Koden KDS-5000BB Operation Manual
Reklama
Reklama
KDS-5000BB Revision History
KDS-5000BB Operation Manual
Doc No: 0093150002
Document Revision History
No. Doc. No.- Rev. No. Revised Date
(Y/M/D)
0 0093150002-00
1 0093150002-01
2 0093150002-02
3 0093150002-03
4
5
6
7
8
9
10
Revised Content
2017/01/27 First edition
2017/04/19 Declaration, Transducer auto down →TD auto down
2019/01/15 Specifications
2020/10/01 Declaration, Cover
Document No. Revised Version Norm
When part of the document needs to be revised, the document has advanced revision number.
The document No. is indicated at the lower right side on the cover and at the left or right side of the footer region of each page.
© 2017-2020 Koden Electronics Co., Ltd. All rights reserved.
No part of this publication may be reproduced, transmitted, translated in any form by any means without the written permission of Koden Electronics Co., Ltd. The technical descriptions contained in this publication are subject to change without notice. Koden assumes no responsibility for any errors, incidentals or consequential damages caused by misinterpretation of the descriptions contained in this publication.
0093150002-03 i
Important Notice KDS-5000BB
Important Notice
• For copy and transcription of this Operation Manual (hereinafter referred to as this manual), permission from Koden is needed. Koden prohibits the un-authorized copy and transcription of this manual.
• If this manual is lost or damaged, consult a dealer of Koden or Koden.
• The specification of the products and the contents in this manual are subject to change without notice.
• The contents displayed on the menu of product may be different from the expression of this manual. The fonts and shapes of the keys and menus in the illustration may differ from the actual ones, and some parts may be omitted.
• Koden is not liable for damages and troubles arisen from misunderstanding of the contents in this manual.
• Koden is not liable for any damages caused by earthquake, lightning, wind and flood damage and fire for which Koden is not responsible, and actions by third parties, other accidents , customer’s unintended error/abuse and the use under other abnormal conditions.
• Koden is not liable for damages of accompaniment (change/loss of memorized content, loss of business profit, stop of business) arisen from use or failure of our products.
• If the stored data are changed or lost, irrespective of causes of troubles and damages,
Koden is not liable for them.
• Koden is not liable for any damages arisen from malfunction caused by combination of software and connected equipment in which Koden is not engaged.
ii 0093150002-03
KDS-5000BB For Your Safe Operation
For Your Safe Operation
Symbol used in this Operation Manual
The following pictograms are used in this manual. The meaning of each symbols shall be well understood and the maintenance and inspection shall be carried out.
Symbol Meaning
Warning
Mark for warning
This mark denotes that there is a risk of death or serious injury when dealt with incorrectly.
Mark for danger of high voltage
This mark denotes that there is a risk of death or serious injury due to electric shock when dealt with incorrectly.
Caution
Mark for caution
This mark denotes that there is a risk of slight injury or damages of devices when dealt with incorrectly.
Mark for prohibition
This mark denotes prohibition of specified conducts. Description of the prohibition is displayed near the mark.
Caution items on equipment
Warning
Warning
Be careful of high voltage inside
High voltage, which may risk your life, is used. This high voltage may remain in the circuit even after the power is switched off. To prevent contact with the high voltage circuits accidentally, a protective cover or the label with this mark is provided on the high voltage circuit. When the inside is to be checked, ensure to switch off the power and to discharge the residual voltage for safety. An engineer authorized by Koden shall carry out the inspection and maintenance works.
Power off in the boat
An accidental power-on during works may result in worker’s electrification. To prevent such accident in advance, ensure that power in the boat and on the equipment are switched off. Furthermore, it is safer to hang a caution tag saying “Under work” near the power switch of equipment.
Be careful of dust
Inhaled dust may cause respiratory affection. At the time of cleaning the inside of equipment, be careful not to inhale dust. Wearing a safety mask is recommended.
0093150002-03 iii
For Your Safe Operation KDS-500BB
Caution
Caution
Caution
Caution on location of installment
The equipment shall not be installed at locations which are excessively damp and suffers from water drops. Otherwise, dew condensation may occur inside the display screen, and corrosion may occur inside the unit box.
Measures against static electricity
Static electricity may be generated from the carpet on the floor in the cabin or clothes made of synthetic fiber, and it may destroy the electronic components on circuit boards. The circuit boards shall be handled with appropriate measures against static electricity.
Caution at installation of Transducer unit
Transducer unit shall be installed at locations where there is no effect by bubble and noise. Bubble and noise may seriously degrade the performance of this equipment.
Cautions on handling
Warning ing
No disassembly or modification of this equipment is allowed. It may lead to failure, firing, smoking or electric shock. In case of failure, please contact Koden’s dealers or Koden.
Warning
In case of smoking or firing, switch off the power in the boat and of this equipment. It may lead to firing, electric shock or damages.
Caution
Be careful of residual high voltage
High voltage may remain in capacitors for several minutes after switching off the power. Before inspection of the inside, please wait at least 5 minutes after switching off or discharge the residual electricity in an appropriate manner. Then, start the work.
The information displayed on this equipment is not intended to use for your navigation. For your navigation, be sure to see the specified materials.
Please use the specified fuses. If un-specified fuses are used, they may cause firing, smoking or damages.
Caution
Be sure to submerge the Transducer unit in water before transmission.
If not, it may be damaged. Caution iv 0093150002-03
CONTENTS
SONAR OPERATION
Chapter 1 Introduction
………………..….….…………… 2
Before Use
……………….…………… 3
For Your Safety …………...…………. 5
Components ……………….…………. 7
Chapter 2 Installation ……………………………………..
10
Chapter 3 Basic Operation
………………….…………… 34
Chapter 4 Function Settings …………………………… 44
Factory Settings …………..…………….
46
Menu
………………………………….. 48
Function Settings
………...…………… 51
Chapter 5 Description of Knobs and Keys
……………....… 83
Knobs
…………………….…………… 84
Keys ……………………………….…… 87
Chapter 6 Option
…………………………………..………
95
Option List …………………………… 96
Input/Output Terminals ……….……… 98
Input/Output Terminals
(PROCESSOR UNIT) ……………… 99
Remote Controller ……………….…… 100
Additions ……………………………………………………… 101
Disposal ……………………………..… 101
Specifications
………………….……… 102
- 1 -
CHAPTER 1
INTRODUCTION
Thank you for purchasing the KDS-5000BB digital sonar.
We are confident you will enjoy using your unit for many years to come.
This manual provides complete information on safely operating the
KDS-5000BB
.
Please carefully read and follow the safety information so that the KDS-5000BB will perform to the utmost of its ability.
Before Use Symbols
Notice
Turning the Power On/Off
Key Operation
Preventive Measure for Interference in the area of ship congestion
For Your Safety Use Environment
Mounting Conditions
Power Supply
Handling
Components Supplied Components
6
6
7
4
5
5
3
3
4
4
- 2 -
BEFORE USE
SYMBOLS
The following symbols are used in this manual.
Please read this manual carefully and take note of these symbols.
:
DANGER
WARNING
CAUTION
NOTE !
:
:
:
:
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor injury.
Indicates the contents for the user ’s reference.
NOTICE
This manual should be kept on hand to provide your quick reference whenever you need it.
Any use other than that mentioned in this manual is not guaranteed.
The contents of this manual and equipment specifications are subject to change without notice.
No part of this manual may be copied or reproduced without written permission.
- 3 -
BEFORE USE
TURNING the POWER ON/OFF
POWER ON
“Please wait!” appears on the screen. The Transducer unit is automatically lowered if “ TD
AUTO DOWN
– ON ” previously set.
In case “ TD AUTO DOWN – OFF ” is previously set, it is lowered only after pressing the
Lower key ( ↓ ).
POWER OFF
The power is turned off after
“Please wait!” appears on the screen.
The Transducer unit is automatically raised.
KEY OPERATION
A beep sounds when operating key correctly.
Three short beeps sound when operating wrongly or not accepting the operation.
PREVENTIVE MEASURE for INTERFERENCE in the AREA of
SHIP CONGESTION
When the fishing ground is crowded with many fishing boats, the sonar is subject to interference from ultrasonic equipment (echo sounder or sonar) on other boards as well as those on own ship.
As preventive measure for interference the change of the used frequency or the reduction of the transmitting sound pressure level should be taken from the broadband sonar, the dual frequency sonar and the single frequency sonar accordingly.
- 4 -
FOR YOUR SAFETY
USE ENVIRONMENT
WARNING
CAUTION
Keep the unit away from the flammable gas.
Otherwise it causes a fire.
Follow the below proposed conditions for the installation.
Otherwise it causes a fire or an electrical shock.
Away as much as possible from areas where the unit is likely to be exposed to direct water spray and free as much as possible from shocks and engine vibration.
Away as much as possible from areas of high temperatures or areas where the unit is likely to be exposed to direct sunlight.
MOUNTING CONDITIONS
WARNING
CAUTION
Do not install the KDS-5000BB on unstable or uneven surfaces.
Installing the unit tentatively may result in dropping, toppling over or injury.
Follow the below conditions for wirings.
Otherwise it causes heat, a fire or injury.
Run the cables not to touch the rotary obstacles or disturb the operation.
Do not use the cables bent, twisted or stretched by force.
Do not put heavy objects on the cables.
Always turn off the power before connecting or disconnecting the unit.
Pulling the cables may damage the cables themselves and result in fire or electrical shock.
- 5 -
FOR YOUR SAFETY
POWER SUPPLY
WARNING
CAUTION
Use the proper voltage. Otherwise it will result in fire or electrical shock.
Turn on/off the power by ON/OFF keys on the Operation unit.
Turning on/off the power by the switchboard may damage the unit.
Turn off the power when starting the ship engine.
Otherwise it may damage the unit.
HANDLING
DANGER
WARNING
Do not operate the unit while steering.
Otherwise it will cause wrecks.
Do not open the case cover.
There is a risk of electrical shock if you touch the high voltage conductors.
Only qualified personnel should work inside the unit.
Care for sufficient reinforcement and being watertight should be taken when installing the Hull unit.
Otherwise it will cause wrecks.
Use the proper fuse when changed.
Otherwise it could result in serious trouble or fire.
Use the specified power supply cables.
Otherwise it could result in serious trouble or fire.
The Hull unit Gears and Flange Unit need a regular lubrication with grease.
Confirm the voltage between the Flang and the minus terminal of the ship ’s battery does not exceed 0.65 volts after the installation completed.
Use the larger diameter cable if the voltage exceeds 0.65 volts.
Otherwise the damage to the Transducer unit due to the electrolytic corrosion may results.
- 6 -
SUPPLIED COMPONENTS
PROCESSOR UNIT (DPU-510)
Name of item Processor unit DC power cable
COMPONENTS
Communication cable
2m
Type
Q ’TY
DPU-510
1
31524D-1
1
Name of item Operation manual Audio system plug
5m
36213D
1
Fuse
4A
Tapping screw
Type
Q ’TY
KDS-5000BB.OM.E MP-105LC-RoHS FGBO-A-125V-4A
1 1 3
OPERATION UNIT (DOU-520)
Name of item Operation unit
M6x20
4
Mounting bracket Tapping screw
Type
Q ’TY
BOLT KG-B2
2 PCS
DOU-520
1
37376C
1
M4x12
4
- 7 -
COMPONENTS
HULL UNIT (DHU-530)
Name of item Hull unit Shaft guides Gum packing for flange
Crank handle Damper
Type
Q ’TY
Name of item
DHU-5301
1
TD shaft
ESR-1510
3
ESR-1512
1
Fixing collar
Type
Q ’TY
Name of item
ESR-1504 (1411mm)
ESR-160 32679C-2 (1681mm)
ESR-160 32679C-3 (1981mm)
1
Cap bolt Grease
32681D
2
Anp base
OB-63
1
Shift cap
34378D
1 set
Binding band
34924D
1
Bolt set
×8
×8
×8
×8
SUS-M16x65-
Assy
1 set
HEX. ROD wrench
1.5mm
2.5mm
3mm
-
1 each
Type
Q ’TY
SUS-M4x10
4
Name of item Transducer unit
G-100
1
Bath cork
ANP-1
2
HEX. ROD wrench
3mm
5mm
AB-100-1000
2
-
1
-
1 each
Type
Q ’TY
ESR-1603
1
- 8 -
JUNCTION BOX (DJB-540)
Name of item Junction box Fuse
Type
Q ’TY
DJB-540
1
FGBO-A-125V-4A
FGBO-A-125V-8A
3 each
Tapping screw
For
DJB-540
SUS-M5x20
1
COMPONENTS
- 9 -
CHAPTER 2
INSTALLATION
This Chapter explains the installation of KDS-5000BB.
Installation Installation Position of Hull Unit
Dimensions Processor unit (DPU-510)
Dimensions Operation unit (DOU-520)
Dimensions Junction box (DJB-540)
Dimensions Hull unit (DHU-530)
TD tank
Assembling and Mounting of Hull unit (DHU-530)
Mounting Junction Box (DJB-540)
Mounting Processor unit/ Operation unit
Processor unit (Rear Side)
Wiring Junction Box (DJB-540)
Hull unit (DHU-530)
Wiring Warnings
Wiring between Processor unit and Hull unit
Wiring Junction Box (DJB-540)
16
20
27
28
29
30
30
31
32
33
11
12
13
14
15
- 10 -
INSTALLATION
Fully discussion and agreement are required with the ship owner and dock yard in deciding the location for the Hull unit. Give careful considerations to the installations.
INSTALLATION POSITION of HULL UNIT
Select an area where noise, interference and bubbles are minimal.
The point at 1/3 to 1/2 of the ship
’s length from the bow or near the keel is the best.
If the Hull unit cannot be installed on the keel, the center of the retraction TD tank should be within 1 meter of the keel.
Hull Unit
TD tank 1/3
CAUTION
1/2
1 m 1 m
Be sure there are no obstacles to interfere the ultrasonic beam when the Transducer unit is lowered.
Provide sufficient clearance around the TD tank for maintenance and inspection work.
The Bow mark ( △ ) on the Flange should be installed facing the bow. However, if this hinders maintenance or inspection, and there is no solution, direct the mark to the opposite (180°) direction, toward the stern.
- 11 -
INSTALLATION
DIMENSIONS: PROCESSOR UNIT (DPU-510)
DIMENSIONS: OPERATION UNIT (DOU-520)
Unit: mm (inch)
- 12 -
DIMENSIONS: OPERATION UNIT (DOU-520)
- 13 -
INSTALLATION
Unit: mm (inch)
INSTALLATION
DIMENSIONS: JUNCTION BOX (DJB-540)
- 14 -
Unit: mm (inch)
DIMENSIONS: HULL UNIT (DHU-530)
- 15 -
INSTALLATION
Unit: mm (inch)
INSTALLATION
TD TANK
1. MAINTENANCE SPACE
When installing the TD tank, pay full attention to the safety (strength, water-tightness, etc.).
