SIMCom SIM5310 Command Manual
SimCom SIM5310 operates in Quad band GSM/GPRS/EDGE and in Dual band UMTS mode. It supports GPRS multi-slot class 12 and EDGE multi-slot class 12. The comprehensive AT command set makes it easy to develop applications. The module provides USB2.0 interface, audio interface,abundant interfaces (UART, GPIO and I2C) and has rich functionalities (e.g. RTC, PWM, ADC and Watchdog). Thanks to the small size of 24243mm, it is very suitable for slim and compact M2M applications.
Advertisement
Advertisement
AT Command Set
SIMCOM_SIM5310_ATC_EN_V2.00
SIM5310 AT Command Set
Document Title: SIM5310 AT Command Set
Version: 2.00
Date:
Status:
Document ID:
2015-10-15
Release
SIMCOM_SIM5310_ATC_EN_V2.00
General Notes
SIMCom offers this information as a service to its customers, to support application and engineering efforts that use the products designed by SIMCom. The information provided is based upon requirements specifically provided to SIMCom by the customers. SIMCom has not undertaken any independent search for additional relevant information, including any information that may be in the customer’s possession.
Furthermore, system validation of this product designed by SIMCom within a larger electronic system remains the responsibility of the customer or the customer’s system integrator. All specifications supplied herein are subject to change.
Copyright
This document contains proprietary technical information which is the property of SIMCom Limited., copying of this document and giving it to others and the using or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. All rights reserved in the event of grant of a patent or the registration of a utility model or design. All specification supplied herein are subject to change without notice at any time.
Copyright © Shanghai SIMCom Wireless Solutions Ltd. 2014
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
V e r s i o n H i s t o r y
This chapter describes modifications and improvements base on SIMCOM_SIM5310_ATC_EN_V1.02.
Version Chapter Comments
V2.00 New Version
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
C o n t e n t s
........................................................................................................................... 2
............................................................................................................................................ 3
1 Introduction.................................................................................................................................... 15
2 AT Interface Synopsis.................................................................................................................... 18
3 AT Commands According V.25TER.............................................................................................. 20
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4 AT Commands for Status Control.................................................................................................. 49
5 AT Commands for Network........................................................................................................... 77
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
6 AT Commands for Call Control................................................................................................... 126
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
7 AT Commands for SMS............................................................................................................... 161
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
8 AT Commands for Phonebook..................................................................................................... 205
9 AT Commands for GPRS............................................................................................................. 213
10 AT Commands for SIM Application Toolkit............................................................................ 243
11 AT Commands for Audio ......................................................................................................... 250
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
12 AT Commands for Hardware ................................................................................................... 273
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
13 AT Commands for File System................................................................................................ 312
14 AT Commands for File Transmission ...................................................................................... 323
15 AT Commands for MMS.......................................................................................................... 329
AT+CMMSVIEW View the information of MMS from the inbox or the memory ......................... 343
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16 AT Commands for Internet Service ......................................................................................... 356
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
17 AT Commands for Multimedia ................................................................................................ 496
18 AT Commands for LUA Script ................................................................................................ 498
19 AT Commands Samples ........................................................................................................... 506
20 Appendixes .............................................................................................................................. 516
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
........................................................................................................................................... 525
SIM5310_ATC_V2.00 10/15/2015
1 Introduction
1.1
Scope
The present document describes the AT Command Set for the SIMCom Module:
SIM5310
More information about the SIMCom Module which includes the Software Version information can be
. In this document, a short description, the syntax, the possible setting values and responses, and some examples of AT commands are presented.
Prior to using the Module, please read this document and the Version History to know the difference
from the previous document.
In order to implement communication successfully between Customer Application and the Module, it is recommended to use the AT commands in this document, but not to use some commands which are not included in this document.
1.2
References
The present document is based on the following standards:
[1] ETSI GSM 01.04: Abbreviations and acronyms.
[2] 3GPP TS 27.005: Use of Data Terminal Equipment – Data Circuit terminating Equipment (DTE –
DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS).
[3] 3GPP TS 27.007: AT command set for User Equipment (UE).
[4] WAP-224-WTP-20010710-a
[5] WAP-230-WSP-20010705-a
[6] WAP-209-MMSEncapsulation-20010601-a
1.3
Terms and abbreviations
For the purposes of the present document, the following abbreviations apply:
AT from TE/DTE to TA/DCE
CSD Circuit Switched Data
DCE Data Communication Equipment; Data Circuit terminating Equipment
DCS Digital Network
DTE Data Equipment
DTMF Dual Multi–Frequency
EDGE Enhanced Data GSM Environment
SIM5310 AT Command Set
EGPRS Enhanced General Packet Radio Service
GPIO General–Purpose
GPRS General Packet Radio Service
GSM Global System for Mobile communications
HSDPA High Speed Downlink Packet Access
HSUPA High Speed Uplink Packet Access
I2C Inter–Integrated
IMEI International Mobile station Equipment Identity
IMSI International Mobile Subscriber Identity
ME Mobile
MO Mobile–Originated
MS Station
MT Mobile–Terminated; Termination
PCS Personal Communication System
PDU Protocol Unit
PIN Personal
PUK Personal Unlock Key
SIM Subscriber Identity Module
SMS Short Message Service
SMS–SC Short Message Service – Service Center
TA Terminal Adaptor; e.g. a data card (equal to DCE)
TE Terminal Equipment; e.g. a computer (equal to DTE)
UE Equipment
UMTS Universal Mobile Telecommunications System
USIM Universal Subscriber Identity Module
WCDMA Wideband Code Division Multiple Access
FTP File Transfer Protocol
HTTP Hyper Text Transfer Protocol
POP3 Post Office Protocol Version 3
POP3 client An client that can receive e-mail from POP3 server over TCP session
RTC Real Time Clock
SMTP Simple Mail Transfer Protocol
SMTP client An client that can transfer text-based e-mail to SMTP server over TCP session
URC Unsolicited Result Code
MMS Multimedia message system
1.4
Definitions and conventions
1.
For the purposes of the present document, the following syntactical definitions apply:
<CR> Carriage return character.
<LF> Linefeed
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<…> Name enclosed in angle brackets is a syntactical element. Brackets themselves do not appear in the command line.
[…] Optional subparameter of AT command or an optional part of TA information response is enclosed in square brackets. Brackets themselves do not appear in the command line.
If subparameter is not given, its value equals to its previous value or the recommended default value. underline Underlined defined subparameter value is the recommended default setting or factory setting.
2.
Document conventions:
♦
Display the examples of AT commands with Italic format.
♦
Not display blank-line between command line and responses or inside the responses.
♦
Generally, the characters <CR> and <LF> are intentionally omitted throughout this document.
♦
If command response is ERROR, not list the ERROR response inside command syntax.
NOTE: AT commands and responses in figures may be not following above conventions.
3.
Special marks for commands or parameters:
SIM PIN – Is the command PIN protected?
YES – AT command can be used only when SIM PIN is READY.
NO – AT command can be used when SIM card is absent or SIM PIN validation is pending.
References – Where is the derivation of command?
– 3GPP Technical Specification 127 007.
V.25ter – ITU–T Recommendation V.25ter.
Vendor – This command is supported by SIMCom.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
2 AT Interface Synopsis
2.1
Interface settings
Between Customer Application and the Module, standardized RS–232 interface is used for the communication, and default values for the interface settings as following:
115200bps, 8 bit data, no parity, 1 bit stop, no data stream control.
2.2
AT command syntax
The prefix “AT” or “at” (no case sensitive) must be included at the beginning of each command line
(except
), and the character <CR> is used to finish a command line so as to issue the command line to the Module. It is recommended that a command line only includes a command.
When Customer Application issues a series of AT commands on separate command lines, leave a pause between the preceding and the following command until information responses or result codes are retrieved by Customer Application, for example, “OK” is appeared. This advice avoids too many AT commands are issued at a time without waiting for a response for each command.
In the present document, AT commands are divided into three categories: Basic Command, S Parameter
Command, and Extended Command.
1.
Basic Command
The format of Basic Command is “AT<x><n>” or “AT&<x><n>”, “<x>” is the command name, and
“<n>” is/are the parameter(s) for the basic command, and optional. An example of Basic Command is
“ ATE <n>”, which informs the TA/DCE whether received characters should be echoed back to the TE/DTE according to the value of “ <n> ”; “ <n> ” is optional and a default value will be used if omitted.
2.
S Parameter Command
The format of S Parameter Command is “ ATS <n>=<m>”, “<n>” is the index of the S–register to set, and “<m>” is the value to assign to it. “<m>” is optional; in this case, the format is “ ATS <n>”, and then a default value is assigned.
3.
Extended Command
The Extended Command has several formats, as following table list:
Command Type
Table 2-1: Types of Extended Command
Syntax Comments
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Test Command
Read Command
AT+<NAME>=?
AT+<NAME>?
Test the existence of the command; give some information about the command subparameters.
Check the current values of subparameters.
Write Command AT+<NAME>=<…> Set user-definable subparameter values.
Execution Command AT+<NAME> Read non-variable subparameters determined by internal processes.
NOTE: The character “+” between the prefix “AT” and command name may be replaced by other character. For example, using “#” or “$”instead of “+”.
2.3
Information responses
If the commands included in the command line are supported by the Module and the subparameters are correct if presented, some information responses will be retrieved by from the Module. Otherwise, the
Module will report “ERROR” or “+CME ERROR” or “+CMS ERROR” to Customer Application.
Information responses start and end with <CR><LF>, i.e. the format of information responses is
“<CR><LF><response><CR><LF>”. Inside information responses, there may be one or more <CR><LF>.
Throughout this document, only the responses are presented, and <CR><LF> are intentionally omitted.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3 AT Commands According V.25TER
3.1
A/ Repeat last command
Description
This command is used for implement previous AT command repeatedly (except A/
), and the return value depends on the last AT command. If A/ is issued to the Module firstly after power on, the response “OK” is only returned.
SIM PIN References
NO V.25ter
Syntax
Execution Command
A/
Responses
The response the last AT command return
Examples
AT+GCAP
+GCAP:+CGSM,+FCLASS,+DS
OK
A/
+GCAP:+CGSM,+FCLASS,+DS
OK
3.2
ATD Dial command
Description
This command is used to list characters that may be used in a dialling string for making a call or controlling supplementary services.
NOTE:
1.
Support several “P” or “p” in the DTMF string but the valid auto-sending DTMF after characters
“P” or “p” should not be more than 29.
2.
Auto-sending DTMF after character “P” or “p” should be ASCII character in the set 0-9, *, #.
SIM PIN References
NO V25.ter
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Execution Commands
ATD <n> [ <mgsm> ][ ; ]
Responses
Originate a voice call successfully:
OK
VOICE CALL: BEGIN
Originate a data call successfully:
CONNECT <text>
Originate a call unsuccessfully during command execution:
ERROR
Originate a call unsuccessfully for failed connection recovery:
NO CARRIER
Originate a call unsuccessfully for error related to the MT:
+CME ERROR: <err>
Defined values
<n>
String of dialing digits and optionally V.25ter modifiers dialing digits:
0 1 2 3 4 5 6 7 8 9 * # + A B C
Following V.25ter modifiers are ignored:
, T P ! W @
<mgsm>
String of GSM modifiers:
I Activates CLIR (disables presentation of own phone number to called party) i Deactivates CLIR (enables presentation of own phone number to called party)
G Activate Closed User Group explicit invocation for this call only
g Deactivate Closed User Group explicit invocation for this call only
<;>
The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax calls.
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
Service failure result code string; the string formats please refer +CME ERROR result code and
AT+CMEE command.
Examples
ATD10086;
OK
VOICE CALL:BEGIN
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3.3
ATD><mem><n> Originate call from specified memory
Description
This command is used to originate a call using specified memory and index number.
SIM PIN References
NO V.25ter
Syntax
Execution Commands
ATD> <mem><n> [ ; ]
Responses
Originate a voice call successfully:
OK
VOICE CALL: BEGIN
Originate a data call successfully:
CONNECT <text>
Originate a call unsuccessfully during command execution:
ERROR
Originate a call unsuccessfully for failed connection recovery:
NO CARRIER
Originate a call unsuccessfully for error related to the MT:
+CME ERROR: <err>
Defined values
<mem>
Phonebook storage: (For detailed description of storages see AT+CPBS )
"DC" ME dialed calls list
"MC" ME missed (unanswered received) calls list
"RC" ME received calls list
"SM" SIM phonebook
"ME" UE phonebook
"FD" SIM fixed dialing phonebook
"ON" MSISDN list
"LD" Last number dialed phonebook
"EN" Emergency numbers
<n>
Integer type memory location in the range of locations available in the selected memory, i.e. the index returned by AT+CPBR .
<;>
The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax calls.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
Service failure result code string; the string formats please refer +CME ERROR result code and
AT+CMEE command.
Examples
ATD>SM3;
OK
VOICE CALL: BEGIN
3.4
ATD><n> Originate call from active memory (1)
Description
This command is used to originate a call to specified number.
SIM PIN References
NO V.25ter
Syntax
Execution Commands
ATD> <n> [ ; ]
Responses
Originate a voice call successfully:
OK
VOICE CALL: BEGIN
Originate a data call successfully:
CONNECT <text>
Originate a call unsuccessfully during command execution:
ERROR
Originate a call unsuccessfully for failed connection recovery:
NO CARRIER
Originate a call unsuccessfully for error related to the MT:
+CME ERROR: <err>
Defined values
<n>
Integer type memory location in the range of locations available in the selected memory, i.e. the index number returned by AT+CPBR .
<;>
The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set calls.
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
Service failure result code string; the string formats please refer +CME ERROR result code and
AT+CMEE command.
Examples
ATD>2;
OK
VOICE CALL: BEGIN
3.5
ATD><str> Originate call from active memory (2)
Description
This command is used to originate a call to specified number.
SIM PIN References
NO V.25ter
Syntax
Execution Commands
ATD> <str>[; ]
Responses
Originate a voice call successfully:
OK
VOICE CALL: BEGIN
Originate a data call successfully:
CONNECT <text>
Originate a call unsuccessfully during command execution:
ERROR
Originate a call unsuccessfully for failed connection recovery:
NO CARRIER
Originate a call unsuccessfully for error related to the MT:
+CME ERROR: <err>
Defined values
<str>
String type value, which should equal to an alphanumeric field in at least one phone book entry in the searched memories. <str> formatted as current TE character set specified by AT+CSCS .
<str> must be double quoted.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<;>
The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax calls.
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
Service failure result code string; the string formats please refer +CME ERROR result code and
AT+CMEE command.
Examples
ATD>”Kobe”;
OK
VOICE CALL: BEGIN
3.6
ATA Call answer
Description
This command is used to make remote station to go off-hook, e.g. answer an incoming call. If there is no an incoming call and entering this command to TA, it will be return “ NO CARRIER ” to TA.
SIM PIN References
YES V.25ter
Syntax
Execution Commands
ATA
Responses
For voice call:
OK
VOICE CALL: BEGIN
For data call, and TA switches to data mode:
CONNECT
No connection or no incoming call:
NO CARRIER
Examples
ATA
VOICE CALL: BEGIN
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3.7
ATH Disconnect existing call
Description
This command is used to disconnect existing call. Before using
command to hang up a voice
call, it must set AT+CVHU =0. Otherwise, ATH command will be ignored and “
OK ” response is given only.
This command is also used to disconnect CSD or PS data call, and in this case it doesn’t depend on the value of AT+CVHU .
SIM PIN References
NO V.25ter
Syntax
Execution Command
ATH
Responses
VOICE CALL: END: <time>
OK
OK
Defined values
<time>
Voice call connection time:
Format – HHMMSS (HH: hour, MM: minute, SS: second)
Examples
AT+CVHU=0
OK
ATH
VOICE CALL:END:000017
OK
3.8
ATS0 Automatic answer incoming call
Description
The S-parameter command controls the automatic answering feature of the Module. If set to 000, automatic answering is disabled, otherwise it causes the Module to answer when the incoming call indication (RING) has occurred the number of times indicated by the specified value; and the setting will not be stored upon power-off, i.e. the default value will be restored after restart.
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
YES V.25ter
Syntax
Read Command
ATS0?
Write Command
ATS0= <n>
Responses
<n>
OK
Responses
OK
Defined values
<n>
000 Automatic answering mode is disable. (default value when power-on)
001–255 Enable automatic answering on the ring number specified.
NOTE: 1.The S-parameter command is effective on voice call and data call.
2.If <n> is set too high, the remote party may hang up before the call can be answered automatically.
Examples
ATS0?
000
OK
ATS0=003
OK
3.9
+++ Switch from data mode to command mode
Description
This command is only available during a connecting CSD call or PS data call. The +++ character
sequence causes the TA to cancel the data flow over the AT interface and switch to Command
Mode. This allows to enter AT commands while maintaining the data connection to the remote device.
NOTE:
To prevent the +++ escape sequence from being misinterpreted as data, it must be preceded
and followed by a pause of at least 1000 milliseconds, and the interval between two ‘+’ character can’t exceed 900 milliseconds.
SIM PIN References
YES V.25ter
Syntax
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Execution Command
+++
Responses
OK
Examples
+++
OK
3.10
ATO Switch from command mode to data mode
Description
is the corresponding command to the +++ escape sequence. When there is a CSD call or a PS
data call connected and the TA is in Command Mode,
causes the TA to resume the data and takes back to Data Mode.
SIM PIN References
YES V.25ter
Syntax
Execution Command
ATO
Responses
TA/DCE switches to Data Mode from Command Mode:
CONNECT (baud rate)
If connection is not successfully resumed or there is not a connected CSD call:
NO CARRIER
Examples
ATO
CONNECT 115200
3.11
ATI Display product identification information
Description
This command is used to request the product information, which consists of manufacturer identification, model identification, revision identification, International Mobile station Equipment
Identity (IMEI) and overall capabilities of the product.
SIM PIN References
NO V.25ter
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Execution Command
ATI
Responses
Manufacturer: <manufacturer>
Model: <model>
Revision: <revision>
IMEI: <sn>
+GCAP: list of <name> s
OK
Defined values
<manufacturer>
The identification of manufacturer.
<model>
The identification of model.
<revision>
The revision identification of firmware.
<sn>
Serial number identification, which consists of a single line containing IMEI (International Mobile station Equipment Identity) number.
<name>
List of additional capabilities:
+CGSM GSM function is supported
+FCLASS FAX function is supported
+DS Data compression is supported
+ES Synchronous data mode is supported.
Examples
ATI
Manufacturer: SIMCOM INCORPORATED
Model: SIMCOM_SIM5310
Revision: SIM5310_V1.5
IMEI: 351602000330570
+GCAP: +CGSM,+FCLASS,+DS
OK
3.12
AT+IPR Set local baud rate temporarily
Description
This command sets the baud rate of module’s serial interface temporarily, after reboot the baud rate is set to default value.The default value is 115200.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
NO V.25ter
Syntax
Test Command
AT+IPR=?
Read Command
AT+IPR?
Write Command
AT+IPR= <speed>
Execution Command
AT+IPR
Responses
+IPR: (list of supported <speed> s)
OK
Responses
+IPR: <speed>
OK
Responses
OK
ERROR
Responses
Set default value 115200:
OK
Defined values
<speed>
Baud rate per second:
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800,921600,
3200000,3686400,4000000
Examples
AT+IPR?
+IPR: 115200
OK
AT+IPR=?
+IPR:(300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400,460800,921600,
3200000, 3686400, 4000000)
OK
AT+IPR=115200
OK
3.13
AT+ICF Set control character framing
Description
This command sets character framing which contains data bit, stop bit and parity bit.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
NO Vendor
Syntax
Test Command
AT+ICF=?
Read Command
AT+ICF?
Write Command
AT+ICF=
<format> [, <parity> ]
Execution Command
AT+ICF
Defined values
<format>
Only support value “3” at moment:
3 – data bit 8, stop bit 1
<parity>
0 – Odd
1 – Even
2 – mark
3 – none
Examples
AT+ICF?
+ICF: 3,3
OK
AT+ICF=?
+ICF: (3),(0-3)
OK
AT+ICF=3,3
OK
Responses
+ICF: (list of supported <format> s), (list of supported <parity> s)
OK
Responses
+ICF: <format> , <parity>
OK
Responses
OK
ERROR
Responses
Set default value:
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3.14
AT+IFC Set local data flow control
Description
The command sets the flow control mode of the module.
SIM PIN References
NO V.25ter
Syntax
Test Command
AT+IFC=?
Read Command
AT+IFC?
Write Command
AT+IFC= <DCE> [, <DTE> ]
Execution Command
AT+IFC
Responses
+IFC: (list of supported <DCE> s), (list of supported <DTE> s)
OK
ERROR
Responses
+IFC: <DCE> , <DTE>
OK
ERROR
Responses
OK
ERROR
Responses
Set default value:
OK
ERROR
Defined values
<DCE>
0 – none (default)
1 – software flow control(XON/XOFF) but strip XON/XOFF characters from stream
2 – RTS hardware flow control
3 – software flow control(XON/XOFF) and leave XON/XOFF characters in stream
<DTE>
0 – none (default)
1 – software flow control(XON/XOFF) but strip XON/XOFF characters from stream
2 – CTS hardware flow control
3 – software flow control(XON/XOFF) and leave XON/XOFF characters in stream
Examples
AT+IFC?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+IFC: 0,0
OK
AT+IFC=?
+IFC: (0-3),(0-3)
OK
AT+IFC=2,2
OK
3.15
AT&C Set DCD function mode
Description
This command determines how the state of DCD PIN relates to the detection of received line signal from the distant end.
NOTE: After executing AT+CSUART =1 and AT+CGFUNC =10,1, it takes effect.
SIM PIN References
NO V.25ter
Syntax
Execution Command
AT&C[ <value> ]
Responses
OK
ERROR
Defined values
<value>
0 DCD line shall always be on.
1 DCD line shall be on only when data carrier signal is present.
2 Setting winks(briefly transitions off,then back on)the DCD line when data calls end.
Examples
AT&C1
OK
3.16
ATE Enable command echo
Description
This command sets whether or not the TA echoes characters.
SIM PIN References
NO V.25ter
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Execution Command
ATE[ <value> ]
Responses
OK
ERROR
Defined values
<value>
0 – Echo mode off
1 – Echo mode on
Examples
ATE1
OK
3.17
AT&V Display current configuration
Description
This command returns some of the base configuration parameters settings.
SIM PIN References
YES V.25ter
Syntax
Execution Command
AT&V
Responses
<TEXT>
OK
Defined values
<TEXT>
All relative configuration information.
Examples
AT&V
&C: 0; &D: 2; &F: 0; E: 1; L: 0; M: 0; Q: 0; V: 1; X: 0; Z: 0; S0: 0;
S3: 13; S4: 10; S5: 8; S6: 2; S7: 50; S8: 2; S9: 6; S10: 14; S11: 95;
+FCLASS: 0; +ICF: 3,3; +IFC: 2,2; +IPR: 115200; +DR: 0; +DS: 0,0,2048,6;
+WS46: 12; +CBST: 0,0,1;
……
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
3.18
AT&D Set DTR function mode
Description
This command determines how the TA responds when DTR PIN is changed from the ON t o the OFF condition during data mode.
NOTE: After executing AT+CSUART =1, it takes effect.
SIM PIN References
NO V.25ter
Syntax
Execution Command
AT&D[ <value> ]
Responses
OK
ERROR
Defined values
<value>
0 TA ignores status on DTR.
1 ON->OFF on DTR: Change to Command mode with remaining the connected call
2 ON->OFF on DTR: Disconnect call, change to Command mode.During state DTR =
OFF is auto-answer off.
Examples
AT&D1
OK
3.19
AT&S Set DSR function mode
Description
The command determines how the state of DSR pin works.
SIM PIN References
YES V.25ter
Syntax
Execution Command
AT&S <value>
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
ERROR
Defined values
<value>
0 DSR line shall always be on.
1 DSR line shall be on only when DTE and DCE are connected.
Examples
AT&S0
OK
3.20
ATV Set result code format mode
Description
This parameter setting determines the contents of the header and trailer transmitted with result codes and information responses.
NOTE: In case of using This command without parameter < value > will be set to 0.
SIM PIN References
NO V.25ter
Syntax
Write Command
ATV[ <value> ]
Responses
If <value> =0
0
If <value> =1
OK
Defined values
<value>
0 Information response: <text><CR><LF>
Short result code format: <numeric code><CR>
1 Information response: <CR><LF><text><CR><LF>
Long result code format: <CR><LF><verbose code><CR><LF>
Examples
ATV1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3.21
AT&F Set all current parameters to manufacturer defaults
Description
This command is used to set all current parameters to the manufacturer defined profile.
NOTE: List of parameters reset to manufacturer default can be found in defined values, factory default settings restorable with AT&F[ <value> ].
Every ongoing or incoming call will be terminated.
SIM PIN References
NO V.250
Syntax
Execution Command
AT&F[ <value> ]
Responses
OK
Defined values
<value>
0 — Set some temporary TA parameters to manufacturer defaults. The setting after power on or reset is same as value 0.
1 — Set all TA parameters to manufacturer defaults.
NOTE: Module must reset after setting value 1, otherwise some unknown issue will happen. default values
TA parameters VALUE
AT+CATR 0
AT+CSUART
AT+CPCM
AT+CPCMFMT
AT+CPCMSLOT
AT+CNBP ○
AT+CNMP
AT+CNAOP
AT+CNSDP
AT+CTZU
AT+CRSL
AT+CALM
AT+CEMNLIST
AT+CVALARM
2
0
0
0,0
0x0002000000680380
2
2
2
0
2
0
0, ""
0,3400
AT+CRFEN
AT+CSDVC
1
1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CLVL ○
AT+CVLVL ○
AT+CMICAMP1 ○
AT+SIDET ○
AT+CTXGAIN ○
AT+CRXGAIN ○
AT+CTXVOL ○
AT+CRXVOL ○
AT+CTXFTR ○
AT+CRXFTR ○
AT+CVAUXS
AT+CVAUXV
AT+CDTRISRS
AT+CDTRISRMD
AT+CGDCONT
AT+CGSOCKCONT
AT+CPLMNWLIST
AT+CPASSMGR
AT+CGPSSSL
AT+CGPSURL
AT+CMMSSENDCFG
AT+CMMSCURL
AT+CMMSPROTO
AT+CGPSAUTO
AT+CGPSSWITCH
2
-200,1000,3000,5000,3000,4000,5000,5000
1
8000
10000
3000
10000
0
0, 0, 0, 0, 0, 0, 0
0, 0, 0, 0, 0, 0, 0
1
52
0
0,0
1,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 1,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 2,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 3,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 4,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 5,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 6,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 7,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 8,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 9,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 10,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 11,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 12,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 13,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 14,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 15,"IP","","0.0.0.0",0,0
+CGSOCKCONT: 16,"IP","","0.0.0.0",0,0
"", 1
NULL (disable all passwords )
0
""
6,3,0,0,2,4
""
1,"0.0.0.0",0
0
1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM5320E default value is 0x0002000000680380. SIM5320A default value is
0x000000000CA80380.SIM5320J default value is 0x000000000CE80380.
○ These audio parameters is discrepant in different Qualcomm platform version.
Examples
AT&F
OK
AT&F1
OK (then reset the module manually)
3.22
ATQ Set Result Code Presentation Mode
Description
Specify whether the TA transmits any result code to the TE or not. Text information transmitted in response is not affected by this setting
SIM PIN References
YES 3GPP TS 27.005
Syntax
Write Command
ATQ<n>
Execution Command
ATQ
Responses
If <n>=0:
OK
If <n>=1:
Responses
Set default value:0
OK
Defined values
<n>
0 – DCE transmits result code
1 – DCE not transmits result code
Examples
ATQ0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3.23
ATX Set CONNECT Result Code Format
Description
This parameter setting determines whether the TA transmits unsolicited result codes or not. The unsolicited result codes are
<CONNECT><SPEED><COMMUNICATION PROTOCOL>[<TEXT>]
SIM PIN References
YES 3GPP TS 27.005
Syntax
Write Command
ATX<VALUE>
Execution Command
ATX
Responses
OK
ERROR
Responses
Set default value:1
OK
Defined values
<value>
0 – CONNECT result code returned
1,2,3,4 – May be transmits extern result codes according to AT&E and AT\V settings. Refer to
AT&E.
Examples
ATX1
OK
3.24
AT\V Set CONNECT Result Code Format About Protocol
Description
This parameter setting determines whether report the communication protocol. If PS call, it also determines wether report APN, uplink rate, downlink rate.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Write Command Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT\V<value>
Execution Command
AT\V
OK
ERROR
Responses
Set default value: 0
OK
Defined values
<value>
0 – Don’t report
1 – Report communication protocol. And report APN, uplink rate, downlink rate if PS call.
Refer to AT&E. The maybe communication protocol report include
“NONE”,”PPPoverUD”,”AV32K”,”AV64K”,”PACKET”. And APN in string format while uplink rate and downlink rate in integer format with kb unit.
Examples
AT\V0
OK
3.25
AT&E Set CONNECT Result Code Format About Speed
Description
This parameter setting determines to report Serial connection rate or Wireless connection speed. It is valid only ATX above 0.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Write Command
AT&E<value>
Execution Command
AT&E
Responses
OK
ERROR
Responses
Set default value: 1
OK
Defined values
<value>
0 – Wireless connection speed in integer format.
1 – Serial connection rate in integer format. Such as: “115200”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT&E0
OK
3.26
AT&W Save the user setting to ME
Description
This command will save the user settings to ME which set by ATE, ATQ, ATV, ATX, AT&C AT&D,
AT&S, AT\V, AT+IFC and ATS0.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Write Command
AT&W<value>
Execution Command
AT&W
Responses
OK
ERROR
Responses
Set default value: 0
OK
Defined values
<value>
0 – Save
Examples
AT&W0
OK
3.27
ATZ Restore the user setting from ME
Description
This command will restore the user setting from ME which set by ATE, ATQ, ATV, ATX, AT&C
AT&D, AT&S, AT\Q, AT\V, and ATS0.
SIM PIN References
YES 3GPP TS 27.005
Syntax
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
ATZ<value>
Execution Command
ATZ
Responses
OK
ERROR
Responses
Set default value: 0
OK
Defined values
<value>
0 – Restore
Examples
ATZ0
OK
3.28
AT+CGMI Request manufacturer identification
Description
This command is used to request the manufacturer identification text, which is intended to permit the user of the Module to identify the manufacturer.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CGMI=?
Execution Command
AT+CGMI
Defined values
<manufacturer>
The identification of manufacturer.
Examples
AT+CGMI
SIMCOM INCORPORATED
Responses
OK
Responses
<manufacturer>
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
3.29
AT+CGMM Request model identification
Description
This command is used to requests model identification text, which is intended to permit the user of the Module to identify the specific model.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CGMM=?
Execution Command
AT+CGMM
Responses
OK
Responses
<model>
OK
Defined values
<model>
The identification of model.
Examples
AT+CGMM
SIMCOM_SIM5310
OK
3.30
AT+CGMR Request revision identification
Description
This command is used to request product firmware revision identification text, which is intended to permit the user of the Module to identify the version.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CGMR=?
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Execution Command
AT+CGMR
Responses
+CGMR : <revision>
OK
Defined values
<revision>
The revision identification of firmware.
Examples
AT+CGMR
+CGMR: 1575B03SIM5310
OK
3.31
AT+CGSN Request product serial number identification
Description
This command requests product serial number identification text, which is intended to permit the user of the Module to identify the individual ME to which it is connected to.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CGSN=?
Execution Command
AT+CGSN
Responses
OK
Responses
<sn>
OK
Defined values
<sn>
Serial number identification, which consists of a single line containing the IMEI (International
Mobile station Equipment Identity) number of the MT.
Examples
AT+CGSN
351602000330570
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3.32
AT+CSCS Select TE character set
Description
Write command informs TA which character set <chest> is used by the TE. TA is then able to convert character strings correctly between TE and MT character sets.
Read command shows current setting and test command displays conversion schemes implemented in the TA.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CSCS=?
Read Command
AT+CSCS?
Write Command
AT+CSCS= <chset>
Execution Command
AT+CSCS
Responses
+CSCS: (list of supported <chset> s)
OK
Responses
+CSCS: <chset>
OK
Responses
OK
ERROR
Responses
Set subparameters as default value:
OK
Defined values
<chest>
Character set, the definition as following:
“IRA”
International reference alphabet.
“GSM” GSM default alphabet; this setting causes easily software flow control (XON
/XOFF) problems.
“UCS2” 16-bit universal multiple-octet coded character set; UCS2 character strings
are converted to hexadecimal numbers from 0000 to FFFF.
Examples
AT+CSCS=”IRA”
OK
AT+CSCS?
+CSCS:”IRA”
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3.33
AT+CIMI Request international mobile subscriber identity
Description
Execution command causes the TA to return <IMSI> , which is intended to permit the TE to identify the individual SIM card which is attached to MT.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CIMI=?
Execution Command
AT+CIMI
Responses
OK
Responses
<IMSI>
OK
Defined values
<IMSI>
International Mobile Subscriber Identity (string, without double quotes).
Examples
AT+CIMI
460010222028133
OK
3.34
AT+GCAP Request overall capabilities
Description
Execution command causes the TA reports a list of additional capabilities.
SIM PIN References
YES V.25ter
Syntax
Test Command
AT+GCAP=?
Execution Command
Responses
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+GCAP +GCAP: (list of <name> s)
OK
Defined values
<name>
List of additional capabilities.
+CGSM GSM function is supported
+FCLASS FAX function is supported
+DS Data compression is supported
+ES Synchronous data mode is supported.
Examples
AT+GCAP
+GCAP:+CGSM,+FCLASS,+DS
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4 AT Commands for Status Control
4.1
AT+CFUN Set phone functionality
Description
This command is used to select the level of functionality <fun> in the ME. Level "full functionality" is where the highest level of power is drawn. "Minimum functionality" is where minimum power is drawn. Level of functionality between these may also be specified by manufacturers. When supported by manufacturers, ME resetting with <rst> parameter may be utilized.
NOTE: AT+CFUN =6 must be used after setting AT+CFUN =7. If module in offline mode, must execute AT+CFUN =6 or restart module to online mode.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CFUN=?
Read Command
AT+CFUN?
Write Command
AT+CFUN= <fun> [, <rst> ]
Responses
+CFUN: (list of supported <fun> s), (list of supported <rst> s)
OK
ERROR
+CME ERROR: <err>
Responses
+CFUN: <fun>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<fun>
0 – minimum functionality
1 – full functionality, online mode
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4 – disable phone both transmit and receive RF circuits
5 – Factory Test Mode
6 – Reset
7 – Offline Mode
<rst>
0 – do not reset the ME before setting it to <fun> power level
1 – reset the ME before setting it to <fun> power level. This value only takes effect when
<fun> equals 1.
Examples
AT+CFUN?
+CFUN: 1
OK
AT+CFUN=0
OK
4.2
AT+CPIN Enter PIN
Description
This command is used to send the ME a password which is necessary before it can be operated
(SIM PIN, SIM PUK, PH-SIM PIN, etc.). If the PIN is to be entered twice, the TA shall automatically repeat the PIN. If no PIN request is pending, no action is taken towards MT and an error message, +CME ERROR, is returned to TE.
If the PIN required is SIM PUK or SIM PUK2, the second pin is required. This second pin,
<newpin> , is used to replace the old pin in the SIM.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CPIN=?
Read Command
AT+CPIN?
Write Command
AT+CPIN=
<pin> [, <newpin> ]
Responses
OK
Responses
+CPIN: <code>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CME ERROR: <err>
Defined values
<pin>
String type values.
<newpin>
String type values.
<code>
Values reserved by the present document:
READY – ME is not pending for any password
SIM PIN – ME is waiting SIM PIN to be given
SIM PUK – ME is waiting SIM PUK to be given
PH-SIM PIN – ME is waiting phone-to-SIM card password to be given
SIM PIN2 – ME is waiting SIM PIN2 to be given
SIM PUK2 – ME is waiting SIM PUK2 to be given
PH-NET PIN – ME is waiting network personalization password to be given
Examples
AT+CPIN?
+CPIN: SIM PUK2
OK
4.3
AT+CICCID Read ICCID from SIM card
Description
This command is used to Read the ICCID from SIM card
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CICCID=?
Execution Command
AT+CICCID
Responses
OK
Responses
+ICCID: <ICCID>
OK
ERROR
+CME ERROR: <err>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<ICCID>
Integrate circuit card identity, a standard ICCID is a 20-digit serial number of the SIM card, it presents the publish state, network code, publish area, publish date, publish manufacture and press serial number of the SIM card.
Examples
AT+CICCID
+ICCID: 898600700907A6019125
OK
4.4
AT+CSIM Generic SIM access
Description
This command is used to control the SIM card directly.
Compared to restricted SIM access command AT+CRSM , AT+CSIM allows the ME to take more control over the SIM interface.
For SIM–ME interface please refer 3GPP TS 11.11.
NOTE : The SIM Application Toolkit functionality is not supported by AT+CSIM . Therefore the following SIM commands can not be used: TERMINAL PROFILE , ENVELOPE ,
FETCH and TEMINAL RESPONSE .
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CSIM=?
Write Command
AT+CSIM=
<length> , <command>
Responses
OK
Responses
+CSIM: <length> , <response>
OK
ERROR
+CME ERROR: <err>
Defined values
<length>
Interger type; length of characters that are sent to TE in <command> or <response>
<command>
Command passed from MT to SIM card.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<response>
Response to the command passed from SIM card to MT.
Examples
AT+CSIM=?
OK
4.5
AT+CRSM Restricted SIM access
Description
By using AT+CRSM instead of Generic SIM Access AT+CSIM , TE application has easier but more limited access to the SIM database.
Write command transmits to the MT the SIM <command> and its required parameters. MT handles internally all SIM-MT interface locking and file selection routines. As response to the command,
MT sends the actual SIM information parameters and response data. MT error result code +CME
ERROR may be returned when the command cannot be passed to the SIM, but failure in the execution of the command in the SIM is reported in <sw1> and <sw2> parameters.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CRSM=?
Responses
OK
Write Command
AT+CRSM= <command>
[, <fileID> [, <p1> , <p2> , <p3>
[, <data> ]]]
Responses
+CRSM: <sw1> , <sw2> [, <response> ]
OK
ERROR
+CME ERROR: <err>
Defined values
<command>
Command passed on by the MT to the SIM:
176 – READ BINARY
178 – READ RECORD
192 – GET RESPONSE
214 – UPDATE BINARY
220 – UPDATE RECORD
242 – STATUS
203 – RETRIEVE DATA
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
219 – SET DATA
<fileID>
Identifier for an elementary data file on SIM, if used by <command>.
The following list the fileID hex value, user needs to convet them to decimal.
EFs under MF
0x2FE2 ICCID
0x2F05 Extended Language Preferences
0x2F00 EF DIR
0x2F06 Access Rule Reference
EFs under USIM ADF
0x6F05 Language Indication
0x6F07 IMSI
0x6F08 Ciphering and Integrity keys
0x6F09 C and I keys for pkt switched domain
0x6F60 User controlled PLMN selector w/Acc Tech
0x6F30 User controlled PLMN selector
0x6F31 HPLMN search period
0x6F37 ACM maximum value
0x6F38 USIM Service table
0x6F39 Accumulated Call meter
0x6F3E Group Identifier Level
0x6F3F Group Identifier Level 2
0x6F46 Service Provider Name
0x6F41 Price Per Unit and Currency table
0x6F45 Cell Bcast Msg identifier selection
0x6F78 Access control class
0x6F7B Forbidden PLMNs
0x6F7E Location information
0x6FAD Administrative data
0x6F48 Cell Bcast msg id for data download
0x6FB7 Emergency call codes
0x6F50 Cell bcast msg id range selection
0x6F73 Packet switched location information
0x6F3B Fixed dialling numbers
0x6F3C Short messages
0x6F40 MSISDN
0x6F42 SMS parameters
0x6F43 SMS Status
0x6F49 Service dialling numbers
0x6F4B Extension 2
0x6F4C Extension 3
0x6F47 SMS reports
0x6F80 Incoming call information
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0x6F81 Outgoing call information
0x6F82 Incoming call timer
0x6F83 Outgoing call timer
0x6F4E Extension 5
0x6F4F Capability Config Parameters 2
0x6FB5 Enh Multi Level Precedence and Pri
0x6FB6 Automatic answer for eMLPP service
0x6FC2 Group identity
0x6FC3 Key for hidden phonebook entries
0x6F4D Barred dialling numbers
0x6F55 Extension 4
0x6F58 Comparison Method information
0x6F56 Enabled services table
0x6F57 Access Point Name Control List
0x6F2C De-personalization Control Keys
0x6F32 Co-operative network list
0x6F5B Hyperframe number
0x6F5C Maximum value of Hyperframe number
0x6F61 OPLMN selector with access tech
0x6F5D OPLMN selector
0x6F62 HPLMN selector with access technology
0x6F06 Access Rule reference
0x6F65 RPLMN last used access tech
0x6FC4 Network Parameters
0x6F11 CPHS: Voice Mail Waiting Indicator
0x6F12, CPHS: Service String Table
0x6F13 CPHS: Call Forwarding Flag
0x6F14 CPHS: Operator Name String
0x6F15 CPHS: Customer Service Profile
0x6F16 CPHS: CPHS Information
0x6F17 CPHS: Mailbox Number
0x6FC5 PLMN Network Name
0x6FC6 Operator PLMN List
0x6F9F Dynamic Flags Status
0x6F92 Dynamic2 Flag Setting
0x6F98 Customer Service Profile Line2
0x6F9B EF PARAMS - Welcome Message
0x4F30 Phone book reference file
0x4F22 Phone book synchronization center
0x4F23 Change counter
0x4F24 Previous Unique Identifier
0x4F20 GSM ciphering key Kc
0x4F52 GPRS ciphering key
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0x4F63 CPBCCH information
0x4F64 Investigation scan
0x4F40 MExE Service table
0x4F41 Operator Root Public Key
0x4F42 Administrator Root Public Key
0x4F43 Third party Root public key
0x6FC7 Mail Box Dialing Number
0x6FC8 Extension 6
0x6FC9 Mailbox Identifier
0x6FCA Message Waiting Indication Status
0x6FCD Service Provider Display Information
0x6FD2 UIM_USIM_SPT_TABLE
0x6FD9 Equivalent HPLMN
0x6FCB Call Forwarding Indicator Status
0x6FD6 GBA Bootstrapping parameters
0x6FDA GBA NAF List
0x6FD7 MBMS Service Key
0x6FD8 MBMS User Key
0x6FCE MMS Notification
0x6FD0 MMS Issuer connectivity parameters
0x6FD1 MMS User Preferences
0x6FD2 MMS User connectivity parameters
0x6FCF Extension 8
0x5031 Object Directory File
0x5032 Token Information File
0x5033 Unused space Information File
EFs under Telecom DF
0x6F3A Abbreviated Dialing Numbers
0x6F3B Fixed dialling numbers
0x6F3C Short messages
0x6F3D Capability Configuration Parameters
0x6F4F Extended CCP
0x6F40 MSISDN
0x6F42 SMS parameters
0x6F43 SMS Status
0x6F44 Last number dialled
0x6F49 Service Dialling numbers
0x6F4A Extension 1
0x6F4B Extension 2
0x6F4C Extension 3
0x6F4D Barred Dialing Numbers
0x6F4E Extension 4
0x6F47 SMS reports
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0x6F58 Comparison Method Information
0x6F54 Setup Menu elements
0x6F06 Access Rule reference
0x4F20 Image
0x4F30 Phone book reference file
0x4F22 Phone book synchronization center
0x4F23 Change counter
0x4F24 Previous Unique Identifier
<p1> <p2> <p3>
Integer type; parameters to be passed on by the Module to the SIM.
<data>
Information which shall be written to the SIM (hexadecimal character format, refer AT+CSCS ).
<sw1> <sw2>
Status information from the SIM about the execution of the actual command. It is returned in both cases, on successful or failed execution of the command.
<response>
Response data in case of a successful completion of the previously issued command.
“STATUS” and “GET RESPONSE” commands return data, which gives information about the currently selected elementary data field. This information includes the type of file and its size.
After “READ BINARY” or “READ RECORD” commands the requested data will be returned.
<response> is empty after “UPDATE BINARY” or “UPDATE RECORD” commands.
Examples
AT+CRSM=?
OK
4.6
AT+SPIC Times remain to input SIM PIN/PUK
Description
This command is used to inquire times remain to input SIM PIN/PUK.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+SPIC=?
Execution Command
AT+SPIC
Responses
OK
Responses
+SPIC: <pin1> , <puk1> , <pin2> , <puk2>
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<pin1>
Times remain to input PIN1 code.
<puk1>
Times remain to input PUK1 code.
<pin2>
Times remain to input PIN2 code.
<puk2>
Times remain to input PUK2 code.
Examples
AT+SPIC=?
OK
AT+SPIC
+SPIC: 3,10,0,10
OK
4.7
AT+CSPN Get service provider name from SIM
Description
This command is used to get service provider name from SIM card.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSPN=?
Read Command
AT+CSPN?
Responses
OK
ERROR
Responses
+CSPN: <spn> , <display mode>
OK
OK
+CME ERROR: <err>
Defined values
<spn>
String type; service provider name on SIM
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<display mode>
0 – doesn’t display PLMN. Already registered on PLMN.
1 – display PLMN
Examples
AT+CSPN=?
OK
AT+CSPN?
+CSPN: “CMCC”,0
OK
4.8
AT+CRFSIM Reinitialize the SIM card
Description
This command is used to reload and initialize the SIM card.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CRFSIM=?
Responses
OK
Execute Command
AT+CRFSIM
Responses
OK
ERROR
Examples
AT+CRFSIM=?
OK
AT+CRFSIM
OK
4.9
AT+CSQ Query signal quality
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to return received signal strength indication <rssi> and channel bit error rate
<ber> from the ME. Test command returns values supported by the TA as compound values.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CSQ=?
Execution Command
AT+CSQ
Responses
+CSQ: (list of supported <rssi> s),(list of supported <ber> s)
OK
Responses
+CSQ: <rssi> , <ber>
OK
ERROR
Defined values
<rssi>
0 – -113 dBm or less
1 – -111 dBm
2...30 – -109... -53 dBm
31 – -51 dBm or greater
99 – not known or not detectable
<ber>
(in percent)
0 – <0.01%
1 – 0.01% --- 0.1%
2 – 0.1% --- 0.5%
3 – 0.5% --- 1.0%
4 – 1.0% --- 2.0%
5 – 2.0% --- 4.0%
6 – 4.0% --- 8.0%
7 – >=8.0%
99 – not known or not detectable
Examples
AT+CSQ
+CSQ: 22,0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4.10
AT+AUTOCSQ Set CSQ report
Description
This command is used to enable or disable automatic report CSQ information, when automatic report enabled, the module reports CSQ information every five seconds or only after <rssi> or
<ber> is changed, the format of automatic report is “+CSQ: <rssi> , <ber> ”.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+AUTOCSQ=?
Read Command
AT+AUTOCSQ?
Write Command
AT+AUTOCSQ= <auto> [, < mode> ]
Responses
+AUTOCSQ: (list of supported <auto> s),(list of supported <mod e> s)
OK
Responses
+AUTOCSQ: <auto> , <mode>
OK
Responses
OK
ERROR
Defined values
<auto>
0 – disable automatic report
1 – enable automatic report
<mode>
0 – CSQ automatic report every five seconds
1 – CSQ automatic report only after <rssi> or <ber> is changed
NOTE: If the parameter of <mode> is omitted when executing write command, <mode> will be set to default value.
Examples
AT+AUTOCSQ=?
+AUTOCSQ: (0-1),(0-1)
OK
AT+AUTOCSQ?
+AUTOCSQ: 1,1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+AUTOCSQ=1,1
OK
+CSQ: 23,0 (when <rssi> or <ber> changing)
4.11
AT+CATR Configure URC destination interface
Description
This command is used to configure the serial port which will be used to output URCs. We recommend configure a destination port for receiving URC in the system initialization phase, in particular, in the case that transmitting large amounts of data, e.g. use
TCP/UDP/FTP(S)/HTTP(S)/SSL and MT SMS related AT command.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CATR=?
Read Command
AT+CATR?
Responses
+CATR: (list of supported <port> s),( list of supported <save> s)
OK
Responses
+CATR: <port>
OK
Write Command
AT+CATR= <port> [, <save> ]
Responses
OK
ERROR
Defined values
<port>
0 – all ports
1 – use UART port to output URCs
2 – use MODEM port to output URCs
3 – use ATCOM port to output URCs
4 – use MUX port, corresponding to DLCI 1 of UART multiplexor protocol.
5 – use MUX port, corresponding to DLCI 2 of UART multiplexor protocol.
6 – use MUX port, corresponding to DLCI 3 of UART multiplexor protocol.
7 – use MUX port, corresponding to DLCI 4 of UART multiplexor protocol.
NOTE:
When use MUX port to output URCs, the service of corresponding MUX port should configure as DATA service by AT+CMUXSRVPORT command.
<save>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0 – set temporarily
1 – set permanently
Examples
AT+CATR=1,0
OK
AT+CATR?
+CATR: 1
OK
4.12
AT+CFBDURC Disable URC reporting
Description
This command is used to enable or disable URC reporting. The report of the following modules will not be regarded as URC:
TCPIP/MMS/FTP/SMTP/POP3/HTTP/FTPS/SMTPS/HTTPS/COMMON CHANNEL.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFBDURC=?
Read Command
AT+CFBDURC?
Write Command
AT+ CFBDURC= <mode>
Responses
+CFBDURC: (0,1)
OK
Responses
+CFBDURC: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
The mode of disabling URC:
0 – Not disable.
1 – Disable.
Examples
AT+CFBDURC=1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4.13
AT+CPOF Power down the module
Description
This command is used to power off the module. Once the AT+CPOF command is executed, The module will store user data and deactivate from network, and then shutdown.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CPOF=?
Execution Command
AT+CPOF
Responses
OK
Responses
OK
Examples
AT+CPOF
OK
4.14
AT+CRESET Reset the module
Description
This command is used to reset the module.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CRESET=?
Execute Command
AT+CRESET
Examples
AT+CRESET=?
Responses
OK
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CRESET
OK
4.15
AT+CACM Accumulated call meter
Description
This command is used to reset the Advice of Charge related accumulated call meter value in SIM file EF
ACM
.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CACM=?
Read Command
AT+CACM?
Write Command
AT+CACM= <passwd>
Execution Command
AT+CACM
Responses
OK
Responses
+CACM: <acm>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
+CME ERROR: <err>
Defined values
<passwd>
String type, SIM PIN2.
<acm>
String type, accumulated call meter value similarly coded as <ccm> under +CAOC.
Examples
AT+CACM?
+CACM: "000000"
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4.16
AT+CAMM Accumulated call meter maximum
Description
This command is used to set the Advice of Charge related accumulated call meter maximum value in SIM file EF
ACMmax.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CAMM=?
Read Command
AT+CAMM?
Write Command
AT+CAMM=
<acmmax> [, <passwd> ]
Execution Command
AT+CAMM
Responses
OK
Responses
+CAMM: <acmmax>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
+CME ERROR: <err>
Defined values
<acmmax>
String type, accumulated call meter maximum value similarly coded as <ccm> under AT+CAOC , value zero disables ACMmax feature.
<passwd>
String type, SIM PIN2.
Examples
AT+CAMM?
+CAMM: "000000"
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4.17
AT+CPUC Price per unit and currency table
Description
This command is used to set the parameters of Advice of Charge related price per unit and currency table in SIM file EF
PUCT
..
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CPUC=?
Read Command
AT+CPUC?
Write Command
AT+CPUC= <currency> ,
<ppu> [, <passwd> ]
Responses
OK
Responses
+CPUC: [ <currency> , <ppu> ]
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<currency>
String type, three-character currency code (e.g. "GBP", "DEM"), character set as specified by command Select TE Character Set AT+CSCS .
<ppu>
String type, price per unit, dot is used as a decimal separator. (e.g. "2.66").
<passwd>
String type, SIM PIN2.
Examples
AT+CPUC?
+CPUC: “GBP” , “2.66”
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4.18
AT+CCLK Real time clock management
Description
This command is used to manage Real Time Clock of the module.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CCLK=?
Read Command
AT+CCLK?
Write Command
AT+CCLK= <time>
Responses
OK
Responses
+CCLK: <time>
OK
Responses
OK
ERROR
Defined values
<time>
String type value; format is “yy/MM/dd,hh:mm:ss ± zz”, where characters indicate year (two last digits), month, day, hour, minutes, seconds and time zone (indicates the difference, expressed in quarters of an hour, between the local time and GMT; three last digits are mandatory, range
-47…+48). E.g. 6 th
of May 2008, 14:28:10 GMT+8 equals to “08/05/06,14:28:10+32”.
NOTE: 1. Time zone is nonvolatile, and the factory value is invalid time zone.
2. Command +CCLK ? will return time zone when time zone is valid, and if time zone is
00, command +CCLK ? will return “+00”, but not “-00”.
Examples
AT+CCLK=“08/11/28,12:30:33+32”
OK
AT+CCLK?
+CCLK: “08/11/28,12:30:35+32”
OK
AT+CCLK=“08/11/26,10:15:00”
OK
AT+CCLK?
+CCLK: “08/11/26,10:15:02+32”
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4.19
AT+CMEE Report mobile equipment error
Description
This command is used to disable or enable the use of result code “+CME ERROR: <err> ” or
“+CMS ERROR: <err> ” as an indication of an error relating to the functionality of ME; when enabled, the format of <err> can be set to numeric or verbose string.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CMEE=?
Read Command
AT+CMEE?
Write Command
AT+CMEE= <n>
Execution Command
AT+CMEE
Responses
+CMEE: (list of supported <n> s)
OK
Responses
+CMEE: <n>
OK
Responses
OK
ERROR
Responses
Set default value:
OK
Defined values
<n>
0 – Disable result code,i.e. only “ERROR” will be displayed.
1 – Enable error result code with numeric values.
2 – Enable error result code with string values.
Examples
AT+CMEE?
+CMEE: 2
OK
AT+CPIN="1234","1234"
+CME ERROR: incorrect password
AT+CMEE=0
OK
AT+CPIN="1234","1234"
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
ERROR
AT+CMEE=1
OK
AT+CPIN="1234","1234"
+CME ERROR: 16
4.20
AT+CPAS Phone activity status
Description
This command is used to return the activity status <pas> of the ME. It can be used to interrogate the
ME before requesting action from the phone.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CPAS=?
Execution Command
AT+CPAS
Responses
+CPAS: (list of supported <pas> s)
OK
Responses
+CPAS: <pas>
OK
Defined values
<pas>
0 – ready (ME allows commands from TA/TE)
3 – ringing (ME is ready for commands from TA/TE, but the ringer is active)
4 – call in progress (ME is ready for commands from TA/TE, but a call is in progress)
Examples
RING (with incoming call)
AT+CPAS
+CPAS: 3
OK
AT+CPAS=?
+CPAS: (0,3,4)
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4.21
AT+SIMEI Set IMEI for the module
Description
This command is used to set the module’s IMEI value.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+SIMEI=?
Read Command
AT+SIMEI?
Write Command
AT+SIMEI= <imei>
Responses
OK
Responses
+SIMEI: <imei>
OK
Responses
OK
ERROR
Defined values
<imei>
The 15-digit IMEI value.
Examples
AT+SIMEI=357396012183170
OK
AT+SIMEI?
+SIMEI: 357396012183170
OK
AT+SIMEI=?
OK
4.22
AT+DSWITCH Change diagnostics port mode
Description
This command is used to change diagnostics port mode.The default mode of diagnostics port is debug mode. User can switch it from debug mode to data mode or from data mode to debug mode.Under data mode, you can send and receive PCM data.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
NO Vendor
Syntax
Test Command
AT+DSWITCH=?
Read Command
AT+DSWITCH?
Write Command
AT+DSWITCH = <mode>
Responses
+DSWITCH: (list of supported <mode> s)
OK
Responses
+DSWITCH: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
Pamameter shows the settings of diagnostics port
0 Switch from data mode to debug mode
1 Switch from debug mode to data mode
Examples
AT+DSWITCH=?
+DSWITCH: (0-1)
OK
AT+DSWITCH?
+DSWITCH: 0
OK
AT+DSWITCH=1
OK
4.23
AT+CDELTA Write delta package to FOTA partition
Description
This command is used to write the delta package to FOTA partition, during the next startup time the module will start to update the firmware with this delta package.
SIM PIN References
NO Vendor
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Test Command
AT+CDELTA=?
Write Command
AT+CDELTA= <delta_packa ge>
Responses
OK
Responses
If successful,return:
+CDELTA: 1
OK
If fail,return:
+CDELTA: 0, <err_code>
OK
Defined values
<delta_package>
File name of delta package (string type).
<delta_package> must be double quoted.
Please refer to “NOTE” section for more detail.
<err_code>
The error code of writing delta package.
0 The delta package does not existed
1 Error occurs when reading delta package
2 Error occurs when writing delta package to FOTA partition
3 Set the flag for updateing unsuccessfully
Examples
AT+CDELTA=?
OK
AT+CDELTA=”delta_1_2.mld”
+CDELTA: 1
OK
NOTE:
1. Delta package can be saved in the module EFS, this command will lookup the package under current directory. BTW you can use AT+FSCD to change the current directory.
2. After the command finished excuting, user needs to reset the module to start the updating process; during the process the status led will blink for attention. Please refer to
“SIM52xx_Delta_Package_Update_Application_note_V0.01.doc” for more detail.
4.24
AT+CSQDELTA Set RSSI delta change threshold
Description
This command is used to set RSSI delta threshold for signal strength reporting.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSQDELTA=?
Read Command
AT+CSQDELTA?
Write Command
AT+CSQDELTA= <delta>
Execution Command
AT+CSQDELTA
Responses
+CSQDELTA: (list of supported <delta> s)
OK
Responses
+CSQDELTA: <delta>
OK
ERROR
Responses
OK
ERROR
Responses
Set default value
(
<delta> =5
)
:
OK
Defined values
<delta>
Range: from 0 to 5.
Examples
AT+CSQDELTA?
+CSQDELTA: 5
OK
4.25
AT+CSVM Voice Mail Subscriber number
Description
Execution command returns the voice mail number related to the subscriber.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CSVM=?
Responses
+CSVM: (0-1), “(0-9,+)”, (128-255)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+CSVM?
Write Command
AT+CSVM= <valid> ,
“ <number> ”, <type>
OK
Responses
+CSVM: <valid> , “ <number> ”, <type>
OK
ERROR
Responses
OK
ERROR
Defined values
<valid>
Whether voice mail number is valid:
0 – Voice mail number is invalid.
1 – Voice mail number is valid.
<number>
String type phone number of format specified by <type> .
<type>
Type of address octet in integer format. see also AT+CPBR <type>
Examples
AT+CSVM?
+CSVM: 1 ,"13697252277",129
OK
4.26
Indication of EONS
This module supports EONS function; the following table shows the URC related EONS.
OPL INIT
OPL DONE
PNN INIT
PNN DONE
OPL UPDATING
OPL UPDATING
PNN UPDATING
Description
This indication means EF-OPL has been read successfully. Only after this URC is reported, the AT+COPS? can query the network name that supports EONS function.
Description
This indication means EF-PNN has been read successfully
Description
This indication means the EF-OPL is updating using OTA message.
After updating, the “OPL DONE” should report.
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
PNN UPDATING
PNN UPDATING
This indication means the EF-PNN is updating using OTA message. After updating, the “PNN DONE” should report.
This indication means the EF-PNN is updating using OTA message. After updating, the “PNN DONE” should report.
4.27
Indication of Voice Mail
This module supports voice mail function; the subscriber number is configured by AT+CSVM command, the following table shows the URC related Voice Mail.
Box Empty
+VOICEMAIL: EMPTY
Description
This indication means the voice mail box is empty
New Message Description
+VOICEMAIL: NEW MSG This indication means there is a new voice mail message notification received. This is for CPHS.
Voice Mail Status Updated Description
+VOICEMAIL: WAITING, This indication means that there are <count> number of voice
<count> mail messages that needs to be got.
Defined values
< count>
Count of voice mail message that waits to be got.
Examples
+VOICEMAIL: WAITING, <count>
+VOICEMAIL: WAITING, 5
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
5 AT Commands for Network
5.1
AT+CREG Network registration
Description
This command is used to control the presentation of an unsolicited result code +CREG: <stat> when <n> =1 and there is a change in the ME network registration status, or code +CREG:
<stat> [, <lac> , <ci> ] when <n> =2 and there is a change of the network cell.
Read command returns the status of result code presentation and an integer <stat> which shows whether the network has currently indicated the registration of the ME. Location information elements <lac> and <ci> are returned only when <n> =2 and ME is registered in the network.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CREG=?
Read Command
AT+CREG?
Write Command
AT+CREG = <n>
Execution Command
AT+CREG
Responses
+CREG: (list of supported <n> s)
OK
Responses
+CREG: <n> , <stat> [, <lac> , <ci> ]
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
Set default value ( <n> =0 ) :
OK
Defined values
<n>
0 – disable network registration unsolicited result code
1 – enable network registration unsolicited result code +CREG: <stat>
2 – enable network registration and location information unsolicited result code +CREG:
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<stat> [, <lac> , <ci> ]
<stat>
0 – not registered, ME is not currently searching a new operator to register to
1 – registered, home network
2 – not registered, but ME is currently searching a new operator to register to
3 – registration denied
4 – unknown
5 – registered, roaming
<lac>
Two byte location area code in hexadecimal format(e.g.”00C3” equals 193 in decimal).
<ci>
Cell ID in hexadecimal format.
GSM : Maximum is two byte
WCDMA : Maximum is four byte
Examples
AT+CREG?
+CREG: 0,1
OK
5.2
AT+COPS Operator selection
Description
Write command forces an attempt to select and register the GSM/UMTS network operator. <mode> is used to select whether the selection is done automatically by the ME or is forced by this command to operator <oper> (it shall be given in format <format> ). If the selected operator is not available, no other operator shall be selected (except <mode> =4). The selected operator name format shall apply to further read commands ( AT+COPS ?) also. <mode> =2 forces an attempt to deregister from the network. The selected mode affects to all further network registration (e.g. after
<mode> =2, ME shall be unregistered until <mode> =0 or 1 is selected).
Read command returns the current mode and the currently selected operator. If no operator is selected, <format> and <oper> are omitted.
Test command returns a list of quadruplets, each representing an operator present in the network.
Quadruplet consists of an integer indicating the availability of the operator <stat> , long and short alphanumeric format of the name of the operator, and numeric format representation of the operator.
Any of the formats may be unavailable and should then be an empty field. The list of operators shall be in order: home network, networks referenced in SIM, and other networks.
It is recommended (although optional) that after the operator list TA returns lists of supported
<mode> s and <format> s. These lists shall be delimited from the operator list by two commas.
When executing AT+COPS=? , any input from serial port will stop this command.
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
NO 3GPP TS 27.007
Syntax
Test Command
AT+COPS=?
Read Command
AT+COPS?
Write Command
AT+COPS= <mode> [, <form at >[, <oper> [, < AcT> ]]]
Execution Command
AT+COPS
Responses
+COPS: [list of supported ( <stat> ,long alphanumeric <oper>
,short alphanumeric <oper> ,numeric <oper> [, < AcT> ])s]
[,,(list of supported <mode> s),(list of supported <format> s)]
OK
ERROR
+CME ERROR: <err>
Responses
+COPS: <mode> [, <format> , <oper> [, < AcT> ]]
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
Defined values
<mode>
0
–
automatic
1
–
manual
2
–
force deregister
3
–
set only <format>
4
–
manual/automatic
5
– manual,but do not modify the network selection mode(e.g GSM,WCDMA) after module resets.
<format>
0
–
long format alphanumeric <oper>
1
–
short format alphanumeric <oper>
2
–
numeric <oper>
<oper> type, indicates if the format is alphanumeric or numeric.
