Reklam
Reklam
DDS 5900
User Manual
Digital Discussion System
DDS 5900 Digital Discussion System
Danish Interpretation Systems DIS
Danish Interpretation Systems User Manual
Copyright © 2012 DIS User Manual DDS 5900 02/05/2012
No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.
1 List of Contents
1 List of Contents ........................................................3
2 Important ..................................................................5
Imp ortant Safeguards .................................5
Labels.................................................................. 6
Note for Power Connections..................... 6
Power Disconnect ......................................... 7
Compliancy .....................................................7
Cleaning ...........................................................7
Repacking........................................................7
Warranty .........................................................8
3 Your DDS 5900 Conference System...................9
Sys tem overview ...........................................9
CU 5905 Central Unit................................... 9
DC 5980P Portable Conf. Unit.................. 9
GM 59xx Gooseneck Microphone........... 9
Sys tem technology........................................9
Sound transmission....................................10
Features...........................................................10
Cabling..............................................................10
Sys tem components .................................. 10
DDS 5900 Conference System ...............10
Supported units, DCS 6000 System.....10
Getting Started ...................................................... 11
Setting up the system the first time ..... 11
Connecting a PC .......................................... 12
Cabling guidelines ..................................... 12
Max . number of units to be connected 13
CU 5905 – DC 5980P, one chain............13
CU 905 – DC 5980P, two chains .........13
CU 5905 – DC 5980P – JB 6104, one chain 13
CU 5905 – DC 5980P – JB 6104, two chains 13
5 CU 5905 Central Unit...........................................15
Overview.......................................................15
Audio Schematic .........................................16
Installation ...................................................16
Con nections..................................................17
Connecting DC 5980P Units....................17
Connecting a PC ...........................................18
Connecting a PC and an iPad..................19
Connecting an audio recorder...............19
Connecting an audio mixer.....................20
Connecting interpretation units...........21
Using wireless language distribution.22
Connecting an emergency signal..........23
Usi ng the Interactive Menu.....................23
Overview.........................................................23
Navigate through the menu....................23
b Browser Setup and Control ...........24
CU 5905 Setup (browser)........................24
CU 5905 Mic Control (browser) ...........31
Using Web browser in PC........................32
Using Web browser in iPad ....................33
Ope ration Modes ........................................34
Operation Mode ...........................................34
Delegate Interrupt Mode .........................34
DC 5980P Conference Unit ................................35
Overview.......................................................35
Pre paring the conference unit...............35
Conference Unit Overlays........................35
Other languages, CM & IS.........................36
Attaching Overlays .....................................36
User Manual DDS 5900 3
Configuration of the unit..........................36
Delegate Unit............................................... 36
Chairman Unit............................................. 37
Interpreter Unit.......................................... 37
7 GM 59xx Gooseneck Microphones.................. 38
8 Troubleshooting................................................... 39
9 Technical Specifications .................................... 41
System Specification ................................. 41
CU 5905 Specifications............................. 41
DC 5980P Conference Unit...................... 42
GM 59xx Gooseneck Microphones........ 42
Connection Details .................................... 43
Accessories .................................................. 44
10 External Control Application Protocol 45
General Protocol behaviour ................... 45
TCP/IP soc et connection .......................45
Command structure (from External
Contro l to CU 5905) .......................................................
Command structure (from CU 5905 to
Seat numbering ............................................47
CU 5905 reply to commands..................47
Retrieving system status..........................47
Microphone Control.................................. 47
Commands from External Control to CU
Commands from CU 5905 to External
Audio Control .............................................. 52
Commands from External Control to CU
Commands from CU 5905 to External
4 User Manual DDS 5900
Danish Interpretation Systems User Manual
2 Important
2.1 Important Safeguards
1 Read these instructions ‐ All the safety and operating instructions should be read before the apparatus or system is operated.
2 Keep these instructions ‐ The important safety instructions and operating instructions should be retained for future reference.
3 Heed all warnings ‐ All warnings on the apparatus and in the operating instructions should be adhered to.
4 Follow all instructions ‐ All instructions for installation or use/operating should be followed.
5 Do not use this apparatus near water ‐ Do not use this apparatus in a water or moistures environment ‐ for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, near a swimming pool, in an unprotected outdoor installation, or any area which is classified as a wet location.
6 Warning: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and no objects filled with liquids, such as vases, should be placed on this apparatus.
7 Clean only with dry cloth ‐ Unplug the apparatus from the outlet before cleaning. Do not use liquid cleaners or aerosol cleaners.
8 Do not block any ventilation openings.
Install in accordance with the
manufacturer’s instructions ‐ Openings in the enclosure, if any, are provided for ventilation and to ensure reliable operation of the apparatus and to protect it from overheating.
These openings must not be blocked or covered. This apparatus should not be placed in a built‐in installation unless proper ventilation is provided or the manufacturer’s instructions have been adhered to.
9 Do not install near any heat sources such as radiators, heat registers, stoves, air ducts, or other apparatus (including amplifiers) that produce heat.
10 Do not install the unit in a place exposed to direct sunlight, excessive dust or humidity,
mechanical vibration or shock.
11 To avoid moisture condensations do not install the unit where the temperature may rise rapidly.
12 Do not defeat the safety purpose of the
polarized or groundtype plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
13 Protect the power cord from being walked on or pinched particularly at plug, convenience receptacles, and the point where they exit from the apparatus.
14 Only use attachments/accessories specified
by the manufacturer. Any mounting of the apparatus should follow the manufacturer’s instructions, and should use a mounting accessory recommended by the manufacturer.
15 Use only with the cart, stand, tripod, bracket or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip‐over ‐
Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn.
User Manual DDS 5900 5
16 Unplug this apparatus during lighting storms or when unused for long periods of
time. – Not applicable when special functions are to be maintained, such as evacuation systems.
17 Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
18 Replacement Parts ‐ When replacement parts are required, be sure the service technician has used replace ment parts specified by the manufacturer or having the same characteristics as the original part.
Unauthorized substitutions may result in fire, electric shock or other hazards.
19 Safety Check ‐ Upon completion of any service or repairs to this apparatus, ask the service technician to perform safety checks to determine that the apparatus is in proper operating condition.
20 Overloading ‐ Do not overload outlets and extension cords as this can result in a risk of fire or electric shock.
21 Power Sources ‐ This apparatus should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply you plan to use, consult your appliance dealer or local power company. For apparatuses intended to operate from battery power, or other sources, refer to the operating instructions.
22 Power Lines ‐ An outdoor system should not be located in the vicinity of overhead power lines or other electric light or power circuits, or where it can fall into such power lines or circuits. When installing an outdoor system, extreme care should be taken to keep from touching such power lines or circuits, as contact with them might be fatal.
23 Object and Liquid Entry ‐ Never push objects of any kind into this apparatus through openings as they may touch dangerous voltage points or short‐out parts that could result in a fire or electric shock.
Never spill liquid of any kind on the apparatus.
Should any liquid or solid object fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it further.
2.1.1 Label s
“Lightning Flash Symbol” with the lightning flash with arrowhead symbol within an equilateral triangle, is intended to constitute a risk of s alert the user to the presence of un‐insulated "dangerous voltage" within the product enclosure that m ay be of sufficient magnitude to hock to persons.
“Exclamation Point Symbol” with the exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance accompanying the product.
(servicing) instructions in the literature
2.1.2 Note for Power Connections
Check that the voltage of your local power supply is within the operating voltage of the unit. If a voltage conversion is required, consult your DIS dealer or qualified personnel.
Set the Power switch to ‘Off’ if it is not used for several days. earth (ground) n
T he wir es in the main equipment are colored i following codes: lead supplied with the n accordance with the
Green‐and‐yellow E arth (Groun d)
6 User Manu al DDS 5900
Blue
Brown
Neutral
Live g y c ed to the terminal in the plug marked with the letter E or with the safety earth symbol or marked with green‐and‐ yellow color.
The blue wire must be connected to the terminal marked with the letter N or marked with black color.
The brown wire must be connected to the terminal marked with the letter L or marked with red color.
2.2 Compliancy
The equipment has been tested and found to comply with the limits of the following standards for digital devices:
• EN55103‐1 (Em
• EN55103‐2 (Im
• EN60065 safety ission) m unity)
• UL6500 safety
The device complies with part 15 of the FCC rules.
Operation is subject to the following conditions: (1)
The device may not cause harmful interference, and
(2) the device must accept any interference received, including interference that may cause undesired operation .
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in residential, commercial or light industrial environments. The equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the user manual it may cause harmful interference to radio communications.
2.3
To keep the cabinet in its original condition, periodically clean it with a soft cloth. Stubborn stains may be removed with a cloth lightly dampened with a
2.4 Repacking
Save the original shipping cardboard box and packing material; they will become handy if you ever have to
For pluggable equipment, the socket‐outlet shall be installed near the equipment and shall be easily accessible.
2.1.3 Power Disconnect
Apparatuses with or without On/Off switches have power supplied to the apparatus whenever the power cord is inserted into the power source; however, the apparatus is operational only when the On/Off switch is in the On position. The power cord is the main power disconnect for all apparatuses.
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this e quipment.
Operation of this equipment in residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Intentional or unintentional changes or modifications not expressly approved by the party responsible for compliance shall not be made. Any such changes or modifications could void the user’s authority to operate the equipment.
If necessary, the user should consult the dealer or an experienced radio/ television technician for corrective action.
Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. mild detergent solution. Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet. ship the unit. For maximum protection, re‐pack the unit as originally packed from the factory.
User Manual DDS 5900 7
2.5
Warranty
The units are minimum covered by 24 months warranty against defects in materials or work‐ m anship.
8 User Manual DDS 5900
3 Your DDS 5900 Conference System
3.1 System overview
DDS 5900 Digital Discussion System is a system to be used at meetings, where a number of people are addressing the ‘Floor’ in a structured manor. The sound form the conference units can then be heard in
The system does also allow for simultaneous interpretation for international conferences where multiple languages are used.