At the same time, secure a space for maintenance and inspections.
- Since the Hull unit is not a waterproof structure, keep it away from water drops and splashes.
When mounting the TD shaft to the Transducer unit, be sure not to damage the TD shaft thread or twist the Transducer unit cable
TD TANK LENGTH (Lt) +181mm
The drawing shows the optional mounting method, the Junction
Box is mounted on the Hull unit.
Draft at the full load
TD shaft
Flange should be positioned over the draft at full load .
TD tank
Keel
Lt + 535
Lt
TD tank length
( min : 670 )
If the working space (LT+535) is not available, provide a hole of a size of at least 300x300mm in the ceiling.
In case the Junction Box is mounted on the Hull unit, it might be required to be separated from the Hull unit or provide a hole of a size of at least 300x300mm in the ceiling if there is no sufficient work space.
Do not protrude TD tank from beneath the keel.
Unit: mm
- 16 -
INSTALLATION
2. TD TANK INSTALLATION CONDITIONS
Satisfy the following installation conditions.
Installation point should be 1/3 to 1/2 of the ship ’s overall length back from the bow.
If it cannot be installed on the keel, the center of the TD tank should be within 1 meter of the keel.
22.5° 22.5° -There should be no obstacles right below the flange to avoid hindering bolt clamping.
FLANGE HOLE ANGLE
-Do not protrude the TD tank from
Space under Flange beneath the keel.
VIBRATION SUPPORT
-Flange should be positioned in parallel with the ship ’s draft and over the draft at
FRP full load.
-Apply FRP sufficiently to all the necessary
KEEL
MAX 1MT
KEEL sections to prevent water leakage.
Not to protrude lower than Keel.
-Make the surrounding of TD tank in a streamline shape and provide a fairing plate to suppress water resistance and generation of air bubbles to the minimum.
-Attach a fin if necessary.
STREAMLINING
BOARD
STREAMLINING
BOARD
Make sure the fin does not hinder bolt clamping for Flange.
DANGER
Fully discuss about the strength and water tightness with the ship owner, the engineer in the shipyard, and the installer before determining on the position, the method of installation, and necessary materials. Otherwise it causes maritime accidents.
- 17 -
INSTALLATION
3. TD TANK INSTALLATION EXAMPLES
HULL
KEEL
TD TANK HOLE
TD TANK
- 18 -
- Select a location of TD tank.
Refer to page 11
-Make a hole of TD tank diameter in the bottom of ship.
Install the TD tank.
Flange should be positioned in parallel with the ship ’s draft in sailing.
< To be continued >
FAIRING PLATE
- 19 -
INSTALLATION
-Make the surrounding of the
TD tank projecting out from the bottom in a stream line shape and provice a fairing plate to suppress water resistance and generation of air bubbles to the minimum.
-Apply FRP sufficiently to all the necessary parts to prevent leakage of water.
INSTALLATION
ASSEMBLING and MOUNTING of Hull unit (DHU-530)
1. TD SHAFT
Calculate necessary length of TD shaft (Standard length of 1681mm) from the length of TD tank (Lt) and cut off the unnecessary portion.
TD SHAFT LENGTH = TD TANK LENGTH (Lt) + 181mm
2. TD SHAFT ADJUSTMENT
1) Cut the TD shaft to the required length,
TD tank length (Lt) + 181mm.
Deburr and taper the edge 90°
2) Deburr the cut piece and taper the edge
(1mm).
(1mm).
M4 Thread
5 mm
3) Bore 4 holes in the TD shaft as follows,
every 90 degrees
5mm from the cut end of the pipe
hole size of φ 3.4
set a tapping screw (M4) on the hole each
In case of sufficient space above the TD shaft it can be used without cutting.
Yt
Yt
Lt+160
MARK
Mark to the point of Lt+160.
The upper end of Joint Arm should be united with the Mark and tighten them. them.
Mark and tighten it.
Lt+Yt+460
When the space above the TD shaft is equal to this, the TD shaft may be used without being cut.
Lt: (min.670)
Unit: mm
- 20 -
INSTALLATION
3. ASSEMBLING of the TD shaft and the Transducer unit
1) Screw TD shaft into the Transducer unit.
Make sure not to damge the TD shaft or twist the Transducer unit Cable.
Totally wipe dirts and grease from the threaded parts of the Transducer unit and TD shaft.
Apply adhesive, waterproof sealer (Bathcork; supplied) to the threaded parts of the TD shaft.
Coat the attached cap bolts with adhesive to prevent an electric corrosion after clamping the
TD shaft securely with cap bolts.
Put a Bow Mark with a felt pen at the top end of the TD shaft as shown in the drawing.
BOW MARK
Mark using and oil-ink felt pen
CAUTION
Pay attention to the following when mounting the
TD shaft into the Transducer unit or demounting the TD shaft from the Transducer unit.
Make sure of the metal parts of Transducer unit fixed and turn the TD shaft side when demounting it from the Transducer unit. Otherwise the
Transducer unit or the Transducer unit Cable gets damaged.
CAUTION
Do not apply any sealants inside the TD shaft.
Otherwise the Transducer unit Cable is adhered and gets damaged when demounting it.
Transducer unit
(4 points)
Apply some adhesive to coat 4 cap bolts.
< To be continued >
- 21 -
INSTALLATION
2) Mount Shaft Guides
Instert the 3 shaft guides as shown in the drawing.
Insert Fixing Collar and fix it with the Cap Bolts (2 pcs).
CAP BOLT M4X10
- 22 -
FIXING COLLAR
SHAFT GUIDES
< To be continued >
INSTALLATION
3) Mount the Transducer unit on the Hull unit
-Apply Grease inside the nuts and the Flange.
-Unscrew the nuts. Pass the TD shaft through the Flange assembly.
Pass the Damper through and align the bow mark on the Transducer unit with the mark on the
Flange assembly. Fix the Joint Arm to the TD shaft.
-Take care the position of the Transducer unit bottom is 48mm up from the TD tank bottom.
-Pass the Fixing Collar into the TD shaft and fasten it with the cap bolts (2 pcs).
21m m
Damper
Fixing Collar
Joint Arm
Refer to the next page to know how to tighten the nuts.
次ページをお読みください。
Flange assembly is shipped with the nuts screwed.
Apply Grease to the TD shaft and the contact surface with the TD shaft.
Align the bow mark when fixing the TD shaft in the Joint Arm.
< To be continued >
- 23 -
INSTALLATION
4 ) Mount the shaft cap at the end of TD shaft
Insert the shaft cap into the TD shaft.
Screw it with the cap bolts, M4x25 (4 pcs).
Screw the cap bolts, M4x10 (4 pcs) to prevent slip-out of the shaft cap.
Ensure the bolt position each.
Cap Bolt
M4 x 25
Shaft cap
Cap Bolt
M4 x 10
5 ) How to tighten the nuts
Lift up the Lock Nut as shown in the drawing. Place the Waterproof Nut on the Flange opening and tighten it firmly by hand and then make a 180-degree turn with a screwdriver.
Take care not to over a 180-degree. This Lock Nut is to protect loosening the Waterproof Nut.
Screw the Lock Nut tightly with a screwdriver and a hammer.
WATER PROOF NUT
180゜
LOCK NUT
After tightening the Water
Proof Nut by hand, use a
Screw Driver to clamp it further by 180 ° .
< To be continued >
- 24 -
INSTALLATION
6 ) Assemble Hull unit with TD tank
Insert Gum Packing between Hull unit and TD tank.
Use 8 Hex.Bolts (M16x65) to fit Hull unit in TD tank.
Check the performance of hoisting/lowering of the Transducer unit several times while tentatively clamping with Hex.Bolts and fasten them after the performance is confirmed.
CAUTION
Apply Grease regularly to the parts of Gear of Hull unit and Flange
Opening.
Nut (M16)
Spring Washer (
φ16)
Flat Washer
(16 x 32 x 2)
Hex.Bolt
(M16 x 65)
TD tank
Fix the Transducer unit cable with a
Nylon Clip.
CAUTION
The sufficient space should be kept not to disturb the raise/lower of the the transducer unit.
Gum Packing for Flange
CAUTION
Do not apply Adhesive, etc. on the
Gum Packing for Flange.
- 25 -
INSTALLATION
4. HOW TO ADJUST HOISTING and LOWERING STROKE
The stroke of hoisting/lowering of the Transducer unit can be adjusted from the minimum,
180mm to the maximum, 380mm by adjusting the switch shown in the drawing.
Find the proper lowering position of the Transducer unit with this Switch.
Loosen the screws and adjust the position.
Moved up and down
Adjustable range (200mm)
Raised Position
380mm
Lowered Position (Max.)
5. MANUAL HOISTING/LOWERING OF TRANSDUCER UNIT
When the Transducer unit cannot be hoisted due to a trouble occurrence, it is possible to raise the Transducer unit with the Crank Handle manually after removing the Cap.
DANGER
Make sure the Hoist Switch is turned off when it is manually operated.
WARNING
Remove the Cap
Hoist Switch is on this side.
Crank Handle
Confirm the voltage between the Flang and the minus terminal of the ship exceed 0.65 volts after the installation completed.
’s battery does not
Use the larger diameter cable if the voltage exceeds 0.65 volts.
Otherwise the damage to the Transducer unit due to the electrolytic corrosion may results.
- 26 -
INSTALLATION
MOUNTING of JUNCTION BOX (DJB-540)
The mounting location should be well ventilated and dry.
Avoid locations subject to watersplash or rain. Allow enough service clearance.
The Cable Junction side should be at the bottom side or the left side.
Cable Junction at the left
Truss Tapping Screw Cable Junction at the bottom
Components
Junction Box 1
Truss Tapping Screw
(M5x20)
4
Use the Junction Box (DJB-504) Mounting Kit to joint the Junction Box to the Hull unit if desired.
Option
OP-700: Junction Box Mounting Kit
Refer to page 96
- 27 -
INSTALLATION
MOUNTING of PROCESSOR UNIT/ OPERATION UNIT
PROCESSOR UNIT
1) Fasten the Processor Unit to the mounting location with 4 Truss Tapping Screws.
Components
Processor Unit
Truss Tapping Screw
1
4
Truss Tapping Screw
OPERATION UNIT
1) Fasten the M. Bracket to the mounting location with 4 Truss Tapping Screws.
2) Fit the Operation unit to the M. Bracket with the Knob Bolts adjusting the comfortable viewing angle of the monitor. Fasten the both knob bolts.
Components
Operation unit
M. Bracket
1
1
WARNING
M. Bracket Truss Tapping Screw
The unit should be installed and fixed on a flat surface.
Otherwise it may cause the trouble.
Truss Tapping Screw
Knob Bolt
CAUTION
Vibration or shock in the mounting area should be minimal.
Locate the unit away from areas subject to water splash or rain.
Otherwise it may causes corrosive trouble .
Locate the unit away from areas subject to heat sources and direct sunlight.
4
2
Knob Bolt
- 28 -
INSTALLATION
PROCESSOR UNIT (REAR SIDE)
USB Terminal for using USB
Speaker Terminal connects an optional speaker.
(4 Ω).
(別売)
Fuse Holder
Use the specified fuse as follows,
24V → 4A.
NAV-IN Terminal (5P) connects an external navigator or NMEA-0183 signal input.
Power Input Terminal connects the DC power supply for activating the
Display Unit.
Use the voltage in the range
21.6 to 31.2Volts.
Alarm Terminal (2P) relay contact for an external alarm
Earth Terminal
Sounder Connecting Terminal
(7P) connects an external Echo
Sounder.
Trigger Output Terminal (3P) outputs trigger signals synchronizing to an external echo sounder.
VGA Output Terminal (OPTION) connects an external monitor
Operation unit Connecting Terminal (10P) connects the Operation unit.
を接続します。
Remote Controller Terminal connects a remote controller
Trigger Input Terminal (8P) synchronizing to an external echo sounder.
VGA Output Terminal connects an external monitor
Input trigger signals
Power Output Terminal (3P) conncets an external monitor Suzuki specified. Output:12VDC
No.1: + No.2: shield No.3: -
NMEA Output Terminal (6P) outputs the data of depth and water temperature.
The Latitude/Longitude of the
Target is output when an external
Navigator connected.
Communication Terminal (10P) connects I/F cable from the
Junction Box
The following optional terminals are available.
・ OPTION
OPTION No. Description
ESR-1809-SET Remote Controller Set
OP-360
OP-190
XGA Connecting Cable
Trigger Output Connecting Cable
Connects this terminal when
Remote Controller used.
Connects this terminal when
External Monitor used.
Connects this terminal when
Trigger output to External Echo
Sounder.
- 29 -
INSTALLATION
WIRING JUNCTION BOX (DJB-540)
Main Fuse
For Main Power Supply of Junction Box
Use the specified fuse as follows,
24V → 4A.
Power Supply Cable connects the DC power supply for activating the Hull unit.Use the voltage in the range
21.6 to 31.2Volts.
I/Fcable connects I/F cable to the Processor unit.
Limit Switch Cable connects the Limit Switch Cable from the Huii unit.
Transducer unit Cable connects the Transducer unit
Cable from the Transducer unit.
Earth Terminal
HULL UNIT (DHU-530)
Hoist Motor Cable connects the Hoist Motor Cable to the Junction Box.
Motor Fuse
For Hoist Motor
Use the specified fuse as follows,
24V → 8A.
Hoist Motor Cable connects the Hoist Motor Cable from the
Hull unit.
Limit Switch Cable connects the Limit Switch Cable to the Junction Box.
- 30 -
INSTALLATION
WIRING WARNINGS
Connect the cables to the Hull unit, the Junction Box, the Processor unit or the Operation unit referring to the following instructions.
WARNING
- The DC Power Supply connected to the main unit each is as follows,
DPU-510 Processor unit : 21.6 to 31.2 volts
DJB-540 Junction Box : 21.6 to 31.2 volts
Connection of an incorrect power supply may cause fire, electrical shock or damage to the units.
- Use the specified power supply cable.
Otherwise fire or generation of heat may result.
- Confirm the voltage between the Flang and the minus terminal of the ship ’s battery does not exceed 0.65 volts after the installation completed.
Use the larger diameter cable if the voltage exceeds 0.65 volts.