<stat>
0
–
unknown
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
1
–
available
2
–
current
3
–
forbidden
<AcT>
Access technology selected
0
–
GSM
1
–
GSM Compact
2
–
UTRAN
Examples
AT+COPS?
+COPS: 0,0,"China Mobile Com",0
OK
AT+COPS=?
+COPS: (2,"China Unicom","Unicom","46001",0),(3,"China Mobile Com","DGTMPT",
"46000",0),,(0,1,2,3,4,5),(0,1,2)
OK
5.3
AT+CLCK Facility lock
Description
This command is used to lock, unlock or interrogate a ME or a network facility <fac> . Password is normally needed to do such actions. When querying the status of a network service ( <mode> =2) the response line for 'not active' case ( <status> =0) should be returned only if service is not active for any <class> .
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CLCK=?
Write Command
AT+CLCK= <fac> , <mode>
[, <passwd> [, <class> ]]
Responses
+CLCK: (list of supported <fac> s)
OK
+CME ERROR: <err>
Responses
OK
When <mode>=2 and command successful:
+CLCK: <status> [, <class1> [<CR><LF>
+CLCK: <status> , <class2>
[...]]
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
+CME ERROR: <err>
Defined values
<fac>
"PF" lock Phone to the very First inserted SIM card or USIM card
"SC" lock SIM card or USIM card
"AO" Barr All Outgoing Calls
"OI" Barr Outgoing International Calls
"OX" Barr Outgoing International Calls except to Home Country
"AI" Barr All Incoming Calls
"IR" Barr Incoming Calls when roaming outside the home country
"AB" All Barring services (only for <mode> =0)
"AG" All outGoing barring services (only for <mode> =0)
"AC" All inComing barring services (only for <mode> =0)
"FD" SIM fixed dialing memory feature
"PU" network subset Personalization
"PP" service Provider Personalization
"PC" Corporate Personalization
<mode>
0 – unlock
1 – lock
2 – query status
<status>
0 – not active
1 – active
<passwd>
Password. string type; shall be the same as password specified for the facility from the ME user interface or with command Change Password +CPWD
<classX>
It is a sum of integers each representing a class of information (default 7):
1 – voice (telephony)
2 – data (refers to all bearer services)
4 – fax (facsimile services)
8 – short message service
16 – data circuit sync
32 – data circuit async
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
64 – dedicated packet access
128 – dedicated PAD access
255 – The value 255 covers all classes
Examples
AT+CLCK="SC",2
+CLCK: 0
OK
5.4
AT+CPWD Change password
Description
Write command sets a new password for the facility lock function defined by command Facility
Lock AT+CLCK .
Test command returns a list of pairs which present the available facilities and the maximum length of their password.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CPWD=?
Responses
+CPWD: (list of supported ( <fac> , <pwdlength> )s)
OK
+CME ERROR: <err>
Write Command Responses
AT+CPWD= OK
<fac> , <oldpwd> , <newpwd>
+CME ERROR: <err>
Defined values
<fac>
Refer Facility Lock +CLCK for other values:
"SC" SIM or USIM PIN1
"P2" SIM or USIM PIN2
"AB" All Barring services
"AC" All inComing barring services (only for <mode> =0)
"AG" All outGoing barring services (only for <mode> =0)
"AI" Barr All Incoming Calls
"AO" Barr All Outgoing Calls
"IR" Barr Incoming Calls when roaming outside the home country
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
"OI" Barr Outgoing International Calls
"OX" Barr Outgoing International Calls except to Home Country
<oldpwd>
String type, it shall be the same as password specified for the facility from the ME user interface or with command Change Password AT+CPWD .
<newpwd>
String type, it is the new password; maximum length of password can be determined with
<pwdlength> .
<pwdlength>
Integer type, max length of password.
Examples
AT+CPWD=?
+CPWD: ("AB",4),("AC",4),("AG",4),("AI",4),("AO",4),("IR",4),("OI",4),("OX",4),(
"SC",8),("P2",8)
OK
5.5
AT+CCUG Closed user group
Description
This command allows control of the Closed User Group supplementary service. Set command enables the served subscriber to select a CUG index, to suppress the Outgoing Access (OA), and to suppress the preferential CUG.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CCUG=?
Read Command
AT+CCUG?
Write Command
AT+CCUG=
<n> [, <index> [, <info> ]]
Responses
OK
Responses
+CCUG: <n> , <index> , <info>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Execution Command
AT+CCUG
Responses
Set default value:
OK
Defined values
<n>
0 – disable CUG temporary mode
1 – enable CUG temporary mode
<index>
0...9 – CUG index
10 – no index (preferred CUG taken from subscriber data)
<info>
0 – no information
1 – suppress OA
2 – suppress preferential CUG
3 – suppress OA and preferential CUG
Examples
AT+CCUG?
+CCUG: 0,0,0
OK
5.6
AT+CUSD Unstructured supplementary service data
Description
This command allows control of the Unstructured Supplementary Service Data (USSD). Both network and mobile initiated operations are supported. Parameter <n> is used to disable/enable the presentation of an unsolicited result code (USSD response from the network, or network initiated operation) +CUSD: <m> [, <str> , <dcs> ] to the TE. In addition, value <n> =2 is used to cancel an ongoing USSD session.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CUSD=?
Read Command
Responses
+CUSD: (list of supported <n> s)
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CUSD?
Write Command
AT+CUSD=
<n> [, <str> [, <dcs> ]]
Execution Command
AT+CUSD
+CUSD: <n>
OK
Responses
OK
ERROR
+CME ERROR: <err>
Responses
Set default value ( <n> =0):
OK
Defined values
<n>
0 – disable the result code presentation in the TA
1 – enable the result code presentation in the TA
2 – cancel session (not applicable to read command response)
<str>
String type USSD-string.
<dcs>
Cell Broadcast Data Coding Scheme in integer format (default 0).
<m>
0 – no further user action required (network initiated USSD-Notify, or no further information needed after mobile initiated operation)
1 – further user action required (network initiated USSD-Request, or further information needed after mobile initiated operation)
2 – USSD terminated by network
4 – operation not supported
5 – network time out
Examples
AT+CUSD?
+CUSD: 1
OK
AT+CUSD=0
OK
5.7
AT+CAOC Advice of charge
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command refers to Advice of Charge supplementary service that enables subscriber to get information about the cost of calls. With <mode> =0, the execute command returns the current call meter value from the ME.
This command also includes the possibility to enable an unsolicited event reporting of the CCM information. The unsolicited result code +CCCM: <ccm> is sent when the CCM value changes, but not more that every 10 seconds. Deactivation of the unsolicited event reporting is made with the same command.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CAOC=?
Read Command
AT+CAOC?
Write Command
AT+CAOC= <mode>
Execution Command
AT+ CAOC
Responses
+CAOC: (list of supported <mode> s)
OK
Responses
+CAOC: <mode>
OK
ERROR
+CME ERROR: <err>
Responses
+CAOC: <ccm>
OK
OK
ERROR
+CME ERROR: <err>
Responses
Set default value ( <mode> =1):
OK
Defined values
<mode>
0 – query CCM value
1 – deactivate the unsolicited reporting of CCM value
2 – activate the unsolicited reporting of CCM value
<ccm>
String type, three bytes of the current call meter value in hexadecimal format (e.g. "00001E" indicates decimal value 30), value is in home units and bytes are similarly coded as ACMmax value in the SIM.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CAOC=0
+CAOC: "000000"
OK
5.8
AT+CSSN Supplementary service notifications
Description
This command refers to supplementary service related network initiated notifications. The set command enables/disables the presentation of notification result codes from TA to TE.
When <n> =1 and a supplementary service notification is received after a mobile originated call setup, intermediate result code +CSSI: <code1> [, <index> ] is sent to TE before any other MO call setup result codes presented in the present document. When several different <code1> s are received from the network, each of them shall have its own +CSSI result code.
When <m> =1 and a supplementary service notification is received during a mobile terminated call setup or during a call, or when a forward check supplementary service notification is received, unsolicited result code +CSSU: <code2> [, <index> [, <number> , <type> [, <subaddr> , <satype> ]]] is sent to TE. In case of MT call setup, result code is sent after every +CLIP result code (refer command "Calling line identification presentation +CLIP") and when several different <code2> s are received from the network, each of them shall have its own +CSSU result code.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CSSN=?
Read Command
AT+CSSN?
Write Command
AT+CSSN= <n> [, <m> ]
Responses
+CSSN: (list of supported <n> s),(list of supported <m> s)
OK
Responses
+CSSN: <n> , <m>
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<n>
Parameter sets/shows the +CSSI result code presentation status in the TA:
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0 – disable
1 – enable
<m>
Parameter sets/shows the +CSSU result code presentation status in the TA:
0 – disable
1 – enable
<code1>
0 – unconditional call forwarding is active
1 – some of the conditional call forwarding are active
2 – call has been forwarded
3 – call is waiting
5 – outgoing calls are barred
<index>
Refer "Closed user group +CCUG".
<code2>
0 – this is a forwarded call (MT call setup)
2 – call has been put on hold (during a voice call)
3 – call has been retrieved (during a voice call)
5 – call on hold has been released (this is not a SS notification) (during a voice call)
<number>
String type phone number of format specified by <type> .
<type>
Type of address octet in integer format; default 145 when dialing string includes international access code character "+", otherwise 129.
<subaddr>
String type sub address of format specified by <satype> .
<satype>
Type of sub address octet in integer format, default 128.
Examples
AT+CSSN=1,1
OK
AT+CSSN?
+CSSN: 1,1
OK
5.9
AT+CPOL Preferred operator list
Description
This command is used to edit the SIM preferred list of networks.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CPOL=?
Read Command
AT+CPOL?
Write Command
AT+CPOL= <index>
[, <format >[, <oper> ][, <GSM
_AcT1> , <GSM_Compact_A cT1> , <UTRAN_AcT1> ]]
Responses
+CPOL: (list of supported <index> s), (list of supported <format> s)
OK
Responses
[+CPOL: <index1> , <format> , <oper1> [ <GSM_AcT1> , <GSM_Com pact_AcT1> , <UTRAN_AcT1> ][<CR><LF>
+CPOL:
<index2> , <format> , <oper2> [, <GSM_AcT1> , <GSM_Compact_Ac
T1> , <UTRAN_AcT1> ]
[...]]]
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<index>
Integer type, the order number of operator in the SIM preferred operator list.
If only input <index> , command will delete the value indicate by <index> .
<format>
0 – long format alphanumeric <oper>
1 – short format alphanumeric <oper>
2 – numeric <oper>
<operX>
String type.
<GSM_AcT n >
GSM access technology:
0 – access technology not selected
1 – access technology selected
<GSM_Compact_AcT n >
GSM compact access technology:
0 – access technology not selected
1 – access technology selected
<UTRA_AcT n >
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
UTRA access technology:
0 – access technology not selected
1 – access technology selected
NOTE: If using USIM card, the last three parameters must set.
Examples
AT+CPOL?
+CPOL: 1,2,"46001",0,0,1
OK
AT+CPOL=?
+CPOL: (1-8),(0-2)
OK
5.10
AT+COPN Read operator names
Description
This command is used to return the list of operator names from the ME. Each operator code
<numericX> that has an alphanumeric equivalent <alphaX> in the ME memory shall be returned.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+COPN=?
Write Command
AT+COPN
Responses
OK
Responses
+COPN: <numeric1> , <alpha1> [<CR><LF>
+COPN: <numeric2> , <alpha2>
[...]]
OK
ERROR
+CME ERROR: <err>
Defined values
<numericX>
String type, operator in numeric format (see AT+COPS ).
<alphaX>
String type, operator in long alphanumeric format (see AT+COPS ).
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+COPN
+COPN: "46000","China Mobile Com"
+COPN: "46001"," China Unicom"
……
OK
5.11
AT+CNMP Preferred mode selection
Description
This command is used to select or set the state of the mode preference.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CNMP=?
Read Command
AT+CNMP?
Write Command
AT+CNMP= <mode>
Responses
+CNMP: (list of supported <mode> s)
OK
Responses
+CNMP: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
2 – Automatic
13 – GSM Only
14 – WCDMA Only
Examples
AT+CNMP=13
OK
AT+CNMP?
+CNMP: 2
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
5.12
AT+CNBP Preferred band selection
Description
This command is used to select or set the state of the band preference.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CNBP?
Write Command
AT+CNBP= <mode>
Responses
+CNBP: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
64bit number, the value is “1” << “ <pos> ”, then or by bit.
<pos>
Value:
0xFFFFFFFF7FFFFFFF Any (any value)
21 GSM_PCS_1900
22 WCDMA_IMT_2000
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CNBP=0x000700000FFF0380
OK
AT+CNBP?
+CNBP: 0xFFFFFFFF3FFFFFFF
OK
5.13
AT+CNAOP Acquisitions order preference
Description
This command is used to reset the state of acquisitions order preference.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CNAOP=?
Read Command
AT+CNAOP?
Write Command
AT+CNAOP= <mode>
Responses
+CNAOP: (list of supported <mode> s)
OK
Responses
+CNAOP: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
0 – Automatic
1 – GSM,WCDMA
2 – WCDMA,GSM
Examples
AT+CNAOP=1
OK
AT+CNAOP?
+CNAOP: 2
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
5.14
AT+CNSDP Preferred service domain selection
Description
This command is used to reset the state of the service domain preference.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CNSDP=?
Read Command
AT+CNSDP?
Write Command
AT+CNSDP= <mode>
Responses
+CNSDP: (list of supported <mode> s)
OK
Responses
+CNSDP: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
0 – CS Only
1 – PS Only
2 – CS + PS
Examples
AT+CNSDP=2
OK
AT+CNSDP?
+CNSDP: 0
OK
5.15
AT+CPSI Inquiring UE system information
Description
This command is used to return the UE system information.
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
NO Vendor
Syntax
Test Command
AT+CPSI=?
Read Command
AT+CPSI?
Write Command
AT+CPSI= <time>
Responses
+CPSI: (scope of <time> )
OK
Responses
If camping on a 2G cell:
+CPSI: <System Mode> , <Operation Mode> , <MCC>- <MNC>
<LAC> , <Cell ID> , <Absolute RF Ch Num> , < RxLev > ,
<Track LO Adjust> , <C1-C2>
OK
If camping on a 3G cell:
+CPSI: <System Mode>, <Operation Mode>, <MCC>-
<MNC>,<LAC>,<Cell ID>,<Frequency Band>, <PSC>, <Freq>,
<SSC>,<EC/IO>,< RSCP >,<Qual>,<RxLev>,<TXPWR>
OK
ERROR
Responses
OK
ERROR
Defined values
<time>
The range is 0-255, unit is second, module will reports “+CPSI” URC every <time> seconds automatically when the value of <time> above 0, value equal 0 indicates stop reporting, the format of automatic report is same with response of “AT+CPSI?” command.
<System Mode>
System mode, values: “NO SERVICE”, “GSM” or “WCDMA”.
<Operation Mode>
UE operation mode, values: “Online”,“Offline”,“Factory Test Mode”,“Reset”, “Low Power Mode”.
<MCC>
Mobile Country Code (first part of the PLMN code)
<MNC>
Mobile Network Code (second part of the PLMN code)
<LAC>
Location Area Code (hexadecimal digits)
<Cell ID>
Service-cell ID.
<Absolute RF Ch Num>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AFRCN for service-cell.
<Track LO Adjust>
Track LO Adjust
<C1>
Coefficient for base station selection
<C2>
Coefficient for Cell re-selection
<Frequency Band>
Frequency Band of active set
<PSC>
Primary synchronization code of active set.
<Freq>
Downlink frequency of active set.
<SSC>
Secondary synchronization code of active set
<EC/IO>
Ec/Io value
<RSCP>
Received Signal Code Power
<Qual>
Quality value for base station selection
<RxLev>
RX level value for base station selection
<TXPWR>
UE TX power in dBm. If no TX, the value is 500.
Examples
AT+CPSI?
+CPSI: GSM,Online,460-00 0x182d,12401,27 EGSM 900,-64,2110,42-42
OK
AT+CPSI=?
+CPSI: WCDMA,Online,001-01,0xED2E ,WCDMA IMT 2000,0,9,10688,0,6,62,43,45,500
OK
AT+CPSI=?
+CPSI: (0-255)
OK
5.16
AT+CNSMOD Show network system mode
Description
This command is used to return the current network system mode.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CNSMOD=?
Read Command
AT+CNSMOD?
Write Command
AT+CNSMOD= <n>
Responses
+CNSMOD: (list of supported <n> s)
OK
Responses
+CNSMOD: <n> , <stat>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<n>
0 – disable auto report the network system mode information
1 – enable auto report the network system mode information, command:
+CNSMOD:<stat>
<state>
0 – no service
1 – GSM
2 – GPRS
3 – EGPRS (EDGE)
4 – WCDMA
5 – HSDPA only
6 – HSUPA only
7 – HSPA (HSDPA and HSUPA)
Examples
AT+CNSMOD?
+CNSMOD: 0,2
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
5.17
AT+CTZU Automatic time and time zone update
Description
This command is used to enable or disable automatic time and time zone update via NITZ.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CTZU=?
Read Command
AT+CTZU?
Write Command
AT+CTZU= <onoff>
Responses
+CTZU: (list of supported <onoff> s)
OK
Responses
+CTZU: <onoff>
OK
Responses
OK
ERROR
Defined values
<onoff>
Integer type value indicating:
0 – Disable automatic time zone update via NITZ (default).
1 – Enable automatic time zone update via NITZ.
NOTE: 1. The value of <onoff> is nonvolatile, and factory value is 0.
2. For automatic time and time zone update is enabled ( +CTZU =1):
If time zone is only received from network and it doesn’t equal to local time zone
( AT+CCLK ), time zone is updated automatically, and real time clock is updated based on local time and the difference between time zone from network and local time zone
(Local time zone must be valid).
If Universal Time and time zone are received from network, both time zone and real time clock is updated automatically, and real time clock is based on Universal Time and time zone from network.
Examples
AT+CTZU?
+CTZU: 0
OK
AT+CTZU=1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
5.18
AT+CTZR Time and time zone reporting
Description
This command is used to enable or disable the time zone change event reporting. If the reporting is enabled the MT returns the unsolicited result code +CTZV: <tz> [, <time> ][, <dst> ]whenever the time zone is changed.
NOTE: The time zone reporting is not affected by the Automatic Time and Time Zone command
AT+CTZU .
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CTZR=?
Read Command
AT+CTZR?
Write Command
AT+CTZR= <onoff>
Execution Command
AT+CTZR
Responses
+CTZR: (list of supported <onoff> s)
OK
Responses
+CTZR: <onoff>
OK
Responses
OK
ERROR
Responses
Set default value:
OK
Defined values
<onoff>
Integer type value indicating:
0 – Disable time zone change event reporting (default).
1 – Enable time zone change event reporting.
+CTZV: <tz> [, <time> ][, <dst> ]
Unsolicited result code when time zone received from network doesn’t equal to local time zone, and if the informations from network don’t include date and time, then only time zone will be reported, and if network daylight saving time is present, it is also reported. For example:
+CTZV: 32 (Only report time zone)
+CTZV: 32,1 (Report time zone and network daylight saving time)
+CTZV: 32,08/12/09,17:00:00 (Report time and time zone)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CTZV: 32,08/12/09,17:00:00,1 (Report time, time zone and daylight saving time)
For more detailed informations about time and time zone, please refer 3GPP TS 24.008.
<tz> Local time zone received from network.
<time> Universal time received from network, and the format is “yy/MM/dd,hh:mm:ss”, where characters indicate year (two last digits), month, day, hour, minutes and seconds.
<dst> Network daylight saving time, and if it is received from network, it indicates the value that has been used to adjust the local time zone. The values as following:
0 – No adjustment for Daylight Saving Time.
1 – +1 hour adjustment for Daylight Saving Time.
2 – +2 hours adjustment for Daylight Saving Time.
NOTE: Herein, <time> is Universal Time or NITZ time, but not local time.
Examples
AT+CTZR?
+CTZR: 0
OK
AT+CTZR=1
OK
5.19
AT+CCINFO Show cell system information
Description
This command is used to inquire serving cell and neighbors cell system information.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CCINFO=?
Execution Command
AT+CCINFO
Responses
OK
Responses
For GSM:
When ME in idle mode:
+CCINFO:[ <SCELL> ],ARFCN: <arfcn> ,MCC: <mcc> ,MNC: <mnc
> ,LAC: <lac> ,ID: <id> ,BSIC: <bsic> ,RXLev: <rxlev> ,C1: <c1> ,C2: < c2> ,TA: <TA> ,TXPWR: <TXPWR> <CR><LF>
<CR><LF>+CCINFO:[ <NCELLn> ],ARFCN:< arfcn> ,MCC: <mcc
> ,MNC: <mnc> ,LAC: <lac> ,ID: <id> ,BSIC: <bsic> ,RXLev: <rxlev> ,
C1: <c1> ,C2: <c2> <CR><LF>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<SCELL> indicate serving cell
<NCELLn> available neighbour cell index
<arfcn> assigned radio channel
<uarfcn>
UMTS assigned radio channel
<mcc> mobile country code
<mnc> mobile network code
<lac> localization area code
<id> cell identifier
<bsic> base station identification code
<psc> primary scrambling code
<rscp>
Received Signal Code Power
[…]
When ME in dedicated mode:
<CR><LF>+CCINFO:[ <SCELL> ],ARFCN: <arfcn> ,MCC: <mcc> ,
MNC: <mnc> ,LAC: <lac> ,ID: <id> ,BSIC: <bsic> ,RXLev: <rxlev> db m,C1: <c1> ,C2: <c2>, TA: <TA> ,TXPWR: <TXPWR> <CR><LF>
<CR><LF>+CCINFO:[ <NCelln> ],ARFCN: <arfcn> ,BSIC: <bsic> ,
RXLev: <rxlev> <CR><LF>
[…]
For WCDMA:
+CCINFO:[ <SCELL> ],UARFCN: <uarfcn> ,MCC: <mcc> ,MNC: < mnc> ,LAC: <lac> ,ID: <id> ,PSC: <psc> , SSC: <ssc> , RSCP: <rscp> ,
ECIO: <ecio> ,RXLev: <rxlev> dbm,TXPWR: <TXPWR> <CR><LF>
<CR><LF>+CCINFO:[ <NCelln> ],UARFCN: <uarfcn> ,PSC: <psc> ,
SSC: <ssc> ,RSCP: <rscp> ,ECIO: <ecio> ,RXLev: <rxlev> dbm
<CR><LF>
[…]
OK
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<ecio> chip energy per total wideband power
<ssc> secondary scrambling code
<rxlev> received signal strength in dBm
<TA>
timing advance
<c1>
Coefficient for base station selection
<c2>
Coefficient for Cell re-selection
<TXPWR>
UE TX power in dBm. If no TX, the value is 0.
Examples
AT+CCINFO (idle mode)
+CCINFO:[SCELL],ARFCN:11,MCC:460,MNC:00,LAC:6360,ID:12402,BSIC:52,RXLev:-68dbm,
C1:35,C2:35,TA:0,TXPWR:0
+CCINFO:[NCell1],ARFCN:29,MCC:460,MNC:00,LAC:6360,ID:12625,BSIC:55,RXLev:-81dbm,
C1:21,C2:21
+CCINFO:[NCell2],ARFCN:28,MCC:460,MNC:00,LAC:6360,ID:8466,BSIC:49,RXLev:-81dbm,C
1:21,C2:21
+CCINFO:[NCell3],ARFCN:25,MCC:460,MNC:00,LAC:6360,ID:8498,BSIC:40,RXLev:-81dbm,C
1:21,C2:21
+CCINFO:[NCell4],ARFCN:2,MCC:460,MNC:00,LAC:6362,ID:24644,BSIC:48,RXLev:-87dbm,C
1:15,C2:15
+CCINFO:[NCell5],ARFCN:14,MCC:460,MNC:00,LAC:6360,ID:12403,BSIC:54,RXLev:-86dbm,
C1:16,C2:16
+CCINFO:[NCell6],ARFCN:13,MCC:460,MNC:00,LAC:6362,ID:24705,BSIC:51,RXLev:-89dbm,
C1:13,C2:13
OK
AT+CCINFO (dedicated mode)
+CCINFO:[SCELL],ARFCN:11,MCC:460,MNC:00,LAC:6360,ID:12402,BSIC:52,RXLev:-61dbm,
C1:42,C2:42,TXPWR:29
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CCINFO:[NCell1],ARFCN:25,BSIC:40,RXLev:-81dbm
+CCINFO:[NCell2],ARFCN:28,BSIC:49,RXLev:-82dbm
+CCINFO:[NCell3],ARFCN:29,BSIC:55,RXLev:-82dbm
+CCINFO:[NCell4],ARFCN:14,BSIC:54,RXLev:-87dbm
+CCINFO:[NCell5],ARFCN:2,BSIC:48,RXLev:-89dbm
+CCINFO:[NCell6],ARFCN:13,BSIC:51,RXLev:-89dbm
OK
5.20
AT+CSCHN Show cell channel information
Description
This command is used to inquire serving cell channel information in GSM.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSCHN=?
Execution Command
AT+CSCHN
Defined values
<arfcn> assigned radio channel
<bsic> base station identification code
<hsn>
HSN
<maio>
Responses
OK
Responses
When during a call:
+CSCHN:ARFCN :<arfcn> ,BISC: <bsic> ,HSN: <hsn> ,MAIO: <mai o> , TN: <tn> ,HF: <hf> ,TSC: <tsc> ,TCH: <tch>
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
MAIO
<tn>
timeslot number
<hf> hopping flag
<tsc>
TSC
<tch> channel type
Examples
AT+CSCHN
+CSCHN: ARFCN:11, BISC: 52, HSN: 41, MAIO: 6, TN: 1, HF: 1, TSC: 4, TCH: 3
OK
5.21
AT+CSRP Show serving cell radio parameter
Description
This command is used to inquire serving cell radio parameter in GSM.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSRP=?
Execution Command
AT+CSRP
Defined values
<arfcn> assigned radio channel
<rxlevfull> received full signal strength in dBm
<rxlevsub>
Responses
OK
Responses
When during a call:
+CSRP:ARFCN: <arfcn> ,RXLevFull: <rxlevfull> ,RXLevSub:
<rxlevsub> ,RXQualFull: <rxqualfull> ,RXQualSub: <rxqualsub> ,
PWRC: <pwrc> ,DTX: <dtx>, RLT: <rlt>
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
received sub signal strength in dBm
<rxqualfull> full quality of reception
<rxqualsub> sub quality of reception
<pwrc>
PWRC
<dtx>
DTX
<rlt> radio link timeout
Examples
AT+CSRP
+CSRP:ARFCN:11,RXLevFull:-88dbm,RXLevSub:-89dbm,RXQualFull:7,RXQualSub:7,PWRC:1,
DTX:0,RLT:32
OK
5.22
AT+CRUS Show cell set system information
Description
This command is used to return the mobile phone system information in WCDMA.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CRUS=?
Execution Command
AT+CRUS
Responses
OK
Responses
+CRUS: Active SET, <ActiveSET Cells Num> [, <ActiveSET
Cell1 PSC> , <ActiveSET Cell1 Freq> , <ActiveSET Cell1 SSC> ,
<ActiveSET Cell1 Sttd> , <ActiveSET Cell1 TotEcio> ,
<ActiveSET Cell1 Ecio> , <ActiveSET Cell1 Rscp> ,
<UTMS_SETS Cell TPC>, <UTMS_SETS Cell SecCpichOvsf>,
<ActiveSET Cell1 WinSize> […]]
+CRUS: Sync Neighbor SET, <SyncSET Cells Num> [, <SyncSET
Cell1 PSC> , <SyncSET Cell1 Freq> , < SyncSET Cell1 SSC> , <
SyncSET Cell1 Sttd> , < SyncSET Cell1 TotEcio> , < SyncSET
Cell1 Ecio> , < SyncSET Cell1 Rscp> , < SyncSET Cell1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
WinSize> […]]
+CRUS: Async Neighbor SET, <AsyncSET Cells Num> [, <
AsyncSET Cell1 PSC> , < AsyncSET Cell1 Freq> , < AsyncSET
Cell1 SSC> , < AsyncSET Cell1 Sttd> , < AsyncSET Cell1
TotEcio> , < AsyncSET Cell1 Ecio> , < AsyncSET Cell1 Rscp> , <
AsyncSET Cell1 WinSize> […]]
OK
Defined values
<UTMS_SETS Cells Num> cells number
<UTMS_SETS Cell 1-n PSC> primary synchronization code of the cell
<UTMS_SETS Cell 1-n Freq> downlink frequency of the cell
<UTMS_SETS Cell 1-n SSC> secondary synchronization code
<UTMS_SETS Cell 1-n Sttd> if the CPICH of this cell uses STTD
<UTMS_SETS Cell 1-n TotEcio> the total Ec/Io in the best paths found in a sweep
<UTMS_SETS Cell 1-n 1 Ecio>
Ec/Io
<UTMS_SETS Cell 1-n Rscp>
CPICH RSCP
<UTMS_SETS Cell 1-n TPC>
Forward power control combination
<UTMS_SETS Cell 1-n SecCpichOvsf>
OVSF code of the secondary CPICH
<UTMS_SETS Cell 1-n WinSize> search window size for this cell
UTMS_SETS contains:
ActiveSET active set
SyncSET neighbor (monitored) set for neighbors whose timing is known
AsyncSET neighbor (monitored) set for neighbors whose timing is unknown
Examples
AT+CRUS
+CRUS: Active SET,1,2,10663,0,0,16,16,101,0,0,1536
+CRUS: Sync Neighbor SET,2,42,10663,0,0,34,33,109,1536,35,10663,0,0,26,26,106,1536
+CRUS: Async Neighbor SET,10,11,10663,0,0,0,49,121,0,6,10663,0,0,0,49,121,0,28, 10663, 0, 0,0,
49,121,0,247,10663,0,0,0,49,121,0,193,10663,0,0,0,49,121,0,493,10663,0,0,0,49,121,0,485,10663,
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0,0,0,49,121,0,258,10663,0,0,0,49,121,0,109,10663,0,0,0,49,121,0,226,10663,0,0,38,49,121,1536
OK
5.23
AT+CPLMNWLIST Manages PLMNs allowed by customer
Description
This command is used to manage the PLMN list allowed by customer. After setting the plmnwlist, The setting will be take effect on the next power up time.
SIM PIN References
NO Vendor
Syntax
Read Command
AT+CPLMNWLIST?
Write Command
AT+CPLMNWLIST= <plmn wlist> [, <type> ]
Responses
+CPLMNWLIST: <plmnwlist>,<type>
OK
Responses
OK
ERROR
Defined values
<plmnwlist>
The list of PLMN separated by semicolon. The maximum count of the items in the list is 20.
Empty list represents no filter. If the CPASSMGR has set password for this command, the password must be verified before operating this command.
<type>
The type of PLMN filter:
1 – filter by HPLMN.
2 – filter by PLMN of the wireless network.
3 – filter by both HPLMN and PLMN of the wireless network.
Examples
AT+CPLMNWLIST= “46000;46001”
OK
AT+CPLMNWLIST=””
OK
AT+CPLMNWLIST?
+CPLMNWLIST: “46000;46001”, 1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
5.24
AT+CPASSMGR Manage password
Description
This command is used to manage password for some AT commands.
SIM PIN References
NO Vendor
Syntax
Write Command
AT+CPASSMGR= <module
> ," <password> "[,
<new_password> ]
Responses
OK
ERROR
Defined values
<module>
The module for the password operation:
"cplmnwlist" – AT+CPLMNWLIST command
"portmode" – Used for locking DIAG port. No AT command affected.
"imei" – AT+SIMEI command
<password>
The password for the module. The maximum length is 8.
<new_password>
The new password for the module. The maximum length is 8.
Examples
AT+CPASSMGR=”cplmnwlist”, “”, “12345678”
OK
AT+CPASSMGR=”cplmnwlist”, “12345678”, “111111”
OK
AT+CPASSMGR=”cplmnwlist”,”111111”
OK
AT+CPASSMGR=”cplmnwlist”,”111111”,””
OK
5.25
AT+CNSVSQ Network band scan quickly
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to perform a quick survey through channels belonging to the band selected, starting from channel <s> to channel <e> . If parameters are omitted, a full band scan is performed.
After issuing the command, the information for every received BCCH (BCCH-Carrier and non
BCCH-Carrier) is reported in the format of string.
SIM PIN References
NO Vendor
Syntax
Write Command
AT+CNSVSQ= <s> , <e>
Execution Command
AT+CNSVSQ
Responses
Network survey started...
For BCCH-Carrier:
[arfcn: <arfcn_value> ,bsic: <bsic_value> ,dBm: <dBm_value> ]
[ … ]
For non BCCH-Carrier:
[arfch: <arfcn_value> ,dBm: <dBm_value> ]
[ … ]
Network survey end
OK
ERROR
Responses
Network survey started...
For BCCH-Carrier:
[arfcn: <arfcn_value> ,bsic: <bsic_value> ,dBm: <dBm_value> ]
[ … ]
For non BCCH-Carrier:
[arfch: <arfcn_value> ,dBm: <dBm_value> ]
[ … ]
Network survey end
OK
Defined values
<s> starting channel.
<e> ending channel.
<arfcn_value> carrier assigned radio channel (BCCH – Broadcast Control Channel).
<bsic_value> base station identification code.
<dBm_value> the value of dBm.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CNSVSQ
Network survey started…
For BCCH-Carrier: arfcn: 16,bsic: 45,dBm: -75
……
For non BCCH-Carrier: arfcn: 89,dBm: -82 arfcn: 1011,dBm: -86
……
Network survey end
OK
5.26
AT+CNSVS Network full band scan in string format
Description
This command is used to perform a quick survey through channels belonging to the band selected , starting from channel <s> to channel <e> . If parameters are omitted, a full band scan is performed.
After issuing the command, the information for every received BCCH(BCCH-Carrier and non
BCCH-Carrier) is reported in the format of string.
SIM PIN References
NO Vendor
Syntax
Read Command
AT+CNSVS?
Write Command
AT+CNSVS= <s> , <e>
Responses
+CNSVS: <count>
OK
Responses
Network survey started…
For BCCH-Carrier:
[arfcn: <arfcn_value> ,bsic: <bsic_value> ,dBm: <dBm_value> ,
<[mcc: <mcc_value> ,mnc: <mnc_value> ,lac: <lac_value> ,cellId:
<cellId> ,cellStatus: <cellStasus> ] or [SIB3 not available]>,
<[numArfcn: <num_afrcn> , arfcn: <list of arfcns> ] or [cell allocation empty]>,<[numChannels: <num_channel> ,array: <list of channels> ] or [SIB2 not available]>]
[…]
For non BCCH-Carrier:
[arfch: <arfcn_value> ,dBm: <dBm_value> ]
[…]
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CNSVS= <arfcn_index>
Execution Command
AT+CNSVS
Network survey end
OK
If BCCH-Carrier: arfcn: <arfcn_value> ,bsic: <bsic_value> ,dBm: <dBm_value> ,
<[mcc: <mcc_value> ,mnc: <mnc_value> ,lac: <lac_value> ,cellId:
<cellId> ,cellStatus: <cellStasus> ] or [SIB3 not available]>,
<[numArfcn: <num_afrcn> , arfcn: <list of arfcns> ] or [cell allocation empty]>,<[numChannels: <num_channel> ,array: <list of channels> ] or [SIB2 not available]>
OK
If non BCCH-Carrier: arfch: <arfcn_value> ,dBm: <dBm_value>
OK
+CNSVS: NOT IN GSM
OK
+CNSVS: arfcn index invalid
OK
ERROR
Responses
Network survey started…
For BCCH-Carrier:
[arfcn: <arfcn_value> ,bsic: <bsic_value> ,dBm: <dBm_value> ,
<[mcc: <mcc_value> ,mnc: <mnc_value> ,lac: <lac_value> ,cellId:
<cellId> ,cellStatus: <cellStasus> ] or [SIB3 not available]>,
<[numArfcn: <num_afrcn> , arfcn: <list of arfcns> ] or [cell allocation empty]>,<[numChannels: <num_channel> ,array: <list of channels> ] or [SIB2 not available]>]
[…]
For non BCCH-Carrier:
[arfch: <arfcn_value> ,dBm: <dBm_value> ]
[…]
Network survey end
OK
Defined values
<count> the count of arfcn.
<s> starting channel.
<e> ending channel.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<arfcn_value> carrier assigned radio channel (BCCH – Broadcast Control Channel).
<bsic_value> base station identification code.
<dBm_value> the value of dBm.
<mcc_value> mobile country code.
<mnc_value> mobile network code.
<lac_value> localization area code.
<cellId> cell identifier.
<cellStatus> cell status, this parameter indicates the following statuses:
- CELL_SUITABLE indicates the C0 is a suitable cell.
- CELL_LOW_PRIORITY indicates the cell is low priority based on the system information received.
- CELL_FORBIDDEN indicates the cell is forbidden.
- CELL_BARRED indicates the cell is barred based on the system information received.
- CELL_LOW_LEVEL indicates the cell RXLEV is low.
- CELL_OTHER indicates none of the above, e.g. exelusion timer running, no BCCH available etc.
<num_arfcn> number of valid channels
<list of arfcns> list of arfcns BCCH allocation and the total number is <num_arfcn>
<num_channel> number of valid channels
<list of channels> list of channels, and the total number is <num_channels>
<arfcn_index> the index of arfcn, and the minimum value is zero
Examples
AT+CNSVS
Network survey started...
For BCCH-Carrier: arfcn: 600,bsic: 54,dBm: -98,mcc: 460,mnc: 0,lac: 6180,cellId: 49443,cellStatus:
CELL_LOW_LEVEL, numArfcn: 6,arfcn: 518 521 542 547 574 600,numChannels: 25,array: 6 9 11
12 14 19 20 21 22 23 24 25 27 28 36 516 525 528 552 556 564 568 572 584 600
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
……
For non BCCH-Carrier: arfcn: 694,dBm: -94
……
Network survey end
OK
5.27
AT+CNSVN Network full band scan in numeric format
Description
This command is used to perform a quick survey through channels belonging to the band selected, starting from channel <s> to channel <e> . If parameters are omitted, a full band scan is performed.
After issuing the command, the information for every received BCCH(BCCH-Carrier and non
BCCH-Carrier) is reported in the format of string.
SIM PIN References
NO Vendor
Syntax
Write Command
AT+CNSVN= <s> , <e>
Responses
Network survey started…
If BCCH-Carrier:
[ <arfcn_value> , <bsic_value> , <dBm_value> ,<[ <mcc_value> ,
<mnc_value> , <lac_value> , <cellId> , <cellStasus> ] or [SIB3 not available]>, <[ <num_afrcn> , <list of arfcns> ] or [cell allocation empty]>,<[ <num_channel> , <list of channels> ] or [SIB2 not available]>]
[…]
If non BCCH-Carrier:
[ <arfcn_value> , <dBm_value> ]
[…]
Network survey end
OK
AT+CNSVN= <arfcn_index> If BCCH-Carrier:
<arfcn_value> , <bsic_value> , <dBm_value> ,<[ <mcc_value> ,
<mnc_value> , <lac_value> , <cellId> , <cellStasus> ] or [SIB3 not available]>, <[ <num_afrcn> , <list of arfcns> ] or [cell allocation empty]>,<[ <num_channel> , <list of channels> ] or [SIB2 not available]>
OK
If non BCCH-Carrier:
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Execution Command
AT+CNSVN
<arfcn_value> , <dBm_value>
OK
+CNSVN: NOT IN GSM
OK
+CNSVN: arfcn index invalid
OK
ERROR
Responses
Network survey started…
If BCCH-Carrier:
[ <arfcn_value> , <bsic_value> , <dBm_value> ,<[ <mcc_value> ,
<mnc_value> , <lac_value> , <cellId> , <cellStasus> ] or [SIB3 not available]>, <[ <num_afrcn> , <list of arfcns> ] or [cell allocation empty]>,<[ <num_channel> , <list of channels> ] or [SIB2 not available]>]
[…]
If non BCCH-Carrier:
[ <arfcn_value> , <dBm_value> ]
[…]
Network survey end
OK
Defined values
<count> the count of arfcn.
<s> starting channel.
<e> ending channel.
<arfcn_value> carrier assigned radio channel (BCCH – Broadcast Control Channel).
<bsic_value> base station identification code.
<dBm_value> the value of dBm.
<mcc_value> mobile country code.
<mnc_value> mobile network code.
<lac_value> localization area code.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<cellId> cell identifier.
<cellStatus> cell status, this parameter indicates the following statuses:
0 – Indicates the C0 is a suitable cell.
1 – Indicates the cell is low priority based on the system information received.
2 – Indicates the cell is forbidden.
3 – Indicates the cell is barred based on the system information received.
4 – Indicates the cell RXLEV is low.
5 – Indicates none of the above, e.g. exelusion timer running, no BCCH available etc
<num_arfcn> number of valid channels.
<list of arfcns> list arfcns BCCH allocation, and the total number is <num_arfcn> .
<num_channel> number of valid channels.
<list of channels> list channels, and the total number is <num_channels> .
<arfcn_index> the index of arfcn, and the minimum value is zero.
Examples
AT+CNSVN
Network survey started…
16,45,-82,460,0,6180,42545,0,5, 16 45 49 71 81,11, 11 12 14 16 19 20 21 22 24 26 27
……
694, -94
……
Network survey end
OK
5.28
AT+CNSVUS Network band scan by channels in string
Description
This command is used to perform a quick survey of user defined channels. It scans the given channels. The result format is in string format.
SIM PIN References
NO Vendor
Syntax
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
AT+CNSVUS= <ch1> ,[ <ch2
> ,[…[ <ch10> ]]]
Responses
Network survey started…
For BCCH-Carrier:
[arfcn: <arfcn_value> ,bsic: <bsic_value> ,dBm: <dBm_value> ,
<[mcc: <mcc_value> ,mnc: <mnc_value> ,lac: <lac_value> ,cellId:
<cellId> ,cellStatus: <cellStasus> ] or [SIB3 not available]>,
<[numArfcn: <num_afrcn> , arfcn: <list of arfcns> ] or [cell allocation empty]>,<[numChannels: <num_channel> ,array: <list of channels> ] or [SIB2 not available]>]
[…]
For non BCCH-Carrier:
[arfch: <arfcn_value> ,dBm: <dBm_value> ]
[…]
Network survey end
OK
+CNSVN: NOT IN GSM
OK
ERROR
Defined values
<chN> channel number(arfcn). It must be in an increasing order, and the range of “N” is from 1 to 10.
<arfcn_value> carrier assigned radio channel (BCCH – Broadcast Control Channel).
<bsic_value> base station identification code.
<dBm_value> the value of dBm.
<mcc_value> mobile country code.
<mnc_value> mobile network code.
<lac_value> localization area code.
<cellId> cell identifier.
<cellStatus> cell status, this parameter indicates the following statuses:
- CELL_SUITABLE indicates the C0 is a suitable cell.
- CELL_LOW_PRIORITY indicates the cell is low priority based on the system information received.
- CELL_FORBIDDEN indicates the cell is forbidden.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
- CELL_BARRED indicates the cell is barred based on the system information received.
- CELL_LOW_LEVEL indicates the cell RXLEV is low.
- CELL_OTHER indicates none of the above, e.g. exelusion timer running, no BCCH available etc.
<num_arfcn> number of valid channels.
<list of arfcns> list arfcns BCCH allocation, and the total number is <num_arfcn> .
<num_channel> number of valid channels.
<list of channels> list channels, and the total number is <num_channels> .
Examples
AT+CNSVUS=16,20,86,96,109
Network survey started...
For BCCH-Carrier: arfcn: 16,bsic: 45,dBm: -80,mcc: 460,mnc: 0,lac: 6180,cellId: 42545,cellStatus:CELL_SUITABLE, numArfcn: 5,arfcn: 16 45 49 71 81,numChannels: 11,array: 11 12 14 16 19 20 21 22 24 26 27
For non BCCH-Carrier: arfcn: 86,dBm: -97
Network survey end
OK
5.29
AT+CNSVUN Network band scan by channels in numeric
Description
This command is used to perform a quick survey of user defined channels. It scans the given channels. The result is reported in numeric format.
SIM PIN References
NO Vendor
Syntax
Write Command
AT+CNSVUN=<ch1>,[ <ch2
> ,[…[ <ch10> ]]]
Responses
Network survey started…
For BCCH-Carrier:
[ <arfcn_value> , <bsic_value> , <dBm_value> ,<[ <mcc_value> ,
<mnc_value> , <lac_value> , <cellId> , <cellStasus> ] or [SIB3 not available]>, <[ <num_afrcn> , <list of arfcns> ] or [cell allocation empty]>,<[ <num_channel> , <list of channels> ] or [SIB2 not
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set available]>]
[…]
For non BCCH-Carrier:
[ <arfcn_value> , <dBm_value> ]
[…]
Network survey end
OK
+CNSVN: NOT IN GSM
OK
ERROR
Defined values
<chN> channel number(arfcn). It must be in a increasing order, and the range of “N” is from 1 to 10.
<arfcn_value> carrier assigned radio channel (BCCH – Broadcast Control Channel).
<bsic_value> base station identification code.
<dBm_value> the value of dBm.
<mcc_value> mobile country code.
<mnc_value> mobile network code.
<lac_value> localization area code.
<cellId> cell identifier.
<cellStatus> cell status, this parameter indicates the following statuses:
0 – Indicates the C0 is a suitable cell.
1 – Indicates the cell is low priority based on the system information received.
2 – Indicates the cell is forbidden.
3 – Indicates the cell is barred based on the system information received.
4 – Indicates the cell RXLEV is low.
5 – Indicates none of the above, e.g. exelusion timer running, no BCCH available etc
<num_arfcn> number of valid channels.
<list of arfcns> list arfcns BCCH allocation, and the total number is <num_arfcn> .
<num_channel> number of valid channels.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<list of channels> list channels, and the total number is <num_channels> .
Examples
AT+CNSVUN=16,20,86,96,109
Network survey started...
14,51, -89, 460, 0, 6180, 41074,0, 8, 5 7 14 51 61 65 74 88, 24, 2 3 9 11 12 15 16 17 19 20 22 24 25
26 27 28 36 81 516 520 525 532 556 600
86, -97
Network survey end
OK
5.30
AT+CCGMDF Enable single mode in RAT balancing mode
Description
This command is used to enable or disable single mode in RAT balancing mode. This command supports SIM5320A only. The default setting of RAT balancing depends on EF-RAT, and usually it is “Dual Mode”. After calling AT+CCGMDF=1 and AT+CNMP=13 or 14, the mode can be changed to single mode.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CCGMDF=?
Read Command
AT+CCGMDF?
Write Command
AT+CCGMDF= <mode>
Responses
+CCGMDF: (0,1)
OK
Responses
+CCGMDF: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
Whether to enable or disable single mode in RAT balancing condition (mode depends on
AT+CNMP):
0 – Disable.
1 – Enable.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CCGMDF=1
OK
AT+CCGMDF?
+CCGMDF:0
OK
AT+CCGMDF=?
+CCGMDF:(0-1)
OK
5.31
AT+CPLMNPASS Manage PLMN filter password
Description
This command is used to manage password for AT+CPLMNWLIST.
Syntax
Write Command
AT+CPLMNPASS= <passwo rd> [, <new_password> ]
Responses
OK
ERROR
Defined values
<password>
The password for the module. Value field in string format, the maximum length is 8.
<new_password>
The new password for the module. Value field in string format, the maximum length is 8.
Examples
AT+CPLMNPASS= “”, “12345678”
OK
AT+CPLMNPASS= “12345678”, “111111”
OK
AT+CPLMNPASS=”111111”
OK
AT+CPLMNPASS=”111111”,””
OK
5.32
AT*CNTI Query Network Mode
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to query the network mode of the module.
SIM PIN References
YES Vendor
Syntax
Test Command
AT*CNTI=?
Read Command
AT*CNTI?
Write Command
AT*CNTI =
<CNTI_option>
Responses
*CNTI: (list of supported <CNTI_option> s)
OK
Responses
*CNTI: <CNTI_option> , <network_mode>
OK
Responses
*CNTI: <CNTI_option> , <network_mode>s
OK
ERROR
Defined values
<CNTI_option>
Network query option.
Value:
Query current
Query network
Query network
<network_mode> available the by module
The wireless access technologies separated by ‘,’. For some products, the HSDPA or HSUPA is not supported.
Value:
NONE
GSM
GPRS
EDGE
UMTS
HSDPA
HSUPA
Examples
AT*CNTI =1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
*CNTI: 1, UMTS
OK
AT*CNTI?
*CNTI: 1, GSM, GPRS
OK
5.33
AT+CELLLOCK Lock on specified 2G cell
Description
This command is used to lock on specified 2G cell
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CELLLOCK=?
Read Command
AT+CELLLOCK?
Execution Command
AT+CELLLOCK
Write Command
AT+CELLLOCK= <arfcn>
Responses
OK
Responses
+CELLLOCK: <arfcn> , <state>
OK
Responses
Set default value: 0,IDLE
OK
Responses
OK
[+CELLLOCKED]
ERROR
Defined values
<arfcn>
The arfcn of the cell. User can use AT+CCINFO to get it.
<state>
The state of the locking action
IDLE – no locking
LOCKING – trying to lock on the target cell.
LOCKED – already locked on the target cell.
Examples
AT+CELLLOCK=736
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CELLLOCKED
AT+CELLLOCK?
+CELLLOCK: 736, LOCKED
OK
AT+CELLLOCK=?
OK
5.34
AT+CLUCELL Lock on specified 3G cell
Description
This command is used to lock on specified 3G cell
SIM PIN References
NO Vendor
Syntax
Execution Command
AT+CLUCELL
Write Command
AT+CLUCELL= <Freq>,<PSC>
Responses
Set factory default: Disable frequency locking
OK
Responses
OK
ERROR
Defined values
<Freq>
Downlink frequency of cell. User can use AT+CPSI? command to get it.
<PSC>
Primary synchronization code of active set. User can use AT+CPSI? command to get it.
Examples
AT+CLUCELL=10663,279
OK
AT+CLUCELL
OK
5.35
AT+CLUARFCN Lock on specified frequency of 3G network
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to lock on a specified frequency of 3G network.
SIM PIN References
NO Vendor
Syntax
Execution Command
AT+CLUARFCN
Write Command
AT+CLUARFCN= <Freq>
Responses
Set factory default: Disable frequency locking
OK
Responses
OK
ERROR
Defined values
<Freq>
Downlink frequency of cell. User can use AT+CPSI? command to get it.
Examples
AT+CLUARFCN=10663
OK
AT+CLUARFCN
OK
5.36
AT+CRPAAO Set Network Searching Preference on Power up
Description
This command is used to set network searching preference on power up. This command only needs to be set once, it will take effect for ever.
Usually, when the module is power down normally, it will search the latest registered PLMN on next power up. But for some device, it sometimes does not power down normally, maybe just cut off the power, which may cause the module to search the network using unexpected order (like search the GSM first even the AT+CNAOP is set to WCDMA first. When set the AT+CRPAAO=1, it will try to search the network according to AT+CNAOP setting on power up.
SIM PIN References
YES Vendor
Syntax
Test Command Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CRPAAO=?
Read Command
AT+CRPAAO?
Write Command
AT+CRPAAO= <state>
+CRPAAO: (list of supported <state> s)
OK
Responses
+CRPAAO: <state>
OK
Responses
OK
ERROR
Defined values
<state>
The State of the setting:
0 – Disable.
1 – Enable.
Examples
AT+CRPAAO=1
OK
AT+CRPAAO?
+CRPAAO:1
OK
AT+CRPAAO=?
+CRPAAO: (0,1)
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
6 AT Commands for Call Control
6.1
AT+CVHU Voice hang up control
Description
Write command selects whether
or “ drop DTR ” shall cause a voice connection to be disconnected or not. By voice connection is also meant alternating mode calls that are currently in voice mode.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CVHU=?
Read Command
AT+CVHU?
Write Command
AT+CVHU= <mode>
Execution Command
AT+CVHU
Responses
+CVHU: (list of supported <mode> s)
OK
Responses
+CVHU: <mode>
OK
Responses
OK
ERROR
Responses
Set default value:
OK
Defined values
<mode>
0 – “ Drop DTR ” ignored but OK response given. ATH disconnects.
1 – “ Drop DTR ” and ATH ignored but OK response given.
Examples
AT+CVHU=0
OK
AT+CVHU?
+CVHU: 0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
6.2
AT+CHUP Hang up call
Description
This command is used to cancel voice calls. If there is no call, it will do nothing but OK response is given. After running AT+CHUP, multiple “VOICE CALL END: ” may be reported which relies on how many calls exist before calling this command.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CHUP=?
Execution Command
AT+CHUP
Responses
OK
Responses
VOICE CALL: END: <time>
[…
VOICE CALL: END: <time> ]
OK
No call:
OK
Defined values
<time>
Voice call connection time.
Format – HHMMSS (HH: hour, MM: minute, SS: second)
Examples
AT+CHUP
VOICE CALL:END: 000017
OK
6.3
AT+CBST Select bearer service type
Description
Write command selects the bearer service <name> with data rate <speed> , and the connection element <ce> to be used when data calls are originated. Values may also be used during mobile terminated data call setup, especially in case of single numbering scheme calls.
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
YES 3GPP TS 27.007
Syntax
Test Command
AT+CBST=?
Read Command
AT+CBST?
Write Command
AT+CBST=
<speed> [, <name> [, <ce> ]]
Execution Command
AT+CBST
Responses
+CBST: (list of supported <speed> s), (list of supported <name> s),
(list of supported <ce> s)
OK
Responses
+CBST: <speed> , <name> , <ce>
OK
Responses
OK
ERROR
Responses
Set default value:
OK
Defined values
<speed>
0 – autobauding(automatic selection of the speed; this setting is possible in case of 3.1 kHz modem and non-transparent service)
7 – 9600 bps (V.32)
80 – 28800 bps(V.110 or X.31 flag stuffing)
81 – 38400 bps(V.110 or X.31 flag stuffing)
83 – 56000 bps(V.110 or X.31 flag stuffing)
116 – 64000 bps(bit transparent)
134 – 64000 bps(multimedia)
<name>
0 – Asynchronous modem
1 – Synchronous modem
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<ce>
4 – data circuit asynchronous (RDI)
0 – transparent
1 – non-transparent
NOTE: If <speed> is set to 116 or 134, it is necessary that <name> is equal to 1 and <ce> is equal to 0.
Examples
AT+CBST=0,0,1
OK
AT+CBST?
+CBST:0,0,1
OK
6.4
AT+CRLP Radio link protocol
Description
Radio Link Protocol(RLP) parameters used when non-transparent data calls are originated may be altered with write command.
Read command returns current settings for each supported RLP version <verX> . Only RLP parameters applicable to the corresponding <verX> are returned.
Test command returns values supported by the TA as a compound value. If ME/TA supports several
RLP versions <verX> , the RLP parameter value ranges for each <verX> are returned in a separate line.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CRLP=?
Read Command
AT+CRLP?
Responses
+CRLP: (list of supported <iws> s), (list of supported <mws> s),
(list of supported <T1> s), (list of supported <N2> s) [, <ver1>
[,(list of supported <T4> s)]][<CR><LF>
+CRLP: (list of supported <iws> s), (list of supported <mws> s),
(list of supported <T1> s), (list of supported <N2> s) [, <ver2>
[,(list of supported <T4> s)]]
[...]]
OK
Responses
+CRLP: <iws> , <mws> , <T1> , <N2> [, <ver1> [, <T4> ]][<CR>
<LF>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
AT+CRLP= <iws>
[, <mws> [, <T1> [, <N2>
[, <ver> [, <T4> ]]]]]
Execution Command
AT+CRLP
+CRLP: <iws> , <mws> , <T1> , <N2> [, <ver2> [, <T4> ]]
[...]]
OK
Responses
OK
ERROR
Responses
OK
Defined values
<ver>, <verX>
RLP version number in integer format, and it can be 0, 1 or 2; when version indication is not present it shall equal 1.
<iws>
IWF to MS window size.
<mws>
MS to IWF window size.
<T1>
Acknowledgement timer.
<N2>
Retransmission attempts.
<T4>
Re-sequencing period in integer format.
NOTE: <T1> and <T4> are in units of 10 ms.
Examples
AT+CRLP?
+CRLP:61,61,48,6,0
+CRLP:61,61,48,6,1
+CRLP:240,240,52,6,2
OK
6.5
AT+CR Service reporting control
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write command controls whether or not intermediate result code “ +CR: <serv> ” is returned from the TA to the TE. If enabled, the intermediate result code is transmitted at the point during connect negotiation at which the TA has determined which speed and quality of service will be used, before any error control or data compression reports are transmitted, and before the intermediate result code CONNECT is transmitted.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CR=?
Read Command
AT+CR?
Write Command
AT+CR= <mode>
Execution Command
AT+CR
Responses
+CR: (list of supported <mode> s)
OK
Responses
+CR: <mode>
OK
Responses
OK
Responses
Set default value:
OK
Defined values
<mode>
0 – disables reporting
1 – enables reporting
<serv>
GPRS ] GPRS
The optional <L2P> proposes a layer 2 protocol to use between the MT and the TE.
Examples
AT+CR?
+CR:0
OK
AT+CR=1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
6.6
AT+CRC Cellular result codes
Description
Write command controls whether or not the extended format of incoming call indication or GPRS network request for PDP context activation is used. When enabled, an incoming call is indicated to the TE with unsolicited result code “+CRING: <type> ” instead of the normal RING.
Test command returns values supported by the TA as a compound value.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CRC=?
Read Command
AT+CRC?
Write Command
AT+CRC= <mode>
Execution Command
AT+CRC
Responses
+CRC: (list of supported <mode> s)
OK
Responses
+CRC: <mode>
OK
Responses
OK
Responses
Set default value:
OK
Defined values
<mode>
0 – disable extended format
1 – enable extended format
<type>
ASYNC asynchronous transparent
SYNC synchronous transparent
REL ASYNC asynchronous non-transparent
REL SYNC synchronous non-transparent
FAX facsimile
VOICE normal voice
VOICE/ XXX voice followed by data( XXX is ASYNC, SYNC, REL ASYNC or REL
SYNC)
ALT XXX alternating voice/data, voice first
ALT /VOICE alternating voice/data, data first
ALT FAX/VOICE alternating voice/fax, fax first
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
GPRS GPRS network request for PDP context activation
Examples
AT+CRC=1
OK
AT+CRC?
+CRC: 1
OK
6.7
AT+CLCC List current calls
Description
This command isused to return list of current calls of ME. If command succeeds but no calls are available, no information response is sent to TE.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CLCC=?
Read Command
AT+CLCC?
Write Command
AT+CLCC
= <n>
Execution Command
AT+CLCC
Responses
+CLCC: (list of supported <n> s)
OK
Responses
+CLCC: <n>
OK
Responses
OK
Responses
+CLCC: <id1> , <dir> , <stat> , <mode> , <mpty> [, <number> , <type> [, < alpha> ]][<CR><LF>
+CLCC: <id2> , <dir> , <stat> , <mode> , <mpty> [, <number> , <type> [,< alpha> ]]
[...]]
OK
ERROR
+CME ERROR: <err>
Defined values
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<n>
0 – Don’t report a list of current calls of ME automatically when the current call status changes.
1 – Report a list of current calls of ME automatically when the current call status changes.
<idX>
Integer type, call identification number, this number can be used in +CHLD command operations.
<dir>
0 – mobile originated (MO) call
1 – mobile terminated (MT) call
<stat>
State of the call:
0 – active
1 – held
2 – dialing (MO call)
3 – alerting (MO call)
4 – incoming (MT call)
5 – waiting (MT call)
6 – disconnect
<mode> bearer/teleservice:
0 – voice
1 – data
2 – fax
9 – unknown
<mpty>
0 – call is not one of multiparty (conference) call parties
1 – call is one of multiparty (conference) call parties
<number>
String type phone number in format specified by <type> .
<type>
Type of address octet in integer format;
128 – Restricted number type includes unknown type and format
145 – International number type
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
129 – Otherwise
<alpha>
String type alphanumeric representation of <number> corresponding to the entry found in phonebook; used character set should be the one selected with command Select TE Character Set
AT+CSCS .
Examples
ATD10011;
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CLCC
+CLCC: 1,0,0,0,0,"10011",129,"sm"
OK
RING (with incoming call)
AT+CLCC
+CLCC: 1,1,4,0,0,"02152063113",128,"gongsi"
OK
6.8
AT+CEER Extended error report
Description
Execution command causes the TA to return the information text <report> , which should offer the user of the TA an extended report of the reason for:
1 The failure in the last unsuccessful call setup(originating or answering) or in-call modification.
2 The last call release.
3 The last unsuccessful GPRS attach or unsuccessful PDP context activation.
4 The last GPRS detach or PDP context deactivation.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CEER=?
Execution Command
AT+CEER
Responses
OK
Responses
+CEER: <report>
OK
Defined values
<report>
Wrong information which is possibly occurred.
Examples
AT+CEER
+CEER: Invalid/incomplete number
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
6.9
AT+CCWA Call waiting
Description
This command allows control of the Call Waiting supplementary service. Activation, deactivation and status query are supported. When querying the status of a network service ( <mode> =2) the response line for 'not active' case ( <status> =0) should be returned only if service is not active for any <class> . Parameter <n> is used to disable/enable the presentation of an unsolicited result code
+CCWA: <number> , <type> , <class> to the TE when call waiting service is enabled. Command should be abortable when network is interrogated.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CCWA=?
Read Command
AT+CCWA?
Write Command
AT+CCWA=
<n> [, <mode> [, <class> ]]
Execution Command
AT+CCWA
Responses
+CCWA: (list of supported <n> s)
OK
Responses
+CCWA: <n>
OK
Responses
When <mode>=2 and command successful:
+CCWA: <status> , <class> [<CR><LF>
+CCWA: <status> , <class> [...]]
OK
ERROR
+CME ERROR: <err>
Responses
Set default value ( <n> =0):
OK
Defined values
<n>
Sets/shows the result code presentation status in the TA
0 – disable
1 – enable
<mode>
When <mode> parameter is not given, network is not interrogated:
0 – disable
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
1 – enable
2 – query status
<class>
It is a sum of integers each representing a class of information (default 7)
1 – voice (telephony)
2 – data (refers to all bearer services)
4 – fax (facsimile services)
7 – voice,data and fax(1+2+4)
8 – short message service
16 – data circuit sync
32 – data circuit async
64 – dedicated packet access
128 – dedicated PAD access
<status>
0 – not active
1 – active
<number>
String type phone number of calling address in format specified by <type> .
<type>
Type of address octet in integer format;
128 – Restricted number type includes unknown type and format
145 – International number type
129 – Otherwise
Examples
AT+CCWA=?
+CCWA:(0-1)
OK
AT+CCWA?
+CCWA: 0
OK
6.10
AT+CHLD Call related supplementary services
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command allows the control the following call related services:
1. A call can be temporarily disconnected from the ME but the connection is retained by the network.
2. Multiparty conversation (conference calls).
3. The served subscriber who has two calls (one held and the other either active or alerting) can connect the other parties and release the served subscriber's own connection.
Calls can be put on hold, recovered, released, added to conversation, and transferred. This is based on the GSM/UMTS supplementary services.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CHLD=?
Write Command
AT+CHLD= <n>
Execution Command
AT+CHLD
Default to <n>=2.
Responses
+CHLD: (list of supported <n> s)
OK
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<n>
0 – Terminate all held calls; or set User Determined User Busy for a waiting call
1 – Terminate all active calls and accept the other call (waiting call or held call)
1X – Terminate a specific call X
2 – Place all active calls on hold and accept the other call (waiting call or held call) as the active call
2X – Place all active calls except call X on hold
3 – Add the held call to the active calls
4 – Connect two calls and cut off the connection between users and them simultaneously
Examples
AT+CHLD=?
