonebook
Capacity:depending on SIM card
MSISDN list
Capacity:depending on SIM card
Last number dialed phonebook
Capacity: depending on SIM card
AT+CPBW command is not applicable to this storage
Emergency numbers
Capacity: depending on SIM card
AT+CPBW command is not applicable to this storage.
TI
"RC"
E
Smart Machine Smart Decision
FI
D
<used>
Integer type value indicating the number of used locations in selected memory.
<total>
Integer type value indicating the total number of locations in selected memory.
N
Examples
AT+CPBR Read phonebook entries
M
8.2
C
O
M
C
O
AT+CPBS=?
+CPBS: ("SM","DC","FD","LD","MC","ME","RC","EN","ON")
OK
AT+CPBS=”SM”
OK
AT+CPBS?
+CPBS: "SM",1,200
OK
SI
Description
This command gets the record information from the selected memory storage in phonebook. If the
storage is selected as “SM” then the command will return the record in SIM phonebook, the same to
others.
SIM PIN
YES
References
3GPP TS 27.007
SIM7500_SIM7600 Series_AT Command Manual_V1.07
187
2017-12-25
Smart Machine Smart Decision
Syntax
Test Command
AT+CPBR=?
Responses
+CPBR: (<minIndex>-<maxIndex>), [<nlength>], [<tlength>]
OK
Responses
FI
L
Write Command
AT+CPBR=
<index1>[,<index2>]
E
+CME ERROR: <err>
[+CPBR: <index1>,<number>,<type>,<text>[<CR><LF>
+CPBR: <index2>,<number>,<type>,<text>[…]]]
AL
OK
ERROR
TI
+CME ERROR: <err>
EN
Defined values
SI
M
C
O
M
C
O
N
FI
D
<index1>
Integer type value in the range of location numbers of phonebook memory.
<index2>
Integer type value in the range of location numbers of phonebook memory.
<index>
Integer type.the current position number of the Phonebook index.
<minIndex>
Integer type the minimum <index> number.
<maxIndex>
Integer type the maximum <index> number
<number>
String type, phone number of format <type>, the maximum length is <nlength>.
<type>
Type of phone number octet in integer format, default 145 when dialing string includes international
access code character "+", otherwise 129.
<text>
String type field of maximum length <tlength>; often this value is set as name.
<nlength>
Integer type value indicating the maximum length of field <number>.
<tlength>
Integer type value indicating the maximum length of field <text>.
Examples
AT+CPBS?
+CPBS: "SM",2,200
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
188
2017-12-25
Smart Machine Smart Decision
AT+CPBR=1,10
+CPBR: 1,"1234567890",129,"James"
+CPBR: 2,"0987654321",129,"Kevin"
OK
E
AT+CPBF Find phonebook entries
FI
L
8.3
Description
SIM PIN
References
3GPP TS 27.007
TI
YES
AL
This command finds the record in phonebook (from the current phonebook memory storage
selected with AT+CPBS) which alphanumeric field has substring <findtext>.If <findtext> is null, it
will lists all the entries.
Test Command
AT+CPBF=?
EN
Syntax
Responses
FI
OK
D
+CPBF: [<nlength>],[<tlength>]
+CME ERROR: <err>
N
Responses
[+CPBF: <index1>,<number>,<type>,<text>[<CR><LF>
O
Write Command
AT+CPBF=[<findtext>]
C
+CPBF: <indexN>,<number>,<type>,<text>[…]]]
OK
M
ERROR
+CME ERROR: <err>
O
Defined values
SI
M
C
<findtext>
String type, this value is used to find the record. Character set should be the one selected with
command AT+CSCS.
<index>
Integer type values in the range of location numbers of phonebook memory.
<number>
String type, phone number of format <type>, the maximum length is <nlength>.
<type>
Type of phone number octet in integer format, default 145 when dialing string includes international
access code character "+", otherwise 129.
<text>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
189
2017-12-25
Smart Machine Smart Decision
E
String type field of maximum length <tlength>; Often this value is set as name.
<nlength>
Integer type value indicating the maximum length of field <number>.
<tlength>
Integer type value indicating the maximum length of field <text>.
FI
L
Examples
AT+CPBW Write phonebook entry
TI
8.4
AL
AT+CPBF=" James "
+CPBF: 1,"1234567890",129," James "
OK
Description
3GPP TS 27.007
FI
YES
References
D
SIM PIN
EN
This command writes phonebook entry in location number <index> in the current phonebook
memory storage selected with AT+CPBS.
N
Syntax
Responses
O
Test Command
AT+CPBW=?
+CPBW:(list of supported <index>s),[<nlength>],
C
(list of supported <type>s),[<tlength>]
OK
M
+CME ERROR:<err>
Responses
OK
ERROR
+CME ERROR:<err>
M
C
O
Write Command
AT+CPBW=[<index>][,<nu
mber>[,<type>[,<text>]]]
SI
Defined values
<index>
Integer type values in the range of location numbers of phonebook memory.If <index> is not given,
the first free entry will be used. If <index> is given as the only parameter, the phonebook entry
specified by <index> is deleted.If record number <index> already exists, it will be overwritten.
<number>
String type, phone number of format <type>, the maximum length is <nlength>.It must be an
non-empty string.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
190
2017-12-25
Smart Machine Smart Decision
FI
L
E
<type>
Type of address octet in integer format, The range of value is from 129 to 255. If <number>
contains a leading “+” <type> = 145 (international) is used.Supported value are:
145 – when dialling string includes international access code character “+”
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
129 – otherwise
D
EN
TI
AL
NOTE: Other value refer TS 24.008 [8] subclause 10.5.4.7.
<text>
String type field of maximum length <tlength>; character set as specified by command Select TE
Character Set AT+CSCS.
<nlength>
Integer type value indicating the maximum length of field <number>.
<tlength>
Integer type value indicating the maximum length of field <text>.
NOTE: If the parameters of <type> and <text> are omitted and the first character of <number> is
‘+’,it will specify <type> as 145(129 if the first character isn’t ‘+’) and <text> as NULL.
C
O
N
AT+CPBW=3,"88888888",129,"John"
OK
AT+CPBW=,”6666666”,129,”mary”
OK
AT+CPBW=1
OK
FI
Examples
AT+CNUM
Subscriber number
M
8.5
O
Description
M
C
Execution command returns the MSISDNs related to the subscriber (this information can be stored
in the SIM or in the ME). If subscriber has different MSISDN for different services, each MSISDN
is returned in a separate line.
SI
SIM PIN
YES
References
3GPP TS 27.007
Syntax
Test Command
AT+CNUM=?
Responses
OK
Execution Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
191
2017-12-25
Smart Machine Smart Decision
AT+CNUM
[+CNUM: <alpha>,<number>,<type>[<CR><LF>
+CNUM: <alpha>, <number>,<type> [...]]]
OK
+CME ERROR: <err>
E
Defined values
TI
AL
FI
L
<alpha>
Optional alphanumeric string associated with <number>, used character set should be the one
selected with command Select TE Character Set AT+CSCS.
<number>
String type phone number of format specified by <type>.
<type>
Type of address octet in integer format.see also AT+CPBR <type>
EN
Examples
SI
M
C
O
M
C
O
N
FI
D
AT+CNUM
+CNUM: "","13697252277",129
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
192
2017-12-25
Smart Machine Smart Decision
9
AT Commands for GPRS
AT+CGREG GPRS network registration status
FI
L
Description
E
9.1
3GPP TS 27.007
EN
NO
References
TI
SIM PIN
AL
This command controls the presentation of an unsolicited result code “+CGREG: <stat>” when
<n>=1 and there is a change in the MT's GPRS network registration status.
The read command returns the status of result code presentation and an integer <stat> which shows
Whether the network has currently indicated the registration of the MT.
Syntax
OK
Responses
+CGREG: <n>,<stat>[,<lac>,<ci>]
N
Read Command
AT+CGREG?
D
Responses
+CGREG: (list of supported <n>s)
FI
Test Command
AT+CGREG=?
C
Responses
OK
Responses
Set default value:
OK
O
M
Write Command
AT+CGREG=<n>
Execution Command
AT+CGREG
O
OK
Defined values
C
<n>
– disable network registration unsolicited result code
– enable network registration unsolicited result code +CGREG: <stat>
– there is a change in the ME network registration status or a change of the network cell:
+CGREG: <stat>[,<lac>,<ci>]
SI
M
0
1
2
<stat>
0 – not registered, ME is not currently searching an operator to register to
1 – registered, home network
2 – not registered, but ME is currently trying to attach or searching an operator to register
to
3 – registration denied
SIM7500_SIM7600 Series_AT Command Manual_V1.07
193
2017-12-25
Smart Machine Smart Decision
4 – unknown
5 – registered, roaming
<lac>
Two bytes location area code in hexadecimal format (e.g.”00C3” equals 193 in decimal).
FI
L
EN
Examples
N
FI
D
AT+CGREG=?
+CGREG: (0-1)
OK
AT+CGREG?
+CGREG: 0,0
OK
O
AT+CGATT Packet domain attach or detach
C
9.2
AL
The <ci> not supported in CDMA/HDR mode
TI
NOTE:
E
NOTE: The <lac> not supported in CDMA/HDR mode
<ci>
Cell ID in hexadecimal format.
GSM : Maximum is two byte
WCDMA : Maximum is four byte
TDS-CDMA : Maximum is four byte
Description
M
The write command is used to attach the MT to, or detach the MT from, the Packet Domain service.
The read command returns the current Packet Domain service state.
References
O
SIM PIN
3GPP TS 27.007
C
YES
M
Syntax
SI
Test Command
AT+CGATT=?
Responses
+CGATT: (list of supported <state>s)
OK
ERROR
Read Command
Responses
AT+CGATT?
+CGATT: <state>
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
194
2017-12-25
Smart Machine Smart Decision
ERROR
Write Command
Responses
AT+CGATT=<state>
OK
ERROR
E
+CME ERROR: <err>
FI
L
Defined values
AL
<state>
Indicates the state of Packet Domain attachment:
0 – detached
1 – attached
TI
Examples
D
FI
AT+CGACT PDP context activate or deactivate
N
9.3
EN
AT+CGATT?
+CGATT: 0
OK
AT+CGATT=1
OK
O
Description
YES
3GPP TS 27.007
O
Syntax
References
M
SIM PIN
C
The write command is used to activate or deactivate the specified PDP context (s). This command is
not used in CDMA/EVDO mode.
Responses
+CGACT: (list of supported <state>s)
OK
Read Command
Responses
AT+CGACT?
+CGACT: [<cid>, <state> [<CR><LF>
+CGACT: <cid>, <state>
[...]]]
OK
Write Command
Responses
AT+CGACT=<state>
OK
SI
M
C
Test Command
AT+CGACT=?
SIM7500_SIM7600 Series_AT Command Manual_V1.07
195
2017-12-25
Smart Machine Smart Decision
[,<cid>]
ERROR
+CME ERROR: <err>
Defined values
TI
AL
FI
L
E
<state>
Indicates the state of PDP context activation:
0 – deactivated
1 – activated
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command).
1…24,100…179
Examples
D
FI
N
O
AT+CGDCONT Define PDP context
C
9.4
EN
AT+CGACT?
+CGACT: 1,1
OK
AT+CGACT=?
+CGACT: (0,1)
OK
AT+CGACT=0,1
OK
Description
C
O
M
The set command specifies PDP context parameter values for a PDP context identified by the
(local) context identification parameter <cid>. The number of PDP contexts that may be in a
defined state at the same time is given by the range returned by the test command. A special form of
the write command (AT+CGDCONT=<cid>) causes the values for context <cid> to become
undefined.
M
SIM PIN
3GPP TS 27.007
SI
YES
References
Syntax
Test Command
Responses
AT+CGDCONT=?
+CGDCONT: (range of supported<cid>s),<PDP_type>,,,(list of
supported <d_comp>s),(list of supported <h_comp>s)(list of
<ipv4_ctrl>s),(list of <emergency_flag>s)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
196
2017-12-25
Smart Machine Smart Decision
OK
ERROR
Responses
AT+CGDCONT?
+CGDCONT: [<cid>, <PDP_type>, <APN>,<PDP_addr>,
<d_comp>, <h_comp>,<ipv4_ctrl>,<emergency_flag>[<CR><LF>
+CGDCONT: <cid>, <PDP_type>, <APN>, <PDP_addr>,
<d_comp>, <h_comp>,< ipv4_ctrl>,<emergency_flag>[...]]]
OK
FI
L
E
Read Command
Responses
AT+CGDCONT=<cid>[,<P
DP_type>[,<APN>[,<PDP_a
ddr>[,<d_comp>[,<h_comp>
][,<ipv4_ctrl>[,<emergency_
flag>]]]]]]
OK
Execution Command
Responses
AT+CGDCONT
OK
TI
Write Command
AL
ERROR
D
N
FI
ERROR
EN
ERROR
O
Defined values
SI
M
C
O
M
C
<cid>
(PDP Context Identifier) a numeric parameter which specifies a particular PDP context definition.
The parameter is local to the TE-MT interface and is used in other PDP context-related commands.
The range of permitted values (minimum value = 1) is returned by the test form of the command.
1…24,100…179
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<APN>
(Access Point Name) a string parameter which is a logical name that is used to select the GGSN or
the external packet data network.
<PDP_addr>
A string parameter that identifies the MT in the address space applicable to the PDP.
Read command will continue to return the null string even if an address has been allocated during
the PDP startup procedure. The allocated address may be read using command AT+CGPADDR.
<d_comp>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
197
2017-12-25
Smart Machine Smart Decision
D
EN
TI
AL
FI
L
E
A numeric parameter that controls PDP data compression, this value may depend on platform:
0 – off (default if value is omitted)
1 – on
2 – V.42bis
<h_comp>
A numeric parameter that controls PDP header compression, this value may depend on platform:
0 – off (default if value is omitted)
1 – on
2 – RFC1144
3 – RFC2507
4 – RFC3095
<ipv4_ctrl>
Parameter that controls how the MT/TA requests to get the IPv4 address information:
0 – Address Allocation through NAS Signaling
1 – on
<emergency_flag>
emergency_flag:
0 – off (default if value is omitted)
1 – on
FI
Examples
C
O
N
AT+CGDCONT?
+CGDCONT: 1,"IPV4V6","","0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0",0,0,0,0
+CGDCONT: 2,"IPV6","ims","0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0",0,0,0,0
+CGDCONT: 3,"IPV4V6","","0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0",0,0,0,1
C
O
M
OK
AT+CGDCONT=?
+CGDCONT: (1-24,100-179),"IP",,,(0-2),(0-4),(0-1),(0-1)
+CGDCONT: (1-24,100-179),"PPP",,,(0-2),(0-4),(0-1),(0-1)
+CGDCONT: (1-24,100-179),"IPV6",,,(0-2),(0-4),(0-1),(0-1)
+CGDCONT: (1-24,100-179),"IPV4V6",,,(0-2),(0-4),(0-1),(0-1)
M
OK
AT+CGDSCONT Define Secondary PDP Context
SI
9.5
Description
The set command specifies PDP context parameter values for a Secondary PDP context identified
by the (local) context identification parameter, <cid>. The number of PDP contexts that may be in a
defined state at the same time is given by the range returned by the test command. A special form of
the set command, AT+CGDSCONT=<cid> causes the values for context number <cid> to become
SIM7500_SIM7600 Series_AT Command Manual_V1.07
198
2017-12-25
Smart Machine Smart Decision
undefined.
SIM PIN
YES
References
3GPP TS 27.007
FI
L
E
Syntax
Responses
AT+CGDSCONT=?
+CGDSCONT: (range of supported <cid>s),(list of <p_cid>s for
active primary contexts), <PDP_type>, (list of supported
<d_comp>s),(list of supported <h_comp>s)
AL
Test Command
OK
EN
TI
ERROR
Read Command
Responses
AT+CGDSCONT?
+CGDSCONT: [<cid>,<p_cid>,<d_comp>,<h_comp>
N
OK
FI
[...]]]
D
[<CR><LF>+CGDSCONT: <cid>,<p_cid>,<d_comp>,<h_comp>
Write Command
C
O
ERROR
OK
ERROR
O
M
AT
+CGDSCONT=<cid>[,<p_ci
d>[,<d_comp>[,<h_comp>]]
]
Responses
C
Defined values
SI
M
<cid>
a numeric parameter which specifies a particular PDP context definition. The parameter is local to
the TE-MT interface and is used in other PDP context-related commands. The range of permitted
values (minimum value = 1) is returned by the test form of the command.
NOTE: The <cid>s for network-initiated PDP contexts will have values outside the ranges
indicated for the <cid> in the test form of the commands +CGDCONT and +CGDSCONT.
<p_cid>
a numeric parameter which specifies a particular PDP context definition which has been specified
SIM7500_SIM7600 Series_AT Command Manual_V1.07
199
2017-12-25
Smart Machine Smart Decision
TI
AL
FI
L
E
by use of the +CGDCONT command. The parameter is local to the TE-MT interface. The list of
permitted values is returned by the test form of the command.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<d_comp>
a numeric parameter that controls PDP data compression (applicable for SNDCPonly) (refer
3GPP TS 44.065 [61])
0
off
1
on (manufacturer preferred compression)
2
V.42bis
Other values are reserved.
C
O
N
FI
D
EN
<h_comp>
a numeric parameter that controls PDP header compression (refer 3GPP TS 44.065 [61] and
3GPP TS 25.323 [62])
0
off
1
on (manufacturer preferred compression)
2
RFC1144 (applicable for SNDCP only)
3
RFC2507
4
RFC3095 (applicable for PDCP only)
Other values are reserved.
Examples
M
AT+CGDSCONT?
+CGDSCONT: 2,1,0,0
SI
M
C
O
OK
AT+CGDSCONT=2,1
OK
AT+CGDSCONT=?
+CGDSCONT: (1-24,100-179),(4,5,6),"IP",(0-2),(0-4)
+CGDSCONT: (1-24,100-179),(4,5,6),"PPP",(0-2),(0-4)
+CGDSCONT: (1-24,100-179),(4,5,6),"IPV6",(0-2),(0-4)
+CGDSCONT: (1-24,100-179),(4,5,6),"IPV4V6",(0-2),(0-4)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
200
2017-12-25
Smart Machine Smart Decision
9.6
AT+CGTFT Traffic Flow Template
Description
YES
References
AL
SIM PIN
FI
L
E
This command allows the TE to specify a Packet Filter - PF for a Traffic Flow Template - TFT that
is used in the GGSN in UMTS/GPRS and Packet GW in EPS for routing of packets onto different
QoS flows towards the TE. The concept is further described in the 3GPP TS 23.060 [47]. A TFT
consists of from one and up to 16 Packet Filters, each identified by a unique <packet filter
identifier>. A Packet Filter also has an <evaluation precedence index> that is unique within all TFTs
associated with all PDP contexts that are associated with the same PDP address.
3GPP TS 27.007
TI
Syntax
Responses
+CGTFT: <PDP_type>,(list
of
supported
<packet
filter
identifier>s),(list
of
supported
<evaluation
precedence
index>s),(list of supported <source address and subnet
mask>s),(list of supported <protocol number (ipv4) / next header
(ipv6)>s),(list of supported <destination port range>s),(list of
supported <source port range>s),(list of supported <ipsec security
parameter index (spi)>s),(list of supported <type of service (tos)
(ipv4) and mask / traffic class (ipv6) and mask>s),(list of supported
<flow label (ipv6)>s)
[<CR><LF>+CGTFT: <PDP_type>,(list of supported <packet filter
identifier>s),(list
of
supported
<evaluation
precedence
index>s),(list of supported <source address and subnet
mask>s),(list of supported <protocol number (ipv4) / next header
(ipv6)>s),(list of supported <destination port range>s),(list of
supported <source port range>s),(list of supported <ipsec security
parameter index (spi)>s),(list of supported <type of service (tos)
(ipv4) and mask / traffic class (ipv6) and mask>s),(list of supported
<flow label (ipv6)>s)
[...]]
SI
M
C
O
M
C
O
N
FI
D
EN
Test Command
AT+CGTFT=?
OK
ERROR
Read Command
Responses
AT+CGTFT?
+CGTFT: [<cid>,<packet filter identifier>,<evaluation precedence
index>,<source address and subnet mask>,<protocol number (ipv4)
/ next header (ipv6)>,<destination port range>,<source port
SIM7500_SIM7600 Series_AT Command Manual_V1.07
201
2017-12-25
Smart Machine Smart Decision
AL
FI
L
E
range>,<ipsec security parameter index (spi)>,<type of service (tos)
(ipv4) and mask / traffic class (ipv6) and mask>,<flow label
(ipv6)>
[<CR><LF>+CGTFT: <cid>,<packet filter identifier>,<evaluation
precedence index>,<source address and subnet mask>,<protocol
number (ipv4) / next header (ipv6)>,<destination port
range>,<source port range>,<ipsec security parameter index
(spi)>,<type of service (tos) (ipv4) and mask / traffic class (ipv6)
and mask>,<flow label (ipv6)>
[...]]]
OK
Responses
AT+CGTFT=<cid>[,[<packe
t
filter
identifier>,<evaluation
precedence index>[,<source
address
and
subnet
mask>[,<protocol
number
(ipv4)
/
next
header
(ipv6)>[,<destination
port
range>[,<source
port
range>[,<ipsec
security
parameter
index
(spi)>[,<type of service (tos)
(ipv4) and mask / traffic
class
(ipv6)
and
mask>[,<flow
label
(ipv6)>]]]]]]]]]
OK
EN
Write Command
TI
ERROR
O
M
C
O
N
FI
D
ERROR
Responses
AT+CGTFT
OK
M
C
Execute Command
ERROR
SI
Defined values
<cid>
a numeric parameter which specifies a particular PDP context definition (see theAT+CGDCONT
and AT+CGDSCONT commands).
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
SIM7500_SIM7600 Series_AT Command Manual_V1.07
202
2017-12-25
Smart Machine Smart Decision
O
N
FI
D
EN
TI
AL
FI
L
E
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<packet filter identifier>
a numeric parameter, value range from 1 to 16.
<evaluation precedence index>
a numeric parameter. The value range is from 0 to 255.
<source address and subnet mask>
string type The string is given as dot-separated numeric (0-255) parameters on the form:
"a1.a2.a3.a4.m1.m2.m3.m4" for IPv4 or
"a1.a2.a3.a4.a5.a6.a7.a8.a9.a10.a11.a12.a13.a14.a15.a16.m1.m2.m3.m4.m5.m6.m7.m8.m9.m10.m1
1.m12.m13.m14.m15.m16", for IPv6.
<protocol number (ipv4) / next header (ipv6)>
a numeric parameter, value range from 0 to 255.
<destination port range>
string type. The string is given as dot-separated numeric (0-65535) parameters on the form "f.t".
<source port range>
string type. The string is given as dot-separated numeric (0-65535) parameters on the form "f.t".
<ipsec security parameter index (spi)>
numeric value in hexadecimal format. The value range is from 00000000 to FFFFFFFF.
<type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask>
string type. The string is given as dot-separated numeric (0-255) parameters on the form "t.m".
<flow label (ipv6)>
numeric value in hexadecimal format. The value range is from 00000 to FFFFF. Valid for IPv6 only.
C
Examples
M
AT+CGTFT?
+CGTFT: 2,1,0,"74.125.71.99.255.255.255.255",0,0.0,0.0,0,0.0,0
SI
M
C
O
OK
AT+CGTFT=2,1,0,"74.125.71.99.255.255.255.255"
OK
AT+CGTFT=?
+CGTFT: "IP",(1-2),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFF
FFF),(0-255.0-255),(0-FFFFF)
+CGTFT: "PPP",(1-2),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFF
FFFF),(0-255.0-255),(0-FFFFF)
+CGTFT: "IPV6",(1-2),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFF
FFFFF),(0-255.0-255),(0-FFFFF)
+CGTFT:"IPV4V6",(1-16),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFFFFF)
,(0-255.0-255),(0-FFFFF)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
203
2017-12-25
Smart Machine Smart Decision
OK
9.7
AT+CGQREQ Quality of service profile (requested)
Description
SIM PIN
References
3GPP TS 27.007
AL
YES
FI
L
E
This command allows the TE to specify a Quality of Service Profile that is used when the MT sends
an Activate PDP Context Request message to the network.. A special form of the set command
(AT+CGQREQ=<cid>) causes the requested profile for context number <cid> to become
undefined.
TI
Syntax
Responses
+CGQREQ: <PDP_type>, (list of supported <precedence>s), (list
of supported <delay>s), (list of supported <reliability>s) , (list of
supported <peak>s), (list of supported <mean>s) [<CR><LF>
+CGQREQ: <PDP_type>, (list of supported <precedence>s), (list
of supported <delay>s), (list of supported <reliability>s) , (list of
supported <peak>s), (list of supported <mean>s)
[…]]
OK
O
N
FI
D
EN
Test Command
AT+CGQREQ=?
ERROR
C
O
M
AT+CGQREQ?
Write Command
M
Responses
C
Read Command
+CGQREQ: [<cid>, <precedence >, <delay>, <reliability>,
<peak>, <mean>[<CR><LF>
+CGQREQ: <cid>, <precedence >, <delay>, <reliability.>, <peak>,
<mean>[…]]]
OK
ERROR
Responses
OK
Execution Command
Responses
AT+CGQREQ
OK
SI
AT+CGQREQ=<cid>[,<prec
edence>[,<delay>[,<reliabilit
y>[,<peak>[,<mean>]]]]]
ERROR
ERROR
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
204
2017-12-25
Smart Machine Smart Decision
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command). The range is from 1 to 24,100 to 179
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<precedence>
A numeric parameter which specifies the precedence class:
0 – network subscribed value
1 – high priority
2 – normal priority
3 – low priority
<delay>
A numeric parameter which specifies the delay class:
0 – network subscribed value
1 – delay class 1
2 – delay class 2
3 – delay class 3
4 – delay class 4
<reliability>
A numeric parameter which specifies the reliability class:
0 – network subscribed value
1 – Non real-time traffic,error-sensitive application that cannot cope with data loss
2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss
3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/SM,and SMS
4 – Real-time traffic,error-sensitive application that can cope with data loss
5 – Real-time traffic error non-sensitive application that can cope with data loss
<peak>
A numeric parameter which specifies the peak throughput class:
0 – network subscribed value
1 – Up to 1000 (8 kbit/s)
2 – Up to 2000 (16 kbit/s)
3 – Up to 4000 (32 kbit/s)
4 – Up to 8000 (64 kbit/s)
5 – Up to 16000 (128 kbit/s)
6 – Up to 32000 (256 kbit/s)
7 – Up to 64000 (512 kbit/s)
8 – Up to 128000 (1024 kbit/s)
9 – Up to 256000 (2048 kbit/s)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
205
2017-12-25
FI
L
AL
N
FI
D
EN
TI
<mean>
A numeric parameter which specifies the mean throughput class:
0
– network subscribed value
1
– 100 (~0.22 bit/s)
2
– 200 (~0.44 bit/s)
3
– 500 (~1.11 bit/s)
4
– 1000 (~2.2 bit/s)
5
– 2000 (~4.4 bit/s)
6
– 5000 (~11.1 bit/s)
7
– 10000 (~22 bit/s)
8
– 20000 (~44 bit/s)
9
– 50000 (~111 bit/s)
10 – 100000 (~0.22 kbit/s)
11 – 200000 (~0.44 kbit/s)
12 – 500000 (~1.11 kbit/s)
13 – 1000000 (~2.2 kbit/s)
14 – 2000000 (~4.4 kbit/s)
15 – 5000000 (~11.1 kbit/s)
16 – 10000000 (~22 kbit/s)
17 – 20000000 (~44 kbit/s)
18 – 50000000 (~111 kbit/s)
31 – optimization
E
Smart Machine Smart Decision
O
Examples
C
O
M
C
AT+CGQREQ?
+CGQREQ:
OK
AT+CGQREQ=?
+CGQREQ: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQREQ: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQREQ: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQREQ: "IPV4V6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
M
OK
AT+CGEQREQ 3G quality of service profile (requested)
SI
9.8
Description
The test command returns values supported as a compound value.
The read command returns the current settings for each defined context for which a QOS was
explicitly specified.
The write command allows the TE to specify a Quality of Service Profile for the context identified
SIM7500_SIM7600 Series_AT Command Manual_V1.07
206
2017-12-25
Smart Machine Smart Decision
by the context identification parameter <cid> which is used when the MT sends an Activate PDP
Context Request message to the network.
A special form of the write command, AT+CGEQREQ=<cid> causes the requested profile for
context number <cid> to become undefined.
SIM PIN
E
3GPP TS 27.007
FI
L
YES
References
Syntax
Responses
+CGEQREQ: <PDP_type>,(list of supported <Traffic class>s),(list
of supported <Maximum bitrate UL>s),(list of supported
<Maximum bitrate DL>s),(list of supported <Guaranteed bitrate
UL>s,(list of supported <Guaranteed bitrate DL>s),(list of
supported <Deliv ery order>s),(list of supported <Maximum SDU
size>s),(list of supported <SDU error ratio>s),(list of supported
<Residual bit error Ratio>s),(list of supported <Delivery of
erroneous SDUs>s),(list of Supported <Transfer delay>s),(list of
supported <Traffic handling priority>s),(list of supported <Source
statistics descriptor>s),(list of supported <Signaling indication
flag>s)
OK
N
FI
D
EN
TI
AL
Test Command
AT+CGEQREQ=?
ERROR
SI
M
C
O
+CGEQREQ: [<cid>,<Traffic class>,<Maximum bitrate UL>,
<Maximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed
bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error
ratio>,<Residual bit error ratio>,<Delivery of erroneous SDUs>,
<Transfer Delay>,<Traffic handling priority>,<Source statistics
descriptor>,< Signaling indication flag>][<CR><LF>+CGEQREQ:
<cid>,<Traffic class>,<Maximum bitrate UL>,<Maximum bitrate
DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery
order>,<Maximum SDU size>,<SDU error ratio>,<Residual bit
error ratio>,<Delivery of erroneous SDUs>,<Transfer Delay>,
<Traffic handling priority>,<Source statistics descriptor>,
<Signaling indication flag> […]]
OK
C
M
AT+CGEQREQ?
Responses
O
Read Command
ERROR
Write Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
207
2017-12-25
Smart Machine Smart Decision
AT+CGEQREQ=<cid>[,<Tr
affic class>[,<Maximum bit
rate UL>[,<Maximum bitrat
e DL>[,<Guaranteed bitrate
UL>[,<Guaranteed bitrate
DL>[,<Delivery order>[,<M
aximum SDU size>[,<SDU
error ratio>[,<Residual bit
error ratio>[,<Delivery of
erroneous SDUs>[,<Transfe
r delay>[,<Traffic handling
priority>[,<Source statistic
s descriptor>[,<Signaling in
dication flag>]]]]]]]]]]]]]]
OK
Execution Command
Responses
AT+CGEQREQ
OK
FI
L
E
ERROR
EN
TI
AL
+CME ERROR: <err>
D
ERROR
FI
Defined values
SI
M
C
O
M
C
O
N
<cid>
Parameter specifies a particular PDP context definition.The parameter is also used in other PDP
context-related commands. The range is from 1 to 24,100 to 179
<Traffic class>
0 – conversational
1 – streaming
2 – interactive
3 – background
4 – subscribed value
<Maximum bitrate UL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a
SAP. As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQREQ=…,32,…).
The range is from 0 to 11520. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Maximum bitrate DL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQREQ=…,32,…).
The range is from 0 to 42200. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Guaranteed bitrate UL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
SIM7500_SIM7600 Series_AT Command Manual_V1.07
208
2017-12-25
Smart Machine Smart Decision
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
32(e.g.AT+CGEQREQ=…,32,…).
The range is from 0 to 11520. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Guaranteed bitrate DL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.AT+CGEQREQ=…,32,…).
The range is from 0 to 42200. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Delivery order>
This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.
0
– no
1
– yes
2
– subscribed value
<Maximum SDU size>
This parameter indicates the maximum allowed SDU size in octets.
The range is from 0 to 1520. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<SDU error ratio>
This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU
error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10-3
would be specified as “5E3”(e.g.AT+CGEQREQ=..,”5E3”,…).
“0E0” – subscribed value
“1E2”
“7E3”
“1E3”
“1E4”
“1E5”
“1E6”
“1E1”
<Residual bit error ratio>
This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If
no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered
SDUs.As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”(e.g.
AT+CGEQREQ=…,”5E3”,..).
“0E0” – subscribed value
“5E2”
“1E2”
“5E3”
“4E3”
“1E3”
“1E4”
“1E5”
SIM7500_SIM7600 Series_AT Command Manual_V1.07
209
2017-12-25
Smart Machine Smart Decision
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
“1E6”
“6E8”
<Delivery of erroneous SDUs>
This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
0 – no
1 – yes
2 – no detect
3 – subscribed value
<Transfer delay>
This parameter indicates the targeted time between request to transfer an SDU at one SAP to its
delivery at the other SAP,in milliseconds.
The range is 0 and from 100 to 4000. The default value is 0. If the parameter is set to '0' the
subscribed value will be requested.
<Traffic handling priority>
This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS
Bearer compared to the SDUs of the other bearers.
The range is from 0 to 3. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<Source statistics descriptor>
This parameter indicates profile parameter that Source statistics descriptor for requested UMTS
QoS
The range is from 0 to 1. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<Signaling indication flag>
This parameter indicates Signaling flag.
The range is from 0 to 1 The default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
Examples
SI
AT+CGEQREQ?
+CGEQREQ:
OK
AT+CGEQREQ=?