Otherwise the damage to the Transducer unit due to the electrolytic corrosion may results.
-Turn off the power and hold the plug when connecting or disconnecting the cable.
Otherwise the cable gets damaged and causes electrical shock or fire.
- Do not bent or twist the cables and not to put the heavy obstacles on the cable.
Wiring positions should not disturb the sailing operation or interfere with walking.
It may cause fire, generation of heat or injury.
- 31 -
INSTALLATION
WIRING between DPU-510 and DHU-530
OPERATION UNIT
BATTERY VOLTAGE: 24V
FUSE: 4A
COMMUNICATION CABLE 1
5m
POWER SUPPLY
CABLE 2m
24V
PROCESSOR UNIT
BATTERY
GND
INTERFACE
CABLE 15m
POWER SUPPLY
CABLE 5m
FUSE
BATTERY VOLTAGE
MAIN
GND
WHITE LINE : PLUS TERMINAL
BLACK LINE : MINUS TERMINAL
VGA OUTPUT
TERMINAL
( POWER )
24V
VV
HOIST MOTOR CABLE
5.3m
LIMIT SWITCH CABLE
5.5m
TRANSDUCER UNIT CABLE
7.7m
HOIST
SWITCH
The length of each cable includes a part (up to 60 cm) for drawing inside the main unit.
- 32 -
INSTALLATION
WIRING JUNCTION BOX (DJB-540)
BATTERY
HOIST MOTOR CABLE connects J2 on the board.
LIMIT SWITCH CABLE connects 6P plug to J 7 on the board.
TRANSDUCER UNIT CABLE connects 3P plug to J 9 on the board. connects 5P plug to J 6 on the board. connects 10P plug to J 5 on the board.
GND
4 BINDING
SCREWS
(M4X8) 4pcs
J 2 connects the white line to
24V according to the voltage of the battery.
J 7
24V
BLACK
J 9
J 5
J 6
- 33 -
CHAPTER 3
BASIC OPERATION
This Chapter explains the basic operation of KDS-5000BB.
Basic Operation Operation Panel
Display Description
Sample Display of Sonar Mode
Sonar Mode
Sample Display of Bottom-Scan Mode
Bottom-Scan Mode
Sample Display of Sounder Mode
Sounder Mode
35
36
37
38
40
41
42
43
- 34 -
BASIC OPERATION
OPERATION PANEL
Sensor Lamp
Refer to page 87
Mark key
Refer to page 93
Cursor Shift Keys
( ▲ / ▼ / / )
Refer to page 90
Target Lock Key
Refer to page 92
Tilt Keys
Refer to page 89
Bearing Keys
Refer to page 88
Range Knob
Refer to page 84
Sector Knob
Refer to page 85
Mode Knob
Refer to page 84
Power ON/OFF Keys
Refer to page 87
Hoist Keys
Refer to page 87
Lower Keys
Refer to page 87
Cursor Selection Keys
(Ring Marker/Cross Cursor)
Refer to page 90
Color rejection Key
Refer to page 93
Operation Mode Keys
Refer to page 94
Far Gain Knob
Refer to page 86
Gain Knob
Refer to page 86
- 35 -
BASIC OPERATION
DISPLAY DESCRIPTION
The drawing below shows the typical sonar mode display.
Various combination displays are available by selecting the Sub-Display menu and the change of the Mode Knobs.
E
S
N
W
RANGE
160m
BEARING
0゜
SECTOR
360゜
TILT
-30゜
IR-1
MARKER
86.0m
99.3m
49.7m
CURSOR
十 45゜
65.2m
75.3m
37.7m
POWER 24.3V
WATER 27.4゜C
SPEED 16.0kt
34゜33.40’N
137゜03.84’E
SCREEN LEFT
SONAR MODE
OFF-CENTER MODE
BOTTOM-SCAN MODE
SOUNDER MODE
Use the MODE KNOB to select the display mode.
SCREEN RIGHT
MENU 1 & SELF CHECK
MENU 2 & SELF CHECK
INFORMATION
SUB-DISPLAYS
Use the MODE KNOB to select MENU 1 & 2.
INFORMATION/SUB-DISPLAYS can be set via
MENU 2 .
MENU 1 ( )
Select the desired 8 ranges.
MENU 2 ( )
Select the desired user settings.
SUB-DISPLAYS
Select the desired sub-display with MENU 2
In case “SUB-DISPLAY – NO SUB DISPLAY” selected the display mode in the left side can be displayed on the whole screen. Refer to page 58
- 36 -
BASIC OPERATION
SAMPLE DISPLAY of SONAR MODE
Select MODE KNOB ( ) to display SONAR MODE or MODE KNOB ( ) to display
OFF-CENTER MODE.
#1
RANGE
#2
HORIZONTAL DISTANCE
SLANT DISTANCE
BEARING
SECTOR
INTERFERENCE
R 160m
B 0゜
S 360゜
IR-ON
86.0m
99.3m
49.7m
DEPTH
REJECTION
MARKER
ECHO
BEARING LINE
SHIP ’S POSITION
+
CROSS CURSOR
SCALE
TILT ANGLE
TRANSDUCER UNIT
POSITION
T-30゜
SEA BOTTOM
+ 45゜
65.2m
75.3m
37.7m
#3
CURSOR BEARING
HORIZONTAL DISTANCE
SLANT DISTANCE
DEPTH
SHIP
’S POSITION
POWER SUPPLY VOLTAGE
WATER TEMP.
SPEED
SHIP ’S POSITION IN
LATITUDE/LONGITUDE
INFORMATION DISPLAY
SHIP
’S POSITION
RAINBOW PATTERN
R A N G E
160m
B E A R I N G
0゜
S E C T O R
360゜
T I L T
-30゜
IR-ON
M A R K E R
86.0m
99.3m
49.7m
C U R S O R
+ 45゜
65.2m
75.3m
37.7m
POWER
WATER
SPEED
24.3V
27.4゜C
16.0kt
34 ゜33. 40'N
137 ゜03. 84'E
- 37 -
When the Sub menus other than
INFORMATION selected,
They are displayed in the upper left of the
Sonar Display (#1). Tilt angle is displayed in the lower left.
“IR-ON” is not displayed when
INTERFERENCE REJECTION OFF selected.
They are displayed in the upper right of Sonar
Display (#2).
They are displayed in the lower right of Sonar
Display (#3).
They are display in the lower right corner of
Sub-Display.
An External Navigator is required to display the ship ’s position and the speed.
BASIC OPERATION
SONAR MODE
Rotating the transducer in the Transducer unit protruded from the ship ’s bottom, the ultra sound beams are sent out and detects the targets in accordance with the selected speed and the range (distance).
The reflected sound appears on the PPI depending on the transducer
’s sweep.
Adjusting the Tilt and Bearing the sonar beam can be trained from the surface to the bottom.
SECTOR ANGLE: 360゜
SWEEP DIRECTION: RIGHT
ULTRA SONIC BEAM
1
2
3
4
5
SECTOR ANGLE: 165゜
The transducer emits the ultra sound beams rotating the Transducer unit.
Changing the sector angle makes it possible to detect in various ranges.
Refer to page 85
1 2 3
4
5
6
7
8
The reflected echoes are displayed accordingly after emitting the ultra sound beam from 1 to 8 shown in the drawing left.
5゚
SECTOR ANGLE
10゚
The transducer rotates with the selected step angle.
The reflected echoes are displayed as the image every step accordingly.
The step angle can be selected in MENU 2 – “STEP (SONAR)” . Refer to page 63
A narrow step gives a more detailed image on the screen, however more sweep time is requested than a wide step
<to be continued>
- 38 -
BASIC OPERATION
The Tilt angle can be set in increments of 1° from 0° to 5° to 0° to -90°.
All directions from extremely shallow waters to deep areas can be searched.
Adjust the tilt angle considering the conditions such as ship ’s speed and water depth.
Tilt angle setting range
5゜
0゜
The below drawing illustrates the fish school is displayed on the screen when the ship reaches the point A, but it is not displayed at the point B even if the same tilt angles are set.
Select an appropriate tilt angle in order to display the fish school at the point B.
A
SEA BOTTOM
B
The setting of the tilt angle is available in the Sonar Mode, Bottom-Scan Mode or Sounder
Mode. Refer to page 89
- 39 -
BASIC OPERATION
SAMPLE DISPLAY of BOTTOM-SCAN MODE
Select MODE KNOB ( ) to display the BOTTOM-SCAN MODE.
SHIP
’S POSITION
TILT ANGLE
T-90゜ B270゜
0
#1
32
#2
SCALE ( RANGE )
64
CROSS CURSOR
RANGE
MARKER
100
SEA BOTTOM ECHO
128
SCALE
(SECTOR)
64 32
0
32
TRANSDUCER UNIT S 95゜
+
-70゜ 75.1m
64
POSITION
138 m
IR-ON 25.7m 70.6m
160
DEPTH #3 #4
The above values of #1, #2, #3 and #4 are not displayed when the Sub-Display menu,
INFORMATION is active.
INFORMATION DISPLAY When the Sub menus other than
SPEED
RANGE
160m
WATER 27.4゜C
INFORMATION selected,
They are displayed in the Bottom Scan
BEARING
270゜
WATER TEMP.
SECTOR
95゜
“IR-ON” is not displayed when
RAINBOW PATTERN
TILT
-90゜
INTERFERENCE REJECTION OFF selected.
IR-O N
----m
CURSOR
十 -70゜
POWER SUPPLY
VOLTAGE
25.7m
75.1m
70.6m
MARKER
----m
----m
They are displayed as the data of the range marker in the Bottom-Scan Mode.
They are displayed in the Bottom-Scan
Mode (#4).
POWER 24.3 V
Mode Display (#1, #2 and #3).
They are displayed in the lower right corner
SHIP
’S POSITION IN SPEED 16.0kt of Sub-Display when an external navigator
LATITUDE AND
34゜33.40’N
137゜03.84’E connected.
LONGITUDE
- 40 -
BASIC OPERATION
BOTTOM-SCAN MODE
Shaking the transducer in the Transducer unit protruded from the ship ’s bottom right and left alternately, it sends out the ultra sound beams and displays the images of the middle layer and the sea-bottom contour.
The transducer emits the ultra sound beams sweeping the transducer right and left.
The reflected echoes are displayed accordingly after emitting the ultra sound beam.
SECTOR ANGLE: 95 ° SECTOR ANGLE: 45 °
Changing the sector angle makes it possible to detect both the narrow and the wide ranges.
Refer to page 85
Changing the tilt angle makes it possible to detect the area of the selected sector angle centering the tilt angle.
Refer to page 89
3゜ 5゜
The transducer moves with the selected step angle.
The reflected echoes are displayed as the image every step accordingly.
The step angle can be selected in
MENU 2 – “STEP (BOTTOM-SCAN) ”.
Refer to page 63
- 41 -
BASIC OPERATION
SAMPLE DISPLAY of SOUNDER MODE
Select MODE KNOB ( ) to display the SOUNDER MODE.
TILT ANGLE WATER TEMPERATURE #6
#1 TIME MARKER
T-60
゜
B 0
゜
24.7 ° C
0
#2
SEA SURFACE
SCALE
64
BEARING ECHO (RANGE)
INDICATOR
96
100
SEA BOTTOM
128
RAINBOW PATTERN RANGE
MARKER
160
105 m IR-ON 50.2m
100m
86.9m
24.3 V 16.0kt 34゜33.40’N
137゜03.84’E
24.7゜C
TRANSDUCER UNIT
POSITION
DEPTH
#3
#4
MARKER
#5
SHIP ’S POSITION
INTERFERENCE
HORIZONTAL
LATITUDE AND
DISTANCE
REJECTION
LONGITUDE
SLANT
SPEED
DISTANCE
POWER SUPPLY
DEPTH
VOLTAGE
The above values of #1, #2, #3, #4, #5 and #6 are not displayed when the Sub-Display,
INFORMATION display is active. The depth display is available only when the tilt angle
–90 ° set.
INFORMATION DISPLAY
When the Sub menus other than
INFORMATION selected,
RANGE
160m
BEARING
0゜
SECTOR
--- ゜
TILT
-60゜
IR-O N
They are displayed in the Sounder Mode
Display (#1, #2 and #3).
“IR-ON” is not displayed when
INTERFERENCE REJECTION OFF selected.
They are displayed as the data of the range
POWER SUPPLY
VOLTAGE
MARKER
100m
50.2m
86.9m marker in the Sounder Mode Display (#4).
WATER TEMP.
SPEED
SHIP
’S POSITION IN
CURSOR
十 ---゜
----m
----m
----m
They are not displayed in the Sounder
Mode Display.
LATITUDE AND
LONGITUDE
POWER 24.3 V
WATER 27.4゜C
SPEED 16.0kt
They are displayed in the lower right corner of
Sub-Display (#5). The latitude/longitude and
34゜33.40’N
137゜03.84’E the speed of the ship are displayed only when an external navigator connected.
- 42 -
BASIC OPERATION
SOUNDER MODE
The transducer in the Transducer unit protruded from the ship ’s bottom sends out the ultra sound beams and displays the images of the middle layer and the sea-bottom contour, which are just beneath the ship.
Sounder Mode
The transducer emits the ultra sound beams toward the bottom just beneath the ship and the images are displayed like the Echo
Sounder. The beam width is different depending on the frequency.
Detects beneath the ship.
Detects fore by changing the tilt angle The images other than beneath the ship can be displayed by changing the tilt angle and the
Tilt angle bearing.
Refer to page 88/89/90
Detects starboard by changing the tilt angle and the bearing.
- 43 -
CHAPTER 4
FUNCTION SETTINGS
This Chapter explains the function settings of KDS-5000BB.
Select the appropriate setting for performing to the utmost of its ability before use.
Factory Settings
Menu
Function Settings
Function Set
Menu 1
Menu 2
Gain Up
TVG Curve
Dynamic Range
Pulse Width
TX Power
RX Gain Reduction
RX Bandwidth
Full-Screen Gain Set
Rejection
Display Item Selection Sub-Display
Step (Sonar)
Step (Bottom-Scan)
Off-Center Position
Scale Dots
Compass Display
Heading Display
Track Display
Track Sub Range
55
55
56
56
57
58
63
63
64
64
65
65
65
66
Track Mem.Interval (Track Memory Interval) 66
Press Rate (Compressed Rate)
Filter
Sub Bottom-Scan
Cursor Direction
Cursor Position
46
48
49
51
52
53
54
54
66
67
67
67
67
< To be continued >
- 44 -
Others
Color Palette
Remote Control Set
Frequency Setting
Self Check
Maintenance
Audio Level
Target Lock
Trigger Signal
Depth Unit
Temp. Unit (Temperature Unit)
Temp. Adjust (Temperature Adjustment) 71
Speed Unit 72
Auto Retract
Train Correct
72
73
Panel Brightness
Power Supply Frequency
TD Auto Down
Ope. Mode Memory
73
74
74
75
68
69
70
71
71
Color Sel. (Color Selection)
Color (Display Colors)
TX Frequency
RX Frequency
Update
Backup
Recovery
Version
80
81
82
82
82
78
79
79
76
76
- 45 -
FACTORY SETTINGS
FACTORY SETTINGS
The factory settings are shown in the below box. Select the desired settings before use.
