Kongsberg Simrad SY50 Installation Manual
PDF
سند
تبلیغات
تبلیغات
INSTALLATION MANUAL Simrad SY50 kongsberg.com/simrad Simrad SY50 Fish-finding sonar Installation Manual The purpose of this manual is to provide the information, procedures and basic drawings required for the physical installation of the Simrad SY50 system. The manual is intended for technical personnel; such as skilled shipyard workers, electricians, qualified engineers and naval architects. For information about the practical use of the SY50 system, refer to the Reference Manual and/or the Operator Manual. You can also find information in the Context Sensitive On-line Help. Caution You must never permit the SY50 system to transmit (ping) when the ship is in dry dock. The transducers may be damaged if they transmit in open air. Additional end-user documents related to the SY50 system can be found on our website. This includes publications that are translated to other languages. Selected publications are also provided on IETM (Interactive Electronic Technical Manual) formats. • https://www.kongsberg.com/sy50 467020/B January 2022 © Kongsberg Maritime AS Document information • Product: Simrad SY50 • Document: Installation Manual • Document part number: 467020 • Document ISBN number: 978-82-8066-209-5 • Revision: B • Date of issue: 18 January 2022 Copyright The information contained in this document remains the sole property of Kongsberg Maritime AS. No part of this document may be copied or reproduced in any form or by any means, and the information contained within it is not to be communicated to a third party, without the prior written consent of Kongsberg Maritime AS. Warning The equipment to which this manual applies must only be used for the purpose for which it was designed. Improper use or maintenance may cause damage to the equipment and/or injury to personnel. You must be familiar with the contents of the appropriate manuals before attempting to operate or work on the equipment. Kongsberg Maritime disclaims any responsibility for damage or injury caused by improper installation, use or maintenance of the equipment. Disclaimer Kongsberg Maritime AS endeavours to ensure that all information in this document is correct and fairly stated, but does not accept liability for any errors or omissions. Support information If you require maintenance or repair, contact your local dealer. You can also contact us using the following address: [email protected]. If you need information about our other products, visit https://www.kongsberg.com/simrad. On this website you will also find a list of our dealers and distributors. Kongsberg Maritime AS www.kongsberg.com Installation Manual Table of contents ABOUT THIS MANUAL ............................................................ 11 SIMRAD SY50 ........................................................................ 13 Important..........................................................................................................................14 System description ...........................................................................................................16 System diagram................................................................................................................18 System units .....................................................................................................................19 Display....................................................................................................................19 Processor Unit ........................................................................................................20 Power Supply Unit .................................................................................................20 Hull Unit.................................................................................................................21 Transducer ..............................................................................................................22 Installation trunk.....................................................................................................23 Additional required and optional items............................................................................25 Installation trunk.....................................................................................................25 Speed log ................................................................................................................26 Course gyro ............................................................................................................26 Uninterruptible power supply (UPS)......................................................................27 Operating Panel ......................................................................................................27 Global positioning system (GPS) ...........................................................................28 Scope of supply................................................................................................................29 General safety rules..........................................................................................................30 Installation requirements..................................................................................................32 Supply voltage requirements ..................................................................................32 Uninterruptible power supply (UPS) requirements................................................32 Cables and wiring requirements .............................................................................33 Compass deviation requirements............................................................................33 Noise sources..........................................................................................................34 Dry docking requirements ......................................................................................34 Requirement for classification approval.................................................................35 Network security..............................................................................................................35 Support information .........................................................................................................36 PREPARATIONS ..................................................................... 39 Installation summary........................................................................................................40 General safety rules..........................................................................................................42 About installation drawings .............................................................................................43 Tools, equipment and consumables required for installation...........................................44 Personnel qualifications ...................................................................................................44 467020/B 3 Simrad SY50 Rules for transducer handling ..........................................................................................45 Choosing the best location for the hull unit .....................................................................47 About the hull unit location....................................................................................47 Defining the fore and aft location of the hull unit ..................................................48 Defining the athwartships location of the hull unit ................................................48 Important considerations related to noise...............................................................49 Sonar room requirements.................................................................................................50 About the sonar room .............................................................................................50 Environmental requirements ..................................................................................50 Requirements for watertight integrity ....................................................................51 Size and access requirements .................................................................................51 Requirements for insulation, heating and ventilation.............................................52 Requirements for electrical installations, cables and communication ...................53 Requirements for bilge pump and decking.............................................................54 Lifting requirements ...............................................................................................54 Acoustic noise..................................................................................................................56 Introduction to the acoustic noise challenge ..........................................................56 Contributing factors................................................................................................56 Self noise ................................................................................................................58 Ambient noise.........................................................................................................60 Electrical self noise ................................................................................................61 Reverberation .........................................................................................................61 Some means to reduce acoustic noise ....................................................................62 INSTALLING THE SY50 SYSTEM HARDWARE UNITS............... 64 General safety rules..........................................................................................................65 Installing the display ........................................................................................................66 Installing the Nexcom NISE 3900E Processor Unit ........................................................67 Installing the Operating Panel (Mk2) ..............................................................................69 Installing the Operating Panel (Mk3) ..............................................................................71 Installing the Power Supply Unit.....................................................................................72 MOUNTING THE INSTALLATION TRUNK................................. 75 Installation summary........................................................................................................76 About the installation trunk .............................................................................................78 Rubber gasket .........................................................................................................78 Mechanical support brackets ..................................................................................79 Design and installation drawings ...........................................................................80 Length of transducer shaft versus height of installation trunk ...............................80 Mounting the installation trunk........................................................................................83 Verifying the quality of the installation ...........................................................................85 INSTALLING THE HULL UNIT ................................................. 88 4 467020/B Installation Manual Installation summary........................................................................................................89 General safety rules..........................................................................................................91 Hull unit familiarization...................................................................................................93 About the hull unit installation ........................................................................................94 Rubber gasket .........................................................................................................94 Design and installation drawings ...........................................................................95 Length of transducer shaft versus height of installation trunk ...............................95 Rotating the mounting flange on the installation trunk ..........................................97 Installation procedures ...................................................................................................100 Unpacking the hull unit from its transport box ....................................................101 Unpacking the transducer from its transport crate ...............................................102 Cutting the transducer shaft..................................................................................103 Making recesses for the set screws used to mount the cable gland assembly ..........................................................................................................105 Mounting the transducer flange ............................................................................106 Mounting the trunk bearing ..................................................................................108 Mounting the gantry ............................................................................................. 111 Mounting the transducer....................................................................................... 114 Mounting the hull unit on top of the installation trunk ........................................ 116 Lubricating the transducer shaft sleeve ................................................................ 117 Inspecting the transducer...................................................................................... 119 Verifying the quality of the hull unit installation .................................................122 Hull unit and transducer alignment................................................................................124 CABLE LAYOUT AND INTERCONNECTIONS........................... 125 Read this first .................................................................................................................126 Cable plans.....................................................................................................................127 Topside cable plan ................................................................................................128 List of topside cables ............................................................................................129 Sonar room cable plan ..........................................................................................130 List of sonar room cables .....................................................................................131 Comments.............................................................................................................132 Options .................................................................................................................134 Installing the SY50 cables .............................................................................................135 Prerequisites for cable installation .......................................................................136 Installing the topside cables .................................................................................136 Installing the sonar room cables ...........................................................................138 Processor Unit front panel description: Nexcom NISE 3900E............................139 Processor Unit rear panel description: Nexcom NISE 3900E .............................140 Operating Panel connectors (Mk2).......................................................................143 Operating Panel connectors (Mk3).......................................................................143 467020/B 5 Simrad SY50 Cable drawings and specifications .................................................................................144 C22 AC Power cable ............................................................................................145 C24 Control cable.................................................................................................146 C25 Transducer cable ...........................................................................................147 AC power cable using IEC C13 inline socket ......................................................148 Ground cable ........................................................................................................150 RS-232 serial line connection using three wires ..................................................151 RS-232 serial line connection using five wires ....................................................152 RS-232 used as synchronization trigger (input or output) ...................................153 RJ45 High speed Ethernet cable (1000Base-t).....................................................154 K-Sync interface to generic RS-232 synchronization input .................................155 Simrad TU40 interface to generic RS-232 synchronization input .......................157 About serial lines..................................................................................................159 SETTING TO WORK .............................................................. 162 Setting to work summary ...............................................................................................163 Inspecting the installation of the SY50 system..............................................................165 Visual inspection of the display............................................................................165 Visual inspection of the Processor Unit ...............................................................167 Visual inspection of the Operating Panel .............................................................168 Visual inspection of the Power Supply Unit ........................................................170 Visual inspection of the hull unit..........................................................................171 Checking the environmental conditions in the sonar room ..................................173 Making sure that all SY50 system cables are properly connected .......................174 Turning on the SY50 system for the first time...............................................................176 Making sure that the operating power is correct ..................................................176 Installing the operating software ..........................................................................177 Obtaining and installing a software license for additional functionality..............178 Setting up the Operating Panel (Mk2)..................................................................179 Using more than one Operating Panel to control the sonar (Mk2) ......................182 Using a single Operating Panel to control more than one sonar (Mk2) ...............186 Turning on the entire SY50 system for the first time ...........................................190 Turning on the SY50 system for normal use........................................................193 Placing each sensor in the vessel coordinate system .....................................................195 Dimensional surveying.........................................................................................195 Surveying the transducer and the navigation sensors...........................................196 Example procedure...............................................................................................197 Vessel coordinate system......................................................................................200 Inserting the installation parameters ..............................................................................203 Inserting the ship origin and dimensions..............................................................203 Inserting the installation parameters for the transducer .......................................205 6 467020/B Installation Manual Inserting the installation parameters for the motion reference unit (MRU) .............................................................................................................208 Adjusting the built-in motion sensor offset ..........................................................210 Adjusting the stabilization offsets for the motion sensor .....................................213 Setting up the interfaces to peripheral devices ..............................................................217 Installing navigation sensors and other sensors ...................................................217 Defining the serial and Ethernet (LAN) port parameters .....................................219 Setting up the input from a navigation system (GPS) ..........................................220 Setting up the interface for speed log input..........................................................223 Setting up the interface for course gyro input ......................................................225 Configuring the sensor interface...........................................................................227 Setting up the input from a motion reference unit (MRU)...................................229 Setting up the SY50 system for synchronized operation .....................................231 Setting up input from buoys, fish aggregating devices and other external objects ..............................................................................................................234 Configuring the SY50 system for normal operation ......................................................237 Selecting measurement units ................................................................................237 Setting up the alarm limits for system protection.................................................238 Configuring the SY50 system for data recording .................................................240 Configuring the environmental parameters ..........................................................241 Selecting the language displayed in the menus and dialog boxes ........................242 Saving the current user settings............................................................................242 Defining the user-selected features on the Operating Panel ..........................................244 Selecting which Operating Panel to use ...............................................................244 Assigning user settings or presentation modes to the Operating Panel................245 Assigning functions to the rotary switches on the Operating Panel.....................247 Assigning functions to F1, F2 and F3 on the Operating Panel (Mk2) .................248 Testing the operating functionality of the SY50 system................................................251 Checking the hull unit lowering and hoisting functionality .................................251 Measuring the noise in passive mode...................................................................254 Verifying system operation by means of the Diagnostics functionality ...............256 Verifying system operation by means of the Element BITE functionality ...........260 Making a noise/speed curve to determine vessel noise ........................................264 Creating a backup with the SY50 configuration and software installation....................268 About SY50 software backup and restore ............................................................268 Creating a computer image on a USB flash drive using the Acronis True Image program.................................................................................................268 Restoring a computer image from a USB flash drive using the Acronis True Image program.................................................................................................270 Creating a bootable USB flash drive using the Acronis True Image program............................................................................................................271 467020/B 7 Simrad SY50 Installation remarks........................................................................................................273 TECHNICAL SPECIFICATIONS.............................................. 274 Introduction to technical specifications .........................................................................275 Performance specifications ............................................................................................275 Power requirements .......................................................................................................279 Display power requirements.................................................................................279 Nexcom NISE 3900E Processor Unit power requirements..................................279 Operating Panel power requirements (Mk2) ........................................................280 Operating Panel power requirements (Mk3) ........................................................280 Power Supply Unit power requirements ..............................................................280 Hull Unit power requirements ..............................................................................281 Weights and outline dimensions ....................................................................................282 Display weight and outline dimensions................................................................282 Nexcom NISE 3900E Processor Unit weight and outline dimensions ................282 Operating Panel weight and outline dimensions (Mk2) .......................................283 Operating Panel weight and outline dimensions (Mk3) .......................................283 Power Supply Unit weight and outline dimensions .............................................284 Hull Unit weight and outline dimensions.............................................................284 Environmental requirements..........................................................................................285 Display environmental requirements....................................................................285 Nexcom NISE 3900E Processor Unit environmental requirements ....................285 Operating Panel environmental requirements (Mk2) ...........................................286 Operating Panel environmental requirements (Mk3) ...........................................286 Power Supply Unit environmental requirements .................................................286 Hull Unit environmental requirements.................................................................287 Compass safe distance ...................................................................................................288 Display compass safe distance .............................................................................288 Nexcom NISE 3900E Processor Unit compass safe distance ..............................288 Operating Panel compass safe distance (Mk2).....................................................289 Operating Panel compass safe distance (Mk3).....................................................289 Power Supply Unit compass safe distance ...........................................................289 Hull Unit compass safe distance ..........................................................................290 Minimum display requirements .....................................................................................290 DRAWING FILE.................................................................... 292 About the drawings in the drawing file..........................................................................293 Nexcom NISE 3900E Outline dimensions ....................................................................294 462682 Power Supply Unit dimensions.........................................................................296 462683 Hull Unit dimensions SY50 ..............................................................................299 489609 Hull Unit dimensions SY50C ...........................................................................302 440475 Installation trunk dimensions............................................................................305 8 467020/B Installation Manual Optional units.................................................................................................................308 476352 Operating Panel dimensions (Mk3).........................................................309 440689 Operating Panel cut-out drawing( Mk2) .................................................312 443179 Operating Panel dimensions (Mk2).........................................................313 439594 Operating Panel adapter plate (Mk2) ......................................................316 467020/B 9 Simrad SY50 10 467020/B About this manual About this manual The purpose of this manual is to present the descriptions and drawings required to install the Simrad SY50 Fish-finding sonar. Target audience The manual is intended for technical personnel; such as skilled shipyard workers, electricians, qualified engineers and naval architects. It is assumed that you understand the general principles of maritime electronic equipment. You must also be familiar with computer hardware, interface technology and installation of electronic and mechanical products. Installation instructions The instructions provided in this manual must be followed carefully to ensure optimal performance. The installation procedures are presented in the order they must be done. The equipment described in this manual includes the complete system with relevant cabinets, units and items. Cabinets, units and items provided locally by the customer, installation shipyard or a local representative are not described. Information about third party products and/or services may not be included in this manual, even though these may be provided as a part of the delivery. Refer to the relevant end-user documentation provided by the manufacturer. Note Kongsberg Maritime AS will accept no responsibility for any damage or injury to the product, vessel or personnel caused by equipment that has been incorrectly installed or maintained, or by drawings, instructions or procedures that have not been prepared by us. Installation drawings The installation shipyard must provide all necessary design and installation drawings, as well as the relevant work standards and mounting procedures. The installation shipyard must design and manufacture relevant installation hardware to fit each individual hardware unit. 467020/B 11 Simrad SY50 Installation Manual Note If required, all documents provided by the shipyard for the physical installation of the SY50 system must be approved by the vessel’s national registry and corresponding maritime authority and/or classification society. Such approval must be obtained before the installation can begin. The shipowner and shipyard doing the installation are responsible for obtaining and paying for such approval. The outline dimensions of the system units are located in the Drawing file chapter in this manual. The source drawings (normally in AutoCad format) can be downloaded from our website. • https://www.kongsberg.com/sy50 Software version This publication was created for the following software version: 21.13.X. Online information All end-user manuals provided for operation and installation of your SY50 system can be downloaded from our website. This includes publications that are translated to other languages. Selected publications are also provided on IETM (Interactive Electronic Technical Manual) formats. Our website also provides information about other products from Kongsberg Maritime. • https://www.kongsberg.com/sy50 Registered trademarks Observe the registered trademarks that apply. Simrad®, SIMRAD® and the Simrad® logo are either registered trademarks, or trademarks of Kongsberg Maritime AS in Norway and other countries. Windows® is a registered trademark of Microsoft Corporation in the United States and other countries. We want your feedback We always want to improve our products. We also want our end-user documentation to be comprehensive and relevant. You can help. Please provide comments, suggestions or constructive criticism to any of our support offices. 12 467020/B Simrad SY50 Simrad SY50 Topics Important, page 14 System description, page 16 System diagram, page 18 System units, page 19 Additional required and optional items, page 25 Scope of supply, page 29 General safety rules, page 30 Installation requirements, page 32 Network security, page 35 Support information, page 36 467020/B 13 Simrad SY50 Installation Manual Important The SY50 is an advanced product. It is used with other advanced products. There is important information that you need to know. Watertight integrity The size, location and design of the sonar room must fulfil all the requirements to the vessel’s watertight integrity. In the event of a major leak, it must be possible to close all watertight hatches and/or doors to the room to maintain vessel stability and safety. The physical size of the sonar room must be limited, so that in the event of a major leak, the flooding of the room will not induce instability, or cause the vessel to capsize or sink. For more information, see Sonar room requirements. Before you turn on the SY50 system Before you turn on the SY50 system, make sure that you have sufficient water depth to lower the transducer! Caution You must never turn on the SY50 system when the ship is in dry dock. The transducer may be damaged if it transmits in open air. When the SY50 system is not used When you do not use the SY50 system, turn it off. Note You must never turn off the SY50 system by means of the on/off switch on the Processor Unit. You must ALWAYS use the Operating Panel. When you are docking your vessel You must never set the SY50 system to normal operation when the ship is in dry dock. The transducer may be damaged if it transmits in open air. To prevent inadvertent use of the SY50 system, pull out the mains plug on the Processor Unit whenever your vessel is in dry dock. Additional precautionary measurers should be considered. If something breaks down If you believe that something has broken down, contact your local dealer. A list of all our dealers is provided on our website. • https://www.kongsberg.com/sy50 If you are unable to contact a dealer, observe the support information in this publication. 14 467020/B Simrad SY50 When you want to turn off the SY50 system You must never turn off the SY50 system by means of the on/off switch on the Processor Unit. When you do not use the SY50 system, turn it off with the Power button on the Operating Panel. If the transducer is lowered when you turn off the SY50 system, it is automatically retracted to its upper position. Note If you turn off the SY50 system by means of the on/off switch on the Processor Unit you can damage the software and the interface settings used to communicate with external devices. Manual operation of the hull unit In the event of improper operation, the powerful electric motor on the hull unit may cause serious damage to the equipment and/or injury to personnel. Therefore, before you start manual operation, read carefully through the relevant operating procedures. Note You must familiarize yourself with the correct handling methods and the relevant safety requirements. Rules for transducer handling A transducer must always be handled as a delicate instrument. Incorrect actions may damage the transducer beyond repair. A physical blow to the transducer face may easily damage one or more elements. Observe these transducer handling rules: • Do not activate the transducer when it is out of the water. • Do not handle the transducer roughly. Avoid impacts. • Do not expose the transducer to direct sunlight or excessive heat. • Do not use high-pressure water, sandblasting, metal tools or strong solvents to clean the transducer. • Do not damage the outer protective skin of the transducer. • Do not damage the outer protective skin of the transducer face. • Do not step on the transducer cable. • Do not damage the transducer cable. Avoid exposure to sharp objects. Related topics Simrad SY50, page 13 467020/B 15 Simrad SY50 Installation Manual System description The SY50 is an omnidirectional medium frequency fish-finding sonar designed for coastal fisheries. The SY50 sonar system is mainly designed for smaller fishing vessels. It still offers the latest technology available, functionality you have formerly found only in the larger sonars and other acoustic systems we have designed. • All transceiver electronics are placed inside the transducer. This means less cables, less noise and easier installation. • The diameter of the installation trunk is eight inches. This makes it easy to retrofit an older sonar system with a new SY50 system. • The hull unit can be placed on new or existing installation trunks with different heights. The height of the installation trunk and the length of the transducer shaft can be adjusted to fit the size of the vessel. • The transducer can be lowered to 400 or 600 millimetres below the hull. • Maximum vessel speed with the transducer fully lowered is 10 knots. The centre operational frequency is 57 kHz. You can select any operational frequency from 54 to 60 kHz. This frequency range gives you an operating range of up to 2000 metres depending on the acoustic conditions. The transmitted sonar beams can be tilted electronically. This allows you to search the whole water column and optimise the sonar performance to match the acoustic conditions. A built-in stabilizing system is included for electronic pitch and roll compensation, but you can connect to an external sensor for improved accuracy. The compact size and ease of installation makes the SY50 system ideal for vessels with limited room for a sonar installation. There is no transceiver cabinet, only a small power supply. All transceiver electronics are placed inside the transducer. The communication between the hull unit and the Processor Unit on the bridge is limited to a single Ethernet cable. Both the hull unit and the Processor Unit can operate from DC power. This makes the SY50 system a perfect choice for coastal fishing vessels that do not have 3-phase power on-board. The SY50 system transmits and receives using centre frequency 57 kHz. This allows a typical range up to 2000 metres. By means of 256 individual channels the SY50 system offers a clear and high-resolution sonar presentation not previously seen on a sonar in this price range. Our well known "large sonar“ functions like full beam stabilisation, vertical views, FM transmission, single-ping transmission (horizontal and vertical in one ping) are included. The popular operating software known from all our latest products is used. With the user interface available in almost 20 languages the SY50 system is exceptionally easy to use. The system is provided with a small and compact computer. It does not contain any fans or other moving parts, and can safely be installed in a humid environment. To simplify the basic operating features we can also provide a small operating panel. 16 467020/B Simrad SY50 The SY50 system offers the same user interface and operating software as our other sonars, echo sounders and catch monitoring systems. This enables easier and faster training of new users. • The echo presentations are optimised for multiple displays. Provided that you have connected additional displays to your Processor Unit, you can use the Docking Views function to take any sonar view and place it on a separate display. When you move a view to another display, it will automatically be scaled for the best possible result. • It is common for sonars to require many pings to build the various views in the echo presentation. On the SY50, all the sonar views in the presentation are built using the echoes from one single ping. This dramatically improves the update rate and provides better real-time information. • The SY50 system permits you to record real-time sonar situations. This allows you to replay complete sequences. The playback contains the exact same echo information, and can be used for mission history, training or troubleshooting purposes. Great emphasis has been placed on an intuitive user interface and the best possible sonar presentations on a high resolution colour display. The SY50 system is equipped with the celebrated signal processing software developed by Kongsberg Maritime. This includes Hyperbolic FM (HFM) transmissions. This pulse type is also known as "chirp". It ensures a clutter free picture with very high resolution in range. The signal processing and beamforming is performed in a fast digital signal processing system using the full dynamic range of the signals. The SY50 system software operates using the Microsoft® Windows® operating system. Related topics Simrad SY50, page 13 467020/B 17 Simrad SY50 Installation Manual System diagram The system diagram identifies the main components of a basic SY50 system. Only the main connections between the units are shown. Detailed interface capabilities and power cables are not shown. A Display E Hull Unit B Processor Unit F Hoisting motor C Operating Panel G Installation trunk D Power Supply Unit H Transducer In this publication, the computer can also be referred to as the Processor Unit, and vice versa. Unless otherwise specified in a contract, the display is not included in the standard delivery from Kongsberg Maritime. This is a commercial item that can be purchased locally. A choice of hull units is available for the SY50 system. The hull units offer different physical properties and lowering depths. The same transducer is used on all hull unit types. Related topics Simrad SY50, page 13 18 467020/B Simrad SY50 System units Topics Display, page 19 Processor Unit, page 20 Power Supply Unit, page 20 Hull Unit, page 21 Transducer, page 22 Installation trunk, page 23 Display A display is a required part of the SY50 system. For best readability, the display must be protected from glare and have the correct height and angle. Any commercial display can be used with the SY50 system, provided that the display meets the minimum requirements. Tip You may find it useful to have more than one display connected to the SY50 system. You can use more than one display on your SY50 system. The number of displays must be chosen to fit the preferences of the crew. The display is not a standard part of the delivery. This is a commercial item that can be purchased locally. Kongsberg Maritime may provide a suitable display. The chosen display must be designed for maritime use, and it must meet the minimum performance specifications. The video interface must match the output format(s) provided by the Processor Unit. Related topics Simrad SY50, page 13 System units, page 19 Installing the SY50 system hardware units, page 64 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 467020/B 19 Simrad SY50 Installation Manual Processor Unit A dedicated maritime computer is provided. In this publication, the computer can also be referred to as the Processor Unit, and vice versa. The Processor Unit is a rugged and powerful computer. It is designed for long life in a demanding maritime environment. The Processor Unit contains the operational software, and offers the user interface that allows you to control the SY50 system. Furthermore, it offers a number of serial and Ethernet lines for communication with external devices. The Processor Unit is normally mounted on the bridge. Related topics Simrad SY50, page 13 System units, page 19 Installing the SY50 system hardware units, page 64 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 Power Supply Unit A dedicated power supply unit is provided with the SY50 system. The purpose of the Power Supply Unit is to provide the hull unit with the necessary power for operation. The Power Supply Unit also controls the Ethernet communication between the transducer and the Processor Unit. The Power Supply Unit further contains the logic circuitry required to control the lower and hoist operation, as well as a small motion sensor. The Power Supply Unit is mounted on the bulkhead close to the hull unit. WARNING The Power Supply Unit contains high voltages. Unless required for maintenance purposes, do not open the cabinet door while the SY50 system is switched on. Observe the physical size and weight of the Power Supply Unit. Unless a suitable lifting device available, make sure that enough manpower is available to lift, hold and fasten the Power Supply Unit. Avoid installation heights exceeding two metres. Related topics Simrad SY50, page 13 System units, page 19 Installing the SY50 system hardware units, page 64 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 20 467020/B Simrad SY50 Hull Unit The hull unit is used to lower the transducer down below the ship’s hull when the SY50 system shall be used. When the SY50 system is turned off, the transducer is hoisted for protection. The hull unit is a mechanical construction. It is mounted on the top of the installation trunk. The installation trunk penetrates the ship’s hull, and allows the transducer to be lowered into the sea. The hull unit is normally located in the forward part of the vessel. This location is recommended to avoid the noise from the propellers and the engine. Caution When the transducer is lowered, the depth of water under the vessel must be monitored closely. If the transducer hits larger objects or bottom, the transducer shaft may be bent, or - in worst case - it can be broken off. A broken transducer shaft will cause water leakage through the top of the shaft. If you suspect that the transducer shaft is seriously damaged with holes, do not retract the transducer to its upper position. To prevent serious damage to the vessel or the vessel stability, you must have a water pump and a warning system in the sonar room. If you forget to hoist the transducer before the SY50 system is turned off, the transducer is hoisted automatically before the power is disconnected. The transducer is also hoisted automatically if a serious malfunction occurs to the communication between the bridge and the hull unit. In the event of improper operation, the powerful electric motor on the hull unit may cause serious damage to the equipment and/or injury to personnel. Therefore, before you start manual operation, read carefully through the relevant operating procedures. You must familiarize yourself with the correct handling methods and the relevant safety requirements. The SY50 system can be provided with one of the following hull units: Hull Unit Lowering depth (mm) Maximum speed (knots) SY50 400/600 10 SY50C 400 12 The same transducer is used on all hull unit types. Related topics Simrad SY50, page 13 System units, page 19 Installing the hull unit, page 88 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 467020/B 21 Simrad SY50 Installation Manual Transducer The cylindrical transducer allows the sonar beam to provide a full 360 degrees coverage of the water volume. The horizontal beam can be tilted from –10 to +60 degrees. The transducer converts the electric energy generated by the transmitter circuitry to physical vibrations. These vibrations alter the water pressure, and create an acoustic pulse that is sent into the water. The acoustic signal is transmitted as a beam. The duration of the acoustic pulse, as well as its frequency and shape, are controlled by the system software. The direction and opening angle of the beam is controlled by the transmitter circuitry and the physical properties of the transducer. After the transmission, the transducer works as a "microphone". It converts the water pressure created by the acoustic echoes to electric energy. These weak echo signals are sent to the amplifiers in the receiver circuitry. Note The transducer is covered with a thick red or black protective coating made of a special plastic type. The protective coating is a vital part of the transducer. It is very important that neither this coating nor the internal parts of the transducer are damaged during the handling, installation or cleaning. Any holes and/or scratches in the transducer surface will allow water to penetrate the transducer. If a leak occurs, the transducer must be replaced. The transducer is mounted at the bottom end of the hull unit’s transducer shaft. This allows the transducer to be lowered into the water for operational use, and retracted for protection when the SY50 system is turned off. By lowering the transducer into the water, you may also be able to reduce the noise created by the laminar flow of water along the hull. Rules for transducer handling A transducer must always be handled as a delicate instrument. Incorrect actions may damage the transducer beyond repair. A physical blow to the transducer face may easily damage one or more elements. Observe these transducer handling rules: • Do not activate the transducer when it is out of the water. • Do not handle the transducer roughly. Avoid impacts. • Do not expose the transducer to direct sunlight or excessive heat. • Do not use high-pressure water, sandblasting, metal tools or strong solvents to clean the transducer. • Do not damage the outer protective skin of the transducer. • Do not damage the outer protective skin of the transducer face. • Do not step on the transducer cable. • Do not damage the transducer cable. Avoid exposure to sharp objects. 22 467020/B Simrad SY50 Related topics Simrad SY50, page 13 System units, page 19 Installing the hull unit, page 88 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 Installation trunk An installation trunk is required for hull unit installation. The installation trunk is not included in the standard delivery. The installation trunk provides the physical foundation for the entire hull unit. The installation trunk penetrates the hull. The installation trunk is therefore a crucial part of the hull unit assembly. In order to ensure proper operation of the SY50 system, the physical location of the installation trunk must be carefully selected. The installation trunk - with a blind flange - can be ordered from Kongsberg Maritime as an optional delivery. As an alternative, the installation trunk can be manufactured by the shipyard based on the drawings in this manual. A locally manufactured installation trunk can be adjusted to better fit the properties of the vessel’s hull. Note If the installation trunk is manufactured locally, the installation shipyard is responsible for obtaining the approval certificates from the relevant national registry. Tip You can use a standard pipe to manufacture your own installation trunk. Use the following type: • 219.1x12.7, 8" Schedule 80 You can also use an existing installation trunk provided that it complies to the following internal diameter: • Steel: ø190 ±0.5 mm • Aluminium: ø191 +3/-0 mm 467020/B 23 Simrad SY50 Installation Manual Related topics Additional required and optional items, page 25 Simrad SY50, page 13 System units, page 19 Mounting the installation trunk, page 75 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 24 467020/B Simrad SY50 Additional required and optional items Topics Installation trunk, page 25 Speed log, page 26 Course gyro, page 26 Uninterruptible power supply (UPS), page 27 Operating Panel, page 27 Global positioning system (GPS), page 28 Installation trunk An installation trunk is required for hull unit installation. The installation trunk is not included in the standard delivery. The installation trunk provides the physical foundation for the entire hull unit. The installation trunk penetrates the hull. The installation trunk is therefore a crucial part of the hull unit assembly. In order to ensure proper operation of the SY50 system, the physical location of the installation trunk must be carefully selected. The installation trunk - with a blind flange - can be ordered from Kongsberg Maritime as an optional delivery. As an alternative, the installation trunk can be manufactured by the shipyard based on the drawings in this manual. A locally manufactured installation trunk can be adjusted to better fit the properties of the vessel’s hull. Note If the installation trunk is manufactured locally, the installation shipyard is responsible for obtaining the approval certificates from the relevant national registry. Tip You can use a standard pipe to manufacture your own installation trunk. Use the following type: • 219.1x12.7, 8" Schedule 80 You can also use an existing installation trunk provided that it complies to the following internal diameter: • Steel: ø190 ±0.5 mm • Aluminium: ø191 +3/-0 mm 467020/B 25 Simrad SY50 Installation Manual Related topics Additional required and optional items, page 25 Simrad SY50, page 13 System units, page 19 Mounting the installation trunk, page 75 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 Speed log In order to operate correctly, the SY50 system requires input from a speed log. Unless specified in the contract, a speed log is not a part of the SY50 system delivery. Provided that a speed log sensor is interfaced to the SY50 system, the vessel’s current speed can be presented in the user interface. Note Without speed information, the SY50 system will neither be able to present correct navigational information, nor compensate for vessel movements. This lack of compensation will prevent the system from providing correct echo information. In most cases a suitable sensor is already installed on the vessel. A global positioning system (GPS) with a compatible output format can also be used. Related topics Additional required and optional items, page 25 Course gyro In order to operate correctly, the SY50 system requires input from a course gyro. A course gyro is not a part of the SY50 delivery. When a course gyro is connected to the SY50, the vessel’s current heading can be presented in the user interface. Without the input from a course gyro, the SY50 system will not be able to present correct navigational information. In most cases a suitable course gyro is already installed on the vessel. Note Most global positioning system (GPS) can provide course information, but this data is generally too inconsistent to provide a stable presentation on the SY50 system. This inconsistency is especially noticeable at low vessel speeds. Incorrect course information can then result in settings not working properly. We recommend that you use a satellite compass or a gyro compass. 26 467020/B Simrad SY50 Related topics Additional required and optional items, page 25 Uninterruptible power supply (UPS) It is important to ensure continuous operation of the SY50 system independent of any varying quality of the vessel's mains supply. The use of uninterruptible power supplies (UPS) is therefore required. Uninterruptible power supply units are not included in the standard SY50 system delivery. These items must be purchased locally. Several commercial types are available. Note Make sure that the Uninterruptible Power Supply (UPS) does not generate switching noise in the same frequency band as the SY50 system. To choose the best power solution for your installation, consider environmental conditions, the physical space available, the availability and duration of the batteries, and the power requirements of the SY50 system. Related topics Additional required and optional items, page 25 Operating Panel The optional Operating Panel contains all necessary control functions for normal operation of the SY50 system. The Operating Panel offers all necessary control functions for normal operation. The controls provided by the Operating Panel are arranged in logical functional groups. This offers you clear and easy operation with fast access to key functionality. All the functionality provided by the SY50 system can be accessed using the trackball on the Operating Panel and the menu system shown in the display presentation. The SY50 system supports two different operating panels. These are referred to as "Mk2" and "Mk3". • The Mk2 Operating Panel is connected to the Processor Unit using an Ethernet cable. • The Mk3 Operating Panel is connected to the Processor Unit with a USB cable. The Mk3 Operating Panel is the standard panel provided for the SY50 system. Related topics Additional required and optional items, page 25 467020/B 27 Simrad SY50 Installation Manual Global positioning system (GPS) A global positioning system (GPS) may be connected to the SY50 system. When a global positioning system (GPS) connected to the SY50 system, the vessel’s current geographical position can be presented in the user interface. It will also provide latitude and longitude information for the cursor and marker(s). In addition to navigational data, the global positioning system (GPS) can also be used to provide speed information. Note Most global positioning system (GPS) can provide course information, but this data is generally too inconsistent to provide a stable presentation on the SY50 system. This inconsistency is especially noticeable at low vessel speeds. Incorrect course information can then result in settings not working properly. Related topics Additional required and optional items, page 25 28 467020/B Simrad SY50 Scope of supply To assemble a complete SY50 system you need all the system units. The main units you need are provided with the standard delivery. Additional items are required for operation. These items must be added to the SY50 system for full operational functionality. Some items are optional. Such items can be purchased from Kongsberg Maritime or obtained locally. Basic items When you unpack the parts provided with the SY50 system delivery, make sure that the correct items are included. The quantity of each item is specified in the contract and/or the order confirmation. Relevant order information is provided on our website. • https://www.kongsberg.com/sy50 Operational software Operational software is provided on a suitable media. End-user documentation End-user documentation is provided on paper and/or digital formats. End user manuals and source drawings (normally in AutoCad format) can be downloaded from our website. • https://www.kongsberg.com/sy50 Related topics Simrad SY50, page 13 467020/B 29 Simrad SY50 Installation Manual General safety rules Safety is important. The safety precautions must be followed at all times during installation and maintenance work. WARNING The SY50 system operates on 24 VDC and/or 230 VAC (50/60 Hz). These voltages are potentially lethal! You must never work alone on high-voltage equipment! This equipment must be installed, adjusted, and serviced only by qualified electrical maintenance personnel familiar with the construction and operation of the equipment and the hazards involved. Failure to observe this precaution could result in bodily injury. Personnel requirements All personnel must be trained in relevant installation and maintenance work. Personal protection Installation personnel must wear suitable work clothes. The work clothes must not contain sufficient static to ignite. Always wear a hard hat and suitable protective footwear while handling heavy objects. Power and ground You must always turn off all power before installation or maintenance work on the SY50 system. Use the main circuit breaker, and label the breaker with a warning sign that informs others that maintenance or installation work is in progress on the system. For safety reasons, two persons must always be present during troubleshooting with power turned ON. All SY50 system units must be properly grounded. First aid Read and understand the applicable first aid instructions related to electric shock. Whenever installation or maintenance work is in progress, it is essential that a first aid kit is available. All personnel must be familiar with the first aid instructions for electrical shock and other personal injuries. Weight The various parts of the system may be heavy. Make sure that the appropriate tools and certified lifting equipment are available. Always wear a hard hat and suitable protective footwear while handling heavy objects. Cables Each electric cable must be handled carefully. This is important to avoid damage to the cable. This is also important to avoid electric shock in the event that the cable is unintentionally connected to a power source. 30 467020/B Simrad SY50 Cabinets Do not open racks or cabinet doors while sailing in rough seas. Doors and/or cabinet parts may suddenly swing open and cause damage or injury. Related topics Simrad SY50, page 13 Preparations, page 39 Installing the SY50 system hardware units, page 64 Installing the hull unit, page 88 467020/B 31 Simrad SY50 Installation Manual Installation requirements Topics Supply voltage requirements, page 32 Uninterruptible power supply (UPS) requirements, page 32 Cables and wiring requirements, page 33 Compass deviation requirements, page 33 Noise sources, page 34 Dry docking requirements, page 34 Requirement for classification approval, page 35 Supply voltage requirements The supply voltage must kept within ±10% of the installation’s nominal voltage. Maximum transient voltage variations on the main switchboard’s bus-bars must not exceed -15% to +20% of the nominal voltage (except under fault conditions). Related topics Simrad SY50, page 13 Installation requirements, page 32 Uninterruptible power supply (UPS) requirements It is important to ensure continuous operation of the SY50 system independent of any varying quality of the vessel's mains supply. The use of uninterruptible power supplies (UPS) is therefore required. Uninterruptible power supply units are not included in the standard SY50 system delivery. These items must be purchased locally. Several commercial types are available. Note Make sure that the Uninterruptible Power Supply (UPS) does not generate switching noise in the same frequency band as the SY50 system. To choose the best power solution for your installation, consider environmental conditions, the physical space available, the availability and duration of the batteries, and the power requirements of the SY50 system. Two UPS systems are required. 32 467020/B Simrad SY50 1 One UPS system is required to supply the Processor Unit and the display. 