+CGEQREQ: "IP",(0-4),(0-11520),(0-42200),(0-11520),(0-42200),(0-2),(0-1520),("0E0","1E
1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E
4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
210
2017-12-25
Smart Machine Smart Decision
FI
L
E
+CGEQREQ: "PPP",(0-4),(0-11520),(0-42200),(0-11520),(0-42200),(0-2),(0-1520),("0E0","1
E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1
E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
+CGEQREQ: "IPV6",(0-4),(0-11520),(0-42200),(0-11520),(0-42200),(0-2),(0-1520),("0E0","
1E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","
1E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
+CGEQREQ:"IPV4V6",(0-4),(0-11520),(0-42200),(0-11520),(0-42200),(0-2),(0-1520),("0E0","1E1
","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4","1E5","1
E6","6E8"),(0-3),(0,100-4000),(0-3),(0-1),(0-1)
AT+CGQMIN Quality of service profile (minimum acceptable)
TI
9.9
AL
OK
EN
Description
3GPP TS 27.007
N
YES
References
M
C
O
Read Command
AT+CGQMIN?
Responses
+CGQMIN: <PDP_type>, (list of supported <precedence>s), (list
of supported <delay>s), (list of supported <reliability>s) , (list of
supported <peak>s), (list of supported <mean>s) [<CR><LF>
+CGQMIN: <PDP_type>, (list of supported <precedence>s), (list
of supported <delay>s), (list of supported <reliability>s) , (list of
supported <peak>s), (list of supported <mean>s)[…]]
OK
C
M
Test Command
AT+CGQMIN=?
O
Syntax
SI
FI
SIM PIN
D
This command allows the TE to specify a minimum acceptable profile which is checked by the MT
against the negotiated profile returned in the Activate PDP Context Accept message.A special form
of the set command,AT+CGQMIN=<cid> causes the minimum acceptable profile for context
number <cid> to become undefined.
ERROR
Responses
+CGQMIN: [<cid>, <precedence >, <delay>, <reliability>,
<peak>, <mean>[<CR><LF>
+CGQMIN: <cid>, <precedence >, <delay>, <reliability.>, <peak>,
<mean>
[…]]]
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
211
2017-12-25
Smart Machine Smart Decision
Write Command
AT+CGQMIN=<cid>[,<prec
edence>[,<delay>[,<reliabilit
y>[,<peak> [,<mean>]]]]]
Responses
OK
Execution Command
AT+CGQMIN
Responses
OK
E
ERROR
FI
L
ERROR
Defined values
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command). The range is from 1 to 24,100 to 179.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<precedence>
A numeric parameter which specifies the precedence class:
0 – network subscribed value
1 – high priority
2 – normal priority
3 – low priority
<delay>
A numeric parameter which specifies the delay class:
0 – network subscribed value
1 – delay class 1
2 – delay class 2
3 – delay class 3
4 – delay class 4
<reliability>
A numeric parameter which specifies the reliability class:
0 – network subscribed value
1 – Non real-time traffic,error-sensitive application that cannot cope with data loss
2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss
3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/SM,and SMS
4 – Real-time traffic,error-sensitive application that can cope with data loss
5 – Real-time traffic error non-sensitive application that can cope with data loss
<peak>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
212
2017-12-25
FI
L
AL
M
C
O
M
C
O
N
FI
D
EN
TI
A numeric parameter which specifies the peak throughput class:
0 – network subscribed value
1 – Up to 1000 (8 kbit/s)
2 – Up to 2000 (16 kbit/s)
3 – Up to 4000 (32 kbit/s)
4 – Up to 8000 (64 kbit/s)
5 – Up to 16000 (128 kbit/s)
6 – Up to 32000 (256 kbit/s)
7 – Up to 64000 (512 kbit/s)
8 – Up to 128000 (1024 kbit/s)
9 – Up to 256000 (2048 kbit/s)
<mean>
A numeric parameter which specifies the mean throughput class:
0
– network subscribed value
1
– 100 (~0.22 bit/s)
2
– 200 (~0.44 bit/s)
3
– 500 (~1.11 bit/s)
4
– 1000 (~2.2 bit/s)
5
– 2000 (~4.4 bit/s)
6
– 5000 (~11.1 bit/s)
7
– 10000 (~22 bit/s)
8
– 20000 (~44 bit/s)
9
– 50000 (~111 bit/s)
10 – 100000 (~0.22 kbit/s)
11 – 200000 (~0.44 kbit/s)
12 – 500000 (~1.11 kbit/s)
13 – 1000000 (~2.2 kbit/s)
14 – 2000000 (~4.4 kbit/s)
15 – 5000000 (~11.1 kbit/s)
16 – 10000000 (~22 kbit/s)
17 – 20000000 (~44 kbit/s)
18 – 50000000 (~111 kbit/s)
31 – optimization
E
Smart Machine Smart Decision
Examples
SI
AT+CGQMIN?
+CGQMIN:
OK
AT+CGQMIN=?
+CGQMIN: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQMIN: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQMIN: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
213
2017-12-25
Smart Machine Smart Decision
+CGQMIN: "IPV4V6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
OK
AT+CGEQMIN 3G quality of service profile (minimum acceptable)
E
9.10
FI
L
Description
SIM PIN
References
3GPP TS 27.007
D
YES
EN
TI
AL
The test command returns values supported as a compound value.
The read command returns the current settings for each defined context for which a QOS was
explicitly specified.
The write command allow the TE to specify a Quallity of Service Profile for the context identified
by the context identification parameter <cid> which is checked by the MT against the negotiated
profile returned in the Activate/Modify PDP Context Accept message.
A special form of the write command, AT+CGEQMIN=<cid> causes the requested for context
number <cid> to become undefined.
FI
Syntax
Responses
AT+CGEQMIN=?
+CGEQMIN: <PDP_type>,(list of supported <Traffic class>s),(list
of supported <Maximum bitrate UL>s),(list of supported
<Maximum bitrate DL>s),(list of supported <Guaranteed bitrate
UL>s,(list of supported <Guaranteed bitrate DL>s),(list of
supported <Deliv ery order>s),(list of supported <Maximum SDU
size>s),(list of supported <SDU error ratio>s),(list of supported
<Residual bit error Ratio>s),(list of supported <Delivery of
erroneous SDUs>s),(list of Supported <Transfer delay>s),(list of
supported <Traffic handling priority>s),(list of supported <Source
statistics descriptor>s),(list of supported <Signaling indication
flag>s)
OK
M
C
O
M
C
O
N
Test Command
ERROR
Responses
AT+CGEQMIN?
+CGEQMIN: [<cid>,<Traffic class>,<Maximum bitrate UL>,
<Maximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed
bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error
ratio>,<Residual bit error ratio>,<Delivery of erroneous SDUs>,
<Transfer Delay>,<Traffic handling priority>,<Source statistics
descriptor>,< Signaling indication flag>][<CR><LF>+CGEQMIN:
SI
Read Command
SIM7500_SIM7600 Series_AT Command Manual_V1.07
214
2017-12-25
Smart Machine Smart Decision
E
<cid>,<Traffic class>,<Maximum bitrate UL>,<Maximum bitrate
DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery
order>,<Maximum SDU size>,<SDU error ratio>,<Residual bit
error ratio>,<Delivery of erroneous SDUs>,<Transfer Delay>,
<Traffic handling priority>,<Source statistics descriptor>,
<Signaling indication flag>[…]]
OK
Responses
AT+CGEQMIN=<cid>[,<Tr
affic class>[,<Maximum bit
rate UL>[,<Maximum bitrat
e DL>[,<Guaranteed bitrate
UL>[,<Guaranteed bitrate
DL>[,<Delivery order>[,<M
aximum SDU size>[,<SDU
error ratio>[,<Residual bit
error ratio>[,<Delivery of
erroneous SDUs>[,<Transfe
r delay>[,<Traffic handling
priority>[,<Source statistic
s descriptor>[,<Signaling in
dication flag>]]]]]]]]]]]]]]
OK
TI
EN
ERROR
O
N
FI
D
+CME ERROR: <err>
Responses
OK
C
Execution Command
AT+CGEQMIN
AL
Write Command
FI
L
ERROR
ERROR
M
Defined values
SI
M
C
O
<cid>
Parameter specifies a particular PDP context definition.The parameter is also used in other PDP
context-related commands. The range is from 1 to 24,100 to 179.
<Traffic class>
0 – conversational
1 – streaming
2 – interactive
3 – background
4 – subscribed value
<Maximum bitrate UL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQMIN=…,32,…).
The range is from 0 to 11520. The default value is 0. If the parameter is set to '0' the subscribed
SIM7500_SIM7600 Series_AT Command Manual_V1.07
215
2017-12-25
Smart Machine Smart Decision
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
value will be requested.
<Maximum bitrate DL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQMIN=…,32,…).
The range is from 0 to 42200. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Guaranteed bitrate UL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.AT+CGEQMIN=…,32,…).
The range is from 0 to 11520. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Guaranteed bitrate DL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.AT+CGEQMIN=…,32,…).
The range is from 0 to 42200. The default value is 0. If the parameter is set to '0' the subscribed
value will be requested.
<Delivery order>
This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.
0 – no
1 – yes
2 – subscribed value
<Maximum SDU size>
This parameter indicates the maximum allowed SDU size inoctets.
The range is from 0 to 1520. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<SDU error ratio>
This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU
error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10-3
would be specified as “5E3”(e.g.AT+CGEQMIN=..,”5E3”,…).
“0E0” – subscribed value
“1E2”
“7E3”
“1E3”
“1E4”
“1E5”
“1E6”
“1E1”
<Residual bit error ratio>
This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If
no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered
SDUs.As an example a target residual bit error ratio of 5*10-3 would be specified as “5E3”(e.g.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
216
2017-12-25
Smart Machine Smart Decision
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
AT+CGEQMIN=…,”5E3”,..).
“0E0” – subscribed value
“5E2”
“1E2”
“5E3”
“4E3”
“1E3”
“1E4”
“1E5”
“1E6”
“6E8”
<Delivery of erroneous SDUs>
This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
0 – no
1 – yes
2 – no detect
3 – subscribed value
<Transfer delay>
This parameter indicates the targeted time between request to transfer an SDU at one SAP to its
delivery at the other SAP,in milliseconds.
The range is 0 and from 100 to 4000. The default value is 0. If the parameter is set to '0' the
subscribed value will be requested.
<Traffic handling priority>
This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS
Bearer compared to the SDUs of the other bearers.
The range is from 0 to 3. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<Source statistics descriptor>
This parameter indicates profile parameter that Source statistics descriptor for requested UMTS
QoS
The range is from 0 to 1. The default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<Signaling indication flag>
This parameter indicates Signaling flag.
The range is from 0 to 1 The default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP
Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
SIM7500_SIM7600 Series_AT Command Manual_V1.07
217
2017-12-25
Smart Machine Smart Decision
Examples
EN
TI
AL
FI
L
E
AT+CGEQMIN?
+CGEQMIN:
OK
AT+CGEQMIN=?
+CGEQMIN: "IP",(0-4),(0-11520),(0-42200),(0-115200),(0-42200),(0-2),(0-1520),("0E0","1E
1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E
4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
+CGEQMIN: "PPP",(0-4),(0-11520),(0-42200),(0-115200),(0-42200),(0-2),(0-1520),("0E0","1
E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1
E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
+CGEQMIN: "IPV6",(0-4),(0-11520),(0-42200),(0-115200),(0-42200),(0-2),(0-1520),("0E0","
1E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","
1E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3) ,(0-1),(0-1)
+CGEQMIN:"IPV4V6",(0-4),(0-11520),(0-42200),(0-115200),(0-42200),(0-2),(0-1520),("0E0","1E
1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4","1E5","
1E6","6E8"),(0-3),(0,100-4000),(0-3),(0-1),(0-1)
FI
AT+CGDATA Enter data state
N
9.11
D
OK
O
Description
C
The command causes the MT to perform whatever actions are necessary to establish
communication between the TE and the network using one or more Packet Domain PDP types. This
may include performing a PS attach and one or more PDP context activations. The command is not
used in CDMA/EVDO mode.
3GPP TS 27.007
O
YES
References
M
SIM PIN
C
Syntax
SI
M
Test Command
AT+CGDATA=?
Write Command
AT+CGDATA=[<L2P>,[<ci
d>]]
Responses
+CGDATA: (list of supported <L2P>s)
OK
ERROR
Responses
CONNECT [<text>]
NO CARRIER
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
218
2017-12-25
Smart Machine Smart Decision
ERROR
+CME ERROR: <err>
Defined values
TI
AL
FI
L
E
<L2P>
A string parameter that indicates the layer 2 protocol to be used between the TE and MT.
PPP
Point-to-point protocol for a PDP such as IP
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command).
1…24,100…179
EN
Examples
FI
Show PDP address
C
Description
N
AT+CGPADDR
O
9.12
D
AT+CGDATA=?
+CGDATA: ("PPP")
OK
AT+CGDATA="PPP",1
CONNECT 115200
The write command returns a list of PDP addresses for the specified context identifiers.
3GPP TS 27.007
O
YES
References
M
SIM PIN
C
Syntax
SI
M
Test Command
AT+CGPADDR=?
Responses
[+CGPADDR: (list of defined <cid>s)]
OK
ERROR
Write Command
Responses
AT+CGPADDR=
<cid>[,<cid>[,…]]
[+CGPADDR:<cid>,<PDP_addr>[<CR><LF>
+CGPADDR: <cid>,<PDP_addr>[...]]]
OK
SIM card supports IPV4V6 type and the PDP_type of the command
SIM7500_SIM7600 Series_AT Command Manual_V1.07
219
2017-12-25
Smart Machine Smart Decision
“at+cgdcont” defined is ipv4v6 :
[+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6>]
+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6> [...]]]
OK
ERROR
Execution Command
Responses
AT+CGPADDR
[+CGPADDR: <cid>,<PDP_addr>]
+CGPADDR: <cid>,<PDP_addr>[...]]]
OK
FI
L
E
+CME ERROR: <err>
EN
TI
AL
SIM card supports IPV4V6 type and the PDP_type of the command
“at+cgdcont” defined is ipv4v6 :
[+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6>]
+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6> [...]]]
OK
ERROR
D
+CME ERROR: <err>
FI
Defined values
SI
M
C
O
M
C
O
N
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command). If no <cid> is specified, the addresses for all defined contexts are returned.
1…24,100…179
<PDP_addr>
A string that identifies the MT in the address space applicable to the PDP. The address may be static
or dynamic. For a static address, it will be the one set by the AT+CGDCONT command when the
context was defined. For a dynamic address it will be the one assigned during the last PDP context
activation that used the context definition referred to by <cid>. <PDP_addr> is omitted if none is
available.
<PDP_addr_IPV4>
A string parameter that identifies the MT in the address space applicable to the PDP.
<PDP_addr_IPV6>
A string parameter that identifies the MT in the address space applicable to the PDP when the
sim_card supports ipv6. The pdp type must be set to “ipv6” or “ipv4v6” by the AT+CGDCONT
command.
Examples
AT+CGPADDR =?
+CGPADDR: (1)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
220
2017-12-25
Smart Machine Smart Decision
FI
L
OK
AT+CGPADDR
+CGPADDR: 1,10.195.1.140,36.9.136.148.128.48.134.218.173.205.47.44.88.174.123.200
+CGPADDR: 2,10.195.34.92,36.9.136.148.128.48.146.115.92.140.135.230.248.131.5.90
+CGPADDR: 3,0.0.0.0,0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0
AT+CGCLASS
GPRS mobile station class
TI
Description
AL
OK
9.13
E
AT+CGPADDR=1
+CGDCONT: 1,"IPV4V6","","0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0",0,0,0,0
SIM PIN
References
3GPP TS 27.007
D
YES
EN
This command is used to set the MT to operate according to the specified GPRS mobile class.
FI
Syntax
Responses
+CGCLASS: (list of supported <class>s)
N
Test Command
AT+CGCLASS=?
O
OK
M
Read Command
AT+CGCLASS?
C
ERROR
M
C
O
Write Command
AT+CGCLASS=<class>
SI
Execution Command
AT+CGCLASS
Responses
+CGCLASS: <class>
OK
ERROR
Responses
OK
ERROR
+CME ERROR: <err>
Responses
Set default value:
OK
ERROR
Defined values
<class>
A string parameter which indicates the GPRS mobile class (in descending order of functionality)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
221
2017-12-25
Smart Machine Smart Decision
A –
class A (highest)
Examples
FI
L
AT+CGEREP GPRS event reporting
TI
Description
AL
9.14
E
AT+CGCLASS=?
+CGCLASS: ("A")
OK
AT+CGCLASS?
+CGCLASS: "A"
OK
3GPP TS 27.007
Syntax
O
M
Test Command
AT+CGEREP=?
C
O
YES
References
N
SIM PIN
FI
D
EN
The write command enables or disables sending of unsolicited result codes, “+CGEV” from MT to
TE in the case of certain events occurring in the Packet Domain MT or the network. <mode>
controls the processing of unsolicited result codes specified within this command. <bfr> controls
the effect on buffered codes when <mode> 1 or 2 is entered. If a setting is not supported by the MT,
ERROR or +CME ERROR: is returned.
Read command returns the current <mode> and buffer settings.
Test command returns the modes and buffer settings supported by the MT as compound values.
M
C
Read Command
AT+CGEREP?
SI
Write Command
AT+CGEREP=
<mode>[,<bfr>]
Execution Command
AT+CGEREP
Responses
+CGEREP: (list of supported <mode>s),(list of supported <bfr>s)
OK
ERROR
Responses
+CGEREP: <mode>,<bfr>
OK
ERROR
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
222
2017-12-25
Smart Machine Smart Decision
Defined values
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
<mode>
0 – buffer unsolicited result codes in the MT; if MT result code buffer is full, the oldest
ones can be discarded. No codes are forwarded to the TE.
1 – discard unsolicited result codes when MT-TE link is reserved (e.g. in on-line data
mode); otherwise forward them directly to the TE.
2 – buffer unsolicited result codes in the MT when MT-TE link is reserved (e.g. in on-line
data mode) and flush them to the TE when MT-TE link becomes available; otherwise
forward them directly to the TE.
<bfr>
0 – MT buffer of unsolicited result codes defined within this command is cleared when
<mode> 1 or 2 is entered.
1 – MT buffer of unsolicited result codes defined within this command is flushed to the TE
when <mode> 1 or 2 is entered (OK response shall be given before flushing the codes).
The following unsolicited result codes and the corresponding events are defined:
+CGEV: REJECT <PDP_type>, <PDP_addr>
A network request for PDP context activation occurred when the MT was unable to
report it to the TE with a +CRING unsolicited result code and was automatically
rejected.
+CGEV: NW REACT <PDP_type>, <PDP_addr>, [<cid>]
The network has requested a context reactivation. The <cid> that was used to reactivate
the context is provided if known to the MT.
+CGEV: NW DEACT <PDP_type>, <PDP_addr>, [<cid>]
The network has forced a context deactivation. The <cid> that was used to activate the
context is provided if known to the MT.
+CGEV: ME DEACT <PDP_type>, <PDP_addr>, [<cid>]
The mobile equipment has forced a context deactivation. The <cid> that was used to
activate the context is provided if known to the MT.
+CGEV: NW DETACH
The network has forced a Packet Domain detach. This implies that all active contexts
have been deactivated. These are not reported separately.
+CGEV: ME DETACH
The mobile equipment has forced a Packet Domain detach. This implies that all active
contexts have been deactivated. These are not reported separately.
+CGEV: NW CLASS <class>
The network has forced a change of MS class. The highest available class is reported
(see AT+CGCLASS).
+CGEV: ME CLASS <class>
The mobile equipment has forced a change of MS class. The highest available class is
reported (see AT+CGCLASS).
Examples
SIM7500_SIM7600 Series_AT Command Manual_V1.07
223
2017-12-25
Smart Machine Smart Decision
AT+CGAUTH Set type of authentication for PDP-IP connections of
FI
L
9.15
E
AT+CGEREP=?
+CGEREP: (0-2),(0-1)
OK
AT+CGEREP?
+CGEREP: 0,0
OK
AL
GPRS
Description
SIM PIN
References
Vendor
EN
YES
TI
This command is used to set type of authentication for PDP-IP connections of GPRS.
D
Syntax
Responses
AT+CGAUTH=?
+CGAUTH:, ,127 ,127(for CDMA1x-EvDo only)
+CGAUTH:(range of supported <cid>s),(list of supported <auth_type> s),127,127
N
FI
Test Command
C
O
(NOTE: the first line of the response is for CDMA 1x and Evdo
only)
OK
M
ERROR
SI
M
C
O
Read Command
AT+CGAUTH?
Write Command
AT+CGAUTH=<cid>[,<aut
h_type>[,<passwd>[,<user>]
]]
+CME ERROR: <err>
Responses
+CGAUTH: ,,"user ","passwd"(for CDMA1x-EvDo only)
+CGAUTH:[ <cid>,<auth_type>[,<user>,<passwd>]]<CR><LF>
…
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
AT+CGAUTH=,,<user>,<pa
SIM7500_SIM7600 Series_AT Command Manual_V1.07
224
2017-12-25
Smart Machine Smart Decision
sswd> (for
CDMA1x-EvDo)
+CME ERROR: <err>
Execution Command
AT+CGAUTH
Responses
OK
ERROR
FI
L
E
+CME ERROR: <err>
Defined values
C
O
N
FI
D
EN
TI
AL
<cid>
Parameter specifies a particular PDP context definition. This is also used in other PDP
context-related commands.
1…24,100…179
<auth_type>
Indicate the type of authentication to be used for the specified context. If CHAP is selected another
parameter <passwd> needs to be specified. If PAP is selected two additional parameters <passwd>
and <user> need to specified.
0 – none
1 – PAP
2 – CHAP
3 – PAP or CHAP
<passwd>
Parameter specifies the password used for authentication.
<user>
Parameter specifies the user name used for authentication.
Examples
O
M
AT+CGAUTH=?
+CGAUTH: ,,127,127(for CDMA1x-EvDo only)
+CGAUTH: (1-24,100-179),(0-3),127,127
SI
M
C
OK
AT+CGAUTH=1,1,”123”,”SIMCOM”
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
225
2017-12-25
Smart Machine Smart Decision
10 Hardware Related Commands
AT+CVALARM
Low and high voltage Alarm
FI
L
Description
This command is used to open or close the low voltage alarm function.
NO
References
AL
SIM PIN
E
10.1
Vendor
TI
Syntax
Responses
+CVALARM: (list of supported <enable>s), (list of supported <
<low voltage>s), (list of supported high < high voltage>s)
OK
Read Command
AT+CVALARM?
Responses
+CVALARM: <enable>,<low voltage>, <high voltage>
OK
Write Command
AT+CVALARM=<enable>[,<l
ow voltage>],[<high voltage>]
Responses
OK
O
N
FI
D
EN
Test Command
AT+CVALARM=?
C
ERROR
Defined values
SI
M
C
O
M
<enable>
0 – Close
1 – Open. If voltage < < low voltage>, it will report “UNDER-VOLTAGE WARNNING”
every 10s. If voltage > <high voltage>, it will report “OVER-VOLTAGE
WARNNING” every 10s.
<low voltage>
Between 3300mV and 4000mV. Default value is 3300.
<high voltage>
Between 4000mV and 4300mV. Default value is 4300.
NOTE:The three parameters will be saved automatically.
Examples
AT+CVALARM=1,3400,4300
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
226
2017-12-25
Smart Machine Smart Decision
FI
L
E
AT+CVALARM?
+CVALARM: 1,3400,4300
OK
AT+CVALARM=?
+CVALARM: (0,1),(3300-4000),(4000-4300)
OK
10.2
AT+CVAUXS Set state of the pin named VREG_AUX1
AL
Description
This command is used to set state of the pin which is named VREG_AUX1.
Vendor
EN
NO
References
TI
SIM PIN
Syntax
Responses
+CVAUXS: (list of supported <state>s)
OK
Read Command
AT+CVAUXS?
Responses
+CVAUXS: <state>
OK
Responses
OK
C
Write Command
AT+CVAUXS=<state>
O
N
FI
D
Test Command
AT+CVAUXS=?
M
ERROR
O
Defined values
the pin is closed.
the pin is opend(namely, open the pin)
M
C
<state>
0 –
1 –
SI
Examples
AT+CVAUXS=1
OK
AT+CVAUXS?
+CVAUXS: 1
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
227
2017-12-25
Smart Machine Smart Decision
10.3
AT+CVAUXV Set voltage value of the pin named VREG_AUX1
E
Description
SIM PIN
References
Vendor
AL
NO
FI
L
This command is used to set the voltage value of the pin which is named VREG_AUX1.
Syntax
Responses
+CVAUXV: (list of supported <voltage>s)
OK
Read Command
AT+CVAUXV?
Responses
+CVAUXV: <voltage>
OK
Write Command
AT+CVAUXV=<voltage>
Responses
OK
N
FI
D
EN
TI
Test Command
AT+CVAUXV=?
C
Defined values
O
ERROR
O
Examples
M
<voltage>
Voltage value of the pin which is named VREG_AUX1. The unit is in mV. And the value must the
multiple of 50mv.
SI
M
C
AT+CVAUXV=?
+CVAUXV: (1700-3050)
OK
AT+CVAUXV=2800
OK
AT+CVAUXV?
+CVAUXV: 2800
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
228
2017-12-25
Smart Machine Smart Decision
10.4
AT+CADC Read ADC value
Description
NO
References
FI
L
SIM PIN
E
This command is used to read the ADC value from modem. ME supports 2 types of ADC, which
are raw type and voltage type.
Vendor
Responses
+CADC: (range of supported <adc>s)
OK
Write Command
AT+CADC=<adc>
Responses
+CADC: <value>
OK
Examples
EN
N
M
C
O
<adc>
ADC type:
0 – raw type.
2 – voltage type(mv)
<value>
Integer type value of the ADC.
FI
Defined values
D
ERROR
TI
Test Command
AT+CADC=?
AL
Syntax
SI
M
C
O
AT+CADC=?
+CADC: (0,2)
OK
AT+CADC=0
+CADC: 187
OK
10.5
AT+CADC2 Read ADC2 value
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
229
2017-12-25
Smart Machine Smart Decision
This command is used to read the ADC2 value from modem. ME supports 2 types of ADC, which
are raw type and voltage type.
SIM PIN
NO
References
Vendor
Responses
+CADC2: (range of supported <adc>s)
OK
Write Command
AT+CADC2=<adc>
Responses
+CADC2: <value>
OK
TI
AL
Test Command
AT+CADC2=?
EN
ERROR
Examples
M
C
O
M
AT+CADC2=?
+CADC2: (0,2)
OK
AT+CADC2=0
+CADC2: 187
OK
C
O
N
FI
D
Defined values
<adc>
ADC2 type:
0 – raw type.
2 – voltage type(mv)
<value>
Integer type value of the ADC2.
FI
L
E
Syntax
SI
10.6
AT+CMTE
Control the module whether power shutdown when
the module’s temperature upon the critical temperature
Description
This command is used to control the module whether power shutdown when the module’s
temperature upon the critical temperature
SIM7500_SIM7600 Series_AT Command Manual_V1.07
230
2017-12-25
Smart Machine Smart Decision
SIM PIN
NO
References
Vendor
Responses
+CMTE: (list of supported<on/off>s)
OK
Read Command
AT+CMTE?
Responses
FI
L
Test Command
AT+CMTE=?
E
Syntax
+CMTE: <on/off >
Responses
OK
TI
Write Command
AT+CMTE=<on/off >
AL
OK
EN
ERROR
N
FI
<on/off>
0 – Disable temperature detection
1 – Enable temperature detection
D
Defined values
O
Examples
SI
M
C
O
M
C
AT+CMTE?
+CMTE: 1
OK
AT+CMTE=1
OK
AT+CMTE=?
+CMTE: 1
OK
NOTE:
When temperature is extreme high or low, product will power off.
URCs indicating the alert level “+CMTE:-1” or “+CMTE:1” are intended to enable the user
to take appropriate
precaution, such as protect the module from exposure to extreme conditions, or save or back
up data etc.
Level “+CMTE:-2”or “+CMTE:2” URCs are followed by immediate shutdown.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
231
2017-12-25
Smart Machine Smart Decision
10.7
AT+CPMVT Low and high voltage Power Off
Description
This command is used to open or close the low and high voltage power off function.
Vendor
FI
L
NO
References
E
SIM PIN
Syntax
Responses
+CPMVT: (list of supported <enable>s), (list of supported < low
voltage>s), (list of supported < high voltage>s)
OK
Read Command
AT+CPMVT?
Responses
+CPMVT: <enable>,<low voltage>, <high voltage>
OK
Write Command
AT+CPMVT=<enable>[,<low
voltage>],[<high voltage>]
Responses
OK
D
N
FI
ERROR
EN
TI
AL
Test Command
AT+CPMVT=?
O
Defined values
M
C
O
M
C
<enable>
0 – Close
1 – Open. If voltage < < low voltage>, it will report “UNDER-VOLTAGE WARNNING
POWER DOWN” and power off the module. If voltage > <high voltage>, it will report
“OVER-VOLTAGE WARNNING POWER DOWN” and power off the module
<low voltage>
Between 3200mV and 4000mV. Default value is 3200.
<high voltage>
Between 4000mV and 4300mV. Default value is 4300.
NOTE:The three parameters will be saved automatically.
SI
Examples
AT+CPMVT=1,3400,4300
OK
AT+CPMVT?
+CPMVT: 1,3400,4300
OK
AT+CPMVT=?
SIM7500_SIM7600 Series_AT Command Manual_V1.07
232
2017-12-25
Smart Machine Smart Decision
+CPMVT: (0-1),(3200-4000),(4000-4300)
OK
Description
This command is used to set the module go to recovery mode.
NO
References
AL
SIM PIN
Vendor
TI
Syntax
Responses
OK
EN
Write Command
AT+CDELTA
E
AT+CDELTA Set the module go to recovery mode
FI
L
10.8
D
ERROR
FI
Defined values
O
N
NOTE:the command will write flag to the module and reboot the module, then the module will
reboot and read the flag and enter recovery mode to update the firmware.
AT+CRIIC Read values from register of IIC device
C
10.9
O
M
AT+CDELTA
OK
C
Examples
M
Description
SI
This command is used to read values from register of IIC device.
SIM PIN
NO
References
Vendor
Syntax
Test Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
233
2017-12-25
Smart Machine Smart Decision
AT+CRIIC=?
OK
Write Command
AT+CRIIC=
<addr>,<reg>,<len>
Responses
+CRIIC: <data>
OK
E
ERROR
AL
TI
EN
<addr>
Device address. Input format must be hex, such as 0xFF.
<reg>
Register address. Input format must be hex, such as 0xFF.
<len>
Read length. Range:1-4; unit:byte.
<data>
Data read. Input format must be hex, such as 0xFF.
FI
L
Defined values
D
Examples
N
FI
AT+CRIIC=0x34, 0x02, 2
+CRIIC: 0x01,0x5d
OK
O
10.10 AT+CWIIC Write values to register of IIC device
C
Description
This command is used to write values to register of IIC device.
Vendor
O
NO
References
M
SIM PIN
C
Syntax
Responses
OK
Write Command
AT+CWIIC=
<addr>,<reg>,<data>,<len>
Responses
OK
SI
M
Test Command
AT+CWIIC=?
ERROR
Defined values
<addr>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
234
2017-12-25
Smart Machine Smart Decision
FI
L
E
Device address. Input format must be hex, such as 0xFF.
<reg>
Register address. Input format must be hex, such as 0xFF.
<len>
Read length. Range: 1-4; unit: byte.
<data>
Data written. Input format must be hex, such as 0xFF – 0xFFFFFFFF.
Examples
AL
AT+CWIIC=0x34, 0x03, 0x5d, 1
OK
TI
10.11 AT+CBC Read the voltage value of the power supply
EN
Description
This command is used to read the voltage value of the power supply
Vendor
FI
NO
References
D
SIM PIN
N
Syntax
Responses
+CBC: <vol>
OK
C
O
Read Command
AT+CBC
ERROR
M
Defined values
C
O
<vol>
The voltage value, such as 3.8.
M
Examples
SI
AT+CBC
+CBC: 3.591V
OK
10.12 AT+CPMUTEMP Read the temperature of the module
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
235
2017-12-25
Smart Machine Smart Decision
This command is used to read the temperature of the module
SIM PIN
NO
References
Vendor
Responses
+ CPMUTEMP: <temp>
OK
FI
L
Read Command
AT+CPMUTEMP
E
Syntax
AL
ERROR
Defined values
EN
TI
<temp>
The Temperature value, such as 29.
Examples
SI
M
C
O
M
C
O
N
FI
D
AT+CPMUTEMP
+CPMUTEMP: 29
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
236
2017-12-25
Smart Machine Smart Decision
11 AT Commands for SIM Application Toolkit
AT+STIN SAT Indication
E
11.1
FI
L
Description
Vendor
Syntax
D
YES
References
EN
SIM PIN
TI
AL
Every time the SIM Application issues a Proactive Command, via the ME, the TA will receive an
indication. This indicates the type of Proactive Command issued.
AT+STGI must then be used by the TA to request the parameters of the Proactive Command from
the ME. Upon receiving the +STGI response from the ME, the TA must send AT+STGR to confirm
the execution of the Proactive Command and provide any required user response, e.g. a selected
menu item.
Responses
OK
Read Command
AT+STIN?
Responses
+STIN: <cmd_id>
O
N
FI
Test Command
AT+STIN=?
C
OK
M
Unsolicited Result Codes
SI
M
C
O
+STIN: <cmd_id>
Proactive Command notification
21 – display text
22
– get inkey
23
– get input
24
– select item
+STIN: 25
Notification that SIM Application has returned to main menu. If user doesn’t do any action in 2
minutes, application will return to main menu automatically.
Defined values
<cmd_id>
21 – display text
22
– get inkey
SIM7500_SIM7600 Series_AT Command Manual_V1.07
237
2017-12-25
Smart Machine Smart Decision
–
–
–
–
–
get input
select item
set up menu
session end (pdu mode only)
none command
E
23
24
25
81
0
FI
L
Examples
AT+STGI Get SAT information
TI
11.2
AL
AT+STIN?
+STIN: 24
OK
Description
Vendor
Syntax
M
Test Command
AT+STGI=?