FUNCTION SETTINGS FACTORY SETTINGS (shown in AA) Referring page
FUNCTION SET
GAIN UP OFF +10dB +20dB +30dB +40dB +50dB
TVG CURVE
DYNAMIC RANGE
PULSE WIDTH
OFF 10LOG 20LOG 30LOG 40LOG
1 dB 2 dB 3 dB
X1 X1.5 x2
A B C D TX POWER
RX GAIN RED.
RX BANDWIDTH
OFF ON
S. WIDE WIDE STANDARD
NARROW S. NARROW
FULL –SCREEN GAIN SET OFF ON
REJECTION
INTERFERENCE REJ OFF ON
DISP ITEM SEL
SUB-DISPLAY
COMPASS DISP.
+A-SCOPE BOTTOM TRACK EXTSOUNDER
STEP (SONAR) 5° 10° 15° 20°
STEP (BOTTOM-SCAN) 3° 5°
OFF-CENTER POS.
SCALE DOTS
FORE BACK LEFT RIGHT
OFF ON
OFF ON
HEADING DISP.
TRACK DISP.
NO SUB-DISP. INFO HISTORICAL +PRESS
OFF ON
OFF ON
TRACK SUB RANGE 50m (10-500 depth unit)
TRACK MEM. INTERVAL 5 SEC 10 SEC 30 SEC 60 SEC
PRESS RATE 1/2 1/4 1/8 1/16
FILTER
SUB BOTTOM-SCAN
OFF 1 2
AUTO MANUAL
CURSOR DIRECTION
CURSOR POSITION
R-DIRECTION T-DIRECTION
DISTANCE LAT/LONG
OTHERS
AUDIO LEVEL
TARGET LOCK
TRIGGER SIGNAL
DEPTH UNIT
TEMP. UNIT
TEMP. ADJUST
0 (0-31)
MODE0 MODE1 MODE2 MODE3
INTERNAL EXTERNAL m ft fm br
°C °F
SPEED UNIT
AUTO RETRACT
+0.0°C ( -9.9° ~ +9.9°) kt km/h
OFF 1kt (1~27km/h or 1kt ~15kt)
TRAIN CORRECT 0° (0°- 355°)
PANEL BRIGHTNESS 15 (0 - 15)
POWER S. FREQUENCY 120k 125k 130k
TD AUTO DOWN OFF ON
OPE.MODE MEMORY OFF ON
MENU 2
PAGE 51-56
PAGE 57
PAGE 58-67
PAGE 68-75
- 46 -
COLOR PALETTE
COLOR SEL.
COLOR
A-1 A-2 B-1 B-2 C-1 C-2
8 16
FREQUENCY SETTING
TX FREQUENCY 180.0
k Hz (±10kHz / 0.1kHz UNIT)
180.0
k Hz (±10kHz / 0.1kHz UNIT) RX FREQUENCY
FACTORY SETTINGS
MENU 2
PAGE 76-77
PAGE 79
- 47 -
MENU
MENU 1 “ ”
(RANGE SETTING MENU)
Select the display range in 8 settings according to the depth desired.
The following menu appears after selecting
“ ” with the MODE KNOB.
RANGE SET MENU
SONAR/OFF-CENTER RANGE
BOTTOM-SCAN/F.F. RANGE
Use the Cursor Shift key or to highlight the item to change.
Press the Cursor Selection key O / + to display the following range setting menu.
The range can be set freely as desired every 10 units of depth measurement until 2000 units in case of the units, meters, braccia, and fathoms and every 20 feet until 6000 feet in case of the unit, feet.
SONAR/OFF-CENTER RANGE
( BOTTOM-SCAN/F.F. RANGE)
RETURN MARK
1
2
3
40 m
80 m
120 m
4
5
160 m
200 m
Use the Cursor Shift key ( or select the range number desired.
Press the Cursor Shift key ( or set the range.
Cursor Shift keys
: set the value smaller
: set the value larger
) to
) to
6
7
8
240 m
280 m
320 m
These numbers correspond to the Range Knob numbers.
The initial range setting values of both ranges are different each.
Displayed unit of depth measurement can be set via MENU 2 “ OTHERS ”. Refer to page 71
The way of the range setting is the same for both ranges, but the values of range setting are not corresponded each other. The settings for both ranges are required.
In the range settings for SONAR/OFF-CENTER MODE, the range is changed in accordance with the value of SONAR MODE when the Cursor Shift key ( or ) pressed. However,
1.5 times of range of SONAR MODE is displayed when OFF-CENTER MODE selected.
- 48 -
MENU 2 “ ” (FUNCTION SETTING MENU)
Customize the functions to suit individual needs before using the KDS-5000BB.
The basic settings are as follows.
FUNCTION SET GAIN UP
TVG CURVE
REJECTION
DISP ITEM SEL
DYNAMIC RANGE
PULSE WIDTH
TX POWER
RX GAIN RED.
RX BANDWIDTH
FULL-SCREEN GAIN SET
INTERFERENCE REJECTION
SUB-DISPLAY
(DISPLAY ITEM SELECTION) STEP (SONAR)
STEP (BOTTOM-SCAN)
OFF-CENTER POSITION
SCALE DOTS
COMPASS DISPLAY
HEADING DISPLAY
TRACK DISPLAY
TRACK SUB RANGE
TRACK MEMORY INTERVAL
PRESS RATE
FILTER
SUB BOTTOM-SCAN
CURSOR DIRECTION
CURSOR POSITION
OTHERS AUDIO LEVEL
TARGET LOCK
TRIGGER SIGNAL
DEPTH UNIT
TEMPERATURE UNIT
TEMPERATURE ADJUST
SPEED UNIT
AUTO RETRACT
TRAIN CORRECT
PANEL BRIGHTNESS
POWER SUPPLY FREQUENCY
TD AUTO DOWN
OPERATION MODE MEMORY
- 49 -
MENU
MENU
COLOR PALETTE COLOR SEL.
REMOTE CONTROL
SELF CHECK
MAINTENANCE
COLOR
FREQUENCY SETTINGS TX FREQUENCY
RX FREQUENCY
UPDATE
BACK UP
RECOVERY
VERSION
For further details see next pages.
- 50 -
FUNCTION SETTINGS
Turn the MODE KNOB to
“ ” to display the below menu.
The item currently selected is highlighted.
Use the Cursor Shift key ( or ) to select the desired item.
Press the Cursor Selection key O / + to open the menu for change.
MENU 2
FUNCTION SET
REJECTION
DISP ITEM SEL.
OTHERS
COLOR PALETTE
REMOTE CONTROL SET
Use the Cursor Shift key ( or ) to select the desired item.
Press the Cursor Selection key
O / + to open the menu for change.
FREQUENCY SETTING
SELF CHECK
MAINTENANCE
FUNCTION SET MENU
FUNCTION SET
RETURN MARK
GAIN UP
TVG CURVE
OFF
30LOG
DYNAMIC RANGE
PULSE WIDTH
TX POWER
RX GAIN RED
RX BANDWIDTH
3dB
X1
D
OFF
STANDARD
FULL-SCREEN GAIN SET OFF
GAIN GO TO
80dB
60dB
40dB
20dB
1m 10m 100m 1000m
Press the Cursor Selection key O / + to return to MENU 2.
Use the Cursor Shift key ( or ) to select the desired item to change.
Use the Cursor Shift key ( or ) to change the settings.
TVG (Time-Varying-Gain) Curve reflects various changes such as TVG
Curve, Gain Adustment, Gain/Far Gain knobs.
- 51 -
FUNCTION SETTINGS
1. GAIN UP
This function makes it possible to display a clearer picture of the full range and control the sensitivity at various depths.
Use the Cursor Shift key ( or ) to select “ GAIN UP ”.
Use the Cursor Shift key ( or ) to change the setting.
GAIN UP OFF Use the Cursor Shift key ( or ) to change.
[OFF, +10dB, +20dB, +30dB, +40dB, +50dB]
3.3
1/3 2/3
6.6
0 10
この幅は
0
3.3
6.6
10
0
3.3
6.6
10
0
3.3
0
3.3
0
6.6
3.3
10
6.6
10
6.6
10
+50dBの場合
The
“sensitivity” or possibly “volume” is increased 3.3 times when the gain setting is changed to “+10dB” from “OFF”.
The reflected image at level
“3.3” in the gain setting “OFF” is the one at level “0” in the
Gain setting “+10dB”.
TVG Curve changes in accordance with the change of the values of GAIN UP.
・ 0 …10 …20 …30 …40 …50と 変 わ る
80dB
60dB
40dB
20dB
G 0 T 0
+50dB
+40dB
+30dB
+20dB
+10dB
OFF
1m 10m 100m 1000m
The setting values shown in the above drawing are as follows,
Gain Knob: 0
Far Gain Knob: 0
TVG Curve: 30LOG
- 52 -
FUNCTION SETTINGS
2. TVG CURVE
TVG (Time Variable Gain) offsets the effects of propagation loss of sound as it passes through the water. To counter this loss, the TVG curve is adjusted by correctly set.
Use the Cursor Shift key ( or ) to select “ TVG CURVE ”.
Use the Cursor Shift key ( or ) to change the setting.
TVG CURVE 30LOG Use the Cursor Shift key ( or ) to change.
[OFF, 10LOG, 20LOG, 30LOG, 40LOG]
TVG CURVE
OFF: No TVG curve
10LOG: 1 in the below drawing
20LOG: 2 in the below drawing
30LOG: 3 in the below drawing
40LOG: 4 in the below drawing
HIGH
④
③
GAIN
②
①
LOW
0 10 100 10 00 m
NEAR DISTANCE FAR
NOTE!
Caution should be taken to select the TVG curve of which TVG setting is related to the
Gain Knob functions.
- 53 -
FUNCTION SETTINGS
3. DYNAMIC RANGE
This is the way to display the reactions with emphasis or with density discrimination.
Use the Cursor Shift key ( or ) to select
“
DYNAMIC RANGE
”.
Use the Cursor Shift key ( or ) to change the setting.
DYNAMIC RANGE 3dB Use the Cursor Shift key ( or ) to change.
[1dB, 2dB, 3dB]
COLOR SCALE
3dB 2dB 1dB weak blue
blue echoes
blue strong red red red
The selected level is reflected to the Color
Scale as shown in the left.
The weaker reflections are eliminated and the stronger reflections are displayed when selecting rather 2dB than 3dB or 1dB than
2dB.
1dB than 2dB.
4. PULSE WIDTH
This is the way to select the transmitted pulse width.
Use the Cursor Shift key ( or ) to select “ PULSE WIDTH ”.
Use the Cursor Shift key ( or ) to change the setting.
PULSE WIDTH x 1 Use the Cursor Shift key ( or ) to change.
[x1, x1.5, x2] x1 : standard (shown in the below box) x 1.5 : 1.5 times of standard x 2 : 2 times of standard for longer range detection
RANGE (m) PULSE WIDTHE (ms)
0 - 59 0.25
60 - 79
80 - 99
100 - 119
120 - 159
0.40
0.75
0.90
1.00
RANGE (m) PULSE WIDTHE (ms)
160 - 199
200 - 239
240 - 399
400 - up
1.25
2.00
2.50
3.75
- 54 -
FUNCTION SETTINGS
5. TX POWER
The output power of the ultra sound wave from the transmitter can be set.
Use the Cursor Shift key ( or ) to select
“
TX POWER
”.
Use the Cursor Shift key ( or ) to change the setting.
TX POWER D Use the Cursor Shift key ( or ) to change.
[A, B, C, D]
D is the maximum level and A is the minimum level.
6. RX GAIN REDUCTION
Reduction of RX gain to weaken too strong reaction in the shallow water can be set.
Use the Cursor Shift key ( or ) to select
“
RX GAIN REDUTION
”.
Use the Cursor Shift key ( or ) to change the setting.
RX GAIN RD.
OFF Use the Cursor Shift key ( or ) to change.
[ON, OFF]
ON : reduces the RX gain.
OFF: no change.
- 55 -
FUNCTION SETTINGS
7. RX BANDWIDTH
RX bandwidth can be set.
Use the Cursor Shift key ( or ) to select
“
RX BANDWIDTH
”.
Use the Cursor Shift key ( or ) to change the setting.
RX BANDWIDTH STANDARD Use the Cursor Shift key ( or ) to change.
[S. WIDE, WIDE, STANDARD, NARROW, S. NARROW]
NOTE!
Selecting wider bandwidth makes the resolution higher, but more noise.
Selecting narrower bandwidth makes the resolution lower, but less noise.
8. FULL-SCREEN GAIN SET
Select full gain function ON or OFF when changing the gain knob.
Use the Cursor Shift key ( or ) to select “ FULL-SCREEN GAIN SET ”.
Use the Cursor Shift key ( or ) to change the setting.
FULL-SCREEN GAIN SET ON Use the Cursor Shift key ( or ) to change.
[ON, OFF]
ON : the gain is changed on the full screen at the same time when changing the gain knob.
OFF: the gain is changed from the point of changing the gain knob.
- 56 -
FUNCTION SETTINGS
REJECTION
[MODE KNOB – – REJECTION]
REJECTION
RETURN MARK
INTERFERENCE REJ. OFF
O / + to return to MENU 2.
Use the Cursor Shift key ( or ) to select the desired item to change.
Use the Cursor Shift key ( or ) to change the settings.
1. INTERFERENCE REJECTION
This function can be used to eliminate noise from other ships.
Use the Cursor Shift key ( or ) to select
“
INTERFERENCE REJ.
”.
Use the Cursor Shift key ( or ) to change the setting.
INTERFERENCE REJ OFF Use the Cursor Shift key ( or ) to change.
[ON, OFF]
ON : activates this function.
OFF: inactivates this function.
- 57 -
FUNCTION SETTINGS
DISPLAY ITEM SELECTION
DISP ITEM SEL
RETURN MARK
SUB-DISPLAY
STEP (SONAR)
STEP (BOTTOM-SCAN)
OFF-CENTER POS.
