Schneider Electric TSX 57/PCX 57 Processors, Implementation User Guide
PDF
Document
Publicitate
Publicitate
Modicon Premium PLCs using PL7 Software TSX 57/PCX 57 Processors Implementation Manual Volume 1 35011052.06 07/2008 eng www.schneider-electric.com 2 35011052.06 07/2008 Document Set Document Set At a Glance This documentation is made up of 5 Volumes: Volume 1 z Racks/Supplies/Processors z Implementation/Diagnostics/Maintenance z Standards and operating conditions z Process supply z Volume 2 z Discrete interfaces z Safety z Volume 3 z Counting z Movement commands z Volume 4 z Communication z Network and bus interfaces z Volume 5 z Analog z Weighing z 35011052.06 07/2008 3 Document Set 4 35011052.06 07/2008 Table of Contents Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 About the Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Part I Premium and Atrium PLC stations . . . . . . . . . . . . . . . . . 17 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Chapter 1 Introduction to Premium and Atrium PLC stations . . . . . . . . . 19 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 TSX P57 PLC station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 PCX 57 PLC station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Chapter 2 General introduction to the components of a PLC station. . . 23 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 General Introduction to TSX P57 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 General introduction to PCX 57 processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 General introduction to TSX RKY racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 General introduction to TSX PSY power supply modules . . . . . . . . . . . . . . . . . . 28 General introduction to Process and AS-i TSX SUP and TSX 1021/1051 power supply modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 General introduction to the TSX REY bus X extension module . . . . . . . . . . . . . 31 General introduction to TSX DEY/DSY/DMY input/output modules . . . . . . . . . . 32 General introduction to TSX CTY/CCY counting modules . . . . . . . . . . . . . . . . . 34 Introduction to TSX CAY axis control modules . . . . . . . . . . . . . . . . . . . . . . . . . . 35 General introduction to TSX CFY step by step control modules . . . . . . . . . . . . . 37 General introduction to TSX SCY/ETY communication . . . . . . . . . . . . . . . . . . . 38 General introduction to the AS-i bus interface module: TSX SAY. . . . . . . . . . . . 43 General introduction to the TSX ISPY weighing module. . . . . . . . . . . . . . . . . . . 44 General introduction to the TSX FAN ventilation module . . . . . . . . . . . . . . . . . . 45 General introduction to the TSX PAY emergency stop monitoring module. . . . . 46 Chapter 3 General introduction to the different configurations of a PLC station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Different types of Premium PLC Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Different types of PLC stations with Atrium processors. . . . . . . . . . . . . . . . . . . . 51 35011052.06 07/2008 5 Chapter 4 Operating Standards and Conditions . . . . . . . . . . . . . . . . . . . 55 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Standards and Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Operating conditions and environmental conditions to be avoided . . . . . . . . . . . 57 Premium PLC protection processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Part II TSX RKY.. standard and extendable racks . . . . . . . . . . . 65 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Chapter 5 Introduction to TSX RKY .. standard/extendable racks.. . . . . 67 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Standard and extendable TSX RKY racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Standard rack: description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Extendable rack: description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Chapter 6 TSX RKY.. standard and extendable racks : installation/ mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Installing Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 mounting and fixing racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Connection of the ground to a TSX RKY rack . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Chapter 7 TSX RKY.. standard and extendable racks: functions . . . . . . 85 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Building a PLC station with Premium processor . . . . . . . . . . . . . . . . . . . . . . . . . 86 Building a PLC station with Atrium processor . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 PLC station rack addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 The principle of addressing two racks at the same address . . . . . . . . . . . . . . . . 93 Module addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Installing power supplies, processors and other modules . . . . . . . . . . . . . . . . . . 96 Chapter 8 TSX RKY Racks: accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 99 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TSX CBY..0K bus X extension cable (II ≥ 02) . . . . . . . . . . . . . . . . . . . . . . . . . . 100 TSX CBY 1000 bus X extension cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Line terminator TSX TLYEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Positioning of line terminators on a station using a Premium processor . . . . . . 106 Positioning of line termination on a station using a Atrium processor . . . . . . . . 107 TSX RKA 02 protective cover for unoccupied positions . . . . . . . . . . . . . . . . . . 108 Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Compatibility with the Installed Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Chapter 9 Ventilation module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 Ventilation module: general introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Ventilation module: physical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 6 35011052.06 07/2008 Ventilation module: dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Ventilation module: mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 Rules for installing racks fitted with ventilation modules . . . . . . . . . . . . . . . . . . 120 Ventilation Module: Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Ventilation module: characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Chapter 10 X-Bus extension module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Bus X extension module: introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 Rack Extender Module: physical description. . . . . . . . . . . . . . . . . . . . . . . . . . . 128 Bus X extension module: installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Bus X extension module: configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 Bus X extension module: maximum distances according to module type. . . . . 134 Bus X extension modules: connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Bus X extension module: diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 Topology of a PLC station with extension module . . . . . . . . . . . . . . . . . . . . . . 142 Managing a power supply module fitted with an bus X extension module . . . . 144 Part III TSX P57/TSX H57 Premium processors. . . . . . . . . . . . 145 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Chapter 11 TSX P57/TSX H57 processors: introduction . . . . . . . . . . . . . 147 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 General Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 Physical Description of TSX P57 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . 150 Real-time clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Chapter 12 TSX P57/TSX H57 processors: installation . . . . . . . . . . . . . . 157 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Positioning of the processor module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 How to mount processor modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 Mounting/Removing a PCMCIA Memory Extension Card on a TSX P57 Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 Processing on Insertion/Extraction of a PCMCIA Memory Card on a Premium PLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 Standard and Backup Memory Cards for PLCs . . . . . . . . . . . . . . . . . . . . . . . . 168 Application + Files Type Memory Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 File Type Memory Card: TSX MRP F 004M Replaces Card TSX MRP DS 2048 P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 Correspondence Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 Chapter 13 TSX P57/TSX H57 processors: diagnostics . . . . . . . . . . . . . . 177 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 Viewing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 Precautions to be taken when replacing a TSX P57/TSX H57 processor. . . . . 181 Changing the RAM memory backup battery on TSX P57 . . . . . . . . . . . . . . . . . 182 35011052.06 07/2008 7 Changing the Battery of a RAM Memory PCMCIA Card on the TSX P57 . . . . . 185 Changing the Battery of a TSX MRP DS 2048 P RAM Memory Card . . . . . . . . 187 Changing the Batteries of a PCMCIA Memory Card . . . . . . . . . . . . . . . . . . . . . 189 Battery Lifetimes for the PCMCIA Memory Card . . . . . . . . . . . . . . . . . . . . . . . . 193 What happens after you press the processor RESET button . . . . . . . . . . . . . . 204 Finding errors using processor state LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 Non blocking errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 Blocking errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Processor or system errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 Chapter 14 TSX P57 103 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 General characteristics of TSX P 57 103 processors . . . . . . . . . . . . . . . . . . . . 211 Chapter 15 TSX P57 153 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 General characteristics of TSX P57 153 processors . . . . . . . . . . . . . . . . . . . . . 213 Chapter 16 TSX P57 203 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 General characteristics of TSX P57 203 processors . . . . . . . . . . . . . . . . . . . . . 215 Chapter 17 TSX P57 253 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 General characteristics of TSX P57 253 processors . . . . . . . . . . . . . . . . . . . . . 217 Chapter 18 TSX P57 2623 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 TSX P57 2623 Processors: General Characteristics . . . . . . . . . . . . . . . . . . . . . 219 Chapter 19 TSX P57 2823 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 TSX P57 2823 Processors: General Characteristics . . . . . . . . . . . . . . . . . . . . . 223 Chapter 20 TSX P57 303 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 General characteristics of TSX P57 303 processors . . . . . . . . . . . . . . . . . . . . . 227 Chapter 21 TSX P57 303A processor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 General characteristics of TSX P57 303A processors. . . . . . . . . . . . . . . . . . . . 229 Chapter 22 TSX P57 353 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 General characteristics of TSX P57 353 processors . . . . . . . . . . . . . . . . . . . . . 233 Chapter 23 TSX P57 353A processor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 General characteristics of TSX P57 353A processors. . . . . . . . . . . . . . . . . . . . 235 Chapter 24 TSX P57 353LA Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . 239 General Characteristics of TSX P57 353LA Processors . . . . . . . . . . . . . . . . . . 239 Chapter 25 TSX P57 3623 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 TSX P57 3623 Processors: General Characteristics . . . . . . . . . . . . . . . . . . . . . 243 Chapter 26 TSX P57 3623A processor. . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 TSX P57 3623A Processors: General Characteristics. . . . . . . . . . . . . . . . . . . . 247 8 35011052.06 07/2008 Chapter 27 TSX P57 453 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251 General characteristics of TSX P57 453 processors. . . . . . . . . . . . . . . . . . . . . 251 Chapter 28 TSX P57 453A processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253 General characteristics of TSX P57 453A processors . . . . . . . . . . . . . . . . . . . 253 Chapter 29 TSX P57 4823 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 TSX P57 4823 Processors: General Characteristics . . . . . . . . . . . . . . . . . . . . 257 Chapter 30 TSX P57 4823A processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 TSX P57 4823A Processors: General Characteristics . . . . . . . . . . . . . . . . . . . 261 Chapter 31 Premium TSX P57/TSX H57 processor: general characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265 Electrical Characteristics of TSX P57 Processors. . . . . . . . . . . . . . . . . . . . . . . 266 Configuration of Premium PL7 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 Devices which can be connected to or built into the processor. . . . . . . . . . . . . 269 Defining and counting application-specific channels. . . . . . . . . . . . . . . . . . . . . 270 Chapter 32 Processor performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271 MAST task cycle time: introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 MAST Task Cycle Time: Program Processing Ppt . . . . . . . . . . . . . . . . . . . . . . 273 MAST Task Cycle Time: Input/Output Internal Processing . . . . . . . . . . . . . . . . 275 Example of the calculation of cycle times of a MAST task under the following conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279 FAST Task Cycle Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281 Event Response Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 Part IV Atrium PCX 57 processors . . . . . . . . . . . . . . . . . . . . . . 283 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 Chapter 33 PCX 57 Processors: introduction . . . . . . . . . . . . . . . . . . . . . . 285 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285 General introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286 Physical description of PCX 57 processors. . . . . . . . . . . . . . . . . . . . . . . . . . . . 288 Real-time clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 Dimensions of PCX 57 processor cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 The different components of a PCX 57 card . . . . . . . . . . . . . . . . . . . . . . . . . . . 292 Chapter 34 PCX 57 Processors: installation . . . . . . . . . . . . . . . . . . . . . . . 295 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295 Precautions to be taken during installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296 Physical installation of the PCX 57 processor in the PC . . . . . . . . . . . . . . . . . . 297 Logical installation of the PCX 57 processor on the bus X . . . . . . . . . . . . . . . . 298 Operations to be carried out before installation. . . . . . . . . . . . . . . . . . . . . . . . . 301 35011052.06 07/2008 9 How to configure the PCX 57 processor address on the bus X. . . . . . . . . . . . . 302 How to configure the processor’s standard I/O address on the ISA bus . . . . . . 304 How to install the PCX 57 processor card in the PC . . . . . . . . . . . . . . . . . . . . . 308 Integrating a PCX 57 processor into an bus X section . . . . . . . . . . . . . . . . . . . 310 How to install/remove the memory extension card on the PCX 57 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313 Processing on insertion/extraction of a PCMCIA memory card on a PCX 57 PLC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314 Memory cards for PCX 57 processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315 Precautions to be taken when replacing a PCX 57 processor. . . . . . . . . . . . . . 316 Chapter 35 PCX 57 processors: Diagnostics . . . . . . . . . . . . . . . . . . . . . . 317 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 Description of PCX 57 processor LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318 Changing the PCX 57 RAM memory backup battery. . . . . . . . . . . . . . . . . . . . . 320 Changing the PCX 57 RAM memory PCMCIA card battery . . . . . . . . . . . . . . . 323 What happens after you press the processor RESET button . . . . . . . . . . . . . . 325 How the PCX 57 behaves after an action on the PC . . . . . . . . . . . . . . . . . . . . . 326 Finding errors via the processor status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . 327 Chapter 36 PCX 57 203 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329 General characteristics of the PCX 57 203 processor . . . . . . . . . . . . . . . . . . . . 329 Chapter 37 PCX 57 353 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331 General characteristics of the PCX 57 353 processor . . . . . . . . . . . . . . . . . . . . 331 Chapter 38 Atrium PCX 57 CPU: general characteristics . . . . . . . . . . . . 333 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333 Electrical characteristics of PCX 57 processors . . . . . . . . . . . . . . . . . . . . . . . . 334 Characteristics of Atrium PL7 processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335 Devices which can be connected to or built into the processor . . . . . . . . . . . . . 336 Defining and Counting Application-specific channels . . . . . . . . . . . . . . . . . . . . 337 Processor performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338 Part V TSX PSY supply modules . . . . . . . . . . . . . . . . . . . . . . . . 339 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339 Chapter 39 TSX PSY… supply modules: introduction. . . . . . . . . . . . . . . 341 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341 General introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342 Supply modules: description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344 Chapter 40 TSX PSY … supply modules: installation . . . . . . . . . . . . . . . 347 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347 Installation/mounting TSX PSY … supply modules . . . . . . . . . . . . . . . . . . . . . . 348 Rules for connecting TSX PSY supply modules . . . . . . . . . . . . . . . . . . . . . . . 349 Connecting alternating current power supply modules . . . . . . . . . . . . . . . . . . . 352 10 35011052.06 07/2008 Connecting direct current power supply modules from a floating 24 or 48 VDC direct current network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354 Connecting direct current power supply modules from an alternating current network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 356 Sensor and pre-actuator power supply servo control . . . . . . . . . . . . . . . . . . . . 362 Definition of protection devices at the start of a line . . . . . . . . . . . . . . . . . . . . . 365 Chapter 41 TSX PSY … supply modules: diagnostics . . . . . . . . . . . . . . . 367 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367 Display on TSX PSY supply modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368 Back-up battery on TSX PSY ... power supply modules . . . . . . . . . . . . . . . . . . 370 Loss of power to rack other than rack 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372 What happens after pressing the RESET button on a power supply module . . 373 Chapter 42 TSX PSY … supply modules : auxiliary functions. . . . . . . . . 375 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375 Alarm relay on TSX PSY supply modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376 Characteristics of the alarm relay contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379 Chapter 43 TSX PSY power supply modules: breakdown of power consumption and power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381 Breakdown of power consumption for selection of the power supply module . 382 Processor consumption breakdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384 I/O module consumption breakdown. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385 Consumption breakdown of analog/counting/movement control modules . . . . 387 Consumption breakdown of communication modules. . . . . . . . . . . . . . . . . . . . 388 Consumption breakdown (other modules) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390 Chapter 44 TSX PSY 2600 power supply module . . . . . . . . . . . . . . . . . . . 391 Characteristics of the TSX PSY 2600 power supply module . . . . . . . . . . . . . . 391 Chapter 45 TSX PSY 5500 power supply module . . . . . . . . . . . . . . . . . . . 393 Characteristics of the TSX PSY 5500 power supply module . . . . . . . . . . . . . . 393 Chapter 46 TSX PSY 8500 power supply module . . . . . . . . . . . . . . . . . . . 395 Characteristics of the TSX PSY 8500 power supply module . . . . . . . . . . . . . . 395 Chapter 47 TSX PSY 1610 power supply module . . . . . . . . . . . . . . . . . . . 397 Characteristics of the TSX PSY 1610 power supply module . . . . . . . . . . . . . . 397 Chapter 48 TSX PSY 3610 power supply module . . . . . . . . . . . . . . . . . . . 399 Characteristics of the TSX PSY 3610 power supply module . . . . . . . . . . . . . . 399 Chapter 49 TSX PSY 5520 power supply module . . . . . . . . . . . . . . . . . . . 401 Characteristics of the TSX PSY 5520 power supply module . . . . . . . . . . . . . . 401 35011052.06 07/2008 11 Part VI Process and AS-i supply. . . . . . . . . . . . . . . . . . . . . . . . . 403 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403 Chapter 50 Process and AS-i supply: introduction . . . . . . . . . . . . . . . . . 405 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405 General introduction to Process and AS-i power supply modules . . . . . . . . . . . 406 Physical description of TBX SUP 10 supply block . . . . . . . . . . . . . . . . . . . . . . . 407 Physical description of the TSX SUP 1011 supply module . . . . . . . . . . . . . . . . 408 Physical description of TSX 1021/1051 supply modules . . . . . . . . . . . . . . . . . . 409 Physical description of the TSX SUP A02 supply module . . . . . . . . . . . . . . . . . 411 Description of TSX SUP 1101/A05 supply blocks . . . . . . . . . . . . . . . . . . . . . . . 412 Physical description of the support board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413 Process supply: auxiliary functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415 AS-i supply module: dedicated features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417 Chapter 51 Process and AS-i suppliers: installation . . . . . . . . . . . . . . . . 419 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 TBX SUP 10 dimensions/mounting/connections . . . . . . . . . . . . . . . . . . . . . . . . 420 Dimensions/mounting Process and AS-i supply modules . . . . . . . . . . . . . . . . . 422 TSX SUP 1101/A05 supply block dimensions/mounting . . . . . . . . . . . . . . . . . . 427 Summary of mounting methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 429 Chapter 52 Process supply modules: connections . . . . . . . . . . . . . . . . . 431 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 431 Connection of TSX SUP 1011/1021 power supplies . . . . . . . . . . . . . . . . . . . . . 432 Connection of TSX SUP 1051 power supplies . . . . . . . . . . . . . . . . . . . . . . . . . 434 Connection of TSX SUP 1101 power supplies . . . . . . . . . . . . . . . . . . . . . . . . . 436 Chapter 53 Connecting AS-i supply modules. . . . . . . . . . . . . . . . . . . . . . 439 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439 Connection of TSX SUP A02 power supply modules . . . . . . . . . . . . . . . . . . . . 440 Connecting TSX SUP A05 supply modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442 General precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446 Chapter 54 Process and AS-i supply module characteristics. . . . . . . . . 449 At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 449 Electrical characteristics of process supply modules: TBX SUP 10 and TSX SUP 1011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 Electrical characteristics of process supply modules: TSX SUP 1021/1051/1101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452 Electrical characteristics of AS-i supply modules: TSX SUP A02/A05 . . . . . . . 454 Physical environmental characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 457 Index 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 459 35011052.06 07/2008 Safety Information § Important Information NOTICE Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists, which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a potentially hazardous situation, which, if not avoided, can result in death, serious injury, or equipment damage. CAUTION CAUTION indicates a potentially hazardous situation, which, if not avoided, can result in injury or equipment damage. 35011052.06 07/2008 13 Safety Information PLEASE NOTE Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. © 2008 Schneider Electric. All Rights Reserved. 14 35011052.06 07/2008 About the Book At a Glance Document Scope This manual describes the installation of the Premium range of PLCs and their main accessories: It is made up of 6 sections: 1 General introduction to a TSX P57 PLC station and a PCX 57 PLC station, 2 Standard and extendable TSX RKY racks , z 3 TSX P57 Premium Processors, z 4 PCX 57 Atrium Processors, z 5 TSX PSY power supply modules, z 6 Process and AS-i Power Supplies. z z Validity Note The updated version of this manual takes the new processors into account. User Comments We welcome your comments about this document. You can reach us by e-mail at [email protected] 35011052.06 07/2008 15 About the Book 16 35011052.06 07/2008 Premium and Atrium PLC stations I At a Glance Aim of this Part The Part gives a general introduction to the Premium TSX P57 PLC station and the Atrium PCX 57 PLC station. What's in this Part? This part contains the following chapters: Chapter Chapter Name Page Introduction to Premium and Atrium PLC stations 19 2 General introduction to the components of a PLC station 23 3 General introduction to the different configurations of a PLC station 47 4 Operating Standards and Conditions 55 1 35011052.06 07/2008 17 TSX P57/PCX 57 stations 18 35011052.06 07/2008 Introduction to Premium and Atrium PLC stations 1 At a Glance Aim of this Chapter This Chapter gives a general introduction to TSX P57 and PCX 57 PLC stations. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page TSX P57 PLC station 20 PCX 57 PLC station 21 19 Introduction to Premium and Atrium PLC stations TSX P57 PLC station General Premium TSX P57 automated platform processors manage the entire PLC station, which is made up of "Discrete" input/output modules, analog input/output modules and application-specific modules. These can be distributed over one or several racks connected to the bus X or the field bus. Illustration Example of a TSX P57 PLC station: 7 5 1 Number table 3 4 Description according to the addresses in the diagram above: Number 20 2 6 Description 1 Double format power supply module. 2 Processor module. 3 Bus X extension module. 4 Input/output module. 5 Standard format power supply module. 6 Processor module. 7 TSX RKY rack. 35011052.06 07/2008 Introduction to Premium and Atrium PLC stations PCX 57 PLC station General Atrium PCX 57 coprocessors are built into a PC and manage an entire PLC station composed of the same input/output modules as the Premium processors (i.e. "Discrete", analog, application and communication modules). These modules can be distributed over one or more racks connected to the bus X. Illustration Example of a PCX 57 PLC station: 4 3 2 1 Number table 35011052.06 07/2008 Description according to the addresses in the diagram above: Number Description 1 Coprocessor. 2 Supply module. 3 Input/output modules. 4 TSX RKY rack. 21 Introduction to Premium and Atrium PLC stations 22 35011052.06 07/2008 General introduction to the components of a PLC station 2 At a Glance Aim of this Chapter The aim of this Chapter is to provide an overview of the different components which may make up a PLC station. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page General Introduction to TSX P57 Processors 24 General introduction to PCX 57 processors 26 General introduction to TSX RKY racks 27 General introduction to TSX PSY power supply modules 28 General introduction to Process and AS-i TSX SUP and TSX 1021/1051 power supply modules 29 General introduction to the TSX REY bus X extension module 31 General introduction to TSX DEY/DSY/DMY input/output modules 32 General introduction to TSX CTY/CCY counting modules 34 Introduction to TSX CAY axis control modules 35 General introduction to TSX CFY step by step control modules 37 General introduction to TSX SCY/ETY communication 38 General introduction to the AS-i bus interface module: TSX SAY 43 General introduction to the TSX ISPY weighing module 44 General introduction to the TSX FAN ventilation module 45 General introduction to the TSX PAY emergency stop monitoring module 46 23 General introduction to the components of a PLC station General Introduction to TSX P57 Processors General Points Each PLC station is provided with a processor, chosen according to: its integration type: integration on rack or integration in a PC, the processing power necessary: number of discrete I/Os, analog I/Os, etc. , z memory capacity, z processing type: sequential or sequential + process control. z z See TSX P57/TSX H57 Premium processors, p. 145. Table of different sequential and rack-insertable processor format types: Processor Illustration Standard format processors: z TSX P57 103, z TSX P57 153. Standard format processors with heat sink: z TSX P57 353 LA, 24 35011052.06 07/2008 General introduction to the components of a PLC station Processor Illustration Double format processors: z TSX P57 203, z TSX P57 253, z TSX P57 303/303A, z TSX P57 353/353A, z TSX P57 453/453A. Double format processors with on-board Ethernet: z TSX P57 2623, z TSX P57 2823, z TSX P57 3623/3623A, z TSX P57 4823/4823A. 35011052.06 07/2008 25 General introduction to the components of a PLC station General introduction to PCX 57 processors General points Installed on the ISA bus of an industrial or office PC running in a Windows 95 or NT environment, they are used to control a PLC station. Also, installation of a communication driver enables transparent communication between the host PC and the processor, without the need for another programming terminal. There are two types of sequential Atrium PCX 57 processor that can be integrated in a PC: z z PCX 57 203, PCX 57.353. See Atrium PCX 57 processors, p. 283. Illustration Illustration of a PCX 57 processor: PCX 57 203/353 26 35011052.06 07/2008 General introduction to the components of a PLC station General introduction to TSX RKY racks General points Two families of racks are offered: Standard racks 6, 8 and 12 positions: they are used to build a PLC station which is limited to a single rack, z Extendable racks 4, 6, 8 and 12 positions: they are used to make up a PLC station that can contain up to: z a maximum of 16 racks if the station is made up of racks with 4, 6, or 8 positions, z a maximum of 8 racks if the station is made up of racks with 12 positions. z See TSX RKY.. standard and extendable racks, p. 65. Examples The following illustration shows the standard 6-position TSX RKY rack: The following illustration shows the extendable 12-position TSX RKY rack: X Bus 35011052.06 07/2008 27 General introduction to the components of a PLC station General introduction to TSX PSY power supply modules General points Each rack requires a power supply module (see TSX PSY supply modules, p. 339) defined according to the distributed network (alternating or direct current) and the power required for the rack. There are two types of modules: z z Illustration standard format power supply module, double format power supply module. The following illustration shows the two formats for TSX PSY power supply modules: standard format supply module for alternating or direct current network 28 double format supply module for alternating or direct current network 35011052.06 07/2008 General introduction to the components of a PLC station General introduction to Process and AS-i TSX SUP and TSX 1021/1051 power supply modules Process power supply modules A wide range of power supply units and modules are offered to meet your needs in the best possible way. Controlled by Premium TSX/PCX PLCs and designed to supply the peripherals of an automation system with 24 VDC, they can all be mounted on a Telequick AM1-PA mounting board and some can be mounted on a AM1-DP200 / DE 200 central DIN rail. SeeProcess and AS-i supply, p. 403. Illustration The following illustration shows the various types of TSX SUP and TSX 1021/1051 process power supply modules: 24 VDC / 1A 24 VDC / 1A 24 VDC / 2A 24 VDC / 5A 24 VDC / 10A 35011052.06 07/2008 29 General introduction to the components of a PLC station AS-i power supply module They are designed to supply 30 VDC to components connected to the AS-i field bus. Illustration: 30 VDC AS-i / 2.4 A 30 30 VDC AS-i / 5A and 24 VDC 35011052.06 07/2008 General introduction to the components of a PLC station General introduction to the TSX REY bus X extension module General This module allows the extension of two bus segments from the rack supporting the processor, up to a maximum distance of 250 meters. Each extended segment is able to support racks distributed along the bus X to a maximum length of 100 meters. See X-Bus extension module, p. 125. Illustration: TSX REY bus X extension module 35011052.06 07/2008 31 General introduction to the components of a PLC station General introduction to TSX DEY/DSY/DMY input/output modules Discrete inputs/ outputs A wide range of discrete input/output modules (Installation Manual Volume 2) are available to meet your needs in the best possible way. These modules differ from one another in their: Characteristics Description modularity 8, 16, 28, 32 or 64 channels. type of inputs z modules with direct current inputs (24VDC, 48VDC), z modules with alternating current inputs (24VAC, 48VAC, 110VAC, 240VAC). type of outputs z modules with relay outputs, z modules with direct current (24VDC / 0.1A - 0.5A - 2A, 48VDC / 0.25A - 1A) static outputs, z modules with alternating current (24VAC / 130VAC / 1A, 48VAC / 240 VAC / 2A) static outputs. type of connectors screw terminal blocks and HE10 connectors allow the connection of sensors and pre-actuators via the TELEFAST 2 prewiring system. Illustration: HE10 connector 64 I/64 O 32 Screw terminal block connector 32 I/32 O 28 I/O (16+12 O) 16 I 32 I 8 I - 16 I 8 O - 16 O 35011052.06 07/2008 General introduction to the components of a PLC station Analog inputs/ outputs The range of analog input and output modules (Installation Manual Volume 5) can meet your main needs. These modules differ from one another in their: Characteristics Description modularity 4, 8, 16 channels. performance and range of signals offered voltage/current, thermoelectric couple, multirange (thermoelectric couple, heat probe, voltage/current). type of connectors screw terminal blocks or 25-pin SUB D connectors allow the connection of the sensors via the TELEFAST 2 prewiring system. Example: 25-pin SUB D connectors Example: screw terminal block connectors 35011052.06 07/2008 33 General introduction to the components of a PLC station General introduction to TSX CTY/CCY counting modules General points Premium and Atrium PLCs offer main counting functions (down-counting, upcounting, up/down counting) from the application-specific "counting" modules. Three modules are offered: a 2-channel module and a 4-channel module for the incremental encoder, with a maximum reading frequency of 40 kHz, z a 2-channel module for: z incremental encoder, with a maximum reading frequency of 500 kHz, z absolute SSI series encoder, with a maximum reading frequency of 2 MHz. z Illustration Illustration of different types of TSX CTY/CCY counting modules: 2-channel module 4-channel module 2-channel module (incremental encoder/absolute series encoder). 34 35011052.06 07/2008 General introduction to the components of a PLC station Introduction to TSX CAY axis control modules General points Using the application-specific "axis control" modules (Installation Manual Volume 3), Premium PLCs can be used to manage movement control applications, driven by servomotors and with an analog value speed setpoint (+/- 10V). Five modules are offered: 35011052.06 07/2008 Module characteristics 2-channel module allows controlled positioning with two independent, linear, limited axes. 2-channel module allows controlled positioning with two independent, circular, infinite axes. 4-channel module allows controlled positioning with four independent, linear, limited axes. 4-channel module allows controlled positioning with four independent, circular axes. 3-channel module allows positioning on 2 or 3 synchronized axes (linear interpolation). 35 General introduction to the components of a PLC station Illustration Illustration of different types of TSX CAY axis control modules: 2-channel module 4-channel module 3-channel module 36 35011052.06 07/2008 General introduction to the components of a PLC station General introduction to TSX CFY step by step control modules General points Using application-specific "step by step command" modules (Installation Manual Volume 3), Premium and Atrium PLCs can be used to manage movement control modules, controlled by translators with a frequency speed setpoint. Two modules are offered: z z Illustration a 1-channel module which is used to control a translator, a 2-channel module which is used to control two translators, Illustration of different types of TSX CFY modules: 1-channel 35011052.06 07/2008 2-channel 37 General introduction to the components of a PLC station General introduction to TSX SCY/ETY communication General points Different modes of communication (Installation Manual Volume 4)can be used with Premium PLCs: TSX processor communication on the terminal port: these have two terminal ports (TER) and (AUX), a non-insulated RS 485 serial link, UNI-TELWAY or character mode protocol. These terminal ports can be used to connect: z a programming terminal and/or an operator dialog console (UNI-TELWAY master mode), z the station to a multipoint UNITELWAY link (master or slave UNI-TELWAY mode), z a printer or a terminal in character mode. Note: the communication protocol, as defined in the configuration, is identical for both ports. z PSX processor communication on the terminal port: these have one terminal port (TER), a non-insulated RS 485 serial link, UNITELWAY or character mode protocol. As with TSX processors, these can be used to connect: z a programming terminal or an operator dialog console (UNI-TELWAY master mode), z the station to a multipoint UNITELWAY link (master or slave UNI-TELWAY mode), z a printer or a terminal in character mode. z Master FIPIO communication, built-in to some processors, TSX P57x53 and PCX P57 353 processors feature as standard a master FIPIO link, used to provide remote operation (maximum 15 kms) of devices such as: - discrete I/Os, - analog I/Os, - speed drives, - operation and supervising stations, - devices, - etc. z Communication by means of PCMCIA cards which can be built into the processor or the application-specific communication module TSX SCY 21601: the processors and the application-specific communication module TSX SCY 21601 have a slot which is used for accommodating an extended type III PCMCIA communication card, z Communication via application-specific modules: TSX SCY 2160 module: This module, which can be integrated in all TSX/PCX Premium PLC station racks, has: z 38 35011052.06 07/2008 General introduction to the components of a PLC station a built-in communication channel (1), multiprotocol (UNITELWAY, Modbus/ Jbus, character mode), isolated RS 485 serial link, z a slot (2) for receiving an extended PCMCIA type III format communication card. TSX ETY 110/4102/5102 module: Module enabling communication in an Ethernet multi-network architecture with a communication channel providing two types of connection: z connection to an ETHWAY network, z connection to an TCP_IP network. z PCMCIA cards 35011052.06 07/2008 PCMCIA type III format communication cards (see TSX P57/TSX H57 processors: diagnostics, p. 177). 39 General introduction to the components of a PLC station Illustrations The following table illustrates the different modes of communication: Illustration Description TER and AUX ports on TSX processors. TER ports on PCX processors. FIPIO link on TSX processors. 40 35011052.06 07/2008 General introduction to the components of a PLC station Illustration Description FIPIO link on PCX processors. Built-in Ethernet links for TSX P57 ••23 processors. Communication by means of PCMCIA cards which can be built in to the processor or the module. 35011052.06 07/2008 41 General introduction to the components of a PLC station Illustration Description Communication via application-specific module TSX SCY 21601: z 1 : built-in communication channel, z 2 : slot for PCMCIA card. Communication via application-specific module TSX ETY 110. 42 35011052.06 07/2008 General introduction to the components of a PLC station General introduction to the AS-i bus interface module: TSX SAY General points This is a module which is used to connect an AS-i bus to a Premium TSX/PCX PLC station. This master module (Installation Manual Volume 4) manages and coordinates bus access. It transmits data to all slaves and receives data from them. Illustration 35011052.06 07/2008 Illustration of the TSX SAY 100 module: 43 General introduction to the components of a PLC station General introduction to the TSX ISPY weighing module General Using the TSX ISPY 101 and TSX ISPY 101 application-specific "weighing" modules. Premium PLCs can be used to manage weighing applications: dosage, multi-product dosage, grading, flow control, weight totalizer, etc. This module offers a measurement input for a maximum of 8 sensors, 2 rapid discrete outputs and a serial link for a displayed report. Illustration 44 Illustration of the TSX ISPY 100/101 module: 35011052.06 07/2008 General introduction to the components of a PLC station General introduction to the TSX FAN ventilation module General Depending on the rack modularity (4, 6, 8 or 12 positions), one, two or three ventilation modules can be installed above each rack to help cool the different modules by forced convection. These ventilation units should be used in the following scenarios: z z Ambient temperature in the 25°C...60°C range, Ambient temperature in the 60°C70°C range. Three types of ventilation module are offered: ventilation module with 110 VAC power supply, ventilation module with 220 VAC power supply, z ventilation module with 24 VDC supply, z z See Ventilation module, p. 113. Illustration 35011052.06 07/2008 Illustration of the TSX FAN ventilation module: 45 General introduction to the components of a PLC station General introduction to the TSX PAY emergency stop monitoring module General points These are modules (Installation Manual Volume 2) designed to control machine emergency stop circuits per category 4 according to the EN 954-1 standard. Two modules are offered: z z 1 module consisting of 12 inputs and 2 outputs, 1 module consisting of 12 inputs and 4 outputs. Illustration of the TSX PAY module: 46 35011052.06 07/2008 General introduction to the different configurations of a PLC station 3 At a Glance Aim of this Chapter This Chapter gives a general introduction to the different configurations which are possible for TSX and PCX PLC stations. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Different types of Premium PLC Stations 48 Different types of PLC stations with Atrium processors. 51 47 General introduction to the different configurations of a PLC station Different types of Premium PLC Stations The choice of rack (standard or extendable) and processor type defines the maximum capacities of a Premium PLC station. z TSX P57 10 Station the TSX P57 stations are composed of TSX P57 103,153 and 353LA single format processors and TSX P57 203/253/2623/2823/303/303A/353/353A/3623/ 3623A/453/453A/4823/4823A double format processors. Without bus X extension module: Station with standard rack: 1 rack, 6, 8 or 12 positions. Station with extendable rack: 2 racks 12 positions or, 4 racks 4, 6 or 8 positions, maximum length of bus X: 100 meters 100 m max General Points With bus X extension module: Principal bus X segment Bus X ≤ 100 m Remote bus X segment Remote bus X Bus X ≤ 250 meters ≤ 100 m Station with extendable racks: 2 racks 12 positions or, 4 racks 4, 6 or 8 positions, 2 remotes possible, maximum length of a remote: 250 meters, maximum length of the bus X segments: 100 meters. Processor 48 35011052.06 07/2008 General introduction to the different configurations of a PLC station TSX 57 20/30/40 Station Without bus X extension module: Station with standard rack: 1 rack, 6, 8 or 12 positions. Station with extendable rack: 8 racks 12 positions or, 16 racks 4, 6 or 8 positions, maximum length of bus X: 100 meters 100 meters max. 35011052.06 07/2008 49 General introduction to the different configurations of a PLC station With bus X extension module: Principal bus X segment Segment 1 remote from bus X Remote bus X ≤ 250 meters Bus X ≤ 100 m Bus X ≤ 100 m Processor Station with extendable racks: 8 racks 12 positions or, 16 racks 4, 6 or 8 positions, 2 remotes possible, maximum length of a remote: 250 meters, maximum length of the bus X segments: 100 meters. 50 Remote bus X Bus X ≤ 250 meters ≤ 100 m Segment 2 remote from bus X 35011052.06 07/2008 General introduction to the different configurations of a PLC station Different types of PLC stations with Atrium processors. General points By selecting the PCX 57 203 or 353 processor type, you set the maximum capacities of a Premium PCX PLC station. This type of station, with the processor integrated in a PC, will be controlled with extendable racks. PCX 57 203 station Without bus X extension module: Extendable racks TSXRKY∞∞EX PCX 57203 X1 PC Station with extendable racks: 2 racks 12 positions or, 4 racks 4, 6 or 8 positions, maximum length of bus X (X1+X2): 100 meters. X2 With bus X extension module: Segment 1 remote from bus X Bus X ≤ 100 m PCX 57353 PC Segment 2 remote from Bus X Station with extendable racks: 2 racks 12 positions or, 4 racks 4, 6 or 8 positions, 2 possible remotes, maximum length of a remote: 250 meters – X1, maximum length of the bus X segments: 100 meters. 35011052.06 07/2008 51 General introduction to the different configurations of a PLC station PCX 57 353 station Without bus X extension module: Extendable racks TSXRKY∞∞EX PCX 57353 X1 PC Station with extendable racks: 8 racks 12 positions or, 16 racks 4, 6 or 8 positions, maximum length of bus X (X1+X2): 100 meters X2 52 35011052.06 07/2008 General introduction to the different configurations of a PLC station With bus X extension module: Segment 1 remote from bus X Bus X remote bus X ≤ 100m ≤ 250m-X1 PCX 57353 Principal bus X segment Bus X remote bus X ≤ 100m ≤250m-X1 Segment 2 remote from bus X Station with extendable racks: 8 racks 12 positions or, 16 racks 4, 6 or 8 positions, two possible remotes, maximum length of a remote: 250 meters – X1 maximum length of the bus X segments: 100 meters 35011052.06 07/2008 53 General introduction to the different configurations of a PLC station 54 35011052.06 07/2008 Operating Standards and Conditions 4 At a Glance Aim of this Chapter This chapter deals with the operating standards and conditions of Premium and Atrium PLCs. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Standards and Certification 56 Operating conditions and environmental conditions to be avoided 57 Premium PLC protection processing 64 55 Operating Standards and Conditions Standards and Certification General Premium and Atrium PLCs have been developed to conform to the principal national and international standards for industrial electronic PLC equipment. Programmable PLCs: specific requirements: functional characteristics, resistance, safety etc. IEC 61131-2, CSA 22.2 N° 142, UL 508 z Merchant navy requirements of the major international organizations: ABS, BV, DNV, GL, LROS, RINA, RRS, CCS etc. z Adhering to European Directives: Low Voltage: 73/23/EEC amendment 93/68/EEC Electromagnetic Compatibility: 89/336/EEC amendments 92/31/EEC and 93/68/ EEC z Electric qualities and self-extinguishability of insulating materials: UL 746C, UL 94 z Danger Zones Cl1 Div2 CSA 22.2 N° 213 z DANGER Explosion Hazard: THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D OR NON-HAZARDOUS LOCATIONS ONLY "WARNING: "EXPLOSION HAZARD - DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS" Failure to follow these instructions will result in death or serious injury. 56 35011052.06 07/2008 Operating Standards and Conditions Operating conditions and environmental conditions to be avoided Operating temperature/ hygrometry/ altitude Data table: Ambient temperature when operative 0°C to +60°C (IEC 1131-2 = +5°C to +55°C) Relative humidity 10% to 95% (without condensation) Altitude 0 to 2000 meters Power supply voltages Data table: Voltage nominal 24 VDC 48 VDC 100 to 240VAC 100...120/200...240 VAC limit 19 to 30 VDC 19...60VDC (1) 90 to 264 VAC 90 to 140/190 to 264VAC nominal - - 50/60 Hz 50/60 Hz limit - - 47/63 Hz 47/63 Hz duration ≤ 1 μs ≤ 1 μs ≤ 1/2 period ≤ 1/2 period repetition ≥1s ≥1s ≥1s ≥1s Frequency Brown-outs Harmonic rate - - 10% 10% Residual ripple included 5% 5% - - (1) Possible up to 34 VDC, limited to 1 hour every 24 hours. For TSX PSY 1610 and TSX PSY 3610 power supplies, and when using relay output modules, this scope is reduced to 21.6V...26.4V. 35011052.06 07/2008 57 Operating Standards and Conditions Human and material safety Data table: Test Designation Norms Levels Dielectric rigidity and Isolation resistance * IEC 61131-2 UL 508 CSA 22-2 N°142 IEC 60950 24 - 48 V Power supply 100 -220 V Power supply < 48V Discrete I/Os > 48V Discrete I/Os > 10 MΩ Maintaining ground connections* IEC 61131-2 UL 508 CSA 22-2 N°142 < 0.1 Ω / 30 A / 2 min Leakage Current * CSA 22-2 N°142 IEC 60950 < 3.5 mA fixed device Enclosures for protection * IEC 61131-2 CSA 22-2 N°142 IEC 60950 IP 20 Impact Resistance Drop / 1.3 m / 500 g Sphere CSA 22-2 N°142 IEC 60950 1500 Vrms 2000 Vrms 500 Vrms 2000 Vrms Legend *: Tests required by EC directives Note: The devices must be installed and wired according to the directions in the TSX DG KBL• manual. 58 35011052.06 07/2008 Operating Standards and Conditions Resistance of devices to power supply L.F. turbulence Data table: Test Designation Norms Levels Voltage and frequency Variation * EN 50082-1 Un 15% / Nf 5% Un 20% / Nf 10% Continuous voltage variation * EN 50082-1 0.85 Un - 1.2 Un + 5% ripple maximum Harmonic 3 * IEC 61131-2 10% Un 0° / 5 min - 180° / 5 min Momentary Interruptions * IEC 61131-2 AC DC Voltage peaks and troughs * IEC 61131-2 Un-0-Un; Un / 60s 3 cycles separated by 10 s Un-0-Un; Un / 5s 3 cycles separated by 1 to 5 s Un-0.9-Un; Un / 60s 3 cycles separated by 1 to 5 s 30 min x 2 5sx2 30 + 30 min 10 ms 1 ms Legend Un: Nominal Voltage Nf: Nominal Frequency Ud: Power-on detection level *: Tests required by EC directives Note: The devices must be installed and wired according to the directions in the TSX DG KBL• manual. 35011052.06 07/2008 59 Operating Standards and Conditions Resistance to H.F. turbulence Data table: Test Designation Norms Levels Amortized oscillatory wave * IEC 61131-2 IEC 61000-4-12 AC / DC 24 V Discrete I/Os 1 kV SM 1 kV SM Fast transients (bursts) EN 50082-1 * IEC 61000-4-4 AC / DC Power Supply 48 V > Discrete I/Os other ports 2 kV WM / CM 2 kV CM 1 kV CM Hybrid shockwave AC / DC Power Supply AC Discrete I/Os DC Discrete I/Os Shielded Cable 2 kV WM / 1 kV SM 2 kV WM / 1 kV SM 2 kV WM / 0.5 kV SM 1 kV CM IEC 61000-4-5 Electrostatic Discharge IEC 61131-2 * IEC 61000-4-2 6 kV contact 8 kV air Electromagnetic Field * EN 50082-2 IEC 61000-4-3 10 V/m, 80MHz - 2 GHz Sinusoidal modulation amplitude 80% / 1kHz Conduit Turbulence * 10 V 0.15 MHz - 80 MHz Sinusoidal modulation amplitude 80% / 1kHz EN 50082-2 IEC 61000-4-6 Legend SM: Serial mode CM: Common Mode WM: Wire Mode *: Tests required by EC directives Note: The devices must be installed and wired according to the directions in the TSX DG KBL• manual. 60 35011052.06 07/2008 Operating Standards and Conditions Electromagnetic Emissions Data table: Test Designation Norms Levels Conduction Limits * EN55022/55011 EN50081-2 Class A 150 kHz - 500 kHz quasi-peak 79 dB mV average 66 dB mV 500 kHz -30 kHz quasi-peak 73 dB mV average 60 dB mV Emission Limits *(1) EN55022/55011 EN50081-2 Class A d = 10 m 30 kHz -230 kHz quasi-peak 30 dB mV/m 230 kHz -1 kHz quasi-peak 37 dB mV/m Legend (1) This test is carried out outside the casing, with the devices secured to a metallic grill and wired as shown in the TSX DG KBL• Manual. *: Tests required by EC directives Note: The devices must be installed and wired according to the directions in the TSX DG KBL• manual. 35011052.06 07/2008 61 Operating Standards and Conditions Resistance to climatic variation Data table: Test Designation Norms Levels Dry heat IEC60068-2-2 Bd 60°C / 16h (E.O) 40°C / 16h (E.F) Cold IEC60068-2-1 Ad 0°C / 16h Continuous humid heat IEC60068-2-30 Ca 60°C / 93% Hr /96h (E.O) 40°C / 93% Hr /96h (E.F) Cyclical humid heat IEC60068-2-30 Db (55°C E.O / 40°C E.F); - 25°C / 93-95% Hr 2 cycles: 12 o' clock - 12h o' clock Cyclical temperature variations IEC60068-2-14 Nb 0°C; -60°C / 5 Cycles: 6 o'clock-6 o'clock (E.O.) 0°C; -40°C / 5 Cycles: 6 o'clock-6 o'clock (E.F) Temperature Rise IEC61131-2 UL508 CSA22-2 N°142 Ambient temperature: 60°C Legend E.O: Device open E.F: Device closed Hr: Relative Humidity Resistance to mechanical constraints Data table: Test Designation Standards Levels Sinusoidal vibrations IEC60068-2-6 Fc 3 Hz - 100 Hz / 1 mm amplitude / 0.7 Gn Endurance: rf / 90 min / axis (Q limit) < 10 3 Hz - 150 Hz / 1.5 mm / 2 Gn Endurance: 10 cycles (1 octave / min) Half-sinus shocks IEC60068-2-27 Ea 15 Gn x 11 ms 3 shocks / direct. / axis Legend rf: Resonance Frequency Q: Amplification Coefficient 62 35011052.06 07/2008 Operating Standards and Conditions Resistance to climatic variation Resistance to mechanical constraints 35011052.06 07/2008 Data table: Test Designation Standards Levels Dry heat whilst inoperative IEC60068-2-2 Bb 70°C / 96h Cold whilst inoperative IEC60068-2-1 Ab -25°C / 96h Humid heat whilst inoperative IEC60068-2-30 dB 60°C; - 25°C / 93-95% Hr 2 cycles: 12 o' clock - 12h o' clock Thermal shocks whilst inoperative IEC60068-2-14 Na -25°C; -70°C / 2 Cycles: 3 o'clock - 3 o'clock Standards Levels Flat free drop IEC60068-2-32 Ed 10 cm / 2 drops Free drop from controlled position IEC60068-2-31 Ec 30° or 10 cm / 2 drops Random free drop (conditioned material) IEC60068-2-32 Method 1 1 m / 5 drops Data table: Test Designation 63 Operating Standards and Conditions Premium PLC protection processing General points PLCs in the Premium and Atrium range meet AP (all-climate processing) processing requirements. For installations used in industrial production workshops or in environments which come under the title HP (processors in heat and humidity) processing, the Premium PLCs must be inserted into a protection casing (minimum IP54 as outlined by standards IEC 60664 and NF C 20 040). Premium PLCs have an IP20 protection index. They can thus be installed without a protection casing in restricted-access areas which do not exceed Pollution Degree 2 (control room free of machines or any activity creating dust). The Atrium card is designed for integration into a host PC. The host device must therefore conform to the IP20 protection index. CAUTION Maintaining IP protection index For a rack to conform to the IP20 protection index, the unoccupied module slots must be protected by a TSX RKA 02 protection cover. Failure to follow these instructions can result in injury or equipment damage. 64 35011052.06 07/2008 TSX RKY.. standard and extendable racks II At a Glance Subject of this Part This part concerns TSX RKY.. standard and extendable racks What's in this Part? This part contains the following chapters: 35011052.06 07/2008 Chapter Chapter Name Page 5 Introduction to TSX RKY .. standard/extendable racks. 67 6 TSX RKY.. standard and extendable racks : installation/ mounting 77 7 TSX RKY.. standard and extendable racks: functions 85 8 TSX RKY Racks: accessories 99 9 Ventilation module 113 10 X-Bus extension module 125 65 TSX RKY.. standard and extendable racks 66 35011052.06 07/2008 Introduction to TSX RKY .. standard/extendable racks. 5 At a Glance Aim of this Chapter This Chapter deals with: z z What's in this Chapter? 35011052.06 07/2008 general points regarding TSX RKY racks, the physical description of these racks. This chapter contains the following topics: Topic Page Standard and extendable TSX RKY racks 68 Standard rack: description 72 Extendable rack: description 74 67 Introduction to TSX RKY .. standard/extendable racks. Standard and extendable TSX RKY racks General points TSX RKY racks form the base unit of Premium PLCs. These racks serve the following functions: Mechanical function: they are used to mount a set of modules for a PLC station (i.e. supply modules, processors, discrete/analog input/output modules, application-specific modules). They can be mounted in cabinets, machine frames or on panels. z Electrical function: the racks have a built-in bus, called bus X, which distributes: z the required supply for each module on the same rack, z service signals and data for the whole PLC station when this is made up of several racks. z Note: two families of racks are offered in several modularities (4, 6, 8 and 12 positions): z standard racks, z extendable racks. 68 35011052.06 07/2008 Introduction to TSX RKY .. standard/extendable racks. Standard racks They are used to make up a PLC station which is limited to a single rack. This table presents the different standard racks: 35011052.06 07/2008 Designation Illustration TSX RKY 6 6-position rack TSX RKY 8 8-position rack TSX RKY 12 12-position rack 69 Introduction to TSX RKY .. standard/extendable racks. Extendable racks They are used to make up a PLC station which can have: z z a maximum of 8 TSX RKY 12 EX racks, a maximum of 16 TSX RKY 4EX/6EX/8EX racks. These racks are distributed on a bus called bus X, whose maximum length is limited to 100 meters. A bus extension cable assures rack-to-rack bus continuity. For applications which require a greater distance, a bus X extension module allows the extension of two bus X segments from the rack which is supporting the processor to a maximum distance of 250 meters. This table presents the different extendable racks: 70 Designation Illustration TSX RKY 4EX 4-position rack TSX RKY 6EX 6-position rack 35011052.06 07/2008 Introduction to TSX RKY .. standard/extendable racks. 35011052.06 07/2008 Designation Illustration TSX RKY 8EX 8-position rack TSX RKY 12EX 12-position rack 71 Introduction to TSX RKY .. standard/extendable racks. Standard rack: description At a Glance They are used to make up a PLC station which is limited to a single rack. Illustration Standard rack 1 3 9 6 4 6 8 72 7 5 6 2 35011052.06 07/2008 Introduction to TSX RKY .. standard/extendable racks. Description The following table describes the different elements of a standard rack. Number 35011052.06 07/2008 Description 1 Metal sheet which: z supports the bus X electronic card, and protects against EMI and ESD interference. z supports the modules, z maintains the rack’s physical rigidity. 2 Holes to be used as anchor-points for module pins. 3 Female 48-pin 1/2 DIN connectors for connecting each module to the rack. When racks are delivered, these connectors are protected by covers, which must be removed before modules are installed. The connector on the farthest left marked PS is always dedicated to the rack supply module. The other connectors marked 00 to .. are for receiving all the other module types. 4 Screw-holes for the module-mounting screws. 5 Guide-hole to assist in mounting the supply module. As supply modules have a projecting part on the back, this module cannot be mounted in any other position. 6 Holes for mounting the rack onto a support. These holes can take M6 screws. 7 Slot to hold the label for the rack address. 8 Slot to hold the label for the station network address. 9 Ground terminals for grounding the rack. 73 Introduction to TSX RKY .. standard/extendable racks. Extendable rack: description At a Glance They are used to form a PLC station which can be made up of several racks. Illustration Extendable rack 1 3 9 6 4 10 8 11 7 6 5 6 74 2 35011052.06 07/2008 Introduction to TSX RKY .. standard/extendable racks. Description The following table describes the different elements of an extendable rack. Number 35011052.06 07/2008 Description 1 Metal sheet which: z supports the bus X electronic card, and protects against EMI and ESD interference. z supports the modules, z maintains the rack’s physical rigidity. 2 Holes to be used as anchor-points for module pins. 3 Female 48-pin 1/2 DIN connectors for connecting each module to the rack. When racks are delivered, these connectors are protected by covers, which must be removed before modules are installed. The connector on the farthest left marked PS is always dedicated to the rack supply module. The other connectors marked 00 to .. are for receiving all the other module types. 4 Screw-holes for the module-mounting screws. 5 Guide-hole to assist in mounting the supply module. As supply modules have a projecting part on the back, this module cannot be mounted in any other position. 6 Holes for mounting the rack onto a support. These holes can take M6 screws. 7 Slot to hold the label for the rack address. 8 Slot to hold the label for the station network address. 9 Ground terminals for grounding the rack. 10 Microswitch for coding the rack address (extendable racks only). 11 Female 9-pin SUBD connectors for extending the bus X to another rack (extendable rack only). 75 Introduction to TSX RKY .. standard/extendable racks. 76 35011052.06 07/2008 TSX RKY.. standard and extendable racks : installation/ mounting 6 At a Glance Aim of this Chapter This chapter deals with: z z What's in this Chapter? 35011052.06 07/2008 rack installation, mounting these racks. This chapter contains the following topics: Topic Page Installing Racks 78 mounting and fixing racks 81 Connection of the ground to a TSX RKY rack 84 77 TSX RKY.. standard and extendable racks: installation/mounting Installing Racks Introduction When mounting TSX RKY •• racks, certain installation rules must to be followed. Rack Installation Rules: Description z 1 As the different modules (e.g. supply, processors, discrete I/O, etc.) are cooled by natural convection, it is compulsory in order to facilitate ventilation (see Ventilation module, p. 113) to install the different racks horizontally and vertically. z 2 If several racks are installed in the same cabinet, you are advised to comply with the following advice on layout: z leave at least 150 mm between two racks placed on top of each other, to allow room for cable troughs and help air circulation. z you are advised to install the devices which generate heat (eg transformers, process supply, power contacts, etc.) above the racks, z leave at least 100 mm on each side of a rack to allow room for cabling and to help air circulation. Note: If the hardware, other than the metal electrical cabinet, is installed in an area with emissions limits between 30 MHz and 1GHz (as per EN 55022), you are advised to use racks TSXRKY 8EX or TSXRKY6EX instead of TSXRKY8 and TSXRKY6. 78 35011052.06 07/2008 TSX RKY.. standard and extendable racks: installation/mounting Illustration The following illustration shows the rules for installation a Greater than or equal to 50 mm. 1 Installation or casing. 2 Trough or cable tray. 35011052.06 07/2008 79 TSX RKY.. standard and extendable racks: installation/mounting The following illustrations show the overall dimensions of TSX RKY •• racks. 165 mm (1) TSX RKY 4EX 151.5 mm Overall Rack Dimensions: Illustrations 187.9 mm TSX RKY 6/6EX 165 mm (1) 160 mm (1) 200 mm (2) 261.6 mm TSX RKY 8/8EX 335.3 mm TSX RKY 12/12EX 482.6 mm (1) With screw terminal block modules. (2) Maximum depth for all types of modules and their associated connectors. 80 35011052.06 07/2008 TSX RKY.. standard and extendable racks: installation/mounting mounting and fixing racks Introduction TSX RKY•• and TSX RKY••EX racks can be mounted: z z on a 35 mm wide DIN mounting rail using M6x25 screws, on a Telequick mounting grid or on a panel. The rules for installation (see Installing Racks, p. 78) are to be always followed, whatever the type of mounting. Mounting on 35 mm wide DIN mounting rail Fixing with four M6x25 screws + washers and AF1-CF56 1/4 turn sliding nuts. Diagram illustrating the mounting (1) TSX RKY 4EX (2) TSX RKY6 and TSX RKY 6EX (3) TSX RKY8 and TSX RKY 8EX (4) TSX RKY 12 and TSX RKY 12EX 35011052.06 07/2008 81 TSX RKY.. standard and extendable racks: installation/mounting Mounting on a panel Plan of screw-holes (dimensions in mm): 4 fixing holes (1) (1) the diameter of the fixing holes must be sufficient to take M6 screws. (1) The diameter of the fixing holes must be such as to allow M6 screws. a and b see table. 82 35011052.06 07/2008 TSX RKY.. standard and extendable racks: installation/mounting Mounting on an AM1-PA Telequick mounting grid Fix the rack using four M6x25 screws + washers and AF1-EA6 clips nuts. Plan of screw-holes (dimensions in mm): the following table presents mounting characteristics according to the different TSX RKY racks: Racks a b Depth TSX RKY 4EX 170.4 mm 187.9 mm 16 mm TSX RKY 6/6EX 244.1 mm 261.6 mm 16 mm TSX RKY 8/8EX 317.8 mm 335.3 mm 16 mm TSX RKY 12/12EX 465.1 mm 482.6 mm 16 mm Note: Maximum tightening torque for fixing screws: 2.0.N.m.(1.6 Lb.-ft.) 35011052.06 07/2008 83 TSX RKY.. standard and extendable racks: installation/mounting Connection of the ground to a TSX RKY rack Grounding racks Functional grounding of the racks is provided by the back, which is made of metal. This means that the PLCs will be guaranteed to conform to environmental norms; assuming, however, that the racks are fixed to a metal support that is correctly connected to ground. The different racks which can make up a TSX P57/TSX H57 PLC station must be mounted either on the same support or on different supports, as long as the latter are correctly interlinked. DANGER Correct grounding procedure Each rack’s grounding terminal must be linked to the protective ground. Use a green/yellow wire with a minimum section of 2.5 mm (12 AWG) and with the shortest length possible. z Maximum torque on the ground connection screw: 2.0 N.m (1.5 lb-ft). z Install to confrom to all local and national codes. z z Failure to follow these instructions will result in death or serious injury. Illustration: support connected to the ground yellow/green wire linked to the ground Note: The PLC’s internal 0V is linked to the ground connection. The ground connection itself being linked to ground. 84 35011052.06 07/2008 TSX RKY.. standard and extendable racks: functions 7 At a Glance Aim of this Chapter This chapter describes the different functions of the TSX RKY.. standard and extendable racks. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Building a PLC station with Premium processor 86 Building a PLC station with Atrium processor 89 PLC station rack addressing 91 The principle of addressing two racks at the same address 93 Module addresses 94 Installing power supplies, processors and other modules 96 85 TSX RKY.. standard and extendable racks: functions Building a PLC station with Premium processor Introduction It is possible to build a PLC station with TSX P57 processor using: z z Building using standard racks 86 standard racks (see Standard racks, p. 69): TSX RKY 6/8/12, extendable racks (see Extendable racks, p. 70): TSX RKY 4EX/6EX/8EX/12EX. Standard racks can be used to build a TSX P57 PLC station limited to a single rack. 35011052.06 07/2008 TSX RKY.. standard and extendable racks: functions Building using extendable racks: TSX RKY 4EX/6EX/8EX/ 12EX Extendable racks can be used to build a PLC station that contains a maximum of: Station Number of racks For a TSX 57 10 station z 2 TSX RKY 12EX racks, z 4 TSX RKY 4EX/6EX/8EX racks. For a TSX 5720, 5730 or 5740 station z 8 TSX RKY 12EX racks, z 16 TSX RKY 4EX/6EX/8EX racks. 100 meters maximum Diagram z (1) The same station can contain 4, 6, 8 and 12 position racks that are linked by Bus X extension cables (see TSX CBY..0K bus X extension cable (II ≥ 02), p. 100) (labeled 1). z (2)The bus X must have a line termination (see Line terminator TSX TLYEX, p. 105) (labeled 2) fitted at each end. 35011052.06 07/2008 87 TSX RKY.. standard and extendable racks: functions Note: The total length of all the TSX CBY ..0K cables used in a PLC station must never exceed 100 meters (328 feet). For applications which require a distance of more than 100 meters between racks, an extension module allows the extension of two bus X segments from the rack supporting the processor, to a maximum distance of 250 meters (820 feet), each bus X segment having a maximum distance of 100 meters. Bus X extension cable Racks are connected by means of TSX CBY..0K bus X extension cables which are connected to the 9-pin SUB D connectors situated on the right and left of each extendable rack. Note: As the idea of in and out does not exist at the level of the 9-pin SUB D connector, a cable can enter or leave using either the right or left-hand connector. Line termination 88 The two racks situated at the ends of the chain must always be fitted with a TSX TL YEX line termination on the unused 9-pin SUB D connectors, labeled A/ and /B. 35011052.06 07/2008 TSX RKY.. standard and extendable racks: functions Building a PLC station with Atrium processor At a Glance It is possible to build a PLC station with PCX 57 processor using extendable racks: TSX RKY 4EX/6EX/8EX/12EX. Building using extendable racks Extendable racks can be used to build a PLC station that contains a maximum of: Station Number of racks For a PCX 57 203 station z 8 TSX RKY 12EX racks, z 16 TSX RKY 4EX/6EX/8EX racks. For a PCX 57 353 station z 8 TSX RKY 12EX racks, z 16 TSX RKY 4EX/6EX/8EX racks. Diagram: TPCX 57 203 X1 PC X2 35011052.06 07/2008 89 TSX RKY.. standard and extendable racks: functions (1) The same station can contain 4, 6, 8 and 12 position racks that are linked by Bus X extension cables (see TSX CBY..0K bus X extension cable (II ≥ 02), p. 100) (labeled 1). z (2) The bus X must have a line termination (see Line terminator TSX TLYEX, p. 105) (labeled 2) fitted at each end. z Note: the total length (X1 + X2) of all the TSX CBY ..0K cables used in a PLC station must never exceed 100 meters (328 feet). For applications which require a distance of more than 100 meters between racks, an extension module allows the extension of two bus X segments from the rack supporting the processor, to a maximum distance of 250 meters (820 feet), each bus segment having a maximum distance of 100 meters. Bus X extension cable Racks are connected by means of TSX CBY••0K bus X extension cables which are connected to the 9-pin SUB D connectors situated on the right and left of each extendable rack and at the top of the front panel of the processor. Note: As the idea of in and out does not exist at the level of the 9-pin SUB D connector, a cable can enter or leave using either the right or left-hand connector. Line termination At manufacture, the equivalent of the line terminator /A is built in to the processor and, due to this, the processor forms a termination of the bus X. The extendable rack located at the end of the chain therefore must always have a TSX TLY line terminator, labeled /B on its unused 9-pin SUB D connector. Note on the PCX 57 processor By default, the PCX 57 processor is equipped to be mounted as the start of the bus X, and thus, the line termination /A is built-in to it in the form of a removable daughterboard. If an application requires the integration of the processor inside a Bus X section, a mechanical kit is supplied with the processor to satisfy this requirement. This mechanical kit is in the form of: z z 90 a daughterboard which is mounted in place of the line termination A/, a shield equipped with a 9-pin SUB D connector for connecting a bus X TSX CBY••0K cable and a cable for connection to the daughterboard. 35011052.06 07/2008 TSX RKY.. standard and extendable racks: functions PLC station rack addressing Introduction Two cases can occur for PLC station rack addressing: z z PLC station built from a standard rack (see Standard racks, p. 69), PLC station built from extendable racks (see Extendable racks, p. 70). Station built from a standard rack The station is always limited to a single rack, thus the rack address is implicit and has a value of 0 (no microswitches). Station built from extendable racks For each station rack an address must be assigned. This address is coded using 4 microswitches found on the rack. Microswitches 1 to 3 are used to code the address of the rack on the bus X (0 to 7), microswitch 4 is used to code two racks (4, 6 or 8 positions) on the same address. This latter functionality is managed by the PL7 Junior or PL7 Pro software version V 3.3 or above. ON position Diagram showing the microswitch Table of rack addresses Rack addresses Position of the micro-switches Note: On delivery, microswitches 1, 2 and 3 are in the ON position (address 0). 35011052.06 07/2008 91 TSX RKY.. standard and extendable racks: functions Assigning addresses to different racks Address 0: this address is always assigned to the rack which supports: z z the TSX P 57 processor physically, the PCX 57 processor virtually. This rack can be located in any position in the chain. Addresses 1 to 7: they can be assigned in any order to all the other extendable racks in the station. Note: the rack address coding must be done before mounting the power supply module. CAUTION Address conflict Each rack must have a unique address other than address 0. Power reset is required after address connection. Failure to do so will result in the racks affected, as well as all their modules showing a fault. Failure to follow these instructions can result in injury or equipment damage. This note only applies to racks with references TSX RKY..EX If two or more racks are at address 0, the rack supporting the processor does not show a fault. Having correctly addressed the racks with faulty addresses, it is necessary to switch off and switch on the rack concerned. 92 35011052.06 07/2008 TSX RKY.. standard and extendable racks: functions The principle of addressing two racks at the same address Illustration The following diagram shows the principle of addressing two racks at the same address. 1 single rack TSX RKY 12EX on the same address 2 single racks TSX RKY 8EX on the same address 2 racks TSX RKY 6EX on the same address Microswitch 4 2 racks TSX RKY 4EX on the same address Note: take into account the following notes: z TSX RKY 12EX racks cannot have a second rack at the same address. z TSX RKY 8EX/6EX/4EX racks can be intermixed. z Two TSX RKY 8EX/6EX/4EX racks at the same address will not necessarily be linked one after the other. The order of physical distribution is not important. 35011052.06 07/2008 93 TSX RKY.. standard and extendable racks: functions Module addresses At a Glance For all standard and extendable racks, the module address is geographical and will depend upon the position of the module on the rack. The address of each position is indicated under each connector - the connector with address PS is always dedicated to the rack power supply. Several addressing cases are possible: z z module addressing on standard racks (see Standard racks, p. 69), module addressing on extendable racks (see Extendable racks, p. 70). Module addressing on standard racks z for a TSX RKY 6: use addresses 00 to 04, for a TSX RKY 8: use addresses 00 to 06, z for a TSX RKY 12: use addresses 00 to 10. Module addressing on extendable racks The address of a module will depend upon the position of microswitch 4: z microswitch 4 in the ON position, the modules will have addresses (00 to x), according to the rack type, z microswitch 4 in the OFF position, the modules will have addresses (08 to y), according to the rack type. This functionality is only managed by the PL7 Junior or PL7 Pro software version V 3.3 or above. z the following table shows the addresses in relation to the position of microswitch 4: 94 Position of microswitch 4 ON OFF TSX RKY 4EX racks 00 to 02 08 to 10 TSX RKY 6EX racks 00 to 04 08 to 12 TSX RKY 8EX racks 00 to 06 08 to 14 TSX RKY 12EX racks 00 to 10 unusable 35011052.06 07/2008 TSX RKY.. standard and extendable racks: functions Illustration Diagram showing the module addresses on rack TSX RKY 8EX Micro-switch 4 Module addresses Note: the shaded addresses are only accessible using PL7 Junior or PL7 Pro software version V 3.3 or above 35011052.06 07/2008 95 TSX RKY.. standard and extendable racks: functions Installing power supplies, processors and other modules Installation on a standard or extendable rack with address 0 and with a Premium processor The rack with address 0 must have a power supply module and the processor module. Premium PLCs have two types of power supply (standard format or double format), the position of the processor will depend upon the type of power supply used. Using a standard format power supply module: z z the power supply module automatically occupies position PS, the single format processor module is installed in position 00 (preferred position) or in position 01, if position 00 is unavailable. Illustration the double format processor module is installed in positions 00 and 01 (preferred positions) or in positions 01 and 02, if position 00 is unavailable, z other modules are installed starting from position 01, 02 or 03 depending on the installation of the processor. z Illustration Using a double format power supply module: z z the power supply module automatically occupies position PS, the single format processor module is always installed in position 01. Illustration 96 35011052.06 07/2008 TSX RKY.. standard and extendable racks: functions z z the double format processor module is installed in positions 01 and 02, other modules are installed starting from position 02 or 03 depending on the type of processor. Illustration Installation on an extendable rack with address 0 and with an Atrium processor The PCX 57 processor, which is built in to the PC, occupies a virtual position on the rack with address 0. This virtual position should be unoccupied. Premium PLCs have two types of power supply (standard and double format), the unoccupied position will depend upon the type of power supply used. Using a standard format power supply module: the power supply module automatically occupies position PS, position 00, the virtual slot for the processor, must be unoccupied, z the other modules are installed starting at position 01. z z Illustration Using a double format power supply module: the power supply module automatically occupies the positions PS and 00, position 01, the virtual location of the processor, must be unoccupied, z the other modules are installed starting from position 02. z z Illustration 35011052.06 07/2008 97 TSX RKY.. standard and extendable racks: functions Installation on an extendable rack with address 1 to 7, regardless of processor type Each rack must be equipped with a power supply module, either standard or double format. Using a standard format power supply module: z z the power supply module automatically occupies position PS, the other modules are installed starting from position 00. Illustration Using a double format power supply module: z z the power supply module automatically occupies positions PS and 00, the other modules are installed starting at position 01. Illustration 98 35011052.06 07/2008 TSX RKY Racks: accessories 8 At a Glance Aim of this Chapter The aim of this chapter is to show the different accessories which go with TSX RKY.. racks.. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page TSX CBY..0K bus X extension cable (II ≥ 02) 100 TSX CBY 1000 bus X extension cable 103 Line terminator TSX TLYEX 105 Positioning of line terminators on a station using a Premium processor 106 Positioning of line termination on a station using a Atrium processor 107 TSX RKA 02 protective cover for unoccupied positions 108 Labeling 109 Compatibility with the Installed Base 111 99 TSX RKY Racks: accessories TSX CBY..0K bus X extension cable (II ≥ 02) At a Glance These cables of predetermined length are used to chain TSX RKY..EX extendable racks and to transport the different bus X signals. When a PCX 57 processor is used, they can also be used to connect the PC’s builtin processor and the first rack in the station. They are equipped at each end with male 9-pin SUB D connectors, which connect to the female 9-pin SUB D connector on the extendable rack or the PCX 57 processor. Station with a TSX processor capable of being integrated in the rack 100 35011052.06 07/2008 TSX RKY Racks: accessories Station with a PCX processor capable of being integrated in a PC Important: The cumulative length of all the cables used in a PLC station is limited to 100 meters (328 feet). CAUTION Insertion and extraction under power z Insertion and extraction of a TSX CBY0K cable must only be done with all the station’s elements switched off (racks, PC, etc.) Failure to follow these instructions can result in injury or equipment damage. CAUTION Minimum cable radius z The minimum bend radius of the bus X cable must be: z 40 mm (1.57 in) for a static application, z 80 mm (3.15 in) for a dynamic application. Failure to follow these instructions can result in injury or equipment damage. 35011052.06 07/2008 101 TSX RKY Racks: accessories Different cable types available 102 To suit different users, several cable lengths are available. Summary table of different cable types Product reference Lengths TSX CBY 010K (II ≥ 02) 1 meter TSX CBY 030K (II ≥ 02) 3 meters TSX CBY 050K (II ≥ 02) 5 meters TSX CBY 120K (II ≥ 02) 12 meters TSX CBY 180K (II ≥ 02) 18 meters TSX CBY 280K (II ≥ 02) 28 meters TSX CBY 380K (II ≥ 02) 38 meters TSX CBY 500K (II ≥ 02) 50 meters TSX CBY 720K (II ≥ 02) 72 meters TSX CBY 1000K (II ≥ 02) 100 meters 35011052.06 07/2008 TSX RKY Racks: accessories TSX CBY 1000 bus X extension cable At a Glance For bus X lengths less than 100 meters but different from those available as cables with connectors, always use a TSX CBY 1000 cable. This cable must have TSX CBY K9 connectors fitted at both ends by the user. The assembly procedure is described in the instructions supplied with the cable and the connectors. For implementation of these cables the following elements are required: 1 TSX CBY 1000 cable, 1 set of two TSX CBY K9 9-pin connectors, z 1 TSX CBY ACC10 kit. z z 1 TSX CBY 1000 cable, This cable must include one 100-meter reel of cable and two testers to check the cable once the various connections have been made. Illustration: Reel 1 set of two TSX CBY K9 9-pin connectors Testers For each connector this set must include: 1 connector body, 1 set of contacts, z 1 internal screening cap, z 1 external screening cap, z 1 ferrule, z 1 plastic cover with 2 fixing screws. z z Illustration: 35011052.06 07/2008 103 TSX RKY Racks: accessories 1 TSX CBY ACC10 kit This kit includes: z z 2 crimping tools, a contact extractor to be used in case of errors. Illustration: Crimping tools 104 35011052.06 07/2008 TSX RKY Racks: accessories Line terminator TSX TLYEX Introduction When extendable racks (see TSX RKY.. standard and extendable racks: functions, p. 85) are used, the bus X must be fitted with a line terminator at each end. At a Glance A line terminator is made up of a 9-pin SUB D connector and a cover containing the adaptation components. It is mounted on the 9-pin SUB D 9 connector belonging to the extendable rack at the end of the line. Illustration: TSX TLYEX line terminations are sold in twos and marked A/ and /B. The bus must be fitted with a terminator A/ at one end and a terminator /B at the other end in no predefined (see Positioning of line terminators on a station using a Premium processor, p. 106) order. CAUTION Insertion or extraction of terminator under power Insertion or extraction of a line terminator must only be done with all the station’s racks switched off. Failure to follow these instructions can result in injury or equipment damage. 35011052.06 07/2008 105 TSX RKY Racks: accessories Positioning of line terminators on a station using a Premium processor Positioning on a PLC station containing several TSX RKY..EX extendable racks Diagram showing the principle: Positioning on a PLC station containing a single TSX RKY..EX extendable rack Diagram showing the principle: Note: When a single extendable rack is used, a line terminator must always be mounted on each of the rack’s 9-pin SUB D connectors. 