Intelligent Digital Pressure Modules

Pressure ranges to 60,000 psi (4,200 bar)

Pressure measurement accuracy of 0.02% FS

Intrinsically Safe (Ex)

Fully temperature compensated accuracy

OVERVIEW ADT158Ex

With advanced microprocessor technology and state-of-the-art silicon pressure sensors, Additel’s 158Ex series Digital

Pressure Modules provide an accurate, reliable, and economic solution for wide range of pressure applications. Our intrinsically safe (Ex) models are up to the task of providing the best possible results, even in hazardous environments.

In order to reach the best performance, every silicon pressure sensor in the module has been specially aged, tested and screened before assembly. Designed as field switchable pressure modules for use with Additel 273Ex and

260Ex handheld devices, the Additel 158Ex is unmatched in performance and reliability. If intrinsic safety is a critical requirement for your workload, we have you covered when you combine our model ADT273Ex or ADT260Ex handheld calibrators with any of our ADT158Ex pressure modules.

GP500

GP600

GP1K

GP1.5K

GP2K

GP3K

GP5K

V15

GP2

GP5

GP10

GP15

GP30

GP50

GP100

GP150

GP300

GP10K

GP15K

GP20K

GP25K

GP30K

GP36K

GP40K

GP50K

GP60K

FEATURES

Gauge pressure measurement accuracy of 0.02% FS

Pressure ranges to 60,000 psi (4,200 bar)

Intrinsically Safe with ADT260EX and ADT273EX

Advanced temperature compensation

ISO 17025 accredited calibration and data included

PRESSURE RANGE

Gauge Pressure [1]

P/N

Pressure Range

(psi) (bar)

500

600

1,000

1,500

2,000

3,000

5,000

10

15

30

50

-15

2

5

100

150

300

10,000

15,000

20,000

25,000

30,000

36,000

40,000

50,000

60,000

35

40

70

100

140

200

350

-1.0

0.16

0.35

0.7

1.0

2.0

3.5

7.0

10

20

700

1,000

1,400

1,600

2,000

2,500

2,800

3,500

4,200

Media

[2]

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G

G

G

G

G

G

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

G , L

Accuracy(%FS)

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.02

0.05

0.05

0.05

0.05

0.05

0.05

0.1

0.1

0.02

0.05

0.05

0.02

0.02

0.02

0.02

0.02

0.02

0.02

Burst

Pressure

2x

1.5x

1.5x

1.5x

1.5x

1.35x

1.2x

1.1x

[1] Sealed gauge pressure for above 1000 psi

[2] G=Gas, L=Liquid

Phone: 714-998-6899 Email: [email protected]

Rev # 20220322

Corporate Headquarters

2900 Saturn St #B

Brea, CA 92821, USA

Salt Lake City Office

1364 West State Rd. Suite 101

Pleasant Grove, UT 84062, USA

SPECIFICATIONS

Compound Pressure

P/N

CP2

CP5

CP10

CP15

CP30

CP50

CP100

CP150

CP300

CP500

CP600

CP1K

CP2K

CP3K

CP5K

CP10K psig

Pressure Range bar.g

±2

±5

±10

±15

-15 to 30

-15 to 50

-15 to 100

-15 to 150

-15 to 300

-15 to 500

-15 to 600

-15 to 1,000

-15 to 2,000

-15 to 3,000

-15 to 5,000

-15 to 10,000

±0.16

±0.35

±0.7

±1.0

-1 to 40

-1 to 70

-1 to 140

-1 to 200

-1 to 350

-1 to 700

-1 to 2.0

-1 to 3.5

-1 to 7.0

-1 to 10

-1 to 20

-1 to 35

Barometric Pressure

P/N

BP

Pressure Range

Low

60 kPa

High

110 kPa

Media

G

Media

G

G

G,L

G,L

G,L

G,L

G

G

G

G

G,L

G,L

G,L

G,L

G,L

G,L

Accuracy

0.05% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

0.02% FS

Accuracy

55 Pa

Burst

Pressure Rating

Over Pressure

3x

3x

3x

3x

3x

3x

3x

3x

3x

3x

3x

3x

3x

3x

3x

2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

1.2x

Burst Pressure

02

Additel 273Ex and 260Ex with ADT158 pressure module installed

Phone: 714-998-6899 Email: [email protected]

Rev # 20220322

Corporate Headquarters

2900 Saturn St #B

Brea, CA 92821, USA

Salt Lake City Office

1364 West State Rd. Suite 101

Pleasant Grove, UT 84062, USA

ORDERING INFORMATION

Model Number

ADT158EX

02 GP300

SPECIFICATIONS

PSI N

Model:

ADT158Ex

Range type:

PSI - range by psi

BAR - range by bar Accuracy:

02 - 0.02% of full scale

05 - 0.05% of full scale

10 - 0.1% of full scale

Pressure range P/N:

See pressure range tables

Pressure port type:

N - 1/4NPT male

N2 - 1/2NPT male

B - 1/4BSP male

B2 - 1/2BSP male

M - M20 X 1.5 male

AF - Autoclave F-250-C female

AM - Autoclave M-250-C male

Accessories included

ISO 17025 accredited Calibration Certificate

Operating temperature

Storage temperature

Relative humidity

Pressure connections

(for external use only)

Enclosure

(for external use only)

Intrinisic Safety

Dimensions (Dia x H)

Weight

Warranty

CPXXX

Standard Accuracy

GPXXX

-10°C to 50°C (14°F to 122°F)

-20°C to 70°C (-4°F to 158°F)

95% RH

1/4NPT, 1/2NPT, 1/4BSP, 1/2BPS, M20x15

SS enclosure

ATEX certified intrinsically safe only with ADT260EX & ADT273EX

33 mm x 123 mm (1.3” x 4.84”)

0.4 kg (0.99 lb)

1 Year

03

Phone: 714-998-6899 Email: [email protected]

Rev # 20220322

Corporate Headquarters

2900 Saturn St #B

Brea, CA 92821, USA

Salt Lake City Office

1364 West State Rd. Suite 101

Pleasant Grove, UT 84062, USA

advertisement

Related manuals

Download PDF

advertisement