YASKAWA iQpump1000 Quick Start Manual
PDF
Документ
Реклама
Реклама
iQpump1000 AC Drive Intelligent Pump Controller Quick Start Guide Type: CIMR-PW A Models: 200 V Class: 3/4 to 175 HP ND 400 V Class: 3/4 to 500 HP ND 600 V Class: 2 to 250 HP ND To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual. MANUAL NO. TOEP YAIP1W 01A This Page Intentionally Blank 2 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide u Simple Setup Procedure This procedure is a supplement to other documentation supplied with this equipment and guides the user in properly wiring the iQpump and motor. It also shows the configuration for a simplex pump application. WARNING! Read and adhere to all safety messages contained in this manual prior to performing this procedure. When installing the system be sure to follow good wiring practices and all applicable codes. Ensure that the mounting of the various components are secure and that the environment, such as extreme dampness, poor ventilation etc. will not cause system degradation. Please read this cheat sheet and other documentation provided with the iQpump thoroughly before attempting any installation. The setup procedure begins on the next page. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3 Step iQpump Model Identification and Mounting 1 To make sure you received the correct model, it is essential to verify the iQpump nameplate with your order and make sure the iQpump has the correct rating so it can be used with your motor. Please check the nameplate information as shown in the example below. Drive Spec Number Drive Model Number Input Power Rating CIMR-PW2A0021FAA CC : CIMR-PW2A0021FAA Output Power Rating Weight Serial Number Normal Duty Amps 8000 6W3050 - 2 - 100 J0073D207410100 Software Version UL File Number Step 2 DANGER; LETHAL VOLTAGES ARE PRESENT - Before ! applying power to the iQpump, ensure that the terminal cover is fastened and all wiring connections are secure. After the power has been turned OFF, wait at least five minutes until the charge indicator extinguishes completely before touching any wiring, circuit boards or components. WARNING DO NOT CONNECT ANY OF THE FOLLOWING TERMINALS TO EARTH GROUND B1 In the case of systems with more than one iQpump, follow the above procedure for each iQpump and motor. The clearances to be maintained around the enclosure for adequate ventilation. The environmental specifications such as avoiding excessive dampness, extreme temperatures, chemical exposure, corrosive areas, etc. to avoid damage to the equipment and to maintain safety. - B2 +1 +2 +3 Real-time Clock Setup This step shows how to setup the iQpump real-time clock for first use. Note: If clock is not set the drive can still be programmed and operated, but ALM light will flash every 30s and showing Clock Not Set message. Power up the drive and set the real-time Clock. The real-time Clock setup screen will appear at first power up. Press to set the clock. Note: After the real-time clock is set the real-time clock setup screen will not show again unless parameter o4-17 is set to “Set”. DC Bus terminals location varies by model. Mounting the iQpump 3 Fig.1 & 2 below show the electrical connections for the input power and motor terminals for various iQpump models. Select the proper diagram for the model you are installing (see Step 1). WITH POWER OFF make the appropriate connections. Make sure to follow good wiring practices and all applicable codes. Ensure that the equipment is grounded properly as shown in fig. 1 Check that the available power will meet the input power requirements. Ensure that the output power from the iQpump is compatible with the motor requirements. The mounting of the iQpump is extremely important regarding environment and accessibility. Depending on your system, there are various models available and the mounting dimensions (footprint) may be different. Because the mounting procedure is fairly extensive, it is beyond the scope of this document; Refer to the iQpump1000 Quick Start Guide (Document No. TOEPYAIP1W01) received with the iQpump, Section 2.2 Mechanical Installation. Match the model that you received and follow the procedure described in the manual to ensure a safe and functional installation. In cases where the system has more than one iQpump, refer to the proper clearances required for adequate ventilation. Please pay particular attention to: Step Connect Motor and Line Power (W/T3) (T/L3) (R/L1) (U/T1) (V/T2) (S/L2) Real-time Clock Setup Screen To change direction of motor rotation swap any two of the three motor leads. Connect to chassis ground Input Protection (Fuse or Circuit Breaker) L1 L2 L3 Connect frame to ground Use L1, L2 for Use L1, L2, L3 for 3Ø Induction 1Ø Input Power * 3Ø Input Power motor Fig. 1 Input Power and Output Motor Electrical Connections for Models: 2_0004 - 2_0056, 4_0002 - 4_0044 and 5_0003 - 50011 NOT USED Removing and Attaching the Terminal Cover BUS TERMINALS: DO NOT CONNECT TO GROUND Improper removal of the iQpump terminal cover as well as front cover can cause extensive damage to the iQpump. To avoid damage to these items, please pay particular attention to the iQpump1000 Quick Start Guide TOEPYAIP1W01 Section 3.5 Removing and Attaching the Terminal Cover. Use to move cursor to The left and (R/L1) (W/T3) (U/T1) (S/L2) cursor to the right (V/T2) (T/L3) To change direction of motor rotation swap any two of the three motor leads. Connect to chassis ground Input Protection (Fuse or Circuit Breaker) to move use to adjust. When date and time are set press NEMA 1 to save. L1 L2 L3 Connect frame to ground Use L1, L2 for Use L1, L2, L3 for 3Ø Induction 1Ø Input Power * 3Ø Input Power motor Fig. 2 Input Power and Output Motor Electrical Connections for Models: 2_0110 & Larger and 4_0058 & Larger * Make sure the iQpump has been properly sized for single phase input Open Chassis 4 power. For best performance, the drive input supply voltage must be equal to or greater than the motor rated voltage. Example: Jun 12th 2012, 7:35am Note: Do NOT adjust sec per month. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Step Selecting Start/Stop and Speed Method 4 This step shows how to connect control wiring and feedback signal to the iQpump. Before making any control connections MAKE SURE POWER TO THE iQpump IS TURNED OFF! Next remove the terminal cover to gain access to the control terminals. (Step 1.) SELECT START / STOP CONTROL METHOD b1-02 The iQpump is DEFAULT SETUP TO START /STOP FROM THE KEYPAD (digital operator). If this is the preferred start/stop method then continue to the feedback signal connection section. Please refer to the wiring diagram below to start/stop the iQpump using an external switch or contact. User Terminals S1 S2 S3 S4 S5 S6 S7 Run (FWD) S8 User Terminals SN SC SP Link Wiring Diagram: 2-Wire Control Use for maintained contacts S1 S2 S3 S4 S5 S6 S7 Start Switch Normally Open Stop Switch Normally Closed S8 SN SC SP Link Wiring Diagram: 3-Wire Control Use for momentary contacts Note: 3rd row of terminal board is shown here. To use 3-Wire Control first Initialize the iQpump using parameter A1-03 = 3330 (Refer to the Quick Start Guide TOEP YAIP 1W 01) FEEDBACK SIGNAL WIRING (TRANSDUCER) Note: 2nd row of terminal board is shown here. (Factory Default) Factory Installed 2-Wire, 4-20mA Transducer E(G) +V AC A1 A2 A3 FM AM AC RP AC 24V A1 A3 SN V Cable Shield Black: Output 4 – 20mA (2) DIN Type I Install link (AC-SN) when using transducer. Brown or Red: +Power (1) A2 Jumper located inside the drive on the terminal board Cable Type For use with 2-Wire, 4 – 20mA Transducer (Factory Default) nd Note: 2 row of terminal board is shown here. 3-Wire, 0-10V Transducer E(G) +V AC A1 A2 A3 FM AM AC RP AC 24V Set Jumper to use 0 – 10V Transducer A1 A3 V Blue or Black Common Signal (2) I A2 Black or White Output 0 – 10V (3) Brown or Red: +Power (1) For use with 3-Wire, 0 – 10V Transducer ! Jumper located inside the drive on the terminal board Important Note: Signal colors and numbering may vary depending on feedback device used, please consult feedback device manual. NOTE: It is beyond the scope of this document to program the iQpump drive for network communication control. Please refer to the refer to the iQpump1000 Quick Start Guide (Document . No. TOEPYAIP1W01) for this selection. . YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5 Step Changing Parameters and Monitoring the iQpump 5 This step shows how to access and modify an iQpump parameter as well as how to monitor iQpump signals such as output frequency and motor current. Make sure all protective covers have been re-attached and power is turned on. DO NOT RUN THE MOTOR. Step 6 Application Setup This step shows how to configure the iQpump for a dedicated pump application. Make sure all protective covers have been re-attached and power is turned on. DO NOT RUN THE MOTOR. Available iQpump Application Macro’s: Access Parameter Menu and Change Parameter Value Press two times until the digital operator shows the parameter menu. 6008 Constant Pressure Mode (PSI) Default 6009 Pump Down Level Mode(Ft) 6010 Geothermal Mode The factory default is setup for 6011 VTC Pressure Control Mode constant pressure PSI, only change if application different. 7770 General Purpose Mode Select Application 2X Select Digit Press two times until the digital operator shows the parameter menu. 2X 2X Inc./Dec. Selection Go to Next Digit 2X Select Digit Inc./Dec. Selection Inc./Dec. Selection Select Application Switch to Edit Mode Press Switch to Edit Mode Modify Value to select. Save New Value Enter Application Parameters Hold button for 3 sec. to go back to the main menu. Monitor Motor Frequency and Motor Current Hold button for 3 sec. to go back to the main menu. iQpump Digital Operator power-up state Output Frequency and Transducer Feedback can be monitored simultaneously. Use Press and 3X to select monitor signals. Select Parameter. simultaneously shows the monitor menu. Press Use to access monitor menu. to select monitor. Switch to Edit Mode Modify Value Save New Value Go Back to Main Menu Hold button for 3 sec. to go back to the main menu. Please refer to the iQpump Quick Start Manual, (Document No. TOEP YAIP 1W 01) on how to access other drive monitors. 6 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Step 7 iQpump Quick Setup Parameter Overview (Simplex) Parameter Value A1-06 Dependent on Initialization Mode E2-01 Drive Size Dependent Description Reference Application Selected Displays selected applications, see Step 6. Read-only cannot be modified Motor Rated Current Set to the motor nameplate full load amps. For submersible motors use service factor amps (SFA). Number of motor poles is used to show the correct E2-04 2 Number of Motor Poles motor RPM on the display Enter ’4’ for an 1800 RPM motor and ‘2’ for a 3600 RPM motor. System Scaling: Enter feedback device maximum: P1-03 145 Feedback Device Scaling Example: Enter 200 for pressure transducer with a maximum of 200 PSI at 20mA. Q1-01 0 Comments Setpoint 1 Set System Setpoint Confirm number of poles 2 Pole Motor = 3600 RPM 4 Pole Motor = 1800 RPM 6 Pole Motor = 1200 RPM 8 Pole Motor = 900 RPM Confirm feedback device scaling. (See Illustration 1) Set to system pressure When the iQpump is turned On and the feedback signal level (transducer) falls below this level, the It is mandatory to program the Start / Draw pump system will start after the time specified in P1- Down Level in order to use the sleep func- 05 (default 1 sec). tion. Programming the Start Level as an Absolute (See Illustration 2 and 3) Value. Start / Draw Down Level has to programmed to a positive value in order for the Start / Draw Down Level to be an absolute value. Example: Start / Draw Down Level P1-04 set to 50 PSI and delay time P1-05 set to 5 sec. Pump system will start when the pressure drops below 50 PSI for 5 sec. P1-04 0.0 PSI Start / Drawn Down Level Programming the Start Level as a Delta Level from the System Setpoint Start / Draw Down Level has to programmed to a negative value in order for the Start Level to be a delta value from the setpoint. Example: Start / Draw Down Level P1-04 set to –10 Use PSI with a system setpoint of 50 PSI and a delay time P1-05 set to 5 sec. Pump system will start when the pressure drops below 40 PSI (50 - 10) for to change the sign. 5 sec. Minimum speed (Hz) the pump motor has to operate P1-06 40.0 Hz Minimum Pump Speed at. Example: Base pump motor speed is 3600 RPM, Minimum pump frequency should be set to minimum speed is 2400 RPM. Set a value where the pump enters a no-flow minimum pump frequency to 40.0 Hz. (2400 ÷ 3600 condition. x 60 Hz = 40 Hz) P4-10 P5-04 0 Disabled 1 Enabled Auto Mode Operator Run Power Down Storage Stores the run status in the Auto mode when operating from digital operator (b1-02=0). 0: Disabled 1: Enabled Hand Key Enable / Disable Enables or disables the Hand Key on the digital operator. 0: Disabled 1: Enabled YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Recommended for use when Start/Stop command is from the keypad. (See Step 9) Hand Key on keypad. (See Step 10) 7 Step 7 iQpump Factory Defaults Overview (adjust certain settings specific to the application) No. Value b5-03 3.0 sec. Description PI Integral Time Reference Comments Caution: can cause instability if Decrease integral time to make iQpump more responsive. value is too low. Select what to do when the feedback device (transducer) fails or gets disconnected. b5-12 2 (Fault) PI Feedback Reference Missing Detection Selection 0: Disabled, continue running no message is displayed 1: Alarm, show warning on the keypad when the feedback device fails or is disconnected NOTE: Disable parameter b5-12 if no transducer is installed. 2: Fault, stop pump system when the feedback fails or is disconnected C1-01 20.0 sec. See Note Acceleration Time 1 C1-02 10.0 sec. See Note Deceleration Time 1 L5-01 L5-03 P1-06 5 20 sec. 40.0 Hz Number of Restart Attempts Maximum Restart Time After Fault Minimum Pump Frequency Time it takes to accelerate the pump motor from zero to maximum speed. NOTE: Factory default with Thrust Mode enabled is 12.0 sec, 20.0 sec when disabled. Adjusted depending on system performance Time it takes to decelerate the pump motor from maximum speed to zero. NOTE: Factory default with Thrust Mode enabled is 5.0 sec, 10.0 sec when disabled. Determines the number of times iQpump will perform an automatic restart on the faults listed in the comments column. iQpump System Protection Faults that can be setup to restart are Low Level Feedback, High Level Feedback, Transducer Loss, Not Maintaining Setpoint, Loss of Prime, Pump Over Cycle. Refer to parameters P4-07 and P4-08. The number of restart attempts is set by L5-01. If the restart fails (or is not attempted due to a continuing fault condition) iQpump waits the Maximum Restart Time After Fault, before attempting another restart. Ground Fault Output Phase Loss Input Phase Loss iQpump Overload Motor Overload Overtorque DC Bus Fuse Blown DC Bus Undervoltage DC Bus Overvoltage Overheat Example: Base pump motor speed is 3600 RPM, minimum speed is 2400 RPM. Set where the pump can produce the minimum pressure even at zero flow. Time it takes before the pump system goes to sleep when the selected signal level Adjust according to system requirements. P2-03 5 sec. P4-12 30.0 Hz Thrust Bearing Frequency Sets the frequency reference used when the thrust bearing function is active. A value of 0 disables this function. Primarily used for submersible pumps. Program P4-12 = 0.0 Hz to disable function when iQpump is used with a centrifugal pump. P4-17 0.2 Min Utility Start Delay When utility power is restored and P4-10 is enabled (1), iQpump waits the time specified in P4-11 before auto operation becomes active. Note: Only active when P4-10 is enabled (1) and operation (start/stop) is from the digital operator. (P2-01) falls below the specified sleep level (P2-02) P1-02 Feedback Unit 0: Inch of Water 1: PSI 2: GPM 3: Degrees Fahrenheit 4: CFM 5: CMH 6: Liters / Hr 7: Liters/Sec 8: Bar 9: Pascal 10: Degrees Celsius 11: Meter 12: Feet 13: Liters per Minute 14: cm per Minute 15: Inch Hg 25: No Unit P1-03 = 200.0 PSI Feedback Scaling Feedback Maximum 2 200 PSI Example: Delta Level (Negative Start Level) Example: Absolute Level (Positive Start Level) Start Level Delay (P1-05) (Example 5.0 sec.) SYSTEM STARTS WHEN PRESSURE SIGNAL FALLS BELOW 100 PSI 150 200 PSI Start Level Delay (P1-05) (Example 5.0 sec.) SYSTEM STARTS WHEN PRESSURE SIGNAL FALLS BELOW 100 PSI 150 Feedback Signal from pressure transducer (4 – 20 mA) 0 START / DRAW DOWN LEVEL START / DRAW DOWN LEVEL WAIT Start Delay System Setpoint (Example 150.0 PSI) System Units (P1-02) (Example PSI) Start Pump System Time Feedback Scaling (P1-03) (Example 200.0 PSI) Start / Draw Down Level (P1-04) (Example 100.0 PSI) Pressure SYSTEM FEEDBACK UNIT / FEEDBACK DEVICE SCALING Pressure 1 8 Overcurrent P1-06 should be set to the level Minimum speed (Hz) the pump motor has to operate at. minimum pump frequency to 40.0 Hz. (2400 ÷ 3600 x 60 Hz = 40 Hz) Sleep Delay Time -50.0 PSI Feedback Signal from pressure transducer (4 – 20 mA) WAIT Start Delay System Setpoint (Example 150.0 PSI) System Units (P1-02) (Example PSI) Start Pump System Time Feedback Scaling (P1-03) (Example 200.0 PSI) Start / Draw Down Level (P1-04) (Example -50.0 PSI, (150.0 – 50.0) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Step iQpump Factory Defaults Overview (adjust certain settings specific to the application) 7 3 SLEEP MODE (Example) Output Frequency 60 Hz SYSTEM GOES TO SLEEP WHEN PUMP MOTOR SPEED DROPS BELOW 40 Hz (2400 RPM for 3600 RPM Motor). Sleep Delay Time (P2-03) (Example 5.0 sec.) Minimum Speed P1-06 (Example 40.0 Hz) Output Frequency (pump motor speed) 0 Ramp or Coast to Stop, b1-02 Pump Running WAIT FOR PRESSURE TO FALL BELOW START / DRAW DOWN LEVEL (P1-04) Go to Sleep Time 4 PUMP SYSTEM FAULT SETUP The iQpump can display a ‘Setpoint Not Met’ fault when the iQpump is unable to maintain the programmed system setpoint due a problem with the pump system. Set P1-15 to the maximum allowed difference between setpoint and feedback level. FEEDBACK SIGNAL P1-11 P1-15 Max Setpoint Diff P1-11 Setpoint -LOP Tim SETPOINT 5 P1-16 SET-POINT NOT MET Time LOW/HIGH FEEDBACK LEVEL DETECTION iQpump continuously monitors the system feedback signal. To display a ‘ Low Feedback’ fault set the low feedback level parameter P1-08 to the minimum feedback level allowed for your system and to display a ‘High Feedback’ fault set the high feedback level parameter P1-11 to the maximum feedback level allowed. 6 PRE-CHARGE OPERATION This function is used when the pump system requires to be pre-charged before normal operation. Upon start the iQpump will run at a fixed speed for a specified time or until the feedback signal reaches a programmed level after which it will switch to auto mode operation. Feedback Pre-Charge Lvl. P4-01 Pre-Charge Completed Pre-Charge Freq. P4-02 0 Hz THRUST BEARING - SUBMERSIBLE MOTORS Thrust Acceleration Time P4-11 (Example 1.0 sec.) Thrust Bearing Frequency P4-12 (Example 30.0 Hz) Turn Off Thrust Bearing Function (Output Frequency Reached) l. Ti m e C1-01 Acceleration Time ce Ac P4 -0 4 When using a submersible motor in combination with the iQpump, it is recommended to use the Thrust Bearing function to prevent excess motor wear. To enable this function , enter the minimum motor frequency in parameter P4-11. Example: Minimum motor speed 1800 RPM, 1800 RPM ÷ 3600 RPM x 60.0 Hz = 30.0 Hz 8 Auto Operation P4-01 Pre-Charge Level: Specified feedback level to stop pre-charge operation P4-02 Pre-Charge Frequency: Set desired pre-charge speed P4-03 Pre-Charge Time: Specified maximum pre-charge operation time Output Frequency 7 Output Frequency Thrust Bearing Output Frequency Time Auto/Hand Operation AUTO OPERATION – POWER DOWN STORAGE Allows iQpump to automatically start after power failure when operated from keypad / digital operator. This function is recommended for use when operating the iQpump in remote / unmanned areas. Use parameter P4-10 to enable. When the iQpump is powered down while running , an internal run command will automatically be initiated upon power -up. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 9 Step 8 Step Pump Rotation and Feedback Signal Check In this step the motor is checked for proper direction and operation. This test is to be performed solely from the digital operator. Apply power to the iQpump after all the electrical connections have been made and protective covers have been re-attached. At this point, DO NOT RUN THE MOTOR, the Digital Operator should display as shown in Fig. 3. 9 Auto Mode Operation AUTO MODE The iQpump can be operated in AUTO mode when the following actions have been performed: All parameters are programmed Motor direction has been checked Auto Mode: Reference source selected in parameter b1-01 (See step 3) Auto Mode: Run source selected in parameter b1-02 (See Step 3) No alarm active Hand Mode Off LED is blinking when AUTO mode is active but AUTO Run Command is not active. Fig. 4: Digital Operator Fig. 3: Digital Operator Auto Mode Off Motor Rotation Test Next, push on the Digital Operator; the display should read Press the AUTO button to put the iQpump into AUTO mode. and the HAND LED should be ON. In AUTO mode the iQpump is capable of starting or stopping based on the Run Source Selection setting parameter b1-02. (See Step 3 Select Start/Stop Control Method) The setpoint used in AUTO mode is based on the Reference Source Selection setting parameter b1-01. (See Step 3 Select Speed Method) The motor should now be operating at in the correct direction of pump. Push on the Digital Operator; the display should read as in Fig. 3. Press to access Hand Speed. Use SET SYSTEM SETPOINT Next, press Hand Speed value. Press to change to save value. If the direction is not correct, then power down the iQpump and follow Instructions below. ! to access or modify the system setpoint that was entered using parameter Q1-01 System Setpoint in the iQpump Quick Setup Menu Next press to store setpoint and press to return to the main operation menu. DANGER After the power has been turned OFF, wait at least five minutes until the charge indicator extinguishes completely before touching any wiring, circuit boards or components. Use precaution, and refer to Fig.1 or 2, swap any two of the three output leads to the motor (U/T1, V/T2 and W/T3). After the wiring change, repeat Step 8 and recheck motor direction. Digital Operator turned off. Next, press the AUTO button to start the iQpump. Example: 80 PSI iQpump automatically starts in Auto Mode when the feedback signal level falls below the programmed level in parameter P1-04 for the specified time in P1-05. 145 PSI Start Level Delay (P1-05) (Example 5.0 sec.) Verify feedback on display (show keypad) matches mechanical pressure gauge. Refer to parameter P1-02 and P1-03, if the feedback device scaling or system units are incorrect. Start / Draw Down Level P1-04 WAIT 0 FEEDBACK SIGNAL LEVEL Feedback signal from pressure transducer (4 – 20 mA) Pressure FEEDBACK SIGNAL CHECK 10 to change the system setpoint. to select the digit and Use Start Delay Start Pump System System Setpoint (Example 80 PSI) Refer to Illustration 2 on Page 3 of 4 for additional information on the Start Level Function. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Step 10 Hand Mode Operation HAND MODE The iQpump can be operated in HAND mode when the following actions have been performed: All parameters are programmed Motor direction has been checked Press to access Hand Speed. Use to change Hand Speed value. Press to save value. Hand Speed from Analog Input (0 – 10V) Set parameter P5-01 ‘Hand Mode Ref.’ to ‘0’ to adjust the hand mode reference from an external 0 – 10V signal connected to terminal A1 and AC. 0 – 10V Connection +V AC A1 A2 + A3 FM AM AC RP AC 24V Cable Shield E(G) 0 ~ 10Vdc Sleep and Anti-No-Flow (ANF) Detection (P2-23, P2-24, P2-25) NOTE: Before adjusting Anti-No-Flow operation ensure your system is regulating satisfactory while operating under normal running conditions. If stable continue to Step 1 to verify no-flow/sleep operation. If unstable turn off the Anti-No-Flow function (P2-23 = 0.00%) and adjust the PI control parameters b5-02 and b5-03 to stabilize pump system. Refer to iQpump Quick Start Guide (Document No.TOEP YAIP 1W 01) for additional information. Once the system is stable, reenable the Anti-No-Flow function by setting P2-23 to 0.40% and continue to Step 1 to verify no-flow/sleep operation. Step 1: Verify system holds pressure by creating a no-flow situation (e.g. close off discharge valve). Step 2: Press OFF button on the digital operator, wait 1 min. until system stabilizes and verify system pressure feedback U1-91. If the pressure drops more than 3 PSI (U1-91) adjust P2-25 to the actual delta pressure drop plus 1 PSI. Example: Setpoint is 80 PSI, pressure feedback U1-91 shows 76 PSI, P2-25 should be 4 + 1 or 5 PSI. Note: This value should always be more than your start level (P1-04). If not, the system pressure is not holding and this needs to be corrected, or the pump system will continue to cycle on and off. Step 3: Run system in normal automatic operation with flow. Next check monitor U1-99 “ANF Timer” and verify that the value is incrementing and resetting back to zero continuously. If the value holds at 10 sec. (P2-24) increase P2-24 “Anti-No-Flow Detection Time” by increments of 5 sec. Repeat Step 3 each time P2-24 is adjusted. Step 4: Create a no-flow situation (e.g. close discharge valve) and monitor that U1-99 “ANF Timer” increments and holds at P2-24 time (value set in Step 3). Once the Anti-No-Flow timer expires the speed will reduce gradually until it reaches minimum pump speed (P1-06) where it will hold for 5 sec. (P2-03) before going to sleep. Step 5: Run system in normal automatic operation and verify sleep and wake-up operation until system performs satisfactory. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 11 This Page Intentionally Blank 12 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Table of Contents SIMPLE SETUP PROCEDURE........................................................................ 3 i. PREFACE & GENERAL SAFETY.................................................................. 19 i.1 Preface ....................................................................................................................... 20 Applicable Documentation....................................................................................................... 20 Symbols................................................................................................................................... 20 Terms and Abbreviations ........................................................................................................ 20 Trademarks ............................................................................................................................. 20 i.2 General Safety ........................................................................................................... 22 Supplemental Safety Information ............................................................................................ 22 Safety Messages..................................................................................................................... 23 General Application Precautions ............................................................................................. 25 Motor Application Precautions................................................................................................. 26 Drive Label Warning Example................................................................................................. 28 Warranty Information............................................................................................................... 28 1. RECEIVING .................................................................................................... 29 1.1 Model Number and Nameplate Check ..................................................................... 30 Nameplate ............................................................................................................................... 30 2. MECHANICAL INSTALLATION..................................................................... 33 2.1 Mechanical Installation ............................................................................................. 34 Installation Environment .......................................................................................................... 34 Installation Orientation and Spacing........................................................................................ 34 Transporting the Drive............................................................................................................. 36 HOA Keypad Remote Usage .................................................................................................. 36 Exterior and Mounting Dimensions ......................................................................................... 39 3. ELECTRICAL INSTALLATION ...................................................................... 73 3.1 Standard Connection Diagram................................................................................. 74 3.2 Main Circuit Connection Diagram............................................................................ 77 Three-Phase 200 V Class Models 2A0004 to 2A0081 Three-Phase 400 V Class Models 4A0002 to 4A0044 Three-Phase 600 V Class Models 5A0003 to 5A0032 .......................................................... 77 Three-Phase 200 V Class Models 2A0110, 2A0138 Three-Phase 400 V Class Models 4A0058, 4A0072 Three-Phase 600 V Class Models 5A0041, 5A0052 ............................................................. 77 Three-Phase 200 V Class Models 2A0169 to 2A0211 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 13 Table of Contents Three-Phase 400 V Class Models 4A0088 to 4A0139 Three-Phase 600 V Class Models 5A0062 to 5A0099 .................................................................... 78 Three-Phase 200 V Class Models 2A0250 to 2A0415 Three-Phase 400 V Class Models 4A0165 to 4A0675 Three-Phase 600 V Class Models 5A0125 to 5A0242 .................................................................... 78 Single-Phase Connections ................................................................................................................ 78 3.3 Terminal Cover ....................................................................................................................79 Models 2A0004 to 2A0081, 4A0002 to 4A0044, 5A0003 to 5A0032 (IP20/NEMA Type 1 Enclosure) ....................................................................................................... 79 Models 2A0110 to 2A0250, 4A0208 to 4A0675, and 5A0125 to 5A0242 (IP00/Open Type Enclosure) ........................................................................................................................................ 80 3.4 HOA Keypad and Front Cover............................................................................................81 Removing/Reattaching the HOA Keypad .......................................................................................... 81 Removing/Reattaching the Front Cover ............................................................................................ 81 3.5 Top Protective Cover ..........................................................................................................84 Removing the Top Protective Cover ................................................................................................. 84 Reattaching the Top Protective Cover .............................................................................................. 84 3.6 Main Circuit Wiring..............................................................................................................85 Factory Recommended Branch Circuit Protection ............................................................................ 85 Main Circuit Terminal Functions........................................................................................................ 85 Protecting Main Circuit Terminals ..................................................................................................... 86 Wire Gauges and Tightening Torque ................................................................................................ 87 Main Circuit Terminal and Motor Wiring ............................................................................................ 93 3.7 Control Circuit Wiring .........................................................................................................96 Control Circuit Terminal Block Functions .......................................................................................... 96 Terminal Configuration ...................................................................................................................... 98 Wiring the Control Circuit Terminal ................................................................................................... 99 3.8 Control I/O Connections ...................................................................................................101 Sinking/Sourcing Mode Switch for Digital Inputs............................................................................. 101 Terminals A1, A2, and A3 Input Signal Selection............................................................................ 102 Terminal AM/FM Signal Selection ................................................................................................... 103 3.9 Connect to a PC.................................................................................................................104 4. START-UP PROGRAMMING & OPERATION..................................................... 105 4.1 Drive Start-Up Preparation ...............................................................................................106 Start-Up Checklist ........................................................................................................................... 106 4.2 Powering Up the Drive ......................................................................................................108 Setting the Real Time Clock............................................................................................................ 108 4.3 Using the HOA Keypad .....................................................................................................111 Keys and Displays........................................................................................................................... 111 LCD Display .................................................................................................................................... 112 ALARM (ALM) LED Displays........................................................................................................... 113 AUTO LED and HAND LED Indications .......................................................................................... 113 Menu Structure for HOA Keypad..................................................................................................... 115 Changing Parameter Settings or Values ......................................................................................... 116 4.4 Pump Application Presets ................................................................................................118 Parameters Set Depending on A1-03 Setting ................................................................................. 118 Parameters Displayed Depending on A1-06 Setting....................................................................... 119 4.5 iQpump Presets and Functions .......................................................................................120 14 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Table of Contents iQpump Presets............................................................................................................................... 120 iQpump Functions ........................................................................................................................... 131 4.6 Basic iQpump Setup and Application Preset Parameters.............................................149 4.7 Test Run with No Load......................................................................................................171 No-Load Operation Test Run .......................................................................................................... 171 4.8 Test Run with Load Connected........................................................................................172 Test Run with the Load Connected ................................................................................................. 172 5. TROUBLESHOOTING.......................................................................................... 173 5.1 Drive Alarms, Faults, Errors, and Messages ..................................................................174 Types of Alarms, Faults, and Errors................................................................................................ 174 5.2 Fault Detection ..................................................................................................................175 Fault Displays, Causes, and Possible Solutions ............................................................................. 175 5.3 Alarm Detection .................................................................................................................193 Alarm Codes, Causes, and Possible Solutions ............................................................................... 193 5.4 Operator Programming Errors .........................................................................................203 Operator Programming Error Codes, Causes, and Possible Solutions........................................... 203 5.5 Auto-Tuning Fault Detection ............................................................................................207 Auto-Tuning Codes, Causes, and Possible Solutions..................................................................... 207 5.6 Copy Function Related Displays .....................................................................................211 Tasks, Errors, and Troubleshooting ................................................................................................ 211 5.7 HOA Keypad Display Messages ......................................................................................213 Fault Reset Methods ....................................................................................................................... 213 5.8 Auto-Tuning .......................................................................................................................215 Types of Auto-Tuning ...................................................................................................................... 215 Auto-Tuning Interruption and Fault Codes ...................................................................................... 216 Auto-Tuning Operation Example ..................................................................................................... 216 6. PERIODIC INSPECTION & MAINTENANCE ...................................................... 219 6.1 Inspection ..........................................................................................................................220 Recommended Periodic Inspection................................................................................................. 