C
O
YES
References
N
SIM PIN
FI
D
EN
Regularly this command is used upon receipt of an URC "+STIN" to request the parameters of the
Proactive Command. Then the TA is expected to acknowledge the AT+STGI response with
AT+STGR to confirm that the Proactive Command has been executed. AT+STGR will also provide
any user information, e.g. a selected menu item. The Proactive Command type value specifies to
which "+STIN" the command is related.
NOTE: Please check the format refered to AT+STKFMT
Responses
OK
Responses
AT+STGI=<cmd_id>
PDU format
+STGI: <cmd_id>,<tag>,<pdu_len>,<pdu_value>
OK
C
O
Write Command
SI
M
AT+STGI=<cmd_id>
NOT PDU format, listed below:
If <cmd_id>=10:
OK
If <cmd_id>=21:
+STGI:21,<prio>,<clear_mode>,<text_len>,<text>
OK
If <cmd_id>=22:
+STGI: 22,< rsp_format>,< help>,<text_len>,<text>
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
238
2017-12-25
Smart Machine Smart Decision
If <cmd_id>=23:
+STGI:23,<rsp_format>,<max_len>,<min_len>,<help>,<show>,<t
ext_len>,<text>
OK
FI
L
E
If <cmd_id>=24:
+STGI:24,<help>,<softkey>,<present>,<title_len>,<title>,<item_n
um>
+STGI:24,<item_id>,<item_len>,<item_data>
[…]
OK
EN
TI
AL
If <cmd_id>=25:
+STGI:25,<help>,<softkey>,<title_len>,<title>,<item_num>
+STGI:25,<item_id>,<item_len>,<item_data>
[...]
OK
FI
SI
M
C
O
M
C
O
N
<cmd_id>
21 – display text
22 – get inkey
23 – get input
24 – select item
25
– set up menu
<prio>
Priority of display text
0 – Normal priority
1 – High priority
<clear_mode>
0 – Clear after a delay
1
– Clear by user
<text_len>
Length of text
<rsp_format>
0 – SMS default alphabet
1
– YES or NO
2 – numerical only
3
– UCS2
<help>
0 – Help unavailable
1
– Help available
<max_len>
Maximum length of input
D
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
239
2017-12-25
FI
L
AL
TI
EN
M
C
O
M
C
O
N
FI
D
<min_len>
Minimum length of input
<show>
0 – Hide input text
1
– Display input text
<softkey>
0 – No softkey preferred
1
– Softkey preferred
<present>
Menu presentation format available for select item
0 – Presentation not specified
1
– Data value presentation
2 – Navigation presentation
<title_len>
Length of title
<item_num>
Number of items in the menu
<item_id>
Identifier of item
<item_len>
Length of item
<title>
Title in ucs2 format
<item_data>
Content of the item in ucs2 format
<text>
Text in ucs2 format.
<tag>
Not used now.
<pdu_len>
Integer type, pdu string length
<pdu_value>
String type, the pdu string.
E
Smart Machine Smart Decision
Examples
SI
AT+STGI=25 (NOT PDU format)
+STGI:25,0,0,10,"795E5DDE884C59295730",15
+STGI:25,1,8,"8F7B677E95EE5019"
+STGI:25,2,8,"77ED4FE17FA453D1"
+STGI:25,3,8,"4F1860E05FEB8BAF"
+STGI:25,4,8,"4E1A52A17CBE9009"
+STGI:25,5,8,"8D448D3963A88350"
SIM7500_SIM7600 Series_AT Command Manual_V1.07
240
2017-12-25
Smart Machine Smart Decision
11.3
EN
TI
AL
FI
L
E
+STGI:25,6,8,"81EA52A9670D52A1"
+STGI:25,7,8,"8F7B677E5F6994C3"
+STGI:25,8,8,"8BED97F367425FD7"
+STGI:25,9,10,"97F34E506392884C699C"
+STGI:25,10,8,"65B095FB59296C14"
+STGI:25,11,8,"94C358F056FE7247"
+STGI:25,12,8,"804A59294EA453CB"
+STGI:25,13,8,"5F005FC34F1195F2"
+STGI:25,14,8,"751F6D3B5E388BC6"
+STGI:25,21,12,"00530049004D53614FE1606F"
OK
AT+STGI=24 (PDU format)
+STGI:24,0,48,"D02E81030124008202818285098070ED70B963A883508F0A018053057F574E0
78C618F0C02809177917777ED6D88606F"
OK
AT+STGR SAT respond
D
Description
YES
References
Vendor
C
SIM PIN
O
N
FI
The TA is expected to acknowledge the AT+STGI response with AT+STGR to confirm that the
Proactive Command has been executed. AT+STGR will also provide any user information, e.g. a
selected menu item.
NOTE: Please check the format refered to AT+STKFMT
M
Syntax
Responses
AT+STGR=?
OK
Write Command
Responses
C
O
Test Command
NOT PDU format
OK
AT+STGR=<pdu_len>,<pdu
_value>
PDU format
OK
SI
M
AT+STGR=<cmd_id>[,<dat
a>]
Defined values
<cmd_id>
22 – get inkey
23 – get input
SIM7500_SIM7600 Series_AT Command Manual_V1.07
241
2017-12-25
Smart Machine Smart Decision
Examples
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
24 – select item
25 – set up menu
81 – session end
83 – session end by user
84 – go backward
<data>
If <cmd_id>=22:
Input a character
If <cmd_id>=23:
Input a string.
If <rsp_format> is YES or NO, input of a character in case of ANSI character set requests one
byte, e.g. “Y”.
If <rsp_format> is numerical only, input the characters in decimal number, e.g. “123”
If <rsp_faomat> is UCS2, requests a 4 byte string, e.g. “0031”
<rsp_faomat> refer to the response by AT+STGI=23
If <cmd_id>=24:
Input the identifier of the item selected by user
If <cmd_id>=25:
Input the identifier of the item selected by user
If <cmd_id>=83:
<data> ignore
Note: It could return main menu during Proactive Command id is not 22 or 23
If <cmd_id>= 84:
<data> ignore
<pdu_len>
Integer type, pdu string length
<pdu_value>
String type, the pdu string.
SI
M
C
O
AT+STGR=25,1
(NOT PDU format)
OK
+STIN: 24
AT+STGR=30,"810301240002028281830100900101" (PDU format)
OK
11.4
AT+STK STK switch
Description
This command is used to disable or enable the STK function. If the argument is 1, it is enabled.
While if the argument is 0, it is disabled.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
242
2017-12-25
Smart Machine Smart Decision
SIM PIN
NO
References
Vendor
Syntax
Responses
+STK: (list of supported <value>s)
E
Test Command
AT+STK=?
Write Command
AT+STK=<value>
Responses
OK
AL
Responses
+STK: <value>
OK
TI
Read Command
AT+STK?
FI
L
OK
EN
ERROR
Responses
Set default value (<value>=0):
OK
D
Execution Command
AT+STK
N
O
C
<value>
0 – Disable STK
1 – Enable STK
FI
Defined values
Examples
O
AT+STKFMT Set STK pdu format
C
11.5
M
AT+STK=1
OK
M
Description
SI
This command is used to disable or enable the STK pdu mode. If the argument is 1, it is enabled.
While if the argument is 0, it is disabled.
NOTE: Module should reboot to take effective.
SIM PIN
YES
References
Vendor
Syntax
Read Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
243
2017-12-25
Smart Machine Smart Decision
AT+STKFMT?
+STKFMT: <value>
OK
Write Command
AT+STKFMT=<value>
Responses
OK
FI
L
E
ERROR
Defined values
TI
EN
Examples
D
AT+STKFMT=1
OK
AT+STENV Original STK PDU Envelope Command
FI
11.6
AL
<value>
0 – Disable STK pdu format, decoded command mode.
1 – Enable STK pdu format
NOTE: 7100 default value 0, 7500/7600 default value 1.
N
Description
Syntax
Vendor
M
YES
References
C
SIM PIN
C
O
Test Command
AT+STENV=?
M
Write Command
AT+STENV=<len>,<pdu>
SI
O
This command is used to original stk pdu envelope command.
NOTE: PDU format supported only.
Responses
OK
Responses
OK
ERROR
Defined values
<len>
Integer type, pdu string length
<pdu>
String type, pdu value
SIM7500_SIM7600 Series_AT Command Manual_V1.07
244
2017-12-25
Smart Machine Smart Decision
Examples
AT+STENV=18,"D30782020181900101"
OK
AT+STSM Get STK Setup Menu List with PDU Mode
E
11.7
FI
L
Description
This command is used to get the stk setup menu list with pdu mode
NOTE: PDU format supported only.
Vendor
TI
YES
References
AL
SIM PIN
EN
Syntax
Responses
OK
Read Command
AT+STSM?
Responses
+STSM: <cmd_id>,<tag>,<pdu_len>, <pdu_value>
OK
FI
D
Test Command
AT+STSM=?
N
ERROR
O
Defined values
C
O
M
C
<cmd_id>
Integer type, please refer to AT+STIN
<tag>
Not used now.
<pdu_len>
Integer type, pdu string length
<pdu_value>
String type, the pdu string.
M
Examples
SI
AT+STSM?
+STSM:25,0,120,"D07681030125008202818285078065B052BF529B8F0A018070ED70B963A883
508F06028070AB94C38F0A03806D41884C77ED4FE18F0A048081EA52A9670D52A18F0A0580
624B673A97F34E508F0606808D854FE18F0A07805A314E50753162118F0A0880767E53D8751F
6D3B8F0A09806D596C5F98919053"
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
245
2017-12-25
Smart Machine Smart Decision
12 AT Commands for Hardware
AT+IPREX Set local baud rate permanently
E
12.1
FI
L
Description
SIM PIN
References
Vendor
TI
NO
AL
This command sets the baud rate of module’s serial interface permanently, after reboot the baud rate
is also valid, if set to 0, then support autobaud, and the value of the IPR will be changed to current
baudrate when the autobaud is successful.
EN
Syntax
Responses
+IPREX: (list of supported<speed>s)
D
Test Command
AT+IPREX=?
OK
Responses
+IPREX: <speed>
N
FI
Read Command
AT+IPREX?
OK
C
ERROR
Responses
Set default value 115200:
OK
O
M
Execution Command
AT+IPREX
Responses
OK
O
Write Command
AT+IPREX=<speed>
C
Defined values
SI
M
<speed>
Baud rate per second:
0, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600,
3000000, 3200000, 3686400
Examples
AT+IPREX?
+IPREX: 115200
OK
AT+IPREX=?
SIM7500_SIM7600 Series_AT Command Manual_V1.07
246
2017-12-25
Smart Machine Smart Decision
12.2
AT+CFGRI
FI
L
E
+IPREX: (0,300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400,460800,921600,
3000000,3200000,3686400)
OK
AT+IPREX=115200
OK
AT+IPREX=0
OK
Indicate RI when using URC
AL
Description
NO
References
EN
SIM PIN
TI
This command is used to configure whether pulling down <URC time>milliseconds the RI pin of
UART when URC reported. If <status> is 1, host may be wake up by RI pin, add setting <URC
time>, <SMS time>pulling down time of RI pin.
Vendor
D
Syntax
Responses
+CFGRI: (range of supported <status>s), (range of supported
<URC time>s), (range of supported <SMS time>s)
OK
Responses
+CFGRI: <status>,<URC time>,<SMS time>
OK
Responses
OK
C
Read Command
AT+CFGRI?
O
N
FI
Test Command
AT+CFGRI=?
M
Write Command
AT+CFGRI=<status>,<URC
time>,<SMS time>
SI
M
C
O
Execution Command
AT+CFGRI
ERROR
Responses
Set <status> = 0
Set <URC time> = 60
Set <SMS time> = 120
OK
Defined values
<status>
0 off
1 on
<URC time>
a numeric parameter which is number of milliseconds to assert RI delay to reset RI. The range is
SIM7500_SIM7600 Series_AT Command Manual_V1.07
247
2017-12-25
Smart Machine Smart Decision
10 to 6000.
<SMS time>
a numeric parameter which is number of milliseconds to assert RI delay to reset RI. The range is
10 to 6000.
E
Examples
AL
TI
EN
AT+CSCLK Control UART Sleep
D
12.3
FI
L
AT+CFGRI=?
+CFGRI: (0-1),(10-6000),(20-6000)
OK
AT+CFGRI?
+CFGRI: 0,60,120
OK
AT+CFGRI=1
OK
AT+CFGRI
OK
FI
Description
SIM PIN
Vendor
O
Syntax
References
M
NO
C
O
N
This command is used to enable UART Sleep or always work,
if set to 1, UART can sleep when DTR pull high
if set to 0, UART always work
Write Command
AT+CSCLK=<status>
Responses
+CSCLK: (range of supported <status>s)
OK
Responses
+CSCLK: <status>
OK
Responses
OK
Execution Command
AT+CSCLK
ERROR
Responses
Set <status> = 0
M
C
Test Command
AT+CSCLK=?
SI
Read Command
AT+CSCLK?
SIM7500_SIM7600 Series_AT Command Manual_V1.07
248
2017-12-25
Smart Machine Smart Decision
OK
Defined values
FI
L
E
<status>
0 off
1 on
Examples
AT+CMUX
Enable the multiplexer over the UART
O
12.4
N
FI
D
EN
TI
AL
AT+CSCLK=?
+CSCLK: (0-1)
OK
AT+CSCLK?
+CSCLK: 0
OK
AT+CSCLK=1
OK
AT+CSCLK
OK
C
Description
O
M
This command is used to enable the multiplexer over the UART, after enabled four virtual ports can
be used as AT command port or MODEM port, the physical UART can no longer transfer data
directly under this case.
By default all of the four virtual ports are used as AT command port.
Second serial port is not support this command.
SIM PIN
Vendor
M
C
NO
References
SI
Syntax
Test Command
AT+CMUX=?
Responses
+CMUX: (0),(0),(1-8),(1-1500),(0),(0),(2-1000)
OK
Read Command
AT+CMUX?
Responses
+CMUX:<value>,<subset>,<port_speed>,<N1>,<T1>,<N2>,<T2>
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
249
2017-12-25
Smart Machine Smart Decision
Responses
OK
ERROR
E
Write Command
AT+CMUX=
<value>[,<subset>[,<port
_speed>[,<N1>[,<T1>[,
<N2>[,<T2>]]]]]]
AL
N
FI
D
EN
TI
< value >:
0 – currently only 0 is supported (basic operation mode).
< subset >:
Currently omitted
< port_speed >:
Currently omitted, you can set speed before enable multiplexer
< N1>:
1-1500
< T1>:
Currently omitted
< N2>:
Currently omitted
< T2>:
2-1000
FI
L
Defined values
O
Examples
SI
M
C
O
M
C
AT+CMUX=?
+CMUX: (0),(0),(1-8),(1-1500),(0),(0),(2-1000)
OK
AT+CMUX?
+CMUX: 0,0,5,1500,0,0,600
OK
AT+CMUX=0
OK
NOTE: Currently only basic operation mode is supported.
12.5
AT+CGFUNC Enable/disable the function for the special GPIO
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
250
2017-12-25
Smart Machine Smart Decision
SIM7500/SIM7600 supplies many GPIOs, all of which can be used as General Purpose
Input/Output pin, interrupt pin and some of them can be used as function pin.
This command is used to enable/disable the function for the special GPIO. Please consult the
document “SIM7500_SIM7600 Series_GPIO_Application_Note” for more details.
The configuration will be saved automatically.
Vendor
FI
L
NO
References
E
SIM PIN
Syntax
Responses
+CGFUNC: (list of supported <GPIO>s),(list of supported
<function>s)
OK
Read Command
Responses
AT+CGFUNC=<gpio>
+CGFUNC: <gpio>,<function>
OK
Responses
AT+CGFUNC=<gpio>,
<function>
OK
EN
FI
Write Command
D
ERROR
TI
AL
Test Command
AT+CGFUNC=?
Defined values
M
C
<GPIO>
7500C/CE GPIO:
40: GPIO40/STATUS
44: GPIO44/SD_DETECT
O
N
ERROR
C
O
7500A GPIO:
40: GPIO40/STATUS
SI
M
<FUNC>
0 : gpio function.
1 : function1
Examples
AT+CGFUNC=40,1
OK
AT+CGFUNC=40
SIM7500_SIM7600 Series_AT Command Manual_V1.07
251
2017-12-25
Smart Machine Smart Decision
+CGFUNC: 40,1
OK
AT+CGDRT Set the direction of specified GPIO
E
12.6
FI
L
Description
This command is used to set the specified GPIO to input or output state. If setting to input state,
then this GPIO can not be set to high or low value.
NO
References
AL
SIM PIN
Vendor
EN
TI
Syntax
Responses
+CGDRT: (list of supported <GPIO>s),(list of supported <
gpio_io >s)
OK
Write Command
AT+CGDRT=<GPIO>,
<gpio_io>
Responses
OK
N
O
ERROR
Responses
+ CGDRT: <GPIO>,<gpio_io>
OK
M
C
Read Command
AT+CGDRT=<GPIO>
FI
D
Test Command
AT+CGDRT=?
ERROR
O
Defined values
SI
M
C
<GPIO>
The value is GPIO ID, different hardware versions have different values.
<gpio_io>
0 – in
1 – out
Examples
AT+CGDRT=43,0
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
252
2017-12-25
Smart Machine Smart Decision
12.7
AT+CGSETV Set the value of specified GPIO
Description
This command is used to set the value of the specified GPIO to high or low.
Vendor
FI
L
NO
References
E
SIM PIN
Syntax
Responses
+CGSETV: (list of supported <GPIO>s),(list of supported <
gpio_hl >s)
OK
Write Command
Responses
AT+CGSETV=<GPIO>,<gp
io_hl>
OK
EN
TI
AL
Test Command
AT+CGSETV=?
D
ERROR
FI
Defined values
C
O
N
<GPIO>
The value is GPIO ID, different hardware versions have different values.
<gpio_hl>
0 – low
1 – high
Examples
C
O
M
AT+CGSETV=43,0
OK
AT+CGGETV Get the value of specified GPIO
M
12.8
SI
Description
This command is used to get the value (high or low) of the specified GPIO.
SIM PIN
NO
References
Vendor
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
253
2017-12-25
Smart Machine Smart Decision
Responses
+CGGETV: (list of supported <GPIO>s)
OK
Write Command
AT+CGGETV=<GPIO>
Responses
+CGGETV: <GPIO>,<gpio_hl>
OK
E
Test Command
AT+CGGETV=?
FI
L
ERROR
Defined values
EN
TI
AL
<GPIO>
The value is GPIO ID, different hardware versions have different values.
<gpio_hl>
0 – low
1 – high
NOTE: The GPIO must be set to GPIO FUNCTION through AT+CGFUNC, then it will set
success.
D
Examples
N
O
AT+CGISR Set GPIO interrupt trigger condition
C
12.9
FI
AT+CGGETV=43
+CGGETV: 43,0
OK
Description
M
C
O
M
The module supplies many GPIOs, all of which can be used as General Purpose Input/Oupt pin,
interrupt pin and some of them can be used as function pin.
This command is used to set one GPIO pin as an interrupt source, and then set the detect
type[optional] and polarity type[optional], and enable interrupt. Please consult the document
“SIM7500_SIM7600 Series_GPIO_Application_Note” for more details.
SI
SIM PIN
References
No
Syntax
Test Command
AT+CGISR=?
Responses
+CGISR: (list of supported <GPIO>s), <detect>,<polarity>,<URC
char [size(49)]>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
254
2017-12-25
Smart Machine Smart Decision
Responses
AT+CGISR=<GPIO>
opened:
+CGISR: < GPIO >,<detect>,<polarity>,<URC>
not opened:
+CGISR: < GPIO >,< detect >
OK
Write Command
Responses
AT+CGISR=<GPIO >,<dete
ct>,<polarity>,[<URC>]
OK
AL
FI
L
Read Command
E
OK
Defined values
TI
< GPIO >
D
FI
N
O
< detect >
0 – no detect.
1 – level detection
2 – edge detection
< polarity >
0 – low level/edge detection
1 – high level/edge detection
<URC >
Your ISR string
EN
The value is GPIO ID, different hardware versions have different values.
C
Examples
SI
M
C
O
M
AT+CGISR=41
+CGISR : 41,1,1,GPIO_41_ISR! If the pin ISR is opened
OK
+CGISR : 41,0 If the pin ISR is not opened
OK
AT+CGISR=41,0,1
OK
NOTE:
1. if the interruption is triggered SIM7500/SIM7600 will send the following URC to host, URC is your
ISR string or GPIO_< GPIO >_ISR
2.
Default <detect> is 0 and default <polarity> is 1.
3.
After setting one GPIO pin as an interrupt source successfully, the setting will be saved.
4.
If the gpio use to interruption,before the gpio mustbe config on GPIO function
SIM7500_SIM7600 Series_AT Command Manual_V1.07
255
2017-12-25
Smart Machine Smart Decision
13 AT Commands for File System
NOTE: General rules for naming (both directories and files):
1
The length of actual fully qualified names of directories and files can not exceed 254.
2
Directory and file names can not include the following characters:
“ < > | , ;
AL
\ : * ?
Between directory name and file/directory name, use character “/” as list separator, so it can not
appear in directory name or file name.
4
The first character of names must be a letter or a numeral or underline, and the last character can
not be period “.” and oblique “/”.
EN
TI
3
AT+FSCD Select directory as current directory
D
13.1
FI
L
Local storage space is mapped to “C:”, “D:” for TF card, “E:” for multimedia.
E
The file system is used to store files in a hierarchical (tree) structure, and there are some definitions and
conventions to use the Module.
FI
Description
Vendor
C
NO
References
O
SIM PIN
N
This command is used to select a directory. The Module supports absolute path and relative path.
Read Command will return current directory without double quotation marks.support SDcard.
Syntax
Responses
OK
Read Command
AT+FSCD?
Responses
+FSCD: <curr_path>
M
C
O
M
Test Command
AT+FSCD=?
SI
Write Command
AT+FSCD=<path>
OK
Responses
+FSCD: <curr_path>
OK
ERROR
Defined values
<path>
String without double quotes, directory for selection.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
256
2017-12-25
Smart Machine Smart Decision
NOTE: If <path> is “..”, it will go back to previous level of directory.
<curr_path>
String without double quotes, current directory.
Examples
FI
L
AL
TI
EN
D
FI
N
O
AT+FSMKDIR
Make new directory in current directory
C
13.2
E
AT+FSCD=C:
+FSCD: C:/
OK
AT+FSCD=C:/
+FSCD: C:/
OK
AT+FSCD?
+FSCD: C:/
OK
AT+FSCD=..
+FSCD: C:/
OK
AT+FSCD=D:
+FSCD: D:/
OK
AT+FSCD?
+FSCD:D:/
OK
Description
M
This command is used to create a new directory in current directory.Support SDcard.
SIM PIN
Vendor
C
O
NO
References
M
Syntax
Responses
OK
Write Command
AT+FSMKDIR=<dir>
Responses
OK
SI
Test Command
AT+FSMKDIR=?
ERROR
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
257
2017-12-25
Smart Machine Smart Decision
<dir>
String without double quotes, directory name which does not already exist in current directory.
Examples
AL
FI
L
E
AT+FSMKDIR= SIMTech
OK
AT+FSCD?
+FSCD: C:/
OK
AT+FSLS
+FSLS: SUBDIRECTORIES:
SIMTech
AT+FSRMDIR
EN
13.3
TI
OK
Delete directory in current directory
D
Description
SIM PIN
References
N
Vendor
O
NO
FI
This command is used to delete existing directory in current directory. Support SDcard.
Test Command
AT+FSRMDIR=?
C
Syntax
Responses
OK
ERROR
C
O
M
Write Command
AT+FSRMDIR=<dir>
Responses
OK
M
Defined values
SI
<dir>
String without double quotes.
Examples
AT+FSRMDIR=SIMTech
OK
AT+FSCD?
+FSCD: C:/
SIM7500_SIM7600 Series_AT Command Manual_V1.07
258
2017-12-25
Smart Machine Smart Decision
FI
L
AT+FSLS List directories/files in current directory
AL
13.4
E
OK
AT+FSLS
+FSLS: SUBDIRECTORIES:
Audio
Picture
Video
VideoCall
OK
Description
NO
References
EN
SIM PIN
TI
This command is used to list informations of directories and/or files in current directory. Support
SDcard.
Vendor
D
Syntax
Responses
+FSLS: (list of supported <type>s)
OK
Read Command
AT+FSLS?
Responses
+FSLS: SUBDIRECTORIES:<dir_num>,FILES:<file_num>
O
N
FI
Test Command
AT+FSLS=?
M
C
O
M
Write Command
AT+FSLS=<type>
C
OK
SI
Execution Command
AT+FSLS
Responses
[+FSLS: SUBDIRECTORIES:
<list of subdirectories>
<CR><LF>]
[+FSLS: FILES:
<list of files>
<CR><LF>]
OK
Responses
[+FSLS: SUBDIRECTORIES:
<list of subdirectories>
<CR><LF>]
[+FSLS: FILES:
<list of files>
<CR><LF>]
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
259
2017-12-25
Smart Machine Smart Decision
Defined values
FI
L
E
<dir_num>
Integer type, the number of subdirectories in current directory.
<file_num>
Integer type, the number of files in current directory.
<type>
0 – list both subdirectories and files
1 – list subdirectories only
2 – list files only
AL
Examples
EN
D
N
O
C
AT+FSDEL Delete file in current directory
M
C
13.5
O
OK
M
OK
AT+FSLS=2
+FSLS: FILES:
image_0.jpg
image_1.jpg
FI
+FSLS: FILES:
image_0.jpg
image_1.jpg
TI
AT+FSLS?
+FSLS: SUBDIRECTORIES:2,FILES:2
OK
AT+FSLS
+FSLS: SUBDIRECTORIES:
FirstDir
SecondDir
SI
Description
This command is used to delete a file in current directory. Before do that, it needs to use AT+FSCD
select the father directory as current directory. Support SDcard.
SIM PIN
NO
References
Vendor
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
260
2017-12-25
Smart Machine Smart Decision
Test Command
Responses
AT+FSDEL=?
OK
Write Command
AT+FSDEL=<filename>
Responses
OK
E
ERROR
FI
L
Defined values
TI
AL
<filename>
String with or without double quotes, file name which is relative and already existing.
If <filename> is *.*, it means delete all files in current directory.
If the file path contains non-ASCII characters, the filename parameter should contain a prefix of
{non-ascii} and the quotation mark.
EN
Examples
AT+FSRENAME
N
Description
Rename file in current directory
FI
13.6
D
AT+FSDEL=image_0.jpg
OK
Syntax
Vendor
M
NO
References
C
SIM PIN
O
This command is used to rename a file in current directory.
Responses
OK
Write Command
AT+FSRENAME=
<old_name>,<new_name>
Responses
OK
ERROR
SI
M
C
O
Test Command
AT+FSRENAME=?
Defined values
<old_name>
String with or without double quotes, file name which is existed in current directory. If the file path
contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii} and
the quotation mark.
<new_name>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
261
2017-12-25
Smart Machine Smart Decision
New name of specified file, string with or without double quotes. If the file path contains
non-ASCII characters, the file path parameter should contain a prefix of {non-ascii} and the
quotation mark.
FI
L
AT+FSRENAME=image_0.jpg, image_1.jpg
OK
AT+FSRENAME= "my test.jpg", {non-ascii}"E6B58BE8AF95E99984E4BBB62E6A7067"
OK
E
Examples
AT+FSATTRI
Request file attributes
TI
Description
AL
13.7
SIM PIN
References
Vendor
D
NO
EN
This command is used to request the attributes of file which exists in current directory.
FI
Syntax
Responses
AT+FSATTRI=?
OK
Write Command
AT+FSATTRI=<filename>
Responses
+FSATTRI: <file_size>, <create_date>
C
O
N
Test Command
OK
M
Defined values
SI
M
C
O
<filename>
String with or without double quotes, file name which is in current directory. If the file path
contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii} and
the quotation mark.
<file_size>
The size of specified file, and the unit is in Byte.
<create_date>
Create date and time of specified file, the format is YYYY/MM/DD HH/MM/SS Week.
Week – Mon, Tue, Wed, Thu, Fri, Sat, Sun
Examples
AT+FSATTRI=image_0.jpg
+FSATTRI: 8604, 2008/04/28 10:24:46 Tue
SIM7500_SIM7600 Series_AT Command Manual_V1.07
262
2017-12-25
Smart Machine Smart Decision
OK
AT+FSATTRI={non-ascii}"E6B58BE8AF95E99984E4BBB62E6A7067"
+FSATTRI: 6296, 2012/01/06 00:00:00 Sun
OK
E
AT+FSMEM Check the size of available memory
FI
L
13.8
Description
This command is used to check the size of available memory. The response will list total size and
used size of local storage space if present and mounted.
Vendor
TI
NO
References
AL
SIM PIN
EN
Syntax
Responses
OK
Execution Command
Responses
AT+FSMEM
+FSMEM: C:(<total>, <used>)
FI
N
OK
D
Test Command
AT+FSMEM=?
O
Defined values
O
Examples
M
C
<total>
The total size of local storage space.
<used>
The used size of local storage space.
NOTE: The unit of storage space size is in Byte.
SI
M
C
AT+FSMEM
+FSMEM: C:(11348480, 2201600)
OK
13.9
AT+FSLOCA Select storage place
Description
This command is used to set the storage place for media files.
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
263
2017-12-25
Smart Machine Smart Decision
NO
Vendor
Responses
+FSLOCA: (list of supported <loca>s)
OK
Read Command
AT+FSLOCA?
Responses
+FSLOCA: <loca>
FI
L
Test Command
AT+FSLOCA=?
E
Syntax
OK
Responses
OK
AL
Write Command
AT+FSLOCA=<loca>
TI
ERROR
store media files to local storage space (namely “C:/”)
D
<loca>
0 –
EN
Defined values
N
O
C
AT+FSLOCA=0
OK
AT+FSLOCA?
+FSLOCA: 0
OK
FI
Examples
M
13.10 AT+FSCOPY Copy an appointed file
O
Description
C
This command is used to copy an appointed file on C:/ to an appointed directory on C:/, the new file
name should give in parameter.
M
SIM PIN
Vendor
SI
NO
References
Syntax
Test Command
AT+FSCOPY=?
Responses
OK
Write Command
AT+FSCOPY=<file1>,<file
Responses
+FSCOPY: <percent>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
264
2017-12-25
Smart Machine Smart Decision
2>[<sync_mode>]
[+FSCOPY: <percent>]
OK
FI
L
N
FI
D
EN
TI
AL
If found any error:
SD CARD NOT PLUGGED IN
FILE IS EXISTING
FILE NOT EXISTING
DIRECTORY IS EXISTED
DIRECTORY NOT EXISTED
FORBID CREATE DIRECTORY UNDER \"C:/\"
FORBID DELETE DIRECTORY
INVALID PATH NAME
INVALID FILE NAME
SD CARD HAVE NO ENOUGH MEMORY
EFS HAVE NO ENOUGH MEMORY
FILE CREATE ERROR
READ FILE ERROR
WRITE FILE ERROR
ERROR
E
OK
+FSCOPY: <percent>
[+FSCOPY: <percent>]
+FSCOPY: END
O
Defined values
SI
M
C
O
M
C
<file1>
The sources file name or the whole path name with sources file name. If the file path contains
non-ASCII characters, the file path parameter should contain a prefix of {non-ascii} and the
quotation mark.
<file2>
The destination file name or the whole path name with destination file name. If the file path
contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii} and
the quotation mark.
<percent>
The percent of copy done. The range is 0.0 to 100.0
<sync_mode>
The execution mode of the command:
0 – synchronous mode
1 – asynchronous mode
NOTE:
1. The <file1> and <file2> should give the whole path and name, if only given file name, it will
refer to current path (AT+FSCD) and check the file’s validity.
2. If <file2> is a whole path and name, make sure the directory exists, make sure that the file
SIM7500_SIM7600 Series_AT Command Manual_V1.07
265
2017-12-25
Smart Machine Smart Decision
E
name does not exist or the file name is not the same name as the sub folder name, otherwise return
error.
3. <percent> report refer to the copy file size. The big file maybe report many times, and little
file report less.
4. If <sync_mode> is 1, the command will return OK immediately, and report final result with
+FSCOPY: END.
FI
L
Examples
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
AT+FSCD?
+FSCD: C:/
OK
AT+FSCOPY= C:/TESTFILE,COPYFILE (Copy file TESTFILE on C:/ to C:/COPYFILE)
+FSCOPY: 1.0
+FSCOPY: 9.7
+FSCOPY: 19.4
…
+FSCOPY: 100.0
OK
AT+FSCOPY= "my test.jpg", {non-ascii}"E6B58BE8AF95E99984E4BBB62E6A7067"
+FSCOPY:1.0
+FSCOPY:100.0
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
266
2017-12-25
Smart Machine Smart Decision
14 AT Commands for File Transmission
Transfer a file to EFS
E
AT+CFTRANRX
FI
L
14.1
Description
This command is used to transfer a file to EFS.Support SDcard.
NO
References
AL
SIM PIN
Vendor
TI
Syntax
Write Command
Responses
+CFTRANRX: [{non-ascii}]"FILEPATH"
OK
Responses
AT+CFTRANRX=“<filepat
h>”,<len>
>
OK
FI
D
EN
Test Command
AT+CFTRANRX=?
O
N
>
ERROR
Defined values
C
ERROR
M
C
O
M
<filepath>
The path of the file on EFS.
<len>
The length of the file data to send.
NOTE
The <filepath> must be a full path with the directory path.
SI
Examples
AT+CFTRANRX=”c:/MyDir/t1.txt”,10
>testcontent
OK
AT+CFTRANRX=”d:/MyDir/t1.txt”,10
>testcontent
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
267
2017-12-25
Smart Machine Smart Decision
14.2
AT+CFTRANTX Transfer a file from EFS to host
Description
Vendor
FI
L
NO
E
This command is used to transfer a file from EFS to host. Before using this command, the
AT+CATR must be used to set the correct port used. Support SDcard.