2 One UPS system is required to supply the Power Supply Unit and the hull unit. A single UPS system is sufficient if the power capacity is provided and long cable runs are avoided. The minimum requirements for the uninterruptible power supply (UPS) are: • Input voltage: The input voltage must fit vessel supply voltage. • Output voltage: 230 VAC, 50 Hz • Output power: – Processor Unit/Display: 1000 W – Power Supply Unit/Hull Unit: 1000 W • Output form: The output AC voltage must be a sine wave. Related topics Simrad SY50, page 13 Installation requirements, page 32 Cables and wiring requirements Correct wiring is crucial for the operational performance of the SY50 system. All cables running between system cabinets located in different rooms and/or on different decks must be supported and protected along their entire lengths using conduits and/or cable trays. Note that the cables must not be installed in the vicinity of high-power supplies and cables, antenna cables or other possible sources of interference. Related topics Simrad SY50, page 13 Installation requirements, page 32 Cable layout and interconnections, page 125 Compass deviation requirements SY50 units that are installed on the bridge may have an effect on the compass. Once the installation is complete, the vessel must be swung with the SY50 system in both operative and inoperative modes. The shipowner and captain are responsible for updating the compass deviation table accordingly with regard to the vessel’s national registry and corresponding maritime authority. Related topics Simrad SY50, page 13 Installation requirements, page 32 467020/B 33 Simrad SY50 Installation Manual Noise sources The operational performance of the SY50 system depends on the noise conditions. It is essential that the noise signature is as low as possible. Vessel noise The vessel’s hull, rudder(s) and propeller(s) must be thoroughly inspected in dry dock prior to installation. Roughness below the water-line deformities in the shell plating and protruding obstacles can create underwater noise. These sources of turbulence must be smoothed or removed as best as possible. Note It is especially important that the propeller(s) are not pitted or damaged. Electrical noise The quality of the vessel’s supply power is crucial to reduce noise. Electrical or electronic self noise is picked up or generated in any other part of the equipment than the transducer. The most common source of electrical self noise is hum. The hum is normally generated by a low quality power supply.It is then picked up by cables and/or sensitive electronic circuitry. At higher frequencies – where rather wide bandwidths are necessary – the noise from components, transistors or other analogue electronic may be a limiting factor. Related topics Simrad SY50, page 13 Installation requirements, page 32 Dry docking requirements Whenever a hull unit and an installation trunk are mounted under the vessel’s hull, special considerations must be made prior to dry docking. The location of the SY50 installation trunk must be noted on the vessel’s docking plan for future reference. Make sure that ample clearance under the SY50 installation trunk and/or blister is provided when you are placing the vessel in dry dock. Avoid locating supporting blocks or structures in the vicinity of the SY50 installation trunk. Important Prior to dry docking, turn off the SY50 system. If necessary, disengage the circuit breaker. Label the Processor Unit and/or the circuit breaker clearly to prevent anyone from accidentally turning on the SY50 system. 34 467020/B Simrad SY50 Related topics Simrad SY50, page 13 Installation requirements, page 32 Requirement for classification approval Classification approval is required for the SY50 system installation. The design and mounting of the installation trunk for the SY50 system must be approved by the vessel’s national registry and corresponding maritime authority and/or classification society. The shipowner and shipyard doing the installation are responsible for obtaining and paying for such approval. Related topics Simrad SY50, page 13 Installation requirements, page 32 Network security If a SY50 system is connected to a local area network, data security is important. Equipment manufactured by Kongsberg Maritime is frequently connected to the vessel's local area network (LAN). When you connect a computer to a local area network you will always expose the data on that computer. All other computers connected to the same network may be able to access your data. Several threats may immediately occur: • Remote computers can read the data. • Remote computers can change the data. • Remote computers can change the behavior of the computer, for example by installing unwanted software. Usually, two parameters are used to define the threat level: 1 The likelihood that any remote computer will do any of the above. 2 The damage done if a remote computer succeeds doing this. Kongsberg Maritime has no information regarding the complete system installation on any vessel. Systems provided by Kongsberg Maritime are regarded as stand-alone offline systems. They are stand-alone even though they may be connected to a network for sensor interfaces and/or data distribution. Note No network safety applications are installed on Kongsberg Maritime computers. The computers are therefore not protected against viruses, malware or unintentional access by external users. 467020/B 35 Simrad SY50 Installation Manual Securing the SY50 system itself has no meaning unless there is a policy in place that secures all computers in the network. This policy must include physical access by trained and trusted users. The customer/end user of the SY50 system will always be in charge of defining and implementing a security, policy and providing the relevant network security applications. Note Kongsberg Maritime will not accept any responsibility for errors and/or damages caused by unauthorized use of or access to the SY50. Related topics Simrad SY50, page 13 Support information If you need technical support for your SY50 system you must contact your local dealer, or one of our support offices. A list of all our offices and dealers is available on our website. You can also contact our main support office in Norway. Norway (main office) • Company name: Kongsberg Maritime AS / Simrad • Address: Strandpromenaden 50, N3190 Horten, Norway • Telephone: +47 33 03 40 00 • Telefax: +47 33 04 29 87 • Website: www.kongsberg.com/simrad • Email address: [email protected] Spain • Company name: Kongsberg Maritime Spain S.L.U • Address: Partida Atalayes 20, 03570 Villajoyosa, Spain • Telephone: +34 966 810 149 • Telefax: +34 966 852 304 • Website: www.kongsberg.com/simrad • Email address: [email protected] France • Company name: Simrad France • Address: 5 rue de Men Meur, 29730 Guilvinec, France 36 467020/B Simrad SY50 • Telephone: +33 298 582 388 • Telefax: +33 298 582 388 • Website: www.kongsberg.com/simrad • Email address: [email protected] USA • Company name: Kongsberg Underwater Technology LLC (KUTL) / Simrad Fisheries • Address: 19210 33rd Ave W, Suite A, Lynnwood, WA 98036, USA • Telephone: +1 425 712 1136 • Telefax: +1 425 712 1193 • Website: www.kongsberg.com/simrad • Email address: [email protected] Canada • Company name: Kongsberg Mesotech Ltd. • Address: 1598 Kebet Way, Port Coquitlam, BC, V3C 5M5, Canada • Telephone: +1 604 464 8144 • Telefax: +1 604 941 5423 • Website: www.kongsberg.com/simrad • Email address: [email protected] Malaysia • Company name: Kongsberg Maritime Malaysia Sdn. Bhd • Address: Unit 27-5 Signature Offices, The Boulevard, Mid Valley City, Lingkaran Syed Putra, 59200 Kuala Lumpur, Malaysia • Telephone: +65 6411 7488 • Telefax: +60 3 2201 3359 • Website: www.kongsberg.com/simrad • Email address: [email protected] Korea • Company name: Kongsberg Maritime Korea Ltd • Address: #1101 Harbor Tower, 113-1, Nampodong 6-Ga, Jung-Gu, Busan 600-046, Korea • Telephone: +82 51 242 9933 • Telefax: +82 51 242 9934 467020/B 37 Simrad SY50 Installation Manual • Website: www.kongsberg.com/simrad • Email address: [email protected] China • Company name: Kongsberg Maritime China Ltd • Address: 555 Chuanqiao Road, China (Shanghai) Pilot Free Trade Zone, 201206, China • Telephone: +86 21 3127 9888 • Telefax: +86 21 3127 9555 • Website: www.kongsberg.com/simrad • Email address: [email protected] Related topics Simrad SY50, page 13 38 467020/B Preparations Preparations Topics Installation summary, page 40 General safety rules, page 42 About installation drawings, page 43 Tools, equipment and consumables required for installation, page 44 Personnel qualifications, page 44 Rules for transducer handling, page 45 Choosing the best location for the hull unit, page 47 Sonar room requirements, page 50 Acoustic noise, page 56 467020/B 39 Simrad SY50 Installation Manual Installation summary Installation of the SY50 system is a demanding task that requires careful preparations, a number of specific procedures, wiring and required system settings. Context An overall installation procedure is provided. This procedure does not describe any detailed tasks. Refer to the relevant tasks in this manual. Note In order to obtain maximum safety and optimal performance, it is very important that the installation procedures in this manual are complied to. You must do the tasks in the order they are described. The vessel owner must make sure that the installation shipyard holds the applicable competence to perform the installation, and that the applicable maritime authorities are available to verify and certify the installation. The size, location and design of the sonar room must fulfil all the requirements to the vessel’s watertight integrity. In the event of a major leak, it must be possible to close all watertight hatches and/or doors to the room to maintain vessel stability and safety. The physical size of the sonar room must be limited, so that in the event of a major leak, the flooding of the room will not induce instability, or cause the vessel to capsize or sink. If required, all documents provided by the shipyard for the physical installation of the SY50 system must be approved by the vessel’s national registry and corresponding maritime authority and/or classification society. Such approval must be obtained before the installation can begin. The shipowner and shipyard doing the installation are responsible for obtaining and paying for such approval. Procedure 1 Based on the vessel drawings and best practice, determine where the hull unit shall be located. Necessary considerations must be taken to avoid acoustic and electric disturbances. Note The information in this document must be regarded as general guidelines and recommendations only. The installation shipyard must design and manufacture installation hardware to fit the transducer to each individual vessel. Whenever required, the installation shipyard must also have the transducer installation approved by the applicable maritime authorities. Choosing the best location for the hull unit, page 47 Acoustic noise, page 56 2 Prepare the sonar room to meet the installation requirements. Sonar room requirements, page 50 40 467020/B Preparations 3 Mount the installation trunk. Note The installation trunk will penetrate the hull. For this reason, mounting the installation trunk correctly is a crucial part of the installation. Mounting the installation trunk, page 75 4 Mount the hull unit on top of the installation trunk. Installing the hull unit, page 88 5 Install the SY50 system units. Note that some SY50 system units may be commercial. Unless ordered specifically these are not included in the delivery, and must be purchased locally. Installing the SY50 system hardware units, page 64 6 Install the cables between the SY50 system units. This is described in the Cable layout and interconnections chapter. Observe the relevant cable plan, procedures, as well as the general requirements for cabling. Cable layout and interconnections, page 125 7 Install the cables between the SY50 system and the relevant peripheral devices. This is described in the Cable layout and interconnections chapter. Observe the relevant cable plan, procedures, as well as the general requirements for cabling. For more information, refer to the end-user documentation provided by the manufacturer. Cable layout and interconnections, page 125 8 Turn on the SY50 system for the first time, and set it to work. Note In order to turn on the SY50 system in a safe and correct manner, the relevant procedures must be complied to! Setting to work, page 162 Further requirements Fill in and sign the Installation Remarks form, and send it to the Simrad support department as specified on the form. Related topics Preparations, page 39 467020/B 41 Simrad SY50 Installation Manual General safety rules Safety is important. The safety precautions must be followed at all times during installation and maintenance work. WARNING The SY50 system operates on 24 VDC and/or 230 VAC (50/60 Hz). These voltages are potentially lethal! You must never work alone on high-voltage equipment! This equipment must be installed, adjusted, and serviced only by qualified electrical maintenance personnel familiar with the construction and operation of the equipment and the hazards involved. Failure to observe this precaution could result in bodily injury. Personnel requirements All personnel must be trained in relevant installation and maintenance work. Personal protection Installation personnel must wear suitable work clothes. The work clothes must not contain sufficient static to ignite. Always wear a hard hat and suitable protective footwear while handling heavy objects. Power and ground You must always turn off all power before installation or maintenance work on the SY50 system. Use the main circuit breaker, and label the breaker with a warning sign that informs others that maintenance or installation work is in progress on the system. For safety reasons, two persons must always be present during troubleshooting with power turned ON. All SY50 system units must be properly grounded. First aid Read and understand the applicable first aid instructions related to electric shock. Whenever installation or maintenance work is in progress, it is essential that a first aid kit is available. All personnel must be familiar with the first aid instructions for electrical shock and other personal injuries. Weight The various parts of the system may be heavy. Make sure that the appropriate tools and certified lifting equipment are available. Always wear a hard hat and suitable protective footwear while handling heavy objects. Cables Each electric cable must be handled carefully. This is important to avoid damage to the cable. This is also important to avoid electric shock in the event that the cable is unintentionally connected to a power source. 42 467020/B Preparations Cabinets Do not open racks or cabinet doors while sailing in rough seas. Doors and/or cabinet parts may suddenly swing open and cause damage or injury. Related topics Simrad SY50, page 13 Preparations, page 39 Installing the SY50 system hardware units, page 64 Installing the hull unit, page 88 About installation drawings The installation shipyard must provide all necessary design and installation drawings, as well as the relevant work standards and mounting procedures. Note If required, all documents provided by the shipyard for the physical installation of the SY50 system must be approved by the vessel’s national registry and corresponding maritime authority and/or classification society. Such approval must be obtained before the installation can begin. The shipowner and shipyard doing the installation are responsible for obtaining and paying for such approval. Kongsberg Maritime offers free advice for installation planning. Proposed arrangements may be sent for commentary or suggestions. The following drawings should be submitted should assistance be requested: • General arrangement • Body plan and drawings of the relevant compartment • Lines plan Relevant outline dimensions and production drawings can be download from our website. Most documents are available in PDF and/or AutoCad (DWG) formats. • https://www.kongsberg.com/sy50 Related topics Preparations, page 39 467020/B 43 Simrad SY50 Installation Manual Tools, equipment and consumables required for installation To install the SY50 system, all necessary tools and equipment for mechanical work, cabinet installation and electrical wiring must be available. It is not practical to provide a detailed list of all necessary tools and equipment. You must be equipped with a standard set of tools. This tool set must comprise the normal tools for electronic and electromechanical tasks. This includes different screwdriver types, pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in various sizes. We recommend that all tools are demagnetized to protect your equipment. However, you must make sure that the following specialized tools are available. • All necessary tools and consumables required for welding • All necessary tools and consumables required for physical installation of units, cabinets and racks • All necessary tools and consumables required for electrical installations If you need specific consumables, or if special tools and/or test instruments are required, these are identified in the relevant procedure(s). Related topics Preparations, page 39 Personnel qualifications The installation of the SY50 system is a demanding task. Installation tasks must only be done by fully trained personnel. As a minimum, the following certified personnel must be available: • Naval architects • Welders • Electricians • Project manager Note The quality of the welding is critical to the safety of the vessel. Welding must only be done by a certified welder. If applicable, the final installation welds must be approved by the vessel’s national registry, the corresponding maritime authority and/or classification society. Observe the relevant rules and regulations related to welding. Related topics Preparations, page 39 44 467020/B Preparations Rules for transducer handling To secure long life and accurate results, the transducer must be handled correctly. A transducer must always be handled as a delicate instrument. Incorrect actions may damage the transducer beyond repair. A physical blow to the transducer face may easily damage one or more elements. Observe these transducer handling rules: • Do not activate the transducer when it is out of the water. • Do not handle the transducer roughly. Avoid impacts. • Do not expose the transducer to direct sunlight or excessive heat. • Do not use high-pressure water, sandblasting, metal tools or strong solvents to clean the transducer. • Do not damage the outer protective skin of the transducer. • Do not damage the outer protective skin of the transducer face. • Do not step on the transducer cable. • Do not damage the transducer cable. Avoid exposure to sharp objects. Cleaning the transducer face Whenever opportunity arise, typically when the vessel is dry-docked, the transducer face must be cleaned for shells and other marine growth. • Be careful so that you do not accidentally make cuts or inflict other physical damage to the transducer face. • Remove biological fouling carefully using a plastic brush, a suitable synthetic detergent and fresh water. Biological material which is strongly rooted in the substrate can be removed carefully with a piece of wood or plastic. • Do not use high-pressure water, sandblasting, metal tools or strong solvents to clean the transducer. Painting the transducer face The transducer has not been designed with any protection against biological fouling. Anti-fouling paint may therefore be applied to the transducer face. To minimize the negative acoustical effects the layer of anti-fouling paint must be as thin as possible. Note The anti-fouling paint will reduce the acoustical performance of the transducer. The surface roughness of the transducer substrate and the thickness of the paint may also influence the performance. Kongsberg Maritime cannot be held responsible for any negative consequences of the anti-fouling paint. Because some paint types may be aggressive to the polyurethane in the transducer, consult our list of approved paints. The list can also be found on our website. 467020/B 45 Simrad SY50 Installation Manual Observe the relevant instructions and safety information provided by the paint manufacturer. Related topics Preparations, page 39 46 467020/B Preparations Choosing the best location for the hull unit Topics About the hull unit location, page 47 Defining the fore and aft location of the hull unit, page 48 Defining the athwartships location of the hull unit, page 48 Important considerations related to noise, page 49 About the hull unit location Selecting the best possible location for the hull unit is of vital importance for the overall sonar performance. The location of the hull unit must be selected by a skilled naval architect or engineer with experience in sonar theory and hull unit installation. Kongsberg Maritime can assist if required. The information here must be considered as general advice. Each installation must be handled separately depending on the hull design. The sonar room is the compartment in which the Hull Unit is installed. Other system units may also be installed in the sonar room. The physical location of the hull unit depends on the vessel's design and construction, how the hull is shaped, and how the water runs along the hull. Observe the following considerations: 1 The sonar room must be accessible under all conditions at sea or at a berth. 2 The size of the hatch must allow the entire hull unit to be removed without being disassembled. 3 Heating is an effective method for reducing humidity. The heater in the sonar room must be dimensioned to maintain the equipment within its environmental tolerances. Typical heating power is minimum 1000 W. The heater must be installed close to the deck. 4 If it is not possible to connect the sonar room to the vessel's bilge pump system, a separate bilge pump for the compartment must be installed. 5 The sonar room must be connected to the vessel's ventilation system to ensure a supply of cooling air. If the vessel is likely to operate in tropical conditions, an air dehumidifier is strongly recommended to reduce the likelihood of corrosion due to condensation. Related topics Choosing the best location for the hull unit, page 47 Preparations, page 39 467020/B 47 Simrad SY50 Installation Manual Defining the fore and aft location of the hull unit The hull unit should preferably be located within 1/3 to 1/10 of the vessel’s Length Between Perpendiculars (LBP) from its Forward Perpendicular (FP). Deviations should not be made without consulting Kongsberg Maritime. A Water level at normal trim B Welding marks to indicate hull unit location when docking C Length Between Perpendiculars (LBP) D 1/3 to 1/10 of the Length Between Perpendiculars (LBP) (This is a generic illustration. Any similarities with specific products are accidental. The illustration is not to scale.) Related topics Choosing the best location for the hull unit, page 47 Preparations, page 39 Defining the athwartships location of the hull unit The athwartships position is not critical. The hull unit may be located on the Centre Line (CL) of the vessel, or alongside its keel. Note If the installation is offset from the vessel’s centre line, make sure that transducer transmissions and reception will not be obstructed by the keel. 48 467020/B Preparations Related topics Choosing the best location for the hull unit, page 47 Preparations, page 39 Important considerations related to noise The operational performance of all hydroacoustic systems depend on the noise conditions. It is essential that the noise signature is as low as possible. Careful planning of the installation may reduce the acoustic noise. The installation trunk must be mounted so that it remains vertical during normal operating conditions. The fairing around the installation trunk must be streamlined. The transducer must be protruding far enough down to reach out of the boundary layer. The primary sources of underwater disturbance (other than a vessel’s main propeller and bow/stern thruster) that have a negative effect on the performance are: • Main or bilge keels • Sacrificial anodes • Cooling elements protruding from the hull • Transducers • Pilot tubes • Sea chests • Overboard discharges • Dents in the hull Important All appendages to the hull, indentations, physical damage and pipes are potential sources of underwater noise. These may act as resonant cavities amplifying noise at certain frequencies, create cavitation or turbulence. The installation trunk and hull unit must not be located in the vicinity of such objects, and especially not immediately aft of them. Related topics Choosing the best location for the hull unit, page 47 Preparations, page 39 467020/B 49 Simrad SY50 Installation Manual Sonar room requirements Topics About the sonar room, page 50 Environmental requirements, page 50 Requirements for watertight integrity, page 51 Size and access requirements, page 51 Requirements for insulation, heating and ventilation, page 52 Requirements for electrical installations, cables and communication, page 53 Requirements for bilge pump and decking, page 54 Lifting requirements, page 54 About the sonar room The sonar room is the compartment in which the Hull Unit is installed. Other system units may also be installed in the sonar room. These are typically a Transceiver Unit and/or a Power Supply Unit. It is strongly recommended to use a dedicated compartment to house these units. They must also be installed relatively close to each other due to the limited length of the cables. Related topics Sonar room requirements, page 50 Preparations, page 39 Environmental requirements The system units must be installed in a dry and dust-free environment. The units are not fully protected against humidity, dust or water. It is important that the sonar room is kept dry. The units must not be exposed to excessive temperatures, dust, moisture or humidity. Such conditions can cause corrosive attacks and subsequent failures to the electronic circuitry. Visit the sonar room at regular intervals to check temperature and humidity, and take the necessary actions if the environmental conditions are poor. Observe the environmental specifications related to each unit. 50 467020/B Preparations Related topics Sonar room requirements, page 50 Preparations, page 39 Requirements for watertight integrity The size, location and design of the sonar room must fulfil all the requirements to the vessel’s watertight integrity. In the event of a major leak, it must be possible to close all watertight hatches and/or doors to the room to maintain vessel stability and safety. The physical size of the sonar room must be limited, so that in the event of a major leak, the flooding of the room will not induce instability, or cause the vessel to capsize or sink. Inspect all watertight decks and bulkheads periodically. Make sure that there are no unprotected openings or improper penetrations that may allow progressive flooding from the compartment. Make sure that the watertight doors and hatches are in place and in good working order. Install and activate bilge high level sensors to provide an early warning of abnormal accumulation of water. Position the sensors as low as possible along the centre area of the compartment, and/or in other locations where the water will gravitate to first. Inspect the bilge sensors periodically. All cables leading in and out of the sonar room must be run in steel conduits. These steel conduits must reach up and above the freeboard deck. If required, all design documents related to the sonar room and the watertight integrity must be approved by the vessel’s national registry and corresponding maritime authority and/or classification society. Such approval must be obtained before the installation can begin. The shipowner and shipyard doing the installation are responsible for obtaining and paying for such approval. Related topics Sonar room requirements, page 50 Preparations, page 39 Size and access requirements A well designed sonar room with a well fitted size and easy access reduces the risk of corrosion, and simplifies maintenance. This increases system reliability. Note The physical size of the sonar room must be limited, so that in the event of a major leak, the flooding of the room will not induce instability, or cause the vessel to capsize or sink. 467020/B 51 Simrad SY50 Installation Manual The sonar room must be large enough to house all the system units. The room must provide enough space to allow efficient maintenance. You must be able to keep all the cabinet doors fully open without undue restriction to your movements. 1 The room must not be used for any other heavy machinery. 2 The room must not be unnecessarily obstructed by girders, pipes etc, which may cause installation problems or impede maintenance. 3 The sonar room must be accessible under all conditions at sea or at a berth. 4 All doors or hatches must be designed so that the tools and equipment can be removed without being disassembled. 5 All cables leading in and out of the sonar room must be run in steel conduits. These steel conduits must reach up and above the freeboard deck. 6 In the event of a major leak, it must be possible to close all watertight hatches and/or doors to the room to maintain vessel stability and safety. Note The physical distances between the various system units are limited by the length of the cables. Make sure that all the cables are installed in such manners that the transducer can be lowered and hoisted without damaging them. Related topics Sonar room requirements, page 50 Preparations, page 39 Requirements for insulation, heating and ventilation The bulkheads in the sonar room must be insulated and provided with an interior wall to the deck. The room must be equipped with heater, and it must be connected to the vessel's ventilation system. Insulation requirements The insulation in the sonar room should be the minimum equivalent of 50 mm of rock-wool. Piping passing through the space prone to condensation must be properly insulated. Heating requirements Heating is an effective method for reducing humidity. The heater in the sonar room must be dimensioned to maintain the equipment within its environmental tolerances. Typical heating power is minimum 1000 W. The heater must be installed close to the deck. 52 467020/B Preparations Ventilation requirements The sonar room must be connected to the vessel's ventilation system to ensure a supply of cooling air. If a ventilation system is not available, install two 3” pipes from the sonar room to a suitable fresh air location on deck. The fresh air should enter the room as close to the floor as possible, and should be extracted from as high as possible. A funnel shaped drip-collector must be mounted below the vent pipes to divert moisture to the bilge. On the main deck, the best ventilation is provided when the outlet pipe is at least four meters higher than the inlet pipe. To keep out sea water, rain and spray, the ventilation pipes must be fitted with goosenecks or an equivalent design. Note If the vessel is likely to operate in tropical conditions, a suitable air conditioning system must be installed. The air conditioning system must be able to provide an ambient temperature that does not exceed the maximum operating temperatures of the system units that are installed in the room. Related topics Sonar room requirements, page 50 Preparations, page 39 Requirements for electrical installations, cables and communication The electrical installations in the sonar room must meet minimum requirements to provide suitable lights and supply power. Light requirements The sonar room must be equipped with suitable lighting to simplify the installation and to aid future maintenance. Communication requirements The sonar room must be equipped with a telephone, an intercom system, or any other means of oral communication between the sonar room and the bridge and/or control room(s). Power requirements Each unit in the sonar room should be provided with a separate circuit breaker on the mains supply. A minimum number of additional electrical outlets must be provided for other equipment. Proper vessel ground must be provided. 467020/B 53 Simrad SY50 Installation Manual Cabling requirements The sonar room units are connected to other system units located in different compartments on the vessel. The units may also be connected to peripheral devices. If these cables pass through hatches or areas where they may be damaged, they must be run in conduits. Minimum 2” conduit is recommended. Make sure that all system cables are properly connected and secured, and installed with some slack. The slack is essential to withstand vibrations, and to facilitate future maintenance and replacements. Make sure that the transducer cable is placed in such a manner that the transducer can be lowered and hoisted without damaging the cable. Related topics Sonar room requirements, page 50 Preparations, page 39 Requirements for bilge pump and decking If the sonar room is located below the water line, it must be connected to the vessel's bilge pump system. Bilge pump requirement If it is not possible to connect the sonar room to the vessel's bilge pump system, a separate bilge pump for the compartment must be installed. Install and activate bilge high level sensors to provide an early warning of abnormal accumulation of water. Position the sensors as low as possible along the centre area of the compartment, and/or in other locations where the water will gravitate to first. Inspect the bilge sensors periodically. Decking requirement Once the installation has been completed, the sonar room must be suitably decked without restricting access to the equipment and the cables. Related topics Sonar room requirements, page 50 Preparations, page 39 Lifting requirements An attachment point for the lifting device must be located directly above the hull unit. The lifting device must be rated to minimum twice the weight of the hull unit. A permanently installed fixture will facilitate installation trunk and hull unit mounting. It can also be used for future equipment maintenance and/or replacement. 54 467020/B Preparations Related topics Sonar room requirements, page 50 Preparations, page 39 467020/B 55 Simrad SY50 Installation Manual Acoustic noise Topics Introduction to the acoustic noise challenge, page 56 Contributing factors, page 56 Self noise, page 58 Ambient noise, page 60 Electrical self noise, page 61 Reverberation, page 61 Some means to reduce acoustic noise, page 62 Introduction to the acoustic noise challenge Even with the advanced noise filtering offered by the sonar system, we must address the noise challenge. This is important during the planning and preparations for the system installation. The echoes from any large and small target must be detected inside the noise. It is important that we keep the noise level as low as possible. This is necessary to obtain long range and dependable interpretations of the echoes. Contributing factors Several factors are contributing to the performance of the hydroacoustic equipment used on board a vessel. Factors contributing to the performance of the hydroacoustic equipment used on board a vessel are: • The quality and properties of the transmitted signal • The quality of the receiving system • The operational settings made during operation • The properties of the target(s) • The signal-to-noise ratio The majority of these factors can neither be controlled nor improved by means of installation methods or transducer locations. The quality and properties of the transmitting and receiving systems are key factors during our product development, while our end user documentation aims to help you to make the right filter settings during operation. As for the target properties, there is nothing any of us can do with those. 56 467020/B Preparations The signal-to-noise ratio, however, can be improved by making the correct choices during installation. Signal-to-noise ratio (often abbreviated SNR or S/N) is a measure used in science and engineering that compares the level of a desired signal to the level of background noise. It is defined as the ratio of signal power to the noise power, often expressed in decibels. A ratio higher than 1:1 (greater than 0 dB) indicates more signal than noise. While SNR is commonly quoted for electrical signals, it can be applied to any form of signal [...]. Wikipedia, Copied September 2013 The signal is the echo that we want to know something about, while the noise is any unwanted signals or disturbances. The echo must be detected in the noise and therefore it is necessary to keep the noise level as low as possible in order to obtain high echo interpretation. The noise that contributes to the signal to noise ratio may be divided into the following types of noise: • Self noise • Ambient noise • Electrical noise • Reverberation • Underwater noise • Fishing gear noise (This is a generic illustration. Any similarities with specific products are accidental.) A The transducer can pick up noise from: • Biological disturbances • Interference • Cavitation • Propeller noise • Flow noise • Acoustic noise from other hydroacoustic systems 467020/B 57 Simrad SY50 Installation Manual B The transducer cable is long. Electric noise from generators, pumps, cooling systems and other electric or electromechanical devices is easily picked up. C The preamplifiers are very sensitive. They can easily pick up electrical noise from internal and external power supplies. The preamplifiers are also vulnerable to analogue noise created by their own electronic circuitry. Digital noise created by the converter and processing circuitry can also create noise problems. D The converters transform the analogue echoes to digital format. E Signal processing circuitry can create digital noise. Self noise Any vessel equipped with a hydroacoustic system (for example echo sounder or sonar) will produce more or less self noise. There are many sources of such self noise. It is necessary to analyse the different sources of self-noise on a vessel, and find out how each source can affect the noise level of the hydroacoustic instruments. Machinery noise The main contributor to machinery noise is usually the main engine on board the vessel. The contribution from auxiliary machinery may, however, be considerable, especially if it is in poor shape. The machinery noise can be transmitted to the transducer as: • Structure-borne noise through the ship structure and the transducer mountings. • Water-borne noise through the hull into the water to the transducer. Electrical noise Modern vessels are normally equipped with a lot of electric instruments such as hydroacoustic systems, radars, navigation systems, and communication equipment. Any electric instruments may in some cases cause electrical interference and noise. International regulations and certifications are used to control and reduce this, but even these are limited if the electrical systems are poorly installed and/or maintained. Propeller noise Propeller noise is often the main source of noise at higher vessel speeds. Variable pitch propellers or fast moving propellers usually make more noise than fixed propellers or slow moving propellers. Propeller noise is usually water-borne. In some cases, however, shaft vibrations or vibrations in the hull near the propeller may be structure-borne to the transducer. If a propeller blade is damaged, this may increase the noise considerably. Propeller cavitation is a severe source of noise. "Singing" propellers might be a source of noise, which interferes at discrete frequencies. In some cases static discharge from the rotating propeller shaft may be quite disturbing. 58 467020/B Preparations Cavitation Cavitation is the formation of small air bubbles close to the transducer face. The bubbles appear because the local pressure becomes negative during parts of the acoustic pressure cycles. The cavitation threshold increases with the hydrostatic pressure. The noise is made when the bubbles implode. Cavitation noise may appear near extruding objects at higher speeds, but more often it is caused by the propellers. Propeller cavitation is a severe source of noise. The cavitation starts when the water flows in the same direction as the propeller blades. This is where the propeller blades move downwards. In some cases a resonant phenomenon is set up in a hole near the hull. This sound will have a discrete frequency, while all other flow noise will have a wide frequency spectrum. (Image from U. S. Navy in the public domain.) Flow noise The upper water layers of the sea contain a myriad of small air bubbles created by the breaking waves. When the hull moves through water it will cause a disturbance, and this will generate friction. The friction zone is called the flow boundary layer. The water flow in this boundary layer may be laminar or turbulent. • The laminar flow is a nicely ordered, parallel movement of the water. • The turbulent flow is a disorderly flow pattern, full of eddies. A Turbulent flow B Laminar flow C Air bubbles Air bubbles absorb and reflect the sound energy, and they may in worst cases block the sound transmission altogether. The boundary layer increases in thickness when it becomes turbulent. The boundary layer is thin in the forward part of the vessel hull, and increases as it moves aft. The 467020/B 59 Simrad SY50 Installation Manual thickness depends on ships speed and on the roughness of the hull. All objects sticking out from the hull, or dents in the hull, will disturb the flow and will increase the thickness of the boundary layer. When the flow speed is high, the turbulence can be violent enough to destroy the integrity of the water. Small voids or cavities in the water will occur and this is called cavitation. Rattle noise Rattle noise may be caused by loose objects in the vicinity of the transducer, like fixing bolts. The rattle may also come from loose objects inside the hull. Interference Interference from other hydroacoustic equipment on board the same vessel may be an annoying source of disturbance. Unless the same frequency is used for more than one piece of equipment only the transmitted pulse will contribute to the interference. In physics, interference is the phenomenon in which two waves superpose each other to form a resultant wave of greater or lower amplitude. Interference usually refers to the interaction of waves that are correlated or coherent with each other, either because they come from the same source or because they have the same or nearly the same frequency. Interference effects can be observed with all types of waves, for example, light, radio, acoustic, surface water waves or matter waves. https://en.wikipedia.org/wiki/Wave_interference — April 2016 Ambient noise Ambient noise is usually not a limiting factor to the performance of sonars and echo sounders. The ambient noise may be split up as follows: • Sea noise: Air bubbles, seismic disturbances, waves, boundary turbulence, etc. • Biological noise: Fish, mammals • Man made noise: Other vessels, interference • Precipitation noise: Heavy rain or hail In some areas, where many vessels operate together, the engine and propeller noise from other vessels may be disturbing. Interference from hydroacoustic instruments located in other vessels may also be a limiting factor. The sea noise depends on the weather conditions. In bad weather the sea noise can be quite high due to the waves. 60 467020/B Preparations Electrical self noise Electrical or electronic self noise is picked up or generated in any other part of the equipment than the transducer. The most common source of electrical self noise is hum. The hum is normally generated by a low quality power supply. It is then picked up by the transducer cables and/or sensitive electronic circuitry. At higher frequencies – where rather wide bandwidths are necessary – the noise from components, transistors or other analogue electronic may be a limiting factor. Reverberation When you transmit an acoustic pulse into the water to search for a target, echoes will also be returned from any other objects in the beam. The energy reflected from these "unwanted" objects is referred to as reverberation. Reverberation is generated when the echoes from your transmissions are reflected not only by fish and valid targets in the water, but also from the sea bottom and the sea surface. Reverberation is often regarded as noise. There are several types of reverberation. Volume reverberation The volume reverberation is caused by minute plankton and air-bubbles in the water. This reverberation has often daily cycles in intensity. Surface reverberation The surface reverberation depends on the weather condition and the waves. Bottom reverberation The bottom reverberation depends on the roughness and physical properties of the sea bottom. Reverberation is often a limiting factor, especially if you are searching for smaller targets. The echoes from the bottom will always depend on the sea bottom properties. How uneven the seabed is will affect the echoes. What kind of bottom you have under your vessel is also significant, as rock, mud or sand will provide different reverberation. The bottom reverberation usually makes it difficult to investigate targets located close to the seabed. Your current tilt setting will also have an effect on the reverberation. The echoes from the sea surface will vary with the current sea state and your current tilt setting. The illustration demonstrates how the sea bottom and the sea surface return echoes back to your sonar system. 467020/B 61 Simrad SY50 Installation Manual A In this situation you will be able to identify the upper school of fish, but the lower school will be hidden in the shadow of the seabed rock formation. B In this situation you will see several weak echoes from the waves and from the rock on the bottom, but you will still be able to identify the school of fish. The reverberation is caused by the transmission pulse itself. It can only be reduced by shortening the pulse duration or using a smaller beamwidth. Some means to reduce acoustic noise Several factors are contributing to the performance of the hydroacoustic equipment used on board a vessel. Careful planning of the installation may reduce the acoustic noise. Unfortunately, it is impossible to simply provide a number of specific procedures to reduce the noise. The physical location of the installation trunk and the hull unit is important. This depends on the vessel's design and construction, how the hull is shaped, and how the water runs along the hull. Other factors deal with other equipment mounted on board, and this will also be vessel dependant. At moderate ship speeds the machinery noise is usually dominant. At medium speeds the flow noise increases more rapidly and takes over, while at higher speed the propeller noise will be the main contributor. Note The information here must be considered as general advice. Each system installation must be handled separately depending on the hull design and the other electrical and mechanical systems installed on the vessel. Reducing flow noise The shape of the hull plating around the installation trunk opening must be as streamlined as possible. It is particularly important that the hull plating in front of the installation trunk is as smooth as possible. Important Be especially aware of bilge keels and sacrificial anodes. The keel must be rounded off without sharp edges. Neither extruding objects nor abrupt transitions must be present. 62 467020/B Preparations The fairing around the installation trunk must be streamlined. The transducer must be protruding far enough down to reach out of the boundary layer. Reducing machinery noise The hull unit must be installed far away from the engine room. The main engine and relevant auxiliary engines and equipment must be fixed to rigid foundations to avoid vibrations. Any hull structure that may vibrate must be damped or coated to reduce the vibrations. The use of shock absorbers or floating rafts may sometimes reduce this noise. The structure-borne noise may be reduced by isolation, for example by providing vibration clamping between the transducer and the hull structure. Reducing propeller noise The hull unit must be installed far away from the propellers. Sufficient clearance between the propellers and the hull, the rudder and the keel must be provided. Place the sacrificial anodes in places where the water flow is the least disturbed. Ensure that the propellers blades are correctly designed and without damages. The use of a baffle between the propellers and the transducer may reduce noise appreciably. Static discharges caused by the rotating propeller shaft may be removed by proper grounding or by mounting a coal brush from the shaft to vessel ground. Reducing rattle noise Ensure that no parts near the transducers can rattle as a result of water flow or vibrations. Reducing interference Interference from the transmission pulses from other hydroacoustic instruments on board the vessel is difficult to avoid. The problem may be reduced by choosing the working frequencies carefully and to some extent by separating the different transducers. On vessels with a large number of separate hydroacoustic systems installed and in simultaneous use, a separate synchronizing system (for example the K-Sync) should be considered. Reducing electrical noise Make sure that all units are properly grounded. This is important to avoid electrical noise. Use shielded cables with correct grounding. Separate the cables used by the SY50 system from other cables with high voltages, large currents or transients. Place all high voltage power cables in metal conduits. 467020/B 63 Simrad SY50 Installation Manual Installing the SY50 system hardware units Topics General safety rules, page 65 Installing the display, page 66 Installing the Nexcom NISE 3900E Processor Unit, page 67 Installing the Operating Panel (Mk2), page 69 Installing the Operating Panel (Mk3), page 71 Installing the Power Supply Unit, page 72 64 467020/B Installing the SY50 system hardware units General safety rules Safety is important. The safety precautions must be followed at all times during installation and maintenance work. WARNING The SY50 system operates on 24 VDC and/or 230 VAC (50/60 Hz). These voltages are potentially lethal! You must never work alone on high-voltage equipment! This equipment must be installed, adjusted, and serviced only by qualified electrical maintenance personnel familiar with the construction and operation of the equipment and the hazards involved. Failure to observe this precaution could result in bodily injury. Personnel requirements All personnel must be trained in relevant installation and maintenance work. Personal protection Installation personnel must wear suitable work clothes. The work clothes must not contain sufficient static to ignite. Always wear a hard hat and suitable protective footwear while handling heavy objects. Power and ground You must always turn off all power before installation or maintenance work on the SY50 system. Use the main circuit breaker, and label the breaker with a warning sign that informs others that maintenance or installation work is in progress on the system. For safety reasons, two persons must always be present during troubleshooting with power turned ON. All SY50 system units must be properly grounded. First aid Read and understand the applicable first aid instructions related to electric shock. Whenever installation or maintenance work is in progress, it is essential that a first aid kit is available. All personnel must be familiar with the first aid instructions for electrical shock and other personal injuries. Weight The various parts of the system may be heavy. Make sure that the appropriate tools and certified lifting equipment are available. Always wear a hard hat and suitable protective footwear while handling heavy objects. Cables Each electric cable must be handled carefully. This is important to avoid damage to the cable. This is also important to avoid electric shock in the event that the cable is unintentionally connected to a power source. 467020/B 65 Simrad SY50 Installation Manual Cabinets Do not open racks or cabinet doors while sailing in rough seas. Doors and/or cabinet parts may suddenly swing open and cause damage or injury. Related topics Simrad SY50, page 13 Preparations, page 39 Installing the SY50 system hardware units, page 64 Installing the hull unit, page 88 Installing the display A display is a required part of the SY50 system. For best readability, the display must be protected from glare and have the correct height and angle. The display is normally not included with the SY50 system delivery. A generic procedure is provided. Prerequisites You must be equipped with a standard set of tools. This tool set must comprise the normal tools for electronic and electromechanical tasks. This includes different screwdriver types, pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in various sizes. We recommend that all tools are demagnetized to protect your equipment. A suitable location for the display must be defined before installation. If you place the unit on the bridge, observe the compass safe distance. Procedure 1 Prepare the location and the necessary tools. 2 Observe the installation requirements. a Check the installation requirements provided by the manufacturer. b Position the display so that it is best protected from glare which reduces readability. c Observe the compass safe distance. d Make sure that enough space is made available for maintenance purposes. e Make sure that adequate ventilation is available to avoid overheating. f Make sure that the installation method allows for the physical vibration, movements and forces normally experienced on a vessel. Note To allow future maintenance, you must mount the unit with its cables and connectors available for easy access. 66 467020/B Installing the SY50 system hardware units 3 Make sure that the chosen location meets the installation requirements. 4 Install the display as described in the applicable documentation provided by the manufacturer. 5 Connect the cables. Note When you connect the cables, make sure that they are all properly secured, and able to withstand the vibration and movements of the vessel. Related topics Installing the SY50 system hardware units, page 64 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 Installing the Nexcom NISE 3900E Processor Unit The Processor Unit can be installed inside a console, inside a suitable cabinet, in a 19" rack or on a desk. Make sure that ample ventilation is provided to avoid overheating. A dedicated installation procedure is provided. Prerequisites You must be equipped with a standard set of tools. This tool set must comprise the normal tools for electronic and electromechanical tasks. This includes different screwdriver types, pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in various sizes. We recommend that all tools are demagnetized to protect your equipment. A suitable location for the Processor Unit must be defined before installation. Observe the compass safe distance. Procedure 1 Prepare the location and the necessary tools. 2 Observe the installation requirements. a Depending on its physical properties, install the computer inside a console, in a cabinet or 19” rack, or on a desk. 467020/B 67 Simrad SY50 Installation Manual b Choose a position to fit the available cable lengths between the computer and the other units it connects to. c Observe the compass safe distance. d Make sure that enough space is made available for maintenance purposes. e Make sure that adequate ventilation is available to avoid overheating. f Make sure that the installation method allows for the physical vibration, movements and forces normally experienced on a vessel. Note To allow future maintenance, you must mount the unit with its cables and connectors available for easy access. 3 Make sure that the chosen location meets the installation requirements. 4 Provide ample space around the computer. You must be able to reach and use the front and rear mounted connectors and on/off switches. It is also important that you allow for easy access to all the computer cables, and enough space for inspection, maintenance and parts replacement. If relevant: Make sure that the space allows you to open the computer for unobstructed access to its internal parts. Note Make sure that you can access both the rear and front side of the computer after it has been installed. 5 Install the Processor Unit. The computer is fitted with mounting brackets on each side. Use these brackets to secure the computer to the surface. 6 Connect the cables. Note Do not connect the Processor Unit to AC mains. When you connect the cables, make sure that they are all properly secured, and able to withstand the vibration and movements of the vessel. Related topics Installing the SY50 system hardware units, page 64 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 Nexcom NISE 3900E Outline dimensions, page 294 68 467020/B Installing the SY50 system hardware units Installing the Operating Panel (Mk2) The Operating Panel offers all necessary control functions for normal operation. The Operating Panel is normally placed on the bridge near the display. Prerequisites You must be equipped with a standard set of tools. This tool set must comprise the normal tools for electronic and electromechanical tasks. This includes different screwdriver types, pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in various sizes. We recommend that all tools are demagnetized to protect your equipment. Depending on the chosen installation method, additional tools may be required. A small hex key is required to remove and replace the wrist support. The tool is provided with the delivery. Size: 0.9 mm. Context The SY50 system supports two different operating panels. These are referred to as "Mk2" and "Mk3". • The Mk2 Operating Panel is connected to the Processor Unit using an Ethernet cable. • The Mk3 Operating Panel is connected to the Processor Unit with a USB cable. The Mk3 Operating Panel is the standard panel provided for the SY50 system. A suitable location for the Operating Panel must be chosen before the installation starts. Observe the limitations due to the cable lengths. We recommend that the Operating Panel is positioned in the same physical direction as the display, so that "up" on the operating panel is the same as "up" on the display. Experience has shown that this will make it easier to use the trackball on the operating panel when you wish to control the cursor on the display. Procedure 1 Prepare the location and the necessary tools. Note To allow future maintenance, you must mount the unit with its cables and connectors available for easy access. 2 Drill and cut the panel opening as shown in drawing (204688). 467020/B 69 Simrad SY50 Installation Manual 3 4 If the wrist support has been previously mounted, remove it. a Insert the hex key (B) into the assigned hole (A) and remove the screw. b Pull the wrist support straight "down" as indicated by the arrow. c Make sure that you do not loose the small screw and the lid. Mount the Operating Panel using the supplied hardware. The necessary mounting hardware (four screws, four nut plates and four bolt covers) are supplied in the standard delivery. 5 70 a Position the four nut plates shown in the illustration. b Use a 3 mm Allen key to fasten the four special bolts. c Mount the bolt covers in the four corners of the Operating Panel. Mount the wrist support. a Slide the support straight "up" onto the mounting block (B) as indicated by the arrow. b Insert the lid with the hook (C) first, the press it firmly in. c Use the hex key to insert the screw in the assigned hole (A). 467020/B Installing the SY50 system hardware units 6 Connect the cables. Note When you connect the cables, make sure that they are all properly secured, and able to withstand the vibration and movements of the vessel. Related topics Installing the SY50 system hardware units, page 64 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 440689 Operating Panel cut-out drawing( Mk2), page 312 443179 Operating Panel dimensions (Mk2), page 313 439594 Operating Panel adapter plate (Mk2), page 316 Installing the Operating Panel (Mk3) The Operating Panel offers all necessary control functions for normal operation. The Operating Panel is normally placed on the bridge near the display. Prerequisites You must be equipped with a standard set of tools. This tool set must comprise the normal tools for electronic and electromechanical tasks. This includes different screwdriver types, pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in various sizes. We recommend that all tools are demagnetized to protect your equipment. Depending on the chosen installation method, additional tools may be required. Context The SY50 system supports two different operating panels. These are referred to as "Mk2" and "Mk3". • The Mk2 Operating Panel is connected to the Processor Unit using an Ethernet cable. • The Mk3 Operating Panel is connected to the Processor Unit with a USB cable. The Mk3 Operating Panel is the standard panel provided for the SY50 system. A suitable location for the Operating Panel must be chosen before the installation starts. Observe the limitations due to the cable lengths. We recommend that the Operating Panel is positioned in the same physical direction as the display, so that "up" on the operating panel is the same as "up" on the display. Experience has shown that this will make it easier to use the trackball on the operating panel when you wish to control the cursor on the display. 467020/B 71 Simrad SY50 Installation Manual Procedure 1 Prepare the location and the necessary tools. Note To allow future maintenance, you must mount the unit with its cables and connectors available for easy access. 2 Drill and cut the panel opening as shown in drawing 476352. 3 Mount the Operating Panel using the supplied hardware. The necessary mounting hardware (four screws, four nut plates and four bolt covers) are supplied in the standard delivery. 