To enable all participants to understand the proceedings, interpreters can simultaneously translate the speaker’s language as required. These interpretations are distributed through the connected conference units and delegates can select the language of their choice and listen to it through headphones.
DDS 5900 Digital Discussion System comprises of one
Central Unit and a number of Conference Units and
Gooseneck Microphones.
3.1.1 CU 5905 Central Unit
3.1.2 DC 5980P Portable Conf. Unit
Figure 3.1-B e U
The conference unit can be configured for the follo wing functionality:
• Delegate with Speak/Request button
• Delegate with Speak/Request and Mute button
• Chairman with S
• Interpreter Unit peak and Delegate Off button
3.1.3 GM 59xx Gooseneck
Microphone
Figure 3.1-A CU 5905 Central Unit
The central unit is the core of the DDS 5900 Digital
Discussion System. Only one CU 5905 can be used in each system.
3.2 System technology
Figure 3.1-C GM 9xx Gooseneck Microphones.
The Gooseneck Microphones are available in two lengths, 40 cm and 50 cm and are detachable from the conference unit, but can be fixed using a tool.
User Manual DDS 5900 9
3.2.1 Sound transmission
The DDS 5900 Digital Discussion System is based on a digital transmission of sound from the conference unit to the central unit and back again to the built in loudspeake rs in t he units.
The sound transmission is fully encrypted to avoid eavesdropping.
3.2.2 Features
The DDS 5900 Digital Discussion System has the follo wing main fe atures:
• Fully digital
• Excellent sound quality
• “State of the Art” fully digital integrated discussion system offering interpretation and language distribution.
• Unique digital DATA and AUDIO bus named DCS‐
LAN.
• 10 incoming channels (8 floor channels + 2 interpreter ch annels) and one Audio input.
• 3 distributed channels (1 floor + 2 interpreted channels)
3.3 System components
3.3.1 DDS 5900 Conference System
The DDS 5900 syst em consi st of the following units:
CU 5905
DC 5980P
GM 5923
GM 5924
SB 5980
Central Unit
Portable Conference Unit
Gooseneck Microphone, 40 cm
Gooseneck Microphone, 50 cm
Storage Box 10 DC 5980P and GM 59xx
3.3.2 Supported units, DCS 6000
System
The following units from the DCS 6000 Digital
Conference System can be used in the DDS 5900 system:
• The conference units are powered and controlled by the CU 5905 Central Unit, which drives up to
60 units on 2 chains.
• If more units are required the EX 6010 Extension
Unit or PS 6000 Power Supply is available
• A total of 250 conference units can be connected to the system.
• TCP/IP connection on CU 5905 for external operation of the system using a PC or a control system such as AMX ® or Crestron ®.
3.2.3 C abli g
The DDS 5900 system is using screened CAT5e cabling (F/UTP or U/FTP) ensuring a very cost effective installation and easy set‐up of portable systems
The conference units are daisy chain connected to the central unit.
The number of units, which can be connected to a central unit, depends on length of the feeding cable a nd the length of the cable between each unit.
EX 6010
PS 6000
RP 6004
JB 6104
DH 6021
GM 6523
G M 6524
Extension Unit
Power Supply
Repeater/Splitter for four ch
Junction Box with 4 outputs ains
Delegate Headphone
Gooseneck Microphon e, 40 cm
Gooseneck Microphon e, 50 cm
GM 6622 Shotgun Microphone
For detailed instruction in how to use the above units, please refer to the User Manuals for the relevant products.
10 User Manual DDS 5900
4 Getting Started
4.1 Setting up the system the first time
When setting up the system for the first time please follow the instruction given in this section in sequence.
1. Unpack the CU 5905 Central Unit and the DC
5980P Conference units and place them
2. Attach the button overlays to the DC 5980P units. Use the overlays delivered with the units for Delegate units and use the overlays delivered with the CU 5905 for Chairman and
Interpreter units.
Please refer to section ‘6.2 Preparing the
conference unit’ for details.
Please note, that the overlays are NOT designed to be removed after attachment.
3. Connect the power cord to the CU 5900 Power
Supply and connect the cable from the power supply to the CU 5905.
Please refer to section ‘5 CU 5905 Central Unit’
for details
4. Connect the units with Chairman and
Interpreter overlays to the DCS‐LAN connector(s) on the CU 5905 using EC 6001‐xx
Cat5e extension cables.
5. Turn power ‘On’ to the CU 5900 Power Supply.
The light indication in the power switch on the
CU 5905 will light red.
6. Activate the power switch on the CU 5905 and the light indication in the button will light green. After about 15 seconds, the display in the CU will be visible and the Led’s in the button overlay on the DC 5980P will flash until the units are registered (less than 60 seconds).
7. Check that the units are working by touching the ‘Speak’ button.
Please refer to section ‘6 DC 5980P Conference
Unit’ for details.
8. Change the unit type according to the attached overlay.
Please refer to section ‘6.2.4 Configuration of the unit’ for details
9. Turn Off power
10. Place all units at the positions, where they are
11. Connect the units with EC 6001‐xx Cat5e extension cables in suitable length to the DCS‐
LAN connector(s) on the CU 5905 observing that the cables are not bended to a radius less than 15 mm.
Please refer to section ‘4.3 Cabling guidelines’ for details.
12. Connect the GM 59xx Gooseneck Microphone to the unit
13. If needed fix the gooseneck microphones to the units with the tool delivered with the CU 5905.
Please refer to section ‘7 GM 59xx Gooseneck
Microphone’ for details.
14. Turn ‘On’ power and wait for the system to become ready.
15. Touch the ‘Speak’ button on the units to check functionality.
16. Adjust the ‘Loudspeaker volume’ to a desired level using the interactive menu on the front of the CU 5905.
Please refer to the section ‘5.5 Using the
Interactive Menu ’ for details.
User Manual DDS 5900 11
4.2 Connecting a PC
When connecting a PC direct to the CU 5905 please follow the instruction given in this section in sequence.
1. Connect the PC and the CU 5905 with a standard LAN cable
2.
Turn ‘On’ power to both units
3. On the PC check that the network setting is set to btain an IP address automatically’: a. Navigate to ‘Control Panel * Network and
Sharing Center * Change adapter settings *
Local Area Connec tion’. b. Select ‘Properties’ c. Select ‘Internet Protocol Version 4
(TCP/IPv4) d. Click ‘Properties’ e. Change setting to ‘Obtain an IP address automatically’
4.3 Cabling guidelines
The DC 5980P Conference Units are connected to the
CU 5905 Central Unit using Cat5e F/UTP or U/FTP screened cables, however the following guidelines has to be observed:
• Maximum cable length in one chain is 150 m
(before inserting RP 6004 Repeater in a chain). This includes interconnection cables between the units. The maximum usable cable length depends on the units connected and length of feeding cables etc.
• Cables must be AWG24 if the number of units in the tables are to be used. AWG26 cables will not allow as many units. DIS cables series EC 6001‐xx are all AWG 26.
• Maximum cable length in one chain when using RP 6004 Repeaters and Cat5e cables is
450 m.
4. Using the interactive menu on the CU 5905 navigate to:
6.
b. Select ‘Dynamic’.
5. Using the interactive menu on the CU 5905 navigate to: a. LAN setup * IP address setup * IP address *
Actual IP address b. Note the IP address
7. Type in the internet browser: ‘http://IP‐ address’, where ‘IP address’ is the address noted from the CU 5905
8.
The CU 5905 browser interface will open.
Please refer to section ‘5.6 Web Browser Setup and
Control’ for details about using the CU 5905 web browser.
Although the ‘Chain’ output connectors have a 150 W supply, this 150 W power is not all available with long cables, as there will be a power drop in the feeding cable from the CU 5905 Central Unit to the units connected.
If the feeding cables are short and the cables between the units are short, more units can be connected than if the feeding cable is long and/or the cables are long between the units.
Please consult the next sections for details about the number of units, which can be connected depending o n the cable length.
12 User Manual DDS 5900
4.4 Max. number of units to be connected
The following tables shows the maximum number of units, which can be connected to a CU 5905 Central
Unit or to an EX 6010 Extension Unit or a PS 6000
Power Supply
In the tables the ‘Feeding Cable’ is defined as the cable between the CU 5905 (or EX 6010 / PS 6000) and the first DC 5980P and the ‘Interconnecting Cable is defined as the cable connecting two DC 5980P.
Length of
Feeding Cable
10 m
30 m
50 m
100 m
10 m
30 m
50 m
100 m
Length of inter connecting cable,
1 m
1 m
1 m
1 m
2 m
2 m
2 m
2 m
Total cable length
2x39 m
2x58 m
2x76 m
2x122 m
2x66 m
2x84 m
2x100 m
2x142 m
Max. number of DC 5980P
Using both output
2x30
2x29
2x27
2x23
2x29
2x28
2x26
2x22
Figure 4.4-B Number of units connected using both chains
4.4.1 CU 5905 – DC 5980P, one chain
The following table shows the maximum number of units, which can be connected to a CU 5905 Central
Unit when using only one of the two ‘Chain’ outputs.
The table also shows the number of units, which can be connected to each ‘Chain’ output on an EX 6010
Extension Unit or to the ‘Chain’ output of a PS 6000
Power Supply.
Length of
Feeding Cable
10 m
30 m
50 m
100 m
10 m
30 m
50 m
100 m
Length of inter connecting
Cable
2 m
2 m
2 m
2 m
1 m
1 m
1 m
1 m
Total cable length
63 m
77 m
91 m
128 m
104 m
114 m
122 m
140 m
Max. number of DC 5980P using one output only
48
43
37
27
54
48
42
29
Figure 4.4-A Number of units connected using only one chain outpu on CU 5905
4.4.3 CU 5905 – DC 5980P – JB 6104, one chain
This configuration shows two DC 5980P Conference
Units each connected to an output on a JB 6104
Junction Box with 3m cables between each JB 6104.