106 35011052.06 07/2008 TSX RKY Racks: accessories Positioning of line termination on a station using a Atrium processor At a Glance At manufacture, the equivalent of the line terminator /A is built in to the processor and, due to this, the processor forms a termination of the bus X. The extendable rack located at the end of the chain therefore must always have a TSX TLY EX line terminator labeled /B fitted on its unused 9-pin SUB D connector. Principle diagram: PC PCX57 OK NOK Special case. When no devices are connected to the bus X, the TSX TLYEX line terminator /B must be installed on the bus X connector of the PCX 57 processor. Illustration: PCX57 35011052.06 07/2008 OK NOK 107 TSX RKY Racks: accessories TSX RKA 02 protective cover for unoccupied positions At a Glance If a position on a rack is unoccupied, it is advisable to mount a TSX RKA 02 cover designed for this in this position. This cover is mounted and fixed on the rack like a module with a reduced depth. TSX RKA 02 covers are sold in indivisible quantities of five. Illustration 108 35011052.06 07/2008 TSX RKY Racks: accessories Labeling Labeling of module positions on the rack When the module is in place on the rack, it masks the address of the position, which is printed on the rack. Due to this and in order to be able to identify the module’s position quickly, each rack is delivered with a page of sticky labels which allow you to label the position of each module. This sticky label is stuck on the upper part of the module when it is in place on the rack. Illustration: example of processor module labeling Label position Page of labels: 35011052.06 07/2008 PS 00 01 020 03 04 05 06 07 08 09 10 11 12 13 14 109 TSX RKY Racks: accessories Rack labeling Each rack is delivered with a set of snap out labels so that for each rack you can label: z z the address of the rack in the station, the network address of the station when the station is connected to a communication network. Therefore each rack has two slots where these addresses can be placed. Illustration: Network address of the station Rack address in station 110 35011052.06 07/2008 TSX RKY Racks: accessories Compatibility with the Installed Base Summary Table This table shows the compatibility with the installed base in relation to old and new references: Configuration already in place with New references Previous references New references Development of the configuration Previous references TSX RKY..E TSX CBY..OK (•• 01) TSX TLY (•• 01) TSX RKY..E TSX CBY..OK (•• 01) TSX TLY A+B (•• 03) TSX RKY..E TSX CBY..OK (•• 02) TSX CBY 1000 TSX TLY A+B (•• 03) TSX RKY..EX TSX CBY..OK (•• 02) TSX CBY 1000 TSX TLYEX A/+/B 2 terminators TSX TLY (•• 01) YES NO (1) NO (1) NO (3) TSX CBY..OK cables (•• 01) YES YES NO (2) NO (4) Terminators TSX TLY A+B (•• 03) YES YES YES NO (3) TSX RKY..E rack(s) YES YES YES NO (5) TSX CBY..OK (•• 02) or CBY 1000 cable(s) YES YES YES YES TSX RKY..EX rack(s) NO (6) YES YES YES Terminators TSX TLYEX A/+/B YES YES YES YES Details of incompatibilities: 1. Operation correct but incorrect detection of bus X break. Behavior of outputs not guaranteed for bus break. 2. Correct operation for 50 instead of 100 meters. Correct detection of bus X break. 35011052.06 07/2008 111 TSX RKY Racks: accessories 3. Incorrect bus adaptation, no guarantee of operation. The TLY and TLY A/B adapt the signals in relation to 0V (wire in the bus X cable). The TLY EX A/B adapt the signals in relation to the shielding. 4. Incorrect detection of duplicate address. 5. Operation correct but no detection of duplicate address. 6. Incorrect bus adaptation. TLY EX plugs required for correct operation when a TSXRKY..EX. is used in the configuration. Note: In a PLC station, the TSX TLY line terminator torque must be of the same index. •• corresponds to the product version. 112 35011052.06 07/2008 Ventilation module 9 At a Glance Aim of this Chapter This Chapter deals with the ventilation module and its installation. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Ventilation module: general introduction 114 Ventilation module: physical description 116 Ventilation module: dimensions 117 Ventilation module: mounting 118 Rules for installing racks fitted with ventilation modules 120 Ventilation Module: Connections 121 Ventilation module: characteristics 123 113 Ventilation module Ventilation module: general introduction At a Glance The ventilation modules which are installed above the TSX P57/TSX H57 PLC station racks force air convection in order to make uniform the ambient temperature inside the casing and thus eliminate the various hot spots which may exist. Note: A temperature probe built into each module informs the user when the ambient temperature has reached its maximum value. ventilation module: Use of ventilation modules 114 The use of these modules is recommended in the following cases: Ambient temperature in the 25°C...60°C range: the life of the various components of the Premium PLC is increased (MTBF increased by 25%). z Ambient temperature in the 60°C...0.70°C range: the ambient temperature being limited to 60°C without ventilation, forced ventilation makes it possible to lower the temperature inside the modules by 10°C, which brings the internal temperature of the modules back to the equivalent of 60°C at ambient temperature. z 35011052.06 07/2008 Ventilation module Different module types Three ventilation modules are available, adapted to the main supply networks: ventilation module with 24 VDC, 110 VAC or 220 VAC power supply. According to the rack modularity (4, 6, 8 or 12 positions), 1, 2 or 3 ventilation modules are to be fitted above each rack: 12-position racks TSX RKY 12/12EX: 3 ventilation modules, 8-position racks TSX RKY 8/8EX: 2 ventilation modules, z 4 and 6-position racks TSX RKY 4EX/6/6EX: 1 ventilation module. z z Illustration: TSX RKY 12/12EX TSX RKY 8/8EX TSX RKY 4EX/6/6EX 35011052.06 07/2008 115 Ventilation module Ventilation module: physical description Illustration Descriptive diagram: Table of labels This table gives you descriptions according to the labels: Label 1 Description Terminal block for connecting: z the module power supply, z the supply for the temperature probe and the associated LED or pre- actuator. Each terminal can receive one 1.5 mm2 (14 AWG) wire without a wire end ferrule, or two 1 mm2 (16 AWG) wires with wire end ferrules. 116 2 Terminal for connecting the module to the ground. 3 Holes for fixing the module (M4 x 12 screws). If these modules are used with Premium PLCs, the ventilation modules must be fixed on an AM1-ED ... 35 x 15 mounting rail . 4 Louvered slats which send air to the front. 35011052.06 07/2008 Ventilation module Ventilation module: dimensions Ventilation module alone Illustrative diagram (dimensions in millimeters): Rear view Ventilation module + rack Right-hand view Front view Illustrative diagram (dimensions in millimeters): (1) with screw terminal block module, (2) maximum depth for all types of modules and their associated connectors. Characteristics table: 35011052.06 07/2008 Racks Number of positions a TSX RKY 4EX 4 187.9 mm TSX RKY 6/6EX 6 261.6 mm TSX RKY 8/8EX 8 335.3 mm TSX RKY 12/12EX 12 482.6 mm 117 Ventilation module Ventilation module: mounting General points The ventilation modules associated with Premium PLC’s must be mounted on 35mm wide and 15mm deep mounting rails (type AM1-ED...) in order to compensate for the thickness of the rack (see mounting and fixing racks, p. 81). Diagram: Support Mounting rail 35x15 Ventilation module Premium PLC 118 35011052.06 07/2008 Ventilation module Mounting position Mounting position for ventilation modules according to rack-type: 6 position racks (TSX RKY 6/6EX) 12 position racks (TSX RKY 12/12EX) 35011052.06 07/2008 8 position racks (TSX RKY 8/8EX) 4 position racks (TSX RKY 4EX) 119 Ventilation module Rules for installing racks fitted with ventilation modules Illustration Principle diagram: see Installing Racks, p. 78 a = 50 mm b = 30 mm 1 Installation or casing. 2 Trough or cable tray. 120 35011052.06 07/2008 Ventilation module Ventilation Module: Connections Connection of the Ventilation Module Power Supply Illustration: Note: When using several ventilation modules of the same type, use a common power supply for all the ventilation modules. 35011052.06 07/2008 121 Ventilation module Connection of the Temperature Probe Power Supply The Temperature probe may be supplied either by a direct current or alternating current and be connected to a LED indicator, a PLC input, etc. . Diagram: Direct current supply Alternating current supply Note: When using several ventilation modules, the probe contacts shall be serialized. Illustration: Ventilation module 1 Ventilation module 2 Ventilation module 3 (1) direct 24/28 V or alternating 110/220 V 122 35011052.06 07/2008 Ventilation module Ventilation module: characteristics Table of Characteristics Table of ventilation module characteristics: Reference TSX FAN D2 P TSX FAN A4P TSX FAN A5P Nominal 24 VDC 110 VAC 220 VAC Limit 20..27.6 VDC 90120 VAC 180260 VAC Current consumed at nominal voltage 180 mA 180 mA 100 mA Temperature probe direct 24/28 VDC or alternating 110/220 VAC Supply voltage Power supply voltage Outage 1 A at 24 VDC / 10,000 operations power (on 1 A at 48 VDC / 30,000 operations resistive load) 1 A at 110 VDC / 30,000 operations 0.5 A at 220 VDC / 10,000 operations Deactivation Temperature>= 75°C +/- 5°C Status 0.5 A at 220 VDC / 10,000 operations Temperature>= 75°C +/- 5°C No. of modules per rack z 1 module on 4 and 6-position racks (TSX RKY 4EX/6/6EX), z 2 modules on 8-position racks (TSX RKY 8/8EX), z 3 modules on 12-position racks (TSX RKY 12/12EX). 35011052.06 07/2008 123 Ventilation module 124 35011052.06 07/2008 X-Bus extension module 10 At a Glance Aim of this Chapter The aim of this Chapter is to introduce the X-Bus extension module and its installation. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Bus X extension module: introduction 126 Rack Extender Module: physical description 128 Bus X extension module: installation 129 Bus X extension module: configuration 133 Bus X extension module: maximum distances according to module type 134 Bus X extension modules: connections 138 Bus X extension module: diagnostics 140 Topology of a PLC station with extension module 142 Managing a power supply module fitted with an bus X extension module 144 125 X-Bus extension module Bus X extension module: introduction General The Premium PLC bus X makes it possible to connect 8 racks with 12 positions (TSX RKY 12EX) or 16 racks with 4, 6 or 8 positions (TSX RKY 4EX/6EX/8EX), distributed along a maximum length of 100 meters. If applications require greater distances between racks, the bus X extension module (TSX REY 200) makes it possible to greatly increase this distance whilst maintaining the characteristics and performance which are inherent in a PLC station which is only made up of a single bus X segment without extension module. The system consists of: an bus X extension module (TSX REY 200) called "Master" located on the rack with address 0 (rack supporting the processor) and on the main bus X segment. This module has two channels which allow the two bus X segments to be extended up to a maximum distance of 250 meters, z one or two TSX REY 200 modules called "Slave", each located on a rack on the extended bus segments, z each of the slave modules is connected to the master module by a TSX CBRY 2500 cable fitted with TSX CBRY K5 connectors. z 126 35011052.06 07/2008 X-Bus extension module Example of topology Illustration: Remote X bus segment Main X bus segment X bus Remote X Bus ≤ 100m TSX REY 200 Master ≤ 250m slave TSX REY 200 X ≤100m Processor ≤ 250m Remote X Bus TSX REY 200 slave X bus ≤ 100m Remote X bus segment Module consumption 35011052.06 07/2008 Consumption on 5VDC power supply: 500 mA Dissipated power: 2.5 W. 127 X-Bus extension module Rack Extender Module: physical description Illustration Descriptive diagram: Table of labels Description table according to number: Label 128 Description 1 Display block made up of 6 LEDs: z RUN LED: indicates the operating status of the module, z ERR LED: indicates an error within the module, z I/O LED: indicates an error external to the module, z MST LED: indicates the status of the master or slave function of the module, z CH0 LED: indicates the operating status of channel 0, z CH1 LED: indicates the operating status of channel 1, 2 Connector for linking channel 0 of the module. 3 Connector for linking channel 1 of the module. 35011052.06 07/2008 X-Bus extension module Bus X extension module: installation Introduction There are several different cases when installing an bus X extension module: installation of a master module on the TSX P57 station, installation of a master module on the PCX 57 station, z installation of a slave module. z z Installation of a master module on the TSX P57 station The master module must be installed: on the rack which supports the processor (rack with address 00), this rack being located on the main bus X segment, z in any position on this rack apart from those positions which are dedicated to the power supply and processor modules. z Constraint: the 00 position of rack with address 0 is prohibited to all modules including the processor module, only a double format power supply is allowed to occupy this position. The table below indicates the various scenarios according to the format of the power supply module and the processor: Scenario Illustration Rack with address 0 with single format power supply module and processor: z power supply module in position PS, z processor must be in position 01, z position 00 is always unoccupied, z TSX REY 200 module in one of the available positions in the rack. Rack with address 0 with double format power supply module and single format processor: z power supply module in positions PS and 00, z processor must be in position 01, z TSX REY 200 module in one of the available positions in the rack. 35011052.06 07/2008 129 X-Bus extension module Scenario Illustration Address rack 0 with single format power supply module and double format processor: z power supply module in position PS, z processor must be in positions 01 and 02, z position 00 is always unoccupied, z TSX REY 200 module in one of the available positions in the rack. Rack with address 0 with double format power supply module and processor: z power supply module in positions PS and 00, z processor must be in positions 01 and 02, z TSX REY 200 module in one of the available positions in the rack. 130 35011052.06 07/2008 X-Bus extension module Installing a master module on a PCX 57 station As with a TSX P57 station, the master module must be installed: on the rack which supports the processor virtually (rack with address 0), this rack being located on the main bus X segment, z in any position on this rack apart from the position dedicated to the power supply module and that which is virtually occupied by the processor. z Constraint: The 00 position of the rack with address 0 is prohibited to all modules, only a double format power supply module is allowed to occupy this position. The virtual position of the processor (unoccupied position) must always be position 01. The table below indicates the various scenarios according to the format of the power supply module and the processor: Scenario Illustration Rack with address 0 with single format power supply: z power supply module in position PS, z virtual position of the processor must be position 01 (position always unoccupied), z position 00 is always unoccupied, z TSX REY 200 module in one of the available positions in the rack. Rack with address 0 with double format power supply module: z power supply module in position PS, z virtual position of the processor must be position 01 (position always unoccupied), z TSX REY 200 module in one of the available positions in the rack. 35011052.06 07/2008 131 X-Bus extension module Installation of a slave module The slave module can be installed on one of the racks of the bus extension segment and in any position on this rack apart from the one which is dedicated to the power supply module. The table below indicates the various scenarios according to the format of the power supply module and the processor: Scenario Illustration Rack with address 0 with single format power supply: z power supply module in position PS, z TSX REY 200 module in one of the available positions in the rack. Rack with address 0 with double format power supply module: z power supply module in positions PS and 00, z TSX REY 200 module in one of the available positions in the rack. 132 35011052.06 07/2008 X-Bus extension module Bus X extension module: configuration General points The configuration of the module as a master or slave is automatic: if the module is installed on the rack with address 0, it will automatically be declared as master, z if the module is installed on a rack with an address other than 0, it will automatically be declared as slave. z Note: If 2 racks are declared at address 0, the master module must be located on the rack supporting the "low" module addresses, as indicated in the figure below. "Low" module addresses: z addresses 0 to 6 on TSX RKY 8EX, z addresses 0 to 4 on TSX RKY 6EX, z addresses 0 to 2 on rack TSX RKY 4EX, Illustration Example: 2 TSX RKY 8EX racks at address 0. Microswitch 4 located on the rack Note: If two racks are declared at address 0, the rack supporting the "high" address modules cannot receive a slave extension module. "High" address modules: z addresses 8 to 14 on rack TSX RKY 8EX, z addresses 8 to 12 on rack TSX RKY 6EX, z addresses 8 to 10 on rack TSX RKY 4EX. 35011052.06 07/2008 133 X-Bus extension module Bus X extension module: maximum distances according to module type General points The figure below summarizes the maximum distances authorized for the different bus X segments and bus X extensions: z z for each bus X segment (X1, X2 or X3): maximum length 100 meters, for each bus X extension (XD1 or XD2): maximum length 250 meters, Illustration: Main bus X segment (X2) Main bus X segment (X1) Remote bus X ≤ 250m XD1 Bus X Bus X ≤ 100m <= 100 m TSX REY 200 Slave Master TSX REY 200 Bus X ≤ 100m TSX REY 200 Slave Processor XD2 Remote bus X ≤ 250m Bus X ≤ 100m Main bus X segment (X3) Taking this into account, the maximum distance possible between the processor and the remote modules is 350 meters. This distance of 350 meters is only possible for single discrete input/output modules. The following illustrations indicate the restrictions in relation to module type. Note: Extension is prohibited for communication modules TSX SCY •••/TSX ETY•••/TSX IBY •••/TSX PBY •••. These modules must be located on the main segment of the bus X1 134 35011052.06 07/2008 X-Bus extension module Safety and single discrete I/O modules Illustration: ≤ 350m ≤ 250 Bus X ≤ 100m Single discrete I/O modules: TSX DEY.../TSX DSY... and TSX PAY… safety modules Exception: TSX DEY 16FK 35011052.06 07/2008 135 X-Bus extension module Mixed discrete I/ O, analog, applicationspecific and bus sensor/actuator modules Illustration: ≤ 175 m Modules: TSX DMY… discrete mixed and TSX DEY 16FK discrete single, TSX AEY.../TSX ASY... analog, TSX ISPY.../TSX CTY...TSX CAY.../TSX CFY…applications TSX SAY 100 bus sensors/actuators. Bus X ≤ 100m ≤ 175 m Note: for the following modules: z TSX DEY 16 FK with PV index≥ 06, z TSX DMY 28FK / 28RFK, z TSX AEY 810/1614, z TSX ASY 410 with PV index ≥ 11, z TSX ASY 800, z TSX CTY 2C z TSX CAY 22/42/33, maximum distance authorized (extension cable and bus X cable length): 225 meters. 136 35011052.06 07/2008 X-Bus extension module Communication modules CAUTION Specific modules on extension prohibited The following modules must be located on the main bus X segment. z TSX SCY... communication z TSX ETY... network z TSX IBY... /TSX PBY field bus Do not locate them on bus X extensions Failure to follow these instructions can result in injury or equipment damage. Illustration: Modules: TSX SCY… communication TSX ETY... network TSX IBY…/TSX PBY field bus NO Extension prohibited! 35011052.06 07/2008 137 X-Bus extension module Bus X extension modules: connections General points To extend the bus X, you must use: z z the kit TSX CBRY 2500 made up of a reel of cable, 250 meters in length, the set of connectors TSX CBRY K5. You must fit the cable with connectors at both ends. The procedure for mounting the connectors on the cable is described in the instructions supplied with the set of connectors TSX CBRT K5. Connecting accessories Installing an bus X extension requires, therefore, the following elements: 1 TSX CBRY 2500 kit including 1 cable, 250 meters long, supplied on a reel. 1 set of 5 connectors TSX CBRY K5, which allows you to fit 2 extension cables, leaving you with one connector as a spare. 138 35011052.06 07/2008 X-Bus extension module Connecting principles Illustration: Main bus X segment Remote bus X segment Channel 0 Remote bus X (XD2) ≤ 250m TSX REY 200 Master TSX CBRY 2500+TSX CBRY K5 (Cable + connector) Channel 0 TSX REY 200 Slave Channel 1 Channel 0 TSX REY 200 Slave Processor Remote bus X (XD2) ≤ 250m TSX CBRY 2500+TSX CBRY K5 (Cable + connector) Remote bus X segment Note: Each bus X segment must have a A/ and B/ line terminator (see Line terminator TSX TLYEX, p. 105)at each end. 35011052.06 07/2008 139 X-Bus extension module Bus X extension module: diagnostics By signaling LEDs The TSX REY 200 module display panel, located on the front panel of the module, is used for diagnostics on the extension system. Illustration: display panel Module functioning as master (positioned on the rack with address 00) Diagnostics table: LED status Module status Comments ERR RUN Mst I/O CH0 CH1 F N/A N/A N/A N/A N/A Fault No communication with the processor Off On On Off On Off OK Channel 0 active Channel 1 inactive Off On On Off Off On OK Channel 0 inactive Channel 1 active Off On On Off On On OK Channel 0 active Channel 1 active Off On On On Off Off Fault Channel 0 inactive Channel 1 inactive Legend: On: on Off: switched off F: flashing N/A: Not applicable 140 35011052.06 07/2008 X-Bus extension module Module functioning as slave (positioned on a rack with address other than 00) Diagnostics table: LED status Module status Comments ERR RUN Mst I/O CH0 CH1 F N/A N/A N/A N/A N/A Fault No communication with the processors Off On Off Off On Off OK Channel 0 active Off On Off On Off Off Fault Channel 0 inactive Legend: On: on Off: switched off F: flashing N/A: not determined 35011052.06 07/2008 141 X-Bus extension module Topology of a PLC station with extension module TSX P57 station Illustration: Main bus X segment Segment 1 of remote bus X Bus X Remote bus X ≤ 250 m ≤ 100m TSX REY 200 Master TSX REY 200 Slave Bus X ≤ 100m TSX REY 200 Slave Processor Remote bus X ≤ 250 m Bus X ≤ 100m Segment 2 of remote bus X Maximum station capacity: With TSX P57 10 processors: z 2 TSX RKY 12 EX racks, z 4 TSX RKY 4EX/6EX/8EX racks. z With TSX P57 20/30/40 processors: z 8 TSX RKY 12 EX racks, z 16 TSX RKY 4EX/6EX/8EX racks. z 142 35011052.06 07/2008 X-Bus extension module PCX 57 station Illustration: Main bus X segment Segment 1 of remote bus X Bus X Remote bus X ≤ (250m-X1) Host PC ≤ 100m TSX REY 200 TSX REY 200 Slave Master PCX 57 processor Bus X Bus X L = L=X1 TSX REY 200 Virtual position of the processor Remote bus X ≤ (250m-X1) Slave Bus X ≤ 100m Segment 2 of remote bus X Main bus X segment Maximum station capacity: With TSX P57 10 processors: z 2 TSX RKY 12 EX racks, z 4 TSX RKY 4EX/6EX/8EX racks. z With TSX P57 30 processors: z 8 TSX RKY 12 EX racks, z 16 TSX RKY 4EX/6EX/8EX racks. z Note: In every case, the length of bus X extension segments is defined in relation to the location of the processor. This maximum distance is 250 meters (820 feet). In the special case of the PCX 57 processor, when it is located in the PC, the extension distance of the bus X segments in relation to the rack with address 0, is equal to 250 meters minus the distance (X1) between the processor and rack with address 0. Main bus X segment = (X1+X2) ≤ 100 meters (328 feet). 35011052.06 07/2008 143 X-Bus extension module Managing a power supply module fitted with an bus X extension module General CAUTION Use of a extension module If an bus X extension module (TSX REY 200) is used in an instalation, all the racks configured in the application must be connected, powered and functioning when managing the software application. Failure to follow these instructions can result in injury or equipment damage. Note: All use of an bux X extension module (TSX REY 200) in an installation makes management of the installation or the machine subject to all the racks configured in the application being present. In order to do this, an application check must be carried out to make sure that all the application racks are present by testing the bit %MWxy MOD 2 X6 (explicit exchanges) on at least one module on each rack. This test allows the racks to be cleared of all incorrect declarations in the rack addressing and, in particular, if two racks bear the same address by mistake. This test only comes into play after the installation has completely restarted (switched on, installation modified, processor RESET, configuration changed). 144 35011052.06 07/2008 TSX P57/TSX H57 Premium processors III At a Glance Subject of this Part 35011052.06 07/2008 The aim of this part is to describe the Premium TSX P57/TSX H57 processors and their installation. 145 TSX P57/TSX H57 Premium processors What's in this Part? 146 This part contains the following chapters: Chapter Chapter Name Page 11 TSX P57/TSX H57 processors: introduction 147 12 TSX P57/TSX H57 processors: installation 157 13 TSX P57/TSX H57 processors: diagnostics 177 14 TSX P57 103 processor 211 15 TSX P57 153 processor 213 16 TSX P57 203 processor 215 17 TSX P57 253 processor 217 18 TSX P57 2623 processor 219 19 TSX P57 2823 processor 223 20 TSX P57 303 processor 227 21 TSX P57 303A processor 229 22 TSX P57 353 processor 233 23 TSX P57 353A processor 235 24 TSX P57 353LA Processor 239 25 TSX P57 3623 processor 243 26 TSX P57 3623A processor 247 27 TSX P57 453 processor 251 28 TSX P57 453A processor 253 29 TSX P57 4823 processor 257 30 TSX P57 4823A processor 261 31 Premium TSX P57/TSX H57 processor: general characteristics 265 32 Processor performance 271 35011052.06 07/2008 TSX P57/TSX H57 processors: introduction 11 At a Glance Aim of this Chapter The aim of this chapter is to introduce the TSX P57/TSX H57 processors. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page General Introduction 148 Physical Description of TSX P57 Processors 150 Real-time clock 153 147 TSX P57/TSX H57 processors: introduction General Introduction Introduction A wide range of TSX P57 processors of different levels of performance and specifications are available to meet your various requirements. General Points TSX P57 sequential processors can be integrated into TSX RKY... racks (see Standard and extendable TSX RKY racks, p. 68). List of TSX P57 processors: TSX P57 103, TSX P57 153, TSX P57 203, TSX P57 253, TSX P57 2623, TSX P57 2823, z TSX P57 303, TSX P57 303A, TSX P57 353, TSX P57 353LA, TSX P57 353A, TSX P57 3623, TSX P57 3623A, z TSX P57 453, TSX P57 453A, TSX P57 4823, TSX P57 4823A. z z Note: Processors from families 20, 30 and 40 have built-in process control functions. Illustration 148 TSX P57 standard format in TSX RKY 6EX rack: 35011052.06 07/2008 TSX P57/TSX H57 processors: introduction Functions Premium TSX P57 processors manage a complete PLC station which is made up of: discrete input/output modules, analog input/output modules, z application-specific modules (i.e. counting, axis control, step by step control, communication, etc.), z z which can be distributed over one or more racks connected to the bus X. The application is designed using PL7 Junior or PL7 Pro running Windows. This offers: four programming languages: Grafcet, Ladder, Structured Text and List, a multitask software structure: Master, Fast, Event processing, z a change function for programs being executed, z etc. z z Table of TSX P57 Processors All processors in the TSX P57 range can be found in the following table. Type Physical format Maximum number of discrete I/Os Maximum memory size Built-in master FIPIO link Built-in Ethernet link TSX P57 103 Single 512 96K16 - - TSX P57 153 Single 512 96K16 X - TSX P57 353LA Single 1024 96K16 X - TSX P57 203 Double 1024 208K16 - - TSX P57 253 Double 1024 224K16 X - TSX P57 2623 Double 1024 208K16 - X TSX P57 2823 Double 1024 224K16 X X TSX P57 303/303A Double 1024 464K16 - - TSX P57 353/353A Double 1024 480K16 X - TSX P57 3623/ 3623A Double 1024 464K16 - X TSX P57 453/453A Double 2048 688K16 X - TSX P57 4823/ 4823A Double 2048 688K16 X X Legend: X: available. -: unavailable. 35011052.06 07/2008 149 TSX P57/TSX H57 processors: introduction Physical Description of TSX P57 Processors Illustration These diagrams label the different components of a TSX P57 processor module in standard format: 1 2 3 4 5 6 7 Standard format processor: TSX P57 103 / 153 150 Standard format processor: TSX P57 353LA 35011052.06 07/2008 TSX P57/TSX H57 processors: introduction These diagrams label the different components of a TSX P57 processor module in double format: 9 1 2 3 4 8 5 6 7 Double format processor: TSX P57 203/253/303/303A/353 TSX P57 353A/453/453A 35011052.06 07/2008 Double format processors with on-board Ethernet: TSX P57 2623/2823/3623/3623A/ 4823/4823A 151 TSX P57/TSX H57 processors: introduction Description This table describes the components of a processor module Number Function 1 Display panel containing four or five LEDs. 2 Recessed RESET button which when pressed causes a cold startup. z Processor working normally: cold startup in STOP or RUN mode, depending on the procedure defined at configuration. z Processor error: forced startup in STOP mode. 3 Terminal port (TER Connector (8-pin mini-DIN)): this is used to connect an FTX type or PC compatible terminal, or to connect the PLC to the UNI-TELWAY bus through the TSX P ACC 01 insulation unit. This connector is used to supply 5V to the peripheral which is linked to it (limited by the available current provided by the power supply). 4 Terminal port (AUX Connector (8-pin mini-DIN)): this is used to connect a peripheral with its own power supply (terminal, operator dialog console or printer (no voltage is supplied to this connector)). 5 Slot for a type 1 PCMCIA memory extension card. If there is no memory card, this slot is fitted with a cover which must be kept in place; as the processor will stop if it is removed. 6 Slot for a type 3 PCMCIA card. This slot can accept either of the following: z a memory extension card, z a communication card allowing the processor to be connected to a FIPWAY, FIPIO Agent, UNI-TELWAY or serial link communication channel. If there is no card, this slot is fitted with a cover. 7 9-pin SUB D connector for connecting a FIPIO bus master. This connector is only present on TSX P57 •53 processors. 8 RJ 45 connector for connecting to the Ethernet network. This connector is only present on TSX P57 •23 processors. 9 The ETY PORT display panel comprising 6 LEDs. Note: The (TER) and (AUX) connectors propose master UNI-TELWAY communication mode at 19200 bauds by default and can be configured for slave UNI-TELWAY or ASCII character mode. 152 35011052.06 07/2008 TSX P57/TSX H57 processors: introduction Real-time clock At a Glance Each processor (TSX P57 or PCX 57) has a savable real-time clock which manages: z z the current date and time, the date and time of when the application last stopped. The date and time are managed even when the processor is switched off, on condition that: the TSX P57 processor is mounted on the rack with its power supply module in place and is equipped with a back-up battery, z the PCX 57 processor is equipped with a back-up battery. z Current date and time the processor keeps the current date and time up to date in the system words %SW49 to %SW53. This data is coded in BCD. System words Most significant byte Least significant byte %SW49 00 Days of the week from 1 to 7 (1 for Monday and 7 for Sunday) %SW50 Seconds (0 to 59) 00 %SW51 Hours (0 to 23) Minutes (0 to 59) %SW52 Month (1 to 12) Days of the month (1 to 31) %SW53 Century (0 to 99) Year (0 to 99) Note: %SW49 is read-only. 35011052.06 07/2008 153 TSX P57/TSX H57 processors: introduction Accessing the date and time The date and time can be accessed: z z via the processor debug screen, via the program: z read: system words %SW49 to %SW53, if the system bit %S50 = 0, z immediate update: write system words %SW50 to %SW53, if the system bit %S50 = 1, z incremental update: the system word %SW59 is used to change the date and time, field by field, from the current value, if the system bit %S59 = 1, or is used to carry out a global increment/decrement. Bit value table: bit0 = 1 globally increments of the days of bit8 = 1 globally decrements of the days of the the week from 1 to 7 (1 for Monday 7 for week from 1 to 7 (1 for Monday 7 for Sunday) Sunday) bit1 =1, increments the seconds bit9 =1, decrements the seconds bit2 =1, increments the minutes bit10 =1, decrements the minutes bit3 =1, increments the hours bit11 =1, decrements the hours bit4 =1, increments the days bit12 =1, decrements the days bit5 =1, increments the months bit13 =1, decrements the months bit6 =1, increments the years bit14 =1, decrements the years bit7 =1, increments the centuries bit15 =1, decrements the centuries (1) all fields are updated. Note: The processor does not automatically manage the change between winter and summer time. 154 35011052.06 07/2008 TSX P57/TSX H57 processors: introduction The date and time of when the application last stopped The date and time of when the application last stopped are stored in BCD in the system words %SW54 to %SW58. System words Most significant byte Least significant byte %SW54 Seconds (0 to 59) 00 %SW55 Hours (0 to 23) Minutes (0 to 59) %SW56 Month (1 to 12) Days of the month (1 to 31) %SW57 Century (0 to 99) Year (0 to 99) %SW58 Day of the week (from 1 to 7) Reason for the last application stop to access the date and time of the last application stop: read the system words %SW54 to %SW58, z to find the reason for the last application stop: read the least significant byte of the system word %SW58 (value saved in BCD). z Table of %SW58 system words: 35011052.06 07/2008 %SW58 = 1 application switched to STOP mode, %SW58 = 2 application stopped due to a software error, %SW58 = 4 power outage or power supply RESET button has been pressed %SW58 = 5 stop due to hardware fault %SW58 = 6 application stopped due to HALT instruction 155 TSX P57/TSX H57 processors: introduction 156 35011052.06 07/2008 TSX P57/TSX H57 processors: installation 12 At a Glance Aim of this Chapter This Chapter deals with the installation of TSX P57/TSX H57 processor modules and the PCMCIA extension card. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Positioning of the processor module 158 How to mount processor modules 161 Mounting/Removing a PCMCIA Memory Extension Card on a TSX P57 Processor 164 Processing on Insertion/Extraction of a PCMCIA Memory Card on a Premium PLC 167 Standard and Backup Memory Cards for PLCs 168 Application + Files Type Memory Cards 171 File Type Memory Card: TSX MRP F 004M Replaces Card TSX MRP DS 2048 P 174 Correspondence Table 175 157 TSX P57/TSX H57 processors: installation Positioning of the processor module Introduction You may face two possible scenarios when positioning a processor module on a rack: z z 158 positioning of a standard format processor module, positioning of a double format processor module. 35011052.06 07/2008 TSX P57/TSX H57 processors: installation Positioning of a standard format processor module A standard format processor module is always installed on the TSX RKY.. rack with address 0 and in position 00 or 01 depending on whether the rack is equipped with a standard format or double format supply module. Rack with standard format supply module: TSX PSY 2600/1610. In this case, the processor module shall be installed in position 00 (preferred position) or position 01, in the latter case, position 00 should not be occupied. Illustration Rack with double format supply module: TSX PSY 3610/5500/5520/8500. In this case, as the supply module occupies two positions (PS and 00), the processor shall be installed in position 01. Illustration Note: If the CPU is intended to replace an ATRIUM module in your PLC configuration, make sure that the surplus electrical consumption on the rack which is caused by this modification does not lead to the replacement of your power supply module by a more powerful module. 35011052.06 07/2008 159 TSX P57/TSX H57 processors: installation Positioning of a double format processor module A double format processor module is always installed on the TSX RKY.. rack with address 0 and in position 00 and 01 or 01 and 02 depending on whether the rack is equipped with a standard format or double format supply module. Rack with standard format supply module: TSX PSY 2600/1610 . In this case, the processor module shall be installed in position 00 and 01 (preferred position) or position 01 and 02, in the latter case, position 00 should not be occupied. Illustration Rack with double format supply module: TSX PSY 3610/5500/5520/8500 . In this case, as the supply module occupies two positions (PS and 00), the processor shall be installed in position 01 and 02. Illustration Note: The rack on which the processor is installed always has the address 0. 160 35011052.06 07/2008 TSX P57/TSX H57 processors: installation How to mount processor modules Introduction CAUTION Mounting or removing processor when powered Do not mount or remove processor modules with power switch on Failure to follow these instructions can result in injury or equipment damage. Note: Mounting and removing processor modules is otherwise identical to mounting and removing other modules. when extracting/inserting modules with the power on, the terminal block or HE10 connector must be disconnected. You must also take care to shut off the sensor/ pre-actuator supply. 35011052.06 07/2008 161 TSX P57/TSX H57 processors: installation Installing a processor module onto a rack Carry out the following steps: Step Action Illustration 1 Place the pins at the back of the module into the centering holes on the lower part of the rack (number 1, see diagram 1). 2 Swivel the module to bring it into contact with the rack (number 2). 3 Fix the processor module to the rack by tightening the screw on the upper part of the module (number 3). Note: the mounting of processor modules is identical to the mounting of other modules. Note: Maximum tightening torque: 2.0 Nm (1.5 lb. ft.) CAUTION Mounting processor when powered A processor module must always be mounted with the rack power supply switched off. Failure to follow these instructions can result in injury or equipment damage. 162 35011052.06 07/2008 TSX P57/TSX H57 processors: installation Grounding modules Processor modules are grounded using metal plates at the rear of the module. When the module is in place, these metal plates are in contact with the metal of the rack. This ensures the link with the ground connection. Illustration Ground connection contacts 35011052.06 07/2008 163 TSX P57/TSX H57 processors: installation Mounting/Removing a PCMCIA Memory Extension Card on a TSX P57 Processor Introduction A clip is needed to insert a PCMCIA memory card into its slot on the TSX P57 processor. Position of the PCMCIA Cards in the Processors The following table describes the possible slots for the different types of PCMCIA cards in the PLC processors: Mounting of the Card in the Clip PCMCIA card Slot A (top) Slot B (bottom) Standard: TSX MRPP• and MFPP• Yes No Application and Files: TSX MRPC• and MCPC• Yes No Data or Files: TSX MRPF• Yes Yes For TSX P57 1•3 to TSX P57 4•3 Premium PLCs, the memory cards (*) are mounted in the clip as follows: Step 1 2 Action Place the end of the memory card (opposite end to the connector) between the arms of the clip. The markers (in the form of a triangle) on both the clip and the card label must be facing same way. Slide the memory card into the clip until it stops. The card is now firmly attached to the clip. Illustration markers locating device with one edge connector markers locating device with 2 edges clip (*) Note: This mounting procedure is only for TSX MRPF data or file-type cards. See mounting procedure below. 164 35011052.06 07/2008 TSX P57/TSX H57 processors: installation Mounting of the TSX MRP F• Card in the Extractor Step 1 2 For TSX P57 1•3 to TSX P57 4•3 Premium PLCs, the TSX MRP F• memory cards inserted in slot B (bottom) are mounted in the extractor as follows: Action Illustration Card with a PV ≤ 03 (1) Illustration Card with a PV > 03 (1) Guide the memory card into the extractor from an oblique angle, placing the 2 pins on the card into the 2 grooves on the extractor. pin pin Click! Click! Swivel the extractor on the card until it is fully locked. Legend (1) : the Product Version (PV) is shown on the label affixed to the PCMCIA card. 35011052.06 07/2008 165 TSX P57/TSX H57 processors: installation Mounting of the Memory Card in the PLC Carry out the following steps to install the memory card into the processor: Step Action 1 Remove the protective cover by unlocking it and then pulling it forwards out of the PLC. 2 Place the PCMCIA card fitted with its clip into the opened slot. Slide the whole thing in until the card can go no further, then press the clip to connect the card. Example: Position of the card in slot A for TSX 57 1•3 to 4•3. Note: For TSX 57 1•3\2•3\3•3\4•3 processors, check that the mechanical locating devices are positioned correctly: z 1 edge on top, z 2 edges at the bottom. For TSX 57 5•3 processors, two guides allow that the PCMCIA card is correctly positioned in its slot. Note: If the program contained in the PCMCIA memory card contains the RUN AUTO option, the processor will automatically restart in RUN mode after the card has been inserted. 166 35011052.06 07/2008 TSX P57/TSX H57 processors: installation Processing on Insertion/Extraction of a PCMCIA Memory Card on a Premium PLC General CAUTION Operation without cover The front panels of Premium PLC processors have removable covers to prevent the accidental intrusion of objects which could damage the connector. It is essential to leave the covers in place when no card is inserted in these slots. Failure to follow these instructions can result in injury or equipment damage. TSX P57 1•3 to 4•3 PLCs Memory cards located in slot A (top) The extraction (or absence) of the cover or memory card and clip causes the PLC to stop without saving the application context. Module outputs switch to fallback mode. Inserting the cover or memory card with clip will cause the PLC to perform a cold start. DANGER Unexpected equipment operation If the program contained in the PCMCIA memory card includes the RUN AUTO option, the processor will automatically restart in RUN after the card is inserted. Ensure work area is clear before applying power. Failure to follow these instructions will result in death or serious injury. Memory cards located in slot B (bottom) The PCMCIA memory card should be inserted into slot B of the processor while the PLC power is off. Ignoring this requirement could cause the processor to malfunction. 35011052.06 07/2008 167 TSX P57/TSX H57 processors: installation Standard and Backup Memory Cards for PLCs Standard Memory Cards There are 3 types of standard memory cards: Saved RAM memory extension cards. Flash Eprom memory extension cards. z Flash Eprom Backup memory cards. z z Saved RAM memory extension cards: used particularly when generating and debugging an application program. They are used for all application transfer and modification services when online. The memory is saved by a removable battery integrated in the memory card. Flash Eprom memory extension cards: used when the application program debugging has finished. It allows only a global transfer of the application and avoids the problems associated with battery backups. Flash Eprom Backup memory cards: used to save the project from the controller’s internal RAM to the Backup Flash Eprom card. The internal RAM memory can thus be reloaded using the contents of the Backup Flash Eprom card without having to use a terminal. WARNING write protection switch operation with power on It is essential that any modification of the position of the PCMCIA card write protection switch be performed when the controller is powered down. Failure to follow these instructions can result in death, serious injury, or equipment damage. 