4 a Position the four nut plates shown in the illustration. b Use a 3 mm Allen key to fasten the four special bolts. c Mount the bolt covers in the four corners of the Operating Panel. Connect the USB cable to the Operating Panel. Note When you connect the cable, make sure that it is properly secured, and able to withstand the vibration and movements of the vessel. Related topics Installing the SY50 system hardware units, page 64 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 476352 Operating Panel dimensions (Mk3), page 309 Installing the Power Supply Unit A dedicated power supply unit is provided with the SY50 system. The purpose of the Power Supply Unit is to provide the hull unit with the necessary power for operation. The Power Supply Unit also controls the Ethernet communication between the transducer and the Processor Unit. Prerequisites You must be equipped with a standard set of tools. This tool set must comprise the normal tools for electronic and electromechanical tasks. This includes different screwdriver types, pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in various sizes. We recommend that all tools are demagnetized to 72 467020/B Installing the SY50 system hardware units protect your equipment. Depending on the chosen installation method, additional tools may be required. Context A suitable location for the unit must be defined before the installation can start. Free bulkhead space is required. Any location can be used, provided that the cables are long enough, and that the ventilation is adequate. The chosen location must allow ample space for installation and maintenance tasks. Make sure that the cabinet door can be fully opened for unrestricted access. Note By default, the SY50 system uses a built-in motion sensor. It is located inside the Power Supply Unit. The information provided by the motion sensor is used by the SY50 system to stabilize the beams. For this reason we recommend that the Power Supply Unit is mounted as vertically as possible, and with the cabinet door facing forward. Observe the physical size and weight of the Power Supply Unit. Unless a suitable lifting device available, make sure that enough manpower is available to lift, hold and fasten the Power Supply Unit. Avoid installation heights exceeding two metres. Procedure 1 Prepare the location and the necessary tools. Note To allow future maintenance, you must mount the unit with its cables and connectors available for easy access. Make sure that the cabinet door can be fully opened for unrestricted access. We recommend that you mount the Power Supply Unit as vertically as possible, and with the cabinet door facing forward. 2 Define the location of the mounting bolts. Refer to drawing 462682. 3 Mount the Power Supply Unit on the bulkhead using bolts through the mounting holes. 4 Measure and record the installation angles (X, Y and Z) for the unit. Do this as accurately as possible. The information is used to set up the correct installation parameters for the motion sensor. 5 Connect the cables. Note Do not connect the Power Supply Unit to AC mains. When you connect the cables, make sure that they are all properly secured, and able to withstand the vibration and movements of the vessel. 467020/B 73 Simrad SY50 Installation Manual Related topics Installing the SY50 system hardware units, page 64 Cable layout and interconnections, page 125 Setting to work, page 162 Technical specifications, page 274 Drawing file, page 292 462682 Power Supply Unit dimensions, page 296 74 467020/B Mounting the installation trunk Mounting the installation trunk Topics Installation summary, page 76 About the installation trunk, page 78 Mounting the installation trunk, page 83 Verifying the quality of the installation, page 85 467020/B 75 Simrad SY50 Installation Manual Installation summary The installation trunk provides the physical foundation for the entire hull unit. Prerequisites This task must take place in dry dock. The shipyard must provide all necessary tools and manpower. Appropriate lifting equipment (lifting tackle, portable crane or ship’s crane) is required. Free access through the hull or the decks over the installation trunk must be provided. Note The installation trunk is heavy. Appropriate lifting equipment (lifting tackle, portable crane or ship’s crane) is required. Always use appropriate lifting equipment to minimize risk of personnel injury or equipment damages. Only certified equipment must be used. Context Only the basic steps of the task are offered. For more information, refer to the other descriptions and tasks in this chapter. Note The top mating surface of the installation trunk must be protected with a blind flange or wooden cover at all times until the hull unit is installed. The quality of the welding is critical to the safety of the vessel. Welding must only be done by a certified welder. Always wear the personal protective equipment. Observe and obey the relevant safety instructions. The final installation work must be approved by the vessel’s national registry, the corresponding maritime authority and/or classification society. The installation trunk - with a blind flange - can be ordered from Kongsberg Maritime as an optional delivery. As an alternative, the installation trunk can be manufactured by the shipyard based on the drawings in this manual. A locally manufactured installation trunk can be adjusted to better fit the properties of the vessel’s hull.The height of the installation trunk must be adjusted to fit the specific installation requirements of the vessel. An existing installation trunk can be used. You may need to reduce the length of the transducer shaft. The length depends on the height of your installation trunk and the lowering depth of the transducer. Use the following equation to calculate the length (in millimetres): [Required length of transducer shaft] = [Height of installation trunk] + 400 Procedure 1 76 Define the physical location of the installation trunk. 467020/B Mounting the installation trunk 2 Cut out a hole in the vessel’s hull with a diameter large enough to accommodate the installation trunk. 3 Orientate the installation trunk correctly, and then weld it into position. 4 Brace the installation trunk to the hull plating and the surrounding hull frames by adding several strengthening plates. 5 Depending on the shape of the hull, we recommend that you fit a steel blister for protection. 6 Inspect the installation of the installation trunk, the blister, hull plating and all surfaces thoroughly. Related topics Mounting the installation trunk, page 83 Verifying the quality of the installation, page 85 Length of transducer shaft versus height of installation trunk, page 80 467020/B 77 Simrad SY50 Installation Manual About the installation trunk The installation trunk provides the physical foundation for the entire hull unit. The installation trunk penetrates the hull. The installation trunk is therefore a crucial part of the hull unit assembly. In order to ensure proper operation of the SY50 system, the physical location of the installation trunk must be carefully selected. An existing installation trunk can be used. The installation trunk - with a blind flange - can be ordered from Kongsberg Maritime as an optional delivery. As an alternative, the installation trunk can be manufactured by the shipyard based on the drawings in this manual. A locally manufactured installation trunk can be adjusted to better fit the properties of the vessel’s hull. Note The optional installation trunk offered by Kongsberg Maritime is approved by Det Norske Veritas (DNVGL), and includes a blind flange and a rubber gasket. If the installation trunk is manufactured locally, the installation shipyard is responsible for obtaining the approval certificates from the relevant national registry. You may need to reduce the length of the transducer shaft. The length depends on the height of your installation trunk and the lowering depth of the transducer. Use the following equation to calculate the length (in millimetres): [Required length of transducer shaft] = [Height of installation trunk] + 400 Topics Rubber gasket, page 78 Mechanical support brackets, page 79 Design and installation drawings, page 80 Length of transducer shaft versus height of installation trunk, page 80 Rubber gasket A dedicated gasket is provided with the delivery. This gasket ensures a watertight connection between the installation trunk and the bottom of the transducer shaft sleeve. During the installation process, make sure that the gasket is kept safe from damage, and that the top of the installation trunk is kept clean, smooth and without physical damage such as scratches or dents. 78 467020/B Mounting the installation trunk Note Make sure that the gasket is undamaged without cracks or signs of wear. Make sure that the gasket is NOT covered with grease or lubricants. If you suspect that the gasket is damaged, replace it. If the gasket has been contaminated with dirt, grease or lubricants, it must be replaced. Related topics Mounting the installation trunk, page 75 About the installation trunk, page 78 Mechanical support brackets Due to its physical size and weight, and the fact that the installation trunk penetrates the vessel hull, it is very important that the hull unit is installed and secured properly. A Strengthening knee-plates (stiffereners) B Installation trunk Important The hull unit gantry must be secured to the bulkhead by means of mechanical support brackets. The dimensions and strength of the support brackets must be adequate to prevent vortex induced vibration. This a requirement to ensure the safety of the SY50 system and the vessel. The forces to which the hull unit is exposed depends on the physical size of the installation, where it is located, and the vessel's behaviour in rough sea. It is very important that the hull unit is sufficiently supported, as the forces it is exposed to may affect both the physical installation and the vessel's safety. 467020/B 79 Simrad SY50 Installation Manual The mechanical support brackets must be designed and manufactured by the installation shipyard to fit the complete installation in the sonar room. All calculations made to support the design must meet the applicable safety requirements, and apply to the physical properties of the hull and the installation. Note The final design and the installation must be approved by the classification society. Without a proper mechanical support for the hull unit gantry, the guarantee will be void! Related topics Mounting the installation trunk, page 75 About the installation trunk, page 78 Design and installation drawings The installation shipyard must provide all necessary design and installation drawings, as well as the relevant work standards and mounting procedures. If required, all documents provided by the shipyard for the physical installation of the SY50 system must be approved by the vessel’s national registry and corresponding maritime authority and/or classification society. Such approval must be obtained before the installation can begin. The shipowner and shipyard doing the installation are responsible for obtaining and paying for such approval. Related topics Mounting the installation trunk, page 75 About the installation trunk, page 78 Length of transducer shaft versus height of installation trunk The hull unit can be placed on new or existing installation trunks with different heights. The height of the installation trunk and the length of the transducer shaft can be adjusted to fit the size of the vessel. You may need to reduce the length of the transducer shaft. The length depends on the height of your installation trunk and the lowering depth of the transducer. Use the following equation to calculate the length (in millimetres): [Required length of transducer shaft] = [Height of installation trunk] + 400 80 467020/B Mounting the installation trunk Transducer lowered to 400 millimetres Transducer shaft: 1300 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 600 1000 300 650 1050 250 700 1100 200 Transducer lowered to 600 millimetres Transducer shaft: 1300 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 750 1150 150 800 1200 100 850 1250 50 900 1300 0 Transducer shaft: 1550 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 950 1350 200 1000 1400 150 1100 1450 50 Transducer shaft: 2350 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 1200 1600 750 1300 1700 650 1400 1800 550 1500 1900 450 1600 2000 350 1700 2100 250 1800 2200 150 1900 2300 50 Transducer shaft: 4000 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 2000 2400 1600 2100 2500 1500 2200 2600 1400 467020/B 81 Simrad SY50 Installation Manual Transducer shaft: 4000 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 2300 2700 1300 2400 2800 1200 2500 2900 1100 2600 3000 1000 2700 3100 900 2800 3200 800 2900 3300 700 3000 3400 600 3100 3500 500 3200 3600 400 3300 3700 300 3400 3800 200 3500 3900 100 3600 4000 0 Related topics Mounting the installation trunk, page 75 About the installation trunk, page 78 About the hull unit installation, page 94 Installing the hull unit, page 88 Cutting the transducer shaft, page 103 82 467020/B Mounting the installation trunk Mounting the installation trunk The installation trunk must be mounted so that it remains vertical during normal operating conditions. Prerequisites The installation trunk is heavy. Always use appropriate lifting equipment to minimize risk of personnel injury or equipment damages. Only certified equipment must be used. Illustration: The centre line of the trunk (!) must be parallel with the vessel’s centre line. Context Only the basic steps of the task are offered. Additional procedures with more information and/or details must be provided by the installation shipyard to fit the vessel properties. The top mating surface of the installation trunk must be protected with a blind flange or wooden cover at all times until the hull unit is installed. Note The quality of the welding is critical to the safety of the vessel. Welding must only be done by a certified welder. Always wear the personal protective equipment. Observe and obey the relevant safety instructions. The final installation work must be approved by the vessel’s national registry, the corresponding maritime authority and/or classification society. Procedure 1 Define the physical location of the installation trunk. This location must be carefully selected. The decision must be based on the general principles outlined in chapter Preparations and all relevant knowledge about the vessel construction. Note All information related to practical and theoretical noise patterns along the hull must be taken into consideration. 2 Note the orientation of the centre line of the installation trunk with regards to the mounting bolts. 467020/B 83 Simrad SY50 Installation Manual 3 Remove the rubber gasket from the top of the installation trunk to protect it from the heat. 4 Cut out a hole in the vessel’s hull with a diameter large enough to accommodate the installation trunk. The exact size of the hole must be determined by the installation shipyard. 5 Orientate the installation trunk correctly, and then weld it into position. Observe the installation examples to select the height from the top of the trunk flange and down to the underside of the protection blister. Important To obtain optimal SY50 system performance, the total height of the installation trunk must be as close as possible to its stated minimum height. The top flange must be parallel to the water line in both the fore-and-aft and athwartship directions. 6 Make sure that the upper surface of the installation trunk is level, undamaged and clean. 7 Cover the upper surface of the installation trunk with a blind flange or wooden plate to protect it. 8 Brace the installation trunk to the hull plating and the surrounding hull frames by adding several strengthening plates. The plates must be at least 1.5 times as thick as the surrounding shell plating. The final dimensions of the doubling plate must be defined in the approved installation drawings supplied by the shipyard. 9 84 Stiffen the installation trunk in both the fore-and-aft and athwartship directions by welding strengthening knee-plates both to the trunk and to the doubling plate. A Strengthening knee-plates (stiffereners) B Installation trunk 467020/B Mounting the installation trunk 10 Depending on the shape of the hull, we recommend that you fit a steel blister for protection. The blister must be designed by the installation shipyard. It must be welded to the shell plating. The blister may be an open type, or it can be filled with oil to prevent corrosion. This last method provides excellent protection, and simplifies maintenance. Note Make sure that the hull plating surrounding the trunk is even and smooth without protruding objects that can cause noise. Objects protruding from the hull will generate turbulence and flow noise. This will reduce the overall performance of your system. If necessary, grind and polish all surfaces. 11 As soon as all installation, welding and grinding has been done, prime or paint the trunk and the surrounding area using a high quality protective coating. Note You must also apply the protective coating to the inside of the installation trunk. 12 Inspect the installation of the installation trunk, the blister, hull plating and all surfaces thoroughly. Related topics Mounting the installation trunk, page 75 Verifying the quality of the installation Once the installation trunk and blister have been installed, a quality inspection must take place. The purpose of the inspection is to makes sure that the installation trunk has been installed correctly, and that the hull unit can be mounted on top of it. Prerequisites Neither tools nor instruments are required. Context The installation trunk must be mounted so that it remains vertical during normal operating conditions. The top mating surface of the installation trunk must be protected with a blind flange or wooden cover at all times until the hull unit is installed. It is very important that this surface is clean and undamaged. It must be watertight after the hull unit has been installed. 467020/B 85 Simrad SY50 Installation Manual Objects protruding from the hull will generate turbulence and flow noise. This will reduce the overall performance of your system. Protruding objects may be zinc anodes, transducers or even the vessel's keel. Holes and pipe outlets are also important noise sources, as well as rough surfaces caused by bad welding. Even traces of sealing compound, sharp edges, bolts or empty bolt holes will create noise. Procedure 1 Write down the key measurements. This is for future reference. • Horizontal distance from the keel to the centre of the installation trunk • Height from the bottom of keel to the top of the installation trunk • Total height of the installation trunk (with optional blister) 2 Do a close visual inspection of the physical properties of the installation trunk and the way it has been installed. Refer to the applicable requirements. 3 a Make sure that the upper surface of the installation trunk is level, undamaged and clean. b Make sure that the installation trunk has been properly stiffened in both the fore-and-aft and athwartship directions by means of strengthening knee plates. c Make sure that the installation trunk has been properly braced to the hull plating and the surrounding hull frames. Do a close visual inspection of the blister and the hull plating close to the installation trunk. Check for any kind of objects that may cause noise. 4 Make sure that all surfaces are protected with a high quality coating. 5 Make sure that the inside of the installation trunk is also protected with coating. 6 Fill in the result tables. Result Horizontal distance from the keel to the centre of the installation trunk Height from the bottom of keel to the top of the installation trunk Requirements Total height of the installation trunk (with optional blister) Results All measurements are made and the results are written down. The top of the installation trunk is in parallel with the water line. 86 467020/B Mounting the installation trunk Requirements Results The top surface of the installation trunk is clean without sand, dust or any other destructive particles. Is is even and smooth without scratches, dents or other physical damage. The installation trunk has been properly stiffened in both the fore-and-aft and athwartship directions by means of strengthening knee plates. The installation trunk has been properly braced to the hull plating and the surrounding hull frames. The hull plating surrounding the installation trunk is even and smooth without protruding objects that can cause noise. The gasket is not damaged. All surfaces (including the inside of the trunk) are protected using a high quality coating. Date and signature: Further requirements If the inspection reveals errors, inaccuracies or unfortunate dispositions related to units, devices or cables, use the Installation remarks form to document these. If necessary, write a full report, and attach high resolution photos. Related topics Mounting the installation trunk, page 75 467020/B 87 Simrad SY50 Installation Manual Installing the hull unit Topics Installation summary, page 89 General safety rules, page 91 Hull unit familiarization, page 93 About the hull unit installation, page 94 Installation procedures, page 100 Hull unit and transducer alignment, page 124 88 467020/B Installing the hull unit Installation summary The hull unit is crucial part of the sonar system. Due to its physical size and weight, and the fact that the installation trunk penetrates the vessel hull, it is very important that the hull unit is installed and secured properly. Prerequisites The shipyard must provide all necessary tools and manpower. Before you install the hull unit, you must have mounted and prepared the installation trunk. Free access through the hull or the decks over the installation trunk must be provided. Note Appropriate lifting equipment (lifting tackle, portable crane or ship’s crane) may be required. Always use appropriate lifting equipment to minimize risk of personnel injury or equipment damages. Only certified equipment must be used. The vessel is berthed or in dry dock. Context Only the basic steps of the task are offered. For more information, refer to the other descriptions and tasks in this chapter. Note • The hull unit, transducer and transducer cable must be handled with care. • The transducer is covered with a thick red or black protective coating made of a special plastic type. The protective coating is a vital part of the transducer. It is very important that neither this coating nor the internal parts of the transducer are damaged during the handling, installation or cleaning. Any holes and/or scratches in the transducer surface will allow water to penetrate the transducer. If a leak occurs, the transducer must be replaced. • The top mating surface of the installation trunk must be protected with a blind flange or wooden cover at all times until the hull unit is installed. It is very important that this surface is clean and undamaged. It must be watertight after the hull unit has been installed. Procedure 1 Unpack all the parts and familiarize yourself with the design and the assembly. 2 Inspect the transducer closely for any signs of dents, cracks, fractures or holes. 3 If necessary: Cut the transducer shaft to the correct length. 4 Make recesses for the cable gland set screws at the top of the transducer shaft. 5 Mount the transducer flange to the bottom of the transducer shaft. 467020/B 89 Simrad SY50 Installation Manual 6 Mount the trunk bearing onto the transducer shaft. 7 Push the transducer shaft carefully up through the mounting flange and the transducer shaft sleeve. Mount the gantry. 8 Pull the transducer cable up through the transducer shaft. Mount the transducer using the bolts provided. 9 Mount the hull unit on top of the installation trunk. 10 Add grease to the transducer shaft sleeve. Tighten the bolts. 11 Connect the control cable between the Power Supply Unit and the junction box. This is described in the Cable layout and interconnections chapter. 12 Secure all cables, so that the connections can withstand the vibration and movements of the vessel. 13 Do a close visual inspection of the entire hull unit installation to verify the quality of the work. Related topics Installing the hull unit, page 88 462683 Hull Unit dimensions SY50, page 299 489609 Hull Unit dimensions SY50C, page 302 90 467020/B Installing the hull unit General safety rules Safety is important. The safety precautions must be followed at all times during installation and maintenance work. WARNING The SY50 system operates on 24 VDC and/or 230 VAC (50/60 Hz). These voltages are potentially lethal! You must never work alone on high-voltage equipment! This equipment must be installed, adjusted, and serviced only by qualified electrical maintenance personnel familiar with the construction and operation of the equipment and the hazards involved. Failure to observe this precaution could result in bodily injury. Personnel requirements All personnel must be trained in relevant installation and maintenance work. Personal protection Installation personnel must wear suitable work clothes. The work clothes must not contain sufficient static to ignite. Always wear a hard hat and suitable protective footwear while handling heavy objects. Power and ground You must always turn off all power before installation or maintenance work on the SY50 system. Use the main circuit breaker, and label the breaker with a warning sign that informs others that maintenance or installation work is in progress on the system. For safety reasons, two persons must always be present during troubleshooting with power turned ON. All SY50 system units must be properly grounded. First aid Read and understand the applicable first aid instructions related to electric shock. Whenever installation or maintenance work is in progress, it is essential that a first aid kit is available. All personnel must be familiar with the first aid instructions for electrical shock and other personal injuries. Weight The various parts of the system may be heavy. Make sure that the appropriate tools and certified lifting equipment are available. Always wear a hard hat and suitable protective footwear while handling heavy objects. Cables Each electric cable must be handled carefully. This is important to avoid damage to the cable. This is also important to avoid electric shock in the event that the cable is unintentionally connected to a power source. 467020/B 91 Simrad SY50 Installation Manual Cabinets Do not open racks or cabinet doors while sailing in rough seas. Doors and/or cabinet parts may suddenly swing open and cause damage or injury. Related topics Simrad SY50, page 13 Preparations, page 39 Installing the SY50 system hardware units, page 64 Installing the hull unit, page 88 92 467020/B Installing the hull unit Hull unit familiarization The hull unit is used to lower the transducer down below the ship’s hull when the SY50 system shall be used. When the SY50 system is turned off, the transducer is hoisted for protection. The upper parts of the hull unit include the mechanical gantry, the hoisting motor, the hoisting spindle and the junction box. The transducer shaft is supported by the gantry, and penetrates the transducer shaft sleeve and the mounting flange. The complete assembly is mounted on the top of the installation trunk. The transducer is bolted to the bottom of the transducer shaft using a transducer flange. The transducer cable is placed inside the transducer shaft. A Cable gland B Top cover C Lifting clamp D Hoisting motor E Transducer shaft F Hoisting spindle G Junction box H Control cable I Transducer cable J Gantry K Transducer shaft sleeve L Mounting flange M Trunk bearing N Installation trunk O Transducer flange P Transducer Related topics Installing the hull unit, page 88 467020/B 93 Simrad SY50 Installation Manual About the hull unit installation The hull unit is used to lower the transducer down below the ship’s hull when the SY50 system shall be used. When the SY50 system is turned off, the transducer is hoisted for protection. The hull unit is crucial part of the sonar system. The hull unit shall be mounted on top of the installation trunk at the bottom of the hull. The installation trunk penetrates the ship’s hull, and allows the transducer to be lowered into the sea. The hull unit is normally located in the forward part of the vessel. As a general recommendation, the hull unit shall be oriented with the hoisting motor pointing approximately 45 degrees of the vessel’s centre line. If this orientation makes it difficult to access electrical connections, the hull unit may be rotated during its installation to the most suitable direction. Note Do not place the hull unit with the hoisting motor facing aft or forward. Do not place the hull unit with the hoisting motor facing port or starboard. Appropriate lifting equipment (lifting tackle, portable crane or ship’s crane) may be required. Free access through the hull or the decks over the installation trunk must be provided. Topics Rubber gasket, page 94 Design and installation drawings, page 95 Length of transducer shaft versus height of installation trunk, page 95 Rotating the mounting flange on the installation trunk, page 97 Rubber gasket A dedicated gasket is provided with the delivery. This gasket ensures a watertight connection between the installation trunk and the bottom of the transducer shaft sleeve. During the installation process, make sure that the gasket is kept safe from damage, and that the top of the installation trunk is kept clean, smooth and without physical damage such as scratches or dents. Note Make sure that the gasket is undamaged without cracks or signs of wear. Make sure that the gasket is NOT covered with grease or lubricants. If you suspect that the gasket is damaged, replace it. If the gasket has been contaminated with dirt, grease or lubricants, it must be replaced. 94 467020/B Installing the hull unit Related topics About the hull unit installation, page 94 Installing the hull unit, page 88 Design and installation drawings The installation shipyard must provide all necessary design and installation drawings, as well as the relevant work standards and mounting procedures. If required, all documents provided by the shipyard for the physical installation of the SY50 system must be approved by the vessel’s national registry and corresponding maritime authority and/or classification society. Such approval must be obtained before the installation can begin. The shipowner and shipyard doing the installation are responsible for obtaining and paying for such approval. Related topics About the hull unit installation, page 94 Installing the hull unit, page 88 Length of transducer shaft versus height of installation trunk The hull unit can be placed on new or existing installation trunks with different heights. The height of the installation trunk and the length of the transducer shaft can be adjusted to fit the size of the vessel. You may need to reduce the length of the transducer shaft. The length depends on the height of your installation trunk and the lowering depth of the transducer. Use the following equation to calculate the length (in millimetres): [Required length of transducer shaft] = [Height of installation trunk] + 400 Transducer lowered to 400 millimetres Transducer shaft: 1300 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 600 1000 300 650 1050 250 700 1100 200 467020/B 95 Simrad SY50 Installation Manual Transducer lowered to 600 millimetres Transducer shaft: 1300 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 750 1150 150 800 1200 100 850 1250 50 900 1300 0 Transducer shaft: 1550 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 950 1350 200 1000 1400 150 1100 1450 50 Transducer shaft: 2350 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 1200 1600 750 1300 1700 650 1400 1800 550 1500 1900 450 1600 2000 350 1700 2100 250 1800 2200 150 1900 2300 50 Transducer shaft: 4000 mm 96 Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 2000 2400 1600 2100 2500 1500 2200 2600 1400 2300 2700 1300 2400 2800 1200 2500 2900 1100 2600 3000 1000 2700 3100 900 2800 3200 800 2900 3300 700 467020/B Installing the hull unit Transducer shaft: 4000 mm Height of installation trunk (mm) Required length of transducer shaft (mm) Reduce the shaft length with: (mm) 3000 3400 600 3100 3500 500 3200 3600 400 3300 3700 300 3400 3800 200 3500 3900 100 3600 4000 0 Related topics Mounting the installation trunk, page 75 About the installation trunk, page 78 About the hull unit installation, page 94 Installing the hull unit, page 88 Cutting the transducer shaft, page 103 Rotating the mounting flange on the installation trunk As a general recommendation, the hull unit shall be oriented with the hoisting motor pointing approximately 45 degrees of the vessel’s centre line. If this orientation makes it difficult to access electrical connections, the hull unit may be rotated during its installation to the most suitable direction. Note Do not rotate the mounting flange so that the hoisting motor and gantry is placed in parallel to or across the longitudinal direction of the vessel. 467020/B 97 Simrad SY50 Installation Manual A We recommend that you rotate the mounting flange and transducer shaft sleeve so that the air vent plug points forward. B Do not rotate the mounting flange so that the hoisting motor and gantry is placed in parallel to or across the longitudinal direction of the vessel. C All other rotation angles are permitted. D Air vent plug E Mounting brackets for gantry F Grease nipple G Pressure release plug The properties of the sonar room may prevent you from rotating the mounting flange to the recommended angle. Any rotation angles - except those specified - are accepted if it is necessary to obtain ample space for installation, maintenance and replacement of parts. Note Do not place the hull unit with the hoisting motor facing aft or forward. Do not place the hull unit with the hoisting motor facing port or starboard. 98 467020/B Installing the hull unit Related topics About the hull unit installation, page 94 Installing the hull unit, page 88 467020/B 99 Simrad SY50 Installation Manual Installation procedures Topics Unpacking the hull unit from its transport box, page 101 Unpacking the transducer from its transport crate, page 102 Cutting the transducer shaft, page 103 Making recesses for the set screws used to mount the cable gland assembly, page 105 Mounting the transducer flange, page 106 Mounting the trunk bearing, page 108 Mounting the gantry, page 111 Mounting the transducer, page 114 Mounting the hull unit on top of the installation trunk, page 116 Lubricating the transducer shaft sleeve, page 117 Inspecting the transducer, page 119 Verifying the quality of the hull unit installation, page 122 100 467020/B Installing the hull unit Unpacking the hull unit from its transport box The hull unit is delivered in a wooden transport box. The box includes the Power Supply Unit. The transducer and the transducer shaft are supplied separately. Context The hull unit, transducer and transducer cable must be handled with care. A Gantry B Cable gland (assembly) • Bushing • Rubber gasket • Packing nipple • Washers (2) • Set screws (3) • O-ring (45 mm) C Transducer shaft sleeve / Mounting flange • Mounting bolts (20 mm) • Nuts • Spring lock washers • Washers D Rubber gasket E Trunk bearing F Transducer flange • Set screws(3) • O-ring (32 mm) G Transducer shaft H Transducer • Mounting bolts (8 mm) • O-ring (90 mm) Procedure • Unpack and identify each item. 467020/B 101 Simrad SY50 Installation Manual Related topics Installation procedures, page 100 Installing the hull unit, page 88 Unpacking the transducer from its transport crate The SY50 transducer is shipped in a wooden box. It rests on a protective cushion shaped to fit the transducer face. Context A transducer must always be handled as a delicate instrument. Incorrect actions may damage the transducer beyond repair. Observe these transducer handling rules: • Do not activate the transducer when it is out of the water. • Do not handle the transducer roughly. Avoid impacts. • Do not expose the transducer to direct sunlight or excessive heat. • Do not use high-pressure water, sandblasting, metal tools or strong solvents to clean the transducer. • Do not damage the outer protective skin of the transducer. • Do not damage the outer protective skin of the transducer face. • Do not step on the transducer cable. • Do not damage the transducer cable. Avoid exposure to sharp objects. Procedure 1 Open the shipping box. Note Be careful! Do not use heavy tools. Do not use excessive force. Make sure that you do not damage the transducer or the cable. 2 Lift the transducer straight up and out of the box. Note DO NOT lift it by the cable! 3 Do a thorough visual inspection of the transducer. Check for dents, scratches, holes or other damage to the surface. 102 467020/B Installing the hull unit Note It is very important that neither this coating nor the internal parts of the transducer are damaged during the handling, installation or cleaning. Any holes and/or scratches in the transducer surface will allow water to penetrate the transducer. If a leak occurs, the transducer must be replaced. If you find suspicious damage, take high resolution photos that show the damage. Contact your dealer or the Kongsberg Maritime support organization for advice. 4 Place the transducer back in its transport box for protection. Keep the transducer in place in the box until you need to mount it. Related topics Installation procedures, page 100 Installing the hull unit, page 88 Cutting the transducer shaft The hull unit can be placed on new or existing installation trunks with different heights. The height of the installation trunk and the length of the transducer shaft can be adjusted to fit the size of the vessel. The transducer shaft is supplied with fixed lengths. You may need to reduce the length of the transducer shaft. Prerequisites The shipyard must provide all necessary tools and manpower. The following specific tools and consumables are required: • Lathe (Recommended) • Grinder • Metal-cutting saw (Optional) • Angle grinder (Optional) • Surface grinder Context You may need to reduce the length of the transducer shaft. The length depends on the height of your installation trunk and the lowering depth of the transducer. Use the following equation to calculate the length (in millimetres): [Required length of transducer shaft] = [Height of installation trunk] + 400 467020/B 103 Simrad SY50 Installation Manual A This area is allocated for the O-ring. B Shape the top of the transducer shaft with an angle. Do not allow the sloping edge to extend beyond 4.5 mm. C Do not damage the surface of the transducer shaft. Note Do not damage the surface of the transducer shaft. Any dents or scratches in this surface may result in a water leak through the gaskets in the mounting flange. Do not damage the threads on the end of the transducer shaft to which the transducer flange will be attached. Tip Copy the shape and the surface quality from the top of the original shaft. Procedure 1 Calculate the required length of the shaft. The length depends on the height of your installation trunk and the lowering depth of the transducer. 2 Cut the transducer shaft to the correct length. Shape the top of the transducer shaft with an angle. Do not allow the sloping edge to extend beyond 4.5 mm. See the illustration. 3 Finalize the cut by grinding it. The surface grinding must protect the O-ring from damage. The surface of the transducer shaft and the cut must be so smooth that it can be easily pushed through the transducer shaft sleeve without causing damage. Sharp edges must be avoided! Surface specification: • Roughness Average (Ra) = 1.6 • Maximum Roughness Depth (Rmax) = 10 Related topics Installation procedures, page 100 Installing the hull unit, page 88 Length of transducer shaft versus height of installation trunk, page 95 104 467020/B Installing the hull unit Making recesses for the set screws used to mount the cable gland assembly A cable gland assembly is placed on the top of the transducer shaft. The purpose of the cable gland is to protect the transducer cable and to secure the watertight integrity of the vessel. The cable gland is mounted with three set screws. Prerequisites The shipyard must provide all necessary tools and manpower. The following specific tools and consumables are required: • Permanent marker pen Context A Cable gland (assembly) B Use a permanent marker through the holes in the bushing to mark the drilling points for the set screws. C Transducer shaft D Make a 2 mm deep recess for each set screw. Make sure that the surface around the recess hole is smooth. E Do not damage the surface of the transducer shaft. Note Do not damage the surface of the transducer shaft. Any dents or scratches in this surface may result in a water leak through the gaskets in the mounting flange. Do not damage the threads on the end of the transducer shaft to which the transducer flange will be attached. Procedure 1 Place the bushing firmly onto the top of the transducer shaft. 2 Use a permanent marker through the holes in the bushing to mark the drilling points for the set screws. 3 Remove the bushing. 467020/B 105 Simrad SY50 Installation Manual 4 Make a 2 mm deep recess for each set screw. See the illustration. Note Do not damage the surface of the transducer shaft. Make sure that the surface around the recess hole is smooth. You will later push the transducer shaft through the gaskets inside the mounting flange. These gaskets must not be damaged. Do not mount the cable gland assembly. This is done later in the installation process. Related topics Installation procedures, page 100 Installing the hull unit, page 88 Mounting the transducer flange The transducer flange is mounted to the threaded end of the transducer shaft. Prerequisites The shipyard must provide all necessary tools and manpower. The following specific tools and consumables are required: • Loctite 263, 270 or 271 (medium-high strength threadlocker) • Silicone greaseWe recommend the following lubricant: Parker Super O-Lube – Manufacturer: Parker – Manufacturer’s website: http://www.parker.com – Kongsberg Maritime part number: 654-077261 • Permanent marker pen • Line laser (Optional) Do not apply any type of grease or lubricant to the threads at the bottom of the transducer shaft. Context Do not damage the surface of the transducer shaft. Any dents or scratches in this surface may result in a water leak through the gaskets in the mounting flange. 106 467020/B Installing the hull unit A Use this hole in the transducer flange to release the transducer for replacement. B Set screws (3) C O-ring (32 mm) (Part number: 443318) D Do not damage the surface of the transducer shaft. E Transducer flange F Forward mark G Guide pin (By means of the guide pins the transducer will only fit in one direction.) Note Do not apply any type of grease or lubricant to the threads at the bottom of the transducer shaft. Procedure 1 Install the O-ring. Use the O-ring with the following diameter: 32 mm. 2 a Clean the O-ring groove and inspect the O-ring. b Apply a thin film of silicon grease on the O-ring. c Place the O-ring in its groove in the transducer flange. See the illustration. Hold the transducer shaft firmly in place. If you use a mechanical device to hold the transducer shaft, make sure that the surface of the shaft is not damaged. Use relevant protection to prevent damage! The best place to hold the shaft is from the end of the threads at the transducer end, and up to 150 mm. 467020/B 107 Simrad SY50 Installation Manual 3 Screw the transducer flange carefully onto the end of the transducer shaft. Note Pay close attention to avoid damage to the threads. Do not apply any type of grease or lubricant to the threads at the bottom of the transducer shaft. 4 Apply Loctite to each set screw. 5 Insert the set screws. Tighten the screws firmly. 6 Place the forward mark on the top of the transducer shaft. a Locate the forward mark on the transducer flange. b Use a line laser or a piece of string to transport the forward mark to the top of the transducer shaft. c Chop the forward mark into the steel on the flat top of the transducer shaft. d Use a permanent marker to transport the forward mark down from the top of the transducer shaft and onto its side. Place the forward mark between 25 and 40 mm from the top of the transducer shaft. e Make sure that the forward mark is visible when the cable gland assembly is mounted. Related topics Installation procedures, page 100 Installing the hull unit, page 88 Mounting the trunk bearing The trunk bearing is threaded onto the transducer shaft. Prerequisites The shipyard must provide all necessary tools and manpower. The following specific tools and consumables are required for this task: • Allen key • Spanner (Wrench) • Torque wrench • Grease Context The trunk bearing serves important purposes: 108 467020/B Installing the hull unit • It places the transducer shaft as close to the centre of the installation trunk as possible to prevent the transducer from touching the trunk wall. • It provides support for the transducer shaft when the vessel is moving. • It removes marine growth (biological fouling) from the trunk walls. A Mounting bolts B Bearing blocks C Guide pin (By means of the guide pins the transducer will only fit in one direction.) D Secure the trunk bearing to the shaft with the two bolts inside the bearing. E Turn the direction of the trunk bearing so that one of the bearing blocks is aligned to the forward mark on the transducer flange. This is important to prevent physical vibrations. F Transducer lowered to 400 millimetres: 50 mmTransducer lowered to 600 millimetres: 250 mm G Set screw The trunk bearing moves up and down inside the installation trunk when the transducer is lowered and hoisted. It is important to adjust the gap between the bearing blocks and the trunk wall to reduce the friction. At the same time, the gap must not permit any vibrations when the transducer is lowered and the vessel is moving. Note Do not damage the surface of the transducer shaft. Any dents or scratches in this surface may result in a water leak through the gaskets in the mounting flange. Be careful not to damage the transducer flange when you move the transducer shaft inside the trunk. 467020/B 109 Simrad SY50 Installation Manual Procedure 1 Mount the trunk bearing onto the transducer shaft. To place the trunk bearing at the correct height on the transducer shaft, measure the distance from the top of the transducer flange to the bottom of the trunk bearing. See the illustration: (F) • Transducer lowered to 400 millimetres: 50 mm • Transducer lowered to 600 millimetres: 250 mm 2 Turn the direction of the trunk bearing so that one of the bearing blocks is aligned to the forward mark on the transducer flange. This is important to prevent physical vibrations. You must align one of the bearing blocks to the forward mark on the transducer flange. Later, when you fasten the transducer shaft to the gantry, rotate the shaft so that the both the forward mark and the bearing block point directly forward. 3 Secure the trunk bearing to the shaft with the two bolts inside the bearing. See the illustration: (D) 4 Apply a suitable amount of grease to the bolts. 5 Tighten the bolts on the bearing blocks temporarily to allow the transducer shaft to be centred in the installation trunk. 6 Move the transducer shaft carefully up and down inside the installation trunk. a Make sure that the gap between the bearing blocks and the inside wall of the installation trunk is less than 0.5 mm. It is important to adjust the gap between the bearing blocks and the trunk wall to reduce the friction. At the same time, the gap must not permit any vibrations when the transducer is lowered and the vessel is moving. 7 b Make sure that the transducer shaft is placed as close to the centre of the installation trunk as possible. c Make sure that the transducer flange does not touch the installation trunk walls when you move transducer shaft. d Adjust as required. Tighten the bolts when you are satisfied. See the illustration: (A) When you tighten the bolts, do this evenly to get the same gap on each side of the transducer shaft. 110 467020/B Installing the hull unit Use the following torque: 44 Nm Related topics Installation procedures, page 100 Installing the hull unit, page 88 Mounting the gantry The gantry is placed on top of the mounting flange. Prerequisites The shipyard must provide all necessary tools and manpower. The following specific tools and consumables are required: • Allen key • Grease Context The gantry is delivered as a completed assembly. The gantry is mounted using two brackets welded to the mounting flange. A mounting pin passes through the holes at the bottom of the gantry and the two mounting brackets. Once inserted, each end of the mounting pin is secured using a safety clip. Note Do not damage the surface of the transducer shaft. Any dents or scratches in this surface may result in a water leak through the gaskets in the mounting flange. 467020/B 111 Simrad SY50 Installation Manual A Mounting brackets for gantry B Mounting pin C Lifting clamp D Push the transducer shaft carefully up through the mounting flange and the transducer shaft sleeve. E Air vent plug (We recommend that you rotate the mounting flange and transducer shaft sleeve so that the air vent plug points forward.) Procedure 1 Observe the bolt holes on the top of the installation trunk to decide which hole on the mounting flange that shall point forward. We recommend that you rotate the mounting flange and transducer shaft sleeve so that the air vent plug points forward. The properties of the sonar room may prevent you from rotating the mounting flange to the recommended angle. Do not rotate the mounting flange so that the hoisting motor and gantry is placed in parallel to or across the longitudinal direction of the vessel. Any rotation angles - except those specified - are accepted if it is necessary to obtain ample space for installation, maintenance and replacement of parts. Note Do not place the hull unit with the hoisting motor facing aft or forward. Do not place the hull unit with the hoisting motor facing port or starboard. For more information, see: Rotating the mounting flange on the installation trunk, page 97 2 112 Mount the gantry. 467020/B Installing the hull unit a Apply a suitable amount of grease to the bolt. b Under the location of the gantry, through the mounting flange, insert the bolt for the installation trunk. You will not be able to insert this bolt once the gantry has been mounted. c Remove the mounting pin from the bottom of the gantry. See the illustration. d Place the gantry on top of the two brackets on the mounting flange. e Align the holes and push the mounting pin through. f Secure each end of the mounting pin with the washers and the safety clips. Note The gantry is not properly supported until you fasten the lifting clamp to the transducer shaft. 3 Add a thin layer of grease to the top of the transducer shaft. 4 Push the transducer shaft carefully up through the mounting flange and the transducer shaft sleeve. 5 Remove all grease from the top of the transducer shaft. 6 Rotate the transducer shaft so that the forward mark on the top of the shaft is aligned with the forward hole in the mounting flange. 7 Attach the lifting clamp firmly to the top of the transducer shaft. The distance from the top of the transducer shaft and down to the top of the lifting clamp may need to be adjusted later. A good starting distance is: 40 mm 8 Apply a thin layer of grease, then tighten the bolt on the lifting clamp. Note This is a critical step. The lifting clamp supports the total weight of the transducer shaft, trunk bearing and transducer. Inaccurate mounting of the lifting clamp can cause the transducer shaft to loosen. This can cause damage to the sonar system, and even to the vessel if the transducer shaft and transducer are lost. Make sure to use the wedge lock washers. Use the following torque: 75 Nm Note Make sure to use the wedge lock washers. A wedge lock washer (also known as a Nord-lock washer) is a two-piece washer with radial teeth on one side and wedging action of the halves where they join. These washers provide the highest amount of vibrational loosening prevention. 467020/B 113 Simrad SY50 Installation Manual Related topics Installation procedures, page 100 Installing the hull unit, page 88 Mounting the transducer The transducer is mounted under the transducer flange at the bottom of the transducer shaft. Prerequisites The shipyard must provide all necessary tools and manpower. The following specific tools and consumables are required: • Loctite 263, 270 or 271 (medium-high strength threadlocker) • Allen key • Silicone grease We recommend the following lubricant: Parker Super O-Lube – Manufacturer: Parker – Manufacturer’s website: http://www.parker.com – Kongsberg Maritime part number: 654-077261 Illustration: A Mounting bolts (8 mm) B Transducer cable C O-ring (90 mm) D Guide holes (By means of the guide pins the transducer will only fit in one direction.) Context A transducer must always be handled as a delicate instrument. A physical blow to the transducer face may easily damage one or more elements. Do not damage the surface of the transducer shaft. Any dents or scratches in this surface may result in a water leak through the gaskets in the mounting flange. Note The transducer body is fitted with self-locking threads. The internal thread provides a self-locking connection, which can be used repeatedly. For this reason it is not necessary to use any type of washers to secure the assembly. 114 467020/B Installing the hull unit Procedure 1 Install the O-ring. Use the O-ring with the following diameter: 90 mm. a Clean the O-ring groove and inspect the O-ring. b Apply a thin film of silicon grease on the O-ring. c Place the O-ring in its groove at the top of the transducer. See the illustration. 2 Pull the transducer cable up through the transducer shaft. 3 Apply Loctite to each mounting bolt. 4 Mount the transducer using the bolts provided. Observe the guide pins! By means of the guide pins the transducer will only fit in one direction. Tighten the bolt firmly. Use the following torque: 10 Nm The transducer body is fitted with self-locking threads. The internal thread provides a self-locking connection, which can be used repeatedly. For this reason it is not necessary to use any type of washers to secure the assembly. 5 Pull the transducer cable through the bushing, the washers, the rubber gasket and the packing nipple. See the illustration: 6 A O-ring (44.2 mm) (Part number: 540–096105) B Packing nipple C Washers (2) D Rubber gasket E Bushing F Set screws (3) G Transducer shaft Assemble the cable gland. Related topics Installation procedures, page 100 Installing the hull unit, page 88 467020/B 115 Simrad SY50 Installation Manual Mounting the hull unit on top of the installation trunk The upper parts of the hull unit include the mechanical gantry, the hoisting motor, the hoisting spindle and the junction box. The transducer cable is placed inside the transducer shaft. The transducer shaft is supported by the gantry, and penetrates the transducer shaft sleeve and the mounting flange. The transducer is mounted to the bottom of the transducer shaft. The complete assembly is mounted on the top of the installation trunk. Prerequisites The vessel is in dry dock. The shipyard must provide all necessary tools and manpower. The following specific tools and consumables are required: • Torque wrench • A crane (or other lifting device) capable of lifting the entire hull unitThe lifting device must be rated to minimum twice the weight of the hull unit. • Grease Context A dedicated gasket is provided with the delivery. This gasket ensures a watertight connection between the installation trunk and the bottom of the transducer shaft sleeve. During the installation process, make sure that the gasket is kept safe from damage, and that the top of the installation trunk is kept clean, smooth and without physical damage such as scratches or dents. Procedure 1 Lift the hull unit and place it vertically over the installation trunk. Make sure that you do not damage the delicate parts of the hull unit. Note Make sure that you do not damage the transducer or the cable. Watch the hull unit carefully during the lift to prevent the delicate parts from being damaged, stuck or hooked on to protruding objects. 2 If applicable: Remove the blind flange from the top of the installation trunk. Store the blind flange in the sonar room for possible future use. 3 4 116 Check the top of the installation trunk. a Make sure that the surface of the installation trunk is clean and free from grit or other damaging particles. b Make sure that the top of the installation trunk has not been damaged, and that it is smooth and even without physical scratches or dents. Rubber gasket: a Make sure that the gasket is undamaged without cracks or signs of wear. b Make sure that the gasket is NOT covered with grease or lubricants. 467020/B Installing the hull unit c Place the gasket at its correct location. Note If you suspect that the gasket is damaged, replace it. If the gasket has been contaminated with dirt, grease or lubricants, it must be replaced. 5 Lower the hull unit carefully onto the installation trunk. 6 Align the mounting holes carefully. 7 Make sure that the mounting flange is positioned so that the hole you have previously defined as "forward" is in fact facing forward. We recommend that you rotate the mounting flange and transducer shaft sleeve so that the air vent plug points forward. Do not rotate the mounting flange so that the hoisting motor and gantry is placed in parallel to or across the longitudinal direction of the vessel. The properties of the sonar room may prevent you from rotating the mounting flange to the recommended angle. Any rotation angles - except those specified - are accepted if it is necessary to obtain ample space for installation, maintenance and replacement of parts. Note Do not place the hull unit with the hoisting motor facing aft or forward. Do not place the hull unit with the hoisting motor facing port or starboard. For more information, see: Rotating the mounting flange on the installation trunk, page 97 8 Apply a suitable amount of grease to the bolts. 9 Tighten the bolts temporarily. Related topics Installation procedures, page 100 Installing the hull unit, page 88 Lubricating the transducer shaft sleeve The transducer shaft sleeve is a vital part of the hull unit. It supports the transducer shaft, and allows the shaft to move down and up to lower and hoist the transducer. The transducer shaft sleeve is filled with grease. The grease ensures that the vertical movement of the transducer shaft is not limited by friction. The grease also ensures that the entire construction is waterproof. Prerequisites The shipyard must provide all necessary tools and manpower. The following specific tools and consumables are required: 467020/B 117 Simrad SY50 Installation Manual • Torque wrench • GreaseUse an industrial grease designed for heavy-duty applications. The grease must provide efficient protection against rust and corrosion, and resist water washout. We recommend the following lubricant: Mobil Mobilux EP 2 – Manufacturer: Mobil – Manufacturer’s website: https://www.mobil.com – Kongsberg Maritime part number: 654-079835 • Permanent marker pen • Line laser (Optional) Procedure 1 Open the pressure relief plug. You do not need to remove the pressure relief plug completely. It has a groove that allows excess lubricant to drain out. 2 Connect a grease gun to the nipple and add grease. 3 Stop applying lubrication when excess grease leaks out of the pressure relief plug. 4 Close the pressure release plug firmly. 118 467020/B Installing the hull unit A Remove the protective cap on the top cover. Use a spanner to rotate the hoisting spindle. B Forward mark (Example) C Forward (Bow) 5 Make sure that the transducer can be lowered and hoisted without excessive friction. 6 a Remove the protective cap on the top cover. b Use a spanner to rotate the hoisting spindle.. c Lower and hoist the transducer manually approximately 20 to 30 millimetres. Mount and tighten the relevant nuts and bolts. First, tighten all the nuts to finger tight. Then work alternately on opposite sides of the construction. Use the following torque: 140 Nm 7 Place the forward mark on the mounting flange. a Use a line laser or a piece of string to transport the forward from the top of the transducer shaft and down onto the mounting flange. b Chop the forward mark into the steel, for example as a circular “O”. c Use a permanent red marker or paint to clearly identify the forward mark. Related topics Installation procedures, page 100 Installing the hull unit, page 88 Inspecting the transducer While the vessel is still in dry dock, the transducer surface must be inspected for potential damage that may have been inflicted during the installation. Prerequisites Neither tools nor instruments are required. If you find damage, you need a high resolution camera to document it. 467020/B 119 Simrad SY50 Installation Manual Context The transducer is covered with a thick red or black protective coating made of a special plastic type. The protective coating is a vital part of the transducer. It is very important that neither this coating nor the internal parts of the transducer are damaged during the handling, installation or cleaning. Any holes and/or scratches in the transducer surface will allow water to penetrate the transducer. If a leak occurs, the transducer must be replaced. Procedure 1 Lower the transducer manually. a Remove the protective cap on the top cover. b Use the spanner to rotate the hoisting spindle. c Lower the transducer to its bottom position. Note Locate the Lower Limit Switch. It is placed inside the bottom of the gantry. Stop the rotation when the switch is activated. d 2 Replace the protective cap cover. Do a thorough visual inspection of the transducer. Check for dents, scratches, holes or other damage to the surface. Note It is very important that neither this coating nor the internal parts of the transducer are damaged during the handling, installation or cleaning. Any holes and/or scratches in the transducer surface will allow water to penetrate the transducer. If a leak occurs, the transducer must be replaced. If you find suspicious damage, take high resolution photos that show the damage. Contact your dealer or the Kongsberg Maritime support organization for advice. 3 Hoist the transducer manually. a Remove the protective cap on the top cover. b Use the spanner to rotate the hoisting spindle. c Hoist the transducer to its upper position. Note Locate the Upper Limit Switch. It is placed inside the top of the gantry. Stop the rotation when the switch is activated. d 120 Replace the protective cap cover. 467020/B Installing the hull unit 4 Make sure that the bottom of the transducer is positioned 10 to 20 mm above the bottom of the installation trunk. 