General note: Maximum cable length from a JB 6104 to a DC 5980P is 5 m and maximum one DC 5980P is allowed on each output of a JB 6104.
Length of
Feeding
Cable
10 m
30 m
50 m
100 m
Length of cable between each JB 6104
Total cable length
Number of JB
6104
3 m
3 m
3 m
3 m
76 m
87 m
92 m
133 m
23
20
15
12
Max. number of DC
5980 P
46
40
30
24
Junction Box, using on chain on CU 5905
4.4.2 CU 5905 – DC 5980P, two chains
The following table shows the maximum number of units, which can be connected to both ‘Chain’ outputs simultaneously on a CU 5905 Central Unit in total using only the supplied CU 5900 Power Supply.
If only one ‘Chain’ is used the information in the table above must be used.
4.4.4 CU 5905 – DC 5980P – JB 6104, two chains
This configuration shows two DC 5980P Conference
Units each connected to an output on a JB 6104
Junction Box with 3m cables between each JB 6104.
User Manual DDS 5900 13
Danish Interpretation Systems
Length of
Feeding
Cable
10 m
30 m
50 m
100 m
Length of cable between each JB
6104
3 m
3 m
3 m
3 m
Total cable length
2x46 m
2x63 m
2x83 m
2x127 m
Number of JB
6104
Max. number of DC
5980 P
2x13
2x12
2x12
2x10
2x26
2x24
2x24
2x20
Junction Box, using two chains on CU 5905
User Manual
14 User Manual DDS 5900
Danish Interpretation Systems User Manual
5 CU 5905 Central Unit
5.1 Overview
The CU 5905 Central Unit for the DDS 5900 is the heart of the system. One CU 5905 is needed in each
DDS 5900 system.
The CU 5905 Central Unit has the following functionality and features:
• Up to 250 Conference Units
• Secure audio transmission
•
•
Vox (voice activating)
2 Interpretation Channels
• Designed in a standard 1HE 19” cabinet
• CU 5900 External Power Supply for CU 5905 for up to 60 Conference Units
The CU 5905 is suitable for either table‐top or 19‐ inch rack‐mounted use. Four feet (for table top use) and two mounting brackets (for rack mounting) are supplied.
Figure 5.1-B Back view of CU 5905
1. Power Supply input – Connection of the external
CU 5900 Power Supply (48V/3A). The power supply is provided together with the CU 5905.
Fig ure 5.1-A Front v iew of CU 5905
1. Menu display – A 2x20 character OLED‐display is used as an interactive display for configuring the system.
2. Menu buttons – 5‐button keypad for configuring the unit in combination with the display (1).
3. Mains on/off switch – After switching the mains on, the central unit starts up and the display (1) will light‐up after app. 15 seconds. Any connected
EX 6010 Extension Units or PS 6000 Power
Supply will automatically be powered up. The indication in the switch is lighting Green, when power is switched ‘On’. A red light indicates that power is connected to the central unit, but the unit is not switched ‘On’ (Standby).
Figure 5.1-C CU 5900 Power Supply
2. Chain outputs – Two RJ45 connectors for connecting DC 5980P conference unit. The connection and protocol is called DCS‐LAN.
Important: The ‘Chain’ outputs are only for connecting DC 5980P Conference unit.
Connecting a LAN (TCP/IP) connection from a third part device to this output may damage both the third part device and the CU 5905.
3. LAN (TCP/IP) connector – A RJ45 connector for connection to local area network (LAN). This connector is used to connection to the built in web application or for connection to a control system like AMX® or Crestron®.
4. Audio output A, B, C & D – 4 male XLR3 connectors to connect to PA systems, Audio
Mixers, Audio Recorders or Language
Distribution System etc.
5. Audio input In 1 & In 2 – Two female XLR3 connectors for extra audio inputs. ‘In 1’ is used to connect auxiliary symmetrical audio signals such
User Manual DDS 5900 15
Danish Interpretation Systems User Manual as a wireless microphone to the floor language.
‘In 2’ is used for connection of an “Emergency
Evacuation Message (EEM)” audio signal.
6. Emergency switch connector – A terminal block socket for a single, ‘normally open’ switch. When the switch is closed, the audio signal on the ‘In 2’
5.2 Audio Schematic connector is distributed on all output channels, overriding all other audio inputs.
Note: There is no volume control available for setting the volume on ‘In 2’. The volume has to be set at the equipment generating the “Emergency Evacuation
Message (EEM)” audio signal.
Figure 5.2‐A DDS 5900 Digital Discussion System Audio Schematic
5.3 Installation
The CU 5905 Central Units can be placed on a table or d
When installing in a 19” rack the supplied 19” brackets shall be fixed to the front side of the CU 5905
Central Unit by unscrewing the crews holding the top and button cover and then fix the brackets using the same screws.
The unit has a built‐in fan taking air in at the left side of the unit and blowing the hot air out at the right side. That allows units in 19” racks to be stacked close with other units without extra room for cooling air between them.
P lease check that the other units will allow this.
16 User Manual DDS 5900
Danish Interpretation Systems User Manual
5.4 Connections
This chapter gives an overview of typical system connections using the CU 5905 Central Unit:
t
A lthough the schematics are typical and are intended o give a general overview, combinations of the
5.4.1 Connecting DC 5980P Units
The DC 5980P Conference Units are connected to the
CU 5905 using EC 6001‐xx Cat5e cables. This is the basic connection of the system.
Both of the DCS‐LAN connectors on the CU 5905 can be used for connecting DC 5980P Conference units.
schematics are however not only possible, but very c ommon used.
Refer to section ‘4.4.2 CU 5905 – DC 5980P, two c hains ’ when using two chains.
Figure 5.4-A Connecting the DDS 5900 Digital Discussion System.
User Manual DDS 5900 17
Danish Interpretation Systems User Manual
5.4.2 Connec ing a PC
The CU 5905 is connected to the DC 5980P
Conference Units using EC 6001‐xx Cat5e cables and
B
rowser ’ for more information.
Hint: On older PC’s it might be needed to setup a fixed IP address on both the PC and the CU.
Note: Depending on the type of PC a ‘Crossed’ LAN cable has to be used.
Instead of using a ‘Crossed’ LAN cable, a LAN Router can be inserted.
Figure 5.4-B Connecting the DDS 5900 Digital Discussion System to a PC
18 User Manual DDS 5900
Danish Interpretation Systems User Manual
5.4.3 Connecting a PC and an iPad
The CU 5905 is connected to the DC 5980P
Conference Units using EC 6001‐xx Cat5e cables.
A wireless access point with built‐in router is used for connection to the CU 5905 and the PC. The iPad is connected wireless.
Opening the browser in the PC or on the iPad gives the option of configuring the system and controlling
Please refer to section ‘5.6 Web Browser’ for more
information.
Figure 5.4-C Connecting the DDS 5900 Digital Discussion System to a PC and an iPad
5.4.4 Connecting an audio recorder
The CU 5905 is connected to the DC 5980P
Conference Units using EC 6001‐xx Ca t5e cables.
This configuration is used when ‘Floor’ sound or sound from one or more microphones is required to be recorded.
W
User Manual DDS 5900 19
Danish Interpretation Systems User Manual
Figure 5.4-D Connecting the DDS 5900 Digital Discussion System to an audio recorder.
5.4.5 u o i
The CU 5905 is connected to the DC 5980P
Conference Units using EC 6001‐xx Cat5e cables.
This configuration is used when the volume from one or more microphones is required to be controlled separately or equalisation is needed. One or more
Outputs are connected to the external mixer, where the control or equalisation is done.
t
The sound from the audio mixer is then send back to he CU using the ‘Audio In 1’ input.
Important: If ‘Out A’ is send to the mixer the
following settings must to be done:
‘CU 5905 Setup * Audio * Loudspeaker Control * Microphone ‐>
Loudspeaker’ shall be set to ‘Off’.
‘Out.A’ shall be un‐selected in the selection ‘CU 5905 Setup * Audio
* Input/Output Control * Audio In 1’.
Figure 5.4-E Connecting the DDS 5900 Digital Discussion System to an audio mixer.
20 User Manual DDS 5900
Danish Interpretation Systems User Manual
5.4.6 Connecting interpretation units
The CU 5905 is connected to the DC 5980P
Conference Units using EC 6001‐xx Cat5e cables.
Both the DCS‐LAN connectors on the CU 5905 can be u sed for connecting DC 5980P Conference units.
In this example two units are configured as
Interpreter Units and DH 6021 Headphone is connected to the units. Sound from the Interpreter
Units can then be heard in the headphones connected to the Chairman and Delegate Units.
Figure 5.4-F Connecting the DDS 5900 Digital Discussion System with interpretation functionality.
User Manual DDS 5900 21
Danish Interpretation Systems User Manual
5.4.7 u e s
The CU 5905 is connected to the DC 5980P
Conference Units using EC 6001‐xx Cat5e cables.
Both the DCS‐LAN connectors on the CU 5905 can be used for connecting DC 5980P Conference units.
In this example two units are configured as
Interpreter Units and DH 6021 Headphone is connected to the units. Sound from the Interpreter
ion
Units can then be heard in the headphones connected
e
A wireless language distribution system like ‘DCS
6000 Digital Infrared Language System’ can then be
‘Floor’ and interpreter channels. Refer to section ‘5.6
Figure 5.4-G Connecting the DDS 5900 Digital Discussion System with interpretation functionality
22 User Manual DDS 5900
Danish Interpretation Systems User Manual
5.4.8 Connecting an emergency signal
To use the emergency signal function, a switch
(normally‐open) must be connected to the emergency switch connector. When the switch is closed an
“Emergency Evacuation Message (EEM)” audio signal
5.5 Using the Interactive Menu
5.5.1 Overview
The major configurations and operation options of the CU 5905 can be set via an interactive menu, using the 2x20 character OLED display and the 5‐button keypad.