+CHLD: (0,1,1x,2,2x,3,4)
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
6.11
AT+CCFC Call forwarding number and conditions
Description
This command allows control of the call forwarding supplementary service. Registration, erasure, activation, deactivation, and status query are supported.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CCFC=?
Write Command
AT+CCFC= <reason> , <mode
> [, <number> [, <type> [, <clas s> [, <subaddr> [, <satype> [, <ti me> ]]]]]]
Responses
+CCFC: (list of supported <reason> s)
OK
Responses
When <mode>=2 and command successful:
+CCFC: <status> , <class1> [, <number> , <type>
[, <subaddr> , <satype> [, <time> ]]][<CR><LF>
+CCFC: <status> , <class2> [, <number> , <type>
[, <subaddr> , <satype> [, <time> ]]][...]]
OK
ERROR
+CME ERROR: <err>
Defined values
<reason>
0 – unconditional
1 – mobile busy
2 – no reply
3 – not reachable
4 – all call forwarding
5 – all conditional call forwarding
<mode>
0 – disable
1 – enable
2 – query status
3 – registration
4 – erasure
<number>
String type phone number of forwarding address in format specified by <type> .
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<type>
Type of address octet in integer format:
145 – dialing string <number> includes international access code character ‘+’
129 – otherwise
<subaddr>
String type sub address of format specified by <satype> .
<satype>
Type of sub address octet in integer format, default 128.
<classX>
It is a sum of integers each representing a class of information (default 7):
1 – voice (telephony)
2 – data (refers to all bearer services)
4 – fax (facsimile services)
16 – data circuit sync
32 – data circuit async
64 – dedicated packet access
128 – dedicated PAD access
255 – The value 255 covers all classes
<time>
1...30 – when "no reply" is enabled or queried, this gives the time in seconds to wait before call is forwarded, default value 20.
<status>
0 – not active
1 – active
Examples
AT+CCFC=?
+CCFC: (0,1,2,3,4,5)
OK
AT+CCFC=0,2
+CCFC: 0,255
OK
6.12
AT+CLIP Calling line identification presentation
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command refers to the GSM/UMTS supplementary service CLIP (Calling Line Identification
Presentation) that enables a called subscriber to get the calling line identity (CLI) of the calling party when receiving a mobile terminated call.
Write command enables or disables the presentation of the CLI at the TE. It has no effect on the execution of the supplementary service CLIP in the network.
When the presentation of the CLI at the TE is enabled (and calling subscriber allows), +CLIP:
<number> , <type> ,,[,[ <alpha> ][, <CLI validity> ]] response is returned after every RING (or
+CRING: <type> ; refer sub clause "Cellular result codes +CRC") result code sent from TA to TE. It is manufacturer specific if this response is used when normal voice call is answered.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CLIP=?
Read Command
AT+CLIP?
Write Command
AT+CLIP= <n>
Execution Command
AT+CLIP
Responses
+CLIP: (list of supported <n> s)
OK
Responses
+CLIP: <n> , <m>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
Set default value( <n> =0, <m> =0):
OK
Defined values
<n>
Parameter sets/shows the result code presentation status in the TA:
0 – disable
1 – enable
<m>
0 – CLIP not provisioned
1 – CLIP provisioned
2 – unknown (e.g. no network, etc.)
<number>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
String type phone number of calling address in format specified by <type> .
<type>
Type of address octet in integer format;
128 – Restricted number type includes unknown type and format
145 – International number type
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
129 – Otherwise
<alpha>
String type alphanumeric representation of <number> corresponding to the entry found in phone book.
<CLI validity>
0 – CLI valid
1 – CLI has been withheld by the originator
2 – CLI is not available due to interworking problems or limitations of originating network
Examples
AT+CLIP=1
OK
RING (with incoming call)
+CLIP: "02152063113",128,,,"gongsi",0
6.13
AT+CLIR Calling line identification restriction
Description
This command refers to CLIR-service that allows a calling subscriber to enable or disable the presentation of the CLI to the called party when originating a call.
Write command overrides the CLIR subscription (default is restricted or allowed) when temporary mode is provisioned as a default adjustment for all following outgoing calls. This adjustment can be revoked by using the opposite command.. If this command is used by a subscriber without provision of CLIR in permanent mode the network will act.
Read command gives the default adjustment for all outgoing calls (given in <n> ), and also triggers an interrogation of the provision status of the CLIR service (given in <m> ).
Test command returns values supported as a compound value.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CLIR =?
Read Command
AT+CLIR?
Write Command
AT+CLIR = <n>
+CLIR: (list of supported <n> s)
OK
Responses
+CLIR: <n> , <m>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<n>
0 – presentation indicator is used according to the subscription of the CLIR service
1 – CLIR invocation
2 – CLIR suppression
<m>
0 – CLIR not provisioned
1 – CLIR provisioned in permanent mode
2 – unknown (e.g. no network, etc.)
3 – CLIR temporary mode presentation restricted
4 – CLIR temporary mode presentation allowed
Examples
AT+CLIR=?
+CLIR:(0-2)
OK
6.14
AT+COLP Connected line identification presentation
Description
This command refers to the GSM/UMTS supplementary service COLP(Connected Line
Identification Presentation) that enables a calling subscriber to get the connected line identity
(COL) of the called party after setting up a mobile originated call. The command enables or disables the presentation of the COL at the TE. It has no effect on the execution of the supplementary service COLR in the network.
When enabled (and called subscriber allows), +COLP: <number> , <type> [, <subaddr> , <satype>
[, <alpha> ]] intermediate result code is returned from TA to TE before any +CR responses.
It is
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set manufacturer specific if this response is used when normal voice call is established.
When the AT+COLP=1 is set, any data input immediately after the launching of “ATDXXX;” will stop the execution of the ATD command, which may cancel the establishing of the call.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+COLP=?
Read Command
AT+COLP?
Write Command
AT+COLP = <n>
Execution Command
AT+COLP
Responses
+COLP: (list of supported <n> s)
OK
Responses
+COLP: <n> , <m>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
Set default value( <n> =0, <m> =0):
OK
Defined values
<n>
Parameter sets/shows the result code presentation status in the TA:
0 – disable
<m>
1 – enable
0 – COLP not provisioned
1 – COLP provisioned
2 – unknown (e.g. no network, etc.)
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+COLP?
+COLP: 1,0
OK
ATD10086;
VOICE CALL: BEGIN
+COLP: "10086",129,,,
OK
6.15
AT+VTS DTMF and tone generation
Description
This command allows the transmission of DTMF tones and arbitrary tones which cause the Mobile
Switching Center (MSC) to transmit tones to a remote subscriber. The command can only be used in voice mode of operation (active voice call).
NOTE: The END event of voice call will terminate the transmission of tones, and as an operator option, the tone may be ceased after a pre-determined time whether or not tone duration has been reached.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+VTS=?
Write Command
AT+VTS= <dtmf>
[, <duration> ]
AT+VTS= <dtmf-string>
Responses
+VTS: (list of supported <dtmf> s)
OK
Responses
OK
ERROR
Defined values
<dtmf>
A single ASCII character in the set 0-9, *, #, A, B, C, D.
<duration>
Tone duration in 1/10 seconds, from 0 to 255. This is interpreted as a DTMF tone of different duration from that mandated by the AT+VTD command, otherwise, the duration which be set the
AT+VTD command will be used for the tone ( <duration> is omitted).
<dtmf-string>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
A sequence of ASCII character in the set 0-9, *, #, A, B, C, D, and maximal length of the string is
29. The string must be enclosed in double quotes (“”), and separated by commas between the ASCII characters (e.g. “1,3,5,7,9,*”). Each of the tones with a duration which is set by the AT+VTD command.
Examples
AT+VTS=1
OK
AT+VTS=1,20
OK
AT+VTS=”1,3,5”
OK
AT+VTS=?
+VTS: (0-9,*,#,A,B,C,D)
OK
6.16
AT+VTD Tone duration
Description
This refers to an integer <n> that defines the length of tones emitted as a result of the AT+VTS command. A value different than zero causes a tone of duration <n>/ 10 seconds.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+VTD=?
Read Command
AT+VTD?
Responses
+VTD: (list of supported <n> s)
OK
Responses
+VTD: <n>
OK
Responses
OK
Write Command
AT+VTD= <n>
Defined values
<n>
Tone duration in integer format, from 0 to 255, and 0 is factory value.
0 Tone duration of every single tone is dependent on the network.
1…255 Tone duration of every single tone in 1/10 seconds.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+VTD=?
+VTD: (0-255)
OK
AT+VTD?
+VTD: 0
OK
AT+VTD=5
OK
6.17
AT+CSTA Select type of address
Description
Write command is used to select the type of number for further dialing commands (
) according to GSM/UMTS specifications.
Read command returns the current type of number.
Test command returns values supported by the Module as a compound value.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CSTA=?
Read Command
AT+CSTA?
Write Command
AT+CSTA= <type>
Execution Command
AT+CSTA
Responses
+CSTA:(list of supported <type> s)
OK
Responses
+CSTA: <type>
OK
Responses
OK
ERROR
Responses
OK
Defined values
<type>
Type of address octet in integer format:
145 – when dialling string includes international access code character “+”
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
129 – otherwise
NOTE: Because the type of address is automatically detected on the dial string of dialing
has really no effect.
Examples
AT+CSTA?
+CSTA: 129
OK
AT+CSTA=145
OK
6.18
AT+CMOD Call mode
Description
Write command selects the call mode of further dialing commands (
) or for next answering
). Mode can be either single or alternating.
Test command returns values supported by the TA as a compound value.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CMOD=?
Read Command
AT+CMOD?
Write Command
AT+CMOD= <mode>
Execution Command
AT+CMOD
Responses
+CMOD: (list of supported <mode> s)
OK
Responses
+CMOD: <mode>
OK
Responses
OK
ERROR
Responses
Set default value:
OK
Defined values
<mode>
0 – single mode(only supported)
NOTE: The value of <mode> shall be set to zero after a successfully completed alternating mode
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set call. It shall be set to zero also after a failed answering. The power-on, factory and user resets shall also set the value to zero. This reduces the possibility that alternating mode calls are originated or answered accidentally.
Examples
AT+CMOD?
+CMOD: 0
OK
AT+CMOD=0
OK
6.19
AT+VMUTE Speaker mute control
Description
This command is used to control the loudspeaker to mute and unmute during a voice call or a video call which is connected. If there is not a connected call, write command can’t be used.
When all calls are disconnected, the Module sets the subparameter as 0 automatically.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+VMUTE=?
Read Command
AT+VMUTE?
Write Command
AT+VMUTE= <mode>
Responses
+VMUTE: (list of supported <mode> s)
OK
Responses
+VMUTE: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
0 – mute off
1 – mute on
Examples
AT+VMUTE=1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+VMUTE?
+VMUTE:1
OK
6.20
AT+CMUT Microphone mute control
Description
This command is used to enable and disable the uplink voice muting during a voice call or a video call which is connected. If there is not a connected call, write command can’t be used.
When all calls are disconnected, the Module sets the subparameter as 0 automatically.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CMUT=?
Read Command
AT+CMUT?
Write Command
AT+CMUT= <mode>
Responses
+CMUT: (list of supported <mode> s)
OK
Responses
+CMUT: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
0 – mute off
1 – mute on
Examples
AT+CMUT=1
OK
AT+CMUT?
+CMUT: 1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
6.21
AT+CALM Alert sound mode
Description
This command is used to select the general alert sound mode of the device. If silent mode is selected then incoming calls will not generate alerting sounds but only the unsolicited indications
RING or +CRING. The value of <mode> will be saved to nonvolatile memory after write command is executed.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CALM=?
Read Command
AT+CALM?
Write Command
AT+CALM= <mode>
Responses
+CALM: (list of supported <mode> s)
OK
Responses
+CALM: <mode>
OK
Responses
OK
Defined values
<mode>
0 – normal mode (factory value)
1 – silent mode; no sound will be generated by the device
Examples
AT+CALM=0
OK
AT+CALM?
+CALM: 0
OK
6.22
AT+CRSL Ringer sound level
Description
This command is used to select the incoming call ringer sound level of the device. The value of
<level> will be saved to nonvolatile memory after write command is executed.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CRSL=?
Read Command
AT+CRSL?
Write Command
AT+CRSL= <level>
Responses
+CRSL: (list of supported <level> s)
OK
Responses
+CRSL: <level>
OK
Responses
OK
Defined values
<level>
Integer type value which represents the incoming call ringer sound level. The range is from 0 to 8, and 0 represents the lowest level, 2 is default factory value.
NOTE: <level> is nonvolatile, and it is stored when restart.
Examples
AT+CRSL=2
OK
AT+CRSL?
+CRSL:2
OK
6.23
AT+CODEC Set audio codec mode
Description
The command is used to configure audio codec mode.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CODEC=?
Responses
+CODEC: (list of supported <g_codec> s), (list of supported
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+CODEC?
Write Command
AT+CODEC= <g_codec> , < w_codec>
Execution Command
AT+CODEC
<w_codec> s)
OK
Responses
+CODEC: <g_codec> , <w_codec>
OK
Responses
OK
ERROR
Responses
Set default value(31,7)
OK
Defined values
<g_codec>
1~63 – Sum of integers each representing a specific codec mode, default value is 31.
1 – GSM FR
2 – GSM HR
4 – GSM EFR
8 – GSM FR AMR
16 – GSM HR AMR
32 – GSM FR AMR-WB
<w_codec>
1~7 – Sum of integers each representing a specific codec mode.,default value is 7.
1 – UMTS AMR
2 – UMTS AMR2
4 – UMTS AMR-WB
Examples
AT+CODEC=?
+CODEC: (1-63),( 1-7)
OK
AT+CODEC?
+CODEC: 63,7
OK
AT+AUTOCSQ=31,7
OK
6.24
AT+CVOC Get the current vocoder capability in a call
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to get the current vocoder capability in a call.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CVOC=?
Execution Command
AT+CVOC
Responses
OK
Responses
+CVOC : <voc> , <amr_mode> , <DTX> , <SCR>
OK
Defined values
<voc>
0x100 – AMR codec
0x200 – GSM EFR codec
0x400 – GSM Full rate codec
0x800 – GSM Half rate codec
0x1000000 – AMR-WB vocoder
Other values is reserved
<amr_mode>
0 – 4.75kbit/s AMR
1 – 5.15kbit/s AMR
2 – 5.9kbit/s AMR
3 – 6.7kbit/s AMR
4 – 7.4kbit/s AMR
5 – 7.95kbit/s AMR
6 – 10.2kbit/s AMR
7 – 12.2kbit/s AMR
8 – 6.60kbit/s AMR-WB
9 – 8.85kbit/s AMR-WB
10 – 12.65kbit/s AMR-WB
11 – 14.25kbit/s AMR-WB
12 – 15.58kbit/s AMR-WB
13 – 18.25kbit/s AMR-WB
14 – 19.58kbit/s AMR-WB
15 – 23.05kbit/s AMR-WB
16 – 23.85kbit/s AMR-WB
17 – undefined
<DTX>
0 – Disable encoder DTX mode
1 – Enable encoder DTX mode
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<SCR>
0 – Disable encoder SCR mode
1 – Enable encoder SCR mode
Examples
AT+CVOC
+CVOC: 0x200,17,0,0
OK
AT+CVOC
+CVOC: 0x100,7,0,0
OK
6.25
AT+MORING Enable or disable report MO ring URC
Description
This command is used to enable or disable report MO ring URC
SIM PIN References
NO Vendor
Syntax
Test Command
AT+MORING=?
Read Command
AT+MORING?
Write Command
AT+MORING= <mode>
Defined values
<mode>
Enable or disable report MO ring URC:
0 – disable
1 – enable.
Examples
AT+MORING=1
OK
Responses
+MORING: (0-1)
OK
Responses
+ MORING: <mode>
OK
Responses
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+MORING?
+MORING:1
OK
AT+MORING=?
+MORING: (0-1)
OK
6.26
AT+DDET Enable or disable RX DTMF detection
Description
This command is used to enable or disable RX DTMF detection.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+DDET=?
Read Command
AT+DDET?
Write Command
AT+DDET= <mode>
Responses
+DDET: (0,1)
OK
Responses
+DDET: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
Enable or disable RX DTMF detection:
0 – Disable.
1 – Enable.
Examples
AT+DDET=0
OK
AT+DDET?
+DDET:0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+DDET=?
+DDET:(0,1)
OK
6.27
AT+DDPARAM Configure DTMF detection parameters
Description
This command is used to configure DTMF detection parameters.
SIM PIN References
NO Vendor
Syntax
Write Command
AT+DDPARAM= <mode>[,
<notone_time>[,<threshold_t one>,<threshold_notone>,<t hreshold_forward_twist>,<th reshold_reverse_twist>,<thre shold_row_peakratio>,<thres hold_col_peakratio>],<thres hold_gain>]]
Responses
+DDPARAM: (list of supported <mode> s),(list of supported
<notone_time> s)[,(list of supported <threshold_tone> s),(list of supported <threshold_notone> s),(list of supported
<threshold_forward_twist> s),(list of supported
<threshold_reverse_twist> s),(list of supported < threshold_row_peakratio> s),(list of supported < threshold_col_peakratio > s),(list of supported <threshold_gain> s)]
OK
ERROR
Defined values
<mode>
DTMF detection mode.
0 – this mode support configuring <notone_time> only, and does not support AMR-WB voice call.
1 – this mode support configuring all parameters, and supports AMR-WB voice call.
<notone_time>
The no-tone duration time in microsecond. If the energy of a tone is less than <threshold_notone> , and the duration is more than <notone_time> , the tone may detect as a DTMF char when it’s energy is more than <threshold_tone> , otherwise the tone will not be detected, The scope is 20ms ~ 60S, the default value is 60ms.
<threshold_tone>
The DTMF tone energy threshold, if the energy of a tone is less than this number, the tone will not be detected. The scope is 0 ~ 32768, the default value is 2800.
<threshold_notone>
The no-tone energy threshold, if the energy of a tone is less than this number, the state machine will
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set treated as no tone status. The scope is 0 ~ 32768, the default value is 300.
<threshold_forward_twist>
The forward twist factor, it’s used when the energy in the high band frequency is higher than low band frequency. The DTMF tone is detected only if the energy of tone in the high band frequency less than low band frequency multiple by <threshold_forward_twist> *32768/10000. The scope is 0
~10000, the default value is 800.
<threshold_reverse_twist>
The reverse twist factor, it’s used when the energy in the low band frequency is higher than high band frequency. The DTMF tone is detected only if the energy of tone in the high band frequency less than low band frequency multiple by <threshold_reverse_twist> *32768/10000. The scope is 0
~10000, the default value is 800.
<threshold_row_peak_ratio>
The high frequency band’s relative energy peak ratio. The ratio is < threshold_row_peak_ratio> *32768/10000. The DTMF tone is detected only if the ratio is more than this value. The scope is 0 ~10000, the default value is 5000.
<threshold_col_peak_ratio>
The low frequency band’s relative energy peak ratio. The ratio is < threshold_col_peak_ratio> *32768/10000. The DTMF tone is detected only if the ratio is more than this value. The scope is 0 ~10000, the default value is 5000.
<threshold_gain>
The gain control threshold. The sample is adjusted when total sum is less than this value. The scope is 0 ~ 200, the default value is 85.
Examples
AT+DDPARAM=0,120
OK
AT+DDPARAM=1,100,2800,300,800,800,5000,5000,85
OK
6.28
AT+CFBDMTCALL Forbid new incoming voice call
Description
This command is set whether or not forbid new incoming voice call.
SIM PIN References
YES Vendor
Syntax
Test Command Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CFBDMTCALL=?
Read Command
AT+CFBDMTCALL?
Write Command
AT+ CFBDMTCALL
= <mode>
+CFBDMTCALL: (0,1)
OK
Responses
+CFBDMTCALL: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
The mode of forbidding new incoming voice call:
0 – Not forbidden.
1 – Forbidden.
Examples
AT+CFBDMTCALL=1
OK
6.29
AT+CMUTW Mute call waiting sound for voice call
Description
This command is set whether or not mute call waiting sound for voice call.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMUTW=?
Read Command
AT+CMUTW?
Write Command
AT+ CMUTW = <mode>
Responses
+CMUTW: (0,1)
OK
Responses
+CMUTW: <mode>
OK
Responses
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<mode>
The mode of muting call waiting sound for voice call:
0 – Not mute.
1 – Mute.
Examples
AT+CMUTW=1
OK
SIM5310_ATC_V2.00 10/15/2015
7 AT Commands for SMS
7.1
AT+CSMS Select message service
Description
This command is used to select messaging service <service> .
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CSMS=?
Read Command
AT+CSMS?
Write Command
AT+CSMS= <service>
Responses
+CSMS: (list of supported <service> s)
OK
Responses
+CSMS: <service> , <mt> , <mo> , <bm>
OK
Responses
+CSMS: <mt> , <mo> , <bm>
OK
ERROR
+CMS ERROR: <err>
Defined values
<service>
0 – SMS at command is compatible with GSM phase 2.
1 – SMS at command is compatible with GSM phase 2+.
<mt>
Mobile terminated messages:
0 – type not supported.
1 – type supported.
<mo>
Mobile originated messages:
0 – type not supported.
1 – type supported.
<bm>
Broadcast type messages:
SIM5310 AT Command Set
0 – type not supported.
1 – type supported.
Examples
AT+CSMS=0
+CSMS:1,1,1
OK
AT+CSMS?
+CSMS:0,1,1,1
OK
AT+CSMS=?
+CSMS:(0-1)
OK
7.2
AT+CPMS Preferred message storage
Description
This command is used to select memory storages <mem1> , <mem2> and <mem3> to be used for reading, writing, etc.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CPMS=?
Read Command
AT+CPMS?
Write Command
AT+CPMS= <mem1>
[, <mem2> [, <mem3> ]]
Responses
+CPMS: (list of supported <mem1> s), (list of supported
<mem2> s), (list of supported <mem3> s)
OK
Responses
+CPMS: <mem1> , <used1> , <total1 >, <mem2> , <used2> , <total2> ,
<mem3> , <used3> , <total3>
OK
ERROR
+CMS ERROR: <err>
Responses
+CPMS: <used1> , <total1> , <used2> , <total2> , <used3> , <total3>
OK
ERROR
+CMS ERROR:
<err>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<mem1>
String type, memory from which messages are read and deleted (commands List Messages
AT+CMGL , Read Message AT+CMGR and Delete Message AT+CMGD ).
“ME” and “MT” FLASH message storage
“SM” SIM message storage
“SR” Status report storage
<mem2>
String type, memory to which writing and sending operations are made (commands Send Message from Storage AT+CMSS and Write Message to Memory AT+CMGW ).
“ME” and “MT” FLASH message storage
“SM” SIM message storage
“SR” Status report storage
<mem3>
String type, memory to which received SMS is preferred to be stored (unless forwarded directly to
TE; refer command New Message Indications AT+CNMI ).
“ME” FLASH message storage
“SM” SIM message storage
<usedX>
Integer type, number of messages currently in <memX> .
<totalX>
Integer type, total number of message locations in <memX> .
Examples
AT+CPMS=?
+CPMS: ("ME","MT","SM","SR"),("ME","MT","SM","SR"),("ME","SM")
OK
AT+CPMS?
+CPMS:"ME", 0, 23,"ME", 0, 23,"ME", 0, 23
OK
AT+CPMS="SM","SM","SM"
+CPMS:3,40,3,40,3,40
OK
7.3
AT+CMGF Select SMS message format
Description
This command is used to specify the input and output format of the short messages.
SIM PIN References
YES 3GPP TS 27.005
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Test Command
AT+CMGF=?
Read Command
AT+CMGF?
Write Command
AT+CMGF= <mode>
Execution Command
AT+CMGF
Defined values
<mode>
0 – PDU mode
1 – Text mode
Examples
AT+CMGF?
+CMGF: 0
OK
AT+CMGF=?
+CMGF: (0-1)
OK
AT+CMGF=1
OK
7.4
AT+CSCA SMS service centre address
Description
This command is used to update the SMSC address, through which mobile originated SMS are transmitted.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Responses
+CMGF: (list of supported <mode> s)
OK
Responses
+CMGF: <mode>
OK
Responses
OK
Responses
Set default value ( <mode> =0):
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Test Command
AT+CSCA=?
Read Command
AT+CSCA?
Responses
OK
Responses
+CSCA: <sca> , <tosca>
OK
Write Command Responses
AT+CSCA= <sca> [, <tosca> ] OK
Defined values
<sca>
Service Center Address , value field in string format, BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set (refer to command
) , type of address given by <tosca> .
<tosca>
SC address Type-of-Address octet in integer format, when first character of <sca> is + (IRA 43) default is 145, otherwise default is 129.
Examples
AT+CSCA="+8613012345678"
OK
AT+CSCA?
+CSCA: "+8613010314500", 145
OK
7.5
AT+CSCB Select cell broadcast message indication
Description
The test command returns the supported <mode> s as a compound value.
The read command displays the accepted message types.
Depending on the <mode> parameter, the write command adds or deletes the message types accepted.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CSCB=?
Responses
+CSCB: (list of supported <mode> s)
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+CSCB?
ERROR
Responses
+CSCB: <mode> , <mids> , <dcss>
OK
ERROR
Write Command
AT+CSCB=
<mode> [, <mides>[ , <dcss>] ]
Responses
OK
ERROR
+CMS ERROR: <err>
Defined values
<mode>
0 – message types specified in <mids> and <dcss> are accepted.
1 – message types specified in <mids> and <dcss> are not accepted.
<mides>
String type; all different possible combinations of CBM message identifiers.
<dcss>
String type; all different possible combinations of CBM data coding schemes(default is empty string)
Examples
AT+CSCB=?
+CSCB: (0-1)
OK
AT+CSCB=0,”15-17,50,86”,””
OK
7.6
AT+CSMP Set text mode parameters
Description
This command is used to select values for additional parameters needed when SM is sent to the network or placed in storage when text format message mode is selected.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CSMP=?
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+CSMP?
Write Command
AT+CSMP=
[<fo> [, <vp> [, <pid> [, <dcs> ]]
]]
Responses
+CSMP: <fo> , <vp> , <pid> , <dcs>
OK
Responses
OK
Defined values
<fo>
Depending on the Command or result code: first octet of GSM 03.40 SMS-DELIVER,
SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format. SMS status report is supported under text mode if <fo> is set to 49.
<vp>
Depending on SMS-SUBMIT <fo> setting: GSM 03.40,TP-Validity-Period either in integer format
(default 167), in time-string format, or if is supported, in enhanced format (hexadecimal coded string with quotes), ( <vp> is in range 0... 255).
<pid>
GSM 03.40 TP-Protocol-Identifier in integer format (default 0).
<dcs>
GSM 03.38 SMS Data Coding Scheme (default 0), or Cell Broadcast Data Coding Scheme in integer format depending on the command or result code.
Examples
AT+CSMP=17,23,64,244
OK
7.7
AT+CSDH Show text mode parameters
Description
This command is used to control whether detailed header information is shown in text mode result codes.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CSDH=?
Responses
+CSDH: (list of supported <show> s)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+CSDH?
Write Command
AT+CSDH= <show>
Execution Command
AT+CSDH
OK
Responses
+CSDH: <show>
OK
Responses
OK
Responses
Set default value ( <show> =0):
OK
Defined values
<show>
0 – do not show header values defined in commands AT+CSCA and AT+CSMP ( <sca> ,
<tosca> , <fo> , <vp> , <pid> and <dcs> ) nor <length> , <toda> or <tooa> in +CMT ,
AT+CMGL , AT+CMGR result codes for SMS-DELIVERs and SMS-SUBMITs in text mode; for SMS-COMMANDs in AT+CMGR result code, do not show <pid> , <mn> , <da> , <toda> ,
<length> or <data>
1 – show the values in result codes
Examples
AT+CSDH?
+CSDH: 0
OK
AT+CSDH=1
OK
7.8
AT+CNMA New message acknowledgement to ME/TA
Description
This command is used to confirm successful receipt of a new message (SMS-DELIVER or
SMS-STATUSREPORT) routed directly to the TE. If ME does not receive acknowledgement within required time (network timeout), it will send RP-ERROR to the network.
NOTE: The execute / write command shall only be used when AT+CSMS parameter <service> equals 1 (= phase 2+) and appropriate URC has been issued by the module, i.e.:
<+CMT> for <mt> =2 incoming message classes 0, 1, 3 and none;
<+CMT> for <mt> =3 incoming message classes 0 and 3;
<+CDS> for <ds> =1.
SIM PIN References
YES 3GPP TS 27.005
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Test Command
AT+CNMA=?
Write Command
AT+CNMA= <n>
Execution Command
AT+CNMA
Responses if text mode( AT+CMGF =1):
OK if PDU mode ( AT+CMGF =0):
+CNMA: (list of supported <n> s)
OK
Responses
OK
ERROR
+CMS ERROR: <err>
Responses
OK
ERROR
+CMS ERROR: <err>
Defined values
<n>
Parameter required only for PDU mode.
0 – Command operates similarly as execution command in text mode.
1 – Send positive (RP-ACK) acknowledgement to the network. Accepted only in PDU mode.
2 – Send negative (RP-ERROR) acknowledgement to the network. Accepted only in PDU mode.
Examples
AT+CNMI=1,2,0,0,0
OK
+CMT:”1380022xxxx”,”02/04/03,11 :06 :38”,129,7,0<CR><LF>
Testing
(receive new short message)
AT+CNMA (send ACK to the network)
OK
AT+CNMA
+CMS ERROR : 340
(the second time return error, it needs ACK only once)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
7.9
AT+CNMI New message indications to TE
Description
This command is used to select the procedure how receiving of new messages from the network is indicated to the TE when TE is active, e.g. DTR signal is ON. If TE is inactive (e.g. DTR signal is
OFF).
If set <mt> = 2, <mt> = 3 or <ds> = 1, make sure <mode> = 1, otherwise it will return error.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CNMI=?
Read Command
AT+CNMI?
Write Command
AT+CNMI= <mode> [, <mt> [,
<bm> [, <ds> [, <bfr> ]]]]
Execution Command
AT+CNMI
Responses
+CNMI: (list of supported <mode> s),(list of supported <mt> s),(list of supported <bm> s),(list of supported <ds> s),(list of supported
<bfr> s)
OK
Responses
+CNMI: <mode> , <mt> , <bm> , <ds> , <bfr>
OK
Responses
OK
ERROR
+CMS ERROR: <err>
Responses
Set default value:
OK
Defined values
<mode>
0 – Buffer unsolicited result codes in the TA. If TA result code buffer is full, indications can be buffered in some other place or the oldest indications may be discarded and replaced with the new received indications.
1 – Discard indication and reject new received message unsolicited result codes when
TA-TE link is reserved (e.g. in on-line data mode). Otherwise forward them directly to the TE.
2 – Buffer unsolicited result codes in the TA when TA-TE link is reserved (e.g. in on-line data mode) and flush them to the TE after reservation. Otherwise forward them directly to the TE.
<mt>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
The rules for storing received SMS depend on its data coding scheme, preferred memory storage
( AT+CPMS ) setting and this value:
0 – No SMS-DELIVER indications are routed to the TE.
1 – If SMS-DELIVER is stored into ME/TA, indication of the memory location is routed to the TE using unsolicited result code: +CMTI: <mem3> , <index> .
2 – SMS-DELIVERs (except class 2 messages and messages in the message waiting indication group (store message)) are routed directly to the TE using unsolicited result code:
+CMT:[ <alpha> ], <length> <CR><LF> <pdu> (PDU mode enabled); or
+CMT: <oa> ,[ <alpha> ], <scts> [, <tooa> , <fo> , <pid> , <dcs> , <sca> , <tosca> , <length> ]
<CR> <LF> <data>
(text mode enabled, about parameters in italics, refer command Show Text Mode
Parameters AT+CSDH ).
3 – Class 3 SMS-DELIVERs are routed directly to TE using unsolicited result codes defined in <mt> =2. Messages of other data coding schemes result in indication as defined in <mt> =1.
<bm>
The rules for storing received CBMs depend on its data coding scheme, the setting of Select CBM
Types ( AT+CSCB ) and this value:
0 – No CBM indications are routed to the TE.
2 – New CBMs are routed directly to the TE using unsolicited result code:
+CBM: <length> <CR><LF> <pdu> (PDU mode enabled); or
+CBM: <sn> , <mid> , <dcs> , <page> , <pages> <CR><LF> <data> (text mode enabled)
<ds>
0 – No SMS-STATUS-REPORTs are routed to the TE.
1 – SMS-STATUS-REPORTs are routed to the TE using unsolicited result code:
+CDS: <length> <CR><LF> <pdu> (PDU mode enabled); or
+CDS: <fo> , <mr> ,[ <ra> ],[ <tora> ], <scts> , <dt> , <st> (text mode enabled)
2 – If SMS-STATUS-REPORT is stored into ME/TA, indication of the memory location is routed to the TE using unsolicited result code: +CDSI: <mem3> , <index> .
<bfr>
0 – TA buffer of unsolicited result codes defined within this command is flushed to the TE when <mode> 1 to 3 is entered (OK response shall be given before flushing the codes).
1 – TA buffer of unsolicited result codes defined within this command is cleared when
<mode> 1 to 3 is entered.
Examples
AT+CNMI?
+CNMI: 0,0,0,0,0
OK
AT+CNMI=?
+CNMI: (0,1,2),(0,1,2,3),(0,2),(0,1,2),(0,1)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CNMI=2,1 (unsolicited result codes after received messages.)
OK
7.10
AT+CGSMS Select service for MO SMS messages
Description
The write command is used to specify the service or service preference that the MT will use to send
MO SMS messages.
The test command is used for requesting information on which services and service preferences can be set by using the AT+CGSMS write command
The read command returns the currently selected service or service preference.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGSMS=?
Read Command
AT+CGSMS?
Write Command
AT+CGSMS= <service>
Responses
+CGSMS: (list of supported <service> s)
OK
Responses
+CGSMS: <service>
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<service>
A numeric parameter which indicates the service or service preference to be used
0 – GPRS(value is not really supported and is internally mapped to 2)
1 – circuit switched(value is not really supported and is internally mapped to 3)
2 – GPRS preferred (use circuit switched if GPRS not available)
3 – circuit switched preferred (use GPRS if circuit switched not available)
Examples
AT+CGSMS?
+CGSMS: 3
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CGSMS=?
+CGSMS: (0-3)
OK
7.11
AT+CMGL List SMS messages from preferred store
Description
This command is used to return messages with status value <stat> from message storage <mem1> to the TE.
If the status of the message is 'received unread', the status in the storage changes to 'received read'.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CMGL=?
Write Command
AT+CMGL= <stat>
Responses
+CMGL: (list of supported <stat> s)
OK
Responses
If text mode (
AT+CMGF =1), command successful and SMS-S
UBMITs and/or SMS-DELIVERs:
+CMGL: <index> , <stat> , <oa> / <da> ,[ <alpha> ],[ <scts> ][, <tooa> / <t oda> , <fo> , <pid> , <dcs> , <sca> , <tosca> , <length> ]<CR><LF> <data
> [<CR><LF>
+CMGL: <index> , <stat> , <oa> / <da> ,[ <alpha> ],[ <scts> ][, <tooa> / <t oda> , <fo> , <pid> , <dcs> , <sca> , <tosca> , <length> ]<CR><LF> <data
> [...]]
OK
If text mode (
AT+CMGF =1), command successful and SMS-
STATUS-REPORTs:
+CMGL: <index> , <stat> , <fo> , <mr> ,[ <ra> ],[ <tora> ], <scts> , <dt> , <s t> [<CR><LF>
+CMGL: <index> , <stat> , <fo> , <mr> ,[ <ra> ],[ <tora> ], <scts> , <dt> , <s t> [...]]
OK
If text mode (
AT+CMGF =1), command successful and SMS-
COMMANDs:
+CMGL: <index> , <stat> , <fo> , <ct> [<CR><LF>
+CMGL: <index> , <stat> , <fo> , <ct> [...]]
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
If text mode (
AT+CMGF =1), command successful and CBM
storage:
+CMGL: <index> , <stat> , <sn> , <mid> , <page> , <pages>
<CR><LF> <data> [<CR><LF>
+CMGL: <index> , <stat> , <sn> , <mid> , <page> , <pages>
<CR><LF> <data> [...]]
OK
If PDU mode ( AT+CMGF =0) and Command successful:
+CMGL: <index> , <stat> ,[ <alpha> ], <length> <CR><LF> <pdu> [<C
R><LF>
+CMGL: <index> , <stat> ,[ <alpha> ], <length> <CR><LF> <pdu>
[…]]
OK
+CMS ERROR: <err>
Defined values
<stat>
1. Text Mode:
"REC UNREAD" received unread message (i.e. new message)
"REC READ" received read message
"STO UNSENT" stored unsent message
"STO SENT" stored sent message
2. PDU Mode:
0 – received unread message (i.e. new message)
1 – received read message
2 – stored unsent message
3 – stored sent message
4 – all messages
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tooa> .
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda> .
<alpha>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
String type alphanumeric representation of <da> or <oa> corresponding to the entry found in MT phonebook; implementation of this feature is manufacturer specific; used character set should be the one selected with command Select TE Character Set AT+CSCS .
<scts>
TP-Service-Centre-Time-Stamp in time-string format (refer <dt> ).
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda> ).
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length>
Integer type value indicating in the text mode ( AT+CMGF =1) the length of the message body
<data> in characters; or in PDU mode ( AT+CMGF =0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length)
<data>
In the case of SMS: TP-User-Data in text mode responses; format:
1. If <dcs> indicates that GSM 7 bit default alphabet is used and <fo> indicates that
TP-User-Data-Header-Indication is not set: a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current TE character set. b. If TE character set is "HEX": ME/TA converts each 7-bit character of GSM 7 bit default alphabet into two IRA character long hexadecimal numbers. (e.g. character
Π
(GSM 7 bit default alphabet 23) is presented as 17 (IRA 49 and 55))
2. If <dcs> indicates that 8-bit or UCS2 data coding scheme is used, or <fo> indicates that
TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA character long hexadecimal numbers. (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65))
3. If <dcs> indicates that GSM 7 bit default alphabet is used: a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current TE character set.
<fo> b. If TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7 bit default alphabet into two IRA character long hexadecimal numbers.
4. If <dcs> indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each
8-bit octet into two IRA character long hexadecimal numbers.
Depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER,
SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format. SMS status report is supported under text mode if <fo> is set to 49.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<ra>
Recipient Address
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
GSM 03.40 TP-Recipient-Address Address-Value field in string format;BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set(refer to command AT+CSCS );type of address given by <tora>
<tora>
Type of Recipient Address
GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda> )
<dt>
Discharge Time
GSM 03.40 TP-Discharge-Time in time-string format:”yy/MM/dd,hh:mm:ss+zz”,where characters indicate year (two last digits),month,day,hour,minutes,seconds and time zone.
<st>
Status
GSM 03.40 TP-Status in integer format
0…255
<ct>
Command Type
GSM 03.40 TP-Command-Type in integer format
0…255
<sn>
Serial Number
GSM 03.41 CBM Serial Number in integer format
<mid>
Message Identifier
GSM 03.41 CBM Message Identifier in integer format
<page>
Page Parameter
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
<pages>
Page Parameter
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
<pdu>
In the case of SMS: SC address followed by TPDU in hexadecimal format: ME/TA converts each octet of TP data unit into two IRA character long hexadecimal numbers. (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)).
Examples
AT+CMGL=?
+CMGL: ("REC UNREAD","REC READ","STO UNSENT","STO SENT","ALL")
OK
AT+CMGL="ALL"
+CMGL: 1,"STO UNSENT","+10011",,,145,4
Hello World
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
7.12
AT+CMGR Read message
Description
This command is used to return message with location value <index> from message storage
<mem1> to the TE.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CMGR=?
Write Command
AT+CMGR= <index>
Responses
OK
Responses
If text mode ( AT+CMGF =1), command successful and SMS-
DELIVER:
+CMGR: <stat> , <oa> ,[ <alpha> ], <scts> [, <tooa> , <fo> , <pid> , <dcs> ,
<sca> , <tosca> , <length> ]<CR><LF> <data>
OK
If text mode ( AT+CMGF =1), command successful and SMS-
SUBMIT:
+CMGR: <stat> , <da> ,[ <alpha> ][, <toda> , <fo> , <pid> , <dcs> ,[ <vp> ],
<sca> , <tosca> , <length> ]<CR><LF> <data>
OK
If text mode ( AT+CMGF =1), command successful and SMS-
STATUS-REPORT:
+CMGR: <stat> , <fo> , <mr> ,[ <ra> ],[ <tora> ], <scts> , <dt> , <st>
OK
If text mode ( AT+CMGF =1), command successful and SMS-
COMMAND:
+CMGR: <stat> , <fo> , <ct> [, <pid> ,[ <mn> ],[ <da> ],[ <toda> ], <length
> ]<CR><LF> <data>
OK
If text mode ( AT+CMGF =1), command successful and CBM storage:
+CMGR: <stat> , <sn> , <mid> , <dcs> , <page> , <pages> <CR><LF> <d ata>
OK
If PDU mode ( AT+CMGF =0) and Command successful:
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CMGR: <stat> ,[ <alpha> ], <length> <CR><LF> <pdu>
OK
+CMS ERROR: <err>
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
<stat>
1.Text Mode :
"REC UNREAD" received unread message (i.e. new message)
"REC READ" received read message
"STO UNSENT" stored unsent message
"STO SENT" stored sent message
2. PDU Mode :
0 – received unread message (i.e. new message)
1 – received read message.
2 – stored unsent message.
3 – stored sent message
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tooa> .
<alpha>
String type alphanumeric representation of <da> or <oa> corresponding to the entry found in MT phonebook; implementation of this feature is manufacturer specific; used character set should be the one selected with command Select TE Character Set AT+CSCS .
<scts>
TP-Service-Centre-Time-Stamp in time-string format (refer <dt> ).
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda> ).
<fo>
Depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER,
SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format. SMS status report is supported under text mode if <fo> is set to 49.
<pid>
Protocol Identifier
GSM 03.40 TP-Protocol-Identifier in integer format
0…255
<dcs>
Depending on the command or result code: SMS Data Coding Scheme (default 0), or Cell
Broadcast Data Coding Scheme in integer format.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<sca>
RP SC address Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tosca> .
<tosca>
RP SC address Type-of-Address octet in integer format (default refer <toda> ).
<length>
Integer type value indicating in the text mode ( AT+CMGF =1) the length of the message body
<data> > (or <cdata> ) in characters; or in PDU mode ( AT+CMGF =0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length).
<data>
In the case of SMS: TP-User-Data in text mode responses; format:
1 – If <dcs> indicates that GSM 7 bit default alphabet is used and <fo> indicates that
TP-User-Data-Header-Indication is not set: a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current
TE character set. b. If TE character set is "HEX": ME/TA converts each 7-bit character of GSM 7 bit default alphabet into two IRA character long hexadecimal numbers. (e.g. character
Π
(GSM 7 bit default alphabet 23) is presented as 17 (IRA 49 and 55)).
2 – If <dcs> indicates that 8-bit or UCS2 data coding scheme is used, or <fo> indicates that
TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA character long hexadecimal numbers. (eg. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)).
3 – If <dcs> indicates that GSM 7 bit default alphabet is used: a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current
TE character set. b. If TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7 bit default alphabet into two IRA character long hexadecimal numbers.
4 – If <dcs> indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each 8-bit octet into two IRA character long hexadecimal numbers.
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda> .
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<vp>
Depending on SMS-SUBMIT <fo> setting: TP-Validity-Period either in integer format (default
167) or in time-string format (refer <dt> ).
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<ra>
Recipient Address
GSM 03.40 TP-Recipient-Address Address-Value field in string format;BCD numbers(or GSM default alphabet characters) are converted to characters of the currently selected TE character set(refer to command AT+CSCS );type of address given by <tora>
<tora>
Type of Recipient Address
GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda> )
<dt>
Discharge Time
GSM 03.40 TP-Discharge-Time in time-string format:”yy/MM/dd,hh:mm:ss+zz”,where characters indicate year (two last digits),month,day,hour,minutes,seconds and time zone.
<st>
Status
GSM 03.40 TP-Status in integer format
0…255
<ct>
Command Type
GSM 03.40 TP-Command-Type in integer format
0…255
<mn>
Message Number
GSM 03.40 TP-Message-Number in integer format
<sn>
Serial Number
GSM 03.41 CBM Serial Number in integer format
<mid>
Message Identifier
GSM 03.41 CBM Message Identifier in integer format
<page>
Page Parameter
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
<pages>
Page parameter
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
<pdu>
In the case of SMS: SC address followed by TPDU in hexadecimal format: ME/TA converts each octet of TP data unit into two IRA character long hexadecimal numbers. (eg. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)).
Examples
AT+CMGR=1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CMGR: "STO UNSENT","+10011",,145,17,0,0,167,"+8613800100500",145,4
Hello World
OK
7.13
AT+CMGS Send message
Description
This command is used to send message from a TE to the network (SMS-SUBMIT).
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CMGS=?
Responses
OK
Write Command
If text mode ( AT+CMGF =1):
AT+CMGS= <da> [, <toda> ] <
CR> Text is entered.
<CTRL-Z/ESC>
If PDU mode( AT+CMGF =
0):
AT+CMGS= <length> <CR>
PDU is entered
<CTRL-Z/ESC>
Responses
If text mode (
+CMGS: <mr>
If sending fails:
ERROR
OK
If PDU mode( AT+CMGF =0) and sending successfully:
+CMGS: <mr>
OK
AT+CMGF =1) and sending successfully:
If sending fails:
+CMS ERROR: <err>
Defined values
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda> .
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length> integer type value indicating in the text mode ( AT+CMGF =1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode ( AT+CMGF =0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length)
<mr>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
AT+CMGS="13012832788"<CR>(TEXT MODE)
> ABCD<ctrl-Z/ESC>
+CMGS: 46
OK
7.14
AT+CMSS Send message from storage
Description
This command is used to send message with location value <index> from preferred message storage <mem2> to the network (SMS-SUBMIT or SMS-COMMAND).
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CMSS=?
Write Command
AT+CMSS=
<index> [, <da> [, <toda> ]]
Responses
OK
Responses
+CMSS: <mr>
OK
ERROR
If sending fails:
+CMS ERROR: <err>
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda> .
<mr>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
AT+CMSS=3
+CMSS: 0
OK
AT+CMSS=3,"13012345678"
+CMSS: 55
OK
7.15
AT+CMGW Write message to memory
Description
This command is used to store message (either SMS-DELIVER or SMS-SUBMIT) to memory storage <mem2> .
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CMGW=?
Responses
OK
Write Command
If text mode( AT+CMGF =1):
AT+CMGW= <oa> / <da> [, <t ooa> / <toda> [, <stat> ]]<CR>
Text is entered.
<CTRL-Z/ESC>
If PDU mode( AT+CMGF =
0):
AT+CMGW= <length> [, <sta t> ]<CR> PDU is entered.
<CTRL-Z/ESC>
Responses
+CMGW: <index>
OK
ERROR
+CMS ERROR: <err>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tooa> .
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda> ).
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda> .
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length>
Integer type value indicating in the text mode ( AT+CMGF =1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode ( AT+CMGF =0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length).
<stat>
1. Text Mode:
"STO UNSENT" stored unsent message
"STO SENT" stored sent message
2. PDU Mode:
2 – stored unsent message
3 – stored sent message
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
AT+CMGW="13012832788" <CR> (TEXT MODE)
ABCD<ctrl-Z/ESC>
+CMGW:1
OK
7.16
AT+CMGD Delete message
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to delete message from preferred message storage <mem1> location
<index> . If <delflag> is present and not set to 0 then the ME shall ignore <index> and follow the rules for <delflag> shown below.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CMGD=?
Write Command
AT+CMGD=
<index> [, <delflag> ]
Responses
+CMGD: (list of supported <index> s)[,(list of supported
<delflag> s)]
OK
Responses
OK
ERROR
+CMS ERROR: <err>
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
<delflag>
0 – (or omitted) Delete the message specified in <index> .
1 – Delete all read messages from preferred message storage, leaving unread messages and stored mobile originated messages (whether sent or not) untouched.
2 – Delete all read messages from preferred message storage and sent mobile originated messages, leaving unread messages and unsent mobile originated messages untouched.
3 – Delete all read messages from preferred message storage, sent and unsent mobile originated messages leaving unread messages untouched.
4 – Delete all messages from preferred message storage including unread messages.
NOTE: If set <delflag> =1, 2, 3 or 4, <index> is omitted, such as AT+CMGD =,1.
Examples
AT+CMGD=1
OK
7.17
AT+CMGRO Read message only
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to return message with location value <index> from message storage
<mem1> to the TE, but the message’s status does not change.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMGRO=?
Write Command
AT+CMGRO= <index>
Responses
OK
Responses
If text mode( AT+CMGF =1),command successful and
SMS-DELIVER:
+CMGRO: <stat> , <oa> ,[ <alpha> ], <scts> [, <tooa> , <fo> , <pid> , <dcs
> , <sca> , <tosca> , <length> ]<CR><LF> <data>
OK
If text mode ( AT+CMGF =1),command successful and
SMS-SUBMIT:
+CMGRO: <stat> , <da> ,[ <alpha> ][, <toda> , <fo> , <pid> , <dcs> ,[ <vp
> ], <sca> , <tosca> , <length> ]<CR><LF> <data>
OK
If text mode( AT+CMGF =1),command successful and SMS-
STATUS-REPORT:
+CMGRO: <stat> , <fo> , <mr> ,[ <ra> ],[ <tora> ], <scts> , <dt> , <st>
OK
If text mode ( AT+CMGF =1),command successful and
SMS-COMMAND:
+CMGRO: <stat> , <fo> , <ct> [, <pid> ,[ <mn> ],[ <da> ],[ <toda> ], <lengt h> <CR><LF> <data> ]
OK
If text mode( AT+CMGF =1), command successful and CBM storage:
+CMGRO: <stat> , <sn> , <mid> , <dcs> , <page> , <pages> <CR><LF> < data>
OK
If PDU mode ( AT+CMGF =0) and command successful:
+CMGR: <stat> ,[ <alpha> ], <length> <CR><LF> <pdu>
OK
Otherwise:
+CMS ERROR: <err>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
Refer to command AT+CMGR.
Examples
AT+CMGRO=6
+CMGRO:"REC READ","+8613917787249",,"06/07/10,12:09:38+32",145,4,0,0,"+86138002105
00",145,4 abcd
OK
7.18
AT+CMGMT Change message status
Description
This command is used to change the message status. If the status is unread, it will be changed read.
Other statuses don’t change.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMGMT=?
Write Command
AT+CMGMT= <index>
Responses
OK
Responses
OK
ERROR
+CMS ERROR: <err>
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
Examples
AT+CMGMT=1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
7.19
AT+CMVP Set message valid period
Description
This command is used to set valid period for sending short message.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMVP=?
Read Command
AT+CMVP?
Write Command
AT+CMVP= <vp>
Responses
+CMVP: (list of supported <vp> s)
OK
Responses
+CMVP: <vp>
OK
Responses
OK
ERROR
+CMS ERROR: <err>
Defined values
<vp>
Validity period value:
0 to 143 ( <vp> +1) x 5 minutes (up to 12 hours)
144 to 167 12 hours + ( <vp> -143) x 30 minutes
168 to 196 ( <vp> -166) x 1 day
197 to 255 ( <vp> -192) x 1 week
Examples
AT+CMVP=167
OK
AT+CMVP?
+CMVP: 167
OK
7.20
AT+CMGRD Read and delete message
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to read message, and delete the message at the same time. It integrate
AT+CMGR and AT+CMGD , but it doesn’t change the message status.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMGRD=?
Write Command
AT+CMGRD= <index>
Responses
OK
Responses
If text mode( AT+CMGF =1),command successful and SMS-DE-
LIVER:
+CMGRD: <stat> , <oa> ,[ <alpha> ], <scts> [, <tooa> , <fo> , <pid> , <dcs
> , <sca> , <tosca> , <length> ]<CR><LF> <data>
OK
If text mode( AT+CMGF =1),command successful and SMS-SU-
BMIT:
+CMGRD: <stat> , <da> ,[ <alpha> ][, <toda> , <fo> , <pid> , <dcs> ,[ <vp
> ], <sca> , <tosca> , <length> ]<CR><LF> <data>
OK
If text mode( AT+CMGF =1),command successful and SMS-STA-
TUS- REPORT:
+CMGRD: <stat> , <fo> , <mr> ,[ <ra> ],[ <tora> ], <scts> , <dt> , <st>
OK
If text mode( AT+CMGF =1),command successful and SMS-CO-
MMAND:
+CMGRD: <stat> , <fo> , <ct> [, <pid> ,[ <mn> ],[ <da> ],[ <toda> ], <lengt h> <CR><LF> <data> ]
OK
If text mode( AT+CMGF =1),command successful and CBM storage:
+CMGRD: <stat> , <sn> , <mid> , <dcs> , <page> , <pages> <CR><LF> < data>
OK
If PDU mode( AT+CMGF =0) and command successful:
+CMGRD: <stat> ,[ <alpha> ], <length> <CR><LF> <pdu>
OK
ERROR
+CMS ERROR: <err>
Defined values
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Refer to command AT+CMGR.
Examples
AT+CMGRD=6
+CMGRD:"REC READ","+8613917787249",,"06/07/10,12:09:38+32",145,4,0,0, "+86138002105
00",145,4
How do you do
OK
7.21
AT+CMGSO Send message quickly
Description
This command is used to send message from a TE to the network (SMS-SUBMIT). But it’s different from AT+CMGS . This command only need one time input, and wait for “>” needless.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMGSO=?
Responses
OK
Write Command
If text mode ( AT+CMGF =1):
AT+CMGSO= <da> [, <toda>
], <text>
If PDU mode ( AT+CMGF
=0):
AT+CMGSO= <length> , <pd ucontent>
Responses
+CMGSO:
OK
ERROR
<mr>
+CMS ERROR: <err>
Defined values
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda> .
<length>
Integer type value indicating in the text mode ( AT+CMGF =1) the length of the message body
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<data> > (or <cdata>) in characters; or in PDU mode ( AT+CMGF =0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length).
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<text>
Content of message.
<pducontent>
Content of message.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
AT+CMGSO="10086","YECX"
+CMGSO: 128
OK
7.22
AT+CMGWO Write message to memory quickly
Description
This command stores message (either SMS-DELIVER or SMS-SUBMIT) to memory storage
<mem2> . But it’s different from AT+CMGW . This command only need one time input, and wait for
“>” needless.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMGWO=?
Responses
OK
Write Command
If text mode ( AT+CMGF =
1):
AT+CMGWO= <da> [, <toda
> ], <text>
If PDU mode ( AT+CMGF
=0):
AT+CMGWO= <length> , <p ducontent>
Responses
+CMGWO: <index>
OK
ERROR
+CMS ERROR: <err>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda> .
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<text>
Content of message.
<pducontent>
Content of message.
Examples
AT+CMGWO="13012832788","ABCD"
+CMGWO: 1
OK
7.23
AT+CMGSEX Send message
Description
This command is used to send message from a TE to the network (SMS-SUBMIT).
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CMGSEX=?
Responses
OK
Write Command Responses
If text mode ( AT+CMGF =1): If text mode ( AT+CMGF =1) and sending successfully:
AT+CMGSEX= <da> [, <toda +CMGSEX: <mr>
> ][, <mr> , <msg_seg> ,
OK
<msg_total >] <CR> Text is
AT+CMGF =0) and sending successfully: entered.
+CMGSEX: <mr>
<CTRL-Z/ESC>
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
If PDU mode( AT+CMGF =
0):
AT+CMGSEX= <length> <C
R>
PDU is entered
<CTRL-Z/ESC>
If sending fails:
ERROR
If sending fails:
+CMS ERROR: <err>
Defined values
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda> .
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (When first character of <da> is
+ (IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length>
Integer type value indicating in the text mode ( AT+CMGF =1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode ( AT+CMGF =0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length)
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<msg_seg>
The segment number for long sms
<msg_total>
The total number of the segments for long sms. Its range is from 2 to 255.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: For single SMS, it is 160 characters if the 7 bit GSM coding scheme is used; For multiple long sms, it is
153 characters if the 7 bit GSM coding scheme is used.
Examples
AT+CMGSEX="13012832788", 190, 1, 2<CR>(TEXT MODE)
> ABCD<ctrl-Z/ESC>
+CMGSEX: 190
OK
AT+CMGSEX="13012832788", 190, 2, 2<CR>(TEXT MODE)
> EFGH<ctrl-Z/ESC>
+CMGSEX: 190
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
7.24
AT+CMGENREF Generate a new message reference
Description
This command is used to generate a new message reference which can be used by AT+CMGSEX.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMGENREF=?
Execute Command
AT+CMGENREF
Responses
OK
Responses
+CMGENREF: <mr>
OK
Defined values
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
Examples
AT+CMGENREF=?
OK
AT+CMGENREF
+CMGENREF:190
OK
7.25
AT+CMSSEX Send multi messages from storage
Description
This command is used to send messages with location value <index1>,<index2>,<index3>… from preferred message storage <mem2> to the network (SMS-SUBMIT or SMS-COMMAND).The max count of index is 13 one time.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CMSSEX=?
Write Command
AT+CMSSEX=
<index> [, <index > [, … ]]
OK
Responses
+CMSSEX: <mr> [, <mr> [ ,… ]]
OK
ERROR
If sending fails:
[+CMSSEX: <mr> [, <mr> [ ,… ]]]
+CMS ERROR: <err>
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
AT+CMSSEX=0,1
+CMSSEX: 239,240
OK
AT+CMSSEX=0,1
+CMSSEX: 238
+CMS ERROR: Invalid memory index
7.26
AT+CMSSEXM Send message from storage to multi DA
Description
This command is used to send message with location value <index> from preferred message storage <mem2> to the network (SMS-SUBMIT or SMS-COMMAND).The DA is the PB index in the specified PB storage max to 10.
SIM PIN References
YES 3GPP TS 27.005
Syntax
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Test Command
AT+CMSSEXM=?
Write Command
AT+CMSSEXM=
<index> ,
<storage> , <pb_index1>
[, <pb_index2>[,<…>] ]
Responses
OK
Responses
+CMSSEXM: <pb_index1>,<mr>
+CMSSEXM: <pb_index2>,<mr>
…
OK
ERROR
If sending fails:
+CMSSEXM: <pb_index1> , <err>
+CMSSEXM: <pb_index2> , <err>
…
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
<storage>
Values reserved by the present document:
"DC" ME dialed calls list
Capacity: max. 10 entries
AT+CPBW command is not applicable to this storage.
"MC" ME missed (unanswered received) calls list
Capacity: max. 10 entries
AT+CPBW command is not applicable to this storage.
"RC" ME received calls list
Capacity: max. 10 entries
AT+CPBW command is not applicable to this storage.
"SM" SIM phonebook
Capacity: depending on SIM card
"ME" Mobile Equipment phonebook
Capacity: max. 100 entries
"FD" SIM fixdialling-phonebook
Capacity: depending on SIM card
"ON" MSISDN list
Capacity: depending on SIM card
"LD" Last number dialed phonebook
Capacity: depending on SIM card
AT+CPBW command is not applicable to this storage.
"EN" Emergency numbers
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Capacity: max. 50 entries
AT+CPBW command is not applicable to this storage.
"SN" Service Dialling Numbers
Capacity: depending on SIM card
AT+CPBW command is not applicable to this storage.
<pb_index>
Integer type value in the range of location numbers of phonebook memory.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
AT+CMSSEXM=0,”sm”,1,3
+CMSSEXM: 1,241
+CMSSEXM: 3,242
OK
AT+CMSSEXM=0,”sm”,1,2
+CMSSEXM: 1,invalid index
+CMSSEXM: 2,243
OK
7.27
AT+CSALPHA Set If Try To Match Alpha In PB
Description
This command is used to set if try to match alpha In PB when read message.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSALPHA=?
Read Command
AT+ CSALPHA?
Responses
+ CSALPHA: (list of supported <setting> s)
OK
Responses
+ CSALPHA: < setting >
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command Responses
AT+ CSALPHA = < setting > OK
Execution Command
AT+
CSALPHA
Responses
Set default value ( < setting > =1):
OK
Defined values
< setting >
0 – not to match alpha in PB
1 – try to match alpha in PB
Examples
AT+ CSALPHA ?
+ CSALPHA : 0
OK
AT+ CSALPHA =?
+ CSALPHA : (0-1)
OK
AT+ CSALPHA =1
OK
7.28
AT+CMGREX Read message
Description
This command is used to return message with location value <index> from message storage
<mem1> to the TE.This command supports long SMS operation.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command
AT+CMGREX=?
Write Command
AT+CMGREX= <index>
Responses
OK
Responses
If text mode ( AT+CMGF =1), command successful and SMS-
DELIVER:
+CMGREX:
<stat> , <oa> ,[ <alpha> ], <scts> [, <tooa> , <fo> , <pid> , <dcs> , <sca> ,
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<tosca> , <length> ], <mr> , <msg_seg> ,
<msg_total> <CR><LF> <data>
OK
If text mode ( AT+CMGF =1), command successful and SMS-
SUBMIT:
+CMGREX: <stat> , <da> ,[ <alpha> ][, <toda> , <fo> , <pid> , <dcs> ,[ <v p> ], <sca> , <tosca> , <length> ], <mr> , <msg_seg> ,
<msg_total> <CR><LF> <data>
OK
If text mode ( AT+CMGF =1), command successful and SMS-
STATUS-REPORT:
+CMGREX: <stat> , <fo> , <mr> ,[ <ra> ],[ <tora> ], <scts> , <dt> , <st>
OK
If text mode ( AT+CMGF =1), command successful and SMS-
COMMAND:
+CMGREX: <stat> , <fo> , <ct> [, <pid> ,[ <mn> ],[ <da> ],[ <toda> ], <len gth> ]<CR><LF> <data>
OK
If text mode ( AT+CMGF =1), command successful and CBM storage:
+CMGREX: <stat> , <sn> , <mid> , <dcs> , <page> , <pages> <CR><LF>
<data>
OK
If PDU mode ( AT+CMGF =0) and Command successful:
+CMGREX: <stat> ,[ <alpha> ], <length> <CR><LF> <pdu>
OK
+CMS ERROR: <err>
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
<stat>
1.Text Mode :
"REC UNREAD" received unread message (i.e. new message)
"REC READ" received read message
"STO UNSENT" stored unsent message
"STO SENT" stored sent message
2. PDU Mode :
0 – received unread message (i.e. new message)
1 – received read message.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
2 – stored unsent message.
3 – stored sent message
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tooa> .
<alpha>
String type alphanumeric representation of <da> or <oa> corresponding to the entry found in MT phonebook; implementation of this feature is manufacturer specific; used character set should be the one selected with command Select TE Character Set AT+CSCS .
<scts>
TP-Service-Centre-Time-Stamp in time-string format (refer <dt> ).
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda> ).
<fo>
Depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER,
SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format. SMS status report is supported under text mode if <fo> is set to 49.
<pid>
Protocol Identifier
GSM 03.40 TP-Protocol-Identifier in integer format
0…255
<dcs>
Depending on the command or result code: SMS Data Coding Scheme (default 0), or Cell
Broadcast Data Coding Scheme in integer format.
<sca>
RP SC address Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tosca> .
<tosca>
RP SC address Type-of-Address octet in integer format (default refer <toda> ).
<length>
Integer type value indicating in the text mode ( AT+CMGF =1) the length of the message body
<data> > (or <cdata> ) in characters; or in PDU mode ( AT+CMGF =0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length).
<data>
In the case of SMS: TP-User-Data in text mode responses; format:
1 – If <dcs> indicates that GSM 7 bit default alphabet is used and <fo> indicates that
TP-User-Data-Header-Indication is not set: a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current
TE character set. b. If TE character set is "HEX": ME/TA converts each 7-bit character of GSM 7 bit default alphabet into two IRA character long hexadecimal numbers. (e.g. character
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Π
(GSM 7 bit default alphabet 23) is presented as 17 (IRA 49 and 55)).