168 35011052.06 07/2008 TSX P57/TSX H57 processors: installation Product References for Standard and Flash Eprom Extension Memory Cards References The following table shows the compatibility of the cards with the processors: Type/Capacity Processor compatibility TSX P57 1•3 TSX P57 2•3/2•23 PCX 57 2•3 TSX P57 3•3/3•3A/353LA/3623/ 3623A TSX P57 4•3/4•3A/4823/4823A PCX 57 353 TSX MRP P 128K (1) TSX MRP 032P RAM/32K16 Yes Yes Yes TSX MRP P 224K (1) TSX MRP 064P RAM/64K16 Yes Yes Yes TSX MRP C 448K (1) TSX MRP 0128P RAM/128K16 No Yes Yes TSX MRP C 001M (1) TSX MRP 0256P RAM/256K16 No Yes Yes TSX MRP C 003M (1) TSX MRP 0512P RAM/512K16 No Yes Yes TSX MFP P 128K (1) TSX MFP 032P Flash Eprom/ 32K16 Yes Yes Yes TSX MFP P 224K (1) TSX MFP 064P Flash Eprom/ 64K16 Yes Yes Yes TSX MFP 064 P2 TSX MFP 064P Flash Eprom/ 64K16 Yes (2) Yes (2) Yes (2) TSX MFP P 384K (1) TSX MFP 0128P Flash Eprom/ 128K16 No Yes Yes TSX MFP 0128 P2 TSX MFP 0128P Flash Eprom/ 128K16 No Yes (2) Yes (2) TSX MFP P 001M Flash Eprom/ 256K16 Flash Eprom/ 384K16 (3) Flash Eprom/ 512K16 (4) No Yes Yes Legend TSX M•• • •••K new references to replace the old TSX M•P •••P type references. 35011052.06 07/2008 169 TSX P57/TSX H57 processors: installation (2) The application found on the TSX MFP* ****2 card can only be read if the card is in a processor version < 6.1. If the card is in a processor version ≥ 6.1, the card application is available in read and write mode. (3) 384 K16 are only available for TSX P57 3•3M and TSX P57 3•3AM processors. (4) 512 K16 are only available for TSX P57 4•3M processors. Note: Memory capacity: K16= K words (16-bit word). Product References for Backup Extension Memory Cards References TSX MFP B 096K (1) TSX MFP BAK032P The following table shows the compatibility of the cards with the processors: Type/Capacity BACKUP/32K16 Processor compatibility TSX P57 103 TSX P57 2•3/2•23 PCX 57 2•3 TSX P57 3•3/3•3A/353LA/3623/ 3623A TSX P57 4•3/4•3A/4823/4823A PCX 57 353 Yes Yes Yes Legend TSX MFP B 096K new references to replace the old TSX MFP BAK032P type references. Note: Memory capacity: K16= K words (16-bit word). 170 35011052.06 07/2008 TSX P57/TSX H57 processors: installation Application + Files Type Memory Cards Application + Files Type Memory Extension Cards In addition to the conventional application storage area (program + constants), these memory cards also have a file area for archiving/restoring the data by program. Application examples: z z automatic storage of application data and remote consultation by modem link, storage of manufacturing formulas. There are two types of memory card: saved RAM memory extension cards: application + files. The memory is saved by a removable battery built into the memory card, z Flash Eprom memory extension card: application + files. In this instance, the data storage area is in saved RAM which implies that this type of card must be equipped with a back-up battery. z WARNING Write protection switch operation with power on It is essential that any modification of the position of the PCMCIA card write protection switch be performed when the controller is powered down. Failure to follow these instructions can result in death, serious injury, or equipment damage. Cards for Harsh Environments 35011052.06 07/2008 Three cards have been developed especially for use in harsh environments. These are the TSX MRP C 001MC, TSX MRP C 003MC, TSX MRP C 007MC whose characteristics are identical to the TSX MRP C 001M, TSX MRP C 003M, TSX MRP C 007M. 171 TSX P57/TSX H57 processors: installation Product References for Application + Files Extension Memory Cards References The following table shows the compatibility of the cards with the processors: Technology Type/Capacity type Application File zone zone (RAM type) Processor compatibility Symbol area (RAM type) TSX P57 1•3 TSX P57 TSX P57 2•3/2•23 3•3/ 3•3A/ 3623/ 3623A TSX P57 453/ 453A/ 4823/ 4823A TSX MRP C 448K (1) TSX MRP 232 P RAM 32K16 128K16 - yes yes yes yes TSX MRP C 384K (1) TSX MRP 264 P RAM 64K16 128K16 - yes yes yes yes TSX MRP C 768K (1) TSX MRP 2128 P RAM 128K16 128K16 128K16 no yes yes yes TSX MRP C 01M7 RAM (1) TSX MRP 3256 P 256K16 640K16 128K16 (5x128K1 6) no yes (2) yes yes TSX MRP C 002M RAM (1) TSX MRP 3384 P 384K16 640K16 - no yes (2) yes yes TSX MRP C 003M RAM (1) TSX MRP 0512 P 512K16 - 256K16 no yes (2) yes (3) yes TSX MRPC 007M RAM 960K16 384K16 640K16 no no no yes (4) TSX MCP C 224K (1) TSX MFP 232 P Flash EPROM 32K16 128K16 - yes yes yes yes TSX MCP C 224K (1) TSX MFP 264 P Flash Eprom 64K16 128K16 - yes yes yes yes 172 35011052.06 07/2008 TSX P57/TSX H57 processors: installation Legend TSX M•• C •••• new references to replace the old TSX M•P •••P type references. (2) The usable application size is limited to 160K16 which conforms to the characteristics of this processor. (3) The usable application size is limited to 384K16 which conforms to the characteristics of this processor, the size of the symbol area is limited to 120K16. (4) Reserved. Note: For the TSX MRPC 007M, the 960K16 application area is divided into 2*480K16: z 480K16 for the executable code, z 480K16 for comments and graphic information. 35011052.06 07/2008 173 TSX P57/TSX H57 processors: installation File Type Memory Card: TSX MRP F 004M Replaces Card TSX MRP DS 2048 P At a Glance This card is used for archiving application data. Application examples: z z storage of manufacturing formulas, making a library. The TSX MRP F 004M card has a Saved RAM capacity of 4 Mb. Saving is carried out by a removable battery built into the memory card. Compatibility The TSX MRP F 004M memory card must be used in one of the following processors: TSX P57 203 and TSX P57 2623, TSX P57 253 and TSX P57 2823, z TSX P57 303/303A and TSX P57 3623/3623A, z TSX P57 353/353A/353LA, z TSX P57 453/453A and TSX P57 4823/4823A. z z 174 35011052.06 07/2008 TSX P57/TSX H57 processors: installation Correspondence Table At a Glance Depending on the type of memory card the characteristics are detailed: See Standard Memory Cards, p. 168, See Product References for Backup Extension Memory Cards, p. 170, z See Application + Files Type Memory Cards, p. 171, z See File Type Memory Card: TSX MRP F 004M Replaces Card TSX MRP DS 2048 P, p. 174. z z Table The following table gives the correspondence between the references of the old cards and the new references, depending on the type of card: Memory card type: Old reference New reference Standard and Flash Eprom TSX MRP 032P TSX MRP P 128K Backup Application + Files File 35011052.06 07/2008 TSX MRP 064P TSX MRP P 224K TSX MRP 0128P TSX MRP C 448K TSX MRP 0256P TSX MRP C 001M TSX MRP 0512P TSX MRP C 003M TSX MFP 032P TSX MFP P 128K TSX MFP 064P TSX MFP P 224K/ TSX MFP 064 P2 TSX MFP 0128P TSX MFP P 384K/ TSX MFP 0128 P2 TSX MFP BAK032P TSX MFP B 096K TSX MRP 232 P TSX MRP C 448K TSX MRP 264 P TSX MRP C 384K TSX MRP 2128 P TSX MRP C 768K TSX MRP 3256 P TSX MRP C 01M7 TSX MRP 3384 P TSX MRP C 002M TSX MRP 0512 P TSX MRP C 003M TSX MRPC 007M TSX MRPC 007M TSX MFP 232 P TSX MCP C 224K TSX MFP 264 P TSX MCP C 224K TSX MRP DS 2048 P TSX MRP F 004M 175 TSX P57/TSX H57 processors: installation 176 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics 13 At a Glance Aim of this Chapter This Chapter deals with diagnostics for TSX P57/TSX H57 processors. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Viewing 178 Precautions to be taken when replacing a TSX P57/TSX H57 processor 181 Changing the RAM memory backup battery on TSX P57 182 Changing the Battery of a RAM Memory PCMCIA Card on the TSX P57 185 Changing the Battery of a TSX MRP DS 2048 P RAM Memory Card 187 Changing the Batteries of a PCMCIA Memory Card 189 Battery Lifetimes for the PCMCIA Memory Card 193 What happens after you press the processor RESET button 204 Finding errors using processor state LEDs 205 Non blocking errors 206 Blocking errors 208 Processor or system errors 209 177 TSX P57/TSX H57 processors: diagnostics Viewing At a Glance There are five display LEDs on the front panel of the processor for a quick diagnostic of the status of the PLC controller. Illustration 178 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Description The following table describes the role of each LED LED flashing LED on. LED off. LED status not important RUN (green) ERR (red) I/O (red) TER (yellow) FIP (yellow) Description self-testing in progress. reset (for processor versions ≥4.0). reset (for processors version <4.0). blocking software fault. fault on Bus X (for processor versions ≥4.0). fault on Bus X (for processor version <4.0). hardware fault or fault on BusX. In this case, do a reset. If the three LEDs are still on after the reset, then it is a hardware fault. PLC working normally, run the program. processor or system fault I/O fault from a module or channel or a configuration error. terminal port link active. The intensity of the flashing depends on the traffic. FIPIO bus link active. The intensity of the flashing depends on the traffic. PLC not configured (application absent, not valid or incompatible). normal state, no internal fault. 35011052.06 07/2008 179 TSX P57/TSX H57 processors: diagnostics RUN (green) ERR (red) I/O (red) TER (yellow) FIP (yellow) Description normal state, no I/O fault. inactive link. inactive link. Note: z the FIP LED is only present on TSX P57 •53 and TSX P57 •823 processors. 180 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Precautions to be taken when replacing a TSX P57/TSX H57 processor Important DANGER Unexpected equipment operation If the TSX P57 processor is being replaced by another processor which is not blank (the processor has already been programmed and contains an application), the power for all the PLC station’s control units must be switched off. Before restoring power to the control units, check that the processor contains the required application. Failure to follow these instructions will result in death or serious injury. 35011052.06 07/2008 181 TSX P57/TSX H57 processors: diagnostics Changing the RAM memory backup battery on TSX P57 At a Glance This battery, which is in the TSX PSY … power supply module (see Supply modules: description, p. 344), ensures that the internal RAM memory of the processor and the real-time clock are saved in case of a voltage power outage. It is delivered in the same packaging as the power supply module and must be installed by the user. Installing the battery Carry out the following steps: Step Action 1 Open the access flap on the front of the power supply module. 2 Place the battery in its slot, taking care to respect polarities as marked on the module. 3 Close the access flap. Illustration 182 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Changing the battery The battery can be changed every year as a preventative measure or when the BAT LED is lit. To do this, use the same procedure as for installation, and carry out the following steps: Step Action 1 Open the access flap for the battery. 2 Remove the old battery from its slot. 3 Put the new battery into place. 4 Close and lock the access flap. Illustration If there is a power outage while the battery is being changed, the RAM memory is saved by the processor, as it has its own offline independent save function. Note: so as not to forget to change the battery, you are advised to record the date of the next change in the space provided on the inside of the flap. 35011052.06 07/2008 183 TSX P57/TSX H57 processors: diagnostics How often must the battery be changed? Period of battery backup The length of time during which the battery provides backup of the processor’s internal RAM memory and the real-time clock depends on two factors: the percentage of time for which the PLC is switched off and therefore the battery is being used, z the ambient temperature when the PLC is switched off. z Summary table: ≤ 30°C 40°C 50°C 60°C PLC off for 12 hours 5 years per day 3 years 2 years 1 year PLC off for 1 hour per day 5 years 4.5 years 4 years Ambient temperature when inoperative Backup time 5 years Independent saving by the processor The processors have their own offline independent save function to save the processor’s internal RAM memory and the real-time clock, which allows the removal of: z the battery, the power supply or the TSX P57 processor. The backup time depends on the ambient temperature. Assuming that the processor was switched on previously, the backup time varies in the following way: 184 Ambient temperature when switching off 20°C 30°C 40°C 50°C Backup time 2h 45mn 20mn 8mn 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Changing the Battery of a RAM Memory PCMCIA Card on the TSX P57 Introduction Some RAM memory PCMCIA cards (TSX MRP etc.) have a single battery (reference TSX BAT M01) which needs to be changed. The various memory card references are found in a summary table (see Correspondence Table, p. 175). How to change the battery Carry out the following steps: Step Action 1 Remove the card from its slot by pulling the clip forwards out of the PLC. 2 Separate the PCMCIA card from its clip by pulling the two components (card and clip) in opposite directions. 3 Hold the PCMCIA card so you can access the battery slot. This is at the end of the card without the connector. 4 Unlock the battery holder, which is at the end of the card without the connector. To do this, press the lock towards the bottom of the card (the opposite direction to the write protection micro-switch) while pulling towards the back (see illustration). 5 Remove the battery and holder unit from its slot (see illustration). 6 Swap the old battery for an identical 3V battery. Polarities must be observed by placing the + labels on the holder and the battery on the same side. 7 Place the battery and holder unit back in its slot, then lock it. To do this, carry out the removal procedure in reverse. 8 Fix the PCMCIA card into its clip. 9 Put the card with its clip back into the PLC. Illustration Write protection Lock Battery slot 6 Labels 35011052.06 07/2008 185 TSX P57/TSX H57 processors: diagnostics Battery life See the following table: PCMCIA card stored in normal conditions (-20°C to 70°C) 12 months PCMCIA card fitted in an operating PLC (0°C to 60°C) 36 months Note: During operation, the processor’s ERR LED flashes if the PCMCIA card battery needs replacing. 186 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Changing the Battery of a TSX MRP DS 2048 P RAM Memory Card Introduction The TSX MRP DS 2048 P memory extension card must have a battery (product ref. TSX BAT M01) in order to help ensure data is saved. How to Change the Battery Carry out the following steps: 35011052.06 07/2008 Step Action 1 Remove the card from its slot by pulling the clip forwards out of the PLC. 2 Open the PCMCIA card clip. 3 Hold the PCMCIA card so you can access the battery slot. This is at the end of the card without the connector. 4 Unlock the battery flap located at the edge of the card. To do this press the lock towards the top of the card (the opposite direction to the write protection microswitch. 187 TSX P57/TSX H57 processors: diagnostics Step 5 Action Take off the battery flap. To do this, slightly rotate the socket as shown in the diagram. Take the card out of its slot. Battery slot Lock Write protection Labels 6 Swap the old battery for an identical 3V battery. It is essential to respect the polarities as detailed on the memory card label. 7 Replace and then lock the battery hatch. To do this, carry out the removal procedure in reverse. 8 Close the PCMCIA card clip. 9 Put the card with its clip back into the PLC. Note: For the new card reference TSX MRP F 004M, (replacing card TSX MRP DS 2048 P), z with PV lower than or equal to 03, see (Installation Manual Volume 1), z with PV greater than or equal to 03, see Changing the Batteries of a PCMCIA Memory Card, p. 189, Battery Life 188 See the following table: PCMCIA card stored in normal conditions. 12 months PCMCIA card fitted in an operating PLC (0°C to 60°C) 36 months 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Changing the Batteries of a PCMCIA Memory Card General Points Memory cards: TSX MRP P• standard RAM TSX MRP C• RAM for files and application and TSX MCP C• Flash EPROM z TSX MRP F• data and file-type z z have 2 backup batteries TSX BAT M02 (main) and TSX BAT M03 (auxiliary) that need to be changed. Two methods exist: A preventive method of periodic battery changing that does not involve checking the condition of the batteries, z A predictive method, based on the signal sent by a system bit. This method is only available in certain memory cards. z Preventive Method This method is valid for all memory card versions and for all the PLCs using these cards (i.e. Premium, Atrium). Change both batteries following the indications related to the PCMCIA PV, how the PLC is used and the battery life (see Battery Lifetimes for the PCMCIA Memory Card, p. 193). The two batteries may be changed in any order: the application will be saved by the memory card. Battery changing procedure: see the instructions provided with the memory cards. Note: z Batteries should not be removed from their positions simultaneously. One battery backs up the data and applications, while the other is being replaced. z The memory card should never remain more than 24 hours without a main battery in working state. z To economize, auxiliary batteries may only be changed every 1.5 years which is the standard battery life. z The battery lives shown above are calculated at ambient operating temperature around 60°C, and PLC only powered up 21% of total annual time (i.e. 8 hours a day, with 30 days maintenance per year). 35011052.06 07/2008 189 TSX P57/TSX H57 processors: diagnostics Predictive method This maintenance method uses the %S67 and %S75 bits and the ERR diode on the Premium interface. This method implies that the auxiliary battery is changed every 18 months. It can only be implemented: on low or medium capacity PV06 RAM memory cards (see product version on the card label), having the following storage capacity when used with a PL7 ≤ 768K (TSX MRP P •••• K, TSX MCP C •••• K, TSX MRP C 448 K, TSX MRP C 768 K), z providing the card is installed in the top PCMCIA slot on all the Premium processors. z providing the card is installed in the bottom PCMCIA slot on Premium TSX P57 4•• and Premium TSX P57 5•• processors. z %S67 system bit (top slot card) or %S75 system bit (bottom slot card) on 1 or flashing processor interface ERR diode indicate main battery low. The main battery must be replaced within 8 days, as indicated in the instructions provided with the memory cards. Note: If the PLC is to remain switched off or the memory card is removed for more than 8 days, and the main battery has exceeded its standard life, save the application under PL7. Changing the Batteries 190 Perform the following steps: Step Action 1 Take the card out of its slot (see Mounting/Removing a PCMCIA Memory Extension Card on a TSX P57 Processor, p. 164). 2 Separate the PCMCIA card (see Mounting/Removing a PCMCIA Memory Extension Card on a TSX P57 Processor, p. 164) from its clip (or caddy). 3 Hold the PCMCIA card so you can access the battery slot. This is at the end of the card without the connector. 4 Replacement of the TSX BAT M02 battery: see table 1. Replacement of the TSX BAT M03 battery: see table 2. 5 Attach the PCMCIA card (see Mounting/Removing a PCMCIA Memory Extension Card on a TSX P57 Processor, p. 164) to its clip (or caddy). 6 Place the card back in the PLC. (see Mounting/Removing a PCMCIA Memory Extension Card on a TSX P57 Processor, p. 164) 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Procedure for the TSX BAT M02 Battery: 35011052.06 07/2008 The following table shows the procedure for changing the main battery: Step Action 1 Toggle the changeover lever toward the TSX BAT M03 (AUX) battery in order to remove the drawer of the main battery. 2 Remove the used battery from its holder: 3 Place the new battery in the holder, taking care to respect the polarity. 4 Insert the holder containing the battery in the card. Illustration 191 TSX P57/TSX H57 processors: diagnostics Procedure for the TSX BAT M03 Battery: 192 The following table shows the procedure for changing the auxiliary battery: Step Action 1 Toggle the changeover lever toward the TSX BAT M02 (MAIN) battery in order to remove the drawer of the battery. 2 Remove the used battery from its holder: 3 Place the new battery in the holder, taking care to respect the polarity. 4 Insert the holder containing the battery in the card. Illustration 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Battery Lifetimes for the PCMCIA Memory Card Purpose The purpose of this document is to give detailed information about the lifetime of batteries inside PCMCIA memory cards. The estimation of these lifetimes are based on data from component manufacturers. Scope The lifetime information is estimated for: RAM PCMCIA memory cards, The three different cases of Product Version (PV): PV1/2/3, PV4/5 and PV6, z Four ambient temperatures for the PLC location: 25°C / 40°C / 50°C / 60°C, z Four different usage cases of the PCMCIAs: 100%, 92%, 66% and 33% of PLC power-up time. These values are for the following customer configurations: z 100%: PLC powered up all year long or during 51 weeks, z 92%: PLC powered up all year long except during one month of maintenance, z 66%: PLC powered up all year long except during all weekends plus one month of maintenance, z 33%: PLC powered up all year long 12 hours a day, except during all weekends plus one month of maintenance. z A Min (minimum) and a Typical lifetime value: z The Min value comes from the most unfavorable characteristics given by the component manufacturers. The actual observed lifetime will be greater than this value. z The typical value comes from the typical characteristics of the component. z z 35011052.06 07/2008 193 TSX P57/TSX H57 processors: diagnostics Main Battery Lifetime of PV1/2/ 3 PCMCIA (in Years) The table below presents the lifetime of main battery TSX BAT M01(PV1/2/3) for PCMCIA memory cards: PV1/2/3 For a 25°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 7.10 7.10 6.71 5.58 5.77 3.36 4.82 2.20 TSX MCP C 512K 7.10 7.10 6.71 5.65 5.77 3.46 4.82 2.28 TSX MCP C 002M 7.10 7.10 6.29 3.82 4.66 1.57 3.45 0.88 TSX MRP P128K 7.10 7.10 6.71 5.58 5.77 3.36 4.82 2.20 TSX MRP P224K 7.10 7.10 6.71 5.65 5.77 3.46 4.82 2.28 TSX MRP P384K 7.10 7.10 6.71 4.99 5.77 2.60 4.82 1.59 TSX MRP C448K 7.10 7.10 6.29 4.65 4.66 2.24 3.45 1.33 TSX MRP C768K 7.10 7.10 6.29 4.65 4.66 2.24 3.45 1.33 TSX MRP C001M 7.10 7.10 5.91 3.95 3.91 1.66 2.68 0.94 TSX MRP C01M7 7.10 7.10 5.58 3.43 3.36 1.32 2.20 0.72 TSX MRP C002M 7.10 7.10 5.91 3.34 3.91 1.26 2.68 0.69 TSX MRP C003M 7.10 7.10 5.58 2.60 3.36 0.87 2.20 0.47 TSX MRP C007M 7.10 7.10 4.56 1.59 2.16 0.46 1.27 0.24 TSX MRP F004M 7.10 7.10 5.58 2.60 3.36 0.87 2.20 0.47 TSX MRP F008M 7.10 7.10 4.56 1.59 2.16 0.46 1.27 0.24 PV1/2/3 For a 40°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 3.55 3.55 3.54 3.20 3.54 2.46 3.48 1.87 TSX MCP C 512K 3.55 3.55 3.54 3.22 3.54 2.51 3.48 1.93 TSX MCP C 002M 3.55 3.55 3.42 2.53 3.08 1.34 2.71 0.82 TSX MRP P128K 3.55 3.55 3.54 3.20 3.54 2.46 3.48 1.87 TSX MRP P224K 3.55 3.55 3.54 3.22 3.54 2.51 3.48 1.93 TSX MRP P384K 3.55 3.55 3.54 3.00 3.54 2.02 3.48 1.41 TSX MRP C448K 3.55 3.55 3.42 2.87 3.08 1.80 2.71 1.20 TSX MRP C768K 3.55 3.55 3.42 2.87 3.08 1.80 2.71 1.20 TSX MRP C001M 3.55 3.55 3.30 2.59 2.74 1.40 2.21 0.87 194 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics PV1/2/3 For a 40°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MRP C01M7 3.55 3.55 3.20 2.35 2.46 1.15 1.87 0.69 TSX MRP C002M 3.55 3.55 3.30 2.31 2.74 1.11 2.21 0.65 TSX MRP C003M 3.55 3.55 3.20 1.93 2.46 0.80 1.87 0.45 TSX MRP C007M 3.55 3.55 2.84 1.31 1.75 0.44 1.16 0.24 TSX MRP F004M 3.55 3.55 3.20 1.93 2.46 0.80 1.87 0.45 TSX MRP F008M 3.55 3.55 2.84 1.31 1.75 0.44 1.16 0.24 PV1/2/3 For a 50°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 2.35 2.35 2.42 2.25 2.69 2.02 3.10 1.75 TSX MCP C 512K 2.35 2.35 2.42 2.26 2.69 2.05 3.10 1.81 TSX MCP C 002M 2.35 2.35 2.36 1.90 2.42 1.20 2.47 0.80 TSX MRP P128K 2.35 2.35 2.42 2.25 2.69 2.02 3.10 1.75 TSX MRP P224K 2.35 2.35 2.42 2.26 2.69 2.05 3.10 1.81 TSX MRP P384K 2.35 2.35 2.42 2.15 2.69 1.71 3.10 1.34 TSX MRP C448K 2.35 2.35 2.36 2.09 2.42 1.55 2.47 1.15 TSX MRP C768K 2.35 2.35 2.36 2.09 2.42 1.55 2.47 1.15 TSX MRP C001M 2.35 2.35 2.31 1.93 2.20 1.25 2.05 0.85 TSX MRP C01M7 2.35 2.35 2.25 1.80 2.02 1.04 1.75 0.67 TSX MRP C002M 2.35 2.35 2.31 1.77 2.20 1.01 2.05 0.64 TSX MRP C003M 2.35 2.35 2.25 1.54 2.02 0.75 1.75 0.44 TSX MRP C007M 2.35 2.35 2.07 1.12 1.51 0.42 1.11 0.23 TSX MRP F004M 2.35 2.35 2.25 1.54 2.02 0.75 1.75 0.44 TSX MRP F008M 2.35 2.35 2.07 1.12 1.51 0.42 1.11 0.23 PV1/2/3 For a 60°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 1.57 1.57 1.63 1.56 1.91 1.54 2.40 1.50 TSX MCP C 512K 1.57 1.57 1.63 1.56 1.91 1.56 2.40 1.54 35011052.06 07/2008 195 TSX P57/TSX H57 processors: diagnostics PV1/2/3 For a 40°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MRP C01M7 3.55 3.55 3.20 2.35 2.46 1.15 1.87 0.69 TSX MRP C002M 3.55 3.55 3.30 2.31 2.74 1.11 2.21 0.65 TSX MRP C003M 3.55 3.55 3.20 1.93 2.46 0.80 1.87 0.45 TSX MRP C007M 3.55 3.55 2.84 1.31 1.75 0.44 1.16 0.24 TSX MRP F004M 3.55 3.55 3.20 1.93 2.46 0.80 1.87 0.45 TSX MRP F008M 3.55 3.55 2.84 1.31 1.75 0.44 1.16 0.24 PV1/2/3 For a 50°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 2.35 2.35 2.42 2.25 2.69 2.02 3.10 1.75 TSX MCP C 512K 2.35 2.35 2.42 2.26 2.69 2.05 3.10 1.81 TSX MCP C 002M 2.35 2.35 2.36 1.90 2.42 1.20 2.47 0.80 TSX MRP P128K 2.35 2.35 2.42 2.25 2.69 2.02 3.10 1.75 TSX MRP P224K 2.35 2.35 2.42 2.26 2.69 2.05 3.10 1.81 TSX MRP P384K 2.35 2.35 2.42 2.15 2.69 1.71 3.10 1.34 TSX MRP C448K 2.35 2.35 2.36 2.09 2.42 1.55 2.47 1.15 TSX MRP C768K 2.35 2.35 2.36 2.09 2.42 1.55 2.47 1.15 TSX MRP C001M 2.35 2.35 2.31 1.93 2.20 1.25 2.05 0.85 TSX MRP C01M7 2.35 2.35 2.25 1.80 2.02 1.04 1.75 0.67 TSX MRP C002M 2.35 2.35 2.31 1.77 2.20 1.01 2.05 0.64 TSX MRP C003M 2.35 2.35 2.25 1.54 2.02 0.75 1.75 0.44 TSX MRP C007M 2.35 2.35 2.07 1.12 1.51 0.42 1.11 0.23 TSX MRP F004M 2.35 2.35 2.25 1.54 2.02 0.75 1.75 0.44 TSX MRP F008M 2.35 2.35 2.07 1.12 1.51 0.42 1.11 0.23 PV1/2/3 For a 60°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 1.57 1.57 1.63 1.56 1.91 1.54 2.40 1.50 TSX MCP C 512K 1.57 1.57 1.63 1.56 1.91 1.56 2.40 1.54 196 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics PV1/2/3 For a 60°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 002M 1.57 1.57 1.61 1.38 1.77 1.01 2.00 0.74 TSX MRP P128K 1.57 1.57 1.63 1.56 1.91 1.54 2.40 1.50 TSX MRP P224K 1.57 1.57 1.63 1.56 1.91 1.56 2.40 1.54 TSX MRP P384K 1.57 1.57 1.63 1.51 1.91 1.36 2.40 1.19 TSX MRP C448K 1.57 1.57 1.61 1.47 1.77 1.25 2.00 1.04 TSX MRP C768K 1.57 1.57 1.61 1.47 1.77 1.25 2.00 1.04 TSX MRP C001M 1.57 1.57 1.58 1.40 1.65 1.05 1.72 0.78 TSX MRP C01M7 1.57 1.57 1.56 1.33 1.54 0.90 1.50 0.63 TSX MRP C002M 1.57 1.57 1.58 1.31 1.65 0.87 1.72 0.60 TSX MRP C003M 1.57 1.57 1.56 1.18 1.54 0.67 1.50 0.42 TSX MRP C007M 1.57 1.57 1.47 0.92 1.23 0.40 1.00 0.23 TSX MRP F004M 1.57 1.57 1.56 1.18 1.54 0.67 1.50 0.42 TSX MRP F008M 1.57 1.57 1.47 0.92 1.23 0.40 1.00 0.23 35011052.06 07/2008 197 TSX P57/TSX H57 processors: diagnostics Main Battery Lifetime of PV4/5 PCMCIA (in Years) The table below presents the lifetime of main battery TSX BAT M02 (PV4/5) for PCMCIA memory cards: PV4/5 For a 25°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 7.22 7.22 7.15 6.27 7.02 4.48 6.76 3.23 TSX MCP C 512K 7.22 7.22 7.15 6.33 7.02 4.59 6.76 3.35 TSX MCP C 002M 7.22 7.22 6.83 4.69 5.90 2.25 4.96 1.33 TSX MRP P128K 7.22 7.22 7.15 6.27 7.02 4.48 6.76 3.23 TSX MRP P224K 7.22 7.22 7.15 6.33 7.02 4.59 6.76 3.35 TSX MRP P384K 7.22 7.22 7.15 5.77 7.02 3.57 6.76 2.36 TSX MRP C448K 7.22 7.22 6.83 5.47 5.90 3.12 4.96 1.99 TSX MRP C768K 7.22 7.22 6.83 5.47 5.90 3.12 4.96 1.99 TSX MRP C001M 7.22 7.22 6.54 4.82 5.09 2.37 3.91 1.41 TSX MRP C01M7 7.22 7.22 6.27 4.30 4.48 1.91 3.23 1.10 TSX MRP C002M 7.22 7.22 6.54 4.20 5.09 1.83 3.91 1.04 TSX MRP C003M 7.22 7.22 6.27 3.41 4.48 1.29 3.23 0.71 TSX MRP C007M 7.22 7.22 5.39 2.21 3.02 0.70 1.91 0.37 TSX MRP F004M 7.22 7.22 6.27 3.41 4.48 1.29 3.23 0.71 TSX MRP F008M 7.22 7.22 5.39 2.21 3.02 0.70 1.91 0.37 PV4/5 For a 40°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 4.63 4.63 4.72 4.32 5.09 3.61 5.59 2.94 TSX MCP C 512K 4.63 4.63 4.72 4.35 5.09 3.68 5.59 3.04 TSX MCP C 002M 4.63 4.63 4.58 3.51 4.48 2.00 4.30 1.28 TSX MRP P128K 4.63 4.63 4.72 4.32 5.09 3.61 5.59 2.94 TSX MRP P224K 4.63 4.63 4.72 4.35 5.09 3.68 5.59 3.04 TSX MRP P384K 4.63 4.63 4.72 4.08 5.09 2.99 5.59 2.20 TSX MRP C448K 4.63 4.63 4.58 3.93 4.48 2.68 4.30 1.87 TSX MRP C768K 4.63 4.63 4.58 3.93 4.48 2.68 4.30 1.87 TSX MRP C001M 4.63 4.63 4.45 3.58 4.00 2.10 3.49 1.35 198 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics PV4/5 For a 40°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MRP C01M7 4.63 4.63 4.32 3.29 3.61 1.73 2.94 1.06 TSX MRP C002M 4.63 4.63 4.45 3.23 4.00 1.66 3.49 1.01 TSX MRP C003M 4.63 4.63 4.32 2.74 3.61 1.21 2.94 0.69 TSX MRP C007M 4.63 4.63 3.89 1.91 2.60 0.67 1.80 0.36 TSX MRP F004M 4.63 4.63 4.32 2.74 3.61 1.21 2.94 0.69 TSX MRP F008M 4.63 4.63 3.89 1.91 2.60 0.67 1.80 0.36 PV4/5 For a 50°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 2.58 2.58 2.69 2.56 3.12 2.50 3.89 2.39 TSX MCP C 512K 2.58 2.58 2.69 2.56 3.12 2.53 3.89 2.45 TSX MCP C 002M 2.58 2.58 2.64 2.25 2.88 1.61 3.22 1.16 TSX MRP P128K 2.58 2.58 2.69 2.56 3.12 2.50 3.89 2.39 TSX MRP P224K 2.58 2.58 2.69 2.56 3.12 2.53 3.89 2.45 TSX MRP P384K 2.58 2.58 2.69 2.47 3.12 2.18 3.89 1.88 TSX MRP C448K 2.58 2.58 2.64 2.41 2.88 2.01 3.22 1.63 TSX MRP C768K 2.58 2.58 2.64 2.41 2.88 2.01 3.22 1.63 TSX MRP C001M 2.58 2.58 2.60 2.28 2.68 1.67 2.74 1.23 TSX MRP C01M7 2.58 2.58 2.56 2.15 2.50 1.42 2.39 0.98 TSX MRP C002M 2.58 2.58 2.60 2.13 2.68 1.38 2.74 0.94 TSX MRP C003M 2.58 2.58 2.56 1.90 2.50 1.05 2.39 0.66 TSX MRP C007M 2.58 2.58 2.40 1.46 1.97 0.62 1.58 0.35 TSX MRP F004M 2.58 2.58 2.56 1.90 2.50 1.05 2.39 0.66 TSX MRP F008M 2.58 2.58 2.40 1.46 1.97 0.62 1.58 0.35 PV4/5 For a 60°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 1.75 1.75 1.84 1.78 2.21 1.88 2.95 2.00 TSX MCP C 512K 1.75 1.75 1.84 1.78 2.21 1.90 2.95 2.04 35011052.06 07/2008 199 TSX P57/TSX H57 processors: diagnostics PV4/5 For a 60°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 002M 1.75 1.75 1.82 1.62 2.09 1.33 2.55 1.06 TSX MRP P128K 1.75 1.75 1.84 1.78 2.21 1.88 2.95 2.00 TSX MRP P224K 1.75 1.75 1.84 1.78 2.21 1.90 2.95 2.04 TSX MRP P384K 1.75 1.75 1.84 1.73 2.21 1.70 2.95 1.63 TSX MRP C448K 1.75 1.75 1.82 1.71 2.09 1.59 2.55 1.44 TSX MRP C768K 1.75 1.75 1.82 1.71 2.09 1.59 2.55 1.44 TSX MRP C001M 1.75 1.75 1.80 1.64 1.98 1.37 2.24 1.11 TSX MRP C01M7 1.75 1.75 1.78 1.57 1.88 1.20 2.00 0.91 TSX MRP C002M 1.75 1.75 1.80 1.56 1.98 1.17 2.24 0.87 TSX MRP C003M 1.75 1.75 1.78 1.44 1.88 0.92 2.00 0.62 TSX MRP C007M 1.75 1.75 1.70 1.17 1.56 0.57 1.40 0.34 TSX MRP F004M 1.75 1.75 1.78 1.44 1.88 0.92 2.00 0.62 TSX MRP F008M 1.75 1.75 1.70 1.17 1.56 0.57 1.40 0.34 200 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Main Battery Lifetime of PV6 PCMCIA (in Years) The table below presents the lifetime of main battery TSX BAT M02 (PV6) for PCMCIA memory cards: PV6 For a 25°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 7.2 7.2 7.2 6.3 7.0 4.5 6.8 3.2 TSX MCP C 512K 7.2 7.2 7.2 6.5 7.0 5.1 6.8 3.9 TSX MCP C 002M 7.2 7.2 6.8 5.8 5.9 3.6 5.0 2.4 TSX MRP P128K 7.2 7.2 7.2 6.3 7.0 4.5 6.8 3.2 TSX MRP P224K 7.2 7.2 7.2 6.5 7.0 5.1 6.8 3.9 TSX MRP P384K 7.2 7.2 7.2 6.5 7.0 5.1 6.8 3.9 TSX MRP C448K 7.2 7.2 6.8 5.8 5.9 3.6 5.0 2.4 TSX MRP C768K 7.2 7.2 6.8 5.8 5.9 3.6 5.0 2.4 TSX MRP C001M 7.2 7.2 6.5 5.2 5.1 2.8 3.9 1.7 TSX MRP C01M7 7.2 7.2 6.3 4.7 4.5 2.3 3.2 1.4 TSX MRP C002M 7.2 7.2 6.5 5.2 5.1 2.8 3.9 1.7 TSX MRP C003M 7.2 7.2 6.3 4.7 4.5 2.3 3.2 1.4 TSX MRP C007M 7.2 7.2 5.4 3.5 3.0 1.3 1.9 0.7 TSX MRP F004M 7.2 7.2 6.3 4.7 4.5 2.3 3.2 1.4 TSX MRP F008M 7.2 7.2 5.4 3.5 3.0 1.3 1.9 0.7 PV6 For a 40°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 4.6 4.6 4.7 4.3 5.1 3.6 5.6 2.9 TSX MCP C 512K 4.6 4.6 4.7 4.4 5.1 4.0 5.6 3.5 TSX MCP C 002M 4.6 4.6 4.6 4.1 4.5 3.0 4.3 2.2 TSX MRP P128K 4.6 4.6 4.7 4.3 5.1 3.6 5.6 2.9 TSX MRP P224K 4.6 4.6 4.7 4.4 5.1 4.0 5.6 3.5 TSX MRP P384K 4.6 4.6 4.7 4.4 5.1 4.0 5.6 3.5 TSX MRP C448K 4.6 4.6 4.6 4.1 4.5 3.0 4.3 2.2 TSX MRP C768K 4.6 4.6 4.6 4.1 4.5 3.0 4.3 2.2 TSX MRP C001M 4.6 4.6 4.4 3.8 4.0 2.4 3.5 1.6 35011052.06 07/2008 201 TSX P57/TSX H57 processors: diagnostics PV6 For a 40°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MRP C01M7 4.6 4.6 4.3 3.5 3.6 2.0 2.9 1.3 TSX MRP C002M 4.6 4.6 4.4 3.8 4.0 2.4 3.5 1.6 TSX MRP C003M 4.6 4.6 4.3 3.5 3.6 2.0 2.9 1.3 TSX MRP C007M 4.6 4.6 3.9 2.8 2.6 1.2 1.8 0.7 TSX MRP F004M 4.6 4.6 4.3 3.5 3.6 2.0 2.9 1.3 TSX MRP F008M 4.6 4.6 3.9 2.8 2.6 1.2 1.8 0.7 PV6 For a 50°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 2.6 2.6 2.7 2.6 3.1 2.5 3.9 2.4 TSX MCP C 512K 2.6 2.6 2.7 2.6 3.1 2.7 3.9 2.7 TSX MCP C 002M 2.6 2.6 2.6 2.5 2.9 2.2 3.2 1.9 TSX MRP P128K 2.6 2.6 2.7 2.6 3.1 2.5 3.9 2.4 TSX MRP P224K 2.6 2.6 2.7 2.6 3.1 2.7 3.9 2.7 TSX MRP P384K 2.6 2.6 2.7 2.6 3.1 2.7 3.9 2.7 TSX MRP C448K 2.6 2.6 2.6 2.5 2.9 2.2 3.2 1.9 TSX MRP C768K 2.6 2.6 2.6 2.5 2.9 2.2 3.2 1.9 TSX MRP C001M 2.6 2.6 2.6 2.4 2.7 1.9 2.7 1.5 TSX MRP C01M7 2.6 2.6 2.6 2.3 2.5 1.6 2.4 1.2 TSX MRP C002M 2.6 2.6 2.6 2.4 2.7 1.9 2.7 1.5 TSX MRP C003M 2.6 2.6 2.6 2.3 2.5 1.6 2.4 1.2 TSX MRP C007M 2.6 2.6 2.4 1.9 2.0 1.1 1.6 0.7 TSX MRP F004M 2.6 2.6 2.6 2.3 2.5 1.6 2.4 1.2 TSX MRP F008M 2.6 2.6 2.4 1.9 2.0 1.1 1.6 0.7 PV6 For a 60°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 224K 1.8 1.8 1.8 1.8 2.2 1.9 3.0 2.0 TSX MCP C 512K 1.8 1.8 1.8 1.8 2.2 2.0 3.0 2.2 202 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics PV6 For a 60°C PLC ambient temperature 100% powered up 92% PU (30d maint. 66% PU (WE. 30d maint. 33% PU (12h.WE. 30d maint. Typical Min Typical Min Typical Min Typical Min TSX MCP C 002M 1.8 1.8 1.8 1.7 2.1 1.7 2.5 1.6 TSX MRP P128K 1.8 1.8 1.8 1.8 2.2 1.9 3.0 2.0 TSX MRP P224K 1.8 1.8 1.8 1.8 2.2 2.0 3.0 2.2 TSX MRP P384K 1.8 1.8 1.8 1.8 2.2 2.0 3.0 2.2 TSX MRP C448K 1.8 1.8 1.8 1.7 2.1 1.7 2.5 1.6 TSX MRP C768K 1.8 1.8 1.8 1.7 2.1 1.7 2.5 1.6 TSX MRP C001M 1.8 1.8 1.8 1.7 2.0 1.5 2.2 1.3 TSX MRP C01M7 1.8 1.8 1.8 1.6 1.9 1.3 2.0 1.1 TSX MRP C002M 1.8 1.8 1.8 1.7 2.0 1.5 2.2 1.3 TSX MRP C003M 1.8 1.8 1.8 1.6 1.9 1.3 2.0 1.1 TSX MRP C007M 1.8 1.8 1.7 1.4 1.6 0.9 1.4 0.6 TSX MRP F004M 1.8 1.8 1.8 1.6 1.9 1.3 2.0 1.1 TSX MRP F008M 1.8 1.8 1.7 1.4 1.6 0.9 1.4 0.6 Minimum Lifetime of the Main Battery, in a Powered Down PLC In a powered down PLC, the minimum lifetime of the main battery is 6 months in PV6 PCMCIAs. Auxiliary Battery Lifetime The auxiliary battery TSX BATM 03 is included in the PCMCIA product. Whatever the usage cases and ambient temperature, the lifetime of the auxiliary battery is: 5 years in PV1/2/3 1.7 years in PV4/5 z 5 years in PV6 z z 35011052.06 07/2008 203 TSX P57/TSX H57 processors: diagnostics What happens after you press the processor RESET button General All processors have a RESET button on their front panel, which when pressed, causes a cold start of the PLC, in RUN or in STOP mode (starting in RUN or in STOP mode is defined at configuration), on the application contained in the memory card (or in the internal RAM)… RESET following a fault detected by the processor As soon as a processor detects a fault, the alarm relay on rack 0 (with TSX 57 processor) is deactivated (open contact) and the module outputs switch to fallback position or are maintained in the current state depending on the selection made in configuration. Pressing the RESET button causes the PLC, forced into STOP, to cold start. Note: When the RESET button is pressed, and during the PLC cold start, the terminal link is deactivated. 204 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Finding errors using processor state LEDs General The state LEDs situated on the processor enable the user to be informed about the operating mode of the PLC but on possible errors. Errors detected by the PLC concerned: circuits constituting the PLC and/or its modules: internal errors, the process controlled by the PLC or the cabling of the process: external errors, z functioning of the application executed by the PLC: internal or external errors. z z Error detection Detecting errors is carried out during start-up (autotest) or during functioning (this is the case for most hardware errors), during exchanges with modules or during the execution of a program instruction. Certain "serious" errors require the PLC to be restarted, others are controlled by the user who decides on the behavior to adopt according to the desired level of application function. There are three types of error: non blocking, blocking, z processor or system error. z z 35011052.06 07/2008 205 TSX P57/TSX H57 processors: diagnostics Non blocking errors General This concerns an anomaly, provoked by an input/output error on the bus X, on the FIPIO bus or by the execution of an instruction. It can be processed by the user program and does not change the PLC state. Non blocking errors linked to inputs/outputs The identification of a non blocking error linked to the inputs/outputs is signaled by: the I/O state LED of the processor is lit, the I/O state LEDs of the modules responding to a fault are lit, (on bus X and FIPIO bus), z the bits and error words associated to the channel: z Inputs/Outputs on bus X: %Ixy.i.ERR bit = 1 indicates a detected channel fault (implicit exchanges), %Mwxy.i.2 words indicate the type of channel error (explicit exchanges), z Inputs/Outputs on FIPIO bus: %I\p.2.c\m.v.ERR bit = 1 indicates a detected channel fault (implicit exchanges), %MW\p.2.c\m.v.2 words indicate the type of channel errors (explicit exchanges), z bits and error words associated with the module: z Module on bus X: %Ixy.MOD.ERR bit = 1 indicates a detected channel fault (implicit exchanges), %MWxy.MOD.2 words indicate the type of channel error (explicit exchanges), z Module on FIPIO bus: %I\p.2.c\0.MOD.ERR bit = 1 indicates a detected channel fault (implicit exchanges), %MW\p.2.c\0.MOD.2 words indicate the type of channel error (explicit exchanges), z system bits: %S10: I/O error (on bus X or FIPIO bus), %S16: I/O error (on bus X and FIPIO bus) in the task in progress, %S40 à %S47: I/O error in racks at addresses 0 to 7 on the bus X. z z Diagnostics table: Status LED 206 ERR I/O System bits Errors RUN i i To %S10 Input/output error: channel supply fault, channel disjointed, module not conforming to configuration, out of service, module supply fault. i i To %S16 Error on input/output in a task. 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics i i To %S40 to %S47 Error on inputs/outputs at rack level (%S40: rack 0, %S47: rack 7) Legend: To: Lit LED, I: State not determined. Non blocking errors linked to program execution The indication of a non blocking error linked to program execution is signaled by setting to state 1 of one or several system bits %S15, %S18, %S20. The test and setting to state 0 of the system bits are controlled by the user. Diagnostics table: Status LED RUN ERR System bits Errors I/O To i i %S15=1 Character string manipulation error. To i i %S18=1 Capacity overrun, error on floating point or division by 0. To i i %S20=1 Index overflow. Legend: To: Lit LED, I: State not determined. Note: The program diagnostics function, accessible through the PL7 Pro software, enables certain non blocking errors linked to the program execution, to be turned into blocking errors. The nature of the error is indicated in the system word %SW 125. 