5 If necessary, adjust the height. a Hold the transducer shaft firmly in place to prevent it from falling down. b Loosen the bolt on the lifting clamp. c Adjust the vertical position of the transducer shaft. d Make sure that the bottom of the transducer is positioned 10 to 20 mm above the bottom of the installation trunk. e Apply a thin layer of grease, then tighten the bolt on the lifting clamp. Note This is a critical step. The lifting clamp supports the total weight of the transducer shaft, trunk bearing and transducer. Inaccurate mounting of the lifting clamp can cause the transducer shaft to loosen. This can cause damage to the sonar system, and even to the vessel if the transducer shaft and transducer are lost. Make sure to use the wedge lock washers. Use the following torque: 75 Nm Note Make sure to use the wedge lock washers. A wedge lock washer (also known as a Nord-lock washer) is a two-piece washer with radial teeth on one side and wedging action of the halves where they join. These washers provide the highest amount of vibrational loosening prevention. Apply Loctite to secure the bolt. Result Requirements Results The transducer is clean and free from scratches, dents or other physical damage. Date and signature: Related topics Installation procedures, page 100 Installing the hull unit, page 88 467020/B 121 Simrad SY50 Installation Manual Verifying the quality of the hull unit installation A quality inspection must take place after the hull unit has been installed, and while the vessel is still in dry dock. The inspection shall verify that the sonar room meets the requirements, and that the hull unit has been installed correctly. Prerequisites The vessel is in dry dock. Procedure 1 Make sure that the sonar room requirements are met. 2 Make sure that the unit is not physically damaged, and that the surfaces and paint-work are clean without dents or scratches. The physical handling during the installation may have caused some minor scratches to the surfaces or paint-work. This can be accepted. However, if rough handling has caused serious damage, this must be recorded with a written statement and necessary photos, so that corrective actions can be made. 3 4 Make sure that the physical installation of the unit has been completed. a Make sure that the compartment ("sonar room") in which the hull unit is mounted is clean and dry. b Make sure that ample space is provided around the unit to allow for maintenance and replacement of parts. Make sure that cable installation has been completed. a Lower and hoist the transducer two or three times to make sure that the operation is smooth, and that the transducer cable can move freely. b Make sure that all cables leading to and from the unit have been properly mounted and secured. c Make sure that enough slack has been provided on each cable to allow for maintenance and replacement. d When the transducer is hoisted to its upper position, make sure that the bottom of the transducer is positioned minimum 10 mm inside the installation trunk. e When the transducer is lowered to its bottom position, make sure that no parts of the trunk bearing are located outside the installation trunk. 5 Make sure that all relevant parts have been painted with the correct preservation medium to prevent corrosion. 6 Make sure that all relevant actions have been taken to reduce flow noise. 122 467020/B Installing the hull unit a The hull plating in front of the transducer must be as smooth as possible. Important Be especially aware of bilge keels and sacrificial anodes. The keel must be rounded off without sharp edges. Neither extruding objects nor abrupt transitions must be present. Fill the space around any mounting bolts, as well as dents and cracks in the plating, with a a suitable filling compound (putty). b 7 The fairing around the installation trunk must be streamlined. Fill in the result table. Result Requirements Results The compartment in which the hull unit is installed ("sonar room") is clean and dry. The sonar room meets all requirements related to the vessel’s watertight integrity. The sonar room meets all size and access requirements. The access hatches are suitably constructed and located. The sonar room meets all requirements related to insulation, heating and ventilation. The sonar room meets all requirements related to electrical installations, including light, power, communication and cabling. A bilge pump is installed. The sonar room is suitably decked. The hull unit is correctly installed with easy access for maintenance and replacement of parts. All cables are properly mounted with enough slack. The transducer cable can move freely when the transducer is lowered and hoisted. When the transducer is hoisted to its upper position, the bottom of the transducer is positioned minimum 10 mm inside the installation trunk. When the transducer is lowered to its bottom position, no parts of the trunk bearing are visible outside the installation trunk. All relevant parts have been painted with the correct preservation medium to prevent corrosion. There are no corrosive attacks. All relevant actions have been taken to reduce flow noise. Further requirements If the inspection reveals errors, inaccuracies or unfortunate dispositions related to units, devices or cables, use the Installation remarks form to document these. If necessary, write a full report, and attach high resolution photos. 467020/B 123 Simrad SY50 Installation Manual Related topics Installation procedures, page 100 Installing the hull unit, page 88 Hull unit and transducer alignment The alignment of the hull unit and transducer is done in the SY50 user interface. This is described in the Setting to work chapter. Related topics Installing the hull unit, page 88 124 467020/B Cable layout and interconnections Cable layout and interconnections Topics Read this first, page 126 Cable plans, page 127 Installing the SY50 cables, page 135 Cable drawings and specifications, page 144 467020/B 125 Simrad SY50 Installation Manual Read this first Detailed information about cable specifications, termination and connectors is provided. Unless otherwise specified, all cables are supplied by Kongsberg Maritime as a part of the delivery. Detailed information about relevant cable specifications, termination and connectors is provided. Each drawing provides additional information, and may, when applicable, include minimum specifications, connector terminations and the required number of cores. Drawings are generally not provided for standard commercial cables. Cables fall into three categories. 1 System cables: System cables are provided by Kongsberg Maritime as a part of the delivery. 2 Shipyard cables: Shipyard cables must be provided by the shipyard doing the installation, or the shipowner. The cables must meet the minimum specifications provided in this publication. 3 Commercial cables: Commercial cables may be provided by Kongsberg Maritime as a part of the delivery. The cables may also be included with third party items that are used with the SY50 system. All electronic installations and corresponding wiring must be in accordance with the vessel's national registry and corresponding maritime authority and/or classification society. Note It is very important that all cables are properly installed and correctly terminated. Observe the relevant regulations and work standards. Always leave enough cable slack close to system units and cabinets to allow for maintenance. Only skilled and authorized personnel can install the SY50 cables. Kongsberg Maritime accepts no responsibility for damage to the system, or reduced operational performance, when this is caused by improper wiring. Before you install or maintain the system cables, make sure that the AC mains circuit breaker for the system is disconnected. Related topics Cable layout and interconnections, page 125 126 467020/B Cable layout and interconnections Cable plans Topics Topside cable plan, page 128 List of topside cables, page 129 Sonar room cable plan, page 130 List of sonar room cables, page 131 Comments, page 132 Options, page 134 467020/B 127 Simrad SY50 Installation Manual Topside cable plan The topside/bridge cables include those used to connect the Processor Unit and the display to each other, as well as cables for AC mains power and external devices. The connection between the Processor Unit and the operating panel is also shown. One high capacity Ethernet cable connects the Processor Unit to the Power Supply Unit. A Display B Processor Unit C Operating Panel D Uninterruptible power supply (UPS) Cables identified with an asterisk (*) are system or commercial cables. These cables are provided in the delivery or with the relevant item. Cable numbers that are not used are spares for optional equipment and/or future expansions. For more information about the cables, see: Comments, page 132 Related topics Cable plans, page 127 Cable layout and interconnections, page 125 128 467020/B Cable layout and interconnections List of topside cables Each topside cable used by the SY50 system is listed. Cable Type From To Minimum requirements C1 AC Power cable Uninterruptible power supply (UPS) Vessel AC power 2 x 1.5 mm2 + 1.5 mm2 Ground C2 AC Power cable Display Uninterruptible power supply (UPS) 2 x 1.5 mm2 + 1.5 mm2 Ground C3 AC Power cable Processor Unit Uninterruptible power supply (UPS) 2 x 1.5 mm2 + 1.5 mm2 Ground C6 Ground cable Processor Unit Vessel ground 1 x 6 mm2 C8 Ethernet cable Processor Unit Power Supply Unit CAT5-E STP (Shielded Twisted Pair) C9 Video cable Processor Unit Display C12 USB cable Processor Unit Operating Panel C13 Serial cable Processor Unit External device(s) 2 x 4 x 0.5 mm2 C14 Ethernet cable Processor Unit Local Area Network (LAN) CAT5-E STP (Shielded Twisted Pair) Cable numbers that are not used are spares for optional equipment and/or future expansions. For more information about the cables, see: Comments, page 132 Related topics Cable plans, page 127 Cable layout and interconnections, page 125 467020/B 129 Simrad SY50 Installation Manual Sonar room cable plan The sonar room cables include those used to connect the SY50 units to AC mains power, as well as the control cables between the units. One high capacity Ethernet cable connects the Processor Unit to the Power Supply Unit. A Power Supply Unit B Hoisting motor C Junction box D Cable gland E Transducer F Uninterruptible power supply (UPS) Cables identified with an asterisk (*) are system or commercial cables. These cables are provided in the delivery or with the relevant item. Cable numbers that are not used are spares for optional equipment and/or future expansions. For more information about the cables, see: Comments, page 132 Related topics Cable plans, page 127 Cable layout and interconnections, page 125 130 467020/B Cable layout and interconnections List of sonar room cables Each cable used by the SY50 system in the sonar room is listed. Cable Type From To Minimum requirements C8 Ethernet cable Processor Unit Power Supply Unit CAT5-E STP (Shielded Twisted Pair) C20 Ground cable Power Supply Unit Vessel ground 1 x 6 mm2 C22 AC Power cable Power Supply Unit Uninterruptible power supply (UPS) 2 x 1.5 mm2 + 1.5 mm2 Ground C23 AC Power cable Uninterruptible power supply (UPS) Vessel AC power 2 x 1.5 mm2 + 1.5 mm2 Ground C24 Control cable Power Supply Unit Junction box C25 Transducer cable Power Supply Unit Transducer Cable numbers that are not used are spares for optional equipment and/or future expansions. For more information about the cables, see: Comments, page 132 Related topics Cable plans, page 127 Cable layout and interconnections, page 125 467020/B 131 Simrad SY50 Installation Manual Comments Some of the cables used by the SY50 system require additional explanations and recommendations. Cable numbers Cable numbers that are not used are spares for optional equipment and/or future expansions. Project cables The SY50 system is often a part of a project delivery. For such deliveries, specific project cable drawings are established to show all the main cables, and how the various products are connected. In such project cable drawings, the SY50 system cables may be identified as SY50/Cx. C22 AC Power cable This cable must be provided by the installation shipyard. C1, C2, C3, C23 AC Power cables Standard commercial AC mains cables are used. Each cable is supplied with the relevant unit. The typical cable length is between 1,5 and 2 meters. If this is too short you must use an extension cable (not recommended), mount a new power outlet within range, or make your own power cable with sufficient length. C8 Ethernet cable The maximum length of the Ethernet cable from the Processor Unit to the Power Supply Unit is 100 meters. It is very important that high-quality Ethernet cables are used. You must use CAT-5E STP (Shielded Twisted Pair) quality or better. Using cables with lower bandwidth capacity will reduce performance. Do not make the connection using the existing local area network (LAN). We strongly recommend that you install minimum two Ethernet cables between the sonar room and the bridge. One cable is for operational use, while the other is spare. C9 Video cable This is a commercial cable. The display cable is often physically attached to the display, and terminated in the “computer end” with a male connector. If the cable is not attached, it is normally provided with the display. Keep the display cable as short as possible. If the cable is too long, it may pick up electric noise, and this will reduce the image quality. The graphic adapter on the Processor Unit provides several display connectors. You can use one or two displays on your Processor Unit depending on personal and/or operational preferences. With more than one display connected, use the operating system functionality to control the presentations. C12 USB cable This is a commercial cable. 132 467020/B Cable layout and interconnections C13 Serial cable If you wish to use RS-422 or RS-485 serial communication, use a cable with twisted pairs. More than one serial line cable may be required to connect the computer to external devices. To identify these cables, use postfix letters. (C13A, C13B, C13C...). C24 Control cable This cable is included in the delivery. It comes pre-connected to the Power Supply Unit. Length: 6 metres C25 Transducer cable The transducer cable is provided with the transducer. Related topics Cable plans, page 127 Cable layout and interconnections, page 125 467020/B 133 Simrad SY50 Installation Manual Options Some optional equipment available for the SY50 system will affect the cable layout. Operating Panel Mk2 The SY50 system supports two different operating panels. These are referred to as "Mk2" and "Mk3". The Mk3 Operating Panel is the standard panel provided for the SY50 system. It is connected to the Processor Unit with a USB cable. A power cable is not required. A Mk2 Operating Panel can be supplied to replace the standard panel. A dedicated Ethernet cable is used to connect the Operating Panel to the Processor Unit. The Operating Panel is provided with a built-in power supply. The mains voltage for the Operating Panel is 115 or 230 VAC, and it will automatically sense the supply voltage. These changes must be made to the cabling: Cable Type From To Minimum requirements C5 AC Power cable Operating Panel Uninterruptible power supply (UPS) 2 x 1.5 mm2 + 1.5 mm2 Ground C12 Ethernet cable Operating Panel Processor Unit CAT5-E STP (Shielded Twisted Pair) Hull unit for 24 VDC operation A hull unit for 24 VDC operation can be supplied. The uninterruptible power supply (UPS) in the sonar room is then not required. These changes must be made to the cabling: Cable Type From To C22 DC Power cable Power Supply Unit Vessel DC power C23 Not used Minimum requirements Related topics Cable plans, page 127 Cable layout and interconnections, page 125 134 467020/B Cable layout and interconnections Installing the SY50 cables Topics Prerequisites for cable installation, page 136 Installing the topside cables, page 136 Installing the sonar room cables, page 138 Processor Unit front panel description: Nexcom NISE 3900E, page 139 Processor Unit rear panel description: Nexcom NISE 3900E, page 140 Operating Panel connectors (Mk2), page 143 Operating Panel connectors (Mk3), page 143 467020/B 135 Simrad SY50 Installation Manual Prerequisites for cable installation Correct wiring is crucial for the operational performance of the SY50 system. Electrical connections can only be made by skilled personnel (ship electricians, technicians or engineers). The installation shipyard must prepare detailed drawings of the electrical system, and identify each cable. Observe the basic cable requirements. You must be equipped with a standard set of tools. This tool set must comprise the normal tools for cable installation tasks. This includes different screwdriver types, pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in various sizes. We recommend that all tools are demagnetized to protect your equipment. Depending on the tasks at hand, additional tools may be required. Refer to the cable plans and the list of cables. Detailed information about cable specifications, termination and connectors are provided in the relevant cable drawings. Unless otherwise specified, all cables are supplied with the SY50 delivery. In order to ease the access for maintenance purposes, and to allow for vibration, make sure that some slack is provided for each cable. Note All electronic installations and corresponding wiring must be in accordance with the vessel's national registry and corresponding maritime authority and/or classification society. Only skilled and authorized personnel can install the SY50 cables. Kongsberg Maritime will not accept any responsibility for errors, malfunctions or damage to system or personnel caused by improper wiring. Related topics Cable layout and interconnections, page 125 Installing the SY50 cables, page 135 Installing the topside cables The sonar room cables include those used to connect the SY50 units to AC mains power, as well as the control cables between the units. One high capacity Ethernet cable connects the Processor Unit to the Power Supply Unit. Procedure 1 Prepare the power cables, but do not connect any units to AC mains power. Cable From To C1 Uninterruptible power supply (UPS) Vessel AC power C2 Display Uninterruptible power supply (UPS) C3 Processor Unit Uninterruptible power supply (UPS) For more information about the cables, see: Comments, page 132 136 467020/B Cable layout and interconnections Cable details: AC power cable using IEC C13 inline socket, page 148 2 Connect the ground cables. Cable From To C3 Processor Unit Vessel ground Cable details: Ground cable, page 150 3 Connect the display cable(s). Cable From To C9 Processor Unit Display For more information about the cables, see: Comments, page 132 4 5 Connect the USB cable to the Operating Panel. Cable From To C12 Processor Unit Operating Panel Connect the Ethernet cable from the Processor Unit to the Power Supply Unit. Cable From To C8 Processor Unit Power Supply Unit For more information about the cable, see: Comments, page 132 Cable details: RJ45 High speed Ethernet cable (1000Base-t), page 154 6 Connect the serial cables to the relevant external devices. Cable From To C13 Processor Unit External device(s) For more information about the cables, see: Comments, page 132 Cable details: RS-232 serial line connection using three wires, page 151 RS-232 serial line connection using five wires, page 152 RS-232 used as synchronization trigger (input or output), page 153 About serial lines, page 159 7 (Optional) Connect the signal cable from the Processor Unit to the synchronization system. Cable From To C13 Processor Unit Synchronization system Cable details: K-Sync interface to generic RS-232 synchronization input, page 155 Simrad TU40 interface to generic RS-232 synchronization input, page 157 467020/B 137 Simrad SY50 Installation Manual Related topics Cable layout and interconnections, page 125 Installing the SY50 cables, page 135 Installing the sonar room cables The sonar room cables include those used to connect the SY50 units to AC mains power, as well as the control cables between the units. One high capacity Ethernet cable connects the Processor Unit to the Power Supply Unit. Procedure 1 Prepare the power cables, but do not connect any units to AC mains power. Cable From To C22 Power Supply Unit Uninterruptible power supply (UPS) C23 Uninterruptible power supply (UPS) Vessel AC power For more information about the cables, see: Comments, page 132 Cable details: C22 AC Power cable, page 145 AC power cable using IEC C13 inline socket, page 148 2 Connect the ground cables. Cable From To C20 Power Supply Unit Vessel ground Cable details: Ground cable, page 150 3 Connect the control cable. Cable From To C24 Power Supply Unit Junction box For more information about the cable, see: Comments, page 132 Cable details: C24 Control cable, page 146 4 Connect the transducer cable. Cable From To C25 Transducer Power Supply Unit For more information about the cable, see: Comments, page 132 Cable details: C25 Transducer cable, page 147 Related topics Cable layout and interconnections, page 125 Installing the SY50 cables, page 135 138 467020/B Cable layout and interconnections Processor Unit front panel description: Nexcom NISE 3900E The front panel of the Processor Unit holds interface ports, LED indicators and an on/off switch. A USB 2.0 ports B Graphic adapter (DisplayPort) C Audio input/output D Serial port (The number and physical location of the serial ports may differ from one computer model to another.) Related topics Cable layout and interconnections, page 125 Installing the SY50 cables, page 135 467020/B 139 Simrad SY50 Installation Manual Processor Unit rear panel description: Nexcom NISE 3900E The rear panel of the Processor Unit holds the power socket and multiple interface ports. A DC power socket B Remote control C Serial ports (The number and physical location of the serial ports may differ from one computer model to another.) D Ethernet RJ45 connectors E Graphic adapter (DVI-D (Digital Visual Interface)) F USB 3.0 ports G Graphic adapter (HDMI (High-Definition Multimedia Interface)) Ethernet connectors The purpose of each Ethernet connector is predefined. ETH1 Simrad Connect Use this socket for Ethernet communication with other Simrad products. The Mk2 Operating Panel must be connected to this Ethernet socket. ETH2 Transceiver Use this socket for Ethernet communication with the relevant SY50 system unit in the sonar room. It is very important that a high-quality Ethernet cable is used. You must use CAT-5E STP (Shielded Twisted Pair) quality or better. Using cables with lower bandwidth capacity will reduce performance. ETH3 Ship network Use this socket if you want to connect your SY50 system to the ship’s local area network (LAN). 140 467020/B Cable layout and interconnections Serial line connectors Maximum length for an RS-232 serial cable is typically 60 meters with 2400 bps data rate, however this depends on the cable quality. Always check the cable manufacturers specifications for the actual "shunt capacitance". A common figure is 47.5 pF/m, which gives a maximum cable length of about 50 meters. Even though a standard exist for RS-232 pin configuration, certain manufacturer may still choose their own connector pins for the various signals used. In order to make the RS-232 connection to your peripheral device work properly, you must always consult the relevant instructions provided by the device manufacturer. Note Observe that long runs of unshielded cable will pick up noise easily. This is because the RS-232 signals are not balanced. COM1 This serial port is set up for RS422 communication. You can change to a different serial communication format in the computer BIOS. If you need to change these settings, as your local dealer or distributor for advice. You can also contact our support department. COM2 This serial port is set up for RS422 communication. You can change to a different serial communication format in the computer BIOS. If you need to change these settings, as your local dealer or distributor for advice. You can also contact our support department. COM3 This serial port is set up for RS232 communication. This serial communication format is fixed and cannot be changed. This serial port may not be fitted on all computer models. COM4 This serial port is set up for RS232 communication. This serial communication format is fixed and cannot be changed. Use USB-to-serial converters if additional serial lines are required. Several types are commercially available. Note that most USB-to-serial converters will introduce some latency. They may also introduce be jitter in the communication. The amount of jitter depends on the quality of the converter. 467020/B Pin RS232 RS422 RS485 1 DCD TX– DATA– 2 RX TX+ DATA+ 3 TX RX+ 4 DTR RX– 141 Simrad SY50 Installation Manual Pin RS232 RS422 RS485 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 RI Related topics Cable layout and interconnections, page 125 Installing the SY50 cables, page 135 142 467020/B Cable layout and interconnections Operating Panel connectors (Mk2) A dedicated Ethernet cable is used to connect the Operating Panel to the Processor Unit. A AC Power cable B Ethernet cable C Not used Related topics Cable layout and interconnections, page 125 Installing the SY50 cables, page 135 Operating Panel connectors (Mk3) The Mk3 Operating Panel is connected to the Processor Unit with a USB cable. Related topics Cable layout and interconnections, page 125 Installing the SY50 cables, page 135 467020/B 143 Simrad SY50 Installation Manual Cable drawings and specifications Topics C22 AC Power cable, page 145 C24 Control cable, page 146 C25 Transducer cable, page 147 AC power cable using IEC C13 inline socket, page 148 Ground cable, page 150 RS-232 serial line connection using three wires, page 151 RS-232 serial line connection using five wires, page 152 RS-232 used as synchronization trigger (input or output), page 153 RJ45 High speed Ethernet cable (1000Base-t), page 154 K-Sync interface to generic RS-232 synchronization input, page 155 Simrad TU40 interface to generic RS-232 synchronization input, page 157 About serial lines, page 159 144 467020/B Cable layout and interconnections C22 AC Power cable This cable must be provided by the installation shipyard. Minimum cable requirements • Conductors: 2 x 1.5 mm2 + 1.5 mm2 Ground • Screen: None • Voltage: 750 V • Maximum outer diameter: Defined by the plugs and/or the cable gland Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 467020/B 145 Simrad SY50 Installation Manual C24 Control cable This cable is included in the delivery. It comes pre-connected to the Power Supply Unit. The control cable is connected from the terminal block at the bottom of the Power Supply Unit to the terminal block inside the junction box. Each conductor inside the cable is identified with a number. Minimum cable requirements Not applicable. This cable is included in the delivery. Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 146 467020/B Cable layout and interconnections C25 Transducer cable This cable is included in the delivery. The cable is physically connected to the transducer. The transducer cable is connected to the terminal block at the bottom of the Power Supply Unit. The Ethernet wires must be terminated in a RJ45 plug and connected to the Ethernet switch. Minimum cable requirements Not applicable. This cable is included in the delivery. Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 467020/B 147 Simrad SY50 Installation Manual AC power cable using IEC C13 inline socket This cable is used to connect any unit or device to AC mains supply. The power cable is commercial. It is normally used for 115 and 230 VAC. The inline socket and the plug both comply to the IEC60320 standard. A IEC13 line socket - may be fitted with a locking device B CEE 7/7 male power plug C Live (normally identified with Blue insulation) D Neutral (normally identified with Brown insulation) E Ground (normally identified with Yellow or Yellow/Green insulation) A standard commercial AC mains cable is used. The power cable is normally terminated with an female IEC C13 inline socket. The AC mains end is terminated in an AC connector suitable for the local standard and/or the output sockets on an uninterruptible power supply (UPS). If this is not the case, you must replace the AC connector. The typical cable length is between 1,5 and 2 meters. If this is too short you must use an extension cable (not recommended), mount a new power outlet within range, or make your own power cable with sufficient length. If you use an uninterruptible power supply (UPS), you can also move the UPS to a different location within range. Note There are substantial differences between countries nomenclature related to power plugs and sockets. Observe local standards and regulations. 148 467020/B Cable layout and interconnections Minimum cable requirements • Conductors: 2 x 1.5 mm2 + 1.5 mm2 Ground • Screen: None • Voltage: 750 V • Maximum outer diameter: Defined by the plugs and/or the cable gland Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 467020/B 149 Simrad SY50 Installation Manual Ground cable Correct grounding is essential for safe operation and maximum performance. A Ground tag on unit B Vessel ground The ground connection is made using a thick stranded (or yellow/green) cable making a solid connection between the cabinet and the bulkhead. It is normally provided with a green/yellow colour. The grounding cable must be connected to vessel ground in the fuse box, or other common grounding point. Minimum cable requirements • Conductors: 1 x 6 mm2 • Screen: None • Voltage: 60 V • Maximum outer diameter: Not applicable Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 150 467020/B Cable layout and interconnections RS-232 serial line connection using three wires An RS-232 serial line connection using three (3) wires and NMEA datagrams is a common way to connect the SY50 system to external devices. A Local connection B Connection on remote device C Female 9-pin D-Subminiature connector D Male 9-pin D-Subminiature connector Unless otherwise specified, this cable must be provided by the installation shipyard. Note that this cable does not support all the signals in the standard RS-232 specification. Minimum cable requirements • Conductors: 2 x 4 x 0.5 mm2 • Screen: Overall braided • Voltage: 60 V • Maximum outer diameter: Defined by the plugs and/or the cable gland If you need to install a very long cable, increase the cross section. Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 About serial lines, page 159 467020/B 151 Simrad SY50 Installation Manual RS-232 serial line connection using five wires An RS-232 serial line connection using five (5) wires and NMEA datagrams is a common way to connect the SY50 system to external devices. A Local connection B Connection on remote device C Female 9-pin D-Subminiature connector D Male 9-pin D-Subminiature connector Unless otherwise specified, this cable must be provided by the installation shipyard. Note that this cable does not support all the signals in the standard RS-232 specification. Minimum cable requirements • Conductors: 2 x 4 x 0.5 mm2 • Screen: Overall braided • Voltage: 60 V • Maximum outer diameter: Defined by the plugs and/or the cable gland If you need to install a very long cable, increase the cross section. Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 About serial lines, page 159 152 467020/B Cable layout and interconnections RS-232 used as synchronization trigger (input or output) An RS-232 serial line connection using the Request To Send (RTS) and Clear To Send (CTS) signals is common way to connect the SY50 system to external devices for synchronization purposes. A Local connection B Connection on remote device C Female 9-pin D-Subminiature connector D Male 9-pin D-Subminiature connector This cable takes the control signals on a RS-232 serial line, and uses these as an external trigger. It provides interface with any peripheral unit that requires or controls transmit/receive synchronization. Note that this cable does not support all the signals in the standard RS-232 specification. Note This synchronization method can only be used with RS-232 communication. You can only connect two systems together. Unless otherwise specified, this cable must be provided by the installation shipyard. Minimum cable requirements • Conductors: 2 x 4 x 0.5 mm2 • Screen: Overall braided • Voltage: 60 V • Maximum outer diameter: Defined by the plugs and/or the cable gland If you need to install a very long cable, increase the cross section. Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 About serial lines, page 159 467020/B 153 Simrad SY50 Installation Manual RJ45 High speed Ethernet cable (1000Base-t) Most high speed data connections between the SY50 system units are made using Ethernet cables. These cables may also be used between the SY50 and peripheral equipment. A Local Ethernet connection B Connection on external network device Ethernet cables are available commercially in different lengths, colours and categories. Normally, CAT-5E and CAT-6 cables are used in local area networks with bandwidths exceeding 100 Mbit. Minimum cable requirements It is very important that high-quality Ethernet cables are used. You must use CAT-5E STP (Shielded Twisted Pair) quality or better. Using cables with lower bandwidth capacity will reduce performance. Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 154 467020/B Cable layout and interconnections K-Sync interface to generic RS-232 synchronization input For transmission synchronization purposes, the K-Sync will interface a generic RS-232 serial line communication port using the CTS (Clear To Send) and RTS (Request To Send) signals. The synchronized product is connected to the IO Module inside the K-Sync Synchronizing Unit. Each IO Module in the K-Sync Synchronizing Unit provides six connectors and a configuration board for physical adjustments of the communication parameters. Pin number Signal Signal description 1 Trigger Out This signal is transmitted to the system that needs to be synchronized. Trigger Out allows the system to transmit ("ping"). 2 Ground Mandatory! This ground is connected to pin 5 inside the IO Module. 3 RTT Ready to Transmit: Ready to Transmit (RTT) is a return signal from the hydroacoustic system that is synchronized. The Ready to Transmit (RTT) signal means that the hydroacoustic system is ready for the next trigger. 4 Trigger In This signal is received from the system that needs to be synchronized. Trigger In is "active" while the system is transmitting. 5 Ground Mandatory! This ground is connected to pin 2 inside the IO Module. 6 Not used A Local connection on the computer B Connections on the K-Sync IO Module 467020/B 155 Simrad SY50 Installation Manual A Connectors 1 through 6 as indicated by the arrows. Note that each of the two connector elements can be pulled out of the IO Module for easy access. B Configuration board Unless otherwise specified, this cable must be provided by the installation shipyard. Cable specifications Cable requirements may vary depending on the specific sonar you interface. Please consult the installation manual of the equipment for specific cable requirements. Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 156 467020/B Cable layout and interconnections Simrad TU40 interface to generic RS-232 synchronization input For transmission synchronization purposes, the Simrad TU40 will interface a generic RS-232 serial line communication port using the CTS (Clear To Send) and RTS (Request To Send) signals. The Trigger Unit provides one output and one input for each hydroacoustic system that needs to be synchronized. Each system is connected to the IO Module inside the Trigger Unit. Each IO Module in the Trigger Unit comprises an analog input module, a digital output module and a solid state relay module. Pin Signal Trigger Unit Signal description Screen(Green) Screen A Cable screen Input RTT B Ready to Transmit: Ready to Transmit (RTT) is a return signal from the hydroacoustic system that is synchronized. The Ready to Transmit (RTT) signal means that the hydroacoustic system is ready for the next trigger. Ground Ground C Signal ground Output Trigger Out D This signal is transmitted to the system that needs to be synchronized. Trigger Out allows the system to transmit ("ping"). Trigger Unit = Connections on the terminal block in the Trigger Unit A Local connection on the computer B Connections on the terminal block in the Trigger Unit (From left) 467020/B 157 Simrad SY50 Installation Manual A Screen (Cable screen) (Green) B Input (Ready to Transmit (RTT)) C Ground (Signal ground) D Output (Trigger Out) E Make the connections here. F Channels (From left) Minimum cable requirements Unless otherwise specified, this cable must be provided by the installation shipyard. If you need to install a very long cable, increase the cross section. • Conductors: 2 x 2 x 0.5 mm2 • Screen: Overall braided • Voltage: 60 V • Maximum outer diameter: Defined by the plugs and/or the cable gland Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 158 467020/B Cable layout and interconnections About serial lines A preferred method to establish communication between the SY50 system and peripheral devices, is by means of serial lines. Several serial line standards are available, each with different qualities. Unless otherwise specified, these cables must be provided by the installation shipyard. RS-232 serial communication An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. However, RS-232 is hampered by low transmission speed, large voltage swing, and large standard connectors. [...] Nevertheless, RS-232 devices are still used, especially in industrial machines, networking equipment and scientific instruments. https://en.wikipedia.org/wiki/RS-232 (September 2015) Maximum length for an RS-232 serial cable is typically 60 meters with 2400 bps data rate, however this depends on the cable quality. Always check the cable manufacturers specifications for the actual "shunt capacitance". A common figure is 47.5 pF/m, which gives a maximum cable length of about 50 meters. Note Most RS-232 cables do not support all the signals in the standard RS-232 specification. Observe that long runs of unshielded cable will pick up noise easily. This is because the RS-232 signals are not balanced. Even though a standard exist for RS-232 pin configuration, certain manufacturer may still choose their own connector pins for the various signals used. In order to make the RS-232 connection to your peripheral device work properly, you must always consult the relevant instructions provided by the device manufacturer. For more information about the RS-232 serial communication standard, see (for example): • https://en.wikipedia.org/wiki/RS-232 RS-422 serial communication While RS-232 is the most common serial interface for communicating with external devices using the NMEA standard, it only allows for one transmitter and one receiver on each line. RS-422 provides a mechanism for transmitting data up to 10 Mbits/s. This interface format uses a balanced signal on two wires. This increases both the maximum baud rate and the physical length of the cable, and it reduces the noise. With a high quality cable, you can use RS-422 on distances up to 1500 meters even in noisy environments. RS-422 is also specified for multi-drop applications. This means that one transmitter can send data to up to 10 receivers. 467020/B 159 Simrad SY50 Installation Manual Note There are no common standard for RS-422 pin configuration. Any manufacturer may choose their own connector pins for the various signals used. In order to make the RS-422 connection to your peripheral device work properly, you must always consult the relevant instructions provided by the device manufacturer. Use a cable with twisted pairs. For more information about the RS-422 serial communication standard, see (for example): • https://en.wikipedia.org/wiki/RS-422 RS-485 serial communication RS-485 (also known as TIA-485–A) is a standard defining the electrical characteristics of drivers and receivers for use in balanced digital multipoint systems. The standard is published by the Telecommunications Industry Association/Electronic Industries Alliance (TIA/EIA). Digital communications networks implementing the RS-485 standard can be used effectively over long distances and in electrically noisy environments. Multiple receivers may be connected to such a network in a linear, multi-drop configuration. RS-485 offers data transmission speeds of 35 Mbit/s up to 10 m and 100 kbit/s at 1200 m. Since it uses a differential balanced line over twisted pair (like RS-422), it can span relatively large distances (typically up maximum 1200 m). In contrast to RS-422, which has a single driver circuit which cannot be switched off, RS-485 drivers need to be put in transmit mode explicitly by asserting a signal to the driver. This allows RS-485 to implement linear bus topologies using only two wires. The equipment located along a set of RS-485 wires are interchangeably called nodes, stations or devices. RS-485, like RS-422, can be made full-duplex by using four wires. Since RS-485 is a multi-point specification, however, this is not necessary in many cases. Note There are no common standard for RS-485 pin configuration. Any manufacturer may choose their own connector pins for the various signals used. In order to make the RS-485 connection to your peripheral device work properly, you must always consult the relevant instructions provided by the device manufacturer. Use a cable with twisted pairs. For more information about the RS-485 serial communication standard, see (for example): • https://en.wikipedia.org/wiki/RS-485 160 467020/B Cable layout and interconnections Related topics Cable drawings and specifications, page 144 Cable layout and interconnections, page 125 RS-232 serial line connection using three wires, page 151 RS-232 serial line connection using five wires, page 152 RS-232 used as synchronization trigger (input or output), page 153 467020/B 161 Simrad SY50 Installation Manual Setting to work Topics Setting to work summary, page 163 Inspecting the installation of the SY50 system, page 165 Turning on the SY50 system for the first time, page 176 Placing each sensor in the vessel coordinate system, page 195 Inserting the installation parameters, page 203 Setting up the interfaces to peripheral devices, page 217 Configuring the SY50 system for normal operation, page 237 Defining the user-selected features on the Operating Panel, page 244 Testing the operating functionality of the SY50 system, page 251 Creating a backup with the SY50 configuration and software installation, page 268 Installation remarks, page 273 162 467020/B Setting to work Setting to work summary Once all the hardware units have been installed, and all the cables have been connected, the SY50 system can be turned on for the first time, and set to work. Prerequisites Before you can set the SY50 system to work, the following work must be finalized. • All hardware units have been installed according to the relevant instructions. • All system cables have been installed. • All connections have been made. • All operating power is available. • All peripheral devices that shall communicate with the SY50 system are available and operational. • All relevant personnel and tools are available. Context Some of these tasks may be done while the vessel is in dry dock. However, we assume that the vessel is set afloat before you start with the "setting to work" procedures. Note You must never turn on the SY50 system when the ship is in dry dock. The transducer may be damaged if it transmits in open air. It is therefore very important that the SY50 system remains turned off when the vessel is in dry dock, and that no one tries to use it. Procedure 1 Do a thorough visual inspection to make sure that the SY50 system is ready for operational use. a Make sure that all hardware units have been installed correctly. b Make sure that all the cables have been connected correctly. 2 Turn on the SY50 system for the first time. 3 Configure the SY50 system for operational use by inserting the relevant installation parameters. 4 Set up the interfaces with the external devices (navigation sensors and other peripherals). To provide correct information, the SY50 system needs to communicate with external devices. All these interfaces must be set up in the user interface. 5 Make sure that the SY50 system is fully operational To make sure that the SY50 system fulfils all operational and functional requirements, specific tests are provided. 467020/B 163 Simrad SY50 Installation Manual 6 Create a backup with the system configuration and software installation. Once the configuration and testing have been finalized, it is good practice to back up the configuration data and software installation. 7 Fill in and sign the Installation Remarks form, and return it to Kongsberg Maritime. Related topics Setting to work, page 162 Inspecting the installation of the SY50 system, page 165 Turning on the SY50 system for the first time, page 176 Placing each sensor in the vessel coordinate system, page 195 Inserting the installation parameters, page 203 Setting up the interfaces to peripheral devices, page 217 Configuring the SY50 system for normal operation, page 237 Defining the user-selected features on the Operating Panel, page 244 Testing the operating functionality of the SY50 system, page 251 Creating a backup with the SY50 configuration and software installation, page 268 Installation remarks, page 273 164 467020/B Setting to work Inspecting the installation of the SY50 system Topics Visual inspection of the display, page 165 Visual inspection of the Processor Unit, page 167 Visual inspection of the Operating Panel, page 168 Visual inspection of the Power Supply Unit, page 170 Visual inspection of the hull unit, page 171 Checking the environmental conditions in the sonar room, page 173 Making sure that all SY50 system cables are properly connected, page 174 Visual inspection of the display A visual inspection of the display is required to verify that the unit has not been physically damaged during the installation. Prerequisites The SY50 system hardware units are installed as specified in this manual. The SY50 system is turned off. You need the following equipment: • Multimeter Context This test procedure is only applicable when the display is provided by Kongsberg Maritime as a part of the SY50 delivery. Procedure 1 Make sure that the display is installed in the correct location, and that it is suitably orientated with respect to ambient light conditions and reflections. 2 Make sure that the physical installation of the unit has been completed. a Make sure that the structure to which the display is fastened is substantial enough to hold the unit securely under all operating conditions. b If applicable, make sure that the display (or the display mounting bracket) is bolted or welded securely to the deck and/or bulkhead. c If applicable: Make sure that ample ventilation is provided to avoid overheating. 467020/B 165 Simrad SY50 Installation Manual 3 d Make sure that ample space is provided around the unit to allow for maintenance and replacement of parts. e Make sure that the bolts, screws or studs that have been used are all of the correct size. f Make sure that the correct flat and shake-proof washers have been used. g Make sure that all the nuts have been tightened properly. h Make sure that all welds and brackets have been painted with the correct preservation medium to prevent corrosion. Make sure that the unit is not physically damaged, and that the surfaces and paint-work are clean without dents or scratches. The physical handling during the installation may have caused some minor scratches to the surfaces or paint-work. This can be accepted. However, if rough handling has caused serious damage, this must be recorded with a written statement and necessary photos, so that corrective actions can be made. 4 5 6 Make sure that the unit is firmly connected to ship's ground. a The unit must be connected to the ship's ground with an earthing strap. The strap must be in addition to any incidental electrical contact made by the mounting lugs on the unit. b Use a standard multimeter to check that the resistance between the unit and the ship's ground is approximately 0 (zero) Ω. Make sure that cable installation has been completed. a Make sure that all cables leading to and from the unit have been properly mounted and secured. b Make sure that enough slack has been provided on each cable to allow for maintenance and replacement. Make sure that the unit has been identified with the relevant product label(s), and that one label includes the part and serial numbers. Result Requirements Results The display is correctly installed with easy access for maintenance and replacement of parts. The display is free from scratches, dents or other physical damage. Free access to all the connectors on the display is provided. All cables are properly mounted with enough slack. The display is properly grounded. Date and signature: 166 467020/B Setting to work Related topics Setting to work, page 162 Inspecting the installation of the SY50 system, page 165 Visual inspection of the Processor Unit A visual inspection of the Processor Unit is required to verify that the unit has not been physically damaged during the installation. Prerequisites The SY50 system hardware units are installed as specified in this manual. The SY50 system is turned off. You need the following equipment: • Multimeter Procedure 1 Make sure that the computer is installed in the correct location, and that it is suitably oriented for replacement and cabling. 2 Make sure that the physical installation of the unit has been completed. 3 a Make sure that you have free access to rear and front side connectors on the computer for maintenance purposes. b Make sure that ample space is provided to open/close DVD and/or CD lids (if relevant), and to insert and remove USB flash drives. c If applicable: Make sure that ample ventilation is provided to avoid overheating. d Make sure that ample space is provided around the unit to allow for maintenance and replacement of parts. e Make sure that the bolts, screws or studs that have been used are all of the correct size. f Make sure that the correct flat and shake-proof washers have been used. g Make sure that all the nuts have been tightened properly. h If applicable: Make sure that all welds and brackets have been painted with the correct preservation medium to prevent corrosion. Make sure that the unit is not physically damaged, and that the surfaces and paint-work are clean without dents or scratches. The physical handling during the installation may have caused some minor scratches to the surfaces or paint-work. This can be accepted. However, if rough handling has caused serious damage, this must be recorded with a written statement and necessary photos, so that corrective actions can be made. 4 Make sure that the unit is firmly connected to ship's ground. 467020/B 167 Simrad SY50 Installation Manual 5 6 a Make sure that the unit is securely connected to the ship's ground with an earthing strap. The strap must be in addition to any incidental electrical contact made by the mounting lugs on the unit. b Use a standard multimeter to check that the resistance between the unit and the ship's ground is approximately 0 (zero) Ω. Make sure that cable installation has been completed. a Make sure that all cables leading to and from the unit have been properly mounted and secured. b Make sure that enough slack has been provided on each cable to allow for maintenance and replacement. Make sure that the unit has been identified with the relevant product label(s), and that one label includes the part and serial numbers. Result Requirements Results The Processor Unit is correctly installed with easy access for maintenance and replacement of parts. The Processor Unit is new, clean and free from scratches, dents or other physical damage. Free access to all the connectors on the Processor Unit is provided. All cables are properly mounted with enough slack. The Processor Unit can be fully opened for access to the internal parts. The Processor Unit is properly connected to vessel ground. Date and signature: Related topics Setting to work, page 162 Inspecting the installation of the SY50 system, page 165 Visual inspection of the Operating Panel A visual inspection of the Operating Panel is required to verify that the unit has not been physically damaged during the installation.. Prerequisites The SY50 system hardware units are installed as specified in this manual. The SY50 system is turned off. You need the following equipment: • Multimeter Procedure 1 168 Make sure that the Operating Panel is installed in the correct location, and that it is suitably oriented for easy maintenance and replacement of parts. 467020/B Setting to work 2 3 Make sure that the physical installation of the unit has been completed. a Make sure that ample space is provided around the unit to allow for maintenance and replacement of parts. b Make sure that the bolts, screws or studs that have been used are all of the correct size. c Make sure that the correct flat and shake-proof washers have been used. d Make sure that all the nuts have been tightened properly. Make sure that the unit is not physically damaged, and that the surfaces and paint-work are clean without dents or scratches. The physical handling during the installation may have caused some minor scratches to the surfaces or paint-work. This can be accepted. However, if rough handling has caused serious damage, this must be recorded with a written statement and necessary photos, so that corrective actions can be made. 4 5 6 Make sure that the unit is firmly connected to ship's ground. a Make sure that the unit is securely connected to the ship's ground with an earthing strap. The strap must be in addition to any incidental electrical contact made by the mounting lugs on the unit. b Use a standard multimeter to check that the resistance between the unit and the ship's ground is approximately 0 (zero) Ω. Make sure that cable installation has been completed. a Make sure that all cables leading to and from the unit have been properly mounted and secured. b Make sure that enough slack has been provided on each cable to allow for maintenance and replacement. Make sure that the unit has been identified with the relevant product label(s), and that one label includes the part and serial numbers. Result Requirements Results The Operating Panel is correctly installed with easy access for maintenance and replacement of parts. The Operating Panel is free from scratches, dents or other physical damage. Free access to all the connectors on the Operating Panel are provided. All cables are properly mounted with enough slack. Date and signature: Related topics Setting to work, page 162 Inspecting the installation of the SY50 system, page 165 467020/B 169 Simrad SY50 Installation Manual Visual inspection of the Power Supply Unit A visual inspection of the Power Supply Unit is required to verify that the unit has not been physically damaged during the installation. Prerequisites The SY50 system hardware units are installed as specified in this manual. The SY50 system is turned off. You need the following equipment: • Multimeter Procedure 1 Make sure that the Power Supply Unit is installed in the correct location, and that it is suitably oriented for easy maintenance and replacement of parts. 2 Make sure that the physical installation of the unit has been completed. 3 a Make sure that the cabinet door can be fully opened for unrestricted access. b Make sure that ample space is provided around the unit to allow for maintenance and replacement of parts. c Make sure that the bolts, screws or studs that have been used are all of the correct size. d Make sure that the correct flat and shake-proof washers have been used. e Make sure that all the nuts have been tightened properly. f Make sure that the welds and support brackets to which the unit is fastened are substantial enough to hold the it securely under all operating conditions. g Make sure that all welds and brackets have been painted with the correct preservation medium to prevent corrosion. Make sure that the unit is not physically damaged, and that the surfaces and paint-work are clean without dents or scratches. The physical handling during the installation may have caused some minor scratches to the surfaces or paint-work. This can be accepted. However, if rough handling has caused serious damage, this must be recorded with a written statement and necessary photos, so that corrective actions can be made. 4 5 Make sure that the unit is firmly connected to ship's ground. a Make sure that the unit is securely connected to the ship's ground with an earthing strap. The strap must be in addition to any incidental electrical contact made by the mounting lugs on the unit. b Use a standard multimeter to check that the resistance between the unit and the ship's ground is approximately 0 (zero) Ω. Make sure that cable installation has been completed. a 170 Make sure that all cables leading to and from the unit have been properly mounted and secured. 467020/B Setting to work b 6 Make sure that enough slack has been provided on each cable to allow for maintenance and replacement. Make sure that the unit has been identified with the relevant product label(s), and that one label includes the part and serial numbers. Result Requirements Results The Power Supply Unit is correctly installed with easy access for maintenance and replacement of parts. The Power Supply Unit is free from scratches, dents or other physical damage. Free access to all the connectors and/or cable glands on the Power Supply Unit is provided. All cables connected to the Power Supply Unit are properly mounted with enough slack. The Power Supply Unit can be fully opened, and you have full access to the circuit boards and modules inside the unit. The welds and brackets that support the Power Supply Unit are strong enough to hold the unit securely in place under all operating conditions. The welds and brackets have been painted with the correct preservation medium to prevent corrosion. The Power Supply Unit is properly grounded. Date and signature: Related topics Setting to work, page 162 Inspecting the installation of the SY50 system, page 165 Visual inspection of the hull unit A visual inspection of the hull unit is required to make sure that the unit has not been physically damaged during the installation. It is also important to check that the unit has been installed correctly. Prerequisites The SY50 system hardware units are installed as specified in this manual. The SY50 system is turned off. Context The transducer is covered with a thick red or black protective coating made of a special plastic type. The protective coating is a vital part of the transducer. It is very important that neither this coating nor the internal parts of the transducer are damaged during the handling, installation or cleaning. Any holes and/or scratches in the transducer surface will allow water to penetrate the transducer. If a leak occurs, the transducer must be replaced. 467020/B 171 Simrad SY50 Installation Manual Procedure 1 Make sure that the hull unit is installed in the correct location, and that it is suitably oriented for easy maintenance and replacement of parts. 2 Make sure that the unit is not physically damaged, and that the surfaces and paint-work are clean without dents or scratches. The physical handling during the installation may have caused some minor scratches to the surfaces or paint-work. This can be accepted. However, if rough handling has caused serious damage, this must be recorded with a written statement and necessary photos, so that corrective actions can be made. 3 Make sure that the unit has been identified with the relevant product label(s), and that one label includes the part and serial numbers. 4 Make sure that the physical installation of the unit has been completed. 5 6 a Make sure that the compartment ("sonar room") in which the hull unit is mounted is clean and dry. b Make sure that ample space is provided around the unit to allow for maintenance and replacement of parts. c Make sure that the bolts, screws or studs that have been used are all of the correct size. d Make sure that the correct flat and shake-proof washers have been used. e Make sure that all the nuts have been tightened properly. Make sure that cable installation has been completed. a Make sure that all cables leading to and from the unit have been properly mounted and secured. b Make sure that enough slack has been provided on each cable to allow for maintenance and replacement. c Make sure that the transducer cables can move freely when the transducer is lowered and hoisted. d Repeat the inspection of the transducer cables when the SY50 system is turned on and put to operational use. Make sure that there are no corrosive attacks on the hull unit, mounting flange, installation trunk, support brackets or other parts of the installation. Result Requirements Results The hull unit is correctly installed with easy access for maintenance and replacement of parts. The compartment in which the hull unit is installed ("sonar room") is clean and dry. All cables are properly mounted with enough slack. 172 467020/B Setting to work Requirements Results The transducer cables can move freely when the transducer is lowered and hoisted. There are no corrosive attacks. Date and signature: Related topics Setting to work, page 162 Inspecting the installation of the SY50 system, page 165 Checking the environmental conditions in the sonar room It is important that the sonar room is kept dry. The SY50 units must not be exposed to excessive temperatures, moisture or humidity. Such conditions can cause corrosive attacks and subsequent failures to the electronic circuitry. Prerequisites The following specific instruments are required for this task: • Thermometer • Hygrometer Procedure 1 Make sure that the compartment ("sonar room") is clean and dry. 2 Make sure that the ambient temperature in the room meets the environmental specifications. 3 a Make sure that the room is provided with ample ventilation to prevent system units from overheating. b Write down the type of ventilation system that is installed. c Make sure that the ambient temperature of the room is monitored. d Measure the ambient temperature in the room when the SY50 system is turned off. e Record the value in the result table. Make sure that the relative humidity in the room meets the environmental specifications. a Measure the relative humidity in the room. b Record the value in the result table. 467020/B 173 Simrad SY50 Installation Manual 4 30 minutes after the SY50 system was turned on and put to normal operation, measure the relative humidity one more time. Record the value in the result table. 5 30 minutes after the SY50 system was turned on and put to normal operation, measure the relative humidity one more time. Record the value in the result table. 6 Make sure that neither the room itself nor any of the system units have been subjected to corrosive attacks. Result The SY50 system is turned off. The SY50 system is turned on. Ambient temperature: Relative humidity: Related topics Setting to work, page 162 Inspecting the installation of the SY50 system, page 165 Making sure that all SY50 system cables are properly connected The SY50 system relies on communication between each unit, and between the SY50 system and external devices. It is very important that all cables are correctly installed, that the proper cable types have been used, and that all cables are connected correctly. Prerequisites The SY50 system hardware units are installed as specified in this manual. • The SY50 system is turned off. • All system cables are installed. • All cable connections are made. Neither tools nor instruments are required. Context All cabling is described in the Cable layout and interconnections chapter. Refer to the cable plan, the cable list and the basic cable requirements. 