advertisement
▼
Scroll to page 2
of
29
Table of Contents 1. Introduction .....................................................................................4 1.1 Key Features ...............................................................................4 1.2 Indications for Use ......................................................................4 1.3 Explanation of Symbols ...........................................................5-6 2. Warnings and Cautions ...............................................................6-8 3. Components ....................................................................................9 4. Cleaning ........................................................................................10 4.1 Before using your pump ............................................................10 4.2 After using your pump ...............................................................10 5. Assembly .........................................................................................11 6. Pumping .........................................................................................12 6.1 Positioning ................................................................................12 6.2 Button Controls .........................................................................13 6.3 LCD Screen ...............................................................................13 6.4 Battery Information......................................................................14 6.5 Pump Operation ...................................................................15-16 6.6 Suction Settings .........................................................................17 6.7 Massage and Expression Modes ..............................................17 7. Breast Shield Sizing ......................................................................18 7.1 Understanding Size ...................................................................18 7.2 Test your breast shield size ..................................................18-19 7.3 Determining the right fit .............................................................19 8. Breast Milk Storage ......................................................................19 8.1 How long can I store breast milk? ..............................................19 8.2 How do I thaw and use stored milk? ..........................................20 9. Troubleshooting ............................................................................21 10. Disposal .........................................................................................22 11. Technical Information ...................................................................22 12. Electromagnetic Compatibility ................................................23-26 13. Description of IP Classification ....................................................27 14. Warranty ....................................................................................28-29 3 3. Components • Cimilre reserves the right to substitute any component or accessory with a replacement of equivalent performance. 9 4 5 10 3 2 11 6 7 12 1 14 15 8 13 Included Components 1 - Dual-Motor Rechargeable Breast Pump, Cimilre S5 Plus 2 - Tubing 3 - Backflow Protector Top 4 - Backflow Protector Silicone 5 - Backflow Protector Bottom 2x Milk Collection Kit 6 - 24mm & 28mm Breast Shield 7 - Valve 8 - Bottle 9 - Bottle Cap 10 - Nipple 11 - Bottle Cover 12 - Bottle Disk 13 - Air Flow Port 14 - USB-C Cable 15 - Adapter - DC5V, 2A 9 6.2 Button Controls Adjust Suction (Vacuum) Level Sync Button SELECT Button (Pump 1 and 2 operate at the same suction level) (Select pumps 1 and 2 individually) PUMP 1 Button PUMP 2 Button (Pause and restart pump 1) (Pause and restart pump 2) Power Button 6.3 LCD Screen Battery Status Sync Mode Expression Mode Suction (Vacuum) Level Massage Mode (Massage mode symbol turns off when using expression mode.) Timer Display 13 6.5 Pump Operation When the pump is powered on for the first time after unboxing, the suction may be preset to a higher level than desired. Adjust the level to a preferred setting before first use. After first use, the Cimilre S5 Plus will automatically remember your last settings for your next pumping session. 1. Wash hands before touching breast pump and parts. 2. Connect the tubing to each air flow port. 3. To begin pumping, press and hold the power button on top of the pump motor. The device will power ON, indicated by the screen lighting up and will be in SYNC mode. 4. If you are single pumping, press the play/pause button to pause the motor for the breast you will not be pumping. 5. To adjust suction (vacuum) strength while in SYNC Mode, use the level buttons to select preferred suction strength/ level. (Levels 1-5 (Massage Mode) / Levels 6-12 (Expression Mode) 15 6. To adjust the suction (vacuum) strength for each breast independently, press SYNC button to power SYNC off (“SYNC” light in center of screen will turn off and Pump 1 will begin to flash). 7. Press the “SELECT” button to choose which pump to adjust (“Pump 1” or “Pump 2” will flash when chosen). Then use the level buttons to select preferred suction strength/level. Press “SELECT” again to adjust the suction strength/level on the other side. 8. At any time, press the play/pause button for pump 1 or 2 to pause and start pump operation. 9. To return to using the same suction level for both sides, press the "SYNC" button. The SYNC light will appear in center of screen, and the suction level will default to the lowest suction level set between the two pumps. 10. When you wish to stop expressing, press the Power button and then remove the milk collection kit from your breast. 16 11. Close the bottle(s) tightly with bottle disk and cover, and store safely. 6.6 Suction Settings 1. The Cimilre S5 Plus will automatically remember your last settings for your next pumping session. If you want to start pumping on different settings, adjust the settings before you start expressing. 2. The suction (vacuum) level refers to the suction strength; this is measured in millimeters of mercury (mmHg). When you are using the Cimilre S5 Plus, you will usually find that expressing is most effective on the highest suction level that is comfortable for you. However, it’s important not to set suction level so high that it makes you uncomfortable or causes pain as this can hinder your milk flow. ! While some discomfort may be felt when first using a breast pump, using a breast pump should not cause pain. If you are feeling strong discomfort or pain while using the breast pump or unsure about breast flange sizing, immediatley stop use and contact a healthcare professional. 6.7 Massage and Expression Modes Massage Mode: Suction pattern with fast cycle speed and low suction to help encourage a letdown and to start milk flowing. Expression Mode: Suction pattern with slower cycle speed and higher suction to express milk gently and efficiently. 17 10. Disposal As an electrical and electronic equipment, the device must be disposed of according to a specialized procedure for collection, pick-up and recycling or destruction in accordance with Directive 2012/19/EU of the European Council on Waste Electrical and Electronic Equipment [WEEE]. Please properly dispose the Class II medical device in accordance with local, state and federal regulations. 11. Technical Information Contents Rated voltage and frequency Description Input: DC 5V, 2A Power consumption 0.4 A Battery / Life 3.7V 2300mAh Li-Polymer / 2 hours + Protection on electronic shock Class II, Degree of protection against ingress of water IP Classification: IP22 TYPE BF Applied Part Operation mode (Continuous operation) Expression, Massage, Sync Mode Suction levels Cycle speeds Single/Double Expression Mode 6 - 12 Levels Massage Mode 1 - 5 Levels Expression Mode Fixed (24-35) Massage Mode Fixed (52-93) Single/Double Timer function Automatic Off ( 30 min ± 1 min) Noise Less than 45 dB Backflow protection Yes Cleaning Method for Accessories Boiling water Operating conditions Ambient temperature 41 to 104°F Relative humidity 20 to 80 % Air pressure 700 to 1,060 hPa 80 40 106 5 20 Temperature 70 Humidity Pressure Transport and storage conditions 22 Ambient temperature -4 to 122°F Relative humidity 20 to 95 % Air pressure 500 to 1,060 hPa 95 50 106 -20 20 Temperature Humidity 50 Pressure REV 0.2 2022.03.04 QF-708-22 UM-115(0.2)
advertisement
Related manuals
advertisement