2 – If <dcs> indicates that 8-bit or UCS2 data coding scheme is used, or <fo> indicates that
TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA character long hexadecimal numbers. (eg. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)).
3 – If <dcs> indicates that GSM 7 bit default alphabet is used: a. If TE character set other than "HEX": ME/TA converts GSM alphabet into current
TE character set. b. If TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7 bit default alphabet into two IRA character long hexadecimal numbers.
4 – If <dcs> indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each 8-bit octet into two IRA character long hexadecimal numbers.
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda> .
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<vp>
Depending on SMS-SUBMIT <fo> setting: TP-Validity-Period either in integer format (default
167) or in time-string format (refer <dt> ).
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<ra>
Recipient Address
GSM 03.40 TP-Recipient-Address Address-Value field in string format;BCD numbers(or GSM default alphabet characters) are converted to characters of the currently selected TE character set(refer to command AT+CSCS );type of address given by <tora>
<tora>
Type of Recipient Address
GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda> )
<dt>
Discharge Time
GSM 03.40 TP-Discharge-Time in time-string format:”yy/MM/dd,hh:mm:ss+zz”,where characters indicate year (two last digits),month,day,hour,minutes,seconds and time zone.
<st>
Status
GSM 03.40 TP-Status in integer format
0…255
<ct>
Command Type
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
GSM 03.40 TP-Command-Type in integer format
0…255
<mn>
Message Number
GSM 03.40 TP-Message-Number in integer format
<sn>
Serial Number
GSM 03.41 CBM Serial Number in integer format
<mid>
Message Identifier
GSM 03.41 CBM Message Identifier in integer format
<page>
Page Parameter
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
<pages>
Page parameter
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
<pdu>
In the case of SMS: SC address followed by TPDU in hexadecimal format: ME/TA converts each octet of TP data unit into two IRA character long hexadecimal numbers. (eg. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)).
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<msg_seg>
The segment number for long sms
<msg_total>
The total number of the segments for long sms. Its range is from 2 to 255.
Examples
AT+CMGREX=1
+CMGREX: "STO UNSENT","+10011",,145,17,0,0,167,"+8613800100500",145,4,190,1,2
Hello World
OK
7.29
AT+CMGWEX Write message to memory
Description
This command is used to store message (either SMS-DELIVER or SMS-SUBMIT) to memory storage <mem2> . This command supports long SMS operation.
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
YES 3GPP TS 27.005
Syntax
Test Command
AT+CMGWEX=?
Responses
OK
Write Command
If text mode( AT+CMGF =1):
AT+CMGWEX= <oa> / <da> [
, <tooa> / <toda> [, <stat> [, <mr
> , <msg_seg> ,
Responses
+CMGWEX:
OK
ERROR
<index>
<msg_total >]]]<CR> Text is entered.
<CTRL-Z/ESC>
+CMS ERROR: <err>
If PDU mode( AT+CMGF =
0):
AT+CMGWEX= <length> [, < stat> ]<CR> PDU is entered.
<CTRL-Z/ESC>
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start with zero.
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <tooa> .
<tooa>
TP-Originating-Address, Type-of-Address octet in integer format. (default refer <toda> ).
<da>
Destination-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set, type of address given by <toda> .
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<length>
Integer type value indicating in the text mode ( AT+CMGF =1) the length of the message body
<data> > (or <cdata>) in characters; or in PDU mode ( AT+CMGF =0), the length of the actual TP data unit in octets. (i.e. the RP layer SMSC address octets are not counted in the length).
<stat>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
1. Text Mode:
"STO UNSENT" stored unsent message
"STO SENT" stored sent message
2. PDU Mode:
2 – stored unsent message
3 – stored sent message
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<msg_seg>
The segment number for long sms
<msg_total>
The total number of the segments for long sms. Its range is from 2 to 255.
NOTE: In text mode, the maximum length of an SMS depends on the used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
AT+CMGWEX="13012832788" ,,”STO SENT”,190, 1, 2<CR> (TEXT MODE)
ABCD<ctrl-Z/ESC>
+CMGWEX:1
OK
SIM5310_ATC_V2.00 10/15/2015
8 AT Commands for Phonebook
8.1
AT+CPBS Select phonebook memory storage
Description
This command selects the active phonebook storage,i.e.the phonebook storage that all subsequent phonebook commands will be operating on.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CPBS=?
Read Command
AT+CPBS?
Write Command
AT+CPBS= <storage>
Execution Command
AT+CPBS
Responses
+CPBS: (list of supported <storage> s)
OK
Responses
+CPBS: <storage> [, <used> , <total> ]
OK
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
Set default value “SM”:
OK
Defined values
<storage>
Values reserved by the present document:
"DC" ME dialed calls list
Capacity: max. 10 entries
AT+CPBW command is not applicable to this storage.
"MC" ME missed (unanswered received) calls list
Capacity: max. 10 entries
AT+CPBW command is not applicable to this storage.
SIM5310 AT Command Set
"RC" ME received calls list
Capacity: max. 10 entries
AT+CPBW command is not applicable to this storage.
"SM" SIM phonebook
Capacity: depending on SIM card
"ME" Mobile Equipment phonebook
Capacity: max. 100 entries
"FD" SIM fixdialling-phonebook
Capacity: depending on SIM card
"ON" MSISDN list
Capacity: depending on SIM card
"LD" Last number dialed phonebook
Capacity: depending on SIM card
AT+CPBW command is not applicable to this storage.
"EN" Emergency numbers
Capacity: max. 50 entries
AT+CPBW command is not applicable to this storage.
"SN" Service Dialling Numbers
Capacity: depending on SIM card
AT+CPBW command is not applicable to this storage.
<used>
Integer type value indicating the number of used locations in selected memory.
<total>
Integer type value indicating the total number of locations in selected memory.
Examples
AT+CPBS=?
+CPBS: ("SM","DC","FD","LD","MC","ME","RC","EN","ON","SN")
OK
AT+CPBS=”SM”
OK
AT+CPBS?
+CPBS: "SM",1,200
OK
8.2
AT+CPBR Read phonebook entries
Description
This command gets the record information from the selected memory storage in phonebook. If the storage is selected as “SM” then the command will return the record in SIM phonebook, the same to others.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CPBR=?
Write Command
AT+CPBR=
<index1> [, <index2> ]
Responses
+CPBR: ( <minIndex> <maxIndex> ), [ <nlength> ], [ <tlength> ]
OK
+CME ERROR: <err>
Responses
[+CPBR: <index1> , <number> , <type> , <text> [<CR><LF>
+CPBR: <index2> , <number> , <type> , <text> […]]]
OK
ERROR
+CME ERROR: <err>
Defined values
<index1>
Integer type value in the range of location numbers of phonebook memory.
<index2>
Integer type value in the range of location numbers of phonebook memory.
<index>
Integer type.the current position number of the Phonebook index.
<minIndex>
Integer type the minimum <index> number.
<maxIndex>
Integer type the maximum <index> number
<number>
String type, phone number of format <type> , the maximum length is <nlength> .
<type>
Type of phone number octet in integer format, default 145 when dialing string includes international access code character "+", otherwise 129.
<text>
String type field of maximum length <tlength> ; often this value is set as name.
<nlength>
Integer type value indicating the maximum length of field <number> .
<tlength>
Integer type value indicating the maximum length of field <text> .
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CPBS?
+CPBS: "SM",2,200
OK
AT+CPBR=1,10
+CPBR: 1,"1234567890",129,"James"
+CPBR: 2,"0987654321",129,"Kevin"
OK
8.3
AT+CPBF Find phonebook entries
Description
This command finds the record in phonebook (from the current phonebook memory storage
) which alphanumeric field has substring <findtext> .If <findtext> is null, it will lists all the entries.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CPBF=?
Write Command
AT+CPBF=[ <findtext> ]
Responses
+CPBF: [ <nlength> ],[ <tlength> ]
OK
+CME ERROR: <err>
Responses
[+CPBF: <index1> , <number> , <type> , <text> [<CR><LF>
+CPBF: <indexN> , <number> , <type> , <text> […]]]
OK
ERROR
+CME ERROR: <err>
Defined values
<findtext>
String type, this value is used to find the record. Character set should be the one selected with command AT+CSCS.
<index>
Integer type values in the range of location numbers of phonebook memory.
<number>
String type, phone number of format <type> , the maximum length is <nlength> .
<type>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Type of phone number octet in integer format, default 145 when dialing string includes international access code character "+", otherwise 129.
<text>
String type field of maximum length <tlength> ; Often this value is set as name.
<nlength>
Integer type value indicating the maximum length of field <number> .
<tlength>
Integer type value indicating the maximum length of field <text> .
Examples
AT+CPBF=" James "
+CPBF: 1,"1234567890",129," James "
OK
8.4
AT+CPBW Write phonebook entry
Description
This command writes phonebook entry in location number <index> in the current phonebook
memory storage selected with AT+CPBS
.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CPBW=?
Write Command
AT+CPBW=[ <index> ][, <nu mber> [, <type> [, <text> ]]]
Responses
+CPBW:(list of supported <index> s),[ <nlength> ],
(list of supported <type> s),[ <tlength> ]
OK
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<index>
Integer type values in the range of location numbers of phonebook memory.If <index> is not given, the first free entry will be used. If <index> is given as the only parameter, the phonebook entry specified by <index> is deleted.If record number <index> already exists, it will be overwritten.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<number>
String type, phone number of format <type> , the maximum length is <nlength> .It must be an non-empty string.
<type>
Type of address octet in integer format, The range of value is from 128 to 255. If <number> contains a leading “+” <type> = 145 (international) is used.Supported value are:
128 – Restricted number type includes unknown type and format
145 – when dialling string includes international access code character “+”
161 – national number.The network support for this type is optional
177 – network specific number,ISDN format
129 – otherwise
NOTE: Other value refer TS 24.008 [8] subclause 10.5.4.7.
<text>
String type field of maximum length <tlength> ; character set as specified by command Select TE
Character Set
.
<nlength>
Integer type value indicating the maximum length of field <number> .
<tlength>
Integer type value indicating the maximum length of field <text> .
NOTE: If the parameters of <type> and <text> are omitted and the first character of <number> is
‘+’ , it will specify <type> as 145(129 if the first character isn’t ‘+’) and <text> as NULL.
Examples
AT+CPBW=3,"88888888",129,"John"
OK
AT+CPBW=,”6666666”,129,”mary”
OK
AT+CPBW=1
OK
8.5
AT+CNUM Subscriber number
Description
Execution command returns the MSISDNs related to the subscriber (this information can be stored in the SIM or in the ME). If subscriber has different MSISDN for different services, each MSISDN is returned in a separate line.
SIM PIN References
YES 3GPP TS 27.007
Syntax
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Test Command
AT+CNUM=?
Execution Command
AT+CNUM
Responses
OK
Responses
[+CNUM: <alpha> , <number> , <type> [<CR><LF>
+CNUM: <alpha> , <number> , <type> [...]]]
OK
+CME ERROR: <err>
Defined values
<alpha>
Optional alphanumeric string associated with <number> , used character set should be the one selected with command Select TE Character Set AT+CSCS .
<number>
String type phone number of format specified by <type> .
<type>
Type of address octet in integer format.see also AT+CPBR <type>
Examples
AT+CNUM
+CNUM: ,"13697252277",129
OK
8.6
AT+CEMNLIST Set the list of emergency number
Description
This command allows user to define emergency number list which stored in ME.
NOTE: These emergency numbers in this list only be available without SIMCard or with P
IN locked.Once SIM card is here without pin locked, this list will not be accessable, but c ustomer could access another emergency number list from phone book on “EN” entry, pleas e refer to command AT+CPBS. This “EN” list is usually released by SIM card provider.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CEMNLIST=?
Read Command
Responses
+CEMNLIST: (list of supported <mode> s), <nlength>,<total>
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CEMNLIST?
Write Command
AT+CEMNLIST= <mode> [,
<emergency numbers> ]
+CEMNLIST: <mode> , <emergency numbers>
OK
Responses
OK
Defined values
<mode>
0 disable
1 enable
2 edit emergency numbers
<nlength>
Integer type value indicating the maximum length of single emergency number.
<total>
Integer type value indicating the total number of emergency numbers.
<emergency numbers>
Emergency numbers list, string type.
<emergency number> includes all of emergency numbers,every emergency number is seperated by comma,for example “911,112”.
Examples
AT+CEMNLIST=?
+CEMNLIST: (0-2),10,30
OK
AT+CEMNLIST?
+CEMNLIST: 1,”911,112”
OK
AT+CEMNLIST=1
OK
AT+CEMNLIST=2,”911,112”
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
9 AT Commands for GPRS
9.1
AT+CGREG GPRS network registration status
Description
This command controls the presentation of an unsolicited result code “+CGREG: <stat> ” when
<n> =1 and there is a change in the MT's GPRS network registration status.
The read command returns the status of result code presentation and an integer <stat> which shows
Whether the network has currently indicated the registration of the MT.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CGREG=?
Read Command
AT+CGREG?
Write Command
AT+CGREG= <n>
Execution Command
AT+CGREG
Responses
+CGREG: (list of supported <n> s)
OK
Responses
+CGREG: <n> , <stat> [, <lac> , <ci> ]
OK
Responses
OK
Responses
Set default value:
OK
Defined values
<n>
0 – disable network registration unsolicited result code
1 – enable network registration unsolicited result code +CGREG: <stat>
2 – there is a change in the ME network registration status or a change of the network cell:
+CGREG: <stat> [, <lac> , <ci> ]
<stat>
0 – not registered, ME is not currently searching an operator to register to
1 – registered, home network
2 – not registered, but ME is currently trying to attach or searching an operator to register to
3 – registration denied
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
4 – unknown
5 – registered, roaming
<lac>
Two bytes location area code in hexadecimal format (e.g.”00C3” equals 193 in decimal).
<ci>
Cell ID in hexadecimal format.
GSM : Maximum is two byte
WCDMA : Maximum is four byte
Examples
AT+CGREG=?
+CGREG: (0-1)
OK
AT+CGREG?
+CGREG: 0,0
OK
9.2
AT+CGATT Packet domain attach or detach
Description
The write command is used to attach the MT to, or detach the MT from, the Packet Domain service.
The read command returns the current Packet Domain service state.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGATT=?
Read Command
AT+CGATT?
Write Command
AT+CGATT= <state>
Responses
+CGATT: (list of supported <state> s)
OK
Responses
+CGATT: <state>
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<state>
Indicates the state of Packet Domain attachment:
0 – detached
1 – attached
Examples
AT+CGATT?
+CGATT: 0
OK
AT+CGATT=1
OK
9.3
AT+CGACT PDP context activate or deactivate
Description
The write command is used to activate or deactivate the specified PDP context (s).
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGACT=?
Read Command
AT+CGACT?
Write Command
AT+CGACT= <state>
[, <cid> ]
Responses
+CGACT: (list of supported <state> s)
OK
Responses
+CGACT: [ <cid> , <state> [<CR><LF>
+CGACT: <cid> , <state>
[...]]]
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<state>
Indicates the state of PDP context activation:
0 – deactivated
1 – activated
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command).
1…16
Examples
AT+CGACT?
+CGACT: 1,0
OK
AT+CGACT=?
+CGACT: (0,1)
OK
AT+CGACT=0,1
OK
9.4
AT+CGDCONT Define PDP context
Description
The set command specifies PDP context parameter values for a PDP context identified by the
(local) context identification parameter <cid> . The number of PDP contexts that may be in a defined state at the same time is given by the range returned by the test command. A special form of the write command ( AT+CGDCONT = <cid>) causes the values for context <cid> to become undefined.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGDCONT=?
Read Command
AT+CGDCONT?
Responses
+CGDCONT: (range of supported <cid> s), <PDP_type> ,,,(list of supported <d_comp> s),(list of supported <h_comp> s)
OK
ERROR
Responses
+CGDCONT: [ <cid> , <PDP_type> , <APN> , <PDP_addr> ,
<d_comp> , <h_comp> [<CR><LF>
+CGDCONT: <cid> , <PDP_type> , <APN> , <PDP_addr> ,
<d_comp> , <h_comp> [...]]]
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
AT+CGDCONT=
<cid> [, <PDP_type>
[, <APN> [, <PDP_addr>
[, <d_comp> [, <h_comp> ]]]]]
Execution Command
AT+CGDCONT
Responses
OK
ERROR
Responses
OK
ERROR
Defined values
<cid>
(PDP Context Identifier) a numeric parameter which specifies a particular PDP context definition.
The parameter is local to the TE-MT interface and is used in other PDP context-related commands.
The range of permitted values (minimum value = 1) is returned by the test form of the command.
1…16
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
<APN>
(Access Point Name) a string parameter which is a logical name that is used to select the GGSN or the external packet data network.
<PDP_addr>
A string parameter that identifies the MT in the address space applicable to the PDP.
Read command will continue to return the null string even if an address has been allocated during the PDP startup procedure. The allocated address may be read using command AT+CGPADDR .
<d_comp>
A numeric parameter that controls PDP data compression, this value may depend on platform:
0 – off (default if value is omitted)
1 – on
2 – V.42bis
<h_comp>
A numeric parameter that controls PDP header compression, this value may depend on platform:
0 – off (default if value is omitted)
1 – on
2 – RFC1144
3 – RFC2507
4 – RFC3095
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CGDCONT?
+CGDCONT: 1,"IP","","0.0.0.0",0,0
OK
AT+CGDCONT=?
+CGDCONT: (1-16),"IP",,,(0-2),(0-4)
+CGDCONT: (1-16),"PPP",,,(0-2),(0-4)
+CGDCONT: (1-16),"IPV6",,,(0-2),(0-4)
OK
9.5
AT+CGDSCONT Define Secondary PDP Context
Description
The set command specifies PDP context parameter values for a Secondary PDP context identified by the (local) context identification parameter, <cid>. The number of PDP contexts that may be in a defined state at the same time is given by the range returned by the test command. A special form of the set command, AT+CGDSCONT=<cid> causes the values for context number <cid> to become undefined.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGDSCONT=?
Read Command
AT+CGDSCONT?
Write Command
AT
+CGDSCONT= <cid> [, <p_ci d> [, <d_comp> [, <h_comp> ]]
]
Responses
+CGDSCONT: (range of supported <cid> s),(list of <p_cid> s for active primary contexts),(list of supported <d_comp> s),(list of supported <h_comp> s)
OK
Responses
+CGDSCONT: <cid> , <p_cid> , <d_comp> , <h_comp>
[<CR><LF>+CGDSCONT: <cid> , <p_cid> , <d_comp> , <h_comp>
[...]]
OK
Responses
OK
ERROR
Defined values
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<cid> a numeric parameter which specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands. The range of permitted values (minimum value = 1) is returned by the test form of the command.
NOTE: The <cid>s for network-initiated PDP contexts will have values outside the ranges indicated for the <cid> in the test form of the commands +CGDCONT and +CGDSCONT.
<p_cid> a numeric parameter which specifies a particular PDP context definition which has been specified by use of the +CGDCONT command. The parameter is local to the TE-MT interface. The list of permitted values is returned by the test form of the command.
<d_comp> a numeric parameter that controls PDP data compression (applicable for SNDCPonly) (refer
3GPP TS 44.065 [61])
0 off
1 on (manufacturer preferred compression)
2 V.42bis
Other values are reserved.
<h_comp> a numeric parameter that controls PDP header compression (refer 3GPP TS 44.065 [61] and
3GPP TS 25.323 [62])
0 off
1 on (manufacturer preferred compression)
2 RFC1144 (applicable for SNDCP only)
3 RFC2507
4 RFC3095 (applicable for PDCP only)
Other values are reserved.
Examples
AT+CGDSCONT?
+CGDSCONT: 2,1,0,0
OK
AT+CGDSCONT=2,1
OK
AT+CGDSCONT=?
+CGDSCONT: (1-16),(1),"IP",,,(0-2),(0-4)
+CGDSCONT: (1-16),(1),"PPP",,,(0-2),(0-4)
+CGDSCONT: (1-16),(1),"IPV6",,,(0-2),(0-4)
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
9.6
AT+CGTFT Traffic Flow Template
Description
This command allows the TE to specify a Packet Filter - PF for a Traffic Flow Template - TFT that is used in the GGSN in UMTS/GPRS and Packet GW in EPS for routing of packets onto different
QoS flows towards the TE. The concept is further described in the 3GPP TS 23.060 [47]. A TFT consists of from one and up to 16 Packet Filters, each identified by a unique <packet filter identifier>. A Packet Filter also has an <evaluation precedence index> that is unique within all TFTs associated with all PDP contexts that are associated with the same PDP address.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGTFT=?
Read Command
AT+CGTFT?
Responses
+CGTFT: <PDP_type> ,(list of supported <packet filter identifier> s),(list of supported <evaluation precedence index> s),(list of supported <source address and subnet mask> s),(list of supported <protocol number (ipv4) / next header
(ipv6)> s),(list of supported <destination port range> s),(list of supported <source port range> s),(list of supported <ipsec security parameter index (spi)> s),(list of supported <type of service (tos)
(ipv4) and mask / traffic class (ipv6) and mask> s),(list of supported
<flow label (ipv6)> s),(list of supported <direction> s)
[<CR><LF>+CGTFT: <PDP_type> ,(list of supported <packet filter identifier> s),(list of supported <evaluation precedence index> s),(list of supported <source address and subnet mask> s),(list of supported <protocol number (ipv4) / next header
(ipv6)> s),(list of supported <destination port range> s),(list of supported <source port range> s),(list of supported <ipsec security parameter index (spi)> s),(list of supported <type of service (tos)
(ipv4) and mask / traffic class (ipv6) and mask> s),(list of supported
<flow label (ipv6)> s),(list of supported <direction> s)
[...]]
OK
Responses
+CGTFT: <cid> , <packet filter identifier> , <evaluation precedence index> , <source address and subnet mask> , <protocol number (ipv4)
/ next header (ipv6)> , <destination port range> , <source port range> , <ipsec security parameter index (spi)> , <type of service (tos)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
+CGTFT= <cid> [,[ <packet
Responses
OK filter identifier> , <evaluation precedence index> [, <source
ERROR address and subnet mask> [, <protocol number
(ipv4) / next header
(ipv6)> [, <destination port range> [, <source port range> [, <ipsec security parameter index
(spi)> [, <type of service (tos)
(ipv4) and mask / traffic class (ipv6) and mask> [, <flow label
(ipv6)> [, <direction> ]]]]]]]]]]
(ipv4) and mask / traffic class (ipv6) and mask> , <flow label
(ipv6)>,<direction>
[<CR><LF>+CGTFT: <cid> , <packet filter identifier> , <evaluation precedence index> , <source address and subnet mask> , <protocol number (ipv4) / next header (ipv6)> , <destination port range> , <source port range> , <ipsec security parameter index
(spi)> , <type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask> , <flow label (ipv6)>,<direction>
[...]]
OK
Defined values
<cid> a numeric parameter which specifies a particular PDP context definition (see the AT+CGDCONT and AT+CGDSCONT commands).
<packet filter identifier> a numeric parameter, value range from 1 to 16.
<evaluation precedence index> a numeric parameter. The value range is from 0 to 255.
<source address and subnet mask> string type The string is given as dot-separated numeric (0-255) parameters on the form:
"a1.a2.a3.a4.m1.m2.m3.m4" for IPv4 or
"a1.a2.a3.a4.a5.a6.a7.a8.a9.a10.a11.a12.a13.a14.a15.a16.m1.m2.m3.m4.m5.m6.m7.m8.m9.m10.m1
1.m12.m13.m14.m15.m16", for IPv6.
<protocol number (ipv4) / next header (ipv6)>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set a numeric parameter, value range from 0 to 255.
<destination port range> string type. The string is given as dot-separated numeric (0-65535) parameters on the form "f.t".
<source port range> string type. The string is given as dot-separated numeric (0-65535) parameters on the form "f.t".
<ipsec security parameter index (spi)> numeric value in hexadecimal format. The value range is from 00000000 to FFFFFFFF.
<type of service (tos) (ipv4) and mask / traffic class (ipv6) and mask> string type. The string is given as dot-separated numeric (0-255) parameters on the form "t.m".
<flow label (ipv6)> numeric value in hexadecimal format. The value range is from 00000 to FFFFF. Valid for IPv6 only.
<direction> a numeric parameter which specifies the transmission direction in which the packet filter shall be applied.
0 Pre-Release 7 TFT filter (see 3GPP TS 24.008 [8], table 10.5.162)
1 Uplink
2 Downlink
3 Birectional (Up & Downlink)
Examples
AT+CGTFT?
+CGTFT: 2,1,0,"74.125.71.99.255.255.255.255",0,0.0,0.0,0,0.0,0
OK
AT+CGTFT=2,1,0,"74.125.71.99.255.255.255.255"
OK
AT+CGTFT=?
+CGTFT: "IP",(1-2),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFF
FFF),(0-255.0-255),(0-FFFFF)
+CGTFT: "PPP",(1-2),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFF
FFFF),(0-255.0-255),(0-FFFFF)
+CGTFT: "IPV6",(1-2),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFF
FFFFF),(0-255.0-255),(0-FFFFF)
OK
9.7
AT+CGQREQ Quality of service profile (requested)
Description
This command allows the TE to specify a Quality of Service Profile that is used when the MT sends an Activate PDP Context Request message to the network.. A special form of the set command
( AT+CGQREQ = <cid>) causes the requested profile for context number <cid> to become
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set undefined.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGQREQ=?
Read Command
AT+CGQREQ?
Write Command
AT+CGQREQ= <cid>
[, <precedence>
[, <delay> [, <reliability>
[, <peak> [, <mean> ]]]]]
Execution Command
AT+CGQREQ
Responses
+CGQREQ: <PDP_type> , (list of supported <precedence> s), (list of supported <delay> s), (list of supported <reliability> s) , (list of supported <peak> s), (list of supported <mean> s) [<CR><LF>
+CGQREQ: <PDP_type> , (list of supported <precedence> s), (list of supported <delay> s), (list of supported <reliability> s) , (list of supported <peak> s), (list of supported <mean> s)
[…]]
OK
ERROR
Responses
+CGQREQ: [ <cid> , <precedence > , <delay> , <reliability> ,
<peak> , <mean> [<CR><LF>
+CGQREQ: <cid> , <precedence > , <delay> , <reliability.> , <peak> ,
<mean> […]]]
OK
ERROR
Responses
OK
ERROR
Responses
OK
ERROR
Defined values
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command). The range is from 1 to 16.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
<precedence>
A numeric parameter which specifies the precedence class:
0 – network subscribed value
1 – high priority
2 – normal priority
3 – low priority
<delay>
A numeric parameter which specifies the delay class:
0 – network subscribed value
1 – delay class 1
2 – delay class 2
3 – delay class 3
4 – delay class 4
<reliability>
A numeric parameter which specifies the reliability class:
0 – network subscribed value
1 – Non real-time traffic,error-sensitive application that cannot cope with data loss
2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss
3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/-
SM,and SMS
4 – Real-time traffic,error-sensitive application that can cope with data loss
5 – Real-time traffic error non-sensitive application that can cope with data loss
<peak>
A numeric parameter which specifies the peak throughput class:
0 – network subscribed value
1 – Up to 1000 (8 kbit/s)
2 – Up to 2000 (16 kbit/s)
3 – Up to 4000 (32 kbit/s)
4 – Up to 8000 (64 kbit/s)
5 – Up to 16000 (128 kbit/s)
6 – Up to 32000 (256 kbit/s)
7 – Up to 64000 (512 kbit/s)
8 – Up to 128000 (1024 kbit/s)
9 – Up to 256000 (2048 kbit/s)
<mean>
A numeric parameter which specifies the mean throughput class:
0 – network subscribed value
1 – 100 (~0.22 bit/s)
2 – 200 (~0.44 bit/s)
3 – 500 (~1.11 bit/s)
4 – 1000 (~2.2 bit/s)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
5 – 2000 (~4.4 bit/s)
6 – 5000 (~11.1 bit/s)
7 – 10000 (~22 bit/s)
8 – 20000 (~44 bit/s)
9 – 50000 (~111 bit/s)
10 – 100000 (~0.22 kbit/s)
11 – 200000 (~0.44 kbit/s)
12 – 500000 (~1.11 kbit/s)
13 – 1000000 (~2.2 kbit/s)
14 – 2000000 (~4.4 kbit/s)
15 – 5000000 (~11.1 kbit/s)
16 – 10000000 (~22 kbit/s)
17 – 20000000 (~44 kbit/s)
18 – 50000000 (~111 kbit/s)
31 – optimization
Examples
AT+CGQREQ?
+CGQREQ:
OK
AT+CGQREQ=?
+CGQREQ: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQREQ: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQREQ: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
OK
9.8
AT+CGEQREQ 3G quality of service profile (requested)
Description
The test command returns values supported as a compound value.
The read command returns the current settings for each defined context for which a QOS was explicitly specified.
The write command allows the TE to specify a Quality of Service Profile for the context identified by the context identification parameter <cid> which is used when the MT sends an Activate PDP
Context Request message to the network.
A special form of the write command, AT+CGEQREQ = <cid> causes the requested profile for context number <cid> to become undefined.
SIM PIN References
YES 3GPP TS 27.007
Syntax
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Test Command
AT+CGEQREQ=?
Responses
+CGEQREQ: <PDP_type> ,(list of supported <Traffic class> s),(list of supported <Maximum bitrate UL> s),(list of supported <Maxim um bitrate DL> s),(list of supported <Guaranteed bitrate UL> s,(list of supported <Guaranteed bitrate DL> s),(list of supported <Deliv ery order> s),(list of supported <Maximum SDU size> s),(list of supported <SDU error ratio> s),(list of supported <Residual bit error
Ratio> s),(list of supported <Delivery of erroneous SDUs> s),(list of
Supported <Transfer delay> s),(list of supported <Traffic handling priority> s)
OK
Read Command
AT+CGEQREQ?
Responses
+CGEQREQ: [ <cid> , <Traffic class> , <Maximum bitrate UL> , <Ma ximum bitrate DL> , <Guaranteed bitrate UL> , <Guaranteed bitrate
DL> , <Delivery order> , <Maximum SDU size> , <SDU error ratio> ,
<Residual bit error ratio> , <Delivery of erroneous SDUs> , <Transfer
Delay> , <Traffic handling priority> ][<CR><LF>
+CGEQREQ: <cid> , <Traffic class> , <Maximum bitrate UL> , <Ma ximum bitrate DL> , <Guaranteed bitrate UL> , <Guaranteed bitrate
DL> , <Delivery order> , <Maximum SDU size> , <SDU error ratio> ,
<Residual bit error ratio> , <Delivery of erroneous SDUs> , <Transfer
Delay> , <Traffic handling priority> […]]
OK
Write Command
AT+CGEQREQ= <cid> [, <Tr affic class> [, <Maximum bit rate UL >[, <Maximum bitrat e DL >[, <Guaranteed bitrate
UL >[, <Guaranteed bitrate
DL >[, <Delivery order> [, <M aximum SDU size> [, <SDU error ratio> [, <Residual bit error ratio> [, <Delivery of e rroneous SDUs> [, <Transfer delay> [, <Traffic handling p riority> ]]]]]]]]]]]]
Responses
OK
ERROR
+CME ERROR: <err>
Execution Command
AT+CGEQREQ
Responses
OK
Defined values
<cid>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Parameter specifies a particular PDP context definition.The parameter is also used in other PDP context-related commands. The range is from 1 to 16.
<Traffic class>
0 – conversational
1 – streaming
2 – interactive
3 – background
4 – subscribed value
<Maximum bitrate UL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a
SAP. As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQREQ =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Maximum bitrate DL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQREQ =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Guaranteed bitrate UL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.
AT+CGEQREQ =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Guaranteed bitrate DL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.
AT+CGEQREQ =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Delivery order>
This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.
0 – no
1 – yes
2 – subscribed value
<Maximum SDU size>
This parameter indicates the maximum allowed SDU size in octets.
The range is from 0 to 1520. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<SDU error ratio>
This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10
-3 would be specified as “5E3”(e.g.AT+CGEQREQ=..,”5E3”,…).
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
“0E0” – subscribed value
“1E2”
“7E3”
“1E3”
“1E4”
“1E5”
“1E6”
“1E1”
<Residual bit error ratio>
This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered
SDUs.As an example a target residual bit error ratio of 5*10
-3
would be specified as “5E3”(e.g.
AT+CGEQREQ=…,”5E3”,..).
“0E0” – subscribed value
“5E2”
“1E2”
“5E3”
“4E3”
“1E3”
“1E4”
“1E5”
“1E6”
“6E8”
<Delivery of erroneous SDUs>
This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
0 – no
1 – yes
2 – no detect
3 – subscribed value
<Transfer delay>
This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP,in milliseconds.
The range is from 0 to 4000. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Traffic handling priority>
This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS
Bearer compared to the SDUs of the other bearers.
The range is from 0 to 3. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
IPV6 Internet Protocol Version 6
Examples
AT+CGEQREQ?
+CGEQREQ:
OK
AT+CGEQREQ=?
+CGEQREQ: "IP",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0","1E
1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E
4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
+CGEQREQ: "PPP",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0","1
E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1
E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
+CGEQREQ: "IPV6",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0","
1E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","
1E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
OK
9.9
AT+CGQMIN Quality of service profile (minimum acceptable)
Description
This command allows the TE to specify a minimum acceptable profile which is checked by the MT against the negotiated profile returned in the Activate PDP Context Accept message.A special form of the set command, AT+CGQMIN = <cid> causes the minimum acceptable profile for context number <cid> to become undefined.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGQMIN=?
Read Command
Responses
+CGQMIN: <PDP_type> , (list of supported <precedence> s), (list of supported <delay> s), (list of supported <reliability> s) , (list of supported <peak> s), (list of supported <mean> s) [<CR><LF>
+CGQMIN: <PDP_type> , (list of supported <precedence> s), (list of supported <delay> s), (list of supported <reliability> s) , (list of supported <peak> s), (list of supported <mean> s)[…]]
OK
ERROR
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CGQMIN?
Write Command
AT+CGQMIN=
<cid> [, <precedence>
[, <delay> [, <reliability>
[, <peak> [, <mean> ]]]]]
Execution Command
AT+CGQMIN
+CGQMIN: [ <cid> , <precedence > , <delay> , <reliability> ,
<peak> , <mean> [<CR><LF>
+CGQMIN: <cid> , <precedence > , <delay> , <reliability.> , <peak> ,
<mean>
[…]]]
OK
ERROR
Responses
OK
ERROR
Responses
OK
Defined values
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command). The range is from 1 to 16.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
<precedence>
A numeric parameter which specifies the precedence class:
0 – network subscribed value
1 – high priority
2 – normal priority
3 – low priority
<delay>
A numeric parameter which specifies the delay class:
0 – network subscribed value
1 – delay class 1
2 – delay class 2
3 – delay class 3
4 – delay class 4
<reliability>
A numeric parameter which specifies the reliability class:
0 – network subscribed value
1 – Non real-time traffic,error-sensitive application that cannot cope with data loss
2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/-
SM,and SMS
4 – Real-time traffic,error-sensitive application that can cope with data loss
5 – Real-time traffic error non-sensitive application that can cope with data loss
<peak>
A numeric parameter which specifies the peak throughput class:
0 – network subscribed value
1 – Up to 1000 (8 kbit/s)
2 – Up to 2000 (16 kbit/s)
3 – Up to 4000 (32 kbit/s)
4 – Up to 8000 (64 kbit/s)
5 – Up to 16000 (128 kbit/s)
6 – Up to 32000 (256 kbit/s)
7 – Up to 64000 (512 kbit/s)
8 – Up to 128000 (1024 kbit/s)
9 – Up to 256000 (2048 kbit/s)
<mean>
A numeric parameter which specifies the mean throughput class:
0 – network subscribed value
1 – 100 (~0.22 bit/s)
2 – 200 (~0.44 bit/s)
3 – 500 (~1.11 bit/s)
4 – 1000 (~2.2 bit/s)
5 – 2000 (~4.4 bit/s)
6 – 5000 (~11.1 bit/s)
7 – 10000 (~22 bit/s)
8 – 20000 (~44 bit/s)
9 – 50000 (~111 bit/s)
10 – 100000 (~0.22 kbit/s)
11 – 200000 (~0.44 kbit/s)
12 – 500000 (~1.11 kbit/s)
13 – 1000000 (~2.2 kbit/s)
14 – 2000000 (~4.4 kbit/s)
15 – 5000000 (~11.1 kbit/s)
16 – 10000000 (~22 kbit/s)
17 – 20000000 (~44 kbit/s)
18 – 50000000 (~111 kbit/s)
31 – optimization
Examples
AT+CGQMIN?
+CGQMIN:
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CGQMIN=?
+CGQMIN: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQMIN: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGQMIN: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
OK
9.10
AT+CGEQMIN 3G quality of service profile (minimum acceptable)
Description
The test command returns values supported as a compound value.
The read command returns the current settings for each defined context for which a QOS was explicitly specified.
The write command allow the TE to specify a Quallity of Service Profile for the context identified by the context identification parameter <cid> which is checked by the MT against the negotiated profile returned in the Activate/Modify PDP Context Accept message.
A special form of the write command, AT+CGEQMIN = <cid> causes the requested for context number <cid> to become undefined.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGEQMIN=?
Read Command
AT+CGEQMIN?
Responses
+CGEQMIN: <PDP_type> ,(list of supported <Traffic class> s),(list of supported <Maximum bitrate UL> s),(list of supported <Maxim um bitrate DL> s),(list of supported <Guaranteed bitrate UL> s,(list of supported <Guaranteed bitrate DL> s),(list of supported <Deliv ery order> s),(list of supported <Maximum SDU size> s),(list of supported <SDU error ratio> s),(list of supported <Residual bit error
Ratio> s),(list of supported <Delivery of erroneous SDUs> s),(list of
Supported <Transfer delay> s),(list of supported <Traffic handling priority> s)
OK
Responses
+CGEQMIN: [ <cid> , <Traffic class> , <Maximum bitrate UL> , <Ma ximum bitrate DL> , <Guaranteed bitrate UL> , <Guaranteed bitrate
DL> , <Delivery order> , <Maximum SDU size> , <SDU error ratio> ,
<Residual bit error ratio> , <Delivery of erroneous SDUs> , <Transfer
Delay> , <Traffic handling priority> ][<CR><LF>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CGEQMIN: <cid> , <Traffic class> , <Maximum bitrate UL> , <Ma ximum bitrate DL> , <Guaranteed bitrate UL> , <Guaranteed bitrate
DL> , <Delivery order> , <Maximum SDU size> , <SDU error ratio> ,
<Residual bit error ratio> , <Delivery of erroneous SDUs> , <Transfer
Delay> , <Traffic handling priority> […]]
OK
Write Command
AT+CGEQMIN= <cid> [, <Tr affic class> [, <Maximum bit rate UL >[, <Maximum bitrat e DL >[, <Guaranteed bitrate
UL >[, <Guaranteed bitrate
DL >[, <Delivery order> [, <M aximum SDU size> [, <SDU error ratio> [, <Residual bit error ratio> [, <Delivery of e rroneous SDUs> [, <Transfer delay> [, <Traffic handling p riority> ]]]]]]]]]]]]
Responses
OK
ERROR
+CME ERROR: <err>
Execution Command
AT+CGEQMIN
Responses
OK
Defined values
<cid>
Parameter specifies a particular PDP context definition.The parameter is also used in other PDP context-related commands. The range is from 1 to 16.
<Traffic class>
0 – conversational
1 – streaming
2 – interactive
3 – background
4 – subscribed value
<Maximum bitrate UL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQMIN =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Maximum bitrate DL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g. AT+CGEQMIN =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set will be requested.
<Guaranteed bitrate UL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.
AT+CGEQMIN =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Guaranteed bitrate DL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.
AT+CGEQMIN =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Delivery order>
This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.
0 – no
1 – yes
2 – subscribed value
<Maximum SDU size>
This parameter indicates the maximum allowed SDU size inoctets.
The range is from 0 to 1520. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<SDU error ratio>
This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10
-3 would be specified as “5E3”(e.g.
AT+CGEQMIN =..,”5E3”,…).
“0E0” – subscribed value
“1E2”
“7E3”
“1E3”
“1E4”
“1E5”
“1E6”
“1E1”
<Residual bit error ratio>
This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered
SDUs.As an example a target residual bit error ratio of 5*10
-3
would be specified as “5E3”(e.g.
AT+CGEQMIN =…,”5E3”,..).
“0E0” – subscribed value
“5E2”
“1E2”
“5E3”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
“4E3”
“1E3”
“1E4”
“1E5”
“1E6”
“6E8”
<Delivery of erroneous SDUs>
This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
0 – no
1 – yes
2 – no detect
3 – subscribed value
<Transfer delay>
This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP,in milliseconds.
The range is from 0 to 4000. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Traffic handling priority>
This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS
Bearer compared to the SDUs of the other bearers.
The range is from 0 to 3. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
Examples
AT+CGEQMIN?
+CGEQMIN:
OK
AT+CGEQMIN=?
+CGEQMIN: "IP",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0","1E
1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E
4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
+CGEQMIN: "PPP",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0","1
E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1
E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
+CGEQMIN: "IPV6",(0-4),(0-384),(0-7168),(0-384),(0-7168),(0-2),(0-1520),("0E0","
1E1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","
1E4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
9.11
AT+CGDATA Enter data state
Description
The command causes the MT to perform whatever actions are necessary to establish communication between the TE and the network using one or more Packet Domain PDP types. This may include performing a PS attach and one or more PDP context activations.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGDATA=?
Write Command
AT+CGDATA=[ <L2P> ,[ <ci d> ]]
Responses
+CGDATA: (list of supported <L2P> s)
OK
Responses
CONNECT
NO CARRIER
OK
ERROR
+CME ERROR: <err>
Defined values
<L2P>
A string parameter that indicates the layer 2 protocol to be used between the TE and MT.
PPP Point-to-point protocol for a PDP such as IP
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT +CGDCONT command).
1…16
Examples
AT+CGDATA=?
+CGDATA: ("PPP")
OK
AT+CGDATA="PPP",1
CONNECT
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
9.12
AT+CGPADDR Show PDP address
Description
The write command returns a list of PDP addresses for the specified context identifiers.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGPADDR=?
Write Command
AT+CGPADDR=
<cid> [, <cid> [,…]]
Execution Command
AT+CGPADDR
Responses
+CGPADDR: (list of defined <cid> s)
OK
Responses
[+CGPADDR: <cid> , <PDP_addr> [<CR><LF>
+CGPADDR: <cid> , <PDP_addr> [...]]]
OK
ERROR
+CME ERROR: <err>
Responses
[+CGPADDR: <cid> , <PDP_addr> ]
+CGPADDR: <cid> , <PDP_addr> [...]]]
OK
ERROR
+CME ERROR: <err>
Defined values
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command). If no <cid> is specified, the addresses for all defined contexts are returned.
1…16
<PDP_addr>
A string that identifies the MT in the address space applicable to the PDP. The address may be static or dynamic. For a static address, it will be the one set by the AT+CGDCONT command when the context was defined. For a dynamic address it will be the one assigned during the last PDP context activation that used the context definition referred to by <cid> . <PDP_addr> is omitted if none is available.
Examples
AT+CGPADDR =?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CGPADDR: ( 1)
OK
AT+CGPADDR=1
+CGPADDR: 1,"0.0.0.0"
OK
9.13
AT+CGCLASS GPRS mobile station class
Description
This command is used to set the MT to operate according to the specified GPRS mobile class.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGCLASS=?
Read Command
AT+CGCLASS?
Write Command
AT+CGCLASS= <class>
Execution Command
AT+CGCLASS
Responses
+CGCLASS: (list of supported <class> s)
OK
ERROR
Responses
+CGCLASS: <class>
OK
ERROR
Responses
OK
ERROR
+CME ERROR: <err>
Responses
Set default value:
OK
ERROR
Defined values
<class>
A string parameter which indicates the GPRS mobile class (in descending order of functionality)
A – class A (highest)
Examples
AT+CGCLASS=?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CGCLASS: ("A")
OK
AT+CGCLASS?
+CGCLASS: "A"
OK
9.14
AT+CGEREP GPRS event reporting
Description
The write command enables or disables sending of unsolicited result codes, “+CGEV” from MT to
TE in the case of certain events occurring in the Packet Domain MT or the network.
<mode> controls the processing of unsolicited result codes specified within this command. <bfr> controls the effect on buffered codes when <mode> 1 or 2 is entered. If a setting is not supported by the MT,
ERROR or +CME ERROR: is returned.
Read command returns the current <mode> and buffer settings.
Test command returns the modes and buffer settings supported by the MT as compound values.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command
AT+CGEREP=?
Read Command
AT+CGEREP?
Write Command
AT+CGEREP=
<mode> [, <bfr> ]
Execution Command
AT+CGEREP
Responses
+CGEREP: (list of supported <mode> s),(list of supported <bfr> s)
OK
Responses
+CGEREP: <mode> , <bfr>
OK
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
Defined values
<mode>
0 – buffer unsolicited result codes in the MT; if MT result code buffer is full, the oldest ones can be discarded. No codes are forwarded to the TE.
1 – discard unsolicited result codes when MT-TE link is reserved (e.g. in on-line data mode); otherwise forward them directly to the TE.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
2 – buffer unsolicited result codes in the MT when MT-TE link is reserved (e.g. in on-line data mode) and flush them to the TE when MT-TE link becomes available; otherwise forward them directly to the TE.
<bfr>
0 – MT buffer of unsolicited result codes defined within this command is cleared when
<mode> 1 or 2 is entered.
1 – MT buffer of unsolicited result codes defined within this command is flushed to the TE when <mode> 1 or 2 is entered (OK response shall be given before flushing the codes).
The following unsolicited result codes and the corresponding events are defined:
+CGEV: REJECT <PDP_type> , <PDP_addr>
A network request for PDP context activation occurred when the MT was unable to report it to the TE with a +CRING unsolicited result code and was automatically rejected.
+CGEV: NW REACT <PDP_type> , <PDP_addr> , [ <cid> ]
The network has requested a context reactivation. The <cid> that was used to reactivate the context is provided if known to the MT.
+CGEV: NW DEACT <PDP_type> , <PDP_addr> , [ <cid> ]
The network has forced a context deactivation. The <cid> that was used to activate the context is provided if known to the MT.
+CGEV: ME DEACT <PDP_type> , <PDP_addr> , [ <cid> ]
The mobile equipment has forced a context deactivation. The <cid> that was used to activate the context is provided if known to the MT.
+CGEV: NW DETACH
The network has forced a Packet Domain detach. This implies that all active contexts have been deactivated. These are not reported separately.
+CGEV: ME DETACH
The mobile equipment has forced a Packet Domain detach. This implies that all active contexts have been deactivated. These are not reported separately.
+CGEV: NW CLASS <class>
The network has forced a change of MS class. The highest available class is reported
(see AT+CGCLASS ).
+CGEV: ME CLASS <class>
The mobile equipment has forced a change of MS class. The highest available class is reported (see AT+CGCLASS ).
Examples
AT+CGEREP=?
+CGEREP: (0-2),(0-1)
OK
AT+CGEREP?
+CGEREP: 0,0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
9.15
AT+CGAUTH Set type of authentication for PDP-IP connections of GPRS
Description
This command is used to set type of authentication for PDP-IP connections of GPRS.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CGAUTH=?
Read Command
AT+CGAUTH?
Write Command
AT+CGAUTH= <cid> [, <aut h_type> [, <passwd> [, <user> ]
]]
Execution Command
AT+CGAUTH
Responses
+CGAUTH:(range of supported <cid> s),(list of supported <auth _type> s),,
OK
ERROR
+CME ERROR: <err>
Responses
+CGAUTH: <cid> , <auth_type> [, <user>] <CR><LF>
+CGAUTH: <cid> , <auth_type> [, <user> ]<CR><LF>
…
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<cid>
Parameter specifies a particular PDP context definition. This is also used in other PDP context-related commands.
1…16
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<auth_type>
Indicate the type of authentication to be used for the specified context. If CHAP is selected another parameter <passwd> needs to be specified. If PAP is selected two additional parameters <passwd> and <user> need to specified.
0 – none
1 – PAP
2 – CHAP
3 – PAP or CHAP
<passwd>
Parameter specifies the password used for authentication.
<user>
Parameter specifies the user name used for authentication.
Examples
AT+CGAUTH=?
+CGAUTH: (1-16),(0-3),
OK
AT+CGAUTH=1,1,”123”,”SIMCOM”
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
10 AT Commands for SIM Application Toolkit
10.1
AT+STIN SAT Indication
Description
Every time the SIM Application issues a Proactive Command, via the ME, the TA will receive an indication. This indicates the type of Proactive Command issued.
AT+STGI must then be used by the TA to request the parameters of the Proactive Command from the ME. Upon receiving the +STGI response from the ME, the TA must send AT+STGR to confirm the execution of the Proactive Command and provide any required user response, e.g. a selected menu item.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+STIN=?
Read Command
AT+STIN?
Responses
OK
Responses
+STIN: <cmd_id>
OK
Unsolicited Result Codes
+STIN: <cmd_id>
Proactive Command notification
21 – display text
22 – get inkey
23 – get input
24 – select item
+STIN: 25
Notification that SIM Application has returned to main menu. If user doesn’t do any action in 2 minutes, application will return to main menu automatically.
Defined values
<cmd_id>
21 – display text
22 – get inkey
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
23 – get input
24 – select item
25 – set up menu
Examples
AT+STIN?
+STIN: 24
OK
10.2
AT+STGI Get SAT information
Description
Regularly this command is used upon receipt of an URC " +STIN " to request the parameters of the
Proactive Command. Then the TA is expected to acknowledge the AT+STGI response with
AT+STGR to confirm that the Proactive Command has been executed. AT+STGR will also provide any user information, e.g. a selected menu item. The Proactive Command type value specifies to which " +STIN " the command is related.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+STGI=?
Write Command
AT+STGI= <cmd_id>
Responses
OK
Responses
If <cmd_id> =10:
OK
If <cmd_id> =21:
+STGI:21, <prio> , <clear_mode> , <text_len> , <text>
OK
If <cmd_id> =22:
+STGI: 22, < rsp_format> , < help> , <text_len> , <text>
OK
If <cmd_id> =23:
+STGI:23, <rsp_format> , <max_len> , <min_len> , <help> , <show> , <t ext_len> , <text>
OK
If <cmd_id> =24:
+STGI:24, <help> , <softkey> , <present> , <title_len> , <title> , <item_n um>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<cmd_id>
21 – display text
22 – get inkey
23 – get input
24 – select item
25 – set up menu
<prio>
Priority of display text
0 – Normal priority
1 – High priority
<clear_mode>
0 – Clear after a delay
1 – Clear by user
<text_len>
Length of text
<rsp_format>
0 – SMS default alphabet
1 – YES or NO
2 – numerical only
3 – UCS2
<help>
0 – Help unavailable
1 – Help available
<max_len>
Maximum length of input
<min_len>
Minimum length of input
<show>
0 – Hide input text
1 – Display input text
<softkey>
0 – No softkey preferred
+STGI:24, <item_id> , <item_len> , <item_data>
[…]
OK
If <cmd_id> =25:
+STGI:25, <help> , <softkey> , <title_len> , <title> , <item_num>
+STGI:25, <item_id> , <item_len> , <item_data>
[...]
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
1 – Softkey preferred
<present>
Menu presentation format available for select item
0 – Presentation not specified
1 – Data value presentation
2 – Navigation presentation
<title_len>
Length of title
<item_num>
Number of items in the menu
<item_id>
Identifier of item
<item_len>
Length of item
<title>
Title in ucs2 format
<item_data>
Content of the item in ucs2 format
<text>
Text in ucs2 format.
Examples
AT+STGI=25 at+stgi=25
+STGI:25,0,0,10,"795E5DDE884C59295730",15
+STGI:25,1,8,"8F7B677E95EE5019"
+STGI:25,2,8,"77ED4FE17FA453D1"
+STGI:25,3,8,"4F1860E05FEB8BAF"
+STGI:25,4,8,"4E1A52A17CBE9009"
+STGI:25,5,8,"8D448D3963A88350"
+STGI:25,6,8,"81EA52A9670D52A1"
+STGI:25,7,8,"8F7B677E5F6994C3"
+STGI:25,8,8,"8BED97F367425FD7"
+STGI:25,9,10,"97F34E506392884C699C"
+STGI:25,10,8,"65B095FB59296C14"
+STGI:25,11,8,"94C358F056FE7247"
+STGI:25,12,8,"804A59294EA453CB"
+STGI:25,13,8,"5F005FC34F1195F2"
+STGI:25,14,8,"751F6D3B5E388BC6"
+STGI:25,21,12,"00530049004D53614FE1606F"
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
10.3
AT+STGR SAT respond
Description
The TA is expected to acknowledge the AT+STGI response with AT+STGR to confirm that the
Proactive Command has been executed. AT+STGR will also provide any user information, e.g. a selected menu item.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+STGR=?
Write Command
AT+STGR= <cmd_id> [, <dat a> ]
Responses
OK
Responses
OK
Defined values
<cmd_id>
22 – get inkey
23 – get input
24 – select item
25 – set up menu
83 – session end by user
84 – go backward
<data>
If <cmd_id> =22:
Input a character
If <cmd_id> =23:
Input a string.
If <rsp_format> is YES or NO, input of a character in case of ANSI character set requests one byte, e.g. “Y”.
If <rsp_format> is numerical only, input the characters in decimal number, e.g. “123”
If <rsp_faomat> is UCS2, requests a 4 byte string, e.g. “0031”
<rsp_faomat> refer to the response by AT+STGI =23
If <cmd_id> =24:
Input the identifier of the item selected by user
If <cmd_id> =25:
Input the identifier of the item selected by user
If <cmd_id>=83:
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<data> ignore
Note: It could return main menu during Proactive Command id is not 22 or 23
If <cmd_id>= 84:
<data> ignore
Examples
AT+STGR=25,1
OK
+STIN: 24
10.4
AT+STK STK Switch
Description
This command is used to disable or enable the STK function. If the argument is 1, it is enabled.
While if the argument is 0, it is disabled.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+STK=?
Read Command
AT+STK?
Write Command
AT+STK= <value>
Execution Command
AT+STK
Responses
+STK: (list of supported <value> s)
OK
Responses
+STK: <value>
OK
Responses
OK
ERROR
Responses
Set default value ( < value > =1):
OK
Defined values
<value>
0 – Disable STK
1 – Enable STK
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+STK=1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
11 AT Commands for Audio
11.1
AT+CSDVC Switch voice channel device
Description
This command is used to switch voice channel device. After changing current voice channel device and if there is a connecting voice call, it will use the settings of previous device (loudspeaker volume level, mute state of loudspeaker and microphone, refer to AT+CLVL , AT+VMUTE , and
AT+CMUT ).
NOTE: Use AT+CPCM command to enable PCM function and configure the mode that you want before setting AT+CSDVC=4 .
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSDVC=?
Read Command
AT+CSDVC?
Write Command
AT+CSDVC=
<dev> [, <save> ]
Responses
+CSDVC: (list of supported <dev> s),(list of supported <save> s)
OK
Responses
+CSDVC: <dev>
OK
Responses
OK
Defined values
<dev>
1 – handset
3 – speaker phone
4 – PCM interface
<save>
0 – temporary voice device setting, after reboot it will be resumed.
1 – permanent voice device setting.
NOTE: If subparameter <save> is omitted, voice device setting is temporary.
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CSDVC=1
OK
AT+CSDVC?
+CSDVC:1
OK
AT+CSDVC=1,1
OK
11.2
AT+CLVL Loudspeaker volume level
Description
Write command is used to select the volume of the internal loudspeaker audio output of the device.
Test command returns supported values as compound value.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
AT+CLVL=?
Read Command
AT+CLVL?
Write Command
AT+CLVL= <level>
Responses
+CLVL: (list of supported <level> s)
OK
Responses
+CLVL: <level>
OK
Responses
OK
ERROR
Defined values
<level>
Integer type value which represents loudspeaker volume level. The range is from 0 to 8, and 0 represents the lowest loudspeaker volume level, 2 is default factory value.
NOTE: <level> is nonvolatile, and it is stored when restart.
Examples
AT+CLVL?
+CLVL:2
OK
AT+CLVL=3
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
11.3
AT+CMICAMP1 Set value of micamp1
Description
This command is used to set audio path parameter – micamp1; With this command you can change the first stage of MIC amplify value based on your design separately. Please refer to related hardware design document for more information.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CMICAMP1=?
Read Command
AT+ CMICAMP1?
Write Command
AT+CMICAMP1=
<amp_val>
Responses
+CMICAMP1: (list of supported <amp_val> s)
OK
Responses
+CMICAMP1: <amp_val>
OK
Responses
OK
ERROR
Defined values
<amp_val>
Amplify value number which is from 0 to 1. 0 is 0DB and 1 is 24DB.
Examples
AT+CMICAMP1=0
+CMICAMP1: 0
OK
AT+CMICAMP1?
+CMICAMP1: 0
OK
AT+ CMICAMP1=?
+CMICAMP1: (0-1)
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
11.4
AT+CPTONE Play tone
Description
This command is used to play a DTMF tone or complex tone on local voice channel device which is selected by
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CPTONE=?
Write Command
AT+CPTONE= <tone>
Responses
+CPTONE: (list of supported <tone> s)
OK
Responses
OK
[+RXDTMF: <key> ] (when <tone> is between 1 and 16)
Defined values
<tone>
0 – Stop the sound tone
1 – DTMF tone for 1 key, duration 100ms
2 – DTMF tone for 2 key, duration 100ms
3 – DTMF tone for 3 key, duration 100ms
4 – DTMF tone for 4 key, duration 100ms
5 – DTMF tone for 5 key, duration 100ms
6 – DTMF tone for 6 key, duration 100ms
7 – DTMF tone for 7 key, duration 100ms
8 – DTMF tone for 8 key, duration 100ms
9 – DTMF tone for 9 key, duration 100ms
10 – DTMF tone for 0 key, duration 100ms
11 – DTMF tone for A key, duration 100ms
12 – DTMF tone for B key, duration 100ms
13 – DTMF tone for C key, duration 100ms
14 – DTMF tone for D key, duration 100ms
15 – DTMF tone for # key, duration 100ms
16 – DTMF tone for * key, duration 100ms
17 – Subscriber busy sound, duration always
18 – Congestion sound, duration always
19 – Error information sound, duration 1330*3ms
20 – Number unobtainable sound, duration 1330*3ms
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
21 – Authentication failure sound, duration 1330*3ms
22 – Radio path acknowledgement sound, duration 700*1ms
23 – Radio path not available sound, duration 400*4ms
24 – CEPT call waiting sound, duration 4000*2ms
25 – CEPT ringing sound, duration always
26 – CEPT dial tone, duration always
<key>
1 – <tone> value 1
2 – <tone> value 2
3 – <tone> value 3
4 – <tone> value 4
5 – <tone> value 5
6 – <tone> value 6
7 – <tone> value 7
8 – <tone> value 8
9 – <tone> value 9
0 – <tone> value 10
A – <tone> value 11
B – <tone> value 12
C – <tone> value 13
D – <tone> value 14
# – <tone> value 15
* – <tone> value 16
Examples
AT+CPTONE= ?
+CPTONE:(0-26)
OK
AT+CPTONE=17
OK
11.5
AT+CPTONEEXT Play tone extension interface
Description
This command is used to play a tone on local voice channel device which is selected by
AT+CSDVC .
SIM PIN References
NO Vendor
Syntax
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Test Command
AT+CPTONEEXT=?
Responses
+CPTONE: (list of supported <tone> s)
OK
Write Command Responses
AT+CPTONEEXT= <tone> OK
Execution Command
AT+CPTONEEXT
Responses
OK (Stop the sound tone)
Defined values
<tone>
0 – Ring for incoming call
1 – Wake-up/Power-up sound
2 – Dial tone
3 – DTACO roaming dial tone
4 – Ring-back sound
5 – Send request intercepted locally
6 – System busy
7 – Busy Signal
8 – Confirmation Tone
9 – Call Waiting
10 – Answer Tone
11 – Off-Hook Warning
12 – Normal Alerting
13 – Intergroup Alerting
14 – Special/Priority Alerting
15 – Ping ring
16 – IS-54B High Long
17 – IS-54B High Short-short
18 – IS-54B High Short-short-long
19 – IS-54B High Short-short-2
20 – IS-54B High Short-long-short
21 – IS-54B High Short-short-short-short
22 – IS-54B High PBX Long
23 – IS-54B High PBX Short-short
24 – IS-54B High PBX Short-short-long
25 – IS-54B High PBX Short-long-short
26 – IS-54B High PBX Short-short-short-short
27 – IS-53A High Pip-Pip-Pip-Pip Alert
28 – IS-54B Medium Long
29 – IS-54B Medium Short-short
30 – IS-54B Medium Short-short-long
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
31 – IS-54B Medium Short-short-2
32 – IS-54B Medium Short-long-short
33 – IS-54B Medium Short-short-short-short
34 – IS-54B Medium PBX Long
35 – IS-54B Medium PBX Short-short
36 – IS-54B Medium PBX Short-short-long
37 – IS-54B Medium PBX Short-long-short
38 – IS-54B Medium PBX Short-short-short-short
39 – IS-53A Medium Pip-Pip-Pip-Pip Alert
40 – IS-54B Low Long
41 – IS-54B Low Short-short
42 – IS-54B Low Short-short-long
43 – IS-54B Low Short-short-2
44 – IS-54B Low Short-long-short
45 – IS-54B Low Short-short-short-short
46 – IS-54B Low PBX Long
47 – IS-54B Low PBX Short-short
48 – IS-54B Low PBX Short-short-long
49 – IS-54B Low PBX Short-long-short
50 – IS-54B Low PBX Short-short-short-shrt
51 – IS-53A Low Pip-Pip-Pip-Pip Alert
52 – Tone to inform user of a fade
53 – Inform user of a service area change
54 – Horn alert
55 – Abbreviated System busy
56 – Abbrev'd Send request intercepted locally
57 – Alternate reorder
58 – Message Waiting Signal
59 – Abbreviated alert
60 – Pip Tone (Voice Mail Waiting)
61 – Ringing option while roaming
62 – Service acquired sound
63 – Service lost sound
64 – Change to a more preferred service sound
65 – Change to a less preferred service sound
66 – External power on sound
67 – External power off sound
68 – User selectable ring 1
69 – User selectable ring 2
70 – User selectable ring 3
71 – User selectable ring 4
72 – User selectable ring 5
73 – User selectable ring 6
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
74 – User selectable ring 7
75 – User selectable ring 8
76 – User selectable ring 9
77 – Call answer sound when in HFK
78 – Call origination sound when in HFK
79 – Special info soundGSM tonesdefined in 3GPP 2.40
80 – Subscriber busy sound
81 – Congestion sound
82 – Error information sound
83 – Number unobtainable sound
84 – Authentication failure sound
85 – Radio path acknowledgement sound
86 – Radio path not available sound
87 – CEPT call waiting sound
88 – CEPT ringing sound
89 – CEPT dial tone
90 – British busy sound
Examples
AT+CPTONEEXT=0
OK
11.6
AT+CTXGAIN Set TX gain
Description
This command is used to set audio path parameter – TX gain, and refer to related hardware design document to get more information.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CTXGAIN=?
Responses
+CTXGAIN: (list of supported <tx_gain> s)
OK
Read Command
AT+CTXGAIN?
Responses
+CTXGAIN: <tx_gain>
Write Command
OK
Responses
AT+CTXGAIN= <tx_gain> OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<tx_gain>
TX gain level which is from 0 to 65535.