174 467020/B Setting to work Procedure 1 For each cable in use on the SY50 system: a Make sure that the cable is installed as specified in the Cable layout and interconnections chapter. Note Pay special attention to signal cables. These must not be installed too close to power cables. b Make sure that each Ethernet cable meets the relevant quality requirements. c Make sure that the terminations at each end of the cable are correct. d Make sure that the cable is properly identified. 2 Make sure that the transducer cables can move freely when the transducer is lowered and hoisted. 3 If irregularities are found, write these down in the in the Installation remarks table. Result Requirements Results Each cable is installed correctly. All cable connections are made. Each cable is properly identified. Each Ethernet cable in use meets quality requirement CAT5E STP (Shielded Twisted Pair) or better. The transducer cables can move freely when the transducer is lowered and hoisted. Date and signature: Related topics Setting to work, page 162 Inspecting the installation of the SY50 system, page 165 467020/B 175 Simrad SY50 Installation Manual Turning on the SY50 system for the first time Topics Making sure that the operating power is correct, page 176 Installing the operating software, page 177 Obtaining and installing a software license for additional functionality, page 178 Setting up the Operating Panel (Mk2), page 179 Using more than one Operating Panel to control the sonar (Mk2), page 182 Using a single Operating Panel to control more than one sonar (Mk2), page 186 Turning on the entire SY50 system for the first time, page 190 Turning on the SY50 system for normal use, page 193 Making sure that the operating power is correct The SY50 system operates on AC power from the vessel’s mains supply. Before you connect AC power to any system unit, you must make sure that the voltage is correct. Prerequisites Before you can do this task, the following prerequisites must be met: • All hardware units have been installed according to the relevant instructions. • All system cables have been installed. • All operating power is available. • All relevant personnel (ships electrician) and tools (for example a voltmeter) are available. Procedure 1 For each system unit that operates on AC mains: a If necessary: Measure the voltage. b Make sure that the relevant system unit can operate on the mains power provided. 2 Make sure that the circuit breaker on the power circuit can handle the load when the SY50 system is turned on. 3 Make sure that the uninterruptible power supply (UPS) can supply enough power to the SY50 system. 176 467020/B Setting to work Installing the operating software A dedicated wizard is used to install the software. The Processor Unit is shipped without the SY50 software installed. The operating system has been modified to make the computer work with the SY50 system. Prerequisites The following specific items are required for this task: • Software media (USB flash drive) (included with delivery) • Software license code (if applicable) Neither tools nor instruments are required. This procedure is made for the Microsoft® Windows® 10 operating system. It is assumed that you are familiar with this operating system. Procedure 1 Turn on the Processor Unit. 2 Make the following preparations. 3 a If applicable: Connect the keyboard and the mouse to USB sockets on the front panel of the Processor Unit. b Insert the USB flash drive. Install the operating software. a From the Windows® Start button, right-click to open File Explorer. b Locate the application file. c Copy the file to a temporary folder on the "C" drive. d Double-click the setup executable file to start the installation. e Select the check box to accept the license terms and conditions. f Select Install. g Follow the instructions provided by the wizard. We recommend that you install the software in the default folder suggested by the wizard. h Close File Explorer. i Remove the USB flash drive. 4 On the Processor Unit desktop, double-click the SY50 icon to start the program. 5 If applicable: Disconnect the keyboard and the mouse from the Processor Unit. 467020/B 177 Simrad SY50 Installation Manual Obtaining and installing a software license for additional functionality The SY50 system does not need any software licenses to operate. However, specific software license codes "unlocks" additional functionality. Context The software license is a 32 character hexadecimal string based on the hardware identifier (Hardware ID). This unique identifier is generated using information from key components in the computer. The software license is linked to the physical computer. You cannot move the SY50 system software from one Processor Unit to another unless you also request and install a new license. In order to obtain a software license you must contact one of our dealers or distributors. You can also use the request form on our website, or contact our support department directly. Note Once you receive your software license string(s), do not lose them. We suggest that you copy the information into a text file (for example Notepad), and add relevant information. Place the text file on the computer desktop, and make sure that backup copies are made. When you work in the Installation dialog box, you must always select Apply to save the changes made on a page. You must do this before you continue working on a different page. The following licensing options are available for the SY50 system: NetCDF The SY50 system supports netCDF4, where the number refers to the version of the format. SONAR-NetCDF4 is a data and metadata convention for storage of data from active sonars in NetCDF4 formatted files, defined by The International Council for the Exploration of the Sea (ICES). Sonar-NetCDF4 consists primarily of a naming convention and a data structure within the NetDCF4 data model. Procedure 1 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 2 On the left side of the Installation dialog box, select Software License. Observe that the Software License page opens. 3 Obtain the necessary information about your SY50 system: • Hardware ID 178 467020/B Setting to work 4 Send the information to one of our dealers or distributors. You can also use the request form on our website, or contact our support department directly. You can use the following e-mail address: • [email protected] Once the software license string(s) have been returned to you (most likely by e-mail), you can install the licenses into the software. 5 Open the Software License page. 6 Select Type License String, and type the license string into the dialog box. If you do not have a computer keyboard connected to your SY50 system, select the Keyboard button to open an on-screen keyboard. If you have received the license string on an electronic format (e-mail or text file), you can copy the string from the source document and paste it into the Type License String dialog box. 7 Select OK to save the license string and close the Type License String dialog box. 8 Verify that the license string is placed in the Currently active licenses list. If necessary, select the license string on the left side, and click the arrow button [>] to move it to the Currently active licenses list. 9 Select Apply and then Close to save all the parameters and close the Installation dialog box. Setting up the Operating Panel (Mk2) The Operating Panel offers all necessary control functions for normal operation. Before it can be put to use, the Mk2 Operating Panel must be configured to permit Ethernet communication between the panel and the Processor Unit. Prerequisites The Operating Panel is installed as specified in this manual. The Processor Unit is turned on. The following specific items are required for this task: • Computer mouse • Computer keyboard Neither tools nor instruments are required. Context When supplied, the Operating Panel is set up with the following communication parameters: • IP Address: 157.237.60.20 • Subnet mask: 255.255.255.0 • Gateway: 157.237.60.1 467020/B 179 Simrad SY50 Installation Manual To set up the Ethernet communication, you must define the IP address for the panel, and identify the Processor Unit in the panel software. These settings allow you to use more than one Operating Panel on the Processor Unit. You can also control more than one Processor Unit from a single Operating Panel. The IP and MAC addresses for your Processor Unit are contained in a text file named IPandMACaddress.txt. The file contains the product name, IP address and MAC address in the following format (example): SY50 157.237.60.14 AC:1F:6B:1D:42:E6 If the text file is missing you must find the information manually. We suggest that you do this, and create the necessary folder and txt file before you start the setup process. See step 1 in the procedure. Note If the Operating Panel fails to establish contact with the Processor Unit it will time out and switch itself off after two minutes. When this happens the blue indicator light stops flashing. Procedure If required, locate the IP and MAC addresses on the ETH1 Ethernet adapter in the Processor Unit. 1 Obtain the IP address. The IP and MAC addresses for your Processor Unit are contained in a text file named IPandMACaddress.txt. If the text file is missing you must find the information manually. a In the bottom-left corner of your desktop, select the Windows® Start button. b On the menu, select Settings. c Observe that the Windows Settings dialog box opens. d Select Network & Internet. e Select Change adapter options. f Select the relevant network adapter, then right-click and select Properties on the short-cut menu. g On the list of connections, select Internet Protocol 4 (TCP/IPv4), and then Properties. h Observe the IP address for the Ethernet adapter. i Write down the information. j Close all the dialog boxes. Obtain the MAC address. 180 467020/B Setting to work a In the bottom left corner of your desktop, select the looking glass to start a search. b Type "Command", do the search, and open the Command Prompt window. c Type ipconfig /all and press the Enter key. d Observe the "Physical Address" (MAC address) for the relevant Ethernet adapter. e Write down the information. f Close the Command Prompt window. Select the adapter that the Operating Panel is connected to. On the SY50 system, the Ethernet adapter is named Simrad Connect. Prepare the Operating Panel for use. 2 3 4 Make the following preparations. a Connect the power cable from the Operating Panel to the power outlet on the uninterruptible power supply (UPS). b Connect the Ethernet cable from the Processor Unit to the Operating Panel. Make sure that you use the correct Ethernet socket on the rear side of the Processor Unit: ETH1 c Connect the keyboard and the mouse to USB sockets on the front panel of the Processor Unit. d On the Processor Unit, close any programs that are running, and return to the desktop. e On the Operating Panel, press Power, and keep it depressed for a few seconds. The blue indicator light in the button flashes while the Operating Panel establishes contact with the Processor Unit. When you start the panel for the first time the interface must be configured to establish this connection. When the connection has been made, the blue indicator light is lit permanently. f On the Processor Unit desktop, open folder SIMRAD-Shortcut. g Double-click file IPandMACaddress.txt to open it in a text editor. h Double-click the URL shortcut to open the Operating Panel configuration page in the default web browser. i Observe that the Operating Panel configuration page opens on page 157.237.60.20:5000. Define the configuration parameters. a Select SOP Configuration on the top menu to open the page. b Observe the default values. If you wish to keep these default values, do nothing. The default values are well suited if you have one single panel communicating with one single Processor Unit. For other configurations, see the relevant procedures. Add a single Processor Unit to the Operating Panel configuration. 467020/B 181 Simrad SY50 Installation Manual 5 a Select Sonar PCs Configuration on the top menu to open the page. b Type or copy the IP address into the relevant box. c Type or copy the MAC address into the relevant box. d Select ADD Sonar PC. e Observe that your Processor Unit is added to the list. f Close the web browser. Make sure that the Operating Panel is functional. a Make sure that the blue indicator is lit, and check that you can move the cursor on the screen. b On the Processor Unit desktop, double-click the SY50 icon to start the program. Wait until the SY50 system operates normally. c Press and hold Power depressed four minimum four seconds to turn off the Operating Panel. Observe that the Transceiver On/Off dialog box opens automatically. Make sure that the SY50 system is turned off. d Turn on the SY50 system with the Power button on the Operating Panel. e Make sure that you can control the cursor, and that you can make selections in the menu system. f Press and/or turn selected buttons, and make sure that the corresponding function is activated in the user interface. Using more than one Operating Panel to control the sonar (Mk2) A secondary Operating Panel may be connected to the Processor Unit. This may be useful in conjunction with a second display if you wish to control the SY50 system from two different locations on your vessel. Prerequisites The Operating Panel is installed as specified in this manual. The Processor Unit is turned on. The following specific items are required for this task: • Computer mouse • Computer keyboard • Ethernet switch Make sure that your selected Ethernet switch has a large bandwidth capacity. Minimum 1 Gb (1000BASE-T) is required. • Ethernet cables 182 467020/B Setting to work It is very important that high-quality Ethernet cables are used. You must use CAT-5E STP (Shielded Twisted Pair) quality or better. Neither tools nor instruments are required. Context When supplied, the Operating Panel is set up with the following communication parameters: • IP Address: 157.237.60.20 • Subnet mask: 255.255.255.0 • Gateway: 157.237.60.1 The IP and MAC addresses for your Processor Unit are contained in a text file named IPandMACaddress.txt. The file contains the product name, IP address and MAC address in the following format (example): SY50 157.237.60.14 AC:1F:6B:1D:42:E6 Tip If the distance between the Processor Unit and your second display is considerable, we suggest that you use KVM (Keyboard Video Mouse) technology to preserve the video quality. Procedure 1 Make the following preparations. a On the Processor Unit, close any programs that are running, and return to the desktop. b Insert the Ethernet switch between the Operating Panel and the Processor Unit. Make sure that you use the correct Ethernet socket on the rear side of the computer: ETH1 c Install the secondary Operating Panel. d Connect the Operating Panel to AC mains. e Connect the power cable from the Ethernet switch to the AC power outlet. f Do not connect the Operating Panel to the Ethernet switch. 467020/B 183 Simrad SY50 Installation Manual Ethernet cables Tip An Ethernet switch connected to ETH1 on the rear side of the Processor Unit can also be used to interface other peripheral systems such as echo sounders and positioning systems. You can also connect the Olex system to the SY50 system using this Ethernet switch. 2 Change the IP Address on the primary Operating Panel. Note Each Operating Panel must have a different IP Address. None of the panels must use the default IP Address. If you have previously changed the IP Address on the Operating Panel, you can proceed to the next step. a On the Operating Panel, press Power, and keep it depressed for a few seconds. The blue indicator light in the button flashes while the Operating Panel establishes contact with the Processor Unit. When the connection has been made, the blue indicator light is lit permanently. b On the Processor Unit desktop, open folder SIMRAD-Shortcut. c Double-click the URL shortcut to open the Operating Panel configuration page in the default web browser. d Select SOP Configuration on the top menu to open the page. e In the SOP IP field, change the IP Address from the default value to: 157.237.60.xx The last digit "xx" in the IP Address can be any number between 21 and 29. Note Each Operating Panel must have a different IP Address. None of the panels must use the default IP Address. 184 467020/B Setting to work f Select Apply IP Configuration. When the new IP Address has been set in the Operating Panel, you will loose contact with the configuration page. 3 g To re-establish contact, use the following URL in your browser: 157.237.60.xx:5000 h Select Sonar PCs Configuration on the top menu to open the page. i Make sure that the IP and MAC Addresses to the Processor Unit are correct, and that the Processor Unit is present on the list. j Close the web browser. Connect and set up the secondary Operating Panel. a Connect the Operating Panel to the Ethernet switch. b On the Operating Panel, press Power, and keep it depressed for a few seconds. The blue indicator light in the button flashes while the Operating Panel establishes contact with the Processor Unit. When you start the panel for the first time the interface must be configured to establish this connection. When the connection has been made, the blue indicator light is lit permanently. c On the Processor Unit desktop, open folder SIMRAD-Shortcut. d Double-click the URL shortcut to open the Operating Panel configuration page in the default web browser. e Select SOP Configuration on the top menu to open the page. f In the SOP IP field, change the IP Address from the default value to: 157.237.60.xx The last digit "xx" in the IP Address can be any number between 21 and 29. Note Each Operating Panel must have a different IP Address. None of the panels must use the default IP Address. g Select Apply IP Configuration. When the new IP Address has been set in the Operating Panel, you will loose contact with the configuration page. h To re-establish contact, use the following URL in your browser: 157.237.60.xx:5000 i Select Sonar PCs Configuration on the top menu to open the page. j Obtain the IP address. k Type or copy the IP address into the relevant box. l Obtain the MAC address. m Type or copy the MAC address into the relevant box. 467020/B 185 Simrad SY50 Installation Manual 4 n Select ADD Sonar PC. o Observe that your Processor Unit is added to the list. p Close the web browser. Make sure that each Operating Panel is functional. a Make sure that the blue indicator is lit, and check that you can move the cursor on the screen. b On the Processor Unit desktop, double-click the SY50 icon to start the program. Wait until the SY50 system operates normally. c Make sure that you can control the cursor, and that you can make selections in the menu system. d Press and/or turn selected buttons, and make sure that the corresponding function is activated in the user interface. Using a single Operating Panel to control more than one sonar (Mk2) Since the Mk2 Operating Panel uses Ethernet to communicate with the Processor Unit, you can use one single panel to control more than one sonar system. Prerequisites The Operating Panel is installed as specified in this manual. The Processor Unit is turned on. The following specific items are required for this task: • Computer mouse • Computer keyboard • Ethernet switch Make sure that your selected Ethernet switch has a large bandwidth capacity. Minimum 1 Gb (1000BASE-T) is required. • Ethernet cables It is very important that high-quality Ethernet cables are used. You must use CAT-5E STP (Shielded Twisted Pair) quality or better. Neither tools nor instruments are required. Context When supplied, the Operating Panel is set up with the following communication parameters: • IP Address: 157.237.60.20 186 467020/B Setting to work • Subnet mask: 255.255.255.0 • Gateway: 157.237.60.1 The IP and MAC addresses for your Processor Unit are contained in a text file named IPandMACaddress.txt. The file contains the product name, IP address and MAC address in the following format (example): SY50 157.237.60.14 AC:1F:6B:1D:42:E6 Tip To change which sonar to control, press Sonar Select on the Operating Panel. If you use your Operating Panel to control more than two sonars, press Sonar Select repeatedly to select. Procedure 1 Make the following preparations. a Insert the Ethernet switch between the Operating Panel and the Processor Unit. Make sure that you use the correct Ethernet socket on the rear side of the computer: ETH1 b Connect each Processor Unit to the same Ethernet switch. Make sure that you use the correct Ethernet socket on the rear side of the computer: ETH1 c Connect the power cable from the Ethernet switch to the AC power outlet. Ethernet cables 467020/B 187 Simrad SY50 Installation Manual Tip An Ethernet switch connected to ETH1 on the rear side of the Processor Unit can also be used to interface other peripheral systems such as echo sounders and positioning systems. You can also connect the Olex system to the SY50 system using this Ethernet switch. 2 Open the Operating Panel configuration page. a On the Operating Panel, press Power, and keep it depressed for a few seconds. The blue indicator light in the button flashes while the Operating Panel establishes contact with the Processor Unit. When the connection has been made, the blue indicator light is lit permanently. b On the Processor Unit, close any programs that are running, and return to the desktop. c On the Processor Unit desktop, open folder SIMRAD-Shortcut. d Double-click the URL shortcut to open the Operating Panel configuration page in the default web browser. Note If you have previously changed the IP Address on the Operating Panel, you must use this address to open the configuration page. For each Processor Unit that is added: 3 Locate the IP and MAC addresses on the ETH1 Ethernet adapter in the Processor Unit. The IP and MAC addresses for your Processor Unit are contained in a text file named IPandMACaddress.txt. If the text file is missing you must find the information manually. Obtain the IP address. 188 a In the bottom-left corner of your desktop, select the Windows® Start button. b On the menu, select Settings. c Observe that the Windows Settings dialog box opens. d Select Network & Internet. e Select Change adapter options. f Select the relevant network adapter, then right-click and select Properties on the short-cut menu. g On the list of connections, select Internet Protocol 4 (TCP/IPv4), and then Properties. h Observe the IP address for the Ethernet adapter. i Write down the information. j Close all the dialog boxes. 467020/B Setting to work Obtain the MAC address. a In the bottom left corner of your desktop, select the looking glass to start a search. b Type "Command", do the search, and open the Command Prompt window. c Type ipconfig /all and press the Enter key. d Observe the "Physical Address" (MAC address) for the relevant Ethernet adapter. e Write down the information. f Close the Command Prompt window. Select the adapter that the Operating Panel is connected to. On the SY50 system, the Ethernet adapter is named Simrad Connect. 4 5 Add a single Processor Unit to the Operating Panel configuration. a Select Sonar PCs Configuration on the top menu to open the page. b Type or copy the IP address into the relevant box. c Type or copy the MAC address into the relevant box. d Select ADD Sonar PC. e Observe that your Processor Unit is added to the list. f Close the web browser. Make sure that the Operating Panel is functional. a Make sure that the blue indicator is lit, and check that you can move the cursor on the screen. b On the computer desktop, double-click the SY50 icon to start the program. c Press Sonar Select on the Operating Panel. d Make sure that you can control the cursor, and that you can make selections in the menu system. e Press and/or turn selected buttons, and make sure that the corresponding function is activated in the user interface. 467020/B 189 Simrad SY50 Installation Manual Turning on the entire SY50 system for the first time When the relevant system units have been turned on individually, you can turn on the entire system for the first time. It is very important that this does not take place while the vessel is in dry dock. The transducer may be damaged if it transmits in open air. In order to turn on the SY50 system for the first time in a controlled manner, two tasks must be done simultaneously. Two persons are needed. • One person must stay on the bridge in order to operate the SY50 system. • One person must stay in the sonar room to make sure that the SY50 system starts, and that the hull unit works properly. Proper oral communication must exist between the bridge and the sonar room. Certain steps in the procedures are location specific. The steps marked [Sonar room] are done in the sonar room. The steps marked [Bridge] are done on the bridge. WARNING The transducer may be damaged if it transmits in open air. Topics Turning on the entire system: Preparations, page 190 Turning on the entire system: Bridge steps, page 191 Turning on the entire system: Sonar room steps, page 192 Turning on the entire system: Preparations Before you can turn on the entire SY50 system, you must check all the cables and connections. Prerequisites The SY50 system is installed as specified in this manual. • The door on the Power Supply Unit is open. • Neither tools nor instruments are required. Context Certain steps in the procedures are location specific. The steps marked [Sonar room] are done in the sonar room. The steps marked [Bridge] are done on the bridge. Procedure 1 190 Make sure that the Ethernet cable from the Processor Unit to the Power Supply Unit is firmly connected. 467020/B Setting to work 2 Make sure that the transducer cable is connected to the terminal block and the Ethernet switch inside the Power Supply Unit. 3 Make sure that the transducer can be lowered and hoisted without complications or obstacles. 4 Make sure that the transducer cable can move freely when the transducer is lowered and hoisted. Related topics Turning on the entire SY50 system for the first time, page 190 Turning on the entire system: Bridge steps These tasks are done on the bridge. Context Certain steps in this procedure are location specific. The steps marked [Sonar room] are done in the sonar room. Procedure 1 Make sure that you have sufficient water depth below the keel before you lower the transducer. 2 Turn on the SY50 system. a Turn on the display(s). b Turn on the Processor Unit. The blue indicator light in the button flashes while the Operating Panel establishes contact with the Processor Unit. When the connection has been made, the blue indicator light is lit permanently. Wait while the operating system and SY50 program is loaded and started. The Processor Unit, Power Supply Unit and transducer are all turned on automatically. c 3 Once the program has started, observe that the display presentation fills the entire screen. Lower the transducer to its bottom position. a 467020/B On the Operating Panel, press Down. 191 Simrad SY50 Installation Manual b [Sonar room]: When the transducer shaft stops, verify that the correct bottom position has been reached. 4 On the Horizontal menu, set Range to a suitable range. 5 Set Mode to Bow Up. 6 Start "pinging". a Set Tx Power to Low. b Make sure that echoes appear on the display presentation. c Set Tx Power to Medium. d Make sure that echoes on the display presentation appear stronger. e Set Tx Power to Maximum. f Make sure that echoes on the display presentation appear even stronger. 7 Set Tx Power to Off. 8 Hoist the transducer to its upper position. a On the Operating Panel, press Up. b [Sonar room]:When the transducer shaft stops, verify that the correct upper position has been reached. 9 Notify the sonar room that the test is finished. 10 [Sonar room]: Close the Power Supply Unit. Further requirements After these tasks, the SY50 system is turned on, but it is not transmitting ("pinging"). The transducer is hoisted to its upper position. If you wish to proceed with the setting to work tasks, leave the SY50 system in this state. If you wish to proceed later, turn the SY50 system off. Related topics Turning on the entire SY50 system for the first time, page 190 Turning on the entire system: Sonar room steps These tasks are done in the sonar room. Context Certain steps in this procedure are location specific.The steps marked [Bridge] are done on the bridge. 192 467020/B Setting to work Procedure 1 [Bridge]: Make sure that you have sufficient water depth below the keel before you lower the transducer. 2 [Bridge]: Turn on the SY50 system. 3 [Bridge]: Lower the transducer to its bottom position. a [Bridge]: On the Operating Panel, press Down. b When the transducer shaft stops, verify that the correct bottom position has been reached. 4 [Bridge]: On the Horizontal menu, set Range to a suitable range. 5 [Bridge]: Set Mode to Bow Up. 6 [Bridge]: Start "pinging". a [Bridge]: Set Tx Power to Low. b [Bridge]: Make sure that echoes appear on the display presentation. c [Bridge]: Set Tx Power to Medium. d [Bridge]: Make sure that echoes on the display presentation appear stronger. e [Bridge]: Set Tx Power to Maximum. f [Bridge]: Make sure that echoes on the display presentation appear even stronger. 7 [Bridge]: Set Tx Power to Off. 8 [Bridge]: Hoist the transducer to its upper position. a [Bridge]: On the Operating Panel, press Up. b When the transducer shaft stops, verify that the correct upper position has been reached. 9 [Bridge]: Notify the sonar room that the test is finished. 10 Close the Power Supply Unit. Related topics Turning on the entire SY50 system for the first time, page 190 Turning on the SY50 system for normal use To use the SY50 system, you must first turn it on. The SY50 program starts automatically when the Processor Unit is turned on. Caution You must never permit the SY50 system to transmit (ping) when the ship is in dry dock. The transducer may be damaged if it transmits in open air. 467020/B 193 Simrad SY50 Installation Manual Procedure 1 Make sure that you have sufficient water depth below the keel before you lower the transducer. 2 Turn on the display(s). If required, refer to the instructions provided by the display manufacturer. 3 Turn on the Processor Unit. The blue indicator light in the button flashes while the Operating Panel establishes contact with the Processor Unit. When the connection has been made, the blue indicator light is lit permanently. Wait while the operating system and SY50 program is loaded and started. The Processor Unit, Power Supply Unit and transducer are all turned on automatically. 4 Observe that the Transceiver On/Off dialog box opens automatically. The dialog box offers progress information. A blue circle on the hull unit symbol means that the Processor Unit communicates with the hull unit control circuitry. 5 Once the program has started, observe that the display presentation fills the entire screen. The program starts up using the same settings as the last time you used it. If these settings are acceptable, continue operation. If you wish to alter any of the settings, see the relevant procedures. 6 To lower the transducer, press Down on the Operating Panel. While the transducer is moving the indicator lamp flashes, and an audible signal is sounded. When the requested position has been reached, the indicator lamp is lit, and the audible signal stops. Alternatively, use the Hull Unit function on the top bar to lower the transducer. 7 At the bottom of the Main menu, observe that the Operation icon is flashing. The icon is flashing to indicate that even if the SY50 system is turned on, "pinging" is disabled. The SY50 system is in Normal mode, but TX Power is set to Off to prevent transmissions. This is for safety reasons. 8 194 Set Tx Power to Maximum (or any other power rating) to start pinging. 467020/B Setting to work Placing each sensor in the vessel coordinate system Topics Dimensional surveying, page 195 Surveying the transducer and the navigation sensors, page 196 Example procedure, page 197 Vessel coordinate system, page 200 Dimensional surveying Several sensors are connected to the SY50 system to make its operation as accurate as possible. These sensors are physically located on different places on the vessel. Typical sensors are those providing navigational information (heading, speed or geographical position) or vessel movements in the sea (motion sensors). In order to "move" these sensors to a common location on the vessel a vessel coordinate system is defined. The relative location of each sensor is then measured and referenced to this coordinate system. This is commonly referred to as dimensional surveying. Why is this important? When a sensor makes a measurement, the information is always related to the physical position of the sensor. This introduces an error since this is not the physical location of neither you nor the SY50 system. On small vessels, these measurement errors are often negligible. On larger vessels, however, the distances between the sensors are greater, and the errors can affect the accuracy of the SY50 system. The errors become extra noticeable when the vessel moves in heavy seas. Example The antenna of a position sensor is typically mounted high above the superstructure, while a motion sensor is located close to the vessel’s centre of gravity. Both of these are physically positioned far away from the transducer, which may be located closer to the bow. If you have an echo sounder transducer located close to the bow, the measured depth will change considerably when the bow is subjected to heave in heavy seas. In order reduce the measurement errors you can do this: • Install and use a motion reference unit (MRU) to detect the movements of the vessel. • Define a vessel coordinate system, and place all the sensors in it. 467020/B 195 Simrad SY50 Installation Manual Dimensional surveying The dimensional surveying tasks recommended for the SY50 system include: • Define the vessel coordinate system. The vessel coordinate system is established to define the relative physical locations of system units and sensors. When you have several different sensors and transducers on your vessel, and you wish each of them to provide accurate data, you need to know their relative physical positions. • Define the location of the origin in the coordinate system. The origin is the common reference point where all three axis in the vessel coordinate system meet. All physical locations of the vessel’s sensors (radar and positioning system antennas, echo sounder and sonar transducers, motion reference units, etc.) are referenced to the origin. • Define the vessel’s centre line. • Measure the physical location of each sensor (or sensor antenna). By means of the vessel coordinate system, the physical location of every sensor can be defined using three numerical values for X, Y and Z. These values must define the vertical and horizontal distances from a single reference point; the origin. The accuracy of the three numerical values for X, Y and Z defines the accuracy of the sensor data. • Measure the physical location and orientation of each sensor (or sensor antenna). Place it in the coordinate system. Measure the physical location of each transducer. Place it in the coordinate system. Related topics Vessel coordinate system, page 200 Placing each sensor in the vessel coordinate system, page 195 Surveying the transducer and the navigation sensors An overall procedure specifying the main tasks is provided. It is not within the scope of this publication to provide detailed instructions for dimensional surveying. Consult the installation shipyard and/or a naval architect if you need detailed instructions. Prerequisites For accurate ship dimensions you need the detailed vessel drawings. Context Determining the relative positions of the sensors and each transducer is important. Sufficient time and satisfactory work conditions must be given to the survey work. The installation engineers from Kongsberg Maritime and from our authorized dealers are neither equipped nor trained to do dimensional surveying. 196 467020/B Setting to work All measurements must be made after the installation of the transducer and the navigation sensors Procedure 1 Define the vessel coordinate system. 2 Define the location of the origin in the coordinate system. If required, identify the location with a physical marking. 3 Set out the required coordinate reference points throughout the vessel. 4 Define the vessel’s centre line. If required, identify the line with physical markings. 5 Measure the physical location of each transducer. 6 Measure the physical location of the motion reference unit (MRU). 7 Measure the physical location of the global positioning system (GPS) antenna. Result The information provided by the dimensional survey is entered into the SY50 software as installation parameters. Related topics Vessel coordinate system, page 200 Placing each sensor in the vessel coordinate system, page 195 Example procedure It is not within the scope of this publication to provide detailed instructions for dimensional surveying. However, an example procedure is provided to help you understand how it is done. Prerequisites For accurate ship dimensions you need the detailed vessel drawings. You need a printed version of each drawing. Each drawing must be to scale. 467020/B 197 Simrad SY50 Installation Manual Procedure 1 Define the location of the origin in the coordinate system. The origin is the common reference point where all three axis in the vessel coordinate system meet. All physical locations of the vessel’s sensors (radar and positioning system antennas, echo sounder and sonar transducers, motion reference units, etc.) are referenced to the origin. In most cases, the location of the vessel’s "official" origin has been defined by the designer or shipyard. This origin is normally identified with a physical marking, and also shown on the vessel drawings. In this example we will establish the origin at the same physical location as the skipper’s seat on the bridge, however virtually moved down to the waterline. The seat is located two metres to the starboard side of the vessel’s centre line. All sensors will then be referenced to this position. • The depth readout from an echo sounder will be the Depth Below Surface (DBS) value contained in the NMEA DBS datagram. • Whenever a sonar is used with short ranges, this will provide a more precise presentation. If required, identify the location with a physical marking. 2 Measure the physical location and orientation of each transducer. The transducers are located in a blister under the keel. The blister is placed on the vessel’s centre line, and close to the bow. Note In this context, the transducer is regarded as a sensor. a Draw a vertical line from the transducer and up. b Measure the vertical distance from the waterline and down to the transducer face. This is the Z value. The value is positive because the sensor is located under the origin. c Measure the horizontal distance in parallel with the X axis from the origin to the vertical line. This is the X value. The value is positive because the sensor is located in front of the origin. 198 467020/B Setting to work d Measure the horizontal distance in parallel with the Y axis from the origin to the centre line. The sensor is on the centre line, but the origin is located on the starboard side. This is the Y value. The value is negative because the sensor is located on the port side of the origin. e 3 Type the values you have found for X, Y and Z into the Transducer page when you install the transducer in the SY50 user interface. Measure the physical location of the global positioning system (GPS) antenna. There are two GPS antennas. Both are placed on the main mast, one on each side, each two meters from the mast. The mast is located on the top of the bridge, aft of origin. We will measure the coordinates to the port antenna. Note In this context, the GPS antenna is regarded as the sensor. a Draw a vertical line from the sensor and down. b Measure the vertical distance from the waterline and up to the sensor. This is the Z value. The value is negative because the sensor is located over the origin. c Measure the horizontal distance in parallel with the X axis from the origin to the vertical line. This is the X value. The value is negative because the sensor is located behind the origin. d Measure the horizontal distance in parallel with the Y axis from the origin to the sensor. The sensor is on the port side of the centre line while the origin is located on the starboard side. This is the Y value. The value is negative because the sensor is located on the port side of the origin. e 4 Type the values you have found for X, Y and Z into the Sensor Installation page when you install the sensor in the SY50 user interface. Measure the physical location of the motion reference unit (MRU). The motion reference unit is located next to the sonar hull unit. Both are placed on the vessel’s centre line and close to the bow. a 467020/B Draw a vertical line from the sensor and up. 199 Simrad SY50 Installation Manual b Measure the vertical distance from the waterline and down to the sensor. This is the Z value. The value is positive because the sensor is located under the origin. c Measure the horizontal distance in parallel with the X axis from the origin to the vertical line. This is the X value. The value is positive because the sensor is located in front of the origin. d Measure the horizontal distance in parallel with the Y axis from the origin to the centre line. The sensor is on the centre line, but the origin is located on the starboard side. This is the Y value. The value is negative because the sensor is located on the port side of the origin. e Type the values you have found for X, Y and Z into the Sensor Installation page when you install the sensor in the SY50 user interface. Related topics Vessel coordinate system, page 200 Placing each sensor in the vessel coordinate system, page 195 Vessel coordinate system The vessel coordinate system is established to define the relative physical locations of system units and sensors. When you have several different sensors and transducers on your vessel, and you wish each of them to provide accurate data, you need to know their relative physical positions. The antenna of a position sensor is typically mounted high above the superstructure, while a motion sensor is located close to the vessel’s centre of gravity. Both of these are physically positioned far away from the transducer, which may be located closer to the bow. Very often, the information from one sensor depends on data from an other. It is then important that the relevant measurements are compensated for these relative distances. Example If you wish to measure the actual water depth, you will need to know the vertical distance from the echo sounder transducer to the water line. Since the vessel’s displacement changes with the amount of cargo, fuel etc, the physical location of the water line on the hull must either be measured at a regular basis, or measured with a second sensor. 200 467020/B Setting to work In order to establish a system to measure the relative distance between sensors, a virtual coordinate system is established. This coordinate system uses three vectors; X, Y and Z. A The X-axis is the longitudinal direction of the vessel, and in parallel with the deck. A positive value for X means that a sensor or a reference point is located ahead of the reference point (origin). B The Y-axis is the transverse direction of the vessel, and in parallel with the deck. A positive value for Y means that a sensor or a reference point is located on the starboard side of the reference point (origin). C The Z-axis is vertical, and in parallel with the mast. A positive value for Z means that a sensor or a new reference point is located under the reference point (origin). D Reference point (Ship Origin) Coordinate system origin The origin is the common reference point where all three axis in the vessel coordinate system meet. All physical locations of the vessel’s sensors (radar and positioning system antennas, echo sounder and sonar transducers, motion reference units, etc.) are referenced to the origin. In most cases, the location of the vessel’s "official" origin has been defined by the designer or shipyard. This origin is normally identified with a physical marking, and also shown on the vessel drawings. Frequently used locations are: • Aft immediately over the rudder (frame 0) • Vessel’s centre of gravity • The physical location of the motion sensor Coordinate system alternative origins If necessary, other origin locations may be defined for specific products or purposes. One example is the Navigation Reference Point that is frequently used. Whenever a vessel is surveyed to establish accurate offset information, the surveyor may also establish an alternative origin location. Whenever relevant, any such alternative locations must be defined using offset values to the "official" origin established by the designer or shipyard. A commonly used alternative origin is the physical location of the vessel’s motion sensor. Defining the physical location of each sensor By means of the vessel coordinate system, the physical location of every sensor can be defined using three numerical values for X, Y and Z. These values must define the 467020/B 201 Simrad SY50 Installation Manual vertical and horizontal distances from a single reference point; the origin. The physical location of the motion reference unit (MRU) is often the most important sensor to define. For many systems, the vessel heading is also a critical measurement. Illustration: In this example, a second reference point has been established. It is defined with three positive offset values for X, Y and Z. All values are positive because the new reference point is in front of and below the origin, and on the starboard side. The accuracy of the three numerical values for X, Y and Z defines the accuracy of the sensor data. If you require a high accuracy, for example for underwater positioning, underwater mapping or scientific measurements, you must have each sensor positioned using professional land surveying. For such use, a good alignment survey is critical for high quality results. Surveys are normally done by qualified and trained surveyors using proven survey equipment and methods. Related topics Placing each sensor in the vessel coordinate system, page 195 202 467020/B Setting to work Inserting the installation parameters Topics Inserting the ship origin and dimensions, page 203 Inserting the installation parameters for the transducer, page 205 Inserting the installation parameters for the motion reference unit (MRU), page 208 Adjusting the built-in motion sensor offset, page 210 Adjusting the stabilization offsets for the motion sensor, page 213 Inserting the ship origin and dimensions When you have several different sensors and transducers on your vessel, and you wish each of them to provide accurate data, you need to know their relative physical positions. To do this, you must establish one or more common reference points. This reference point is also used to position the sonar echoes relative to the ship symbol on the display presentation. Prerequisites The SY50 system hardware units are installed as specified in this manual. • The SY50 system is turned on and operates normally. • The SY50 system is in Normal mode, but TX Power is set to Off to prevent transmissions. • The vessel is berthed or at sea. • Neither tools nor instruments are required. For accurate ship dimensions you need the detailed vessel drawings. Context On the Ship page you can use the ship's physical dimensions to create a virtual reference point (the Shop Origin) in a dedicated coordinate system for the SY50 system. The Ship Origin is normally located in the following position: • X position: Half the ship's length • Y position: Half the ship's width • Z position: On the waterline If you want to change the location of the Ship Origin, you can do this by providing offset values in the X, Y and/or Z directions. To do this you will need the ship drawings. 467020/B 203 Simrad SY50 Installation Manual Tip It is common practice to place the Ship Origin at the same position as the motion reference unit (MRU). This will minimize the vectors when your vessel is moving. Use the vessel drawings to establish the offset values between the basic position of the Ship Origin and the MRU location. If you do not have a motion sensor you can place the Ship Origin at any location on the vessel. We suggest that you place the origin under the captain’s seat on the bridge. All sensors will then be referenced to this position. Whenever a sonar is used with short ranges, this will provide a more precise presentation. Procedure 1 Open the Setup menu. 2 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select the small white triangle next to Installation Parameters. Observe that a menu opens with access to all the individual pages. 4 Open the Ship page. 5 Insert the physical dimensions of your vessel (length and width). Do this as accurately as possible. This information is used to create a new origin in the vessel coordinate system. 6 Offset: a If you want to keep the default reference point (origin), leave all offset values to 0 (zero). b If you want to move the reference point to another location, use the necessary offset values. To find these offset values, consult the vessel drawings. Do this as accurately as possible. 7 At the bottom of the page, select Apply to save your settings. 8 Continue your work in the Installation dialog box, or select OK to close it. Result A common reference point for the sensors and transducer has now been established. 204 467020/B Setting to work Further requirements You must proceed by defining the locations of the navigation system antenna, the motion reference sensor, and the transducer. These locations are all referenced to the same reference point. Related topics Setting to work, page 162 Inserting the installation parameters, page 203 Inserting the installation parameters for the transducer When the hull unit is placed on the trunk, the "forward" mark on the transducer shaft sleeve - and thus also "forward" on the transducer - may not point forward at all, but several degrees off the centre line. To obtain accurate echo presentations, this misalignment must be adjusted by changing the installation parameters. Prerequisites Illustration: A Bow B This is the alignment angle (±180°) C 0° transducer mark The SY50 system hardware units are installed as specified in this manual. • The SY50 system is turned on and operates normally. • The SY50 system is in Normal mode, but TX Power is set to Off to prevent transmissions. • The vessel is berthed or at sea. • Neither tools nor instruments are required. For accurate location of the transducer, you need the detailed vessel drawings. You also need the installation angles that were recorded when the transducer was installed. Context As a general recommendation, the hull unit shall be oriented with the hoisting motor pointing approximately 45 degrees of the vessel’s centre line. If this orientation makes it difficult to access electrical connections, the hull unit may be rotated during its 467020/B 205 Simrad SY50 Installation Manual installation to the most suitable direction. Independent of the hull unit orientation, the alignment is always defined as: The angle measured from the bow to the 0° transducer mark. The 0° transducer mark is located outermost on the mounting flange, and it is marked as a red "0". Depending on the transducer mounting, it can be located at any angle on the mounting flange, not necessarily as shown in the illustration. On the Transducer page, define this angle as rotation around Z. • If the 0° transducer mark points to the starboard (right) side of the vessel’s centre line, insert the alignment as a number between 0 and +180 degrees. • If the 0° transducer mark points to the port (left) side of the vessel’s centre line (as shown in the illustration), insert the alignment as a number between 0 and –180 degrees. Illustration: A Rotation around the x-axis: In the positive horizontal direction (forward), a positive rotation is clockwise. B Rotation around the y-axis: In the positive horizontal direction (starboard), a positive rotation is clockwise. C Rotation around the z-axis: In the positive vertical direction (down), a positive rotation is clockwise. D Reference point (Ship Origin) Procedure 1 Open the Setup menu. 2 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select the small white triangle next to Installation Parameters. Observe that a menu opens with access to all the individual pages. 4 Select Transducer to open the page. 5 Insert the relevant offset values. Do this as accurately as possible. 206 467020/B Setting to work a X Offset: Insert the horizontal distance on the x-axis (fore-and-aft direction) between the transducer and the Ship Origin. b Y Offset: Insert the horizontal distance on the y-axis (athwartship direction) between the transducer and the Ship Origin. c Z Offset: Insert the vertical distance on the Z axis between the transducer and the Ship Origin. 6 Obtain the rotation (angle) information from the personnel that installed the hull unit. Insert the values. Do this as accurately as possible. a Rotation Around X: Specify an angle (in degrees) to compensate for any deviation from the X axis (fore-and-aft direction) in the vessel coordinate system. If the transducer is properly installed without unintentional skew, this angle can be set to 0 degrees. b Rotation Around Y: Specify an angle (in degrees) to compensate for any deviation from the Y axis (athwartship direction) in the vessel coordinate system. If the transducer is properly installed without unintentional skew, this angle can be set to 0 degrees. c Rotation Around Z: Specify an angle (in degrees) to compensate for any deviation from the Z axis (vertical direction) in the vessel coordinate system. This is the alignment angle. • If the 0° transducer mark points to the starboard (right) side of the vessel’s centre line, insert the alignment as a number between 0 and +180 degrees. • If the 0° transducer mark points to the port (left) side of the vessel’s centre line (as shown in the illustration), insert the alignment as a number between 0 and –180 degrees. Examples: • If the alignment angle is 295 degrees, insert -65 degrees. • If the alignment angle is 15 degrees, insert 15 degrees. 7 At the bottom of the page, select Apply to save your settings. 8 Continue your work in the Installation dialog box, or select OK to close it. Related topics Setting to work, page 162 Inserting the installation parameters, page 203 467020/B 207 Simrad SY50 Installation Manual Inserting the installation parameters for the motion reference unit (MRU) The physical location of the motion reference unit (MRU) relative to the transducer is required to allow the SY50 system to adjust for roll and pitch as accurately as possible. Prerequisites The SY50 system hardware units are installed as specified in this manual. • The SY50 system is turned on and operates normally. • The SY50 system is in Normal mode, but TX Power is set to Off to prevent transmissions. • The vessel is berthed or at sea. • Neither tools nor instruments are required. The relevant offset values can normally be taken from the vessel drawings. Context The SY50 system is provided with a built-in motion sensor to provide electronic stabilization of the sonar beams. It is located inside the Power Supply Unit. The motion sensor measures the roll and pitch movements of the vessel. Note If the Power Supply Unit has been mounted with its door pointing straight aft, you do not need to enter any rotation values. If the unit faces in any other direction you must compensate for this by typing the relevant value for Rotation Around Z. For improved operational accuracy, an external motion reference unit (MRU) can be used. offsets The offset values specify the physical location of the motion reference unit relative to the reference point (origin). The relevant offset values can normally be taken from the vessel drawings. Rotation The values for rotation around the X, Y and Z axis are used to compensate for any misalignments made during the physical installation of the motion reference unit. Such misalignments occur if the sensor is not placed in parallel with the vessel’s horizontal and/or vertical planes. We strongly recommend that you install your motion reference unit so that all rotation angles can be set to 0 (zero). The required accuracy of the offset and rotation angles depends on the accuracy requirements for the echo data. 208 467020/B Setting to work Tip The motion sensor offset values are not important for sonar operation. Correct values for motion sensor rotation are important for roll and pitch compensation. Note The Kongsberg Seapath® - and other GPS systems - allow you to define the MRU location in the positioning system. If this is done, the MRU offset values in the SY50 system must be set to 0 (zero) to avoid "dual compensation". The rotation angles are normally not recorded by the positioning system. These can either be inserted into the MRU control application, or into the SY50 system. Make sure that you do not insert them both places. A Rotation around the x-axis: In the positive horizontal direction (forward), a positive rotation is clockwise. B Rotation around the y-axis: In the positive horizontal direction (starboard), a positive rotation is clockwise. C Rotation around the z-axis: In the positive vertical direction (down), a positive rotation is clockwise. D Reference point (Ship Origin) Procedure 1 Open the Setup menu. 2 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select the small white triangle next to Installation Parameters. Observe that a menu opens with access to all the individual pages. 4 Select MRU to open the page. 5 From the vessel drawings, extract the relevant offset information, and insert those values. Do this as accurately as possible. 467020/B 209 Simrad SY50 Installation Manual Note The Kongsberg Seapath® - and other GPS systems - allow you to define the MRU location in the positioning system. If this is done, the MRU offset values in the SY50 system must be set to 0 (zero) to avoid "dual compensation". The rotation angles are normally not recorded by the positioning system. These can either be inserted into the MRU control application, or into the SY50 system. Make sure that you do not insert them both places. 6 From the information provided by the personnel installing the motion sensor, obtain the relevant rotation information. Insert the values. Do this as accurately as possible. 7 At the bottom of the page, select Apply to save your settings. 8 Continue your work in the Installation dialog box, or select OK to close it. Related topics Setting to work, page 162 Inserting the installation parameters, page 203 Adjusting the built-in motion sensor offset, page 210 Adjusting the stabilization offsets for the motion sensor, page 213 Adjusting the built-in motion sensor offset The information from a motion reference unit (MRU) (normally heave, roll and pitch information) is imported into the SY50 system to increase the accuracy of the echo data. The SY50 system is provided with a built-in motion sensor to provide electronic stabilization of the sonar beams. It is located inside the Power Supply Unit. Prerequisites The SY50 system hardware units are installed as specified in this manual. • The SY50 system is turned on and operates normally. • The SY50 system is in Normal mode, but TX Power is set to Off to prevent transmissions. • The vessel is berthed or at sea. • Neither tools nor instruments are required. Context The Power Supply Unit is mounted on the bulkhead close to the hull unit. The purpose of the Power Supply Unit is to provide the hull unit with the necessary power for operation. The Power Supply Unit further contains the logic circuitry required to control the lower and hoist operation, as well as a small motion sensor. 210 467020/B Setting to work If the Power Supply Unit has been mounted with its door pointing straight aft, you do not need to enter any rotation values. If the unit faces in any other direction you must compensate for this by typing the relevant value for Rotation Around Z. Independent of the power supply orientation, the offset of the built-in motion sensor is always defined as: The angle measured from the bow to the motion sensor’s 0° reference. On the MRU page, define the offset as rotation around Z. Rotation Around Z: A Unit facing forward: ±180 degrees B Unit facing port: +90 degrees C Unit facing aft: 0 degrees D Unit facing starboard: -90 degrees Note Do not confuse stabilization offset with installation offset. The installation offset values describe the physical location and orientation of an item, and how this location is related to the vessel's coordinate system. The stabilization offset values describe any misalignments related to the measurements a sensor make. 467020/B 211 Simrad SY50 Installation Manual Illustration: A Rotation around the x-axis: In the positive horizontal direction (forward), a positive rotation is clockwise. B Rotation around the y-axis: In the positive horizontal direction (starboard), a positive rotation is clockwise. C Rotation around the z-axis: In the positive vertical direction (down), a positive rotation is clockwise. D Reference point (Ship Origin) Procedure 1 Estimate the alignment angle from the bow (vessel’s centre line) to the 0° reference mark for the built-in motion sensor. Do this as accurately as possible. 2 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select the small white triangle next to Installation Parameters. Observe that a menu opens with access to all the individual pages. 4 Select MRU to open the page. 5 Insert the alignment offset angle as a rotation around Z. • If the 0° reference mark for the built-in motion sensor points to the starboard (right) side of the vessel’s centre line (as shown in the illustration), insert the offset as a number between 0 and +180 degrees. • If the 0° reference mark points to the port (left) side of the vessel’s centre line, insert the offset as a number between 0 and –180 degrees. 6 At the bottom of the page, select Apply to save your settings. 