220 6.2 Periodic Maintenance .......................................................................................................222 Replacement Parts.......................................................................................................................... 222 6.3 Drive Replacement ............................................................................................................224 Replacing the Drive ......................................................................................................................... 224 7. PERIPHERAL DEVICES & OPTIONS ................................................................. 227 7.1 Option Card Installation....................................................................................................228 Prior to Installing the Option ............................................................................................................ 228 Communication Option Installation Example................................................................................... 229 A. SPECIFICATIONS ................................................................................................ 233 A.1 Power Ratings ...................................................................................................................234 Three-Phase 200 V Class Drive Models 2A0004 to 2A0030 .......................................................... 234 Three-Phase 200 V Class Drive Models 2A0040 to 2A0211 .......................................................... 235 Three-Phase 200 V Class Drive Models 2A0250 to 2A0415 .......................................................... 236 Three-Phase 400 V Class Drive Models 4A0002 to 4A0031 .......................................................... 237 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 15 Table of Contents Three-Phase 400 V Class Drive Models 4A0038 to 4A0165 .......................................................... 238 Three-Phase 400 V Class Drive Models 4A0208 to 4A0675 .......................................................... 239 Three-Phase 600 V Class Drive Models 5A0003 to 5A0032 .......................................................... 240 Three-Phase 600 V Class Drive Models 5A0041 to 5A0099 .......................................................... 241 Three-Phase 600 V Class Drive Models 5A0125 to 5A0242 .......................................................... 242 A.2 Drive Specifications ..........................................................................................................243 A.3 Drive Watt Loss Data ........................................................................................................245 A.4 Drive Derating Data ...........................................................................................................247 Single-Phase Derating .................................................................................................................... 247 Temperature Derating ..................................................................................................................... 252 Altitude Derating.............................................................................................................................. 253 B. PARAMETER LIST............................................................................................... 255 B.1 A: Initialization Parameters ..............................................................................................256 A1: Initialization ............................................................................................................................... 256 A2: User Parameters....................................................................................................................... 257 B.2 b: Application.....................................................................................................................258 b1: Operation Mode Selection......................................................................................................... 258 b2: DC Injection Braking and Short Circuit Braking......................................................................... 258 b3: Speed Search............................................................................................................................ 259 b4: Timer Function .......................................................................................................................... 260 b5: PID Control................................................................................................................................ 260 b6: Dwell Function........................................................................................................................... 262 b8: Energy Saving ........................................................................................................................... 262 B.3 C: Tuning............................................................................................................................263 C1: Acceleration and Deceleration Times ....................................................................................... 263 C2: S-Curve Characteristics............................................................................................................ 263 C3: Slip Compensation.................................................................................................................... 264 C4: Torque Compensation .............................................................................................................. 264 C6: Carrier Frequency..................................................................................................................... 265 B.4 d: References.....................................................................................................................266 d1: Frequency Reference................................................................................................................ 266 d2: Frequency Upper/Lower Limits ................................................................................................. 267 d3: Jump Frequency........................................................................................................................ 267 d4: Frequency Reference Hold and Up/Down 2 Function............................................................... 268 B.5 E: Motor Parameters .........................................................................................................269 E1: V/f Pattern ................................................................................................................................. 269 E2: Motor 1 Parameters .................................................................................................................. 270 B.6 F: Options...........................................................................................................................272 F4: Analog Monitor Card (AO-A3) ................................................................................................... 272 F5: Digital Output Card (DO-A3) ..................................................................................................... 272 F6, F7: Communication Option Card............................................................................................... 273 B.7 H Parameters: Multi-Function Terminals ........................................................................276 H1: Multi-Function Digital Inputs ..................................................................................................... 276 H2: Multi-Function Digital Outputs................................................................................................... 280 H3: Multi-Function Analog Inputs .................................................................................................... 284 H4: Analog Outputs ......................................................................................................................... 286 H5: MEMOBUS/Modbus Serial Communication ............................................................................. 287 H6: Pulse Train Input....................................................................................................................... 288 16 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Table of Contents B.8 L: Protection Function ......................................................................................................289 L1: Motor Protection ........................................................................................................................ 289 L2: Momentary Power Loss Ride-Thru............................................................................................ 289 L3: Stall Prevention ......................................................................................................................... 290 L4: Speed Detection........................................................................................................................ 292 L5: Fault Restart.............................................................................................................................. 292 L6: Torque Detection....................................................................................................................... 293 L7: Torque Limit .............................................................................................................................. 294 L8: Drive Protection......................................................................................................................... 294 B.9 n: Special Adjustment.......................................................................................................296 n1: Hunting Prevention.................................................................................................................... 296 n2: Speed Feedback Detection Control (AFR) Tuning.................................................................... 296 n3: High Slip Braking (HSB) and Overexcitation Braking................................................................ 296 n6: Online Tuning ............................................................................................................................ 297 B.10 o: Operator-Related Settings ...........................................................................................298 o1: HOA Keypad Display Selection................................................................................................. 298 o2: HOA Keypad Keypad Functions................................................................................................ 299 o3: Copy Function ........................................................................................................................... 300 o4: Maintenance Monitor Settings................................................................................................... 300 B.11 P: Pump Parameters .........................................................................................................301 P1: Pump Basic............................................................................................................................... 301 P2: Pump Protection ....................................................................................................................... 303 P3: Contactor Multiplexing .............................................................................................................. 304 P4: Pump Advanced........................................................................................................................ 307 P5: Pump HAND Mode ................................................................................................................... 308 P6: Flow Meter Setup...................................................................................................................... 309 P7: Anti-Jam.................................................................................................................................... 311 P9: Network Options ....................................................................................................................... 311 B.12 Q: PID Controller Parameters...........................................................................................316 Q1: Preset Setpoint ......................................................................................................................... 316 Q2: Geothermal Mode Setup .......................................................................................................... 316 Q3: Output Current Limit ................................................................................................................. 317 Q4: Water Level Control.................................................................................................................. 317 Q5: Suction Pressure Control.......................................................................................................... 318 B.13 S: Special Application.......................................................................................................320 S1: Dynamic Noise Control Function .............................................................................................. 320 S2: Programmable Run Timers....................................................................................................... 320 S3: Secondary PI (PI2) Control ....................................................................................................... 322 S6: Protection.................................................................................................................................. 324 B.14 T: Motor Tuning .................................................................................................................325 T1: Induction Motor Auto-Tuning..................................................................................................... 325 B.15 U: Monitors.........................................................................................................................326 U1: Operation Status Monitors ........................................................................................................ 326 U2: Fault Trace................................................................................................................................ 328 U3: Fault History.............................................................................................................................. 329 U4: Maintenance Monitors .............................................................................................................. 331 U5: PID Monitors ............................................................................................................................. 333 U6: Operation Status Monitors ........................................................................................................ 334 U7: CASE Monitors ......................................................................................................................... 334 U9: Operation Status Monitors ........................................................................................................ 334 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 17 Table of Contents C. STANDARDS COMPLIANCE .............................................................................. 335 C.1 European Standards .........................................................................................................336 CE Low Voltage Directive Compliance............................................................................................ 336 EMC Guidelines Compliance .......................................................................................................... 338 C.2 UL and CSA Standards .....................................................................................................343 UL Standards Compliance .............................................................................................................. 343 CSA Standards Compliance............................................................................................................ 349 Drive Motor Overload Protection ..................................................................................................... 349 Precautionary Notes on External Heatsink (IP00/Open Type Enclosure) ....................................... 351 18 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide i Preface & General Safety This section provides safety messages pertinent to this product that, if not heeded, may result in fatality, personal injury, or equipment damage. Yaskawa is not responsible for the consequences of ignoring these instructions. i.1 i.2 PREFACE...............................................................................................................20 GENERAL SAFETY...............................................................................................22 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 19 i.1 Preface i.1 Preface Yaskawa manufactures products used as components in a wide variety of industrial systems and equipment. The selection and application of Yaskawa products remain the responsibility of the equipment manufacturer or end user. Yaskawa accepts no responsibility for the way its products are incorporated into the final system design. Under no circumstances should any Yaskawa product be incorporated into any product or design as the exclusive or sole safety control. Without exception, all controls should be designed to detect faults dynamically and fail safely under all circumstances. All systems or equipment designed to incorporate a product manufactured by Yaskawa must be supplied to the end user with appropriate warnings and instructions as to the safe use and operation of that part. Any warnings provided by Yaskawa must be promptly provided to the end user. Yaskawa offers an express warranty only as to the quality of its products in conforming to standards and specifications published in the Yaskawa manual. NO OTHER WARRANTY, EXPRESS OR IMPLIED, IS OFFERED. Yaskawa assumes no liability for any personal injury, property damage, losses, or claims arising from misapplication of its products. This manual is designed to ensure correct and suitable application of drives. Read this manual before attempting to install, operate, maintain, or inspect a drive and keep it in a safe, convenient location for future reference. Be sure you understand all precautions and safety information before attempting application. u Applicable Documentation The following manuals are available for iQpump1000 drives: iQpump1000 AC Drive Quick Start Guide (TOEPYAIP1W01) ALM DIGITAL OPERATOR JVOP-183 F1 ESC F2 M M RESET AUTO HAND ENTER OFF Read this guide first. This guide is packaged together with the product and contains basic information required to install and wire the drive. It also gives an overview of fault diagnostics, maintenance, and parameter settings. The purpose of this guide is to prepare the drive for a trial run with an application and for basic operation. This manual is available for download on our documentation website, www.yaskawa.com. iQpump1000 AC Drive Technical Manual (SIEPYAIP1W01) This manual provides detailed information on parameter settings, drive functions, and MEMOBUS/Modbus specifications. Use this manual to expand drive functionality and to take advantage of higher performance features. This manual is available for download on our documentation website, www.yaskawa.com. iQpump1000 Simplified Setup Guide Sheet (TM.iQp1K.01) This sheet is packaged together with the drive and contains a step-by-step guide to enable the user to properly wire the drive and motor. It also describes simplex pump application configuration. u Symbols Note: TERMS Indicates a supplement or precaution that does not cause drive damage. Indicates a term or definition used in this manual. u Terms and Abbreviations TERMS • • • • • • • • • • Drive: Yaskawa iQpump1000 Intelligent Pump Controller BCD: Binary Coded Decimal H: Hexadecimal Number Format IGBT: Insulated Gate Bipolar Transistor kbps: Kilobits per Second MAC: Media Access Control Mbps: Megabits per Second r/min: Revolutions per Minute V/f: V/f Control OLV: Open Loop Vector Control u Trademarks • • • • CANopen is a trademark of CAN in Automation (CiA). CC-Link is a trademark of CC-Link Partner Association (CLPA). DeviceNet is a trademark of Open DeviceNet Vendor Association, Inc. (ODVA). PROFIBUS-DP is a trademark of PROFIBUS International (PI). 