Browser’, where all CU 5905 settings are explained.
present on the ‘In 2’ input is distributed to all output channels, overriding all other audio inputs.
Important: The level of the signal must be controlled externally.
Figure 5.5-A Menu overview
5.5.2 Navigate through the menu
Navigation in the menu and changing parameters is done by activation the 5‐button keypad:
Cycle through the menu items (Blue marking) with the four ‘arrow’ buttons (Left‐Right, Up‐
Down).
Navigate to a settable option (Green marking).
Cycle through the available values for a settable option using the ‘arrow’ buttons Up‐Down.
Press the ‘Enter’ button in the centre to accept the value. Pressing the Enter button concludes the selection made, and at the same time it indicates a confirmation of the possible changes made within the i selection. Please note that some changes are applied mmediately, and confirmation is thus not required.
User Manual DDS 5900 23
Danish Interpretation Systems User Manual
5.6 Web Browser Setup and Control
5.6.1 CU 5905 Setup (browser)
All configurations and operation options of the CU
5905 can be set using a web browser in a PC, tablet or iPad. When the ‘IP address’ or ‘Host Name’ is typed into the browser the connection to the CU will be established and the ‘CU 5905 Setup’ screen will be opened in the browser.
Important: The ‘CU 5905 Web Browser Control’ has been tested with the following browsers:
IE8/9+, Firefox 10+, Safari and Chrome
Other browsers might work but have not been tested.
Version of IE prior to v8 will not work.
Figure 5.6-A CU 5905 Setup
The next tables show all menu items in the browser menu and a detailed description of the settings available.
# Menu Settings Description
1. There are six menu options in the browser control. The first five options select sub‐menus for configuring and setting up the CU
5905.
The last menu option switches to the Microphone Control screen.
24 User Manual DDS 5900
Danish Interpretation Systems User Manual
# Menu
2.
3.
Settings
Description
Shows the connected conference units with Serial Number and Type of units. The ‘State’ field shows if a unit is ‘Active’ (connected) or ‘Lost’
(not connected).
If a unit is shown as ‘Locked’ the unit is not compatible with the DDS
5900 System
Shows the number of connected units on each chain.
CU hostname –
A host name can be assigned to the
CU 5905. This name can be used to connect to the CU 5905 with a browser instead of using the IP‐ address.
After a hostname is assigned, type the following in the browser: http://’hostname’.local where ‘hostname’ is to be replaced with the assigned name.
IP con guration –
Select ‘Dynamic’ if the CU is connected to a network with DHCP server. Otherwise select ‘Static’ and assign a fixed IP address to the CU.
Default IP addr ess is 192.168.10
.1.
Select ‘Apply Changes’ to save changes made.
The actual IP address can always be found in this screen or using the interactive menu on the CU 5905:
LAN setup * IP address setup * IP address * Actual IP address.
User Manual DDS 5900 25
Danish Interpretation Systems
# Menu
4.
5.
6.
26
User Manual
Settings
Description
Password Setup –
Used for setting ‘User name/Password’ for browser connection.
Loudspeaker Control –
The ‘Loudspeaker Volume’ is setting the volume of the built‐in loudspeakers in the Conference units.
The ‘On/Off’ button is used for switching on/off the audio from the conference units to the built‐in loudspeakers and headphones. Only audio from ‘Seats’ (units) selected in
‘Group A’ will be available in the loudspeakers.
Input/Output Control –
The ‘Audio In 1 Volume’ is used to set the level of the input signal.
The gain of the ‘Audio In’ signal can be set to ‘0 dB’ or ‘10 dB’. When set to ‘10 dB’ the input signal is amplified 10 dB.
The ‘Audio In 1’ signal can be routed to the ‘Loudspeakers’ (including headphones) in the conference units as well as to ‘Out. A’ output using the two selection buttons.
The ‘Audio In 1’ signal will only be present at ‘Out. A’ if ‘Group’ is selected as the source to the ‘Out A’ output, where it will be mixed with the ‘Group A’ signal. See next menu point.
The ‘Audio Out Volume’ can be set for the four audio outputs (A, B, C and D).
User Manual DDS 5900
Danish Interpretation Systems
# Menu
7.
Settings
User Manual
Description
The ‘Source’ can be selected for each of the four outputs. The choices using the dropdown menu are:
Group, Floor, Ch.1 or Ch.2
When ‘Group’ is selected for ‘Out A’, the ‘Group A’ is the source and similar for the three other outputs.
The ‘Floor, Ch.1, Ch.2’ selection is used either for recording of the interpreted languages or for connection to a wireless language distribution system.
If ‘Floor, Ch.1, Ch.2’ is selected for an output (Out A, B, C or D) the corresponding group is disabled in the ‘Group Setup’
The conference units can be assigned individually to four groups.
‘Group A’ is always used as the source to the built‐in loudspeakers.
A unit can be selected in ‘Group A’ and/or in one of the other three groups. If a unit is not selected in
‘Group A’ the audio from this unit will not be available in the built‐in sp
The ‘Group’ facility is used if separate microphones are required to be recorded or if external equalisation or volume control is required.
Note: A microphone can only be present in ‘Group A’ and in one other group.
User Manual DDS 5900 27
Danish Interpretation Systems User Manual
# Menu
8.
9.
28
Settings
User Manual DDS 5900
Description
All units connected are shown in this list with ‘Serial Number’ and
‘Seat Number’.
When a unit is connected for the first time, it will be assigned the next ‘Seat Number’ and assigned a
‘Delegate Name’ in the format ‘Seat x’, where ‘x’ is the assigned seat number. The assigned ‘Delegate
Name’ can be changed to show the actual name of the delegate placed in the seat.
After assigning names, the ‘Submit
Changes’ has to be activated.
The ‘Seat Number’ can be changed as well. If the same number is typed into two seats, it is marked with a red frame and the ‘Submit Changes’ button is disabled. The ‘Seat
Number’ is a numerical in the range
1 to 65535 .
When the mouse curser is moved to a seat number field, the red light ring in the microphone in the corresponding conference unit is flashing until the curser is moved to another field or ‘Submit Changes’ has been activated. This feature makes it easy to re‐number the units.
If units are disconnected they are marked with a yellow indication in the list. The units can be removed from the list either individually or all by clicking the yellow button.
The ‘Reset Names’ button delete all assigned delegate names.
Unit Type Change –
When set to ‘On’, it is possible to
change the unit type of the connected conference units as
specified in section
Configuration of the unit’.
When set to ‘Off’ the unit type is locked and cannot be changed on the unit.
Danish Interpretation Systems User Manual
# Menu
10.
11.
12.
Settings
Description
Reset to Factory Defaults –
When the reset button is activated, the settings in the CU 5905 are reset to factory default.
When doing this from a browser, the IP and security settings aren’t changed.
To reset IP settings and security settings, use ‘Factory defaults’ on the interactive menu on the CU
5905.
Delegate Setup –
The number of ‘Max speakers: Total’ defines the maximum number of conference units, which can speak at the same time. This includes both
The number of ‘Max speakers:
Delegates’ defines the maximum number of Delegate conference units, which are allowed to speak at the same time.
Please observe that a Chairman Unit can always be switched ON as long as the number set in ‘Max. Speakers:
Total’ are not exceeded.
‘Maximum requests’ defines how many delegates requesting to speak which can be inserted into the
‘Request‘ list.
Used for switching between the operation modes. Please refer to the section ‘5.7 Operation Modes’.
When set to ‘On’ a delegate will interrupt another delegate, who is speaking, if the number of delegates speaking has reached the number specified in the setting ‘Max speakers:
Delegates’.
User Manual DDS 5900 29
Danish Interpretation Systems
# Menu
13.
Settings
14.
Figure 5.6-B CU 5905 Browser Setup
30 User Manual DDS 5900
User Manual
Description
Those settings determines the behaviour of the system when working in VOX mode
The ‘Voice detection threshold’ can be set to values ranging from ‘‐12 to ‘8’ in steps of ‘1’.
The default value is ‘0’. Setting to a lower value makes the microphone more sensitive.
The ‘Voice detection release time’ can be set to values from 1 to 10 seconds in 0.5 sec step.
This setting is used for setting the time from the delegate stops talking until the microphone turns off. The default value is 4 sec.
Auto Off –
When ‘Microphone Auto Off’ is set to ‘On’ a conference unit will automatic turn off the microphone when the delegate stops talking.
The time is determined by the ‘Auto
Off time’ setting.
The ‘Automatic Off Time’ sets the time from the delegate stops speaking until the microphone turns off. The value can be set from
5 to 60 seconds in 5 second steps.
The default value is 5 sec.
When the system is set to VOX mode Auto Off settings are disabled.
Report –
If a report is needed for factory diagnostic purposes.
The report can be printed using an installed printer on the PC or saved to a file.
Danish Interpretation Systems User Manual
5.6.2 CU 5905 Mic Control (browser)
The microphone control screen is selected by clicking the ‘Microphone Control’ button in the ‘CU 5905
Setup’ screen.
The next table shows the screens available with a description of the functionality available
#
15.
Screen
F igure 5.6-C CU 5905 Browser Setup
Description
The microphone control page gives the option of switching On/Off microphone and depending on ‘Operation mode’ setting microphones into the ‘Request to speak’ queue.
Brings the ‘Delegate Microphone (Speak)’ list. See #17 later in this table.
Request … –
Brings the ‘Delegate Microphone (Request)’ list. See #18 later in this table.
Next On –
Pressing the ‘Next On’ button turns on the first request on the request list
All Del. Off –
Pressing the ‘All Del Off’ button turns off all delegate microphones
All Req. Off –
Pressing the ‘All Req. Off’ button empties the ‘Requests’ list.
Operation mode –
User Manual DDS 5900 31
Danish Interpretation Systems
# Screen
16.
User Manual
17.
18.