7 Continue your work in the Installation dialog box, or select OK to close it. 212 467020/B Setting to work Related topics Setting to work, page 162 Inserting the installation parameters, page 203 Inserting the installation parameters for the motion reference unit (MRU), page 208 Adjusting the stabilization offsets for the motion sensor, page 213 Adjusting the stabilization offsets for the motion sensor The SY50 system is provided with a built-in motion sensor to provide electronic stabilization of the sonar beams. It is located inside the Power Supply Unit. It is very important that the motion sensor is set correctly with stabilization offset values that are adapted to the physical installation angles of the hull unit. To align an external motion sensor to the internal sensor, you may need to adjust the stabilization offset values. Prerequisites Note Before you do this task you must adjust the installation offset of the motion sensor. The SY50 system hardware units are installed as specified in this manual. • The external motion sensor is connected to the SY50 system. • The MRC application is installed on the Processor Unit. • The SY50 system is turned on and operates normally. • The vessel is berthed. The following tool is required: • Digital level Note We recommend that you do this task in calm sea without any vessel movements. Context It is very important that the motion sensor is set correctly with stabilization offset values that are adapted to the physical installation angles of the hull unit. Even a small offset error can give you very inccurate readings. The internal motion sensor is located inside the Power Supply Unit. Because of this, the risk of stabilization offset misalignment is present. The two screen captures below illustrate how the SY50 system can provide inaccurate data if the stabilization offset is misaligned. In both examples, the tilt is set to approximately 24 degrees, and you are looking at the echoes from a flat bottom at a very short range. The first example is made without any offset errors, and the echoes from the bottom are evenly distributed in the circle. On the second screen capture, a 3 467020/B 213 Simrad SY50 Installation Manual degrees roll offset error causes the echoes to be "distorted". This error will of course be more visible on longer ranges. Note Do not confuse stabilization offset with installation offset. The installation offset values describe the physical location and orientation of an item, and how this location is related to the vessel's coordinate system. The stabilization offset values describe any misalignments related to the measurements a sensor make. Procedure 1 Select a very short range. 2 Make sure that the installation parameters for the internal motion sensor (offset and rotation offsets) are correct. 3 Open the Display menu. a 214 Select Display Options. 467020/B Setting to work 4 5 b Select General to open the page. c In the Top Bar list, enable Roll and Pitch. d On the top bar, read the roll and pitch values. e Write down the values. f Select OK to save the selected settings and close the dialog box. Place the digital level on the mounting flange. a Measure the roll and pitch angles. b Write down the values. c Compare the measured values with the values provided on the top bar. Adjustments are required if the measured values do not match. If necessary: Adjust the stabilization offsets. a Open the Setup menu. b Open the Stabilization function. c Adjust the Roll Offset and Pitch Offset settings. Select [—] on the left side to decrease the value, or select [+] on the right side to increase. For improved operational accuracy, an external motion reference unit (MRU) can be used. To align an external motion sensor to the internal sensor, you may need to adjust the stabilization offset values. The external motion sensor is connected to the SY50 system. 6 Make sure that the installation parameters for the external motion sensor (offset and rotation offsets) are correct. 7 Open the Setup menu. a On the Setup menu, select Installation. b On the left side of the Installation dialog box, select Motion Reference Unit. c Select COMx to connect to the external motion sensor. ("COMx" is the serial port to which the motion sensor is connected.) 467020/B 215 Simrad SY50 Installation Manual 8 d Select which NMEA sentence (datagram) you want to use. e Select the baud rate. f Select Apply and then Close to save your choice and close the Installation dialog box. On the top bar, read the roll and pitch values. a Compare the new pitch and roll values with the values from the internal motion sensor. b If necessary: Adjust the stabilization offsets. Related topics Setting to work, page 162 Inserting the installation parameters, page 203 Inserting the installation parameters for the motion reference unit (MRU), page 208 Adjusting the built-in motion sensor offset, page 210 216 467020/B Setting to work Setting up the interfaces to peripheral devices Topics Installing navigation sensors and other sensors, page 217 Defining the serial and Ethernet (LAN) port parameters, page 219 Setting up the input from a navigation system (GPS), page 220 Setting up the interface for speed log input, page 223 Setting up the interface for course gyro input, page 225 Configuring the sensor interface, page 227 Setting up the input from a motion reference unit (MRU), page 229 Setting up the SY50 system for synchronized operation, page 231 Setting up input from buoys, fish aggregating devices and other external objects, page 234 Installing navigation sensors and other sensors For the SY50 system to use and offer correct navigational information, one or more external sensors must be connected. Typical sensors are those providing navigational information (heading, speed or geographical position). To set up the communication parameters on the serial and LAN ports, use the I/O Setup page. To select which sensors to install, use the Sensor Installation page. The Sensor Configuration page allows you to define a datagram priority, so that the information from the "most reliable" sensor is used by the SY50 system. You can also define manual values in case a sensor is unserviceable, or not installed. Prerequisites The new sensor is physically connected to the SY50 system using a serial or network cable. Context The Sensor Installation page allows your SY50 system to communicate with external sensors and systems. However, in order to communicate with each sensor, you must first set up the relevant communication parameters. Once the communication has been established and the sensor is connected, you must define the datagram priority and finalize the configuration. 467020/B 217 Simrad SY50 Installation Manual Note Just making changes and selecting OK at the bottom of the page will not install anything. Select what to install, define the relevant parameters, and then select Add. Procedure 1 Open the Setup menu. 2 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 3 Set up the interfaces to the navigation sensors. a On the left side of the Installation dialog box, select I/O Setup. b Set up the relevant serial or Ethernet (LAN) communication parameters. c At the bottom of the page, select Apply to save your settings. d On the left side of the Installation dialog box, select Sensor Installation. e Select the type of sensor you want to interface, and define the relevant parameters. f Select Add to save the new sensor interface you have defined. g On the left side of the Installation dialog box, select Sensor Configuration. h Define the priority of the datagrams, and set up relevant configuration parameters. i At the bottom of the page, select Apply to save your settings. 4 Repeat for each sensor interface that you need to set up. 5 Continue your work in the Installation dialog box, or select OK to close it. Related topics Setting to work, page 162 Setting up the interfaces to peripheral devices, page 217 218 467020/B Setting to work Defining the serial and Ethernet (LAN) port parameters For any sensor interface to work, the communication parameters must be set up correctly. The SY50 software automatically scans the Processor Unit to locate and identify the available communication ports. Once the software has established a list of valid interfaces, you can set up and control the communication parameters. Prerequisites This procedure assumes that: • You have a vacant interface port on your Processor Unit. • You are familiar with NMEA and other relevant datagram formats. • You know how to set up the parameters for serial and local area network (LAN) communication. • The relevant communication parameters required for the sensor interface are known. Context The I/O Setup page provides two lists; one for serial ports and one for Ethernet (LAN) ports. Each list is supported with a set of functions to set up and monitor the communication ports. Select the port you want to work with and then select one of the buttons below the list. Tip The Sensors page in the Diagnostics dialog box provides an overview of all the communication lines and sensors in use. All relevant status information is provided. Open the Diagnostics dialog box from the Setup menu. When you work in the Installation dialog box, you must always select Apply to save the changes made on a page. You must do this before you continue working on a different page. Procedure 1 Open the Setup menu. 2 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select I/O Setup. 4 Observe that the available serial interface ports on the Processor Unit are listed. 5 Set up the relevant serial or Ethernet (LAN) communication parameters. a Select the interface port you want to set up. b Select Setup to open the Serial Port Setup or LAN Port Setup dialog box. 467020/B 219 Simrad SY50 Installation Manual c Set up the relevant serial or Ethernet (LAN) communication parameters. The communication parameters defined for NMEA 0183 are: • Baud rate: 4800 bit/s • Data bits: 8 • Parity: Even • Stop bits: 1 Some instruments may provide other parameters and/or options. You must always check the relevant technical documentation supplied by the manufacturer. d Select OK to save the selected settings and close the dialog box. 6 At the bottom of the page, select Apply to save your settings. 7 Repeat for any other communication ports that you need to set up. 8 Continue your work in the Installation dialog box, or select OK to close it. Related topics Setting to work, page 162 Setting up the interfaces to peripheral devices, page 217 Setting up the input from a navigation system (GPS) For the SY50 system to use and offer correct navigational information, one or more external sensors must be connected. Typical sensors are those providing navigational information (heading, speed or geographical position). To select which sensors to install, use the Sensor Installation page. Your current position is shown on the top bar if you have enabled this in the Display Options dialog box. Prerequisites This procedure assumes that: • You have a vacant interface port on your Processor Unit. • You are familiar with NMEA and other relevant datagram formats. • You know how to set up the parameters for serial and local area network (LAN) communication. • The interface port is set up with the correct communication parameters. • The SY50 system is turned on and operates normally. • The new sensor is physically connected to the SY50 system using a serial or network cable. The sensor is turned on and in normal operation. Neither tools nor instruments are required. 220 467020/B Setting to work Context The Sensor Installation page allows your SY50 system to communicate with external sensors and systems. You must specify which communication port to use (LAN (Local Area Network) or serial port). You can type a custom name to identify the sensor import. In the list of valid datagram formats, select the format(s) to be accepted by the SY50 system. For each relevant sensor you must insert the offset values that define the its physical location relative to the vessel’s coordinate system. Note Just making changes and selecting OK at the bottom of the page will not install anything. Select what to install, define the relevant parameters, and then select Add. Procedure 1 Connect the navigation system to an available communication port on your computer. This is described in the Cable layout and interconnections chapter. Observe the applicable requirements related to cabling. Make sure that the total length of the serial line cable does not exceed approximately 50 meters. If a longer cable is required, you may need to use buffer amplifiers. If the computer is not fitted with a suitable serial line connector, use a USB-to-serial converter. Several types are commercially available. Note that most USB-to-serial converters will introduce some latency. They may also introduce be jitter in the communication. The amount of jitter depends on the quality of the converter. 2 Open the Setup menu. 3 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 4 On the left side of the Installation dialog box, select Sensor Installation. 5 For Type, select the GPS sensor to import information from a global positioning system. 6 Select which port you want to import the sensor information on. 7 If you want to check the communication parameters, select Inspect Port. Note You cannot make any changes here. To change the communication parameters, use the I/O Setup page. 467020/B 221 Simrad SY50 Installation Manual 8 If you want to check that the peripheral system is transmitting data to the SY50 system, select Monitor. The Port Monitor dialog box provides one text box for incoming messages (Rx Data), and one for outgoing messages (Tx Data). Use these boxes and your knowledge of the data communication to investigate the datagrams. The Port Monitor dialog box is a tool for debugging purposes. It is neither required nor intended for normal operation of the SY50 system. 9 Type a custom name to identify the interface in other dialog boxes. 10 Select which datagram(s) you want to import from the sensor. 11 If relevant, specify a dedicated talker ID. 12 Provide the accurate physical location of the sensor (or its antenna) with reference to the vessel’s coordinate system. The position of certain sensors must be defined as an offset to the Ship Origin in the coordinate system to maximize performance. These offset values are all required to allow the SY50 system to give you as accurate information as possible. The degree of accuracy offered by the SY50 system is directly related to the accuracy of the information you enter on the Sensor Installation page. 13 a Select the offset value on the X axis (fore-and-aft direction) from the Ship Origin. Adjust with a positive value for X if the sensor is located ahead of the ship origin. b Select the offset value on the Y axis (athwartship) from the Ship Origin. Adjust with a positive value for Y if the sensor is located on the starboard side of the ship origin. c Select the offset value on the Z axis (vertical) from the Ship Origin. Adjust with a positive value for Z if the sensor is located under the ship origin. Select Add to save the new sensor interface you have defined. The sensor interface is added to the Installed Sensors list on the Sensor Installation page. 14 At the bottom of the dialog box, select Apply to save your settings. 15 Repeat for each sensor interface that you need to set up. 16 Continue your work in the Installation dialog box, or select OK to close it. Further requirements On the left side of the Installation dialog box, select Sensor Configuration. Define the priority of the datagrams, and set up relevant configuration parameters. Related topics Setting to work, page 162 Setting up the interfaces to peripheral devices, page 217 222 467020/B Setting to work Setting up the interface for speed log input In order to operate correctly, the SY50 system requires input from a speed log. In most cases a suitable sensor is already installed on the vessel. A global positioning system (GPS) with a compatible output format can also be used. To select which sensors to install, use the Sensor Installation page. The vessel speed is shown on the top bar if you have enabled this in the Display Options dialog box. Prerequisites This procedure assumes that: • You have a vacant interface port on your Processor Unit. • You are familiar with NMEA and other relevant datagram formats. • You know how to set up the parameters for serial and local area network (LAN) communication. • The interface port is set up with the correct communication parameters. • The SY50 system is turned on and operates normally. • The new sensor is physically connected to the SY50 system using a serial or network cable. The sensor is turned on and in normal operation. Neither tools nor instruments are required. Context Note The input from a speed log is essential for operation. Without speed information, the SY50 system will neither be able to present correct navigational information, nor compensate for vessel movements. This lack of compensation will prevent the system from providing correct echo information. The Sensor Installation page allows your SY50 system to communicate with external sensors and systems. You must specify which communication port to use (LAN (Local Area Network) or serial port). You can type a custom name to identify the sensor import. In the list of valid datagram formats, select the format(s) to be accepted by the SY50 system. Note Just making changes and selecting OK at the bottom of the page will not install anything. Select what to install, define the relevant parameters, and then select Add. 467020/B 223 Simrad SY50 Installation Manual Procedure 1 Connect the speed log to an available communication port on your computer. This is described in the Cable layout and interconnections chapter. Observe the applicable requirements related to cabling. Make sure that the total length of the serial line cable does not exceed approximately 50 meters. If a longer cable is required, you may need to use buffer amplifiers. If the computer is not fitted with a suitable serial line connector, use a USB-to-serial converter. Several types are commercially available. Note that most USB-to-serial converters will introduce some latency. They may also introduce be jitter in the communication. The amount of jitter depends on the quality of the converter. 2 Open the Setup menu. 3 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 4 On the left side of the Installation dialog box, select Sensor Installation. 5 For Sensor Type, select Speed Log to import information from a global positioning system. 6 Select which port you want to import the sensor information on. 7 If you want to check the communication parameters, select Inspect Port. Note You cannot make any changes here. To change the communication parameters, use the I/O Setup page. 8 If you want to check that the peripheral system is transmitting data to the SY50 system, select Monitor. The Port Monitor dialog box provides one text box for incoming messages (Rx Data), and one for outgoing messages (Tx Data). Use these boxes and your knowledge of the data communication to investigate the datagrams. The Port Monitor dialog box is a tool for debugging purposes. It is neither required nor intended for normal operation of the SY50 system. 9 Type a custom name to identify the interface in other dialog boxes. 10 Select which datagram(s) you want to import from the sensor. 11 If relevant, specify a dedicated talker ID. 12 Select Add to save the new sensor interface you have defined. The sensor interface is added to the Installed Sensors list on the Sensor Installation page. 13 224 At the bottom of the dialog box, select Apply to save your settings. 467020/B Setting to work 14 Continue your work in the Installation dialog box, or select OK to close it. Further requirements On the left side of the Installation dialog box, select Sensor Configuration. Define the priority of the datagrams, and set up relevant configuration parameters. Related topics Setting to work, page 162 Setting up the interfaces to peripheral devices, page 217 Setting up the interface for course gyro input In order to operate correctly, the SY50 system requires input from a course gyro. In most cases a suitable course gyro is already installed on the vessel. A global positioning system (GPS) with a compatible output format can also be used. To select which sensors to install, use the Sensor Installation page. The current heading is shown on the top bar if you have enabled this in the Display Options dialog box. Prerequisites This procedure assumes that: • You have a vacant interface port on your Processor Unit. • You are familiar with NMEA and other relevant datagram formats. • You know how to set up the parameters for serial and local area network (LAN) communication. • The interface port is set up with the correct communication parameters. • The SY50 system is turned on and operates normally. • The new sensor is physically connected to the SY50 system using a serial or network cable. The sensor is turned on and in normal operation. Neither tools nor instruments are required. Context Note The input from a course gyro is essential for operation. Without the input from a course gyro, the SY50 system will not be able to present correct navigational information. This lack of compensation will prevent the system from providing correct echo information. The Sensor Installation page allows your SY50 system to communicate with external sensors and systems. You must specify which communication port to use (LAN (Local Area Network) or serial port). You can type a custom name to identify the sensor import. In the list of valid datagram formats, select the format(s) to be accepted by the SY50 467020/B 225 Simrad SY50 Installation Manual system. For each relevant sensor you must insert the offset values that define the its physical location relative to the vessel’s coordinate system. Note Just making changes and selecting OK at the bottom of the page will not install anything. Select what to install, define the relevant parameters, and then select Add. Procedure 1 Connect the gyro (or other heading sensor) to an available communication port on your computer. This is described in the Cable layout and interconnections chapter. Observe the applicable requirements related to cabling. Make sure that the total length of the serial line cable does not exceed approximately 50 meters. If a longer cable is required, you may need to use buffer amplifiers. If the computer is not fitted with a suitable serial line connector, use a USB-to-serial converter. Several types are commercially available. Note that most USB-to-serial converters will introduce some latency. They may also introduce be jitter in the communication. The amount of jitter depends on the quality of the converter. 2 Open the Setup menu. 3 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 4 On the left side of the Installation dialog box, select Sensor Installation. 5 For Sensor Type, select Gyro to import information from a global positioning system. 6 Select which port you want to import the sensor information on. 7 If you want to check the communication parameters, select Inspect Port. Note You cannot make any changes here. To change the communication parameters, use the I/O Setup page. 8 If you want to check that the peripheral system is transmitting data to the SY50 system, select Monitor. The Port Monitor dialog box provides one text box for incoming messages (Rx Data), and one for outgoing messages (Tx Data). Use these boxes and your knowledge of the data communication to investigate the datagrams. The Port Monitor dialog box is a tool for debugging purposes. It is neither required nor intended for normal operation of the SY50 system. 9 226 Type a custom name to identify the interface in other dialog boxes. 467020/B Setting to work 10 Select which datagram(s) you want to import from the sensor. 11 If relevant, specify a dedicated talker ID. 12 Provide the accurate physical location of the sensor (or its antenna) with reference to the vessel’s coordinate system. The position of certain sensors must be defined as an offset to the Ship Origin in the coordinate system to maximize performance. These offset values are all required to allow the SY50 system to give you as accurate information as possible. The degree of accuracy offered by the SY50 system is directly related to the accuracy of the information you enter on the Sensor Installation page. 13 a Select the offset value on the X axis (fore-and-aft direction) from the Ship Origin. Adjust with a positive value for X if the sensor is located ahead of the ship origin. b Select the offset value on the Y axis (athwartship) from the Ship Origin. Adjust with a positive value for Y if the sensor is located on the starboard side of the ship origin. c Select the offset value on the Z axis (vertical) from the Ship Origin. Adjust with a positive value for Z if the sensor is located under the ship origin. Select Add to save the new sensor interface you have defined. The sensor interface is added to the Installed Sensors list on the Sensor Installation page. 14 At the bottom of the dialog box, select Apply to save your settings. 15 Continue your work in the Installation dialog box, or select OK to close it. Further requirements On the left side of the Installation dialog box, select Sensor Configuration. Define the priority of the datagrams, and set up relevant configuration parameters. Related topics Setting to work, page 162 Setting up the interfaces to peripheral devices, page 217 Configuring the sensor interface With multiple sensors connected to the SY50 system, many of them will provide the same datagrams. We cannot expect that these datagrams provide the same information. The Sensor Configuration page allows you to define a datagram priority, so that the information from the "most reliable" sensor is used by the SY50 system. You can also define manual values in case a sensor is unserviceable, or not installed. Prerequisites This procedure assumes that: 467020/B 227 Simrad SY50 Installation Manual • The new sensor is physically connected to the SY50 system using a serial or network cable. • The interface port is set up with the correct communication parameters. • The input from the navigation sensor is defined in the user interface. The relevant interface parameters and physical location properties for the sensor are defined. Context Any information in a datagram, for example the current depth, may be provided in different datagrams from several sensors. Due to a number of reasons (environmental conditions, installation, configuration, accuracy, etc.), the numerical values provided can be different from one sensor to another. Several sensor are provided on the Sensor Configuration page, one for each type of information. Select the sensor you wish to configure in the Sensor list. For each type, you can define a priority sensor by rearranging the datagrams in a list. You can also define manual values in case a sensor is unserviceable, or not installed. The SY50 system can communicate with several different sensor types. Use the Sensor Installation page to define which external sensors your SY50 system will import information from. You must also specify which datagram formats to use. Note When you work in the Installation dialog box, you must always select Apply to save the changes made on a page. You must do this before you continue working on a different page. Procedure 1 Open the Setup menu. 2 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select Sensor Configuration. Observe that the Sensor Configuration page opens. 4 Select the sensor you wish to configure in the Sensor list. 5 If you wish to use the built-in datagram priority, select Auto. • With Auto enabled, the priority list is used. Information is imported from the sensor at the top of the list. If the sensor fails to provide information for more than 20 seconds, data from the next sensor is used. • With Auto disabled, the priority list is not used. Information is imported from the sensor at the top of the list. All other sensors are ignored. 228 467020/B Setting to work 6 If you wish to control the datagram priority manually, do not select Auto. To change the priority for a given datagram, select it, and change its location on the list using the arrow buttons. 7 If relevant, add a manual value for the sensor input. 8 At the bottom of the dialog box, select Apply to save your settings. 9 Repeat for each sensor interface that you need to set up. 10 Continue your work in the Installation dialog box, or select OK to close it. Related topics Setting to work, page 162 Setting up the interfaces to peripheral devices, page 217 Setting up the input from a motion reference unit (MRU) The information from a motion reference unit (MRU) (normally heave, roll and pitch information) is imported into the SY50 system to increase the accuracy of the echo data. The SY50 system is provided with a built-in motion sensor to provide electronic stabilization of the sonar beams. It is located inside the Power Supply Unit. For improved operational accuracy, an external motion reference unit (MRU) can be used. This task is only applicable is you are using an external motion reference unit on your SY50 system. Prerequisites This procedure assumes that: • You have a vacant interface port on your Processor Unit. • You are familiar with NMEA and other relevant datagram formats. • You know how to set up the parameters for serial and local area network (LAN) communication. • The interface port is set up with the correct communication parameters. • The SY50 system is turned on and operates normally. • The new sensor is physically connected to the SY50 system using a serial or network cable. The sensor is turned on and in normal operation. Neither tools nor instruments are required. Context The motion reference unit (MRU) measures the roll and pitch movements of the vessel. Some sensor models also measure heave. The information provided by the motion sensor is used by the SY50 system to stabilize the beams. 467020/B 229 Simrad SY50 Installation Manual Note This task is only applicable is you are using an external motion reference unit on your SY50 system. Procedure 1 Connect the motion sensor system to an available communication port on your computer. This is described in the Cable layout and interconnections chapter. Observe the applicable requirements related to cabling. Make sure that the total length of the serial line cable does not exceed approximately 50 meters. If a longer cable is required, you may need to use buffer amplifiers. If the computer is not fitted with a suitable serial line connector, use a USB-to-serial converter. Several types are commercially available. Note that most USB-to-serial converters will introduce some latency. They may also introduce be jitter in the communication. The amount of jitter depends on the quality of the converter. 2 Open the Setup menu. 3 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. Note If you want to use a serial line to interface the motion sensor, and no COM ports are available, you must first release a port on the I/O Setup page. If you choose a serial COM port to interface the motion sensor, make sure that you do not put the same COM port to other use on the I/O Setup page. 4 Release an unused serial port (COM) port. a On the left side of the Installation dialog box, select I/O Setup. b Observe that the available serial interface ports on the Processor Unit are listed. c If you have a vacant COM port, select it, then select Remove to delete it from the list. d At the bottom of the page, select Apply to save your settings. e Close the Installation dialog box. f Restart the SY50 system. Restarting allows the Processor Unit to "free" the port. 230 467020/B Setting to work g When the SY50 system has started, proceed to the Motion Reference Unit page to put the communication port to use. 5 On the left side of the Installation dialog box, select Motion Reference Unit. 6 Set up the interface. If you select to use the LAN port, the SY50 system will automatically use the built-in motion sensor. Select COMx to connect to the external motion sensor. "COMx" is the serial port to which the motion sensor is connected. Select None to disconnect the SY50 system from both external and internal motion sensors. a Select the Ethernet port or serial port you want to use. b Select which protocol (datagram sentence) you want to use. c If you are using a serial line, define the baud rate. 7 At the bottom of the dialog box, select Apply to save your settings. 8 Continue your work in the Installation dialog box, or select OK to close it. Further requirements If you choose a serial COM port to interface the motion sensor, make sure that you do not put the same COM port to other use on the I/O Setup page. Note To align an external motion sensor to the internal sensor, you may need to adjust the stabilization offset values. Related topics Setting to work, page 162 Setting up the interfaces to peripheral devices, page 217 Adjusting the stabilization offsets for the motion sensor, page 213 Setting up the SY50 system for synchronized operation If you want to use the SY50 system as a master or slave in a synchronized system, you must set it up for such operation. To do this, you must select which communication port to use for the synchronization interface, and you must select the requested synchronization mode. Prerequisites This procedure assumes that: • The vessel is berthed or at sea. • You have an RS2-232 interface port on your computer that allows you to use the CTS/RTS connections. For "slave" operation, a remote system (for example K-Sync or Simrad TU40) must be available to provide trigger pulses. For "master" operation, a remote hydroacoustic 467020/B 231 Simrad SY50 Installation Manual system (sonar, echo sounder) is connected. This remote system must be set up in "slave" mode. You must be equipped with a standard set of tools. This tool set must comprise the normal tools for electronic and electromechanical tasks. This includes different screwdriver types, pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in various sizes. We recommend that all tools are demagnetized to protect your equipment. Context Whenever more than one hydroacoustic system is installed on a vessel, interference may occur. To avoid interference, you have these options: • The systems are all connected to a common synchronization system. • One of the acoustic systems is set up as "master", and controls the transmissions on the other systems. The SY50 system offers functionality for remote transmit synchronization. It can be set up to operate in either Master or Slave mode. Note When you work in the Installation dialog box, you must always select Apply to save the changes made on a page. You must do this before you continue working on a different page. Procedure 1 Connect the synchronization cable from the remote system to an available communication port on your computer. This is described in the Cable layout and interconnections chapter. Observe the applicable requirements related to cabling. Make sure that the total length of the serial line cable does not exceed approximately 50 meters. If a longer cable is required, you may need to use buffer amplifiers. If the computer is not fitted with a suitable serial line connector, use a USB-to-serial converter. Several types are commercially available. Note that most USB-to-serial converters will introduce some latency. They may also introduce be jitter in the communication. The amount of jitter depends on the quality of the converter. A Local connection on the computer B Connection on remote device 232 467020/B Setting to work 2 Turn on the SY50 system and set it to normal use. 3 Open the Setup menu. 4 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 5 On the left side of the Installation dialog box, select Synchronization. 6 Select Synchronization Mode. • Stand-alone This synchronization mode is used when the SY50 system is working by itself. Synchronization is turned off. It is the default setting. The SY50 system operates using the current settings for ping interval. The operation is independent of any trigger signals arriving at the synchronization port. The Synchronization Delay setting is not applicable when synchronization is switched off. • Master Master mode is used if the SY50 system shall operate as the controlling unit in a synchronized system. Any peripheral hydroacoustic system(s) are only permitted to transmit when enabled by the SY50 system. The SY50 system operates using the current settings for ping interval. It also sends trigger signals to the peripheral system(s). This mode is unavailable if you set Synchronization Port to Transceiver Auxiliary Port. • Slave The Slave mode is used if the SY50 system shall transmit only when permitted by a peripheral system. When the Slave mode is selected, the SY50 system will not transmit ("ping") unless an external trigger appears on the chosen synchronization port. The peripheral system may be any other hydroacoustic product (for example an echo sounder or sonar), or even a dedicated synchronization system. 7 Select Synchronization Delay. This delay parameter is used differently depending on the chosen synchronization mode. • Stand-alone The Synchronization Delay setting is not applicable when synchronization is switched off. • Master In Master mode, the SY50 system waits for the delay time after the external trigger signal has been sent to the slaves before transmitting the ping. This is often referred to as a pre-trigger. 467020/B 233 Simrad SY50 Installation Manual Note This delay will only work when the synchronization is set up using a serial port. • Slave In Slave mode, the SY50 system waits for the delay time after the external trigger signal has arrived before transmitting the ping. This is often referred to as a post-trigger. 8 From the list of ports available, select Synchronization Port. This is the interface port currently used to transmit or receive synchronization signals. It must be an RS-232 serial port. Since the synchronization function only uses the Request To Send (RTS) and Clear To Send (CTS) signals on a serial port, you may be able to use a port that is already assigned other interface purposes. For the same reason, you do not need to define any baud rate. 9 At the bottom of the page, select Apply to save your settings. 10 Continue your work in the Installation dialog box, or select OK to close it. Related topics Setting to work, page 162 Setting up the interfaces to peripheral devices, page 217 Setting up input from buoys, fish aggregating devices and other external objects Position information from external objects such as buoys, fish aggregating devices and other similar items can be imported into the SY50 system. Prerequisites This procedure assumes that: • You have a vacant interface port on your Processor Unit. • A suitable receiver system must be available. • You are familiar with NMEA and other relevant datagram formats. • You know how to set up the parameters for serial and local area network (LAN) communication. • The interface port is set up with the correct communication parameters. • The SY50 system is turned on and operates normally. Context The Sensor Installation page allows your SY50 system to communicate with external sensors and systems. You must specify which communication port to use (LAN (Local Area Network) or serial port). You can type a custom name to identify the sensor import. 234 467020/B Setting to work In the list of valid datagram formats, select the format(s) to be accepted by the SY50 system. For each relevant sensor you must insert the offset values that define the its physical location relative to the vessel’s coordinate system. Note Just making changes and selecting OK at the bottom of the page will not install anything. Select what to install, define the relevant parameters, and then select Add. Procedure 1 Connect the receiver to an available communication port on the Processor Unit. This is described in the Cable layout and interconnections chapter. Observe the applicable requirements related to cabling. Make sure that the total length of the serial line cable does not exceed approximately 50 meters. If a longer cable is required, you may need to use buffer amplifiers. If the computer is not fitted with a suitable serial line connector, use a USB-to-serial converter. Several types are commercially available. Note that most USB-to-serial converters will introduce some latency. They may also introduce be jitter in the communication. The amount of jitter depends on the quality of the converter. 2 Open the Setup menu. 3 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 4 On the left side of the Installation dialog box, select Sensor Installation. 5 For Type, select External Objects to import information from relevant devices. 6 Select which port you want to import the sensor information on. 7 If you want to check the communication parameters, select Inspect Port. Note You cannot make any changes here. To change the communication parameters, use the I/O Setup page. 8 If you want to check that the peripheral system is transmitting data to the SY50 system, select Monitor. The Port Monitor dialog box provides one text box for incoming messages (Rx Data), and one for outgoing messages (Tx Data). Use these boxes and your knowledge of the data communication to investigate the datagrams. The Port Monitor dialog box is a tool for debugging purposes. It is neither required nor intended for normal operation of the SY50 system. 9 Type a custom name to identify the interface in other dialog boxes. 467020/B 235 Simrad SY50 Installation Manual 10 Select which datagram(s) you want to import from the sensor. 11 If relevant, specify a dedicated talker ID. 12 Select Add to save the new sensor interface you have defined. The sensor interface is added to the Installed Sensors list on the Sensor Installation page. 13 At the bottom of the dialog box, select Apply to save your settings. 14 Continue your work in the Installation dialog box, or select OK to close it. Further requirements On the left side of the Installation dialog box, select Sensor Configuration. Define the priority of the datagrams, and set up relevant configuration parameters. Related topics Setting to work, page 162 Setting up the interfaces to peripheral devices, page 217 236 467020/B Setting to work Configuring the SY50 system for normal operation Topics Selecting measurement units, page 237 Setting up the alarm limits for system protection, page 238 Configuring the SY50 system for data recording, page 240 Configuring the environmental parameters, page 241 Selecting the language displayed in the menus and dialog boxes, page 242 Saving the current user settings, page 242 Selecting measurement units The SY50 system is prepared to work with several international standards for units of measurements. From the Units page you control which units of measurements that are used. Context The user interface presents many measurements. These measurements are for example related to depth, range and distance. Use the Units options to select the units of measurements you want to work with. The SY50 system uses them in all presentations. You only need to define them once. Note When you work in the Installation dialog box, you must always select Apply to save the changes made on a page. You must do this before you continue working on a different page. Procedure 1 Open the Setup menu. 2 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select Units. 4 Adjust the settings to fit your requirements. 467020/B 237 Simrad SY50 Installation Manual 5 At the bottom of the page, select Apply to save your settings. 6 Continue your work in the Installation dialog box, or select OK to close it. Related topics Configuring the SY50 system for normal operation, page 237 Setting up the alarm limits for system protection Safe operation of the SY50 system is made possible using multiple sensors that monitor the operation and the performance. Whenever a suspicious event takes place, a relevant message, warning or alarm is provided. Selected alarm limits may be adjusted to fit your operational requirements. Context The System Protection page allows you to specify alarm limits for the hull unit and the transducer. Additional system protection features are also listed. These function are automatically monitored by the software in the SY50 system. You are not permitted to change the alarm limits. If an alarm limit is exceeded a relevant message is issued by the SY50 system. At the same time, the relevant descriptive text is provided with a dark background. Procedure 1 Open the Setup menu. 2 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select System Protection to open the page. 4 Define the relevant parameters. Transducer Tx Inhibit Hull Unit Position If the transducer is activated when out of the water it may be damaged beyond repair. With the transducer fully retracted, no transmissions ("pings") take place. When you lower the transducer into the water, you can specify a vertical position for when the transmissions start. When 238 467020/B Setting to work the transducer is retracted, transmissions will stop when the transducer reaches the same position. This functionality is only available if a hull unit has been activated in the user interface. Tx Inhibit Operation Mode This feature activates the system protection to make sure that the SY50 system does not transmit ("ping") when you have chosen Replay or Inactive mode. Hull Unit You must specify a maximum speed for the vessel. This speed can match the hull unit specification, or you can choose a lower speed for increased safety. Note We strongly recommend that you do not specify a higher speed than the hull unit is designed for. If the speed limit is exceeded a message is issued by the SY50 system. The SY50 system can be provided with one of the following hull units: Hull Unit Lowering depth (mm) Maximum speed (knots) SY50 400/600 10 SY50C 400 12 The same transducer is used on all hull unit types. Screen Recording We recommend that you do not make any changes to these settings. Recording We recommend that you do not make any changes to these settings. 5 At the bottom of the page, select Apply to save your settings. 6 Continue your work in the Installation dialog box, or select OK to close it. Related topics Configuring the SY50 system for normal operation, page 237 467020/B 239 Simrad SY50 Installation Manual Configuring the SY50 system for data recording Record allows you to record echo data. The data are saved on the hard disk, or on an external data storage device, according to the preferences you have defined. If necessary the files can be copied or moved to another storage device or a network drive. Prerequisites If you wish to save your recorded data on an external hard disk, make sure that it is connected to the computer. Context The File Setup settings control how and where the recorded files are saved on the hard disk, or on an external storage device. By adding a prefix to the file names you can identify the files you have recorded during a specific survey. You can also define a maximum size of the files. You can start and stop data recording in several ways. a Select the red circle on the right side of the Record RAW button. b Open the Record RAW button and select On. c Select the black rectangle to stop recording. The Record indicator on the top bar will switch to red colour when recording is active. The Record indicator can not be used to start or stop recording. Procedure 1 Open the Operation menu. 2 Locate the Record button. 3 Select the middle of the button to open it for access to the available options. 4 Select File Setup to open the dialog box. 5 On the Directory page, select Browse to choose a folder for the data files. The data files will normally become very large. If you wish to record large amounts of data, make sure that you have enough space on your hard disk. The SY50 system is not provided with unlimited disk capacity. We recommend that you either save the data files to an external storage device, or use a network disk. 6 On the Raw Data page, type a prefix into the File name prefix text field. If you do not have a computer keyboard connected to your SY50 system, select the Keyboard button to open an on-screen keyboard. 240 467020/B Setting to work 7 On the Raw Data page, define a maximum size for the data files. Tip Set the value to 0 (zero) if you do not wish to limit the file size. The Split File function will start a new file with the next ping regardless of the maximum file size you have defined. 8 On the Raw Data page, observe the Current file size field. The current size of the file you are recording is shown in this field. Data is only shown while recording is taking place. If the current file size gets too big during recording, select Split File on the Record button. This will close the current file, and then automatically continue recording to a new file. 9 Select OK to save the selected settings and close the dialog box. Related topics Configuring the SY50 system for normal operation, page 237 Configuring the environmental parameters Environmental parameters such as salinity, and sound speed play an important part to present accurate echo data. Use the Environment parameters to define these values. Depending on the current sea and weather conditions, you may need to change these values frequently. Context In order to obtain accurate echoes, it is very important that the sound speed through the water is set correctly. Several parameters are required to calculate the correct sound speed value. If these parameters are not known to you, use the default value 1494 m/s. This is a typical mean value for sound speed. Procedure 1 Open the Setup menu. 2 Select Environment. Observe that the Environment dialog box opens. 3 Specify if you work in fresh or salt water. 4 Specify the sound speed. 5 Select OK to save the selected settings and close the dialog box. Related topics Configuring the SY50 system for normal operation, page 237 467020/B 241 Simrad SY50 Installation Manual Selecting the language displayed in the menus and dialog boxes You may prefer to use the SY50 system with the user interface in your own language. The Language function allows you to select the language to be used in the display presentations, menus and dialog boxes. Context With a few exceptions, the chosen language will also be used for all other texts in the user interface. The context sensitive online help may not be available for the language you choose. If your language is not supported, the English help is provided. Procedure 1 Open the Setup menu. 2 Select the middle of the Language button to open the list of available options. 3 Select the language you wish to use. Result All the texts in the user interface are changed to the selected language. The context sensitive on-line help may also be available in your language. To change the language in the on-line help, you may need to restart the SY50 system. Related topics Configuring the SY50 system for normal operation, page 237 Saving the current user settings When you have spent some time working with the SY50 system, you are probably using specific settings that you know are efficient for your purpose. It is a good idea to save these settings. Context The User Settings dialog box is used to store your favourite settings. These settings can be related to different operations, environmental conditions or basic personal preferences. You can use different settings to create as many user profiles as you like, and give them any name. All the settings you have chosen using functions and dialog boxes in the user interface are saved. 242 467020/B Setting to work Procedure 1 Observe the Main menu. Its default location is on the right side of the display presentation. 2 Select User Settings. 3 Select Save Current Setting. A small dialog opens to accept the name of the new setting. 4 Type a name. Tip If you do not have a computer keyboard connected to your SY50 system, select the Keyboard button to open an on-screen keyboard. 5 Select OK to save the chosen name. 6 Observe that the name you have chosen appears on the Saved Settings list. 7 Select OK to close the dialog box. Related topics Configuring the SY50 system for normal operation, page 237 467020/B 243 Simrad SY50 Installation Manual Defining the user-selected features on the Operating Panel Topics Selecting which Operating Panel to use, page 244 Assigning user settings or presentation modes to the Operating Panel, page 245 Assigning functions to the rotary switches on the Operating Panel, page 247 Assigning functions to F1, F2 and F3 on the Operating Panel (Mk2), page 248 Selecting which Operating Panel to use The Operating Panel offers all necessary control functions for normal operation. Context The controls provided by the Operating Panel are arranged in logical functional groups. This offers you clear and easy operation with fast access to key functionality. All the functionality provided by the SY50 system can be accessed using the trackball on the Operating Panel and the menu system shown in the display presentation. The SY50 system supports two different operating panels. These are referred to as "Mk2" and "Mk3". • The Mk2 Operating Panel is connected to the Processor Unit using an Ethernet cable. • The Mk3 Operating Panel is connected to the Processor Unit with a USB cable. The Mk3 Operating Panel is the standard panel provided for the SY50 system. To select which operating panel to use, open the Operating Panel page in the Installation dialog box. The Installation dialog box is located on the Setup menu. Tip When you work in the Installation dialog box, you must always select Apply to save the changes made on a page. You must do this before you continue working on a different page. Procedure 1 244 Open the Setup menu. 467020/B Setting to work 2 On the Setup menu, select Installation. Observe that the Installation dialog box opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select Operating Panel. 4 Select which operating panel to use. 5 At the bottom of the page, select Apply to save your settings. 6 Continue your work in the Installation dialog box, or select OK to close it. Related topics Defining the user-selected features on the Operating Panel, page 244 Assigning user settings or presentation modes to the Operating Panel The User Settings dialog box is used to store your favourite settings. These settings can be related to different operations, environmental conditions or basic personal preferences. You can use different settings to create as many user profiles as you like, and give them any name. The Operating Panel allows you to assign certain functions to dedicated buttons and switches. This includes user settings and presentation modes. Prerequisites Before you can assign custom user settings to the operating panel, a selection of settings must be available from the User Settings dialog box. The User Settings dialog box is located on the Main menu. Context The Operating Panel page is used to select which physical hardware panel you use, and to assign functionality to the programmable buttons. This page is located in the Installation dialog box. The Installation dialog box is located on the Setup menu. 467020/B 245 Simrad SY50 Installation Manual • On the Mk2 Operating Panel, the four buttons dedicated for user settings or presentation modes are located the top of the panel. • On the Mk3 Operating Panel, the requested user setting or presentation mode is chosen with a single button. Press the button repeatedly to cycle through the settings or modes. Tip Any user setting selected on the Operating Panel is identified in the upper left corner of the Horizontal view. The identifying number refers to the User Setting number on the Operating Panel page. Click on the text to make it larger. Click one more time to restore the original font size. Procedure 1 Open the Setup menu. 2 On the Setup menu, select Installation. Observe that the Installation menu opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select Operating Panel. 4 Select the relevant operating panel. 5 Select Mode Selection to specify what you want to use the buttons for. 6 Assign one predefined user setting or presentation mode to each button on the Operating Panel. 7 At the bottom of the page, select Apply to save your settings. 8 Continue your work in the Installation dialog box, or select OK to close it. Related topics Defining the user-selected features on the Operating Panel, page 244 246 467020/B Setting to work Assigning functions to the rotary switches on the Operating Panel The Mk2 Operating Panel is fitted with three rotary switches. The Mk3 Operating Panel is fitted with two rotary switches. The switches are identified with numbers. Each switch can be assigned a function related to range, gain, bearing or tilt. The Mk1 Operating Panel does not support this functionality. Context The Operating Panel page is used to select which physical hardware panel you use, and to assign functionality to the programmable buttons. This page is located in the Installation dialog box. The Installation dialog box is located on the Setup menu. The following functions can be assigned: Horizontal Range This is the range setting in the Horizontal view. Vertical Range This is the range setting in the Vertical view. Inspection Range This is the range setting in the Inspection view. Horizontal Range 2 This is the range setting in the second Horizontal view when a "dual" presentation mode is used. Vertical Range 2 This is the range setting in the second Vertical view when a "dual" presentation mode is used. Plane Range This is the range setting in the Plane view. Active Ping Range This is the range setting in the currently active view. Active Ping Gain This is the gain setting in the currently active view Active Ping Bearing This is the bearing setting in the currently active view. Active Ping Tilt This is the tilt setting in the currently active view Procedure 1 Open the Setup menu. 467020/B 247 Simrad SY50 Installation Manual 2 On the Setup menu, select Installation. Observe that the Installation menu opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select Operating Panel. 4 Select Operating Panel Mk2. 5 Under Rotary Switch Options, assign one function to each rotary switch on the Operating Panel. 6 For the Mk3 Operating Panel, assign one function to each rotary switch when you press it. 7 At the bottom of the page, select Apply to save your settings. 8 Continue your work in the Installation dialog box, or select OK to close it. Related topics Defining the user-selected features on the Operating Panel, page 244 Assigning functions to F1, F2 and F3 on the Operating Panel (Mk2) The Mk2 Operating Panel is fitted with three function buttons. The buttons are identified as F1, F2 and F3. Each button can be assigned a dedicated function. Context The Operating Panel page is used to select which physical hardware panel you use, and to assign functionality to the programmable buttons. This page is located in the Installation dialog box. The Installation dialog box is located on the Setup menu. 248 467020/B Setting to work The three function buttons are grouped with the Screen Capture button. The following functions can be assigned: Auto Tilt This is an "on/off" function. When Auto Tilt mode is activated the beam will automatically change its tilt angle for each transmission ("ping"). The centre of the tilt sector is defined by the chosen tilt angle just before the Auto Tilt mode is started. The chosen tilt sector is shown on the tilt indicator in the Horizontal view using a shaded background. The sector and step settings are made using the Tilt function on the Main menu. Off Centre This is the same function as Set New Ship Centre on the shortcut menu. Place the cursor anywhere in the view and press the button. The function moves the vessel symbol to the selected position. Zoom Place the cursor anywhere in the view, right-click and select Zoom. Only one zoom level is provided. Select Zoom one more time to restore the original view. Menu Off This is an "on/off" function. Unless you need to make frequent changes to the operating parameters, you may want to hide the menu from the display presentation. This gives you more space for echo information. Own Ship This is the same function as Place Own Ship Marker on the shortcut menu. Select this function to add a square symbol to the vessel’s current position in the echo presentation. The own ship marker is now regarded as an object. All information about the object is shown in the Objects menu listed as "OSM". Use Delete Own Ship Marker on the shortcut menu to delete the marker from the current view. Auto Bearing This is an "on/off" function. Set this function to On to start the automatic search function. In the Auto Bearing mode the SY50 system will automatically search within defined sector limits. The sector is identified in the view using two angular symbols. The sector and step settings are made using the Bearing function on the Main menu. Procedure 1 Open the Setup menu. 467020/B 249 Simrad SY50 Installation Manual 2 On the Setup menu, select Installation. Observe that the Installation menu opens. This dialog box contains a number of pages selected from the menu on the left side. 3 On the left side of the Installation dialog box, select Operating Panel. 4 Select which operating panel to use. 5 Under Button Options, assign one function to each Fx button on the Operating Panel. 6 At the bottom of the page, select Apply to save your settings. 7 Continue your work in the Installation dialog box, or select OK to close it. Related topics Defining the user-selected features on the Operating Panel, page 244 250 467020/B Setting to work Testing the operating functionality of the SY50 system Topics Checking the hull unit lowering and hoisting functionality, page 251 Measuring the noise in passive mode, page 254 Verifying system operation by means of the Diagnostics functionality, page 256 Verifying system operation by means of the Element BITE functionality, page 260 Making a noise/speed curve to determine vessel noise, page 264 Checking the hull unit lowering and hoisting functionality The hull unit is used to lower the transducer down below the ship’s hull when the SY50 system shall be used. This is a key functionality of the SY50 system. It is very important that the hoist/lower function is tested before the SY50 system is put to operational use. To test the lower and hoist functionality two tasks must be done at the same time. Two persons are needed. • One person must stay on the bridge in order to operate the SY50 system. • One person must stay in the sonar room to make sure that the SY50 system starts, and that the hull unit works properly. Proper oral communication must exist between the bridge and the sonar room. Note This test can only be done if the water depth allows the transducer to be lowered completely. If this is not the case, the vessel must be moved to another location, or the test must be cancelled. Kongsberg Maritime cannot take responsibility for tests that are cancelled for this reason. Certain steps in the procedures are location specific. The steps marked [Sonar room] are done in the sonar room. The steps marked [Bridge] are done on the bridge. WARNING The transducer may be damaged if it transmits in open air. Topics Bridge steps, page 252 467020/B 251 Simrad SY50 Installation Manual Sonar room steps, page 253 Bridge steps These tasks are done on the bridge. Prerequisites The SY50 system is turned on and operates normally. Neither tools nor instruments are required. Context Certain steps in the procedures are location specific. The steps marked [Sonar room] are done in the sonar room. Procedure 1 Make sure that you have sufficient water depth below the keel before you lower the transducer. 