SCALE DOTS
COMPASS DISP.
HEADING DISP.
TRACK DISP.
TRACK SUB RANGE
TRACK MEM. INTERVAL
PRESS RATE
FILTER
SUB BOTTOM-SCAN
CURSOR DIRECTION
CURSOR POSITION
Press the Cursor Selection key
O / + to return to MENU 2.
Use the Cursor Shift key ( or ) to select the desired item to change.
Use the Cursor Shift key ( or ) to change the settings.
1. SUB-DISPLAY
Sub menu displayed on the right half of the screen can be selected.
Use the Cursor Shift key ( or ) to select
“
SUB-DISPLAY
”.
Use the Cursor Shift key ( or ) to change the setting.
SUB-DISPLAY INFO Use the Cursor Shift key ( or ) to change.
[NO SUB-DISP., INFO, HISTORICAL, +PRESS, + A-SCOPE, BOTTOM, TRACK,
EXTSOUNDER]
1) NO SUB-DISP. (NO SUB-DISPLAY)
The SUB-DISPLAY is not displayed. SONAR MODE, OFF-CENTER MODE,
BOTTOM-SCAN MODE or SOUNDER MODE is displayed on the whole screen.
- 58 -
FUNCTION SETTINGS
2) INFO (INFORMATION)
This sub menu “INFO” can be displayed when one of the Mode Knobs, “
”selected.
RANGE
160m
BEARING
0゜
SECTOR
360゜
TILT
-30゜
IR-O N a b c d e
MARKER
86.0m
99.3m
49.7m f
CURSOR
十 45゜
65.2m
75.3m
37.7m g
POWER 24.3 V
WATER 27.4゜C
SPEED 16.0kt
34゜33.40’N
137゜03.84’E h i a) Displays the selected range by using the Range Knob desired. b) Displays the selected bearing angle by using the Bearing Key. c) Displays the selected sector angle by using the Sector Knob. d) Displays the selected tilt angle by using the Tilt Key. e) It appears only when Interference Rejection-ON selected. f) Displays the horizontal distance, slant distance and depth to the marker.
No data appears when Bottom-Scan mode set. g) Displays the horizontal distance, slant distance and depth to the cursor.
No data appears when Sounder mode set. h) Displays the power supply voltage and the temperature. i) Displays the ship’s speed and own ship’s position in latitude/longitude.
Note that an External Navigator is required to display these values.
- 59 -
FUNCTION SETTINGS
3) HISTORICAL DISPLAY
The vertical images can be displayed as sub menu when SONAR MODE or BOTTOM-
SCAN MODE set.
Note that the normal echo sounder images are displayed on the whole screen when
SOUNDER MODE is selected.
PORT SIDE MARK・STARBOARD SIDE MARK
3 2
0
PORT SIDE:
YELLOW
BOW: WHITE
STERN: BLUE
SWEEPING STARBOARD: RED
64
96
128
BEARING MARK
24.3 V
160
18.6kt 34゜36.974N
137゜01.698E
24.7゜C
COLOR SCALE
VOLTAGE
WEAK weakest color
(background color)
COUNTERCLOCKWISE : YELLOW
OWN SHIP'S POSITION
CLOCKWISE : BLUE
AN EXTERNAL NAVIGATOR IS REQUIRED.
WATER TEMPERATURE
SIGNAL STRENGTH
STRONG second strongest color strongest color
NOTE: The displayed color varies in related to the signal (echo) strength.
PORT SIDE MARK・STARBOARD SIDE MARK
BOW DIRECTION
WHITE
PORT DIRECTION
YELLOW
STARBOARD
DIRECTION
RED
BEARING MARK
SWEEPING
CLOCKWISE
: BLUE
SWEEPING
COUNTERCLOCKWISE
: YELLOW
BLUE
STERN DIRECTION
The color shows the position/direction currently the beam passes.
- 60 -
FUNCTION SETTINGS
4) +PRESS (COMPRESSED IMAGE AND HISTORICAL DISPLAY)
The vertical images and their compressed image can be displayed when SONAR MODE or
BOTTOM-SCAN MODE set. The normal echo sounder images and compressed image are displayed on the screen when SOUNDER MODE is selected.
SONAR MODE
BOTTOM-SCAN MODE
SOUNDER MODE
T-90° B °
0
PRESS HISTORICAL PRESS DISPLAY NORMAL DISPLAY
32
DISPLAY DISPLAY
(compressed
64
image)
96
100
32
64
96
0
128
128
24.3V 18.6kt
160
34°36.974N
137 °01.698E
24 .7 °C
106 m I R - ON
100m
→ 0. 0m ↓100m
24.3V 16.0kt
160
34 °33.40'N
137°03.84'E
24 . 7°C
Compressed images are displayed at the selected rate [MENU-DISP ITEMSEL-
PRESS RATE].
5) +A-SCOPE (HISTORICAL DISPLAY+A-SCOPE)
A-Scope is displayed on the right side of the historical display.
The illustration below shows when SONAR MODE/BOTTOM SCAN MODE selected.
It is also displayed on the right side of the screen when SOUNDER MODE selected.
A-Scope
24.3V 18.6kt
32
64
96
0
128
160
34°36.974N
137°01.698E
24 .7°C
- 61 -
FUNCTION SETTINGS
6) BOTTOM-SCAN
The images of BOTTOM-SCAN MODE can be displayed in the sub-display.
Note that this function is not available in Sounder Mode. Refer to page 67
-The setting values such as Range, Bearing,
Sector, Tilt for the Bottom-Scan mode can be set
サイドスキャン
R 40m
B 270 ゚
S 175 ゚
T -90 ゚ while the Bottom-Scan mode is active.
The setting values will not be changed even if it backs to the Sonar Mode.
-The Sonar Mode display changes into the
Bottom-Scan when it passes the center while clockwise rotating when “ SUB BOTTOM-SCAN /
AUTO
” selected. After it updated, it will back to the Sonar Mode.
-The Sonar Mode display alternates with the
Bottom-Scan display each time the Lower ↓ key
18.6kt 34゜36.974N
137゜01.698E
24.7゜C pressed when
“
SUB BOTTOM-SCAN /
MANUAL ” selected. The scanning direction is determined by the position when the Sonar
Mode changes into the Bottom Scan.
7) TRACK
Own ship
’s position can be displayed when an external navigator connected.
SCREEN WIDTH
200m
Displays the screen width selected via
“TRACK SUB RANGE” selected.
OWN SHIP
Displays Own Ship ’s position in latitude/longitude and the speed at the bottom of the screen.
MARK
Displays the mark placed by a Cross Cursor in the
Sonar Mode.
TRACK
Displays the track line.
18.6kt 34゜36.974N
137゜01.698E
24.7゜C
The past line is memorized every interval set via
“TRACK MEM.INTERVAL”.
8) EXT.SOUNDER (EXTERNAL SOUNDER)
This function is only available when some Koden units connected.
- 62 -
FUNCTION SETTINGS
2. STEP (SONAR)
The Step angle for SONAR MODE can be selected.
Use the Cursor Shift key ( or ) to select
“
STEP (SONAR)
”.
Use the Cursor Shift key ( or ) to change the setting.
STEP (SONAR) 10 ° Use the Cursor Shift key ( or ) to change.
[5°, 10°, 15°]
5゜
5゜ STEP
3. STEP (BOTTOM-SCAN)
5゜
( or 15°) ( or 15°)
10゜
10゜
10゜ STEP
The Step angle for SONAR MODE can be selected.
Use the Cursor Shift key ( or ) to select “ STEP (BOTTOM-SCAN) ”.
Use the Cursor Shift key ( or ) to change the setting.
STEP (BOTTOM-SCAN) 5 ° Use the Cursor Shift key ( or ) to change.
[3° or 5°]
3゜
STEP 5゜
STEP
NOTE!
3゜
3゜
5゜
5゜
The superior detection images can be obtained when the narrower step angle selected, but the longer detection time is required.
- 63 -
FUNCTION SETTINGS
4. OFF-CENTER POS. (OFF-CENTER POSITION)
The displayed position of own ship on the screen can be selected when OFF-CENTER
MODE is active.
Use the Cursor Shift key ( or ) to select “ OFF-CENTER POS.
”.
Use the Cursor Shift key ( or ) to change the setting.
OFF-CENTER POS.
FORE Use the Cursor Shift key ( or ) to change.
[FORE, BACK, RIGHT, LEFT]
FORE BACK RIGHT LEFT
↓ shows Own Ship ’s Position
5. SCALE DOTS
The display of scale dots on the screen can be selected ON/OFF.
Use the Cursor Shift key ( or ) to select “ SCALE DOTS ”.
Use the Cursor Shift key ( or ) to change the setting.
SCALE DOTS ON Use the Cursor Shift key ( or ) to select.
[ON, OFF]
ON: activates Scale
OFF: inactivates Scale ON OFF
SCALE
When “OFF” set, Scale does not appear on SONAR MODE/OFF-CENTER MODE screens.
However, it appears on BOTTOM-SCAN MODE/SOUNDER MODE screens even if “OFF” set.
- 64 -
FUNCTION SETTINGS
6. COMPASS DISPLAY
Compass can be displayed in the SONAR MODE when an External Navigator connected.
Use the Cursor Shift key ( or ) to select
“
COMPASS DISP.
”.
Use the Cursor Shift key ( or ) to change the setting.
COMPASS DISP. OFF Use the Cursor Shift key ( or ) to change.
[ON, OFF]
S
ON: activates Compass display
W
OFF: inactivates Compass display
E
7. HEADING DISPLAY
Heading line can be displayed in the SONAR MODE.
Use the Cursor Shift key ( or ) to select
“
HEADING DISP.
”.
Use the Cursor Shift key ( or ) to change the setting.
HEADING DISP.
OFF Use the Cursor Shift key ( or ) to select.
[ON, OFF]
Heading Line
ON: activates Heading line display
OFF: inactivates Heading line display
8. TRACK DISPLAY
Track line can be displayed in the SONAR MODE when an external navigator connected.
Use the Cursor Shift key ( or ) to select “ TRACK DISP.
”.
Use the Cursor Shift key ( or ) to change the setting.
TRACK DISP.
OFF Use the Cursor Shift key ( or ) to change.
[ON, OFF]
ON: activates Track line display
OFF: inactivates Track line display
TRACK DISPLAY
- 65 -
FUNCTION SETTINGS
9. TRACK SUB RANGE
The screen width for Track display in sub menu can be selected. Refer to page 62
Use the Cursor Shift key ( or ) to select
“
TRACK SUB RANGE
”.
Use the Cursor Shift key ( or ) to change the setting.
TRACK SUB RANGE 50m Use the Cursor Shift key ( or ) to change.
[10 – 500 depth unit]
Cursor Shift keys
: sets the value smaller.
: sets the value larger.
10. TRACK MEM. INTERVAL (TRACK MEMORY INTERVAL)
The tracking interval can be selected.
Use the Cursor Shift key ( or ) to select “ TRACK MEM. INTERVAL ”.
Use the Cursor Shift key ( or ) to change the setting.
TRACK MEM. INTERVAL 5SEC Use the Cursor Shift key ( or ) to change.
[5 SEC, 10 SEC, 30 SEC, 60 SEC]
The short interval can provide for the display of smooth wake line, but it is the record of short term. In case of the long interval it displays the record of long term, but the zigzag line appears on the screen.
Interval Memorized Time
5 seconds : 8 minutes 20 seconds
10 seconds : 16 minutes 40 seconds
30 seconds : 50 minutes
60 seconds : 100 minutes
11. PRESS RATE (COMPRESSED RATE)
The compressed rate for images on the screen can be selected. Refer to page 61
Use the Cursor Shift key ( or ) to select “ PRESS RATE ”.
Use the Cursor Shift key ( or ) to change the setting.
PRESS RATE 1/4 Use the Cursor Shift key ( or ) to change.
[1/2, 1/4, 1/8, 1/16]
Compress rate 1/2 shows one line for 2 sound beams and 1/4 for 4 sound beams.
The information for the long time can be displayed when the higher rate selected, but the compressed image is tighter.
- 66 -
FUNCTION SETTINGS
12. FILTER
The image on the sonar can be enhanced by this function.
Use the Cursor Shift key ( or ) to select “ FILTER ”.
Use the Cursor Shift key ( or ) to change the setting.
FILTER 1 Use the Cursor Shift key ( or ) to change.
[OFF, 1, 2]
OFF : inactivates filter function.
1 : enhances the image on the sonar.
2 : enhances further the image on the sonar.
13. SUB BOTTOM-SCAN
Select the SUB BOTTOM-SCAN MODE. Refer to page 61
Use the Cursor Shift key ( or ) to select “ SUB BOTTOM-SCAN ”.
Use the Cursor Shift key ( or ) to change the setting.
SUB BOTTOM SCAN AUTO Use the Cursor Shift key ( or ) to change.
[AUTO, MANUAL]
AUTO : Sonar Mode changes into BOTTOM-SCAN MODE automatically .
MANUAL : Sonar Mode changes into BOTTOM-SCAN MODE display manually.
14. CURSOR DIRECTION
Select the display way of the CUSOR DIRECTION when an External Navigator connected.
Use the Cursor Shift key ( or ) to select “ CURSOR DIRECTION ”.
Use the Cursor Shift key ( or ) to change the setting.
CURSOR DIRECTION R-DIRECTION Use the Cursor Shift key ( or ) to change.
[R-DIRECTION, A-DIRECTION]
R-DIRECTION (RELATIVE DIRECTION) : corresponds to the ship ’s heading direction
T-DIRECTION (TRUE DIRECTION) : corresponds to the compass direction
15. CURSOR POSITION
Select the display way of CUSOR POSITION when an External Navigator connected.
Use the Cursor Shift key ( or ) to select “ CURSOR POSITION ”.
Use the Cursor Shift key ( or ) to change the setting.
CURSOR POSITION DISTANCE Use the Cursor Shift key ( or ) to change.
[DISTANCE, LAT/LONG]
DISTANCE : displays the distance of the cursor position
LAT/LONG : displays the cursor position in latitude/longtude.
- 67 -
FUNCTION SETTINGS
OTHERS
[MODE KNOB – – OTHERS]
OTHERS
RETURN MARK
AUDIO LEVEL
TARGET LOCK
0
MODE0
TRIGGER SIGNAL
DEPTH UNIT
TEMP. UNIT
TEMP. ADJUST
SPEED UNIT
AUTO RETRACT
TRAIN CORRECT
PANEL BRIGHTNESS
POWER S.FREQUENCY
TD AUTO DOWN
INTERNAL m
°C
+0.0°C kt
OFF
0°
15
120k
OFF
Press the Cursor Selection key
O / + to return to MENU 2.