Examples
AT+CTXGAIN=1234
OK
11.7
AT+CRXGAIN Set RX gain
Description
This command is used to set audio path parameter – RX gain, and refer to related hardware design document to get more information.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CRXGAIN=?
Responses
+CRXGAIN: (list of supported <rx_gain> s)
OK
Responses Read Command
AT+CRXGAIN? +CRXGAIN: <rx_gain>
OK
Write Command Responses
AT+CRXGAIN= <rx_gain> OK
Defined values
<rx_gain>
RX gain level which is from 0 to 65535.
Examples
AT+CRXGAIN=1234
OK
11.8
AT+CTXVOL Set TX volume
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to set audio path parameter – TX volume, and refer to related hardware design document to get more information.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CTXVOL=?
Read Command
AT+CTXVOL?
Write Command
AT+CTXVOL= <tx_vol>
Responses
+CTXVOL: (list of supported <tx_vol> s)
OK
Responses
+CTXVOL: <tx_vol>
OK
Responses
OK
Defined values
<tx_vol>
TX volume level which is from 0 to 65535.
Examples
AT+CTXVOL=1234
OK
11.9
AT+CRXVOL Set RX volume
Description
This command is used to set audio path parameter – RX volume, and refer to related hardware design document to get more information.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CRXVOL=?
Read Command
Responses
+CRXVOL: (list of supported <rx_vol> s)
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CRXVOL?
Write Command
AT+CRXVOL= <rx_vol>
+CRXVOL: <rx_vol>
OK
Responses
OK
Defined values
<rx_vol>
RX volume level which is from -100 to 100.
Examples
AT+CRXVOL=12
OK
11.10
AT+CTXFTR Set TX filter
Description
This command is used to set audio path parameter – TX filter, and refer to related hardware design document to get more information.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CTXFTR=?
Read Command
AT+CTXFTR?
Write Command
AT+CTXFTR=
<tx_ftr_ 1 > , <…> , <tx_ftr_ 7 >
Responses
+CTXFTR: (list of supported <tx_ftr_ N > s)
OK
Responses
+CTXFTR: <tx_ftr_ 1 > , <…> , <tx_ftr_ 7 >
OK
Responses
OK
Defined values
<tx_ftr_ N >
TX filter level which is from 0 to 65535. ( N is from 1 to 7)
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CTXFTR=1111,2222,3333,4444,5555,6666,7777
OK
11.11
AT+CRXFTR Set RX filter
Description
This command is used to set audio path parameter – RX filter, and refer to related hardware design document to get more information.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CRXFTR=?
Read Command
AT+CRXFTR?
Write Command
AT+CRXFTR=
<rx_ftr_ 1 > , <…> , <rx_ftr_ 7 >
Responses
+CRXFTR: (list of supported <rx_ftr_ N > s)
OK
Responses
+CRXFTR: <rx_ftr_ 1 > , <…> , <rx_ftr_ 7 >
OK
Responses
OK
Defined values
<rx_ftr_ N >
RX filter level which is from 0 to 65535. ( N is from 1 to 7)
Examples
AT+CRXFTR=1111,2222,3333,4444,5555,6666,7777
OK
11.12
AT+CVLVL Set value of sound level
Description
This command is used to set audio path parameter – RX volume. This command is different from CRXVOL (command CRXVOL will modify the values of all sound levels offset we provided together). You can change the value of each sound level based on your design separately through this command.
Please refer to related hardware design document for more information.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CVLVL=?
Read Command
AT+CVLVL?
Write Command
AT+CVLVL= <lvl> , <lvl_val ue>
Responses
+CVLVL: (list of supported <lvl> s),(list of supported <lvl_va lue> s)
OK
Responses
+CVLVL: <lvl_value1> , <lvl_value2> , <lvl_value3> , <lvl_value4> ,
<lvl_value5> , <lvl_value6> , <lvl_value7> , <lvl_value8>
OK
Responses
+CVLVL: lvl_value
OK
ERROR
Defined values
<lvl>
Sound level number which is from 1 to 8.
<lvl_value>
Sound level value which is from -5000 to 5000.
<lvl_value1>
Sound level value that sound level number equals 1.
<lvl_value2>
Sound level value that sound level number equals 2.
<lvl_value3>
Sound level value that sound level number equals 3.
<lvl_value4>
Sound level value that sound level number equals 4.
<lvl_value5>
Sound level value that sound level number equals 5.
<lvl_value6>
Sound level value that sound level number equals 6.
<lvl_value7>
Sound level value that sound level number equals 7.
<lvl_value8>
Sound level value that sound level number equals 8.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CVLVL=1,-2000
+CVLVL: -2000
OK
AT+CVLVL?
+CVLVL: -2000,-200,500,1000
OK
AT+ CVLVL=?
+CVLVL: (1-8),(-5000-5000)
OK
NOTE: Currently level 7 and level 8 are the same, which means the value set for one level also will set for the other automatically(they have the same values).
11.13
AT+SIDET Digital attenuation of sidetone
Description
This
command is used to set digital attenuation of sidetone. Please refer to related hardware design document for more information.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+SIDET=?
Read Command
AT+SIDET?
Write Command
AT+SIDET= <st>
Responses
+SIDET: (list of supported <st> s)
OK
Responses
+SIDET: <st>
OK
Responses
OK
ERROR
Defined values
<st>
Digital attenuation of sidetone, integer type in decimal format and nonvolatile
.
Range: from 0 to 65535.
Factory value: HANDSET:4000, HEADSET:9472, SPEAKER PHONE:16384.
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CSDVC=1
OK
AT+SIDET?
+SIDET: 4000
OK
11.14
AT+CECM Enable/Disable Echo Canceller
Description
This command is used to select the echo cancellation mode. Each audio channel has own default echo cancellation mode. For example:
Handset: at+cecm=1(default open)
Headset: at+cecm=2(default open)
Speaker: at+cecm=4(default open)
PCM: at+cecm=5(default open)
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CECM=?
Read Command
AT+CECM?
Write Command
AT+CECM= <enable>
Responses
+CECM: (list of supported <enable> s)
OK
Responses
+CECM: <enable>
OK
Responses
OK
ERROR
Defined values
<enable>:
0 : disable EC mode
1 : EC mode recommended for HANDSET
2 : EC mode recommended for HEADSET
3 : EC mode recommended for HANDSFREE
4 : EC mode recommended for SPEAKER
5 : EC mode recommended for BT HEADSET
6 : EC mode recommended for aggressive SPEAKER
7 : EC mode recommended for medium SPEAKER
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
8 : EC mode recommended for least aggressive SPEAKER
NOTE:
1. EC mode of 6, 7, 8 can be adjusted by AT+CECSET command
2. User should use this AT command together with other related audio AT commands like
“AT+CSDVC ”, “AT+CPCM” and so on.
Examples
AT+CECM=0
OK
AT+ CECM =1
OK
11.15
AT+CNSM Enable/Disable Noise Suppression
Description
This command is used to enable/disable noise suppression. The default value is enabled.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CNSM=?
Read Command
AT+CNSM?
Write Command
AT+CNSM= <enable>
Responses
+CNSM: (list of supported <enable> s)
OK
Responses
+CNSM: <enable>
OK
Responses
OK
ERROR
Defined values
<enable>:
0 : disable this feature
1 : enable this feature
NOTE: User should use this AT command together with other related audio AT commands like
“AT+CSDVC ”, “AT+CPCM” and so on.
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CNSM=0
OK
AT+ CNSM =1
OK
11.16
AT+CECSET Adjust the effect for the given echo cancellation mode
Description
This command is used to adjust the parameters of the selected EC mode for the given device. It can be used together with AT+CECM command.
This configuration will be saved automatically.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CECSET=?
Read Command
AT+CECSET?
Write Command
AT+CECSET
= <index> , <value>
Responses
+CECSET: (list of supported <index> s), (list of supported
<value> s)
OK
Responses
+CECSET: current echo cancellation mode is : <ec_md>
<index> -> <value>
[…]
OK
Responses
OK
ERROR
Defined values
<ec_md>:
Current echo cancellation mode, please refer AT+CECM for more details
<index>:
0 – 37, EC has 38 parameters; this is the index of the selected parameter.
<value>:
0 – 65535, EC parameter value.
NOTE:
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
1. Currently only three EC mode’s parameters can be adjusted, they are 6, 7 and 8 you can use
AT+CECM to select one of these modes.
2. You have to use AT+CECM to select the right EC mode first in order to change the parameters.
Examples
AT+CSDVC=1
OK
AT+CECM=6
OK
AT+CECSET=0,65530
OK
AT+CECSET=1,1000
OK
11.17
AT+CEXTERNTONE Enable or disable MIC
Description
This command is used to enable or disable MIC.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CEXTERNTONE=?
Read Command
AT+ CEXTERNTONE?
Write Command
AT+CEXTERNTONE= <mode>
Responses
OK
Responses
+CEXTERNTONE: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
0 – enable MIC
1 – disable MIC
Examples
AT+ CEXTERNTONE =?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+ CEXTERNTONE =1
OK
AT+ CEXTERNTONE ?
+ CEXTERNTONE : 1
OK
11.18
AT+CPCMREG Control PCM data transfer by diagnostics port
Description
This command is used to control PCM data transfer by diagnostics port.First you should set diag- nostics port as data mode by AT+DSWITCH .
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CPCMREG=?
Read Command
AT+CPCMREG?
Write Command
AT+CPCMREG= <n>
Responses
+CPCMREG: (list of supported <n> s)
OK
Responses
+CPCMREG: <n>
OK
Responses
OK
ERROR
Defined values
<n>
Switch PCM data transfer by diagnostics port on/off
0 Disable PCM data transfer by diagnostics port
1 Enable PCM data transfer by diagnostics port
Examples
AT+CPCMREG=?
+CPCMREG: (0-1)
OK
AT+CPCMREG?
+CPCMREG: 0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CPCMREG=1
OK
11.19
AT+CPCMFRM Configure USB audio PCM frame format
Description
This command is used to configure the sample rate of USB audio PCM input/output.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CPCMFRM=?
Read Command
AT+CPCMFRM?
Write Command
AT+CPCMFRM= <rate>
Responses
+CPCMFRM: (list of supported <rate> s)
OK
Responses
+CPCMFRM: <rate>
OK
Responses
OK
ERROR
Defined values
<rate>
0 – 8 kHz sample rate, 320 bytes per 20 ms.
1 – 16 kHz sample rate, 640 bytes per 20 ms.
Examples
AT+CPCMFRM=1
OK
AT+CPCMFRM?
+CPCMFRM: 1
OK
11.20
AT+CPCM External PCM codec mode configuration
Description
This command is used to enable PCM or disable PCM function. And configure different PCM mode. Because the PCM pins are multiplex on GPIO, it will switch the function between GPIO and
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
PCM.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CPCM=?
Read Command
AT+CPCM?
Write Command
AT+CPCM= <arg_1> [, <arg_
2> ]
Responses
+CPCM: (list of supported <arg_1> s), (list of supported <arg_2> s)
OK
Responses
+CPCM: <arg_1> , <arg_2>
OK
Responses
OK
Defined values
<arg_1>
0 – disable PCM, switch to common GPIOs.
1 – enable PCM, switch to PCM function.
<arg_2>
0 – Auxiliary master PCM, 128K clock and 8K synchronize clock.
1 – Primary master PCM, 2M clock and 8K synchronize clock...
2 – Primary slave PCM, clock provided by external codec.
Examples
AT+CPCM=1
OK
AT+CPCM=?
+CPCM : (0-1),(0-2)
OK
AT+CPCM?
+CPCM : 1,1
OK
11.21
AT+CPCMS Enable/Disable the PCM clock and sync output
Description
This command is used to open / close the pcm CLOCK and SYNC signal output, with this command one can control the CLOK and SYNC at any time (even if no call happened).
NOTE: PCM interface will enabled automatically when a call is happened, so one needs not to use this command manually if PCM is only used during the call process.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CPCMS=?
Read Command
AT+CPCMS?
Write Command
AT+CPCMS= <switch>
Responses
+CPCMS: (0,1)
OK
Responses
+CPCMS: <switch>
OK
Responses
OK
ERROR
Defined values
< switch >
0 – disable CLOCK and SYNC output.
1 – enable CLOCK and SYNC output.
Examples
AT+CPCMS=1
OK
11.22
AT+CPCMFMT Change the PCM format
Description
This command is used to change the current PCM format, there are 3 formats currently supported: linear, u-law, a-law
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CPCMFMT=?
Read Command
AT+CPCMFMT?
Responses
+CPCMFMT: (list of supported <format> s)
OK
Responses
+CPCMFMT: <format>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
AT+CPCMFMT= <format>
OK
Responses
OK
ERROR
Defined values
<format>
0 u-law
1 a-law
2 linear
Examples
AT+CPCMFMT=?
+CPCMFMT: (0-2)
OK
AT+CPCMFMT?
+CPCMFMT: 1
OK
AT+CPCMFMT=2
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
12 AT Commands for Hardware
12.1
AT+CRIIC Read values from register of IIC device
Description
This command is used to read values from register of IIC device.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CRIIC=?
Write Command
AT+CRIIC=
<addr>,<reg> , <len>[,<opt>]
Responses
OK
Responses
+CRIIC: <data>
OK
ERROR
Defined values
<addr>
Device address. Input format must be hex, such as 0xFF.
<reg>
Register address. Input format must be hex, such as 0xFF.
<len>
Read length. Range:1-4; unit:byte.
<data>
Data read. Input format must be hex, such as 0xFF – 0xFFFFFFFF.
<opt>
Bit definitions for use in options byte in the I/O, the default value is 0x44:
0x01 – Use default address for I/O
0x02 – Use 16 bit addresses for Memory device
0x04 – Use 8 bit register based device
0x08 – NACK last byte read from slave
0x10 – Reserved
0x20 – During a read transaction, gen a repeated START after writing the slave address
(just before read)
0x40 – During a read transaction, gen a STOP & START after writing the slave address
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
(just before read)
0x80 – Generate a clock and a START before every I/O operation
Examples
AT+CRIIC=0x0F, 0x0F, 2
+CRIIC: FFFF
OK
12.2
AT+CWIIC Write values to register of IIC device
Description
This command is used to write values to register of IIC device.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CWIIC=?
Write Command
AT+CWIIC=
<addr> , <reg> , <data> , <len>[,
<opt>]
Responses
OK
Responses
OK
ERROR
Defined values
<addr>
Device address. Input format must be hex, such as 0xFF.
<reg>
Register address. Input format must be hex, such as 0xFF.
<len>
Read length. Range: 1-4; unit: byte.
<data>
Data written. Input format must be hex, such as 0xFF – 0xFFFFFFFF.
<opt>
Bit definitions for use in options byte in the I/O, the default value is 0x44:
0x01 – Use default address for I/O
0x02 – Use 16 bit addresses for Memory device
0x04 – Use 8 bit register based device
0x08 – NACK last byte read from slave
0x10 – Reserved
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0x20 – During a read transaction, generate a repeated START after writing the slave address (just before read)
0x40 – During a read transaction, generate a STOP & START after writing the slave address (just before read)
0x80 – Generate a clock and a START before every I/O operation
Examples
AT+CWIIC=0x0F, 0x0F, 0x1234, 2
+CWIIC: 0x1234
OK
12.3
AT+CSPISETCLK SPI clock rate setting
Description
This command is used to set SPI clock configuration and trigger mode.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSPISETCLK=?
Read Command
AT+CSPISETCLK?
Write Command
AT+CSPISETCLK= <polarit y> , <mode> , <trigger mode>
Responses
+CSPISETCLK: (range of supported <polarity> s), (range of su pported <mode> s),(range of supported <trigger mode> s)
OK
Responses
+
CSPISETCLK: <polarity> , <mode> , <trigger mode>
OK
Responses
OK
ERROR
Defined values
<polarity>
0 the SPI clock signal is low when the clock is idle
1 the SPI clock signal is high when the clock is idle
<mode>
0 the SPI clock runs only during a transfer unit
1 the SPI clock runs continuously from the start of the transfer
<trigger mode>
0 the SPI data input signal is sampled on the leading clock edge
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
1 the SPI data input signal is sampled on the trailing clock edge
Examples
AT+CSPISETCLK =1,0,1
OK
AT+CSPISETCLK?
+CSPISETCLK: 1,0,1
OK
AT+CSPISETCLK=?
+CSPISETCLK: (0-1),(0-1),(0-1)
OK
12.4
AT+CSPISETCS SPI chip select setting
Description
This command is used to set SPI chip select polarity and mode.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSPISETCS=?
Read Command
AT+CSPISETCS?
Write Command
AT+CSPISETCS= <mode> , < polarity>
Responses
+CSPISETCS: (range of supported <mode> s), (range of suppor ted <polarity> s)
OK
Responses
+CSPISETCS: <mode> , <polarity>
OK
Responses
OK
ERROR
Defined values
<mode>
0 the SPI chip select is de-asserted between transfer units
1 the SPI chip select is kept asserted between transfer units
<polarity>
0 the SPI chip select is active low
1 the SPI chip select is active high
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CSPISETCS =1,0
OK
AT+CSPISETCS?
+CSPISETCS: 1,0
OK
AT+CSPISETCS =?
+CSPISETCS: (0-1),(0-1)
OK
12.5
AT+CSPISETF SPI clock frequency setting
Description
This command is used to set SPI clock frequency
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSPISETF=?
Read Command
AT+CSPISETF?
Write Command
AT+CSPISETF= <min> , <ma x> , <de-assertion time>
Responses
+CSPISETF: (range of supported <min> s), (range of supported
<max> s),(range of supported <de-assertion time> s)
OK
Responses
+CSPISETF: <min> , <max> , <de-assertion time>
OK
Responses
OK
ERROR
Defined values
<min>
In master mode, set the minimum SPI clock frequency by the slave device
0…26000000
<max>
In master mode, set the maximum SPI clock frequency by the slave device
0…26000000
<de-assertion time>
In master mode, set the minimum time to wait between transfer units in nanoseconds
0…64
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CSPISETF =960000,10000000,0
OK
AT+CSPISETF?
+CSPISETF: 960000,10000000,0
OK
AT+CSPISETF =?
+CSPISETF: (0-26000000), (0-26000000),(0-64)
OK
12.6
AT+CSPISETPARA SPI transfer parameters setting
Description
This command is used to set SPI transfer parameters
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSPISETPARA=?
Read Command
AT+CSPISETPARA?
Write Command
AT+CSPISETPARA= <bit> ,
<input packed> , <output un packed>
Responses
+CSPISETPARA: (range of supported <bit> s), (range of suppo rted <input packed> s),(range of supported <output unpacked> s)
OK
Responses
+CSPISETPARA: <bit> , <input packed> , <output unpacked>
OK
Responses
OK
ERROR
Defined values
<bit> set the number of bits to use per transfer unit, only support 8,16,32 bits
0…32
<input packed>
0 data should be not packed into the user input buffer
1 data should be packed into the user input buffer
<output unpacked>
0 data should be not packed from the user output buffer
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
1 data should be packed from the user output buffer
Examples
AT+CSPISETPARA =16,0,1
OK
AT+CSPISETPARA?
+CSPISETPARA:16,0,1
OK
AT CSPISETPARA=?
+CSPISETPARA : (0-32), (0-1),(0-1)
OK
12.7
AT+CSPIW Write data to SPI
Description
This command is used to write data to SPI.
NOTE: If you want to write data only when you use SPI to connect to some special slave device, you can set <reg> to 0xFFFF.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSPIW=?
Write Command
AT+CSPIW= <reg> , <data> , < len>
Responses
OK
Responses
OK
ERROR
Defined values
<reg>
Register address. Input format must be hex, such as 0xFF.
<data>
Data written. Input format must be hex, such as 0xFF – 0xFFFFFFFF.
<len>
Read length.The unit is byte
1…4
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CSPIW=
0x0F, 0x1234, 2
OK
12.8
AT+CSPIR Read data from SPI
Description
This command is used to read data from SPI.
NOTE: If you want to read data only when you use SPI to connect to some special slave device, you can set <reg> to 0xFFFF.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSPIR=?
Write Command
AT+CSPIR=
<reg> , <len>
Responses
OK
Responses
+
CSPIR
: <data>
OK
ERROR
Defined values
<reg>
Register address. Input format must be hex, such as 0xFF.
<data>
Data read. Input format must be hex, such as 0xFF – 0xFFFFFFFF.
<len>
Read length.The unit is byte.
1…4
Examples
AT+CSPIR =
0x0F, 2
+
CSPIR
: 0x1234
OK
12.9
AT+CGFUNC Enable/Disable the function for the special GPIO.
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM5310 supplies many GPIOs, all of which can be used as General Purpose Input/Output pin, interrupt pin and some of them can be used as function pin.
This command is used to enable/disable the function for the special GPIO. Please consult the document “SIM5320_GPIO_Application_note” for more details.
The configuration will be saved automatically.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CGFUNC=?
Read Command
AT+CGFUNC= <function>
Write Command
AT+CGFUNC= <function> ,
<switch>
Responses
+CGFUNC: (list of supported <function> s),(list of supported
<switch> s)
OK
Responses
+CGFUNC: <switch>
OK
ERROR
Responses
OK
ERROR
Defined values
<function>
1 : function status led.
2 : function wakeup me
3 : function wakeup host
4 : function pcm
7 : function keypad
9 : function rf switch
10 : function uart1 dcd
11 : function uart1 flow control
12: function wake up SIM5310 module by GPIO43
13: function wake up host by GPIO41
14:function module power up status(GPIO40)
17:function RI line 2G mode control, please see the detail from NOTE
18:function UART DTR sleep mode
19:function used to control status led dynamically (use +CLEDDYNC)
<switch>
0 : disable the function.
1 : enable the function
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CGFUNC=1,1
OK
AT+CGFUNC=1
+CGFUNC: 1
OK
NOTE:
1 .Not all of the Modules of SIM5XXX series have the whole upper functions; some may have camera function while others may have keypad function and so on, please refer the Module SPEC for more details.
2. If AT+CGFUNC=17,1 then assert 60ms when have urc reported;assert 120m when have sms received;and always asserted during the ring(incoming call).
12.10
AT+CGPIO Set GPIO0 interrupt trigger mode
Description
This command is used to set GPIO0 interrupt trigger mode.
SIM PIN References
NO Vendor
Syntax
Write Command
AT+CGPIO= <detect> ,
<polarity> [, <save> ]
Responses
OK
ERROR
Defined values
<detect>
0 – LEVEL trigger mode
1 – EDGE trigger mode
<polarity>
0 – trigger when low level
1 – trigger when high level
<save>
0 – not save the setting
1 – save the setting
NOTE: If the parameter of <save> is omitted, it will save the setting.
Examples
AT+CGPIO=1,1,0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
12.11
AT+CGDRT Set the direction of specified GPIO
Description
This command is used to set the specified GPIO to input or output state.
If setting to input state, then this GPIO can not be set to high or low value.
SIM PIN References
NO Vendor
Syntax
Write Command
AT+CGDRT= <gpio_num> ,
<gpio_io> [, <save> ]
Responses
OK
ERROR
Defined values
<gpio_num>
0 – GPIO0
2 – GPIO2
3 – GPIO3
5 – GPIO5
<gpio_io>
0 – in
1 – out
<save>
0 – not save the setting
1 – save the setting
NOTE: If the parameter of <save> is omitted, it will save the direction of specified GPIO.
Examples
AT+CGDRT=3,0,0
OK
12.12
AT+CGSETV Set the value of specified GPIO
Description
This command is used to set the value of the specified GPIO to high or low.
SIM PIN References
NO Vendor
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Write Command
AT+CGSETV= <gpio_num> ,
<gpio_hl> [, <save> ]
Responses
OK
ERROR
Defined values
<gpio_num>
0 – GPIO0
2 – GPIO2
3 – GPIO3
5 – GPIO5
<gpio_hl>
0 – low
1 – high
<save>
0 – not save the setting
1 – save the setting
NOTE: If the parameter of <save> is omitted, it will save the value of specified GPIO.
Examples
AT+CGSETV=3,0,0
OK
12.13
AT+CGGETV Get the value of specified GPIO
Description
This command is used to get the value (high or low) of the specified GPIO.
SIM PIN References
NO Vendor
Syntax
Write Command
AT+CGGETV= <gpio_num>
Responses
+CGGETV: <gpio_hl>
OK
ERROR
Defined values
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<gpio_num>
0 – GPIO0
1 – GPIO1
2 – GPIO2
3 – GPIO3
4 – GPIO4
5 – GPIO5
<gpio_hl>
0 – low
1 – high
Examples
AT+CGGETV=3
+CGGETV: 0
OK
12.14
AT+CGISR Set GPIO interrupt trigger condition
Description
The module supplies many GPIOs, all of which can be used as General Purpose Input/Oupt pin, interrupt pin and some of them can be used as function pin.
This command is used to set one GPIO pin as an interrupt source, and then set the detect type[optional] and polarity type[optional], and enable interrupt. Please refer to the document
“SIMCom_3G_GPIO_Application_Note_V1.1.doc” for details.
SIM PIN References
No
Syntax
Read Command
AT+CGISR=< GPIO >
Write Command
AT+CGISR= < GPIO
> ,< detect >,< polarity >
Defined values
< GPIO >
GPIO number.
< detect >
Responses
+CGISR: < GPIO >[< detect >,< polarity >]
OK
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0 – level detection.
1 – edge detection
< polarity >
0 – low level/edge detection
1 – high level/edge detection
Examples
AT+CGISR=1
+CGISR : 1[0,1]
OK
AT+CGISR=1,0,1
OK
NOTE:
1. if the interruption is triggered SIM52XX will send the following URC to host.
2.
Default < detect > is 0 and default < polarity > is 1.
3.
After setting one GPIO pin as an interrupt source successfully, the setting will be saved.
12.15
AT+CGWHOST Reset GPIO 41 to high level
Description
This command resets GPIO41 to high lever after waking up the HOST.
GPIO41 status:
Low level: Wake up the HOST.
High level: the default status, and HOST use this AT to reset GPIO41 to high level.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CGWHOST
Examples
AT+CGWHOST
OK
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
12.16
AT+CGWISRMD Configure the trigger condition for GPIO43’s
Description
This command is used to set the appropriate trigger condition for GPIO43’s interrupt, which will finally waking up the module.
The interrupt is low level triggered by default.
NOTE: Before using this AT to set triggered mode, please use “AT+CGFUNC=12,0” to disable the function of GPIO43’s interrupt. After setting triggered mode, then use “AT+CGFUNC=12,1” to enable this function.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CGWISRMD=?
Read Command
AT+CGWISRMD?
Write Command
AT+CGWISRMD
= <detect> , <polarity>
Responses
+CGWISRMD: (list of supported <detect> s),(list of supported
<polarity> s)
OK
Responses
+CGWISRMD: <detect> , <polarity>
OK
Responses
OK
ERROR
Defined values
<detect>
0 Level trigger
1 Edge trigger
<polarity>
0 Low trigger
1 High trigger
Examples
AT+CGWISRMD=0,1
OK
AT+CGWISRMD=0,0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
12.17
AT+CRFEN Enable/Disable RF checking
Description
This command is used to enable or disable RF checking function during the startup process.
This configuration will take effect after reboot.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CRFEN=?
Read Command
AT+CRFEN?
Write Command
AT+CRFEN= <value>
Responses
+CRFEN: (list of supported <value> s)
OK
Responses
+CRFEN: <value>
OK
Responses
OK
ERROR
Defined values
<value>
0 – disable RF checking function when startup
1 – enable RF checking function when startup
Examples
AT+CRFEN=1
OK
AT+CRFEN?
+CRFEN: 1
OK
AT+CRFEN=?
+CRFEN : (0-1)
OK
12.18
AT+SJDR Jamming detection
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to open or close jamming detection. When jamming is detected, URC will be reported at 470ms intervals. When no jamming, URC will be reported once. If one unused GPIO is assigned to JAMMING detection, it will be set to high level for indicating jamming when jamming is detected. Conversely, it will be set to low level for indicating no jamming.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+SJDR=?
Read Command
AT+ SJDR?
Write Command
AT+SJDR= <op_code>
,
<report_mode>[,
<GPIO_num>]
Responses
+SJDR: (0,1)
OK
Responses
+SJDR: <op_code>,<report_mode>[,<GPIO_num>]
OK
Responses
OK
+SJDR: < URC_percentage >
OK
ERROR
Defined values
< op_code >
Operate code.
0 – close jamming detection.
1 – open jamming detection.
<report_mode>
Jamming report mode
0 – neither URC nor GPIO.
1 – URC report.
2 – GPIO report. <GPIO_num> is required.
3 – both URC and GPIO. <GPIO_num> is required.
<GPIO_num>
Which GPIO is assigned to JAMMING detection. This GPIO should not be assigned to other function. Please refer to GPIO APP note to find which GPIO is not used.
< URC_percentage >
URC, indicate jamming possibility. The range of this value is [0,100]
0 – no jamming.
100 – jamming detection.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Other – interference detection.
Examples
AT+SJDR=?
+SJDR: (0,1)
OK
AT+SJDR?
+SJDR: 0,1 // jamming detection is closed.
OK
AT+SJDR?
+SJDR: 1,3,43 // jamming detection is opened and GPIO43 is assigned to jamming detection.
AT+SJDR=0
OK // JAMMING detection is closed.
AT+SJDR=1,1
OK
+SJDR: 0 // no jamming.
+SJDR: 80 // interference detection.
+SJDR: 100 // jamming detection.
AT+SJDR=1,3,43
OK
+SJDR: 0 // no jamming. GPIO43 default output low level.
+SJDR: 80 // interference detection. GPIO43 still output low level.
+SJDR: 100 // jamming detection. GPIO43 output high level.
12.19
+KEY Keypad result code
Description
URCs (Unsolicited Result Code) for keypad when keypad interface mode is active (refer to
AT +CGFUNC ). Both key press and key release generate a URC.
Refer to related HD document for more information about keypad.
SIM PIN References
NO Vendor
Syntax
Unsolicited Result Code
+KEY: <key> , [ <key_row> , <key_column> ], “ <key_text> ”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<key>
Key code in hexadecimal fomat (e.g. 0x0A).
<key_row>
Key row number.
<key_column>
Key column number.
<key_text>
The key text on EVB (Evaluation Board) for reference.
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x12
0x13
0x14
KEY VALUE REFERENCE
<key> <key_row>
0x01
0x02
0x03
0x04
0x05
2
1
1
1
4
0x06
0x07
0x08
0x09
0x0A
4
4
3
3
3
0x15
0x16
0x17
0x18
0x19
0xFF
2
2
2
1
4
3
0
1
3
4
0
0
0
<key_column>
4
3
1
2
1
2
3
1
2
3
1
2
3
0
0
4
4
4
0
4
0
2
3
0
2
1
0 row and column is same as the key pressed
Examples
(Press the menu key, and then release the key):
+KEY: 0x13, [3, 0], "MENU"
+KEY: 0xFF, [3, 0], "RELEASE"
"2"
"3"
"4"
"5"
"6"
<key_text>
"MSG"
"#"
"*"
"0"
"1"
"7"
"8"
"9"
"BACK"
"REJECT"
"UP"
"DOWN"
"CALL"
"MENU"
"SELECT"
"HANDFREE"
"NAMES"
"V+"
"V-"
"SET"
"RELEASE"
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
12.20
AT+IPREX Set local baud rate permanently
Description
This command sets the baud rate of module’s serial interface permanently, after reboot the baud rate is also valid.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+IPREX=?
Read Command
AT+IPREX?
Write Command
AT+IPREX = <speed>
Execution Command
AT+IPREX
Responses
+IPREX: (list of supported <speed> s)
OK
Responses
+IPREX: <speed>
OK
Responses
OK
ERROR
Responses
Set default value 115200:
OK
Defined values
<speed>
Baud rate per second:
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800,921600,
3200000,3686400,4000000
Examples
AT+IPREX?
+IPREX: 115200
OK
AT+IPREX=?
+IPREX: (300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400,460800,921600
3200000, 3686400, 4000000)
OK
AT+IPREX=115200
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
12.21
AT+CFGRI Indicate RI when using URC
Description
This command is used to config whether pulling down the RI pin of UART when URC reported. If
<status> is 1, host may be wake up by RI pin.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CFGRI=?
Read Command
AT+CFGRI?
Write Command
AT+CFGRI= <status
> [, <sav e> ]
Execution Command
AT+CFGRI
Responses
+CFGRI: (range of supported <status> s), (range of supported
<save> s)
OK
Responses
+CFGRI: <status> , <save>
OK
Responses
OK
ERROR
Responses
Set <status> = 1,<save> = 0:
OK
Defined values
<status>
0 off
1 on
<save>
0 <status> not saved in nonvolatile memory
1 <status> saved in nonvolatile memory.After it resets, <status> still takes effect.
Examples
AT+CFGRI=?
+CFGRI: (0-1),(0-1)
OK
AT+CFGRI?
+CFGRI: 0,0
OK
AT+CFGRI=1,1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CFGRI
OK
12.22
AT+CRIRS Reset RI pin of serial port
Description
This command is used to reset RI pin of serial port (Null modem Mode). After This command is executed, when a voice (csd, video) call or a SMS is coming or URC is reported, RI pin will be asserted. It can wake up host.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CRIRS=?
Write Command
AT+CRIRS
Syntax
Test Command
Responses
OK
Responses
OK
ERROR
Defined values
None
Examples
AT+CRIRS
OK
12.23
AT+CSUART Switch UART line mode
Description
The command is used to switch UART line mode between three and seven lines mode.
SIM PIN References
NO Vendor
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CSUART=?
Read Command
AT+CSUART?
Write Command
AT+CSUART= <mode> [, <sa ve> ]
+CSUART: (list of supported <mode> s)
OK
Responses
+CSUART: < mode >
OK
Responses
OK
ERROR
Defined values
<mode>
0 – 3 lines mode
1 – 7 lines mode
<save>
0 – don’t save the setting
1 – save the setting
Examples
AT+CSUART=1
OK
12.24
AT+CUARTWD Configure the interval time for the stable-timer
Description
This command is used to configure a delay time used while UART waken up from sleep mode.
During this delay time, any data received from UART will be ignored.
This configuration will be saved automatically. The default value is 0.
NOTE: when RX pin is used to wake up module from sleep mode, this command should be configured according to external host response time, 200ms is usually recommended. When DTR pin is used to wake up module, don’t care about this setting.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CUARTWD=?
Read Command
Responses
+CUARTWD: (0-10000)
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CUARTWD?
Write Command
AT+ CUARTWD =< interval >
+CUARTWD: < interval >
OK
Responses
OK
ERROR
Defined values
< interval >: unit: ms
0 : disable the delaytimer
Other value: interval time for the delay timer
Examples
AT+CUARTWD=0
OK
AT+ CUARTWD =200
OK
12.25
AT+CDTRISRMD Configure the trigger condition for DTR’s interrupt.
Description
This command is used to set the appropriate trigger condition for DTR’s interrupt, which will finally waking up the module.
This command is only valid for NULL modem.
The interrupt is low level triggered by default.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CDTRISRMD=?
Read Command
AT+CDTRISRMD?
Write Command
Responses
+CDTRISRMD: (list of supported <detect> s),(list of supported
< polarity >s)
OK
Responses
+CDTRISRMD: <detect> , <polarity>
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CDTRISRMD
= <detect> ,< polarity >
OK
ERROR
Defined values
<detect>
0 Level trigger
1 Edge trigger
<polarity>
0 Low trigger
1 High trigger
Examples
AT+CDTRISRMD=0,1
OK
AT+CDTRISRMD=0,0
OK
12.26
AT+CDTRISRS Enable/Disable the pin of DTR’s awakening function
Description
This command is used to enable or disable the function of waking up the module by means of
UART’s DTR pin which to trigger an interrupt
This command is only valid for NULL modem.
The function is disabled by default.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CDTRISRS=?
Read Command
AT+CDTRISRS?
Responses
+CDTRISRS: (list of supported <switch> s)
OK
Responses
+CDTRISRS: <switch>
OK
Write Command Responses
AT+CDTRISRS = <switch> OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<switch>
0 disable such function
1 enable such function
Examples
AT+CDTRISRS=1
OK
AT+CDTRISRS=0
OK
12.27
AT+CMUX Enable the multiplexer over the UART
Description
This command is used to enable the multiplexer over the UART, after enabled four virtual ports can be used as DIAG port, NMEA port, AT command port or MODEM port(configured by
+CMUXSRVPORT command) , the physical UART can no longer transfer data directly under this case.
By default all of the four virtual ports are used as AT command port.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CMUX=?
Write Command
AT+CMUX=
<value> [,< subset >[,< port
_speed >[,< N1 >[,< T1 >[,
< N2 >[,< T2 >[,< T3 >[,< k
>]]]]]]]]
Responses
+CMUX: (0)
OK
Responses
OK
ERROR
Defined values
< value >:
0 – currently only 0 is supported (basic operation mode).
< subset >:
Currently omitted
< port_speed >:
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Currently omitted, you can set speed before enable multiplexer
< N1 >:
Currently omitted
< T1 >:
Currently omitted
< N2 >:
Currently omitted
< T2 >:
Currently omitted
< T3 >:
Currently omitted
< k >:
Currently omitted
Examples
AT+CMUX=0
OK
NOTE: Currently only basic operation mode is supported .
12.28
AT+CMUXSRVPORT Configure MUX port service
Description
This command is used to configure the service for the certain MUX port; the setting is savable and will be enabled on the next startup time.
Default all of the MUX ports are configured as DATA service.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CMUXSRVPORT=?
Read Command
AT+CMUXSRVPORT?
Write Command
AT+CMUXSRVPORT=< po rt >,< service >
Responses
+CMUXSRVPORT: (0-3),(0,1,5)
OK
Responses virtual port [< port >] - < service >
OK
Responses
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
< port >
0 – MUX port, corresponding to DLCI 1 of UART multiplexor protocol.
1 – MUX port, corresponding to DLCI 2 of UART multiplexor protocol.
2 – MUX port, corresponding to DLCI 3 of UART multiplexor protocol.
3 – MUX port, corresponding to DLCI 4 of UART multiplexor protocol.
NOTE:
DLCI 0 is the control channel for MUX protocol, and DLCI 1~4 used for data communication.
M ore information about MUX protocol, please refer to 3GPP TS 27.010.
< service >
0 – DIAG Service, used for diagnostic.
1 – DATA(MODEM) Service, used for AT command control or Modem data transmit.
5 – NMEA Service, used for output GPS NMEA sentence.
Examples
AT+CMUXSRVPORT=0,1
OK
AT+CMUXSRVPORT=?
+CMUXSRVPORT: (0-3),(0,1,5)
OK
NOTE:
1. NMEA service only supported by SIM5320.
2. DIAG and NMEA service are exclusively, so it is forbidden to configure the DIAG or NMEA service to more than one MUX port.
12.29
AT+CUSBSPD Switch USB high or full speed
Description
This command is used to switch the speed of USB between high speed and full speed.
This configuration will take effect after reboot.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CUSBSPD=?
Read Command
Responses
+CUSBSPD: (list of supported <speed> s)
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CUSBSPD?
Write Command
AT+CUSBSPD
=
<speed>
+CUSBSPD: <speed>
OK
Responses
OK
ERROR
Defined values
<speed>
Integer type and nonvolatile value.
0 – High speed
1 – Full speed (default value)
Examples
AT+CUSBSPD=?
+CUSBSPD: (0-1)
OK
AT+CUSBSPD=0
OK
AT+CUSBSPD=1
OK
12.30
AT+CLEDDYNC Control the blinking frequency for the led
Description
GPIO1 of SIM52xx/SIM53xx is used to control the status led by default. Now the module supplies a new function called DYNAMIC-LED to control the led, which can control the blinking frequency dynamically, this command is just used to set the led’s ON/OFF frequency.
Note this command is valid only when the function DYNAMIC-LED is enabled. One can use
AT+CGFUNC=19, 1 to enable this function.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CLEDDYNC=?
Write Command
AT+CLEDDYNC= <on_freq
>,<off_freq>
Responses
OK
Responses
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<on_freq> led on time, unit: ms
<off_freq> led off time, unit: ms
Examples
AT+CGFUNC=19,1
OK
AT+CLEDDYNC=800,200
OK
12.31
AT+CLEDITST Adjust the sink current source
Description
This command is used to adjust the sinking current of dedicated pin CURRENT_SINK to meet design requirement. It also can be used to disable the output. The configuration will be save automatically and the default value is 10 (100mA).
NOTE: about the CURRENT_SINK pin, please refer to our hardware design documents.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CLEDITST=?
Read Command
AT+CLEDITST?
Write Command
AT+CLEDITST= < type> , <val>
Responses
+CLEDITST: (list of supported <type> s), (list of supported <val> s)
OK
Responses
+CLEDITST: <val>
OK
Responses
OK
ERROR
Defined values
< type>
0 – reserved
<val>
0 – 0mA (disable)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
1 – 10mA
2 – 20mA
3 – 30mA
4 – 40mA
5 – 50mA
6 – 60mA
7 – 70mA
8 – 80mA
9 – 90mA
10 – 100mA
11 – 110mA
12 – 120mA
13 – 130mA
14 – 140mA
15 – 150mA
Examples
AT+CLEDITST=0,0
OK
AT+CLEDITST=0,10
OK
12.32
AT+CBC Battery charge
Description
The command is used to query the current voltage of power supply.
NOTE If module is not allow the detection of battery used,then <bcs> and <bcl> may be ignored.You can get the current voltage of power supply by <vol> .
SIM PIN References
NO 3GPP TS 07.07
Syntax
Test Command
AT+CBC=?
Execution Command
AT+CBC
Responses
+CBC: (list of supported <bcs> s),(list of supported <bcl> s)
OK
Responses
+CBC: <bcs> , <bcl>,<vol> V
OK
+CME ERROR: <err>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<bcs>
0 Battery powered
<bcl>
0…100 Battery charge level
<vol>
Current voltage value (V).
Examples
AT+CBC=?
+CBC: (0),(0-100)
OK
AT+CBC
+CBC: 0,75,3.810V
OK
12.33
AT+CADC Read the value from the ADC
Description
This command is used to read the ADC value from modem. ME supports 3 types of ADC, which are raw type, temperature type and voltage type.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CADC=?
Write Command
AT+CADC= <adc>
Execution Command
AT+CADC
Responses
+CADC: (range of supported <adc> s)
OK
Responses
+CADC: <value>
OK
ERROR
Responses
Same as AT+CADC = 0:
+CADC: <value>
OK
Defined values
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<adc>
ADC type:
0
– raw type.
1
–
temperature type.
2 – voltage type(mv)
<value>
Integer type value of the ADC.
Examples
AT+CADC=?
+CADC:(0-2)
OK
AT+CADC=0
+CADC: 187
OK
12.34
AT+CADCA Read the value from the second ADC
Description
The ME supports two ADCs, and this command is used to read the voltage value from the second
ADC.
SIM PIN References
NO Vendor
Syntax
Execution Command
AT+CADCA
Responses
+CADCA: <value>
OK
Defined values
<value>
Integer type value of the voltage.
Examples
AT+CADCA
+CADCA: 1100
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
12.35
AT+CVAUXS Set state of the pin named VREG_AUX1
Description
This command is used to set state of the pin which is named VREG_AUX1.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CVAUXS=?
Read Command
AT+CVAUXS?
Write Command
AT+CVAUXS= <state>
Responses
+CVAUXS: (list of supported <state> s)
OK
Responses
+CVAUXS: <state>
OK
Responses
OK
ERROR
Defined values
<state>
0 – the pin is closed.
1 – the pin is opend(namely, open the pin)
Examples
AT+CVAUXS=1
OK
AT+CVAUXS?
+CVAUXS: 1
OK
12.36
AT+CVAUXV Set voltage value of the pin named VREG_AUX1
Description
This command is used to set the voltage value of the pin which is named VREG_AUX1.
SIM PIN References
NO Vendor
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Test Command
AT+CVAUXV=?
Read Command
AT+CVAUXV?
Write Command
AT+CVAUXV= <voltage>
Responses
+CVAUXV: (list of supported <voltage> s)
OK
Responses
+CVAUXV: <voltage>
OK
Responses
OK
ERROR
Defined values
<voltage>
Voltage value of the pin which is named VREG_AUX1. The unit is in 50*mV.
Examples
AT+CVAUXV=?
+CVAUXV:(30-61)
OK
AT+CVAUXV=40
OK
AT+CVAUXV?
+CVAUXV: 40
OK
12.37
AT+CAPWRON Auto power on setting
Description
This command is used to set the module to be powered on automatically at the appointed time.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CAPWRON=?
Read Command
Responses
+CAPWRON: (0-23), (0-59),(0-1)
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CAPWRON?
Write Command
AT+CAPWRON= <hour>,< minute>,<repeated>
+CAPWRON: <hour> , <minute>,<repeated>
OK
Responses
OK
ERROR
Defined values
<hour>
0 – 23 : the hour to power on
<minute>
0 – 59 : the minute to power on
<repeated>
0 : not repeated.
1 : repeated every day.
Examples
AT+CAPWRON=8,30,0
OK
AT+CAPWRON?
+CAPWRON: 8,30,0
OK
AT+CAPWRON=?
+CAPWRON: (0-23),(0-59),(0-1)
OK
NOTE: User can use the command AT+CAPWRON=255,255,255 to disable this function.
12.38
AT+CVALARM Low voltage Alarm
Description
This command is used to open or close the low voltage alarm function.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CVALARM=?
Responses
+CVALARM: (list of supported <enable> s), (list of supported
<voltage> s)
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+CVALARM?
Responses
+CVALARM: <enable> , <voltage>
OK
Write Command
AT+CVALARM= <enable>[,
<voltage>]
Responses
OK
ERROR
Defined values
<enable>
0 – Close
1 – Open. If voltage < <voltage> , it will report “warning! Voltage is low:<voltage value>” erery 20s.
<voltage>
Between 2800mV and 4300mV. Default value is 3450.
NOTE : The two parameters will be saved automatically.
Examples
AT+CVALARM=1,3400
OK
AT+CVALARM?
+CVALARM: 1,3400
OK
AT+CVALARM=?
+CVALARM: (0-1),(2800-4300)
OK
12.39
AT+CPMVT Set the voltage to power off the module
Description
This command is used to set the lowest working voltage and if the system voltage is lower than this value the system will power off automatically to save the module.
Also while this function is enabled the module will shutdown if the voltage is higher than
4300mV which value is hard-coded.
This function is disabled by default.
SIM PIN References
NO Vendor
Syntax
Test Command Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CPMVT=?
Read Command
AT+ CPMVT?
+CPMVT: (0,2800-4300)
OK
Responses
+ CPMVT: <voltage>
OK
Write Command Responses
AT+CPMVT = <voltage>
OK
Defined values
< voltage >
0 - disable the function
2800 - 4300 in 100mV steps.
Examples
AT+CPMVT=2800
OK
AT+CPMVT=3300
OK
12.40
AT+CAPWROFF Auto power off setting
Description
This command is used to set the module to be powered off automaticly at the appointed time.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CAPWROFF=?
Read Command
AT+CAPWROFF?
Write Command
AT+CAPWROFF= <hour>,< minute>,<repeated>
Responses
+CAPWROFF: (0-23), (0-59),(0-1)
OK
Responses
+CAPWROFF: <hour> , <minute>,<repeated>
OK
Responses
OK
ERROR
Defined values
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<hour>
0 – 23 : the hour to power off
<minute>
0 – 59 : the minute to power off
<repeated>
0 : not repeated.
1 : repeated every day.
Examples
AT+CAPWROFF=22,30,0
OK
AT+CAPWROFF?
+CAPWROFF: 22,30,0
OK
AT+CAPWROFF=?
+CAPWROFF: (0-23),(0-59),(0-1)
OK
NOTE: User can use the command AT+CAPWROFF=255,255,255 to disable this function
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
13 AT Commands for File System
The file system is used to store files in a hierarchical (tree) structure, and there are some definitions and conventions to use the Module.
Local storage space is mapped to “ C: ”.
NOTE: General rules for naming (both directories and files):
1 The length of actual fully qualified names of directories and files can not exceed 254.
2 Directory and file names can not include the following characters:
\ : * ? “ < > | , ;
3 Between directory name and file/directory name, use character “/” as list separator, so it can not appear in directory name or file name.
4 The first character of names must be a letter or a numeral or underline, and the last character can not be period “.” and oblique “/”.
13.1
AT+FSCD Select directory as current directory
Description
This command is used to select a directory. The Module supports absolute path and relative path.
Read Command will return current directory without double quotation marks.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+FSCD=?
Read Command
AT+FSCD?
Write Command
AT+FSCD= <path>
Responses
OK
Responses
+FSCD: <curr_path>
OK
Responses
+FSCD: <curr_path>
OK
ERROR
Defined values
<path>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
String without double quotes, directory for selection.
NOTE: If <path> is “..”, it will go back to previous level of directory.
<curr_path>
String without double quotes, current directory.
Examples
AT+FSCD=C:
+FSCD: C:/
OK
AT+FSCD=C:/
+FSCD: C:/
OK
AT+FSCD?
+FSCD: C:/
OK
AT+FSCD=..
+FSCD: C:/
OK
13.2
AT+FSMKDIR Make new directory in current directory
Description
This command is used to create a new directory in current directory.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+FSMKDIR=?
Write Command
AT+FSMKDIR= <dir>
Responses
OK
Responses
OK
ERROR
Defined values
<dir>
String without double quotes, directory name which does not already exist in current directory.
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+FSMKDIR= SIMTech
OK
AT+FSCD?
+FSCD: C:/
OK
AT+FSLS
+FSLS: SUBDIRECTORIES:
SIMTech
OK
13.3
AT+FSRMDIR Delete directory in current directory
Description
This command is used to delete existing directory in current directory.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+FSRMDIR=?
Write Command
AT+FSRMDIR= <dir>
Responses
OK
Responses
OK
ERROR
Defined values
<dir>
String without double quotes.
Examples
AT+FSRMDIR=SIMTech
OK
AT+FSCD?
+FSCD: C:/
OK
AT+FSLS
+FSLS: SUBDIRECTORIES:
Audio
Picture
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Video
VideoCall
OK
13.4
AT+FSLS List directories/files in current directory
Description
This command is used to list informations of directories and/or files in current directory.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+FSLS=?
Read Command
AT+FSLS?
Write Command
AT+FSLS= <type>
Execution Command
AT+FSLS
Responses
+FSLS: (list of supported <type> s)
OK
Responses
+FSLS: SUBDIRECTORIES: <dir_num> ,FILES: <file_num>
OK
Responses
[+FSLS: SUBDIRECTORIES:
<list of subdirectories>
<CR><LF>]
[+FSLS: FILES:
<list of files>
<CR><LF>]
OK
Responses
[+FSLS: SUBDIRECTORIES:
<list of subdirectories>
<CR><LF>]
[+FSLS: FILES:
<list of files>
<CR><LF>]
OK
Defined values
<dir_num>
Integer type, the number of subdirectories in current directory.
<file_num>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Integer type, the number of files in current directory.
<type>
0 – list both subdirectories and files
1 – list subdirectories only
2 – list files only
Examples
AT+FSLS?
+FSLS: SUBDIRECTORIES:2,FILES:2
OK
AT+FSLS
+FSLS: SUBDIRECTORIES:
FirstDir
SecondDir
+FSLS: FILES: image_0.jpg image_1.jpg
OK
AT+FSLS=2
+FSLS: FILES: image_0.jpg image_1.jpg
OK
13.5
AT+FSDEL Delete file in current directory
Description
This command is used to delete a file in current directory. Before do that, it needs to use AT+FSCD select the father directory as current directory.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+FSDEL=?
Write Command
AT+FSDEL= <filename>
Responses
OK
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
ERROR
Defined values
<filename>
String with or without double quotes, file name which is relative and already existing.
If <filename> is *.*, it means delete all files in current directory.
If the file path contains non-ASCII characters, the filename parameter should contain a prefix of
{non-ascii} and the quotation mark.
Examples
AT+FSDEL=image_0.jpg
OK
13.6
AT+FSRENAME Rename file in current directory
Description
This command is used to rename a file in current directory.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+FSRENAME=?
Write Command
AT+FSRENAME=
<old_name> , <new_name>
Responses
OK
Responses
OK
ERROR
Defined values
<old_name>
String with or without double quotes, file name which is existed in current directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii} and the quotation mark.
<new_name>
New name of specified file, string with or without double quotes. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii} and the quotation mark.
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+FSRENAME=image_0.jpg, image_1.jpg
OK
AT+FSRENAME= "my test.jpg", {non-ascii}"E6B58BE8AF95E99984E4BBB62E6A7067"
OK
13.7
AT+FSATTRI Request file attributes
Description
This command is used to request the attributes of file which exists in current directory.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+FSATTRI=?
Responses
OK
Write Command Responses
AT+FSATTRI= <filename> +FSATTRI: <file_size> , <create_date>
OK
Defined values
<filename>
String with or without double quotes, file name which is in current directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii} and the quotation mark.
<file_size>
The size of specified file, and the unit is in Byte.
<create_date>
Create date and time of specified file, the format is YYYY/MM/DD HH/MM/SS Week.
Week – Mon, Tue, Wed, Thu, Fri, Sat, Sun
Examples
AT+FSATTRI=image_0.jpg
+FSATTRI: 8604, 2008/04/28 10:24:46 Tue
OK
AT+FSATTRI={non-ascii}"E6B58BE8AF95E99984E4BBB62E6A7067"
+FSATTRI: 6296, 2012/01/06 00:00:00 Sun
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
13.8
AT+FSMEM Check the size of available memory
Description
This command is used to check the size of available memory. The response will list total size and used size of local storage space if present and mounted.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+FSMEM=?
Execution Command
AT+FSMEM
Responses
OK
Responses
+FSMEM: C:( <total> , <used> )
OK
Defined values
<total>
The total size of local storage space.
<used>
The used size of local storage space.
NOTE: The unit of storage space size is in Byte.
Examples
AT+FSMEM
+FSMEM: C:(11348480, 2201600)
OK
13.9
AT+FSLOCA Select storage place
Description
This command is used to set the storage place for media files.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+FSLOCA=?
Responses
+FSLOCA: (list of supported <loca> s)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+FSLOCA?
Write Command
AT+FSLOCA= <loca>
OK
Responses
+FSLOCA: <loca>
OK
Responses
OK
ERROR
Defined values
<loca>
0 – store media files to local storage space (namely “C:/”)
Examples
AT+FSLOCA=0
OK
AT+FSLOCA?
+FSLOCA: 0
OK
13.10
AT+FSCOPY Copy an appointed file
Description
This command is used to copy an appointed file on C:/ to an appointed directory on C:/ , the new file name should give in parameter.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+FSCOPY=?
Write Command
AT+FSCOPY= <file1> , <file
2> [ <sync_mode> ]
Responses
OK
Responses
+FSCOPY: <percent>
[+FSCOPY: <percent> ]
OK
OK
+FSCOPY: <percent>
[+FSCOPY: <percent> ]
+FSCOPY: END
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
If found any error:
SD CARD NOT PLUGGED IN
FILE IS EXISTING
FILE NOT EXISTING
DIRECTORY IS EXISTED
DIRECTORY NOT EXISTED
FORBID CREATE DIRECTORY UNDER \"C:/\"
FORBID DELETE DIRECTORY
INVALID PATH NAME
INVALID FILE NAME
SD CARD HAVE NO ENOUGH MEMORY
EFS HAVE NO ENOUGH MEMORY
FILE CREATE ERROR
READ FILE ERROR
WRITE FILE ERROR
ERROR
Defined values
<file1>
The sources file name or the whole path name with sources file name. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii} and the quotation mark.
<file2>
The destination file name or the whole path name with destination file name. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii} and the quotation mark.
<percent>
The percent of copy done. The range is 0.0 to 100.0
<sync_mode>
The execution mode of the command:
0 – synchronous mode
1 – asynchronous mode
NOTE:
1. The <file1> and <file2> should give the whole path and name, if only given file name, it will refer to current path (AT+FSCD) and check the file’s validity.
2. If <file2> is a whole path and name, make sure the directory exists, make sure that the file name does not exist or the file name is not the same name as the sub folder name, otherwise return error.
3. <percent> report refer to the copy file size. The big file maybe report many times, and little file report less.
4. If <sync_mode> is 1, the command will return OK immediately, and report final result with
+FSCOPY: END.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+FSCD?
+FSCD: C:/
OK
AT+FSCOPY= C:/TESTFILE,COPYFILE ( Copy file TESTFILE on C:/ to C:/COPYFILE )
+FSCOPY: 1.0
+FSCOPY: 9.7
+FSCOPY: 19.4
…
+FSCOPY: 100.0
OK
AT+FSCOPY= "my test.jpg", {non-ascii}"E6B58BE8AF95E99984E4BBB62E6A7067"
+FSCOPY:1.0
+FSCOPY:100.0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
14 AT Commands for File Transmission
The module supports file transmission between the Module and host over Xmodem protocol, and the transmission is bidirectional.
14.1
AT+CTXFILE Select file transmitted to host
Description
This command is used to select a file which will be transmitted from the module to host. After selecting the file successfully, use HyperTerminal to get the file over Xmodem protocol [refer AT
Commands Samples: File transmission to host ].
NOTE: If available memory is not enough, file transmission will fail.
If user uses HyperTerminal
Applet (MS), please make sure the storage path to host can not include Non-ASCII character, but file name can include Non-ASCII character.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CTXFILE=?
Write Command
AT+CTXFILE= <file_name>
[, <dir_type> [, <protocol> ]]
Responses
+CTXFILE: (list of supported <dir_type> s), (list of supported
<protocol> s)
OK
Responses
OK
FILE NOT EXISTING
ERROR
Defined values
<filename>
String with double quotes, file name to be transmitted to PC host which already exists. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}.
NOTE: The path name only supports ASCII character.
<dir_type>
0 – file to be transmitted is in current directory; before AT+CTXFILE execution, it needs to set current directory [refer AT+FSCD ]
NOTE: If <dir_type> is omitted, it will select a file to be transmitted which is in current directory.
AT+FSCD and AT+FSLS being used in combination can help user to check the file selected
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set whether existing or not.
<protocol>
0 – Xmodem
1 – 1K Xmodem
Examples
AT+CTXFILE=”image_0.jpg”, 0,1
OK
……
AT+FSCD=C:/
+FSCD: C:/
OK
AT+FSLS=2
+FSLS: FILES: video_2.mp4 image_1.jpg
OK
AT+CTXFILE=”video_2.mp4”
OK
….
14.2
AT+CRXFILE Set name of file received from host
Description
This command is used to set file name which is received from host to file system of module. After setting successfully, use HyperTerminal to send the file over Xmodem protocol [refer AT
Commands Samples: File received from host ].
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CRXFILE= ?
Write Command
AT+CRXFILE= <file_name>
[, <dir_type> ]
Responses
+CRXFILE: (list of supported <dir_type> s)
OK
Responses
OK
FILE IS EXISTING
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<file_name>
String with double quotes, file name which is received from host. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}.
<dir_type>
Specify storage location of file which is received from host. If this parameter is omitted, it will save the file to current directory [refer AT+FSCD ]
0 – save file received from host to current directory; before AT+CTXFILE execution, it needs to set current directory [refer AT+FSCD ]
Examples
AT+CRXFILE=”image_8.jpg”,0
OK
……
AT+FSCD=C:/
+FSCD: C:/
OK
AT+CRXFILE=”video.mp4”
OK
….
14.3
AT+CMWAIT Config the waiting seconds before xmodem start receiving
Description
This command is used to config the waiting seconds when setup a xmodem receiving task. Set to zero means no wait and start receive process. Ought to be used together with +CRXFILE command.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CMWAIT=?
Read Command
AT+CMWAIT?
Responses
+CMWAIT: (0-60)
OK
Responses
+CMWAIT: < value >
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
AT+CMWAIT=< value >
Execution Command
AT+CMWAIT
Responses
OK
ERROR
Responses
+CMWAIT: 10
OK
Defined values
< value >:
0 – 60 second
Examples
AT+FSCD=C:/Video
+FSCD: C:/Video/
OK
AT+CMWAIT=5
OK
AT+CRXFILE=”1.txt”
OK
…
NOTE:
1. The default < value > is 10 second, it can be set to any positive integer value, 0~60 is permitted..
2. The < value > cann’t be saved, will be set to default value when the device restart later.
14.4
AT+CFTRANRX Transfer a file to EFS
Description
This command is used to transfer a file to EFS.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CFTRANRX=?
Write Command
AT+CFTRANRX=“ <filepat >
Responses
+CFTRANRX: [{non-ascii}]"FILEPATH"
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set h> ”, <len> OK
>
ERROR
ERROR
Defined values
<filepath>
The path of the file on EFS.
<len>
The length of the file data to send.
NOTE
The <filepath> must be a full path with the directory path.
Examples
AT+CFTRANRX=”c:/MyDir/t1.txt”,10
>testcontent
OK
14.5
AT+CFTRANTX Transfer a file from EFS to host
Description
This command is used to transfer a file from EFS to host. Before using this command, the
AT+CATR must be used to set the correct port used.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CFTRANTX=?
Responses
+CFTRANTX: [{non-ascii}]"FILEPATH"
OK
Responses Write Command
AT+CFTRANTX=“ <filepath
> ”
[
+CFTRANTX: DATA, <len>
…
+CFTRANTX: DATA, <len>
…
]
+CFTRANTX: 0
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
ERROR
Defined values
<filepath>
The path of the file on EFS.
<len>
The length of the following file data to output.
NOTE
The <filepath> must be a full path with the directory path.
Examples
AT+CFTRANTX=”c:/MyDir/t1.txt”
+CFTRANTX: DATA, 10
Testcontent
+CFTRANTX: 0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
15 AT Commands for MMS
The maximum of
recipients, copy-to recipients, and secret recipients are respective 20. The maximum length of recipients’ number is 60
.
15.1
AT+CMMSCURL Set the URL of MMS center
Description
This command is used to set the URL of MMS center.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSCURL=?
Read Command
AT+CMMSCURL?
Write Command
AT+CMMSCURL=”< mmsc url> ”
Responses
+CMMSCURL:”URL”
OK
Responses
+CMMSCURL: “ <mmscurl> ”
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<mmscurl>
The URI of MMS center, not including http://.The max length of <mmscurl> is 40 bytes.
Examples
AT+CMMSCURL=”mmsc.monternet.com”
OK
AT+CMMSCURL?
+CMMSCURL:”mmsc.monternet.com”
OK
AT+CMMSCURL=?
+CMMSCURL:”URL”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
15.2
AT+CMMSPROTO Set the protocol parameters and MMS proxy
Description
This command is used to set the protocol parameters and MMS proxy address.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSPROTO=?
Read Command
AT+CMMSPROTO?
Write Command
AT+CMMSPROTO= <type>
[,<gateway>,<port>]
Responses
+CMMSPROTO:
(0,1),”(0-255).(0-255).(0-255).(0-255)”,(0-65535)
OK
Responses
+CMMSPROTO: <type>,<gateway>,<port>
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<type>
The application protocol for MMS:
0 – WAP
1 – HTTP
<gateway>
IP address of MMS proxy. If empty, it is set to 255.255.255.255.
<port>
Port of MMS proxy. If empty, it is set to 65535.
Examples
AT+CMMSPROTO=0,”10.0.0.172”,9201
OK
AT+CCMMSPROTO?
+CMMSPROTO: 0,”10.0.0.172”,9201
OK
AT+CMMSPROTO=?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CMMSPROTO: (0,1),”(0-255).(0-255).(0-255).(0-255)”,(0-65535)
OK
15.3
AT+CMMSSENDCFG Set the parameters for sending MMS
Description
This command is used to set the parameters for sending MMS.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSSENDCFG=?
Read Command
AT+CMMSSENDCFG?
Responses
+CMMSSENDCFG: (0-6),(0-3),(0,1),(0,1),(0-2),(0-4)
OK
Responses
+CMMSSENDCFG:
<valid>,<pri>,<sendrep>,<readrep>,<visible>,<class>
OK
Write Command
AT+CMMSSENDCFG= <val id>,<pri>,<sendrep>,<readre p>,<visible>,<class>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<valid>
The valid time of the sent MMS:
0 – 1 hour.