2 Lower the transducer to its bottom position. a On the Operating Panel, press Down. While the transducer is moving the indicator lamp flashes, and an audible signal is sounded. When the requested position has been reached, the indicator lamp is lit, and the audible signal stops. b 3 [Sonar room]: When the transducer shaft stops, verify that the correct bottom position has been reached. Hoist the transducer to its upper position. a On the Operating Panel, press Up. While the transducer is moving the indicator lamp flashes, and an audible signal is sounded. When the requested position has been reached, the indicator lamp is lit, and the audible signal stops. b 4 Lower the transducer to its bottom position. a 252 [Sonar room]: When the transducer shaft stops, verify that the correct upper position has been reached. On the Operating Panel, press Down. 467020/B Setting to work b 5 [Sonar room]: When the transducer shaft stops, verify that the correct bottom position has been reached. Hoist the transducer to its upper position. a On the Operating Panel, press Up. b [Sonar room]: When the transducer shaft stops, verify that the correct upper position has been reached. 6 Repeat the test using the Hull Unit Control dialog box on the top bar. 7 Notify the sonar room that the test is finished. Sonar room steps These tasks are done in the sonar room. Prerequisites The SY50 system is turned on and operates normally. Neither tools nor instruments are required. Context Certain steps in this procedure are location specific.The steps marked [Bridge] are done on the bridge. Procedure 1 [Bridge]: Make sure that you have sufficient water depth below the keel before you lower the transducer. 2 [Bridge]: Lower the transducer to its bottom position. 3 4 a Make sure that the transducer can be lowered without complications or obstacles. b When the transducer shaft stops, verify that the correct bottom position has been reached. [Bridge]: Hoist the transducer to its upper position. a Make sure that the transducer can be hoisted without complications or obstacles. b When the transducer shaft stops, verify that the correct upper position has been reached. [Bridge]: Lower the transducer to its bottom position. a Make sure that the transducer can be lowered without complications or obstacles. b When the transducer shaft stops, verify that the correct bottom position has been reached. 467020/B 253 Simrad SY50 Installation Manual 5 [Bridge]: Hoist the transducer to its upper position. a Make sure that the transducer can be hoisted without complications or obstacles. b When the transducer shaft stops, verify that the correct upper position has been reached. 6 [Bridge]: Repeat the test using the Hull Unit Control dialog box on the top bar. 7 [Bridge]: Notify the sonar room that the test is finished. Measuring the noise in passive mode Low noise is a key factor for high quality and reliable measurements. The performance of the SY50 system will always be limited by different noise sources. A high noise level will mask the echoes and make them difficult to read and interpret. The noise is measured while the SY50 system operates in Passive mode with the transmit pulses disabled. Prerequisites The SY50 system is turned on and operates normally. • The SY50 system is in Normal mode, but TX Power is set to Off to prevent transmissions. • The transducer is retracted to its upper position. • Neither tools nor instruments are required. In order to do this test, the ship must be "silent". • The water must be as deep as possible. Recommended minimum depth is 100 metres. • There must be no other vessels in the vicinity. • The vessel must lie still in the water. • As much machinery as possible must be turned off. It is particularly important to turn off electrical motors, as well as cooling systems and hydraulic pumps that may cause electric noise. • To prevent interference, all other hydroacoustic instruments must be turned off. Note With the vessel in port, the environmental conditions are not satisfactory. In the shallow waters of the port, noise from other vessels, dockyard workers or machinery will cause unreliable test results. If you do this tests in a busy harbour, or with noise sources present, the sensitive receivers will detect all the noise in the nearby waters. Context This task allows you to check the noise conditions. To measure the noise level, observe the value presented on the Noise page in the Diagnostics dialog box. 254 467020/B Setting to work Procedure 1 Make sure that you have sufficient water depth below the keel before you lower the transducer. 2 Lower the transducer to its bottom position. 3 Select the default settings. a On the Main menu, select User Settings. b Observe the Factory Settings list. c Select the setting you want to use. d Select Activate Selected Setting. e Select OK to apply your changes and close the User Settings dialog box. 4 At the bottom of the display presentation, select a suitable presentation mode, and activate the Horizontal view. 5 Make the following preparations. a On the Main menu: Set Range to 1500 m. b On the Operation menu: Set Tx Power to Off. c On the Active menu: d 1 Set Pulse Type to CW Medium. 2 Set Frequency to the start frequency:70 kHz 3 Set Vertical TX Sector to Narrow. 4 Set Noise Filter to Off. 5 Set the Bottom Filter Threshold to Off. On the Setup menu: Select Diagnostics to open the dialog box. 6 Select Noise to open the page. 7 Select Start Noise Measurements. 8 a Observe the noise curve. b Read the maximum and average noise values. c Repeat for selected frequencies. d Record the frequencies and the measured values in the result table. Finish the test. a Close the Diagnostics dialog box. b Hoist the transducer back up to its upper position. 467020/B 255 Simrad SY50 Installation Manual Result For each transmit frequency (in kHz), write down the measured noise levels (in dB). Frequency Maximum Average 70 kHz 57 kHz 90 kHz Verifying system operation by means of the Diagnostics functionality The purpose of the Diagnostics dialog box is to allow on-line testing and verification of the hardware components in the SY50 system. The Transceiver page offers key information about each transceiver board in the Transceiver Unit. Use the Transducer page to do a reception test to check the individual transducer elements. Any errors are then easily detected. Prerequisites The SY50 system hardware units are installed as specified in this manual. • The SY50 system is turned on and operates normally. • The SY50 system is in Normal mode, but TX Power is set to Off to prevent transmissions. • The transducer is retracted to its upper position. • The vessel is berthed or at sea. Caution You must never set the SY50 system to "ping" unless the transducer is submerged in water. The transducer may be damaged if it transmits in open air. Neither tools nor instruments are required. For the best possible conditions, the ship must be "silent". • The water must be as deep as possible. Recommended minimum depth is 100 metres. • There must be no other vessels in the vicinity. • The vessel must lie still in the water. 256 467020/B Setting to work • As much machinery as possible must be turned off. It is particularly important to turn off electrical motors, as well as cooling systems and hydraulic pumps that may cause electric noise. • To prevent interference, all other hydroacoustic instruments must be turned off. Context By means of the Diagnostics functionality, you can easily determine if the hardware components in the SY50 system are operational. And most important, you can make sure that all the transceivers channels and transducer elements are functional. Each button provides a small colour coded indicator. • No indicator: Status is OK. No actions are necessary. • Yellow: This is a warning. A closer investigation is recommended. • Red: This is an alarm. A closer investigation is required. • Blue: A device monitored by the diagnostic system is disabled. • Grey: No information is available. Note The Diagnostics dialog box and functionality is only provided for performance monitoring. The functionality offered by the dialog box is not required for normal use of the SY50 system. The dialog box does not permit you to change any operational settings. Procedure 1 Make sure that you have sufficient water depth below the keel before you lower the transducer. 2 Lower the transducer to its bottom position. 3 Select the default settings. 4 a On the Main menu, select User Settings. b Observe the Factory Settings list. c Select the setting you want to use. d Select Activate Selected Setting. e Select OK to apply your changes and close the User Settings dialog box. Make the following preparations. a On the Main menu: Set Range to 1500 m. b On the Operation menu: Set Tx Power to Off. c On the Active menu: 467020/B 1 Set Pulse Type to CW Medium. 2 Set Frequency to the start frequency:70 kHz 257 Simrad SY50 Installation Manual d 5 3 Set Vertical TX Sector to Narrow. 4 Set Noise Filter to Off. 5 Set the Bottom Filter Threshold to Off. On the Setup menu: Select Diagnostics to open the dialog box. Select Transceiver to open the page. The Transceiver page provides a graphic presentation of the transceiver boards. The visual presentation reflects the physical location of the boards in the Transceiver Unit. Only static information is provided. The Board Information parameters offer key information about the supply power to the selected transceiver board, as well as the environmental conditions. 6 Make sure that all the transceiver boards are fully functional. 7 Select Transducer to open the page. The Transducer page presents all the elements that are used in the transducer. The presentation attempts to organize the elements in the same manner as in the physical transducer. The transceiver boards are shown as "buttons". Select a transceiver board to highlight the elements that are physically connected to the board. 8 Select Reception Test to start an automatic test of the individual transducer elements. The reception test validates each single element in the transducer, and returns the status using a simple colour code. • Green: The transducer element is fully operational. • Red: The transducer element offers reduced performance. • Black: The transducer element is not working ("dead"). For more information, observe the tooltip provided for each element rectangle. 9 Make sure that the number of unserviceable ("dead") elements does not degrade the performance of the SY50 system. A small number of unserviceable transducer elements are accepted, even for operational use. This is regarded as "graceful degradation”. The SY50 system offers a large number of transceiver channels. 000 identical transceiver boards are used. If a single channel fails during normal operation, you are not likely to detect it. Even if several channels fail, you may not see it. The detection of a faulty channel depends on the physical location of the relevant transducer element. If faulty channels are grouped together on the transducer face, this may cause a visible defect in the display presentation. If they are scattered, the visible defect may be a lot harder to see. In all cases, the echoes from the neighbouring channels cause an interpolation that will restore a lot of the degraded presentation. Which actions to take if single channels fail depend on the operational impact, the overall performance of the SY50 system, and a cost/benefit assessment. The most important factor in the cost/benefit assessment is whether you need to replace the 258 467020/B Setting to work transducer, or just a single transceiver board. If more than 3% of your transducer elements have failed, we recommend that you contact your dealer for advice. Note For further investigations of this issue, use the functionality offered by the Element BITE (Element Built In Test Equipment) dialog box. 10 If the result from the reception test shows a number of transducer elements that are either defective or offer reduced performance, repeat the test. With the vessel in port, the environmental conditions are not satisfactory. In the shallow waters of the port, noise from other vessels, dockyard workers or machinery will cause unreliable test results. If you do this tests in a busy harbour, or with noise sources present, the sensitive receivers will detect all the noise in the nearby waters. Excessive noise or interference may be misinterpreted as physical defects. You may need to repeat the test several times, and - if necessary - implement a "silent ship" to improve the conditions. 11 Finish the test. a Close the Diagnostics dialog box. b Set Tx Power to Off. c Hoist the transducer back up to its upper position. Result Requirements Results The maximum number of bad elements is: 00 Date and signature: Further requirements If the noise level is higher than specified, you must check the reason(s) for this. • Verify that other electric equipment and/or machinery on board, such as cooling systems, hydraulic pumps, electric motors etc, do not influence on the noise reading. Switch off as much machinery as possible, especially electrical motors. • Check for interference from other hydroacoustic systems. • Check for environmental noise, such as other vessels in the vicinity or animal life. 467020/B 259 Simrad SY50 Installation Manual Verifying system operation by means of the Element BITE functionality The purpose of the Element BITE (Element Built-In Test Equipment) dialog box is to allow on-line test and verification of the individual elements in the transducer. It allows you to see if the transducer elements are operational during transmission and reception. The B-Scan page allows you to monitor the data received from each of the elements in the transducer. The start sample and the number of samples to be displayed are selectable. Prerequisites The SY50 system hardware units are installed as specified in this manual. • The SY50 system is turned on and operates normally. • The SY50 system is in Normal mode, but TX Power is set to Off to prevent transmissions. • The transducer is retracted to its upper position. • The vessel is berthed or at sea. Caution You must never set the SY50 system to "ping" unless the transducer is submerged in water. The transducer may be damaged if it transmits in open air. Neither tools nor instruments are required. Context By means of the Element BITE (Element Built-In Test Equipment) functionality, you can easily determine if the SY50 hardware is operational. The following pages are provided: Matrix The Matrix page allows you to monitor the average signal values or signal phases from each of the channels and transducer elements in the SY50 system. The presentation is provided on a matrix corresponding to the element locations in the transducer. B-Scan The B-Scan page allows you to monitor the data received from each of the elements in the transducer. The start sample and the number of samples to be displayed are selectable. In the B-Scan presentation, each element in the transducer is shown as a long coloured vertical rectangle. If you place the cursor on top of one of these rectangles, a small yellow tool-tip will identify key information about the channel. • The identification of the transducer element • The identification of the transceiver board • The current sample you are looking at 260 467020/B Setting to work • The measured echo value (in dB) Procedure 1 Make sure that you have sufficient water depth below the keel before you lower the transducer. 2 Lower the transducer to its bottom position. 3 Select the default settings. 4 a On the Main menu, select User Settings. b Observe the Factory Settings list. c Select the setting you want to use. d Select Activate Selected Setting. e Select OK to apply your changes and close the User Settings dialog box. Make the following preparations. a On the Main menu: Set Range to 1500 m. b On the Operation menu: Set Tx Power to Off. c On the Active menu: d 1 Set Pulse Type to CW Medium. 2 Set Frequency to the start frequency:70 kHz 3 Set Vertical TX Sector to Narrow. 4 Set Noise Filter to Off. 5 Set the Bottom Filter Threshold to Off. On the Setup menu: Select Diagnostics to open the dialog box. 5 Select Processor to open the page. 6 Open the Element BITE (Element Built-In Test Equipment) dialog box. 7 a Select Element BITE to open the dialog box. b Select the B-Scan tab to open the page. c Select Element amplitude. Test the receiver performance. a Set Start sample to 5000. b Set Sample range to 10000. 467020/B 261 Simrad SY50 Installation Manual c Look at the pattern in the B-Scan presentation, and compare them with the example provided. This screen capture shows the B-Scan pattern while testing the receiver in the near range. This is a generic illustration. Any similarities with specific products are accidental. To detect unserviceable transducer elements and/or transceiver boards, you must compare the rectangles. When operating the SY50 system in port, the colours will be less homogeneous due to the environmental noise and the shallow depth. During normal operation at sea the colours will be homogeneous. • If a single element is "dead" (no transmit, no receive), the rectangle is easily spotted because its colour is black. • If a single element is receiving, but not transmitting, the rectangle is normally presented in lighter shades of blue. • If a transceiver board is "dead" (no transmit, no receive), all the transducer elements connected to the board are easily spotted because they are all black. 8 262 Test the transmitter performance. a Set Tx Power to Maximum. b Set Start sample to 50 c Set Sample range to 2000 467020/B Setting to work d Look at the pattern in the B-Scan presentation, and compare them with the example provided. This screen capture shows the B-Scan pattern while testing the transmitter. You can clearly see the transmit pulse. 9 Make sure that there are no weak elements in the transmission sample range. If any weak elements are detected, record these in the result table. 10 Make sure there are no black lines in the transmission and reception sample range. A black line indicates an unserviceable transducer element. If any such elements are detected, record these in the result table. 11 Finish the test. a Close the Element BITE (Element Built-In Test Equipment) dialog box. b Close the Diagnostics dialog box. c Set Tx Power to Off. d Set Operation to Inactive. e Hoist the transducer back up to its upper position. Result Requirements Results The information presented by the B-Scan page verifies that the SY50 system is fully operational. All elements are operational in both transmit and receive. The maximum number of bad elements is: 00 Weak elements: 467020/B 263 Simrad SY50 Installation Manual Requirements Results Unserviceable elements: Date and signature: Making a noise/speed curve to determine vessel noise The performance of the SY50 system will always be limited by different noise sources. During this test, noise measurements are done for different vessel speeds. The weather and sea conditions for the noise measurements will be those at the time of the test. Prerequisites The SY50 system is turned on and operates normally. The vessel is at sea. Recommended minimum depth is 100 metres. If the SY50 system is operated from any other compartment than the bridge, an open two-way oral communication channel with the bridge is required. You need the following equipment: • Personal computer • Spreadsheet program If you wish to do the test with a "silent ship" the following prerequisites must be met: • The water must be as deep as possible. Recommended minimum depth is 100 metres. • There must be no other vessels in the vicinity. • As much machinery as possible must be turned off. It is particularly important to turn off electrical motors, as well as cooling systems and hydraulic pumps that may cause electric noise. • To prevent interference, all other hydroacoustic instruments must be turned off. If you do this tests in a busy harbour, or with noise sources present, the sensitive receivers will detect all the noise in the nearby waters. Context To measure the noise, observe the noise values provided on the Noise page in the Diagnostics dialog box. Since the noise will vary with each ping, you must make five measurements for each vessel speed, and then calculate the average noise. Tip If you record all the raw data during the noise test, you can repeat the test later using the replay file. You may wish to make the noise/speed curve under realistic conditions. This means that all relevant vessels systems are in normal use. If you experience very high noise levels, you may wish to repeat the test with "silent ship" settings. To isolate noise sources, turn individual vessel systems off, and check for any changes in the noise level. 264 467020/B Setting to work Note When the transducer is fully lowered, the speed of the vessel must not exceed the maximum speed permitted for the hull unit. This maximum speed depends on the physical size of the transducer, the mechanical construction of the hull unit, and how far down the transducer has been lowered. The System Protection page allows you to define a limit that triggers an alarm if the maximum speed is exceeded. The System Protection page is located in the Installation dialog box. Illustration: Read the noise value from the noise circle. Use the mean value of the readouts at 0 degrees (straight up). Procedure 1 Make sure that you have sufficient water depth below the keel before you lower the transducer. 2 Lower the transducer to its bottom position. 3 If necessary, establish a separate communication line with the bridge to verify the vessel speed during the test. 4 Make the following preparations. a At the bottom of the display presentation, select Bow Up presentation mode, and activate the Horizontal view. b Open the Operation menu. c d 467020/B 1 Set Operation to Normal. 2 Set Tx Power to Off. Open the Active menu. 1 Set TVG (Time Variable Gain) to 0 log R. 2 Set Ping-Ping Filter to Off. 3 Set Pulse Type to CW Short. 4 Set Frequency to the start frequency: 5 Set Horizontal TX Sector to Omni. 6 Set Vertical TX Sector to Normal. 7 Set AGC (Automatic Gain Control) to Off. 8 Set RCG (Reverberation Controlled Gain) to 0 (zero). 9 Set Noise Filter to Off. Open the Setup menu. 265 Simrad SY50 Installation Manual 5 e Select Diagnostics to open the dialog box. f Select Noise to open the page. g Select Start Noise Measurements. Repeat for each vessel speed and operating frequency. a Ask the bridge to set the speed. b If possible, verify the vessel speed on the top bar. c Read the noise value from the noise circle. d Record the values in the result table. e Repeat for every 2 kHz up to and including the highest test frequency: 90 kHz f 1 Increase the operating frequency with 2 KHz. 2 Read the noise value from the noise circle. 3 Record the values in the result table. Ask the bridge to set the next speed. 6 When all the measurements have been made, type the data (speed and noise) into a spreadsheet to create the curve. 7 Finish the test. a Close the Diagnostics dialog box. b Hoist the transducer back up to its upper position. Result Speed/Frequency/Noise Speed Frequency Noise level 0 2 4 6 8 10 266 467020/B Setting to work Speed/Frequency/Noise Frequency Speed Noise level 12 14 16 18 20 Sea state: Water depth: Use this table to record the values. Print it out and make multiple copies. Alternatively, you can type the values straight into a spreadsheet. Requirements Results A noise/speed curve is created. Date and signature: 467020/B 267 Simrad SY50 Installation Manual Creating a backup with the SY50 configuration and software installation Topics About SY50 software backup and restore, page 268 Creating a computer image on a USB flash drive using the Acronis True Image program, page 268 Restoring a computer image from a USB flash drive using the Acronis True Image program, page 270 Creating a bootable USB flash drive using the Acronis True Image program, page 271 About SY50 software backup and restore Once the configuration and testing have been finalized, it is good practice to back up the configuration data and software installation. Software backup is provided using dedicated software applications and commercial storage devices. Note We strongly advice you to create your own backup once the installation has been completed. Your backup will then include the operating system, the SY50 software, as well as all the interface parameters that you have defined. A backup "image" is a very useful feature. It allows you to create and save a complete copy of all the files on the computer hard disk. Once a backup image exist, you can restore the content of the computer hard disk in case of a failure. Creating a computer image on a USB flash drive using the Acronis True Image program A backup "image" is a very useful feature. It allows you to create and save a complete copy of all the files on the computer hard disk. The software used is Acronis True Image. The software is installed on the Processor Unit. It is also copied onto the USB flash drive that is provided with the SY50 system. Prerequisites To create the backup image, you need the bootable USB flash drive provided with the SY50 system. You can also use any commercial USB flash drive, but it must be bootable, and it must have the necessary storage capacity. 268 467020/B Setting to work Context The software in use is created by Acronis. For more information about this company and their products, see their website: • Manufacturer: Acronis International GmbH • Manufacturer’s website: http://www.acronis.com Procedure 1 Boot the computer from the USB flash drive. a Connect a mouse and a computer keyboard to the computer. b Insert the bootable USB flash drive. c Turn on the computer manually using the on/off button. d Observe that the computer boots from the USB flash drive. If the computer does not start from the USB flash drive, reboot, and start the BIOS application to select boot device. 2 Start the Acronis True Image program. 3 On the first page, select Back Up→My Disks. 4 On page Partitions to back up, observe that the only partition available is selected. 5 Select Next. 6 On page Target backup archive: a Select Create new backup archive. b Select Browse to define the location of the backup file. c Wait while the computer processes your request. This may take some time (up to several minutes) if you are using a new USB flash drive. 7 In the Browse for location dialog box, select the USB flash drive, the folder you wish to use, and the file name. 8 Click the small arrow button on the right side of the Generate name button to add date to the file name. 9 Select OK. 10 Select Next. 11 Select Proceed. 12 Wait for the backup process to finish. 13 Stop the Acronis True Image program. 14 Remove the USB flash drive. 15 Restart the computer. 467020/B 269 Simrad SY50 Installation Manual Restoring a computer image from a USB flash drive using the Acronis True Image program Once a backup image exist, you can restore the content of the computer hard disk in case of a failure. The software used is Acronis True Image. The software is installed on the computer. It is also copied onto the USB flash drive that is provided with the SY50 system. Prerequisites To restore, you will need the USB flash drive containing a backup image. We recommend that you use the image you made after the system installation was completed. Context You can restore the image from generic backup image, or from an image created for your installation. Note If you restore your Processor Unit from a generic image, you must change the Windows license and then activate it before you can use the SY50. You must also reinstall the SY50 system software. We recommend that you use the image you made after the system installation was completed. The software in use is created by Acronis. For more information about this company and their products, see their website: • Manufacturer: Acronis International GmbH • Manufacturer’s website: http://www.acronis.com Procedure 1 Boot the computer from the USB flash drive. a Connect a mouse and a computer keyboard to the computer. b Insert the bootable USB flash drive. Use the USB sockets on the rear side of the Processor Unit. Avoid the blue USB sockets, as these do not support the boot functionality c Turn on the computer manually using the on/off button. d Observe that the computer boots from the USB flash drive. If the computer does not start from the USB flash drive, reboot, and start the BIOS application to select boot device. 2 Start the Acronis True Image program. 3 On the first page, select Recover. 4 On the second page, select Browse for backup. 270 467020/B Setting to work 5 Locate and select the backup file. The file format is *.tib. 6 Select OK. 7 On the list of image files, right-click on the image, and select Recover in the short-cut menu. a On the Recovery Method page, select Recover whole disks and partitions. b Select Next. c On page Select the items to recover, select Disk 1. d Select Next. e On page Disk properties, select Disk 1. f Select Next. If the hard disk on the computer contains data, a confirmation dialog box appears to remind you that all data on the hard disk will be lost. 8 g Select OK. h Select Proceed. i Select Shut down the computer when recovery is completed. Wait for the recovery process to finish. Once completed, the computer is turned off. 9 Remove the USB flash drive. 10 Restart the computer. Creating a bootable USB flash drive using the Acronis True Image program A bootable USB flash drive is required for backup purposes. The software used is Acronis True Image. The software is installed on the computer. It is also copied onto the USB flash drive that is provided with the SY50 system. Prerequisites In order to create a bootable USB flash drive you will need the actual device. We strongly recommend that you use a high capacity and high speed version. Avoid typical "give-away" USB flash drives and commercial low budget types. Context The software in use is created by Acronis. For more information about this company and their products, see their website: • Manufacturer: Acronis International GmbH • Manufacturer’s website: http://www.acronis.com 467020/B 271 Simrad SY50 Installation Manual Procedure 1 Insert the USB flash drive you wish to use. 2 Start the Acronis True Image program. 3 Select the Backup and recovery tab, and then select Create bootable media tool bar. a On page Welcome to Acronis Media Builder, do nothing. b Select Next. c On page Rescue media contents selection, select True Image. d Select Next. e On page Bootable media options, do nothing. f Select Next. g On page Bootable media type selection, select Removable Disk. h Select Next. i On page Acronis Media Builder is ready to start...., select Proceed. 4 Wait while the USB flash drive is made bootable. 5 Remove the USB flash drive from the computer using the "Safely remove hardware" feature in the operating system. 272 467020/B Setting to work Installation remarks Use this page to write down comments and remarks related to the SY50 installation. When the installation has been fully completed, and all functional tests have been made to full satisfaction, representatives from each party must sign. Vessel/Customer Place and date Comments Signatures Installation done by Company/Position Date and signature Installation accepted by Company/Position Date and signature 467020/B 273 Simrad SY50 Installation Manual Technical specifications Topics Introduction to technical specifications, page 275 Performance specifications, page 275 Power requirements, page 279 Weights and outline dimensions, page 282 Environmental requirements, page 285 Compass safe distance, page 288 Minimum display requirements, page 290 274 467020/B Technical specifications Introduction to technical specifications These technical specifications summarize the main functional and operational characteristics of the SY50 Fish-finding sonar. They also provide information related to power requirements, physical properties and environmental conditions. Note At Kongsberg Maritime, we are continuously working to improve the quality and performance of our products. The technical specifications may be changed without prior notice. Performance specifications These performance specifications summarize the main functional and operational characteristics of the SY50 system. Operating frequency • Start frequency: 54 kHz • End frequency: 60 kHz • Frequency steps: 1 kHz Operational range • Minimum: 25 metres • Maximum: 2500 metres • Maximum theoretical range: 2000 metres Even though you can choose a large range value, that does not mean that you can detect your targets on the same range. The range value only defines the range that is shown in the views. Actual target detection will always depend on the operational environment, such as water temperature, salinity, interference and layers in the water column. Tilt function • Horizontal views: –10 to +60 degrees • Vertical views: 0 to +90 degrees • Plane view: –10 to +90 degrees • Inspection view: –10 to +60 degrees Transmission • Number of transmitter channels: 256 • Horizontal TX Sector 467020/B 275 Simrad SY50 Installation Manual – Maximum: 360 degrees (Omnidirectional) – Other options: 30, 60, 90, 120, 180, 360 degrees • Vertical TX Sector: – Horizontal swath ∗ Maximum: Wide ∗ Other options: Narrow, Normal, Wide, Auto – Vertical swath ∗ Maximum: 90 degrees ∗ Other options: 30, 60, 90 degrees The options provided by this function depend on your current active view. • Pulse forms: – CW (Continuous Wave) transmissions – HFM (Hyperbolic Frequency Modulation) transmissions (This pulse type is also known as "chirp".) – LFM (Linear Frequency Modulation) transmissions (This pulse type is also known as "chirp".) Reception • Number of receiver channels: 256 • Gain functions: – TVG (Time Variable Gain) – AGC (Automatic Gain Control) – RCG (Reverberation Controlled Gain) • Digital filters: – Ping-Ping Filter – Noise Filter – FM Correlation filter – Bottom Filter Echo presentations • Display resolution: 1280 x 1024 pixels (Minimum). The visual quality of the presentation depends on the quality of your graphic adapter and display. We recommend that you use a large display with resolution 1920 x 1080. • Colours: A selection of echo colours is available to fit your presentation preferences. Each selection represents a dedicated colour scale. • Palettes: A choice of colour palettes is available to fit ambient light conditions. 276 467020/B Technical specifications Beamwidths • User selectableNarrow, Normal or Wide Stabilization • Roll stabilisation: ±20 degrees (Automatic) • Pitch stabilisation: ±20 degrees (Automatic) • External stabilisation sensor: The SY50 system has been designed to match the motion reference unit (MRU) sensors manufactured by our Seatex division. Interface to an optional peripheral motion reference unit (MRU) is supported Interfaces • Interfaces to peripheral devices: – Serial lines – Ethernet (LAN) line • Optional interfaces: – Scientific output (Ethernet line) – RAW data output for scientific research (Ethernet line) User interface • Main control: The Operating Panel offers all necessary control functions for normal operation. • Secondary control: A comprehensive menu system allows access to all SY50 system functionality. • Optional control: You can also use a standard computer mouse to control the SY50 system. • Menu languages: The text in the menu buttons in the user interface can be provided in several different languages. With a few exceptions, the chosen language is also used for all other texts. Hull Unit • Make: SY50 Hull Unit • Model: SY50 – Lowering depth: 400/600 mm – Maximum speed: 10 knots You can lower and hoist the transducer at any vessel speed below this. • Model: SY50C – Lowering depth: 10 mm – Maximum speed: 12 knots 467020/B 277 Simrad SY50 Installation Manual You can lower and hoist the transducer at any vessel speed below this. Type approval: DnV Certificate S-6344 Installation trunk The installation trunk is not included in the standard delivery. The installation trunk may be fabricated by the shipyard, or supplied by us as an option. Transducer The same transducer is used on all hull unit types. Shape: Cylindrical Number of individual elements: 256 278 467020/B Technical specifications Power requirements These power characteristics summarize the supply power requirements for the SY50 system. Topics Display power requirements, page 279 Nexcom NISE 3900E Processor Unit power requirements, page 279 Operating Panel power requirements (Mk2), page 280 Operating Panel power requirements (Mk3), page 280 Power Supply Unit power requirements, page 280 Hull Unit power requirements, page 281 Display power requirements Not applicable. The display is not a part of the SY50 scope of supply. It is not manufactured by Kongsberg Maritime. For more information, refer to the end-user documentation provided by the manufacturer. Related topics Power requirements, page 279 Technical specifications, page 274 Nexcom NISE 3900E Processor Unit power requirements • Manufacturer: Nexcom • Manufacturer’s website: https://www.nexcom.com • Model: Nexcom NISE 3900E • Voltage requirement: 9–30 VDC • Power consumption: 120 W @ 24 VDC (Approximately) The technical specifications are those valid for the computer that is provided by Kongsberg Maritime as a part of the SY50 system. For specifications related to a locally purchased computer, refer to the documentation provided with the unit. 467020/B 279 Simrad SY50 Installation Manual The technical specifications are those valid for the computer that is provided by Kongsberg Maritime as a part of the SY50 system. For additional details, refer to the technical specifications provided by the manufacturer. Note This information was copied from the manufacturer’s documentation. To ensure that your information is correct, always consult the manufacturer’s own documents. Related topics Power requirements, page 279 Technical specifications, page 274 Operating Panel power requirements (Mk2) • Make and model: SY50 Operating Panel (Mk2) • Voltage requirement: 115/230 VAC, 47 to 63 Hz, single phase, nominal • Maximum voltage deviation: 15% • Maximum transient: 20% of nominal voltage, recovery time 3 s • Power consumption: 10 W (Approximately) Related topics Power requirements, page 279 Technical specifications, page 274 Operating Panel power requirements (Mk3) • Make and model: SY50 Operating Panel Mk3 • Voltage requirement: Not applicable This unit is powered by means of the USB connection. Related topics Power requirements, page 279 Technical specifications, page 274 Power Supply Unit power requirements • Make and model: SY50 Power Supply Unit • Voltage requirement: – 230 VAC (47 to 63 Hz/Single phase/Nominal voltage) 280 467020/B Technical specifications or – 24 VDC • Maximum voltage deviation (VAC): 15% • Maximum transient (VAC): 20% of nominal voltage, recovery time 3 s • Power consumption: – Hoisting motor running: 600 W (Approximately) – Hoisting motor idle: 80 W (Approximately) Hull Unit power requirements • Make and model: Hull Unit SY50 • Model: SY50/SY50C – Voltage requirement: Not applicable All necessary operating power is provided by the Power Supply Unit. Related topics Power requirements, page 279 Technical specifications, page 274 467020/B 281 Simrad SY50 Installation Manual Weights and outline dimensions These weights and outline dimension characteristics summarize the physical properties of the SY50 system. Topics Display weight and outline dimensions, page 282 Nexcom NISE 3900E Processor Unit weight and outline dimensions, page 282 Operating Panel weight and outline dimensions (Mk2), page 283 Operating Panel weight and outline dimensions (Mk3), page 283 Power Supply Unit weight and outline dimensions, page 284 Hull Unit weight and outline dimensions, page 284 Display weight and outline dimensions Not applicable. The display is not a part of the SY50 scope of supply. It is not manufactured by Kongsberg Maritime. For more information, refer to the end-user documentation provided by the manufacturer. Related topics Weights and outline dimensions, page 282 Technical specifications, page 274 Nexcom NISE 3900E Processor Unit weight and outline dimensions • Manufacturer: Nexcom • Manufacturer’s website: https://www.nexcom.com • Model: Nexcom NISE 3900E • Outline dimensions (without mounting bracket): – Depth: 272 mm – Width: 215 mm – Height: 94 mm • Weight: 5 kg (Approximately) 282 467020/B Technical specifications The technical specifications are those valid for the computer that is provided by Kongsberg Maritime as a part of the SY50 system. For additional details, refer to the technical specifications provided by the manufacturer. Note This information was copied from the manufacturer’s documentation. To ensure that your information is correct, always consult the manufacturer’s own documents. Related topics Weights and outline dimensions, page 282 Technical specifications, page 274 Operating Panel weight and outline dimensions (Mk2) • Make and model: SY50 Operating Panel (Mk2) • Outline dimensions: – Depth: 183 mm – Width: 346 mm – Height: 123 mm • Weight: 3.7 kg Related topics Weights and outline dimensions, page 282 Technical specifications, page 274 Operating Panel weight and outline dimensions (Mk3) • Make and model: SY50 Operating Panel Mk3 • Outline dimensions: – Depth: 57 mm – Width: 225 mm – Height: 125 mm • Weight: 0.45 kg (Approximately) Related topics Weights and outline dimensions, page 282 Technical specifications, page 274 467020/B 283 Simrad SY50 Installation Manual Power Supply Unit weight and outline dimensions • Make and model: SY50 Power Supply Unit • Outline dimensions (including cable glands): – Depth: 219 mm – Width: 300 mm – Height: 438 mm • Weight: 12.5 kg Related topics Weights and outline dimensions, page 282 Technical specifications, page 274 Hull Unit weight and outline dimensions • Make: SY50 Hull Unit • Model: SY50 – Flange diameter: 343 mm – Number of holes in the flange: 8 – Total height: 1749* mm – Height above the installation trunk: 861 mm – Weight: 77 - 103 kg (Approximately) • Model: SY50C – Flange diameter: 343 mm – Number of holes in the flange: 8 – Total height: 1199* mm – Height above the installation trunk: 661 mm – Weight: 70 - 101 kg (Approximately) * The total height depends on the vessel specific installation properties. Related topics Weights and outline dimensions, page 282 Technical specifications, page 274 284 467020/B Technical specifications Environmental requirements These environmental specifications summarize the temperature and humidity requirements for the SY50 system. Topics Display environmental requirements, page 285 Nexcom NISE 3900E Processor Unit environmental requirements, page 285 Operating Panel environmental requirements (Mk2), page 286 Operating Panel environmental requirements (Mk3), page 286 Power Supply Unit environmental requirements, page 286 Hull Unit environmental requirements, page 287 Display environmental requirements Not applicable. The display is not a part of the SY50 scope of supply. It is not manufactured by Kongsberg Maritime. For more information, refer to the end-user documentation provided by the manufacturer. Related topics Environmental requirements, page 285 Technical specifications, page 274 Nexcom NISE 3900E Processor Unit environmental requirements • Manufacturer: Nexcom • Manufacturer’s website: https://www.nexcom.com • Model: Nexcom NISE 3900E • Operating temperature: -5 to 55 °C • Storage temperature: -20 to 80 °C • Relative humidity: 10 to 95% relative non-condensing • Certificates: – CE approval EN61000-6-2 – CE approval EN61000-6-4 467020/B 285 Simrad SY50 Installation Manual – FCC Class A • Ingress protection (IP) code: The manufacturer has not provided this information. The technical specifications are those valid for the computer that is provided by Kongsberg Maritime as a part of the SY50 system. For additional details, refer to the technical specifications provided by the manufacturer. Note This information was copied from the manufacturer’s documentation. To ensure that your information is correct, always consult the manufacturer’s own documents. Related topics Environmental requirements, page 285 Technical specifications, page 274 Operating Panel environmental requirements (Mk2) • Make and model: SY50 Operating Panel (Mk2) • Operating temperature: 0 to +50 °C • Storage temperature: -40 to 70 °C • Relative humidity: 5 to 95% relative, non-condensing Related topics Environmental requirements, page 285 Technical specifications, page 274 Operating Panel environmental requirements (Mk3) • Make and model: SY50 Operating Panel Mk3 • Operating temperature: 0 to +50 °C • Storage temperature: -40 to 70 °C • Relative humidity: 5 to 95% relative, non-condensing • Ingress protection (IP) code: IP65 Related topics Environmental requirements, page 285 Technical specifications, page 274 Power Supply Unit environmental requirements • Make and model: SY50 Power Supply Unit 286 467020/B Technical specifications • Operating temperature: 0 to +50 °C • Storage temperature: -40 to 70 °C • Relative humidity: 5 to 95% relative, non-condensing Related topics Environmental requirements, page 285 Technical specifications, page 274 Hull Unit environmental requirements • Make: SY50 Hull Unit • Model: SY50/SY50C – Operating temperature: 0 to +50 °C – Storage temperature: -20 to 40 °C – Relative humidity: 5 to 95% relative, non-condensing Note Do not expose the transducer to direct sunlight or excessive heat. Related topics Environmental requirements, page 285 Technical specifications, page 274 467020/B 287 Simrad SY50 Installation Manual Compass safe distance If you place any of the SY50 Fish-finding sonar units on the bridge, you must observe the physical distance to the compass. Topics Display compass safe distance, page 288 Nexcom NISE 3900E Processor Unit compass safe distance, page 288 Operating Panel compass safe distance (Mk2), page 289 Operating Panel compass safe distance (Mk3), page 289 Power Supply Unit compass safe distance, page 289 Hull Unit compass safe distance, page 290 Display compass safe distance Not applicable. The display is not a part of the SY50 scope of supply. It is not manufactured by Kongsberg Maritime. For more information, refer to the end-user documentation provided by the manufacturer. Related topics Compass safe distance, page 288 Technical specifications, page 274 Nexcom NISE 3900E Processor Unit compass safe distance • Manufacturer: Nexcom • Manufacturer’s website: https://www.nexcom.com • Model: Nexcom NISE 3900E • Standard compass: The manufacturer has not provided this information. • Other compass: 90The manufacturer has not provided this information. The technical specifications are those valid for the computer that is provided by Kongsberg Maritime as a part of the SY50 system. For additional details, refer to the technical specifications provided by the manufacturer. Note This information was copied from the manufacturer’s documentation. To ensure that your information is correct, always consult the manufacturer’s own documents. 288 467020/B Technical specifications Related topics Compass safe distance, page 288 Technical specifications, page 274 Operating Panel compass safe distance (Mk2) • Make and model: SY50 Operating Panel (Mk2) • Standard compass: 25 cm • Other compass: 16.5 cm Related topics Compass safe distance, page 288 Technical specifications, page 274 Operating Panel compass safe distance (Mk3) • Make and model: SY50 Operating Panel Mk3 • Standard compass: This information is currently not available. • Other compass: This information is currently not available. Related topics Compass safe distance, page 288 Technical specifications, page 274 Power Supply Unit compass safe distance • Make and model: SY50 Power Supply Unit • Compass safe distance: – Standard compass: 150 mm – Other compass: 94 mm • The specifications meet the requirements defined in the following standards: – IEC/EN 60945:2002 + Cor1:2008 – EN ISO 694:2001 Related topics Compass safe distance, page 288 Technical specifications, page 274 467020/B 289 Simrad SY50 Installation Manual Hull Unit compass safe distance • Make: SY50 Hull Unit • Compass safe distance: – Standard compass: 151 mm – Other compass: 90 mm • The specifications meet the requirements defined in the following standards: – IEC/EN 60945:2002 + Cor1:2008 – EN ISO 694:2001 Related topics Compass safe distance, page 288 Technical specifications, page 274 Minimum display requirements Unless specifically ordered, the SY50 system is not provided with a display. The display must then be purchased locally. You can use more than one display on your Processor Unit depending on personal and/or operational preferences. Note Make sure that the chosen display meets the requirements for the SY50 system. The design and construction must allow for marine use, and the display must be able to withstand the movements and vibrations normally experienced on a vessel. Verify that you have easy access to cables and connectors, and that the display can be installed in a safe and secure way. The minimum technical requirements for the display are: Resolution Minimum requirement: 1280 x 1024 pixels The visual quality of the presentation depends on the quality of your graphic adapter and display. We recommend that you use a large display with resolution 1920 x 1080 or 1920 x 1200. Video interface The video interface must match the output format(s) provided by the Processor Unit. The Processor Unit may offer video output on several formats. Investigate your options before you purchase a display. 290 467020/B Technical specifications Physical screen size The screen size depends on personal and/or operational preferences. We recommend that you use 24 inch or bigger diagonal screen size. The SY50 software supports 16:9 and 16:10 displays. 467020/B 291 Simrad SY50 Installation Manual Drawing file Topics About the drawings in the drawing file, page 293 Nexcom NISE 3900E Outline dimensions, page 294 462682 Power Supply Unit dimensions, page 296 462683 Hull Unit dimensions SY50, page 299 489609 Hull Unit dimensions SY50C, page 302 440475 Installation trunk dimensions, page 305 Optional units, page 308 292 467020/B Drawing file About the drawings in the drawing file Relevant drawings related to the installation and/or maintenance of the SY50 system are provided for information purposes only. Note These drawings are provided only for information and planning purposes. Information may be omitted. Observe the source drawings for additional details. The drawings are not to scale. Unless otherwise specified, all measurements are in millimetres. The original installation drawings are available in PDF and/or AutoCad's DWG format. The original drawing can be downloaded from our website. • www.kongsberg.com/simrad Some drawings and documents are not available from our website. These can be downloaded from the Simrad Dealer Club. • www.kongsberg.com/sdc The installation shipyard must provide all necessary design and installation drawings, as well as the relevant work standards and mounting procedures. If required, all documents provided by the shipyard for the physical installation of the SY50 system must be approved by the vessel’s national registry and corresponding maritime authority and/or classification society. Such approval must be obtained before the installation can begin. The shipowner and shipyard doing the installation are responsible for obtaining and paying for such approval. Related topics Drawing file, page 292 467020/B 293 Simrad SY50 Installation Manual Nexcom NISE 3900E Outline dimensions To obtain the source drawing, contact the manufacturer. 294 467020/B Drawing file Related topics Drawing file, page 292 Installing the Nexcom NISE 3900E Processor Unit, page 67 467020/B 295 Simrad SY50 Installation Manual 462682 Power Supply Unit dimensions Download the source drawing from our website: https://www.kongsberg.com/sy50 296 467020/B Drawing file 467020/B 297 Simrad SY50 Installation Manual Related topics Drawing file, page 292 Installing the Power Supply Unit, page 72 298 467020/B Drawing file 462683 Hull Unit dimensions SY50 Download the source drawing from our website: https://www.kongsberg.com/sy50 467020/B 299 Simrad SY50 Installation Manual 300 467020/B Drawing file Related topics Drawing file, page 292 Installing the hull unit, page 88 467020/B 301 Simrad SY50 Installation Manual 489609 Hull Unit dimensions SY50C Download the source drawing from our website: https://www.kongsberg.com/sy50 302 467020/B Drawing file 467020/B 303 Simrad SY50 Installation Manual Related topics Drawing file, page 292 Installing the hull unit, page 88 304 467020/B Drawing file 440475 Installation trunk dimensions Download the source drawing from our website: https://www.kongsberg.com/sy50 467020/B 305 Simrad SY50 Installation Manual 306 467020/B Drawing file Related topics Drawing file, page 292 467020/B 307 Simrad SY50 Installation Manual Optional units Topics 476352 Operating Panel dimensions (Mk3), page 309 440689 Operating Panel cut-out drawing( Mk2), page 312 443179 Operating Panel dimensions (Mk2), page 313 439594 Operating Panel adapter plate (Mk2), page 316 308 467020/B Drawing file 476352 Operating Panel dimensions (Mk3) Download the source drawing from our website: https://www.kongsberg.com/sy50 467020/B 309 Simrad SY50 Installation Manual 310 467020/B Drawing file Related topics Drawing file, page 292 Installing the Operating Panel (Mk3), page 71 467020/B 311 Simrad SY50 Installation Manual 440689 Operating Panel cut-out drawing( Mk2) Download the source drawing from our website: https://www.kongsberg.com/sy50. Related topics Drawing file, page 292 Installing the Operating Panel (Mk2), page 69 312 467020/B Drawing file 443179 Operating Panel dimensions (Mk2) Download the source drawing from our website: https://www.kongsberg.com/sy50. 467020/B 313 Simrad SY50 Installation Manual 314 467020/B Drawing file Related topics Drawing file, page 292 Installing the Operating Panel (Mk2), page 69 467020/B 315 Simrad SY50 Installation Manual 439594 Operating Panel adapter plate (Mk2) Download the source drawing from our website: https://www.kongsberg.com/sy50. 316 467020/B Drawing file Related topics Drawing file, page 292 Installing the Operating Panel (Mk2), page 69 467020/B 317 Simrad SY50 Installation Manual Index 1000Base-T Ethernet cable .......................................... 154 A about acoustic noise............................................. 56 ambient noise............................................. 60 cavitation.................................................. 59 comments ................................................. 12 constructive criticism.................................... 12 document downloads .................................... 12 electrical noise ...................................... 58, 61 feedback................................................... 12 flow noise ................................................. 59 installation drawings .............................. 11, 293 installation instructions ................................. 11 interference ............................................... 60 machinery noise.......................................... 58 online information ....................................... 12 propellers.................................................. 58 rattle noise ................................................ 60 registered trademarks.................................... 12 self noise .................................................. 58 serial lines............................................... 159 software version.......................................... 12 suggestions ............................................... 12 target audience ........................................... 11 this publication ........................................... 11 ac mains power requirements ............................................ 279 ac power cable ..................................................... 148 access requirements sonar room ................................................ 51 acoustic noise about ....................................................... 56 ambient noise............................................. 60 cavitation.................................................. 59 contributing factors ...................................... 56 electrical noise ...................................... 58, 61 flow noise ................................................. 59 hull unit location noise considerations ................ 49 interference ............................................... 60 machinery noise.......................................... 58 Measuring the noise in passive mode ............... 254 propellers.................................................. 58 rattle noise ................................................ 60 reverberation.............................................. 61 self noise .................................................. 58 sources..................................................... 56 adapter plate drawing.................................................. 316 air conditioning requirements sonar room ................................................ 52 alternative origin vessel coordinate system.............................. 201 ambient noise acoustic noise............................................. 60 approval 318 classification society..................................... 35 installation drawings ................ 11, 43, 80, 95, 293 assigning custom user settings ................................... 245 presentation modes .................................... 245 athwartship location hull unit ................................................... 49 attachment point sonar room ................................................ 54 auxiliary machinery acoustic noise............................................. 58 B B-Scan testing the receiver and transmitter channels................................................ 260 backup image creating .................................................. 268 restoring ................................................. 270 bearing assign function to rotary switches ................... 247 bilge pump requirement sonar room ................................................ 54 BITE (Built-In Test Equipment) testing the receiver and transmitter channels with the BITE B-Scan functionality ............... 260 BITE B-Scan testing the receiver and transmitter channels................................................ 260 bootable creating bootable USB flash drive ................... 271 Bottom reverberation....................................... 61 bridge cable plan ............................................... 128 bridge interconnection cables list ........................................................ 129 Built In Test Equipment testing the receiver and transmitter channels with the BITE B-Scan functionality ............... 260 buoy Setting up input from buoys, fish aggregating devices and other external objects ................. 234 C cable drawing ac power cable.......................................... 148 Ethernet cable RJ45 ................................... 154 RS-232 serial line ................................ 151–152 serial line used for synchronisation.................. 153 vessel ground ........................................... 150 cable installation prerequisites ............................................ 136 sonar room .............................................. 138 topside ................................................... 136 cable plan bridge .................................................... 128 Processor Unit.......................................... 128 467020/B Index sonar room .............................................. 130 topside ................................................... 128 cable specifications RS-232 ............................................ 151–152 serial line used for synchronization ................. 153 cables list of sonar room interconnection cables........... 131 list of topside interconnection cables................ 129 Making sure that all SY50 system cables are properly connected ................................... 174 requirements .............................................. 33 CAT5 Ethernet cable .......................................... 154 CAT5E Ethernet cable .......................................... 154 cavitation acoustic noise............................................. 59 classification society approval ................................................... 35 approval (installation drawings) .............. 11, 43, 80, 95, 293 classification society approval requirements .............................................. 35 Clear To Send used in synchronization ............................... 153 comments send us..................................................... 12 commercial cables description .............................................. 126 communication port setting up the parameters ............................. 219 communication requirements sonar room ................................................ 53 compass required item ............................................. 26 scope of supply........................................... 26 compass deviation requirements .............................................. 33 compass safe distance display ................................................... 288 technical specifications................................ 288 Compass Safe Distance (CSD) computer ................................................ 288 Hull Unit ................................................ 290 Operating Panel (Mk2)................................ 289 Operating Panel (Mk3)................................ 289 Power Supply Unit .................................... 289 Processor Unit.......................................... 288 competence requirements for installation personnel ............... 44 computer Compass Safe Distance (CSD)....................... 288 connectors......................................... 139–140 environmental requirements.......................... 