Table of Contents
1. Introduction .....................................................................................4
1.1 Key Features ...............................................................................4
1.2 Indications for Use ......................................................................4
1.3 Explanation of Symbols ...........................................................5-6
2. Warnings and Cautions ...............................................................6-8
3. Components ....................................................................................9
4. Cleaning ........................................................................................10
4.1 Before using your pump ............................................................10
4.2 After using your pump ...............................................................10
5. Assembly .........................................................................................11
6. Pumping .........................................................................................12
6.1 Positioning ................................................................................12
6.2 Button Controls .........................................................................13
6.3 LCD Screen ...............................................................................13
6.4 Battery Information......................................................................14
6.5 Pump Operation ...................................................................15-16
6.6 Suction Settings .........................................................................17
6.7 Massage and Expression Modes ..............................................17
7. Breast Shield Sizing ......................................................................18
7.1 Understanding Size ...................................................................18
7.2 Test your breast shield size ..................................................18-19
7.3 Determining the right fit .............................................................19
8. Breast Milk Storage ......................................................................19
8.1 How long can I store breast milk? ..............................................19
8.2 How do I thaw and use stored milk? ..........................................20
9. Troubleshooting ............................................................................21
10. Disposal .........................................................................................22
11. Technical Information ...................................................................22
12. Electromagnetic Compatibility ................................................23-26
13. Description of IP Classification ....................................................27
14. Warranty ....................................................................................28-29
3
3. Components
• Cimilre reserves the right to substitute any component or accessory with a replacement
of equivalent performance.
9
4
5
10
3
2
11
6
7
12
1
14
15
8
13
Included Components
1 - Dual-Motor Rechargeable Breast Pump, Cimilre S5 Plus
2 - Tubing
3 - Backflow Protector Top
4 - Backflow Protector Silicone
5 - Backflow Protector Bottom
2x Milk
Collection Kit
6 - 24mm & 28mm Breast Shield
7 - Valve
8 - Bottle
9 - Bottle Cap
10 - Nipple
11 - Bottle Cover
12 - Bottle Disk
13 - Air Flow Port
14 - USB-C Cable
15 - Adapter - DC5V, 2A
9
6.2 Button Controls
Adjust
Suction (Vacuum) Level
Sync Button
SELECT
Button
(Pump 1 and 2
operate at the same
suction level)
(Select pumps 1 and
2 individually)
PUMP 1 Button
PUMP 2 Button
(Pause and restart
pump 1)
(Pause and restart pump 2)
Power Button
6.3 LCD Screen
Battery Status
Sync Mode
Expression Mode
Suction (Vacuum) Level
Massage Mode (Massage mode symbol
turns off when using expression mode.)
Timer Display
13
6.5 Pump Operation
When the pump is powered on for the first time after unboxing, the suction
may be preset to a higher level than desired. Adjust the level to a preferred
setting before first use. After first use, the Cimilre S5 Plus will automatically
remember your last settings for your next pumping session.
1. Wash hands before touching breast pump and parts.
2. Connect the tubing to each air flow port.
3. To begin pumping, press and hold the power button
on top of the pump motor. The device will power ON,
indicated by the screen lighting up and will be in
SYNC mode.
4. If you are single pumping, press the play/pause button
to pause the motor for the breast you will not be pumping.
5. To adjust suction (vacuum) strength while in
SYNC Mode, use the
level buttons to select
preferred suction strength/ level.
(Levels 1-5 (Massage Mode) /
Levels 6-12 (Expression Mode)
15
6. To adjust the suction (vacuum) strength for each breast
independently, press SYNC button to power SYNC off
(“SYNC” light in center of screen will turn off and Pump
1 will begin to flash).
7. Press the “SELECT” button to choose which pump
to adjust (“Pump 1” or “Pump 2” will flash when chosen).
Then use the
level buttons to select preferred suction
strength/level. Press “SELECT” again to adjust the
suction strength/level on the other side.
8. At any time, press the play/pause button for pump
1 or 2 to pause and start pump operation.
9. To return to using the same suction level for both sides,
press the "SYNC" button. The SYNC light will appear in
center of screen, and the suction level will default to the
lowest suction level set between the two pumps.
10. When you wish to stop expressing, press the Power
button and then remove the milk collection kit from
your breast.
16
11. Close the bottle(s) tightly with bottle disk and cover,
and store safely.
6.6 Suction Settings
1. The Cimilre S5 Plus will automatically remember your last settings for your
next pumping session. If you want to start pumping on different settings,
adjust the settings before you start expressing.
2. The suction (vacuum) level refers to the suction strength; this is measured
in millimeters of mercury (mmHg). When you are using the Cimilre S5 Plus,
you will usually find that expressing is most effective on the highest suction
level that is comfortable for you.
However, it’s important not to set suction level so high that it makes you
uncomfortable or causes pain as this can hinder your milk flow.
!
While some discomfort may be felt when first using a breast pump, using a breast pump
should not cause pain. If you are feeling strong discomfort or pain while using the breast
pump or unsure about breast flange sizing, immediatley stop use and contact a healthcare
professional.
6.7 Massage and Expression Modes
Massage Mode: Suction pattern with fast cycle speed and low suction to
help encourage a letdown and to start milk flowing.
Expression Mode: Suction pattern with slower cycle speed and higher
suction to express milk gently and efficiently.
17
10. Disposal
As an electrical and electronic equipment, the device must be
disposed of according to a specialized procedure for collection,
pick-up and recycling or destruction in accordance with Directive
2012/19/EU of the European Council on Waste Electrical and
Electronic Equipment [WEEE]. Please properly dispose the
Class II medical device in accordance with local, state and federal
regulations.
11. Technical Information
Contents
Rated voltage and frequency
Description
Input: DC 5V, 2A
Power consumption
0.4 A
Battery / Life
3.7V 2300mAh Li-Polymer / 2 hours +
Protection on electronic shock
Class II,
Degree of protection against ingress of water
IP Classification: IP22
TYPE BF Applied Part
Operation mode (Continuous operation) Expression, Massage, Sync Mode
Suction levels
Cycle speeds
Single/Double
Expression Mode
6 - 12 Levels
Massage Mode
1 - 5 Levels
Expression Mode
Fixed (24-35)
Massage Mode
Fixed (52-93)
Single/Double
Timer function
Automatic Off ( 30 min ± 1 min)
Noise
Less than 45 dB
Backflow protection
Yes
Cleaning Method for Accessories
Boiling water
Operating conditions
Ambient temperature
41 to 104°F
Relative humidity
20 to 80 %
Air pressure
700 to 1,060 hPa
80
40
106
5
20
Temperature
70
Humidity
Pressure
Transport and storage conditions
22
Ambient temperature
-4 to 122°F
Relative humidity
20 to 95 %
Air pressure
500 to 1,060 hPa
95
50
106
-20
20
Temperature
Humidity
50
Pressure
REV 0.2
2022.03.04
QF-708-22
UM-115(0.2)