SIM PIN References
AL
Syntax
Responses
+CFTRANTX: [{non-ascii}]"FILEPATH"
OK
Responses
Write Command
[+CFTRANTX: DATA,<len>
…
+CFTRANTX: DATA,<len>]
+CFTRANTX: 0
OK
FI
D
AT+CFTRANTX=“<filepath
>”[,<location>,<size>]
EN
TI
Test Command
AT+CFTRANTX=?
N
ERROR
O
Defined values
M
C
O
M
C
<filepath>
The path of the file on EFS.
<len>
The length of the following file data to output.
<location>
The beginning of the file data to output.
<size>
The length of the file data to output.
NOTE
The <filepath> must be a full path with the directory path.
SI
Examples
AT+CFTRANTX=”c:/MyDir/t1.txt”
+CFTRANTX: DATA, 11
Testcontent
+CFTRANTX: 0
OK
AT+CFTRANTX=”d:/MyDir/t1.txt”
SIM7500_SIM7600 Series_AT Command Manual_V1.07
268
2017-12-25
Smart Machine Smart Decision
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
+CFTRANTX: DATA, 11
Testcontent
+CFTRANTX: 0
OK
AT+CFTRANTX=”d:/MyDir/t1.txt”,1,4
+CFTRANTX: DATA, 4
estc
+CFTRANTX: 0
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
269
2017-12-25
Smart Machine Smart Decision
15 AT Commands for Internet Service
E
PDP
15.1.1 AT+CSOCKSETPN
FI
L
15.1
Set active PDP context’s profile number
AL
Description
YES
References
EN
SIM PIN
TI
This command sets default active PDP context’s profile number. When we activate PDP by using
AT+NETOPEN command, we need use the default profile number, and the context of this profile is
set by AT+CGCONT command.
Vendor
D
Syntax
Responses
+CSOCKSETPN: (list of supported <profile_number>s)
N
OK
FI
Test Command
AT+CSOCKSETPN=?
Responses
+CSOCKSETPN: <profile_number>
OK
C
Read Command
AT+CSOCKSETPN?
O
ERROR
M
ERROR
O
Write Command
AT+CSOCKSETPN=<profil
e_number>
ERROR
Responses
OK
ERROR
SI
M
C
Execution Command
AT+CSOCKSETPN
Responses
OK
Defined values
<profile_number>
A numeric parameter that identifies default profile number, the range of permitted values is one to
sixteen.
1…24,100…179
SIM7500_SIM7600 Series_AT Command Manual_V1.07
270
2017-12-25
Smart Machine Smart Decision
Examples
AT+CSOCKSETPN=1
OK
Set DNS query parameters
E
15.1.2 AT+CIPDNSSET
FI
L
Description
SIM PIN
References
TI
Vendor
EN
NO
AL
This command is used to set DNS query parameters. The timeout value for performing DNS query
is <net_open_time> + 3000ms + 1000ms*<dns_query_retry_counter>. Here <net_open_time> is
the time for opening PS network. <dns_query_retry_counter> is the retry counter for sending DNS
query using UDP packet.
Syntax
Responses
OK
Read Command
AT+CIPDNSSET?
Responses
+CIPDNSSET:
<max_net_retries>,<net_timeout>,<max_query_retries>
O
N
FI
D
Test Command
AT+CIPDNSSET=?
OK
Responses
C
Write Command
OK
ERROR
O
M
AT+CIPDNSSET=[<ma
x_net_retries>][,
[<net_timeout>][,
[<max_query_retries>]]]
C
Defined values
SI
M
<max_net_retries>
Maxmimum retry times for opening PS network to perform DNS query. The range is from 0 to 3.
Default value is 3.
<net_timeout>
Timeout value for each opening PS network operation when performing DNS query. The range is
from 3000ms to 120000ms. Default value is 30000ms.
<max_query_retries>
Maximum retry times for performing DNS query using UDP packet. The range is from 0 to 7.
Default value is 7.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
271
2017-12-25
Smart Machine Smart Decision
Examples
AT+CIPDNSSET?
+CIPDNSSET: 1,30000,3
FI
L
AT+CDNSGIP Query the IP address of given domain name
Description
SIM PIN
References
Vendor
EN
YES
TI
This command is used to query the IP address of given domain name.
AL
15.1.3
E
OK
AT+CIPDNSSET=1,30000,1
OK
Responses
OK
FI
Test Command
AT+CDNSGIP=?
D
Syntax
O
Responses
If successful,return:
+CDNSGIP: 1,<domain name>,<IP address>
OK
If fail,return:
+CDNSGIP: 0,<dns error code>
ERROR
ERROR
O
M
C
Write Command
AT+CDNSGIP=<domain
name>
N
ERROR
C
Defined values
SI
M
<domain name>
A string parameter (string should be included in quotation marks) which indicates the do
ma-in name.
<IP address>
A string parameter (string should be included in quotation marks) which indicates the IP
address corresponding to the domain name.
<dns error code>
A numeric parameter which indicates the error code.
10 DNS GENERAL ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
272
2017-12-25
Smart Machine Smart Decision
Examples
FI
L
AT+CDNSGHNAME
15.1.4
E
AT+CDNSGIP=?
OK
AT+CDNSGIP=”www.google.com”
+CDNSGIP: 1,"www.google.com","203.208.39.99"
OK
Query the domain name of given IP
Description
Vendor
Syntax
Responses
OK
FI
Test Command
AT+CDNSGHNAME=?
D
YES
References
EN
SIM PIN
TI
This command is used to query the domain name of given IP address.
AL
address
O
Responses
If successful,return:
+CDNSGHNAME: <index>,<domain name>,<IP address>
OK
If fail,return:
+CDNSGHNAME: 0,<dns error code>
ERROR
ERROR
C
O
M
C
Write Command
AT+CDNSGHNAME=<IP
address>
N
ERROR
M
Defined values
SI
<domain name>
A string parameter (string should be included in quotation marks) which indicates the do
ma-in name.
<IP address>
A string parameter (string should be included in quotation marks) which indicates the IP
address corresponding to the domain name.
<dns error code>
A numeric parameter which indicates the error code.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
273
2017-12-25
Smart Machine Smart Decision
10 DNS GENERAL ERROR
<index>
A numeric parameter which indicates DNS result index. This value is always 1 if performing
successfully. Currently only the first record returned from the DNS server will be reported.
E
Examples
AL
FI
L
AT+CDNSGHNAME=?
OK
AT+CDNSGHNAME=” 58.32.231.148”
+CDNSGHNAME: 1,"mail.sim.com","58.32.231.148"
AT+CPING Ping destination address
Description
SIM PIN
References
Vendor
FI
YES
D
This command is used to ping destination address.
O
C
M
Test Command
AT+CPING=?
O
N
Syntax
M
C
Write Command
AT+CPING=<dest_addr>,<dest_ad
dr_type>
[,<num_pings>[,<data_packet_size
>[,<interval_time>[,<wait_time>
[,<TTL>]]]]]
SI
EN
15.1.5
TI
OK
Responses
+CPING:
IP
address,
(list
of
supported
<dest_addr_type>s),(1-100),(4-188),(1000-10000),(10000-1
00000), (16-255)
OK
ERROR
Responses
OK
If ping’s result_type = 1
+CPING:
<result_type>,<resolved_ip_addr>,<data_packet_size>,<rtt>,
<TTL>
If ping’s result_type = 2
+CPING: <result_type>
If ping’s result_type = 3
SIM7500_SIM7600 Series_AT Command Manual_V1.07
274
2017-12-25
Smart Machine Smart Decision
+CPING:
<result_type>,<num_pkts_sent>,<num_pkts_recvd>,<num_p
kts_lost>,<min_rtt>,<max_rtt>,<avg_rtt>
ERROR
E
Defined values
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
<dest_addr>
The destination is to be pinged; it can be an IP address or a domain name.
<dest_addr_type>
Integer type. Address family type of the destination address
1 – IPv4.
2 – IPv6(reserved)
<num_pings>
Integer type. The num_pings specifies the number of times the ping request (1-100) is to be sent.
The default value is 4.
<data_packet_size>
Integer type. Data byte size of the ping packet (4-188). The default value is 64 bytes.
<interval_time>
Integer type. Interval between each ping. Value is specified in milliseconds (1000ms-10000ms). The
default value is 2000ms.
<wait_time>
Integer type. Wait time for ping response. An ping response received after the timeout shall not be
processed. Value specified in milliseconds (10000ms-100000ms). The default value is 10000ms.
<TTL>
Integer type. TTL(Time-To-Live) value for the IP packet over which the ping(ICMP ECHO
Request message) is sent (16-255), the default value is 255.
<result_type>
1 – Ping success
2 – Ping time out
3 – Ping result
<num_pkts_sent>
Indicates the number of ping requests that were sent out.
<num_pkts_recvd>
Indicates the number of ping responses that were received.
<num_pkts_lost>
Indicates the number of ping requests for which no response was received.
<min_rtt>
Indicates the minimum Round Trip Time(RTT).
<max_rtt>
Indicates the maximum RTT.
<avg_rtt>
Indicates the average RTT.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
275
2017-12-25
Smart Machine Smart Decision
<resolved_ip_addr>
Indicates the resolved ip address.
< rtt>
Round Trip Time.
AL
FI
L
AT+CPING=?
+CPING:IP address,(1,2), (1-100), (4-188),(1000-10000),(10000-100000), (16-255)
OK
AT+CPING="www.baidu.com",1,4,64,1000,10000,255
OK
E
Examples
TI
+CPING: 1,119.75.217.56,64,410,255
EN
+CPING: 1,119.75.217.56,64,347,255
+CPING: 1,119.75.217.56,64,346,255
FI
N
+CPING: 3,4,4,0,346,444,386
AT+CPINGSTOP
Stop an ongoing ping session
O
15.1.6
D
+CPING: 1,119.75.217.56,64,444,255
C
Description
This command is used to stop an ongoing ping session.
Vendor
O
YES
References
M
SIM PIN
C
Syntax
Responses
OK
Write Command
AT+CPINGSTOP
Responses
+CPING:
<result_type>,<num_pkts_sent>,<num_pkts_recvd>,<num_p
kts_lost>,<min_rtt>,<max_rtt>,<avg_rtt>
OK
SI
M
Test Command
AT+CPINGSTOP=?
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
276
2017-12-25
Smart Machine Smart Decision
FI
L
FI
D
EN
TI
AL
<result_type>
1 – Ping success
2 – Ping time out
3 – Ping result
<num_pkts_sent>
Indicates the number of ping requests that were sent out.
<num_pkts_recvd>
Indicates the number of ping responses that were received.
<num_pkts_lost>
Indicates the number of ping requests for which no response was received.
<resolved_ip_addr>
Indicates the resolved ip address.
<min_rtt>
Indicates the minimum Round Trip Time (RTT).
<max_rtt>
Indicates the maximum RTT.
<avg_rtt>
Indicates the average RTT.
E
Defined values
Examples
O
AT+CTCPFIN Configure TCP FIN
C
15.1.7
N
AT+CPINGSTOP
OK
Description
O
M
This command is used to configure whether the module should wait for TCP_FIN in
TCP_FINWAIT2 state.
SIM PIN
Vendor
M
C
YES
References
SI
Syntax
Test Command
AT+CTCPFIN=?
Responses
+CTCPFIN: (list of supported <TCP_FIN_Enable>s)
OK
ERROR
Read Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
277
2017-12-25
Smart Machine Smart Decision
AT+CTCPFIN?
+CTCPFIN:<TCP_FIN_Enable>
OK
ERROR
Write Command
Responses
AT+CTCPFIN=<TCP_FIN_
Enable>
OK
FI
L
E
ERROR
Defined values
TI
AL
< TCP_FIN_Enable >
a numeric parameter which sets whether waiting for TCP_FIN inTCP_FINWAIT2 state.
0 not waiting
1 waiting
EN
Examples
FI
N
AT+CTCPKA Conigure TCP heartbeat
O
15.1.8
D
AT+CTCPFIN=?
+CTCPFIN: (0,1)
OK
AT+CTCPFIN=1
OK
C
Description
This command is used to set TCP heartbeat parameters..
YES
Vendor
O
Syntax
References
M
SIM PIN
SI
M
C
Test Command
AT+CTCPKA=?
Responses
+CTCPKA: (list of supported <TCP_KA_Enable>s),(list of
supported
<KeepIdleTm>s)
,(list
of
supported
<KeepAliveMaxTry>s)
OK
Read Command
Responses
AT+CTCPKA?
+CTCPKA:<TCP_KA_Enable>,<KeepIdleTm>,<KeepAliveMaxT
ry>
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
278
2017-12-25
Smart Machine Smart Decision
Write Command
Responses
AT+CTCPKA=<TCP_KA_
Enable>,<KeepIdleTm>,<Ke
epAliveMaxTry>
OK
ERROR
FI
L
E
Defined values
EN
TI
AL
< TCP_KA_Enable >
a numeric parameter which sets whether enable TCP heartbeat function or not.
0 disable
1 enable
<KeepIdleTm>
a numeric parameter which is number of minutes to delay after last time of sending TCP data. The
range is 1 to 120.
<KeepAliveMaxTry>
Maximum times for sending Keep-Alive checking. The range is 1 to 10.
FI
N
AT+CTEUTP Set unknown incoming TCP packet echo
C
15.1.9
O
AT+CTCPKA=?
+CTCPKA: (0,1),(1-120) ,(1-10)
OK
AT+CTCPKA=1,3,3
OK
D
Examples
Description
M
This command is used to enable or disable unknown incoming TCP packet echo.
References
O
SIM PIN
Vendor
C
YES
M
Syntax
SI
Test Command
AT+CTEUTP=?
Responses
+CTEUTP: (list of supported <Echo_Unknown_TCP_Enable>s)
OK
ERROR
Read Command
Responses
AT+CTEUTP?
+CTEUTP:<Echo_Unknown_TCP_Enable>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
279
2017-12-25
Smart Machine Smart Decision
OK
ERROR
Write Command
Responses
AT+CTEUTP=<Echo_Unkn
own_TCP_Enable>
OK
E
ERROR
FI
L
Defined values
TI
AL
<Echo_Unknown_TCP_Enable>
a numeric parameter which sets whether enable or disable unknown incoming TCP packet echo
option.
0 disable
1 enable
EN
Examples
N
Set UDP port unreachable ICMP echo
O
15.1.10 AT+CUPURE
FI
D
AT+CTEUTP=?
+CTEUTP: (0,1)
OK
AT+CTEUTP=1
OK
C
Description
This command is used to enable or disable UDP port unreachable echo.
YES
Vendor
O
Syntax
References
M
SIM PIN
SI
M
C
Test Command
AT+CUPURE=?
Responses
+CUPURE:
(list
of
<UDP_PORT_UNREACHABLE_Enable>s)
supported
OK
ERROR
Read Command
Responses
AT+CUPURE?
+CUPURE:< UDP_PORT_UNREACHABLE_Enable>
OK
ERROR
Write Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
280
2017-12-25
Smart Machine Smart Decision
AT+CUPURE=<UDP_POR
T_UNREACHABLE_Enabl
e>
OK
ERROR
E
Defined values
AL
FI
L
<UDP_PORT_UNREACHABLE_Enable>
a numeric parameter which sets whether enable or disable UDP port unreachable ICMP echo
option.
0 disable
1 enable
Examples
Preferred ICMP filter
FI
15.1.11 AT+CINICMPALLOW
D
EN
TI
AT+CUPURE=?
+CUPURE: (0,1)
OK
AT+CUPURE=1
OK
N
Description
Syntax
Vendor
M
YES
References
C
SIM PIN
O
This command is used to filter the incoming ICMP packets that are not allowed.
M
C
O
Test Command
AT+CINICMPALLOW=?
SI
Read Command
AT+CINICMPALLOW?
Responses
+ CINICMPALLOW: (list of supported <mode>s)
OK
ERROR
Responses
+CINICMPALLOW: <mode>
OK
ERROR
Write Command
Responses
AT+CINICMPALLOW=<m
ode>
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
281
2017-12-25
Smart Machine Smart Decision
FI
L
AL
O
N
FI
D
EN
TI
<mode>
64bit number, the value is “1” << “<pos>” , then or by bit.
<pos>
Flag value from 0 to 63.
Value:
0
ICMP ECHO REPLY
3
ICMP DESTINATION UNREACH
4
ICMP SOURCE QUENCH
5
ICMP REDIRECT
8
ICMP ECHO REQUEST
9
MIP AGENT ADVERTISEMENT
10
MIP AGENT SOLICITATION
11
TIME-TO-ALIVE EXCEEDED
12
PARAMETER PROBLEM
13
ICMP TIMESTAMP
14
ICMP TIME REPLY
15
INFORMATION REQUEST
16
INFORMATION REPLY
17
ADDRESS MASK REQUEST
18
ADDRESS MASK REPLY
37
DOMAIN NAME REQUEST
38
DOMAIN NAME REPLY
E
Defined values
C
Examples
O
M
AT+CINICMPALLOW=0xFFFFFFFFFFFFFEFF
OK
AT+CINICMPALLOW?
+CINICMPALLOW: 0xFFFFFFFFFFFFFEFF
OK
Get dns server ip address
M
C
15.1.12 AT+CDNSSRV
SI
Description
The write command is used to query the dns server ip address of the specified PDP context (s).
SIM PIN
YES
References
3GPP TS 27.007
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
282
2017-12-25
Smart Machine Smart Decision
E
Responses
[+CDNSSRV: [<cid>, <ip_addr>,<prm_dns>,<sec_dns>
[<CR><LF>
+ CDNSSRV: <cid>, <ip_addr>,<prm_dns>,<sec_dns>
[...]]]]
OK
FI
L
Read Command
AT+CDNSSRV?
Defined values
D
EN
TI
AL
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command).
1…24,100…179
<ip_addr>
A string that identifies the IP address when the PDP context is activaed.
<pri_dns>
A string that identifies the primary DNS server address when the PDP context is activaed.
<sec_dns>
A string that identifies the secondary DNS server address when the PDP context is activaed.
FI
Examples
TCP/UDP
AT+CIPCCFG Configure parameters of socket
O
15.2.1
M
15.2
C
O
N
AT+CDNSSRV?
+CDNSSRV: 1, "10.85.202.25","210.22.70.3","211.95.1.97"
OK
Description
M
C
This command is used to configure parameters of socket. For the write command, the parameter
part cannot be empty.
SIM PIN
SI
YES
References
Vendor
Syntax
Test Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
283
2017-12-25
Smart Machine Smart Decision
AT+CIPCCFG=?
+CIPCCFG: (list of supported <NmRetry>s),(list of supported
<DelayTm>s),(list of supported <Ack>s),(list of supported
<errMode>s),(list of supported <HeaderType>s), (list of supported
<AsyncMode>s), (list of supported <TimeoutVal>s)
E
OK
FI
L
ERROR
Responses
AT+CIPCCFG?
+CIPCCFG:<NmRetry>,<DelayTm>,<Ack>,<errMode>,<HeaderType>,<AsyncMode>,<TimeoutVal>
OK
AL
Read Command
ERROR
Responses
AT+CIPCCFG=[<NmRetry>
][,[<DelayTm>][,[<Ack>][,[
<errMode>][,]<HeaderType
>][,[[<AsyncMode>][,[<Tim
eoutVal>]]]]]]]]
OK
Execution Command
Responses
AT+CIPCCFG
Set default value:
OK
EN
TI
Write Command
O
N
FI
D
ERROR
C
Defined values
SI
M
C
O
M
<NmRetry>
a numeric parameter which is number of retransmission to be made for an IP packet.The default
value is 10.
<DelayTm>
a numeric parameter which is number of milliseconds to delay to output data of Receiving.The
default value is 0.
<Ack>
NOTE: This parameter is only used to be compatible with old TCP/IP command set.
<errMode>
a numeric parameter which sets mode of reporting error result code.
0 error result code with numeric values
1 error result code with string values
< HeaderType >
a numeric parameter that select which data header of receiving data, it only takes effect in
multi-client mode.
0 add data header, the format is “+IPD<data length>”
1 add data header, the format is “+RECEIVE,<link num>,<data length>”
SIM7500_SIM7600 Series_AT Command Manual_V1.07
284
2017-12-25
Smart Machine Smart Decision
E
< AsyncMode >
NOTE: This parameter is only used to be compatible with old TCP/IP command set.
< TimeoutVal >
a numeric parameter that set the minimum retransmission timeout value for TCP connection. The
unit is millisecond. The range is 500-120000.
FI
L
Examples
TI
AT+CIPSENDMODE Select sending mode
EN
15.2.2
AL
AT+CIPCCFG=?
+CIPCCFG: (0-10),(0-1000),(0),(0-1),(0-1) ,(0) ,(500-120000)
OK
AT+CIPCCFG=3,500,1,1,1,0,500
OK
Description
Syntax
Vendor
M
NO
References
C
SIM PIN
O
N
FI
D
This command is used to sending wait peer TCP ACK mode or sending without waiting peer TCP
ACK mode. The default mode is sending without waiting peer TCP ACK mode.
NOTE: Currently SIMCom 3G modules support both new TCP/IP command set and old TCP/IP
command set, the new TCP/IP command set support multiple TCP connections, and backward
compatible with the old command set. When the AT+NETOPEN command called with
parameters(like AT+NETOPEN=”TCP”) according to the old command set, the sending mode
configured by this command will be ignore, and the TCP data sending will wait for TCP ACK
always.
Responses
+CIPSENDMODE: (list of supported <mode>s)
OK
Read Command
AT+CIPSENDMODE?
Responses
+CIPSENDMODE: <mode>
SI
M
C
O
Test Command
AT+CIPSENDMODE=?
Write Command
AT+CIPSENDMODE=<
mode>
OK
Responses
OK
ERROR
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
285
2017-12-25
Smart Machine Smart Decision
<mode>
0 –
1 –
sending without waiting peer TCP ACK mode
sending wait peer TCP ACK mode
Examples
FI
L
AL
TI
AT+CIPTIMEOUT Set TCP/IP timeout value
EN
15.2.3
E
AT+CIPSENDMODE?
+CIPSENDMODE: 1
OK
AT+CIPSENDMODE=1
OK
AT+CIPSENDMODE=?
+CIPSENDMODE: (0,1)
OK
Description
SIM PIN
References
Vendor
N
NO
FI
D
This command is used to set timeout value for AT+NETOPEN/AT+CIPOPEN/AT+CIPSEND.
Test Command
AT+CIPTIMEOUT=?
C
O
Syntax
C
O
M
Read Command
AT+CIPTIMEOUT?
Responses
OK
Responses
+CIPTIMEOUT:
<cipsend_timeout>
Responses
AT+CIPTIMEOUT=[<n
etopen_timeout>][,
[<cipopen_timeout>][,
[<cipsend_timeout>]]]
OK
M
<cipopen_timeout>,
OK
Write Command
SI
<netopen_timeout>,
ERROR
Defined values
<netopen_timeout>
Timeout value for AT+NETOPEN, default value is 120000 milliseconds.The range of this value is
SIM7500_SIM7600 Series_AT Command Manual_V1.07
286
2017-12-25
Smart Machine Smart Decision
FI
L
E
from 3000ms to 120000ms.
<cipopen_timeout>
Timeout value for AT+CIPOPEN, default value is 120000 milliseconds. The range of this value is
from 3000ms to 120000ms.
<cipsend_timeout>
Timeout value for AT+CIPSEND, default value is 120000 milliseconds. The range of this value is
from 3000ms to 120000ms.
Examples
AL
AT+CIPTIMEOUT?
+CIPTIMEOUT: 30000,20000,40000
EN
AT+CIPHEAD Add an IP head when receiving data
D
15.2.4
TI
OK
AT+CIPTIMEOUT=30000,20000,40000
OK
FI
Description
SIM PIN
O
Vendor
C
YES
References
N
This command is used to add an IP head when receiving data.
Syntax
O
M
Test Command
AT+CIPHEAD=?
SI
M
C
Read Command
AT+CIPHEAD?
Responses
+CIPHEAD: (list of supported<mode>s)
OK
ERROR
Responses
+CIPHEAD: <mode>
OK
ERROR
Write Command
AT+CIPHEAD=<mode>
Responses
OK
Execution Command
ERROR
Responses
AT+CIPHEAD
Set default value:
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
287
2017-12-25
Smart Machine Smart Decision
Defined values
E
<mode>
a numeric parameter which indicates whether adding an IP header to received data or not
0 – not add IP header
1 – add IP header, the format is “+IPD(data length)”
FI
L
Examples
TI
AT+CIPSRIP Show Remote IP address and Port
EN
15.2.5
AL
AT+CIPHEAD=?
+CIPHEAD: (0-1)
OK
AT+CIPHEAD=0
OK
Description
SIM PIN
References
FI
Vendor
N
YES
D
This command is used to set whether display IP address and port of sender when receiving data.
Responses
+CIPSRIP: (list of supported <mode>s)
OK
C
Test Command
AT+CIPSRIP=?
O
Syntax
ERROR
C
O
M
Read Command
AT+CIPSRIP?
SI
M
Write Command
AT+CIPSRIP=<mode>
Execution Command
AT+CIPSRIP
Responses
+CIPSRIP: <mode>
OK
ERROR
Responses
OK
ERROR
Responses
Set default value:
OK
Defined values
<mode>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
288
2017-12-25
Smart Machine Smart Decision
E
a numeric parameter which indicates whether show the prompt of where the data received or not
before received data.
0 – do not show the prompt
1 – show the prompt,the format is as follows:
“RECV FROM:<IP ADDRESS>:<PORT>”
FI
L
Examples
TI
AT+CIPMODE Select TCP/IP application mode
EN
15.2.6
AL
AT+CIPSRIP=?
+CIPSRIP: (0-1)
OK
AT+CIPSRIP=1
OK
Description
Vendor
N
NO
References
FI
SIM PIN
D
This command is used to select transparent mode (data mode) or non-transparent mode (command
mode ).The default mode is non-transparent mode.
O
M
Read Command
AT+CIPMODE?
M
C
Write Command
AT+CIPMODE=<mode>
SI
Execution Command
AT+CIPMODE
Responses
+CIPMODE: (list of supported <mode>s)
OK
C
Test Command
AT+CIPMODE=?
O
Syntax
Responses
+CIPMODE: <mode>
OK
Responses
OK
ERROR
Responses
Set default value(<mode>=0):
OK
Defined values
<mode>
0 – Non transparent mode
SIM7500_SIM7600 Series_AT Command Manual_V1.07
289
2017-12-25
Smart Machine Smart Decision
1
– Transparent mode
Examples
FI
L
AL
Open socket
Description
TI
AT+NETOPEN
EN
15.2.7
E
AT+CIPMODE?
+CIPMODE: 1
OK
AT+CIPMODE=1
OK
AT+CIPMODE=?
+CIPMODE: (0-1)
OK
AT+CIPMODE
OK
SIM PIN
O
Vendor
C
YES
References
Syntax
M
C
O
M
Read Command
AT+NETOPEN?
Execution Command
AT+NETOPEN
SI
N
FI
D
This command opens packet network,
NOTE: The test command and the write command of AT+NETOPEN is reserved for being
compatible with old TCP/IP command set, and the old TCP/IP command set is not recommended to
be used any longer.
Responses
+NETOPEN:<net_state>
OK
ERROR
+IP ERROR: <err_info>
ERROR
+CME ERROR: <err>
Responses
OK
+NETOPEN: <err>
+NETOPEN: <err>
OK
+NETOPEN: <err>
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
290
2017-12-25
Smart Machine Smart Decision
+IP ERROR: <err_info>
ERROR
ERROR
FI
L
EN
Examples
N
FI
D
AT+NETOPEN
OK
+NETOPEN: 0
AT+NETOPEN?
+NETOPEN: 1, 1
OK
O
AT+NETCLOSE Close socket
C
15.2.8
AL
TI
<net_state>
a numeric parameter that indicates the state of PDP context activation:
0
network close (deactivated)
1
network open(activated)
<err >
The result of operation, 0 is success, other value is failure.
<err_info>
A string parameter that displays the cause of occurring error.
E
Defined values
Description
M
This command closes network. Before calling this command, all opened sockets must be closed
first.
References
O
SIM PIN
Vendor
C
YES
M
Syntax
SI
Test Command
AT+NETCLOSE=?
Responses
OK
ERROR
Execution Command
Responses
AT+NETCLOSE
OK
+NETCLOSE: <err>
+NETCLOSE: <err>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
291
2017-12-25
Smart Machine Smart Decision
OK
+NETCLOSE: <err>
ERROR
+IP ERROR: <error message>
E
ERROR
FI
L
ERROR
D
Examples
O
N
FI
AT+NETCLOSE
OK
+NETCLOSE: 0
AT+IPADDR Inquire socket PDP address
C
15.2.9
TI
EN
<err>
The result of operation, 0 is success, other value is failure.
<error message>
The list of all error message:
Invalid parameter
Operation not supported
No data
AL
Defined values
Description
M
This command inquires the IP address of current active socket PDP.
SIM PIN
Vendor
C
O
YES
References
M
Syntax
SI
Test Command
AT+IPADDR=?
Responses
OK
ERROR
Execution Command
Responses
AT+IPADDR
+IPADDR: < ip_address>
OK
+IP ERROR:<err_info>
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
292
2017-12-25
Smart Machine Smart Decision
ERROR
Examples
TI
AL
AT+IPADDR
+IPADDR: 10.71.155.118
OK
FI
L
<ip_address>
A string parameter that identifies the IP address of current active socket PDP.
<err_info>
A string parameter that displays the cause of occurring error.
E
Defined values
IP filter configuration
EN
15.2.10 AT+CIPFILTERSET
Description
Vendor
Syntax
Test Command
C
O
YES
References
N
SIM PIN
FI
D
This command is used to enable the IP filter feature in the multi-PDP mode. The IP filter is a
feature which to support embedded TCP/IP protocol applications while the mobile device is in a
PPP call.
O
M
AT+CIPFILTERSET=?
Responses
+CIPFILTERSET: (0-9),(0,1)
OK
ERROR
Responses
AT+CIPFILTERSET?
+CIPFILTERSET: <enabled_flag>
+CIPFILTERSET: 0,<enabled_flag>
+CIPFILTERSET: 1,<enabled_flag>
…
SI
M
C
Read Command
OK
Write Command
Responses
AT+CIPFILTERSET=<link_
num>,<enabled_flag>
OK
If ERROR occurred
SIM7500_SIM7600 Series_AT Command Manual_V1.07
293
2017-12-25
Smart Machine Smart Decision
Or
AT+CIPFILTERSET=<enab
led_flag>
+IP ERROR: <error message>
ERROR
E
Defined values
D
EN
TI
AL
FI
L
<link_num>
A numeric parameter that identifies a connection. The range of permitted values is 0 to 9. This
parameter is used for multi clients.
<enabled_flag>
A numeric flag parameter that show the <link_num> connection whether or not to use the IP
filter feature. The default value is 0.
0: disable the IP filter feature.
1: enable the IP filter feature.
NOTE:
1. The execution command must be executed before opening network.
2. If you want to use the PPP dial and socket data at the same time, set the IP filter flag
enabled. In this usage, the PPP dial operation must be executed before the socket command.
N
SI
M
C
O
M
C
OK
AT+CIPFILTERSET =0,1
OK
AT+CIPFILTERSET =1
OK
AT+CIPFILTERSET?
+CIPFILTERSET: 1
+CIPFILTERSET: 0,1
+CIPFILTERSET: 1,0
+CIPFILTERSET: 2,0
+CIPFILTERSET: 3,0
+CIPFILTERSET: 4,0
+CIPFILTERSET: 5,0
+CIPFILTERSET: 6,0
+CIPFILTERSET: 7,0
+CIPFILTERSET: 8,0
+CIPFILTERSET: 9,0
O
AT+CIPFILTERSET=?
+CIPFILTERSET: (0-9),(0,1)
FI
Examples
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
294
2017-12-25
Smart Machine Smart Decision
15.2.11 AT+SERVERSTART
Startup TCP server
Description
SIM PIN
References
Vendor
AL
YES
FI
L
E
This command starts up TCP server, and the server can receive the request of TCP client. After the
command executes successfully, an unsolicited result code is returned when a client tries to connect
with module and module accepts request. The unsolicited result code is +CLIENT: <
link_num >,<server_index>,<client_IP>:<port>.
Syntax
Responses
OK
TI
Test Command
AT+SERVERSTART=?
D
ERROR
EN
+SERVERSTART: (list of supported <port>), (list of supported <
server_index >)
OK
Responses
AT+SERVERSTART?
[+SERVERSTART: <server_index>,< port >
…]
OK
O
N
FI
Read Command
C
+CIPERROR: <err>
ERROR
ERROR
M
+IP ERROR: <error message>
ERROR
Responses
AT+SERVERSTART=<port
>,<server_index>[,<backlog
>]
OK
SI
M
C
O
Write Command
+CIPERROR: <err>
ERROR
ERROR
Defined values
<server_index>
The TCP server index(The range of permitted values is 0 to 3).
<backlog>
The maximum connections can be queued in listen queue. The range is from 1 to 3. Default is 3.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
295
2017-12-25
Smart Machine Smart Decision
FI
L
E
<err>
The result of operation, 0 is success, other value is failure.
<error message>
The list of all error message:
Invalid parameter
Operation not supported
No data
Examples
AL
AT+SERVERSTART?
+SERVERSTART: 0, 1000
+SERVERSTART: 2, 2000
15.2.12 AT+SERVERSTOP
EN
TI
OK
Stop TCP server
D
Description
Vendor
C
YES
References
O
SIM PIN
N
FI
This command stops TCP server. Before stopping a TCP server, all sockets with <server_index>
equals to the closing TCP server index must be closed first.
Responses
OK
ERROR
M
Test Command
AT+SERVERSTOP=?