Use the Cursor Shift key ( or ) to select the desired item to change.
Use the Cursor Shift key ( or ) to change the settings.
OPE. MODE MEMORY OFF
Note that the value of Train Correct cannot be set here. Refer to page 73
1. AUDIO LEVEL
The audio volume can be selected when connecting an external speaker.
Use the Cursor Shift key ( or ) to select “ AUDIO LEVEL ”.
Use the Cursor Shift key ( or ) to change the setting.
AUDIO LEVEL 0 Use the Cursor Shift key ( or ) to change.
[0 – 31]
Cursor Shift keys
: sets the value smaller.
: sets the value larger.
NOTE!
A speaker device (4
Ω) is required. Refer to page 29
- 68 -
FUNCTION SETTINGS
2. TARGET LOCK
The desired target lock function can be selected, which is activated by pressing the Target
Lock key ( ) while SONAR MODE or BOTTOM-SCAN MODE (only in case of MODE0) operated. It can change the rotary direction, trackthe target or the position specified with a cursor automatically.
Use the Cursor Shift key ( or ) to select
“
TARGET LOCK
”.
Use the Cursor Shift key ( or ) to change the setting.
TARGET LOCK MODE0 Use the Cursor Shift key ( or ) to change.
[MODE0, MODE1, MODE2, MODE3]
MODE 0 (REVERSE)
Each press of the Target Lock key reverses the sector rotary direction.
Note that the automatic tracking is not available in this MODE 0.
MODE 1 (RIGHT - LEFT)
Press the Target Lock key to track the reaction automatically.
“ TARGET LOCK ” sign appears on the upper left corner of the screen or on the display position of BEARING and SECTOR in the INFORMATION display. MODE 1 reverses the
Transducer unit train direction only right and left and track the target automatically.
TARGET
LOCK
If it should have lost the target after a 60° reverse sweep, this function is released.
MODE 2 (UP-DOWN, RIGHT-LEFT)
One time of up and down detection is added after 3 times of MODE1 detection.
Other actions are the same with MODE 1.
- 69 -
FUNCTION SETTINGS
MODE 3
Target mark appears on the screen and tracks the target automatically after placing the Cross cursor on the target and press the Target Lock key.
Target mark moves along with the own ship on the screen.
T Target mark also appears on the sub menu if
TRACK is selected.
TARGET
MARK
TARGET MARK
NOTE!
Tilt and Bearing keys are inoperative while Target lock function is active.
Target lock function is released when Range, Sector and Display mode changed.
Bearing and Sector angles will back to the original values when Target Lock function is released. The value of Tilt angle of activating Target lock remains.
Target lock function is inoperative while SOUNDER MODE is active.
It is only operative in case of [Bottom-Scan mode - MODE0] selected.
It is inoperative other than MODE0.
3. TRIGGER SIGNAL
Select which Trigger signal to use.
Use the Cursor Shift key ( or ) to select
“
TRIGGER SIGNAL
”.
Use the Cursor Shift key ( or ) to change the setting.
TRIGGER SIGNAL INTERNAL Use the Cursor Shift key ( or ) to change.
[INTERNAL, EXTERNAL]
INTERNAL: activates the internal trigger signal of KDS-5000BB.
EXTERNAL: activates the signal from an external unit.
(when another echo sounder synchronized)
NOTE!
The sweeping speed might be slower depending on the depth whe the KDS-5000BB is synchronizing with an external echo sounder.
Using the internal trigger signal of KDS-5000BB is recommended for synchronizing with an external echo sounder.
The output terminal for trigger signal has prepared in the unit. Refer to page 98
- 70 -
FUNCTION SETTINGS
4. DEPTH UNIT
The unit of depth measurement can be selected.
Use the Cursor Shift key ( or ) to select
“
DEPTH UNIT
”.
Use the Cursor Shift key ( or ) to change the setting.
DEPTH UNIT m Use the Cursor Shift key ( or ) to change.
[m, ft, fm, br]
5. TEMPERATURE UNIT
The unit of temperature measurement can be selected.
Use the Cursor Shift key ( or ) to select “ TEMP. UNIT ”.
Use the Cursor Shift key ( or ) to change the setting.
TEMPERATURE UNIT °C Use the Cursor Shift key ( or ) to change.
[°C, °F]
6. TEMPERATURE ADJUSTMENT
The water temperature displayed on the screen can be adjusted.
Use the Cursor Shift key ( or ) to select “ TEMP. ADJUST ”.
Use the Cursor Shift key ( or ) to change the setting.
TEMP. ADJUST +0.0°C Use the Cursor Shift key ( or ) to change.
[-9.9°C to +9.9°C , every 0.1 unit ]
+9.9°: maximizes
+0.0°: no adjustment
-9.9°: minimizes
↑
↓
: increases the value.
: decreases the value.
- 71 -
FUNCTION SETTINGS
7. SPEED UNIT
The unit of the ship
’s speed displayed on the screen can be selected when an external navigator connected.
Use the Cursor Shift key ( or ) to select “ SPEED UNIT ”.
Use the Cursor Shift key ( or ) to change the setting.
SPEED UNIT kt Use the Cursor Shift key ( or ) to change.
[kt, km/h] kt: displays the speed in knots.
km/h: displays the speed in km/h.
8. AUTO RETRACT
The Transducer unit can be raised automatically when the ship ’s speed exceeds the speed previously set. The preset speed can be set.
Use the Cursor Shift key ( or ) to select
“
AUTO RETRACT
”.
Use the Cursor Shift key ( or ) to change the setting.
AUTO RETRACT OFF Use the Cursor Shift key ( or ) to change.
[OFF, 10kt (18km/h)] Available setting ranges: 1 to 15kt (1km/h to 27km/h)
Use the Cursor Shift key ( or ) to set the speed after selecting the initial value.
: increases the value.
: decreases the value.
With the speed input the Transducer unit can be raised automatically when the ship
’s speed exceeds a preset speed.
The down arrow appears at the down left corner of the screen when the Transducer unit is being lowered.
When this function is activated, the arrow changes into the up arrow. When the Transducer unit is retracted completely, the sensor lamp on the control panel is turned off.
: Sensor lamp on the Operation unit
Transducer unit status indicator
CAUTION
The ship ’s speed should not exceed 15 knots (27km/h) while retracting the Transducer unit.
The recommended setting speed is less 12kt (22km/h) considering the case that it speeds up without retracting the Transducer unit.
- 72 -
FUNCTION SETTINGS
9. TRAIN CORRECT
This changes the center direction of the detection range into the bow direction (0°).
Select the SONAR MODE and set the desired position by using the Bearing keys
( or ) .
Open “MENU 2” and use the Cursor Shift key
( or ) to select “ OTHERS-TRAIN
CORRECT
”. Press the Cursor Selection (O / +) so that the confirmation sign appears on the screen. Selecting “ OK ” displays the value for adjustment and the displayt of the current center direction is changed into the bow direction (0°). Selecting
“
CANCEL
” cancel the current operation.
TRAIN CORRECT 90° After pressing the Cursor Shift key ( or ), the angle of the center direction set at the menu of SONAR MODE appears.
BOW DIRECTION (0°)
display rotated 90° counterclockwise
To release this function, setting the current bearing at 0° and the procedure
“
TRAIN
CORRECT ” above again are required.
10. PANEL BRIGHTNESS
The backlight brightness of operation panel can be changed.
Use the Cursor Shift key ( or ) to select “ PANEL BIRHGTNESS ”.
Use the Cursor Shift key ( or ) to change the setting.
PANEL BRIGHTNESS 15 Use the Cursor Shift key ( or ) to change.
[0 - 15]
: increases the value and sets brighter.
: decreases the value and sets darker.
- 73 -
FUNCTION SETTINGS
11. POWER SUPPLY FREQUENCY
The switching frequency of the power supply is changed.
The switching currents can cause electrical noise problems.
The noise produced by the SMPS itself can be suppressed changing the frequency.
It is usually not required to change the frequency other than noise problem.
Use the Cursor Shift key ( or ) to select “ POWER FREQUENCY ”.
Use the Cursor Shift key ( or ) to change the setting.
POWER S. FREQUENCY 120k Use the Cursor Shift key ( or ) to change.
[120k, 125k, 130k]
CAUTION
Select “ 120k ” for normal use.
12. TD AUTO DOWN
With the function
“
TD AUTO DOWN ON
” selected, the Transducer unit is automatically lowered when the power turned on.
Use the Cursor Shift key ( or ) to select “ TD AUTO DOWN ”.
Use the Cursor Shift key ( or ) to change the setting.
TD AUTO DOWN OFF Use the Cursor Shift key ( or ) to change.
[OFF, ON]
OFF: This function is inactive. The Transducer unit is not automatically lowered.
ON: This function is active. The Transducer unit is automatically lowered.
NOTE !
It takes time (some seconds) to lower the Transducer unit even if the POWER ON key on the monitor or the key board pressed.
If “TD AUTO DOWN ON ” selected, the Transducer unit starts to lower the Transducer unit just before the unit starts working.
- 74 -
FUNCTION SETTINGS
13. OPERATION MODE MEMORY
The memory of Operation Mode is restricted. Refer to page 94
It can avoid memorizing the operation accidentally by selecting OFF.
Use the Cursor Shift key ( or ) to select “ OPE. MODE MEMORY ”.
Use the Cursor Shift key ( or ) to change the setting.
OPE. MODE MEMORY OFF Use the Cursor Shift key ( or ) to change.
[OFF, ON]
OFF: The new settings for Operation Mode are not overwritten.
ON: The new settings for Operation Mode are overwritten.
- 75 -
FUNCTION SETTINGS
COLOR PALETTE
[MODE KNOB – MENU 2 – COLOR PALETTE]
COLOR PALETTE
COLOR RETURN MARK
Press the Cursor Selection key
O / + to return to MENU 2.
B.G.
1
2
COLOR SEL.
A-1
Use the Cursor Shift key ( or ) to select the desired item to change.
3
4
5
6
7
COLOR
8
INITIAL SETTINGS
EDIT
Use the Cursor Shift key ( or ) to change the settings.
1. COLOR SEL.
The color of echoes and background (A-1, A-2, B-1 or B-2) can be set as desired.
C-1 / C-2 can set the colors freely with Color palette function.
Use the Cursor Shift key ( or ) to select
“
COLOR SEL.
”.
Use the Cursor Shift key ( or ) to change the setting.
COLOR SEL.
A-1 Use the Cursor Shift key ( or ) to change.
[A-1, A-2, B-1, B-2, C-1, C-2]
2. COLOR
The display colors can be select.
C-1 / C-2 can set the colors freely with Color palette function.
Use the Cursor Shift key ( or ) to select
“
COLOR
”.
Use the Cursor Shift key ( or ) to change the setting.
COLOR 8 Use the Cursor Shift key ( or ) to change.
[8, 16]
- 76 -
FUNCTION SETTINGS
HOW TO SET COLOR PALLETTE
Color palette can provide 2 color patterns (C-1 & C-2) freely.
The initial color pattern of C-1 is the same with A-1 and C-2 are is the same with A-2.
Use the Cursor Shift key ( or ) to select
“C-1” or “C-2”, which activates the “
INITIAL
SETTINGS ” and “ EIDT ” functions.
Use the Cursor Shift key ( or ) to select “ INITIAL SETTINGS ” and press the
Cursor
Selection key O / + to back to the
“
INITIAL SETTINGS
”.
Use the Cursor Shift key ( or ) to select
“
EDIT
” and press the Cursor Selection key
O / +. Color palette appears on the screen.
COLOR PALETTE
B.G.
1
2
3
4
5
6
7
COLOR
COLOR
Use the Cursor Shift key ( or ) to select
RETURN MARK the color to set, which activates the RGB ratio
COLOR SEL. function.
A-1
Press the Cursor Selection key O / + to close
8 COLORS this menu.
INITIAL SETTINGS
EDIT Use the Cursor Shift key ( or ) to select
R, G or B for the ratio change .
B.G. Use the Cursor Shift key ( or ) to change
B.G.:background R 4
G 4
B 10 the ratio value (0 to 15).
15 is the strongest in RGB and its tone decreases
in accordance with the smaller number.
Move the Frame to the top after the RGB setting . Press the Cursor Selection key O / + to close this menu and the desired settings are memorized in C-1 or C-2 .
COLOR PALETTE!
Various desired colors can be created from changing
RGB ratio.
RED
Color palette function provides the creation of desired colors. GREEN
WHI TE
BLUE
Utilize this Color palette function to set the most visible display for the reaction of fish schools.
- 77 -
FUNCTION SETTINGS
REMOTE CONTROL SET (OPTION)
Previously set the key each on the remote controller before use.
[MODE KNOB – – REMOTE CONTROL SET]
Refer to page 100 for the settings in details.
- 78 -
FUNCTION SETTINGS
FREQUENCY SETTING
FREQUENCY SETTING
RETURN MARK
TX FREQUENCY 180.0kHz
RX FREQUENCY 180.0kHz
Press the Cursor Selection key O / + to return to MENU 2.
Use the Cursor Shift key ( or ) to select the desired item to change.
Use the Cursor Shift key ( or ) to change the settings.
1. TX FREQUENCY
Adjust the transmitting frequency of the KDS-5000BB and the receiving frequency changes in conjunction with the transmitting frequency.
It can be changed from the basic frequency to ±10kHz every 0.1kHz unit.
Use the Cursor Shift key ( or ) to select “ TX FREQUENCY ”.
Use the Cursor Shift key ( or ) to change the setting.
TX FREQUENCY 180.0kHz Use the Cursor Shift key ( or ) to change.
[BASIC FREQUENCY to ±10kHz]
: decreases every 0.1kHz of the values of the frequencies for TX FREQUENCY and RX
FREQUENCY.
: increases every 0.1kHz of the values of the frequencies for TX FREQUENCY and RX
FREQUENCY.
2. RX FREQUENCY
Adjust the receiving frequency of the KDS-5000BB, but the transmitting frequency does not change in conjunction with the receiving frequency.
It can be changed from the basic frequency to ±10kHz every 0.1kHz unit.
Use the Cursor Shift key ( or ) to select “ RX FREQUENCY ”.
Use the Cursor Shift key ( or ) to change the setting.
RX FEQUENCY 180.0kHz
Use the Cursor Shift key ( or ) to change.
[BASIC FREQUENCY to ±10kHz]
: decreases every 0.1kHz of the values of the frequencies for RX FREQUENCY.