1 – 12 hours.
2 – 24 hour.
3 – 2 days.
4 – 1 week.
5 – maximum.
6 – Not set (default).
<pri>
Priority:
0 – lowest.
1 – normal.
2 – highest.
3 – Not set (default)
<sendrep>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Whether need delivery report:
0 – No (default).
1 – Yes.
<readrep>
Whether need read report:
0 – No (default).
1 – Yes.
<visible>
Whether to show the address of the sender:
0 – hide the address of the sender.
1 – Show the address of the sender even if it is a secret address.
2 – Not set (default).
<class>
The class of MMS:
0 – personal.
1 – advertisement.
2 – informational.
3 – auto.
4 – Not set (default).
Examples
AT+CMMSSENDCFG=6,3,1,1,2,4
OK
AT+CMMSSENDCFG?
+CMMSSENDCFG:6,3,1,1,2,4
OK
AT+CMMSSENDCFG=?
+CMMSSENDCFG: (0-6),(0-3),(0,1),(0,1),(0-2),(0-4)
OK
15.4
AT+CMMSEDIT Enter or exit edit mode
Description
This command is used to enter or exit edit mode of mms.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSEDIT=?
Responses
+CMMSEDIT: (0,1)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+CMMSEDIT?
Write Command
AT+CMMSEDIT= <mode>
OK
Responses
+CMMSEDIT: <mode>
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<mode>
Whether to allow edit MMS:
0 – No.
1 – Yes.
Examples
AT+CMMSEDIT=0
OK
AT+CMMSEDIT?
+CMMSEDIT:0
OK
AT+CMMSEDIT=?
+CMMSEDIT:(0-1)
OK
15.5
AT+CMMSDOWN Download the file data or title from UART
Description
This command is used to download file data to MMS body. When downloading a text file or title from UART, the text file or title must start with \xFF\xFE , \xFE\xFF or \xEF\xBB\xBF to indicate whether it is UCS2 little endian, UCS2 big endian or UTF-8 format. Without these OCTETS, the text file or title will be regarded as UTF-8 format.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSDOWN=?
Responses
+CMMSDOWN: “PIC”,(1<max_pdu_size> ),”NAME”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
AT+CMMSDOWN= <type>,
<size>[,<name>]
Or
AT+CMMSDOWN= <type>,
<dir>,<filename>
+CMMSDOWN: “TEXT”,(1<max_pdu_size> ),”NAME”
+CMMSDOWN: “AUDIO”,(1<max_pdu_size> ),”NAME”
+CMMSDOWN: “VIDEO”,(1<max_pdu_size> ),”NAME”
+CMMSDOWN: “SDP”,(1<max_pdu_size> )
+CMMSDOWN: “FILE”,(0),”FILENAME”
+CMMSDOWN: “TITLE”,(1-40)
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<type>
The type of file to download:
“PIC” – JPG/GIF/PNG/TIFF file.
“TEXT" – plain text file.
“AUDIO” – MIDI/WAV/AMR/MPEG file.
“VIDEO” – 3GPP/MP4 file.
“SDP” – application/sdp type
“FILE" – file in the UE.
“TITLE" – subject of the MMS.
<size>
The size of file data needs to download through AT interface.
<name>
The name of the file to download. When <type> is “TITLE” or “SDP”, this field is not needed.
Otherwise, it cannot be omitted.
<dir>
The directory of the selected file:
0 – current directory[refer to AT+FSCD ]
1 – “C:/Picture” directory
2 – “C:/Video” directory
3 – “C:/VideoCall” directory
7 – “C:/Audio” directory
<filename>
The name of the file existing in the UE to download.
<max_pdu_size>
The maximum size of MMS PDU permitted.
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CMMSDOWN=?
+CMMSDOWN: “PIC”,(1-102400),”NAME”
+CMMSDOWN: “TEXT”,(1-102400),”NAME”
+CMMSDOWN: “AUDIO”,(1-102400),”NAME”
+CMMSDOWN: “VIDEO”,(1-102400),”NAME”
+CMMSDOWN:"SDP",(1-102400)
+CMMSDOWN: “FILE”,(0),” FILENAME”
+CMMSDOWN: “TITLE”,(1-40)
OK
AT+CMMSDOWN=”PIC”,20112,”test1.jpg” <CR><LF>
>….(20112 bytes of data transferred in AT interface)
OK
AT+CMMSDOWN="FILE",2,” test2.wav”
OK
15.6
AT+CMMSDELFILE Delete a file within the editing MMS body
Description
This command is used to delete a file within the editing MMS body.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSDELFILE=?
Write Command
AT+CMMSDELFILE= <inde x>
Responses
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<index>
The index of the file to delete contains in the MMS body.
Examples
AT+CMMSDELFILE=2
OK
AT+CMMSDELFILE=?
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
15.7
AT+CMMSSEND Send MMS
Description
This command is used to send MMS. It can only be performed in edit mode of MMS.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSSEND=?
Write Command
AT+CMMSSEND= <address
>
Execute Command
Responses
+CMMSSEND=”ADDRESS”
OK
Responses
OK
+CMMSSEND:0
ERROR
+CME ERROR: <err>
Or
OK
+CMMSSEND : <err>
Responses
AT+CMMSSEND OK
+CMMSSEND:0
ERROR
+CME ERROR: <err> or
OK
+CMMSSEND : <err>
Defined values
<address>
Mobile phone number or email address.
As mobile phone number, the max length is 40;
As email address, the max length is 60;
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CMMSSEND=”13613623116”
OK
+CMMSSEND:0
AT+CMMSSEND
OK
+CMMSSEND:0
AT+CMMSSEND=” 13613623116”
OK
+CME ERROR: 190
AT+CMMSSEND=2,”13613623116”
+CME ERROR: 177
15.8
AT+CMMSRECP Add the recipients
Description
This command is used to add the recipients.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSRECP=?
Read Command
AT+CMMSRECP?
Write Command
AT+CMMSRECP= <addr>
Responses
+CMMSRECP: ”ADDRESS ”
OK
Responses
+CMMSRECP: (list of <addr> s)
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<addr>
Mobile phone number or email address.
As mobile phone number, the max length is 40;
As email address, the max length is 60;
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CMMSRECP=?
+CMMSRECP: "ADDRESS"
OK
AT+CMMSRECP?
+CMMSRECP:"[email protected]”;”15813862534”
OK
AT+CMMSRECP=”13818362596"
OK
15.9
AT+CMMSCC Add the cc recipients
Description
This command is used to add the cc recipients.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSCC=?
Read Command
AT+CMMSCC?
Write Command
AT+CMMSCC= <addr>
Responses
+CMMSCC: ”ADDRESS ”
OK
Responses
+CMMSCC: (list of <addr> s)
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<addr>
Mobile phone number or email address 。
As mobile phone number, the max length is 40;
As email address, the max length is 60;
Examples
AT+CMMSCC=?
+CMMSCC: "ADDRESS"
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CMMSCC?
+CMMSCC:"[email protected]”;”15813862534”
OK
AT+CMMSCC=”13818362596"
OK
15.10
AT+CMMSBCC Add the secret recipients
Description
This command is used to add the secret recipients.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSBCC=?
Read Command
AT+CMMSBCC?
Write Command
AT+CMMSBCC= <addr>
Responses
+CMMSBCC: ”ADDRESS ”
OK
Responses
+CMMSBCC: (list of <addr> s)
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<addr>
Mobile phone number or email address.
As mobile phone number, the max length is 40;
As email address, the max length is 60;
Examples
AT+CMMSBCC=?
+CMMSBCC: "ADDRESS"
OK
AT+CMMSBCC?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CMMSBCC:"[email protected]”;”15813862534”
OK
AT+CMMSBCC=”13818362596"
OK
15.11
AT+CMMSDELRECP Delete the recipients
Description
This command is used to delete the recipients. The execute command is used to delete all the recipients
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSDELRECP=?
Write Command
AT+CMMSDELRECP= <add r>
Execute Command
AT+CMMSDELRECP
Responses
+CMMSDELRECP: ”ADDRESS ”
OK
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<addr>
Mobile phone number or email address.
As mobile phone number, the max length is 40;
As email address, the max length is 60;
Examples
AT+CMMSDELRECP=?
+CMMSDELRECP: "ADDRESS"
OK
AT+CMMSDELRECP
OK
AT+CMMSDELRECP=”13818362596"
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
15.12
AT+CMMSDELCC Delete the cc recipients
Description
This command is used to delete the cc recipients. The execution command is used to delete all the cc recipients
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSDELCC=?
Responses
+CMMSDELCC: ”ADDRESS ”
OK
Write Command
AT+CMMSDELCC= <addr>
Responses
OK
ERROR
+CME ERROR: <err>
Execute Command
AT+CMMSDELCC
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<addr>
Mobile phone number or email address.
As mobile phone number, the max length is 40;
As email address, the max length is 60;
Examples
AT+CMMSDELCC=?
+CMMSDELCC: "ADDRESS"
OK
AT+CMMSDELCC
OK
AT+CMMSDELCC=”13818362596"
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
15.13
AT+CMMSDELBCC Delete the secret recipients
Description
This command is used to delete the secret recipients. The execution command is used to delete all the secret recipients
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSDELBCC=?
Write Command
AT+CMMSDELBCC= <addr
>
Execute Command
AT+CMMSDELBCC
Responses
+CMMSDELBCC: ”ADDRESS ”
OK
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<addr>
Mobile phone number or email address.
As mobile phone number, the max length is 40;
As email address, the max length is 60;
Examples
AT+CMMSDELBCC=?
+CMMSDELRECP: "ADDRESS"
OK
AT+CMMSDELBCC
OK
AT+CMMSDELBCC=”13818362596"
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
15.14
AT+CMMSRECV Receive MMS
Description
This command is used to receive MMS. It only can be perform in non-edit mode of MMS
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSRECV=?
Write Command
AT+CMMSRECV= <locatio n>
Responses
+CMMSRECV: ”LOCATION”
OK
Responses
OK
+CMMSRECV: 0
ERROR
+CME ERROR: <err>
OK
+CMMSRECV : <err>
Defined values
<location>
Reported by +WAP_PUSH_MMS message
Examples
AT+CMMSRECV=”http://211.136.112.84/MI76xou_anB”
OK
+CMMSRECV: 0
AT+CMMSRECV= http://211.136.112.84/MI76xou_anB”
OK
+CMMSRECV : 190
AT+CMMSRECV=”http://211.136.112.84/MI76xou_anB”
+CME ERROR: 177
15.15
AT+CMMSVIEW View the information of MMS from the inbox or the memory
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to view the information of MMS from the inbox or the memory. The title part of the MMS is formatted with UCS2 little endian character set.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSVIEW=?
Write Command
AT+CMMSVIEW= <index>
Execute Command
AT+CMMSVIEW
Responses
+CMMSVIEW: (0,1)
OK
Responses
+CMMSVIEW:<mmstype>,”<sender>”,”<receipts>”,”<ccs>”,”<bc cs>”,”<datetime>”,”<subject>”,<size><CR><LF>list of
[<fileIndex>, <name>, <type>, <filesize>]<CR><LF>
OK
ERROR
+CME ERROR: <err>
Responses
+CMMSVIEW:<mmstype>,”<sender>”,”<receipts>”,”<ccs>”,”<bc cs>”,”<datetime>”,”<subject>”,<size><CR><LF>list of
[<fileIndex>, <name>, <type>,<fileSize>]<CR><LF>
OK
ERROR
+CME ERROR: <err>
Defined values
<index>
The index of MMS.
<mmstype>
The state of MMS:
0 – Received MMS.
1 – Sent MMS.
2 – Unsent MMS.
<sender>
The address of the sender
<receipts>
The list of the recipients separated by “;”
<ccs>
The list of cc recipients separated by “;”
<bccs>
The list of secret recipients separated by “;”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<datetime>
For received MMS, it is the time indication when you received the MMS. For other MMS, it is the time indication when you create the MMS.
<subject>
The title of MMS.
<size>
The data size of MMS.
<fileIndex>
The index of each file contained in the MMS body
<name>
The name of each file contained in the MMS body
<type>
The type of each file contained in the MMS body:
1 – unknown type.
2 – text.
3 – text/html.
4 – text/plain.
5 – image.
6 – image/gif.
7 – image/jpg.
8 – image/tif.
9 – image/png.
10 – audio/midi.
11 – audio/x-wav.
12 – audio /amr.
13 – audio /mpeg.
14 – video /mp4.
15 – video /3gpp.
29 – application/sdp.
30 – application/smil.
<fileSize>
The size of each file contained in the MMS body
Examples
AT+CMMSVIEW=?
+CMMSVIEW: (0,1)
OK
AT+CMMSVIEW
+CMMSVIEW:2,"",,,,"0000-00-00 00:00:00","dsidfisids",83867
0,"1.txt",4,10
1,"80.jpg",7,83794
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CMMSVIEW=1
+CMMSVIEW:0,"",,,,"2009-03-10 10:06:12","my title",83867
0,"1.txt",4,10
1,"80.jpg",7,83794
OK
15.16
AT+CMMSREAD Read the given file of MMS in the memory
Description
This command is used to read the given file of MMS in the memory. When reading a text file, it will be converted to UCS2 little endian before final UART output.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSREAD=?
Responses
OK
Write Command
AT+CMMSREAD= <index>
Responses
+CMMSREAD: <name> , <datSize>
< FileContent >
OK
ERROR
+CME ERROR: <err>
Defined values
<index>
The index of the given file contained in the MMS body
<name>
The name of the given file contained in the MMS body
<datSize>
The size of the given file contained in the MMS body
<FileContent>
The content of the file to be read
Examples
AT+CMMSREAD=?
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CMMSREAD=3
+CMMSREAD:"1.jpg",83794
…(File Content)
OK
15.17
AT+CMMSSNATCH Snatch the given file in MMS
Description
This command is used to snatch the given file of MMS in memory, and save it to UE file system.
If the input file name already exists in the selected directory, it will fail.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSSNATCH=?
Responses
OK
Write Command
AT+CMMSSNATCH= <inde x>,<dir>,”<filename>”
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<index>
The index of the given file contained in the MMS body
<dir>
The directory of the selected file:
0 – current directory[[refer to AT+FSCD ]
<filename>
The name of the given file contained in the MMS body
Examples
AT+CMMSSNATCH=?
OK
AT+CMMSSNATCH=3,2,”mylocalfile.jpg”
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
15.18
AT+CMMSSAVE Save the MMS to a mail box
Description
This command is used to save the selected MMS into a mailbox.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSSAVE=?
Write Command
AT+CMMSSAVE= <index>[,
<mmstype>]
Execute Command
AT+CMMSSAVE
Responses
+CMMSSAVE: (0-1),(0-2)
OK
Responses
+CMMSSAVE: <index>
OK
ERROR
+CME ERROR: <err>
Responses
+CMMSSAVE: <index>
OK
ERROR
+CME ERROR: <err>
Defined values
<index>
The index of mail box is selected to save the MMS
<mmstype>
The status of MMS:
0 – Received MMS.
1 – Sent MMS.
2 – Unsent MMS.
Examples
AT+CMMSSAVE=?
+CMMSSAVE: (0-1),(0-2)
OK
AT+CMMSSAVE=1
+CMMSSAVE: 1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
15.19
AT+CMMSDELETE Delete MMS in the mail box
Description
This command is used to delete MMS in the mailbox. The execute command is used to delete all
MMS in the mailbox.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSDELETE=?
Write Command
AT+CMMSDELETE?
Write Command
AT+CMMSDELETE= <inde x>
Execute Command
AT+CMMSDELETE
Responses
+CMMSDELETE: (0-1)
OK
Responses
+CMMSDELETE: <mmsNum>
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<index>
The index of the mail box, where is selected to save the MMS.
<mmsNum>
The number of MMS saved in the mail box
Examples
AT+CMMSDELETE=?
+CMMSDELETE: (0-1)
OK
AT+CMMSDELETE
OK
AT+CMMSDELETE=1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
15.20
AT+CMMSSYSSET Configure MMS transferring parameters
Description
This command is used to configure MMS transferring setting.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSSYSSET=?
Write Command
AT+CMMSSYSSET?
Write Command
AT+CMMSSYSSET= <max_ pdu_size>[ , <wap_send_buf_ size>[ , <wap_recv_buf_size>
[ , <wap_send_buf_count>]]]
Responses
+CMMSSYSSET:
(10240<max_pdu_size> ),(512-4096),(512-4096),(1<wap_send_b uf_count> )
OK
Responses
+CMMSSYSSET:
<max_pdu_size> , <wap_send_buf_size> , <wap_recv_buf_size> , <w ap_send_buf_count>
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
< max_pdu_size >
The maximum MMS pdu size allowed by operator.
<wap_send_buf_size>
The length of WTP PDU for sending
<wap_recv_buf_size>
The length of WTP PDU for receiving
<wap_send_buf_count>
The count of buffers for WTP sending in group
Examples
AT+CMMSSYSSET=?
+CMMSSYSSET: (10240-307712),(512-4096),(512-4096),(1-8)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CMMSSYSSET?
+CMMSSYSSET:102400,1460,1500,6
OK
AT+CMMSSYSSET=102400,1430,1500,8
OK
AT+CMMSSYSSET=102400
OK
15.21
AT+CMMSINCLEN Increase the length of audio/video attachment header
Description
This command is used to increase the length of video/audio attachment header length in the length indicator field. This command is used to be compatible with some operators. This command must be set before calling AT+CMMSEDIT=1 .
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSINCLEN=?
Read Command
AT+CMMSINCLEN?
Write Command
AT+CMMSINCLEN= <mod e>
Responses
+CMMSINCLEN: (0,1)
OK
Responses
+CMMSINCLEN: <mode>
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<mode>
Whether to increase the length:
0 – No.
1 – Yes.
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CMMSINCLEN=0
OK
AT+CMMSINCLEN?
+CMMSINCLEN:0
OK
AT+CMMSINCLEN=?
+CMMSINCLEN:(0-1)
OK
15.22
AT+CMMSUA Set the User-Agent of MMS packet
Description
This command is used to set the User-Agent of MMS packet.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSUA=?
Read Command
AT+CMMSUA?
Write Command
AT+CMMSUA=“ <useragent
> ”
Responses
+CMMSUA: “UserAgent”
OK
Responses
+CMMSUA: “ <useragent> ”
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<useragent>
The User-Agent of MMS packet. The maximum length is 511 bytes.
Examples
AT+CMMSUA=“ Test my UserAgent”
OK
AT+CMMSUA?
+CMMSUA: “ Test my UserAgent”
OK
AT+CMMSUA=?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CMMSUA: “ UserAgent”
OK
15.23
AT+CMMSPROFILE Set the User-Agent profile of MMS packet
Description
This command is used to set the User-Agent profile of MMS packet.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CMMSPROFILE=?
Read Command
AT+CMMSPROFILE?
Write Command
AT+CMMSPROFILE=” <pr ofile> ”
Responses
+CMMSPROFILE:”UserAgentProfile”
OK
Responses
+CMMSPROFILE: “ <profile> ”
OK
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<profile>
The User-Agent profile of MMS packet. The maximum length is 511 bytes.
Examples
AT+CMMSPROFILE=” Test my UserAgent profile”
OK
AT+CMMSPROFILE?
+CMMSUA:” Test my UserAgent profile”
OK
AT+CMMSPROFILE=?
+CMMSPROFILE:”UserAgent profile”
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
15.24
Supported Unsolicited Result Codes in MMS
Description
This section lists all the unsolicited result code in MMS module.
15.24.1 Indication of Sending/Receiving MMS
MMS Sending
+CMMSSEND: <err>
MMS Notification
+WAP_PUSH_MMS: <sende r> , <transaction_id> , <locatio n> , <timestamp> , <class> , <si ze>
MMS Receiving
+CMMSRECV: <err>
Description
This indication means the result of sending MMS. If successful, it reports +CMMSSEND:0, or else, it report +CMMSSEND: <err>
Description
This indication means there is a new MMS received in the MMS center.
Description
This indication means the result of receiving MMS. If successful, it reports +CMMSRECV:0, or else, it reports +CMMSRECV: <err>
Defined values
< sender>
The sender address of the received MMS
<transaction_id>
The X-Mms-Transaction-ID of the received MMS
<location>
The X-Mms-Content-Location of the received MMS
<timestamp>
The timestamp of the WAP push message
<class>
The X-Mms-Class of the received MMS
0 – Expired
1 – Retrieved
2 – Rejected
3 – Deferred
4 – Unrecognized
<size>
The size of the received MMS
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+WAP_PUSH_MMS
+WAP_PUSH_MMS: "15001844675","RROpJGJVyjeA","http://211.136.112.84/RROpJGJVyjeA"
,"09/03/17,17:14:41+32",0,13338
15.24.2 Summary of CME ERROR Codes for MMS
Code of <err> Description
201 Unknown error for mms
171 MMS task is busy now
184
185
186
187
188
189
190
191
179
180
181
182
183
172
173
174
175
176
177
178
The mms data is over size
The operation is over time
There is no mms receiver
The storage for address is full
Not find the address
Invalid parameter
Failed to read mms
There is not a mms push message (reserved)
Memory error
Invalid file format
The mms storage is full
The box is empty
Failed to save mms
Busy editing mms now
Not allowed to edit now
No content in the buffer
Failed to receive mms
Invalid mms pdu
Network error
Failed to read file in UE
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16 AT Commands for Internet Service
16.1
Common
16.1.1
AT+CGSOCKCONT Define socket PDP context
Description
This command specifies socket PDP context parameter values for a PDP context identified by the
(local) context identification parameter <cid> . The number of PDP contexts that may be in a defined state at the same time is given by the range returned by the test command. A special form of the write command (AT+CGSOCKCONT=<cid>) causes the values for context <cid> to become undefined.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CGSOCKCONT=?
Read Command
AT+CGSOCKCONT?
Responses
+CGSOCKCONT: (range of supported <cid> s), <PDP_type> ,,,(list of supported <d_comp> s),(list of supported <h_comp> s)
OK
ERROR
Responses
+CGSOCKCONT: [ <cid> , <PDP_type> , <APN> , <PDP_addr> ,
<d_comp> , <h_comp> [<CR><LF>
+CGSOCKCONT: <cid> , <PDP_type> , <APN> , <PDP_addr> ,
<d_comp> , <h_comp> [...]]]
OK
ERROR
Responses
OK
Write Command
AT+CGSOCKCONT=
<cid> [, <PDP_type>
[, <APN> [, <PDP_addr>
[, <d_comp> [, <h_comp> ]]]]]
Execution Command
AT+CGSOCKCONT
ERROR
Responses
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<cid>
(PDP Context Identifier) a numeric parameter which specifies a particular PDP context definition.
The parameter is local to the TE-MT interface and is used in other PDP context-related commands.
The range of permitted values (minimum value = 1) is returned by the test form of the command.
1…16
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6(reserved)
<APN>
(Access Point Name) a string parameter which is a logical name that is used to select the GGSN or the external packet data network.
<PDP_addr>
A string parameter that identifies the MT in the address space applicable to the PDP.
Read command will continue to return the null string even if an address has been allocated during the PDP startup procedure.
<d_comp>
A numeric parameter that controls PDP data compression:
0 – off (default if value is omitted)
1 – on
<h_comp>
A numeric parameter that controls PDP header compression:
0 – off (default if value is omitted)
1 – on
Examples
AT+CGSOCKCONT?
+CGSOCKDCONT: 1,"IP","","0.0.0.0",0,0
OK
AT+CGSOCKCONT=?
+CGSOCKCONT: (1-16),"IP",,,(0,1),(0,1)
+CGSOCKCONT: (1-16),"PPP",,,(0,1),(0,1)
+CGSOCKCONT: (1-16),"IPV6",,,(0,1),(0,1)
OK
16.1.2
AT+CSOCKSETPN Set active PDP context’s profile number
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command sets default active PDP context’s profile number. When we activate PDP by using
AT+NETOPEN command, we need use the default profile number, and the context of this profile is set by AT+CGSOCKCONT command.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSOCKSETPN=?
Read Command
AT+CSOCKSETPN?
Write Command
AT+CSOCKSETPN=
<profile_number>
Execution Command
AT+CSOCKSETPN
Responses
+CSOCKSETPN: (list of supported <profile_number> s)
OK
ERROR
Responses
+CSOCKSETPN: <profile_number>
OK
ERROR
Responses
OK
ERROR
Responses
OK
ERROR
Defined values
<profile_number>
A numeric parameter that identifies default profile number, the range of permitted values is one to sixteen.
1…16
Examples
AT+CSOCKSETPN=1
OK
16.1.3
AT+CSOCKAUTH Set type of authentication for PDP-IP connections of socket
Description
This command is used to set type of authentication for PDP-IP connections of socket.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSOCKAUTH=?
Read Command
AT+CSOCKAUTH?
Write Command
AT+CSOCKAUTH= <cid>
[, <auth_type> [, <passwd> [, < user> ]]]
Execution Command
AT+CSOCKAUTH
Responses
+CSOCKAUTH:(range of supported <cid> s),(list of supported
<auth _type> s), <passwd_len> , <user_len>
OK
ERROR
+CME ERROR: <err>
Responses
+CSOCKAUTH: <cid> , <auth_type> [, <user>] <CR><LF>
+CSOCKAUTH: <cid> , <auth_type> [, <user> ]<CR><LF>
…
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
ERROR
+CME ERROR: <err>
Defined values
<cid>
Parameter specifies a particular PDP context definition. This is also used in other PDP context-related commands.
1…16
<auth_type>
Indicate the type of authentication to be used for the specified context. If CHAP is selected another parameter <passwd> needs to be specified. If PAP option is selected, two additional parameters, <passwd> and <user>, need to be specified.
0 – none
1 – PAP
2 – CHAP
3 – PAP or CHAP
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<passwd>
Parameter specifies the password used for authentication.
<user>
Parameter specifies the user name used for authentication.
<passwd_len>
The maximum length of the password.
<user_len>
The maximum length of the user name.
Examples
AT+CSOCKAUTH=?
+CSOCKAUTH: (1-16),(0-3),132,132
OK
AT+CSOCKAUTH=1,2,”SIMCOM”,”123”
OK
16.1.4
AT+CGSOCKQREQ Quality of service profile (requested)
Description
This command allows the TE to specify a Quality of Service Profile that is used when the MT sends an Activate PDP Context Request message to the network. A special form of the set command
( AT+CGSOCKQREQ = <cid>) causes the requested profile for context number <cid> to become undefined.
This command only affects the embedded socket related PDP context definition (refer to
AT+CGSOCKCONT ).
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CGSOCKQREQ=?
Read Command
Responses
+CGSOCKQREQ: <PDP_type> , (list of supported <precedence> s),
(list of supported <delay> s), (list of supported <reliability> s) , (list of supported <peak> s), (list of supported <mean> s) [<CR><LF>
+CGSOCKQREQ: <PDP_type> , (list of supported <precedence> s),
(list of supported <delay> s), (list of supported <reliability> s) , (list of supported <peak> s), (list of supported <mean> s)
[…]]
OK
ERROR
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CGSOCKQREQ? +CGSOCKQREQ: [ <cid> , <precedence > , <delay> , <reliability> ,
<peak> , <mean> [<CR><LF>
+CGSOCKQREQ: <cid> , <precedence > , <delay> , <reliability.> ,
<peak> , <mean> […]]]
OK
ERROR
Write Command
AT+CGSOCKQREQ= <cid>
[, <precedence>
[, <delay> [, <reliability>
[, <peak> [, <mean> ]]]]]
Execution Command
AT+CGSOCKQREQ
Responses
OK
ERROR
Responses
OK
ERROR
Defined values
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command). The range is from 1 to 16.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6(reserved)
<precedence>
A numeric parameter which specifies the precedence class:
0 – network subscribed value
1 – high priority
2 – normal priority
3 – low priority
<delay>
A numeric parameter which specifies the delay class:
0 – network subscribed value
1 – delay class 1
2 – delay class 2
3 – delay class 3
4 – delay class 4
<reliability>
A numeric parameter which specifies the reliability class:
0 – network subscribed value
1 – Non real-time traffic,error-sensitive application that cannot cope with data loss
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss
3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/-
SM,and SMS
4 – Real-time traffic,error-sensitive application that can cope with data loss
5 – Real-time traffic error non-sensitive application that can cope with data loss
<peak>
A numeric parameter which specifies the peak throughput class:
0 – network subscribed value
1 – Up to 1000 (8 kbit/s)
2 – Up to 2000 (16 kbit/s)
3 – Up to 4000 (32 kbit/s)
4 – Up to 8000 (64 kbit/s)
5 – Up to 16000 (128 kbit/s)
6 – Up to 32000 (256 kbit/s)
7 – Up to 64000 (512 kbit/s)
8 – Up to 128000 (1024 kbit/s)
9 – Up to 256000 (2048 kbit/s)
<mean>
A numeric parameter which specifies the mean throughput class:
0 – network subscribed value
1 – 100 (~0.22 bit/s)
2 – 200 (~0.44 bit/s)
3 – 500 (~1.11 bit/s)
4 – 1000 (~2.2 bit/s)
5 – 2000 (~4.4 bit/s)
6 – 5000 (~11.1 bit/s)
7 – 10000 (~22 bit/s)
8 – 20000 (~44 bit/s)
9 – 50000 (~111 bit/s)
10 – 100000 (~0.22 kbit/s)
11 – 200000 (~0.44 kbit/s)
12 – 500000 (~1.11 kbit/s)
13 – 1000000 (~2.2 kbit/s)
14 – 2000000 (~4.4 kbit/s)
15 – 5000000 (~11.1 kbit/s)
16 – 10000000 (~22 kbit/s)
17 – 20000000 (~44 kbit/s)
18 – 50000000 (~111 kbit/s)
31 – optimization
Examples
AT+CGSOCKQREQ?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CGSOCKQREQ:
OK
AT+CGSOCKQREQ=?
+CGSOCKQREQ: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGSOCKQREQ: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGSOCKQREQ: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
OK
16.1.5
AT+CGSOCKEQREQ 3G quality of service profile (requested)
Description
The test command returns values supported as a compound value.
The read command returns the current settings for each defined context for which a QOS was explicitly specified.
The write command allows the TE to specify a Quality of Service Profile for the context identified by the context identification parameter <cid> which is used when the MT sends an Activate PDP
Context Request message to the network.
A special form of the write command, AT+CGSOCKEQREQ = <cid> causes the requested profile for context number <cid> to become undefined.
This command only affects the embedded socket related PDP context definition (refer to
AT+CGSOCKCONT ).
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CGSOCKEQREQ=?
Responses
+CGSOCKEQREQ: <PDP_type> ,(list of supported <Traffic class> s),(list of supported <Maximum bitrate UL> s),(list of supported <Maxim um bitrate DL> s),(list of supported
<Guaranteed bitrate UL> s,(list of supported <Guaranteed bitrate
DL> s),(list of supported <Deliv ery order> s),(list of supported
<Maximum SDU size> s),(list of supported <SDU error ratio> s),(list of supported <Residual bit error
Ratio> s),(list of supported <Delivery of erroneous SDUs> s),(list of
Supported <Transfer delay> s),(list of supported <Traffic handling priority> s) [<CR><LF>
+CGSOCKEQREQ: <PDP_type> ,(list of supported <Traffic class> s),(list of supported <Maximum bitrate UL> s),(list of supported <Maxim um bitrate DL> s),(list of supported
<Guaranteed bitrate UL> s,(list of supported <Guaranteed bitrate
DL> s),(list of supported <Deliv ery order> s),(list of supported
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<Maximum SDU size> s),(list of supported <SDU error ratio> s),(list of supported <Residual bit error
Ratio> s),(list of supported <Delivery of erroneous SDUs> s),(list of
Supported <Transfer delay> s),(list of supported <Traffic handling priority> s) […]]
OK
Read Command
AT+CGSOCKEQREQ?
Responses
+CGSOCKEQREQ: [ <cid> , <Traffic class> , <Maximum bitrate
UL> , <Ma ximum bitrate DL> , <Guaranteed bitrate
UL> , <Guaranteed bitrate DL> , <Delivery order> , <Maximum SDU size> , <SDU error ratio> ,
<Residual bit error ratio> , <Delivery of erroneous SDUs> , <Transfer
Delay> , <Traffic handling priority> ][<CR><LF>
+CGSOCKEQREQ: <cid> , <Traffic class> , <Maximum bitrate
UL> , <Ma ximum bitrate DL> , <Guaranteed bitrate
UL> , <Guaranteed bitrate DL> , <Delivery order> , <Maximum SDU size> , <SDU error ratio> ,
<Residual bit error ratio> , <Delivery of erroneous SDUs> , <Transfer
Delay> , <Traffic handling priority> […]]
OK
Write Command
AT+CGSOCKEQREQ= <cid
> [, <Traffic class> [, <Maxim um bitrate UL >[, <Maximu m bitrate DL >[, <Guarantee d bitrateUL >[, <Guaranteed bitrate DL >[, <Delivery ord er> [, <Maximum SDU size>
[, <SDU error ratio> [, <Residual bit error ratio> [, <Delivery of e rroneous SDUs> [, <Transfer delay> [, <Traffic handling p riority> ]]]]]]]]]]]]
Execution Command
AT+CGSOCKEQREQ
Responses
OK
ERROR
+CME ERROR: <err>
Responses
OK
Defined values
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<cid>
Parameter specifies a particular PDP context definition.The parameter is also used in other PDP context-related commands. The range is from 1 to 16.
<Traffic class>
0 – conversational
1 – streaming
2 – interactive
3 – background
4 – subscribed value
<Maximum bitrate UL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g.
AT+CGSOCKEQREQ =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Maximum bitrate DL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g.
AT+CGSOCKEQREQ =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Guaranteed bitrate UL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.
AT+CGSOCKEQREQ =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Guaranteed bitrate DL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.
AT+CGSOCKEQREQ =…,32,…).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Delivery order>
This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.
0 – no
1 – yes
2 – subscribed value
<Maximum SDU size>
This parameter indicates the maximum allowed SDU size in octets.
The range is from 0 to 1520. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<SDU error ratio>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10
-3 would be specified as “5E3”(e.g.AT+CGSOCKEQREQ=..,”5E3”,…).
“0E0” – subscribed value
“1E2”
“7E3”
“1E3”
“1E4”
“1E5”
“1E6”
“1E1”
<Residual bit error ratio>
This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered
SDUs.As an example a target residual bit error ratio of 5*10
-3
would be specified as “5E3”(e.g.
AT+CGSOCKEQREQ=…,”5E3”,..).
“0E0” – subscribed value
“5E2”
“1E2”
“5E3”
“4E3”
“1E3”
“1E4”
“1E5”
“1E6”
“6E8”
<Delivery of erroneous SDUs>
This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
0 – no
1 – yes
2 – no detect
3 – subscribed value
<Transfer delay>
This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP in milliseconds.
The range is from 0 to 4000. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Traffic handling priority>
This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS
Bearer compared to the SDUs of the other bearers.
The range is from 0 to 3. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<PDP_type>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6(reserved)
Examples
AT+CGSOCKEQREQ?
+CGSOCKEQREQ:
OK
AT+CGSOCKEQREQ =?
+CGSOCKEQREQ: "IP",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E1"
,"1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4"
,"1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
+CGSOCKEQREQ: "PPP",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E1
","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4
","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
+CGSOCKEQREQ: "IPV6",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E
1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E
4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
OK
16.1.6
AT+CGSOCKQMIN Quality of service profile (minimum acceptable)
Description
This command allows the TE to specify a minimum acceptable profile which is checked by the MT against the negotiated profile returned in the Activate PDP Context Accept message.A special form of the set command, AT+CGSOCKQMIN = <cid> causes the minimum acceptable profile for context number <cid> to become undefined.
This command only affects the embedded socket related PDP context definition (refer to
AT+CGSOCKCONT ).
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CGSOCKQMIN=?
Responses
+CGSOCKQMIN: <PDP_type> , (list of supported <precedence> s),
(list of supported <delay> s), (list of supported <reliability> s) , (list of supported <peak> s), (list of supported <mean> s) [<CR><LF>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+CGSOCKQMIN?
Write Command
AT+CGSOCKQMIN=
<cid> [, <precedence>
[, <delay> [, <reliability>
[, <peak> [, <mean> ]]]]]
Execution Command
AT+CGSOCKQMIN
+CGSOCKQMIN: <PDP_type> , (list of supported <precedence> s),
(list of supported <delay> s), (list of supported <reliability> s) , (list of supported <peak> s), (list of supported <mean> s)[…]]
OK
ERROR
Responses
+CGSOCKQMIN: [ <cid> , <precedence > , <delay> , <reliability> ,
<peak> , <mean> [<CR><LF>
+CGSOCKQMIN: <cid> , <precedence > , <delay> , <reliability.> ,
<peak> , <mean>
[…]]]
OK
ERROR
Responses
OK
ERROR
Responses
OK
Defined values
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT+CGDCONT command). The range is from 1 to 16.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6(reserved)
<precedence>
A numeric parameter which specifies the precedence class:
0 – network subscribed value
1 – high priority
2 – normal priority
3 – low priority
<delay>
A numeric parameter which specifies the delay class:
0 – network subscribed value
1 – delay class 1
2 – delay class 2
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3 – delay class 3
4 – delay class 4
<reliability>
A numeric parameter which specifies the reliability class:
0 – network subscribed value
1 – Non real-time traffic,error-sensitive application that cannot cope with data loss
2 – Non real-time traffic,error-sensitive application that can cope with infrequent data loss
3 – Non real-time traffic,error-sensitive application that can cope with data loss, GMM/-
SM,and SMS
4 – Real-time traffic,error-sensitive application that can cope with data loss
5 – Real-time traffic error non-sensitive application that can cope with data loss
<peak>
A numeric parameter which specifies the peak throughput class:
0 – network subscribed value
1 – Up to 1000 (8 kbit/s)
2 – Up to 2000 (16 kbit/s)
3 – Up to 4000 (32 kbit/s)
4 – Up to 8000 (64 kbit/s)
5 – Up to 16000 (128 kbit/s)
6 – Up to 32000 (256 kbit/s)
7 – Up to 64000 (512 kbit/s)
8 – Up to 128000 (1024 kbit/s)
9 – Up to 256000 (2048 kbit/s)
<mean>
A numeric parameter which specifies the mean throughput class:
0 – network subscribed value
1 – 100 (~0.22 bit/s)
2 – 200 (~0.44 bit/s)
3 – 500 (~1.11 bit/s)
4 – 1000 (~2.2 bit/s)
5 – 2000 (~4.4 bit/s)
6 – 5000 (~11.1 bit/s)
7 – 10000 (~22 bit/s)
8 – 20000 (~44 bit/s)
9 – 50000 (~111 bit/s)
10 – 100000 (~0.22 kbit/s)
11 – 200000 (~0.44 kbit/s)
12 – 500000 (~1.11 kbit/s)
13 – 1000000 (~2.2 kbit/s)
14 – 2000000 (~4.4 kbit/s)
15 – 5000000 (~11.1 kbit/s)
16 – 10000000 (~22 kbit/s)
17 – 20000000 (~44 kbit/s)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
18 – 50000000 (~111 kbit/s)
31 – optimization
Examples
AT+CGSOCKQMIN?
+CGSOCKQMIN:
OK
AT+CGSOCKQMIN=?
+CGSOCKQMIN: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGSOCKQMIN: "PPP",(0-3),(0-4),(0-5),(0-9),(0-18,31)
+CGSOCKQMIN: "IPV6",(0-3),(0-4),(0-5),(0-9),(0-18,31)
OK
16.1.7
AT+CGSOCKEQMIN 3G quality of service profile (minimum acceptable)
Description
The test command returns values supported as a compound value.
The read command returns the current settings for each defined context for which a QOS was explicitly specified.
The write command allow the TE to specify a Quallity of Service Profile for the context identified by the context identification parameter <cid> which is checked by the MT against the negotiated profile returned in the Activate/Modify PDP Context Accept message.
A special form of the write command, AT+CGSOCKEQMIN = <cid> causes the requested for context number <cid> to become undefined.
This command only affects the embedded socket related PDP context definition (refer to
AT+CGSOCKCONT ).
SIM PIN References
YES Vendor
Syntax
Test Command Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CGSOCKEQMIN=?
Read Command
AT+CGSOCKEQMIN?
+CGSOCKEQMIN: <PDP_type> ,(list of supported <Traffic class> s),(list of supported <Maximum bitrate UL> s),(list of supported <Maxim um bitrate DL> s),(list of supported
<Guaranteed bitrate UL> s,(list of supported <Guaranteed bitrate
DL> s),(list of supported <Deliv ery order> s),(list of supported
<Maximum SDU size> s),(list of supported <SDU error ratio> s),(list of supported <Residual bit error
Ratio> s),(list of supported <Delivery of erroneous SDUs> s),(list of
Supported <Transfer delay> s),(list of supported <Traffic handling priority> s) [<CR><LF>
+CGSOCKEQMIN: <PDP_type> ,(list of supported <Traffic class> s),(list of supported <Maximum bitrate UL> s),(list of supported <Maxim um bitrate DL> s),(list of supported
<Guaranteed bitrate UL> s,(list of supported <Guaranteed bitrate
DL> s),(list of supported <Deliv ery order> s),(list of supported
<Maximum SDU size> s),(list of supported <SDU error ratio> s),(list of supported <Residual bit error
Ratio> s),(list of supported <Delivery of erroneous SDUs> s),(list of
Supported <Transfer delay> s),(list of supported <Traffic handling priority> s) […]]
OK
Responses
+CGSOCKEQMIN: [ <cid> , <Traffic class> , <Maximum bitrate
UL> , <Ma ximum bitrate DL> , <Guaranteed bitrate
UL> , <Guaranteed bitrate DL> , <Delivery order> , <Maximum SDU size> , <SDU error ratio> ,
<Residual bit error ratio> , <Delivery of erroneous SDUs> , <Transfer
Delay> , <Traffic handling priority> ][<CR><LF>
+CGSOCKEQMIN: <cid> , <Traffic class> , <Maximum bitrate
UL> , <Ma ximum bitrate DL> , <Guaranteed bitrate
UL> , <Guaranteed bitrate DL> , <Delivery order> , <Maximum SDU size> , <SDU error ratio> ,
<Residual bit error ratio> , <Delivery of erroneous SDUs> , <Transfer
Delay> , <Traffic handling priority> […]]
OK
Write Command
AT+CGSOCKEQMIN= <cid
> [, <Traffic class> [, <Maxim um bitrate UL >[, <Maximu m bitrate DL >[, <Guarantee
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set d bitrateUL >[, <Guaranteed bitrate DL >[, <Delivery ord er> [, <Maximum SDU size>
[, <SDU error ratio> [, <Residual bit error ratio> [, <Delivery of e rroneous SDUs> [, <Transfer delay> [, <Traffic handling p riority> ]]]]]]]]]]]]
Execution Command
AT+CGSOCKEQMIN
ERROR
+CME ERROR: <err>
Responses
OK
Defined values
<cid>
Parameter specifies a particular PDP context definition.The parameter is also used in other PDP context-related commands. The range is from 1 to 16.
<Traffic class>
0 – conversational
1 – streaming
2 – interactive
3 – background
4 – subscribed value
<Maximum bitrate UL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(up-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g.
AT+CGSOCKEQMIN =…,32,…). (refer TS 24.008 [8] subclause 10.5.6.5).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Maximum bitrate DL>
This parameter indicates the maximum number of kbits/s delivered to UMTS(down-link traffic)at a
SAP.As an example a bitrate of 32kbit/s would be specified as 32(e.g.
AT+CGSOCKEQMIN =…,32,…). (refer TS 24.008 [8] subclause 10.5.6.5).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Guaranteed bitrate UL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(up-link traffic)at a
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.
AT+CGSOCKEQMIN =…,32,…). (refer TS 24.008 [8] subclause 10.5.6.5).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Guaranteed bitrate DL>
This parameter indicates the guaranteed number of kbit/s delivered to UMTS(down-link traffic)at a
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SAP(provided that there is data to deliver).As an example a bitrate of 32kbit/s would be specified as
32(e.g.
AT+CGSOCKEQMIN =…,32,…). (refer to TS 24.008 [8] subclause 10.5.6.5).
The range is from 0 to 8460. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Delivery order>
This parameter indicates whether the UMTS bearer shall provide in-sequence SDU delivery or not.
0 – no
1 – yes
2 – subscribed value
<Maximum SDU size>
This parameter indicates the maximum allowed SDU size inoctets. (refer to TS 24.008 [8] subclause 10.5.6.5).
The range is from 0 to 1520. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<SDU error ratio>
This parameter indicates the target value for the fraction of SDUs lost or detected as erroneous.SDU error ratio is defined only for conforming traffic.As an example a target SDU error ratio of 5*10
-3 would be specified as “5E3”(e.g.
AT+CGSOCKEQMIN =..,”5E3”,…).
“0E0” – subscribed value
“1E2”
“7E3”
“1E3”
“1E4”
“1E5”
“1E6”
“1E1”
<Residual bit error ratio>
This parameter indicates the target value for the undetected bit error ratio in the delivered SDUs. If no error detection is requested,Residual bit error ratio indicates the bit error ratio in the delivered
SDUs.As an example a target residual bit error ratio of 5*10
-3
would be specified as “5E3”(e.g.
AT+ CGSOCKEQMIN =…,”5E3”,..).
“0E0” – subscribed value
“5E2”
“1E2”
“5E3”
“4E3”
“1E3”
“1E4”
“1E5”
“1E6”
“6E8”
<Delivery of erroneous SDUs>
This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0 – no
1 – yes
2 – no detect
3 – subscribed value
<Transfer delay>
This parameter indicates the targeted time between request to transfer an SDU at one SAP to its delivery at the other SAP,in milliseconds. (refer TS 24.008 [8] subclause 10.5.6.5).
The range is from 0 to 4000. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<Traffic handling priority>
This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS
Bearer compared to the SDUs of the other bearers.
The range is from 0 to 3. The default value is 0. If the parameter is set to '0' the subscribed value will be requested.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6(reserved)
Examples
AT+CGSOCKEQMIN?
+ CGSOCKEQMIN:
OK
AT+CGSOCKEQMIN =?
+CGSOCKEQMIN: "IP",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E1"
,"1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4"
,"1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
+CGSOCKEQMIN: "PPP",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E1
","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4
","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
+CGSOCKEQMIN: "IPV6",(0-4),(0-384),(0-384),(0-384),(0-384),(0-2),(0-1520),("0E0","1E
1","1E2","7E3","1E3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E
4","1E5","1E6","6E8"),(0-3),(0,100-4000),(0-3)
OK
16.1.8
AT+CENDUPPDP Duplicate PDP activation
Description
This command is used to enable or disable duplicate PDPs activation with the same APN.
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
NO Vendor
Syntax
Test Command
AT+CENDUPPDP=?
Read Command
AT+CENDUPPDP?
Write Command
AT+CENDUPPDP=
<DUP_PDP_Enable>
Responses
+CENDUPPDP: (list of supported <DUP_PDP_Enable> s)
OK
Responses
+CENDUPPDP: <DUP_PDP_Enable>
OK
Responses
OK
ERROR
Defined values
< DUP_PDP_Enable> a numeric parameter which sets whether enable duplicate PDPs activation with the same APN.
0 disable
1 enable
Examples
AT+CENDUPPDP=?
+CENDUPPDP: (0,1)
OK
AT+CENDUPPDP=1
OK
16.1.9
AT+CIPDNSSET Set DNS query parameters
Description
This command is used to set DNS query parameters. The timeout value for performing DNS query is <net_open_time> + 3000ms + 1000ms*<dns_query_retry_counter>. Here <net_open_time> is the time for opening PS network. <dns_query_retry_counter> is the retry counter for sending DNS query using UDP packet.
SIM PIN References
NO Vendor
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Test Command
AT+CIPDNSSET=?
Read Command
AT+CIPDNSSET?
Write Command
AT+CIPDNSSET=[ <ma x_net_retries> ][,
[ <net_timeout> ][,
[ <max_query_retries> ]]]
Responses
OK
Responses
+CIPDNSSET:
<max_query_retries>
OK
<max_net_retries> ,
Responses
OK
ERROR
<net_timeout> ,
Defined values
<max_net_retries>
Maxmimum retry times for opening PS network to perform DNS query. The range is from 0 to 3.
Default value is 3.
<net_timeout>
Timeout value for each opening PS network operation when performing DNS query. The range is from 3000ms to 120000ms. Default value is 30000ms.
<max_query_retries>
Maximum retry times for performing DNS query using UDP packet. The range is from 0 to 7.
Default value is 7.
Examples
AT+CIPDNSSET?
+CIPDNSSET: 1,30000,3
OK
AT+CIPDNSSET=1,30000,1
OK
16.1.10
AT+CDNSGIP Query the IP address of given domain name
Description
This command is used to query the IP address of given domain name.
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
YES Vendor
Syntax
Test Command
AT+CDNSGIP=?
Write Command
AT+CDNSGIP= <domain name>
Responses
OK
Responses
If successful,return:
+CDNSGIP: 1, <domain name> , <IP address>
OK
If fail,return:
+CDNSGIP: 0, <dns error code>
ERROR
ERROR
Defined values
<domain name>
A string parameter (string should be included in quotation marks) which indicates the do ma-in name.
<IP address>
A string parameter (string should be included in quotation marks) which indicates the IP address corresponding to the domain name.
<dns error code>
A numeric parameter which indicates the error code.
10 DNS GENERAL ERROR
Examples
AT+CDNSGIP=?
OK
AT+CDNSGIP=”www.google.com”
+CDNSGIP: 1,"www.google.com","203.208.39.99"
OK
16.1.11
AT+CDNSGHNAME Query the domain name of given IP address
Description
This command is used to query the domain name of given IP address.
SIM PIN References
YES Vendor
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Test Command
AT+CDNSGHNAME=?
Write Command
AT+CDNSGHNAME= <IP address>
Responses
OK
Responses
If successful,return:
+CDNSGHNAME: <index> , <domain name> , <IP address>
OK
If fail,return:
+CDNSGHNAME: 0, <dns error code>
ERROR
ERROR
Defined values
<domain name>
A string parameter (string should be included in quotation marks) which indicates the do ma-in name.
<IP address>
A string parameter (string should be included in quotation marks) which indicates the IP address corresponding to the domain name.
<dns error code>
A numeric parameter which indicates the error code.
10 DNS GENERAL ERROR
<index>
A numeric parameter which indicates DNS result index. This value is always 1 if performing successfully. Currently only the first record returned from the DNS server will be reported.
Examples
AT+CDNSGHNAME=?
OK
AT+CDNSGHNAME=” 58.32.231.148”
+CDNSGHNAME: 1,"mail.sim.com","58.32.231.148"
OK
16.1.12
AT+CPING Ping destination address
Description
This command is used to ping destination address.
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
YES Vendor
Syntax
Test Command
AT+CPING=?
Write Command
AT+CPING= <dest_addr>,<dest_ad dr_type>
[,<num_pings>[,<data_packet_size
>[,<interval_time>[,<wait_time>
[,<TTL>]]]]]
Responses
+CPING:IP address, (list of supported
< dest_addr_type > s) , (1-100), (4-188),
(1000-10000),(10000-100000), (16-255)
OK
Responses
OK
If ping’s result_type = 1
+CPING:
<result_type>,<resolved_ip_addr>,<data_packet_size>,<rtt>,
<TTL>
If ping’s result_type = 2
+CPING: <result_type>
If ping’s result_type = 3
+CPING:
<result_type>,<num_pkts_sent>,<num_pkts_recvd>,<num_p kts_lost>,<min_rtt>,<max_rtt>,<avg_rtt>
ERROR
Defined values
< dest_addr >
The destination is to be pinged; it can be an IP address or a domain name.
<dest_addr_type>
Integer type. Address family type of the destination address
1 – IPv4.
2 – IPv6(reserved)
<num_pings>
Integer type. The num_pings specifies the number of times the ping request (1-100) is to be sent.
The default value is 4.
<data_packet_size>
Integer type. Data byte size of the ping packet (4-188). The default value is 64 bytes.
<interval_time>
Integer type. Interval between each ping. Value is specified in milliseconds (1000ms-10000ms). The default value is 2000ms.
<wait_time>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Integer type. Wait time for ping response. An ping response received after the timeout shall not be processed. Value specified in milliseconds (10000ms-100000ms). The default value is 10000ms.
<TTL>
Integer type. TTL(Time-To-Live) value for the IP packet over which the ping(ICMP ECHO
Request message) is sent (16-255), the default value is 255.
<result_type>
1 – Ping success
2 – Ping time out
3 – Ping result
<num_pkts_sent>
Indicates the number of ping requests that were sent out.
<num_pkts_recvd>
Indicates the number of ping responses that were received.
<num_pkts_lost>
Indicates the number of ping requests for which no response was received.
<min_rtt>
Indicates the minimum Round Trip Time(RTT).
<max_rtt>
Indicates the maximum RTT.
<avg_rtt>
Indicates the average RTT.
<resolved_ip_addr>
Indicates the resolved ip address.
< rtt>
Round Trip Time.
Examples
AT+CPING=?
+CPING:IP address,(1,2), (1-100), (4-188),(1000-10000),(10000-100000), (16-255)
OK
AT+CPING="www.baidu.com",1,4,64,1000,10000,255
OK
+CPING: 1,119.75.217.56,64,410,255
+CPING: 1,119.75.217.56,64,347,255
+CPING: 1,119.75.217.56,64,346,255
+CPING: 1,119.75.217.56,64,444,255
+CPING: 3,4,4,0,346,444,386
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.1.13
AT+CPINGSTOP Stop an ongoing ping session
Description
This command is used to stop an ongoing ping session.
SIM PIN References
YES Vendor
Syntax
Write Command
AT+CPINGSTOP
Test Command
AT+CPINGSTOP=?
Defined values
<result_type>
1 – Ping success
2 – Ping time out
3 – Ping result
<num_pkts_sent>
Indicates the number of ping requests that were sent out.
<num_pkts_recvd>
Indicates the number of ping responses that were received.
<num_pkts_lost>
Indicates the number of ping requests for which no response was received.
<resolved_ip_addr>
Indicates the resolved ip address.
<min_rtt>
Indicates the minimum Round Trip Time (RTT).
<max_rtt>
Indicates the maximum RTT.
<avg_rtt>
Indicates the average RTT.
Examples
Responses
+CPING:
<result_type>,<num_pkts_sent>,<num_pkts_recvd>,<num_p kts_lost>,<min_rtt>,<max_rtt>,<avg_rtt>
OK
OK
ERROR
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CPINGSTOP
OK
16.1.14
AT+CTCPFIN Configure TCP FIN
Description
This command is used to configure whether the module should wait for TCP_FIN in
TCP_FINWAIT2 state.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CTCPFIN=?
Read Command
AT+CTCPFIN?
Write Command
AT+CTCPFIN=
<TCP_FIN_Enable> ,
<DelayTm>
Responses
+CTCPFIN: (list of supported <TCP_FIN_Enable> s),(list of supported <DelayTm> s)
OK
Responses
+CTCPFIN: <TCP_FIN_Enable> , <DelayTm>
OK
Responses
OK
ERROR
Defined values
< TCP_FIN_Enable > a numeric parameter which sets whether waiting for TCP_FIN inTCP_FINWAIT2 state.
0 not waiting
1 waiting
<DelayTm> a numeric parameter which is number of seconds to delay before closing the PS network. This parameter only affects the AT+NETCLOSE command when using single TCP/UDP mode. The range is 0 to 10.
Examples
AT+CTCPFIN=?
+CTCPFIN: (0,1),(0-10)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CTCPFIN=1,2
OK
16.1.15
AT+CTCPKA Conigure TCP heartbeat
Description
This command is used to set TCP heartbeat parameters..
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CTCPKA=?
Read Command
AT+CTCPKA?
Write Command
AT+CTCPKA=
<TCP_KA_Enable> , <KeepI dleTm> , <KeepAliveMaxTry
>
Responses
+CTCPKA: (list of supported <TCP_KA_Enable> s),(list of supported <KeepIdleTm> s) ,(list of supported
<KeepAliveMaxTry> s)
OK
Responses
+CTCPKA: <TCP_KA_Enable> , <KeepIdleTm> , <KeepAliveMaxT ry>
OK
Responses
OK
ERROR
Defined values
< TCP_KA_Enable > a numeric parameter which sets whether enable TCP heartbeat function or not.
0 disable
1 enable
<KeepIdleTm> a numeric parameter which is number of minutes to delay after last time of sending TCP data. The range is 1 to 120.
<KeepAliveMaxTry>
Maximum times for sending Keep-Alive checking. The range is 1 to 10.
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CTCPKA=?
+CTCPKA: (0,1),(1-120) ,(1-10)
OK
AT+CTCPKA=1,3,3
OK
16.1.16
AT+CTEUTP Set unknown incoming TCP packet echo
Description
This command is used to enable or disable unknown incoming TCP packet echo.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CTEUTP=?
Read Command
AT+CTEUTP?
Write Command
AT+CTEUTP =
<Echo_Unknown_TCP_Ena ble>
Responses
+CTEUTP: (list of supported <Echo_Unknown_TCP_Enable> s)
OK
Responses
+CTEUTP: <Echo_Unknown_TCP_Enable>
OK
Responses
OK
ERROR
Defined values
<Echo_Unknown_TCP_Enable> a numeric parameter which sets whether enable or disable unknown incoming TCP packet echo option.
0 disable
1 enable
Examples
AT+CTEUTP=?
+CTEUTP: (0,1)
OK
AT+CTEUTP=1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
16.1.17
AT+CUPURE Set UDP port unreachable ICMP echo
Description
This command is used to enable or disable UDP port unreachable echo.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CUPURE=?
Read Command
AT+CUPURE?
Write Command
AT+CUPURE=
<UDP_PORT_UNREACHA
BLE_Enable>
Responses
+CUPURE: (list of supported
<UDP_PORT_UNREACHABLE_Enable> s)
OK
Responses
+CUPURE: < UDP_PORT_UNREACHABLE_Enable>
OK
Responses
OK
ERROR
Defined values
<UDP_PORT_UNREACHABLE_Enable> a numeric parameter which sets whether enable or disable UDP port unreachable ICMP echo option.
0 disable
1 enable
Examples
AT+CUPURE=?
+CUPURE: (0,1)
OK
AT+CUPURE=1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.1.18
AT+CINICMPALLOW Preferred ICMP filter
Description
This command is used to filter the incoming ICMP packets that are not allowed.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CINICMPALLOW=?
Responses
+ CINICMPALLOW: (list of supported <mode> s)
OK
Read Command
AT+CINICMPALLOW?
Write Command
AT+CINICMPALLOW= <m ode>
Responses
+CINICMPALLOW: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
64bit number, the value is “1” << “ <pos> ” , then or by bit.
<pos>
Flag value from 0 to 63.
Value:
0 ICMP ECHO REPLY
3 ICMP DESTINATION UNREACH
5 ICMP REDIRECT
11 TIME-TO-ALIVE EXCEEDED
13 ICMP TIMESTAMP
14 ICMP TIME REPLY
16 INFORMATION REPLY
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CINICMPALLOW=0xFFFFFFFFFFFFFEFF
OK
AT+CINICMPALLOW?
+CINICMPALLOW: 0xFFFFFFFFFFFFFEFF
OK
16.2
TCP/UDP
16.2.1
AT+CIPCCFG Configure parameters of socket
Description
This command is used to configure parameters of socket. For the write command, the parameter part cannot be empty.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CIPCCFG=?
Read Command
AT+CIPCCFG?
Write Command
AT+CIPCCFG=
[<NmRetry>][,[<DelayTm>]
[,[ < Ack>][,[<errMode>][,]<
HeaderType>][,[[<AsyncMo de>][,[<TimeoutVal>]]]]]]]]
Responses
+CIPCCFG: (list of supported <NmRetry> s),(list of supported
<DelayTm> s) , (list of supported <Ack> s),(list of supported
<errMode> s),(list of supported <HeaderType> s), (list of supported
<AsyncMode> s), (list of supported <TimeoutVal> s)
OK
Responses
+CIPCCFG: <NmRetry> , <DelayTm> , <Ack> , <errMode>,<Header-
Type>,<AsyncMode>,<TimeoutVal>
OK
Responses
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Execution Command
AT+CIPCCFG
Responses
Set default value:
OK
Defined values
< NmRetry> a numeric parameter which is number of retransmission to be made for an IP packet.The default value is 10.
<DelayTm> a numeric parameter which is number of milliseconds to delay to output data of Receiving.The default value is 0.
<Ack> a numeric parameter which sets whether reporting a string “Send ok” when sending some data as a tcp connection.
0 not reporting
1 reporting
NOTE: This parameter is only used to be compatible with old TCP/IP command set.
<errMode> a numeric parameter which sets mode of reporting error result code.
0 error result code with numeric values
1 error result code with string values
< HeaderType > a numeric parameter that select which data header of receiving data, it only takes effect in multi-client mode.
0 add data header, the format is “ +IPD<data length> ”
1 add data header, the format is “ +RECEIVE,<link num>,<data length> ”
< AsyncMode > a numeric parameter which sets mode of executing command AT+NETOPEN, AT+NETCLOSE,
AT+CIPOPEN, AT+CIPCLOSE in multi-client mode.
0 synchronous command executing
1 asynchronous command executing, ok/error return first, then report +IP OK or +IP
ERROR.
NOTE: This parameter is only used to be compatible with old TCP/IP command set.
< TimeoutVal > a numeric parameter that set the minimum retransmission timeout value for TCP connection. The unit is millisecond. The range is 500-120000.
Examples
AT+CIPCCFG=?
+CIPCCFG: (0-10),(0-1000),(0-1),(0-1),(0-1) ,(0-1) ,(500-120000)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CIPCCFG=3,500,1,1,1,0,500
OK
16.2.2
AT+CIPTIMEOUT Set TCP/IP timeout value
Description
This command is used to set timeout value for AT+NETOPEN/AT+CIPOPEN/AT+CIPSEND.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CIPTIMEOUT=?
Read Command
AT+CIPTIMEOUT?
Write Command
AT+CIPTIMEOUT=[ <n etopen_timeout>][ ,
[ <cipopen_timeout>][ ,
[ <cipsend_timeout>]]]
Responses
OK
Responses
+CIPTIMEOUT: <netopen_timeout> , <cipopen_timeout> ,
<cipsend_timeout>
OK
Responses
OK
ERROR
Defined values
<netopen_timeout>
Timeout value for AT+NETOPEN, default value is 120000 milliseconds.The range of this value is from 3000ms to 120000ms.
<cipopen_timeout>
Timeout value for AT+CIPOPEN, default value is 120000 milliseconds. The range of this value is from 3000ms to 120000ms.
<cipsend_timeout>
Timeout value for AT+CIPSEND, default value is 120000 milliseconds. The range of this value is from 3000ms to 120000ms.
Examples
AT+CIPTIMEOUT?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CIPTIMEOUT: 30000,20000,40000
OK
AT+CIPTIMEOUT=30000,20000,40000
OK
16.2.3
AT+CIPSENDMODE Select sending mode
Description
This command is used to sending wait peer TCP ACK mode or sending without waiting peer TCP
ACK mode. The default mode is sending without waiting peer TCP ACK mode.
NOTE: Currently SIMCom 3G modules support both new TCP/IP command set and old TCP/IP command set, the new TCP/IP command set support multiple TCP connections, and backward compatible with the old command set. When the AT+NETOPEN command called with parameters(like AT+NETOPEN=”TCP”) according to the old command set, the sending mode configured by this command will be ignore, and the TCP data sending will wait for TCP ACK always.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CIPSENDMODE=?
Read Command
AT+CIPSENDMODE?