35011052.06 07/2008 207 TSX P57/TSX H57 processors: diagnostics Blocking errors General These errors, provoked by the application program, disable its execution but do not cause system errors. On such an error, the application stops immediately and goes to HALT state (the tasks are all stopped in their current instruction). There are two possibilities for restarting the application: z z by the command INIT through the PL7 Junior or PL7 Pro software, by the processor RESET button. The application is thus in a preliminary state: the data has its preliminary values, the tasks are stopped at the end of the cycle, the input image is updated and the outputs are commissioned in fallback position, the RUN command enables application restart. The indication of a blocking error is signaled by the state LEDs (ERR and RUN) flashing and according to the nature of the error by the setting to 1 of one or several of the system bits %S11 and %S26. The nature of the error is indicated in the system word %SW 125. Diagnostics table: State LEDs System Bits Errors RUN ERR I/O C C i %S11=1 Watchdog overrun C C i %S26=1 Overrun of the grafcet activity table Step, Grafcet not resolved C C i Executing the HALT instruction C C i Executing a non resolved JUMP Legend: C: blinking i: not determined 208 35011052.06 07/2008 TSX P57/TSX H57 processors: diagnostics Processor or system errors General These serious faults on either processor (hardware or software), or on bus X cabling no longer allow that the system will function correctly. They cause the PLC to restart in ERROR which requires a cold restart. The next cold restart will be forced into STOP to avoid the PLC falling back into error. Diagnostics table: State LEDs ERR I/O System word %SW124 Errors RUN E To To H’80’ System watchdog error or error on bus X cabling E C C H’81’ E To To Cabling error on bus X System code error, unforeseen error Overrun of the system task batteries Overrun of the PL7 task batteries Legend: To: on C: blinking E: not determined Diagnostics of processor errors: 35011052.06 07/2008 When the PLC has stopped in error, it is no longer able to communicate with a diagnostics device. The information relating to the errors is only accessible after a cold restart (see system word %SW124). In general, the information is not used by the user, only the information H’80’ and H’81’ can be used to diagnose a cabling error on the bus X. 209 TSX P57/TSX H57 processors: diagnostics 210 35011052.06 07/2008 TSX P57 103 processor 14 General characteristics of TSX P 57 103 processors TSX P 57 103 processors 35011052.06 07/2008 The following table gives the general characteristics of the TSX P 57 103 processor. Reference TSX P 57 103 Maximum configuration Maximum number of TSX RKY 12EX racks 2 Maximum number of TSX RKY 4EX/6EX/8EX racks 4 Maximum number with TSXRKY 12EX of slots with TSXRKY 4EX, 6EX, 8EX 21 27 211 TSX P57 103 processor Reference TSX P 57 103 Functions I/O profile (1) fixed Maximum number In-rack discrete I/O of channels In-rack analog I/O 512 Applications (counting, axis, etc.) 24 8 Maximum number Built-in UNI-TELWAY (terminal 1 of connections port, Ethernet) Network (ETHWAY, FIPWAY, Modbus Plus) 1 Master FIPIO (built-in) - Third party field bus - AS-i field bus Savable real-time clock Memory capacity Application structure 2 yes Processor internal RAM 32K16 PCMCIA memory Application area card (maximum Symbol Zone capacity) File area 64K16 Master task 1 Fast task 1 128K16 Event processing (of which 1 has priority) 32 Application code execution time for a 1K instruction Internal RAM 100% Boolean 0.66 ms 65% Boolean + 35% digital 0.95 ms PCMCIA card 100% Boolean 0.85 ms 65% Boolean + 35% digital 1.18 ms System overhead MAST task 1.5 ms FAST task 0.8 ms fixed I/O profile (1): the number of discrete I/Os, and application-specific and analog channels can be accumulated 212 35011052.06 07/2008 TSX P57 153 processor 15 General characteristics of TSX P57 153 processors TSX P 57 153 processors The following table gives the general characteristics of the TSX P 57 153 processor. Reference TSX P 57 153 Maximum configuration Maximum number of TSX RKY 12EX racks Maximum number of slots Functions with TSXRKY 12EX 21 with TSXRKY 4EX, 6EX, 8EX 27 Maximum number of channels In-rack discrete I/O 512 In-rack analog I/O 24 Maximum number of connections Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, Ethernet) 1 Master FIPIO (built-in) 63 Third party field bus - AS-i field bus 2 I/O profile (1) fixed Applications (counting, axis, etc.) 8 Savable real-time clock 35011052.06 07/2008 2 Maximum number of TSX RKY 4EX/6EX/8EX racks 4 yes 213 TSX P57 153 processor Reference TSX P 57 153 Memory capacity Processor internal RAM 32K16 PCMCIA memory card (maximum capacity) Application area 64K16 Symbol Zone - File area 128K16 Application structure Application code execution time for a 1K instruction System overhead Master task 1 Fast task 1 Event processing (1 has priority) 32 Internal RAM PCMCIA card MAST task FAST task 100% Boolean 0.66 ms 65% Boolean + 35% digital 0.95 ms 100% Boolean 0.85 ms 65% Boolean + 35% digital 1.18 ms without using the FIPIO bus 1.5 ms using the FIPIO bus 3.1 ms 0.8 ms fixed I/O profile (1): the number of discrete I/Os, and application-specific and analog channels can be accumulated 214 35011052.06 07/2008 TSX P57 203 processor 16 General characteristics of TSX P57 203 processors TSX P 57 203 processors The following table gives the general characteristics of the TSX P 57 203 processor. Reference TSX P 57 203 Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of slots 86 Functions with TSXRKY 4EX, 6EX, 8EX I/O profile (1) Maximum number of channels Maximum number of connections Savable real-time clock 35011052.06 07/2008 with TSXRKY 12EX 110 fixed In-rack discrete I/O 1024 In-rack analog I/O 80 Applications (counting, axis, etc.) 24 Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, Ethernet) 1 Master FIPIO (built-in) - Third party field bus 1 AS-i field bus 4 yes 215 TSX P57 203 processor Reference TSX P 57 203 Memory capacity Processor internal RAM 48K16 PCMCIA memory card (maximum capacity) Application area 160K16 Symbol Zone 256K16 File area 640K16 channel 0+ 2048K16 channel 1 Application structure Master task 1 Fast task 1 Event processing (of which 1 has priority) Application Internal RAM code execution time for a 1K PCMCIA card instruction System overhead 100% Boolean 64 0.21 ms 65% Boolean + 35% digital 0.28 ms 100% Boolean 0.27 ms 65% Boolean + 35% digital 0.40 ms MAST task 1 ms FAST task 0.35 ms fixed I/O profile (1): the number of discrete I/Os, and application-specific and analog channels can be accumulated 216 35011052.06 07/2008 TSX P57 253 processor 17 General characteristics of TSX P57 253 processors TSX P57 253 processor The following table gives the general characteristics of the TSX P 57 253 processor. Reference TSX P57 253 Maximum Maximum number of TSX RKY 12EX racks configuration Maximum number of TSX RKY 4EX/6EX/8EX racks Maximum number of slots Functions with TSXRKY 12EX with TSXRKY 4EX, 6EX, 8EX I/O profile (1) Maximum number of channels 8 16 86 110 fixed In-rack discrete I/O 1024 In-rack analog I/O 80 Applications (counting, axis, etc.) 24 Maximum number of connections Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, Ethernet) 1 Master FIPIO (built-in) 127 Third party field bus 1 AS-i field bus Savable real-time clock 35011052.06 07/2008 4 yes 217 TSX P57 253 processor Reference TSX P57 253 Memory capacity Processor internal RAM 64K16 PCMCIA memory card Application area (maximum capacity) Symbol Zone 160K16 File area Application structure 256K16 640K16 channel 0+ 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Application code execution time for a 1K instruction Internal RAM 100% Boolean 0.21 ms 65% Boolean + 35% digital 0.28 ms PCMCIA card 100% Boolean 0.27 ms 65% Boolean + 35% digital 0.40 ms System overhead MAST task without using the FIPIO bus 1 ms using the FIPIO bus 1.2 ms FAST task 0.35 ms fixed I/O profile (1): the number of discrete I/Os, and application-specific and analog channels can be accumulated 218 35011052.06 07/2008 TSX P57 2623 processor 18 TSX P57 2623 Processors: General Characteristics TSX P 57 2623 Processors The following table gives the general characteristics of the TSX P 57 2623 processor. Reference TSX P 57 2623 Maximum configuration Maximum number of TSX RKY 12EX racks Maximum number of slots 35011052.06 07/2008 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 with TSXRKY 12EX 86 with TSXRKY 4EX, 6EX, 8EX 110 219 TSX P57 2623 processor Reference TSX P 57 2623 Functions I/O profile (1) Maximum number of channels Maximum number of connections fixed In-rack discrete I/O 1024 In-rack analog I/O 80 Applications (counting, axis, etc.) 24 Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, 1 Modbus Plus, embedded Ethernet (2)) Master FIPIO (built-in) - Third party field bus 1 AS-i field bus Memory capacity Application structure Application code execution time for a 1K instruction yes Processor internal RAM 48K16 PCMCIA memory card (maximum capacity) Application area 160K16 Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Internal RAM 100% Boolean 0.21 ms 65% Boolean + 35% digital 0.28 ms PCMCIA card System overhead MAST task FAST task 220 4 Savable real-time clock 100% Boolean 0.27 ms 65% Boolean + 35% digital 0.40 ms 1 ms 0.35 ms 35011052.06 07/2008 TSX P57 2623 processor (1) Fixed I/O profile: the number of discrete I/Os, and application-specific and analog channels can be accumulated. (2) One of which is occupied by the TSX ETY PORT of the CPU. 35011052.06 07/2008 221 TSX P57 2623 processor 222 35011052.06 07/2008 TSX P57 2823 processor 19 TSX P57 2823 Processors: General Characteristics TSX P57 2823 Processor 35011052.06 07/2008 The following table gives the general characteristics of the TSX P 57 2823 processor. Reference TSX P57 2823 Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of with TSXRKY 12EX slots with TSXRKY 4EX, 6EX, 8EX 86 110 223 TSX P57 2823 processor Reference TSX P57 2823 Functions I/O profile (1) fixed Maximum number of In-rack discrete I/O channels In-rack analog I/O 1024 Applications (counting, axis, etc.) Maximum number of Built-in UNI-TELWAY (terminal connections port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, embedded Ethernet (2)) 1 Master FIPIO (built-in) 127 Third party field bus 1 AS-i field bus 4 Savable real-time clock Memory capacity Application structure yes Processor internal RAM 64K16 PCMCIA memory card (maximum capacity) 160K16 Application area Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Application Internal RAM code execution time for a 1K PCMCIA card instruction 224 80 24 100% Boolean 0.21 ms 65% Boolean + 35% digital 0.28 ms 100% Boolean 0.27 ms 65% Boolean + 35% digital 0.40 ms 35011052.06 07/2008 TSX P57 2823 processor Reference TSX P57 2823 System overhead MAST task without using the FIPIO bus 1 ms using the FIPIO bus 1.2 ms FAST task 0.35 ms (1) Fixed I/O profile: the number of discrete I/Os, and application-specific and analog channels can be accumulated (2) One of which is occupied by the TSX ETY PORT of the CPU. 35011052.06 07/2008 225 TSX P57 2823 processor 226 35011052.06 07/2008 TSX P57 303 processor 20 General characteristics of TSX P57 303 processors TSX P57 303 processor The following table gives the general characteristics of the TSX P 57 303 processor. Reference TSX P57 303 Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of with TSXRKY 12EX slots with TSXRKY 4EX, 6EX, 8EX 110 I/O profile (2) fixed Maximum number of In-rack discrete I/O channels In-rack analog I/O 1024 Functions Applications (counting, axis, etc.) 128 32 Maximum number of Built-in UNI-TELWAY (terminal connections port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, Ethernet) 3 Master FIPIO (built-in) - Third party field bus 2 AS-i field bus 8 Savable real-time clock 35011052.06 07/2008 86 yes 227 TSX P57 303 processor Reference TSX P57 303 Memory capacity Processor internal RAM 64K16/80K16(1) PCMCIA memory card (maximum capacity) Application area 384K16 Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Application structure Master task 1 Fast task 1 Event processing (of which 1 has priority) Application Internal RAM code execution time for a 1K PCMCIA card instruction System overhead 100% Boolean 64 0.15 ms 65% Boolean + 35% digital 0.21 ms 100% Boolean 0.22 ms 65% Boolean + 35% digital 0.32 ms MAST task 1 ms FAST task 0.25 ms (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. fixed I/O profile (2): the number of discrete I/Os, and application-specific and analog channels can be accumulated. 228 35011052.06 07/2008 TSX P57 303A processor 21 General characteristics of TSX P57 303A processors TSX P57 303A processor 35011052.06 07/2008 The following table gives the general characteristics of the TSX P 57 303A processor. Reference TSX P57 303A Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of with TSXRKY 12EX slots with TSXRKY 4EX, 6EX, 8EX 110 86 229 TSX P57 303A processor Reference TSX P57 303A Functions I/O profile (2) fixed Maximum number of In-rack discrete I/O channels In-rack analog I/O 128 Applications (counting, axis, etc.) Memory capacity Application structure 1 Network (ETHWAY, FIPWAY, Modbus Plus, Ethernet) 3 Master FIPIO (built-in) - Third party field bus 2 AS-i field bus 8 Savable real-time clock yes Processor internal RAM 64K16/80K16(1) PCMCIA memory card (maximum capacity) Application area 384K16 Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 100% Boolean 64 0.15 ms 65% Boolean + 35% digital 0.21 ms 100% Boolean 0.22 ms 65% Boolean + 35% digital 230 32 Maximum number of Built-in UNI-TELWAY (terminal connections port) Application Internal RAM code execution time for a 1K PCMCIA card instruction System overhead 1024 0.32 ms MAST task 1.15 ms FAST task 0.29 ms 35011052.06 07/2008 TSX P57 303A processor (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. fixed I/O profile (2): the number of discrete I/Os, and application-specific and analog channels can be accumulated. 35011052.06 07/2008 231 TSX P57 303A processor 232 35011052.06 07/2008 TSX P57 353 processor 22 General characteristics of TSX P57 353 processors TSX P57 353 processor The following table gives the general characteristics of the TSX P 57 353 processor. Reference TSX P57 353 Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of slots with TSXRKY 12EX 86 with TSXRKY 4EX, 6EX, 8EX 110 Functions I/O profile (2) Maximum number of channels Maximum number of connections fixed In-rack discrete I/O 1024 In-rack analog I/O 128 Applications (counting, axis, etc.) 32 Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, Ethernet) 3 Master FIPIO (built-in) 127 Third party field bus 2 AS-i field bus Savable real-time clock 35011052.06 07/2008 8 yes 233 TSX P57 353 processor Reference TSX P57 353 Memory capacity Processor internal RAM 80K16/96K16(1) PCMCIA memory card (maximum capacity) Application area 384K16 Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Application structure Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Application code execution time for a 1K instruction Internal RAM 100% Boolean 0.15ms 65% Boolean + 35% digital 0.21ms 100% Boolean 0.22ms 65% Boolean + 35% digital 0.32ms System overhead MAST task without using the FIPIO bus 1 ms using the FIPIO bus 1 ms PCMCIA card FAST task 0.25 ms (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. fixed I/O profile (2): the number of discrete I/Os, and application-specific and analog channels can be accumulated. 234 35011052.06 07/2008 TSX P57 353A processor 23 General characteristics of TSX P57 353A processors TSX P57 353A processor 35011052.06 07/2008 The following table gives the general characteristics of the TSX P 57 353A processor. Reference TSX P57 353A Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of slots with TSXRKY 12EX 86 with TSXRKY 4EX, 6EX, 8EX 110 235 TSX P57 353A processor Reference TSX P57 353A Functions I/O profile (2) Maximum number of channels Maximum number of connections Memory capacity Application structure 1024 In-rack analog I/O 128 Applications (counting, axis, etc.) 32 Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, Ethernet) 3 Master FIPIO (built-in) 127 Third party field bus 2 AS-i field bus 8 Savable real-time clock yes Processor internal RAM 80K16/96K16(1) PCMCIA memory card (maximum capacity) Application area 384K16 Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Application code execution time for a 1K instruction Internal RAM 100% Boolean 0.15ms 65% Boolean + 35% digital 0.21ms PCMCIA card 100% Boolean 0.22ms 65% Boolean + 35% digital 0.32ms System overhead MAST task without using the FIPIO bus 1.15 ms using the FIPIO bus 1.15 ms FAST task 236 fixed In-rack discrete I/O 0.29 ms 35011052.06 07/2008 TSX P57 353A processor (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. fixed I/O profile (2): the number of discrete I/Os, and application-specific and analog channels can be accumulated. 35011052.06 07/2008 237 TSX P57 353A processor 238 35011052.06 07/2008 TSX P57 353LA Processor 24 General Characteristics of TSX P57 353LA Processors TSX P57 353LA Processor 35011052.06 07/2008 The following table gives the general characteristics of the TSX P 57 353LA processor. Reference TSX P57 353LA Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of slots with TSXRKY 12EX 86 with TSXRKY 4EX, 6EX, 8EX 110 239 TSX P57 353LA Processor Reference TSX P57 353LA Functions I/O profile (2) Maximum number of channels Maximum number of connections Memory capacity Application structure In-rack discrete I/O 1024 In-rack analog I/O 128 Applications (counting, axis, etc.) 32 Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, Ethernet) 3 Master FIPIO (built-in) 127 Third party field bus 2 AS-i field bus 8 Savable real-time clock yes Processor internal RAM 80K16/96K16(1) PCMCIA memory card (maximum capacity) Application area 384K16 Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Application code execution time for a 1K instruction Internal RAM 100% Boolean 0.21 ms 65% Boolean + 35% digital 0.28 ms PCMCIA card 100% Boolean 0.27 ms 65% Boolean + 35% digital 0.40 ms System overhead MAST task FAST task 240 fixed without using the FIPIO bus 1 ms using the FIPIO bus 1.2 ms 0.35 ms 35011052.06 07/2008 TSX P57 353LA Processor (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. fixed I/O profile (2): the number of discrete I/Os, and application-specific and analog channels can be accumulated. 35011052.06 07/2008 241 TSX P57 353LA Processor 242 35011052.06 07/2008 TSX P57 3623 processor 25 TSX P57 3623 Processors: General Characteristics TSX P57 3623 Processor The following table gives the general characteristics of the TSX P 57 3623 processor. Reference TSX P57 3623 Maximum Maximum number of TSX RKY 12EX racks configuration Maximum number of TSX RKY 4EX/6EX/8EX racks Maximum number of with TSXRKY 12EX slots with TSXRKY 4EX, 6EX, 8EX 35011052.06 07/2008 8 16 86 110 243 TSX P57 3623 processor Reference TSX P57 3623 Functions I/O profile (2) fixed Maximum number of In-rack discrete I/O channels In-rack analog I/O 1024 128 Applications (counting, axis, etc.) 32 Memory capacity Application structure 244 Maximum number of Built-in UNI-TELWAY (terminal connections port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, embedded Ethernet (3)) 3 Master FIPIO (built-in) - Third party field bus 2 AS-i field bus 8 Savable real-time clock yes Processor internal RAM 80K16/96K16(1) PCMCIA memory card (maximum capacity) Application area 384K16 Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Application code execution time for a 1K instruction Internal RAM 100% Boolean 0.15 ms 65% Boolean + 35% digital 0.21 ms PCMCIA card 100% Boolean 0.22 ms 65% Boolean + 35% digital 0.32 ms System overhead MAST task 1 ms FAST task 0.25 ms 35011052.06 07/2008 TSX P57 3623 processor (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. (2) Fixed I/O profile: the number of discrete I/Os, and application-specific and analog channels can be accumulated. (3) One of which is occupied by the TSX ETY PORT of the CPU. 35011052.06 07/2008 245 TSX P57 3623 processor 246 35011052.06 07/2008 TSX P57 3623A processor 26 TSX P57 3623A Processors: General Characteristics TSX P57 3623A Processor The following table gives the general characteristics of the TSX P 57 3623A processor. Reference TSX P57 3623A Maximum Maximum number of TSX RKY 12EX racks configuration Maximum number of TSX RKY 4EX/6EX/8EX racks Maximum number of with TSXRKY 12EX slots with TSXRKY 4EX, 6EX, 8EX 35011052.06 07/2008 8 16 86 110 247 TSX P57 3623A processor Reference TSX P57 3623A Functions I/O profile (2) fixed Maximum number of In-rack discrete I/O channels In-rack analog I/O 1024 128 Applications (counting, axis, etc.) 32 Memory capacity Application structure 248 Maximum number of Built-in UNI-TELWAY (terminal connections port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, embedded Ethernet (3)) 3 Master FIPIO (built-in) - Third party field bus 2 AS-i field bus 8 Savable real-time clock yes Processor internal RAM 80K16/96K16(1) PCMCIA memory card (maximum capacity) Application area 384K16 Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Application code execution time for a 1K instruction Internal RAM 100% Boolean 0.15 ms 65% Boolean + 35% digital 0.21 ms PCMCIA card 100% Boolean 0.22 ms 65% Boolean + 35% digital 0.32 ms System overhead MAST task 1.15 ms FAST task 0.29 ms 35011052.06 07/2008 TSX P57 3623A processor (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. (2) Fixed I/O profile: the number of discrete I/Os, and application-specific and analog channels can be accumulated. (3) One of which is occupied by the TSX ETY PORT of the CPU. 35011052.06 07/2008 249 TSX P57 3623A processor 250 35011052.06 07/2008 TSX P57 453 processor 27 General characteristics of TSX P57 453 processors TSX P57 453 processor The following table gives the general characteristics of the TSX P 57 453 processor. Reference TSX P57 453 Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of slots with TSXRKY 12EX 86 with TSXRKY 4EX, 6EX, 8EX 110 Functions I/O profile (2) Maximum number of channels Maximum number of connections flexible In-rack discrete I/O 2048 In-rack analog I/O 256 Applications (counting, axis, etc.) 64 Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, Ethernet) 4 Master FIPIO (built-in) 127 Third party field bus 2 AS-i field bus 8 Savable real-time clock 35011052.06 07/2008 yes 251 TSX P57 453 processor Reference TSX P57 453 Memory capacity Processor internal RAM 96K16/176K16(1) PCMCIA memory card (maximum capacity) Application area 512K16 Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Application structure Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Application code execution time for a 1K instruction Internal RAM 100% Boolean 0.07ms 65% Boolean + 35% digital 0.11ms PCMCIA card 100% Boolean 0.07ms 65% Boolean + 35% digital 0.11ms System overhead MAST task 1 ms FAST task 0.20 ms (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. flexible I/O profile (2): the maximum number of discrete I/Os, and applicationspecific and analog channels cannot be accumulated. These area distributed according to a formula. 252 35011052.06 07/2008 TSX P57 453A processor 28 General characteristics of TSX P57 453A processors TSX P57 453A processor 35011052.06 07/2008 The following table gives the general characteristics of the TSX P 57 453A processor. Reference TSX P57 453A Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of slots with TSXRKY 12EX 86 with TSXRKY 4EX, 6EX, 8EX 110 253 TSX P57 453A processor Reference TSX P57 453A Functions I/O profile (2) Maximum number of channels Maximum number of connections Memory capacity Application structure 254 flexible In-rack discrete I/O 2048 In-rack analog I/O 256 Applications (counting, axis, etc.) 64 Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, Ethernet) 4 Master FIPIO (built-in) 127 Third party field bus 2 AS-i field bus 8 Savable real-time clock yes Processor internal RAM 96K16/176K16(1) PCMCIA memory card (maximum capacity) Application area 512K16 Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Application code execution time for a 1K instruction Internal RAM 100% Boolean 0.07ms 65% Boolean + 35% digital 0.11ms PCMCIA card 100% Boolean 0.07ms 65% Boolean + 35% digital 0.11ms System overhead MAST task 1.15 ms FAST task 0.23 ms 35011052.06 07/2008 TSX P57 453A processor (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. flexible I/O profile (2): the maximum number of discrete I/Os, and applicationspecific and analog channels cannot be accumulated. These area distributed according to a formula. 35011052.06 07/2008 255 TSX P57 453A processor 256 35011052.06 07/2008 TSX P57 4823 processor 29 TSX P57 4823 Processors: General Characteristics TSX P57 4823 Processor 35011052.06 07/2008 The following table gives the general characteristics of the TSX P 57 4823 processor. Reference TSX P57 4823 Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of with TSXRKY 12EX slots with TSXRKY 4EX, 6EX, 8EX 86 110 257 TSX P57 4823 processor Reference TSX P57 4823 Functions I/O profile (2) flexible Maximum number of In-rack discrete I/O channels In-rack analog I/O 2048 Applications (counting, axis, etc.) 256 64 Maximum number of Built-in UNI-TELWAY (terminal connections port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, embedded Ethernet (3)) 4 FIPIO master (built-in), number 127 of devices Memory capacity Application structure Application code execution time for a 1K instruction 258 Third party field bus 2 AS-i field bus 8 Savable real-time clock yes Processor internal RAM 96K16/176K16(1) PCMCIA memory card (maximum capacity) 512K16 Application area Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Internal RAM PCMCIA card 100% Boolean 0.07ms 65% Boolean + 35% digital 0.11ms 100% Boolean 0.07ms 65% Boolean + 35% digital 0.11ms 35011052.06 07/2008 TSX P57 4823 processor Reference TSX P57 4823 System overhead MAST task 1 ms FAST task 0.19 ms (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. (2) Flexible I/O profile: the maximum number of discrete I/Os, and applicationspecific and analog channels cannot be accumulated. These area distributed according to a formula. (3) One of which is occupied by the TSX ETY PORT of the CPU. 35011052.06 07/2008 259 TSX P57 4823 processor 260 35011052.06 07/2008 TSX P57 4823A processor 30 TSX P57 4823A Processors: General Characteristics TSX P57 4823A Processor 35011052.06 07/2008 The following table gives the general characteristics of the TSX P 57 4823A processor. Reference TSX P57 4823A Maximum configuration Maximum number of TSX RKY 12EX racks 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of with TSXRKY 12EX slots with TSXRKY 4EX, 6EX, 8EX 86 110 261 TSX P57 4823A processor Reference TSX P57 4823A Functions I/O profile (2) flexible Maximum number of In-rack discrete I/O channels In-rack analog I/O 2048 Applications (counting, axis, etc.) 256 64 Maximum number of Built-in UNI-TELWAY (terminal connections port) 1 Network (ETHWAY, FIPWAY, Modbus Plus, embedded Ethernet (3)) 4 FIPIO master (built-in), number 127 of devices Memory capacity Application structure Application code execution time for a 1K instruction 262 Third party field bus 2 AS-i field bus 8 Savable real-time clock yes Processor internal RAM 96K16/176K16(1) PCMCIA memory card (maximum capacity) 512K16 Application area Symbol Zone 256K16 File area 640K16 channel 0 + 2048K16 channel 1 Master task 1 Fast task 1 Event processing (of which 1 has priority) 64 Internal RAM PCMCIA card 100% Boolean 0.07ms 65% Boolean + 35% digital 0.11ms 100% Boolean 0.07ms 65% Boolean + 35% digital 0.11ms 35011052.06 07/2008 TSX P57 4823A processor Reference TSX P57 4823A System overhead MAST task 1.15 ms FAST task 0.22 ms (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. (2) Flexible I/O profile: the maximum number of discrete I/Os, and applicationspecific and analog channels cannot be accumulated. These area distributed according to a formula. (3) One of which is occupied by the TSX ETY PORT of the CPU. 35011052.06 07/2008 263 TSX P57 4823A processor 264 35011052.06 07/2008 Premium TSX P57/TSX H57 processor: general characteristics 31 At a Glance Aim of this Chapter The aim of this Chapter is to introduce the characteristics of devices that can be used when installing a TSX P57/TSX H57 station. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Electrical Characteristics of TSX P57 Processors 266 Configuration of Premium PL7 Processors 268 Devices which can be connected to or built into the processor 269 Defining and counting application-specific channels 270 265 Premium TSX P57/TSX H57 processor: general characteristics Electrical Characteristics of TSX P57 Processors General As the processors can be fitted with certain devices which do not have their own power supply, the consumption of these devices must be taken into account when establishing a global breakdown of power consumption. Devices without their own power supply which can be connected to the terminal port: z adjustment terminal: T FTX 117 ADJUST, z TSX P ACC01 unit for connecting to the UNI-TELWAY bus. z Devices without their own power supply which can be built into the processor: z PCMCIA communication cards TSX FPP 10/20, z PCMCIA communication card TSX SCP 111/112/114, z PCMCIA communication card TSX MBP 100, z Power Consumption 266 This table shows the consumption of the TSX PSY supply module at 5VDC: Processor + PCMCIA memory card Typical consumption Maximum consumption TSX P57 103 440 mA 610 mA TSX P57 153 530 mA 740 mA TSX P57 203 750 mA 1050 mA TSX P57 253/353LA 820 mA 1140 mA TSX P57 2623 1110 mA 1450 mA TSX P57 2823 1180 mA 1540 mA TSX P57 303/303A 1000 mA 1400 mA TSX P57 353/353A 1060 mA 1480 mA TSX P57 3623/3623A 1360 mA 1800 mA TSX P57 453/453A 1080 mA 1510 mA TSX P57 4823/4823A 1440 mA 1910 mA 35011052.06 07/2008 Premium TSX P57/TSX H57 processor: general characteristics Dissipated Power 35011052.06 07/2008 This table states the dissipated power for TSX P57 processors: Processor + PCMCIA memory card typical maximum TSX P57 103 2.2 W 3.1 W TSX P57 153 2.7 W 3.7 W TSX P57 203 3.8 W 5.3 W TSX P57 253/353LA 4.1 W 5.7 W TSX P57 2623 5.6 W 7.4 W TSX P57 2823 5.9 W 7.8 W TSX P57 303/303A 5.0 W 7.0 W TSX P57 353/353A 5.3 W 7.4 W TSX P57 3623/3623A 6.8 W 9.1 W TSX P57 453/453A 5.4 W 7.6 W TSX P57 4823/4823A 7.2 W 9.7 W 267 Premium TSX P57/TSX H57 processor: general characteristics Configuration of Premium PL7 Processors Specifications A Premium processor comprises: z z selection of processor a dedicated command control processor. The following table gives the general characteristics of the TSXP570244 processors: TSXP57454 processor Original processor TSX P57 103 - General usage Dedicated command processor frequency control processor (MHz) - SONIX Frequency of the dedicated command control processor (MHz). 48 TSX P57 153 - - SONIX 48 TSX P57 203 INTEL or AMD 486 48 SONIX 48 TSX P57 253 INTEL or AMD 486 48 SONIX 48 TSX P57 2623 INTEL or AMD 486 48 SONIX 48 TSX P57 2823 INTEL or AMD 486 48 SONIX 48 TSX P57 303 INTEL or AMD 486 72 SONIX 48 TSX P57 303A INTEL or AMD 486 72 SONIX 48 TSX P57 353 INTEL or AMD 486 72 SONIX 48 TSX P57 353A INTEL or AMD 486 72 SONIX 48 TSX P57 353LA INTEL or AMD 486 48 SONIX 48 TSX P57 3623 INTEL or AMD 486 72 SONIX 48 TSX P57 3623A INTEL or AMD 486 72 SONIX 48 TSX P57 453 INTEL or AMD 486 96 SONIX 48 TSX P57 453A INTEL or AMD 486 96 SONIX 48 TSX P57 4823 INTEL or AMD 486 96 SONIX 48 TSX P57 4823A INTEL or AMD 486 96 SONIX 48 268 35011052.06 07/2008 Premium TSX P57/TSX H57 processor: general characteristics Devices which can be connected to or built into the processor Tables of consumption and dissipated power Consumption: Consumption at 5VDC from the power supply module TSX PSY … Typical Maximum Devices without their own power supply which can be connected to the terminal port (TER) TFTX 117 ADJUST 310mA 340 mA TSXPACC01 150mA 250 mA PCMCIA communication card which can be built into the processor TSXFPP10 330 mA 360 mA TSXFPP20 330 mA 360 mA TSXSCP111 140 mA 300 mA TSXSCP112 120 mA 300 mA TSXSCP114 150 mA 300 mA TSXMBP100 220 mA 310 mA Dissipated power: Dissipated power 35011052.06 07/2008 Typical Maximum Devices without their own power supply which can be connected to the terminal port (TER) TFTX 117 ADJUST 1.5 W 1.7 W TSXPACC01 0.5 W 1.25 W PCMCIA communication card which can be built into the processor TSXFPP10 1.65 W 1.8 W TSXFPP20 1.65 W 1.8 W TSXSCP111 0.7 W 1.5 W TSXSCP112 0.6 W 1.5 W TSXSCP114 0.75 W 1.5 W TSXMBP100 1.1 W 1.55 W 269 Premium TSX P57/TSX H57 processor: general characteristics Defining and counting application-specific channels Summary table Applications: Application Module/card Counting Movement control Applicationspecific channels Number TSXCTY2A Yes 2 TSXCTY2C Yes 2 TSXCTY4A Yes 4 TSXCAY21 Yes 2 TSXCAY41 Yes 4 TSXCAY22 Yes 2 TSXCAY42 Yes 4 TSXCAY33 Yes 3 TSXCSY84 Yes 32 Step by step control TSXCFY11 Yes 1 TSXCFY21 Yes 2 Weighing TSXISPY100 Yes 2 TSXSCP11. in the processor No 0(*) TSXSCP11. in the TSXSCY21. Yes 1 TSXSCP11. in the TSXSCY21. Yes 1 TSXSCY 21 (built-in channel) Yes 1 FIPIO agent TSXFPP10 in the processor No 0(*) Master FIPIO Built into the processor No 0(*) Communication Serial link (*) Although these channels are application-specific, they should not be taken into account when calculating the maximum number of application-specific channels which can be supported by the processor. Note: Only channels configured from PL7 Junior or PL7 Pro software can be counted. 270 35011052.06 07/2008 Processor performance 32 At a Glance Aim of this Chapter This Chapter describes processor performance. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page MAST task cycle time: introduction 272 MAST Task Cycle Time: Program Processing Ppt 273 MAST Task Cycle Time: Input/Output Internal Processing 275 Example of the calculation of cycle times of a MAST task under the following conditions 279 FAST Task Cycle Time 281 Event Response Time 282 271 Processor performance MAST task cycle time: introduction Explanatory diagram The following diagram describes the MAST task cycle time: Program processing I.P on output I.P on input cycle time IP = internal MAST CYCLE TIME = Program processing time (Ppt) + input/output internal processing time (Ipt): 272 35011052.06 07/2008 Processor performance MAST Task Cycle Time: Program Processing Ppt Definition of Ppt Program Processing Time Ppt = Application code execution time (Apcet) + Grafcet overhead time (OtG7). Application Code Execution Time (Apcet) Apcet = sum of the times of each instruction carried out by the application program in each cycle. The execution time of each instruction as well as the type of application which was used to check them are given in the PL7 reference manual. The table opposite gives the execution times in milliseconds (ms) for a 1K instruction (1024 instructions): Processors Application code execution time Apcet (1) Internal RAM PCMCIA card 100% Boolean 65% Boolean + 100% Boolean 65% Boolean + 35% numerical 35% numerical TSX P57 103 TSX P57 153 0.66 ms 0.95 ms 0.83 ms 1.18 ms TSX P57 2•3/2•23/ 353LA TPCX 57 203 0.21 ms 0.28 ms 0.27 ms 0.40 ms TSX P57 3•3/3•3A/ 3623/3623A TPCX 57 353 0.15 ms 0.21 ms 0.22 ms 0.32 ms TSX P57 453/453A/ 4823/4823A 0.07 ms 0.11 ms 0.07 ms 0.11 ms (1) with all the instructions executed in each PLC cycle. 35011052.06 07/2008 273 Processor performance Grafcet Overhead Time (OtG7) OtG7 = GFT + (AST x number of simultaneous active steps) + (OTT x number of transitions occurring simultaneously). Summary table: Processors GFT AST OTT TSX P57 103 TSX P57 153 0.243 ms 0.088 ms 0.359 ms TSX P57 2•3/2•23/353LA TPCX 57 203 0.075 ms 0.029 ms 0.109 ms TSX P57 3•3/3•3A/3623/3623A TPCX 57,353 0.047 ms/ 0.054 ms (A) 0.018 ms/ 0.021 ms (A) 0.069 ms/ 0.079 ms (A) TSX P57 453/453A//4823/4823A 0.039 ms/ 0.045 ms (A) 0.015 ms/ 0.017 ms (A) 0.058 ms/ 0.067 ms (A) GFT: Grafcet time AST: active step time OTT: occurring transition time 274 35011052.06 07/2008 Processor performance MAST Task Cycle Time: Input/Output Internal Processing Definition of Input and Output Internal Processing Time (Ipt) MAST task overhead system time (Mtost) + max [receiving communication system Time (rcomT); management time on input of implicit I/O %I (mTi%I)] Ipt = + max [sending communication system Time (scomT); management time on output of implicit I/O %Q (Mto%Q)] MAST Task Overhead System Time (Mtost) 35011052.06 07/2008 Summary table: Processors Time without FIPIO application Time with FIPIO application TSX 57 103 1.5 ms - TSX 57 153 1.5 ms 3.1 ms TSX P57 203 / 2623 TPCX 57 203 1 ms - TSX P57 253/2823/353LA 1 ms 1.2 ms TSX P57 303/303A/3623/3623A 1 ms/ 1.15 ms (A) - TSX P57 353/353A TPCX 57 353 1 ms/ 1.15 ms (A) 1 ms/ 1.15 ms (A) TSX P57 453/453A/4823/4823A 1 ms/ 1.15 ms (A) 1 ms/ 1.15 ms (A) 275 Processor performance Management Time on Input/ Output of Implicit I/O %I and %Q mTi%I = 60 micro seconds + sum of the IN times of each module. mTo%Q = 60 micro seconds + sum of the OUT times of each module. Management time on input (IN) and on output (OUT) for each module: Type of module Management time On input (IN) On output (OUT) Total (IN+OUT) 8 channel discrete inputs 27 μs - 27 μs 16 channel discrete inputs (all modules except TSX DEY 16FK) 27 μs - 27 μs 32 channel discrete inputs 48 μs - 48 μs 64 channel discrete inputs 96 μs - 96 μs Fast discrete inputs (8 channels used) (module TSX DEY 16FK/TSXDMY 28FK) 29 μs 16 μs 45 μs Fast discrete inputs (16 channels used) (module TSX DEY 16FK/TSXDMY 28FK/ 28RFK) 37 μs 22 μs 59 μs 8 channel discrete outputs 26 μs 15 μs 41 μs 16 channel discrete outputs 33 μs 20 μs 53 μs 32 channel discrete outputs 47 μs 30 μs 77 μs 64 channel discrete outputs 94 μs 60 μs 154 μs Analog inputs (in groups of 4 channels) 84 μs - 84 μs Analog outputs (4 channels) 59 μs 59 μs 118 μs Counting (TSX CTY 2A/4A), by channel 55 μs 20 μs 75 μs Counting (TSX CTY 2C), by channel 65 μs 21 μs 86 μs Step by step control (TSX CFY ..), by channel 75 μs 20 μs 95 μs Axis control (TSX CAY ..), by channel 85 μs 22 μs 107 μs Note: Discrete input/output module times are given in the theory that all channels of the module are assigned to the same task. Example: using module TSX DEY 32 D2 K z if the 32 channels are assigned to the same task, use the «32 channel discrete inputs» time, z if only 16 channels are assigned to the same task, use the «16 channel discrete inputs» time and not the «32 channel discrete input» time divided by 2. 276 35011052.06 07/2008 Processor performance Communication System Time Communication (except telegram) is made during MAST task «Internal Processing» phases: z z on input for receiving messages (rcomT), on outputs for sending messages (scomT). The MAST task cycle time is therefore affected by communication traffic. Communication time through each cycle varies considerably according to: traffic generated by the processor: the number of simultaneously active communication EF, z traffic generated from other devices to the processor or for which the processor provides a traffic routing function like the master. z This time only occurs in the cycles where there is a new message to be managed. Examples of Communication System Time Terminal connected to PL7 Junior software and open animation table Processors Average time per cycle Maximum time per cycle TSX P57 103 / 153 2.5 ms 3.5 ms TSX P57 2•3/2•23/353LA TPCX 57 203 2 ms 2.5 ms TSX P57 3•3/3•3A/3623/3623A TPCX 57 353 1.3 ms / 1.4 ms (A) 1.8 ms / 2.1 ms (A) TSX P57 453/453A/4823/4823A 1 ms / 1.1 ms (A) 1.5 ms / 1.7 ms (A) 1 OF SEND_RQ (mirror request, 100 characters) Instruction execution time: 0.5 ms (for a TSX P57 203 processor), to be included in the application code execution time for cycles where the EF is executed in real-time. 35011052.06 07/2008 277 Processor performance Communication System Time Data table: Processors Sending time Receiving time TSX P57 103 / 153 800 μs 800 μs TSX P57 2•3/2•23/353LA TPCX 57 203 220 μs 220 μs TSX P57 3•3/3•3A/3623/3623A TPCX 57 353 150 μs / 170 μs (A) 150 μs / 170 μs (A) TSX P57 453/453A/4823/4823A 120 μs / 140 μs (A) 120 μs / 140 μs (A) Note: These times cannot be combined in the same cycle. Transmission occurs in the same cycle as instruction execution as long as communication traffic remains light, but the reply is not received in the same cycle. 278 35011052.06 07/2008 Processor performance Example of the calculation of cycle times of a MAST task under the following conditions Introduction An application with the following characteristics: TSX P57 203 processor, Execution of a program in PLC internal RAM, z 10 K instructions: 65% Boolean + 35% numerical, z 1 OF communication type SEND_REQ, z 128 discrete inputs distributed over: 7 TSX DEY 16D2 modules + 1 TSX DEY 16FK module, z 80 discrete outputs distributed over: 5 TSX DSY 16T2 modules, z 32 analog inputs distributed over: 2 TSX AEY 1600 modules, z 16 analog outputs distributed over: 4 TSX ASY 410 modules, z 2 counting channels distributed over: 1 TSX CTY 2A module. z z Calculation of the different times Application code execution time (APCET): z z without communication OF: 10 x 0.28 = 2.8 ms with 1 OF of SEND_REQ type communication (execution of an EF = 2 ms) = (10x0.28) + 2 = 4.8 ms Overhead system time (Ost) = 1ms Input and output management time for implicit I/O %I and %Q: Module product references Module type Number of modules Input management time (IN) Output management time (OUT) TSX DEY 16D2 16 channel discrete inputs 7 238 micro seconds - TSX DEY 16 FK 16 channel discrete inputs (fast inputs) 1 37 micro seconds 22 micro seconds TSX DSY 16T2 16 channel discrete outputs 5 165 micro seconds 100 micro seconds TSX AEY 1600 Analog inputs 2 (32 channels) 672 micro seconds - TSX ASY 410 Analog outputs 4 (16 channels) 236 micro seconds 236 micro seconds TSX CTY 2A Counting 1 (2 channels) 110 micro seconds 40 micro seconds 1458 micro seconds 398 micro seconds Total management time Input management time: Imt%I = 60 microseconds + 1458 microseconds = 1518 microseconds = 1.52 ms. 35011052.06 07/2008 279 Processor performance Output management time: Omt%Q = 60 microseconds +398 microseconds = 458 microseconds = 0.46 ms. Communication system time: z z Sending a request: scomT = 0.22 ms, Receiving the reply: rcomT = 0.22 ms. Cycle time without execution of the communication OF TcyM = Apcet + Most + Imt%I + Omt%Q = 2.8 ms +1 ms + 1.52 ms + 0.46 ms = 5.78 ms Cycle time with execution of the communication OF and sending of the request McyT = Apcet + Texec EF + Most +Imt%I + Omt%Q + scomT = 2.8 ms + 2 ms + 1 ms + 1.52 ms + 0.46 ms + 0.22ms = 8 ms Cycle time with reception of reply Mcyt = Apcet + Texec EF + Most +Imt%I + Omt%Q + rcomT = 2.8 ms + 2 ms + 1 ms + 1.52 ms + 0.46 ms + 0.22ms = 8 ms 280 35011052.06 07/2008 Processor performance FAST Task Cycle Time Definition FAST cycle time = Program processing time (Ppt) + input and output internal processing time (Ipt). Definition of Ppt Program Processing Time Ppt = Application code execution time relative to the FAST (Apcet). Definition of Input and Output Internal Processing Time (Ipt) Ipt = FAST task overhead system time + input and output management time for implicit I/O %I and %Q. Application code execution time: see Application Code Execution Time (Apcet), p. 273. FAST task overhead system time (FosT) Processors FAST task overhead system time TSX P57 103 PCX 57 203 0.8 ms TSX P57 2•3/2•23/353LA TSX P57 3•3/3•3A/3623/3623A PCX 57 353 0.6 ms/ 0.69 ms (A) TSX P57 453/453A/4823/4823A 0.2 ms / 0.23 ms (A) Input and output management time for implicit I/O %I and %Q: see MAST Task Cycle Time: Input/Output Internal Processing, p. 275. 35011052.06 07/2008 281 Processor performance Event Response Time General Definition: time between an edge on an event input and the corresponding edge on an output positioned by the program in the event task. Example: program with 100 Boolean instructions and input module TSX DEY 16 FK Processors Response time Module TSX DSY 08T22 Module TSX DSY 32T2K Minimum Typical Maximum Minimum Typical Maximum TSX P57 103 PCX 57 203 1.2 ms 1.3 ms 2.8 ms 1.9 ms 2.4 ms 4.2 ms TSX P57 2•3/2•23/353LA TSX P57 3•3/3•3A/3623/3623A PCX 57 353 1 ms / 1.1 ms (A) 1.1 ms / 1.2 2.2 ms / 2.4 1.8 ms / 2 ms (A) ms (A) ms (A) 2.2 ms / 2.4 ms (A) 3.7 ms / 4.1 ms (A) TSX P57 453/453A/4823/4823A 0.7 ms / 0.8 ms / 0.9 0.8 ms / 0.9 1.5 ms / 1.7 1.9 ms / 2.1 0.8 ms (A) ms (A) ms (A) ms (A) ms (A) 2.1 ms / 2.3 ms (A) 282 35011052.06 07/2008 Atrium PCX 57 processors IV At a Glance Aim of this Part The aim of this Part is to describe PCX 57 processors and their installation. What's in this Part? This part contains the following chapters: 35011052.06 07/2008 Chapter Chapter Name Page 33 PCX 57 Processors: introduction 285 34 PCX 57 Processors: installation 295 35 PCX 57 processors: Diagnostics 317 36 PCX 57 203 processor 329 37 PCX 57 353 processor 331 38 Atrium PCX 57 CPU: general characteristics 333 283 Atrium PCX 57 processors 284 35011052.06 07/2008 PCX 57 Processors: introduction 33 At a Glance Aim of this Chapter The aim of this Chapter is to introduce PCX 57 processors. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page General introduction 286 Physical description of PCX 57 processors 288 Real-time clock 290 Dimensions of PCX 57 processor cards 291 The different components of a PCX 57 card 292 285 PCX 57 Processors: introduction General introduction At a Glance Integrated into a host PC (1) running Windows 95/98/2000 or Windows NT with a 16-bit ISA bus, PCX 57 processors manage, using PL7 Junior or PL7 Pro software, a complete PLC station made up of racks, discrete input/output modules, analog input/output modules and application modules, which can be distributed over one or more racks connected to an bus X. Note: The PCX 57 processor communicates with the PC in which it is installed via the 16-bit ISA bus. To do this, a communication driver (ISAWAY 95/98/2000 or ISAWAY NY must be installed. Illustration PCX 57 processor Host PC Two types of processor are available to meet your different requirements: PCX 57 203 processor: a processor with specifications and performance identical to the TSX P57 203 processor, z PCX 57 353 processor: a processor with specifications and performance identical to the TSX P57 353 processor. z 286 35011052.06 07/2008 PCX 57 Processors: introduction Characteristics of the host PC To support a PCX 57 processor, the host PC must: operate under Windows 95/98 or Windows NT, have a 16-bit 8 MHz ISA bus, z have two standard slots available on the ISA bus (consecutive and 20.32mm apart), of sufficient height and width. As the shape of the PCX 57 processor card is exactly the same as the shape of a 16-bit ISA PC card, z the host PC must respond to ISA norms (signals, power supply, etc.). z z Note: (1) the term "host PC" means a Schneider Electric industrial PC or any other office PC that has the characteristics defined above. 35011052.06 07/2008 287 PCX 57 Processors: introduction Physical description of PCX 57 processors Illustration 288 This diagram labels the different components of a PCX 57 processor module 35011052.06 07/2008 PCX 57 Processors: introduction Description This table describes the components of a processor module: Number 1 Function RUN, TER, BAT, I/O and FIP LEDs for signaling (the FIP LED is only present on the TPCX 57 353 model). 