: increases every 0.1kHz of the values of the frequencies for RX FREQUENCY.
- 79 -
FUNCTION SETTINGS
SELF CHECK
The following messages appear on the display.
This function checks the battery voltage, the internal voltage, the hoist up and down or the conditions of the stepping motor in the Transducer unit.
SELF CHECK Use the Cursor Shift key ( or ) to select
“ RETURN MARK ” and press the Cursor
RETURN MARK
NO PROBLEM
SAVE REPORT
Selection key (O / +) to close this menu.
Select
“
SAVE REPORT
” to store the report of Self
Check in the USB memory.
NO PROBLEM : appears when the system has no problem.
MB (Main Board): ABNORMAL POWER SUPPLY VOLTAGE : appears when the abnormal voltage detection of the battery is suspected.
HB (Hull Board): NO RESPONSE: appears when the disconnection of the wiring between Hull Unit and the communication line is suspected.
TRANSDUCER UNIT: BLOWN FUSE: appears when the blown fuse in the hoist is suspected.
TRANSDUCER UNIT: UP (DOWN) LIMIT NOT DETECTED: appears when the abnormal upper (down) limit switch is suspected.
TRAIN MOTOR: DISCONNECTION appears when the abnormal train motor is suspected.
TILT MOTOR: DISCONNECTION appears when the abnormal tilt motor is suspected.
TRAIN MOTOR: ABNORMAL DETECTION OF ORIGIN appears when the abnormal train motor or the abnormal detection of training position inside the Transducer unit is suspected.
TRAIN MOTOR: STEP OUT appears when the abnormal train motor or the abnormal detection of training position inside the Transducer unit is suspected.
NOTE!
Both TRAIN MOTOR: ABNORMAL DETECTION OF ORIGIN and TRAIN MOTOR: STEP OUT appear when the Hall IC board in the Transducer unit is abnormal.
TRAIN MOTOR: DISCONNECTION, TRAIN MOTOR: ABNORMAL DETECTION OF ORIGIN and
TRAIN MOTOR: STEP OUT appear all when the Transducer unit is total breakdown.
- 80 -
FUNCTION SETTINGS
MAINTENANCE
[MODE KNOB – – MAINTENANCE]
MAINTENANCE
RETURN MARK
LANGUAGE ENGLISH (en)
TIME
ELAPSED TIME
UPDATE
2013-06-05 17:36:22
24H
(O / +) to return to MENU 2.
Press the Cursor Selection key
Use the Cursor Shift key ( or )
BACKUP
RECOVERY
VERSION
KDS-5000BB to select the desired item to change.
Each menu appears after the Cursor
Selection key
(
O / +) pressed .
LANGUAGE
Use the Cursor Shift key ( or ) to select
“
LANGUAGE
”.
Use the Cursor Shift key ( or ) to to select the desired language.
It is required to turn the power off once to determine the language.
Hold the OFF key for a while and then turn the ON key.
ELAPSED TIME
It indicates the total time that elapses while the KDS-5000BB operating and can be reset.
Use the Cursor Shift key ( or ) to select “ ELAPSED TIME ”.
The following menu appears on the bottom of the screen after pressing the Cursor Selection key (O / +).
ELAPSED TIME RESET
? Do you reset elapsed time?
OK CANCEL
CANCEL: Use the Cursor Shift key ( or ) to to select “ CANCEL ” and press the Cursor
Selection key (O / +) to finish this menu.
OK: Use the Cursor Shift key ( or ) to select “ OK ” and press the Cursor Selection key
(O / +) to reset the elapsed time. 0H appears on the screen.
1. UPDATE
This is the way to update the version of the program.
Use the Cursor Shift key ( or ) to select “ UPDATE ”.
The following menu appears on the bottom of the screen after pressing the Cursor Selection key (O / +). Use the Cursor Shift key ( or ) to select
UPDATE
! Insert the USB stick contains updated files Use the Cursor Shift key ( or ) to
select “CANCEL” and press the Cursor
NEXT CANCEL Selection key (O / +) to close this menu.
<To be continued>
- 81 -
FUNCTION SETTINGS
[HOW TO UPDATE VERSION]
Insert the USB stick contains the upgraded files.
Use the Cursor Shift key ( or ) to select
“
NEXT
”.
Pressing the Cursor Selection key O / + updates the program.
After rebooting the unit, it is operated with the updated version .
2. BACKUP
This is the way to back up the settings.
Use the Cursor Shift key ( or ) to select “ BACKUP ”.
The following menu appears on the bottom of the screen after pressing the Cursor Selection key (O / +). Use the Cursor Shift key ( or ) to select.
BACKUP
? Where to back up?
Use the Cursor Shift key ( or )
! Plug in Memory stick now in case of USB to select “CANCEL” and press the Cursor work. Selection key (O / +) to close this menu.
INTERNAL MEMORY USB
CANCEL
[HOW TO BACK UP THE SETTINGS]
Use the Cursor Shift key ( or ) to select where to back up ( INTERNAL or MEMORY
USB ) and press the Cursor Selection key (O / +) to backup the settings.
3. RECOVERY
This is the way to recover the settings.
Use the Cursor Shift key ( or ) to select “ RECOVERY ”.
The following menu appears on the screen after pressing the Cursor Selection key
(O / +). Use the Cursor Shift key ( or ) to select.
RECOVERY
? Which item do you store?
Use the Cursor Shift key ( or )
! Plug in Memory stick now in case of USB to select “ CANCEL ” and press the Cursor work. Selection key (O / +) to close this menu.
INTERNAL MEMORY USB
FACTORY SETTTINGS CANCEL
[HOW TO RECOVER THE SETTINGS]
Use the Cursor Shift key ( or ) to select what to recover ( INTERNAL, MEMORY USB or
FACTORY SETTINGS) and press the Cursor Selection key (O / +) to recover the settings.
Selecting the factory settings will back to the factory settings.
4. VERSION
Use the Cursor Shift key ( or ) to select
“
VERSION
” to know the version of the program in this unit.
- 82 -
CHAPTER 5
DESCRIPTIONS of
KNOBS and KEYS
This Chapter explains how to use the knobs and keys.
Knobs
Keys
Mode Knob
Range Knob
Sector Knob
Gain Knob
Far Gain Knob
Power ON/OFF Key
Hoist/Lower Key
Sensor Lamp
Bearing Key
Tilt Key
Cursor key
Target Lock Key
Mark Key
Coloe rejection Key
Operation Mode Key
87
87
88
89
86
86
87
84
84
85
90
92
92
92
94
- 83 -
KNOBS
MODE KNOB
The display mode is selected.
The Sub-Display menu displayed in the right split screen can be set via
“ ”.
Refer to page 58
The own ship
’s position in the Off-Center Mode can be set via “ ”.
Refer to page 64
RANGE KNOB
The basic ranges can be changed.
8 ranges can be set via “ ”. Refer to page 48
The unit of range measurement can be selected via
“ ”. Refer to page 71
The display (ON/OFF) of Scale dots can be selected via “ ”. Refer to page 64
Display of the Range in selected unit
RANGE
BEARING
SECTOR
TILT
MARKER
CURSOR
Changes this distance
SCALE DOTS
- 84 -
KNOBS
SECTROR KNOB
The horizontal training angle can be changed when SONAR MODE selected.
The vertical training angle can be changed when BOTTOM-SCAN MODE selected.
[SONAR MODE] [BOTTOM-SCAN MODE]
Displays the selected sector angle
CURSOR
MARKER
RANGE
BEARI NG
SECTOR
TI LT ANGLE
Changes this angle
Changes this angle.
Clockwise rotation ( ) increases the sector width and counterclockwise rotation ( ) decreases it . The desired step can be selected via
“ ”. Refer to page 63
SONAR MODE
5° STEP 5° 25° 45° 85° 125° 165° 205° 360°
10° STEP 10° 30° 50° 90° 130° 170° 210° 360°
15° STEP 15° 45° 75° 105° 135° 165° 225° 360°
BOTTOM-SCAN MODE
3° STEP 3° 27° 45° 63° 93° 117° 147° 177°
5° STEP 5° 25° 45° 65° 95° 115° 145° 175°
- 85 -
KNOBS
GAIN KNOB
Rotating this knob clockwise can adjust or increase the sensitivity of the sonar display.
The gain value can be set via
“
MENU 2
–
GAIN UP
”. Refer to page 52
FAR GAIN KNOB
Rotating this knob clockwise increases sensitivity of the sonar for the last half of the displayed range and adjusts the TVG curve.
Refer to page 53
- 86 -
KEYS
POWER ON/OFF KEYS
ON key
Press this key to turn on the power. The Transducer unit is automatically lowered.
The sensor lamp on the Operation unit lights while the Transducer unit is being lowered.
The sign “
Please wait
” appears on the bottom of the screen. The sonar operation starts after the sign disappears.
OFF key
Press this key to turn off the power. The Transducer unit is automatically raised.
The sign “ Please wait ” appears on the bottom of the screen. The power is turned off after the sign disappears.
The sensor lamp ( ) is off after the Transducer unit is retracted into the TD tank.
Do not turn off the power on the Hull unit until the sensor lamp is off.
HOIST/LOWER KEYS
↑ : HOIST KEY / ↓ : LOWER KEY
The Hoist and Lower keys raises and lowers the Transducer unit while operating the
KDS-5000BB.
Pressing the Hoist key raises the Transducer unit and the mark on the lower left screen changes into the up arrow ( ↑ ) . The sensor lamp is off after the retraction of the Transducer unit is completed.
Pressing the Lower key lowers the Transducer unit, the mark changes into the down arrow (
↓
) and the sensor lamp lights.
Down the ship ’s speed and press the Lower key in case the Transducer unit is retracted by the function
“AUTO RETRACT”.
NOTE!
[ X ] in red appears on the left corner of the screen in case of the malfunction of hoisting/lowering of the Transducer unit.
SENSOR LAMP
The sensor lamp lights while the Transducer unit is being lowered.
Do not turn off the power on the Hull unit until the sensor lamp is off.
SENSOR LAMP
The sensor lamp lights while the Transducer unit is in this range.
- 87 -
KEYS
BEARING KEY
[SONAR MODE]
The center direction of the detection range can be shifted as follows.
5° step shift
Displays values of Sector angle
Shifts the center Shifts the center counterclockwise clockwise
RANGE
SECTOR
TI LT ANGLE
MARKER
This key changes
CURSOR the center direction
This arrow mark shows the center direction.
[BOTTOM-SCAN MODE]
The direction of the detection range can be shifted.
5° step shift
This key changes This key changes
scanning direction scanning direction
counterclockwise clockwise
Display of scanning direction
Displays the scanning
direction of the bow.
Displays the direction
of the bow every 90 ° .
[SOUNDER MODE]
The direction of the detection range can be shifted together with
“TILT KEY”.
The shifted angle is the same with BOTTOM-SCAN MODE.
Refer to page 90
- 88 -
TILT KEY
[SONAR MODE]
The tilt angle can be changed.
5゜
0゜
Changes this angle.
KEYS
RANGE
BEARING
SECTOR
TILT
TILT
Shifts downward. Displays the Tilt angle.
-90゜
Variable Tilt angle: in increments of 1° from -5° ( 0°) to -90°
[BOTTOM-SCAN MODE]
The scanning center can be shifted.
This key changes the scanning center and the Tilt angle.
TILT Shifts clockwise
Shifts counterclockwise
Depth beneath Own ship Beneath Own ship ( -90°)
Displays the angle and
the center of direction.
Center is Set in the arrow range. Set in the arrow range.
beneath Own ship.
Own ship’s Own ship’s Own ship’s
position position position
in center shifted shifted
rightward leftward
Variable Tilt angle (Refer to the page 63 for the setting of step.)
3° step: in increments of 3° from –3° to –90°
5° step: in increments of 5° from –5° to –90°
<to be continued>
- 89 -
KEYS
[SOUNDER MODE]
The direction of emitting the sound wave and the bearing of the detection can be shifted together with
“BEARING KEY”.
Indicator Indicator
Tilt angle Bearing angle
Use the Tilt key to set this angle.
BEARING
Displays of the tilt angle
TILT
MARKER
Use the Bearing key to
set the direction of the
CURSOR
detection.
No depth display other than the tilt angle
–90°(beneath own ship) selected.
Variable Tilt angle: in increments of 1° from –5° (0°) to –90°
Use the Depth marker to measure the depth other than the tilt angle
–90°.
CURSOR KEY
Use 2 types (one type in case of SOUNDER MODE) of Cursor to display the range from own ship to the cursor location.
Use the Cursor selection key to select the cursor.
Use the Cursor shift keys to move the cursor.
O / + key [SONAR MODE] Ring marker and Cross cursor ON/OFF available
[BOTTOM-SCAN MODE] Depth scale and Cross cursor ON/OFF available
[SOUNDER MODE] Depth scale ON/OFF available key Ring marker enlarged, Cross cursor shifted upward,
Depth scale shifted to the shallower range key Ring marker reduced, Cross cursor shifted downward,
Depth scale shifted to the deeper range key Cross cursor shifted leftward key Cross cursor shifted rightward
<to be continued>
- 90 -
KEYS
[when the power turned on]
No cursors appear on the screen when the power turned on. Press the Cursor selection key (O / +) to activate the function.
Press the Cursor shift keys ( or ) to display the Marker.
Press the Cursor selection key again to activate this function.
(In case of SOUNDER MODE, this function is off.)
Inactive functions are displayed in yellow.
The Marker and the Cursor disappear after pressing the Cursor selection key again.
[when the Marker selected] (Cross cursor displayed in yellow or no display)
SONAR MODE
Horizontal distance (a)
MARKER Slant distance (b) This key sets
Depth (c) the marker distance shorter.
RANGE
BEARING
SECTOR
TILT
MARKER
This key cursor
CURSOR
sets the marker
distance longer. a b c a
Changes this distance
BOTTOM SCAN MODE SOUNDER MODE
RANGE
BEARING
Shifts the Marker Horizontal distance
TILT
MARKER upward. MARKER Slant distance
MARKER
30.5
CURSOR
Shifts the Marker
downward.
MARKER DEPTH (DEPTH SCALE) MARKER DEPTH (SLANT DISTANCE)
*Marker data displays in the submenu.
<To be continued>
- 91 -
KEYS
[when the Cross cursor selected] (Marker displayed in yellow or no display)
In case of SOUNDER MODE this function is inactive.
Use the Cursor shift keys to place the cursor where desired.
The data of the
“Cross Cursor” is displayed in the submenu.