20 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide i.1 Preface • MECHATROLINK-I/MECHATROLINK-II are trademarks of MECHATROLINK Members Association (MMA). • Other companies and product names mentioned in this manual are trademarks of those companies. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 21 i.2 General Safety i.2 General Safety u Supplemental Safety Information • • • • • General Precautions The diagrams in this manual may be indicated without covers or safety shields to show details. Replace the covers or shields before operating the drive and run the drive according to the instructions described in this manual. Any illustrations, photographs, or examples used in this manual are provided as examples only and may not apply to all products to which this manual is applicable. The products and specifications described in this manual or the content and presentation of the manual may be changed without notice to improve the product and/or the manual. When ordering a new copy of the manual due to damage or loss, contact your Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover. If nameplate becomes worn or damaged, order a replacement from your Yaskawa representative or the nearest Yaskawa sales office. WARNING Read and understand this manual before installing, operating or servicing this drive. The drive must be installed according to this manual and local codes. The following conventions are used to indicate safety messages in this manual. Failure to heed these messages could result in serious or fatal injury or damage to the products or to related equipment and systems. DANGER Indicates a hazardous situation, which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation, which, if not avoided, could result in death or serious injury. WARNING! may also be indicated by a bold key word embedded in the text followed by an italicized safety message. CAUTION Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury. CAUTION! may also be indicated by a bold key word embedded in the text followed by an italicized safety message. NOTICE Indicates a property damage message. NOTICE: may also be indicated by a bold key word embedded in the text followed by an italicized safety message. 22 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide i.2 General Safety u Safety Messages DANGER Heed the safety messages in this manual. Failure to comply will result in death or serious injury. The operating company is responsible for any injuries or equipment damage resulting from failure to heed the warnings in this manual. Electrical Shock Hazard Do not connect or disconnect wiring while the power is on. Failure to comply will result in death or serious injury. Before servicing, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off. After shutting off the power, wait for at least the amount of time specified on the drive before touching any components. WARNING Sudden Movement Hazard System may start unexpectedly upon application of power, resulting in death or serious injury. Clear all personnel from the drive, motor and machine area before applying power. Secure covers, couplings, shaft keys and machine loads before applying power to the drive. Electrical Shock Hazard Do not attempt to modify or alter the drive in any way not explained in this manual. Failure to comply could result in death or serious injury. Yaskawa is not responsible for any modification of the product made by the user. This product must not be modified. Do not allow unqualified personnel to use equipment. Failure to comply could result in death or serious injury. Maintenance, inspection, and replacement of parts must be performed only by authorized personnel familiar with installation, adjustment and maintenance of AC drives. Do not remove covers or touch circuit boards while the power is on. Failure to comply could result in death or serious injury. Make sure the protective earthing conductor complies with technical standards and local safety regulations. Because the leakage current exceeds 3.5 mA in models 4A0414 and larger, IEC 61800-5-1 states that either the power supply must be automatically disconnected in case of discontinuity of the protective earthing conductor or a protective earthing conductor with a cross-section of at least 10 mm2 (Cu) or 16 mm2 (Al) must be used. Failure to comply may result in death or serious injury. Always use appropriate equipment for Ground Fault Circuit Interrupters (GFCIs). The drive can cause a residual current with a DC component in the protective earthing conductor. Where a residual current operated protective or monitoring device is used for protection in case of direct or indirect contact, always use a type B GFCI according to IEC 60755. Fire Hazard Do not use an improper voltage source. Failure to comply could result in death or serious injury by fire. Verify that the rated voltage of the drive matches the voltage of the incoming power supply before applying power. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 23 i.2 General Safety WARNING Install adequate branch circuit protection according to applicable local codes and this Installation Manual. Failure to comply could result in fire and damage to the drive or injury to personnel. The device is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical amperes, 240 Vac maximum (200 V class) and 480 Vac maximum (400 V class), and 600 Vac maximum (600 V class) when protected by branch circuit protection devices specified in this supplement. Crush Hazard Do not use this drive in lifting applications without installing external safety circuitry to prevent accidental dropping of the load. The drive does not possess built-in load drop protection for lifting applications. Failure to comply could result in death or serious injury from falling loads. Install electrical and/or mechanical safety circuit mechanisms independent of drive circuitry. CAUTION Crush Hazard Do not carry the drive by the front cover. Failure to comply may result in minor or moderate injury from the main body of the drive falling. NOTICE Observe proper electrostatic discharge procedures (ESD) when handling the drive and circuit boards. Failure to comply may result in ESD damage to the drive circuitry. Do not perform a withstand voltage test on any part of the drive. Failure to comply could result in damage to the sensitive devices within the drive. Do not operate damaged equipment. Failure to comply could result in further damage to the equipment. Do not connect or operate any equipment with visible damage or missing parts. If a fuse is blown or a Ground Fault Circuit Interrupter (GFCI) is tripped, check the wiring and the selection of the peripheral devices. Contact your supplier if the cause cannot be identified after checking the above. Do not restart the drive immediately operate the peripheral devices if a fuse is blown or a GFCI is tripped. Check the wiring and the selection of peripheral devices to identify the cause. Contact your supplier before restarting the drive or the peripheral devices if the cause cannot be identified. Install adequate branch circuit short circuit protection per applicable codes. Failure to comply could result in damage to the drive. The drive is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical Amperes, 240 Vac maximum (200 V Class), 480 Vac maximum (400 V Class), and 600 Vac maximum (600 V Class) when protected by Bussmann Type FWH or FWP fuses as specified in Factory Recommended Branch Circuit Protection on page 336. Do not expose the drive to halogen group disinfectants. Failure to comply may cause damage to the electrical components in the drive. Do not pack the drive in wooden materials that have been fumigated or sterilized. Do not sterilize the entire package after the product is packed. 24 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide i.2 General Safety u General Application Precautions n Selection Installing a Reactor Use an AC reactor or DC link choke in the following situations: • to suppress harmonic current. • to smooth peak current that results from capacitor switching. • when the power supply is above 600 kVA. • when the drive is running from a power supply system with thyristor converters. Note: A DC link choke is built in to drive models 2A0110 to 2A0415 ,4A0058 to 4A0675, and 5A0041 to 5A0242. 4000 Power Supply Capacity (kVA) Power supply harmonics reactor required 600 0 Reactor unnecessary 60 400 Drive Capacity (kVA) Figure i.1 Installing a Reactor Single-Phase Input Selection The drive is capable of single phase input. Refer to Main Circuit Connection Diagram on page 77 for connection diagrams and Refer to Single-Phase Derating on page 247 for application instructions and drive current ratings. Drive Capacity For specialized motors, make sure that the motor rated current is less than the rated output current for the drive. When running more than one motor in parallel from a single drive, the capacity of the drive should be larger than [total motor rated current × 1.1]. n Installation Enclosure Panels Keep the drive in a clean environment by installing the drive in an enclosure panel or selecting an installation area free of airborne dust, lint, and oil mist. Be sure to leave the required space between drives to provide for cooling, and take proper measures so the ambient temperature remains within allowable limits and keep flammable materials away from the drive. Yaskawa offers protective designs for drives that must be used in areas subjected to oil mist and excessive vibration. Contact Yaskawa or your Yaskawa agent for details. Installation Direction NOTICE: Install the drive upright as specified in the manual. Refer to Mechanical Installation on page 34 for more information on installation. Failure to comply may damage the drive due to improper cooling. n Settings Upper Limits NOTICE: The drive is capable of running the motor up to 400 Hz. Be sure to set the upper limit for the frequency of the drive to prevent the possible danger of accidentally operating equipment at higher than rated speed. The default setting for the maximum output frequency is 60 Hz. Lower Limits NOTICE: Many pumps have a minimum safe operating speed. Be sure to properly set the minimum pump speed in to protect the pump from damage. DC Injection Braking NOTICE: Excessive current during DC Injection Braking and excessive duration of DC Injection Braking can cause motor overheat. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 25 i.2 General Safety Acceleration/Deceleration Times Acceleration and deceleration times are affected by the amount of torque generated by the motor, the load torque, and the inertia moment. Set a longer accel/decel time when Stall Prevention is enabled. The accel/decel times are lengthened for as long as the Stall Prevention function is in operation. n General Handling Wiring Check NOTICE: Do not connect power supply lines to output terminals U/T1, V/T2, or W/T3. Failure to comply will destroy the drive. Be sure to perform a final check of all sequence wiring and other connections before turning on the power and also check for short circuits on the control terminals, which may damage the drive. Selecting a Circuit Breaker or Circuit Interrupter Yaskawa recommends installing a Ground Fault Circuit Interrupter (GFCI) to the power supply side. The GFCI should be designed for use with AC drives (e.g., Type B according to IEC 60755). Select a Molded Case Circuit Breaker (MCCB) or GFCI with a rated current 1.5 to 2 times higher than the drive rated input current to avoid nuisance trips caused by harmonics in the drive input current. Magnetic Contactor Installation NOTICE: To get the full performance life out of the electrolytic capacitors and circuit relays, refrain from switching the drive power supply off and on more than once every 30 minutes. Frequent use can damage the drive. Use the drive to stop and start the motor. Inspection and Maintenance WARNING! Electrical Shock Hazard. Capacitors in the drive do not immediately discharge after shutting off the power. Wait for at least the amount of time specified on the drive before touching any components after shutting off the power. Failure to comply may cause injury to personnel from electrical shock. WARNING! Burn Hazard. Because the heatsink can get very hot during operation, take proper precautions to prevent burns. When replacing the cooling fan, shut off the power and wait at least 15 minutes to be sure that the heatsink has cooled down. Failure to comply may cause burn injury to personnel. Wiring Yaskawa recommends using ring terminals on all drive models. Drive models 2A0069 to 2A0415, 4A0058 to 4A0675, and 5A0041 to 5A0242 require the use of use ring terminals for UL/cUL compliance. Use only the tools recommended by the terminal manufacturer for crimping. Transporting the Drive NOTICE: Never steam clean the drive. During transport, keep the drive from coming into contact with salts, fluorine, bromine, phthalate ester, and other such harmful chemicals. u Motor Application Precautions n Standard Induction Motors Insulation Tolerance NOTICE: Consider motor voltage tolerance levels and motor insulation in applications with an input voltage of over 440 V or particularly long wiring distances. High-Speed Operation NOTICE: Problems may occur with the motor bearings and dynamic balance of the machine when operating a motor beyond its rated speed. Contact the motor or machine manufacturer. Torque Characteristics Torque characteristics differ compared to operating the motor directly from line power. The user should have a full understanding of the load torque characteristics for the application. Vibration and Shock The drive allows selection of high carrier PWM control and low carrier PWM. Selecting high carrier PWM can help reduce motor oscillation (drive current derating may be required). Take particular caution when adding a variable speed drive to an application running a motor from line power at a constant speed. If resonance occurs, use shock absorbing mounts to the motor base and enable the Jump frequency selection to prevent continuous operation in the resonant frequency range. Audible Noise The audible noise of the motor varies based on the carrier frequency setting. However, drive current derating may be required. When using a high carrier frequency, audible noise from the motor is comparable to the motor noise generated when running from line power. 26 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide i.2 General Safety n Specialized Motors Submersible Motor The rated current of a submersible motor is greater than that of a standard motor, so select the drive capacity accordingly. Use a motor cable large enough to avoid decreasing the maximum torque level from voltage drop caused by a long motor cable. Explosion-Proof Motor The motor and the drive must be tested together to be certified as explosion-proof. The drive is not designed for explosionproof areas. Geared Motor Make sure that the gear and the lubricant are rated for the desired speed range to avoid gear damage when operating at low speeds or very high speeds. Consult with the manufacturer for applications that require operation outside the rated speed range of the motor or gear box. Single-Phase Motor Variable speed drives are not designed to operate with single phase motors. Using capacitors to start the motor causes excessive current to flow and can damage drive components. A split-phase start or a repulsion start can burn out the starter coils because the internal centrifugal switch is not activated. The drive is for use with three-phase motors only. n Notes on Power Transmission Machinery Installing an AC drive in machinery that was previously connected directly to the power supply will allow the machine to operate at variable speeds. Continuous operation outside of the rated speeds can wear on lubrication material in gear boxes and other power transmission parts. Make sure that lubrication is sufficient within the entire speed range to avoid machine damage. Note that operation above the rated speed can increase the noise generated by the machine. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 27 i.2 General Safety u Drive Label Warning Example Always heed the warning information listed in Figure i.2 in the position shown in Figure i.3. WARNING ● ● ● ● Risk of electric shock. Read manual before installing. Wait 5 minutes for capacitor discharge after disconnecting power supply. To conform to requirements, make sure to ground the supply neutral for 400V class. After opening the manual switch between the drive and motor, please wait 5 minutes before inspecting, performing maintenance or wiring the drive. Hot surfaces ● Top and Side surfaces may become hot. Do not touch. Figure i.2 Warning Information Example ALM DIGITAL OPERATOR JVOP-183 F1 ESC F2 M M HAND RESET ENTER AUTO OFF 600V 3Phase 5.5kW/3.7kW Warning Label Figure i.3 Warning Information Position u Warranty Information n Restrictions The drive is not designed or manufactured for use in devices or systems that may directly affect or threaten human lives or health. Customers who intend to use the product described in this manual for devices or systems relating to transportation, health care, space aviation, atomic power, electric power, or in underwater applications must first contact their Yaskawa representatives or the nearest Yaskawa sales office. WARNING! Injury to Personnel. This product has been manufactured under strict quality-control guidelines. However, if this product is to be installed in any location where failure of this product could involve or result in a life-and-death situation or loss of human life or in a facility where failure may cause a serious accident or physical injury, safety devices must be installed to minimize the likelihood of any accident. 28 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 1 Receiving This chapter explains how to inspect the drive upon receipt, and gives an overview of the different enclosure types and components. 