CADEM Viking - 100 Machine Control System Settings Guide
PDF
Документ
Реклама
Реклама
Viking - 100 NCnet 7.0 settings Set these parameters on the machine Baud rate Parity = 2400 = Even To set the controller in the Drip-feed mode Drip feed is not available on this controller. Set these parameters on the PC Machine details Machine name Control system Machine ID Communication Channel Port Number Folder for PC to Machine transfer Folder for Machine to PC transfer Baud rate Data bits Parity Stop bits Handshake MCH-1 Viking - 100 01 Serial Port Any free COM port) Transmit directory Receive directory 2400 7 Even 2 Hardware General settings Ignore this. Leave all data as it is. Transmit settings Wait period at start of transmission Wait period after transmitting program Size of transmit packet Delay period after each packet Wait for XON before transmitting program Transmit comments? Comment start character Comment end character Translation mode for CR Translation mode for LF Acknowledgement and error (Mode of transmission) ACK/ERR Message start text ACK/ERR Message start text Filter Null Character 30.00 5.0 0 0 No Yes ( ) Transmit as CR Transmit as LF Transmit descriptive message %1234 % Yes Page 1 of 2 NC Program settings Program start string Program end string Characters to transmit at start Characters to transmit at start Number of Characters Number of Characters Receive settings Wait period before receiving program Wait period after receiving program Transmit XON before transmitting program Auto compare and save Acknowledgements and errors Translation mode for CR Translation mode for LF Ignore control characters other than CR-LF Save Program between Start Characters and End Characters Start Program reception after these characters are received End Program reception after these characters are received 45.0 5.0 No Yes Transmit descriptive messages Ignore Save as CRLF Yes No To set the PC in the Drip-feed mode Drip feed is not available on this controller. Cable connections If the PC has 9 pin connector Null modem PC 9 pin Full Handshake CNC 25 pin 1 2 3 4 5 6 7 8 8 2 3 20 7 6 4 5 PC 9 pin CNC 25 pin 1 2 3 4 5 6 7 8 8 2 3 6 7 20 5 4 If the PC has 25 pin connector Null modem PC 25 pin 8 2 3 20 7 6 4 5 CNC 25 pin 8 3 2 20 7 6 4 5 Full Handshake PC 25 pin 8 2 3 20 7 6 4 5 CNC 25 pin 8 3 2 6 7 20 5 4 Note: There is no standard cable configuration for this controller. Please refer the machine user manual Page 2 of 2 ">
/
Скачать
Просто дружеское напоминание. Вы можете просмотреть документ прямо здесь. Но самое главное, наш ИИ уже прочитал его. Он может объяснить сложные вещи простыми словами, ответить на ваши вопросы на любом языке и помочь вам быстро перемещаться даже по самым длинным или сложным документам.
Реклама