285 installation ................................................ 67 outline dimensions..................................... 282 outline dimensions drawing .......................... 294 power requirements.................................... 279 visual inspection ....................................... 167 weight ................................................... 282 configuration Setting up the Operating Panel....................... 179 configuring Operating Panel .................................. 183, 186 sensor interface......................................... 228 467020/B connection Ethernet cable .......................................... 154 RS-232 serial cable .............................. 151–152 serial line used for synchronisation.................. 153 connections ac power cable.......................................... 148 control cable ............................................ 146 Making sure that all SY50 system cables are properly connected ................................... 174 power cable ............................................. 145 transducer cable ........................................ 147 vessel ground cable .................................... 150 connectors computer .......................................... 139–140 Operating Panel ........................................ 143 Processor Unit front panel ............................ 139 Processor Unit rear panel ............................. 140 considerations hull unit location and noise ............................. 49 constructive criticism send us..................................................... 12 consumables Tools, equipment and consumables required for installation............................................... 44 contributing factors acoustic noise............................................. 56 control cable connections ............................................. 146 coordinate system alternative origin ....................................... 201 origin .................................................... 201 vessel .................................................... 200 course gyro required item ............................................. 26 scope of supply........................................... 26 setting up the interface ................................ 225 crane sonar room ................................................ 54 creating backup image........................................... 268 bootable USB flash drive ............................. 271 CSD computer ................................................ 288 Hull Unit ................................................ 290 Operating Panel (Mk2)................................ 289 Operating Panel (Mk3)................................ 289 Power Supply Unit .................................... 289 Processor Unit.......................................... 288 CSD (compass safe distance) display ................................................... 288 technical specifications................................ 288 CTS (Clear to Send) used in synchronization ............................... 153 CTS (Clear To Send) interface ................................................. 157 synchronization .................................. 155, 157 cut-out Operating Panel cut-out dimensions drawing ................................................ 312 D (D)GPS optional item.............................................. 28 scope of supply........................................... 28 319 Simrad SY50 Installation Manual data defining the file and folder settings for data recording............................................... 240 decking sonar room requirement................................. 54 defining athwartship location of the hull unit................... 49 file and folder settings for data recording........... 240 fore and aft location of the hull unit................... 48 ship dimensions ........................................ 203 ship origin............................................... 203 description ambient noise............................................. 60 cavitation.................................................. 59 display ..................................................... 19 electrical noise ...................................... 58, 61 flow noise ................................................. 59 HullUnit ................................................... 21 Installation trunk .................................... 23, 25 interference ............................................... 60 machinery noise.......................................... 58 Operating Panel .......................................... 27 origin in the vessel coordinate system .............. 201 Power Supply Unit ...................................... 20 Processor Unit............................................ 20 Processor Unit front panel ............................ 139 Processor Unit rear panel ............................. 140 propellers.................................................. 58 rattle noise ................................................ 60 self noise .................................................. 58 system ..................................................... 16 Transducer ................................................ 22 vessel coordinate system.............................. 200 description reverberation.............................................. 61 Diagnostics dialog box Verifying system operation by means of the Diagnostics functionality............................ 256 diagram system ..................................................... 18 dimensional survey summary procedure.................................... 196 dimensions about ..................................................... 293 adapter plate ............................................ 316 computer ................................................ 282 computer outline dimensions drawing .............. 294 defining ship dimensions ............................. 203 display ................................................... 282 download.................................................. 43 Hull Unit ................................................ 284 hull unit SY50 .......................................... 299 hull unit SY50C ........................................ 302 installation trunk outline dimensions drawing ................................................ 305 Operating Panel (Mk2)................................ 283 Operating Panel (Mk3)................................ 283 Operating Panel outline dimensions drawing .......................................... 309, 313 Power Supply Unit .................................... 284 Power Supply Unit outline dimensions drawing ................................................ 296 Processor Unit.......................................... 282 Processor Unit outline dimensions drawing ........ 294 technical specifications................................ 282 320 display compass safe distance ................................. 288 description ................................................ 19 dimensions .............................................. 282 environmental requirements.......................... 285 installation ................................................ 66 minimum requirements ............................... 290 outline dimensions..................................... 282 power requirements.................................... 279 visual inspection ....................................... 165 weight ................................................... 282 docking requirements .............................................. 34 documents download from website ................................. 12 download documents from website ................................ 12 installation drawings .................................... 43 drawing ac power cable.......................................... 148 adapter plate ............................................ 316 computer outline dimensions......................... 294 display outline dimensions ........................... 282 Ethernet cable RJ45 ................................... 154 hull unit SY50 dimensions ........................... 299 hull unit SY50C dimensions ......................... 302 installation trunk outline dimensions................ 305 Operating Panel cut-out dimensions ................ 312 Operating Panel outline dimensions........... 309, 313 Power Supply Unit outline dimensions drawing ................................................ 296 Processor Unit outline dimensions .................. 294 RS-232 serial line cable......................... 151–152 serial line used for synchronisation.................. 153 vessel ground ........................................... 150 drawings about ..................................................... 293 approval ............................... 11, 43, 80, 95, 293 download.................................................. 43 installation ................................................ 11 responsibility ........................................ 11, 43 dry docking requirements .............................................. 34 E electrical installation requirements sonar room ................................................ 53 electrical noise acoustic noise........................................ 58, 61 environmental requirements ............................................ 285 environmental parameters change ................................................... 241 environmental requirements computer ................................................ 285 display ................................................... 285 Hull Unit ................................................ 287 Operating Panel (Mk2)................................ 286 Operating Panel (Mk3)................................ 286 Power Supply Unit .................................... 286 Processor Unit.......................................... 285 sonar room ................................................ 50 equipment 467020/B Index Tools, equipment and consumables required for installation............................................... 44 Ethernet cable specifications ........................................... 154 Ethernet port defining the communication port parameters ............................................. 219 external objects Setting up input from buoys, fish aggregating devices and other external objects ................. 234 F F1 F2 F3 assigning function ..................................... 248 FAD (Fish aggregating device) Setting up input from buoys, fish aggregating devices and other external objects ................. 234 familiarization hull unit ................................................... 93 feedback send us..................................................... 12 file locations defining the file and folder settings for data recording............................................... 240 file setup defining the file and folder settings for data recording............................................... 240 fish aggregating device (FAD) Setting up input from buoys, fish aggregating devices and other external objects ................. 234 flooring sonar room requirement................................. 54 flow noise acoustic noise............................................. 59 folder locations defining the file and folder settings for data recording............................................... 240 for and aft location hull unit ................................................... 48 fresh water changing environmental parameters................. 241 front panel description Processor Unit.......................................... 139 G gain assign function to rotary switches ................... 247 gantry mounting ................................................ 111 general safety rules ........................... 30, 42, 65, 91 global positioning system optional item.............................................. 28 scope of supply........................................... 28 Global positioning system (GPS) Setting up the input from a navigation system (GPS)................................................... 220 GPS optional item.............................................. 28 scope of supply........................................... 28 Setting up the input from a navigation system (GPS)................................................... 220 ground cable ..................................................... 150 467020/B grounding requirements sonar room ................................................ 53 gyro setting up the interface ................................ 225 H handling Rules for transducer handling ........... 15, 22, 45, 102 heading gyro setting up the interface ................................ 225 heading sensor required item ............................................. 26 scope of supply........................................... 26 heating requirements sonar room ................................................ 52 help support offices ............................................ 36 high voltage safety rules.................................. 30, 42, 65, 91 how to Checking the hull unit lowering and hoisting functionality/Bridge steps ........................... 252 how to Checking the hull unit lowering and hoisting functionality........................................... 251 Checking the hull unit lowering and hoisting functionality/Sonar room steps ..................... 253 Verifying system operation by means of the Diagnostics functionality............................ 256 how to Checking the environmental conditions in the sonar room ............................................ 173 Making sure that all SY50 system cables are properly connected ................................... 174 Setting up the input from a motion reference unit (MRU)............................................ 229 Setting up the Operating Panel....................... 179 Verifying the quality of the hull unit installation............................................. 122 how to Adjusting the built-in motion sensor offset ........ 210 Adjusting the stabilization offsets for the motion sensor ......................................... 213 assign custom user settings ........................... 245 assign functions to F1, F2 and F3 ................... 248 assign functions to rotary switches .................. 247 assign presentation modes ............................ 245 change the environmental parameters............... 241 configure the Operating Panel.................. 183, 186 configure the sensor interface ........................ 228 create a backup image on a USB flash drive ........ 268 create a bootable USB flash drive ................... 271 define athwartship location of the hull unit........... 49 define fore and aft location of the hull unit........... 48 define ship dimensions ................................ 203 define ship origin ...................................... 203 define the Ethernet (LAN) port parameters ........ 219 define the file and folder settings for data recording............................................... 240 define the serial port parameters ..................... 219 do a dimensional survey .............................. 196 do a visual inspection of the computer.............. 167 do a visual inspection of the display ................ 165 do a visual inspection of the hull unit ............... 171 321 Simrad SY50 Installation Manual do a visual inspection of the Operating Panel ................................................... 168 do a visual inspection of the Power Supply Unit..................................................... 170 do a visual inspection of the Processor Unit ........ 167 insert the installation parameters for the motion reference unit ......................................... 208 insert the installation parameters for the transducer.............................................. 205 install navigation and other sensors (summary) ............................................. 217 install sonar room cables.............................. 138 install the operational software ...................... 177 install topside cables................................... 136 Installing the display .................................... 66 Installing the Nexcom NISE 3900E Processor Unit....................................................... 67 Installing the Operating Panel (Mk2) ................. 69 Installing the Operating Panel (Mk3) ................. 71 Installing the Power Supply Unit ...................... 72 Installing the software license........................ 178 make a noise/speed curve to determine vessel noise.................................................... 264 makes sure that operating power is correct......... 176 measure noise at different speeds.................... 264 Measuring the noise in passive mode ............... 254 Mounting the installation trunk ........................ 83 Obtaining the software license ....................... 178 restore from a backup image on a USB flash drive .................................................... 270 save the current user settings ......................... 242 select measurement units ............................. 237 select menu language.................................. 242 select which operating panel to use ................. 244 set to work .............................................. 163 set up synchronization................................. 231 set up the gyro interface............................... 225 set up the Operating Panel ...................... 183, 186 set up the speed log interface......................... 223 Setting up input from buoys, fish aggregating devices and other external objects ................. 234 Setting up the input from a navigation system (GPS)................................................... 220 test the receiver and transmitter channels with the BITE B-Scan functionality ..................... 260 turn on the system for the first time ................. 190 Turning on the SY50 system for normal use ........ 193 unpack the transducer ................................. 102 verify the quality of the installation trunk mounting ................................................ 85 how to Mounting the gantry ................................... 111 Mounting the hull unit on top of the installation trunk.................................................... 116 Mounting the transducer flange ...................... 106 Mounting the trunk bearing .......................... 108 hull unit defining athwartship location........................... 49 defining fore and aft location........................... 48 familiarization ............................................ 93 main parts identification ................................ 93 mounting ................................................ 116 noise considerations ..................................... 49 physical location ......................................... 47 322 Verifying the quality of the hull unit installation............................................. 122 visual inspection ....................................... 171 Hull Unit Checking the hull unit lowering and hoisting functionality........................................... 251 Checking the hull unit lowering and hoisting functionality/Bridge steps ........................... 252 Checking the hull unit lowering and hoisting functionality/Sonar room steps ..................... 253 Compass Safe Distance (CSD)....................... 290 environmental requirements.......................... 287 outline dimensions..................................... 284 power consumption.................................... 281 power requirements.................................... 281 System Protection page ............................... 239 weight ................................................... 284 Hull Unit compass safe distance ........................ 290 Hull Unit environmental requirements................. 287 Hull Unit power requirements .......................... 281 hull unit SY50 dimensions .............................................. 299 outline dimensions..................................... 299 hull unit SY50C dimensions .............................................. 302 outline dimensions..................................... 302 Hull Unit weight and outline dimensions.............. 284 HullUnit description ................................................ 21 humidity requirements ............................................ 285 I identification hull unit main parts ...................................... 93 IEC line socket............................................... 148 image creating backup image ................................ 268 creating bootable USB flash drive ................... 271 restoring from a backup image....................... 270 important ..................................................... 14 Before you turn on the SY50 system.................. 14 If something breaks down .............................. 14 Manual operation of the hull unit...................... 14 Rules for transducer handling ........... 15, 22, 45, 102 Watertight integrity ...................................... 14 When the SY50 system is not used.................... 14 When you are docking your vessel .................... 14 When you want to turn off the SY50 system......... 14 information online ...................................................... 12 support .................................................... 36 inserting installation parameters for motion reference unit ..................................................... 208 installation parameters for the transducer .......... 205 inspection installation trunk mounting quality check ............ 85 visual inspection of the computer.................... 167 visual inspection of the display ...................... 165 visual inspection of the hull unit..................... 171 visual inspection of the Operating Panel ........... 168 visual inspection of the Power Supply Unit ........ 170 467020/B Index visual inspection of the Processor Unit ............. 167 installation computer .................................................. 67 display ..................................................... 66 drawings................................................... 11 instructions ............................................... 11 Operating Panel (Mk2).................................. 69 Operating Panel (Mk3).................................. 71 Power Supply Unit ...................................... 72 Processor Unit............................................ 67 requirements for installation personnel ............... 44 software ................................................. 177 software license ........................................ 178 summary .................................................. 40 installation drawings about ................................................. 11, 293 approval ............................... 11, 43, 80, 95, 293 download.................................................. 43 responsibility ........................................ 11, 43 installation instructions about ....................................................... 11 responsibility ........................................ 11, 43 installation of cables prerequisites ............................................ 136 installation requirements environmental .......................................... 285 humidity................................................. 285 temperature ............................................. 285 Installation summary ....................................... 40 installation trunk mounting .................................................. 83 outline dimensions drawing .......................... 305 quality check ............................................. 85 Installation trunk description ........................................... 23, 25 installing sonar room cables...................................... 138 topside cables........................................... 136 instructions installation ................................................ 11 insulation requirements sonar room ................................................ 52 intercom requirements sonar room ................................................ 53 interface setting up the gyro interface .......................... 225 setting up the speed log interface .................... 223 using RS-232 serial line............................... 157 interfaces computer .......................................... 139–140 Processor Unit front panel ............................ 139 Processor Unit rear panel ............................. 140 interfacing a course gyro Sensor Installation page............................... 225 interfacing a gyro Sensor Installation page............................... 225 interfacing a heading gyro Sensor Installation page............................... 225 interfacing a navigation sensor summary ................................................ 217 interfacing a speed log Sensor Installation page............................... 223 interference acoustic noise............................................. 60 electrical noise ...................................... 58, 61 467020/B internet network security ......................................... 35 introduction sonar room ................................................ 50 K K-Sync synchronization using RS-232 serial line........... 155 Kongsberg Maritime support .................................................... 36 L LAN port defining the communication port parameters ............................................. 219 language select..................................................... 242 LCD monitor environmental requirements.......................... 285 power requirements.................................... 279 lifting device sonar room ................................................ 54 lifting requirements sonar room ................................................ 54 light requirements sonar room ................................................ 53 line socket IEC....................................................... 148 list sonar room interconnection cables .................. 131 topside interconnection cables ....................... 129 location athwartship location of the hull unit................... 49 fore and aft location of the hull unit................... 48 hull unit ................................................... 47 logo registered trademark..................................... 12 M machinery noise acoustic noise............................................. 58 main engine acoustic noise............................................. 58 main parts identification hull unit ................................................... 93 mains power cable ..................................................... 148 making sure that operating power is correct ........ 176 requirements ............................................ 279 maritime authority approval (installation drawings) .............. 11, 43, 80, 95, 293 master setting up synchronization ............................ 231 Master SynchronizationDelay................................. 233 SynchronizationMode ................................. 233 measurement units selecting ................................................. 237 measuring 323 Simrad SY50 Installation Manual noise at different speeds .............................. 264 mechanical drawings about ..................................................... 293 download.................................................. 43 menu language select..................................................... 242 minimum requirements display ................................................... 290 monitor environmental requirements.......................... 285 power requirements.................................... 279 motion reference unit inserting installation parameters ..................... 208 Motion Reference Unit Setting up the input from a motion reference unit (MRU)............................................ 229 motion sensor Adjusting the built-in motion sensor offset ........ 210 motion sensorAdjusting the stabilization offsets for the motion sensor mounting ................................................ 213 mounting installation trunk ......................................... 83 MRU inserting installation parameters ..................... 208 N navigation sensor installing navigation and other sensors (summary) ............................................. 217 network security ............................................ 35 Nexcom NISE 3900E Compass Safe Distance (CSD)....................... 288 dimensions .............................................. 282 environmental requirements.......................... 285 power consumption.................................... 279 power requirements.................................... 279 weight ................................................... 282 Nexcom NISE 3900E Processor Unit installation ................................................ 67 Nexcom NISE 3900E Processor Unit compass safe distance.............................................. 288 Nexcom NISE 3900E Processor Unit environmental requirements ........................... 285 Nexcom NISE 3900E Processor Unit power requirements ............................................. 279 Nexcom NISE 3900E Processor Unit weight and outline dimensions ...................................... 282 noise about acoustic noise ..................................... 56 ambient noise............................................. 60 cavitation.................................................. 59 contributing factors ...................................... 56 electrical noise ...................................... 58, 61 flow noise ................................................. 59 interference ............................................... 60 machinery noise.......................................... 58 making a noise/speed curve to determine vessel noise.................................................... 264 measuring ............................................... 264 Measuring the noise in passive mode ............... 254 propeller noise............................................ 58 rattle noise ................................................ 60 self noise .................................................. 58 324 noise considerations hull unit location ......................................... 49 noise sources ................................................ 56 Noise sources requirements .............................................. 34 noise/speed curve making .................................................. 264 O obtaining software license ........................................ 178 offices support .................................................... 36 Offset motion sensor........................................... 213 online information ............................................... 12 operating panel assigning custom user settings ....................... 245 assigning functions to F1, F2 and F3................ 248 assigning functions to rotary switches .............. 247 assigning presentation modes ........................ 245 selecting which operating panel to use.............. 244 Operating Panel configuring........................................ 183, 186 connectors............................................... 143 cut-out dimensions drawing .......................... 312 description ................................................ 27 outline dimensions drawing .................... 309, 313 setting up.......................................... 183, 186 Setting up the Operating Panel....................... 179 supported................................... 27, 69, 71, 244 visual inspection ....................................... 168 Operating Panel (Mk2 mounting .................................................. 69 Operating Panel (Mk2) Compass Safe Distance (CSD)....................... 289 environmental requirements.......................... 286 installation ................................................ 69 outline dimensions..................................... 283 power consumption.................................... 280 power requirements.................................... 280 weight ................................................... 283 Operating Panel (Mk3) Compass Safe Distance (CSD)....................... 289 environmental requirements.......................... 286 installation ................................................ 71 mounting .................................................. 71 outline dimensions..................................... 283 power requirements.................................... 280 weight (Mk3) ........................................... 283 Operating Panel compass safe distance (Mk2) ........ 289 Operating Panel compass safe distance (Mk3) ........ 289 Operating Panel environmental requirements (Mk2) ..................................................... 286 Operating Panel environmental requirements (Mk3) ..................................................... 286 Operating Panel power requirements (Mk2) .......... 280 Operating Panel power requirements (Mk3) .......... 280 Operating Panel weight and outline dimensions (Mk2) ..................................................... 283 Operating Panel weight and outline dimensions (Mk3) ..................................................... 283 operating power 467020/B Index making sure it is correct............................... 176 operating voltage computer ................................................ 279 display ................................................... 279 Hull Unit ................................................ 281 Operating Panel (Mk2)................................ 280 Operating Panel (Mk3)................................ 280 Power Supply Unit .................................... 280 Processor Unit.......................................... 279 operational software installation .............................................. 177 optional item global positioning system............................... 28 origin defining ship origin .................................... 203 vessel coordinate system.............................. 201 outline dimensions about ..................................................... 293 computer ................................................ 282 display ................................................... 282 download.................................................. 43 Hull Unit ................................................ 284 hull unit SY50 .......................................... 299 hull unit SY50C ........................................ 302 Operating Panel (Mk2)................................ 283 Operating Panel (Mk3)................................ 283 Power Supply Unit .................................... 284 Processor Unit.......................................... 282 technical specifications................................ 282 outline dimensions drawing computer ................................................ 294 installation trunk ....................................... 305 Operating Panel .................................. 309, 313 Power Supply Unit .................................... 296 Processor Unit.......................................... 294 overview installation ................................................ 40 sonar room ................................................ 50 P parts identification hull unit ................................................... 93 performance specifications ........................................... 275 personnel skills requirements for installation............................ 44 physical location hull unit ................................................... 47 plugs computer .......................................... 139–140 power requirements ............................................ 279 power cable connections ............................................. 145 specifications ........................................... 145 power consumption computer ................................................ 279 Hull Unit ................................................ 281 Operating Panel (Mk2)................................ 280 Power Supply Unit .................................... 280 Processor Unit.......................................... 279 power requirements computer ................................................ 279 display ................................................... 279 467020/B Hull Unit ................................................ 281 Operating Panel (Mk2)................................ 280 Operating Panel (Mk3)................................ 280 Power Supply Unit .................................... 280 Processor Unit.......................................... 279 sonar room ................................................ 53 power supply making sure that operating power is correct ........ 176 Power Supply Unit Compass Safe Distance (CSD)....................... 289 description ................................................ 20 environmental requirements.......................... 286 installation ................................................ 72 outline dimensions..................................... 284 outline dimensions drawing .......................... 296 power consumption.................................... 280 power requirements.................................... 280 visual inspection ....................................... 170 weight ................................................... 284 Power Supply Unit compass safe distance ............ 289 Power Supply Unit environmental requirements ............................................. 286 Power Supply Unit power requirements ............... 280 Power Supply Unit weight and outline dimensions ............................................... 284 prerequisites cable installation ....................................... 136 presentation modes assigning ................................................ 245 procedure Checking the hull unit lowering and hoisting functionality/Bridge steps ........................... 252 procedure Checking the hull unit lowering and hoisting functionality........................................... 251 Checking the hull unit lowering and hoisting functionality/Sonar room steps ..................... 253 Verifying system operation by means of the Diagnostics functionality............................ 256 procedure Checking the environmental conditions in the sonar room ............................................ 173 Making sure that all SY50 system cables are properly connected ................................... 174 Setting up the input from a motion reference unit (MRU)............................................ 229 Setting up the Operating Panel....................... 179 Verifying the quality of the hull unit installation............................................. 122 procedure Adjusting the built-in motion sensor offset ........ 210 Adjusting the stabilization offsets for the motion sensor ......................................... 213 assigning custom user settings ....................... 245 assigning functions to F1, F2 and F3................ 248 assigning functions to rotary switches .............. 247 assigning presentation modes ........................ 245 changing the environmental parameters ............ 241 configuring the Operating Panel ............... 183, 186 configuring the sensor interface...................... 228 creating a backup image on a USB flash drive .................................................... 268 creating a bootable USB flash drive................. 271 defining athwartship location of the hull unit ........ 49 defining fore and aft location of the hull unit ........ 48 325 Simrad SY50 Installation Manual defining ship dimensions ............................. 203 defining ship origin .................................... 203 defining the Ethernet (LAN) port parameters ............................................. 219 defining the file and folder settings for data recording............................................... 240 defining the serial port parameters................... 219 doing a dimensional survey .......................... 196 inserting the installation parameters for the motion reference unit ................................ 208 inserting the installation parameters for the transducer.............................................. 205 installing navigation and other sensors (summary) ............................................. 217 installing sonar room cables.......................... 138 Installing the display .................................... 66 Installing the Nexcom NISE 3900E Processor Unit....................................................... 67 Installing the Operating Panel (Mk2) ................. 69 Installing the Operating Panel (Mk3) ................. 71 installing the operational software................... 177 Installing the Power Supply Unit ...................... 72 Installing the software license........................ 178 installing topside cables............................... 136 making a noise/speed curve to determine vessel noise.................................................... 264 making sure that operating power is correct ........ 176 measuring noise at different speeds ................. 264 Measuring the noise in passive mode ............... 254 Mounting the installation trunk ........................ 83 Obtaining the software license ....................... 178 restoring from a backup image on a USB flash drive .................................................... 270 saving the current user settings ...................... 242 selecting measurement units.......................... 237 selecting menu language .............................. 242 selecting which operating panel to use.............. 244 setting to work ......................................... 163 Setting up input from buoys, fish aggregating devices and other external objects ................. 234 setting up synchronization ............................ 231 setting up the gyro interface .......................... 225 Setting up the input from a navigation system (GPS)................................................... 220 setting up the Operating Panel ................. 183, 186 setting up the speed log interface .................... 223 testing the receiver and transmitter channels with the BITE B-Scan functionality ............... 260 Turning on the SY50 system for normal use ........ 193 turning on the system for the first time ............. 190 unpacking the transducer ............................. 102 verifying the quality of the installation trunk mounting ................................................ 85 visual inspection of the computer.................... 167 visual inspection of the display ...................... 165 visual inspection of the hull unit..................... 171 visual inspection of the Operating Panel ........... 168 visual inspection of the Power Supply Unit ........ 170 visual inspection of the Processor Unit ............. 167 procedure Mounting the gantry ................................... 111 Mounting the hull unit on top of the installation trunk.................................................... 116 Mounting the transducer flange ...................... 106 Mounting the trunk bearing .......................... 108 326 Processor Unit cable plan ............................................... 128 Compass Safe Distance (CSD)....................... 288 description ................................................ 20 environmental requirements.......................... 285 front panel description ................................ 139 installation ................................................ 67 outline dimensions..................................... 282 outline dimensions drawing .......................... 294 power requirements.................................... 279 rear panel description.................................. 140 visual inspection ....................................... 167 weight ................................................... 282 propellers acoustic noise............................................. 58 pump sonar room requirement................................. 54 pump requirement sonar room ................................................ 54 purpose sonar room ................................................ 50 this publication ........................................... 11 Q quality check installation trunk mounting ............................. 85 R range assign function to rotary switches ................... 247 rattle noise acoustic noise............................................. 60 rear panel description Processor Unit.......................................... 140 record defining the file and folder settings for data recording............................................... 240 registered trademarks....................................... 12 Request To Send used in synchronization ............................... 153 required item compass ................................................... 26 course gyro ............................................... 26 heading sensor............................................ 26 speed log .................................................. 26 uninterruptible power supply........................... 27 required tool Tools, equipment and consumables required for installation............................................... 44 requirement skills of installation personnel ......................... 44 requirements ac mains power......................................... 279 classification society approval ......................... 35 compass deviation ....................................... 33 dry docking ............................................... 34 environmental .......................................... 285 humidity................................................. 285 mains power ............................................ 279 Noise sources............................................. 34 power .................................................... 279 supply power ........................................... 279 467020/B Index supply voltage ............................................ 32 temperature ............................................. 285 uninterruptible power supply........................... 32 requirementscables ......................................... 33 requirementswiring ......................................... 33 responsibility installation drawings ............................... 11, 43 installation instructions ............................ 11, 43 restoring backup image........................................... 270 reverberation description ............................................... 61 RJ45 Ethernet cable .......................................... 154 rotary switches assigning functions .............................. 244, 247 RS-232 about ..................................................... 159 cable specifications .............................. 151–152 interface ................................................. 157 serial line cable................................... 151–152 synchronization .................................. 155, 157 RS-422e about ..................................................... 159 RS-485 about ..................................................... 159 RTS (Request to Send) used in synchronization ............................... 153 RTS (Request To Send) interface ................................................. 157 synchronization .................................. 155, 157 S safety rules high voltage................................. 30, 42, 65, 91 salinity changing environmental parameters................. 241 salt water changing environmental parameters................. 241 saving current user settings ................................... 242 scope of supply.............................................. 29 compass ................................................... 26 course gyro ............................................... 26 global positioning system............................... 28 heading sensor............................................ 26 speed log .................................................. 26 uninterruptible power supply........................... 27 security network.................................................... 35 select which operating panel to use ......................... 244 selecting measurement units ..................................... 237 self noise acoustic noise............................................. 58 sensor configuring.............................................. 228 Sensor Configuration page configuring the sensor interface...................... 228 Sensor Installation page installing navigation and other sensors (summary) ............................................. 217 interfacing a course gyro.............................. 225 467020/B interfacing a speed log ................................ 223 serial line about ..................................................... 159 cable specifications serial line used for synchronization ....................................... 153 RS-232 cable specifications .................... 151–152 serial line used for synchronization cable specifications .................................... 153 serial port defining the communication port parameters ............................................. 219 setting to work procedures .............................................. 163 setting up Operating Panel .................................. 183, 186 Setting up the input from a motion reference unit (MRU) .................................................... 229 settings saving the current user settings ...................... 242 setup select menu language.................................. 242 ship dimensions defining.................................................. 203 ship origin defining.................................................. 203 shipyard cables description .............................................. 126 Simrad registered trademark..................................... 12 support .................................................... 36 SIMRAD registered trademark..................................... 12 size adapter plate ............................................ 316 computer ................................................ 282 display ................................................... 282 Hull Unit ................................................ 284 hull unit SY50 .......................................... 299 hull unit SY50C ........................................ 302 installation trunk outline dimensions................ 305 Operating Panel (Mk2)................................ 283 Operating Panel (Mk3)................................ 283 Operating Panel cut-out dimensions ................ 312 Power Supply Unit .................................... 284 Processor Unit.......................................... 282 technical specifications................................ 282 size requirements sonar room ................................................ 51 skills requirements for installation personnel ............... 44 slave setting up synchronization ............................ 231 Slave SynchronizationDelay................................. 234 SynchronizationMode ................................. 233 sockets computer .......................................... 139–140 software installation .............................................. 177 version..................................................... 12 software license installation .............................................. 178 obtaining ................................................ 178 sonar room access requirements ..................................... 51 327 Simrad SY50 Installation Manual attachment point ......................................... 54 bilge pump requirement................................. 54 cable plan ............................................... 130 Checking the environmental conditions in the sonar room ............................................ 173 communication requirements .......................... 53 crane ....................................................... 54 decking requirement..................................... 54 electrical installation requirements .................... 53 environmental requirements............................ 50 grounding requirements................................. 53 heating requirements .................................... 52 insulation requirements ................................. 52 introduction ............................................... 50 lifting device.............................................. 54 lifting requirements...................................... 54 light requirements........................................ 53 overview .................................................. 50 power requirements...................................... 53 purpose .................................................... 50 size requirements ........................................ 51 ventilation requirements ................................ 52 Verifying the quality of the hull unit installation............................................. 122 watertight integrity ...................................... 51 sonar room cables installing ................................................ 138 sonar room interconnection cables list ........................................................ 131 sound speed changing environmental parameters................. 241 specifications ac power cable.......................................... 148 compass safe distance ................................. 288 Ethernet cable RJ45 ................................... 154 outline dimensions..................................... 282 performance ............................................ 275 power cable ............................................. 145 RS-232 serial line cable......................... 151–152 serial line used for synchronization ................. 153 technical................................................. 275 vessel ground cable .................................... 150 specifications weight ................................................... 282 speed measuring noise ........................................ 264 speed log required item ............................................. 26 scope of supply........................................... 26 setting up the interface ................................ 223 Stand-alone SynchronizationDelay................................. 233 SynchronizationMode ................................. 233 standards serial line................................................ 159 start-up turning on the system for the first time ............. 190 suggestions send us..................................................... 12 summary dimensional survey procedure ....................... 196 installation ................................................ 40 supply power requirements ........................................ 32, 279 supply voltage 328 computer ................................................ 279 display ................................................... 279 Hull Unit ................................................ 281 Operating Panel (Mk2)................................ 280 Operating Panel (Mk3)................................ 280 Power Supply Unit .................................... 280 Processor Unit.......................................... 279 requirements .............................................. 32 support information......................................... 36 Surface reverberation....................................... 61 survey summary procedure for dimensional survey ........ 196 synchronisation serial line used for synchronisation.................. 153 synchronization setting up................................................ 231 specifications serial line............................... 153 using RS-232 serial line......................... 155, 157 system description ................................................ 16 diagram.................................................... 18 turning on the system for the first time ............. 190 system cables description .............................................. 126 list of sonar room interconnection cables........... 131 list of topside interconnection cables................ 129 system software installation .............................................. 177 T target audience this publication ........................................... 11 technical specifications ........................................... 275 technical requirements ac mains power......................................... 279 mains power ............................................ 279 power .................................................... 279 supply power ........................................... 279 technical specifications compass safe distance ................................. 288 performance ............................................ 275 technical specifications outline dimensions..................................... 282 weight ................................................... 282 technical support offices...................................................... 36 telephone requirements sonar room ................................................ 53 temperature changing environmental parameters................. 241 requirements ............................................ 285 this publication about ....................................................... 11 purpose .................................................... 11 target audience ........................................... 11 this user manual about ....................................................... 11 purpose .................................................... 11 target audience ........................................... 11 tools Tools, equipment and consumables required for installation............................................... 44 topside 467020/B Index cable plan ............................................... 128 topside cables installing ................................................ 136 topside interconnection cables list ........................................................ 129 trademarks registered.................................................. 12 transducer inserting the installation parameters................. 205 Rules for transducer handling ........... 15, 22, 45, 102 unpacking ............................................... 102 Transducer description ................................................ 22 System Protection page ............................... 238 transducer cable connections ............................................. 147 transducer flange mounting ................................................ 106 trunk outline dimensions drawing .......................... 305 trunk bearing mounting ................................................ 108 turning on .................................................. 193 system for the first time ............................... 190 Tx Inhibit Hull Unit Position System Protection page ............................... 238 Tx Inhibit Operation Mode System Protection page ............................... 239 U uninterruptible power supply required item ............................................. 27 requirements .............................................. 32 scope of supply........................................... 27 units selecting measurement units.......................... 237 unpacking transducer ............................................... 102 UPS required item ............................................. 27 requirements .............................................. 32 scope of supply........................................... 27 USB flash drive creating a backup image .............................. 268 creating bootable....................................... 271 restoring from a backup image....................... 270 user interface select language ......................................... 242 user settings assigning ................................................ 245 save ...................................................... 242 vessel noise making a noise/speed curve .......................... 264 visual inspection display ................................................... 165 visual inspection of the computer.................... 167 visual inspection of the hull unit..................... 171 visual inspection of the Operating Panel ........... 168 visual inspection of the Power Supply Unit ........ 170 visual inspection of the Processor Unit ............. 167 Volume reverberation ...................................... 61 W water pump sonar room requirement................................. 54 water temperature changing environmental parameters................. 241 watertight integrity sonar room ................................................ 51 website download documents .................................... 12 weight computer ................................................ 282 display ................................................... 282 Hull Unit ................................................ 284 Operating Panel (Mk2)................................ 283 Operating Panel (Mk3)................................ 283 Power Supply Unit .................................... 284 Processor Unit.......................................... 282 weight technical specifications................................ 282 wiring list of sonar room interconnection cables........... 131 list of topside interconnection cables................ 129 prerequisites ............................................ 136 requirements .............................................. 33 wiring diagram bridge .................................................... 128 Processor Unit.......................................... 128 sonar room .............................................. 130 topside ................................................... 128 worker skills requirements for installation............................ 44 Y yyy .......................................................... 280 V ventilation requirements sonar room ................................................ 52 version software ................................................... 12 vessel coordinate system alternative origin ....................................... 201 origin .................................................... 201 principles................................................ 200 vessel ground cable ..................................................... 150 467020/B 329 ©2022 Kongsberg Maritime ISBN 978-82-8066-209-5 Installation Manual Simrad SY50 ">
/
دانلود
فقط یک یادآوری دوستانه. می توانید سند را درست در اینجا مشاهده کنید. اما مهمتر از همه، هوش مصنوعی ما قبلاً آن را خوانده است. این می تواند موارد پیچیده را به زبان ساده توضیح دهد، به سوالات شما به هر زبانی پاسخ دهد و به شما کمک کند به سرعت حتی طولانی ترین یا پیچیده ترین اسناد را پیمایش کنید.
تبلیغات