2 Slot for a PCMCIA type 1 memory extension card. 3 Micro-switches for coding the module’s position on the rack. 4 Micro-switches for coding the rack address on the bus X. 5 Slot for a PCMCIA type 3 communication card. 6 Female 9-pin SUB D connector used to extend the bus X to an extendable rack. 7 Terminal port (TER Connector (8-pin mini-DIN)): this is used to connect an FTX type or PC compatible terminal, or to connect the PLC to the UNI-TELWAY bus through the TSX P ACC 01 insulation unit. This connector is used to supply 5V to the peripheral which is linked to it (limited by the available current provided by the PC’s power supply). 8 Recessed RESET button which leads to a cold startup of the PLC, when it is activated. z Processor working normally: cold startup in STOP or RUN mode, according to the procedure defined in the configuration, z Processor error: forced startup in STOP mode. 9 ERR LED. 10 Male 9-pin SUB D connector for linking up to a master FIPIO bus. This connector is only present on TSX P57 353 processors. 11 16-bit ISA connector, used for linking up to the host PC. 12 Micro-switches for coding the PCX 57 processor address on the ISA bus (I/O space). 13 Contacts for selecting the interrupt (IRQ..), used by the processor on the ISA bus. 14 Slot for a battery which allows that the processor’s internal RAM memory to be saved. The RESET button must be pressed using a non-conductive object. Note: The TER terminal port offers master UNI-TELWAY communication mode by default, and can be configured for slave UNI-TELWAY or ASCII character mode. 35011052.06 07/2008 289 PCX 57 Processors: introduction Real-time clock At a Glance PCX 57 processors have a real-time clock. See Real-time clock, p. 153 in the TSX P57 Premium processor section. 290 35011052.06 07/2008 PCX 57 Processors: introduction Dimensions of PCX 57 processor cards Diagrams The various following diagrams show the dimensions, in millimeters, of PCX 57 processor cards. 249 Note: A PCX 57 processor uses two slots on the PC ISA bus. These slots must be adjacent and 20.32mm apart. 35011052.06 07/2008 291 PCX 57 Processors: introduction The different components of a PCX 57 card Illustration This diagram shows the various components which make up a PCX 57 processor card 1 3 4 2 5 6 292 35011052.06 07/2008 PCX 57 Processors: introduction Table of components and their descriptions The following table gives the names and descriptions of the various components which make up the PCX 57 processor card: Address Element Description 1 PCX 57 processor card associated with a mechanical sub-assembly used to house a PCMCIA type 3 communication card. 2 battery the battery (see Changing the PCX 57 RAM memory backup battery, p. 320) allows the processor RAM memory to be saved, and it should be mounted in the appropriate slot on the processor card. 3 line terminator TSX TLYEX /B (see Line terminator TSX TLYEX, p. 105) line terminator. 4 removable cover a removable cover for a PCMCIA communication card specific to the PCX 57 processor. 5 shield shield equipped with a 9-pin SUB D connector to link a TSX CBY..0K (see TSX CBY..0K bus X extension cable (II ≥ 02), p. 100) bus X extension cable, and a cable for linking to the PCX 57 processor. This accessory is for connecting the PCX 57 processor inside a section of the bus X. 6 daughterboard interfaces between the above shield and the PCX 57 processor card. This accessory should be used with the above shield. It is fitted instead of the A/ line terminator which is built into the processor as standard. Note: In addition to the components given above, the following are provided with the PCX 57 card: z diskettes containing the ISAWAY drivers and OFS software package, z instructions for installing the PCX 57 processor. 35011052.06 07/2008 293 PCX 57 Processors: introduction 294 35011052.06 07/2008 PCX 57 Processors: installation 34 At a Glance Aim of this Chapter This Chapter deals with the installation of PCX 57 processors and the PCMCIA extension card. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Precautions to be taken during installation 296 Physical installation of the PCX 57 processor in the PC 297 Logical installation of the PCX 57 processor on the bus X 298 Operations to be carried out before installation 301 How to configure the PCX 57 processor address on the bus X 302 How to configure the processor’s standard I/O address on the ISA bus 304 How to install the PCX 57 processor card in the PC 308 Integrating a PCX 57 processor into an bus X section 310 How to install/remove the memory extension card on the PCX 57 processor 313 Processing on insertion/extraction of a PCMCIA memory card on a PCX 57 PLC 314 Memory cards for PCX 57 processors 315 Precautions to be taken when replacing a PCX 57 processor 316 295 PCX 57 processors: installation Precautions to be taken during installation General You are advised to limit charges of static electricity, which can cause significant damage to electronic circuits. To do this the following rules should be observed: CAUTION ELECTROSTATIC DISCHARGE hold the card by the edges. Do not touch the connectors or any of the circuits that are visible, z do not take the card out of its protective anti-static packaging before you are ready to install it in the PC, z ground yourself during handling, if possible, z do not put the card on a metal surface, z avoid unnecessary movements, as static electricity is generated by clothing, carpets and furniture. z Failure to follow these instructions can result in injury or equipment damage. 296 35011052.06 07/2008 PCX 57 processors: installation Physical installation of the PCX 57 processor in the PC General The PCX 57 processor physically occupies two consecutive slots, slots 1 and 2, on the ISA bus but only uses one of them, slot 1, electrically. Slot 2 is used by the PCMCIA communication card. Illustration Diagram showing the principle: Note: two PCX 57 processors can be installed in the same PC. 35011052.06 07/2008 297 PCX 57 processors: installation Logical installation of the PCX 57 processor on the bus X Logical installation on the Bus X The PCX 57 processor logically occupies the same slot as a TSX P57 processor (rack with address 0, position 00 or 01). The TSX RKY••EX rack with address 0 must have a power supply module and the position which is normally taken up by a TSX P57 processor will be unoccupied (virtual slot for the PCX 57 processor). Premium PLCs have two types of power supply (standard and double format). The unoccupied position on the rack with address 0 will be depend upon the type of power supply used. Note: z The slot corresponding to the PCX 57 processor address (physically free on the rack) must not be used by another module. z The bus X address (see How to configure the PCX 57 processor address on the bus X, p. 302) must be configured using the micro-switches on the processor card, so that the PCX 57 processor is aware of its address on the bus X. 298 35011052.06 07/2008 PCX 57 processors: installation Using a standard format power supply module In this case, the installation rule for the rack with address 0 is as follows: the power supply module automatically occupies position PS, position 00, the virtual slot for the processor, must be unoccupied, z the other modules are installed starting at position 01. z z The following diagram shows the module installation rule when a single format power supply module is used. TSX RKY••EX rack at address x Rack address: 00 Address position: 00 TSX RKY••EX rack at address y TSX RKY••EX rack at address 0 35011052.06 07/2008 299 PCX 57 processors: installation Using a double format power supply module In this case, the installation rule for the rack with address 0 is as follows: the power supply module automatically occupies positions PS and 00, position 01, the virtual slot for the processor, must be unoccupied, z the other modules are installed starting from position 02. z z The following diagram shows the module installation rule when a single format power supply module is used. TSX RKY••EX rack at address x Rack address: 0 Address position: 01 TSX RKY••EX rack at address 0 TSX RKY••EX rack at address y 300 35011052.06 07/2008 PCX 57 processors: installation Operations to be carried out before installation General Certain operations must be performed before a processor card is installed in the PC: if necessary, insert the battery into the slot provided (see Changing the PCX 57 RAM memory backup battery, p. 320), z if necessary, insert the PCMCIA memory card (see How to install/remove the memory extension card on the PCX 57 processor, p. 313), z configure the address of the processor on the bus X (see How to configure the PCX 57 processor address on the bus X, p. 302), z configure the processor’s standard I/O address on the ISA bus (see How to configure the processor’s standard I/O address on the ISA bus, p. 304). z 35011052.06 07/2008 301 PCX 57 processors: installation How to configure the PCX 57 processor address on the bus X General points This address must be the same as the one which will be configured in the configuration screen of the PL7 Junior or PL7 Pro software. This configuration is carried out using micro-switches found on the processor card. Rack address: the processor’s virtual slot is always situated on the rack with address 0. Processor position: the virtual position of the processor will depend upon the type of power supply installed on the rack: z z single format power supply: virtual position of processor = 00, double format power supply: virtual position of processor = 01. Default configuration: z z 302 rack address = 0, module position = 00. 35011052.06 07/2008 PCX 57 processors: installation Illustration Explanatory diagrams: Coding Value processor, here: 00 Coding address rack, here: 0 PCX ADD RACK ADD Position of the RACK ADD micro-switches in relation to the rack address: Rack Position of the microswitches PCX ADD 0 1 2 3 4 5 6 7 Addresses not used Position of the PCX ADD micro-switches in relation to the processor’s position on the rack: Position of the 00 01 processor Position of the microswitches PCX ADD 35011052.06 07/2008 303 PCX 57 processors: installation How to configure the processor’s standard I/O address on the ISA bus General points The PCX 57 processor uses: z z eight consecutive addresses in the ISA bus’s I/O space, an interrupt (IRQ..). Before configuring the PCX 57 processor, it is a good idea to establish an I/O space and an available IT in the PC using the standard utilities under Windows 95/98 or Windows NT. When the available resources are determined, PCX 57 is configured as follows: z z the standard address of the PCX 57 processor on the ISA bus is configured, the interrupt used by the processor on the ISA bus is configured (IRQ..). CAUTION IMPROPER CONFIGURATION An improper configuration can lead to the PC malfunctioning. Failure to follow these instructions can result in injury or equipment damage. 304 35011052.06 07/2008 PCX 57 processors: installation Configuring the standard address of the PCX 57 processor on the ISA bus This configuration is carried out using the 6 micro-switches located near the PCX 57’s ISA connector. They represent from left to right the bits with addresses SA9 to SA4. The address H‘220’ is configured by default. Note: This address must be the same as the one which will be configured in the configuration screen of the ISAWAY driver. Illustration: the PCX 57 card and its micro-switches which are used to configure the address 35011052.06 07/2008 305 PCX 57 processors: installation Example of PCX 57 address coding on the ISA bus This table shows various address codings Switch Coding of the address 9 8 7 6 5 4 3 2 1 0 H’000’ 0 0 0 0 0 0 0 0 0 0 0 H’110’ 1 0 1 0 0 0 1 0 0 0 0 H’220’ 2 1 0 0 0 1 0 0 0 0 0 H’330’ 3 1 1 0 0 1 1 0 0 0 0 4 0 1 0 0 0 0 0 0 5 0 1 0 1 0 0 0 0 6 0 1 1 0 0 0 0 0 7 0 1 1 1 0 0 0 0 8 1 0 0 0 0 0 0 0 9 1 0 0 1 0 0 0 0 To 1 0 1 0 0 0 0 0 B 1 0 1 1 0 0 0 0 C 1 1 0 0 0 0 0 0 D 1 1 0 1 0 0 0 0 E 1 1 1 0 0 0 0 0 F 1 1 1 1 0 0 0 0 Illustration: coding using the micro-switches 306 35011052.06 07/2008 PCX 57 processors: installation Configuring the interrupt used by the processor on the ISA bus (IRQ..) This is configured using a jack-plug which should be placed over the interrupt to be selected. IRQ 10 is selected by default. Illustration: PCX 57 card with micro-switches which are used to configure the IRQ. 35011052.06 07/2008 307 PCX 57 processors: installation How to install the PCX 57 processor card in the PC Preliminary conditions Preliminary addressing operations (see Operations to be carried out before installation, p. 301) must be performed. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Disconnect all power before servicing equipment. When installing the processor in the PC, the PC must always be switched off. Failure to follow these instructions will result in death or serious injury. 308 35011052.06 07/2008 PCX 57 processors: installation Procedure to be followed The following table describes the procedure for installing the processor card in the PC: Step 1 Action Once the PC’s electrical power supply has been switched off, remove the computer casing and find two free adjacent ISA slots. As an installation constraint, the PC must conform to the following standard: PC 20,32mm Emplacement ISA 1 35011052.06 07/2008 Emplacement ISA 2 2 Remove the protective covers and mounting screws already in place which correspond to the available slots. 3 Install the card in the planned free slots. 4 Fix the card to the PC by tightening the mounting screws you removed previously. 5 Place the casing back on the computer again and replace all the cables and accessories which had to be switched off: z Bus X cable and /B line terminator TSX TLYEX Important: The processor switches to a blocking fault, if the line terminator / B is not installed: z on the PCX 57 processor, if this is not linked to a rack by a TSX CBY .. bus X cable. . In this case, a /B line terminator (see Line terminator TSX TLYEX, p. 105) must be installed on the processor’s bus X output. z on the available connector of the last rack of the station, if the PCX 57 processor is linked to a rack by a TSX CBY .. bus X cable. . In this case, a /B line terminator must be installed. This device is used to show that the bus X has not been adapted. z FIPIO Bus cable and PCMCIA communication card, if necessary. 6 Switch the PC on and start installing the various software packages: z ISAWAY driver which corresponds to the OS installed: WINDOWS 95/98 or Windows NT, (see the service instructions provided with the processor), z OFS data server if used, z PL7 Junior or PL7 Pro software if used. 309 PCX 57 processors: installation Integrating a PCX 57 processor into an bus X section General As standard, the PCX 57 processor is equipped to be built into the start of the X Bus line, and for this reason it has a built-in A/ line terminator. If you want to integrate the processor into an bus X section, the module is supplied with two accessories which make this possible: a shield equipped with: z a 9-pin SUB D connector for linking up a TSX CBY• bus X cable, z a cable for connecting the 9-pin SUB D connector to the processor card, z a daughterboard equipped with two connectors which interface between the PCX 57 card and the 9-pin SUB D connector of the aforementioned shield. This daughterboard is fitted instead of the A/ line terminator, mounted on the PCX 57 card as standard. z Illustration Shield and daughterboard: Shield Daughterboard 310 35011052.06 07/2008 PCX 57 processors: installation Installation procedure 35011052.06 07/2008 Carry out the following steps Step Action 1 Remove the A/ line terminator from its slot on the processor. 2 Fit the daughterboard in place of the A/ line terminator. 3 Once the processor card is in place in the PC, fix the shield in the available slot situated immediately to the left of the processor card, as indicated in the diagram below. 4 Connect the cable to the connector of the daughterboard which was installed in step 2 Illustration 311 PCX 57 processors: installation Example of the topology of a PCX 57 station with the processor integrated in an bus X section Diagram Host PC PCX 57 PCX 57 Note: In this example, as the PCX 57 processor is no longer integrated at the start of the line, the TSX TLY EX A/ and /B line terminators must be installed on each of the racks situated at the end of the lines. 312 35011052.06 07/2008 PCX 57 processors: installation How to install/remove the memory extension card on the PCX 57 processor Principle Perform the following steps to install the memory card on the PCX 57 processor: Step Action 1 Place the PCMCIA card in its allocated slot. 2 Slide it in until it can go no further. 3 Position the card in the PC with the power turned off. CAUTION INSTALLING MEMORY EXTENSION CARD WITH POWER ON The memory extension card must be installed on the processor card with the power switched off and before the processor card is installed in the PC. Failure to follow these instructions can result in injury or equipment damage. Illustration Explanatory diagram: Note: If the program in the PCMCIA memory cartridge contains the RUN AUTO option, the processor will automatically restart in RUN mode after the cartridge is inserted and the PC is turned on. 35011052.06 07/2008 313 PCX 57 processors: installation Processing on insertion/extraction of a PCMCIA memory card on a PCX 57 PLC General WARNING UNEXPECTED EQUIPMENT OPERATION Do no insert or extract the PCMCIA memory card into or from a PCX 57 when it is powered-up. These actions, although they will not damage the processor or any other device, will cause random processor behavior. Failure to follow these instructions can result in death, serious injury, or equipment damage. WARNING UNEXPECTED EQUIPMENT OPERATION If the program contained in the PCMCIA memory card includes the RUN AUTO option, the processor will automatically restart in RUN mode after the card is inserted and the PC is switched on. Failure to follow these instructions can result in death, serious injury, or equipment damage. 314 35011052.06 07/2008 PCX 57 processors: installation Memory cards for PCX 57 processors General 35011052.06 07/2008 See Standard and Backup Memory Cards for PLCs, p. 168 and Application + Files Type Memory Cards, p. 171: 315 PCX 57 processors: installation Precautions to be taken when replacing a PCX 57 processor Important WARNING UNEXPECTED EQUIPMENT OPERATION If the PCX P57 processor is being replaced by another processor which is not blank (the processor has already been programmed and contains an application), the power for all the PLC station’s control units must be switched off. Before restoring power to the control units, check that the processor contains the required application. Failure to follow these instructions can result in death, serious injury, or equipment damage. 316 35011052.06 07/2008 PCX 57 processors: Diagnostics 35 At a Glance Aim of this Chapter This Chapter deals with PCX 57 processor diagnostics. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Description of PCX 57 processor LEDs 318 Changing the PCX 57 RAM memory backup battery 320 Changing the PCX 57 RAM memory PCMCIA card battery 323 What happens after you press the processor RESET button 325 How the PCX 57 behaves after an action on the PC 326 Finding errors via the processor status LEDs 327 317 PCX 57 processors: Diagnostics Description of PCX 57 processor LEDs Labeling of the LEDs Six LEDs (RUN, TER, BAT, I/O, FIP and ERR) found on the processor card enable fast diagnostics of the status of the PLC station. Due to the small amount of space available on the shield, only the ERR LED is visible when the PC housing the processor is closed. To make it more user-friendly, the state of the RUN, I/O, ERR and FIP LEDs is displayed via a utility in the task bar in Windows 95/98 or Windows NT on the PC with the processor card. This functionality is only available when the host PC is running (ISAWAY driver installed) 318 35011052.06 07/2008 PCX 57 processors: Diagnostics Description The following table describes the role of each LED: Display LED Lit BAT (red) z battery missing, Flashing Off - running normally. z battery flat, z battery the wrong way round, z wrong type of battery. RUN (green) PLC running normally, program executing. PLC in STOP mode or blocked by software error. z PLC not configured: TER (yellow) - terminal port link active. The rate of flashing is relative to the amount of traffic. link not active. I/O (red) input/output errors Bus X error (1). coming from a module, a channel or a configuration error. normal state, no internal error. FIP (yellow) - FIPIO bus link active. The rate of flashing is relative to the amount of traffic. link not active. ERR (red) processor or system error. z PLC not configured normal state, no internal error. (application missing, invalid or incompatible), z PLC blocked by a software error, z memory card battery error, z Bus X error (1). application missing, invalid or incompatible, z PLC error: processor or system error. Note: z (1) a bus X error is indicated by simultaneous flashing of the ERR and I/O LEDs. z the FIP LED is only present on TPCX P57 353 processor. 35011052.06 07/2008 319 PCX 57 processors: Diagnostics Changing the PCX 57 RAM memory backup battery Introduction This battery on the PCX 57 processor module ensures that the processor internal RAM memory and the real-time clock are saved in the event of a power outage. It is delivered in the same packaging as the processor and must be installed by the user. Note: With a PCX 57 processor, there is no point in putting a battery into the rack power supply which usually houses the processor (rack with address 0). Installing the battery for the first time Changing the battery To install the battery, carry out the following: Step Action 1 Remove the cover by squeezing the sides. 2 Put the battery in its slot taking care to observe polarities. 3 Replace the cover which keeps the battery in its slot. The battery can be changed every year as a preventative measure or when the BAT LED is lit. However the LED is not visible when the PC is closed, but you have a %S68 system bit (0 = backup battery OK) which can be used by the application program to generate an alarm to warn that the battery needs changing. To change the battery, carry out the following: Step 320 Action 1 Switch the PC off. 2 Disconnect the different cables linked to the processor. 3 Open the PC. 4 Take the card out of its slot. 5 Remove the cover. 6 Remove the old battery from its slot. 7 Put in the new battery, observing the polarities. 8 Replace the cover. 9 Put the card back in its slot, close the PC, connect external components and switch on. 35011052.06 07/2008 PCX 57 processors: Diagnostics CAUTION PROLONGED BATTERY CHANGE TIME Changing the battery should not exceed the limit stated in this document for the PC being switched off. Exceeding this limit may cause data in RAM memory to be lost. Failure to follow these instructions can result in injury or equipment damage. Illustration The following diagram shows how the battery is installed: 1: cover 2: battery 35011052.06 07/2008 321 PCX 57 processors: Diagnostics How often must the battery be changed? Period of battery backup The length of time during which the battery ensures backup of the processor’s internal RAM memory and the real-time clock depends on two factors: the percentage of time for which the PLC is switched off and as a result the battery is being used, z the ambient temperature when the PLC is switched off. z Summary table: ≤ 30°C 40°C 50°C 60°C PLC off for 12 hours 5 years per day 3 years 2 years 1 year PLC off for 1 hour per day 5 years 4.5 years 4 years Ambient temperature when inoperative Backup time 5 years Independent saving by the processor The processors have their own offline independent save function to save the processor internal RAM memory and the real-time clock, which allows the removal of: z the PCX 57 processor battery. The backup time depends on the ambient temperature. Assuming that the processor was switched on previously, the guaranteed time varies in the following way: 322 Ambient temperature when switching off 20°C 30°C 40°C 50°C Backup time 2h 45mn 20mn 8mn 35011052.06 07/2008 PCX 57 processors: Diagnostics Changing the PCX 57 RAM memory PCMCIA card battery Introduction RAM memory PCMCIA cards (TSX MRP etc.) must have a battery (reference TSX BAT M01) which needs to be changed. How to change the battery Carry out the following steps: Illustration Step Action 1 Take the card out of its slot. 2 Hold the PCMCIA card so you can access the battery slot. This is at the end of the card without the connector. 3 Unlock the battery holder, which is at the end of the card without the connector. To do this press the lock towards the bottom of the card (the opposite direction to the write protection micro-switch) while pulling towards the back. 4 Remove the battery and holder unit from its slot. 5 Swap the old battery for an identical 3V battery. Polarities must be observed by placing the + labels on the holder and the battery on the same side. 6 Place the battery and holder unit back in its slot, then lock it. To do this, carry out the removal procedure in reverse. 7 Put the memory card back in its allocated slot on the PCX 57 card. Principle diagram: Write protection Lock Battery slot Number 35011052.06 07/2008 323 PCX 57 processors: Diagnostics Battery life See the following table: PCMCIA card stored in normal conditions (-20°C to 70°C) 12 months PCMCIA card fitted in an operating PLC (0°C à 60°C). 36 months Note: During operation, the processor’s ERR LED flashes if the PCMCIA card battery is old. 324 35011052.06 07/2008 PCX 57 processors: Diagnostics What happens after you press the processor RESET button General All processors have a RESET button on their front panel, which when pressed, causes a PLC cold start, in RUN or in STOP mode (1), in the application contained on the memory card (or in internal RAM). RESET following a processor fault As soon as a processor fault appears, the alarm relay on rack 0 (2) is deactivated (open contact) and the module outputs switch to fallback position or are maintained in the current state depending on the selection made at configuration. Pressing the RESET button causes the PLC, forced into STOP mode, to cold start. (1) Start in RUN or in STOP mode is defined at configuration. (2) With the PCX 57 processor, this relay is not controlled. Note: When the RESET button is pressed, and during the PLC cold start, the terminal link is deactivated. 35011052.06 07/2008 325 PCX 57 processors: Diagnostics How the PCX 57 behaves after an action on the PC General The following table describes the different actions on the PC and what implications they have for the PCX 57: Action on the PC PCX 57 behavior Switching off/on warm restart if the application environment has not changed Micro-outages on the network supplying the PC As the PCX 57 does not have a filtering mechanism for microoutages, every micro-outage not filtered by the PC’s internal power supply causes a warm restart of the PCX 57, if the application environment has not changed Pressing the RESET button generally, and subject to the PC’s RESET button activating the RSTDRV signal on the ISA bus, pressing the PC RESET button causes a warm restart of the PCX 57, if the application environment has not changed. PC’s software RESET (CTRL ALT DEL) these actions have no effect on the current state of the PCX 57 processor (if the PCX 57 processor is in RUN, it stays in , etc.) and does not cause a warm restart or cold restart Note: A PC software blockage has no effect on the current state of the PCX 57 processor (identical behavior to a PC software RESET). 326 35011052.06 07/2008 PCX 57 processors: Diagnostics Finding errors via the processor status LEDs General See: Finding errors using processor state LEDs, p. 205, Non blocking errors, p. 206, z Blocking errors, p. 208, z Processor or system errors, p. 209. z z 35011052.06 07/2008 327 PCX 57 processors: Diagnostics 328 35011052.06 07/2008 PCX 57 203 processor 36 General characteristics of the PCX 57 203 processor PCX 57 203 processor The following table gives the general characteristics of the PCX 57 203 processor. Reference PCX 57 203 Maximum configuration Maximum number of TSX RKY 12EX racks Functions Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of slots with TSXRKY 12EX 87 with TSXRKY 4EX, 6EX, 8EX 111 Maximum number of channels In-rack discrete I/O 1024 In-rack analog I/O 80 Maximum number of connections Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, Modbus+) 1 Master FIPIO (built-in) - Third party field bus 1 AS-i field bus 4 Application (counting, axis, etc.) 24 Savable real-time clock 35011052.06 07/2008 8 yes 329 PCX 57 203 processor Reference PCX 57 203 Memory capacity Savable internal RAM Application structure PCMCIA memory card (maximum capacity) Application area Symbol Zone - File area 128K16 or 640K16 1 Fast task 1 Event processing (of which 1 has priority) 100% Boolean 64 0.21 ms 65% Boolean + 35% digital 0.28 ms 100% Boolean 0.27 ms 65% Boolean + 35% digital 330 160K16 Master task Application Internal RAM code execution time for a 1K PCMCIA card instruction System overhead 48K16 0.40 ms MAST task 1 ms FAST task 0.35 ms 35011052.06 07/2008 PCX 57 353 processor 37 General characteristics of the PCX 57 353 processor PCX 57 353 processor The following table introduces the general characteristics of the PCX 57 353 processor. Reference PCX 57 353 Maximum configuration Maximum number of TSX RKY 12EX racks Functions 35011052.06 07/2008 8 Maximum number of TSX RKY 4EX/6EX/8EX racks 16 Maximum number of slots with TSXRKY 12EX 87 with TSXRKY 4EX, 6EX, 8EX 111 Maximum number of channels In-rack discrete I/O 1024 In-rack analog I/O 128 Maximum number of connections Built-in UNI-TELWAY (terminal port) 1 Network (ETHWAY, FIPWAY, Modbus+) 3 FIPIO master (built-in), number of devices 127 Third party field bus 2 AS-i field bus 8 Application (counting, axis, etc.) 32 331 PCX 57 353 processor Reference PCX 57 353 Savable real-time clock yes Memory capacity Savable internal RAM 80K16 or 96K16 (1) PCMCIA memory Application area card (maximum Symbol Zone capacity) File area 384K16 Master task 1 Application structure 128K16 or 640K16 Fast task 1 Event processing (of which 1 has priority) 64 Application Internal RAM code execution time for a 1K PCMCIA card instruction System overhead - 100% Boolean 0.15 ms 65% Boolean + 35% digital 0.21 ms 100% Boolean 0.22 ms 65% Boolean + 35% digital 0.32 ms MAST task 1 ms FAST task 0.25 ms (1) 1st figure when the application is in internal RAM, 2nd figure when the application is in card memory. 332 35011052.06 07/2008 Atrium PCX 57 CPU: general characteristics 38 At a Glance Aim of this Chapter The aim of this Chapter is to introduce you to the characteristics of devices that can be used when installing a PCX 57 station. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Electrical characteristics of PCX 57 processors 334 Characteristics of Atrium PL7 processors 335 Devices which can be connected to or built into the processor 336 Defining and Counting Application-specific channels 337 Processor performance 338 333 Atrium PCX 57 CPU: general characteristics Electrical characteristics of PCX 57 processors General As the processors can be fitted with certain devices which do not have their own power supply, the consumption of these devices must be taken into account when establishing a global breakdown of power consumption. Devices without their own power supply which can be connected to the terminal port: z adjustment terminal: T FTX 117 ADJUST, z unit TSX P ACC01 for connecting to the UNI-TELWAY bus. z Devices without their own power supply which can be built into the processor: z PCMCIA communication cards TSX FPP 10/20, z PCMCIA communication card TSX SCP 111/112/114, z PCMCIA communication card TSX MBP 100, z PCMCIA modem card TSX MDM 10. z Feature of PCX 57 processors PCX 57 processors have their own 5VDC power supply, which is generated from the host PC’s 12 VDC power supply. As a result of this, the 12 VDC power supply from the host PC must have sufficient power to accommodate a PCX 57 processor. Power consumption This table shows consumption of the host PC at 12VDC: Dissipated power 334 Processor + PCMCIA memory card Typical consumption Maximum consumption TPCX P57 203 400 mA 560 mA TPCX P57 353 550 mA 770 mA This table states the dissipated power for PCX 57 processors: Processor + PCMCIA memory card Typical consumption Maximum consumption TPCX P57 203 4,8W 6,72W TSX P57 353 6,6W 9,24W 35011052.06 07/2008 Atrium PCX 57 CPU: general characteristics Characteristics of Atrium PL7 processors Specifications Behavior of the Atrium processor z z selection of processor a dedicated command control processor. The following table gives the general characteristics of the TSXP570244 processors. TSXP57454 processor Original processor General usage Dedicated command Frequency of the processor frequency control processor dedicated command (MHz) control processor (MHz). T PCX 57 203 INTEL or AMD 486 48 SONIX 48 T PCX 57 353 INTEL or AMD 486 72 SONIX 48 35011052.06 07/2008 335 Atrium PCX 57 CPU: general characteristics Devices which can be connected to or built into the processor Tables of consumption and dissipated power Consumption: Consumption at 12VDC from host PC Typical Maximum Devices without their own power supply which can be connected to the terminal port (TER) TFTX 117 ADJUST 144 mA 157 mA TSXPACC01 69 mA 116 mA PCMCIA communication card which can be built into the processor TSXFPP10 153 mA 167 mA TSXFPP20 153 mA 167 mA TSXSCP111 65 mA 139 mA TSXSCP112 56 mA 139 mA TSXSCP114 69 mA 139 mA TSXMBP100 102 mA 144 mA TSXMDM10 90 mA - Dissipated power: Dissipated power 336 Typical Maximum Devices without their own power supply which can be connected to the terminal port (TER) TFTX 117 ADJUST 1.7 W 1.9 W TSXPACC01 0.8 W 1.4 W PCMCIA communication card which can be built into the processor TSXFPP10 1.8 W 2.0 W TSXFPP20 1.8 W 2,0W TSXSCP111 0.8 W 1.7 W TSXSCP112 0.7 W 1.7 W TSXSCP114 0.8 W 1.7 W TSXMBP100 1.2 W 1.7 W TSXMDM10 1.1 W - 35011052.06 07/2008 Atrium PCX 57 CPU: general characteristics Defining and Counting Application-specific channels Summary table Applications: Application Counting Movement commands Step by step control Weighing Communication Serial link Modem FIPIO agent Master FIPIO Module/card Applicationspecific channels Number TSXCTY2A Yes 2 TSXCTY2C Yes 2 TSXCTY4A Yes 4 CCY 1128 Yes 1 TSXCAY21 Yes 2 TSXCAY41 Yes 4 TSXCAY22 Yes 2 TSXCAY42 Yes 4 TSXCAY33 Yes 3 CSY 84 Yes 32 TSXCFY11 Yes 1 TSXCFY21 Yes 2 TSXISPY100 / TSXISP101 Yes 2 TSXSCP11. in the processor No 0(*) TSXSCP11. in the TSXSCY21. Yes 1 TSXSCP11. in the TSXSCY21. Yes 1 TSXSCY 21 (built-in channel) Yes 1 TSXMDM10 Yes 1 TSXFPP10 in the processor No 0(*) Built into the processor No 0(*) (*) Although these channels are application-specific, they should not be taken into account when calculating the maximum number of application-specific channels which can be supported by the processor. Note: Only channels configured from PL7 Junior or PL7 Pro software can be counted. 35011052.06 07/2008 337 Atrium PCX 57 CPU: general characteristics Processor performance General 338 See Processor performance, p. 271: 35011052.06 07/2008 TSX PSY supply modules V At a Glance Subject of this Part This part describes TSX PSY ... supply modules and their implementation. What's in this Part? This part contains the following chapters: 35011052.06 07/2008 Chapter Chapter Name Page 39 TSX PSY… supply modules: introduction 341 40 TSX PSY … supply modules: installation 347 41 TSX PSY … supply modules: diagnostics 367 42 TSX PSY … supply modules : auxiliary functions 375 43 TSX PSY power supply modules: breakdown of power consumption and power 381 44 TSX PSY 2600 power supply module 391 45 TSX PSY 5500 power supply module 393 46 TSX PSY 8500 power supply module 395 47 TSX PSY 1610 power supply module 397 48 TSX PSY 3610 power supply module 399 49 TSX PSY 5520 power supply module 401 339 TSX PSY... supply modules 340 35011052.06 07/2008 TSX PSY… supply modules: introduction 39 At a Glance Aim of this Chapter The aim of this Chapter is to introduce the TSX PSY… supply modules . What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page General introduction 342 Supply modules: description 344 341 TSX PSY…supply modules : introduction General introduction At a Glance TSX PSY… supply modules are designed to supply each TSX RKY… rack and its modules. The supply module is chosen according to the distribution network (direct or alternating current) and the power required (standard or double format model). There are several types of supply modules: z z Auxiliary functions of supply modules Supply modules for an alternating current network supply modules for an alternating current network, supply modules for a direct current network. Each supply module has auxiliary functions: a display panel, an alarm relay, z a slot for a battery for saving the data in the processor’s RAM memory, z a recessed button which, when pressed, simulates a power-supply outage, and launches a warm restart of the application, z a 24 VDC sensor supply (only on models supplied from an alternating current network). z z The following table displays the types of supply module according to their format: Standard format model Double format model TSX PSY 2600 100...240 VCA TSX PSY 5500 100...120 VCA 342 TSX PSY 8500 200...240 VCA 35011052.06 07/2008 TSX PSY…supply modules : introduction Supply modules for a direct current network The following table displays the types of supply module according to their format: Standard format model Double format model TSX PSY 1610 24 VCC non-insulated TSX PSY 3610 24 VCC non-insulated 35011052.06 07/2008 TSX PSY 5520 24...48 VCC insulated 343 TSX PSY…supply modules : introduction Supply modules: description At a Glance The supply models take the form of: z z Illustration standard format modules, for TSX PSY 2600 and TSX PSY 1610 modules, double format modules for TSX PSY 5500/3610/5520/8500 modules. These illustrations label the different components of a standard supply module and a double format supply module: Standard format 344 Double format 35011052.06 07/2008 TSX PSY…supply modules : introduction Description This table describes the components of a supply module: Number Function 1 Display block containing: z an OK LED (green), lit if the voltages are present and correct, z a BAT LED (red), lit when the battery is worn out or missing, z a 24V LED (green), lit when the voltage sensor is present. This LED is only present on alternating current supply modules TSX PSY 2600/5500/8500. 2 Recessed RESET button which, when pushed, triggers a warm restart of the application. 3 Slot for a battery which allows the processor’s internal RAM memory to be saved. 4 Flap for protecting the front panel of the module. 5 Screw terminal block for linking up to: z the supply network, z the alarm relay contact, z the sensor supply for alternating current supply modules TSX PSY 2600/ 5500/8500. 6 7 Hole for a cable-tightening clip to go through. Fuse located under the module protecting: z the 24VR voltage on the direct current supply module TSX PSY 3610, z the primary voltage on the direct current supply module TSX PSY 1610, Note: on the TSX PSY 2600/5500/5520/8500 supply modules, the primary voltage protection fuse is inside the module and cannot be accessed. 8 35011052.06 07/2008 110/220 voltage selector, only present on alternating current supply modules TSX PSY 5500/8500. On delivery, the selector is set to 220. 345 TSX PSY…supply modules : introduction 346 35011052.06 07/2008 TSX PSY … supply modules: installation 40 At a Glance Aim of this Chapter This Chapter deals with the installation of TSX PSY … power supply modules. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Installation/mounting TSX PSY … supply modules . 348 Rules for connecting TSX PSY supply modules 349 Connecting alternating current power supply modules 352 Connecting direct current power supply modules from a floating 24 or 48 VDC direct current network 354 Connecting direct current power supply modules from an alternating current network 356 Sensor and pre-actuator power supply servo control 362 Definition of protection devices at the start of a line 365 347 TSX PSY … supply modules: installation Installation/mounting TSX PSY … supply modules . Mounting The mounting of the TSX PSY… power supply module is identical to the mounting of processor modules and, in general terms, the same as the mounting of other modules (see How to mount processor modules, p. 161). Installation This table describes the principles of installing power supply modules: Type of supply module Description Standard format: TSX PSY 2600/1610 installed in the first slot in each TSX RKY rack and occupy the PS position. Double format: TSX PSY 3610/5500/ 5520/8500 installed in the first two slots in each TSX RKY rack and occupy the PS and 00 positions. Illustration Note: Each supply module is provided with a locating device that only allows the module to be installed in the slot designated above. Note: the TSX PSY 8500 supply module does not provide 24VR voltage. Because of this, a rack fitted with this supply module will not be able to accommodate some modules, such as relay output and weighing modules 348 35011052.06 07/2008 TSX PSY … supply modules: installation Rules for connecting TSX PSY supply modules General points The TSX PSY ••• power supply modules on each rack are equipped with a nonremovable terminal block, provided with a cover, which is used to connect the power supply, the alarm relay, the protection ground and, for alternating current supplies, the supply of the 24 VDC sensors. This screw terminal block is equipped with captive clamp screws which can connect a maximum of 2 wires with a cross-sectional area of 1.5 mm 2 (14 AWG) with wire end ferrules, or one wire with a cross-sectional area of 2.5 mm 2 (12 AWG) (maximum tightening torque on screw terminal: 0.8 N.m (0.6 lb-ft)). The wires come out vertically towards the bottom. These wires can be kept in place with a cable-clip. 35011052.06 07/2008 349 TSX PSY … supply modules: installation Illustration This diagram shows the screw terminal block: Supply 24V sensors Alarm relay Alarm relay Network ~ 110-220V 24V network (1) Protection ground PE Protection ground PE Direct current supply TSX PSY 1610/3610/5520 Alternating current supply TSX PSY 2600/5500/8500 (1) 24...48VAC for the TSX PSY 5520 supply module. CAUTION IMPROPER VOLTAGE SELECTION For the power supply modules TSX PSY 5500/8500, position the voltage selector according to the voltage power used (110 or 220 VAC). Failure to follow these instructions can result in injury or equipment damage. Provide a protection device and switchgear upstream of the PLC station. When selecting protection devices, the user should take into account the signaling currents which are defined in the characteristics tables for each supply module. 