Responses
+CIPSENDMODE: (list of supported <mode> s)
OK
Responses
+CIPSENDMODE: <mode>
OK
Write Command
AT+CIPSENDMODE= < mode>
Responses
OK
ERROR
Defined values
<mode>
0 – sending without waiting peer TCP ACK mode
1 – sending wait peer TCP ACK mode
Examples
AT+CIPSENDMODE?
+CIPSENDMODE: 1
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CIPSENDMODE=1
OK
AT+CIPSENDMODE=?
+CIPSENDMODE: (0,1)
OK
16.2.4
AT+CIPHEAD Add an IP head when receiving data
Description
This command is used to add an IP head when receiving data.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CIPHEAD=?
Read Command
AT+CIPHEAD?
Write Command
AT+CIPHEAD= <mode>
Execution Command
AT+CIPHEAD
Responses
+CIPHEAD: (list of supported <mode> s)
OK
Responses
+CIPHEAD: <mode>
OK
Responses
OK
ERROR
Responses
Set default value:
OK
Defined values
<mode> a numeric parameter which indicates whether adding an IP header to received data or not
0 – not add IP header
1 – add IP header, the format is “ +IPD(data length) ”
Examples
AT+CIPHEAD=?
+CIPHEAD: (0-1)
OK
AT+CIPHEAD=0
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
16.2.5
AT+CIPSRIP Show Remote IP address and Port
Description
This command is used to set whether display IP address and port of sender when receiving data.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CIPSRIP=?
Read Command
AT+CIPSRIP?
Write Command
AT+CIPSRIP= <mode>
Execution Command
AT+CIPSRIP
Responses
+CIPSRIP: (list of supported <mode> s)
OK
Responses
+CIPSRIP: <mode>
OK
Responses
OK
ERROR
Responses
Set default value:
OK
Defined values
< mode> a numeric parameter which indicates whether show the prompt of where the data received or not before received data.
0 – do not show the prompt
1 – show the prompt,the format is as follows:
“RECV FROM: <IP ADDRESS> : <PORT> ”
Examples
AT+CIPSRIP=?
+CIPSRIP: (0-1)
OK
AT+CIPSRIP=1
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.2.6
AT+CIPMODE Select TCP/IP application mode
Description
This command is used to select transparent mode (data mode) or non-transparent mode (command mode ).The default mode is non-transparent mode.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CIPMODE=?
Read Command
AT+CIPMODE?
Write Command
AT+CIPMODE= <mode>
Execution Command
AT+CIPMODE
Responses
+CIPMODE: (list of supported <mode> s)
OK
Responses
+CIPMODE: <mode>
OK
Responses
OK
ERROR
Responses
Set default value ( <mode> =0 ) :
OK
Defined values
<mode>
0 – Non transparent mode
1 – Transparent mode
Examples
AT+CIPMODE?
+CIPMODE: 1
OK
AT+CIPMODE=1
OK
AT+CIPMODE=?
+CIPMODE: (0-1)
OK
AT+CIPMODE
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.2.7
AT+NETOPEN Open socket
Description
This command opens packet network,
NOTE: The test command and the write command of AT+NETOPEN is reserved for being compatible with old TCP/IP command set, and the old TCP/IP command set is not recommended to be used any longer.
SIM PIN References
YES Vendor
Syntax
Read Command
AT+NETOPEN?
Execution Command
AT+NETOPEN
Defined values
<net_state> a numeric parameter that indicates the state of PDP context activation:
0 network close (deactivated)
1 network open(activated)
<mode> a numeric parameter that module is used which mode.At present, it supports three mode,such as single-client, tcp-server and multi-client.if <mode> is 1,then <sock_type> and <port> are ignored.
0 single-client or tcp-server, this is only used to be compatible with old TCP command set
1 multi-client
<err >
The result of operation, 0 is success, other value is failure.
Examples
Responses
+NETOPEN: <net_state> , <mode>
OK
ERROR
+CME ERROR: <err>
Responses
OK
+NETOPEN: <err>
+NETOPEN: <err>
OK
+NETOPEN: <err>
ERROR
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+NETOPEN
OK
+NETOPEN: 0
AT+NETOPEN?
+NETOPEN: 1, 1
OK
16.2.8
AT+NETDORM Set/Query network dormancy state
Description
This command is used to set or query the network dormancy state.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+NETDORM=?
Read Command
AT+NETDORM?
Write Command
AT+NETDORM= <op>
Responses
+NETDORM: (list of supported <op> s)
OK
Responses
+NETDORM: <dss_state> [, <dormancy_state> ]
OK
Responses
OK
ERROR
Defined values
<op> a numeric parameter which indicates network dormancy operation
0 – Let the network leave dormancy state
1 – Let the network enter dormancy state
<dss_state>
Reserved value for some old products. Not used now.
<dormancy_state> a numeric parameter which indicates network dormancy state. Usually 0x1 or 0x4.
0x0 – Invalid state
0x1 – link down state
0x2 – link coming up state
0x4 – link up state
0x8 – link going down state
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0x10 – link resuming state
0x20 – link going null state
0x40 – link null state
Examples
AT+NETDORM=?
+NETDORM: (0-1)
OK
AT+NETDORM=1
OK
16.2.9
AT+NETCLOSE Close socket
Description
This command closes network. Before calling this command, all opened sockets must be closed first.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+NETCLOSE=?
Execution Command
AT+NETCLOSE
Responses
OK
Responses
OK
+NETCLOSE: <err>
+NETCLOSE: <err>
OK
+NETCLOSE: <err>
ERROR
ERROR
Defined values
<err>
The result of operation, 0 is success, other value is failure.
Examples
AT+NETCLOSE
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+NETCLOSE: 0
16.2.10
AT+IPADDR Inquire socket PDP address
Description
This command inquires the IP address of current active socket PDP.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+IPADDR=?
Execution Command
AT+IPADDR
Responses
OK
Responses
+IPADDR: < ip_address>
OK
+IP ERROR: <err_info>
ERROR
ERROR
Defined values
<ip_address>
A string parameter that identifies the IP address of current active socket PDP.
<err_info>
A string parameter that displays the cause of occurring error.
Examples
AT+IPADDR
+IPADDR: 10.71.155.118
OK
16.2.11
AT+SERVERSTART Startup TCP server
Description
This command starts up TCP server, and the server can receive the request of TCP client. After the command executes successfully, an unsolicited result code is returned when a client tries to connect with module and module accepts request. The unsolicited result code is +CLIENT: < link_num
> , <server_index> , <client_IP> : <port> .
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
YES Vendor
Syntax
Test Command
AT+SERVERSTART=?
Read Command
AT+SERVERSTART?
Responses
OK
+SERVERSTART: (list of supported <port> ), (list of supported < server_index > )
OK
ERROR
Responses
[+SERVERSTART: <server_index>,< port >
…]
OK
Write Command
AT+SERVERSTART= <port
>,<server_index> [, <backlog
> ]
+CIPERROR: <err>
ERROR
Responses
OK
+CIPERROR: <err>
ERROR
Defined values
<server_index>
The TCP server index.
<backlog>
The maximum connections can be queued in listen queue. The range is from 1 to 3. Default is 3.
<err>
The result of operation, 0 is success, other value is failure.
Examples
AT+SERVERSTART?
+SERVERSTART: 0, 1000
+SERVERSTART: 2, 2000
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.2.12
AT+SERVERSTOP Stop TCP server
Description
This command stops TCP server. Before stopping a TCP server, all sockets with <server_index> equals to the closing TCP server index must be closed first.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SERVERSTOP =?
Responses
OK
ERROR
Execution Command
AT+SERVERSTOP= <server
_index>
Responses
+SERVERSTOP: <server_index> , <err>
OK
OK
+SERVERSTOP: <server_index> , <err>
+SERVERSTOP: <server_index> , <err>
ERROR
ERROR
Defined values
<server_index>
The TCP server index.
<err>
The result of operation, 0 is success, other value is failure.
Examples
AT+SERVERSTOP=?
OK
AT+SERVERSTOP=0
+SERVERSTOP: 0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.2.13
AT+CIPOPEN Establish connection in multi-socket mode
Description
This command is used to establish a connection with TCP server and UDP server, The sum of all of connections is 10 。
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CIPOPEN=?
Responses
+CIPOPEN: (list of supported <link_num> s), (list of supported
<type> s)
OK
ERROR
Read Command
AT+CIPOPEN?
Responses
+CIPOPEN: <link_num> [, <type> , <serverIP> , <serverPort>,<index> ]
+CIPOPEN: <link_num> [, <type> , <serverIP>,<serverPort>,<index> ]
[…]
OK
ERROR
Write Command
AT+CIPOPEN=
<link_num> , ”TCP” , <serve rIP> , <serverPort> [, <localP ort> ]
AT+CIPOPEN=
<link_num> alPort>
, ”UDP” , , , <loc
Responses
OK
+CIPOPEN: <link_num> , <err>
Open connection successfully in transparent mode:
CONNECT <text>
Open connection failed in transparent mode:
CONNECT FAIL
+CIPOPEN: <link_num> , <err>
ERROR
ERROR
+CIPOPEN: <link_num> , <err>
OK ( if udp open )
+CIPOPEN: <link_num> , <err>
ERROR
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<link_num> a numeric parameter that identifies a connection. The range of permitted values is 0 to 9. If
AT+CIPMODE=1 is set, the <link_num> is restricted to be only 0.
<type> a string parameter that identifies the type of transmission protocol.
TCP Transfer Control Protocol
UDP User Datagram Protocol
<serverIP>
A string parameter that identifies the IP address of server.The IP address format consists of 4 octets,separated by decimal point:”AAA.BBB.CCC.DDD”. Also the domain name is supported here. If the domain name is input here, the timeout value for the AT+CIPOPEN shall be decided by
AT+CIPTIMEOUT and AT+CIPDNSSET.
<serverPort> a numeric parameter that identifies the port of TCP server, the range of permitted values is 0 to
65535.
NOTE: When open port as TCP, the port must be the opened TCP port;
When open port as UDP, the port may be any port.
But, for Qualcomm, connecting the port 0 is as an invalid operation.
<localPort> a numeric parameter that identifies the port of local socket, the range of permitted values is 0 to
65535.
<index> a numeric parameter that identifies the server index that the client linked when as a TCP server.
-1 Not as a TCP server
0-3 TCP server index
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
The result of operation, 0 is success, other value is failure.
Examples
AT+CIPOPEN=0,”TCP”,”116.228.221.51”,100
OK
+CIPOPEN: 0,0
AT+CIPOPEN=1,”UDP”,,,8080
+CIPOPEN: 0,0
OK
AT+CIPOPEN=?
+CIPOPEN: (0-9), (“TCP”, “UDP”)
OK
AT+CIPOPEN?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CIPOPEN: 0, “TCP”, “116.228.221.51”, 100, -1
+CIPOPEN: 1
+CIPOPEN: 2
+CIPOPEN: 3
+CIPOPEN: 4
+CIPOPEN: 5
+CIPOPEN: 6
+CIPOPEN: 7
+CIPOPEN: 8
+CIPOPEN: 9
OK
16.2.14
AT+CIPSEND Send data through TCP or UDP connection
Description
This command is used to send data to remote side. The <length> field can be empty, when it is empty, Each <Ctrl+Z> character present in the data should be coded as <ETX><Ctrl+Z>. Each
<ESC> character present in the data should be coded as <ETX><ESC>. Each <ETX> character will be coded as <ETX><ETX>. Single <Ctrl+Z> means end of the input data. Single <ESC> is used to cancel the sending.
<ETX> is 0x03, and <Ctrl+Z> is 0x1A, <ESC> is 0x1B.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CIPSEND=?
Read Command
AT+CIPSEND?
Responses
+CIPSEND: (list of supported <link_num> s), (list of supported < length > s)
OK
+CIPERROR: <err>
ERROR
ERROR
Responses
OK
ERROR
Write Command
AT+CIPSEND= <link_num> ,
[ <length>[,<psh_val>]] <CR
> data for send
Responses
OK
+CIPSEND: <link_num> , <reqSendLength> , <cnfSendLength>
+CIPERROR: <err>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
(If the <length> field is
ERROR empty, the <ctrl+z> needs to
ERROR be entered after all data is input. <ESC> is use to cancel the sending.)
(This format is for TCP connect)
AT+CIPSEND= <link_num> ,
[ <length>],<serverIP> , <serv
If sending successfully(udp sending):
OK erPort> <CR> data for send +CIPSEND: <link_num> , <reqSendLength> , <cnfSendLength>
(If the <length> field is
+CIPERROR: <err> empty, the <ctrl+z> needs to
ERROR be entered after all data is input. <ESC> is use to
ERROR cancel the sending.)
(This format is for UDP connect)
Defined values
<link_num> a numeric parameter that identifies a connection. The range of permitted values is 0 to 9.
<length> a numeric parameter which indicates the length of sending data, it must be between1 and 1500.
<serverIP>
A string parameter that identifies the IP address of server.The IP address format consists of 4 octets,separated by decimal point:”AAA.BBB.CCC.DDD”.
<serverPort> a numeric parameter that identifies the port of TCP server, the range of permitted values is 0 to
65535.
NOTE: When open port as TCP, the port must be the opened TCP port;
When open port as UDP, the port may be any port.
But, for Qualcomm, connecting the port 0 is as an invalid operation.
< reqSendLength > a numeric parameter that requested number of data bytes to be transmitted.
< cnfSendLength > a numeric parameter that confirmed number of data bytes to be transmitted.
-1 the connection is disconnected.
0 own send buffer or other side’s congestion window are full.
Note: If the <cnfSendLength> is not equal to the <reqSendLength>, the socket then cannot be used
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set further.
<psh_val>
The psh value in TCP header.
<err_info>
A string parameter that displays the cause of occurring error.
Examples
AT+CIPSEND=0,1
> S
OK
+CIPSEND: 0, 1, 1
AT+CIPSEND=1,1,”116.236.221.75”,6775
> S
OK
+CIPSEND: 1, 1, 1
AT+CIPSEND=2,
>Hello<Ctrl+Z>
OK
+CIPSEND: 2,5,5
AT+CIPSEND=3,,”116.236.221.75”,6775
>Hello World<Ctrl+Z>
OK
+CIPSEND: 2,11,11
AT+CIPSEND=2,
>Hello<ESC>
ERROR
AT+CIPSEND=?
+CIPSEND: (0-9), (1-1500)
OK
16.2.15
AT+CIPRXGET Get the network data manually
Description
This command is used to get the network data manually.
SIM PIN References
YES Vendor
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Test Command
AT+CIPRXGET=?
Read Command
AT+CIPRXGET?
Execution Command
1.
If single-client
(AT+CIPRXGET=0):
AT+CIPRXGET=<mode>[,
<len>]
2.
If multi-client
(AT+CIPRXGET=1):
AT+CIPRXGET=<mode>,< cid>[,<len>]
Responses
1. If single-client:
+CIPRXGET: (0-4), (1-1500)
OK
2. If multi-client:
+CIPRXGET: (0-4),(0-9),(1-1500)
OK
ERROR
Responses
<mode>
OK
Responses
1. If <mode> = 0 or 1:
OK
2. If <mode> = 2 or 3:
a. If single-client:
+CIPRXGET: <mode>,<read_len>,<rest_len>
<data>
OK b. If multi-client:
+CIPRXGET: <mode>,<cid>,<read_len>,<rest_len>
<data>
OK
3. If<mode> = 4: a. If single-client:
+CIPRXGET: 4,<rest_len>
OK b. If multi-client:
+CIPRXGET: 4,<cid>,<rest_len>
OK
If ERROR occurred
+IP ERROR: <error message>
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<mode>
0 – set the way to get the network data automatically
1 – set the way to get the network data manually
2 – read data, the max read length is 1500
3 – read data in HEX form, the max read length is 750
4 – get the rest data length
<cid>
A numeric parameter that identifies a connection. The range of permitted values is 0 to 9.
<len>
The data length to be read.
Not required, the default value is 1500 when <mode>=2, and 750 when <mode>=3.
<read_len>
The length of the data that have read.
<rest_len>
The data length which not read in the buffer.
< data >
The read data.
<error message>
The list of all error message:
Invalid parameter
Operation not supported
No data
NOTE:
1.
When <mode> is set to 1 and the 2-4 mode will take effect.
2.
If AT+CIPRXGET=1, it will report +CIPRXGET: 1(single client) or
+CIPRXGET: 1,<cid>(multi client) when received data and the buffer is empty.
Examples
AT+CIPRXGET=?
+CIPRXGET: (0-4),(1-1500)
OK
AT+CIPRXGET?
+CIPRXGET: 1
OK
AT+CIPRXGET=1
OK
AT+CIPRXGET=2,100
+CIPRXGET: 2,100,1300
01234567890123456789012345678901234567890123456789012345678901234567890123456789
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
01234567890123456789
OK
AT+CIPRXGET=3,100
+CIPRXGET: 3,100,1200
30313233343536373839303132333435363738393031323334353637383930313233343536373839
30313233343536373839303132333435363738393031323334353637383930313233343536373839
3031323334353637383930313233343536373839
OK
AT+CIPRXGET=4
+CIPRXGET: 4,1200
OK
AT+CIPRXGET=2,0,100
+CIPRXGET: 2,0,100,1300
01234567890123456789012345678901234567890123456789012345678901234567890123456789
01234567890123456789
OK
AT+CIPRXGET=3,0,100
+CIPRXGET: 3,0,100,1200
30313233343536373839303132333435363738393031323334353637383930313233343536373839
30313233343536373839303132333435363738393031323334353637383930313233343536373839
3031323334353637383930313233343536373839
OK
AT+CIPRXGET=4,0
+CIPRXGET: 4,0,1200
OK
16.2.16
AT+CIPCLOSE Close TCP or UDP socket
Description
This command is used to close TCP or UDP socket.
SIM PIN References
YES Vendor
Syntax
Test Command Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CIPCLOSE=? +CIPCLOSE: (list of supported <link_num> s)
OK
Read Command
AT+CIPCLOSE?
Write Command
AT+CIPCLOSE=
<link_num>
Responses
+CIPCLOSE: <link0_state> , <link1_state> , <link2_state> ,
<link3_state> , <link4_state> , <link5_state> , <link6_state> ,
<link7_state> , <link8_state> , <link9_state>
OK
+CIPCLOSE: <link_num> , <err>
ERROR
ERROR
Responses
OK
+CIPCLOSE: <link_num> , <err>
+CIPCLOSE: <link_num> , <err>
OK
+CIPCLOSE: <link_num> , <err>
ERROR
ERROR
Defined values
<link_num> a numeric parameter that identifies a connection. The range of permitted values is 0 to 9.
<linkx_state> a numeric parameter that identifies state of <link_num> . the range of permitted values is 0 to 1.
0 disconnected
1 connected
<err_info>
A string parameter that displays the cause of occurring error.
Examples
AT+CIPCLOSE?
+CIPCLOSE: 1, 0, 0, 0, 0, 0, 0, 0, 0, 0
OK
AT+CIPCLOSE=?
+CIPCLOSE: (0-9)
OK
AT+CIPCLOSE=0
OK
+CIPCLOSE: 0,0
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.2.17
AT+CIPSTAT Inquire the total size of data sent or received
Description
This command is used to inquire the total size of data sent or received for a socket in multiple socket modes (Only valid for client TCP socket mode).
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CIPSTAT=?
Write Command
AT+CIPSTAT= <link_num>
Responses
+CIPSTAT: (list of supported <link_num> s)
OK
Responses
+CIPSTAT: <sent_size> , <recv_size>
OK
+IP ERROR: <err_info>
ERROR
Defined values
< link_num> a numeric parameter that identifies a connection. The range of permitted values is 0 to 9.
<sent_size>
Total size of sent data.
<recv_size>
Total size of received data.
<err_info>
A string parameter that displays the cause of occurring error.
Examples
AT+CIPSTAT=0
+CIPSTAT: 10, 20
OK
AT+CIPSTAT=?
+CIPSTAT: (0-9)
OK
16.2.18
AT+CIPENPSH Set PSH flag
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to set the PSH flag which accomplishes two things:
1. The sending application informs TCP that data should be sent immediately.
2. The PSH flag in the TCP header informs the receiving host that the data should be pushed up to the receiving application immediately
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CIPENPSH=?
Read Command
AT+CIPENPSH?
Responses
+CIPENPSH: (0,1)
OK
Responses
+CIPENPSH: <PSH>
OK
Write Command
AT+CIPENPSH= <PSH>
Responses
OK
ERROR
Defined values
<PSH>
The value of PSH flag. The valid value is 0 or 1.
Examples
AT+CIPENPSH=?
+CIPENPSH: (0,1)
OK
AT+CIPENPSH?
+CIPENPSH: 0
OK
AT+CIPENPSH=1
OK
16.2.19
Information elements related to TCP/IP
The following table lists information elements which may be reported.
Information Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
UNEXPECTEDLY of service, etc). When this event happens, user’s application needs to check and close all opened sockets, and then uses
AT+NETCLOSE to release the network library if AT+NETOPEN? shows the network library is still opened.
+IPCLOSE: <client_index> , <close_reason> Socket is closed passively.
<client_index> is the link number.
<close_reason>:
0 - Closed by local, active
1 - Closed by remote, passive
2 - Closed for sending timeout
+CLIENT: < link_num
> , <server_index> , <client_IP> : <port> the index is <link_num>, the TCP server index is <server_index>. The peer IP address is <client_IP>, the peer port is
<port>.
16.2.20
Unsolicited TCP/IP command <err> Codes
3
4
5
6
7
8
9
0
1
2
10
11
255 operation succeeded
Network failure
Network not opened
Wrong parameter
Operation not supported
Failed to create socket
Failed to bind socket
TCP server is already listening
Busy
Sockets opened
Timeout
DNS parse failed for AT+CIPOPEN
Unknown error
16.3
FTP
16.3.1
AT+CFTPPORT Set FTP server port
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to set FTP server port.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPPORT=?
Read Command
AT+CFTPPORT?
Write Command
AT+CFTPPORT= <port>
Responses
+CFTPPORT: (list of supported <port> s)
OK
Responses
+CFTPPORT: <port>
OK
Responses
OK
+CME ERROR
Defined values
<port>
The FTP server port, from 1 to 65535, and default value is 21.
Examples
AT+CFTPPORT=21
OK
AT+CFTPPORT?
+CFTPPORT:21
OK
AT+CFTPPORT=?
+CFTPPORT: (1-65535)
OK
16.3.2
AT+CFTPMODE Set FTP mode
Description
This command is used to set FTP passive/proactive mode. Default is passive mode.
SIM PIN References
YES Vendor
Syntax
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Test Command
AT+CFTPMODE=?
Read Command
AT+CFTPMODE?
Write Command
AT+CFTPMODE= <mode>
Responses
+CFTPMODE: (list of supported <mode> s)
OK
Responses
+CFTPMODE: <mode>
OK
Responses
OK
+CME ERROR
Defined values
<mode>
The FTP access mode:
0 – proactive mode.
1 – passive mode.
Examples
AT+CFTPMODE=1
OK
AT+CFTPMODE?
+CFTPMODE: 1
OK
AT+CFTPMODE=?
+CFTPMODE: (0,1)
OK
16.3.3
AT+CFTPTYPE Set FTP type
Description
This command is used to set FTP type. Default is binary type.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPTYPE=?
Read Command
Responses
+CFTPTYPE: (list of supported <type> s)
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CFTPTYPE?
Write Command
AT+CFTPTYPE= <type>
+CFTPTYPE: <type>
OK
Responses
OK
+CME ERROR
Defined values
<type>
The FTP type:
I – binary type.
A – ASCII type.
Examples
AT+CFTPTYPE=A
OK
AT+CFTPTYPE?
+CFTPTYPE: A
OK
AT+CFTPTYPE=?
+CFTPTYPE: (A,I)
OK
16.3.4
AT+CFTPSERV Set FTP server domain name or IP address
Description
This command is used to set FTP server domain name or IP address.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPSERV=?
Read Command
AT+CFTPSERV?
Write Command
AT+CFTPSERV=
Responses
+CFTPSERV: “ADDRESS ”
OK
Responses
+CFTPSERV: ” <address> ”
OK
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
” <address> ” +CME ERROR
Defined values
<address>
The FTP server domain name or IP address. The maximum length is 100.
Examples
AT+CFTPSERV=”www.mydomain.com”
OK
AT+CFTPSERV?
+CFTPSERV: “www.mydomain.com”
OK
AT+CFTPSERV=?
+CFTPSERV: ”ADDRESS”
OK
AT+CFTPSERV=”10.0.0.127”
OK
16.3.5
AT+CFTPUN Set user name for FTP access
Description
This command is used to set user name for FTP server access.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPUN=?
Read Command
AT+CFTPUN?
Write Command
AT+CFTPUN=“ <name> ”
Responses
+CFTPUN: “NAME ”
OK
Responses
+CFTPUN: “ <name> ”
OK
Responses
OK
+CME ERROR
Defined values
<name>
The user name for FTP server access. The maximum length is 30.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CFTPUN=”myname”
OK
AT+CFTPUN=”anonymous”
OK
AT+CFTPUN?
+CFTPUN: “myname”
OK
AT+CFTPUN=?
+CFTPUN: ”NAME”
OK
16.3.6
AT+CFTPPW Set user password for FTP access
Description
This command is used to set user password for FTP server access.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPPW=?
Read Command
AT+CFTPPW?
Write Command
AT+CFTPPW=“ <password>
”
Responses
+CFTPPW: “PASSWORD”
OK
Responses
+CFTPPW: “ <password> ”
OK
Responses
OK
+CME ERROR
Defined values
<password>
The user password for FTP server access. The maximum length is 40.
Examples
AT+CFTPPW=”mypass”
OK
AT+CFTPPW?
+CFTPPW: “mypass”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CFTPPW=?
+CFTPPW: ”mypass”
OK
16.3.7
AT+CFTPGETFILE Get a file from FTP server to EFS
Description
This command is used to download a file from FTP server to module EFS.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPGETFILE=?
Write Command
AT+CFTPGETFILE=
“ <filepath> ” , <dir> [, <rest_siz e> ]
Responses
+CFTPGETFILE: [{non-ascii}]“FILEPATH”, (list of supported
<dir> s) [, (list of supported <rest_size> s)]
OK
Responses
OK
+CFTPGETFILE: 0
+CME ERROR
OK
+CFTPGETFILE: <err>
Defined values
<filepath>
The remote file path. When the file path doesn’t contain ”/”, this command transfers file from the current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}.
<dir>
The directory to save the downloaded file:
0 – current directory [refer to AT+FSCD ]
<rest_size>
The value for FTP “REST” command which is used for broken transfer when transferring failed last time. The range is from 0 to 2147483647.
<err>
The error code of FTP operation.
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CFTPGETFILE=”/pub/mydir/test1.txt”,0
OK
…
+CFTPGETFILE: 0
AT+CFTPGETFILE=” test2.txt”,0
OK
…
+CFTPGETFILE: 0
AT+CFTPGETFILE={non-ascii}” B2E2CAD42E747874”,0
OK
…
+CFTPGETFILE: 0
16.3.8
AT+CFTPPUTFILE Upload a file from module EFS to FTP server
Description
This command is used to upload a file from the module EFS to FTP server.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPPUTFILE=?
Write Command
AT+CFTPPUTFILE=“ <filep ath> ” , <dir> [, <rest_size> ]
Responses
+CFTPPUTFILE: [{non-ascii}] “FILEPATH”, (list of supported
<dir> s)[, (list of supported <rest_size> s)]
OK
Responses
OK
+CFTPPUTFILE: 0
+CME ERROR
OK
+CFTPPUTFILE: <err>
Defined values
<filepath>
The remote file path. When the file path doesn’t contain “/”, this command transfers file to the current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}.
<dir>
The directory that contains the file to be uploaded:
0 – current directory [refer to AT+FSCD ]
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<rest_size>
The value for FTP “REST” command which is used for broken transfer when transferring failed last time. The range is from 0 to 2147483647.
<err>
The error code of FTP operation.
Examples
AT+CFTPPUTFILE=”/pub/mydir/test1.txt”,0, 10
OK
+CFTPPUTFILE: 0
AT+CFTPPUTFILE=” test2.txt”,0
OK
…
+CFTPPUTFILE: 0
AT+CFTPPUTFILE={non-ascii}” B2E2CAD42E747874”,0
OK
…
+CFTPPUTFILE: 0
16.3.9
AT+CFTPGET Get a file from FTP server and output it to SIO
Description
This command is used to get a file from FTP server and output it to serial port. This command may have a lot of DATA transferred to DTE using serial port, The AT+CATR command is recommended to be used.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPGET=?
Write Command
AT+CFTPGET=“ <filepath>
”[, <rest_size> ]
Responses
+CFTPGET: [{non-ascii}] “FILEPATH” [, (list of supported
<rest_size> s)]
OK
Responses
OK
+CFTPGET: DATA, <len>
…
+CFTPGET: DATA, <len>
…
…
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CFTPGET: 0
If the file size is 0:
OK
+CFTPGET: 0
OK
[+CFTPGET: DATA, <len>
…
+CFTPGET: DATA, <len>
…
…]
+CFTPGET: <err>
Defined values
<filepath>
The remote file path. When the file path doesn’t contain ”/” , this command transfer file from the current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}.
<rest_size>
The value for FTP “REST” command which is used for broken transfer when transferring failed last time. The range is from 0 to 2147483647.
<len>
The length of FTP data contained in this packet.
<err>
The error code of FTP operation.
Examples
AT+CFTPGET=”/pub/mydir/test1.txt”, 10
OK
+CFTPGET: DATA, 1020,
…
+CFTPGET: DATA, 1058,
…
…
+CFTPGET: 0
AT+CFTPGET={non-ascii}”/2F74657374646972/B2E2CAD42E747874”
OK
+CFTPGET: DATA, 1020,
…
+CFTPGET: 0
AT+CFTPGET=?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CFTPGET: [{non-ascii}]“FILEPATH” [,(0-2147483647)]
OK
16.3.10 AT+CFTPPUT Upload the DATA from SIO to FTP server
Description
This command is used to upload the DATA from serial port to FTP server as a file . Each <Ctrl+Z> character present in the data flow of serial port when downloading FTP data will be coded as
<ETX><Ctrl+Z>. Each <ETX> character will be coded as <ETX><ETX>. Single <Ctrl+Z> means end of the FTP data.
<ETX> is 0x03, and <Ctrl+Z> is 0x1A.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPPUT=?
Execution Command
AT+CFTPPUT=“ <filepath> ”
[, <rest_size> ]
Responses
+CFTPPUT: [{non-ascii}] “FILEPATH” [, (list of supported
<rest_size> s)]
OK
Responses
+CFTPPUT: BEGIN
OK
+CME ERROR
[+CFTPPUT: BEGIN]
+CFTPPUT: <err_code>
ERROR
Defined values
<filepath>
The remote file path. When the file path doesn’t contain “/”, this command transfers file to the current remote FTP directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}.
<rest_size>
The value for FTP “REST” command which is used for broken transfer when transferring failed last time. The range is from 0 to 2147483647.
<err_code>
Refer to “Unsolicited FTP Codes”.
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CFTPPUT=”/pub/mydir/test1.txt”, 20
+CFTPPUT: BEGIN
…..<Ctrl+Z>
OK
AT+CFTPPUT={non-ascii}”/2F74657374646972/B2E2CAD42E747874”
+CFTPPUT: BEGIN
…..<Ctrl+Z>
OK
AT+CFTPPUT=?
+CFTPPUT: [{non-ascii}]“FILEPATH” [,(0-2147483647)]
OK
16.3.11 AT+CFTPLIST List the items in the directory on FTP server
Description
This command is used to list the items in the specified directory on FTP server
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPLIST=?
Write Command
AT+CFTPLIST=” <dir> ”
Responses
+CFTPLIST: [{non-ascii}] “FILEPATH”
OK
Responses
OK
[+CFTPLIST: DATA, <len>
…]
+CFTPLIST: <err>
+CME ERROR
Defined values
<dir>
The directory to be listed. If the directory contains non-ASCII characters, the <dir> parameter should contain a prefix of {non-ascii}.
<len>
The length of data reported
<err>
The result code of the listing
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CFTPLIST=”/testd”
OK
+CFTPLIST: DATA,193 drw-rw-rw- 1 user group 0 Sep 1 18:01 . drw-rw-rw- 1 user group 0 Sep 1 18:01 ..
-rw-rw-rw- 1 user group 2017 Sep 1 17:24 19800106_000128.jpg
+CFTPLIST: 0
16.3.12 AT+CFTPMKD Create a new directory on FTP server
Description
This command is used to create a new directory on the FTP server. The maximum length of the full path name is 256.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPMKD=?
Write Command
AT+CFTPMKD=” <dir> ”
Responses
+CFTPMKD: [{non-ascii}]”DIR”
OK
Responses
OK
+CFTPMKD: <err>
ERROR
Defined values
<dir>
The directory to be created. If the directory contains non-ASCII characters, the <dir> parameter should contain a prefix of {non-ascii}.
<err>
The result code of the command
Examples
AT+CFTPMKD=”/testdir”
OK
AT+CFTPMKD={non-ascii}”74657374646972”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
16.3.13 AT+CFTPRMD Delete a directory on FTP server
Description
This command is used to delete a directory on FTP server
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPRMD=?
Write Command
AT+CFTPRMD=” <dir> ”
Responses
+CFTPRMD: [{non-ascii}]”DIR”
OK
Responses
OK
+CFTPRMD: <err>
ERROR
Defined values
<dir>
The directory to be removed. If the directory contains non-ASCII characters, the <dir> parameter should contain a prefix of {non-ascii}.
<err>
The result code of the command
Examples
AT+CFTPRMD=”/testdir”
OK
AT+CFTPRMD={non-ascii}”74657374646972”
OK
16.3.14 AT+CFTPDELE Delete a file on FTP server
Description
This command is used to delete a file on FTP server
SIM PIN References
YES Vendor
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Test Command
AT+CFTPDELE=?
Write Command
AT+CFTPDELE=” <filenam e> ”
Responses
+CFTPDELE: [{non-ascii}]”FILENAME”
OK
Responses
OK
+CFTPDELE: <err>
ERROR
Defined values
<filename>
The name of the file to be deleted. If the file name contains non-ASCII characters, the <filename> parameter should contain a prefix of {non-ascii}.
<err>
The result code of the command
Examples
AT+CFTPDELE=”test”
OK
AT+CFTPDELE={non-ascii}”74657374”
OK
16.3.15 Unsolicited FTP Codes (Summary of CME ERROR Codes)
210
211
212
213
214
205
206
207
208
209
Code of <err>
201
202
203
204
Description
Unknown error for FTP
FTP task is busy
Failed to resolve server address
FTP timeout
Failed to read file
Failed to write file
Not allowed in current state
Failed to login
Failed to logout
Failed to transfer data
FTP command rejected by server
Memory error
Invalid parameter
Network error
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
215
216
217
218
219
Failed to connect socket
Failed to send data using socket
Failed to receive data using socket
Failed to verify user name and password
Socket connect timeout
16.4
FTPS
These AT Command of FTPS related need the AT+CATR command to be set with the used port.
AT+CATR=0 may cause some problem.
16.4.1
AT+CFTPSSTART Acquire FTPS protocol stack
Description
This command is used to acquire FTPS protocol stack.
SIM PIN References
YES Vendor
Syntax
Execute Command
AT+CFTPSSTART
Responses
OK
+CFTPSSTART: <err>
+CFTPSSTART: <err>
OK
ERROR
Defined values
<err>
The result code of the acquiring FTP/FTPS stack. 0 is success. Other values are failure.
Examples
AT+CFTPSSTART
OK
+CFTPSSTART: 0
16.4.2
AT+CFTPSSTOP Stop FTPS protocol stack
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to stop FTPS protocol stack. Currently only explicit FTPS mode is supported.
SIM PIN References
YES Vendor
Syntax
Execute Command
AT+CFTPSSTOP
Responses
OK
+CFTPSSTOP: <err>
+CFTPSSTOP: <err>
OK
ERROR
Defined values
<err>
The result code of the stopping FTP/FTPS stack. 0 is success. Other values are failure.
Examples
AT+CFTPSSTOP
OK
+CFTPSSTOP: 0
16.4.3
AT+CFTPSLOGIN Login the FTPS server
Description
This command is used to login the FTPS server. Each time, AT+CFTPSSTART command must be executed before executing AT+CFTPSLOGIN command.
SIM PIN References
YES Vendor
Syntax
Write Command Responses
AT+CFTPSLOGIN=” <host>
”, <port> ,” <username> ”, ” <p assword> ”[ <server_type> ]
OK
+CFTPSLOGIN: <err>
+CFTPSLOGIN: <err>
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<host>
The host address, maximum length is 256
<port>
The host listening port for SSL, the range is from 1 to 65535
<username>
The user name, maximum length is 256
<password>
The user password, maximum length is 256
<server_type>
The type of server:
0 – FTP server.
1 – Explicit FTPS server with AUTH SSL.
2 – Explicit FTPS server with AUTH TLS.
3 – Implicit FTPS server.
<err>
The result code of the FTP/FTPS login. 0 is success. Other values are failure.
Examples
AT+CFTPSLOGIN=”www.myftpsserver.com”,990, ”myname”, ”mypassword”,3
OK
+CFTPSLOGIN: 0
16.4.4
AT+CFTPSLOGOUT Logout the FTPS server
Description
This command is used to logout the FTPS server.
Syntax
Execute Command
AT+CFTPSLOGOUT
Responses
OK
+CFTPSLOGOUT: <err>
+CFTPSLOGOUT: <err>
OK
ERROR
Defined values
<err>
The result code of FTP/FTPS logout. 0 is success. Other values are failure.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CFTPSLOGOUT
OK
+CFTPSLOGOUT: 0
16.4.5
AT+CFTPSMKD Create a new directory on FTPS server
Description
This command is used to create a new directory on the FTPS server. The maximum length of the full path name is 256.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPSMKD=?
Write Command
AT+CFTPSMKD=” <dir> ”
Responses
+CFTPSMKD: ”DIR”
OK
Responses
OK
+CFTPSMKD: <err>
ERROR
ERROR
Defined values
<dir>
The directory to be created
Examples
AT+CFTPSMKD=”testdir”
OK
AT+CFTPSMKD={non-ascii}”74657374646972”
OK
16.4.6
AT+CFTPSRMD Delete a directory on FTPS server
Description
This command is used to delete a directory on FTPS server
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
YES Vendor
Syntax
Test Command
AT+CFTPSRMD=?
Write Command
AT+CFTPSRMD=” <dir> ”
Responses
+CFTPSRMD: ”DIR”
OK
Responses
OK
+CFTPSRMD: <err>
ERROR
ERROR
Defined values
<dir>
The directory to be removed. If the directory contains non-ASCII characters, the <dir> parameter should contain a prefix of {non-ascii}.
Examples
AT+CFTPSRMD=”testdir”
OK
AT+CFTPSRMD={non-ascii}”74657374646972”
OK
16.4.7
AT+CFTPSDELE Delete a file on FTPS server
Description
This command is used to delete a file on FTPS server
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPSDELE=?
Write Command
AT+CFTPSDELE=” <filena me> ”
Responses
+CFTPSDELE: ”FILENAME”
OK
Responses
OK
+CFTPSDELE: <err>
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
ERROR
Defined values
<filename>
The name of the file to be deleted. If the file name contains non-ASCII characters, the <filename> parameter should contain a prefix of {non-ascii}.
Examples
AT+CFTPSDELE=”test”
OK
AT+CFTPDELE={non-ascii}”74657374”
OK
16.4.8
AT+CFTPSCWD Change the current directory on FTPS server
Description
This command is used to change the current directory on FTPS server
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPSCWD=?
Write Command
AT+CFTPSCWD=” <dir> ”
Responses
+CFTPSCWD: ”DIR”
OK
Responses
OK
+CFTPSCWD: <err>
ERROR
ERROR
Defined values
<dir>
The directory to be changed. If the directory contains non-ASCII characters, the <dir> parameter should contain a prefix of {non-ascii}.
Examples
AT+CFTPSCWD=”testdir”
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CFTPSCWD={non-ascii}”74657374646972”
OK
16.4.9
AT+CFTPSPWD Get the current directory on FTPS server
Description
This command is used to get the current directory on FTPS server.
SIM PIN References
YES Vendor
Syntax
Execute Command
AT+CFTPSPWD
Responses
+CFTPSPWD: ” <dir> ”
OK
+CFTPSPWD: <err>
ERROR
ERROR
Defined values
<dir>
The current directory on FTPS server.
Examples
AT+CFTPSPWD
+CFTPSPWD: “/testdir”
OK
16.4.10 AT+CFTPSTYPE Set the transfer type on FTPS server
Description
This command is used to set the transfer type on FTPS server
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPSTYPE=?
Responses
+CFTPSTYPE: (A,I)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+CFTPSTYPE?
Write Command
AT+CFTPSTYPE= <type>
OK
Responses
+CFTPSTYPE: <type>
OK
Responses
OK
+CFTPSTYPE: <err>
ERROR
ERROR
Defined values
<type>
The type of transferring:
A – ASCII.
I – Binary.
Examples
AT+CFTPSTYPE=A
OK
16.4.11 AT+CFTPSLIST List the items in the directory on FTPS server
Description
This command is used to list the items in the specified directory on FTPS server
SIM PIN References
YES Vendor
Syntax
Write Command
AT+CFTPSLIST=” <dir> ”[,< using_cache >]
Responses
If the <using_cache> is 0 (default):
OK
+CFTPSLIST: DATA, <len>
…
+CFTPSLIST: <err>
If the <using_cache> is 1:
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Execute Command
AT+CFTPSLIST
+CFTPS: RECV EVENT
AT+CFTPSCACHERD?
+CFTPSCACHERD: 102400
OK
//output cached data now
AT+CFTPSCACHERD
+CFTPSLIST: DATA, <len>
…
OK
......
+CFTPSLIST: <err>
ERROR
Responses
OK
+CFTPSLIST: DATA, <len>
…
+CFTPSLIST: <err>
OK
+CFTPSLIST: <err>
+CFTPSLIST: <err>
ERROR
ERROR
Defined values
<dir>
The directory to be listed. If the directory contains non-ASCII characters, the <dir> parameter should contain a prefix of {non-ascii}.
<len>
The length of data reported
<err>
The result code of the listing
<using_cache>
0 – Do not use cache
1 – Use cache(Data will be output using AT+CFTPSCACHERD command)
Examples
AT+CFTPSLIST=”/testd”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
+CFTPSLIST: DATA,193 drw-rw-rw- 1 user group 0 Sep 1 18:01 . drw-rw-rw- 1 user group 0 Sep 1 18:01 ..
-rw-rw-rw- 1 user group 2017 Sep 1 17:24 19800106_000128.jpg
+CFTPSLIST: 0
AT+CFTPSLIST
OK
+CFTPSLIST: DATA,193 drw-rw-rw- 1 user group 0 Sep 1 18:01 . drw-rw-rw- 1 user group 0 Sep 1 18:01 ..
-rw-rw-rw- 1 user group 2017 Sep 1 17:24 19800106_000128.jpg
+CFTPSLIST: 0
16.4.12 AT+CFTPSGETFILE Get a file from FTPS server to EFS
Description
This command is used to download a file from FTPS server to module EFS.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPSGETFILE=?
Write Command
AT+CFTPGETFILE=
“ <filepath> ” , <dir> [, <rest_siz e> ]
Responses
OK
Responses
OK
+CFTPSGETFILE: 0
+CFTPSGETFILE: <err>
ERROR
ERROR
OK
+CFTPSGETFILE: <err>
Defined values
<filepath>
The remote file path. When the file path doesn’t contain ”/”, this command transfers file from the current remote FTPS directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<dir>
The directory to save the downloaded file, refer to AT+FSCD .
<rest_size>
The rest size of the file.
<err>
The error code of FTPS operation.
Examples
AT+CFTPSGETFILE=”/pub/mydir/test1.txt”,1
OK
…
+CFTPSGETFILE: 0
AT+CFTPSGETFILE=” test2.txt”,2
OK
…
+CFTPSGETFILE: 0
AT+CFTPSGETFILE={non-ascii}” B2E2CAD42E747874”,2
OK
…
+CFTPSGETFILE: 0
AT+CFTSPGETFILE=?
OK
16.4.13 AT+CFTPSPUTFILE Upload a file in module EFS to FTPS server
Description
This command is used to upload a file in the module EFS to FTPS server.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPSPUTFILE=?
Write Command
AT+CFTPSPUTFILE=
“ <filepath> ” , <dir> [, <rest_siz e> ]
Responses
OK
Responses
OK
+CFTPSPUTFILE: 0
+CFTPSPUTFILE: <err>
ERROR
ERROR
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CFTPSPUTFILE: <err>
Defined values
<filepath>
The remote file path. When the file path doesn’t contain “/”, this command transfers file to the current remote FTPS directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}.
<dir>
The directory that contains the file to be uploaded, refer to AT+FSCD .
<rest_size>
The rest size of the file.
<err>
The error code of FTPS operation.
Examples
AT+CFTPSPUTFILE=”/pub/mydir/test1.txt”,1
OK
AT+CFTPSPUTFILE=” test2.txt”,1
OK
…
+CFTPSPUTFILE: 0
AT+CFTPSPUTFILE={non-ascii}” B2E2CAD42E747874”,1
OK
…
+CFTPSPUTFILE: 0
AT+CFTPSPUTFILE=?
OK
16.4.14 AT+CFTPSGET Get a file from FTPS server to serial port
Description
This command is used to get a file from FTPS server and output it to serial port. This command may have a lot of DATA transferred to DTE using serial port, The AT+CATR command is recommended to be used.
SIM PIN References
YES Vendor
Syntax
Test Command Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CFTPSGET=?
Write Command
AT+CFTPSGET=
“ <filepath> ”[,< rest_size >[,< using_cache >]]
OK
Responses
If the <using_cache> is 0 (default):
OK
+CFTPSGET: DATA, <len>
…
+CFTPSGET: DATA, <len>
…
…
+CFTPSGET: 0
If the <using_cache> is 1:
OK
+CFTPS: RECV EVENT
AT+CFTPSCACHERD?
+CFTPSCACHERD: 102400
OK
//output cached data now:
AT+CFTPSCACHERD
+CFTPSGET: DATA, <len>
…
OK
......
+CFTPSGET: 0
+CFTPSGET: <err>
ERROR
ERROR
+CFTPSGET: DATA, <len>
…
+CFTPSGET: DATA, <len>
…
…
+CFTPSGET: <err>
Defined values
<filepath>
The remote file path. When the file path doesn’t contain ”/” , this command transfer file from the
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set current remote FTPS directory. If the file path contains non-ASCII characters, the file path parameter should contain a prefix of {non-ascii}.
<rest_size>
The rest size of the file.
<len>
The length of FTPS data contained in this packet.
<err>
The error code of FTPS operation.
<using_cache>
0 – Do not use cache
1 – Use cache(Data will be output using AT+CFTPSCACHERD command)
Examples
AT+CFTPSGET=”/pub/mydir/test1.txt”
OK
+CFTPSGET: DATA, 1020,
…
+CFTPSGET: DATA, 1058,
…
…
+CFTPSGET: 0
AT+CFTPSGET={non-ascii}”/2F74657374646972/B2E2CAD42E747874”
OK
+CFTPSGET: DATA, 1020,
…
+CFTPSGET: 0
AT+CFTPSGET=?
OK
16.4.15 AT+CFTPSPUT Put a file to FTPS server
Description
This command is used to put a file to FTPS server through serial port. The AT+CFTPSPUT=
[“<filepath>”,]<len>[,<rest_size>] is used to download the data to be sent. The
AT+CFTPSPUT is used to wait the result of sending. Only parameter “<filepath>” is provided,
<rest_size> is optional, in other case <rest_size> is not used.
SIM PIN References
YES Vendor
Syntax
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Test Command
AT+CFTPSPUT=?
Read Command
AT+CFTPSPUT?
Write Command
AT+CFTPSPUT=[“ <filepath
> ”,] <len>[,<rest_size>]
Execute Command
Responses
OK
Responses
+CFTPSPUT: <unsent_len>
OK
Responses
>
OK
+CFTPSPUT: <result>
ERROR
ERROR
Responses
AT+CFTPSPUT OK
+CFTPSPUT: <result>
ERROR
Defined values
<filepath>
The path of the file on FTPS server.
<unsent_len>
The length of the data in the sending buffer which is waiting to be sent.
<len>
The length of the data to send, the maximum length is 1024.
<rest_size>
The rest size of the file.
<result>
The final result of the sending.
Examples
AT+CFTPSPUT=”t1.txt”,10
>testcontent
OK
AT+CFTPSPUT
OK
+CFTPSSPUT: 0
AT+CFTPSPUT?
+CFTPSPUT: 88
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.4.16 AT+CFTPSSIZE Get the size of a file on FTPS server
Description
This command is used to get the size of file on FTPS server
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPSSIZE=?
Write Command
AT+CFTPSSIZE=” <filenam e> ”
Responses
OK
Responses
OK
+CFTPSSIZE: <err> [, <fsize> ]
ERROR
Defined values
<filename>
The name of the file to be deleted. If the file name contains non-ASCII characters, the <filename> parameter should contain a prefix of {non-ascii}.
<err>
The result of get file size. O is successful. Only when successful, the second parameter of URC
+CFTPSSIZE is provided. When failure, Only +CFTPSSIZE: <err> is reported.
<fsize>
The size of the file in byte.
Examples
AT+CFTPSSIZE=”test.txt”
+CFTPSSIZE: 0, 1024
OK
AT+CFTPSSIZE={non-ascii}”74657374”
+CFTPSSIZE: 0, 1024
OK
16.4.17 AT+CFTPSCACHERD Output cached data to MCU
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to output cached data(generated by AT+CFTPSGET/AT+CFTPSLIST) to
MCU.
SIM PIN References
YES Vendor
Syntax
Read Command
AT+CFTPSCACHERD?
Execute Command
AT+CFTPSCACHERD
Responses
+CFTPSCACHERD: <len>
OK
Responses
If cache data is AT+CFTPSGET:
+CFTPSGET: DATA,< out_len ><CR><LF>
…
OK
If the cache data is AT+CFTPSLIST:
+CFTPSLIST: DATA,< out_len ><CR><LF>
…
OK
ERROR
Defined values
<len>
The bytes of data cached in FTPS module.
<out_len>
The bytes of data to output. The maximum value is 1024 for each AT+CFTPSCACHERD calling.
Examples
AT+CFTPSCACHERD?
+CFTPSCACHERD: 102400
OK
AT+CFTPSCACHERD
+CFTPSGET: DATA, 1024
…
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.4.18 AT+CFTPSSTATE Get the state of FTPS stack
Description
This command is used to get the state of FTPS stack.
SIM PIN References
NO Vendor
Syntax
Execute Command
AT+CFTPSSTATE
Responses
+CFTPSTATE: <state>,<operation>
OK
ERROR
Defined values
<state>
0 – None
1 – Accquired FTPS stack
2 – Opening network
3 – Closing network
4 – Opened network
5 – Logging in
6 – Login
7 – Operating
8 – Logging out
<operation>
0 – None
1 – Login
2 – Logout
3 – List
4 – Cwd
5 – Pwd
6 – Mkd
7 – Rmd
8 – Dele
9 – Type
10 – Get
11 – Put
12 – Size
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CFTPSSTATE
+CFTPSSTATE: 0,0
OK
16.4.19 AT+CFTPSTO Set FTPS receive timeout value
Description
This command is used to set timeout value for FTPS receive timeout parameter.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CFTPSTO=?
Read Command
AT+CFTPSTO?
Responses
+CFTPSTO: (10-120)
OK
Responses
+CFTPSTO: <recv_timeout>
OK
Write Command
AT+CFTPSTO= <recv_ti meout>
Responses
OK
ERROR
Defined values
<recv_timeout>
Timeout value for FTPS receiving operation, default value is 120 seconds. The range is from 10 seconds to 120 seconds.
Examples
AT+CFTPSTO?
+CFTPSTO: 120
OK
AT+CFTPSTO=10
OK
16.4.20 AT+CFTPSABORT Abort and Stop FTPS protocol stack
Description
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
This command is used to abort and stop FTPS protocol stack. This command can only be used in FTPS logged-in state.
SIM PIN References
YES Vendor
Syntax
Execute Command
AT+CFTPSABORT
Responses
OK
+CFTPSABORT: <err>
+CFTPSABORT: <err>
OK
ERROR
Defined values
<err>
The result code of the aborting FTP/FTPS stack. 0 is success. Other values are failure.
Examples
AT+CFTPSABORT
OK
+CFTPSABORT: 0
16.4.21 AT+CFTPSSINGLEIP Set FTPS data socket address type
Description
This command is used to set FTPS server data socket IP address type
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CFTPSSINGLEIP=?
Responses
+CFTPSSINGLEIP: (0,1)
Read Command
AT+CFTPSSINGLEIP?
Write Command
OK
Responses
+ CFTPSSINGLEIP: <singleip>
OK
Responses
AT+CFTPSSINGLEIP= <sin OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3
4
5
6
7
0
1
2
8
9
10 gleip> ERROR
Defined values
<singleip>
The FTPS data socket IP address type:
0 – decided by PORT response from FTPS server
1 – the same as the control socket.
Examples
AT+CFTPSSINGLEIP=1
OK
AT+CFTPSSINGLEIP?
+CFTPSSINGLEIP:1
OK
AT+CFTPSSINGLEIP=?
+CFTPSSINGLEIP: (0,1)
OK
16.4.22 Unsolicited FTPS Codes
Code
CLOSED
Description
16.4.23 Unsolicited FTPS command <err> Codes
FTPS operation succeeded
SSL verify alert
Unknown FTPS error
FTPS busy
FTPS server closed connection
Timeout
FTPS transfer failed
FTPS memory error
Invalid parameter
Operation rejected by FTPS server
Network error
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.5
HTTPS
16.5.1
AT+CHTTPSSTART Acquire HTTPS protocol stack
Description
This command is used to acquire HTTPS protocol stack.
SIM PIN References
YES Vendor
Syntax
Execute Command
AT+CHTTPSSTART
Responses
OK
ERROR
Examples
AT+CHTTPSSTART
OK
16.5.2
AT+CHTTPSSTOP Stop HTTPS protocol stack
Description
This command is used to stop HTTPS protocol stack.
SIM PIN References
YES Vendor
Syntax
Execute Command
AT+CHTTPSSTOP
Responses
OK
ERROR
Examples
AT+CHTTPSSTOP
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.5.3
AT+CHTTPSOPSE Open HTTPS session
Description
This command is used to open a new HTTPS session. Every time, AT+CHTTPSSTART command must be executed before executing AT+CHTTPSOPSE command.
SIM PIN References
YES Vendor
Syntax
Write Command
AT+CHTTPSOPSE=” <host
> ”, <port> [, <server_type> ]
Responses
OK
ERROR
Defined values
<host>
The host address
<port>
The host listening port for SSL
<server_type>
The type of server:
1 – HTTP server.
2 – HTTPS server with SSL3.0/TLS1.0 supported.
Examples
AT+CHTTPSOPSE=”www.mywebsite.com”,443
OK
16.5.4
AT+CHTTPSCLSE Close HTTPS session
Description
This command is used to close the opened HTTPS session.
SIM PIN References
YES Vendor
Syntax
Execute Command
AT+CHTTPSCLSE
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
ERROR
Examples
AT+CHTTPSCLSE
OK
16.5.5
AT+CHTTPSSEND Send HTTPS request
Description
This command is used to send HTTPS request. The AT+CHTTPSSEND=<len> is used to download the data to be sent. The AT+CHTTPSSEND is used to wait the result of sending.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CHTTPSSEND=?
Read Command
AT+CHTTPSSEND?
Write Command
AT+ CHTTPSSEND = <len>
Execute Command
Responses
+CHTTPSSEND: (1-4096)
OK
Responses
+CHTTPSSEND: <unsent_len>
OK
Responses
>
OK
ERROR
Responses
AT+CHTTPSSEND OK
+CHTTPSSEND: <result>
ERROR
Defined values
<unsent_len>
The length of the data in the sending buffer which is waiting to be sent.
<len>
The length of the data to send
<result>
The final result of the sending.
0 – ok
1 – unknown error
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
2 – busy
3 – server closed
4 – timeout
5 – transfer failed
6 – memory error
7 – invalid parameter
8 – network error
Examples
AT+CHTTPSSEND=88
>GET / HTTP/1.1
Host: www.mywebsite.com
User-Agent: MY WEB AGENT
Content-Length: 0
OK
AT+CHTTPSSEND
OK
+CHTTPSSEND: 0
AT+CHTTPSSEND?
+CHTTPSSEND: 88
OK
16.5.6
AT+CHTTPSRECV Receive HTTPS response
Description
This command is used to receive HTTPS response after sending HTTPS request.
SIM PIN References
YES Vendor
Syntax
Read Command
AT+CHTTPSRECV?
Write Command
Responses
+CHTTPSRECV: LEN, <cache_len>
OK
Responses
AT+CHTTPSRECV= <max_ recv_len>
OK
+CHTTPSRECV: DATA, <len>
…
+CHTTPSRECV: DATA, <len>
…
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CHTTPSRECV: <result>
+CHTTPSRECV: <result>
ERROR
ERROR
Defined values
<len>
The length of the data received.
<max_recv_len>
Maximum bytes of data to receive in the current AT+CHTTPSRECV calling. Minimum is 1.
<cache_len>
The cache length.
<result>
The final result of the receiving.
0 – ok
1 – unknown error
2 – busy
3 – server closed
4 – timeout
5 – transfer failed
6 – memory error
7 – invalid parameter
8 – network error
Examples
AT+CHTTPSRECV=249
OK
+CHTTPSRECV: DATA,249
HTTP/1.1 200 OK
Content-Type: text/html
Content-Language: zh-CN
Content-Length: 57
Date: Tue, 31 Mar 2009 01:56:05 GMT
Connection: Close
Proxy-Connection: Close
<html>
<header>test</header>
<body>
Test body
</body>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CHTTPSRECV: 0
16.5.7
AT+CHTTPSSTATE Get the state of HTTPS stack
Description
This command is used to get the state of HTTPS stack.
SIM PIN References
NO Vendor
Syntax
Execute Command
AT+CHTTPSSTATE
Responses
+CHTTPSSTATE: <state>
OK
ERROR
Defined values
<state>
0 – None
1 – Accquired HTTPS
2 – Opening network
3 – Closing network
4 – Opened network
5 – Closing session
6 – Opening session
7 – Opened session.
Examples
AT+CHTTPSSTATE
+CHTTPSSTATE: 0
OK
16.5.8
Unsolicited HTTPS Codes
Code Description
+CHTTPS: RECV EVENT When the AT+CHTTPSRECV is not called, and there is data cached in the receiving buffer, this event will be reported.
+CHTTPSNOTIFY: PEER
The HTTPS session is closed by the server.
CLOSED
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.5.9
Unsolicited HTTPS command <err> Codes
3
4
5
6
0
1
2
7
8
Operation succeeded
Unknown error
Busy
Server closed
Operation timeout
Transfer failed
Memory error
Invalid parameter
Network error
16.6
HTP
These AT Commands of HTP related are used to synchronize system time with HTTP server.
16.6.1
AT+CHTPSERV Set HTP server info
Description
This command is used to add or delete HTP server information. There are maximum 16 HTP servers.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CHTPSERV=?
Read Command
AT+CHTPSERV?
Write Command
Responses
+CHTPSERV:"ADD","HOST",(1-65535),
(0-1)[,"PROXY",(1-65535)]
+CHTPSERV: "DEL",(0-15)
OK
Responses
+CHTPSERV: <index> " <host> ", <port> , <http_version>
[," <proxy> ", <proxy_port> ]
…
+CHTPSERV: <index> " <host> ", <port> [," <proxy> ", < proxy_port> ]
OK
OK (if HTP server not setted)
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CHTPSERV=
" <cmd> "," <host_or_idx> "[, < port> , <http_version>
[," <proxy> ", <proxy_port> ]]
OK
ERROR
Defined values
<cmd>
This command to operate the HTP server list .
“ADD”: add a HTP server item to the list
“DEL”: delete a HTP server item from the list
<host_or_idx>
If the <cmd> is “ADD”, this field is the same as <host>, needs quotation marks; If the <cmd> is
“DEL”, this field is the index of the HTP server item to be deleted from the list, does not need quotation marks.
<host>
The HTP server address.
<port>
The HTP server port.
<http_version>
The HTTP version of the HTP server:
0HTTP 1.0
1HTTP 1.1
<proxy>
The proxy address
<proxy_port>
The port of the proxy
<index>
The HTP server index.
Examples
AT+CHTPSERV=”ADD”,”www.google.com”,80,1
OK
16.6.2
AT+CHTPUPDATE Updating date time using HTP protocol
Description
This command is used to updating date time using HTP protocol.
SIM PIN References
YES Vendor
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Test Command
AT+CHTPUPDATE=?
Read Command
AT+CHTPUPDATE?
Execute Command
AT+CHTPUPDATE
Responses
OK
Response
+CHTPUPDATE:<status>
OK
Responses
OK
+CHTPUPDATE: <err>
ERROR
Defined values
<status>
The status of HTP module:
Updating: HTP module is synchronizing date time
NULL: HTP module is idle now
<err>
The result of the HTP updating
Examples
AT+CHTPUPDATE
OK
+CHTPUPDATE: 0
16.6.3
Unsolicited HTP Codes
Code of <err>
0
1
2
3
4
Description
Operation succeeded
Unknown error
Wrong parameter
Wrong date and time calculated
Network error
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.7
SMTP
16.7.1
AT+SMTPSRV Set SMTP server address and port number
Description
This synchronous command is used to set SMTP server’s address and server’s port number. SMTP client will initiate TCP session with the specified server to send an e-mail. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current SMTP server address and port number.
Execution command will clear SMTP server address and set the port number as default value.
NOTE: After an e-mail is sent successfully or unsuccessfully, SMTP server address and port number won’t be cleared.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SMTPSRV=?
Read Command
AT+SMTPSRV?
Write Command
AT+SMTPSRV= <server>
[, <port> ]
Execution Command
AT+SMTPSRV
Responses
+SMTPSRV: (list of supported <port> s)
OK
Responses
+SMTPSRV: <server> , <port>
OK
Responses
OK
Responses
OK
Defined values
<server>
SMTP server address, non empty string with double quotes, mandatory and ASCII text string up to
127 characters.
<port>
Port number of SMTP server in decimal format, from 1 to 65535, and default port is 25 for SMTP.
Examples
AT+SMTPSRV="smtp.server.com",25
OK
AT+SMTPSRV?
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+SMTPSRV: "smtp.server.com", 25
OK
AT+SMTPSRV
OK
AT+SMTPSRV?
+SMTPSRV: "", 25
OK
16.7.2
AT+SMTPAUTH SMTP server authentication
Description
This synchronous command is used to control SMTP authentication during connection with SMTP server. If SMTP server requires authentication while logging in the server, TE must set the authentication control flag and provide user name and password correctly before sending an e-mail.
If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current SMTP server authentication control flag, if the flag is 0, both <user> and <pwd> are empty strings.
Execution Command cancels SMTP server authentication and clear user name and password.
NOTE: After an e-mail is sent successfully or unsuccessfully, server authentication won’t be cleared.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SMTPAUTH=?
Read Command
AT+SMTPAUTH?
Write Command
AT+SMTPAUTH=
<flag> [, <user> , <pwd> ]
Execution Command
AT+SMTPAUTH
Responses
+SMTPAUTH: (list of supported <flag> s)
OK
Responses
+SMTPAUTH: <flag>, <user>, <pwd>
OK
Responses
OK
Responses
OK
Defined values
<flag>
SMTP server authentication control flag, integer type.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
0 – SMTP server doesn’t require authentication, factory value.
1 – SMTP server requires authentication.
<user>
User name to be used for SMTP authentication, non empty string with double quotes and up to 127 characters.
<pwd>
Password to be used for SMTP authentication, string with double quotes and up to 127 characters.
NOTE: If <flag> is 0, <user> and <pwd> must be omitted (i.e. only <flag> is present).