SONAR MODE BOTTOM-SCAN MODE
RANGE RANGE
BEARING
BEARING
: Bearing : Bearing
SECTOR
TILT
TILT
: H.distance : H.distance
MARKER
MARKER
+
: S.distance : S.distance
CURSOR
CURSOR
: Depth :Depth
This Cross cursor is also used for placing the event mark (Refer to page 93) and target mark
(Refer to page 80).
TARGET LOCK KEY ( )
The following Target lock key actions are available in the SONAR MODE and in the
BOTTOM-SCAN MODE – MODE 0 only and it is different action depending on the selected menu via
“MENU 2 – TARGET LOCK.
-Setting MODE 0: the train direction is reversed.
-Setting MODE 1 & 2: it tracks the target automatically.
-Setting MODE 3 (an external navigator should be connected):
Place the Cross cursor on the target and press the Target lock key.
A target mark is inscribed at the Cross cursor location and tracks the target automatically. Refer to the page 69 “
TARGET LOCK
” for details.
NOTE!
This Target lock key is not available other than the above Modes.
- 92 -
KEYS
MARK KEY ( )
The Mark key functions to mark desired locations on the screen, and 5 marks can be inscribed at the Cross cursor locations desired.
Move the Cross cursor to the desired locations and press the Mark key.
The Mark ( ) appears at the Cross cursor location and moves with ship ’s movement.
RANGE
BEARING
SECTOR
TILT
This mark also appears on the screen when the sub-display, WAKE display is active.
+
MARKER
CURSOR
MARK
COLOR REJECTION KEY (
)
This key can eliminate the appearance of unwanted week colors.
It can eliminate small fish and unidentified objects and display the clearer images.
Each time this key is pressed, one of the weakest display colors is eliminated.
RANGE
BEARING
SECTOR
TILT
RANGE
BEARING
SECTOR
TILT
RANGE
BEARING
SECTOR
TILT
RANGE
BEARING
SECTOR
TILT
RANGE
BEARING
SECTOR
TILT
RANGE
BEARING
SECTOR
TILT
Color scale
MARKER
MARKER MARKER
MARKER
MARKER
MARKER
+
CURSOR
CURSOR
CURSOR CURSOR
CURSOR CURSOR
7 colors 6 colors 5 colors 4 colors 3 colors 2 colors
- 93 -
KEYS
OPERATION MODE KEY
3 different types of customized operation settings can be registered previously.
Press one of the Operation mode keys to operate the units with the desired settings soon after pressing it.
Open MENU 2 display and press one of the Operation mode keys.
The following “OPERATION MODE” menu appears on the screen.
Use the Cursor Shift key ( or ) to highlight the item to change.
Use the Cursor Shift key ( or ) to change the setting values.
OPERATION MODE 1 (2, or 3)
SET VALUE
SET VALUE
Each time the Cursor shift key ( or )
Pressed, the value changes
DISPLAY MODE
RANGE
STEP
SECTOR
BEARING
TILT
GAIN UP
TVG CURVE
SET VALUE
SET VALUE
SET VALUE
SET VALUE
SET VALUE
SET VALUE
Use the Mode knob to back to the desired mode after the settings completed.
Press one of the desired keys (1, 2 or 3) to activate the memorized operation menu.
Even if the settings are changed via MENU 2 or Operation unit, the settings in the Operation mode (1, 2 or 3) remain.
In case the settings are changed via MENU 2 or Operation unit while the Operation mode is used, the action will follow the changed settings, but it back to the Operation mode by pressing one of the Operation mode keys again.
NOTE!
This is the way to register the Operation mode being used without opening the
“OPERATION MODE” menu.
Hold one of the operation mode keys (1, 2 or 3) for 3 seconds after the first buzzer.
The desired setting is registered in the selected Operation mode key after the buzzer sounds again.
Do not release the key until the second buzzer sounds.
Otherwise the new settings cannot be registered.
Selecting [MODE KNOB - – OTHERS – OPE.MODE MEMORY OFF] can protect overwriting the new settings of the operation.
Refer to page 75
- 94 -
CHAPTER 6
OPTION
This chaper provides you the explanation related to the optional input/output terminals and the remote controller.
Option Option List
Input/Output Terminals
Input/Output Terminals (Processor unit)
Remote Controller
96
98
99
100
- 95 -
OPTION
OPTION LIST
For Processor unit
P. No.
ESR-1809-SET
Description
Remote Controller Set
OP-360
OP-190
XGA Connect Cable Assy
Trigger Output Cable 36981D
(one side of the cable is chopped)
With 4m cable and cable for connecting remote controller with OP-287 connecter.
Terminal for XGA Output
(to connect an external monitor)
To connect Trigger Output to the
Sounders of other companies
(5m)
For DHU-530
P. No.
OP-700
ESR-1506
30927C-2
30927C-3
ESR-1507
FRP TD tank set
ESR-1504
ESR-160 32679C-2
ESR-160 32679C-3
DJB-540
Description
Junction Box Mounting Kit
PVC, 1230mm / 9.0kg
(For 1411mm of TD shaft)
PVC, 1500mm / 11.0kg
(For 1681mm of TD shaft)
PVC,1800mm / 13.0kg
(For 1981mm of TD shaft)
FRP,1500mm / 12.0kg
(Including Shaft guide)
(ESR-1507x1,
ESR-1511x2)
ESR-1510x2,
1411mm
1681mm
TD shaft
1981mm
For mounting Junction Box on the
Hull Unit
Hull Unit
Junction Box
Junction Box Mounting Kit
TD tank
- 96 -
P. No.
ESR-1510
ESR-1511
G-100
Bath cork
Grease
Description
Shaft guides
Shaft guides with adjuster
OPTION
- 97 -
OPTION
INPUT/OUTPUT TERMINALS
The following optional terminals are required to connect a remote controller and an External monitor.
This is to indicate the settings for the interface setups.
Note that the connection cables between the KDS-5000BB and the external units to be connected are not supplied as standard.
P. No.
OP-360
STANDARD
SUPPLY
STANDARD
SUPPLY
STANDARD
SUPPLY
STANDARD
SUPPLY
STANDARD
SUPPLY
STANDARD
SUPPLY
NAMES of TERMINALS
VGA OUTPUT
(TERMINAL for
EXTERNAL MONITOR)
TERMINAL CONNECTIONS
No1: RED OUTPUT No7: GREEN GND
No2: GREEN OUTPUT
No3: BLUE OUTPUT
No8: BLUE GND
No10: GND
No5: GND
No6: RED GND
No1: ALARM
No2: ALARM
No13: H-SYNC
No14: V-SYNC
OTHER Nos: NC
*not used currently
*normally open contact
ALARM
(TERMINAL for
EXTERNAL BUZZER)
TRIG - OUT
(TERMINAL for
TRIGGER OUTPUT)
NAV - IN
(TERMINAL for
NAVIGATOR)
No1: TRIGGER
OUTPUT+
No2: SHIELD
No1: SIGNAL INPUT+
No2: SIGNAL INPUT-
No3: SHIELD
No3: TRIGER OUTPUT-
No4: SIGNAL OUTPUT+
No5: SIGNAL OUTPUT-
NMEA - OUT
(TERMINAL for
NAVIGATOR or
Something else)
SERIAL - IF
(TERMINAL for
EXTERNAL SOUNDER)
No1: SIGNAL INPUT+
No2: SIGNAL INPUT-
No3: SHIELD
No1: SIGNAL INPUT+
No2: SIGNAL INPUT-
No3: SHIELD
No4: SIGNAL OUTPUT+
No5: SIGNAL OUTPUT-
No6: NC
No5: SIGNAL OUTPUT-
No6: NC
No7: NC
TRIG - IN
(TERMINAL for
TRIGGER INPUT)
No4: SIGNAL OUTPUT+
No1: TRIGGER INPUT No5: GND
No2: NC
No3: NC
No6: NC
No7: NC
No4: NC No8: SHIELD
* Note that nothing should be connected to the above NC.
A navigator can be connected to NMEA-OUT terminal (No.1 and No.2), but the data of
NAV-IN terminal will prior to NMEA-OUT terminal (No.1 and No.2).
- 98 -
OPTION
INPUT/OUTPUT TERMINALS (PROCESSOR UNIT)
Remove all cables connected to the Processor unit before mounting any terminals.
1) Remove 4 Binding Screws holding the Lid of the Processor unit and remove the Lid
(Drawing A position).
Remote ControllerTerminal
DANGER
A
VGA Terminal Do not open the Case Cover thoughtlessly.
There might be some high voltage potion inside the unit which sometimes causes death or injury.
Only qualified personnel should work on mounting
2) Remove the Blind Lid or the Cap to mount the terminal.
Mount it referring to the above drawing. terminals.
3) Insert the connector of the terminal into the specified terminal of the Main Board or the
External Connecting Board.
-VGA OUTPUT Terminal
→ J3 or J4 on the Main Board No.792
-REMOTE CONTROLLER TERMINAL → J3 on the External Connecting board No.796
4) Put the Lid of the MBB back to its original place after finishing the mounting work.
Main Board No.792 External Connecting Board No.796
J3
J4
J3
- 99 -
OPTION
REMOTE CONTROLLER
Connect the terminal of the Remote Controller to the specified port .
Hoist Key raises the Transducer unit.
Lower Key lowers the Transducer unit.
Mark Key enters the Mark.
Bearing Key changes the center direction right or left.
Tilt Key adjusts the Tilt Angle.
Target Lock Key reverses the sector rotary direction or the track the reaction automatically.
[MODE KNOB – – REMOTE CONTROL]
1) Select the Mode Knob ( )
2) Use the Cursor Shift key ( or ) to select
“
REMOTE CONTROL
” and press the
Cursor Selection key (O / +) so that the following menu appears on the screen.
REMOTE CONTROL (Initial Settings)
RETURN MARK
1 BEARING LEFT
2 BEARING RIGHT
3 TRANSDUCER UNIT UP
4 TILT UP
5 TRANSDUCER UNIT DOWN
6 TILT DOWN
7 MARK
8 TARGET
Use the Cursor Shift key ( or ) to select the key number to be changed.
The number shows the key number of the Remote Controller.
Each time the Cursor Shift key ( or ) pressed, the item appears in the following orders
[OPE. MODE 1, OPE. MODE 2, OPE.MODE3, TARGET, MARK, COLOR REJECTION, CURSOR SEL,
CURSOR UP, CURSOR DOWN, CURSOR RIGHT, CURSOR LEFT, RANGE SHALLOW, RANGE DEEP,
TRANSDUCER UNIT UP, TRANSDUCER UNIT DOWN, TILT UP, TILT DOWN, BEARING RIGHT, BEARING
LEFT, OPE.MODE 1 ……….]
All ranges of the range setting menu can be controlled by the remote control keys unitl the
Range Knob operated.
- 100 -
ADDITIONS
DISPOSAL
WARNING
The KDS-5000BB contains the lithium battery of high-density energy.
Careless disposal of the lithium battery causes electric shorts, impact, heat, electrical shock, explosion, injury, fire and so on.
DISPOSAL OF KDS-5000BB
Dispose of the KDS-5000BB in accordance with local regulations.
DISPOSAL OF LITHIUM BATTERY
Place a piece of adhesive tape across the plus and minus terminals before disposing of the llithium battery. Dispose of the lithium battery in accordance with local regulations.
- 101 -
ADDITIONS
SPECIFICATIONS
Model
Item
Processor unit
Operation unit
Hull unit
Output power (RMS)
Output frequency
Tilt angle
Beam angle
TD stroke
Display size and type
Display resolution
Basic ranges
Range units
Scanning sector angles
360º Scanning time
(extracts)
Bearing center
Presentation modes
Data display
Off-Center
Target lock
Presentation colors
Functions
Language
External Input
External Output
NMEA ports
Power supply
Power consumption
Operating temperature
Water protection
Sonar mode
Bottom scan mode
Scanning range (m)
Scanning time (sec.) 5º step
Scanning time (sec.) 10º step
Scanning time (sec.) 15º step
Scanning time (sec.) 20º step
Processor unit
Hull unit
Processor unit
Hull unit
Content
KDS-5000BB
DPU-510
DOU-520
DHU-530
1.5kW
180kHz
+5° to -90 ° (1°step)
10°
180 to 380 mm (Recommended value 180 mm)
Any monitor with XGA resolution (Owner supplied)
1024 x 768 ( XGA )
8 ranges freely set m, ft, fm, br
5°step: 5°, 25°, 45°, 85°, 125°, 165°, 205°, 360°
10°step: 10°, 30°, 50°, 90°, 130°, 170°, 210°,360°
15°step: 15°,45°,75°,105°,135°,165°,225°,360°
20°step: 20°,60°,100°,140°,180°,220°,260°,360°
3°step: 3°, 27°, 45°, 63°, 93°, 117°, 147°, 177°
5°step: 5°, 25°, 45°, 65°, 95°, 115°, 145°, 175°
20
5.7
40
7.6
60 80 100 120 160 180 200 240 400
9.5
11.4
13.3
15.3
19.1
21.0
23.0
26.8
42.2
4.1
3.5
5.0
4.1
6.0
4.8
7.0
5.4
8.0
6.1
8.9
10.8
11.8
12.7
14.7
22.3
6.7
8.0
8.6
9.3
10.6
15.7
3.2
3.7
4.2
every 5°step selectable
4.6
5.1
5.6
6.6
7.1
7.5
8.5
12.3
Sonar mode + Data display, Off-center mode + Data display
Off-center on the whole screen, Bottom scan mode + Data display,Sounder Mode + Data display
Secter center angle, Tilt angle, Tilt angle indicator, Ring marker, Cross Cursor
Compass (option), Navigation (option)
Fore, Back, Left, Right
Reverse, Horizontal, Horizontal + Vertical, Marker + Horizontal
8/16 colors
Operation mode (3 modes), Off-center (4 changes), Train correct, Power rejection
Gain adjust, Temperature adjust, Pulse width control, TVG change, Target lock
Color change (4 types + 2 types of color palette settings), Dynamic range
Interference rejection, Color rejection, Filter (OFF/1/2), Gain control, Far gain control
External trigger synchronization, Trigger signal output
Hoist sensor lamp, Audio (optional speaker required), Stabilizer (up to 25°controllable)
Transducer unit automatic retract (Navigator connect required), Full-screen gain control
English, Japanese
Trigger input, Navigator input, External sounder input, Remote controller input
External buzzer, Trigger output, NMEA output, XGA output, Audio output
USB terminal (memory for setting values)
Total1: input / output
21.6 to 31.2 VDC
21.6 to 31.2 VDC
70 W or less (24 VDC)
70 W or less (24 VDC)
-15 °C to + 55 °C
-