1.1 MODEL NUMBER AND NAMEPLATE CHECK....................................................30 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 29 1.1 Model Number and Nameplate Check 1.1 Model Number and Nameplate Check Please perform the following tasks after receiving the drive: • Inspect the drive for damage. If the drive appears damaged upon receipt, contact the shipper immediately. • Verify receipt of the correct model by checking the information on the nameplate. • If you have received the wrong model or the drive does not function properly, contact your supplier. u Nameplate A H G F IND.CONT.EQ. 7J48 B B E D : C A – Normal Duty Amps B – Software version C – Enclosure type D – Serial number E – Lot number F – Output specifications G – Input specifications H – AC drive model Figure 1.1 Nameplate Information Example 30 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 1.1 Model Number and Nameplate Check CIMR - P W 2 Drive P1000 Series No. W Region Code Water 0021 A F No. Customized Specifications No. Enclosure Type <1> A Standard model A IP00/Open Type Voltage Class 2 3-phase, 200-240 Vac F IP20/NEMA Type 1 4 3-phase, 380-480 Vac U 5 3-phase, 500-600 Vac Flange Type <2> No. No. A A A Design Revision Order Environmental Specification <3> Standard Refer to the tables below <1> Refer to Mechanical Installation on page 34 for differences regarding enclosure protection types and component descriptions. <2> Provides method of mounting drive with backside (heatsink) external to enclosure, with NEMA 12 integrity. <3> Please contact Yaskawa for details regarding Environmental Specifications. n Three-Phase 200 V Class Table 1.1 Model Number and Specifications (200 V Class) Max. Motor Capacity kW (HP) 0.75 (0.75) 1.1 (1) 1.5 (2) 2.2 (3) 3.0 (3) 3.7 (5) 5.5 (7.5) 7.5 (10) 11 (15) 15 (20) 18.5 (25) 22 (30) 30 (40) 37 (50) 45 (60) 55 (75) 75 (100) 90 (125) 110 (150) 110 (175) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Rated Output Current A 3.5 6.0 8.0 9.6 12 17.5 21 30 40 56 69 81 110 138 169 211 250 312 360 415 Receiving Drive Model 2A0004 2A0006 2A0008 2A0010 2A0012 2A0018 2A0021 2A0030 2A0040 2A0056 2A0069 2A0081 2A0110 2A0138 2A0169 2A0211 2A0250 2A0312 2A0360 2A0415 1 31 1.1 Model Number and Nameplate Check n Three-Phase 400 V Class Table 1.2 Model Number and Specifications (400 V Class) Drive Model 4A0002 4A0004 4A0005 4A0007 4A0009 4A0011 4A0018 4A0023 4A0031 4A0038 4A0044 4A0058 Max. Motor Capacity kW (HP) 0.75 (0.75) 1.5 (2) 2.2 (3) 3.0 (3) 3.7 (5) 5.5 (7.5) 7.5 (10) 11 (15) 15 (20) 18.5 (25) 22 (30) 30 (40) Rated Output Current A 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23 31 38 44 58 4A0072 4A0088 4A0103 4A0139 4A0165 4A0208 4A0250 4A0296 4A0362 4A0414 4A0515 4A0675 37 (50) 45 (60) 55 (75) 75 (100) 90 (125) 110 (150) 132 (200) 160 (250) 185 (300) 220 (350) 250 (400-450) 355 (500-550) 72 88 103 139 165 208 250 296 362 414 515 675 n Three-Phase 600 V Class Table 1.3 Model Number and Specifications (600 V Class) Drive Model 5A0003 5A0004 5A0006 5A0009 5A0011 5A0017 5A0022 5A0027 5A0032 5A0041 5A0052 5A0062 5A0077 5A0099 5A0125 5A0145 5A0192 5A0242 Note: 32 Max. Motor Capacity kW (HP) 1.5 (2) 2.2 (3) 3.7 (5) 5.5 (7.5) 7.5 (10) 11 (15) 15 (20) 18.5 (25) 22 (30) 30 (40) 37 (50) 45 (60) 55 (75) 75 (100) 90 (125) 110 (150) 160 (200) 185 (250) Rated Output Current A 2.7 3.9 6.1 9 11 17 22 27 32 41 52 62 77 99 125 145 192 242 Refer to Single-Phase Derating on page 247 for Single-Phase ratings. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2 Mechanical Installation This chapter explains how to properly mount and install the drive. 2.1 MECHANICAL INSTALLATION.............................................................................34 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 33 2.1 Mechanical Installation 2.1 Mechanical Installation This section outlines specifications, procedures, and the environment for proper mechanical installation of the drive. u Installation Environment Install the drive in an environment matching the specifications in Table 2.1 to help prolong the optimum performance life of the drive. Table 2.1 Installation Environment Environment Installation Area Ambient Temperature Humidity Storage Temperature Surrounding Area Altitude Vibration Orientation Conditions Indoors -10 °C to +40 °C (IP20/NEMA Type 1 enclosure) -10 °C to +50 °C (IP00/Open Type enclosure) Drive reliability improves in environments without wide temperature fluctuations. When using the drive in an enclosure panel, install a cooling fan or air conditioner in the area to ensure that the air temperature inside the enclosure does not exceed the specified levels. Do not allow ice to develop on the drive. 95% RH or less and free of condensation -20 to +60 °C Install the drive in an area free from: • oil mist and dust • metal shavings, oil, water, or other foreign materials • radioactive materials • combustible materials (e.g., wood) • harmful gases and liquids • excessive vibration • chlorides • direct sunlight. 1000 m or lower, up to 3000 m with derating 10 to 20 Hz at 9.8 m/s2 20 to 55 Hz at 5.9 m/s2 (Models 2A0004 to 2A0211, 4A0002 to 4A0165, and 5A0003 to 5A0099) or 2.0 m/s2 (Models 2A0250 to 2A0415, 4A0208 to 4A0675, and 5A0125 to 5A0242) Install the drive vertically to maintain maximum cooling effects. NOTICE: Avoid placing drive peripheral devices, transformers, or other electronics near the drive as the noise created can lead to erroneous operation. If such devices must be used in close proximity to the drive, take proper steps to shield the drive from noise. NOTICE: Prevent foreign matter such as metal shavings and wire clippings from falling into the drive during installation. Failure to comply could result in damage to the drive. Place a temporary cover over the top of the drive during installation. Remove the temporary cover before drive start-up, as the cover will reduce ventilation and cause the drive to overheat. u Installation Orientation and Spacing Install the drive upright as illustrated in Figure 2.1 to maintain proper cooling. Figure 2.1 Correct Installation Orientation 34 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation n Single Drive Installation Figure 2.2 shows the installation distance required to maintain sufficient space for airflow and wiring. Install the heatsink against a closed surface to avoid diverting cooling air around the heatsink. Side Clearance Top/Bottom Clearance A C B D D C B A A – 50 mm minimum B – 30 mm minimum C – 120 mm minimum D – Airflow direction Figure 2.2 Correct Installation Spacing Note: IP20/NEMA Type 1 enclosure and IP00/Open Type enclosure models require the same amount of space above and below the drive for installation. n Multiple Drive Installation (Side-by-Side Installation) Mechanical Installation Models 2A0004 to 2A0081, 4A0002 to 4A0044, and 5A0003 to 5A0032 can take advantage of Side-by-Side installation. When installing multiple drives into the same enclosure panel, mount the drives according to Figure 2.2 and set L8-35, Installation Method Selection, to 1 (Side-by-Side Mounting). When mounting drives with the minimum clearance of 2 mm according to Figure 2.3, set parameter L8-35 to 1 while considering derating. Refer to Parameter List on page 255 for details. Line up the tops of the drives. Side Clearance Top/Bottom Clearance C A A D 2 B A A – 50 mm minimum B – 30 mm minimum B D A C – 2 mm minimum D – 120 mm minimum Figure 2.3 Space Between Drives (Side-by-Side Mounting) Note: Align the tops of the drives when installing drives of different heights in the same enclosure panel. Leave space between the tops and bottoms of stacked drives for easier cooling fan replacement. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 35 2.1 Mechanical Installation Remove the top protective covers of all drives as shown in Figure 2.4 when mounting IP20/NEMA Type 1 enclosure drives side-by-side. Refer to Top Protective Cover on page 84 to remove and reattach the top protective cover. Figure 2.4 IP20/NEMA 1 Side-by-Side Mounting in Enclosure u Transporting the Drive CAUTION! Do not lift the drive by the front cover. Failure to comply may result in minor or moderate injury if the main body of the drive falls. Figure 2.5 Incorrect Way to Transport the Drive u HOA Keypad Remote Usage n Remote Operation The HOA keypad mounted on the drive can be removed and connected to the drive using an extension cable up to 3 m (9.8 ft.) long to facilitate operation when the drive is installed in a location where it can not be easily accessed. The HOA keypad can also be permanently mounted remote locations such as panel doors using an extension cable and an installation support set (depending on the installation type). Note: 36 Refer to Peripheral Devices & Options on page 227 for information on extension cables and installation support sets. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation HOA Keypad Drive Comm Port Communication Cable Connector Figure 2.6 Communication Cable Connection n HOA Keypad Remote Installation HOA Keypad Dimensions Mechanical Installation 15 (0.59) 78 (3.07) Installation Holes (2-M3 Screws, Depth 5) 44 (1.73) Unit: mm (in) Figure 2.7 HOA Keypad Dimensions Installation Types and Required Materials The HOA keypad mounts to an enclosure two different ways: • External/face-mount installs the HOA keypad outside the enclosure panel • Internal/flush-mount installs the HOA keypad inside the enclosure panel 2 Table 2.2 HOA Keypad Installation Methods and Required Tools Installation Method Description Installation Support Sets Model Required Tools External/ Face-Mount Simplified installation with the HOA keypad is mounted on the outside of the panel with two screws. – – Phillips screwdriver (#1) Installation Support Set A (for mounting with screws through holes in the panel) Installation Support Set B (for use with threaded studs that are fixed to the panel) EZZ020642A Internal/ Flush-Mount Encloses the HOA keypad in the panel. The front of the HOA keypad is flush with the outside of the panel. Phillips screwdriver (#1, #2) EZZ020642B Phillips screwdriver (#1) Wrench (7 mm) NOTICE: Prevent foreign matter such as metal shavings or wire clippings from falling into the drive during installation and project construction. Failure to comply could result in damage to the drive. Place a temporary cover over the top of the drive during installation. Remove the temporary cover before drive start-up, as the cover will reduce ventilation and cause the drive to overheat. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 37 2.1 Mechanical Installation External/Face-Mount 1. Cut an opening in the enclosure panel for the HOA keypad as shown in Figure 2.8. 2. Position the HOA keypad so the display faces outwards, and mount it to the enclosure panel as shown in Figure 2.9. 22 (0.87) 2 (0.08) 26 (1.02) 78 (3.1) 22 (0.87) 22 (0.87) 14 (0.56) Unit: mm (in) Figure 2.8 Panel Cut-Out Dimensions (External/Face-Mount Installation) HOA Keypad M3 x 6 Phillips recessed pan head machine screw x 2 Enclosure panel Figure 2.9 External/Face-Mount Installation Internal/Flush-Mount An internal/flush-mount requires an installation support set that must be purchased separately. Contact Yaskawa to order an installation support set and mounting hardware. Figure 2.10 illustrates how to attach the Installation Support Set A. 1. 2. 3. Cut an opening in the enclosure panel for the HOA keypad as shown in Figure 2.11. Mount the HOA keypad to the installation support. Mount the installation support set and HOA keypad to the enclosure panel. Enclosure panel HOA Keypad Installation Support Set A M4 × 10 Phillips truss head screw × 4 (for panel widths between 1 (0.04) and 1.6 (0.06)) M3 × 6 Phillips recessed pan head machine screw × 2 Unit: mm (in) Figure 2.10 Internal/Flush Mount Installation Note: 38 Use a gasket between the enclosure panel and the HOA keypad in environments with a significant amount of dust or other airborne debris. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 120 (4.72) (0.02) 89 (3.5) +0.5 0 2.1 Mechanical Installation 45 (1.77) (0.02) 59 (2.32) +0.5 0 Unit : mm (in) Figure 2.11 Panel Cut-Out Dimensions (Internal/Flush-Mount Installation) u Exterior and Mounting Dimensions Table 2.3 Drive Models and Types IP20/NEMA Type 1 Enclosure IP00/Open Type Enclosure Three-Phase 200 V Class 2A0004F 2A0006F 2A0008F 2A0010F 2A0012F 2A0018F 2A0021F 2A0030F 2A0040F 2A0056F 2A0069F 2A0081F 2A0110F 2A0138F 2A0169F 2A0211F 2A0250A <1> 2A0312A <1> 2A0360A <1> 2A0415A <2> Drive Model Three-Phase 400 V Class 4A0002F 4A0004F 4A0005F 4A0007F 4A0009F 4A0011F 4A0018F 4A0023F 4A0031F 4A0038F 4A0044F 4A0058F 4A0072F 4A0088F 4A0103F 4A0139F 4A0165F 4A0208A <1> 4A0250A <1> 4A0296A <1> 4A0362A <1> 4A0414A <2> 4A0515A <2> 4A0675A <2> 4A0930A <2> 4A1200A <2> YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Three-Phase 600 V Class Page 5A0003F 5A0004F 5A0006F 5A0009F 5A0011F 5A0017F 5A0022F 5A0027F 5A0032F 5A0041F 5A0052F 5A0062F 5A0077F 5A0099F 41 5A0125A <1> 5A0145A <1> 5A0192A <1> 5A0242A <1> 45 Mechanical Installation Protective Design 2 39 2.1 Mechanical Installation Drive Model Protective Design Flange Type Enclosure (NEMA 12 Backside) Three-Phase 200 V Class 2A0004U 2A0006U 2A0008U 2A0010U 2A0012U 2A0018U 2A0021U 2A0030U 2A0040U 2A0056U 2A0069U 2A0081U 2A0110U 2A0138U 2A0169U 2A0211U 2A0250U 2A0312U 2A0360U 2A0415U Three-Phase 400 V Class 4A0002U 4A0004U 4A0005U 4A0007U 4A0009U 4A0011U 4A0018U 4A0023U 4A0031U 4A0038U 4A0044U 4A0058U 4A0072U 4A0088U 4A0103U 4A0139U 4A0165U 4A0208U 4A0250U 4A0296U 4A0362U 4A0414U 4A0515U 4A0675U Three-Phase 600 V Class 5A0003U 5A0004U 5A0006U 5A0009U 5A0011U 5A0017U 5A0022U 5A0027U 5A0032U 5A0041U 5A0052U 5A0062U 5A0077U 5A0099U 5A0125U 5A0145U 5A0192U 5A0242U Page 48 <1> Customers may convert these models to IP20/NEMA Type 1 enclosures using an IP20/NEMA Type 1 Kit. Refer to IP20/NEMA Type 1 Kit Selection on page 47 to select the appropriate kit. <2> Contact a Yaskawa representative for IP20/NEMA Type 1 Kit availability for these models. 40 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation n IP20/NEMA Type 1 Enclosure Drives Removing the top protective cover or bottom conduit bracket from an IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection while maintaining IP20 conformity. H1 H H0 t2 H2 H3 H3 H2 H1 H0 4-d W1 H4 4-d W1 H Note: t1 t1 D1 D W Max.W2 D Max.W2 W Figure 1 D1 Figure 2 Table 2.4 Dimensions for IP20/NEMA Type 1 Enclosure: 200 V Class Dimensions (in) Figure 2A0004F W H D W1 W2 H0 H1 H2 H3 H4 D1 t1 t2 d Wt. (lb) 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.3 2A0006F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.3 2A0008F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.5 2A0010F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.5 2A0012F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.5 5.51 11.81 6.46 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 8.2 2A0018F 1 2A0021F <1> 5.51 11.81 6.46 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 8.2 2A0030F 5.51 11.81 6.57 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 9.3 2A0040F 5.51 11.81 6.57 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 9.3 2A0056F 7.09 13.39 7.36 6.30 – 11.81 11.18 0.31 1.57 0.06 2.95 0.20 – M5 13.0 2A0069F 8.66 15.75 7.76 7.56 – 13.78 13.19 0.31 1.97 0.06 3.07 0.20 – M6 20.1 2A0081F 8.66 15.75 7.76 7.56 – 13.78 13.19 0.31 1.97 0.06 3.07 0.20 – M6 22.0 2A0110F 10.00 21.02 10.16 7.68 0.31 15.75 15.16 0.30 5.28 – 3.94 0.09 0.09 M6 50.7 10.98 24.17 10.16 8.66 0.31 17.72 17.13 0.30 6.46 – 3.94 0.09 0.09 M6 61.7 2A0138F 2 2A0169F <1> 2A0211F 12.95 28.74 11.14 10.24 0.31 21.65 21.06 0.30 7.09 – 4.33 0.09 0.09 M6 90.4 12.95 28.74 11.14 10.24 0.31 21.65 21.06 0.30 7.09 – 4.33 0.09 0.09 M6 92.6 Mechanical Installation Drive Model 2 Dimensions below are the dimensions of IP00/Open Type models after customer installation of the appropriate IP20/NEMA Type 1 Kit. 2A0250A 2A0312A 2A0360A 2 17.95 37.80 12.99 12.80 0.31 27.76 26.77 0.49 10.04 – 5.12 0.13 0.13 M10 183.0 17.95 37.80 12.99 12.80 0.31 27.76 26.77 0.49 10.04 – 5.12 0.13 0.13 M10 194.0 19.84 45.98 13.78 14.57 0.31 31.50 30.43 0.51 14.49 – 5.12 0.18 0.18 M12 238.1 <1> Removing the top protective cover from a IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection while retaining IP20 conformity. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 41 2.1 Mechanical Installation Table 2.5 Dimensions for IP20/NEMA Type 1 Enclosure: 400 V Class Drive Model Dimensions (in) W H D W1 W2 H0 H1 H2 H3 H4 D1 t1 t2 d 4A0002F Figure 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 Wt. (lb) 7.5 4A0004F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.5 4A0005F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.5 4A0007F 5.51 11.81 6.46 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 7.9 5.51 11.81 6.46 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 8.2 4A0009F 4A0011F 1 <1> 4A0018F 5.51 11.81 6.46 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 8.2 5.51 11.81 6.57 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 9.0 4A0023F 5.51 11.81 6.57 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 9.0 4A0031F 7.09 13.39 6.57 6.30 – 11.81 11.18 0.31 1.57 0.06 2.17 0.20 – M5 12.6 4A0038F 7.09 13.39 7.36 6.30 – 11.81 11.18 0.31 1.57 0.06 2.95 0.20 – M5 13.2 4A0044F 8.66 15.75 7.76 7.56 – 13.78 13.19 0.31 1.97 0.06 3.07 0.20 – M6 19.2 4A0058F 10.00 18.31 10.16 7.68 0.31 15.75 15.16 0.30 2.56 – 3.94 0.09 0.09 M6 50.7 4A0072F 10.98 20.28 10.16 8.66 0.31 17.72 17.13 0.30 2.56 – 3.94 0.09 0.09 M6 59.5 4A0088F 2 12.95 24.80 10.16 10.24 0.31 20.08 19.49 0.30 4.72 – 4.13 0.09 0.13 M6 86.0 4A0103F <1> 12.95 24.80 10.16 10.24 0.31 20.08 19.49 0.30 4.72 – 4.13 0.09 0.13 M6 86.0 4A0139F 12.95 28.74 11.14 10.24 0.31 21.65 21.06 0.30 7.09 – 4.33 0.09 0.09 M6 99.2 4A0165F 12.95 28.74 11.14 10.24 0.31 21.65 21.06 0.30 7.09 – 4.33 0.09 0.09 M6 101.4 Dimensions below are the dimensions of IP00/Open Type models after customer installation of the appropriate IP20/NEMA Type 1 Kit. 4A0208A 17.95 37.80 12.99 12.80 0.31 27.76 26.77 0.49 10.04 – 5.12 0.13 0.13 M10 191.8 4A0250A 19.84 45.98 13.78 14.57 0.31 31.50 30.43 0.51 14.49 – 5.12 0.18 0.18 M12 233.7 19.84 45.98 13.78 14.57 0.31 31.50 30.43 0.51 14.49 – 5.12 0.18 0.18 M12 246.9 19.84 45.98 13.78 14.57 0.31 31.50 30.43 0.51 14.49 – 5.12 0.18 0.18 M12 257.9 4A0296A 2 4A0362A <1> Removing the top protective cover from a IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection while retaining IP20 conformity. Table 2.6 Dimensions for IP20/NEMA Type 1 Enclosure: 600 V Class Drive Model Dimensions (in) W H D W1 W2 H0 H1 H2 H3 H4 D1 t1 t2 d Wt. (lb) 5A0003F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.5 5A0004F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.5 5A0006F 5.51 11.81 6.46 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 8.2 5A0009F 5.51 11.81 6.46 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 8.2 5A0011F Figure 1 5.51 11.81 6.57 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 9.0 5A0017F 7.09 13.39 7.36 6.30 – 11.81 11.18 0.31 1.57 0.06 2.95 0.20 – M5 13.2 5A0022F 7.09 13.39 7.36 6.30 – 11.81 11.18 0.31 1.57 0.06 2.95 0.20 – M5 13.2 5A0027F 8.66 15.75 7.76 7.56 – 13.78 13.19 0.31 1.97 0.06 3.07 0.20 – M6 19.2 5A0032F 8.66 15.75 7.76 7.56 – 13.78 13.19 0.31 1.97 0.06 3.07 0.20 – M6 19.2 5A0041F 10.98 20.28 10.16 8.66 0.31 17.72 17.13 0.30 2.56 – 3.94 0.09 0.09 M6 59.5 10.98 20.28 10.16 8.66 0.31 17.72 17.13 0.30 2.56 – 3.94 0.09 0.09 M6 59.5 12.95 28.74 11.14 10.24 0.31 21.65 21.06 0.30 7.09 – 4.33 0.09 0.09 M6 99.2 5A0077F 12.95 28.74 11.14 10.24 0.31 21.65 21.06 0.30 7.09 – 4.33 0.09 0.09 M6 99.2 5A0099F 12.95 28.74 11.14 10.24 0.31 21.65 21.06 0.30 7.09 – 4.33 0.09 0.09 M6 99.2 <1> 5A0052F 5A0062F 2 Dimensions below are the dimensions of IP00/Open Type models after customer installation of the appropriate IP20/NEMA Type 1 Kit. 5A0125A 17.95 37.80 12.99 12.80 0.31 27.76 26.77 0.49 10.04 – 5.12 0.13 0.13 M10 191.8 5A0145A 17.95 37.80 12.99 12.80 0.31 27.76 26.77 0.49 10.04 – 5.12 0.13 0.13 M10 191.8 19.84 45.98 13.78 14.57 0.31 31.50 30.43 0.51 14.49 – 5.12 0.18 0.18 M12 233.7 19.84 45.98 13.78 14.57 0.31 31.50 30.43 0.51 14.49 – 5.12 0.18 0.18 M12 257.9 5A0192A 5A0242A 2 <1> Removing the top protective cover or bottom conduit bracket from an IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection while maintaining IP20 conformity. 