Examples
AT+SMTPAUTH?
+SMTPAUTH: 0, “”, “”
OK
AT+SMTPAUTH=1,”username”,”password”
OK
AT+SMTPAUTH?
+SMTPAUTH: 1, ”username”, ”password”
OK
AT+SMTPAUTH
OK
AT+SMTPAUTH?
+SMTPAUTH: 0, “”, “”
OK
16.7.3
AT+SMTPFROM Sender address and name
Description
This synchronous command is used to set sender’s address and name, which are used to construct e-mail header. The sender’s address must be correct if the SMTP server requries, and if the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current sender’s address and name.
Execution command will clear sender’s address and name.
NOTE: After an e-mail is sent successfully or unsuccessfully, sender address and name won’t be cleared.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SMTPFROM=?
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+SMTPFROM?
Write Command
AT+SMTPFROM=
<saddr> [, <sname> ]
Execution Command
AT+SMTPFROM
Responses
+SMTPFROM: <saddr> , <sname>
OK
Responses
OK
Responses
OK
Defined values
<saddr>
E-mail sender address (MAIL FROM), non empty string with double quotes, mandatory and ASCII text up to 127 characters. <saddr> will be present in the header of the e-mail sent by SMTP client in the field: “ From: ”.
<sname>
E-mail sender name, string with double quotes, and alphanumeric ASCII text up to 63 characters.
<sname> will be present in the header of the e-mail sent by SMTP client in the field: “ From: ”.
Examples
AT+SMTPFROM="[email protected]","sendername"
OK
AT+SMTPFROM?
+SMTPFROM: "[email protected]", "sendername"
OK
AT+SMTPFROM
OK
AT+SMTPFROM?
+SMTPFROM: "", ""
OK
16.7.4
AT+SMTPRCPT Recipient address and name (TO/CC/BCC)
Description
This synchronous command is used to set recipient address/name and kind (TO/CC/BCC). If only the parameter of “kind” is present, the command will clear all recipients of this kind, and if only parameters of “kind” and “index” are present, the command will clear the specified recipient. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current recipient address/name and kind list.
Execution command will clear all recipient information.
NOTE: After an e-mail is sent successfully, all recipients will be cleared, if unsuccessfully, they won’t be cleared.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SMTPRCPT=?
Read Command
AT+SMTPRCPT?
Responses
+SMTPRCPT: (list of supported <kind> s), (list of supported
<index> s)
OK
Responses
[+SMTPRCPT: <kind> , <index> , <raddr> , <rname>
[<CR><LF>…]]
OK
OK
Write Command
AT+SMTPRCPT= <kind> [,
<index> [, <raddr> [, <rname> ]
]]
Execution Command
AT+SMTPRCPT
Responses
OK
Responses
OK
Defined values
<kind>
Recipient kind, the kinds of TO and CC are used to construct e-mail header in the field: “ To: ” or
“ Cc: ”.
0 – TO, normal recipient.
1 – CC, Carbon Copy recipient.
2 – BCC, Blind Carbon Copy recipient.
<index>
Index of the kind of recipient, decimal format, and from 0 to 4.
<raddr>
Recipient address, non empty string with double quotes, and up to 127 characters.
<rname>
Recipient name, string type with double quotes, and up to 63 characters.
Examples
AT+SMTPRCPT=0, 0, “[email protected]”, “rcptname_to”
OK
AT+SMTPRCPT?
+SMTPRCPT: 0, 0, “[email protected]”, “rcptname_to”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+SMTPRCPT=1, 0, “[email protected]”, “rcptname_cc”
OK
AT+SMTPRCPT?
+SMTPRCPT: 0, 0, “[email protected]”, “rcptname_to”
+SMTPRCPT: 1, 0, “[email protected]”, “rcptname_cc”
OK
16.7.5
AT+SMTPSUB E-mail subject
Description
This synchronous command is used to set the subject of e-mail, which is used to construct e-mail header. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current e-mail subject.
Execution command will clear the subject.
NOTE: After an e-mail is sent successfully, the subject will be cleared, if unsuccessfully, it won’t be cleared.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SMTPSUB=?
Read Command
AT+SMTPSUB?
Responses
OK
Responses
+SMTPSUB: <subject>
OK
Write Command Responses
AT+SMTPSUB= <subject> OK
Execution Command
AT+SMTPSUB
Responses
OK
Defined values
<subject>
E-mail subject, string with double quotes, and ASCII text up to 511 characters. <subject> will be present in the header of the e-mail sent by SMTP client in the field: “ Subject: ”. For write command, if the subject contains non-ASCII characters, this parameter should contain a prefix of
{non-ascii}.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+SMTPSUB?
+SMTPSUB: “”
OK
AT+SMTPSUB=”THIS IS A TEST MAIL”
OK
AT+SMTPSUB={non-ascii}”E6B58BE8AF95E982AEE4BBB6”
OK
AT+SMTPSUB?
+SMTPSUB: “THIS IS A TEST MAIL”
OK
16.7.6
AT+SMTPBODY E-mail body
Description
This command is used to set e-mail body, which will be sent to SMTP server with text format.
Read command returns current e-mail body. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Execute command will switch the serial port from command mode to data mode, so TE can enter more ASCII text as e-mail body (up to 5120), and CTRL-Z (ESC) is used to finish (cancel) the input operation and switch the serial port back to command mode.
NOTE: After an e-mail is sent successfully, the body will be cleared, if unsuccessfully, it won’t be cleared. When execute command AT+SMTPBODY, and display “>>”, the prevenient body will be cleared.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SMTPBODY=?
Read Command
AT+SMTPBODY?
Responses
OK
Responses
+SMTPBODY: <body>
OK
Write Command Responses
AT+SMTPBODY= <body> OK
Execution Command
AT+SMTPBODY
Responses
>>
Defined values
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<body>
E-mail body, string with double quotes, and printable ASCII text up to 511 or 5120 characters.
NOTE: In data mode, “BACKSPACE” can be used to cancel an ASCII character.
Examples
AT+SMTPBODY=”THIS IS A TEST MAIL FROM SIMCOM MODULE”
OK
AT+SMTPBODY?
+SMTPBODY: ”THIS IS A TEST MAIL FROM SIMCOM MODULE”
OK
AT+SMTPBODY
>> This is a test mail.
<CTRL-Z>
OK
AT+SMTPBODY?
+SMTPBODY: ”This is a test mail.”
OK
AT+SMTPBODY
>> This is a test mail.
<ESC>
OK
AT+SMTPBODY?
+SMTPBODY: “”
OK
16.7.7
AT+SMTPBCH E-mail body character set
Description
This synchronous command is used to set the body character set of e-mail. If the process sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current e-mail body character set.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SMTPBCH=?
Read Command
AT+SMTPBCH?
Responses
+SMTPBCH: ”CHARSET”
OK
Responses
+SMTPBCH: <charset>
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
AT+SMTPBCH= <charset>
Execution Command
AT+SMTPBCH
Responses
OK
ERROR
Responses
OK
ERROR
Defined values
<charset>
E-mail body character, string with double quotes. By default, it is “utf-8”. The maximum length is
19 bytes.
Examples
AT+SMTPBCH=?
+SMTPBCH: “CHARSET”
OK
AT+SMTPBCH=”gb2312”
OK
AT+SMTPBCH?
+SMTPBCH: “gb2312”
OK
16.7.8
AT+SMTPFILE Select attachment
Description
The synchronous command is used to select file as e-mail attachment. If the process sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current all selected attachments with full path.
Execute command will clear all attachments.
NOTE: After an e-mail is sent successfully, attachment will be cleared, if unsuccessfully, it won’t be cleared. The same file can’t be selected twice.
AT+SMTPFILE=<index> is used to delete the relevant attachments.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SMTPFILE=?
Responses
+SMTPFILE: (list of supported <index> s)
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+SMTPFILE?
Write Command
AT+SMTPFILE=
<index> [, <filename> ]
Execution Command
AT+SMTPFILE
Responses
[+SMTPFILE: <index> , <filename> , <filesize>
[<CR><LF>…]]
OK
Responses
OK
[+SMTP: OVERSIZE]
ERROR
Responses
OK
Defined values
<index>
Index for attachments, from 1 to 10. According to the sequence of <index> , SMTP client will encode and send all attachments.
<filename>
String type with double quotes, the name of a file which is under current directory (refer to file system commands). SMTP client doesn’t allow two attachments with the same file name. For write command, if the file name contains non-ASCII characters, this parameter should contain a prefix of
{non-ascii}.
<filesize>
File size in decimal format. The total size of all attachments can’t exceed 10MB.
Examples
AT+SMTPFILE=1,”file1.txt”
OK
AT+SMTPFILE=1,{non-ascii}”E6B58BE8AF95E99984E4BBB62E6A7067”
OK
AT+SMTPFILE?
+SMTPFILE: 1, “C:/file1.txt”
OK
AT+SMTPFILE=2,”file2.txt”
OK
AT+SMTPFILE?
+SMTPFILE: 1, “C:/file1.txt”
+SMTPFILE: 2, “C:/file2.txt”
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.7.9
AT+SMTPSEND Initiate session and send e-mail
Description
This asynchronous command is used to initiate TCP session with SMTP server and send an e-mail after all mandatory parameters have been set correctly. After SMTP client has connected with specified SMTP server and SMTP client receives an indication that indicates SMTP server is working well, the command will return “+SMTP: OK”, but it doesn’t indicate that the e-mail is already sent successfully.
After the e-mail is sent and the session is closed, an Unsolicited Result Code (URC) will be returned to TE, “+SMTP: SUCCESS” indicates the e-mail is sent successfully, and other URCs indicate a failed result and the session is closed.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SMTPSEND=?
Read Command
AT+SMTPSEND?
Execution Command
AT+SMTPSEND
Responses
OK
Responses
+SMTPSEND: <ongoing>
OK
Responses
OK
+SMTP: OK
+SMTP: <code>
+SMTP: OK
+SMTP: <code>
OK
+SMTP: <code>
ERROR
Defined values
<ongoing>
Whether or not an e-mail is sent in process. If the process of sending an e-mail is ongoing, SMTP client can’t send the e-mail again.
0 – Not ongoing.
1 – Ongoing.
<code>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SUCCESS
ONGOING
PARAM ERROR
SMTP client has sent the e-mail successfully.
The process of sending an e-mail is ongoing.
Mandatory parameter isn’t set (SMTP server, or sender/recipient address)
NETWORK ERROR Invalid SMTP server.
Network is bad for establishing session or sending data to SMTP server.
SERVER ERROR SMTP server released the session.
SMTP server rejects the operation with wrong response.
SMTP server doesn’t give SMTP client a response in time.
AUTH REQUIRED
AUTH ERROR
USER CANCEL
Authentication is required by SMTP server.
SMTP server rejects the session because of bad user name and password combination.
User called AT+SMTPSTOP.
Examples
AT+SMTPSEND?
+SMTPSEND: 0
OK
AT+SMTPSEND
+SMTP: OK
OK
+SMTP: SUCCESS
16.7.10 AT+SMTPSTOP Force to stop sending e-mail
Description
The synchronous command is used to force to stop sending e-mail and close the TCP session while sending an e-mail is ongoing. Otherwise, the command will return “ERROR” directly.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+SMTPSTOP=?
Execution Command
AT+SMTPSTOP
Responses
OK
Responses
OK
ERROR
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+SMTPSEND?
+SMTPSEND: 1
OK
AT+SMTPSTOP
OK
16.8
SMTPS
This chapter supports SMTP / SMTPS two kinds server. The old SMTP only supports SMTP server, and the old SMTP AT commands are for compatibility with previous customers. New customers are recommended to use the commands in this chapter.
16.8.1
AT+CSMTPSSRV Set SMTP server address and port number
Description
This command is used to set SMTP server address and server’s port number. SMTP client will initiate TCP session with the specified server to send an e-mail. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current SMTP server address and port number.
Execution command will clear SMTP server address and set the port number as default value.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSMTPSSRV=?
Read Command
AT+CSMTPSSRV?
Write Command
AT+CSMTPSSRV= <server>
, <port> [, <server_type> ]
Execution Command
AT+CSMTPSSRV
Responses
OK
Responses
+CSMTPSSRV: <server> , <port> , <server_type>
OK
Responses
OK
ERROR
Responses
OK
ERROR
Defined values
<server>
SMTP server address, non empty string with double quotes, mandatory and ASCII text string up to
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
127 characters.
<port>
Port number of SMTP server in decimal format, from 1 to 65535, and default port is 25 for SMTP.
<server_type>
The type of server:
1 – SMTP server.
2 – SMTPS server with SSL3.0/TLS1.0 supported
Examples
AT+CSMTPSSRV="smtp.server.com",425
OK
AT+CSMTPSSRV?
+CSMTPSSRV: "smtp.server.com",425,2
OK
AT+SMTPSRV
OK
AT+SMTPSRV?
+SMTPSRV: "",25,2
OK
16.8.2
AT+CSMTPSAUTH SMTP server authentication
Description
This synchronous command is used to control SMTP authentication during connection with SMTP server. If SMTP server requires authentication while logging in the server, TE must set the authentication control flag and provide user name and password correctly before sending an e-mail.
If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current SMTP server authentication control flag, if the flag is 0, both <user> and <pwd> are empty strings.
Execution Command clears user name and password.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSMTPSAUTH=?
Read Command
AT+CSMTPSAUTH?
Responses
+CSMTPSAUTH: (list of supported <flag> s)
OK
Responses
+CSMTPSAUTH: <flag>, <user>, <pwd>
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
AT+CSMTPSAUTH=
<flag> [, <user> , <pwd> ]
Execution Command
AT+CSMTPSAUTH
Responses
OK
ERROR
Responses
OK
ERROR
Defined values
<flag>
SMTP server authentication control flag, integer type.
0 – SMTP server doesn’t require authentication, factory value.
1 – SMTP server requires authentication.
<user>
User name to be used for SMTP authentication, non empty string with double quotes and up to 127 characters.
<pwd>
Password to be used for SMTP authentication, string with double quotes and up to 127 characters.
NOTE: If <flag> is 0, <user> and <pwd> must be omitted (i.e. only <flag> is present).
Examples
AT+CSMTPSAUTH?
+CSMTPSAUTH: 0, “”, “”
OK
AT+CSMTPSAUTH=1,”username”,”password”
OK
AT+CSMTPSAUTH?
+CSMTPSAUTH: 1, ”username”, ”password”
OK
AT+CSMTPSAUTH
OK
AT+CSMTPSAUTH?
+CSMTPSAUTH: 0, “”, “”
OK
16.8.3
AT+CSMTPSFROM Sender address and name
Description
This synchronous command is used to set sender’s address and name, which are used to construct e-mail header. The sender’s address must be correct if the SMTP server requries, and if the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read command returns current sender’s address and name.
Execution command will clear sender’s address and name.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSMTPSFROM=?
Read Command
AT+CSMTPSFROM?
Write Command
AT+CSMTPSFROM=
<saddr> [, <sname> ]
Execution Command
AT+CSMTPSFROM
Responses
OK
Responses
+CSMTPSFROM: <saddr> , <sname>
OK
Responses
OK
ERROR
Responses
OK
ERROR
Defined values
<saddr>
E-mail sender address (MAIL FROM), non empty string with double quotes, mandatory and ASCII text up to 127 characters. <saddr> will be present in the header of the e-mail sent by SMTP client in the field: “ From: ”.
<sname>
E-mail sender name, string with double quotes, and alphanumeric ASCII text up to 63 characters.
<sname> will be present in the header of the e-mail sent by SMTP client in the field: “ From: ”.
Examples
AT+CSMTPSFROM="[email protected]","sendername"
OK
AT+CSMTPSFROM?
+CSMTPSFROM: "[email protected]", "sendername"
OK
AT+CSMTPSFROM
OK
AT+CSMTPSFROM?
+CSMTPSFROM: "", ""
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.8.4
AT+CSMTPSRCPT Recipient address and name (TO/CC/BCC)
Description
This synchronous command is used to set recipient address/name and kind (TO/CC/BCC). If only the parameter of “kind” is present, the command will clear all recipients of this kind, and if only parameters of “kind” and “index” are present, the command will clear the specified recipient. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current recipient address/name and kind list.
Execution command will clear all recipient information.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSMTPSRCPT=?
Read Command
AT+CSMTPSRCPT?
Write Command
AT+CSMTPSRCPT=
<kind> [, <index>
[, <raddr> [, <rname> ]]]
Execution Command
AT+CSMTPSRCPT
Responses
+CSMTPSRCPT: (list of supported <kind> s), (list of supported
<index> s)
OK
Responses
[+CSMTPSRCPT: <kind> , <index> , <raddr> , <rname>
[<CR><LF>…]]
OK
OK
ERROR
Responses
OK
ERROR
Responses
OK
ERROR
Defined values
<kind>
Recipient kind, the kinds of TO and CC are used to construct e-mail header in the field: “ To: ” or
“ Cc: ”.
0 – TO, normal recipient.
1 – CC, Carbon Copy recipient.
2 – BCC, Blind Carbon Copy recipient.
<index>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Index of the kind of recipient, decimal format, and from 0 to 4.
<raddr>
Recipient address, non empty string with double quotes, and up to 127 characters.
<rname>
Recipient name, string type with double quotes, and up to 63 characters.
Examples
AT+CSMTPSRCPT=0, 0, “[email protected]”, “rcptname_to”
OK
AT+CSMTPSRCPT?
+CSMTPSRCPT: 0, 0, “[email protected]”, “rcptname_to”
OK
AT+CSMTPSRCPT=1, 0, “[email protected]”, “rcptname_cc”
OK
AT+CSMTSPRCPT?
+CSMTPSRCPT: 0, 0, “[email protected]”, “rcptname_to”
+CSMTPSRCPT: 1, 0, “[email protected]”, “rcptname_cc”
OK
16.8.5
AT+CSMTPSSUB E-mail subject
Description
This synchronous command is used to set the subject of e-mail, which is used to construct e-mail header. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current e-mail subject.
Execution command will clear the subject.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSMTPSSUB=?
Read Command
AT+CSMTPSSUB?
Write Command
AT+CSMTPSSUB= <subject
_len> [, <subject_character> ]
Responses
OK
Responses
+CSMTPSSUB: < subject_len >,< subject_character ><CR><LF>
[< subject >]
OK
Responses
>
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Execution Command
AT+CSMTPSSUB
Syntax
Test Command
AT+CSMTPSBODY=?
Read Command
Responses
OK
ERROR
Defined values
<subject>
E-mail subject, string with double quotes, and ASCII text up to 511 characters. <subject> will be present in the header of the e-mail sent by SMTPS client in the field: “ Subject: ”. For write command, it can input any binary data.
<subject_len>
The length of subject content
<subject_character>
The character set of subject. Default is utf-8.
Examples
AT+CSMTPSSUB?
+CSMTPSSUB: 0,“utf-8”
OK
AT+CSMTPSSUB=19, ”utf-8”
> THIS IS A TEST MAIL
OK
AT+CSMTPSSUB?
+CSMTPSSUB: 19, “utf-8”
THIS IS A TEST MAIL
OK
16.8.6
AT+CSMTPSBODY E-mail body
Description
This command is used to set e-mail body, which will be sent to SMTP server with text format.
Read command returns current e-mail body. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly. Execution command clears email body.
SIM PIN References
YES Vendor
Responses
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CSMTPSBODY?
Write Command
AT+CSMTPSBODY= <body
_len>
Execution Command
AT+CSMTPSBODY
+CSMTPSBODY: <body_len> <CR><LF>
[< body >]
OK
Responses
>
OK
Responses
OK
Defined values
<body>
E-mail body, up to 5120 characters.
<body_len>
The length of email body.
Examples
AT+CSMTPSBODY=38
> THIS IS A TEST MAIL FROM SIMCOM MODULE
OK
AT+CSMTPSBODY?
+CSMTPSBODY: 38
THIS IS A TEST MAIL FROM SIMCOM MODULE
OK
16.8.7
AT+CSMTPSBCH E-mail body character set
Description
This synchronous command is used to set the body character set of e-mail. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current e-mail body character set.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSMTPSBCH=?
Read Command
AT+CSMTPSBCH?
Responses
OK
Responses
+CSMTPSBCH: <charset>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
AT+CSMTPSBCH= <charset
>
Execution Command
AT+CSMTPSBCH
OK
Responses
OK
ERROR
Responses
OK
ERROR
Defined values
<charset>
E-mail body character, string with double quotes. By default, it is “utf-8”. The maximum length is
19 bytes.
Examples
AT+CSMTPSBCH=?
OK
AT+CSMTPSBCH=”gb2312”
OK
AT+CSMTPSBCH?
+CSMTPSBCH: “gb2312”
OK
16.8.8
AT+CSMTPSFILE Select attachment
Description
The synchronous command is used to select file as e-mail attachment. If the process of sending an e-mail is ongoing, the command will return “ERROR” directly.
Read command returns current all selected attachments with full path.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSMTPSFILE=?
Read Command
AT+CSMTPSFILE?
Responses
+CSMTPSFILE: (list of supported <index> s)
OK
Responses
[+CSMTPSFILE: <index> , <filename> , <filesize>
[<CR><LF>…]]
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Write Command
AT+CSMTPSFILE=
<index> [, <filename> ]
Execution Command
AT+CSMTPSFILE
Responses
OK
[+CSMTPS: <err> ]
ERROR
Responses
OK
Defined values
<index>
Index for attachments, from 1 to 10. According to the sequence of <index> , SMTP client will encode and send all attachments.
<filename>
String type with double quotes, the name of a file which is under current directory (refer to file system commands). SMTP client doesn’t allow two attachments with the same file name. For write command, if the file name contains non-ASCII characters, this parameter should contain a prefix of
{non-ascii}.
<filesize>
File size in decimal format. The total size of all attachments can’t exceed 10MB.
<err>
The error information.
Examples
AT+CSMTPSFILE=1,”file1.txt”
OK
AT+CSMTPSFILE=1,{non-ascii}”E6B58BE8AF95E99984E4BBB62E6A7067”
OK
AT+CSMTPSFILE?
+CSMTPSFILE: 1, “C:/file1.txt”
OK
AT+CSMTPSFILE=2,”file2.txt”
OK
AT+CSMTPSFILE?
+CSMTPSFILE: 1, “C:/file1.txt”
+CSMTPSFILE: 2, “C:/file2.txt”
OK
16.8.9
AT+CSMTPSSEND Initiate session and send e-mail
Description
This asynchronous command is used to initiate TCP/SSL session with SMTP server and send an
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set e-mail after all mandatory parameters have been set correctly.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSMTPSSEND=?
Execution Command
AT+CSMTPSSEND
Responses
OK
Responses
OK
+CSMTPSSEND: <err>
ERROR
+CSMTPSSEND: <err>
ERROR
Defined values
<err>
The error information. 0 indicates success. Other values indicate failure.
Examples
AT+CSMTPSSEND
OK
+CSMTPSSEND: 0
16.8.10
AT+CSMTPSSTOP Force to stop sending e-mail
Description
The synchronous command is used to force to stop sending e-mail and close the TCP/SSL session while sending an e-mail is ongoing. Otherwise, the command will return “ERROR” directly.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSMTPSSTOP=?
Execution Command
AT+CSMTPSSTOP
Responses
OK
Responses
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3
4
5
6
0
1
2
7
8
ERROR
Examples
AT+CSMTPSSTOP
OK
16.8.11
AT+CSMTPSCLEAN Clean mail content and setting
Description
The synchronous command is used to clean mail content and setting.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSMTPSCLEAN=?
Execution Command
AT+CSMTPSCLEAN
Responses
OK
Responses
OK
ERROR
Examples
AT+CSMTPSCLEAN
OK
16.8.12 Unsolicited SMTPS command <err> Codes
SMTPS operation succeeded
Busy
Over size
Duplicate file
Time out
Transfer failed
Memory error
Invalid parameter
Network error
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
9
10
11
12
255
EFS operation error
SMTP server error
Authentication failure
User cancel
Unknown error
16.9
Common Channel Service
The common channel related AT commands needs the AT+CATR to be set to the used port.
AT+CATR=0 may cause some problem.
16.9.1
AT+CCHSTART Acquire common channel service
Description
This command is used to acquire common channel service.
SIM PIN References
YES Vendor
Syntax
Execute Command
AT+CCHSTART
Responses
OK
+CCHSTART: <err>
+CCHSTART: <err>
OK
ERROR
Defined values
<err>
The result code of the acquiring common channel service. 0 is success. Other values are failure.
Examples
AT+CCHSTART
OK
+CCHSTART: 0
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.9.2
AT+CCHSTOP Stop common channel service
Description
This command is used to stop common channel service.
SIM PIN References
YES Vendor
Syntax
Execute Command
AT+CCHSTOP
Responses
OK
+CCHSTOP: <err>
+CCHSTOP: <err>
OK
ERROR
Defined values
<err>
The result code of the stoping common channel service. 0 is success. Other values are failure.
Examples
AT+CCHSTOP
OK
+CCHSTOP: 0
16.9.3
AT+CCHOPEN Open a channel
Description
This command is used to connect peer using common channel service.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CCHOPEN=?
Write Command
Responses
+CCHOPEN: (0,1), ” ADDRESS”, list of <port> s [,list of
<channel_type> s [,list of <bind_port> s]]
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CCHOPEN= <session_i d> , ” <host> ”, <port> [ <chann el_type> ,[ <bind_port> ]]
OK
+CCHOPEN: <session_id> , <err>
+CCHOPEN: <session_id> , <err>
OK
Open channel successfully in transparent mode:
CONNECT <text>
Open channel failed in transparent mode:
CONNECT FAIL
ERROR
Defined values
<session_id>
The session index to operate. It’s from 0 to 1. In transparent mode, only 0 is valid.
<host>
The host address, maximum length is 256
<port>
The peer port for channel, the range is from 1 to 65535
<channel_type>
The type of channel:
0 – UDP.
1 – TCP client.
2 – SSLv3.0/TLSv1.0 client.
<bind_port>
The local port for channel, the range is from 1 to 65535
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
The result code of the opening common channel. 0 is success. Other values are failure.
Examples
AT+CCHOPEN=0, ”www.myserver.com”,443,2
OK
+CCHOPEN: 0 0
AT+CCHOPEN=0, ”www.myserver.com”,443,1
OK
+CCHOPEN: 0,0
16.9.4
AT+CCHCLOSE Close a channel
Description
This command is used to disconnect from peer.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
YES Vendor
Syntax
Write Command Responses
AT+CCHCLOSE= <session_ id>
OK
+CCHCLOSE: <session_id>,<err>
+CCHCLOSE: <session_id>,<err>
OK
ERROR
Defined values
<session_id>
The session index to operate. It’s from 0 to 1.
<err>
The result code of the closing common channel. 0 is success. Other values are failure.
Examples
AT+CCHCLOSE=0
OK
+CCHCLOSE: 0,0
16.9.5
AT+CCHSEND Send data to peer
Description
This command is used to send data to peer. If the first parameter of AT+CCHSET is set to 1, the +CCHSEND:
<session_id>
,
<err>
will be reported after AT+CCHSEND is finished.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CCHSEND=?
Read Command
AT+CCHSEND?
Write Command
Responses
+CCHSEND: (0,1),(1-2048)
OK
Responses
+CCHSEND: 0, <unsent_len_0>,1,<unsent_len_1>
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+ CCHSEND
= <session_id> , <len>
>
OK
ERROR
Defined values
<session_id>
The session index to operate. It’s from 0 to 1.
<len>
The length of data to send. Its range is from 1 to 2048.
<unsent_len_0>
The data of channel session 0 cached in DS layer which is waiting to be sent.
<unsent_len_1>
The data of channel session 1 cached in DS layer which is waiting to be sent.
Examples
AT+CCHSEND=0, 125
>GET / HTTP/1.1
Host: www.google.com.hk
User-Agent: MAUI htp User Agent
Proxy-Connection: keep-alive
Content-Length: 0
OK
16.9.6
AT+CCHRECV Receive data from the channel
Description
This command is used to receive data from the channel.
SIM PIN References
YES Vendor
Syntax
Read Command
AT+CCHRECV?
Write Command
AT+CCHRECV= <session_i d> [, <max_recv_len> ]
Responses
+CCHRECV: LEN, <cache_len_0>,1,<cache_len_1>
OK
Responses
OK
[+CCHRECV: DATA, <session_id> , <len>
…
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CCHRECV: DATA, <session_id> , <len>
…]
+CCHRECV: <session_id>, <result>
ERROR
Defined values
<session_id>
The session index to operate. It’s from 0 to 1.
<max_recv_len>
Maximum bytes of data to receive in the current AT+CCHRECV calling. 0 means maximum 2048 bytes.
<cache_len_0>
The length of RX data cached for session 0.
<cache_len_1>
The length of RX data cached for session 1.
<result>
The final result of the receiving.
0 – ok
1 – unknown error
2 – busy
3 – server closed
4 – timeout
5 – transfer failed
6 – memory error
7 – invalid parameter
8 – network error
<len>
The length of data followed.
Examples
AT+CCHRECV=1
OK
+CCHRECV: DATA,1,249
HTTP/1.1 200 OK
Content-Type: text/html
Content-Language: zh-CN
Content-Length: 57
Date: Tue, 31 Mar 2009 01:56:05 GMT
Connection: Close
Proxy-Connection: Close
<html>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<header>test</header>
<body>
Test body
</body>
+CCHRECV:1, 0
16.9.7
AT+CCHSET Set the parameter of common channel service
Description
This command is set the parameter of common channel service. It must be called before
AT+CCHSTART.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CCHSET=?
Read Command
AT+CCHSET?
Write Command
AT+ CCHSET
= <report_send_result>[,<rec v_mode>]
Responses
+CCHSET: (0,1),(0,1)
OK
Responses
+CCHSET: <report_send_result>,<recv_mode>
OK
Responses
OK
ERROR
Defined values
<report_send_result>
Whether to report result of CCHSEND:
0 – No.
1 – Yes.
<recv_mode>
The receiving mode:
0 – Output the data to MCU whenever received data.
1 – Module caches the received data and notify MCU with +CCHEVENT: <session_id> ,
RECV EVENT. MCU can use AT+CCHRECV to receive the cached data(manual receiving mode).
Examples
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+CCHSET=1,1
OK
16.9.8
AT+CCHADDR Get the IPv4 address for common channel service
Description
This command is used to get the IPv4 address after calling AT+CCHSTART.
SIM PIN References
YES Vendor
Syntax
Execute Command
AT+ CCHADDR
Responses
+CCHADDR: < ip_address>
OK
ERROR
Defined values
<ip_address>
A string parameter that identifies the IPv4 address of the common channel service when connecting to Packet network.
Examples
AT+CCHADDR
+CCHADDR: 10.71.155.118
OK
16.9.9
AT+CCHMODE Set the mode of common channel service
Description
This command is set the mode of common channel service. This AT command must be called before calling AT+CCHSTART.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CCHMODE=?
Responses
+CCHMODE: (0,1)
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Read Command
AT+CCHMODE?
Write Command
AT+ CCHMODE = <mode>
OK
Responses
+CCHMODE: <mode>
OK
Responses
OK
ERROR
Defined values
<mode>
The mode of common channel service:
0 – Normal.
1 – Transparent mode.
Examples
AT+CCHMODE=1
OK
16.9.10 AT+CCHSTATE Get the state of common channel
Description
This command is used to get the state of common channel.
SIM PIN References
NO Vendor
Syntax
Execute Command
AT+CCHSTATE
Responses
+CCHSTATE: <network_state>,<session0_state>,<session1_state>
OK
ERROR
Defined values
<network_state>
0 – None
1 – Accquired stack
2 – Opening network
3 – Closing network
4 – Opened network
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
3
4
5
6
7
8
9
0
1
2
<session0_state> & <session1_state>
0 – None
1 – Created session
2 – Closing session
3 – Opening session
4 – Opened session
Examples
AT+CCHSTATE
+CCHSTATE: 0,0,0
OK
16.9.11 Unsolicited common channel Codes
Code Description
+CCHEVENT:
<session_id>
In manual receiving mode, when new data of a channel arriving to the module, this unsolicited result code will be reported to
EVENT
MCU.
+CCH_PEER_CLOSED:
<session_id>
The channel is closed by the peer.
16.9.12 Unsolicited common channel command <err> Codes
Operation succeeded
Alerting state(reserved)
Unknown error
Busy
Peer closed
Operation timeout
Transfer failed
Memory error
Invalid parameter
Network error
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.10
SSL Certificate & Key Management
16.10.1
AT+CCERTDOWN Transfer a certificate file to Module
Description
This command is used to transfer a certificate or key file to the module.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CCERTDOWN=?
Write Command
Responses
OK
Responses
AT+CCERTDOWN=“ <filen ame> ”, <len>
>
OK
>
ERROR
ERROR
Defined values
<filename>
The name of the certificate/key file. The file name must have type like “.der” or “.pem”, and the .pem file cannot be protected using password.
<len>
The length of the file data to send.
Examples
AT+CCERTDOWN=”client_key.der”,611
>file content...
OK
16.10.2
AT+CCERTLIST List certificate/key in module
Description
This command is used to list certificate/key files which has already been downloaded to the module.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CCERTLIST=?
Execution Command
AT+CCERTLIST
Responses
OK
Responses
[
<list of files> with “+CCERTLIST:” header
<CR><LF>]
OK
Defined values
<list of files>
The certificate/key files which has been downloaded to the module.
Examples
AT+CCERTLIST=?
OK
AT+CCERTLIST
+CCERTLIST: "ca_cert.der"
+CCERTLIST: "client_cert.der"
+CCERTLIST: "client_key.der"
+CCERTLIST: "server_cert.pem"
+CCERTLIST: "server_key.pem"
OK
16.10.3
AT+CCERTDELE Delete certificate/key in the module
Description
This command is used to delete a certificate/key file in the module.
SIM PIN References
NO Vendor
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Syntax
Test Command
AT+CCERTDELE=?
Write Command
AT+CCERTDELE= <filena me>
Responses
OK
Responses
OK
ERROR
Defined values
<filename>
String with or with double quotes, file name which is relative and already existing.
Examples
AT+CCERTDELE=”server_key.pem”
OK
16.10.4
AT+CSSLCA Set the CA used in the module
Description
This command is used to set the CA used in following SSL operation. The command only can be used after AT+CHTTPSSTART/AT+CCHSTART/AT+CFTPSSTART, and before any SSL open operation.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSSLCA=?
Read Command
AT+CSSLCA?
Write Command
AT+CSSLCA
= <chain_ind ex>
,
<filename>
Responses
OK
Response
(list of +CSSLCA: <chain_index> , <filename> s)
OK
ERROR
Responses
OK
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<chain_index>
The index of CA in the chain. The range is from 0 to 3.
<filename>
The name of the CA file.
Examples
AT+CSSLCA=0, “rootca.der”
OK
AT+CSSLCA=1,”intermediate.der”
OK
16.10.5
AT+CSSLCERT Set the certificate file used in the module
Description
This command is used to set the certificate file used in following SSL operation. The command only can be used after AT+CHTTPSSTART/AT+CCHSTART/AT+CFTPSSTART, and before any
SSL open operation.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSSLCERT=?
Read Command
AT+CSSLCERT?
Write Command
AT+CSSLCERT
= <filenam e>,<ca_chain_index>
Responses
OK
Response
+CSSLCERT: <filename>,<ca_chain_index>
OK
ERROR
Responses
OK
ERROR
Defined values
<ca_chain_index>
The index of CA file in the chain. The range is from 0 to 3. The <filename> certificate file has been signed using this CA file.
<filename>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
The name of the certificate file.
Examples
AT+CSSLCERT=“mycert.der”,0
OK
16.10.6
AT+CSSLKEY Set the key file used in the module
Description
This command is used to set the key file used in following SSL operation. The command only can be used after AT+CHTTPSSTART/AT+CCHSTART/AT+CFTPSSTART, and before any SSL open operation.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSSLKEY=?
Read Command
AT+CSSLKEY?
Write Command
AT+CSSLKEY
= <filename
>
[,
<sll_key_type>
]
Responses
OK
Response
+CSSLKEY: <filename>,<sll_key_type>
OK
ERROR
Responses
OK
ERROR
Defined values
<filename>
The name of the key file.
<sll_key_type>
0 - SSL_KEY_TYPE_RSA
1 - SSL_KEY_TYPE_DSA
Examples
AT+CSSLKEY=“myKEY.der”,0
OK
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
16.10.7
AT+CSSLLOADCK Load certificate/key
Description
This command is used to load the certificate/key files which has been set using
AT+CSSLCA/AT+CSSLCERT/AT+CSSLKEY. The command only can be used after
AT+CHTTPSSTART/AT+CCHSTART/AT+CFTPSSTART, and before any SSL open operation.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSSLLOADCK=?
Execution Command
AT+CSSLLOADCK
Responses
OK
Responses
OK
ERROR
Examples
AT+CSSLLOADCK=?
OK
AT+CSSLLOADCK
OK
SIM5310_ATC_V2.00 10/15/2015
17 AT Commands for Multimedia
17.1
AT+CCMXPLAYWAV Play wav audio file
Description
This command is used to play a wav audio file. It can play wav file during a call or not.
NOTE
Wav file format require mono channel, 8kHz sampling frequency, 16bit sampling size,
128kbps.
SIM PIN References
NO Vendor
Syntax
Test Command Responses
AT+CCMXPLAYWAV=? +CCMXPLAYWAV: (list of supported <play_path> s),(list of supported <repeat> s)
OK
Write Command
AT+CCMXPLAYWAV=
<file_name> , <play_path> [, < repeat> ]
Responses
+WAVSTATE: wav play
OK
Report URC automatically after playing end
+WAVSTATE: wav play stop
ERROR
Defined values
<file_name>
The name of wav audio file.
<play_path>
1 – remote path
2 – local path
<repeat>
This parameter is reserved.
Examples
AT+CCMXPLAYWAV=”test.wav”,2
+WAVSTATE: wav play
SIM5310 AT Command Set
OK
17.2
AT+CCMXSTOPWAV Stop playing wav audio file
Description
This command is used to stop playing wav audio file. Execute this command during wav audio playing.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CCMXSTOPWAV=?
Execution Command
AT+CCMXSTOPWAV
Responses
OK
Responses
[+WAVSTATE: wav play stop]
OK
Examples
AT+CCMXSTOPWAV
+WAVSTATE: wav play stop
OK
17.3
AT+CCMXWAVSTATE Get wav file play state
Description
This command is used to get wav play state.
SIM PIN References
NO Vendor
Syntax
Test Command Responses
AT+CCMXWAVSTATE=? OK
Read Command
AT+CCMXWAVSTATE?
Responses
+CCMXWAVSTATE:
OK
ERROR
<state>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Defined values
<state>
0 – wav play stoped
1 – wav playing
Examples
AT+CCMXWAVSTATE?
+CCMXWAVSTATE: 0
OK
18 AT Commands for LUA Script
18.1
AT+CSCRIPTSTART Start running a LUA script file.
Description
This command is used to start running a LUA script file. The script file must exist in c:\ in the module EFS. This command shouldn’t be used by sio LIB in LUA script files.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSCRIPTSTART=?
Write Command
AT+CSCRIPTSTART=" <fil ename> "[," <reportluaerror> "
]
Responses
+CSCRIPTSTART: ” FILENAME ”
[,
(list of supported < reportluaerror> s)
]
OK
Responses
OK
+CSCRIPT: 0
ERROR
OK
+CSCRIPT: <err>
Defined values
<filename>
The script file name .
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
<reportluaerror>
Whether report the LUA compiling error or running error to TE .
0 – Not report.
1 – Report.
2 – Report, and the script run with debug function supporting.
<err>
The error code of running script.
Examples
AT+CSCRIPTSTART=”mytest.lua”
OK
+CSCRIPT: 0
AT+CSCRIPTSTART=?
+CSCRIPTSTART: "FILENAME"[,(0-2)]
OK
18.2
AT+CSCRIPTSTOP Stop the current running LUA script.
Description
This command is used to stop the current running LUA script. This command shouldn’t be used by sio LIB in LUA script files.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSCRIPTSTOP=?
Read Command
AT+CSCRIPTSTOP?
Execute Command
AT+CSCRIPTSTOP
Responses
OK
Responses
If LUA script is running
+CSCRIPTSTOP: “ <filename> ”
OK
If there is no LUA script running
OK
Responses
OK
ERROR
Defined values
<filename>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
The script file name .
Examples
AT+CSCRIPTSTOP?
+CSCRIPTSTOP: ”mytest.lua”
OK
AT+CSCRIPTSTOP=?
OK
AT+CSCRIPTSTOP
OK
18.3
AT+CSCRIPTCL Compile a LUA script file.
Description
This command is used to compile a LUA script file. The script file must exist in c:\ in the module
EFS. This command shouldn’t be used by sio LIB in LUA script files. If the AT+CSCRIPTPASS is set, the compiled file will be encrypted.
SIM PIN References
NO Vendor
Syntax
Test Command
AT+CSCRIPTCL=?
Write Command
AT+CSCRIPTCL=" <filenam e> "[," <out_filename> "]
Responses
+CSCRIPTCL: <filename> , <out_filename>
OK
Responses
OK
+CSCRIPT: 0
ERROR
OK
+CSCRIPT: <err>
Defined values
<filename>
The script file name .
<out_filename>
The output script file name . If this parameter is empty, the default <out_filename> will be the file name of <filename> with the file extension changed to “.out”.
<err>
The error code of running script.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Examples
AT+CSCRIPTCL=”mytest.lua”
OK
+CSCRIPT: 0
AT+CSCRIPTCL=?
+CSCRIPTCL: “FILENAME”,“OUT_FILENAME”
OK
18.4
AT+CSCRIPTPASS Set the password for +CSCRIPTCL.
Description
This command is used to set the password which will be used for AT+CSCRIPTCL encryption.
SIM PIN References
NO Vendor
Syntax
Write Command
AT+CSCRIPTPASS=" <old_ password> "," <new_passwor d> "
Responses
OK
ERROR
Defined values
<old_password>
The old password . The original password for AT+CSCRIPTCL is empty.
<new_password>
The new password.
Examples
AT+CSCRIPTPASS=””,”12345678”
OK
AT+CSCRIPTPASS=”12345678”,”123456”
OK
18.5
AT+CSCRIPTCMD Send data to the running LUA script.
Description
This command is used to send data to the running LUA script
SIM PIN References
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
NO Vendor
Syntax
Test Command
AT+CSCRIPTCMD=?
Execute Command
AT+CSCRIPTCMD= <cmd1
> [, <cmd2> ]
Responses
+CSCRIPTCMD: CMD1[,CMD2]
OK
Responses
OK
ERROR
Defined values
<cmd1>
An integer value to be sent as the second parameter of EVENT 31 to running LUA script .
<cmd2>
An integer value to be sent as the third parameter of EVENT 31 to running LUA script .
Examples
AT+CSCRIPTCMD=?
+CSCRIPTCMD: CMD1[,CMD2]
OK
AT+CSCRIPTCMD=23,98
OK
18.6
AT+PRINTDIR Set the value of LUA printdir function.
Description
This command is used to set the value of LUA printdir function
SIM PIN References
NO Vendor
Syntax
Test Command
AT+PRINTDIR=?
Read Command
AT+PRINTDIR?
Write Command
Responses
+PRINTDIR: (0,1)
OK
Responses
+PRINTDIR: <mode>
OK
Responses
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
AT+PRINTDIR= <mode> OK
ERROR
Defined values
<mode>
The value of printdir:
0 – print function is disabled.
1 – print function is enabled.
Examples
AT+PRINTDIR=0
OK
AT+PRINTDIR?
+PRINTDIR:0
OK
AT+PRINTDIR=?
+PRINTDIR:(0-1)
OK
18.7
AT+CSCRIPTAUTO Enable/Disable LUA run automatically
Description
This command is used to enable or disable LUA scripts run automatically.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CSCRIPTAUTO=?
Read Command
AT+CSCRIPTAUTO?
Write Command
AT+CSCRIPTAUTO= <state
> ,[ <max_left_times> ]
Responses
OK
Responses
+CSCRIPTAUTO: <state> , <left_times>
OK
Responses
OK
ERROR
Defined values
<state>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Enable or disable LUA scripts run automatically:
0 – disalbe LUA scripts run automatically.
1 – enable LUA scripts run automatically.
<max_left_times>
Maximum times that LUA scripts can run automatically when powering up. If it is 0, it means unlimited times. Default value is 0.
<left_times>
Left times that LUA scripts can run automatically when powering up.
Examples
AT+CSCRIPTAUTO=1
OK
AT+CSCRIPTAUTO?
+CSCRIPTAUTO: 1,UNLIMITED
OK
AT+CSCRIPTAUTO=?
OK
18.8
AT+CPWRONCHK Enable/Disable Power on Check
Description
This command is used to enable or disable module powering on check function. By default, the function is enabled. Each time of powering on, the module starts a check timer of two minutes, if the timer is expired, it will regard the module works correctly. If the module is reset or powered off or it crashes before two minutes, the timer cannot expire, then this time of powering on shall be regards abnormal. If the module continuously works incorrectly(each time it cannot work for over two minutes) for twenty times, it will stop the LUA and EBDAT autorun feature.
SIM PIN References
YES Vendor
Syntax
Test Command
AT+CPWRONCHK=?
Read Command
AT+CPWRONCHK?
Responses
OK
Responses
+CPWRONCHK:
<state> , <check_interval> , <thr_times> , <current_failure_times>
OK
Write Command
AT+CPWRONCHK=
<state
Responses
OK
>[ , <check_interval>[ , <th
ERROR
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
r_times>]]
Defined values
<state>
Enable or disable the checking function:
0 – disalbe checking.
1 – enable checking.
<check_interval>
The checking timer checking interval(minutes).
<thr_times>
The threshold times that the module will be regards as it cannot power on correctly.
<current_failure_times>
The times that the module cannot startup correctly.
Examples
AT+CPWRONCHK=1
OK
AT+CPWRONCHK?
+CPWRONCHK: 1,2,20,1
OK
AT+CPWRONCHK=?
OK
18.9
Unsolicited LUA script codes
Summary of +CSCRIPT Codes
3
4
5
Code of <err> Description
0 Success
1
2
No resource
Failed to open the script file
Failed to run the script file
Failed to compile the script file
Virtual machine is busy
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
19 AT Commands Samples
19.1
SMS commands
Commands and Responses
AT+CMGF=1
OK
Comments
Set SMS system into text mode, as opposed to
PDU mode.
AT+CPMS="SM","SM","SM"
+CPMS: 0,40,0,40,0,40
OK
AT+CNMI=2,1
OK
AT+CMGS=“+861358888xxxx”
>This is a test <Ctrl+Z>
+CMGS:34
OK
+CMTI:“SM”,1
AT+CMGR=1
+CMGR: “REC UNREAD”,
“+86135888xxxx”, ,“08/01/30,
20:40:31+00”
This is a test
OK
AT+CMGR=1
+CMGR: “REC READ”,
“+861358888xxxx”,,“08/01/30 ,
20:40:31+00”
This is a test
OK
AT+CMGS=“+861358888xxxx”
> Test again <Ctrl+Z>
+CMGS:35
OK
+CMTI:“SM”,2
AT+CMGL=“ALL”
+CMGL: 1, “REC READ”, “+861358888xxxx”, ,
“08/01/30,20:40:31+00”
This is a test
Select memory storages.
Set new message indications to TE.
Set new message indications to TE.
Unsolicited notification of the SMS arriving.
Read SMS message that has just arrived.
NOTE: The number should be the same as that given in the +CMTI notification.
Reading the message again changes the status to “READ” from “UNREAD”.
Send another SMS to myself.
Unsolicited notification of the SMS arriving.
Listing all SMS messages.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CMGL: 2, “REC UNREAD”,””, “+861358888xx xx”, , “08/01/30,20:45:12+00”
Test again
OK
AT+CMGD=1
OK
Delete an SMS message.
AT+CMGL=“ALL”
+CMGL: 2,“REC READ”,“+861358888xxxx”,
“08/01/30,20:45:12+00”
Test again
OK
List all SMS messages to show message has been deleted.
19.2
File transmission flow
The Module supports to transmit files from the Module to PC host and from PC host to the Module over Xmodem protocol. During the process of transmission, it can not emit any AT commands to do other things.
19.2.1
File transmission to PC host
Step1. Select file for transmission to PC host
After HyperTerminal is OK for emitting AT commands, it must select a file by one of following methods:
① . Select directory as current directory by AT+FSCD , and then select file with parameter <dir_type> of AT+CTXFILE is 0 or omitted. [Figure 17-1]
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Figure 17-1 Select file for transmission
② . Select the file directly with subparameter <dir_type> of AT+CTXFILE is not 0 and not omitted; this method is a shortcut method for limited directories. [Figure 17-2]
Figure 17-2 Select file directly for transmission
Step2. Open “Receive File” dialog box
After select transmitted file successfully, use “Transfer>Receive File…” menu to open “Receive File” dialog box in HyperTerminal. [Figure 17-3]
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Figure 17-3 Open “Receive File” dialog box
Step3. Set storage place and receiving protocol
In “Receive File” dialog box, set the storage place in PC host where file transmitted is saved in text box, and select receiving protocol in combo box.
Then click “Receive” button to open “Receive Filename” dialog box. [Figure 17-4]
NOTE: The receiving protocol must be “Xmodem” protocol.
Step4. Set file name
Figure 17-4 Storage place and receiving potocol
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
In “Receive Filename” dialog box, input file name in “Filename” text box. And then click “OK” button to start transmitting file. [Figure 17-5]
Figure 17-5 Set file name
Step5. Transmit the file
After start file transmission, it can’t emit any AT commands untill transmission stops. In “Xmodem file receive” dialog box, it will display the process of transmission. [Figure 17-6]
Figure 17-6 Xmodem file receive
If the transmission cancelled, HyperTerminal will prompt “Transfer cancelled by user”. [Figure 17-7]
Figure 17-7 Cancel transmission
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
After transmission successfully, the receiving dialog box is closed and it can emit AT commands in
HyperTerminal. [Figure 17-8]
Figure 17-8 Transmission successfully
19.2.2
File received from PC host
Step1. Set file name and storage place
Firstly, it must set file name and storage place in file system of module by one of following methods:
① . Select directory as current directory by AT+FSCD , and then set file name and storage place as current directory with parameter <dir_type > of AT+CRXFILE is 0 or omitted. [Figure 17-9]
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Figure 17-9 Set file name and storage place
② . Set storage place directly with parameter <dir_type> of AT+CTXFILE is not 0 and not omitted; this method is a shortcut method for limited directories.
Step2. Open “Send File” dialog box
After set file name and storage place successfully, use “Transfer>Send File…” menu to open “Send
File” dialog box in HyperTerminal. [Figure 17-10]
Figure 17-10 Open “Send File” dialog box
Step3. Select file and transmitting protocol
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
In “Send File” dialog box, select the file to be transmitted in text box, and select the transmitting protocol in combo box. Then click “Send” button to start transmission. [Figure 17-11]
NOTE: The transmitting protocol must be “Xmodem” protocol.
Figure 17-11 Select file and protocol
Step4. File transmission
After start file transmission, it can’t emit any AT commands utill transmission stops. In “Xmodem file send” dialog box, it will display the process of transmission. [Figure 17-12]
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Figure 17-12 The process of file transmission
If the transmission canceled , HyperTerminal will prompt “Transfer cancelled by user”.
NOTE: There may be some characters reported which denote interactions between module and PC host.
19.3
MMS commands
Set the parameters
AT+CMMSCURL=”mmsc.monternet.com”
OK
AT+CMMSPROTO=1,”10.0.0.172”,80
OK
AT+CMMSSENDCFG=6,3,0,0,2,4
OK
Send MMS
AT+CGSOCKCONT=1,”IP”,”cmwap”
OK
AT+CMMSEDIT=1
OK
AT+CMMSDOWN=”TITLE”,10
>Test title
OK
AT+CMMSDOWN=”FILE”,3,” 1.jpg”
OK
AT+CMMSDOWN=”TEXT”,120,”t1.txt”
>My test content….(file content, 120 bytes)
OK
AT+CMMSRECP=”13918181818”
OK
AT+CMMSRECP=” [email protected]
”
OK
AT+CMMSCC=”15013231222”
Comments
Set the MMS center URL without “http://”
Use http protocol to send MMS and set the IP address and port of MMS proxy to
“10.0.0.172” and 80
Set the parameter of MMS to send. This is unnecessary to set.
Comments
Set the PDP context profile.
Set the edit mode to 1.
Set the title of MMS to “Test title”.
Add the “1.jpg” in UE to the MMS body.
Add a text file named “t1.txt” with length of
120 bytes.
Add a recipient of “ 13918181818”
Add a recipient of [email protected]
Add a copy recipient of ”15013231222”
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
OK
AT+CMMSSAVE=1
+CMMSSAVE: 1
OK
AT+CMMSSEND=”13318882322”
OK
+CMMSSEND:0
Receive MMS
Save the MMS to mail box of index 1.
Send the MMS including new recipient ”13318882322”
After MMS is sent successfully. This command indicates success of sending. If failed, +CME ERROR:<err> will be reported.
Description
+WAP_PUSH_MMS:
"15001844675","RROpJGJVyjeA","http://211.136
.112.84/RROpJGJVyjeA"
,"09/03/17,17:14:41+32",0,13338
AT+CGSOCKCONT=1,”IP”,”cmwap”
Receiving a new MMS notification.
Set the PDP context profile.
OK
AT+CMMSEDIT=0
OK
Set the mms edit mode to 0.
AT+CMMSRECV="http://211.136.112.84/RROpJ
GJVyjeA"
OK
+CMMSRECV:0
AT+CMMSSAVE=0
+CMMSSAVE: 0
OK
Receive MMS using the location contained in
+WAP_PUSH_MMS indication.
After MMS is received successfully, this command indicates success of receiving. If failed, +CME ERROR:<err> will be reported.
If receiving successfully, save it to mail box.
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
20 Appendixes
20.1
Verbose code and numeric code
Verbose result code Numeric (V0 set) Description
OK 0 Command executed, no errors, Wake up after reset
CONNECT 1
RING 2 Ring
NO CARRIER 3 Link not established or disconnected
ERROR
NO DIALTONE
BUSY
NO ANSWER
4
6
7
8
Invalid command or command line too long
No dial tone, dialing impossible, wrong mode
Remote station busy
Connection completion timeout
20.2
Response string of AT+CEER
100
101
102
103
104
105
106
29
45
46
47
48
29
34
35
36
38
Number
CS internal cause
0
21
25
27
Response string
Phone is offline
No service available
Network release, no reason given
Received incoming call
Client ended call
UIM not present
Access attempt already in progress
Access failure, unknown source
Concur service not supported by network
No response received from network
GPS call ended for user call
SMS call ended for user call
Data call ended for emergency call
Rejected during redirect or handoff
Lower-layer ended call
Call origination request failed
Client rejected incoming call
Client rejected setup indication
Network ended call
No funds available
No service available
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
57
58
63
65
68
44
47
49
50
55
69
70
79
34
38
41
42
43
27
28
29
30
31
18
19
21
22
26
3
6
8
16
17
108
109
301
302
303
304
305
CS network cause
1
Full service not available
Maximum packet calls exceeded
Video connection lost
Video call setup failure
Video protocol closed after setup
Video protocol setup failure
Internal error
Unassigned/unallocated number
No route to destination
Channel unacceptable
Operator determined barring
Normal call clearing
User busy
No user responding
User alerting, no answer
Call rejected
Number changed
Non selected user clearing
Destination out of order
Invalid/incomplete number
Facility rejected
Response to Status Enquiry
Normal, unspecified
No circuit/channel available
Network out of order
Temporary failure
Switching equipment congestion
Access information discarded
Requested circuit/channel not available
Resources unavailable, unspecified
Quality of service unavailable
Requested facility not subscribed
Incoming calls barred within the CUG
Bearer capability not authorized
Bearer capability not available
Service/option not available
Bearer service not implemented
ACM >= ACMmax
Requested facility not implemented
Only RDI bearer is available
Service/option not implemented
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
23
32
33
34
38
16
17
20
21
22
40
95
96
11
12
13
14
15
6
7
8
9
10
96
97
98
99
100
81
87
88
91
95
101
102
111
117
CS network reject
2
3
4
5
Invalid transaction identifier value
User not member of CUG
Incompatible destination
Invalid transit network selection
Semantically incorrect message
Invalid mandatory information
Message non-existent/not implemented
Message type not compatible with state
IE non-existent/not implemented
Conditional IE error
Message not compatible with state
Recovery on timer expiry
Protocol error, unspecified
Interworking, unspecified
IMSI unknown in HLR
Illegal MS
IMSI unknown in VLR
IMEI not accepted
Illegal ME
GPRS services not allowed
GPRS & non GPRS services not allowed
MS identity cannot be derived
Implicitly detached
PLMN not allowed
Location Area not allowed
Roaming not allowed
GPRS services not allowed in PLMN
No Suitable Cells In Location Area
MSC temporarily not reachable
Network failure
MAC failure
Synch failure
Congestion
GSM authentication unacceptable
Service option not supported
Requested service option not subscribed
Service option temporarily out of orde
Call cannot be identified
No PDP context activated
Semantically incorrect message
Invalid mandatory information
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
172
173
174
175
176
167
168
169
170
171
162
163
164
165
166
97
98
99
101
161
0
1
2
3
4
177
178
179
PS internal cause lookup
10
11
12
13
14
5
6
7
8
9
PS network cause
25
Message type non-existent
Message type not compatible with state
Information element non-existent
Message not compatible with state
RR release indication
RR random access failure
RRC release indication
RRC close session indication
RRC open session failure
Low level failure
Low level failure no redial allowed
Invalid SIM
No service
Timer T3230 expired
No cell available
Wrong state
Access class blocked
Abort message received
Other cause
Timer T303 expired
No resources
Release pending
Invalid user data
Invalid connection identifier
Invalid NSAPI
Invalid Primary NSAPI
Invalid field
SNDCP failure
RAB setup failure
No GPRS context
PDP establish timeout
PDP activate timeout
PDP modify timeout
PDP inactive max timeout
PDP lowerlayer error
PDP duplicate
Access technology change
PDP unknown reason
LLC or SNDCP failure
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
41
42
43
44
45
36
37
38
39
40
31
32
33
34
35
26
27
28
29
30
98
99
100
101
111
46
81
95
96
97
20.3
Summary of CME ERROR codes
Description
This result code is similar to the regular ERROR result code. The format of <err> can be either numeric or verbose string, by setting AT+CMEE command.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Insufficient resources
Missing or unknown APN
Unknown PDP address or PDP type
User Aauthentication failed
Activation rejected by GGSN
Activation rejected, unspecified
Service option not supported
Requested service option not subscribed
Service option temporarily out of order
NSAPI already used (not sent)
Regular deactivation
QoS not accepted
Network failure
Reactivation required
Feature not supported
Semantic error in the TFT operation
Syntactical error in the TFT operation
Unknown PDP context
PDP context without TFT already activated
Semantic errors in packet filter
Syntactical errors in packet filter
Invalid transaction identifier
Semantically incorrect message
Invalid mandatory information
Message non-existent/not implemented
Message type not compatible with state
IE non-existent/not implemented
Conditional IE error
Message not compatible with state
Protocol error, unspecified
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
+CME ERROR: <err>
Defined values
<err>
Values (numeric format followed by verbose format):
1 no connection to phone
2 phone adaptor link reserved
3 operation not allowed
4 operation not supported
5 PH-SIM PIN required
6 PH-FSIM PIN required
7 PH-FSIM PUK required
10 SIM not inserted
11 SIM PIN required
12 SIM PUK required
13 SIM
14 SIM
15 SIM
16 incorrect
17 SIM PIN2 required
18 SIM PUK2 required
20 memory
21 invalid
22 not
23 memory
24 text string too long
25 invalid characters in text string
26 dial string too long
27 invalid characters in dial string
30 no service
31 network
32 network not allowed - emergency calls only
40 network personalization PIN required
41 network personalization PUK required
42 network subset personalization PIN required
43 network subset personalization PUK required
44 service provider personalization PIN required
45 service provider personalization PUK required
46 corporate personalization PIN required
47 corporate personalization PUK required
100 Unknown
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
103 Illegal MESSAGE
106 Illegal ME
107 GPRS services not allowed
111 PLMN not allowed
112 Location area not allowed
113 Roaming not allowed in this location area
132 service option not supported
133 requested service option not subscribed
134 service option temporarily out of order
148 unspecified GPRS error
149 PDP authentication failure
150 invalid mobile class
257 network rejected request
258 retry operation
259 invalid deflected to number
260 deflected to own number
261 unknown subscriber
262 service not available
263 unknown class specified
264 unknown network message
273 minimum TFTS per PDP address violated
274 TFT precedence index not unique
275 invalid parameter combination
“CME ERROR” codes of MMS:
170 Unknown error for mms
171 MMS task is busy now
172 The mms data is over size
173 The operation is overtime
174 There is no mms receiver
175 The storage for address is full
176 Not find the address
177 Invalid parameter
178 Failed to read mss
179 There is not a mms push message
180 Memory error
181 Invalid file format
182 The mms storage is full
183 The box is empty
184 Failed to save mms
185 It’s busy editing mms now
186 It’s not allowed to edit now
187 No content in the buffer
188 Failed to receive mms
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
189 Invalid mms pdu
190 Network error
191 Failed to read file
192 None
“CME ERROR” codes of FTP:
201
202
203
204
210
211
212
213
214
205
206
207
208
209
Unknown error for FTP
FTP task is busy
Failed to resolve server address
FTP timeout
Failed to read file
Failed to write file
It’s not allowed in current state
Failed to login
Failed to logout
Failed to transfer data
FTP command rejected by server
Memory error
Invalid parameter
Network error
Examples
AT+CPIN="1234","1234"
+CME ERROR: incorrect password
20.4
Summary of CMS ERROR codes
Description
Final result code +CMS ERROR: <err> indicates an error related to mobile equipment or network.
The operation is similar to ERROR result code. None of the following commands in the same command line is executed. Neither ERROR nor OK result code shall be returned. ERROR is returned normally when error is related to syntax or invalid parameters. The format of <err> can be either numeric or verbose. This is set with command AT+CMEE .
SIM PIN References
--- 3GPP TS 27.005
Syntax
+CMS ERROR: <err>
Defined values
<err>
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
300 ME failure
301 SMS service of ME reserved
302 Operation not allowed
303 Operation not supported
304 Invalid PDU mode parameter
305 Invalid text mode parameter
310 SIM not inserted
311 SIM PIN required
312 PH-SIM PIN required
313 SIM failure
314 SIM busy
315 SIM wrong
316 SIM PUK required
317 SIM PIN2 required
318 SIM PUK2 required
320 Memory failure
321 Invalid memory index
322 Memory full
330 SMSC address unknown
331 no network service
332 Network timeout
340 NO +CNMA ACK EXPECTED
341 Buffer overflow
342 SMS size more than expected
500 unknown error
Examples
AT+CMGS=02112345678
+CMS ERROR: 304
SIM5310_ATC_V2.00 10/15/2015
SIM5310 AT Command Set
Contact us
Shanghai SIMCom Wireless Solutions Ltd.
Add: Building A, SIM Technology Building, No.633, Jinzhong Road, Changning District
200335
Tel: +86 21 3252 3300
Fax: +86 21 3252 3301
URL:
http:/
www.sim.com/wm
/
SIM5310_ATC_V2.00 10/15/2015
Download
Advertisement
Key features
Quad band GSM/GPRS/EDGE and Dual band UMTS mode.
Supports GPRS multi-slot class 12 and EDGE multi-slot class 12.
Comprehensive AT command set.
USB2.0 interface, audio interface, abundant interfaces (UART, GPIO and I2C).
Rich functionalities (e.g. RTC, PWM, ADC and Watchdog).
Compact M2M applications.
Frequently asked questions
Use command AT+ICF.
Use command ATE.
Use command ATO.
Use command AT+IFC