Figure 5.6-D CU 5905 Microphone Control
5.6.3 Using Web browser in PC
Opening the ‘CU 5905 Setup’ in one window and the
‘CU 5905 Microphone Control’ in another window or tab makes it easy to switch between the two screens.
Description
Speakers –
Shows the list of active speakers. The number of list lines are defined by the setting in ‘Max. Total Speakers’.
An speakers is turned off by clicking the speaker name.
Requests –
Shows the list of delegates requesting to speak. The number of list lines are defined by the setting in ‘Maximum Requests’.
An delegate is turned on by clicking the speaker name.
Delegate Microphones (Speak) –
Shows the list of seats with delegates and chairmen. Clicking a name will turn on the m crophone.
If a unit is disconnected the seat will be greyed out and cannot be activated.
Delegate Microphones (Requests) –
Shows the list of seats with delegates and chairmen. Clicking a delegate name will place the delegate in the request queue. A
Chairman will not be placed in the request queue.
If a unit is disconnected the seat will be greyed out and cannot be activated.
32 User Manual DDS 5900
Danish Interpretation Systems User Manual
Figure 5.6-E CU 5905 Setup Tab selected
Figure 5.6-G Select ‘Add to Ho me Screen’
Click the ‘Add’ button and a shortcut to the ‘CU 5905
Setup’ is placed on the deskt op on the iPad.
Click ‘Microphone Control’ and in the similar way make a shortcut for this screen as well. The two shortcuts can now be activated separately opening the screens in
‘full screen mode’ .
Figure 5.6-F CU 5905 Microphone Control Tab selected
5.6.4 Using Web browser in iPad
Making shortcuts on the desktop for ‘CU 5905 Setup’ and the ‘CU 5905 Microphone Control’ makes it easy to start the required browser. The screen will start in
‘full screen mode’.
Open the CU 5905 Browser application using the
‘Safari’ browser on the iPad. Then select ‘Add to
Home screen’:
Figure 5.6-H CU 5905 Browser shortcuts on the desktop
User Manual DDS 5900 33
Danish Interpretation Systems User Manual
5.7 Operation Modes
5.7.1 Operation Mode
The “Operation Mode” determines the behavior of the microphone system.
• Auto (or Automatic) mode allows for the conference units to be switched on immediately upon touching the ‘Speak’ button.
This is indicated by a red light in the ‘Speak’ lamp and in the light ring in the gooseneck microphone. Touching the ‘Speak’ button again will turn the microphone off
A Chairman Unit can be considered as is always being in Auto or VOX mode.
• Manual mode features a request list, where
‘Delegates’ are inserted in a queue upon touching the ‘Speak’ button. This is confirmed by a steady green light in the ‘Request’ indication in the delegate unit. It is possible to cancel the request by touching the button again.
The delegate unit can only be switched ‘On’ using the CU 5905 browser interface on a PC/iPad or from a control system like AMX ® or Crestron ®.
This will be indicated by red light in the ‘Speak’ lamp in the conference unit. At this point the delegate can switch off the microphone by touching the ‘Speak’ button.
Note: Manual mode is never selected/used on CU
5905 if a Browser, AMX ®, Crestron ® or other
“Control Facility” is not connected.
• FIFO is an automated mode. The conference unit functions in the same way as in ‘automatic’ mode as long as the number of turned on delegate units is less or equal to the selected maximum speakers.
When the max. number is reached, the next delegates touching their ‘Speak’ button will be placed in the request queue until the maximum requests is reached. The green ‘Request’ lamp in the delegate unit in top of the queue will flash slowly indicating that this unit is the next to be switched ‘On’
The green ‘Request’ lamp in the other delegate unit in the queue will light up steadily.
When one of the units speaking is switched ‘Off’, the first delegate unit in the queue is automati‐ cally switched ‘On’.
This mode will normally be used with only 1 as
‘Max delegate speakers’. Chairman units will always be turned on directly if the value set for e
• VOX, voice activation mode allows for the conference units to be switched on automatically when a delegate is speaking in the microphone or by touching the ‘Speak’ button.
This is indicated by a red light in the ‘Speak’ lamp in the conference unit. Touching the microphone
‘Speak’ button again will turn the microphone off.
When a delegate stops speaking the microphone
(see section ‘5.6 Web Browser Setup and
The microphone can also be turned off by
touching the Speak’ button.
A Chairman Unit can be considered as always being in Auto or VOX mode
5.7.2 Delegate Interrupt Mode
The “Delegate Interrupt” setting determines the behavior of the delegate conference units.
If ‘Off’ is selected one delegate will not interrupt another. If “On” is selected a delegate is allowed to interrupt (switch off) another delegate. Interrupt becomes relevant when ‘Max Delegate Speakers’ get exceeded.
When this occur the delegate who has been ‘On’ for the longest time is interrupted (switched off) to give room for the interrupting delegate.
34 User Manual DDS 5900
Danish Interpretation Systems User Manual
6 DC 5980P Conference Unit
6.1 Overview
The Con ference Unit offers the following featu res:
• Conference unit can be configured as
Delegate, Chairman or Int erpretation Unit
• Touch button technology
• Lockable XLR microphone so cket
• Two channel interpretation
• Cat5e daisy ch ain connection of units
• Loudspeaker
•
•
Mute/All Del Off and Speak/Request butto
Channel selector with chann el indication
• Headphone volume con
• Headphone connector trol ns
1. Button panel – The button panel contains the controls available on the unit.
2. Headphone socket – Connection of headphone
DH 6021 or similar.
3. XLR socket for microphone – Used to connect a
DIS gooseneck microphone to the unit. The GM
59xx gooseneck microphone can be locked to the unit with a 1.5 mm hex/allen key. The lock is accessible from the small hole next to the XLR socket. Turn the hex key counter clockwise to lock the gooseneck microphone to the unit and turn the hex key clockwise to unlock the fr m the unit.
4. Loudspeaker – Built in loudspeaker. The loudspeaker is turned ‘Off’, when the microphone in the unit is active.
The built in loudspeaker is always ‘Off’ when the unit is configured as Inte rpreter Unit.
5. DCSLAN connection – Two RJ45 sockets are located at the bottom of the unit for connecting to the previous unit or to the CU 5905 Central Unit and to the next unit. A plastic cable clamp can be ordered separate and can be used to fix the cables if desired.
Figure 6.1-A DC 5980P Conference Unit
6.2 Preparing the conference unit
The units must be prepared before use. The following preparations have to be done:
•
• Configuring the unit to the required unit type.
6.2.1 Conference Unit Overlays
The following overlays are available as standard:
6.2.1.1 Delegate, ‘Speak’ & ‘Mute’ button
This overlay is delivered together with the conference
User Manual DDS 5900 35
Danish Interpretation Systems User Manual unit and offers a ‘Speak’ button and a ‘Mute’ button for muting own microphone.
6.2.1.2 Delegate, ‘Speak’ button
This overlay must be ordered separately and is NOT delivered with the conference unit. This overlay is used when the ‘Mute’ of own microphone is not required.
One sample is delivered together with the CU
5905.
Please refer to the section ‘9.6 Accessories ’.
6.2.1.3 Chairman
This overlay is used for Chairman unit functionality .
Two chairman overlay are delivered with CU 5905.
6.2.1.4 Interpreter
This overlay is to be used for Interpreter unit functionality.
Three interpreter overlay are delivered together with the CU 5905.
6.2.2 Other languages, CM & IS
Language packages are available for Chairman and
Interpreter overlay in other languages.
Please refer to the section ‘9.6 Accessories ’.
6.2.3 Attaching Overlays
The overlay is attached to the unit by removing the protection paper and placing the overlay in the overlay recess at the front of the unit.
The overlay is not designed to be removed from the unit after it has been attached to the unit.
Spare part package with overlays are available. Please refer to the section ‘9.6 Accessories ’.
6.2.4
Configuration of the unit
The unit is default configured as Delegate with ‘Speak’ and ‘Mute’ button.
Any unit can be re‐configured either as a chairman, delegate (without ‘Mute’ button) or interpreter unit.
To change unit type press the volume buttons ‘‐‘ and
‘+’ simultaneously and keep depressed for 3 seconds until the ‘Speak’ light starts flashing. Then use the channel button to toggle between unit type.
Unit type
Delegate with mute
Delegate without mute
Chairman
Interpreter
Figure 6.2-A Changing Unit Type
Ch. 1
Off
On
Off
On
Ch. 2
Off
Off
On
On
When the buttons are released, the light in the buttons will flash to indicate that the unit is configured and the unit will reboot.
The unit type is stored in the unit so the unit recalls its type if/when it is used with another CU 5905.
6.3 Delegate Unit
When the unit is configured as Delegate unit the buttons has the following functionality:
1. Headphone volume control – The ‘‐‘ button decreases the sound level in the connected
headphone and the ‘+’ button increases the sound level.
2. Mute button – Touching the ‘Mute‘ button mutes the sound from the microphone without switching off the unit as long as the button is activated. When muted, the red light ring on the microphone is turned off.
36 User Manual DDS 5900
Danish Interpretation Systems User Manual
3. Speak button – Touching the ‘Speak‘ button
turns the microphone ‘On’ or sets the user into
‘Request to Speak’ depending on the ‘System
Operation Mode’. Please refer to section ‘5.7
4. Language selection – Used to switch between
‘Floor’ language and ‘Ch.1’ and ‘Ch.2’ if
5. Language indication – ‘Ch.1’ selection is indicated with light in Led 1 and ‘Ch.2’ selection is indicated with light in Led 2. With no light the
‘Floor’ channel is selected.
6.4 Chairman Unit
When a unit is configured as a Chairman unit the buttons have the following functionality:
1. Headphone volume control – The ‘‐‘ button decreases the sound level in the connected headphone and the ‘+’ button increases the sound level.