42 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation IP20/NEMA Type 1 Enclosure Conduit Bracket Dimensions W W2 Ød6 Ød6 Ød7 Ød7 W1 D D D D3 D1 D3 D2 D3 D2 Ød5 W2 W1 W1 Ød6 Ød5 W1 D1 W D1 W W W1 Ød5 D2 W W W1 Figure 1 Figure 2 Figure 3 W W W W1 W1 W2 W W1 Ød5 W2 W2 Ød5 W1 W W2 W W1 Ød6 Ød5 W1 Ød6 Ød6 D1 D2 D2 Ød7 D D D D3 D2 D3 D3 D1 D1 Ød7 Figure 6 Figure 5 W W W2 W4 W1 W Ød5 W Ød6 W3 W3 W1 W1 W2 W2 W W1 W Ød5 W3 Ød6 W1 Ød5 W4 W4 Ød6 Mechanical Installation Figure 4 D D D2 D3 D1 D2 D3 D2 D1 D3 D4 D1 Ød7 D W2 W3 W3 Ød7 Ød7 W2 2 Figure 9 Figure 8 Figure 7 Table 2.7 Conduit Bracket Dimensions for IP20/NEMA Type 1 Drive Model Dimensions (in) Figure W D W1 W2 W3 Diameter (in) W4 D1 D2 D3 D4 d5 d6 d7 200 V Class 2A0004F 1.7 1.5 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 2A0006F 1.7 1.5 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 1.7 1.5 1.5 – – – 1.6 2.8 3.1 – – – – 2A0008F 1 2A0010F 1.7 1.5 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 2A0012F 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 43 2.1 Mechanical Installation Drive Model Dimensions (in) Figure Diameter (in) W D W1 W2 W3 W4 D1 D2 D3 D4 d5 d6 d7 2A0018F 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 1.4 0.9 1.7 2A0021F 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 1.4 0.9 1.7 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 1.4 0.9 1.7 1 3 2.2 – – – 1.9 3.3 2.1 – 1.4 0.9 1.7 1 3 2.2 – – – 1.9 3.3 2.1 – 1.4 0.9 1.7 2A0030F 2A0040F 2 2A0056F 2A0069F 1.1 3.1 2.5 – – – 2 3.4 2.2 – 1.4 0.9 1.7 2A0081F 1.1 3.1 2.5 – – – 2 3.4 2.2 – 1.4 0.9 1.7 2A0110F 4 3.4 3.9 1.5 0.9 – – 3.9 1.7 1.0 – 2.4 1.1 – 2A0138F 5 3.9 3.9 3.5 1.6 – – 3.9 1.7 1.0 – 2.0 2.4 1.1 4.4 4.3 2.2 0.6 1.2 2.6 4.7 4.3 2.1 1.6 2.0 1.4 2.4 2A0169F 2A0211F 2A0250A 2A0312A 2A0360A 7 8 9 4.4 4.3 2.2 0.6 1.2 2.6 4.7 4.3 2.1 1.6 2.0 1.4 2.4 6.9 5.1 3.6 3.3 1.0 – 5.4 2.0 1.6 – 2.0 2.4 1.4 6.9 5.1 3.6 3.3 1.0 – 5.4 2.0 1.6 – 2.0 2.4 1.4 7.5 5.1 4.1 1.2 1.1 2.8 6.2 2.8 2.0 – 2.0 2.4 1.7 400 V Class 4A0002F 1.7 1.5 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 4A0004F 1.7 1.5 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 4A0005F 1.7 1.5 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 4A0007F 1 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 4A0009F 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 4A0011F 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 4A0018F 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 4A0023F 1 3 2.2 – – – 1.9 3.3 2.1 – 1.4 0.9 1.7 4A0031F 4A0038F 2 4A0044F 4A0058F 4A0072F 4A0088F 4A0103F 4A0139F 4A0165F 4A0208A 3 6 7 8 4A0250A 4A0296A 9 4A0362A 1 3 2.2 – – – 1.9 3.3 2.1 – 1.4 0.9 1.7 1.1 3.1 2.5 – – – 2 3.4 2.2 – 1.4 0.9 1.7 1.1 3.1 2.5 – – – 2 3.4 2.2 – 1.4 0.9 1.7 3.4 3.9 1.5 0.9 – – 3.9 1.7 1.0 – 2.4 1.1 2.0 3.5 3.9 1.6 0.9 – – 3.9 1.7 1.0 – 2.4 1.1 2.0 3.3 4.1 0.9 – – – 3.9 2.6 1.0 – 2.0 2.4 1.1 3.3 4.1 0.9 – – – 3.9 2.6 1.0 – 2.0 2.4 1.1 4.4 4.3 2.2 0.6 1.2 2.6 4.7 4.3 2.1 1.6 2.0 1.4 2.4 4.4 4.3 2.2 0.6 1.2 2.6 4.7 4.3 2.1 1.6 2.0 1.4 2.4 6.9 5.1 3.6 3.3 1.0 – 5.4 2.0 1.6 – 2.0 2.4 1.4 7.5 5.1 4.1 1.2 1.1 2.8 6.2 2.8 2.0 – 2.0 2.4 1.7 7.5 5.1 4.1 1.2 1.1 2.8 6.2 2.8 2.0 – 2.0 2.4 1.7 7.5 5.1 4.1 1.2 1.1 2.8 6.2 2.8 2.0 – 2.0 2.4 1.7 600 V Class 5A0003F 1.7 1.5 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 5A0004F 1.7 1.5 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 5A0006F 44 1 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 5A0009F 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – 5A0011F 1.7 2.2 1.5 – – – 1.6 2.8 3.1 – 0.9 1.4 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation Drive Model Dimensions (in) Figure 5A0017F 5A0022F 2 5A0027F 5A0032F 5A0041F 3 5A0052F 5A0062F 7 5A0077F 5A0099F 5A0125A 8 5A0145A 5A0192A 9 5A0242A Note: Diameter (in) W D W1 W2 W3 W4 D1 D2 D3 D4 d5 d6 d7 1 3 2.2 – – – 1.9 3.3 2.1 – 1.4 0.9 1.7 1 3 2.2 – – – 1.9 3.3 2.1 – 1.4 0.9 1.7 1.1 3.1 2.5 – – – 2 3.4 2.2 – 1.4 0.9 1.7 1.1 3.1 2.5 – – – 2 3.4 2.2 – 1.4 0.9 1.7 3.5 3.9 1.6 0.9 – – 3.9 1.7 1.0 – 2.4 1.1 2.0 3.5 3.9 1.6 0.9 – – 3.9 1.7 1.0 – 2.4 1.1 2.0 4.4 4.3 2.2 0.6 1.2 2.6 4.7 4.3 2.1 1.6 2.0 1.4 2.4 4.4 4.3 2.2 0.6 1.2 2.6 4.7 4.3 2.1 1.6 2.0 1.4 2.4 4.4 4.3 2.2 0.6 1.2 2.6 4.7 4.3 2.1 1.6 2.0 1.4 2.4 6.9 5.1 3.6 3.3 1.0 – 5.4 2.0 1.6 – 2.0 2.4 1.4 6.9 5.1 3.6 3.3 1.0 – 5.4 2.0 1.6 – 2.0 2.4 1.4 7.5 5.1 4.1 1.2 1.1 2.8 6.2 2.8 2.0 – 2.0 2.4 1.7 7.5 5.1 4.1 1.2 1.1 2.8 6.2 2.8 2.0 – 2.0 2.4 1.7 Removing the top protective cover or bottom conduit bracket from an IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection while maintaining IP20 conformity. n IP00/Open Type Enclosure Drives W1 4-d t2 4-d W Max W2 D1 D t1 H2 t1 W Max W2 Max W2 Figure 1 Mechanical Installation Max W2 H2 H1 H H t2 H1 W1 D1 D Figure 2 W1 W3 6-d W3 t2 H t1 H2 H1 2 D1 Max W2 W Max W2 D Figure 3 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 45 2.1 Mechanical Installation Table 2.8 Dimensions for IP00/Open Type Enclosure: 200 V Class Drive Model Figure Dimensions (in) W2 H1 H2 D1 t1 t2 d Wt. (lb) W H D W1 17.72 27.76 12.99 12.80 0.39 26.77 0.49 5.12 0.13 0.13 M10 167.6 17.72 27.76 12.99 12.80 0.39 26.77 0.49 5.12 0.13 0.13 M10 176.4 2A0360A <1> 19.69 31.50 13.78 14.57 0.39 30.43 0.51 5.12 0.18 0.18 M12 216.1 2A0415A 19.69 31.50 13.78 14.57 0.39 30.43 0.51 5.12 0.18 0.18 M12 218.3 2A0250A <1> 2A0312A <1> 1 <1> Customers may convert these models to IP20/NEMA Type 1 enclosures using an IP20/NEMA Type 1 Kit. Refer to IP20/NEMA Type 1 Kit Selection on page 47 to select the appropriate kit. Table 2.9 Dimensions for IP00/Open Type Enclosure: 400 V Class Drive Model Dimensions (in) W H D W1 W2 W3 W4 H1 H2 D1 t1 t2 d Wt. (lb) 4A0208A 17.72 27.76 12.99 12.80 0.39 – – 26.77 0.49 5.12 0.13 0.13 M10 174.2 4A0250A 19.69 31.50 13.78 14.57 0.39 – – 30.43 0.51 5.12 0.18 0.18 M12 211.6 19.69 31.50 13.78 14.57 0.39 – – 30.43 0.51 5.12 0.18 0.18 M12 224.9 19.69 31.50 13.78 14.57 0.39 – – 30.43 0.51 5.12 0.18 0.18 M12 235.9 19.69 26.38 26.38 37.40 44.88 44.88 14.57 14.57 14.57 14.57 17.32 17.32 0.31 0.24 0.24 – 8.66 8.66 – – – 36.34 43.70 43.70 0.51 0.59 0.59 5.31 5.91 5.91 0.18 0.18 0.18 0.18 0.18 0.18 M12 M12 M12 275.6 476.2 487.2 Figure <1> <1> 4A0296A 1 <1> 4A0362A <1> 4A0414A 4A0515A 4A0675A 2 3 <1> Customers may convert these models to IP20/NEMA Type 1 enclosures using an IP20/NEMA Type 1 Kit. Refer to IP20/NEMA Type 1 Kit Selection on page 47 to select the appropriate kit. Table 2.10 Dimensions for IP00/Open Type Enclosure: 600 V Class Drive Model Dimensions (in) Figure 5A0125A <1> 5A0145A <1> 5A0192A <1> 5A0242A <1> W H D W1 W2 W3 W4 H1 H2 D1 t1 t2 d Wt. (lb) 17.72 27.76 12.99 12.80 0.39 – – 26.77 0.49 5.12 0.13 0.13 M10 174.2 17.72 27.76 12.99 12.80 0.39 – – 26.77 0.49 5.12 0.13 0.13 M10 174.2 19.69 31.50 13.78 14.57 0.39 – – 30.43 0.51 5.12 0.18 0.18 M12 235.9 19.69 31.50 13.78 14.57 0.39 – – 30.43 0.51 5.12 0.18 0.18 M12 235.9 1 <1> Customers may convert these models to IP20/NEMA Type 1 enclosures using an IP20/NEMA Type 1 Kit. Refer to IP20/NEMA Type 1 Kit Selection on page 47 to select the appropriate kit. 46 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation IP20/NEMA Type 1 Kit Selection Customers may convert IP00/Open Type models to IP20/NEMA Type 1 enclosures. Refer to Table 2.11 to select the appropriate IP20/NEMA Type 1 Kit when performing the conversion. Contact a Yaskawa representative for IP20/NEMA Type 1 Kit availability for IP00/Open Type models not listed. Table 2.11 IP20/NEMA Type 1 Kit Selection IP00/Open Type Drive Model 2A0250A 2A0312A 2A0360A 4A0208A 4A0250A 4A0296A 4A0362A 5A0125A Comments 100-054-503 100-054-504 Refer to IP20/NEMA Type 1 Enclosure Drives on page 41 for drive dimensions with the IP20/NEMA Type 1 Kit installed. 100-054-503 100-054-504 Mechanical Installation 5A0145A 5A0192A 5A0242A IP20/NEMA Type 1 Kit Code 2 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 47 2.1 Mechanical Installation n Flange Type Enclosure (NEMA 12 Backside) Dimensions Unit: inch [mm] Figure 2.12 Models 2A0004U to 0012U, 4A0002U to 0005U, and 5A0003U and 0004U Table 2.12 Weights for 2A0004U to 0012U, 4A0002U to 0005U, and 5A0003U and 0004U Drive Model Drive Weight lb (kg) 48 2A0004U 7.3 (3.3) 2A0006U 7.3 (3.3) 2A0008U 7.5 (3.4) 2A0010U 7.5 (3.4) 2A0012U 4A0002U 4A0004U 4A0005U 5A0003U 5A0004U 7.5 7.5 7.5 7.5 7.5 7.5 (3.4) (3.4) (3.4) (3.4) (3.4) (3.4) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Mechanical Installation 2.1 Mechanical Installation Unit: inch [mm] Figure 2.13 Models 2A0018U and 0021U, 4A0007U to 0011U, and 5A0006U and 0009U 2 Table 2.13 Weights for 2A0018U and 0021U, 4A0007U to 0011U, and 5A0006U and 0009U Drive Model Drive Weight lb (kg) 2A0018U 8.1 (3.7) 2A0021U 8.1 (3.7) 4A0007U 7.9 (3.6) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4A0009U 8.1 (3.7) 4A0011U 8.1 (3.7) 5A0006U 8.1 (3.7) 5A0009U 8.1 (3.7) 49 2.1 Mechanical Installation Unit: inch [mm] [194] Figure 2.14 Models 2A0030U and 0040U, 4A0018U and 0023U, and 5A0011U Table 2.14 Weights for 2A0030U and 0040U, 4A0018U and 0023U, and 5A0011U Drive Model Drive Weight lb (kg) 50 2A0030U 9.2 (4.2) 2A0040U 9.2 (4.2) 4A0018U 9.0 (4.1) 4A0023U 9.0 (4.1) 5A0011U 9.0 (4.1) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Mechanical Installation 2.1 Mechanical Installation Unit: inch [mm] 2 Figure 2.15 Model 4A0031U Table 2.15 Weight for 4A0031U Drive Model Drive Weight lb (kg) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4A0031U 12.5 (5.7) 51 2.1 Mechanical Installation Unit: inch [mm] [234] Figure 2.16 Models 2A0056U, 4A0038U, and 5A0017U and 5A0022U Table 2.16 Weights for 2A0056U, 4A0038U, and 5A0017U and 5A0022U Drive Model Drive Weight lb (kg) 52 2A0056U 13.0 (5.9) 4A0038U 13.2 (6.0) 5A0017U 13.2 (6.0) 5A0022U 13.2 (6.0) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Mechanical Installation 2.1 Mechanical Installation Unit: inch [mm] Figure 2.17 Models 2A0069U and 2A0081U, 4A0044U, and 5A0027U and 5A0032U 2 Table 2.17 Weights for 2A0069U and 2A0081U, 4A0044U, and 5A0027U and 5A0032U Drive Model Drive Weight lb (kg) 2A0069U 20.0 (9.1) 2A0081U 22.0 (10.0) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4A0044U 19.1 (8.7) 5A0027U 19.1 (8.7) 5A0032U 19.1 (8.7) 53 2.1 Mechanical Installation Unit: inch [mm] Figure 2.18 Models 2A0110U and 4A0058U Table 2.18 Weights for 2A0110U and 4A0058U Drive Model Drive Weight lb (kg) 54 2A0110U 50.6 (23.0) 4A0058U 50.6 (23.0) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation Mechanical Installation Unit: inch [mm] Figure 2.19 Models 2A0138U, 4A0072U, 5A0041U and 5A0052U Table 2.19 Weights for 2A0138U, 4A0072U, 5A0041U and 5A0052U Drive Model Drive Weight lb (kg) 2A0138U 61.6 (28.0) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4A0072U 59.4 (27.0) 5A0041U 59.4 (27.0) 5A0052U 59.4 (27.0) 2 55 2.1 Mechanical Installation [390] Unit: inch [mm] Figure 2.20 Models 4A0088U and 4A0103U Table 2.20 Weights for 4A0088U and 4A0103U Drive Model Drive Weight lb (kg) 56 4A0088U 85.8 (39.0) 4A0103U 85.8 (39.0) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation Mechanical Installation Unit: inch [mm] Figure 2.21 Models 2A0169U and 0211U, 4A0139U and 0165U, and 5A0062U to 0099U Table 2.21 Weights for 2A0169U and 0211U, 4A0139U and 0165U, and 5A0062U to 0099U Drive Model Drive Weight lb (kg) 2A0169U 90.2 (41.0) 2A0211U 92.4 (42.0) 4A0139U 99.0 (45.0) 4A0165U 101.2 (46.0) 5A0062U 99.0 (45.0) 5A0077U 99.0 (45.0) 5A0099U 191 (87) 2 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 57 2.1 Mechanical Installation Unit: inch [mm] Figure 2.22 Models 2A0250U and 0312U, 4A0208U, and 5A0125U and 0145U Table 2.22 Weights for 2A0250U and 0312U, 4A0208U, and 5A0125U and 0145U Drive Model Drive Weight lb (kg) 58 2A0250U 183 (83) 2A0312U 194 (88) 4A0208U 191 (87) 5A0125U 191 (87) 5A0145U 191 (87) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation Unit: inch [mm] Mechanical Installation Figure 2.23 Models 2A0360U and 0415U, 4A0250U to 0362U, and 5A0192U and 0242U Table 2.23 Weights for 2A0360U and 0415U, 4A0250U to 0362U, and 5A0192U and 0242U Drive Model Drive Weight lb (kg) 2A0360U 238 (108) 2A0415U – 4A0250U 233 (106) 4A0296U 246 (112) 4A0362U 257 (117) 5A0192U 257 (117) 5A0242U 257 (117) 2 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 59 2.1 Mechanical Installation 0.79 [20] [645] Unit: inch [mm] Figure 2.24 Model 4A0414U 60 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Mechanical Installation 2.1 Mechanical Installation Unit: inch [mm] Figure 2.25 Models 4A0515U and 4A0675U n Flange Type Panel Cut-Out Dimensions Flange type drives must be ordered from the factory using the U: Flange Type enclosure rating. 2 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 61 2.1 Mechanical Installation Unit: inch [mm] Figure 2.26 Models 2A0004U to 0012U, 4A0002U to 0005U, 5A0003U and 0004U 62 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Mechanical Installation 2.1 Mechanical Installation Unit: inch [mm] 2 Figure 2.27 Models 2A0018U and 0021U, 4A0007U to 0011U, and 5A0006U and 0009U YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 63 2.1 Mechanical Installation Unit: inch [mm] Figure 2.28 Models 2A0030U and 0040U, 4A0018U and 0023U, and 5A0011U 64 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Mechanical Installation 2.1 Mechanical Installation 2 Unit: inch [mm] Figure 2.29 Model 4A0031U YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 65 2.1 Mechanical Installation Unit: inch [mm] Figure 2.30 Models 2A0056U, 4A0038U, and 5A0017U and 5A0022U 66 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Mechanical Installation 2.1 Mechanical Installation Unit: inch [mm] 2 Figure 2.31 Models 2A0069U and 2A0081U, 4A0044U, and 5A0027U and 5A0032U YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 67 2.1 Mechanical Installation Unit: inch [mm] Figure 2.32 Models 2A0110U and 4A0058U Unit: inch [mm] Figure 2.33 Models 2A0138U, 4A0072U, and 5A0041U and 5A0052U 68 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation Unit: inch [mm] Mechanical Installation Figure 2.34 Models 4A0088U and 4A0103U 2 Unit: inch [mm] Figure 2.35 Models 2A0169U and 0211U, 4A0139U and 0165U, and 5A0062U to 0099U YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 69 2.1 Mechanical Installation Unit: inch [mm] Figure 2.36 Models 2A0250U and 0312U, 4A0208U, and 5A0125U and 0145U Unit: inch [mm] Figure 2.37 Models 2A0360U and 0415U, 4A0250U and 0362U, and 5A0192U and 0242U 70 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 2.1 Mechanical Installation Unit: inch [mm] Mechanical Installation Figure 2.38 Model 4A0414U 2 Unit: inch [mm] Figure 2.39 Models 4A0515U and 4A0675U YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 71 2.1 Mechanical Installation This Page Intentionally Blank 72 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3 Electrical Installation This chapter explains proper procedures for wiring the control circuit terminals, motor, and power supply. 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 STANDARD CONNECTION DIAGRAM.................................................................74 MAIN CIRCUIT CONNECTION DIAGRAM............................................................77 TERMINAL COVER................................................................................................79 HOA KEYPAD AND FRONT COVER....................................................................81 TOP PROTECTIVE COVER...................................................................................84 MAIN CIRCUIT WIRING.........................................................................................85 CONTROL CIRCUIT WIRING................................................................................96 CONTROL I/O CONNECTIONS...........................................................................101 CONNECT TO A PC.............................................................................................104 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 73 3.1 Standard Connection Diagram 3.1 Standard Connection Diagram Connect the drive and peripheral devices as shown in Figure 3.1. It is possible to set and run the drive via the digital operator without connecting digital I/O wiring. This section does not discuss drive operation; Refer to Start-Up Programming & Operation on page 105 for instructions on operating the drive. NOTICE: Inadequate wiring could result in damage to the drive. Install adequate branch circuit short circuit protection per applicable codes. The drive is suitable for circuits capable of delivering not more than 100,000 RMS symmetrical amperes, 240 Vac maximum (200 V class), 480 Vac maximum (400 V class), 600 Vac maximum (600 V class). NOTICE: When the input voltage is 440 V or higher or the wiring distance is greater than 100 meters, pay special attention to the motor insulation voltage or use a drive duty motor. Failure to comply could lead to motor insulation breakdown. NOTICE: Do not connect AC control circuit ground to drive enclosure. Improper drive grounding can cause control circuit malfunction. Note: 74 The minimum load for the relay outputs M1-M2, M3-M4, MA-MB-MC, and MD-ME-MF is 10 mA. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.1 Standard Connection Diagram DC link choke <1> (option) Terminals -, +1, +2, B1, B2 are for connection options. Never connect power supply lines to these terminals U X +2 Three-Phase Power Supply R 200 to 600 V S 50/60 Hz (Depending on T model capacity) Multi-function digtial inputs (default setting) Braking resistor (option) <2> Jumper +1 B2 B1 - Main Switch Fuse S/L2 T/L3 Forward Run / Stop S1 Through Mode S2 Ext. Pump Fault S3 Fault Reset S4 Multi Setpoint 1 S5 HAND Mode S6 HAND Mode 2 S7 Through Mode S8 M Ground Option board connectors CN5-C CN5-B CN5-A Terminal board jumpers and switches On Off V I DIP Switch S2 Term. Res. On/Off Jumper S1 A1/A2/A3 Volt./Curr. Selection A1 A2 A3 V SN I SC Sink / Source mode selection wire link (default: Sink) <4> W/T3 <3> Control Circuit V W V/T2 iQpump1000 R/L1 U U/T1 Main Circuit Jumper S5 AM/FM Volt./Curr. Selection FM AM SP MA +24 V <5> MB MC Fault output 250 Vac, max. 1 A 30 Vdc, max 1 A (min. 5 Vdc, 10 mA) Shield ground terminal MD RP Pulse Train Input (max 32 kHz) <6> +V ME MF Power supply +10.5 Vdc, max. 20 mA 2 kΩ A1 Analog Input 1 (Frequency Bias H3-02) Multi-function analog/pulse train inputs A2 0 to +/-10Vdc (20 kΩ) 4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω) Analog Input 2 (PID Feedback H3-10) 0 to +10Vdc (20 kΩ) 4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω) M1 M2 <7> M3 M4 0V Multi-function relay output (During Freq. 250 Vac, max. 1 A Output H2-01) 30 Vdc, max 1 A (min. 5 Vdc, 10 mA) Multi-function relay output (Through Mode H2-02) 250 Vac, max. 1 A 30 Vdc, max 1 A (min. 5 Vdc, 10 mA) Electrical Installation A3 Analog Input 3 (HAND Freq. Reference H3-06) 0 to +/-10Vdc (20 kΩ) AC 4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω) <8> Multi-function relay output (Fault H2-03) 250 Vac, max. 1 A 30 Vdc, max 1 A (min. 5 Vdc, 10 mA) Note: When A1 & A3 using current input Resolution = 10 bit plus sign Termination resistor (120 Ω , 1/2 W) R+ R- MEMOBUS/Modbus comm. RS-422/RS-485 max. 115.2 kBps S+ DIP Switch S2 <9> FM IG + <11> 24V shielded line AM AC - FM 3 + (Output frequency) -10 to +10 Vdc (2mA) or 4 to 20 mA <10> Multi-function analog output 2 AM 0V + (Output current) -10 to +10 Vdc (2mA) or 4 to 20 mA <10> E (G) SN Factory Installed Jumper +24 Vdc Transducer - Supply (max. 150 mA) Multi-function analog output 1 - S- AC twisted-pair shielded line control circuit terminal main circuit terminal Figure 3.1 Drive Standard Connection Diagram (example: model 2A0040) <1> Remove the jumper when installing a DC link choke. Models 2A0110 to 2A0415 and 4A0058 to 4A0675 come with a built-in YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 75 3.1 Standard Connection Diagram DC link choke. <2> Set L8-55 to 0 to disable the protection function of the built-in braking transistor of the drive when using an optional regenerative converter or dynamic braking option. Leaving L8-55 enabled may cause a braking resistor fault (rF). Additionally, disable Stall Prevention (L3-04 = 0) when using an optional regenerative converter, regenerative or braking units, or dynamic braking option. Leaving If L3-04 enabled may prevent the drive from stopping within the specified deceleration time. <3> Supplying power to the control circuit separately from the main circuit requires 24 V power supply (option). <4> This figure illustrates an example of a sequence input to S1 through S8 using a non-powered relay or an NPN transistor. Install the wire link between terminals SC-SP for Sink mode, between SC-SN for Source mode, or leave the link out for external power supply. Never short terminals SP and SN, as it will damage the drive. <5> This voltage source supplies a maximum current of 150 mA. <6> The maximum output current capacity for the +V terminal on the control circuit is 20 mA. Never short terminals +V and AC, as it can cause erroneous operation or damage the drive. <7> Set jumper S1 to select between a voltage or current input signal to terminal A2. The default setting is for current input. <8> Set jumper S1 to select between a voltage or current input signal to terminal A1 and A3. The default setting is for voltage input. <9> Set DIP switch S2 to the ON position to enable the termination resistor in the last drive in a MEMOBUS/Modbus network. <10> Monitor outputs work with devices such as analog frequency meters, ammeters, voltmeters, and wattmeters. They are not intended for use as a feedback-type signal. <11> Use jumper S5 to select between voltage or current output signals at terminals AM and FM. Set parameters H4-07 and H4-08 accordingly. WARNING! Sudden Movement Hazard. Do not close the wiring for the control circuit unless the multifunction input terminal parameters are properly set. Improper sequencing of run/stop circuitry could result in death or serious injury from moving equipment. WARNING! Sudden Movement Hazard. Ensure start/stop and safety circuits are wired properly and in the correct state before energizing the drive. Failure to comply could result in death or serious injury from moving equipment. When programmed for 3-Wire control, a momentary closure on terminal S1 may cause the drive to start. WARNING! Sudden Movement Hazard. Confirm the drive I/O signals and external sequence before executing the application preset function. Executing the application preset function or setting A1-03 ≠ 0 will change the drive I/O terminal functions and may cause unexpected equipment operation. Failure to comply may cause death or serious injury. NOTICE: When using the automatic fault restart function with wiring designed to shut off the power supply upon drive fault, make sure the drive does not trigger a fault output during fault restart (L5-02 = 0, default). Failure to comply will prevent the automatic fault restart function from working properly. 