O
Syntax
SI
M
C
Execution Command
AT+SERVERSTOP=<server
_index>
Responses
+SERVERSTOP: <server_index>,<err>
OK
OK
+SERVERSTOP: <server_index>,<err>
+SERVERSTOP: <server_index>,<err>
ERROR
ERROR
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
296
2017-12-25
Smart Machine Smart Decision
<server_index>
The TCP server index(The range of permitted values is 0 to 3).
<err>
The result of operation, 0 is success, other value is failure.
E
Examples
Establish connection in multi-socket mode
TI
15.2.13 AT+CIPOPEN
AL
FI
L
AT+SERVERSTOP=?
OK
AT+SERVERSTOP=0
+SERVERSTOP: 0,0
OK
EN
Description
This command is used to establish a connection with TCP server and UDP server, The sum of
all of connections is 10。
Vendor
FI
YES
References
D
SIM PIN
O
Responses
+CIPOPEN: (list of supported <link_num>s), (list of supported
<type>s)
OK
C
Test Command
AT+CIPOPEN=?
N
Syntax
M
ERROR
Responses
AT+CIPOPEN?
+CIPOPEN: <link_num> [,<type>,<serverIP>,<serverPort>,<index>]
+CIPOPEN: <link_num> [,<type>,<serverIP>,<serverPort>,<index>]
[…]
OK
SI
M
C
O
Read Command
ERROR
+IP ERROR: <error message>
ERROR
Write Command
Responses
AT+CIPOPEN=
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
297
2017-12-25
Smart Machine Smart Decision
<link_num>,”TCP”,<serve
rIP>,<serverPort>[,<localP
ort>]
+CIPOPEN: <link_num>,<err>
Open connection successfully in transparent mode:
CONNECT [<text>]
Open connection failed in transparent mode:
CONNECT FAIL
FI
L
E
+CIPOPEN: <link_num>,<err>
ERROR
ERROR
+CIPOPEN: <link_num>,<err>
OK(if udp open)
+CIPOPEN: <link_num>,<err>
ERROR
TI
ERROR
AL
AT+CIPOPEN=
<link_num>,”UDP”,,,<loc
alPort>
EN
Defined values
SI
M
C
O
M
C
O
N
FI
D
<link_num>
a numeric parameter that identifies a connection. The range of permitted values is 0 to 9. If
AT+CIPMODE=1 is set, the <link_num> is restricted to be only 0.
<type>
a string parameter that identifies the type of transmission protocol.
TCP Transfer Control Protocol
UDP User Datagram Protocol
If AT+CIPMODE=1 is set, the <type> is restricted to be only “TCP”.
<serverIP>
A string parameter that identifies the IP address of server.The IP address format consists of 4
octets,separated by decimal point:”AAA.BBB.CCC.DDD”. Also the domain name is supported
here. If the domain name is input here, the timeout value for the AT+CIPOPEN shall be decided by
AT+CIPDNSSET.
<serverPort>
a numeric parameter that identifies the port of TCP server, the range of permitted values is 0 to
65535.
NOTE: When open port as TCP, the port must be the opened TCP port;
When open port as UDP, the port may be any port.
But, for Qualcomm, connecting the port 0 is as an invalid operation.
<localPort>
a numeric parameter that identifies the port of local socket, the range of permitted values is 0 to
65535.
<index>
a numeric parameter that identifies the server index that the client linked when as a TCP server.
-1 Not as a TCP server
0-3 TCP server index
SIM7500_SIM7600 Series_AT Command Manual_V1.07
298
2017-12-25
FI
L
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
The result of operation, 0 is success, other value is failure.
<error message>
The list of all error message:
Invalid parameter
Operation not supported
No data
E
Smart Machine Smart Decision
C
TI
EN
O
M
C
O
N
FI
D
AT+CIPOPEN=0,”TCP”,”116.228.221.51”,100
OK
+CIPOPEN: 0,0
AT+CIPOPEN=1,”UDP”,,,8080
+CIPOPEN: 0,0
OK
AT+CIPOPEN=?
+CIPOPEN: (0-9), (“TCP”, “UDP”)
OK
AT+CIPOPEN?
+CIPOPEN: 0, “TCP”, “116.228.221.51”, 100, -1
+CIPOPEN: 1
+CIPOPEN: 2
+CIPOPEN: 3
+CIPOPEN: 4
+CIPOPEN: 5
+CIPOPEN: 6
+CIPOPEN: 7
+CIPOPEN: 8
+CIPOPEN: 9
OK
AL
Examples
Send data through TCP or UDP connection
SI
M
15.2.14 AT+CIPSEND
Description
This command is used to send data to remote side. The <length> field can be empty, when it is
empty, Each <Ctrl+Z> character present in the data should be coded as <ETX><Ctrl+Z>. Each
<ESC> character present in the data should be coded as <ETX><ESC>. Each <ETX> character will
be coded as <ETX><ETX>. Single <Ctrl+Z> means end of the input data. Single <ESC> is used to
cancel the sending.
<ETX> is 0x03, and <Ctrl+Z> is 0x1A, <ESC> is 0x1B.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
299
2017-12-25
Smart Machine Smart Decision
SIM PIN
YES
References
Vendor
Syntax
Responses
+CIPSEND: (list of supported <link_num>s), (list of supported <
length >s)
OK
FI
L
E
Test Command
AT+CIPSEND=?
+CIPERROR: <err>
AL
ERROR
ERROR
Responses
OK
TI
Read Command
AT+CIPSEND?
D
Responses
OK
+CIPSEND: <link_num>,<reqSendLength>, <cnfSendLength>
FI
+CIPERROR: <err>
ERROR
N
ERROR
C
O
Write Command
AT+CIPSEND=<link_num>,
[<length>]<CR>data
for
send
(If the <length> field is
empty, the <ctrl+z> needs to
be entered after all data is
input. <ESC> is use to
cancel the sending.)
EN
ERROR
M
(This format is for TCP
connect)
If sending successfully(udp sending):
OK
+CIPSEND: <link_num>, <reqSendLength>, <cnfSendLength>
+CIPERROR: <err>
ERROR
ERROR
SI
M
C
O
AT+CIPSEND=<link_num>,
[<length>],<serverIP>,<serv
erPort><CR>data for send
(If the <length> field is
empty, the <ctrl+z> needs to
be entered after all data is
input. <ESC> is use to
cancel the sending.)
(This format is for UDP
connect)
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
300
2017-12-25
Smart Machine Smart Decision
D
EN
TI
AL
FI
L
E
<link_num>
a numeric parameter that identifies a connection. The range of permitted values is 0 to 9.
<length>
a numeric parameter which indicates the length of sending data, it must be between1 and 1500.
<serverIP>
A string parameter that identifies the IP address of server.The IP address format consists of 4
octets,separated by decimal point:”AAA.BBB.CCC.DDD”.
<serverPort>
a numeric parameter that identifies the port of TCP server, the range of permitted values is 0 to
65535.
NOTE: When open port as TCP, the port must be the opened TCP port;
When open port as UDP, the port may be any port.
But, for Qualcomm, connecting the port 0 is as an invalid operation.
<reqSendLength>
a numeric parameter that requested number of data bytes to be transmitted.
<cnfSendLength>
a numeric parameter that confirmed number of data bytes to be transmitted.
-1
the connection is disconnected.
0
own send buffer or other side’s congestion window are full.
Examples
M
AT+CIPSEND=0,1
>S
OK
C
O
N
FI
Note: If the <cnfSendLength> is not equal to the <reqSendLength>, the socket then cannot be used
further.
<err_info>
A string parameter that displays the cause of occurring error.
M
C
O
+CIPSEND: 0, 1, 1
AT+CIPSEND=1,1,”116.236.221.75”,6775
>S
OK
SI
+CIPSEND: 1, 1, 1
AT+CIPSEND=2,
>Hello<Ctrl+Z>
OK
+CIPSEND: 2,5,5
AT+CIPSEND=3,,”116.236.221.75”,6775
SIM7500_SIM7600 Series_AT Command Manual_V1.07
301
2017-12-25
Smart Machine Smart Decision
>Hello World<Ctrl+Z>
OK
AL
FI
L
E
+CIPSEND: 2,11,11
AT+CIPSEND=2,
>Hello<ESC>
ERROR
AT+CIPSEND=?
+CIPSEND: (0-9), (1-1500)
OK
Get the network data manually
Description
SIM PIN
References
Vendor
D
YES
EN
This command is used to get the network data manually.
TI
15.2.15 AT+CIPRXGET
FI
Syntax
Responses
+CIPRXGET: (0-4),(0-9),(1-1500)
OK
O
N
Test Command
AT+CIPRXGET=?
O
M
Read Command
AT+CIPRXGET?
C
ERROR
SI
M
C
Execution Command
(AT+CIPRXGET=1):
AT+CIPRXGET=<mode>,<
cid>[,<len>]
Responses
+CIPRXGET: <mode>
OK
ERROR
Responses
1. If <mode> = 0 or 1:
OK
2. If <mode> = 2 or 3:
+CIPRXGET: <mode>,<cid>,<read_len>,<rest_len>
<data>
OK
3. If<mode> = 4:
+CIPRXGET: 4,<cid>,<rest_len>
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
302
2017-12-25
Smart Machine Smart Decision
If ERROR occurred
ERROR
+IP ERROR: <error message>
E
ERROR
FI
L
Defined values
M
C
O
M
C
O
N
FI
D
EN
TI
AL
<mode>
0 – set the way to get the network data automatically
1 – set the way to get the network data manually
2 – read data, the max read length is 1500
3 – read data in HEX form, the max read length is 750
4 – get the rest data length
<cid>
A numeric parameter that identifies a connection. The range of permitted values is 0 to 9.
<len>
The data length to be read.
Not required, the default value is 1500 when <mode>=2, and 750 when <mode>=3.
<read_len>
The length of the data that have read.
<rest_len>
The data length which not read in the buffer.
< data >
The read data.
<error message>
The list of all error message:
Invalid parameter
Operation not supported
No data
NOTE:
1. When <mode> is set to 1 and the 2-4 mode will take effect.
2. If AT+CIPRXGET=1, it will report +CIPRXGET: 1,<cid>(multi client) when
received data and the buffer is empty.
SI
Examples
AT+CIPRXGET=?
+CIPRXGET: (0-4),(1-1500)
OK
AT+CIPRXGET?
+CIPRXGET: 1
SIM7500_SIM7600 Series_AT Command Manual_V1.07
303
2017-12-25
Smart Machine Smart Decision
FI
L
E
OK
AT+CIPRXGET=1
OK
AT+CIPRXGET=2,100
+CIPRXGET: 2,100,1300
01234567890123456789012345678901234567890123456789012345678901234567890123456789
01234567890123456789
EN
TI
AL
OK
AT+CIPRXGET=3,100
+CIPRXGET: 3,100,1200
30313233343536373839303132333435363738393031323334353637383930313233343536373839
30313233343536373839303132333435363738393031323334353637383930313233343536373839
3031323334353637383930313233343536373839
D
OK
AT+CIPRXGET=4
+CIPRXGET: 4,1200
C
O
N
FI
OK
AT+CIPRXGET=2,0,100
+CIPRXGET: 2,0,100,1300
01234567890123456789012345678901234567890123456789012345678901234567890123456789
01234567890123456789
C
O
M
OK
AT+CIPRXGET=3,0,100
+CIPRXGET: 3,0,100,1200
30313233343536373839303132333435363738393031323334353637383930313233343536373839
30313233343536373839303132333435363738393031323334353637383930313233343536373839
3031323334353637383930313233343536373839
SI
M
OK
AT+CIPRXGET=4,0
+CIPRXGET: 4,0,1200
OK
15.2.16 AT+CIPCLOSE
Close TCP or UDP socket
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
304
2017-12-25
Smart Machine Smart Decision
This command is used to close TCP or UDP socket.
SIM PIN
YES
References
Vendor
E
Syntax
Responses
+CIPCLOSE: (list of supported <link_num>s)
OK
ERROR
Read Command
AT+CIPCLOSE?
Responses
+CIPCLOSE:<link0_state>,<link1_state>,<link2_state>,
<link3_state>,<link4_state>,<link5_state>,<link6_state>,
<link7_state>,<link8_state>,<link9_state>
OK
EN
TI
AL
FI
L
Test Command
AT+CIPCLOSE=?
ERROR
Responses
OK
+CIPCLOSE: <link_num>,<err>
N
FI
Write Command
AT+CIPCLOSE=
<link_num>
D
+CIPCLOSE: <link_num>,<err>
ERROR
O
+CIPCLOSE: <link_num>,<err>
OK
C
+CIPCLOSE: <link_num>,<err>
ERROR
M
ERROR
O
Defined values
SI
M
C
<link_num>
a numeric parameter that identifies a connection. The range of permitted values is 0 to 9.
<linkx_state>
a numeric parameter that identifies state of <link_num>. the range of permitted values is 0 to 1.
0 disconnected
1 connected
<err_info>
A string parameter that displays the cause of occurring error.
Examples
AT+CIPCLOSE?
+CIPCLOSE: 1, 0, 0, 0, 0, 0, 0, 0, 0, 0
SIM7500_SIM7600 Series_AT Command Manual_V1.07
305
2017-12-25
Smart Machine Smart Decision
15.2.17 AT+CIPSTAT
FI
L
E
OK
AT+CIPCLOSE=?
+CIPCLOSE: (0-9)
OK
AT+CIPCLOSE=0
OK
+CIPCLOSE: 0,0
Inquire the total size of data sent or received
AL
Description
SIM PIN
References
Vendor
EN
YES
TI
This command is used to inquire the total size of data sent or received for a socket in multiple
socket modes (Only valid for client TCP socket mode).
D
Syntax
Responses
+CIPSTAT: (list of supported <link_num>s)
OK
Write Command
Responses
AT+CIPSTAT=<link_num>
+CIPSTAT: <sent_size>, <recv_size>
OK
C
O
N
FI
Test Command
AT+CIPSTAT=?
+IP ERROR: <err_info>
ERROR
M
Defined values
SI
M
C
O
< link_num>
a numeric parameter that identifies a connection. The range of permitted values is 0 to 9.
<sent_size>
Total size of sent data.
<recv_size>
Total size of received data.
<err_info>
A string parameter that displays the cause of occurring error.
Examples
AT+CIPSTAT=0
+CIPSTAT: 10, 20
SIM7500_SIM7600 Series_AT Command Manual_V1.07
306
2017-12-25
Smart Machine Smart Decision
OK
AT+CIPSTAT=?
+CIPSTAT: (0-9)
OK
The following table lists information elements which may be reported.
Information
Description
Network is closed for network error(Out
of service, etc). When this event happens,
user’s application needs to check and
close all opened sockets, and then uses
AT+NETCLOSE to release the network
library if AT+NETOPEN? shows the
network library is still opened.
AL
CLOSED
EN
TI
+CIPEVENT:
NETWORK
UNEXPECTEDLY
FI
L
E
15.2.18 Information elements related to TCP/IP
Socket is closed passively.
<client_index> is the link number.
<close_reason>:
0 - Closed by local, active
1 - Closed by remote, passive
2 - Closed for sending timeout
N
FI
D
+IPCLOSE: <client_index>, <close_reason>
TCP server accepted a new socket client,
the index is <link_num>, the TCP server
index is <server_index>. The peer IP
address is <client_IP>, the peer port is
<port>.
M
C
O
+CLIENT:
<
link_num >,<server_index>,<client_IP>:<port>
M
C
0
1
2
O
15.2.19 Unsolicited TCP/IP command <err> Codes
SI
3
4
5
6
7
8
9
operation succeeded
Network failure
Network not opened
Wrong parameter
Operation not supported
Failed to create socket
Failed to bind socket
TCP server is already listening
Busy
Sockets opened
SIM7500_SIM7600 Series_AT Command Manual_V1.07
307
2017-12-25
Smart Machine Smart Decision
10
11
255
15.3.1
E
FTP
FI
L
15.3
Timeout
DNS parse failed for AT+CIPOPEN
Unknown error
AT+CFTPPORT Set FTP server port
Description
SIM PIN
References
TI
Vendor
EN
YES
AL
This command is used to set FTP server port.
Syntax
Responses
+CFTPPORT: (list of supported <port>s)
OK
Responses
+CFTPPORT: <port>
OK
Responses
OK
C
Write Command
AT+CFTPPORT=<port>
O
Read Command
AT+CFTPPORT?
N
FI
D
Test Command
AT+CFTPPORT=?
+CME ERROR
M
Defined values
C
O
<port>
The FTP server port, from 1 to 65535, and default value is 21.
M
Examples
SI
AT+CFTPPORT=21
OK
AT+CFTPPORT?
+CFTPPORT:21
OK
AT+CFTPPORT=?
+CFTPPORT: (1-65535)
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
308
2017-12-25
Smart Machine Smart Decision
15.3.2
AT+CFTPMODE
Set FTP mode
Description
This command is used to set FTP passive/proactive mode. Default is passive mode.
Vendor
FI
L
YES
References
E
SIM PIN
Syntax
Responses
+CFTPMODE: (list of supported <mode>s)
OK
Responses
+CFTPMODE: <mode>
OK
Responses
OK
AL
Test Command
AT+CFTPMODE=?
Write Command
AT+CFTPMODE=<mode>
FI
D
+CME ERROR
EN
TI
Read Command
AT+CFTPMODE?
O
C
<mode>
The FTP access mode:
0 – proactive mode.
1 – passive mode.
N
Defined values
M
Examples
SI
M
C
O
AT+CFTPMODE=1
OK
AT+CFTPMODE?
+CFTPMODE: 1
OK
AT+CFTPMODE=?
+CFTPMODE: (0,1)
OK
15.3.3
AT+CFTPTYPE
Set FTP type
Description
This command is used to set FTP type. Default is binary type.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
309
2017-12-25
Smart Machine Smart Decision
SIM PIN
YES
References
Vendor
Write Command
AT+CFTPTYPE=<type>
EN
FI
N
O
C
C
O
M
AT+CFTPTYPE=A
OK
AT+CFTPTYPE?
+CFTPTYPE: A
OK
AT+CFTPTYPE=?
+CFTPTYPE: (A,I)
OK
D
<type>
The FTP type:
I – binary type.
A – ASCII type.
Examples
TI
+CME ERROR
Defined values
FI
L
Read Command
AT+CFTPTYPE?
Responses
+CFTPTYPE: (list of supported <type>s)
OK
Responses
+CFTPTYPE: <type>
OK
Responses
OK
AL
Test Command
AT+CFTPTYPE=?
E
Syntax
AT+CFTPSERV Set FTP server domain name or IP address
M
15.3.4
SI
Description
This command is used to set FTP server domain name or IP address.
SIM PIN
YES
References
Vendor
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
310
2017-12-25
Smart Machine Smart Decision
Read Command
AT+CFTPSERV?
Write Command
AT+CFTPSERV=
”<address>”
E
Responses
+CFTPSERV: “ADDRESS”
OK
Responses
+CFTPSERV: ”<address>”
OK
Responses
OK
FI
L
Test Command
AT+CFTPSERV=?
+CME ERROR
AL
Defined values
TI
<address>
The FTP server domain name or IP address. The maximum length is 100.
D
C
O
N
FI
AT+CFTPSERV=”www.mydomain.com”
OK
AT+CFTPSERV?
+CFTPSERV: “www.mydomain.com”
OK
AT+CFTPSERV=?
+CFTPSERV: ”ADDRESS”
OK
AT+CFTPSERV=”10.0.0.127”
OK
EN
Examples
AT+CFTPUN
M
15.3.5
Set user name for FTP access
O
Description
C
This command is used to set user name for FTP server access.
SIM PIN
Vendor
SI
M
YES
References
Syntax
Test Command
AT+CFTPUN=?
Read Command
AT+CFTPUN?
Responses
+CFTPUN: “NAME”
OK
Responses
+CFTPUN: “<name>”
SIM7500_SIM7600 Series_AT Command Manual_V1.07
311
2017-12-25
Smart Machine Smart Decision
OK
Responses
OK
Write Command
AT+CFTPUN=“<name>”
+CME ERROR
E
Defined values
AL
Examples
N
FI
D
EN
TI
AT+CFTPUN=”myname”
OK
AT+CFTPUN=”anonymous”
OK
AT+CFTPUN?
+CFTPUN: “myname”
OK
AT+CFTPUN=?
+CFTPUN: ”NAME”
OK
AT+CFTPPW Set user password for FTP access
O
15.3.6
FI
L
<name>
The user name for FTP server access. The maximum length is 30.
C
Description
This command is used to set user password for FTP server access.
Vendor
O
YES
References
M
SIM PIN
C
Syntax
M
Test Command
AT+CFTPPW=?
SI
Read Command
AT+CFTPPW?
Write Command
AT+CFTPPW=“<password>
”
Responses
+CFTPPW: “PASSWORD”
OK
Responses
+CFTPPW: “<password>”
OK
Responses
OK
+CME ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
312
2017-12-25
Smart Machine Smart Decision
Defined values
<password>
The user password for FTP server access. The maximum length is 40.
E
Examples
AL
TI
AT+CFTPGETFILE
Get a file from FTP server to EFS
EN
15.3.7
FI
L
AT+CFTPPW=”mypass”
OK
AT+CFTPPW?
+CFTPPW: “mypass”
OK
AT+CFTPPW=?
+CFTPPW: ”mypass”
OK
Description
Vendor
Syntax
Responses
+CFTPGETFILE: [{non-ascii}]“FILEPATH”, (list of supported
<dir>s) [, (list of supported <rest_size>s)]
OK
Responses
OK
+CFTPGETFILE: 0
M
C
Test Command
AT+CFTPGETFILE=?
O
N
YES
References
FI
SIM PIN
D
This command is used to download a file from FTP server to module EFS.
+CME ERROR
OK
+CFTPGETFILE: <err>
SI
M
C
O
Write Command
AT+CFTPGETFILE=
“<filepath>”,<dir>[,<rest_siz
e>]
Defined values
<filepath>
The remote file path. When the file path doesn’t contain ”/”, this command transfers file from the
current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter
should contain a prefix of {non-ascii}.
<dir>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
313
2017-12-25
Smart Machine Smart Decision
FI
L
E
The directory to save the downloaded file:
0 – current directory [refer to AT+FSCD]
<rest_size>
The value for FTP “REST” command which is used for broken transfer when transferring failed last
time. The range is from 0 to 2147483647.
<err>
The error code of FTP operation.
AT+CFTPPUTFILE
TI
Upload a file from module EFS to FTP server
O
15.3.8
N
FI
D
EN
AT+CFTPGETFILE=”/pub/mydir/test1.txt”,0
OK
…
+CFTPGETFILE: 0
AT+CFTPGETFILE=” test2.txt”,0
OK
…
+CFTPGETFILE: 0
AT+CFTPGETFILE={non-ascii}” B2E2CAD42E747874”,0
OK
…
+CFTPGETFILE: 0
AL
Examples
C
Description
This command is used to upload a file from the module EFS to FTP server.
Vendor
O
YES
References
M
SIM PIN
C
Syntax
SI
M
Test Command
AT+CFTPPUTFILE=?
Write Command
AT+CFTPPUTFILE=“<filep
ath>”,<dir>[,<rest_size>]
Responses
+CFTPPUTFILE: [{non-ascii}] “FILEPATH”, (list of supported
<dir>s)[, (list of supported <rest_size>s)]
OK
Responses
OK
+CFTPPUTFILE: 0
+CME ERROR
OK
+CFTPPUTFILE: <err>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
314
2017-12-25
Smart Machine Smart Decision
Defined values
TI
AL
FI
L
E
<filepath>
The remote file path. When the file path doesn’t contain “/”, this command transfers file to the
current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter
should contain a prefix of {non-ascii}.
<dir>
The directory that contains the file to be uploaded:
0 – current directory [refer to AT+FSCD]
<rest_size>
The value for FTP “REST” command which is used for broken transfer when transferring failed last
time. The range is from 0 to 2147483647.
<err>
The error code of FTP operation.
EN
Examples
C
O
N
FI
D
AT+CFTPPUTFILE=”/pub/mydir/test1.txt”,0, 10
OK
+CFTPPUTFILE: 0
AT+CFTPPUTFILE=” test2.txt”,0
OK
…
+CFTPPUTFILE: 0
AT+CFTPPUTFILE={non-ascii}” B2E2CAD42E747874”,0
OK
…
+CFTPPUTFILE: 0
AT+CFTPGET Get a file from FTP server and output it to SIO
M
15.3.9
O
Description
M
C
This command is used to get a file from FTP server and output it to serial port. This command
may have a lot of DATA transferred to DTE using serial port, The AT+CATR command is
recommended to be used.
SI
SIM PIN
YES
References
Vendor
Syntax
Test Command
AT+CFTPGET=?
Responses
+CFTPGET: [{non-ascii}]“FILEPATH”[,(list of
<rest_size>s)] [,(list of supported <using_cache>s)]
SIM7500_SIM7600 Series_AT Command Manual_V1.07
315
supported
2017-12-25
Smart Machine Smart Decision
E
FI
L
D
EN
AT+CFTPCACHERD?
+CFTPCACHERD: 102400
OK
AL
If the <using_cache> is 1:
OK
+CFTP: RECV EVENT
TI
Write Command
AT+CFTPGET=“<filepath>
”[,<rest_size>[,<using_cache
>]]
OK
Responses
If the <using_cache> is 0 (default):
OK
+CFTPGET: DATA,<len>
…
+CFTPGET: DATA, <len>
…
…
+CFTPGET: 0
O
N
FI
//output cached data now:
AT+CFTPCACHERD
+CFTPGET: DATA,<len>
…
OK
C
......
SI
M
C
O
M
+CFTPGET: 0
+CFTPGET: <err>
ERROR
ERROR
OK
[+CFTPGET: DATA, <len>
…
+CFTPGET: DATA, <len>
…
…]
+CFTPGET: <err>
Defined values
<filepath>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
316
2017-12-25
Smart Machine Smart Decision
TI
AL
FI
L
E
The remote file path. When the file path doesn’t contain ”/”, this command transfer file from the
current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter
should contain a prefix of {non-ascii}.
<rest_size>
The value for FTP “REST” command which is used for broken transfer when transferring failed last
time. The range is from 0 to 2147483647.
<len>
The length of FTP data contained in this packet.
<err>
The error code of FTP operation.
<using_cache>
0 – Do not use cache
1 – Use cache(Data will be output using AT+CFTPCACHERD command)
Examples
C
O
M
C
O
N
FI
D
EN
AT+CFTPGET=”/pub/mydir/test1.txt”, 10
OK
+CFTPGET: DATA, 1020,
…
+CFTPGET: DATA, 1058,
…
…
+CFTPGET: 0
AT+CFTPGET={non-ascii}”/2F74657374646972/B2E2CAD42E747874”
OK
+CFTPGET: DATA, 1020,
…
+CFTPGET: 0
AT+CFTPGET=?
+CFTPGET: [{non-ascii}]“FILEPATH” [,(0-2147483647)]
OK
M
15.3.10 AT+CFTPPUT Upload the DATA from SIO to FTP server
SI
Description
This command is used to upload the DATA from serial port to FTP server as a file . Each <Ctrl+Z>
character present in the data flow of serial port when downloading FTP data will be coded as
<ETX><Ctrl+Z>. Each <ETX> character will be coded as <ETX><ETX>. Single <Ctrl+Z> means
end of the FTP data.
<ETX> is 0x03, and <Ctrl+Z> is 0x1A.
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
317
2017-12-25
Smart Machine Smart Decision
YES
Vendor
Syntax
Responses
+CFTPPUT: [{non-ascii}] “FILEPATH” [, (list of supported
<rest_size>s)]
OK
Responses
+CFTPPUT: BEGIN
OK
AL
Execution Command
AT+CFTPPUT=“<filepath>”
[,<rest_size>]
FI
L
E
Test Command
AT+CFTPPUT=?
EN
[+CFTPPUT: BEGIN]
+CFTPPUT: <err_code>
ERROR
TI
+CME ERROR
Defined values
Examples
M
C
O
N
FI
D
<filepath>
The remote file path. When the file path doesn’t contain “/”, this command transfers file to the
current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter
should contain a prefix of {non-ascii}.
<rest_size>
The value for FTP “REST” command which is used for broken transfer when transferring failed last
time. The range is from 0 to 2147483647.
<err_code>
Refer to “Unsolicited FTP Codes”.
SI
M
C
O
AT+CFTPPUT=”/pub/mydir/test1.txt”, 20
+CFTPPUT: BEGIN
…..<Ctrl+Z>
OK
AT+CFTPPUT={non-ascii}”/2F74657374646972/B2E2CAD42E747874”
+CFTPPUT: BEGIN
…..<Ctrl+Z>
OK
AT+CFTPPUT=?
+CFTPPUT: [{non-ascii}]“FILEPATH” [,(0-2147483647)]
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
318
2017-12-25
Smart Machine Smart Decision
15.3.11 AT+CFTPLIST List the items in the directory on FTP server
Description
This command is used to list the items in the specified directory on FTP server
Vendor
Syntax
Responses
+CFTPLIST: [{non-ascii}]“FILEPATH”[,(list
<using_cache>s)]
OK
Responses
If the <using_cache> is 0 (default):
AL
Test Command
AT+CFTPLIST=?
FI
L
YES
References
E
SIM PIN
TI
supported
EN
Write Command
AT+CFTPLIST=”<dir>”[,<u
sing_cache>]
of
N
FI
D
OK
+CFTPLIST: DATA,<len>
…
+CFTPLIST:<err>
O
If the <using_cache> is 1:
OK
SI
M
C
O
M
C
+CFTP: RECV EVENT
AT+CFTPCACHERD?
+CFTPCACHERD: 102400
OK
//output cached data now
AT+CFTPCACHERD
+CFTPLIST: DATA,<len>
…
OK
......
+CFTPLIST: <err>
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
319
2017-12-25
Smart Machine Smart Decision
Defined values
AL
FI
L
E
<dir>
The directory to be listed. If the directory contains non-ASCII characters, the <dir> parameter
should contain a prefix of {non-ascii}.
<len>
The length of data reported
<err>
The result code of the listing
<using_cache>
0 – Do not use cache
1 – Use cache(Data will be output using AT+CFTPCACHERD command)
TI
Examples
EN
AT+CFTPLIST=”/testd”
OK
+CFTPLIST: DATA,193
drw-rw-rw- 1 user
group
drw-rw-rw- 1 user
group
-rw-rw-rw- 1 user
group
FI
D
0 Sep 1 18:01 .
0 Sep 1 18:01 ..
2017 Sep 1 17:24 19800106_000128.jpg
Create a new directory on FTP server
O
15.3.12 AT+CFTPMKD
N
+CFTPLIST: 0
C
Description
Vendor
O
YES
M
This command is used to create a new directory on the FTP server. The maximum length of the
full path name is 256.
SIM PIN References
C
Syntax
SI
M
Test Command
AT+CFTPMKD=?
Write Command
AT+CFTPMKD=”<dir>”
Responses
+CFTPMKD: [{non-ascii}]”DIR”
OK
Responses
OK
+CFTPMKD:<err>
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
320
2017-12-25
Smart Machine Smart Decision
Defined values
FI
L
E
<dir>
The directory to be created. If the directory contains non-ASCII characters, the <dir> parameter
should contain a prefix of {non-ascii}.
<err>
The result code of the command
Examples
TI
AL
AT+CFTPMKD=”/testdir”
OK
AT+CFTPMKD={non-ascii}”74657374646972”
OK
EN
15.3.13 AT+CFTPRMD Delete a directory on FTP server
Description
SIM PIN
References
FI
Vendor
N
YES
D
This command is used to delete a directory on FTP server
O
M
Write Command
AT+CFTPRMD=”<dir>”
C
Responses
+CFTPRMD: [{non-ascii}]”DIR”
OK
Responses
OK
C
Test Command
AT+CFTPRMD=?
O
Syntax
+CFTPRMD:<err>
ERROR
M
Defined values
SI
<dir>
The directory to be removed. If the directory contains non-ASCII characters, the <dir> parameter
should contain a prefix of {non-ascii}.
<err>
The result code of the command
Examples
SIM7500_SIM7600 Series_AT Command Manual_V1.07
321
2017-12-25
Smart Machine Smart Decision
AT+CFTPRMD=”/testdir”
OK
AT+CFTPRMD={non-ascii}”74657374646972”
OK
Delete a file on FTP server
E
15.3.14 AT+CFTPDELE
FI
L
Description
This command is used to delete a file on FTP server
SIM PIN
Vendor
AL
YES
References
TI
Syntax
EN
D
+CFTPDELE:<err>
N
Write Command
AT+CFTPDELE=”<filenam
e>”
Responses
+CFTPDELE: [{non-ascii}]”FILENAME”
OK
Responses
OK
FI
Test Command
AT+CFTPDELE=?
C
Defined values
O
ERROR
O
M
<filename>
The name of the file to be deleted. If the file name contains non-ASCII characters, the <filename>
parameter should contain a prefix of {non-ascii}.
<err>
The result code of the command
C
Examples
SI
M
AT+CFTPDELE=”test”
OK
AT+CFTPDELE={non-ascii}”74657374”
OK
15.3.15 AT+CFTPCACHERD
Output cached data to MCU
Description
SIM7500_SIM7600 Series_AT Command Manual_V1.07
322
2017-12-25
Smart Machine Smart Decision
This command is used to output cached data (generated by AT+CFTPGET/AT+CFTPLIST) to
MCU.
SIM PIN
Vendor
Syntax
EN
TI
Execute Command
AT+CFTPCACHERD
Responses
+CFTPCACHERD: <len>
OK
Responses
If cache data is AT+CFTPGET:
[+CFTPGET: DATA,<out_len><CR><LF>]
[…]
OK
AL
Read Command
AT+CFTPCACHERD?
FI
L
E
YES
References
FI
D
If the cache data is AT+CFTPLIST:
[+CFTPLIST: DATA,<out_len><CR><LF>]
[…]
OK
O
N
ERROR
Defined values
O
Examples
M
C
<len>
The bytes of data cached in FTP module.