350 35011052.06 07/2008 TSX PSY … supply modules: installation Note: As direct current supply modules TSX PSY 1610/2610/5520 have a strong signaling current, it is not advisable to use them on direct current networks which protect flood-back current limits. When a power supply module is connected to a direct current network, it is mandatory to limit the length of the supply cable in order to help preventing transmission loss. z TSX PSY 1610 supply module: z length limited to 30 meters (60 meters there and back) with copper wires and a 2.5 mm2 (12 AWG) cross-section, z length limited to 20 meters (40 meters there and back) with copper wires and a 1.5 mm2 (14 AWG) cross-section. z TSX PSY 3610 and TSX PSY 5520 supply modules: z length limited to 15 meters (30 meters there and back) with copper wires and a 2.5 mm2 (12 AWG) cross-section, z length limited to 10 meters (20 meters there and back) with copper wires and a 1.5 mm2 (14 AWG) cross-section. WARNING DIRECT CURRENT POWER SUPPLY GROUNDING CONSIDERATIONS The 0 V and physical ground are linked internally in the PLCs, in the network cabling accessories, and in some control consoles. For applications which use a "floating" installation, measures need to be taken with connections. These depend on the method used for installation. In these cases, it is mandatory to use insulated direct current power supplies. Please contact us when you are defining the electrical installation. Failure to follow these instructions can result in death, serious injury, or equipment damage. 35011052.06 07/2008 351 TSX PSY … supply modules: installation Connecting alternating current power supply modules Connecting a single-rack PLC station Illustration: Alternating network 100-240 V Supply control Pre-actuators Sensor supply for sensors on the rack (2) TSX PSY ..00 Q: general section switch, KM: circuit contactor-breaker, (1) insulating connector bar for finding grounding faults (2) available current: 0.6 A with a TSX PSY 2600 (see TSX PSY 2600 power supply module, p. 391) power supply module, z 0.8 A with a TSX PSY 5500 (see TSX PSY 5500 power supply module, p. 393) power supply module, z 1.6 A with a TSX PSY 8500 (see TSX PSY 8500 power supply module, p. 395) power supply module, z Note: Protective fuses: alternating current power supply modules TSX PSY 2600/5500/8500 are fitted during manufacture with a protective fuse. This fuse, in series with the L input, is located inside the module and cannot be accessed. 352 35011052.06 07/2008 TSX PSY … supply modules: installation Connecting a PLC station made up of several racks Illustration: Alternating network 100-240 V Supply control pre-actuators Sensor supply for sensors on the rack (2) TSX PSY ..00 Supply control pre-actuators Sensor supply for sensors on the rack (2) TSX PSY ..00 Note: If there are several PLC stations supplied by the same network, the principles of connection are identical. Q: general section switch, KM: circuit contactor-breaker, (1) insulating connector bar for finding grounding faults (2) available current: z 0.6 A with a TSX PSY 2600 (see TSX PSY 2600 power supply module, p. 391) power supply module, z 0.8 A with a TSX PSY 5500 (see TSX PSY 5500 power supply module, p. 393) power supply module, z 1.6 A with a TSX PSY 8500 (see TSX PSY 8500 power supply module, p. 395) power supply module, Note: Protective fuses: alternating current power supply modules TSX PSY 2600/5500/8500 are fitted during manufacture with a protective fuse. This fuse, in series with the L input, is located inside the module and cannot be accessed. 35011052.06 07/2008 353 TSX PSY … supply modules: installation Connecting direct current power supply modules from a floating 24 or 48 VDC direct current network Illustration Diagram showing the principle: Pre-actuator supply control Rack 0 TSX PSY 5520 Alternating network low voltage Battery charger Pre-actuator supply control Rack x Battery TSX PSY 5520 Insulation tester 24 VDC floating network for supplying the sensors, actuators and discrete input/output modules 354 35011052.06 07/2008 TSX PSY … supply modules: installation WARNING GROUNDING CONSIDERATIONS FOR FLOATING MOUNTING OR MARINE APPLICATIONS In the case of floating mounting (not linked to ground) used for specific applications and in particular in Marine Applications, an insulated TSX PSY 5520 (24/48 VDC) supply module must be selected. Failure to follow these instructions can result in death, serious injury, or equipment damage. Note: A device can continually measure the level of insulation of the 24 VDC (or 48 VDC) in relation to the ground, and can give an alert when the level of insulation is abnormally low. The input/output modules in the Premium range are insulated. 35011052.06 07/2008 355 TSX PSY … supply modules: installation Connecting direct current power supply modules from an alternating current network Non-insulated power supply modules TSX PSY 1610/3610 Connecting a single-rack PLC station with a ground-referenced network: Alternating network 100-240 V Supply control pre-actuators TSX PSY ..10 Supply for sensors/ pre-actuators Q: General section switch, KM: Circuit contactor-breaker, (1): External shunt provided with the power supply module, (2): Insulating connector bar for finding grounding faults. In this case, it is necessary to switch off the supply in order to disconnect the network from the ground, (3): Optional use of a process power supply module (see Process and AS-i supply, p. 403), (4): Protective fuse, (4 A, with time-delay) only necessary with the TSX PSY 3610 power supply module. The TSX PSY 1610 power supply module is fitted during manufacture with a protective fuse located under the module and in series on the 24V input (3.5 A, 5x20 time-delay fuse). 356 35011052.06 07/2008 TSX PSY … supply modules: installation Connecting a multi-rack PLC station with a ground-referenced network: Alternating network 100-240 V Supply control pre-actuators TSX PSY ..10 Supply sensors/ pre-actuators Supply control pre-actuators TSX PSY ..10 Q: General section switch, KM: Circuit contactor-breaker, (1): External shunt provided with the power supply module, (2): Insulating connector bar for finding grounding faults. In this case, it is necessary to switch off the supply in order to disconnect the network from the ground, (3): Optional use of a process power supply module, (4): Protective fuse, (4 A, with time-delay) only necessary with the TSX PSY 3610 power supply module. 35011052.06 07/2008 357 TSX PSY … supply modules: installation The TSX PSY 1610 power supply module is fitted during manufacture with a protective fuse located under the module and in series on the 24V input (3.5 A, 5x20 time-delay fuse). Note: If there are several PLC stations supplied by the same network, the principles of connection are identical. 358 35011052.06 07/2008 TSX PSY … supply modules: installation TSX PSY 5520 isolated power supply module Connecting a single-rack PLC station with a ground-referenced network: Alternating network 100-240 V Supply control pre-actuators TSX PSY 5520 Supply for sensors/ pre-actuators Q: General section switch, KM: Circuit contactor-breaker, (1): Insulating connector bar for finding grounding faults, (2): Optional use of a process power supply. Note: Protective fuse: the TSX PSY 5520 power supply modules are fitted during manufacture with a protective fuse. This fuse, in series with the 24/48V input, is located inside the module and cannot be accessed. 35011052.06 07/2008 359 TSX PSY … supply modules: installation Connecting a multi-rack PLC station with a ground-referenced network: Alternating network 100-240 V Supply control pre-actuators TSX PSY 5520 Supply for sensors/ pre-actuators Supply control pre-actuators TSX PSY 5520 Q: General section switch, KM: Circuit contactor-breaker, (1): Insulating connector bar for finding grounding faults, (2): Optional use of a process power supply. 360 35011052.06 07/2008 TSX PSY … supply modules: installation Note: Protective fuse: the TSX PSY 5520 power supply modules are fitted during manufacture with a protective fuse. This fuse, in series with the 24/48V input, is located inside the module and cannot be accessed. Note: If there are several PLC stations supplied by the same network, the principles of connection are identical. 35011052.06 07/2008 361 TSX PSY … supply modules: installation Sensor and pre-actuator power supply servo control How to set up servo control It is recommended that servo control of the different power supplies is set up in the following sequence: Step Safety standards Action 1 Switch on the power supply to the PLC and the inputs (sensors), using the contactor KM (see diagram ("Connecting DC power supply modules from an AC network", Premium and Atrium using Unity Pro, Processors, racks and power supply modules, Implementation Manual)). 2 If the PLC is in RUN mode and running on AUTO, switch on the output power supply (pre-actuators), using the contactor KA. This is controlled by the alarm relay contact in each power supply. Before restarting the installation following a stop (caused by a power outage or an emergency stop), safety standards require authorization to be given by the operator. The MANU/AUTO switch makes it possible to force outputs from a terminal, when the PLC is in STOP mode. 362 35011052.06 07/2008 TSX PSY … supply modules: installation Example 1 PLC station supplied by alternating current: Emergency stop Supply pre-actuators Run Auto Man. alarm relay contact KA: contact controlled by alarm relay from supply module in AUTO run mode. 35011052.06 07/2008 alarm relay contact (1) (1) When the PLC station is composed of several racks: set all the "alarm relay" contacts in series (RAL0, RAL1, RAL2, etc.). 363 TSX PSY … supply modules: installation Example 2 PLC station supplied by direct current: Supply sensors Emergency stop Supply pre-actuators Run Auto Man. alarm relay contact KA: contact controlled by alarm relay from supply module in AUTO run mode. 364 alarm relay contact (1) (1) When the PLC station is composed of several racks: set all the "alarm relay" contacts in series (RAL0, RAL1, RAL2, etc.). 35011052.06 07/2008 TSX PSY … supply modules: installation Definition of protection devices at the start of a line Introduction You are advised to mount a protection device, such as circuit breaker or fuse, at the start of the line on the supply network. The following information can be used to define the minimum amperage rating of the circuit breaker or fuse for a given power supply module. Selecting a line circuit breaker To select the amperage of the circuit breaker, the following three characteristics, which are given for each supply module, should be taken into account. the nominal input current: I rms, signaling current: I, z the It. z z The minimum amperage for the circuit breaker should be selected as follows: amperage of circuit breaker IN > the supply I rms, max. circuit breaker I > the supply signal I, z circuit breaker It at point A on the curve > the supplyIt. z z Illustration: characteristics provided by the circuit breaker manufacturer. Thermal zone Magnetic zone 35011052.06 07/2008 365 TSX PSY … supply modules: installation Selecting the line fuse When selecting the amperage rating of the line fuse, the two following characteristics, which are given for each power supply, should be taken into account: z z the nominal input current: I rms, I2t. The minimum amperage rating for the fuse is selected as follows: fuse caliber IN > 3 x the supply I rms, 2 2 z I t of the fuse > 3 x I t of the power supply. z Reminder of the characteristics of I rms, signal I, It and I2t for each power supply module TSX module I rms I signal(1) It I2 t PSY 2600 PSY 5500 PSY 8500 PSY 1610 PSY 3610 PSY 5520 at 24VDC - - - 1.5A 2.7A 3A at 48VDC - - - - - 1.5A at 100VAC 0.5A 1.7A 1.4A - - - at 24VAC 0.3A 0.5A 0.5A - - - at 24VDC - - - 100A 150A 15A at 48VDC - - - - - 15A at 100VAC 37A 38A 30A - - - at 24VAC 75A 38A 60A - - - at 24VDC - - - 0.2As 0.5As 7As at 48VDC - - - - - 6As at 100VAC 0.034As 0.11As 0.15As - - - at 24VAC 0.067As 0.11As 0.15As - - - at 24VDC - - - 12.5A2s 20A2s 50A2s at 48VDC - - - - - 55A2s at 100VAC 0.63A2s 4A2s 15A2s - - - at 24VAC 2.6A2s 2A2s 8A2s - - - (1) Values at initial power-up and at 25°C. 366 35011052.06 07/2008 TSX PSY … supply modules: diagnostics 41 At a Glance Aim of this Chapter This Chapter deals with the diagnostics of TSX PSY … supply modules . What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Display on TSX PSY supply modules 368 Back-up battery on TSX PSY ... power supply modules 370 Loss of power to rack other than rack 0 372 What happens after pressing the RESET button on a power supply module 373 367 TSX PSY … supply modules: diagnostics Display on TSX PSY supply modules Introduction Each supply module has a display panel containing: three LEDs (OK, BAT, 24V) for the alternating current supply modules TSX PSY 2600/5500/8500, z two LEDs (OK, BAT) for the direct current supply modules TSX PSY 1610/3610/ 5520. z Description The following table describes the various LEDs and their functions: Display LED Description OK LED (green) z on when operating normally, z off when the output voltage is below the thresholds. BAT LED (red) z off when operating normally, z on if battery is missing, flat, the wrong way round or the wrong type. 24V LED (green) z on when operating, z off if the sensor 24V voltage delivered by the supply is no longer present. RESET push-button Pressing this button activates a sequence of service signals identical to: z a power outage, when pressed, z powering up, when released. The application takes these actions (pressing and releasing) to mean a warm restart ("FAST Task Cycle Time", Premium and Atrium using Unity Pro, Processors, racks and power supply modules, Implementation Manual). 368 35011052.06 07/2008 TSX PSY … supply modules: diagnostics Sensor supply The alternating current supply modules TSX PSY 2600/5500/8500 have a built-in power supply which delivers a voltage of 24VDC for supplying the sensors. This sensor power supply can be accessed via the module’s screw connection terminal block. CAUTION Parallelization This supply module cannot be set in parallel with an external supply module. Failure to follow these instructions can result in injury or equipment damage. Note: The "24 VDC sensor supply module" output for the TSX PSY 8500 module is a VLSV-(very low safety voltage) type This ensures the user’s safety. 35011052.06 07/2008 369 TSX PSY … supply modules: diagnostics Back-up battery on TSX PSY ... power supply modules At a Glance Each power supply module has a slot for the installation of a battery which supplies the internal RAM memory of the processors in order to save the data when the PLC is switched off. This battery is delivered in the same packaging as the power supply module. When inserting it, you must respect the polarities. Note: If a Atrium processor which can be integrated into a PC is being used, the back-up battery is built into the processor and its characteristics are the same as those described below. 370 35011052.06 07/2008 TSX PSY … supply modules: diagnostics Data on the backup battery Battery characteristics: thyonile lithium chloride battery, 3.6V/0.8 Ah, 1/2AA size. Spare part product reference: TSX PLP 01. Period for which data is stored: the data storage time depends on two factors: the percentage of time for which the PLC is switched off and as a result the battery is being used, z the ambient temperature when the PLC is switched off. z Table of the ambient temperatures when switched off: Ambient temperature when inoperative ≤ 30°C 40°C 50°C 60°C Backup time PLC off for 12 hours per day 5 years 3 years 2 years 1 year PLC off for 1 hour per day 5 years 5 years 4.5 years 4 years Monitoring the battery status: when the power is on, it monitors the status of the battery. If the battery is less than nominal, the user is informed visually by the BAT (red) LED which lights up. If this happens, the battery must be changed immediately. The %S68 system bit gives the status of the backup battery (0 = battery OK). Changing the battery: the battery can be changed when the power supply module is on, or immediately after switching it off. In the latter case, the time for intervention is limited. The backup time depends on the ambient temperature. Assuming that the processor was switched on previously, the typical backup time varies in the following way. 35011052.06 07/2008 Ambient temperature when switching off 20°C 30°C 40°C 50°C Backup time 2h 45mn 20mn 8mn 371 TSX PSY … supply modules: diagnostics Loss of power to rack other than rack 0 General All the channels on this rack are seen as in error by the processor, but the other racks are not affected. The values of the inputs in error are no longer updated in the application memory and are reset to zero in a discrete input module, unless they have been forced, when they are maintained at the forcing value. Limit of outage period If the outage period is less than 10 ms for alternating current power supplies or less than 1 ms direct current power supplies, the outage is not detected by the program, which will run as normal. 372 35011052.06 07/2008 TSX PSY … supply modules: diagnostics What happens after pressing the RESET button on a power supply module General The power supply module of each rack has a RESET button on its front panel, which when pressed triggers an initialization sequence of the modules on the rack it is supplying. When this action takes place in a power supply module in the rack supporting the TSX P57/TSX H57 processor (rack 0), it causes a warm restart. Special case with the PCI 57 processor 35011052.06 07/2008 In this case, the processor is not physically present on the rack at address 0, so pressing the RESET button on the rack power supply module does not cause the application to warm restart, nevertheless the modules present on the rack are reinitialized. 373 TSX PSY … supply modules: diagnostics 374 35011052.06 07/2008 TSX PSY … supply modules : auxiliary functions 42 At a Glance Aim of this Chapter This Chapter deals with the auxiliary functions of TSX PSY … supply modules . What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Alarm relay on TSX PSY supply modules 376 Characteristics of the alarm relay contact 379 375 TSX PSY … supply modules : auxiliary functions Alarm relay on TSX PSY supply modules Introduction The alarm relay located in each supply module has a potential free contact, which can be accessed on the module’s screw connection terminal block. Illustration: Connection terminal block 376 Ral 35011052.06 07/2008 TSX PSY … supply modules : auxiliary functions Alarm relay of the module situated on the rack supporting the processor (rack 0) When operating normally, with the PLC in RUN mode, the alarm relay is activated and its contact is closed (state 1). Whenever the application is stopped, even partially, when a "blocking" error appears, when there are incorrect output voltages or power disappears, the relay falls back and its associated contact opens (state 0). Illustration: PLC in RUN mode PLC in STOP mode or reporting a fault condition Alarm relay Operation alarm relay rack 0 appearance of a PLC blocking error or incorrect voltages CAUTION SUPPLY MODULE ALARM NOT FUNCTIONAL WITH PCX 57 PROCESSOR When a PCX 57 processor, which can be integrated into a PC, is being used, the supply module alarm relay is not managed and is therefore always open. Failure to follow these instructions can result in injury or equipment damage. If this function is absolutely imperative for the proper operation of the installation, the alarm relay of the power supply module can be replaced by the use of an alarm relay output on the bus X or the FIPIO bus. In order to achieve this, this output should be: a relay output, configured with fallback to 0 (default configuration), z initialized at state 1 when the application program starts executing. z z When configured in this way, the relay output will behave in the same way as the alarm relay controlled by a TSX P57 processor. 35011052.06 07/2008 377 TSX PSY … supply modules : auxiliary functions Alarm relay for modules on the other racks (1 to 7) Once the module has been switched on and if the output voltages are correct, the alarm relay is activated and the contact is closed (state 1). If the power disappears, or if the output voltages are incorrect, the relay falls back (state 0). These modes of operation allow these contacts to be used in fail-safe external circuits, as, for example, the automatic control of pre-actuator supplies, or the transmission of information. 378 35011052.06 07/2008 TSX PSY … supply modules : auxiliary functions Characteristics of the alarm relay contact Characteristics Relay alarm contact. Voltage limit when in use Alternating current 19..0.264 V Direct current (possible up to 34V for 1hr in every 24hrs) 10...30 V Thermal current 3A Alternating current load Resistive load AC 12 Voltage ~24V ~48V Power 50VAC (5) 50VAC (6) 110VAC (6) 220VAC (6) 110VAC (4) 220VAC (4) Inductive AC14 and AC15 Voltage ~24V ~48V Power 24VAC (4) 10VAC (10) 10VAC (11) 10VAC (11) 24VAC (8) 50VAC (7) 50VAC (9) 110VAC (2) 110VAC (6) 220VAC (1) Resistive DC12 Voltage 24V (direct) Power 24 W (6) 40 W (3) Voltage 24V (direct) Power 10 W (8) 24 W (6) Minimum switchable load 1mA/5V Direct current load Inductive load DC13 (L/R=60ms) Response time Activation < 10 ms Deactivation < 10 ms ~110V ~110V ~220V ~220V Type of contact Normally open Built-in protection Against overloading and short circuits None, a fast-blow fuse must be fitted Against inductive over-voltage in ~ None, compulsory installation – in parallel to the terminals of each pre-actuator - of a RC circuit or MOV (ZNO) peak limiter, appropriate to the voltage in use Against direct current inductive over-voltage None, a discharge diode must be fitted to the terminals of each pre-actuator. Insulation (test voltage) Contact/ground 2000 V rms-50/60Hz-1mn (on modules TSX PSY 2600/5500/1610/ 3610/5520) 3000 V rms-50/60Hz-1mn (on module TSX PSY 8500) Resistance of insulation > 10 MΩ under 500 VDC (1) 0.1 x 76 operations 35011052.06 07/2008 (7) 1.5 x 106 operations 379 TSX PSY … supply modules : auxiliary functions (2) 0.15 x 86 operations (8) 2 x 106 operations (3) 0.3 x 96 operations (9) 3 x 106 operations (4) 0.5 x 106 operations (10) 5 x 106 operations (5) 0.7 x 106 operations (11) 10 x 106 operations (6) 1 x 106 operations 380 35011052.06 07/2008 TSX PSY power supply modules: breakdown of power consumption and power 43 At a Glance Aim of this Chapter The aim of this Chapter is to provide a breakdown of power consumption and power for the selection of the power supply module. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Breakdown of power consumption for selection of the power supply module 382 Processor consumption breakdown 384 I/O module consumption breakdown 385 Consumption breakdown of analog/counting/movement control modules 387 Consumption breakdown of communication modules 388 Consumption breakdown (other modules) 390 381 TSX PSY power supply modules: breakdown of power consumption and power Breakdown of power consumption for selection of the power supply module General points The power needed to supply a rack depends on the type of modules installed on it. It is therefore necessary to perform a consumption report in order to define the supply module to be mounted on the rack (standard or double format module). Reminder of the outputs available with each power supply module Summary table: Standard format Double format TSX PSY 1610 TSX PSY 2600 TSX PSY 3610 TSX PSY 5520 TSX PSY 5500 TSX PSY 8500 Total output (all outputs included)(1) (4b) 30 W (30 W) 26W (30 W) 50 W (55) W 50 W (55 W) 50 W (55 W) 77W at 60°C 85W at 55°C, 100W with a TSX FAN Power available on 5 VDC output (1 b) 15 W 25 W 35 W 35 W 35 W 75 W Power available on 24 VR output (2 b) 15 W 15 W 19 W 19 W 19 W not supplied Power available on 24VDC output (sensors supply on the front panel terminal block) (3 b) not supplied 12 W not supplied not supplied 19 W 38 W (1) The values in brackets correspond to the maximum values which can be supported for 1 minute every 10 minutes. These values should not be taken into account when calculating the breakdown of power consumption. WARNING POWER CONSUMPTION LIMITS When the power consumption needs are established, the total power consumed on each output (5 VDC, 24 VR and 24 VS) must not exceed the total output of the module. Failure to follow these instructions can result in death, serious injury, or equipment damage. 382 35011052.06 07/2008 TSX PSY power supply modules: breakdown of power consumption Note: The TSX PSY 8500 supply module does not have a 24 VR output for supplying some modules at 24VDC. Therefore, the following provisions and preparations must be made for all racks which have this type of power supply: z the relay output modules TSX DSY 08R . / 16R. and the weighing module TSX ISP Y 100 cannot be installed on these racks, z the TSX ASY 800 analog output modules should be configured using an external power supply (maximum of 3 modules per rack). Breakdown of power Table of power breakdown: Rack number: 1 Power required at 5VDC output: .........x10-3Ax5V =................W 2 Power required at 24VR output: .........x10-3Ax24V =................W 3 Power required at 24VS output: .........x10-3Ax24V =................W 4 Total power required: =................W WARNING CALCULATED POWER CONSUMPTION VS. CAPACITY The calculated power consumption from above must not exceed the power of the supply modules in the table below. z power required on each output – available power on each output: 1-1a, 2-2a, 33a. z sum of the power required on each output – total power available: 4-4a. Failure to follow these instructions can result in death, serious injury, or equipment damage. 35011052.06 07/2008 383 TSX PSY power supply modules: breakdown of power consumption and power Processor consumption breakdown Table 1 This table shows the typical consumption of each module and can be used to calculate the consumption per rack and on each output depending on the modules installed: Rack number: Module type Product references No. Consumption in mA (typical value) (1) At 5VDC Module Processor + PCMCIA memory card TSX P57 103 440 TSX P57 153 530 TSX P57 203 750 TSX P57 2623 1110 TSX P57 253/353LA 820 TSX P57 2823 1180 TSX P57 303/303A 1000 TSX P57 3623/3623A 1360 TSX P57 353/353A 1060 TSX P57 453/453A 1080 TSX P57 4823/4823A 1440 At 24VR Total Module At 24VS (2) Total Module Total Total (1) Module consumption is given for 100% of inputs or outputs in state 1. (2) If using a 24V (direct) external sensor supply, the consumption on this output should not be taken into account when selecting the power supply for the rack. Note: If the CPU is intended to replace an ATRIUM module in your PLC configuration, make sure that the surplus electrical consumption on the rack which is caused by this modification does not lead to the replacement of your power supply module by a more powerful module. 384 35011052.06 07/2008 TSX PSY power supply modules: breakdown of power consumption I/O module consumption breakdown Table 2 This table shows the typical consumption of each module and can be used to calculate the consumption per rack and on each output depending on the modules installed: Rack number: Module type Product references No. Consumption in mA (typical value) (1) At 5VDC Module At 24VR Total Module At 24VS (2) Total Module Total Carried forward Discrete input TOR outputs 35011052.06 07/2008 TSX DEY 08D2 55 TSX DEY 16A2 80 TSX DEY 16A3 80 TSX DEY 16A4 80 80 TSX DEY 16A5 80 TSX DEY 16D2 80 135 TSX DEY 16D3 80 135 TSX DEY 16FK 250 75 TSX DEY 32D2K 135 160 TSX DEY 32D3K 140 275 TSX DEY 64D2K 155 TSX DSY 08R4D 55 315 80 TSX DSY 08R5 55 70 TSX DSY 08R5A 55 80 TSX DSY 08S5 125 TSX DSY 08T2 55 TSX DSY 08T22 55 TSX DSY 08T31 55 TSX DSY 16R5 80 TSX DSY 16S4 220 TSX DSY 16S5 220 TSX DSY 16T2 80 TSX DSY 16T3 80 TSX DSY 32T2K 140 TSX DSY 64T2K 155 135 385 TSX PSY power supply modules: breakdown of power consumption and power Rack number: Discrete Inputs/ Outputs TSX DMY 28FK 300 75 TSX DMY 28RFK 300 75 Total (1) Module consumption is given for 100% of inputs or outputs in state 1. (2) If using a 24V (direct) external sensor supply, the consumption on this output should not be taken into account when selecting the power supply for the rack. 386 35011052.06 07/2008 TSX PSY power supply modules: breakdown of power consumption Consumption breakdown of analog/counting/movement control modules Table 3 This table shows the typical consumption of each module and can be used to calculate the consumption per rack and on each output depending on the modules installed: Rack number: Module type Product references No. Consumption in mA (typical value) (1) At 5VDC Module At 24VR Total Module At 24VS (2) Total Module Total Carried forward Analog Counting Axis control Step by step control TSX AEY 414 660 TSX AEY 420 500 TSX AEY 800 270 TSX AEY 810 475 TSX AEY 1600 270 TSX AEY 1614 300 TSX AEY 410 990 TSX AEY 800 (3) 200 TSX CTY 2A 280 30 TSX CTY 2C 850 15 TSX CTY 4A 330 36 TSX CAY 21 1100 15 TSX CAY 22 1100 15 TSX CAY 33 1500 30 TSX CAY 41 1500 30 TSX CAY 42 1500 30 300 TSX CSY 84 1800 TSX CFY 11 510 50 TSX CFY 21 650 100 Grand total (1) Module consumption is given for 100% of inputs or outputs in state 1. (2) If using a 24V (direct) external sensor supply, the consumption on this output should not be taken into account when selecting the power supply for the rack. (3) If using a 24VR (direct) external power supply, the consumption of 300mA on the internal 24VR should not be taken into account when selecting the rack power supply. 35011052.06 07/2008 387 TSX PSY power supply modules: breakdown of power consumption and power Consumption breakdown of communication modules Table 4 This table shows the typical consumption of each module and can be used to calculate the consumption per rack and on each output depending on the modules installed: Rack number: Module type Product references No. Consumption in mA (typical value) (1) At 5VDC Module At 24VR Total Module At 24VS (2) Total Module Total Carried forward Communication TSX ETY 110 (3) (4) 800 TSX ETY 120 (3) (4) 800 TSX ETY 210 (3) (4) 800 1200 1200 1200 TSX ETY 4102/5102 360 TSX IBY 100 500 TSX PBY 100 400 TSX SAY 100 110 TSX SAY 1000 100 TSX SCY 21601 350 TSX SCP 111 140 TSX SCP 112 120 TSX SCP 114 150 TSX FPP 10 330 TSX FPP 200 330 TSX JNP 112 120 TSX JNP 114 150 TSX MBP 100 220 TSX MDM 10 195 Grand total (1) Module consumption is given for 100% of inputs or outputs in state 1, 388 35011052.06 07/2008 TSX PSY power supply modules: breakdown of power consumption (2) if using a 24V (direct) external sensor power supply, the consumption on this output should not be taken into account when selecting the power supply for the rack, (3) without remote power feed (RJ45), (4) with remote power feed (AUI). 35011052.06 07/2008 389 TSX PSY power supply modules: breakdown of power consumption and power Consumption breakdown (other modules) Table 5 This table shows the typical consumption of each module and can be used to calculate the consumption per rack and on each output depending on the modules installed: Rack number: Module type Product references No. Consumption in mA (typical value) (1) At 5VDC Module At 24VR Total Module At 24VS (2) Total Module Total Carried forward Weighing TSX ISPY 100/101 150 Emergency stop backup TSX PAY 262 150 TSX PAY 282 150 Remote bus X TSX REY 200 500 Other (devices TSX P ACC01 without their own T FTX 117 (adjust) power supply which can be connected to the terminal port) 145 150 310 Grand total (1) Module consumption is given for 100% of inputs or outputs in state 1, (2) If using a 24V (direct) external sensor power supply, the consumption on this output should not be taken into account when selecting the power supply for the rack. 390 35011052.06 07/2008 TSX PSY 2600 power supply module 44 Characteristics of the TSX PSY 2600 power supply module Characteristics The TSX PSY 2600 module is a single format alternating current power supply module. Reference TSX PSY 2600 Primary Nominal voltage (V) ~ 100...240 Voltage limits (V) ~ 85...264 Nominal and limit frequencies 50-60/47-63Hz Apparent power 50 VA Nominal current consumption: Irms ≤ 0.5A to 100V ≤ 0.3A to 240V Initial power-up at 25°C (1) I signal ≤ 37A to 100V ≤ 75A to 240V I 2t on locking 0.63A2s to 100V It on locking 0.034 As at 100V 0.067 As at 240V Accepted length of micro-power outages Integrated phase protection 35011052.06 07/2008 2.6A2s to 240V ≤10ms via internal, non-accessible fuse 391 TSX PSY 2600 power supply module Reference TSX PSY 2600 Secondary Total output 5VDC output 24VR output (24V relay) (2) 24VS output (24V sensor) Protection of output from 26W Nominal voltage: 5.1V Nominal current 5A Power (typical) 25W Nominal voltage: 24VDC Nominal current 0.6A Power (typical) 15W Nominal voltage: 24VDC Nominal current 0.5A Power (typical) 12W overloading/short circuits/over-voltages Power dissipation 10W Auxiliary functions Alarm relay yes (1 contact closed, free from potential on terminal block) Display yes, via LED on front panel Back-up battery yes (status monitored via LED on front panel of module) Conformity to IEC 1131-2 the norms Insulation Dielectric resistance (50/60Hz1mn) Primary/secondary 2000 Vrms Primary/ground 2000 Vrms 24VDC output/ground Resistance of insulation Primary/secondary ≥ 100 MΩ Primary/ground ≥ 100 MΩ (1) These values should be taken into account when starting up several devices at the same time, or for dimensioning the protection systems. (2) 24V direct current output for supplying relays of "relay output" modules. 392 35011052.06 07/2008 TSX PSY 5500 power supply module 45 Characteristics of the TSX PSY 5500 power supply module Characteristics The TSX PSY 5500 module is a double format alternating current power supply module. Reference Primary Nominal voltage (V) ~ 100..120/ 200..240 Voltage limits (V) ~ 85..140/190..264 Nominal and limit frequencies 50-60/47-63Hz Apparent power 150 VA Nominal current consumption: Irms ≤ 1.7A to 100V ≤ 0.5A to 240V Initial power-up at 25°C (1) I signal ≤ 38A to 100V ≤ 38A to 240V I 2t on locking 4A2s to 100V It on locking 0.11 As at 100V 0.11 As at 240V Accepted length of micro-power outages Integrated phase protection 35011052.06 07/2008 2A2s to 240V ≤10ms via internal, non-accessible fuse 393 TSX PSY 5500 power supply module Reference Secondary Total output 5VDC output 24VR output (24V relay) (2) 24VS output (24V sensor) Protection of output from 50W Nominal voltage: 5.1V Nominal current 7A Power (typical) 35W Nominal voltage: 24VCC Nominal current 0.8A Power (typical) 19W Nominal voltage: 24VCC Nominal current 0.8A Power (typical) 19W overloading/short circuits/over-voltages Power dissipation 20W Auxiliary functions Alarm relay yes (1 contact closed, free from potential on terminal block) Display yes, via LED on front panel Back-up battery yes (status monitored via LED on front panel of module) Conformity to IEC 1131-2 the norms Insulation Dielectric resistance (50/60Hz1mn) Primary/secondary 2000 Vrms Primary/ground 2000 Vrms 24VDC output/ground Resistance of insulation Primary/secondary ≥ 100 MΩ Primary/ground ≥ 100 MΩ (1) These values should be taken into account when starting up several devices at the same time, or for dimensioning the protection systems. (2) 24V direct current output for supplying relays of "relay output" modules. 394 35011052.06 07/2008 TSX PSY 8500 power supply module 46 Characteristics of the TSX PSY 8500 power supply module Characteristics The TSX PSY 8500 module is a double format alternating current power supply module. Reference Primary Nominal voltage (V) ~ 100..120/ 200..240 Voltage limits (V) ~ 85..140/170..264 Nominal and limit frequencies 50-60/47-63Hz Apparent power 150 VA Nominal current consumption: Irms ≤ 1.4A to 100V ≤ 0.5A to 240V Initial power-up at 25°C (1) I signal ≤ 30A to 100V ≤ 60A to 240V I 2t on locking 15A2s to 100V 8A2s to 240V It on locking 0.15 As at 100V 0.15 As at 240V Accepted length of micro-power outages ≤10ms Integrated phase protection via internal, non-accessible fuse 35011052.06 07/2008 395 TSX PSY 8500 power supply module Reference Secondary Total output 5VDC output 77/85/100W (2) Nominal voltage: 5.1V Nominal current 15A Power (typical) 75W 24VR output (24V relay) (3) Nominal voltage: 24VS output (24V sensor) Protection of output from not supplied Nominal current not supplied Power (typical) not supplied Nominal voltage: 24VDC Nominal current 1.6A Power (typical) 38W overloading/short circuits/over-voltages Power dissipation 20W Auxiliary functions Alarm relay yes (1 contact closed, free from potential on terminal block) Display yes, via LED on front panel Back-up battery yes (status monitored via LED on front panel of module) Conformity to the norms IEC 1131-2 Insulation Dielectric resistance (50/ 60Hz-1mn) Resistance of insulation Primary/secondary 3000 Vrms Primary/ground 3000 Vrms 24VDC output/ ground 500 Vrms Primary/secondary ≥ 100 MΩ Primary/ground ≥ 100 MΩ (3) 24V direct current output for supplying relays of "relay output" modules. 396 35011052.06 07/2008 TSX PSY 1610 power supply module 47 Characteristics of the TSX PSY 1610 power supply module Characteristics The TSX PSY 1610 module is a single format non-isolated direct current power supply module. Reference Primary TSX PSY 1610 Nominal voltage (not isolated) 24 VDC Voltage limits (including ripple) (1) (possible up to 34V for 1hr in every 24hrs) 19.2 to 30 VDC Nominal input current: Irms at 24VDC ≤1.5 A Initial power-up at 25°C (2) I signal ≤ 100A at 24V DC I2t on locking 12.5 A2s It on locking 0.2 As Accepted length of micro-power outages Integrated input protection 35011052.06 07/2008 ≤1ms via 5x20 time delay fuse, 3.5A 397 TSX PSY 1610 power supply module Reference TSX PSY 1610 Secondary Total output (typical) 5VDC output 30 W Nominal voltage: 5V Nominal current 3A Power (typical) 15W 24VR output (24VDC relay) (3) Nominal voltage: Built-in output protection against (4) U network – 0.6V Nominal current 0.6 A Power (typical) 15 W Overloading yes Short circuits yes Over-voltage Power dissipation yes 10W Auxiliary functions Alarm relay yes (1 contact closed, free from potential on terminal block) Display yes, via LED on front panel Back-up battery yes (status monitored via LED on front panel of module) Conformity to the norms IEC1131-2 (1) With the supply of "relay output" modules, the limit range is reduced to 21.6V26.4V. (2) These values should be taken into account when starting up several devices at the same time, and for dimensioning the protection systems. (3) 24V direct current output for supplying relays of "relay output" modules. (4) The 24VR output voltage, which cannot be accessed by the user, is protected by a fuse which is located under the module (5x20, 4A, Medium type). 398 35011052.06 07/2008 TSX PSY 3610 power supply module 48 Characteristics of the TSX PSY 3610 power supply module Characteristics The TSX PSY 3610 module is a double format non-insulated direct current supply module. Reference Primary Nominal voltage 24 VDC Voltage limits (including ripple) (1) (possible up to 34V for 1hr in every 24hrs) 19.2 to 30 VDC Nominal input current: Irms at 24VDC ≤2.7 A Initial power-up at 25°C (2) I signal ≤ 150A at 24V DC I2t on locking 20 A2s It on locking 0.5 As Accepted length of micro-power outages Integrated input protection 35011052.06 07/2008 ≤1ms no 399 TSX PSY 3610 power supply module Reference Secondary Total output (typical) 5VDC output 24VR output (24V relay) (3) Built-in output protection against (4) 50 W Nominal voltage: 5.1V Nominal current 7A Power (typical) 35W Nominal voltage: U network – 0.6V Nominal current 0.8 A Power (typical) 19 W Overloading yes Short circuits yes Over-voltage yes Power dissipation 15W Auxiliary functions Alarm relay yes (1 contact closed, free from potential on terminal block) Display yes, via LED on front panel Back-up battery yes (status monitored via LED on front panel of module) Conformity to the norms IEC1131-2 (1) With the supply of "relay output" modules, the limit range is reduced to 21.6V26.4V. (2) These values should be taken into account when starting up several devices at the same time, and for dimensioning the protection systems. (3) 24V direct current output for supplying relays of "relay output" modules. (4) The 24VR output voltage, which cannot be accessed by the user, is protected by a fuse which is located under the module (5x20, 4A, Medium type). 400 35011052.06 07/2008 TSX PSY 5520 power supply module 49 Characteristics of the TSX PSY 5520 power supply module Characteristics The TSX PSY 5520 module is a double format insulated direct current power supply module. Reference Primary Nominal voltage 24..0.48 VDC Voltage limits (including ripple) 19.2 to 60VDC Nominal input current: Irms ≤ 3 A at 24V DC ≤ 1.5A at 48V DC Initial power-up at 25°C (1) I signal ≤ 15A at 24V DC ≤ 15 A at 48V DC I 2t on locking 50 A2s at 24VDC It on locking 7 As at 24VDC 6 As at 48VDC Accepted length of micro-power outages Built-in protection of + input 35011052.06 07/2008 55 A2s at 48VDC ≤1ms by internal, non-accessible fuse module 401 TSX PSY 5520 power supply module Reference Secondary Total output (typical) 5VDC output 24VR output (24VDC relay) (2) 50 W Nominal voltage: 5.1V Nominal current 7A Power (typical) 35W Nominal voltage: 24 V Nominal current 0.8 A Power (typical) 19 W Built-in output protection against Overloading yes Short circuits yes Over-voltage Power dissipation yes 20W Auxiliary functions Alarm relay yes (1 contact closed, free from potential on terminal block) Display yes, via LED on front panel Back-up battery yes (status monitored via LED on front panel of module) Conformity to the norms Insulation Dielectric resistance IEC1131-2 primary/secondary primary/ground Resistance of insulation primary/secondary primary/ground 2000 Vrms-50/ 60Hz-1mn 2000 Vrms-50/ 60Hz-1mn ≥ 10 MΩ ≥ 10 MΩ (1) These values should be taken into account when starting up several devices at the same time, and for dimensioning the protection systems. (2) 24VDC output for supplying the relays of the "relay output" modules. 402 35011052.06 07/2008 Process and AS-i supply VI At a Glance Aim of this Part This Part describes Process and AS-i supply and their installation. What's in this Part? This part contains the following chapters: 35011052.06 07/2008 Chapter Chapter Name Page 50 Process and AS-i supply: introduction 405 51 Process and AS-i suppliers: installation 419 52 Process supply modules: connections 431 53 Connecting AS-i supply modules 439 54 Process and AS-i supply module characteristics 449 403 Process and AS-i supply 404 35011052.06 07/2008 Process and AS-i supply: introduction 50 At a Glance Aim of this Chapter This Chapter introduces Process and AS-i supply. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page General introduction to Process and AS-i power supply modules 406 Physical description of TBX SUP 10 supply block 407 Physical description of the TSX SUP 1011 supply module 408 Physical description of TSX 1021/1051 supply modules 409 Physical description of the TSX SUP A02 supply module 411 Description of TSX SUP 1101/A05 supply blocks 412 Physical description of the support board 413 Process supply: auxiliary functions 415 AS-i supply module: dedicated features 417 405 Process and AS-i supply: introduction General introduction to Process and AS-i power supply modules General A wide range of power supply units and modules is offered to meet your needs in the best possible way: TBX SUP 10 and TSX SUP 1..1 process power supply units and modules, designed to supply 24 VDC to a PLC system periphery, and driven by PLCs (TSX Micro and Premium). This periphery being composed of sensors, preactuators, encoders, operator dialog terminals, regulators, LEDs, push-buttons, pneumatic actuators, etc. . This 24 V power supply can be delivered using a 100/240 V, 50/60 Hz AC network. The power supply modules TBX SUP 10 and TSX SUP 1011 can also be connected to a 125 VDC network. z The AS-i power supply units and modules TSX SUP A02 and A05 designed to supply 30 VDC to the components connected to an AS-i field bus. This power supply is distributed over the same wires as those used for data exchange. z The attachment mode for these products has been specially designed to respond to the specific mounting distances and specifications of TSX Micro and TSX Premium PLCs, and TBX products. All the products are mounted: z z 406 on a Telequick AM1-PA mounting plate, on a central DIN rail AM1-DP200/DE200, except for the high-power power supply blocks TSX SUP 1101 and TSX SUP A05. 35011052.06 07/2008 Process and AS-i supply: introduction Physical description of TBX SUP 10 supply block Illustration Diagram and numbers: 1 2 3 4 Number table The following table shows the numbers and their corresponding descriptions from the diagram above: Numbers 35011052.06 07/2008 Description 1 LED showing power-up of module. 2 Screw terminal block for supply voltage wiring. 3 Identification label for the wire terminals. 4 Wings for fixing the module. 407 Process and AS-i supply: introduction Physical description of the TSX SUP 1011 supply module Illustration Diagram and numbers: Number table The following table shows the numbers and their corresponding descriptions from the diagram above: Numbers Description 1 2 Support board for fixing the supply module directly onto the AM1-DE200 / DP200 DIN mounting track or the AM1-PA Telequick perforated board. Display block with: z a 24 V LED (green): lit if the established internal and output voltages are correct, z a LSH LED (orange) "power optimization mode": lit if the power supply is running in parallelization mode with power optimization. 3 4 Flap for protecting the terminal block. Screw terminal block for connection: z to the AC/DC supply network, z to 24 VDC output. 5 Hole for the cable-tightening clip to go through. 6 "NOR/LSH" switch placed at the back of the module to control the power optimization system. z NOR position: normal operation without power optimization (default position), z LSH position: operation with power optimization with supply running in parallel. Note: Access to the switch requires the module to be removed from the support board. 408 35011052.06 07/2008 Process and AS-i supply: introduction Physical description of TSX 1021/1051 supply modules Illustration Diagram and numbers: 1 2 3 4 5 6 7 35011052.06 07/2008 409 Process and AS-i supply: introduction Number table The following table shows the numbers and their corresponding descriptions from the diagram above: Numbers 1 2 Description Support board for fixing the supply module directly onto the AM1-DE200 / DP200 DIN mounting track or the AM1-PA Telequick perforated board. Display block with: z a 24 V LED (green): lit if the internal and output voltages are correct, z a LSH LED (orange) only on TSX SUP 1021 "power optimization mode": lit if the power supply is running in parallelization mode with power optimization. 3 4 Flap for protecting the terminal block. Screw terminal block for connection: z to the AC/DC supply network, z to 24 VDC output. 5 Hole for the cable-tightening clip to go through. 6 110/220 V voltage selector. On delivery, the selector is set at 220. 7 "NOR/LSH" switch placed at the back of the module to control the power optimization system. This switch is only present on the TSX SUP 1021 module. z NOR position: normal operation without power optimization (default position), z LSH position: operation with power optimization with supply running in parallel. Note: Access to the switch requires the module to be removed from the support board. 410 35011052.06 07/2008 Process and AS-i supply: introduction Physical description of the TSX SUP A02 supply module Illustration Diagram and numbers: Number table The following table shows the numbers and their corresponding descriptions from the diagram above: Numbers 35011052.06 07/2008 Description 1 Support board for mounting the supply module directly onto the AM1-DE200 / DP200 DIN mounting rail or the AM1-PA Telequick board. 2 Display block with: z an AS-i LED (green): lit if the internal and output voltages are correct, 3 Flap for protecting the terminal block. 4 Screw terminal block for connection: z to an alternating supply network, z from AS-i 30 VDC output. 5 Hole for the cable-tightening clip to go through. 6 110/220 V voltage selector. On delivery, the selector is set at 220. 411 Process and AS-i supply: introduction Description of TSX SUP 1101/A05 supply blocks Illustration Diagram and numbers: Number table The following table shows the numbers and their corresponding descriptions from the diagram above: Numbers 412 Description 1 Display block with an ON LED (orange): lit if power supply is running. 2 Display block with: z a 24 V LED (green): lit if 24 VDC output voltage is present and correct, z an AS-i LED (green): lit if the AS-i 30 VDC output voltage is present and correct. This LED is only present on the TSX SUP A05. 3 Flap for protecting terminal blocks. 4 Screw terminal block for connection to alternating supply network. 5 Screw terminal block for connecting AS-i 24 VDC and 30 VDC output voltage to TSX SUP A05. 6 Holes for the cable-tightening clip to go through. 7 Four mounting holes for M6 screws. 35011052.06 07/2008 Process and AS-i supply: introduction Physical description of the support board Introduction Each TSX SUP 10.1 and TSX SUP A02 supply module is delivered mounted on a support board. This is used to fix the supply module: the DIN AM1-DE200 or AM1DP200 profile, or to a Telequick AM1-PA perforated mounting plate. Each support board can take: either a TSX SUP 1021, TSX SUP 1051 or TSX SUP A02 module, or one or two TSX SUP 1011 modules. Illustration 35011052.06 07/2008 Diagram and numbers: 413 Process and AS-i supply: introduction Information Table The following table shows the numbers and their corresponding descriptions from the diagram above: Number Description 1 Three 5.5 mm diameter holes for mounting the board onto a panel or an AM1PA perforated board with a mounting distance of 140 mm (mounting distance for TSX 37 PLCs). 2 Four 6.5 mm diameter holes for mounting the board onto a panel or an AM1PA perforated board with a mounting distance of 88.9 mm (mounting distance for TSX 57 PLCs). 3 Two M4 holes for mounting TSX SUP 1011/1021/1051/A02 supply module(s). 4 Windows designed to ink pins situated at the bottom and at the back of the module. Note: • each of these supply modules can also be mounted on a TSX RKY••• rack in place of another module, except in position PS. This must only be used by a TSX PSY••• supply module for supplying rack modules. • the following operations require the module to be removed from the support board: - positioning the "NOR/LSH" switch onto "LSH", - mounting the board onto a panel or AM1-PA perforated board, - mounting the module onto a TSX RKY••• rack. 414 35011052.06 07/2008 Process and AS-i supply: introduction Process supply: auxiliary functions Parallelization mode with power optimization The aim of parallelization is to use two modules with the same product reference in order to provide an output current which is greater than the maximum allowed by a single supply. The total current is the sum of the currents provided by all the supplies put together. Power optimization is a system within the supply which is designed to distribute currents equally between parallel supplies. The resulting advantage is that the life of products is significantly extended, linked with distributed power consumption. Dedicated supply features: TSX SUP 1011/1021 Power optimization mode is obtained by positioning the NOR/LSH supply switch at the rear of the modules onto LSH. To access the switch, the support board must be removed. When the orange LED (LSH) is lit, the mode is in operation. The current provided by two parallel supplies is limited to: z 2A with 2 TSX SUP 1011 suppliers, z 4A with 2 TSX SUP 1021 suppliers. Using this mode means output voltage can vary slightly: 24V + or - 5% instead 24 V + or - 3% in normal mode. When sharing loads, the power imbalance can reach a maximum of 25%. A specific connection (see Connection of TSX SUP 1011/1021 power supplies, p. 432) is required for these types of modules. TSX SUP 1051/1101 Power optimization mode does not require a switch on these supply supply modules. A specific connection must be made for the TSX SUP 1051 (see Connection of TSX SUP 1051 power supplies, p. 434) module and the TSX SUP 1101 (see Connection of TSX SUP 1101 power supplies, p. 436) module. The maximum current provided by two parallel supplies is limited to: z 10A with 2 TSX SUP 1051 suppliers, z 20A with 2 TSX SUP 1101 suppliers. Using this mode will lead to no loss of output voltage: When sharing loads, the power imbalance can reach a maximum of 15%. 35011052.06 07/2008 415 Process and AS-i supply: introduction Redundancy on TSX SUP 1011/ 1021 power supplies Principle: To provide the currents required for the application, even in the event of loss of one of the power supplies. To do this, the two suppliers are run in parallel by setting up the necessary connections (see Connection of TSX SUP 1011/1021 power supplies, p. 432). The suppliers are configured in power optimization mode. Example: provide 1A with redundancy from 2 TSX SUP 1011 suppliers. Fuse Discrete inputs 1 and 2 on the PLC indicate the loss of one or other of the power supplies. Load Note: TSX SUP 1051 and 1101 suppliers are not equipped with a serial diode, which is required for the redundancy function. 416 35011052.06 07/2008 Process and AS-i supply: introduction AS-i supply module: dedicated features General The simultaneous transmission of information and power down the same cable means that data transmission needs to be filtered in relation to supply. This is why AS-i supply module has a built-in decoupling filter which supports the maximum direct current provided by the power supply. A standardized impedance is introduced into the power supply in relation to the frequency of information transmission. 35011052.06 07/2008 417 Process and AS-i supply: introduction 418 35011052.06 07/2008 Process and AS-i suppliers: installation 51 At a Glance Aim of this Chapter This Chapter deals with the installation of Process and AS-i supply modules. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page TBX SUP 10 dimensions/mounting/connections 420 Dimensions/mounting Process and AS-i supply modules 422 TSX SUP 1101/A05 supply block dimensions/mounting 427 Summary of mounting methods 429 419 Process and AS-i suppliers: installation TBX SUP 10 dimensions/mounting/connections Dimensions/ mounting Illustration: The TBX SUP 10 supply block must be mounted in an upright position to allow for the best possible natural air convection within the block. It can be mounted on a panel, an AM1-PA Telequick perforated board or AM1DE200 / DP200 mounting rail. 420 35011052.06 07/2008 Process and AS-i suppliers: installation Connections Illustration: (1) External protection fuse on phase: 1A time delay 250V if single supply block. Note: Primary: if the module is supplied with a 100/240V alternating current, the phase and the neutral wire must be taken into account when wiring. On the other hand, if the module is supplied with a 125 V direct current, polarities do not need to be taken into account. Secondary: the terminal, with 0V potential, must be connected to the ground as soon as the supply module starts to provide output. DANGER HAZARDOUS VOLTAGE The module ground terminal must be connected to the protective ground with a green/yellow wire. Failure to follow these instructions will result in death or serious injury. 35011052.06 07/2008 421 Process and AS-i suppliers: installation Dimensions/mounting Process and AS-i supply modules At a Glance Each power supply module is delivered with a support which allows it to be mounted directly on a DIN (AM1-D••••) mounting rail or TELEQUICK (AM1-PA) mounting plate. The support is able to receive: z z 1 or 2 TSX SUP 1011 power supply modules, 1 TSX SUP 1021/1051/A02 power supply module. Note: When using the TELEQUICK mounting plate, it is necessary to remove the module. 1 module TSX SUP 1011 422 2 modules TSX SUP 1011 1 module TSX SUP 1021/ 1051/A02 35011052.06 07/2008 Process and AS-i suppliers: installation Dimensions The illustration below shows the dimensions of the modules and support and the overall dimensions for each type of mounting system. SUP 1011 SUP 1021/ 1051/A02 Mounting support Dimensions in millimeters TSX SUP 1011/1021/1051/A02 power supply modules can be mounted in different ways: Mounting on an AM1-DE200 or AM1-DP200 mounting rail or on an AM1-PA board Each supply module is delivered fixed to a support which can be mounted in this way. 35011052.06 07/2008 423 Process and AS-i suppliers: installation Mounting on an AM1-D mounting rail (1) 147.2mm (AM1-DE200) 139.7mm (AM1-DP200) Carry out the following steps: Step 424 Action 1 Remove the module from its support. 2 Mount the support, using 3 M6x25 screws, onto the AM1-D••• mounting rails equipped with AF1-CF56 1/4 turn sliding nuts. 3 Mount the module on its support. 35011052.06 07/2008 Process and AS-i suppliers: installation Mounting on an AM1-PA board (2) 136.7 mm (AM1-PA) Carry out the following steps: Step Removing the module Action 1 Remove the module from its support. 2 Mount the support onto the AM1-PA board. 3 Mount the module on its support. Carry out the following steps: Step Action 1 Loosen the screw on the upper part of the module in order to separate it from the support. 2 Rotate the module in order to free the lower pins from the support. Illustration: Support Support 35011052.06 07/2008 425 Process and AS-i suppliers: installation Mounting on an AM1-ED••• mounting rail Mounting on a TSX RKY••• rack Carry out the following steps: Step Action 1 Remove the module from its support. 2 Mount the support, using 3 M6x25 screws, onto the AM1-ED••• mounting rails equipped with AF1-CF56 1/4 turn sliding nuts. 3 Mount the module on its support. TSX SUP 1011/1021/1051/A02 power supply modules can be mounted in any position on the TSX RKY•• rack, except for the PS position reserved for the power supply module of the rack. In this case, the support is not used and must be removed. The support delivered with the supply module is not used and must be removed; the module is in this case mounted in the same way as the other modules (e.g.: processor (see How to mount processor modules, p. 161). Note: The power supply module of the TSX PSY••• rack must be in the PS position in order to supply power to the modules in the rack. 426 35011052.06 07/2008 Process and AS-i suppliers: installation TSX SUP 1101/A05 supply block dimensions/mounting Introduction TSX SUP 1101 and TSX SUP A05 supply blocks can be mounted on a panel, an AM1-PA board, or DIN rail. Mounting on a panel Screw-hole layout (dimensions in millimeters): 4 mounting holes (1) (1) The diameter of the mounting holes must be sufficient to take M6 screws. Mounting on an AM1-PA Telequick mounting grid 35011052.06 07/2008 Fix the supply block with 4 M6 x 25 screws + washers and AF1-EA6 clips nuts (dimensions in millimeters): 427 Process and AS-i suppliers: installation Mounting on 35 mm wide DIN mounting rail 428 Fix the supply block using 4 M6 x 25 screws + washers and AF1-CF6 1/4 turn sliding nuts (dimensions in millimeters): 35011052.06 07/2008 Process and AS-i suppliers: installation Summary of mounting methods Summary table of mounting methods The following table lists a summary of the different methods available for mounting Process and AS-i supply modules: Supply module product reference TBX SUP 10 TSX SUP 1011 TSX SUP 1021 TSX SUP 1051 TSX SUP 1101 TSX SUP A02 TSX SUP A05 AM1-PA Telequick board X X X X X X X AM1-DE200/DP200 central DIN rail X X X X AM1-ED DIN rail with 88.9 mm spacing (TSX 57 PLC) X X X TSX 57 rack TSX RKY•• X X X 35011052.06 07/2008 X X X X X 429 Process and AS-i suppliers: installation 430 35011052.06 07/2008 Process supply modules: connections 52 At a Glance Aim of this Chapter This Chapter deals with the connection of Process supply modules. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Connection of TSX SUP 1011/1021 power supplies 432 Connection of TSX SUP 1051 power supplies 434 Connection of TSX SUP 1101 power supplies 436 431 Process and AS-i supply modules: connections Connection of TSX SUP 1011/1021 power supplies Illustration Connection diagram: Parallelization Normal connection Module 1 Module 2 Fu=External fuse on phase (Fu): 250 V 4 A time delay. (1) 100...240 VAC on TSX SUP 1011 100...120/200..240 VAC on TSX SUP 1021 (2) 125 VDC, only on TSX SUP 1011. 432 35011052.06 07/2008 Process and AS-i supply modules: connections Connection rules Primary:if the module is supplied with a 100/240 VAC power supply, it is necessary to observe wiring requirements for the phase and neutral when connecting the module. However, if the module is powered by a 125 VDC supply, it is not necessary to respect the polarities. z an operating voltage ≥ 600 VAC with a cross-section of 1.5 mm2 (14 AWG) for connection to the mains, DANGER HAZARDOUS VOLTAGE The ground terminal of the module must be connected to the protective earth using a green/yellow wire. Failure to follow these instructions will result in death or serious injury. The power supply terminal is protected by a flap which allows access to the wiring terminals. The wires come vertically out of the power supply at its base. These wires can be kept in place with a cable-clip. Secondary: to comply with isolation requirements (EN 60950) for a 24 V SELV isolated voltage, the following wiring is used: z 35011052.06 07/2008 an operating voltage ≥ 300 VAC with a cross-section of 2.5 mm2 (12 AWG) for the 24 V outputs and the ground. 433 Process and AS-i supply modules: connections Connection of TSX SUP 1051 power supplies Illustration Connection diagram: Normal connection Parallelization Module 1 Fu=External safety fuse on phase (Fu): 250 V 4 A time delay 434 Module 2 35011052.06 07/2008 Process and AS-i supply modules: connections Connection rules Primary: observe the rules concerning phase and neutral when wiring. z an operating voltage ≥ 600 VAC with a cross-section of 1.5 mm2 (14 AWG) for connection to the mains, DANGER HAZARDOUS VOLTAGE The ground terminal of the module must be connected to the protective earth using a green/yellow wire. Failure to follow these instructions will result in death or serious injury. The power supply terminal is protected by a flap which allows access to the wiring terminals. The wires come vertically out of the power supply at its base. These wires can be kept in place with a cable-clip. Secondary: to comply with isolation requirements (EN 60950) for a 24 V SELV isolated voltage, the following wiring is used: z 35011052.06 07/2008 an operating voltage ≥ 300 VAC with a cross-section of 2.5 mm2 (12 AWG) for the 24 V outputs and the ground. 435 Process and AS-i supply modules: connections Connection of TSX SUP 1101 power supplies Illustration 1 Normal connection diagram: output terminal input terminal AC network connection 200..240 V 436 AC network connection 100..120 V 24 VDC output connection. 35011052.06 07/2008 Process and AS-i supply modules: connections Illustration 2 Parallel connection diagram (parallelization): input terminals output terminals Module 1 Module 2 (1) Connection for a 100...120 VAC power supply. (2) External fuse on phase (Fu): 250 V 6.3 A time delay. 35011052.06 07/2008 437 Process and AS-i supply modules: connections Connection rules Primary: Observe the rules concerning phase and neutral when wiring. z an operating voltage ≥ 600 VAC with a cross-section of 1.5 mm2 (14 AWG) or 2.5 mm2 (12 AWG) for connection to the mains, DANGER HAZARDOUS VOLTAGE The ground terminal of the module must be connected to the protective earth using a green/yellow wire. Failure to follow these instructions will result in death or serious injury. The power supply terminal is protected by a flap which allows access to the wiring terminals. The wires come vertically out of the power supply at its base. These wires can be kept in place with a cable-clip. Secondary: To comply with isolation requirements (EN 60950) for a 24 V SELV isolated voltage, the following wiring is used: an operating voltage ≥ 300 VAC with a cross-section of 2.5 mm2 (12 AWG) for the 24 V outputs and the ground. z Wire the two 24 V terminals in parallel, or distribute the load over the two 24 V outputs when the total current to be supplied is greater than 5 A. z 438 35011052.06 07/2008 Connecting AS-i supply modules 53 At a Glance Aim of this Chapter This Chapter deals with the connection of AS-i supply modules. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Connection of TSX SUP A02 power supply modules 440 Connecting TSX SUP A05 supply modules 442 General precautions 446 439 Connecting AS-i supply modules Connection of TSX SUP A02 power supply modules Illustration Connection diagram: (1) Shielded AS-i cable screen if environment is disturbed. Fu=External fuse on phase (Fu): 250 V 4 A time delay. Connection synoptic The TSX SUP A02 power supply module is designed to supply the AS-i bus, and the connected slaves (30 VDC/2.4 A). AS-i Master 440 35011052.06 07/2008 Connecting AS-i supply modules Connection rules Primary: observe the rules concerning phase and neutral when wiring. DANGER HAZARDOUS VOLTAGE The ground terminal of the module must be connected to the protective earth using a green/yellow wire. Failure to follow these instructions will result in death or serious injury. The power supply terminal is protected by a flap which allows access to the wiring terminals. The wires come vertically out of the power supply at its base. These wires can be kept in place with a cable-clip. To comply with isolation requirements (EN 60950) for a 24 V SELV isolated voltage, the following wiring is used: an operating voltage ≥ 600 VAC with a cross-section of 1.5 mm2 (14 AWG) for connection to the mains, 2 z an operating voltage ≥ 300 VAC with a cross-section of 2.5 mm (12 AWG) for the 24 V outputs and the ground. z It is necessary to use a shielded cable for the AS-i bus only in cases where the installation is subject to very high levels of disturbance in terms of EMC (Electro Magnetic Compatibility). 35011052.06 07/2008 441 Connecting AS-i supply modules Connecting TSX SUP A05 supply modules Illustration Connection diagram: Input terminal Output terminal (1) (3) Connection to alternating network 200...240 V Connection to an alternating network 100...120 V Direct output connection 24 V and 30 V AS-i (1) Connection if supply is from 100...120 V alternating current network. (2) External protection fuse on phase (Fu): 6.3 A time delay 250 V. (3) Shielded AS-i cable screen in case of disrupted surroundings. 442 35011052.06 07/2008 Connecting AS-i supply modules Connection overview The TSX SUP A05 supply module is designed to supply the AS-i bus, including the slaves which are connected to it (30 V/5 A output). It also has an auxiliary supply (24 VDC/7 A) for sensors/actuators which consume large amounts of current. For this, a black AS-i ribbon cable is used. Principle diagram: AS-i master 35011052.06 07/2008 443 Connecting AS-i supply modules Rules of connection Primary: observe the rules concerning phase and neutral when wiring. z an operating voltage ≥ 600 VAC with a cross-section of 1.5 mm2 (14 AWG) or 2.5 mm2 (12 AWG) for connection to the mains, DANGER HAZARDOUS VOLTAGE The module ground terminal must be connected to the protective ground with a green/yellow wire. Failure to follow these instructions will result in death or serious injury. The "AC power supply network" and "24 V and 30 VDC output" AS-i terminals are protected by a flap allowing access to the wiring terminals. The wires come vertically out of the power supply at its base. These wires can be kept in place with a cableclip. Secondary: to comply with isolation requirements (EN 60950) for a 24 V SELV isolated voltage, the following wiring is used: an operating voltage ≥ 300 VAC with a cross-section of 2.5 mm2 (12 AWG) for the 24 V outputs and the ground, z connect the two 24 V terminals in parallel, or distribute the load over the two 24 V outputs when the total current to be provided is greater than 5 A. z Using a shielded cable for the AS-i bus is only necessary if the installation is overly disrupted in terms of EMC (Electro Magnetic Compatibility). Given the large current that this supply module provides, its position on the bus is very important. If the supply module is placed at one of the ends of the bus, it will provide a nominal current (e.g. 5 A) for the whole bus. The voltage drop at the end of the bus is therefore proportional to the 5 A. If it is positioned in the middle of the bus, the voltage drop at the ends is proportional to only 2.5 A, assuming that the consumption for both sections of the bus is the same. 444 35011052.06 07/2008 Connecting AS-i supply modules Supply AS-i 2.5 A 2.5 A If there is no slave which consumes large amounts of power, it would be better to place the supply module in the middle of the installation. Conversely, if the installation has one or several large power consumers, it would be wise to place the supply module close to them. Note: Where there are large power consumer actuators (contactor, solenoid coils etc.) the TSX SUP A05 supply module can provide the auxiliary 24 VDC, insulated from the AS-i line. 35011052.06 07/2008 445 Connecting AS-i supply modules General precautions Introduction While installing the yellow AS-i cable, it is essential to place it in a cable track which is separate from the power cables. It is also advisable to place it flat and not twisted. This will help make the two AS-i cable wires as symmetrical as possible. Installing the AS-i cable on a surface connected to the electric potential of the machine (for example, the housing) complies with the requirements of the EMC (Electro Magnetic Compatibility) directive. The end of the cable, or the ends in the case of a bus with a star-formation , must be protected either: z z by connecting it (them) to a T-derivation, by not allowing them to come out of their last connection point. Important It is important to distribute power effectively on the AS-i bus, so that each device on the bus is supplied with sufficient voltage to enable it to operate properly. To do this, certain rules must be followed. Rule 1 Select the capacity of the supply module adapted to the total consumption of the ASi segment. Available capacities are 2.4 A (TSX SUP A02) and 5 A (TSX SUP A05). A capacity of 2.4 A is generally sufficient based on an average consumption of 65mA per slave for a segment made up of a maximum of 31 slaves. 446 35011052.06 07/2008 Connecting AS-i supply modules Rule 2 To minimize the effect of voltage drops and reduce the cost of the cable, you must determine the best position of the supply module on the bus, as well as the minimum size of cable appropriate for distributing power. The voltage drop between the master and the last slave on the bus must not exceed 3 V. For that purpose, the table below gives the essential points for selecting the cross-sectional measurement of the AS-i cable. Table of characteristics: Cross-section 0.75 mm2 (28 AWG) 1.5 mm2 (14 AWG) 2.5 mm2 measurement of AS-i cable (12 AWG) Linear resistance 52 milli Ohms/meter 27 milli Ohms/ meter 16 milli Ohms/ meter Voltage drop for 1 A over 100 meters (328 feet) 5.2 V 2.7 V 1.6 V The cable which can be used for most applications is the cable with a cross-section of 1.5 mm2 (14 AWG). This is the standard AS-i bus model (the cable is offered in the SCHNEIDER catalog). Smaller cables can be used when sensors consume very little power. Note: The maximum length of all the segments making up the AS-i bus without a relay is 100 meters (328 feet). The lengths of cables which link a slave to a passive distribution box must be taken into account. 35011052.06 07/2008 447 Connecting AS-i supply modules 448 35011052.06 07/2008 Process and AS-i supply module characteristics 54 At a Glance Aim of this Chapter This Chapter presents the different electrical characteristics of Process and AS-i supply modules in a table. What's in this Chapter? This chapter contains the following topics: 35011052.06 07/2008 Topic Page Electrical characteristics of process supply modules: TBX SUP 10 and TSX SUP 1011 450 Electrical characteristics of process supply modules: TSX SUP 1021/1051/ 1101 452 Electrical characteristics of AS-i supply modules: TSX SUP A02/A05 454 Physical environmental characteristics 457 449 Process and AS-i supply module characteristics Electrical characteristics of process supply modules: TBX SUP 10 and TSX SUP 1011 Table of Characteristics The following table describes the electrical characteristics of supply modules: TBX SUP 10 and TSX SUP 1011: Process supply TBX SUP 10 24V/1A TSX SUP 1011 24V/ 1A Primary Nominal input voltage V alternating 100240 direct 125 alternating 100240 direct 125 Input limit voltage V alternating 90264 direct 88156 alternating 85264 direct 105156 Network frequency Hz 47...63 47...63/360...440 Nominal input current (U=100V) On 0.4 0.4 Maximum call current (1) to 100 V On 3 37 to 240 V On 30 75 Maximum It on trigger (1) to 100 V As 0.03 0.034 to 240 V As 0.07 0.067 to 100 V 2 A s 2 0.63 to 240 V A 2s 2 2.6 Power factor 0.6 0.6 Harmonic (3) 10% (Phi=0°and 180°) 10% (Phi=0°and 180°) 2 Maximum I t on trigger (1) Full load efficiency % >75 >75 Output (2) W 24 26(30) Nominal output current (2) On 1 1.1 Secondary 450 35011052.06 07/2008 Process and AS-i supply module characteristics Process supply TBX SUP 10 24V/1A TSX SUP 1011 24V/ 1A Output voltage/ accuracy at 25°C V 24+/-5% 24+/-3% Residual ripple (peak to peak) Maximum HF noise (peak to peak) mV 240 150 mV 240 240 ms ≤10 in AC ≤1 in DC ≤10 in AC ≤1 in DC continuous automatic reset fallback to 0 and automatic reset after fault has disappeared cuts off at U>36 cuts off at U>36 Parallelization no yes with power optimization Serialization no yes Power dissipation 8 18 Accepted length of micro-power outages (3) Protection against Short circuits and overloads Overvoltages V (1) Values on initial power-up at 25°C. These elements are to be taken into account on start-up for the dimensioning of protection devices. (2) Output power and current for an ambient temperature of 60°C. Input value in ( ) = output in a ventilated cabinet or within a temperature range of 0+40°C. (3) A nominal voltage for a repetition period of 1Hz. 35011052.06 07/2008 451 Process and AS-i supply module characteristics Electrical characteristics of process supply modules: TSX SUP 1021/1051/1101 Table of Characteristics The following table describes the electrical characteristics of supply modules: TSX SUP 1021/1051/1101: Process supply TSX SUP 1021 24V/2A TSX SUP 1051 24V/5A TSX SUP 1101 24V/10A Primary Nominal input voltage V alternating 100..0.120/200..0.240 Input limit voltage V alternating 85...132/170...264 Network frequency Hz 47...63/360...440 Nominal input current (U=100V) On 0.8 Maximum call current (1) Maximum It on trigger (1) 2.4 5 to 100 V On <30 51 75 to 240 V On <30 51 51 to 100 V As 0.06 0.17 0.17 to 240 V As 0.03 0.17 0.17 to 100 V A 2s 4 8.6 8.5 to 240 V 2s 4 8.6 8.5 Power factor 0.6 0.52 0.5 Harmonic 3 10% (ϕ=0° and 180°) Maximum I2t on trigger (1) Full load efficiency A % >75 >80 Secondary Output (2) W 53(60) 120 240 Nominal output current (2) On 2.2 5 10 Residual ripple (peak to peak) mV 150 Maximum HF noise (peak to peak) mV Output voltage (0°C-60°c) V 24+/-3% mV 240 Accepted length of micro-power outages (3) ms <=10 Start-up time on resisting load <1 452 s 24+/-1% 200 35011052.06 07/2008 Process and AS-i supply module characteristics Process supply Protection against TSX SUP 1021 24V/2A TSX SUP 1051 24V/5A Short circuits and overloads Overvoltages V fallback to 0 and automatic reset after fault has disappeared current limit cuts off at U>36 cuts off at U>32 Parallelization yes with power optimization Serialization yes Power dissipation 18 30 TSX SUP 1101 24V/10A 60 (1) Values on initial power-up at 25°C. These elements are to be taken into account on start-up for the dimensioning of protection devices. (2) Output power and current for an ambient temperature of 60°C. Input value in ( ) = output in a ventilated cabinet or within a temperature range of 0+40°C. (3) A nominal voltage for a repetition period of 1Hz. 35011052.06 07/2008 453 Process and AS-i supply module characteristics Electrical characteristics of AS-i supply modules: TSX SUP A02/A05 Table of Characteristics The following table describes the electrical characteristics of supply modules: TSX SUP A02/A05: References TSX SUP A02 30V AS-i / 2.4A TSX SUP A05 24V/7 AS-i & 30V AS-i/5A Primary Nominal input voltage V alternating 100..0.120/ 200..0.240 alternating 100..0.120/200..0.240 Input limit voltage V alternating 85...132/ 170...264 alternating 85...132/170...264 Network frequency Hz 47...63/360...440 47...63/360...440 Nominal input current (U=100V) On 1.3 5 Maximum call current (1) to 100 V On 30 50 to 240 V On 30 50 to 100 V As 0.06 0.17 Maximum It on trigger (1) 2 Maximum I t on trigger (1) to 240 V As 0.03 0.17 to 100 V 2 A s 4 8.5 to 240 V A 2s 4 8.5 0.6 0.51 Power factor Harmonic 3 10% (Phi=0°and 180°) 10% (Phi=0°and 180°) % >75 >80 W 72(84) (2) 230 (3) 30 V AS-i output On 2.4(2.8) (2) 5 (3)(4) 24 V output On - 7 (3)(4) Full load efficiency Secondary Output Peak nominal current 454 35011052.06 07/2008 Process and AS-i supply module characteristics References TSX SUP A02 30V AS-i / 2.4A TSX SUP A05 24V/7 AS-i & 30V AS-i/5A Output voltage Global variation (-10°C to +60°C) V V 30(AS-i) 29.5 to 31.6 24 +/-3% 30(AS-i) 29.5 to 31.6 Ripple (from 10 to 500 kHz) mV 50 200 50 300 Ripple (from 0 to 10 kHz) mV 300 240 Start-up time on resisting load s <2 (where C=15000 micro Farads <2 (where C= 15000 micro Farads) Length of micro power outages (5) ms ≤10 Protection against Short circuits and overloads Overvoltages Power dissipation fallback to 0 and automatic reset after fault has disappeared current limit on each output V cuts off at U>36 cuts off at U>36 W 24 60 (1) Values on initial power-up at 25°C. These elements are to be taken into account on start-up for the dimensioning of protection devices. (2) Output and output current for an ambient temperature of 60°C. Input value () = surge output. (3) Output and output current for a maximum ambient temperature of 55°C, if product index II = 01 (60°C if product index II > 01). (4) distribution of current for each output (see Chart of available currents on 30 V AS-i and 24 V output from the TSX SUP A05 supply block., p. 456). (5) Acceptable period at nominal voltage for a repetition period of 1 Hz. 35011052.06 07/2008 455 Process and AS-i supply module characteristics Chart of available currents on 30 V AS-i and 24 V output from the TSX SUP A05 supply block. 456 The maximum power which can be delivered by the supply block is 230 W. If consumption is 5 A on the 30 V AS-i, possible flow on 24 V output is no greater than 3 A (see chart below). Chart: 35011052.06 07/2008 Process and AS-i supply module characteristics Physical environmental characteristics Table of characteristics The following table describes the electrical characteristics of Process and AS-i supply modules: Process and AS-i supply blocks/ modules TBX SUP 10 Connection to screw terminals 1 terminal per output 1011/1021/1051/A02: 1 output terminal 1101 : 2 terminals/output A05: 2 terminals/output (24 VDC) 1 x 2.5 (12 AWG) 1 terminal/output (30 VDC AS-i) 2 x 1.5 (14 AWG) with adapter or 1 x 2.5 (12 AWG) maximum capacity per terminal mm2 Temperature: Storage Operating °C °C Relative humidity % 5-95 Cooling % By natural convection Reference standard 35011052.06 07/2008 -25 to +70 +5 to +55 - Dielectric strength: Primary/secondary Primary/ground Secondary/ground V eff V eff V eff 50/60 Hz-1 mm 1500 1500 500 Insulation resistance Primary/secondary Primary/ground MΩ MΩ ≥ 100 ≥ 100 TSX SUP 1011/1021 TSX SUP 1051/1101 TSX SUP A02/A05 -25 to +70 0 to +60 (TSX SUP 1011/1021/ 1051/1101 -10 to +60 (TSX SUP A02/A05) (1) Very Low Voltage Safety (EN 60950 and IEC 1131-2) 3500 2200 500 Leakage current I≤=3.5 mA (EN 60950) Electrostatic uploading immunity 6 kV per contact/8 KV in the air (complies with IEC 1000-4-2) Fast electric surge 2 kV (serial mode and common mode on input and output) Electromagnetic field influence 10 V/m (80 MHz to 1 GHz) Rejected electromagnetic disturbances (comply with FCC 15-A et EN 55022 class A Test conditions: nominal U and I, resisting load, cable: 1 meter horizontally, 0.8 meters vertically 457 Process and AS-i supply module characteristics Process and AS-i supply blocks/ modules TBX SUP 10 Shock wave Input: 4 kV MC, 2 kV MS Outputs: 2 kV MF, 0.5 kV MS (complies with IEC 1000-4-5) Vibration (2) 1 mm 3 Hz to 13.2 Hz 1g 57 Hz to 150 Hz (2g TSX SUP A02/A05) (complies with IEC 68-2-6, FC test) Degree of protection IP 20.5 MTBF at 40°C Length of life at 50°C TSX SUP 1011/1021 TSX SUP 1051/1101 TSX SUP A02/A05 IP 20.5, terminal IP 21.5 H 100 000 H 30 000 (at nominal voltage and 80 % of nominal power) (1) -10°C +55°C for TSX SUP A05 supply module with product index II=01. -10°C +60°C for TSX SUP A05 supply module with product index II > 01. (2) complies with IEC 68-2-6, FC test with module or block mounted on a board or panel. 458 35011052.06 07/2008 B AC Index Addressing two racks at the same address, 93 agency approvals, 55 Alarm relay, 376 323 Characteristics of AS-i supply modules, 454 compliance, 55 Configuring the PCX 57 processor address, 302 Configuring the processor’s address, 304 B D A Battery PCMCIA Card, 189 battery for PCMCIA cards lifetime, 193 Blocking errors, 208 Building a PCX 57 PLC station with a TSX RKY rack, 89 Building a TSX P57 PLC station with TSX RKY racks, 86 Bus X extension module diagnostics, 140 installation, 129 Bus X extension modules connections, 138 C Changing the battery on the TSX P57, 182 Changing the PCMCIA Card Battery on the TSX P57, 185 Changing the PCMCIA TSX MRP DS 2048 P Card Battery on the TSX P57, 187 Changing the PCX 57 battery, 320 Changing the PCX 57 PCMCIA card battery, 35011052 06 07/2008 Description of PCX 57 processors, 288 Description of the support board, 413 Description of the TSX SUP A02 supply module, 411 Description of TSX SUP 1101/A05 supply blocks, 412 diagnosing power supplies, 368 diagnostics for CPU modules, 177 Premium, 177 diagnostics for power supplies, 367 Dimensions of PCX 57 processor cards, 291 E Environment characteristics of AS-i supply modules, 457 Event response time, 282 F FAST cycle time, 281 Finding errors using the processor state LEDs, 205 459 Index fusing, 365 G General characteristics of the PCX 57 203 processor, 329 General characteristics of the PCX 57 353 processor, 331 General introduction to PCX 57 processors, 26 General introduction to Process and AS-i power supply modules, 406 General introduction to Process and AS-i TSX SUP and TSX 1021/1051 power supply modules, 29 General introduction to the AS-i bus interface module TSX SAY, 43 General Introduction to the TSX P57, 148 General introduction to the TSX PAY emergency stop monitoring module, 46 General introduction to the TSX REY bus X extension module, 31 General introduction to TSX CFY step by step control modules, 37 General introduction to TSX DEY/DSY/DMY input/output modules, 32 General Introduction to TSX P57 Processors, 24 General introduction to TSX RKY racks, 27 General introduction to TSX SCY/ETY communication, 38 grounding racks, 84 installing CPUs Premium, 99 installing power supplies, 347 installing process power supplies, 431 installing racks, 77 Installing the PCX 57 preliminary operations, 301 Installing the PCX 57 processor, 297 Integrating a PCX 57 into an bus X section, 310 Introduction to PCX 57 processors, 286 Introduction to TSX CAY axis control modules, 35 L Logical installation of the PCX 57 processor on the bus X, 298 M MAST cycle time, 273, 275, 279 Memory Card TSX MRP DS 2048 P, 174 Memory Card TSX MRP F 004M, 174 Memory Cards, 168, 171 memory cards, 157 Module addresses, 94 Module installation on a rack, 96 Mounting/Removing a PCMCIA Card on TSX P57, 164 N Non blocking errors, 206 H O How the PCX 57 behaves after an action on the PC, 326 Overview of a PLC station, 21 Overview of aPLC station, 20 I P Installation/mounting TSX PSY supply modules, 348 Installing a PCX 57 in the PC, 308 installing batteries, 177 PCMCIA cards, 157 PCX 57 card components, 292 performance, 271 460 35011052 06 07/2008 Index Physical Description of TSX P57 Processors, 150 PLC station rack addressing, 91 PLC station topology, extension module, 142 Positioning of line termination, 107 Positioning of the processor module, 158 power consumption, 381 power supply modules, 339 Processing on insertion/extraction of a PCMCIA memory card on a PCX 57 PLC, 314 Processing on Insertion/Extraction of a PCMCIA Memory Card on a Premium PLC, 167 Processor/system errors, 209 processors Premium, 145 R Rack power supply failure, 372 racks accessories, 99 Real-time clock, 153 T topologies racks, 85 TSX CBY..0K bus X extension cable, 100 TSX P 57 103 characteristics, 211 TSX P57 153 characteristics, 213 TSX P57 203 characteristics, 215 TSX P57 253 characteristics, 217 TSX P57 2623 characteristics, 219 TSX P57 2823 characteristics, 223 TSX P57 303 characteristics, 227 TSX P57 303A characteristics, 229 TSX P57 353 characteristics, 233 TSX P57 353A characteristics, 235 TSX P57 353LA characteristics, 239 TSX P57 3623 characteristics, 243 TSX P57 3623A characteristics, 247 TSX P57 453 characteristics, 251 TSX P57 453A characteristics, 253 TSX P57 4823 characteristics, 257 35011052 06 07/2008 TSX P57 4823A characteristics, 261 TSX P57 Electrical Characteristics, 266 TSX SUP 10 dimensions/mounting/ connection, 420 TSXCBY..0K, 99 TSXCBY1000, 99 TSXFAN, 113 TSXH5724M, 145 TSXH5744M, 145 TSXP53204, 145 TSXP57/TSXH57, 145 TSXP570244, 145 TSXP57104, 145 TSXP57154, 145 TSXP571634, 145 TSXP57254, 145 TSXP572634, 145 TSXP57304, 145 TSXP57354, 145 TSXP573634, 145 TSXP57454, 145 TSXP574634, 145 TSXP57554, 145 TSXP575634, 145 TSXP576634, 145 TSXPSY1610, 397 TSXPSY2600, 391 TSXPSY3610, 399 TSXPSY5500, 393 TSXPSY5520, 401 TSXREY200, 125 TSXRKA02, 108 TSXRKYxx, 65 TSXTLYEX, 105 V VAC power systems, 362 VDC power systems, 362 Ventilation module mounting, 118 ventilation modules, 113 Viewing on TSX P57, 178 461 Index W What happens after you press the processor RESET button, 325 X X-Bus extension modules, 125 462 35011052 06 07/2008 ">
/
Descarcă
Doar o reamintire prietenoasă. Poți vizualiza documentul chiar aici. Dar cel mai important, AI-ul nostru l-a citit deja. Poate explica lucruri complexe în termeni simpli, poate răspunde la întrebările tale în orice limbă și te poate ajuta să navighezi rapid chiar și prin cele mai lungi sau mai complicate documente.
Publicitate