2. Del. Off button – Touching the ‘Del. Off‘ button switched of all delegate microphones.
6.5 Interpreter Unit
When the unit is configured as Interpreter unit the buttons has the following functionality:
3. Speak button – Touching the ‘Speak‘ button turns the microphone ‘On’.
4. Language selection –Switch between ‘Floor’ language and ‘Ch.1’ and ‘Ch.2’ if interpreter units are connected.
5. Language indication – ‘Ch.1’ selection is indicated with light in Led 1 and ‘Ch.2’ selection is indicated with light in Led 2. With no light the
‘Floor’ channel is selected.
1. Headphone volume control – The ‘‐‘ button decreases the sound level in the connected headphone and the ‘+’ button increases the sound level. The sound in the headphone will always be the ‘Floor’ sound when the unit is configured as
Interpreter unit.
2. Mute button – Touching the ‘Mute‘ button mute the sound from the microphone without switching off the unit as long as the button is activated. When muted, the red light ring on the microphone is turned off.
3. Speak button – Touching the ‘Speak‘ button turn the microphone ‘On’ and deliver audio to the selected interpreter channel. Any other interpreter unit interpreting on the same channel will be turned off.
4. Interpreter channel – Used for switching the
‘Out‐going‘ interpreter channel between ‘Ch.1’ and ‘Ch.2’. Audio from the microphone is send to the selected interpreter channel.
5. Outgoing language indication – ‘Ch.1’ selection is indicated with light in Led 1 and ‘Ch.2’ selection is indicated with light in Led 2.
User Manual DDS 5900 37
Danish Interpretation Systems User Manual
7 GM 59xx Gooseneck Microphones
The gooseneck microphones series GM 59xx are delivered in two lengths: 40 cm and 50 cm. The
Gooseneck microphone features a red light ring, which light up, when sound from the unit is send to the central unit.
T m he microphone is inserted in the XLR socket in the icrophone and can be locked to the unit with a 1.5 mm hex/allen key. The lock is accessible from the small hole close to the XLR socket. Turn the hex key counter clockwise to lock the gooseneck microphone to the unit. Turn the hex key clockwise to unlock the gooseneck microphone from the unit.
38 User Manual DDS 5900
Danish Interpretation Systems User Manual
8 Troubleshooting
In this chapter a simple fault‐finding guide is given.
This is intended to be used to remedy the consequences of incorrect installation. If more serious faults or problems a rise the installer should contact a qualifie d tech nician.
The light rings in the microphone in the units are constantly flashing
Check the cables as the digital communication from the central unit to the conference units is not established.
Check that all the connectors on all cable are firmly inserted in the socket on th e unit s
Check that the feeding cables from the conference units are inserted in the ‘DCS‐LAN’ socket on the CU 5905.
The ‘Dell Off’ button in the chairman unit does not switch off delegate units
The sound from an interpreter unit cannot be heard in the headphone in delegate or chairman units
Check if the unit is configured as a chairman unit
Check if the unit is configured as an interpreter unit. Please refer
to section ‘6.2.4 Configuration of the unit’.
Check the headphone volume control on the units
c nce units
Check the plug from the headphone is firmly inserted in the headphone socket
Check that the light ring on the microphone on the interpreter unit is lighting and that he gooseneck microphone is firmly
There is no sound in the built‐in loudspeakers
The is no sound in the built‐in loudspeakers from one or more delegate or chairman units
A microphone cannot be turned ‘On’
Check the ‘Loudspeaker Volume’ setting using either the interactive menu on the CU or using the browser control.
Check using the browser control that the setting ‘CU 5905 Setup *
Audio * Loudspeaker Control * Microphone ‐> Loudspeaker’ is set to ‘On’.
Check using the browser control the settings in ‘CU 5905 * Audio *
Audio Output * Group Setup‘ that the seats are selected in ‘Group
A’. ‘Group A’ is always used as the source for the built‐in loudspeakers. If a unit is not selected in ‘Group A’ the sound from this unit will not be heard in the built‐in loudspeakers.
Check using the browser control in ‘CU 5905 * Audio * Audio
Output * Group Setup‘ that this seat is selected in ‘Group A’.
‘Group A’ is always used as the source for the built‐in loudspeakers. If a unit is not selected in ‘Group A’ the sound from this unit will not be heard in the built‐in loudspeakers.
Check the settings ‘Max Delegate Speaker’ and ‘Max Total
User Manual DDS 5900 39
Danish Interpretation Systems User Manual
The CU 5905 browser application will not open in a PC or iPad
The CU 5905 browser application will not open in iPad
Speakers’.
Check the ‘Operation Mode’.
Check the IP address using the interactive menu on the CU: ‘LAN setup/IP address setup/IP address’. Use this IP address in the browser
Check that the CU 5905 is connected to the same network as the
PC
Check the LAN cables
Check the IP address using the interactive menu on the CU: ‘LAN setup * IP address setup * IP address’. Use this IP address in the browser.
Check that the iPad is connected to the correct wireless access point
Check that the CU 5905 is connected to the same network as the wireless access point
40 User Manual DDS 5900
Danish Interpretation Systems User Manual
9 Technical Specifications
9.1 System Specification
Overall system characteristics
The microphone system conforms to IEC 60914, the international standard for conference systems. However the functionality of an interpreter unit differs from the standard.
Sound quality .....24 bit audio @ 32 kHz sampling frequency
Measured from the audio input of a conference unit to the headphone output of a conference unit:
Audio frequency response ......................65 Hz ‐ 16 kHz (‐3 dB)
Total harmonic distortion at 1 kHz ....................................< 0.1%
Dynamic range ...........................................................................> 80 dB
Weighted signal‐to‐noise ratio ....................................> 85 dB(A)
Cabling and System Limits
Cable type (min. specification) .......Cat5e, AWG 24, screened
Maximum cable length in one chain ................................... 150 m
System Environmental Conditions
Working condition .......................................... Fixed, stationary or
transportable
9.2 CU 5905 Specifications
Analog Section
Audio output signal type ........................electronically balanced
Nominal output level ..............................0 dBm at nominal input
Max. output level............................................ 4.9V RMS ∼ +16 dBm
Audio input signal type ...........................electronically balanced
Nominal input level (In 1 is switchable).........................................
....................... 0 dBm or ‐10 dBm (0.775V RMS or 0.245V RMS)
Max. input level ............................................. +15 dBm (4.5V RMS)
Analog Audio in impedance ......................................50‐100 kohm
Connectors
Chain – Conference units (DCS‐LAN) .................................2xRJ45
Temperature range
To guarantee specified performance...... 5 Deg C. to 40 Deg C.
Storage temperature .................................. ‐20 Deg C. to 60 Deg C
Maximum relative humidity ...................................................< 80%
Approvals
EMC emission According to harmonized standard EN 55103‐1 and
FCC rules part 15, complying with the limits for a class A digital devices
EMC immunity According to harmonized standard EN 55103‐2
Affixed with the CE mark EMC a pprovals
ESD
Mains harmonics
According to harmonized standard EN 55 3‐2
According to harmonized standard EN 5510 3‐1
Environmental requirements Contains no banned substances as specified in
UAT‐0480/100 (e.g. no cadmium or asbestos)
Specifications are subject to change without notice
Maximum total number of units to be connected to both outputs on a CU 5905:
DC 5980P Conference Units ................................. up to 60 pieces
Audio output............................... 4 pieces XLR3 male connectors
Audio input.................................2 pieces XLR3 female connector
LAN (TCP/IP) ....................................................................1 piece RJ45
EEM.................................................................. 1 contact closure input
General
Default IP address ......................................................... 192.168.10.1
Power consumption............................................... max. 150W/48V
Supply voltage for DC 5980 units ............................... 125W/48V
User Manual DDS 5900 41
Danish Interpretation Systems User Manual
Weight............................................................................................... 2.8 kg
Dimensions (W x H x D)..................427 (483) x 44 .4 x 186 mm
Dimension in bracket is including 19” brackets
System performance
Max. number of conference units ..............................................250
Max. number of interpreter units................................................. 32
Max. number of languages.................................................................. 2
Max number of open microphones................................................. 8
Accessories supplied
•
•
CU 5900 External Power Supply incl. mains cable
• Terminal block for EEM connector b
t
• USB memory stick with ‘User Manual’
• DC 5980 Button Overlays: Chairman (English, 2 pieces), Interpreter (English, 2 pieces) and Delega te –
Speak (Pictogram, 1 piece)
• Tool for fixing the GM 59xx Gooseneck Microphone
9.3 DC 5980P Conference Unit
CU 5900 Externa l Power Supply
Delivered pow er max. 150W
Input current
In‐rush current max . 4A@115V AC or max. 2A@230V AC max. 40A@115V or max. 20A@230V
Standby consumption................................................................ <0,5W
Mains voltage .................................................100 ‐ 240V, 50 ‐ 60Hz
Supply voltage for CU 5905.................................................. 48V/3A
Efficiency typical………………………………………………………..87%
Weight................................................................................................ 935 g
Dimensions (W x H x D).....................................180 x 52 x 99 mm
Approvals .......................................................... CE, KC, CCC, UL, TÜV
Specifications are subject to change without notice
Digital Section
Loudspeaker frequency range........................... 150 Hz – 15 kHz
Loudspeaker maximum power ......................................2,1W RMS
General
Power requirement...........................................................24‐48 V DC
Power consumption............................................................ 1W to 3W
Power supplied from CU 5905 / EX 6010 / PS 6000
Weight................................................................................................ 500 g
Dimensions (W x H x D).................................. 128 x 71 x 146 mm
Colour..................................................................................................Black
9.4 GM 59xx Gooseneck Microphones
Connectors
DCS‐LAN loop through................................................ 2 pieces RJ45
Headphone................................................. 3.5 mm Stereo Jack plug
XLR for GM 65xx or GM 59xx type ...........................XLR3 female
Acce
• Button overlay, Delegate with ‘Speak’ and ‘Mute’ button
Specifications are subject to change without notice.