<out_len>
The bytes of data to output. The maximum value is 1024 for each AT+CFTPCACHERD calling.
SI
M
C
AT+CFTPCACHERD?
+CFTPCACHERD: 102400
OK
AT+CFTPCACHERD
+CFTPGET: DATA, 1024
…
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
323
2017-12-25
Smart Machine Smart Decision
FI
L
TI
EN
D
FI
N
O
FTPS
C
15.4
Description
Unknown error for FTP
FTP task is busy
Failed to resolve server address
FTP timeout
Failed to read file
Failed to write file
Not allowed in current state
Failed to login
Failed to logout
Failed to transfer data
FTP command rejected by server
Memory error
Invalid parameter
Network error
Failed to connect socket
Failed to send data using socket
Failed to receive data using socket
Failed to verify user name and password
Socket connect timeout
AL
Code of <err>
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
E
15.3.16 Unsolicited FTP Codes (Summary of CME ERROR Codes)
AT+CFTPSSTART Acquire FTPS protocol stack
O
15.4.1
M
These AT Command of FTPS related need the AT+CATR command to be set with the used port.
AT+CATR=0 may cause some problem.
C
Description
M
This command is used to acquire FTPS protocol stack.
SI
SIM PIN
YES
References
Vendor
Syntax
Execute Command
Responses
AT+CFTPSSTART
OK
+CFTPSSTART: <err>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
324
2017-12-25
Smart Machine Smart Decision
+CFTPSSTART: <err>
OK
ERROR
E
Defined values
FI
L
<err>
The result code of the acquiring FTP/FTPS stack. 0 is success. Other values are failure.
Examples
TI
AT+CFTPSSTOP Stop FTPS protocol stack
EN
15.4.2
AL
AT+CFTPSSTART
OK
+CFTPSSTART: 0
Description
Vendor
N
YES
FI
D
This command is used to stop FTPS protocol stack. Currently only explicit FTPS mode is
supported.
SIM PIN References
OK
+CFTPSSTOP: <err>
+CFTPSSTOP: <err>
OK
ERROR
C
O
M
AT+CFTPSSTOP
Responses
C
Execute Command
O
Syntax
M
Defined values
SI
<err>
The result code of the stopping FTP/FTPS stack. 0 is success. Other values are failure.
Examples
AT+CFTPSSTOP
OK
+CFTPSSTOP: 0
SIM7500_SIM7600 Series_AT Command Manual_V1.07
325
2017-12-25
Smart Machine Smart Decision
15.4.3
AT+CFTPSLOGIN
Login the FTPS server
Description
Vendor
FI
L
YES
E
This command is used to login the FTPS server. Each time, AT+CFTPSSTART command must
be executed before executing AT+CFTPSLOGIN command.
SIM PIN References
Responses
AT+CFTPSLOGIN=”<host>
”,<port>,”<username>”, ”<p
assword>”[<server_type>]
OK
+CFTPSLOGIN: <err>
EN
+CFTPSLOGIN: <err>
OK
TI
Write Command
AL
Syntax
D
ERROR
Defined values
SI
M
C
O
M
C
O
N
FI
<host>
The host address, maximum length is 256
<port>
The host listening port for SSL, the range is from 1 to 65535
<username>
The user name, maximum length is 256
<password>
The user password, maximum length is 256
<server_type>
The type of server:
0 – FTP server.
1 – Explicit FTPS server with AUTH SSL.
2 – Explicit FTPS server with AUTH TLS.
3 – Implicit FTPS server.
<err>
The result code of the FTP/FTPS login. 0 is success. Other values are failure.
Examples
AT+CFTPSLOGIN=”www.myftpsserver.com”,990, ”myname”, ”mypassword”,3
OK
+CFTPSLOGIN: 0
SIM7500_SIM7600 Series_AT Command Manual_V1.07
326
2017-12-25
Smart Machine Smart Decision
15.4.4
AT+CFTPSLOGOUT Logout the FTPS server
Description
E
This command is used to logout the FTPS server.
Responses
AT+CFTPSLOGOUT
OK
+CFTPSLOGOUT: <err>
AL
Execute Command
FI
L
Syntax
+CFTPSLOGOUT: <err>
OK
TI
ERROR
EN
Defined values
D
<err>
The result code of FTP/FTPS logout. 0 is success. Other values are failure.
FI
Examples
O
C
15.4.5
N
AT+CFTPSLOGOUT
OK
+CFTPSLOGOUT: 0
AT+CFTPSMKD Create a new directory on FTPS server
M
Description
C
O
This command is used to create a new directory on the FTPS server. The maximum length of
the full path name is 256.
SIM PIN References
Vendor
M
YES
SI
Syntax
Test Command
AT+CFTPSMKD=?
Write Command
AT+CFTPSMKD=”<dir>”
Responses
+CFTPSMKD: ”DIR”
OK
Responses
OK
+CFTPSMKD: <err>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
327
2017-12-25
Smart Machine Smart Decision
ERROR
ERROR
Defined values
FI
L
E
<dir>
The directory to be created
Examples
TI
AT+CFTPSRMD
Delete a directory on FTPS server
EN
15.4.6
AL
AT+CFTPSMKD=”testdir”
OK
AT+CFTPSMKD={non-ascii}”74657374646972”
OK
Description
Vendor
N
YES
References
FI
SIM PIN
D
This command is used to delete a directory on FTPS server
Responses
+CFTPSRMD: ”DIR”
OK
Responses
OK
C
Test Command
AT+CFTPSRMD=?
O
Syntax
+CFTPSRMD: <err>
ERROR
ERROR
M
C
O
M
Write Command
AT+CFTPSRMD=”<dir>”
Defined values
SI
<dir>
The directory to be removed. If the directory contains non-ASCII characters, the <dir> parameter
should contain a prefix of {non-ascii}.
Examples
AT+CFTPSRMD=”testdir”
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
328
2017-12-25
Smart Machine Smart Decision
AT+CFTPSRMD={non-ascii}”74657374646972”
OK
15.4.7
AT+CFTPSDELE
Delete a file on FTPS server
E
Description
SIM PIN
References
Vendor
AL
YES
FI
L
This command is used to delete a file on FTPS server
EN
+CFTPSDELE: <err>
ERROR
FI
Write Command
AT+CFTPSDELE=”<filena
me>”
Responses
+CFTPSDELE: ”FILENAME”
OK
Responses
OK
D
Test Command
AT+CFTPSDELE=?
TI
Syntax
N
ERROR
O
Defined values
Examples
M
C
<filename>
The name of the file to be deleted. If the file name contains non-ASCII characters, the <filename>
parameter should contain a prefix of {non-ascii}.
M
C
O
AT+CFTPSDELE=”test”
OK
AT+CFTPDELE={non-ascii}”74657374”
OK
SI
15.4.8 AT+CFTPSLIST List the items in the directory on FTPS server
Description
This command is used to list the items in the specified directory on FTPS server
SIM PIN
YES
References
Vendor
SIM7500_SIM7600 Series_AT Command Manual_V1.07
329
2017-12-25
Smart Machine Smart Decision
Syntax
Write Command
AT+CFTPSLIST=”<dir>”[,<
using_cache>]
Responses
If the <using_cache> is 0 (default):
FI
L
E
OK
+CFTPSLIST: DATA,<len>
…
+CFTPSLIST:<err>
AL
If the <using_cache> is 1:
OK
D
EN
AT+CFTPSCACHERD?
+CFTPSCACHERD: 102400
OK
TI
+CFTPS: RECV EVENT
O
N
FI
//output cached data now
AT+CFTPSCACHERD
+CFTPSLIST: DATA,<len>
…
OK
C
......
M
Execute Command
SI
M
C
O
AT+CFTPSLIST
+CFTPSLIST:<err>
ERROR
Responses
OK
+CFTPSLIST: DATA,<len>
…
+CFTPSLIST:<err>
OK
+CFTPSLIST:<err>
+CFTPSLIST:<err>
ERROR
ERROR
Defined values
<dir>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
330
2017-12-25
Smart Machine Smart Decision
FI
L
E
The directory to be listed. If the directory contains non-ASCII characters, the <dir> parameter
should contain a prefix of {non-ascii}.
<len>
The length of data reported
<err>
The result code of the listing
<using_cache>
0 – Do not use cache
1 – Use cache(Data will be output using AT+CFTPSCACHERD command)
AL
Examples
N
FI
D
EN
0 Sep 1 18:01 .
0 Sep 1 18:01 ..
2017 Sep 1 17:24 19800106_000128.jpg
0 Sep 1 18:01 .
0 Sep 1 18:01 ..
2017 Sep 1 17:24 19800106_000128.jpg
C
O
+CFTPSLIST: 0
AT+CFTPSLIST
OK
+CFTPSLIST: DATA,193
drw-rw-rw- 1 user
group
drw-rw-rw- 1 user
group
-rw-rw-rw- 1 user
group
+CFTPSLIST: 0
TI
AT+CFTPSLIST=”/testd”
OK
+CFTPSLIST: DATA,193
drw-rw-rw- 1 user
group
drw-rw-rw- 1 user
group
-rw-rw-rw- 1 user
group
AT+CFTPSGETFILE
Get a file from FTPS server to EFS
M
15.4.9
O
Description
C
This command is used to download a file from FTPS server to module EFS.
SIM PIN
Vendor
SI
M
YES
References
Syntax
Test Command
AT+CFTPSGETFILE=?
Write Command
AT+CFTPGETFILE=
Responses
+CFTPSGETFILE: [{non-ascii}]"FILEPATH",(0)[,(0-2147483647)]
OK
Responses
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
331
2017-12-25
Smart Machine Smart Decision
“<filepath>”,<dir>[,<rest_siz
e>]
+CFTPSGETFILE: 0
+CFTPSGETFILE: <err>
ERROR
ERROR
FI
L
E
OK
+CFTPSGETFILE: <err>
Defined values
EN
TI
AL
<filepath>
The remote file path. When the file path doesn’t contain ”/”, this command transfers file from the
current remote FTPS directory. If the file path contains non-ASCII characters, the file path
parameter should contain a prefix of {non-ascii}.
<dir>
The directory to save the downloaded file, refer to AT+FSCD.
<rest_size>
The rest size of the file.
FI
D
<err>
The error code of FTPS operation.
Examples
SI
M
C
O
M
C
O
N
AT+CFTPSGETFILE=”/pub/mydir/test1.txt”,1
OK
…
+CFTPSGETFILE: 0
AT+CFTPSGETFILE=” test2.txt”,2
OK
…
+CFTPSGETFILE: 0
AT+CFTPSGETFILE={non-ascii}” B2E2CAD42E747874”,2
OK
…
+CFTPSGETFILE: 0
AT+CFTSPGETFILE=?
OK
15.4.10 AT+CFTPSPUTFILE
Upload a file in module EFS to FTPS server
Description
This command is used to upload a file in the module EFS to FTPS server.
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
332
2017-12-25
Smart Machine Smart Decision
YES
Vendor
Syntax
Test Command
AT+CFTPSPUTFILE=?
Responses
E
+CFTPSPUTFILE: [{non-ascii}]"FILEPATH",(0)[,(0-2147483647)]
OK
FI
L
Responses
OK
+CFTPSPUTFILE: 0
+CFTPSPUTFILE: <err>
ERROR
AL
Write Command
AT+CFTPSPUTFILE=
“<filepath>”,<dir>[,<rest_siz
e>]
EN
OK
+CFTPSPUTFILE: <err>
TI
ERROR
Defined values
O
Examples
M
C
O
N
FI
D
<filepath>
The remote file path. When the file path doesn’t contain “/”, this command transfers file to the
current remote FTPS directory. If the file path contains non-ASCII characters, the file path
parameter should contain a prefix of {non-ascii}.
<dir>
The directory that contains the file to be uploaded, refer to AT+FSCD.
<rest_size>
The rest size of the file.
<err>
The error code of FTPS operation.
SI
M
C
AT+CFTPSPUTFILE=”/pub/mydir/test1.txt”,1
OK
AT+CFTPSPUTFILE=” test2.txt”,1
OK
…
+CFTPSPUTFILE: 0
AT+CFTPSPUTFILE={non-ascii}” B2E2CAD42E747874”,1
OK
…
+CFTPSPUTFILE: 0
AT+CFTPSPUTFILE=?
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
333
2017-12-25
Smart Machine Smart Decision
15.4.11 AT+CFTPSGET Get a file from FTPS server to serial port
Description
YES
References
FI
L
SIM PIN
E
This command is used to get a file from FTPS server and output it to serial port. This command
may have a lot of DATA transferred to DTE using serial port, The AT+CATR command is
recommended to be used.
Vendor
AL
Syntax
Responses
OK
Responses
AT+CFTPSGET=“<filepath
>”[,<rest_size>[,<using_cac
he>][,<cache>]]
If the <using_cache> is 0 (default):
OK
+CFTPSGET: DATA,<len>
…
+CFTPSGET: DATA, <len>
…
…
+CFTPSGET: 0
O
N
FI
D
EN
TI
Test Command
AT+CFTPSGET=?
Write Command
SI
M
C
O
M
C
If the <using_cache> is 1:
OK
+CFTPS: RECV EVENT
AT+CFTPSCACHERD?
+CFTPSCACHERD: 102400
OK
//output cached data now:
AT+CFTPSCACHERD
+CFTPSGET: DATA,<len>
…
OK
......
+CFTPSGET: 0
+CFTPSGET: <err>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
334
2017-12-25
Smart Machine Smart Decision
ERROR
ERROR
FI
L
E
+CFTPSGET: DATA, <len>
…
+CFTPSGET: DATA, <len>
…
…
+CFTPSGET: <err>
AL
Defined values
Examples
M
C
O
N
FI
D
EN
TI
<filepath>
The remote file path. When the file path doesn’t contain ”/”, this command transfer file from the
current remote FTPS directory. If the file path contains non-ASCII characters, the file path
parameter should contain a prefix of {non-ascii}.
<rest_size>
The rest size of the file.
<using_cache>
0 – Do not use cache
1 – Use cache(Data will be output using AT+CFTPSCACHERD command)
<cache>
Download delta package from the FTP/FTPS server into dir /cache (mainly for AT+CDELTA
update the module software version )
<len>
The length of FTPS data contained in this packet.
<err>
The error code of FTPS operation.
C
O
AT+CFTPSGET=”/pub/mydir/test1.txt”
OK
+CFTPSGET: DATA, 1020,
…
M
+CFTPSGET: DATA, 1058,
SI
…
…
+CFTPSGET: 0
AT+CFTPSGET={non-ascii}”/2F74657374646972/B2E2CAD42E747874”
OK
+CFTPSGET: DATA, 1020,
…
+CFTPSGET: 0
SIM7500_SIM7600 Series_AT Command Manual_V1.07
335
2017-12-25
Smart Machine Smart Decision
AT+CFTPSGET= "/update_ota.zip",0,0,"/cache"
OK
AT+CFTPSGET=?
OK
E
15.4.12 AT+CFTPSPUT Put a file to FTPS server
FI
L
Description
TI
Vendor
EN
YES
AL
This command is used to put a file to FTPS server through serial port. The AT+CFTPSPUT=
[“<filepath>”,]<len>[,<rest_size>] is used to download the data to be sent. The
AT+CFTPSPUT is used to wait the result of sending. Only parameter “<filepath>” is provided,
<rest_size> is optional, in other case <rest_size> is not used.
SIM PIN References
Syntax
Responses
D
Test Command
AT+CFTPSPUT=?
Read Command
AT+CFTPSPUT?
OK
C
O
Write Command
AT+CFTPSPUT=[“<filepath
>”,]<len>[,<rest_size>]
N
FI
Responses
+CFTPSPUT: <unsent_len>
OK
Responses
>
OK
+CFTPSPUT: <result>
ERROR
ERROR
Responses
M
Execute Command
OK
+CFTPSPUT: <result>
ERROR
M
C
O
AT+CFTPSPUT
SI
Defined values
<filepath>
The path of the file on FTPS server.
<unsent_len>
The length of the data in the sending buffer which is waiting to be sent.
<len>
The length of the data to send, the maximum length is 1024.
<rest_size>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
336
2017-12-25
Smart Machine Smart Decision
The rest size of the file.
<result>
The final result of the sending.
Examples
TI
AL
FI
L
E
AT+CFTPSPUT=”t1.txt”,10
>testcontent
OK
AT+CFTPSPUT
OK
+CFTPSSPUT: 0
AT+CFTPSPUT?
+CFTPSPUT: 88
OK
EN
15.4.13 AT+CFTPSSINGLEIP Set FTPS data socket address type
D
Description
SIM PIN
References
Vendor
N
YES
FI
This command is used to set FTPS server data socket IP address type
C
O
Syntax
Test Command
AT+CFTPSSINGLEIP=?
O
M
Read Command
AT+CFTPSSINGLEIP?
ERROR
SI
M
C
Write Command
AT+CFTPSSINGLEIP=<sin
gleip>
Responses
+CFTPSSINGLEIP: (0,1)
OK
Responses
+ CFTPSSINGLEIP: <singleip>
OK
Responses
OK
Defined values
<singleip>
The FTPS data socket IP address type:
0 – decided by PORT response from FTPS server
1 – the same as the control socket.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
337
2017-12-25
Smart Machine Smart Decision
Examples
FI
L
E
AT+CFTPSSINGLEIP=1
OK
AT+CFTPSSINGLEIP?
+CFTPSSINGLEIP:1
OK
AT+CFTPSSINGLEIP=?
+CFTPSSINGLEIP: (0,1)
OK
AL
15.4.14 AT+CFTPSCACHERD Output cached data to MCU
TI
Description
SIM PIN
References
D
Vendor
FI
YES
EN
This command is used to output cached data(generated by AT+CFTPSGET/AT+CFTPSLIST) to
MCU.
O
Responses
+CFTPSCACHERD: <len>
OK
Responses
If cache data is AT+CFTPSGET:
+CFTPSGET: DATA,<out_len><CR><LF>
…
OK
C
Read Command
AT+CFTPSCACHERD?
N
Syntax
SI
M
C
O
M
Execute Command
AT+CFTPSCACHERD
If the cache data is AT+CFTPSLIST:
+CFTPSLIST: DATA,<out_len><CR><LF>
…
OK
ERROR
Defined values
<len>
The bytes of data cached in FTPS module.
<out_len>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
338
2017-12-25
Smart Machine Smart Decision
The bytes of data to output. The maximum value is 1024 for each AT+CFTPSCACHERD calling.
Examples
FI
L
E
AT+CFTPSCACHERD?
+CFTPSCACHERD: 102400
OK
AT+CFTPSCACHERD
+CFTPSGET: DATA, 1024
…
AL
OK
Description
PEER
The FTPS session is closed by the server.
D
+CFTPSNOTIFY:
CLOSED
EN
Code
TI
15.4.15 Unsolicited FTPS Codes
FI
15.4.16 Unsolicited FTPS command <err> Codes
O
O
M
C
FTPS busy
FTPS server closed connection
Timeout
FTPS transfer failed
FTPS memory error
Invalid parameter
Operation rejected by FTPS server
Network error
M
C
3
4
5
6
7
8
9
10
FTPS operation succeeded
SSL verify alert
Unknown FTPS error
N
0
1
2
HTTP
SI
15.5
15.5.1
AT+CHTTPACT
Launch a HTTP operation
Description
This command is used to launch a HTTP operation like GET or POST. Each <Ctrl+Z> character
presented in the data flow of serial port will be coded as <ETX><Ctrl+Z>. Each <ETX> character
SIM7500_SIM7600 Series_AT Command Manual_V1.07
339
2017-12-25
Smart Machine Smart Decision
YES
References
AL
SIM PIN
FI
L
E
will be coded as <ETX><ETX>. Single <Ctrl+Z> means end of the HTTP request data or end of
the HTTP responded data.
<ETX> is 0x03, and <Ctrl+Z> is 0x1A.
For this command there may be a lot of DATA which need to be transferred to DTE using serial
port, it is recommended that the AT+CATR will be used.
NOTE: For HTTP/HTTPS operation, The “Secure Hyper Text Transfer Protocol Service” chapter
AT set is recommended to be used. The AT+CHTTPACT is only used to support old HTTP
application.
Vendor
TI
Syntax
Responses
+CHTTPACT: “ADDRESS”, (1-65535)
OK
Responses
+CHTTPACT: REQUEST
+CHTTPACT: DATA, <len>
…
+CHTTPACT: DATA, <len>
…
…
+CHTTPACT: 0
EN
Test Command
AT+CHTTPACT=?
C
O
N
FI
D
Write Command
AT+CHTTPACT=
“<address>”,<port>
SI
M
C
O
M
+CME ERROR
+CHTTPACT: <err>
ERROR
+CHTTPACT: REQUEST
+CHTTPACT: <err>
ERROR
+CHTTPACT: REQUEST
+CHTTPACT: DATA, <len>
…
+CHTTPACT: DATA, <len>
…
…
+CHTTPACT: <err>
ERROR
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
340
2017-12-25
Smart Machine Smart Decision
FI
L
E
<address>
The HTTP server domain name or IP address.
<port>
The HTTP server port.
<len>
The length of HTTP data in the packet.
<err>
The error code of HTTP operation.
TI
C
O
N
FI
D
EN
AT+CHTTPACT=”www.mywebsite.com”,80
+CHTTPACT: REQUEST
GET http://www.mywebsite.com/index.html HTTP/1.1
Host: www.mywebsite.com
User-Agent: MY WEB AGENT
Content-Length: 0
<Ctrl+Z>
OK
+CHTTPACT: DATA, 249
HTTP/1.1 200 OK
Content-Type: text/html
Content-Language: zh-CN
Content-Length: 57
Date: Tue, 31 Mar 2009 01:56:05 GMT
Connection: Close
Proxy-Connection: Close
AL
Examples
SI
M
C
O
M
<html>
<header>test</header>
<body>
Test body
</body>
+CHTTPACT: 0
AT+CHTTPACT=”www.mywebsite.com”,80
+CHTTPACT: REQUEST
POST http://www.mywebsite.com/mydir/test.jsp HTTP/1.1
Host: www.mywebsite.com
User-Agent: MY WEB AGENT
Accept: */*
Content-Type: application/x-www-form-urlencoded
Cache-Control: no-cache
Accept-Charset: utf-8, us-ascii
SIM7500_SIM7600 Series_AT Command Manual_V1.07
341
2017-12-25
Smart Machine Smart Decision
Pragma: no-cache
Content-Length: 29
FI
L
AL
TI
EN
D
FI
Unsolicited HTTP codes (summary of CME ERROR codes)
C
15.5.2
O
N
<html>
<header>result</header>
<body>
Result is OK
</body>
+CHTTPACT: 0
AT+CHTTPACT=?
+CHTTPACT: “ADDRESS”,(1-65535)
OK
E
myparam1=test1&myparam2=test2<Ctrl+Z>
OK
+CHTTPACT: DATA, 234
HTTP/1.1 200 OK
Content-Type: text/html
Content-Language: zh-CN
Content-Length: 54
Date: Tue, 31 Mar 2009 01:56:05 GMT
Connection: Close
Proxy-Connection: Close
Description
Unknown error for HTTP
HTTP task is busy
Failed to resolve server address
223
224
225
226
227
HTTP timeout
Failed to transfer data
Memory error
Invalid parameter
Network error
SI
M
C
O
M
Code of <err>
220
221
222
SIM7500_SIM7600 Series_AT Command Manual_V1.07
342
2017-12-25
Smart Machine Smart Decision
15.6
HTTPS
15.6.1
AT+CHTTPSSTART Acquire HTTPS protocol stack
E
Description
SIM PIN
References
Vendor
AL
YES
FI
L
This command is used to acquire HTTPS protocol stack.
Syntax
Responses
AT+CHTTPSSTART
OK
EN
TI
Execute Command
+CHTTPSSTART: <err>
D
ERROR
FI
Defined values
O
N
<err>
The result code of the start HTTPS service. 0 is success. Other values are failure.
AT+CHTTPSSTART
OK
C
Examples
O
M
+CHTTPSSTART: 0
AT+CHTTPSSTOP Stop HTTPS protocol stack
C
15.6.2
M
Description
This command is used to stop HTTPS protocol stack.
SI
SIM PIN
YES
References
Vendor
Syntax
Execute Command
Responses
AT+CHTTPSSTOP
+CHTTPSSTOP: <err>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
343
2017-12-25
Smart Machine Smart Decision
OK
ERROR
Examples
AL
AT+CHTTPSSTOP
+CHTTPSSTOP: 0
EN
TI
OK
15.6.3
FI
L
<err>
The result code of the stop HTTPS service. 0 is success. Other values are failure.
E
Defined values
AT+CHTTPSOPSE
Open HTTPS session
D
Description
Vendor
Syntax
Write Command
C
O
YES
References
N
SIM PIN
FI
This command is used to open a new HTTPS session. Every time, AT+CHTTPSSTART command
must be executed before executing AT+CHTTPSOPSE command.
OK
+CHTTPSOPSE: <err>
ERROR
C
O
M
AT+CHTTPSOPSE=”<host
>”,<port>[,<server_type>]
Responses
M
Defined values
SI
<port>
The host listening port for SSL
<server_type>
The type of server:
1 – HTTP server.
2 – HTTPS server with SSL3.0/TLS1.0 supported.
<err>
The result code of the open common channel. 0 is success. Other values are failure.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
344
2017-12-25
Smart Machine Smart Decision
Examples
AT+CHTTPSOPSE=”www.mywebsite.com”,443
OK
AT+CHTTPSCLSE Close HTTPS session
FI
L
15.6.4
E
+CHTTPSOPSE: 0
Description
SIM PIN
References
Vendor
TI
YES
AL
This command is used to close the opened HTTPS session.
Responses
AT+CHTTPSCLSE
OK
D
Execute Command
EN
Syntax
FI
+CHTTPSCLSE: <err>
N
ERROR
O
Defined values
Examples
M
C
<err>
The result code of the closing common channel. 0 is success. Other values are failure.
C
O
AT+CHTTPSCLSE
OK
M
+CHTTPSCLSE: 0
SI
15.6.5
AT+CHTTPSSEND Send HTTPS request
Description
This command is used to send HTTPS request. The AT+CHTTPSSEND=<len> is used to download
the data to be sent. The AT+CHTTPSSEND is used to wait the result of sending.
SIM PIN
YES
References
Vendor
SIM7500_SIM7600 Series_AT Command Manual_V1.07
345
2017-12-25
Smart Machine Smart Decision
Syntax
Write Command
AT+CHTTPSSEND=<len>
ERROR
Responses
>
OK
AL
Read Command
AT+CHTTPSSEND?
ERROR
Responses
+CHTTPSSEND: <unsent_len>
OK
EN
OK
+CHTTPSSEND: <result>
ERROR
FI
Defined values
D
AT+CHTTPSSEND
TI
ERROR
Responses
Execute Command
E
Responses
+CHTTPSSEND: (1-2048)
OK
FI
L
Test Command
AT+CHTTPSSEND=?
SI
M
C
O
M
C
O
N
<unsent_len>
The length of the data in the sending buffer which is waiting to be sent.
<len>
The length of the data to send
<result>
The final result of the sending.
0 – ok
1 – unknown error
2 – busy
3 – server closed
4 – timeout
5 – transfer failed
6 – memory error
7 – invalid parameter
8 – network error
Examples
AT+CHTTPSSEND=88
>GET / HTTP/1.1
Host: www.mywebsite.com
User-Agent: MY WEB AGENT
SIM7500_SIM7600 Series_AT Command Manual_V1.07
346
2017-12-25
Smart Machine Smart Decision
Content-Length: 0
Description
FI
L
AT+CHTTPSRECV Receive HTTPS response
AL
15.6.6
E
OK
AT+CHTTPSSEND
OK
+CHTTPSSEND: 0
AT+CHTTPSSEND?
+CHTTPSSEND: 88
OK
YES
References
EN
SIM PIN
TI
This command is used to receive HTTPS response after sending HTTPS request.
Vendor
D
Syntax
Responses
+CHTTPSRECV: LEN, <cache_len>
OK
N
FI
Read Command
AT+CHTTPSRECV?
O
ERROR
Responses
C
Write Command
OK
+CHTTPSRECV: DATA, <len>
…
+CHTTPSRECV: DATA, <len>
…
+CHTTPSRECV: <result>
+CHTTPSRECV: <result>
ERROR
ERROR
SI
M
C
O
M
AT+CHTTPSRECV=<max_
recv_len>
Defined values
<max_recv_len>
Maximum bytes of data to receive in the current AT+CHTTPSRECV calling. Minimum is 1.
<cache_len>
The cache length.
<result>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
347
2017-12-25
Smart Machine Smart Decision
FI
L
E
The final result of the receiving.
0 – ok
1 – unknown error
2 – busy
3 – server closed
4 – timeout
5 – transfer failed
6 – memory error
7 – invalid parameter
8 – network error
TI
EN
D
FI
O
M
C
<html>
<header>test</header>
<body>
Test body
</body>
N
AT+CHTTPSRECV=249
OK
+CHTTPSRECV: DATA,249
HTTP/1.1 200 OK
Content-Type: text/html
Content-Language: zh-CN
Content-Length: 57
Date: Tue, 31 Mar 2009 01:56:05 GMT
Connection: Close
Proxy-Connection: Close
AL
Examples
O
+CHTTPSRECV: 0
AT+CHTTPSSTATE Get the state of HTTPS stack
C
15.6.7
M
Description
SI
This command is used to get the state of HTTPS stack.
SIM PIN
NO
References
Vendor
Syntax
Execute Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
348
2017-12-25
Smart Machine Smart Decision
AT+CHTTPSSTATE
+CHTTPSSTATE: <state>
OK
ERROR
TI
AL
FI
L
None
Accquired HTTPS
Opening network
Closing network
Opened network
Closing session
Opening session
Opened session.
EN
<state>
0 –
1 –
2 –
3 –
4 –
5 –
6 –
7 –
E
Defined values
Examples
FI
N
Unsolicited HTTPS Codes
Code
O
15.6.8
D
AT+CHTTPSSTATE
+CHTTPSSTATE: 0
OK
Description
When the AT+CHTTPSRECV is not called, and there is data
cached in the receiving buffer, this event will be reported.
C
+CHTTPS: RECV EVENT
The HTTPS session is closed by the server.
Unsolicited HTTPS command <err> Codes
C
O
15.6.9
PEER
M
+CHTTPSNOTIFY:
CLOSED
SI
M
0
1
2
3
4
5
6
7
8
Operation succeeded
Unknown error
Busy
Server closed
Operation timeout
Transfer failed
Memory error
Invalid parameter
Network error
SIM7500_SIM7600 Series_AT Command Manual_V1.07
349
2017-12-25
Smart Machine Smart Decision
15.7
HTP
These AT Commands of HTP related are used to synchronize system time with HTTP server.
AT+CHTPSERV Set HTP server info
E
15.7.1
FI
L
Description
This command is used to add or delete HTP server information. There are maximum 16 HTP
servers.
Vendor
TI
YES
References
AL
SIM PIN
Syntax
Responses
+CHTPSERV:"ADD","HOST",(1-65535),
(0-1)[,"PROXY",(1-65535)]
+CHTPSERV: "DEL",(0-15)
OK
Read Command
Responses
AT+CHTPSERV?
+CHTPSERV:<index>"<host>",<port>,<http_version>
[,"<proxy>",<proxy_port>]
…
+CHTPSERV:<index>"<host>",<port>[,"<proxy>",< proxy_port>]
OK
C
O
N
FI
D
EN
Test Command
AT+CHTPSERV=?
OK (if HTP server not setted)
Responses
AT+CHTPSERV=
"<cmd>","<host_or_idx>"[,<
port>,<http_version>
[,"<proxy>",<proxy_port>]]
OK
ERROR
M
C
O
M
Write Command
SI
Defined values
<cmd>
This command to operate the HTP server list.
“ADD”: add a HTP server item to the list
“DEL”: delete a HTP server item from the list
<host_or_idx>
If the <cmd> is “ADD”, this field is the same as <host>, needs quotation marks; If the <cmd> is
“DEL”, this field is the index of the HTP server item to be deleted from the list, does not need
SIM7500_SIM7600 Series_AT Command Manual_V1.07
350
2017-12-25
Smart Machine Smart Decision
Examples
Updating date time using HTP protocol
N
AT+CHTPUPDATE
O
15.7.2
FI
D
AT+CHTPSERV=”ADD”,”www.google.com”,80,1
OK
EN
TI
AL
FI
L
E
quotation marks.
<host>
The HTP server address.
<port>
The HTP server port.
<http_version>
The HTTP version of the HTP server:
0- HTTP 1.0
1- HTTP 1.1
<proxy>
The proxy address
<proxy_port>
The port of the proxy
<index>
The HTP server index.
Description
SIM PIN
Vendor
O
Syntax
References
M
YES
C
This command is used to updating date time using HTP protocol.
SI
M
C
Test Command
AT+CHTPUPDATE=?
Read Command
AT+CHTPUPDATE?
Execute Command
AT+CHTPUPDATE
Responses
OK
Response
+CHTPUPDATE:<status>
OK
Responses
OK
+CHTPUPDATE: <err>
ERROR
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
351
2017-12-25
Smart Machine Smart Decision
E
<status>
The status of HTP module:
Updating: HTP module is synchronizing date time
NULL: HTP module is idle now
<err>
The result of the HTP updating
FI
L
Examples
TI
Unsolicited HTP Codes
EN
15.7.3
AL
AT+CHTPUPDATE
OK
+CHTPUPDATE: 0
Description
Operation succeeded
Unknown error
Wrong parameter
3
4
Wrong date and time calculated
Network error
O
NTP
C
15.8
N
FI
D
Code of <err>
0
1
2
These AT Commands of NTP related are used to synchronize system time with NTP server.
AT+CNTP update system time
M
15.8.1
O
Description
C
This command is used to update system time with NTP server.
M
SIM PIN
Vendor
SI
YES
References
Syntax
Test Command
AT+CNTP=?