General
Transducer type...................................................................Condenser
Polar pattern .............................................................................. Cardiod
Frequency response...................................................30 Hz ‐ 18 kHz
Sensitivity............................. ‐52 +/‐ 3dB (0dB = 1V/1Pa, 1 kHz)
M aximum input sound level ....110 dB SPL, 1 kHz at 3% THD
Signal‐to‐noise ratio...............................................................>60 dBA
Front/back ratio ........................................................ >25 dB (1 kHz)
Dimension (GM 5923).......................................................... 400 mm
Dimension (GM 5924).......................................................... 500 mm
Microphone connector......................................................XLR3 male
Specifications are subject to change without notice.
42 User Manual DDS 5900
Danish Interpretation Systems User Manual
9.5 Connection Details
Mains
Blue
Brown
Neutral
Live
Green/Yellow Earth (Ground)
Chain (DCSLAN)
The DDS 5900 system uses Cat5e, Cat6 or Cat7 F/UTP or U/FTP cables with screened R J45 connectors.
EIA 568‐B wiring shall be used.
Important: The names of Cat5/6/7 cable type have changed.
Old name
FTP
STP
UTP
New name
F/UTP
U/FTP
U/UTP
Important: Use only F/UTP or U/FTP (screened) cables and screened RJ45 connectors and not U/UTP cable, which are unscreened.
How to wire a Cat5e (EIA 568‐B) cable to a RJ45 con.:
7
8
5
6
Pin Function
1 Ingoing +
2
3
4
Ingoing
+48V
0V
0V
+48V
Outgoing
Outgoing +
Connector #1
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
Connector #2
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
Note: If other color codes are used then the four e c as follows:
Pair 2: Pin 1 & 2
Pair 3: Pin 3 & 6
Pair 1: Pin 4 & 5
Pair 4: Pin 7 & 8
The phase of the pairs must be correct and the wiring spec. as stated in Cat5e (EIA 568‐B) have to be followed.
Note: Cat6 and Cat7 cables can normally only be c e
Cat6 and Cat7 can thus only be used for feeding cables terminating in wall outlets or patch panels.
Analog Audio Out
XLR3 male
Pin
1
2
3
Signal
Earth
Signal +
Signal –
Cable type
2 x 0.25 mm2 shielded.
Analog Audio In
XLR3 female
Pin
1
2
3
Signal
Earth
Signal +
Signal –
Cable type
2 x 0.25 mm2 shielded.
Emergency switch
Terminal block
Connect the emergency switch to pin 1 and 2.
User Manual DDS 5900 43
Danish Interpretation Systems User Manual
Earphones
3.5 mm Jack plug
Pin
1
2
3
Connector
Tip
Ring
Sleeve
Function
Signal left
Signal Right
Electrical earth/screen
9.6 Accessories
Gooseneck Microphones
GM 5923 Gooseneck Microphone, 40 cm..............18 12 05910
GM 5924 Gooseneck Microphone, 50 cm..............18 12 05920
GM 6523 Gooseneck Microphone, 40 cm..............18 12 05714
GM 6524 Gooseneck Microphone, 50 cm..............18 12 05716
GM 6525 Gooseneck Microphone, 63 cm..............18 12 05718
GM 6622 Shotgun Gooseneck Mic. 29.5 cm..........18 12 05822
Cat5e Connection Cables (AWG24)
EC 6001‐0.5 Connection Cable 0.5 m......................10 03 22500
EC 6001‐01 Connection Cable 1 m...........................10 03 23101
EC 6001‐02 Connection Cable 2 m...........................10 03 23201
EC 6001‐05 Connection Cable 5 m...........................10 03 23501
EC 6001‐10 Connection Cable 10 m........................10 03 24102
EC 6001‐20 Connection Cable 20 m........................10 03 24202
EC 6001‐50 Connection Cable 50 m........................10 03 24502
Cable Clamp
AC 5900 Cable Clamp, 100 pieces ............................15 12 61101
The clamp will prevent the cable getting stuck between the table and the bottom of the unit, if the unit is moved
Transportation and Storage Box
SB 5980 Storage Box for 10 DC 5980P & GM .... 15 12 61001
Headphones
DH 6021 Stereo headphones .................................... 14 11 03055
Expansion units
JB 6104 Junction Box with 4 outputs..................... 15 09 05797
EX 6010 Extension Unit............................................... 15 09 05681
PS 6000 Power Supply ................................................ 15 09 05756
RP 6004 Repeater/Splitter for four chains ......... 15 09 05757
Button Overlay Packs
DC 5 1 6
Chairman and Interpreter overlays (one of each) in the following languages:
Spanish, Russian, French, Portuguese
DC 5 1 6
Chairman and Interpreter overlays (one of each) in the following languages:
Chinese‐simple, Chinese–traditional, Arabic, Farsi
DC 5980P Overlay Delegate ....................................... 15 12 60905
Delegate overlay, Pictogram, without ‘Mute’ button, 10 pieces.
44 User Manual DDS 5900
Danish Interpretation Systems User Manual
10 External Control Application Protocol
The DDS 5900 Digital Conference System features an
Ethernet connection with the purpose of providing an interface for controlling and monitoring of the system. By setting up a simple (raw) TCP/IP socket connection to the CU 5905 Central Unit control options are available.
This document describes the TCP/IP raw socket protocol for communicating with the DDS 5900
Microphone System. This protocol provides a short set of commands, enabling a third part control application to monitor and/or control system status of a DDS 5900 Microphone System.
Some examples of functionally available using the protocol:
• Setting a microphone in speak or in request
• Retrieving a list of seats available in the system.
This interface supports applications developed by customers, so the protocol is deliberately kept simple to avoid complexity. The external control application protocol offers a mean for supplementing the control functionality available through the DDS 5900 Web interface and the CU 5905 display, however some commands and settings available in the web interface and on the CU 5905 interactive display are not available using the ‘External Control Application
Protocol’
Customer applications can include but are not limited to AMX ® or Crestron ® room control systems, PC or micro controller based applications e.g. for button mimics and camera control applications.
10.1 General Protocol behaviour
10.1.1 TCP/IP socket connection
A TCP/IP socket connection to the CU 5905 must be established for the external control application protocol to become available. Configuration of the CU 5905 connection to the Ethernet must be defined from the CU interactive front plate control/WEB interface, and an IP address for the CU 5905 must be assigned in the network.
Choose either a static IP address or an IP address assigned through DHCP. It is convenient to ensure, that the CU
5905 ends up with the same IP address at each start up.
Knowing the IP address, the only additional information required for setting up a TCP/IP connection is the Port
Number:
Port Number = 3142
Example: Test connection to CU via Putty:
If the CU 5905 is assigned IP address 192.168.1.100, the external application must connect the TCP/IP socket to the address 192.168.1.100:3142.
a connection can be set up using a simple terminal program like Putty ®.
1. Download at www.putty.org
2. Start Putty.
3. Insert IP address and Port Number.
4. Select ‘Raw’ for the Connection Type.
5. Press ‘Open’ to establish connection to the CU. Control is now possible.
User Manual DDS 5900 45
Danish Interpretation Systems User Manual
6. Give command ‘help’ to see a list of commands available.
10.1.2 Command structure (from External Control to CU 5905)
To control the CU an external control application sends commands to CU 5905 included in command lines.
Commands lines are build up in a very simple manner:
<command><SP><data><CR>
<command><SP><data><LF>
<SP> Space ‐ 0x20 = 32
<CR>
<LF>
Carriage return ‐ 0x0D = 13
Line Feed ‐ 0x0A = 10
Command lines are terminated by Carriage Return <CR> or Line Feed <LF> or both. In order to be able to communicate with Windows systems, Linux systems or other systems, the CU understands both types of command line terminations.
Notice also, there is a space between the command and data. If a command does not carry any data, space is possible but not required.
The CU is not sensitive to upper/lower case.
Example: mic_on 212<CR>
Turn on microphone a seat 212. Command = 'mic_on', data = '212'. The ‘mic_on’ command carries a seat number as data.
10.1.3 Command structure (from CU 5905 to External Control)
Command lines out of the CU 5905 are just as simple:
<command><SP><data><CR><LF>
<SP>
<CR>
<LF>
Space ‐ 0x20 = 32
Carriage return ‐ 0x0D = 13
Line Feed ‐ 0x0A = 10
Again, to satisfy most systems, the CU terminates command lines by including both <CR> and <LF>.
46 User Manual DDS 5900
Danish Interpretation Systems User Manual
10.1.4 Seat numbering
Conference units are identified by means of a seat numbers. Each conference unit is assigned a seat number. This is done automatically for all conference units, when they are connected to the CU 5905. The CU 5905 WEB interface is used to change seat numbering.
Seat numbers must be in the range from 1 to 65535.
10.1.5 CU 5905 reply to commands
Generally, a command from external application is replied to by the CU. But, reply to a command is produced only if actions are taken by the CU due to the command.
Example: When a ‘mic_on’ command results in a microphone being turned on, the CU replies with a ‘mic_on’ command. On the other hand, if a 'mic_on' command does not lead to turning on a microphone, the CU does not produce any reply.
There can be several reasons for the CU to reject turning on a microphone:
‐The microphone is already turned on
‐The microphone is no longer connected to the system.
‐Speak list is already full (‘max_speakers’), and delegate interrupt is not ‘on’.
10.1.6 Retrieving system status
The CU supports streaming of status. When an external control application issues a ‘mic_status’ or ‘audio_status’ command, the CU responds by sending the microphone system status. The same goes for ‘audio status’. Hereby, it is possible for an external control application to synchronize with the CU status.
10.2 Microphone Control
10.2.1 Commands from External Control to CU 5905
10.2.1.1 Turn on microphone
mic_on <seat no><CR>
Instruct the CU to turn on microphone at seat_no.
If the CU turns on the microphone, it will reply with a ‘mic_on’ command. And, if the microphone appeared in the r equest list, it is taken out of the request list, which makes the CU issue a ‘mic_request_off’ command as well.
10.2.1.2 Turn off microphone mic_off <seat no><CR>
Instruct the CU to turn off microphone at seat_no.
I f the CU turns off the microphone, it replies with a ‘mic_off’ command.
User Manual DDS 5900 47
Danish Interpretation Systems User Manual
10.2.1.3 Turn off all delegate microphones mic_all_delegates_off<CR>
Instruct the CU to turn off all d elegate microphones.
A Chairman is not turned off.
T he CU responds to the command by issuing a ‘mic_off’ command for each microphone which is turned off.
10.2.1.4 Put microphone in request list
mic_request_on <seat no><CR>
Insert microphone into request list.
I f the CU inserts the unit into the request list, it replies with a ‘mic_request_on’ command.
10.2.1.5 Remove microphone from request list
mic_request_off <seat no><CR>
Remove microphone from request list.
I f the CU removes the unit from the request list, it replies with a ‘mic_request_off’ command.
10.2.1.6 Clear request list
mic_all_requests_off<CR>
Clear the request list. l
The CU responds by issuing a ‘mic_request_off’ command for each microphone that is removed from the request ist.
10.2.1.7 Set next microphone on mic_next_on<CR>
Turns off first microphone in the speak list, an d turns on first mic rophone from the request list.
If a microphone is turned off, the CU sends a ‘ mic_off ’ command.
I f a microphone is turned on, the CU sends a ‘mic_on’ command and a ‘mic_request_off’ command.
10.2.1.8 Set max total speakers max_total_speakers <max total speakers ><CR>
Maximum number of sp eakers allowed to speak .
<max total speakers> Can be set to “1” to “8”
T he CU responds by sending a ‘max_total_speakers’ command.
48 User Manual DDS 5900
Danish Interpretation Systems User Manual
10.2.1.9 Set max delegate speakers max_speakers <max speakers><CR>
Maximum number of delegates allowed to speak.
<max speakers> Can be set to “1” to “8”
T he CU responds by sending a 'max_speakers' command.
10.2.1.10 Set max requests
max_requests <max requests><CR>
Maximum numbe r of delegates allowed in th e request list.
<max requests> Can be set to “ 0” to “250”.
T he CU responds by sending a 'max_requests’ command.
10.2.1.11 Set operation mode mic_mode <mode><CR>
Se t syst em operation mode.
<mode> Can be set to “auto” (A utomatic), “fifo” (First‐ in‐first‐out), “manual” (Manual) and “vox” (Voice Active)
T he CU responds by sending a ‘mic_mode’ command.
10.2.1.12 Set interrupt mode mic_interrupt <mode><CR>
Se t abil ity to interrupt. Defines, whether microphones should interrupt or not.
<mode> Can be “on” (microph ones interrupt ) and “off” (m icrophones do not interrupt)
T he CU responds by sending a ‘mic_interrupt’ command
10.2.1.13 Retrieve microphone status mic_status<CR>
Ask the cu to deliver status of the system (microphones in speak, and microphones in request list).
The CU responds by se nding microphone system status. Th e status is a list of commands from the CU:
seat_number (for all microphones in the system) mic_mode mic_interrupt max_total_speakers max_speakers max_requests
User Manual DDS 5900 49
Danish Interpretation Systems User Manual
mic_on (for all microphones on)
mic_request_on (for all microphones in request list)
mic_status_done
10.2.1.14 Help help<CR>
Help information is available listing all commands supported by the CU. If a command is included in the help comm and, details on that command is returned.
Note: The help command results in a number of command lines returned from the CU. The command is intended for use in a simple console.
10.2.2 Commands from CU 5905 to External Control
10.2.2.1 Microphone on mic_on <seat no><CR>
A microphone is turned on.
10.2.2.2 Microphone off mic_off <seat no><CR>
A microphone is turned off.
10.2.2.3 Microphone in request list mic_request_on <seat no> <request position><CR>
A microphone is in serted into request list.
< request position> informs about the position in the request list.
10.2.2.4 Microphone out of request list mic_request_off <seat no><CR>
A microphone is removed from request list.
10.2.2.5 Max total speakers max_total_speakers <max total speakers ><CR>
M aximum number of speakers allo wed to speak.
<max total speakers> "1" to "8"
50 User Manual DDS 5900
Danish Interpretation Systems User Manual
10.2.2.6 Max delegate speakers max_speakers <max speakers><CR>
M aximum numb er of delega tes allowed to speak.
< max speakers> "1" to "8"
10.2.2.7 Max requests max_requests <max requests><CR>
M aximum number of delegates allowed in the request list.
< max requests> "0" to "250".
10.2.2.8 Operation mode mic_mode <mode><CR>
Sy stem operation mode.
< mode> "auto" (Automatic), "fifo" (First‐in‐first‐out), "manual" (Manual) and "vox" (Voice Active)
10.2.2.9 Interrupt mode mic_interrupt <mode><CR>
A bility for microphones to interrupt.
< mode> "on" (microphones interrupt) and "off" (microphones do not interrupt)
10.2.2.10 Seat Number seat_number <seat number> <seat state> <seat name><CR>
Seat information.
This information is sent from the CU to an external control application, when the external control application re quests micro phone status (mic_status).
< seat num ber> The seat number identification of a conference unit. An inte ger ranging from 1 to 65535.
< seat state> The current state of the seat. This can be “active” or “passive ”
<seat name> Name assigned to a conference unit via the WEB interface.
Example: seat_number 12 active Barack Obama<CR>
This command informs about seat number 12, which is active and has the name Barack Obama attached.
User Manual DDS 5900 51
Danish Interpretation Systems User Manual
10.2.2.11 Microphone status complete mic_status_done<CR>
I nforms, that complete system status has been sent.
10.2.2.12 Seat state seat_state <seat number> <seat state><CR>
Seat state information.
This information is sent from the CU to an external control application, when the state of a seat changes – a seat b ecomes passi ve or active.
< seat num ber> The seat number identification of a conference unit. An inte ger ranging from 1 to 65535.
< seat state> The current state of the seat. This can be "active" or "passive"
10.2.2.13 Command error command_error <error text><CR>
The CU has received an unknown command.
<error text> is a text explaining the fault case.
Examples: command_error unknown command<CR> command_error syntax error<CR>
10.3 Audio Control
10.3.1 Commands from External Control to CU 5905
10.3.1.1 Set loudspeaker volume loudspeaker_volume <volume><CR>
Se t the vo lume of loudspeakers for all conference units.
<volume> The volume of the loudspeakers ranging from ‐41 to 0. The value ‐41 indicates Off, whereas values from ‐
40 to 0 indicates attenuation in dB.
T he CU responds to this command by returning a ‘loudspeaker_volume’ command.
10.3.1.2 Set line input 1 level line_input_level_1 <level><C R>
Adjust the level of line input signal.
52 User Manual DDS 5900
Danish Interpretation Systems User Manual
<level> The level of line input 1 ranges from ‐41 to 0. The value ‐41 indicates Off, whereas values from ‐40 to 0 indicates attenuation in dB.
T he CU responds to this command by returning a ‘line_input_level_1’ command.
10.3.1.3 Set line output volume (A-D) line_output_volume <output> < volume><CR>
Adjust the level of line output signal.
< output> Indicates which output is being controlled. Possible values: ‘A’, ‘B’, ‘C’, ‘D’.
<volume> The volume of line output ranges from ‐41 to 0. The value ‐41 indicates Off, whereas values from ‐40 to 0 indicates attenuation in dB.
T he CU responds to this command by returning a 'line_output_volume' command.
10.3.1.4 Define audio path audio_path <path> <on/off><CR>
T his comm s t
<path> Indicates which connection is being controlled. Possible values: 'mic_to_speaker', 'mic_to_floor',
'li nein_1 _to_speaker', 'linein_1_to_lineout_A', ‘linein_1_to_floor’.
<on/off> Indicates, whether the audio is being rout ed from mic rophones/li neinput_1 to speakers/lineoutput/floor.
T he CU responds to this command by returning an ‘audio_path’ command.
10.3.1.5 Request audio status audio_status<CR>
System audio status.
T he CU responds to this command by returning a list of commands for the Audio settings: loudspeaker_volume line_output _volume (for a
audio_path (for all paths) ll outputs A‐D) line_input_level audio_status_done
10.3.2 Commands from CU 5905 to External Control
10.3.2.1 Loudspeaker volume loudspeaker_volume <volume><CR>
Volume of loudspeakers for all conference units.
User Manual DDS 5900 53
Danish Interpretation Systems User Manual
<volume> The volume of the loudspeakers ranging from ‐41 to 0. The value ‐41 indicates Off, whereas values from ‐
4 0 to 0 indicates attenuation in dB.
10.3.2.2 Line input 1 level line_input_level_1 <le vel><CR>
Le vel o f line input 1 signal. i
<level> The level of line input 1 ranges from ‐41 to 0. The value ‐41 indicates Off, whereas values from ‐40 to 0 ndicates attenuation in dB.
10.3.2.3 Line output level (A-D) line_output_level <output> <level><CR>
Adjust the level of line output signal.
< outp ut> Indicates which output is being controlled. Possible values: ‘A’, ‘B’, ‘C’, ‘D’.
i
<level> The level of line output ranges from ‐41 to 0. The value ‐41 indicates Off, whereas values from ‐40 to 0 ndicates attenuation in dB.
10.3.2.4 Define audio path audio_path <path> <on/off><CR>
T his comm s t t
<path> Indicates which connection is being controlled. Possible values: 'mic_to_speaker', 'mic_to_floor',
'li nein_1 _to_speaker', 'linein_1_to_lineout_A', ‘linein_1_to_floor’.
<on/off> Indicates, whether the audio is being routed from microphones/lineinput_1 to s peakers/lineoutput_A/floor.
10.3.2.5 Audio status complete audio_status_done<CR>
T his command terminates audio status streaming.
54 User Manual DDS 5900
İndir
Reklam