Read Command
Responses
+CNTP: 64,(-47~48)
OK
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
352
2017-12-25
Smart Machine Smart Decision
ezone>]
ERROR
Write Command
Responses
AT+CNTP
OK
+CNTP:<err_code>
Write Command
E
AT+CNTP=”<host>”[,<tim
+CNTP: <host>[,<timezone>]
OK
Responses
OK
FI
L
AT+CNTP?
AL
ERROR
EN
<host>
NTP server address,length is 64.
<timezone>
Local time zone,the range is(-47 to 48),default value is 32.
FI
N
O
AT+CNTP="202.120.2.101",32
OK
AT+CNTP
OK
+CNTP: 0
D
Examples
Unsolicited NTP Codes
C
15.8.2
TI
Defined values
Description
Operation succeeded
Unknown error
Wrong parameter
3
4
Wrong date and time calculated
Network error
M
C
O
M
Code of <err>
0
1
2
Common Channel Service
SI
15.9
The common channel related AT commands needs the AT+CATR to be set to the used port.
AT+CATR=0 may cause some problem.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
353
2017-12-25
Smart Machine Smart Decision
15.9.1
AT+CCHSTART Acquire common channel service
Description
This command is used to acquire common channel service.
Vendor
FI
L
YES
References
E
SIM PIN
Responses
AT+CCHSTART
OK
+CCHSTART: <err>
EN
+CCHSTART: <err>
OK
ERROR
D
Defined values
TI
Execute Command
AL
Syntax
N
FI
<err>
The result code of the acquiring common channel service. 0 is success. Other values are failure.
AT+CCHSTOP Stop common channel service
M
15.9.2
C
AT+CCHSTART
OK
+CCHSTART: 0
O
Examples
O
Description
C
This command is used to stop common channel service.
M
SIM PIN
Vendor
SI
YES
References
Syntax
Execute Command
Responses
AT+CCHSTOP
OK
+CCHSTOP: <err>
+CCHSTOP: <err>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
354
2017-12-25
Smart Machine Smart Decision
OK
ERROR
FI
L
<err>
The result code of the stoping common channel service. 0 is success. Other values are failure.
Examples
TI
AL
AT+CCHSTOP
OK
+CCHSTOP: 0
AT+CCHOPEN Open a channel
EN
15.9.3
E
Defined values
Description
This command is used to connect peer using common channel service.
Vendor
FI
YES
References
D
SIM PIN
M
Write Command
C
O
AT+CCHOPEN=<session_i
d>, ”<host>”,<port>[<chann
el_type>,[<bind_port>]]
of
<port>s[,list
of
OK
+CCHOPEN: <session_id>,<err>
+CCHOPEN: <session_id>,<err>
OK
ERROR
SI
M
Responses
+CCHOPEN:
(0,1),”ADDRESS”,list
<channel_type>s [,list of <bind_port>s]]
OK
Responses
C
Test Command
AT+CCHOPEN=?
O
N
Syntax
Defined values
<session_id>
The session index to operate. It’s from 0 to 1.
<host>
The host address, maximum length is 256
<port>
SIM7500_SIM7600 Series_AT Command Manual_V1.07
355
2017-12-25
Smart Machine Smart Decision
FI
L
TI
D
Close a channel
FI
AT+CCHCLOSE
EN
AT+CCHOPEN=0, ”www.myserver.com”,443,2
OK
+CCHOPEN: 0 0
AT+CCHOPEN=0, ”www.myserver.com”,443,1
OK
+CCHOPEN: 0,0
AL
Examples
15.9.4
E
The peer port for channel, the range is from 1 to 65535
<channel_type>
The type of channel:
1 – TCP client.
2 – SSLv3.0/TLSv1.0 client.
<bind_port>
The local port for channel, the range is from 1 to 65535
<err>
The result code of the opening common channel. 0 is success. Other values are failure.
Description
Vendor
C
YES
References
O
SIM PIN
N
This command is used to disconnect from peer.
Syntax
Responses
AT+CCHCLOSE=<session_
id>
OK
+CCHCLOSE: <session_id>,<err>
+CCHCLOSE: <session_id>,<err>
OK
ERROR
SI
M
C
O
M
Write Command
Defined values
<session_id>
The session index to operate. It’s from 0 to 1.
<err>
The result code of the closing common channel. 0 is success. Other values are failure.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
356
2017-12-25
Smart Machine Smart Decision
Examples
AT+CCHCLOSE=0
OK
+CCHCLOSE: 0,0
E
AT+CCHSEND Send data to peer
FI
L
15.9.5
Description
Vendor
TI
YES
AL
This command is used to send data to peer. If the first parameter of AT+CCHSET is set to 1,
the +CCHSEND: <session_id>, <err> will be reported after AT+CCHSEND is finished.
SIM PIN References
EN
Syntax
Responses
+CCHSEND: (0,1),(1-2048)
OK
Responses
+CCHSEND: 0,<unsent_len_0>,1,<unsent_len_1>
OK
Responses
D
Test Command
AT+CCHSEND=?
N
FI
Read Command
AT+CCHSEND?
O
Write Command
>
OK
C
AT+CCHSEND=<session_i
d>,<len>
ERROR
M
Defined values
SI
M
C
O
<session_id>
The session index to operate. It’s from 0 to 1.
<len>
The length of data to send. Its range is from 1 to 2048.
<unsent_len_0>
The data of channel session 0 cached in DS layer which is waiting to be sent.
<unsent_len_1>
The data of channel session 1 cached in DS layer which is waiting to be sent.
Examples
AT+CCHSEND=0, 125
>GET / HTTP/1.1
Host: www.google.com.hk
SIM7500_SIM7600 Series_AT Command Manual_V1.07
357
2017-12-25
Smart Machine Smart Decision
User-Agent: MAUI htp User Agent
Proxy-Connection: keep-alive
Content-Length: 0
AT+CCHRECV Receive data from the channel
FI
L
15.9.6
E
OK
Description
This command is used to receive data from the channel.
Vendor
TI
YES
References
AL
SIM PIN
EN
Syntax
Responses
+CCHRECV: LEN,<cache_len_0>,<cache_len_1>
OK
Responses
OK
[+CCHRECV: DATA, <session_id>,<len>
…
+CCHRECV: DATA, <session_id>,<len>
…]
+CCHRECV: <session_id>,<result>
C
O
AT+CCHRECV=<session_i
d>[,<max_recv_len>]
N
Write Command
FI
D
Read Command
AT+CCHRECV?
ERROR
+CCHRECV: <session_id>,<result>
ERROR
C
O
M
+CCHRECV: <session_id>,<result>
ERROR
M
Defined values
SI
<session_id>
The session index to operate. It’s from 0 to 1.
<max_recv_len>
Maximum bytes of data to receive in the current AT+CCHRECV calling, the value can’t be greater
than the length of RX data cached for session <session_id>. The range of this value is 0 to the data
length in the receive buffer.
0 means the maximum bytes to receive is 2048. (But, when 2048 is greater than the length of RX
data cached for session <session_id>, 0 means the length of RX data cached for session
SIM7500_SIM7600 Series_AT Command Manual_V1.07
358
2017-12-25
TI
EN
D
FI
O
M
C
<html>
<header>test</header>
<body>
Test body
</body>
N
AT+CCHRECV=1
OK
+CCHRECV: DATA,1,249
HTTP/1.1 200 OK
Content-Type: text/html
Content-Language: zh-CN
Content-Length: 57
Date: Tue, 31 Mar 2009 01:56:05 GMT
Connection: Close
Proxy-Connection: Close
AL
Examples
FI
L
<session_id>).
The default value is the length of RX data cached for session <session_id>.
<cache_len_0>
The length of RX data cached for session 0.
<cache_len_1>
The length of RX data cached for session 1.
<result>
The final result according to Unsolicited common channel command <err> Codes
<len>
The length of data followed.
E
Smart Machine Smart Decision
O
+CCHRECV:1, 0
AT+CCHSET Set the parameter of common channel service
C
15.9.7
M
Description
SI
This command is set the parameter of common channel service. It must be called before
AT+CCHSTART.
SIM PIN References
YES
Vendor
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
359
2017-12-25
Smart Machine Smart Decision
Read Command
AT+CCHSET?
Write Command
OK
ERROR
AL
AT+CCHSET=<report_send
_result>[,<recv_mode>]
E
Responses
+CCHSET: (0,1),(0,1)
OK
Responses
+CCHSET: <report_send_result>,<recv_mode>
OK
Responses
FI
L
Test Command
AT+CCHSET=?
Defined values
N
FI
D
EN
TI
<report_send_result>
Whether to report result of CCHSEND:
0 – No.
1 – Yes.
<recv_mode>
The receiving mode:
0 – Output the data to MCU whenever received data.
1 – Module caches the received data and notify MCU with +CCHEVENT: <session_id>,
RECV EVENT. MCU can use AT+CCHRECV to receive the cached data(manual receiving mode).
AT+CCHADDR
Get the IPv4 address for common channel service
M
15.9.8
C
AT+CCHSET=1,1
OK
O
Examples
O
Description
This command is used to get the IPv4 address after calling AT+CCHSTART.
C
SIM PIN
M
YES
References
Vendor
SI
Syntax
Execute Command
Responses
AT+CCHADDR
+CCHADDR: < ip_address>
OK
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
360
2017-12-25
Smart Machine Smart Decision
Defined values
<ip_address>
A string parameter that identifies the IPv4 address of the common channel service when connecting
to Packet network.
E
Examples
AL
15.9.9
FI
L
AT+CCHADDR
+CCHADDR: 10.71.155.118
OK
AT+CCERTVERIFY Set SSL server cert verify flag
TI
Description
SIM PIN
References
Vendor
D
NO
EN
The command is used to set the SSL server cert verify flag. Default is not verified.
N
C
Read Command
AT+CCERTVERIFY?
Responses
+CCERTVERIFY: (0,1)
OK
Responses
+CCERTVERIFY: <enable_flag>
OK
Responses
OK
O
Test Command
AT+CCERTVERIFY=?
FI
Syntax
Write Command
+CME ERROR
O
M
AT+CCERTVERIFY=<
enable_flag >
C
Defined values
SI
M
<enable_flag>
The cert verify enable flag:
0 – not verify the server cert.
1 – verify the server cert.
NOTE:
1. If enable the cert verified flag(AT+CCERTVERIFY=1), it need the server cert, user must
load cert file to the EFS before execute the relate open operation.
2. This setting influences the CCH and HTTPS functions.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
361
2017-12-25
Smart Machine Smart Decision
Examples
FI
L
E
AT+CCERTVERIFY=1
OK
AT+ CCERTVERIFY?
+ CCERTVERIFY: 1
OK
AT + CCERTVERIFY =?
+ CCERTVERIFY: (0,1)
OK
AL
15.9.10 Unsolicited common channel Codes
Description
+CCHEVENT:
<session_id>,RECV EVENT
In manual receiving mode, when new data of a channel arriving
to the module, this unsolicited result code will be reported to
MCU.
+CCH_PEER_CLOSED:
<session_id>
The channel is closed by the peer.
FI
D
EN
TI
Code
Operation succeeded
Alerting state(reserved)
Unknown error
Busy
Peer closed
Operation timeout
Transfer failed
Memory error
Invalid parameter
Network error
Open session error
State error
Create session error
Create socket error
Set ssl parameter error
Get dns error
Connect socket error
C
M
O
SI
M
C
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
O
N
15.9.11 Unsolicited common channel command <err> Codes
SIM7500_SIM7600 Series_AT Command Manual_V1.07
362
2017-12-25
Smart Machine Smart Decision
15.10 SSL Certificate & Key Management
15.10.1 AT+CCERTDOWN
Transfer a certificate file to Module
SIM PIN
Vendor
AL
NO
References
>
OK
FI
>
ERROR
EN
AT+CCERTDOWN=“<filen
ame>”,<len>
D
Responses
OK
Responses
TI
Syntax
Test Command
AT+CCERTDOWN=?
Write Command
FI
L
This command is used to transfer a certificate or key file to the module.
E
Description
N
ERROR
O
Defined values
O
Examples
M
C
<filename>
The name of the certificate/key file. The file name must have type like “.der” or “.pem”, and
the .pem file cannot be protected using password.
<len>
The length of the file data to send.
SI
M
C
AT+CCERTDOWN=”client_key.der”,611
>file content...
OK
15.10.2 AT+CCERTLIST List certificate/key in module
Description
This command is used to list certificate/key files which has already been downloaded to the
module.
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
363
2017-12-25
Smart Machine Smart Decision
NO
Vendor
Execution Command
AT+CCERTLIST
Responses
[
<list of files> with “+CCERTLIST:” header
<CR><LF>]
OK
FI
L
Responses
OK
AL
Test Command
AT+CCERTLIST=?
E
Syntax
TI
Defined values
EN
<list of files>
The certificate/key files which has been downloaded to the module.
FI
N
C
O
AT+CCERTLIST=?
OK
AT+CCERTLIST
+CCERTLIST: "ca_cert.der"
+CCERTLIST: "client_cert.der"
+CCERTLIST: "client_key.der"
+CCERTLIST: "server_cert.pem"
+CCERTLIST: "server_key.pem"
D
Examples
O
M
OK
Delete certificate/key in the module
C
15.10.3 AT+CCERTDELE
M
Description
SI
This command is used to delete a certificate/key file in the module.
SIM PIN
NO
References
Vendor
Syntax
Test Command
Responses
SIM7500_SIM7600 Series_AT Command Manual_V1.07
364
2017-12-25
Smart Machine Smart Decision
AT+CCERTDELE=?
OK
Write Command
AT+CCERTDELE=<filena
me>
Responses
OK
E
ERROR
<filename>
String with or with double quotes, file name which is relative and already existing.
AL
Examples
FI
L
Defined values
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AT+CCERTDELE=”server_key.pem”
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
365
2017-12-25
Smart Machine Smart Decision
16 AT Commands for Open/Close Network
AT+CNETSTART Open network
E
16.1
FI
L
Description
This command opens packet network.
Vendor
Syntax
EN
Responses
+CNETSTART: <net_state>
OK
FI
ERROR
D
Read Command
AT+CNETSTART?
TI
YES
References
AL
SIM PIN
Responses
OK
O
N
Execution Command
AT+CNETSTART
C
+CNETSTART: <err>
+ CNETSTART: <err>
+CNETSTART: <err>
ERROR
ERROR
M
C
O
M
OK
SI
Defined values
<net_state>
a numeric parameter that indicates the state of PDP context activation:
0
network close (deactivated)
1 network is opening
2 network open(activated)
3 network is closing
<err >
SIM7500_SIM7600 Series_AT Command Manual_V1.07
366
2017-12-25
Smart Machine Smart Decision
The result of operation, 0 is success, other value is failure.
Examples
E
AT+CNETSTART
OK
FI
L
+CNETSTART: 0
AT+CNETSTART?
+CNETSTART: 2
TI
AT+CNETSTOP Close network
EN
16.2
AL
OK
Description
Vendor
N
YES
References
FI
SIM PIN
D
This command closes network. Before calling this command, all opened sockets must be closed
first.
Responses
OK
C
Execution Command
AT+CNETSTOP
O
Syntax
SI
M
C
O
M
+CNETSTOP: <err>
+CNETSTOP: <err>
OK
+CNETSTOP: <err>
ERROR
ERROR
Defined values
<err>
The result of operation, 0 is success, other value is failure.
Examples
SIM7500_SIM7600 Series_AT Command Manual_V1.07
367
2017-12-25
Smart Machine Smart Decision
AT+CNETSTOP
OK
+CNETSTOP: 0
E
AT+CNETIPADDR Inquire PDP address
FI
L
16.3
Description
This command inquires the IP address of current active PDP.
YES
References
AL
SIM PIN
Vendor
Responses
+CNETIPADDR: < ip_address>
EN
Read Command
AT+CNETIPADDR?
TI
Syntax
D
OK
FI
+CNETIPADDR: <err_info>
N
ERROR
C
Defined values
O
ERROR
O
M
<ip_address>
A string parameter that identifies the IP address of current active socket PDP.
<err_info>
A string parameter that displays the cause of occurring error.
C
Examples
SI
M
AT+CNETIPADDR?
+CNETIPADDR: 10.71.155.118
OK
16.4
Unsolicited CNETSTART/CNETSTOP Codes
Code of <err>
0
Description
Operation succeeded
SIM7500_SIM7600 Series_AT Command Manual_V1.07
368
2017-12-25
3
4
5
6
7
8
Close network failed
Network not opened
Operation not support
Busy
Network has been opened
Network is also in use
FI
L
Unknown error
Open network failed
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
1
2
E
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07
369
2017-12-25
Smart Machine Smart Decision
17 AT Commands for GPS
AT+CGPS Start/Stop GPS session
E
17.1
FI
L
Description
Vendor
Syntax
O
NO
References
C
SIM PIN
N
FI
D
EN
TI
AL
This command is used to start or stop GPS session.
NOTE:
1. Output of NMEA sentences is automatic; no control via AT commands is provided. At
present the module only supports standalone mode. If executing AT+CGPS=1, the GPS
session will choose cold or hot start automatically.
2. UE-based and UE-assisted mode depend on URL (AT+CGPSURL). When UE-based
mode fails, it will switch standalone mode.
3. UE-assisted mode is singly fixed. Standalone and UE-based mode is consecutively
fixed.
4. After the GPS closed, it should to wait about 2s~30s for start again. Reason:If the
signal conditions are right (strong enough signals to allow ephemeris demodulation) or
ephemeris demodulation is on going, sometimes MGP will stay on longer in order to
demodulate more ephemeris. This will help the engine provide faster TTFF and
possibly better yield later (up to 2 hours), because it has the benefit of more ephemeris
available.
Responses
+CGPS: (list of supported <on/off>s),( list of supported <mode>s)
OK
Read Command
AT+CGPS?
Responses
+CGPS: <on/off>,<mode>
OK
Write Command
AT+CGPS=<on/off>
[,<mode>]
Responses
OK
If UE-assisted mode, when fixed will report indication:
+CAGPSINFO:<lat>,<lon>,<alt>,<date>,<time>
If <off>, it will report indication:
+CGPS: 0
SI
M
C
O
M
Test Command
AT+CGPS=?
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
370
2017-12-25
Smart Machine Smart Decision
FI
L
O
N
FI
D
EN
TI
AL
<on/off>
0 – stop GPS session
1 – start GPS session
<mode>
Ignore - standalone mode
1 – standalone mode
2 – UE-based mode
3 – UE-assisted mode
<lat>
Latitude of current position. Unit is in 10^8 degree
<log>
Longitude of current position. Unit is in 10^8 degree
<alt>
MSL Altitude. Unit is meters.
<date>
UTC Date. Output format is ddmmyyyy
<time>
UTC Time. Output format is hhmmss.s
< unconfidence >
Unconfidence of the location, GPS fixed report 39, cell fixed report 100.
< uncertainty_meter >
Uncertainty meters.
E
Defined values
AT+CGPSINFO
C
17.2
O
M
AT+CGPS?
OK
AT+CGPS=1,1
OK
C
Examples
Get GPS fixed position information
M
Description
SI
This command is used to get current position information.
SIM PIN
NO
References
Vendor
Syntax
Test Command
AT+CGPSINFO=?
Responses
+CCGPSINFO: (scope of <time>)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
371
2017-12-25
Smart Machine Smart Decision
OK
Responses
AT+CGPSINFO?
+CCGPSINFO: <time>
OK
Write Command
AT+CGPSINFO=<time>
Responses
OK
+CGPSINFO: [<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC
time>],[<alt>],[<speed>],[<course>]
FI
L
E
Read Command
OK (if <time>=0)
Responses
+CGPSINFO: [<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC
time>],[<alt>],[<speed>],[<course>]
OK
TI
AL
Execution Command
AT+CGPSINFO
EN
Defined values
SI
M
C
O
M
C
O
N
FI
D
<lat>
Latitude of current position. Output format is ddmm.mmmmmm
<N/S>
N/S Indicator, N=north or S=south
<log>
Longitude of current position. Output format is dddmm.mmmmmm
<E/W>
E/W Indicator, E=east or W=west
<date>
Date. Output format is ddmmyy
<UTC time>
UTC Time. Output format is hhmmss.s
<alt>
MSL Altitude. Unit is meters.
<speed>
Speed Over Ground. Unit is knots.
<course>
Course. Degrees.
<time>
The range is 0-255, unit is second, after set <time> will report the GPS information every the
seconds.
Examples
AT+CGPSINFO=?
+CGPSINFO: (0-255)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
372
2017-12-25
Smart Machine Smart Decision
FI
L
17.3
E
OK
AT+CGPSINFO?
+CGPSINFO: 0
OK
AT+CGPSINFO
+CGPSINFO:3113.343286,N,12121.234064,E,250311,072809.3,44.1,0.0,0
OK
AT+CGPSCOLD Cold start GPS
AL
Description
NO
References
Vendor
EN
SIM PIN
TI
This command is used to cold start GPS session.
NOTE: Before using this command,it must use AT+CGPS=0 to stop GPS session.
Responses
OK
Responses
OK
N
FI
Test Command
AT+CGPSCOLD=?
Execution Command
AT+CGPSCOLD
C
M
AT+CGPSCOLD=?
OK
AT+CGPSCOLD
OK
O
Examples
O
AT+CGPSHOT Hot start GPS
C
17.4
D
Syntax
Description
SI
M
This command is used to hot start GPS session
NOTE: Before using this command, AT+CGPS=0 must be used to stop GPS session.
SIM PIN
NO
References
Vendor
Syntax
Test Command
AT+CGPSHOT=?
Responses
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
373
2017-12-25
Smart Machine Smart Decision
Execution Command
AT+CGPSHOT
Responses
OK
Examples
TI
Description
FI
L
AT+CGPSURL Set AGPS default server URL
AL
17.5
E
AT+CGPSHOT=?
OK
AT+CGPSHOT
OK
This command is used to set AGPS default server URL. It will take effect only after restarting.
Vendor
Syntax
D
NO
References
EN
SIM PIN
Responses
OK
Read Command
AT+CGPSURL?
Responses
+CGPSURL: <URL>
OK
Responses
OK
C
Write Command
AT+CGPSURL=<URL>
O
N
FI
Test Command
AT+CGPSURL=?
M
ERROR
O
Defined values
M
C
<URL>
AGPS default server URL. It needs double quotation marks.
SI
Examples
AT+CGPSURL=”123.123.123.123:8888”
OK
AT+CGPSURL?
+CGPSURL: ”123.123.123.123:8888”
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
374
2017-12-25
Smart Machine Smart Decision
17.6
AT+CGPSSSL Set AGPS transport security
Description
SIM PIN
E
This command is used to select transport security, used certificate or not. The certificate gets from
local carrier. If the AGPS server doesn’t need certificate, execute AT+CGPSSSL=0.
References
Vendor
FI
L
NO
AL
Syntax
Responses
+CGPSSSL: (list of supported <SSL>s)
OK
Read Command
AT+CGPSSSL?
Responses
+CGPSSSL: <SSL>
OK
Write Command
Responses
AT+CGPSSSL=<SSL>
OK
EN
D
N
FI
ERROR
TI
Test Command
AT+CGPSSSL=?
O
Defined values
<SSL>
0
1
C
M
Examples
– don’t use certificate
– use certificate
C
O
AT+CGPSSSL=0
OK
AT+CGPSAUTO
Start GPS automatic
M
17.7
SI
Description
This command is used to start GPS automaticly when module powers on, GPS is closed defaultly.
NOTE: If GPS start automatically, its operation mode is standalone mode.
SIM PIN
NO
References
Vendor
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
375
2017-12-25
Smart Machine Smart Decision
Responses
+CGPSAUTO:( list of supported <auto>s)
OK
Read Command
AT+CGPSAUTO?
Responses
+CGPSAUTO:<auto>
OK
Responses
OK
FI
L
Write Command
AT+CGPSAUTO=<auto>
E
Test Command
AT+CGPSAUTO=?
ERROR
<auto>
0
1
AL
Defined values
EN
TI
– Non-automatic
– automatic
Examples
FI
AT+CGPSNMEA Configure NMEA sentence type
N
17.8
D
AT+CGPSAUTO=1
OK
O
Description
M
C
This command is used to configure NMEA output sentences which are generated by the gpsOne
engine when position data is available.
NOTE: If nmea bit 2 GPGSV doesn’t configure, GPGSV sentence also doesn’t output on
AT/modem port even set AT+CGPSFTM=1.
SIM PIN
Vendor
O
NO
References
M
C
Syntax
Responses
+CGPSNMEA: (scope of <nmea>),(scope of <bdnmea>)
OK
Read Command
AT+CGPSNMEA?
Responses
+CGPSNMEA: <nmea>,<bdnmea>
OK
Write Command
Responses
AT+CGPSNMEA=<nmea>[,
OK
SI
Test Command
AT+CGPSNMEA=?
SIM7500_SIM7600 Series_AT Command Manual_V1.07
376
2017-12-25
Smart Machine Smart Decision
If GPS engine is running:
ERROR
<bdnmea>]
Defined values
C
O
N
FI
D
EN
TI
AL
FI
L
E
<nmea>
Range – 0 to 511
Each bit enables an NMEA sentence output as follows:
Bit 0 – GPGGA (global positioning system fix data)
Bit 1 – GPRMC (recommended minimum specific GPS/TRANSIT data)
Bit 2 – GPGSV (GPS satellites in view)
Bit 3 – GPGSA (GPS DOP and active satellites)
Bit 4 – GPVTG (track made good and ground speed)
Bit 5 – PQXFI (Global Positioning System Extended Fix Data.)
Bit 6 – GLGSV (GLONASS satellites in view GLONASS fixes only)
Bit 7 – GNGSA (DOP and GLONASS satellites; GPS+GLONASS or GLONASS-only fixes.
Contains DOP information for all active satellites, but other information is GLONASS-only)
Bit 8 – GNGNS (fix data for GNSS receivers; output for GPS-only, GLONASS-only, hybrid
GLONASS+GPS fixes, or even AFLT fixes)
Set the desired NMEA sentence bit(s). If multiple NMEA sentence formats are desired, “OR” the
desired bits together.
<bdnmea>
Range – 0 to 3
Bit 0 – BDGSA (BEIDOU DOP and active satellites)
Bit 1 – BDGSV (BEIDOU satellites in view)
Examples
C
O
M
AT+CGPSNMEA=511
OK
AT+CGPSNMEA=511,3
OK
AT+CGPSNEMARATE
Set NMEA output rate
M
17.9
SI
Description
This command is used to set nmea output rate
NOTE: send the command before open gps
SIM PIN
NO
References
Vendor
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
377
2017-12-25
Smart Machine Smart Decision
Responses
+ CGPSNMEARATE: (scope of < rate >)
OK
Read Command
AT+CGPSNMEARATE?
Responses
+CGPSNMEARATE: <rate>
OK
Write Command
AT+CGPSNMEARATE=<r
ate>
Responses
OK
FI
L
E
Test Command
AT+CGPSNMEARATE=?
AL
ERROR
Defined values
EN
TI
<rate>
0
output rate 1HZ
1
output rate 10HZ
Examples
FI
D
AT+ CGPSNMEARATE =1
OK
O
N
17.10 AT+CGPSMD Configure AGPS MO method
Description
C
This command specifies if the Mobile-Originated (MO) GPS session should use the control plane
session or user plane session.
NO
Vendor
C
O
Syntax
References
M
SIM PIN
Responses
+CGPSMD: (scope of <method>)
OK
Read Command
AT+CGPSMD?
Responses
+CGPSMD: <method>
OK
Write Command
Responses
AT+CGPSMD=<method>
OK
SI
M
Test Command
AT+CGPSMD=?
If GPS engine is running:
ERROR
SIM7500_SIM7600 Series_AT Command Manual_V1.07
378
2017-12-25
Smart Machine Smart Decision
Defined values
<method>
0 – Control plane
1 – User plane
E
Examples
Start GPS test mode
AL
17.11 AT+CGPSFTM
FI
L
AT+CGPSMD=1
OK
TI
Description
Vendor
C
Syntax
O
NO
References
N
SIM PIN
FI
D
EN
This command is used to start GPS test mode.
NOTE:
1. If test mode starts, the URC will report on AT port, Modem port and UART port.
2. If testing on actual signal, <SV> should be ignored, and GPS must be started by AT+CGPS,
AT+CGPSCOLD or AT+CGPSHOT.
3. If testing on GPS signal simulate equipment, <SV> must be choiced, and GPS will start
automatically.
4. URC sentence will report every 1 second.
Responses
OK
Read Command
AT+CGPSFTM?
Responses
+CGPSFTM: <on/off>
OK
Responses
OK
C
O
M
Test Command
AT+CGPSFTM=?
ERROR
SI
M
Write Command
AT+CGPSFTM=<on/off>
Defined values
<on/off>
0 – Close test mode
1 – Start test mode
<CNo>
Satellite CNo value. Floating value.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
379
2017-12-25
Smart Machine Smart Decision
URC format
$GPGSV[,<SV>,<CNo>][...]
$GLGSV[,<SV>,<CNo>][...]
$BDGSV[,<SV>,<CNo>][...]
E
Examples
FI
L
AT+CGPSFTM=1
OK
$GLGSV,78,20.6,66,25.6,77,21.6,79,21.9,67,26.2,68,23.6
TI
$BDGSV,201,28.7,204,29.0,206,27.3,207,25.9,209,25.0,210,18.5
AL
$GPGSV,10,36.3,12,33.5,14,26.5,15,27.0,18,30.6,20,29.4,21,14.9,24,32.8,25,30.6,31,29.1,32,27.0
EN
17.12 AT+CGPSDEL Delete the GPS information
Description
Vendor
Syntax
M
Test Command
AT+CGPSDEL=?
C
O
NO
References
N
SIM PIN
FI
D
This command is used to delete the GPS information. After executing the command, GPS start is
cold start.
NOTE: This command must be executed after GPS stopped.
Responses
OK
ERROR
C
O
Execution Command
AT+CGPSDEL
Responses
OK
M
Examples
SI
AT+CGPSDEL=?
OK
AT+CGPSDEL
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
380
2017-12-25
Smart Machine Smart Decision
17.13 AT+ CGPSXE
Enable/Disable GPS XTRA function
Description
NO
References
FI
L
SIM PIN
E
This command is used to enable/disable the GPS XTRA function.
NOTE: The function will take effect after restarting the module. XTRA function must download
the assistant file from network by HTTP, so the APN must be set by AT+CGCONT command.
Vendor
AL
Syntax
Responses
+CGPSXE: (list of supported <on/off>s)
OK
Read Command
AT+CGPSXE?
Responses
+CGPSXE: <on/off>
Responses
OK
FI
Write Command
AT+CGPSXE=<on/off>
D
OK
EN
TI
Test Command
AT+CGPSXE=?
N
ERROR
O
Defined values
Examples
M
C
<on/off>
0 – Disable GPS XTRA
1 – Enable GPS XTRA
SI
M
C
O
AT+CGPSXE=?
+CGPSXE: (0,1)
OK
AT+CGPSXE=0
OK
17.14 AT+CGPSXD
Download XTRA assistant file
Description
This command is used to download the GPS XTRA assistant file from network through http
protocol. Module will download the latest assistant file form server and write the file into module.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
381
2017-12-25
Smart Machine Smart Decision
SIM PIN
NO
References
Vendor
Read Command
AT+CGPSXD?
Responses
+CGPSXD: <server>
OK
Write Command
AT+CGPSXD=<server>
Responses
OK
+CGPSXD: <resp>
TI
D
Defined values
EN
+CGPSXD: <resp>
ERROR
FI
L
Responses
+CGPSXD: (list of supported <server>s)
OK
AL
Test Command
AT+CGPSXD=?
E
Syntax
C
O
N
FI
<server>
0 – XTRA primary server (precedence)
1 – XTRA secondary server
2 – XTRA tertiary server
<resp>
refer to Unsolicited XTRA download Codes
Examples
M
C
O
M
AT+CGPSXD=?
+CGPSXD: (0-2)
OK
AT+CGPSXD=0
OK
+CGPSXD: 0
SI
17.15 AT+CGPSXDAUTO Download XTRA assistant file automatically
Description
This command is used to control download assistant file automatically or not when GPS start.
XTRA function must enable for using this command. If assistant file doesn’t exist or check error,
the module will download and inject the assistant file automatically.
SIM PIN
References
SIM7500_SIM7600 Series_AT Command Manual_V1.07
382
2017-12-25
Smart Machine Smart Decision
NO
Vendor
Responses
+CGPSXDAUTO: (list of supported <on/off>s)
OK
Read Command
AT+CGPSXDAUTO?
Responses
+CGPSXDAUTO: <on/off>
OK
Write Command
AT+CGPSXDAUTO=<on/o
ff>
Responses
OK
AL
FI
L
Test Command
AT+CGPSXDAUTO=?
E
Syntax
TI
ERROR
EN
Defined values
M
C
AT+CGPSXDAUTO=?
+CGPSXDAUTO: (0,1)
OK
AT+CGPSXDAUTO=0
OK
O
Examples
N
FI
D
<on/off>
0 – disable download automatically
1 – enable download automatically
NOTE: Some URCs will report when downloading, it’s same as AT+CGPSXD command.
O
17.16 AT+CGPSINFOCFG Report GPS NMEA-0183 sentence
C
Description
M
This command is used to report NMEA-0183 sentence.
SI
SIM PIN
NO
References
Vendor
Syntax
Test Command
AT+CGPSINFOCFG=?
Responses
+CGPSINFOCFG: (scope of <time>),(scope of <config>),(scope of
<bdconfig>)
SIM7500_SIM7600 Series_AT Command Manual_V1.07
383
2017-12-25
Smart Machine Smart Decision
OK
Responses
AT+CGPSINFOCFG?
+CGPSINFOCFG: <time>,<config>,<bdconfig>
OK
Write Command
Responses
AT+CGPSINFOCFG=<time
>[,<config>][,<bdconfig>]
OK
(NMEA-0183 Sentence)
……
FI
L
E
Read Command
AL
OK (if <time>=0)
Defined values
M
C
O
M
C
O
N
FI
D
EN
TI
<time>
The range is 0-255, unit is second, after set <time> will report the GPS NMEA sentence every the
seconds.
If <time>=0, module stop reporting the NMEA sentence.
<config>
Range – 0 to 511
Each bit enables an NMEA sentence output as follows:
Bit 0 – GPGGA (global positioning system fix data)
Bit 1 – GPRMC (recommended minimum specific GPS/TRANSIT data)
Bit 2 – GPGSV (GPS satellites in view)
Bit 3 – GPGSA (GPS DOP and active satellites)
Bit 4 – GPVTG (track made good and ground speed)
Bit 5 –PQXFI (Global Positioning System Extended Fix Data.)
Bit 6 – GLGSV (GLONASS satellites in view GLONASS fixes only)
Bit 7 – GNGSA (DOP and GLONASS satellites; GPS+GLONASS or GLONASS-only fixes.
Contains DOP information for all active satellites, but other information is GLONASS-only)
Bit 8 – GNGNS (fix data for GNSS receivers; output for GPS-only, GLONASS-only, hybrid
GLONASS+GPS fixes, or even AFLT fixes)
Set the desired NMEA sentence bit(s). If multiple NMEA sentence formats are desired, “OR” the
desired bits together.
SI
For example:
If want to report GPRMC sentence by 10 seconds, should execute AT+CGPSINFOCFG=10,2
<bdnmea>
Range – 0 to 3
Bit 0 – BDGSA (BEIDOU DOP and active satellites)
Bit 1 – BDGSV (BEIDOU satellites in view)
Examples
SIM7500_SIM7600 Series_AT Command Manual_V1.07
384
2017-12-25
FI
L
Configure positioning mode
EN
17.17 AT+CGPSPMD
TI
AL
AT+CGPSINFOCFG=?
+CGPSINFO: (0-255),(0-511),(0-3)
OK
AT+CGPSINFOCFG=10,31
OK
$GPGSV,4,1,16,04,53,057,44,02,55,334,44,10,61,023,44,05,45,253,43*7D
$GPGSV,4,2,16,25,10,300,40,17,25,147,40,12,22,271,38,13,28,053,38*77
$GPGSV,4,3,16,26,09,187,35,23,06,036,34,24,,,,27,,,*7A
$GPGSV,4,4,16,09,,,,31,,,,30,,,,29,,,*7D
$GPGGA,051147.0,3113.320991,N,12121.248076,E,1,10,0.8,47.5,M,0,M,,*45
$GPVTG,NaN,T,,M,0.0,N,0.0,K,A*42
$GPRMC,051147.0,A,3113.320991,N,12121.248076,E,0.0,0.0,211211,,,A*66
$GPGSA,A,3,02,04,05,10,12,13,17,23,25,26,,,1.4,0.8,1.2*3B
E
Smart Machine Smart Decision
Description
Vendor
N
NO
References
FI
SIM PIN
D
This command is used to configure the positioning modes support.
NOTE: Need to restart the module after setting the mode.
O
M
Read Command
AT+CGPSPMD?
C
Write Command
AT+CGPSPMD=<mode>
Responses
+CGPSPMD: <mode>
OK
Responses
OK
ERROR
SI
M
Responses
+CGPSPMD: (scope of <mode>)
OK
C
Test Command
AT+CGPSPMD=?
O
Syntax
Defined values
<mode>
Default is 0xFF7F
Each bit enables a supported positioning mode as follows:
Bit 0 – Standalone
Bit 1 – UP MS-based
SIM7500_SIM7600 Series_AT Command Manual_V1.07
385
2017-12-25
Smart Machine Smart Decision
AL
FI
L
E
Bit 2 – UP MS-assisted
Bit 3 – CP MS-based (2G)
Bit 4 – CP MS-assisted (2G)
Bit 5 – CP UE-based (3G)
Bit 6 – CP UE-assisted (3G)
Bit 7 – NOT USED
Bit 8 – UP MS-based (4G)
Bit 9 – UP MS-assisted(4G)
Bit 10 – CP MS-based (4G)
Bit 11 – CP MS-assisted (4G)
Set the desired mode sentence bit(s). If multiple modes are desired, “OR” the desired bits together.
Example, support standalone, UP MS-based and UP MS-assisted, set Binary value 0000 0111, is 7.
TI
Examples
Configure based mode switch to standalone
D
17.18 AT+CGPSMSB
EN
AT+CGPSPMD=127
OK
FI
Description
Vendor
C
NO
References
O
SIM PIN
N
This command is used to configure AGPS based mode switching to standalone mode automatically
or not.
Syntax
O
M
Test Command
AT+CGPSMSB=?
M
C
Read Command
AT+CGPSMSB?
SI
Write Command
AT+CGPSMSB=<mode>
Responses
+CGPSMSB: (scope of <mode>)
OK
Responses
+CGPSMSB: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
0 – Don’t switch to standalone mode automatically
SIM7500_SIM7600 Series_AT Command Manual_V1.07
386
2017-12-25
Smart Machine Smart Decision
1
– Switch to standalone mode automatically
Examples
Configure positioning desired accuracy
FI
L
17.19 AT+CGPSHOR
E
AT+CGPSMSB=0
OK
Description
SIM PIN
References
Vendor
TI
NO
AL
The command is used to configure the positioning desired accuracy threshold in meters.
EN
Syntax
Responses
+CGPSHOR: (scope of <acc>), (scope of < acc_f >)
OK
Read Command
AT+CGPSHOR?
Responses
+CGPSHOR: <acc>,<acc_f>
OK
Write Command
AT+CGPSHOR=<acc>[,<ac
c_f>]
Responses
OK
C
O
N
FI
D
Test Command
AT+CGPSHOR=?
ERROR
M
Defined values
M
C
O
<acc>
Range – 0 to 1800000
Default value is 50
<acc_f>
Reserved
SI
Examples
AT+CGPSHOR=50
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
387
2017-12-25
Smart Machine Smart Decision
17.20 AT+CGPSNOTIFY LCS respond positioning request
Description
This command is used to respond to the incoming request for positioning request message.
Vendor
FI
L
NO
References
E
SIM PIN
Syntax
Responses
AT+CGPSNOTIFY=?
+CGPSNOTIFY: (list of supported <resp>s)
OK
Write Command
AT+CGPSNOTIFY=<resp>
Responses
OK
EN
TI
AL
Test Command
ERROR
FI
N
LCS notify verify accept
LCS notify verify deny
LCS notify verify no response
O
<resp>
0 –
1 –
2 –
D
Defined values
C
Examples
C
O
M
AT+CGPSNOTIFY=?
+CGPSNOTIFY: (0-2)
OK
AT+CGPSNOTIFY=0
OK
AT+CGPSMODE Configure GPS and GLONASS mode
SI
M
17.21
Description
This command is used to configure GPS and GLONASS start mode, so if you configured by this
command, you should reboot the device.
SIM PIN
NO
References
Vendor
SIM7500_SIM7600 Series_AT Command Manual_V1.07
388
2017-12-25
Smart Machine Smart Decision
Syntax
Responses
+CGPSMODE: (scope of <mode>)
OK
Read Command
AT+CGPSMODE?
Responses
+CGPSMODE: <mode>
OK
Write Command
AT+CGPSMODE=<mode>
Responses
OK
FI
L
E
Test Command
AT+CGPSMODE=?
AL
ERROR
TI
Defined values
D
EN
<mode>
0 – GPS and GLONASS hybrid, DPO is enabled, when position fixed, GLONASS will be closed
1 – GPS only
2 – GPS and GLONASS hybrid,DPO is disabled
Default value is 0
FI
Examples
O
AT+CBDS Enable/Disable BEIDOU session
C
17.22
N
AT+CGPSMODE=0
OK
Description
M
This command is used to enable or disable BEIDOU session.
It will take effect only after restarting.
References
O
SIM PIN
Vendor
M
C
NO
SI
Syntax
Test Command
AT+CBDS=?
Responses
+CBDS: (scope of <mode>)
OK
Read Command
AT+CBDS?
Responses
+CBDS: <mode>
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
389
2017-12-25
Smart Machine Smart Decision
Write Command
Responses
AT+CBDS=<mode>
OK
ERROR
E
Defined values
FI
L
<mode>
0 – disable BEIDOU session
1 – enable BEIDOU session
AL
Examples
Get GNSS fixed position information
EN
17.23 AT+CGNSSINFO
TI
AT+CBDS=0
OK
Description
Vendor
N
NO
References
FI
SIM PIN
D
This command is used to get current position related information.
Responses
+CGNSSINFO: (scope of <time>)
OK
C
Test Command
AT+CGNSSINFO=?
O
Syntax
Responses
AT+CGNSSINFO?
+CGNSSINFO: <time>
OK
O
M
Read Command
SI
M
C
Write Command
AT+CGNSSINFO=<time>
Execution Command
AT+CGNSSINFO
Responses
OK
+CGNSSINFO:
[<mode>],[<GPS-SVs>],[<GLONASS-SVs>],[BEIDOU-SVs],
[<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC-time>],[<alt>],
[<speed>],[<course>],[<PDOP>],[HDOP],[VDOP]
OK (if <time>=0)
Responses
+CGNSSINFO:
[<mode>],[<GPS-SVs>],[<GLONASS-SVs>],[BEIDOU-SVs],
SIM7500_SIM7600 Series_AT Command Manual_V1.07
390
2017-12-25
Smart Machine Smart Decision
[<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC-time>],[<alt>],
[<speed>],[<course>],[<PDOP>],[HDOP],[VDOP]
OK
Defined values
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
<mode>
Fix mode 2=2D fix 3=3D fix
<GPS-SVs>
GPS satellite valid numbers
scope: 00-12
< GLONASS-SVs >
GLONASS satellite valid numbers
scope: 00-12
<BEIDU-SVs>
BEIDOU satellite valid numbers
scope: 00-12
<lat>
Latitude of current position. Output format is ddmm.mmmmmm
<N/S>
N/S Indicator, N=north or S=south
<log>
Longitude of current position. Output format is dddmm.mmmmmm
<E/W>
E/W Indicator, E=east or W=west
<date>
Date. Output format is ddmmyy
<UTC time>
UTC Time. Output format is hhmmss.s
<alt>
MSL Altitude. Unit is meters.
<speed>
Speed Over Ground. Unit is knots.
<course>
Course. Degrees.
<time>
The range is 0-255, unit is second, after set <time> will report the GPS information every the
seconds.
<PDOP>
Position Dilution Of Precision.
<HDOP>
Horizontal Dilution Of Precision.
<VDOP>
Vertical Dilution Of Precision.
Examples
SIM7500_SIM7600 Series_AT Command Manual_V1.07
391
2017-12-25
TI
AL
FI
L
AT+CGNSSINFO=?
+CGNSSINFO: (0-255)
OK
AT+CGNSSINFO?
+CGPSINFO: 0
OK
AT+CGNSSINFO
+CGNSSINFO:
2,09,05,00,3113.330650,N,12121.262554,E,131117,091918.0,32.9,0.0,255.0,1.1,0.8,0.7
OK
AT+CGNSSINFO (if not fix,will report null)
+CGNSSINFO: ,,,,,,,,,,,,,,,
OK
E
Smart Machine Smart Decision
EN
17.24 Unsolicited XTRA download Codes
FI
N
O
HTTP timeout
Failed to transfer data
Memory error
Invalid parameter
Network error
M
C
223
224
225
226
227
Description
Assistant file download successfully
Assistant file doesn’t exist
Assistant file check error
Unknown error for HTTP
HTTP task is busy
Failed to resolve server address
D
Code of <err>
0
1
2
220
221
222
AT+CLBS Base station location
M
C
17.25
O
220~227 codes are same as Unsolicited HTTP codes
Description
SI
The write command is used to base station location.
NOTE:
1. The LBS is only support in GSM/WCDMA/CDMA/LTE net mode.
2. It needs to execute AT+CNETSTART to open network before execute the AT+CLBS write
command. It needs to execute AT+CNETSTOP to close network after complete the LBS operation.
SIM PIN
YES
References
3GPP TS 27.007
SIM7500_SIM7600 Series_AT Command Manual_V1.07
392
2017-12-25
Smart Machine Smart Decision
Syntax
Responses
+CLBS:
(1,2,3,4,9),(1-24,100-179),(-180.000000-180.000000),(-90.00000090.000000),(0,1)
E
Test Command
AT+CLBS=?
Responses
OK
AL
1)type = 1,get longitude and latitude
+CLBS: <ret_code>[,<longitude>,<latitude>,<acc>]
TI
Write Command
AT+CLBS=<type>[,<cid>[,
[<longitude>,<latitude>],[<l
on_type>]]]
FI
L
OK
EN
2)type = 2,get detail address
+CLBS: <ret_code>[,<detail_addr>]
D
3)type = 3,get access times
+CLBS: <ret_code>[,<times>]
O
N
FI
4)type = 4,get longitude latitude and date time
+CLBS:
<ret_code>[,<longitude>,<latitude>,<acc>,<date>,<time>]
C
5)type = 9, report positioning error
+CLBS: <ret_code>
ERROR
ERROR
O
M
+CLBS: <ret_code>
C
Defined values
SI
M
<type>
A numeric parameter which specifies the location type.
1 use 3 cell’s information
2 get detail address
3 get access times
4 get longitude latitude and date time
9 report positioning error
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT
command).
SIM7500_SIM7600 Series_AT Command Manual_V1.07
393
2017-12-25
Smart Machine Smart Decision
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
1…24,100…179
<longitude>
Current longitude in degrees.
<latitude>
Current latitude in degrees.
<detail_addr>
Current detail address. It based the UCS2 coding. Each 4 characters in the URC is for one
UCS2 character.
<acc>
Positioning accuracy.
<lon_type>
The type of longitude and latitude
0 WGS84,the default type
1 GCJ02.
<times>
access service times.
<data>
service date(UTC, the format is YYYY/MM/DD,HH:MM:SS).
<time>
service time(UTC, the format is YYYY/MM/DD,HH:MM:SS).
<ret_code>
The result code.
0
Success
1 Parameter error returned by server.
2 Service out of time returned by server.
3 Location failed returned by server.
4 Query timeout returned by server.
5 Certification failed returned by server.
6 Server LBS error success.
7 Server LBS error failed.
80 Report LBS to server success
81 Report LBS to server parameter error
82 Report LBS to server failed
110 Other Error
8
9
10
11
12
13
14
15
LBS is busy.
Open network error.
Close network error.
Operation timeout.
DNS error.
Create socket error.
Connect socket error.
Close socket error.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
394
2017-12-25
Smart Machine Smart Decision
Get cell info error.
Get IMEI error.
Send data error.
Receive data error.
NONET error.
Net not opened.
E
16
17
18
19
20
21
FI
L
Examples
AL
AT+CLBS=?
+CLBS: (1,2,3,4,9),(1-16),(-180.000000-180.000000),(-90.000000-90.000000),(0,1)
TI
OK
AT+CLBS=1
OK
D
EN
+CLBS: 0,31.228525,121.380295,500
AT+CLBS=2
OK
C
+CLBS: 0,22
AT+CLBS=4
OK
O
N
FI
+CLBS:
0,
4e0a6d775e020020957f5b81533a002091d1949f8def002097608fd166688baf79d162805927697c
AT+CLBS=3
OK
C
O
M
+CLBS: 0,31.228525,121.380295,500,2025/06/07,10:49:08
AT+CLBS=9
OK
M
+CLBS: 80
SI
17.26 AT+CLBSCFG Base station location configure
Description
The write command is used to set and query the base station location configure.
SIM PIN
YES
References
3GPP TS 27.007
SIM7500_SIM7600 Series_AT Command Manual_V1.07
395
2017-12-25
Smart Machine Smart Decision
Syntax
Test Command
Responses
AT+CLBSCFG=?
+CLBSCFG: (0-1), (1-3),”Param Value”
Responses
AT+CLBSCFG=<operate>,<
para>[,<value>]
+CLBSCFG: 0,<para>,<value>
FI
L
Write Command
E
OK
OK
ERROR
EN
TI
If error is related to ME functionality:
+CME ERROR: <err>
AL
OK
Defined values
O
M
C
O
N
FI
D
<operate>
A numeric parameter which specifies the operator.
0 read operator
1 write operator
<para>
A numeric parameter which specifies the operator parameter.
1 customer ID
2 Times have used positioning command
3 Server’s address
lbs-simcom.com:3002
<value>
The value of parameter.
If <operate> is 1 and <para> is 1 or 3, <value> can be set.
SI
M
C
Note:
1. When <operate> is 1 and <para> is 1, the length range of <value> is 1 to 20.
2. When <operate> is 1 and <para> is 3, the allowed <value> is "lbs-simcom.com:3002".
Server’s address of "lbs-simcom.com:3002" is free.
Examples
AT+CLBSCFG=?
+CLBSCFG: (0-1),(1-3),"Param Value"
OK
AT+CLBSCFG=0,1
SIM7500_SIM7600 Series_AT Command Manual_V1.07
396
2017-12-25
Smart Machine Smart Decision
+CLBSCFG: 0,1,""
E
OK
AT+CLBSCFG=0,2
+CLBSCFG: 0,2,0
FI
L
OK
AT+CLBSCFG=0,3
+CLBSCFG: 0,3,"lbs-simcom.com:3002"
TI
AL
OK
AT+CLBSCFG=1,3,”lbs-simcom.com:3002”
OK
EN
17.27 AT+CASSISTLOC Base station location of LTE/CDMA1x mode
Description
3GPP TS 27.007
N
YES
References
FI
SIM PIN
D
The write command is used to base station location.This command only be applicable to
telecommunication CDMA and LTE hybrid network or CDMA and EVDO hybrid network.
O
Syntax
Responses
+CASSISTLOC: <longitude>,<latitude>,,
+CASSISTLOC: <ret_code>
OK
ERROR
C
O
M
C
Write Command
AT+CASSISTLOC=<mode>
M
Defined values
SI
<mode>
1 – get longitude and latitude.
<longitude>
Current east longitude in degrees.
<latitude>
Current north latitude in degrees.
<ret_code>
The result code.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
397
2017-12-25
Smart Machine Smart Decision
0
Success
Examples
E
AT+CASSISTLOC=1
+CASSISTLOC:31.220278,121.353058,,
FI
L
+CASSISTLOC:0
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
398
2017-12-25
Smart Machine Smart Decision
AT+CREC
record wav audio file
FI
L
18.1
E
18 Audio Application Commands
Description
SIM PIN
References
Vendor
TI
NO
AL
This command is used to record a wav audio file. It can record wav file during a call or not, the
record file should be put into the “E:/”.
Responses
+CREC: <status>
OK
Write Command
AT+CREC=<record_path>,<filenam
e>
Responses
+CREC:1
OK
AT+CREC=<mode>
+CREC:0
OK
N
O
C
Defined values
D
Read Command
AT+CREC?
FI
EN
Syntax
SI
M
C
O
M
<file_name>
The name of wav audio file.
< record _path>
1 – local path
2 – remote path
<status>
0 – free
1 – busy
<mode>
0 – stop record
Examples
AT+CREC=1,” E:/record.wav”
+CREC: 1
SIM7500_SIM7600 Series_AT Command Manual_V1.07
399
2017-12-25
Smart Machine Smart Decision
AT+CCMXPLAYWAV
Play wav audio file
Description
FI
L
18.2
E
OK
AT+CREC=0
+CREC: 0
OK
AL
This command is used to play a wav audio file. It can play wav file during a call or not.
NOTE Wav file format require mono channel, 8kHz sampling frequency, 16bit sampling size,
SIM PIN
References
Vendor
EN
NO
TI
128kbps.
FI
Responses
+CCMXPLAYWAV: (list of supported <play_path>s),(list of
supported <repeat>s)
N
Test Command
AT+CCMXPLAYWAV=?
D
Syntax
Responses
+WAVSTATE: wav play
OK
Report URC automatically after playing end
+WAVSTATE: wav play stop
ERROR
M
C
O
M
C
Write Command
AT+CCMXPLAYWAV=
<file_name>,<play_path>
O
OK
Defined values
SI
<file_name>
The name of wav audio file.
<play_path>
1 – remote path
2 – local path
<repeat>
This parameter is reserved.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
400
2017-12-25
Smart Machine Smart Decision
Examples
AT+CCMXSTOPWAV
Stop playing wav audio file
FI
L
18.3
E
AT+CCMXPLAYWAV=”E:/record.wav”,2
+WAVSTATE: wav play
OK
Description
SIM PIN
AL
This command is used to stop playing wav audio file. Execute this command during wav audio
playing.
References
TI
Vendor
EN
NO
Syntax
Responses
OK
Execution Command
AT+CCMXSTOPWAV
Responses
[+WAVSTATE: wav play stop]
OK
O
N
FI
D
Test Command
AT+CCMXSTOPWAV=?
AT+ CCMXPLAY Play audio file
C
18.4
O
M
AT+CCMXSTOPWAV
+CCMXSTOPWAV:
OK
C
Examples
M
Description
SI
The command is used to play an audio file.
SIM PIN
NO
References
Vendor
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
401
2017-12-25
Smart Machine Smart Decision
Test Command
AT+CCMXPLAY=?
Responses
+CCMXPLAY: (list of supported <play_path>s),(list of supported
<repeat>s)
OK
E
Responses
+AUDIOSTATE: audio play
FI
L
Write Command
AT+CCMXPLAY=
<file_name>[,<play_path>[,
<repeat>]]
OK
AL
ERROR
Defined values
FI
D
EN
TI
<file_name>
The name of audio file. Support audio file format midi, mp3, aac, amr, qcp, wav.
<play_path>
0 – local path
<repeat>
0 – don’t play repeat. Play only once.
1…255 – play repeat times. E.g. <repeat>=1, audio will play twice.
N
Examples
C
O
at+ccmxplay="E:/ring.mp3",0,255
+ CCMXPLAY:
OK
AT+ CCMXSTOP Stop playing audio file
M
18.5
O
Description
C
The command is used to stop playing audio file. Execute this command during audio playing.
M
SIM PIN
Vendor
SI
NO
References
Syntax
Execution Command
AT+CCMXSTOP
Responses
+ CCMXSTOP:
OK
SIM7500_SIM7600 Series_AT Command Manual_V1.07
402
2017-12-25
Smart Machine Smart Decision
Examples
E
AT+CCMXSTOP
+CCMXSTOP:
OK
AL
Numeric (V0 set)
Description
OK
0
Command executed, no errors, Wake up after reset
CONNECT
1
Link established
RING
2
Ring detected
NO CARRIER
3
Link not established or disconnected
ERROR
4
Invalid command or command line too long
NO DIALTONE
6
No dial tone, dialing impossible, wrong mode
BUSY
7
NO ANSWER
8
D
EN
TI
Verbose result code
FI
Remote station busy
N
Connection completion timeout
Response string of AT+CEER
O
19.2
Verbose code and numeric code
SI
M
C
O
M
Number
CS internal cause
0
21
25
27
29
34
35
36
38
29
45
46
47
48
100
C
19.1
FI
L
19 Appendixes
Response string
Phone is offline
No service available
Network release, no reason given
Received incoming call
Client ended call
UIM not present
Access attempt already in progress
Access failure, unknown source
Concur service not supported by network
No response received from network
GPS call ended for user call
SMS call ended for user call
Data call ended for emergency call
Rejected during redirect or handoff
Lower-layer ended call
SIM7500_SIM7600 Series_AT Command Manual_V1.07
403
2017-12-25
Unassigned/unallocated number
No route to destination
Channel unacceptable
Operator determined barring
Normal call clearing
User busy
No user responding
User alerting, no answer
Call rejected
Number changed
Non selected user clearing
Destination out of order
Invalid/incomplete number
Facility rejected
Response to Status Enquiry
Normal, unspecified
No circuit/channel available
Network out of order
Temporary failure
Switching equipment congestion
Access information discarded
Requested circuit/channel not available
Resources unavailable, unspecified
Quality of service unavailable
Requested facility not subscribed
Incoming calls barred within the CUG
Bearer capability not authorized
Bearer capability not available
EN
D
FI
N
O
C
M
O
C
M
SI
FI
L
CS network cause
1
3
6
8
16
17
18
19
21
22
26
27
28
29
30
31
34
38
41
42
43
44
47
49
50
55
57
58
AL
Call origination request failed
Client rejected incoming call
Client rejected setup indication
Network ended call
No funds available
No service available
Full service not available
Maximum packet calls exceeded
Video connection lost
Video call setup failure
Video protocol closed after setup
Video protocol setup failure
Internal error
TI
101
102
103
104
105
106
108
109
301
302
303
304
305
E
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07
404
2017-12-25
Smart Machine Smart Decision
Service/option not available
Bearer service not implemented
ACM >= ACMmax
Requested facility not implemented
Only RDI bearer is available
Service/option not implemented
Invalid transaction identifier value
User not member of CUG
Incompatible destination
Invalid transit network selection
Semantically incorrect message
Invalid mandatory information
Message non-existent/not implemented
Message type not compatible with state
IE non-existent/not implemented
Conditional IE error
Message not compatible with state
Recovery on timer expiry
Protocol error, unspecified
Interworking, unspecified
CS network reject
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
20
21
22
23
32
IMSI unknown in HLR
Illegal MS
IMSI unknown in VLR
IMEI not accepted
Illegal ME
GPRS services not allowed
GPRS & non GPRS services not allowed
MS identity cannot be derived
Implicitly detached
PLMN not allowed
Location Area not allowed
Roaming not allowed
GPRS services not allowed in PLMN
No Suitable Cells In Location Area
MSC temporarily not reachable
Network failure
MAC failure
Synch failure
Congestion
GSM authentication unacceptable
Service option not supported
FI
L
AL
TI
EN
D
FI
N
O
C
M
O
C
M
SI
E
63
65
68
69
70
79
81
87
88
91
95
96
97
98
99
100
101
102
111
117
SIM7500_SIM7600 Series_AT Command Manual_V1.07
405
2017-12-25
M
FI
L
AL
TI
EN
D
FI
N
O
C
O
PS internal cause lookup
0
1
2
3
4
5
6
7
8
9
10
11
SI
Requested service option not subscribed
Service option temporarily out of orde
Call cannot be identified
No PDP context activated
Semantically incorrect message
Invalid mandatory information
Message type non-existent
Message type not compatible with state
Information element non-existent
Message not compatible with state
RR release indication
RR random access failure
RRC release indication
RRC close session indication
RRC open session failure
Low level failure
Low level failure no redial allowed
Invalid SIM
No service
Timer T3230 expired
No cell available
Wrong state
Access class blocked
Abort message received
Other cause
Timer T303 expired
No resources
Release pending
Invalid user data
C
M
33
34
38
40
95
96
97
98
99
101
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
E
Smart Machine Smart Decision
Invalid connection identifier
Invalid NSAPI
Invalid Primary NSAPI
Invalid field
SNDCP failure
RAB setup failure
No GPRS context
PDP establish timeout
PDP activate timeout
PDP modify timeout
PDP inactive max timeout
PDP lowerlayer error
SIM7500_SIM7600 Series_AT Command Manual_V1.07
406
2017-12-25
PS network cause
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
81
95
96
97
98
99
100
101
111
LLC or SNDCP failure
Insufficient resources
Missing or unknown APN
Unknown PDP address or PDP type
User Aauthentication failed
Activation rejected by GGSN
Activation rejected, unspecified
Service option not supported
Requested service option not subscribed
Service option temporarily out of order
NSAPI already used (not sent)
Regular deactivation
QoS not accepted
Network failure
Reactivation required
Feature not supported
Semantic error in the TFT operation
Syntactical error in the TFT operation
Unknown PDP context
PDP context without TFT already activated
Semantic errors in packet filter
Syntactical errors in packet filter
Invalid transaction identifier
Semantically incorrect message
Invalid mandatory information
Message non-existent/not implemented
Message type not compatible with state
IE non-existent/not implemented
Conditional IE error
Message not compatible with state
Protocol error, unspecified
TI
EN
D
FI
N
O
C
M
O
C
M
SI
19.3
FI
L
PDP duplicate
Access technology change
PDP unknown reason
AL
12
13
14
E
Smart Machine Smart Decision
Summary of CME ERROR codes
Description
This result code is similar to the regular ERROR result code. The format of <err> can be either
numeric or verbose string, by setting AT+CMEE command.
SIM7500_SIM7600 Series_AT Command Manual_V1.07
407
2017-12-25
Smart Machine Smart Decision
SIM PIN
NO
References
3GPP TS 27.007
Syntax
FI
L
E
+CME ERROR: <err>
TI
SI
M
C
O
M
C
O
N
FI
D
EN
<err>
Values (numeric format followed by verbose format):
0
phone failure
1
no connection to phone
2
phone adaptor link reserved
3
operation not allowed
4
operation not supported
5
PH-SIM PIN required
6
PH-FSIM PIN required
7
PH-FSIM PUK required
10
SIM not inserted
11
SIM PIN required
12
SIM PUK required
13
SIM failure
14
SIM busy
15
SIM wrong
16
incorrect password
17
SIM PIN2 required
18
SIM PUK2 required
20
memory full
21
invalid index
22
not found
23
memory failure
24
text string too long
25
invalid characters in text string
26
dial string too long
27
invalid characters in dial string
30
no network service
31
network timeout
32
network not allowed - emergency calls only
40
network personalization PIN required
41
network personalization PUK required
42
network subset personalization PIN required
43
network subset personalization PUK required
AL
Defined values
SIM7500_SIM7600 Series_AT Command Manual_V1.07
408
2017-12-25
FI
L
AL
TI
SI
M
C
O
M
C
O
N
FI
D
EN
44
service provider personalization PIN required
45
service provider personalization PUK required
46
corporate personalization PIN required
47
corporate personalization PUK required
100
Unknown
103
Illegal MESSAGE
106
Illegal ME
107
GPRS services not allowed
111
PLMN not allowed
112
Location area not allowed
113
Roaming not allowed in this location area
132
service option not supported
133
requested service option not subscribed
134
service option temporarily out of order
148
unspecified GPRS error
149
PDP authentication failure
150
invalid mobile class
257
network rejected request
258
retry operation
259
invalid deflected to number
260
deflected to own number
261
unknown subscriber
262
service not available
263
unknown class specified
264
unknown network message
273
minimum TFTS per PDP address violated
274
TFT precedence index not unique
275
invalid parameter combination
“CME ERROR” codes of MMS:
170
Unknown error for mms
171
MMS task is busy now
172
The mms data is over size
173
The operation is overtime
174
There is no mms receiver
175
The storage for address is full
176
Not find the address
177
Invalid parameter
178
Failed to read mss
179
There is not a mms push message
180
Memory error
181
Invalid file format
182
The mms storage is full
183
The box is empty
E
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07
409
2017-12-25
FI
L
AL
TI
EN
O
N
FI
D
184
Failed to save mms
185
It’s busy editing mms now
186
It’s not allowed to edit now
187
No content in the buffer
188
Failed to receive mms
189
Invalid mms pdu
190
Network error
191
Failed to read file
192
None
“CME ERROR” codes of FTP:
201
Unknown error for FTP
202
FTP task is busy
203
Failed to resolve server address
204
FTP timeout
205
Failed to read file
206
Failed to write file
207
It’s not allowed in current state
208
Failed to login
209
Failed to logout
210
Failed to transfer data
211
FTP command rejected by server
212
Memory error
213
Invalid parameter
214
Network error
E
Smart Machine Smart Decision
C
Examples
Summary of CMS ERROR codes
O
19.4
M
AT+CPIN="1234","1234"
+CME ERROR: incorrect password
C
Description
SI
M
Final result code +CMS ERROR: <err> indicates an error related to mobile equipment or network.
The operation is similar to ERROR result code. None of the following commands in the same
command line is executed. Neither ERROR nor OK result code shall be returned. ERROR is
returned normally when error is related to syntax or invalid parameters. The format of <err> can be
either numeric or verbose. This is set with command AT+CMEE.
SIM PIN
---
References
3GPP TS 27.005
Syntax
SIM7500_SIM7600 Series_AT Command Manual_V1.07
410
2017-12-25
Smart Machine Smart Decision
+CMS ERROR: <err>
FI
L
AL
TI
EN
D
M
C
O
N
FI
ME failure
SMS service of ME reserved
Operation not allowed
Operation not supported
Invalid PDU mode parameter
Invalid text mode parameter
SIM not inserted
SIM PIN required
PH-SIM PIN required
SIM failure
SIM busy
SIM wrong
SIM PUK required
SIM PIN2 required
SIM PUK2 required
Memory failure
Invalid memory index
Memory full
SMSC address unknown
no network service
Network timeout
NO +CNMA ACK EXPECTED
Buffer overflow
SMS size more than expected
unknown error
O
<err>
300
301
302
303
304
305
310
311
312
313
314
315
316
317
318
320
321
322
330
331
332
340
341
342
500
E
Defined values
C
Examples
SI
M
AT+CMGS=02112345678
+CMS ERROR: 304
SIM7500_SIM7600 Series_AT Command Manual_V1.07
411
2017-12-25
Smart Machine Smart Decision
Contact us:
Shanghai SIMCom Wireless Solutions Ltd.
SI
M
C
O
M
C
O
N
FI
D
EN
TI
AL
FI
L
E
Add: Building A, SIM Technology Building, No.633, Jinzhong Road, Changning District
200335
Tel: 86-21-32523300
Fax: 86-21-32523020
Email: [email protected]
Website: www.simcomm2m.com
SIM7500_SIM7600 Series_AT Command Manual_V1.07
412
2017-12-25
">
/
Download
Bare en venlig påmindelse. Du kan se dokumentet lige her. Men vigtigst af alt har vores AI allerede læst det. Den kan forklare komplekse ting i enkle vendinger, besvare dine spørgsmål på ethvert sprog og hjælpe dig med hurtigt at navigere selv de længste eller mest komplicerede dokumenter.
Annonce