76 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.2 Main Circuit Connection Diagram 3.2 Main Circuit Connection Diagram Refer to diagrams in this section when wiring the main circuit of the drive. Connections may vary based on drive capacity. The DC power supply for the main circuit also provides power to the control circuit. NOTICE: Do not use the negative DC bus terminal “–” as a ground terminal. This terminal is at high DC voltage potential. Improper wiring connections could damage the drive. u Three-Phase 200 V Class Models 2A0004 to 2A0081 Three-Phase 400 V Class Models 4A0002 to 4A0044 Three-Phase 600 V Class Models 5A0003 to 5A0032 B1 B2 +1 Relay +2 R/L1 Current sensor U/T1 + S/L2 V/T2 T/L3 W/T3 – Gate board Control board Operator Figure 3.2 Connecting Main Circuit Terminals u Three-Phase 200 V Class Models 2A0110, 2A0138 Three-Phase 400 V Class Models 4A0058, 4A0072 Three-Phase 600 V Class Models 5A0041, 5A0052 Electrical Installation B1 B2 +1 DC link choke Relay Current sensor R/L1 S/L2 U/T1 + V/T2 T/L3 W/T3 – 3 Gate board Control board Operator Figure 3.3 Connecting Main Circuit Terminals YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 77 3.2 Main Circuit Connection Diagram u Three-Phase 200 V Class Models 2A0169 to 2A0211 Three-Phase 400 V Class Models 4A0088 to 4A0139 Three-Phase 600 V Class Models 5A0062 to 5A0099 +3 +1 DC link choke Relay R/L1 Current sensor U/T1 + S/L2 V/T2 T/L3 W/T3 – Gate board Control board Operator Figure 3.4 Connecting Main Circuit Terminals u Three-Phase 200 V Class Models 2A0250 to 2A0415 Three-Phase 400 V Class Models 4A0165 to 4A0675 Three-Phase 600 V Class Models 5A0125 to 5A0242 +3 +1 DC link choke Relay R/L1 Current sensor U/T1 + S/L2 V/T2 T/L3 W/T3 – 24 V Power Supply Gate board Control board Operator Figure 3.5 Connecting Main Circuit Terminals u Single-Phase Connections Use terminals R/L1 and S/L2 to connect single-phase power. 78 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.3 Terminal Cover 3.3 Terminal Cover Follow the procedure below to remove the terminal cover for wiring and to reattach the terminal cover after wiring is complete. u Models 2A0004 to 2A0081, 4A0002 to 4A0044, 5A0003 to 5A0032 (IP20/NEMA Type 1 Enclosure) n Removing the Terminal Cover 1. Loosen the terminal cover screw using a #2 Phillips screwdriver. Screw sizes vary by drive model. Figure 3.6 Removing the Terminal Cover on an IP20/NEMA Type 1 Enclosure Drive 2. Push in on the tab located on the bottom of the terminal cover and gently pull forward to remove the terminal cover. Electrical Installation Figure 3.7 Removing the Terminal Cover on an IP20/NEMA Type 1 Enclosure Drive n Reattaching the Terminal Cover Power lines and signal wiring should pass through the opening provided. Refer to Wiring the Main Circuit Terminal on page 94 and Wiring the Control Circuit Terminal on page 99 for details on wiring. Reattach the terminal cover after completing the wiring to the drive and other devices. 3 <1> Figure 3.8 Reattaching the Terminal Cover on an IP20/NEMA Type 1 Enclosure Drive <1> Connect the ground wiring first, then the main circuit wiring, and finally the control circuit wiring. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 79 3.3 Terminal Cover u Models 2A0110 to 2A0250, 4A0208 to 4A0675, and 5A0125 to 5A0242 (IP00/Open Type Enclosure) n Removing the Terminal Cover 1. Note: Loosen the screws on the terminal cover, then pull down on the cover. The terminal cover and the number of terminal cover screws differ depending on the drive model. CAUTION! Do not completely remove the cover screws, just loosen them. If the cover screws are removed completely, the terminal cover may fall off causing an injury. Figure 3.9 Removing the Terminal Cover on an IP00/Open Type Enclosure Drive 2. Pull forward on the terminal cover to free it from the drive. Figure 3.10 Removing the Terminal Cover on an IP00/Open Type Enclosure Drive n Reattaching the Terminal Cover After wiring the terminal board and other devices, double-check connections and reattach the terminal cover. Refer to Wiring the Main Circuit Terminal on page 94 and Wiring the Control Circuit Terminal on page 99 for details on wiring. <1> Figure 3.11 Reattaching the Terminal Cover on an IP00/Open Type Enclosure Drive <1> Connect the ground wiring first, then the main circuit wiring, and finally the control circuit wiring. 80 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.4 HOA Keypad and Front Cover 3.4 HOA Keypad and Front Cover Detach the HOA keypad from the drive for remote operation or when opening the front cover to install an option card. NOTICE: Be sure to remove the HOA keypad prior to opening or reattaching the front cover. Leaving the HOA keypad plugged into the drive when removing the front cover can result in erroneous operation caused by a poor connection. Firmly fasten the front cover back into place before reattaching the HOA keypad. u Removing/Reattaching the HOA Keypad n Removing the HOA Keypad While pressing on the tab located on the right side of the digital operator, pull the HOA keypad forward to remove it from the drive. Figure 3.12 Removing the HOA Keypad n Reattaching the HOA Keypad Insert the HOA keypad into the opening in the top cover while aligning it with the notches on the left side of the opening. Next, press gently on the right side of the keypad until it clicks into place. u Removing/Reattaching the Front Cover n Removing the Front Cover Models 2A0004 to 2A0081, 4A0002 to 4A0044, and 5A0003 to 5A0032 After removing the terminal cover and the HOA keypad, loosen the screw that affixes the front cover (models 2A0056, 4A0038, 5A0022, and 5A0027 do not use a screw to affix the front cover) . Pinch in on the tabs found on each side of the front cover, then pull forward to remove it from the drive. Electrical Installation Figure 3.13 Reattaching the HOA Keypad 3 Figure 3.14 Remove the Front Cover (2A0004 to 2A0081, 4A0002 to 4A0044, and 5A0003 to 5A0032) Models 2A0110 to 2A0415 and 4A0058 to 4A0675 1. Remove the terminal cover and the HOA keypad. 2. Loosen the installation screw on the front cover. 3. Use a straight-edge screwdriver to loosen the hooks on each side of the cover that hold it in place. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 81 3.4 HOA Keypad and Front Cover Hook Front cover installation screw Hook Free hooks on both sides of the cover Figure 3.15 Remove the Front Cover (2A0010 to 2A0415 and 4A0058 to 4A0675) 4. Unhook the left side of the front cover then swing the left side towards you as shown in Figure 3.16 until the cover comes off. Figure 3.16 Remove the Front Cover (2A0010 to 2A0415 and 4A0058 to 4A0675) 82 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.4 HOA Keypad and Front Cover n Reattaching the Front Cover Models 2A0004 to 2A0081, 4A0002 to 4A0044, and 5A0003 to 5A0032 Reverse the instructions given in Remove the Front Cover (2A0004 to 2A0081, 4A0002 to 4A0044, and 5A0003 to 5A0032) on page 81 to reattach the front cover. Pinch inwards on the hooks found on each side of the front cover while guiding it back into the drive. Make sure it clicks firmly into place. Models 2A0110 to 2A0415 and 4A0058 to 4A0675 1. Slide the front cover so the hooks on the top connect to the drive. Figure 3.17 Reattach the Front Cover (2A0110 to 2A0415 and 4A0058 to 4A0675) After connecting the hooks to the drive, press firmly on the cover to lock it into place. Electrical Installation 2. 3 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 83 3.5 Top Protective Cover 3.5 Top Protective Cover Drive models 2A0004 to 2A0081, 4A0002 to 4A0044, and 5A0003 to 5A0032 are designed to IP20/NEMA Type 1 specifications with a protective cover on the top. Removing this top protective cover or the bottom conduit bracket from an IP20/NEMA Type 1 enclosure drive voids the NEMA Type 1 protection while maintaining IP20 conformity. u Removing the Top Protective Cover Insert the tip of a straight-edge screwdriver into the small opening located on the front edge of the top protective cover. Gently apply pressure as shown in the figure below to free the cover from the drive. Note: Removing the top protective cover or the bottom conduit bracket from an IP20/NEMA Type 1 enclosure drive voids the NEMA Type 1 protection while maintaining IP20 conformity. Figure 3.18 Removing the Top Protective Cover u Reattaching the Top Protective Cover Insert the two small protruding hooks on the rear side of the top protective cover into the provided mounting holes near the back of the drive, then press down on the front side of the top protective cover to fasten the cover into place. Protective Cover Mounting Holes Figure 3.19 Reattaching the Protective Cover 84 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.6 Main Circuit Wiring 3.6 Main Circuit Wiring This section describes the functions, specifications, and procedures required to safely and properly wire the main circuit in the drive. NOTICE: Do not solder the ends of wire connections to the drive. Soldered wiring connections can loosen over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. NOTICE: Do not switch the drive input to start or stop the motor. Frequently switching the drive on and off shortens the life of the DC bus charge circuit and the DC bus capacitors, and can cause premature drive failures. For the full performance life, refrain from switching the drive on and off more than once every 30 minutes. Note: Refer to Single-Phase Derating on page 247 for applying and protecting the drive when using single-phase input power. Refer to Input Fuse Installation on page 347 for details on fuse selection. u Factory Recommended Branch Circuit Protection WARNING! Fire Hazard. Install adequate branch circuit protection according to applicable local codes and this manual. Failure to comply could result in fire and damage to the drive or injury to personnel. The device is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical amperes, 240 Vac (200 V class) and 480 Vac (400 V class), when protected by branch circuit protection devices specified in this manual. Branch circuit protection shall be provided by any of the following: Non-time delay Class J, T, or CC fuses sized at 300% of the drive input rating, or Time delay Class J, T, or CC fuses sized at 175% of the drive input rating, or MCCB sized at 200% maximum of the drive input rating. Yaskawa recommends installing branch circuit protection according to maintain compliance with UL508C. Semiconductor protective type fuses are preferred. Alternate branch circuit protection devices are also listed in this manual. Refer to Factory Recommended Branch Circuit Protection on page 336 for details. u Main Circuit Terminal Functions Table 3.1 Main Circuit Terminal Functions 200 V Class 400 V Class 600 V Class Drive Model R/L1 S/L2 T/L3 U/T1 V/T2 W/T3 B1 B2 +2 +1 – +3 Note: Type 2A0004 to 2A0081 2A0110 to 2A0138 2A0169 to 2A0415 4A0002 to 4A0044 4A0058, 4A0072 4A0088 to 4A0675 5A0003 to 5A0032 5A0041 to 5A0052 5A0062 to 5A0242 Main circuit power supply input Drive output Braking resistor Not available • DC link choke Not available connection (+1, +2) (remove the shorting bar DC power supply • DC power supply between input input (+1, −) +1 and +2) (+1, −) • Braking unit • DC power supply connection (+3, −) input (+1, −) Not available For 200 V class: 100 Ω or less For 400 V class: 10 Ω or less For 600 V class: 10 Ω or less Function Page Connects line power to the drive 75 Connects to the motor 75 Available for connecting a braking resistor or a braking resistor unit option – Electrical Installation Terminal 3 For connecting: • the drive to a DC power supply (terminals +1 and – are not EU/CE or UL approved) • dynamic braking options • a DC link choke – Grounding terminal 94 Use terminals B1 and – when installing a CDBR-type braking unit on drives with built-in braking transistors (Models 2A0004 to 2A0138, 4A0002 to 4A0072, and 5A0003 to 5A0052). YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 85 3.6 Main Circuit Wiring u Protecting Main Circuit Terminals n Insulation Caps or Sleeves Use insulation caps or sleeves when wiring the drive with crimp terminals. Take particular care to ensure that the wiring does not touch nearby terminals or the surrounding case. n Insulation Barrier Insulation barriers are packaged with drive models 4A0414 through 4A0675 to provide added protection between terminals. Yaskawa recommends using the provided insulation barriers to ensure proper wiring. Refer to Figure 3.20 for instructions on placement of the insulation barriers. Insulation Barrier Figure 3.20 Installing Insulation Barriers 86 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.6 Main Circuit Wiring u Wire Gauges and Tightening Torque Use the tables in this section to select the appropriate wires and crimp terminals. Gauges listed in the tables are for use in the United States. Note: 1. Wire gauge recommendations based on drive continuous current ratings (ND) using 75 °C 600 Vac vinyl-sheathed wire assuming ambient temperature within 40 °C and wiring distance less than 100 m. 2. Terminals +1, +2, +3, –, B1 and B2 are for connecting optional devices such as a DC link choke or braking resistor. Do not connect other nonspecific devices to these terminals. • Consider the amount of voltage drop when selecting wire gauges. Increase the wire gauge when the voltage drop is greater than 2% of motor rated voltage. Ensure the wire gauge is suitable for the terminal block. Use the following formula to calculate the amount of voltage drop: Line drop voltage (V) = 3 × wire resistance (Ω/km) × wire length (m) × current (A) × 10-3 • Refer to instruction manual TOBP C720600 00 for braking transistor option or braking resistor option wire gauges. • Use terminals +1 and – when connecting a regenerative converter or a regen unit. NOTICE: Do not connect a braking resistor to terminals +1 or –. Failure to comply may cause damage to the drive circuitry. • Use terminals B1 and – when installing a CDBR-type braking unit on drives with built-in braking transistors (models 2A0004 to 2A0138, 4A0002 to 4A0072, and 5A0003 to 5A0052). NOTICE: Do not connect a braking resistor to terminals +1 or –. Failure to comply may cause damage to the drive circuitry. • Refer to UL Standards Compliance on page 343 for information on UL compliance. Yaskawa recommends using closed-loop crimp terminals on all drive models. UL/cUL approval requires the use of closedloop crimp terminals when wiring the drive main circuit terminals on models 2A0110 to 2A0415 and 4A0058 to 4A0675. Use only the tools recommended by the terminal manufacturer for crimping. Refer to Closed-Loop Crimp Terminal Size on page 343 for closed-loop crimp terminal recommendations. The wire gauges listed in the following tables are Yaskawa recommendations. Refer to local codes for proper wire gauge selections. n Three-Phase 200 V Class Table 3.2 Wire Gauge and Torque Specifications (Three-Phase 200 V Class) 2A0004 2A0006 2A0008 2A0010 2A0012 2A0018 2A0021 Terminal Recomm. Gauge AWG, kcmil Wire Range AWG, kcmil R/L1, S/L2, T/L3 14 14 to 10 U/T1, V/T2, W/T3 14 14 to 10 –, +1, +2 – 14 to 10 B1, B2 – 14 to 10 10 <1> 14 to 10 R/L1, S/L2, T/L3 12 14 to 10 U/T1, V/T2, W/T3 14 14 to 10 –, +1, +2 – 14 to 10 B1, B2 – 14 to 10 10 <1> 14 to 10 R/L1, S/L2, T/L3 10 12 to 10 U/T1, V/T2, W/T3 10 14 to 10 –, +1, +2 – 14 to 10 B1, B2 – 14 to 10 10 <1> 14 to 10 R/L1, S/L2, T/L3 10 12 to 10 U/T1, V/T2, W/T3 10 12 to 10 –, +1, +2 – 12 to 10 B1, B2 – 14 to 10 10 <1> 12 to 10 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Screw Size Tightening Torque N·m (lb.in.) M4 1.2 to 1.5 (10.6 to 13.3) M4 1.2 to 1.5 (10.6 to 13.3) Electrical Installation Drive Model 3 M4 1.2 to 1.5 (10.6 to 13.3) M4 1.2 to 1.5 (10.6 to 13.3) 87 3.6 Main Circuit Wiring Drive Model Terminal R/L1, S/L2, T/L3 2A0030 2A0040 Recomm. Gauge AWG, kcmil Wire Range AWG, kcmil 8 10 to 6 U/T1, V/T2, W/T3 8 10 to 6 –, +1, +2 – 10 to 6 B1, B2 – 14 to 10 8 <1> 10 to 8 R/L1, S/L2, T/L3 6 8 to 6 U/T1, V/T2, W/T3 8 8 to 6 –, +1, +2 – 6 B1, B2 – 12 to 10 8 <1> 10 to 8 Screw Size Tightening Torque N·m (lb.in.) M4 2.1 to 2.3 (18.4 to 20.4) M5 2 to 2.5 (17.7 to 22.1) M4 2.1 to 2.3 (18.4 to 20.4) M5 2 to 2.5 (17.7 to 22.1) M6 5.4 to 6.0 (47.8 to 53.1) R/L1, S/L2, T/L3 4 6 to 4 U/T1, V/T2, W/T3 4 6 to 4 –, +1, +2 – 6 to 4 B1, B2 – 10 to 6 M5 2.7 to 3.0 (23.9 to 26.6) 6 8 to 6 M6 4 to 6 (35.4 to 53.1) M8 9.9 to 11.0 (87.6 to 97.4) 2A0056 R/L1, S/L2, T/L3 3 4 to 3 U/T1, V/T2, W/T3 3 4 to 3 –, +1, +2 – 4 to 3 B1, B2 – 8 to 6 M5 2.7 to 3.0 (23.9 to 26.6) 6 6 to 4 M6 4 to 6 (35.4 to 53.1) M8 9.9 to 11.0 (87.6 to 97.4) 2A0069 R/L1, S/L2, T/L3 2 3 to 2 U/T1, V/T2, W/T3 2 3 to 2 –, +1, +2 – 3 to 2 B1, B2 – 6 M5 2.7 to 3.0 (23.9 to 26.6) 6 6 to 4 M6 4 to 6 (35.4 to 53.1) M8 9 to 11 (79.7 to 97.4) M10 18 to 23 (159 to 204) M8 9 to 11 (79.7 to 97.4) M10 18 to 23 (159 to 204) M10 18 to 23 (159 to 204) 2A0081 2A0110 <2> 2A0138 <2> 2A0169 <2> 2A0211 <2> R/L1, S/L2, T/L3 1/0 3 to 1/0 U/T1, V/T2, W/T3 1/0 3 to 1/0 –, +1 – 2 to 1/0 B1, B2 – 6 to 1/0 6 6 to 4 R/L1, S/L2, T/L3 2/0 1 to 2/0 U/T1, V/T2, W/T3 2/0 1 to 2/0 –, +1 – 1/0 to 3/0 B1, B2 – 4 to 2/0 4 4 R/L1, S/L2, T/L3 4/0 2/0 to 4/0 U/T1, V/T2, W/T3 4/0 3/0 to 4/0 –, +1 – 1 to 4/0 +3 – 1/0 to 4/0 4 4 to 2 R/L1, S/L2, T/L3 1/0 × 2P 1/0 to 2/0 U/T1, V/T2, W/T3 1/0 × 2P 1/0 to 2/0 – 1 to 4/0 – 1/0 to 4/0 4 4 to 1/0 –, +1 +3 88 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.6 Main Circuit Wiring Recomm. Gauge AWG, kcmil Wire Range AWG, kcmil R/L1, S/L2, T/L3 3/0 × 2P 3/0 to 300 U/T1, V/T2, W/T3 3/0 × 2P 3/0 to 300 –, +1 – 3/0 to 300 +3 – 3 Drive Model 2A0250 <2> 2A0312 <2> 2A0360 <2> 2A0415 <2> Terminal Screw Size Tightening Torque N·m (lb.in.) M12 32 to 40 (283 to 354) 2 to 300 M10 18 to 23 (159 to 204) 3 to 300 M12 32 to 40 (283 to 354) M12 32 to 40 (283 to 354) R/L1, S/L2, T/L3 4/0 × 2P 3/0 to 300 U/T1, V/T2, W/T3 3/0 × 2P 3/0 to 300 –, +1 – 3/0 to 300 +3 – 3/0 to 300 M10 18 to 23 (159 to 204) 2 2 to 300 M12 32 to 40 (283 to 354) R/L1, S/L2, T/L3 250 × 2P 4/0 to 600 U/T1, V/T2, W/T3 4/0 × 2P 4/0 to 600 M12 32 to 40 (283 to 354) –, +1 – 250 to 600 +3 – 3/0 to 600 M10 18 to 23 (159 to 204) 1 1 to 350 M12 32 to 40 (283 to 354) M12 32 to 40 (283 to 354) R/L1, S/L2, T/L3 350 × 2P 250 to 600 U/T1, V/T2, W/T3 300 × 2P 300 to 600 –, +1 – 300 to 600 +3 – 3/0 to 600 M10 18 to 23 (159 to 204) 1 1 to 350 M12 32 to 40 (283 to 354) <1> When installing an EMC filter, additional measures must be taken to comply with IEC61800-5-1. Refer to EMC Filter Installation on page 338 for details. <2> Drive models 2A0110 to 2A0415 require the use of UL-Listed closed-loop crimp terminals for UL/cUL compliance. Use only the tools recommended by the terminal manufacturer for crimping. Table 3.3 Wire Gauge and Torque Specifications (Three-Phase 400 V Class) Recomm. Gauge AWG, kcmil Wire Range AWG, kcmil R/L1, S/L2, T/L3 14 14 to 10 U/T1, V/T2, W/T3 14 14 to 10 –, +1, +2 – 14 to 10 B1, B2 – 14 to 10 Drive Model 4A0002 4A0004 4A0005 4A0007 4A0009 4A0011 Terminal 12 14 to 12 R/L1, S/L2, T/L3 14 14 to 10 U/T1, V/T2, W/T3 14 14 to 10 –, +1, +2 – 14 to 10 B1, B2 – 14 to 10 10 14 to 10 R/L1, S/L2, T/L3 12 14 to 10 U/T1, V/T2, W/T3 14 14 to 10 –, +1, +2 – 14 to 10 – 14 to 10 10 14 to 10 B1, B2 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Screw Size Tightening Torque N·m (lb.in.) M4 1.2 to 1.5 (10.6 to 13.3) Electrical Installation n Three-Phase 400 V Class 3 M4 1.2 to 1.5 (10.6 to 13.3) M4 1.2 to 1.5 (10.6 to 13.3) 89 3.6 Main Circuit Wiring Recomm. Gauge AWG, kcmil Wire Range AWG, kcmil R/L1, S/L2, T/L3 10 12 to 6 U/T1, V/T2, W/T3 10 12 to 6 –, +1, +2 – 12 to 6 B1, B2 – 12 to 10 10 14 to 10 R/L1, S/L2, T/L3 10 10 to 6 U/T1, V/T2, W/T3 10 10 to 6 –, +1, +2 – 12 to 6 B1, B2 – 12 to 10 10 12 to 10 Drive Model 4A0018 4A0023 4A0031 4A0038 Terminal Screw Size Tightening Torque N·m (lb.in.) M4 2.1 to 2.3 (18.4 to 20.4) M5 2 to 2.5 (17.7 to 22.1) M4 2.1 to 2.3 (18.4 to 20.4) M5 2 to 2.5 (17.7 to 22.1) R/L1, S/L2, T/L3 8 8 to 6 U/T1, V/T2, W/T3 8 10 to 6 –, +1, +2 – 10 to 6 B1, B2 – 10 to 8 M5 8 10 to 8 M6 R/L1, S/L2, T/L3 6 8 to 6 U/T1, V/T2, W/T3 8 8 to 6 –, +1, +2 – 6 B1, B2 – 10 to 8 M5 6 10 to 6 M6 4 to 6 (35.4 to 53.1) R/L1, S/L2, T/L3 6 6 to 4 U/T1, V/T2, W/T3 6 6 to 4 M6 5.4 to 6.0 (47.8 to 53.1) –, +1, +2 – 6 to 4 B1, B2 – 10 to 8 M5 2.7 to 3.0 (23.9 to 26.6) 6 8 to 6 M6 4 to 6 (35.4 to 53.1) R/L1, S/L2, T/L3 4 6 to 4 U/T1, V/T2, W/T3 4 6 to 4 –, +1 – 6 to 1 M8 B1, B2 – 8 to 4 9 to 11 (79.7 to 97.4) 6 8 to 6 R/L1, S/L2, T/L3 3 4 to 3 U/T1, V/T2, W/T3 3 4 to 3 –, +1 – 4 to 1 M8 B1, B2 – 6 to 3 9 to 11 (79.7 to 97.4) 6 6 R/L1, S/L2, T/L3 2 3 to 1/0 U/T1, V/T2, W/T3 2 3 to 1/0 –, +1 – 3 to 1/0 M8 +3 – 6 to 1/0 9 to 11 (79.7 to 97.4) M8 9 to 11 (79.7 to 97.4) M5 M5 4A0044 4A0058 <1> 4A0072 <1> 4A0088 <1> 4A0103 <1> 90 4 6 to 4 R/L1, S/L2, T/L3 1/0 2 to 1/0 U/T1, V/T2, W/T3 1 2 to 1/0 –, +1 – 3 to 1/0 +3 – 4 to 1/0 4 6 to 4 2.7 to 3.0 (23.9 to 26.6) 4 to 6 (35.4 to 53.1) 2.7 to 3.0 (23.9 to 26.6) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.6 Main Circuit Wiring Wire Range AWG, kcmil R/L1, S/L2, T/L3 3/0 1/0 to 4/0 4A0139 <1> U/T1, V/T2, W/T3 4A0165 <1> 4A0208 <1> 4A0250 <1> 4A0296 <1> 4A0362 <1> 4A0414 <1> <2> 4A0515 <1> <2> 4A0675 <1> <2> Terminal 2/0 1/0 to 4/0 –, +1 – 1/0 to 4/0 +3 – 3 to 4/0 4 4 R/L1, S/L2, T/L3 4/0 3/0 to 4/0 U/T1, V/T2, W/T3 4/0 3/0 to 4/0 –,+1 – 1 to 4/0 +3 – 1/0 to 4/0 4 4 to 2 R/L1, S/L2, T/L3 300 2 to 300 U/T1, V/T2, W/T3 300 2 to 300 –,+1 – 1 to 250 +3 – 3 to 3/0 4 4 to 300 Screw Size Tightening Torque N·m (lb.in.) M10 18 to 23 (159 to 204) M10 18 to 23 (159 to 204) M10 18 to 23 (159 to 204) M10 18 to 23 (159 to 204) M12 32 to 40 (283 to 354) R/L1, S/L2, T/L3 400 1 to 600 U/T1, V/T2, W/T3 400 1/0 to 600 –,+1 – 3/0 to 600 +3 – 1 to 325 2 2 to 350 R/L1, S/L2, T/L3 500 2/0 to 600 U/T1, V/T2, W/T3 500 2/0 to 600 –,+1 – 3/0 to 600 +3 – 1 to 325 M10 18 to 23 (159 to 204) 2 2 to 350 M12 32 to 40 (283 to 354) R/L1, S/L2, T/L3 4/0 × 2P 3/0 to 600 U/T1, V/T2, W/T3 4/0 × 2P 3/0 to 600 M12 32 to 40 (283 to 354) –,+1 – 4/0 to 600 +3 – 3/0 to 600 M10 18 to 23 (159 to 204) 1 1 to 350 M12 32 to 40 (283 to 354) R/L1, S/L2, T/L3 300 × 2P 4/0 to 300 U/T1, V/T2, W/T3 300 × 2P 4/0 to 300 –,+1 – 3/0 to 300 M12 +3 – 3/0 to 300 32 to 40 (283 to 354) 1 1 to 3/0 R/L1, S/L2, T/L3 3/0 × 4P 3/0 to 300 U/T1, V/T2, W/T3 4/0 × 4P 3/0 to 300 –,+1 – 1/0 to 300 +3 – 1/0 to 300 1/0 1/0 to 300 R/L1, S/L2, T/L3 300 × 4P 4/0 to 300 U/T1, V/T2, W/T3 300 × 4P 4/0 to 300 – 1/0 to 300 – 1/0 to 300 2/0 2/0 to 300 –,+1 +3 Electrical Installation Recomm. Gauge AWG, kcmil Drive Model 3 M12 32 to 40 (283 to 354) M12 32 to 40 (283 to 354) <1> Drive models 4A0058 to 4A0675 require the use of UL-Listed closed-loop crimp terminals for UL/cUL compliance. Use only the tools recommended by the terminal manufacturer for crimping. <2> When installing an EMC filter, additional measures must be taken to comply with IEC61800-5-1. Refer to EMC Filter Installation on page 338 for details. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 91 3.6 Main Circuit Wiring n Three-Phase 600 V Class Table 3.4 Wire Gauge and Torque Specifications (Three-Phase 600 V Class) Recomm. Gauge AWG, kcmil Wire Range AWG, kcmil R/L1, S/L2, T/L3 14 14 to 10 U/T1, V/T2, W/T3 14 14 to 10 –, +1, +2 – 14 to 10 Drive Model 5A0003 5A0004 5A0006 5A0009 5A0011 5A0017 5A0022 5A0027 5A0032 5A0041 5A0052 5A0062 92 Terminal B1, B2 – 14 to 10 10 14 to 10 R/L1, S/L2, T/L3 14 14 to 10 U/T1, V/T2, W/T3 14 14 to 10 –, +1, +2 – 14 to 10 B1, B2 – 14 to 10 Screw Size Tightening Torque N·m (lb.in.) M4 1.2 to 1.5 (10.6 to 13.3) M4 1.2 to 1.5 (10.6 to 13.3) M4 1.2 to 1.5 (10.6 to 13.3) M5 2 to 2.5 (17.7 to 22.1) M5 2 to 2.5 (17.7 to 22.1) M6 4 to 6 (35.4 to 53.1) M5 2 to 2.5 (17.7 to 22.1) M6 4 to 6 (35.4 to 53.1) M6 4 to 6 (35.4 to 53.1) 10 12 to 10 R/L1, S/L2, T/L3 10 14 to 6 U/T1, V/T2, W/T3 14 14 to 6 –, +1, +2 – 14 to 6 B1, B2 – 14 to 10 8 12 to 8 R/L1, S/L2, T/L3 10 10 to 6 U/T1, V/T2, W/T3 10 10 to 6 –, +1, +2 – 10 to 6 B1, B2 – 10 to 8 8 12 to 8 R/L1, S/L2, T/L3 8 10 to 6 U/T1, V/T2, W/T3 10 10 to 6 –, +1, +2 – 10 to 6 B1, B2 – 10 to 8 8 10 to 6 R/L1, S/L2, T/L3 6 6 to 4 U/T1, V/T2, W/T3 6 6 to 4 –, +1, +2 – 6 to 4 B1, B2 – 10 to 8 M5 2 to 2.5 (17.7 to 22.1) 6 10 to 6 M6 4 to 6 (35.4 to 53.1) R/L1, S/L2, T/L3 6 10 to 3 U/T1, V/T2, W/T3 6 10 to 3 –, +1 – 6 to 1 M8 B1, B2 – 12 to 3 9 to 11 (79.7 to 97.4) 6 6 R/L1, S/L2, T/L3 4 10 to 3 U/T1, V/T2, W/T3 6 10 to 3 –, +1 – 6 to 1 M8 B1, B2 – 8 to 3 9 to 11 (79.7 to 97.4) M10 18 to 23 (159 to 204) 6 6 R/L1, S/L2, T/L3 4 10 to 4/0 U/T1, V/T2, W/T3 4 10 to 4/0 –, +1 – 4 to 4/0 +3 – 6 to 4/0 4 4 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Recomm. Gauge AWG, kcmil Wire Range AWG, kcmil R/L1, S/L2, T/L3 3 10 to 4/0 U/T1, V/T2, W/T3 3 10 to 4/0 –, +1 – 3 to 4/0 +3 – 6 to 4/0 4 4 R/L1, S/L2, T/L3 1/0 10 to 4/0 U/T1, V/T2, W/T3 1 10 to 4/0 –, +1 – 2 to 4/0 +3 – 4 to 4/0 4 4 R/L1, S/L2, T/L3 2/0 1 to 300 U/T1, V/T2, W/T3 2/0 1 to 300 –, +1 – 2/0 to 3/0 +3 – 1 to 1/0 Drive Model 5A0077 5A0099 5A0125 5A0145 Terminal Screw Size Tightening Torque N·m (lb.in.) M10 18 to 23 (159 to 204) M10 18 to 23 (159 to 204) M10 18 to 23 (159 to 204) M10 18 to 23 (159 to 204) M12 32 to 40 (283 to 354) 3 4 to 300 R/L1, S/L2, T/L3 3/0 2/0 to 300 U/T1, V/T2, W/T3 3/0 2/0 to 300 –, +1 – 3/0 to 4/0 +3 – 1/0 to 2/0 3 4 to 300 R/L1, S/L2, T/L3 300 2/0 to 600 U/T1, V/T2, W/T3 250 2/0 to 600 –, +1 – 2/0 to 400 +3 – 2/0 to 250 M10 18 to 23 (159 to 204) 1 1 to 350 M12 32 to 40 (283 to 354) R/L1, S/L2, T/L3 400 2/0 to 600 U/T1, V/T2, W/T3 350 2/0 to 600 M12 32 to 40 (283 to 354) –, +1 – 2/0 to 500 +3 – 250 to 300 M10 18 to 23 (159 to 204) 1 1 to 350 M12 32 to 40 (283 to 354) 5A0192 5A0242 u Main Circuit Terminal and Motor Wiring This section outlines the various steps, precautions, and checkpoints for wiring the main circuit terminals and motor terminals. WARNING! Electrical Shock Hazard. Do not connect the AC power line to the output terminals of the drive. Failure to comply could result in death or serious injury by fire as a result of drive damage from line voltage application to output terminals. NOTICE: When connecting the motor to the drive output terminals U/T1, V/T2, and W/T3, the phase order for the drive and motor should match. Failure to comply with proper wiring practices may cause the motor to run in reverse if the phase order is backward. NOTICE: Do not connect phase-advancing capacitors or LC/RC noise filters to the output circuits. Failure to comply could result in damage to the drive, phase-advancing capacitors, LC/RC noise filters or ground fault circuit interrupters. n Cable Length Between Drive and Motor Voltage drop along the motor cable may cause reduced motor torque when the wiring between the drive and the motor is too long, especially at low frequency output. This can also be a problem when motors are connected in parallel with a fairly long motor cable. Drive output current will increase as the leakage current from the cable increases. An increase in leakage current may trigger an overcurrent situation and weaken the accuracy of the current detection. Adjust the drive carrier frequency according to Table 3.5. If the motor wiring distance exceeds 100 m because of the system configuration, reduce the ground currents. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 93 Electrical Installation 3.6 Main Circuit Wiring 3 3.6 Main Circuit Wiring Table 3.5 Cable Length Between Drive and Motor Cable Length Carrier Frequency Note: 50 m or less 15 kHz or less 100 m or less 5 kHz or less Greater than 100 m 2 kHz or less When setting carrier frequency for drives running multiple motors, calculate cable length as the total wiring distance to all connected motors. n Ground Wiring Follow the precautions below when wiring the ground for one drive or a series of drives. WARNING! Electrical Shock Hazard. Make sure the protective earthing conductor complies with technical standards and local safety regulations. Because the leakage current exceeds 3.5 mA in models 4A0414 and larger, IEC 61800-5-1 states that either the power supply must be automatically disconnected in case of discontinuity of the protective earthing conductor or a protective earthing conductor with a cross-section of at least 10 mm2 (Cu) or 16 mm2 (Al) must be used. Failure to comply may result in death or serious injury. WARNING! Electrical Shock Hazard. Always use a ground wire that complies with technical standards on electrical equipment and minimize the length of the ground wire. Improper equipment grounding may cause dangerous electrical potentials on equipment chassis, which could result in death or serious injury. WARNING! Electrical Shock Hazard. Be sure to ground the drive ground terminal (200 V class: ground to 100 Ω or less; 400 V class: ground to 10 Ω or less; 600 V class: ground to 10 Ω or less). Improper equipment grounding could result in death or serious injury by contacting ungrounded electrical equipment. NOTICE: Do not share the ground wire with other devices such as welding machines or large-current electrical equipment. Improper equipment grounding could result in drive or equipment malfunction due to electrical interference. NOTICE: When using more than one drive, ground multiple drives according to instructions. Improper equipment grounding could result in abnormal operation of drive or equipment. Refer to Figure 3.21 when using multiple drives. Do not loop the ground wire. Figure 3.21 Multiple Drive Wiring n Wiring the Main Circuit Terminal WARNING! Electrical Shock Hazard. Shut off the power supply to the drive before wiring the main circuit terminals. Failure to comply may result in death or serious injury. Wire the main circuit terminals after the terminal board has been properly grounded. Models 2A0004 to 2A0081, 4A0002 to 4A0044, and 5A0003 to 5A0032 have a cover placed over the DC bus and braking circuit terminals prior to shipment to help prevent miswiring. Use wire cutters to cut away covers as needed for terminals. B1 B2 A B R/L1 S/L2 T/L3 A – Braking circuit protective cover _ +1 +2 U/T1 V/T2 W/T3 B – DC bus protective cover Figure 3.22 Protecting Cover to Prevent Miswiring (Model 5A0011) 94 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.6 Main Circuit Wiring n Main Circuit Connection Diagram Refer to Main Circuit Connection Diagram on page 77 when wiring terminals on the main power circuit of the drive. Electrical Installation WARNING! Fire Hazard. The braking resistor connection terminals are B1 and B2. Do not connect braking resistors to any other terminals. Improper wiring connections could cause the braking resistor to overheat and cause death or serious injury by fire. Failure to comply may result in damage to the braking circuit or drive. 3 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 95 3.7 Control Circuit Wiring 3.7 Control Circuit Wiring u Control Circuit Terminal Block Functions Drive parameters determine which functions apply to the multi-function digital inputs (S1 to S8), multi-function digital outputs (M1 to M4), multi-function analog inputs (A1 to A3), and multi-function analog monitor output (FM, AM). The default setting is listed next to each terminal in Figure 3.1 on page 75. WARNING! Sudden Movement Hazard. Always check the operation and wiring of control circuits after being wired. Operating a drive with untested control circuits could result in death or serious injury. WARNING! Sudden Movement Hazard. Confirm the drive I/O signals and external sequence before starting test run. Setting parameter A1-03 may change the I/O terminal function automatically from the factory setting. Refer to Application Selection on page . Failure to comply may result in death or serious injury. n Input Terminals Table 3.6 lists the input terminals on the drive. Text in parenthesis indicates the default setting for each multi-function input. Table 3.6 Control Circuit Input Terminals Type No. S1 Multi-Function Digital Inputs Terminal Name (Function) Multi-function input 1 (Closed: Forward run, Open: Stop) Function (Signal Level) Default Setting S2 Multi-function input 2 (Through mode) S3 Multi-function input 3 (External pump fault, N.O.) S4 Multi-function input 4 (Fault reset) S5 Multi-function input 5 (Multi setpoint 1) S6 Multi-function input 6 (HAND mode) S7 Multi-function input 7 (HAND mode 2) S8 Multi-function input 8 (Through mode) SC SP Multi-function input common Digital input power supply +24 Vdc Multi-function input common 24 Vdc power supply for digital inputs, 150 mA max 101 SN Digital input power supply 0 V 24 V transducer power supply 0 V NOTICE: Do not jumper or short terminals SP and SN. Failure to comply will damage the drive. 101 RP Multi-function pulse train input (Frequency reference) +V • Photocoupler • 24 Vdc, 8 mA • Refer to Sinking/Sourcing Mode Switch for Digital Inputs on page 101. • Input frequency range: 0 to 32 kHz • Signal Duty Cycle: 30 to 70% • High level: 3.5 to 13.2 Vdc, low level: 0.0 to 0.8 Vdc • Input impedance: 3 kΩ 10.5 Vdc (max allowable current 20 mA) Power supply for analog inputs 24 V +24 Vdc transducer power supply for customer 150 mA maximum capacity use • -10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ) Analog Inputs / A1 Multi-function analog input 1 • 4 to 20 mA, 0 to 20 mA (input impedance: 250 Ω) (Frequency reference bias) Pulse Train • Voltage or current input must be selected by jumper S1 and H3-01. Input • -10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ) analog input 2 A2 Multi-function • 4 to 20 mA, 0 to 20 mA (input impedance: 250 Ω) (PID feedback) • Voltage or current input must be selected by jumper S1 and H3-09. • -10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ) analog input 3 A3 Multi-function • 4 to 20 mA, 0 to 20 mA (input impedance: 250 Ω) (HAND frequency reference) • Voltage or current input must be selected by jumper S1 and H3-05. AC Frequency reference common 0V E (G) Ground for shielded lines and option cards – 96 Page 276 153 288 151 – 151 160 151 151 162 151 151 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.7 Control Circuit Wiring n Output Terminals Table 3.7 lists the output terminals on the drive. Text in parenthesis indicates the default setting for each multi-function output. Table 3.7 Control Circuit Output Terminals Type Fault Relay Output Multi-Function Digital Output <1> Monitor Output No. MA MB MC MD ME MF M1 M2 M3 M4 FM AM AC Terminal Name (Function) Function (Signal Level) Default Setting N.O. N.C. output Fault output common N.O. N.C. Output Common (Speed agree) 30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A Minimum load: 5 Vdc, 10 mA Page 159 30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A Minimum load: 5 Vdc, 10 mA 159 Multi-function digital output (During frequency output) 30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A Minimum load: 5 Vdc, 10 mA Multi-function digital output (Through mode) Analog monitor output 1 (Output frequency) -10 to +10 Vdc, or 0 to +10 Vdc Analog monitor output 2 (Output current) Monitor common 286 0V – <1> Refrain from assigning functions to digital relay outputs that involve frequent switching, as doing so may shorten relay performance life. Switching life is estimated at 200,000 times (assumes 1 A, resistive load). Connect a suppression diode as shown in Figure 3.23 when driving a reactive load such as a relay coil. Ensure the diode rating is greater than the circuit voltage. B A C D A – External power, 48 V max. B – Suppression diode C – Coil D – 50 mA or less Figure 3.23 Connecting a Suppression Diode n Serial Communication Terminals MEMOBUS/Modbus Communication <1> No. R+ RS+ SIG Signal Name Communications input (+) Communications input (-) Communications output (+) Communications output (-) Shield ground Function (Signal Level) RS-422/RS-485 MEMOBUS/Modbus communication: Use an MEMOBUS/Modbus RS-422 or RS-485 cable to connect the drive. communication protocol 115.2 kbps (max.) 0V <1> Enable the termination resistor in the last drive in a MEMOBUS/Modbus network by setting DIP switch S2 to the ON position. Refer to Control I/O Connections on page 101 for more information on the termination resistor. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 97 Electrical Installation Table 3.8 Control Circuit Terminals: Serial Communications Type 3 3.7 Control Circuit Wiring u Terminal Configuration The control circuit terminals are arranged as shown in Figure 3.24. E(G) IG R+ R- S+ S- M1 M2 M3 M4 V+ AC A1 A2 A3 FM AM AC RP AC 24V E(G) IG R+ R- S+ S- MD ME MF M1 M2 M3 M4 V+ AC A1 A2 A3 FM AM AC RP AC 24V S1 S2 S3 S4 S5 S6 S7 S8 SN SC SP MD ME MF S1 S2 S3 S4 S5 S6 S7 S8 SN SC SP MA MB MC MA MB MC Figure 3.24 Control Circuit Terminal Arrangement n Wire Size and Torque Specifications Select appropriate wire type and gauges from Table 3.9. For simpler and more reliable wiring, use crimp ferrules on the wire ends. Refer to Table 3.10 for ferrule terminal types and sizes. Table 3.9 Wire Gauges Terminal Screw Size Tightening Torque N•m (lb. in) S1-S8, SC, SN, SP RP, V+, A1, A2, A3, AC, 24 V MA, MB, MC, MD, ME, MF M1-M4 FM, AM, AC R+, R-, S+, S-, IG 98 M3 0.5 to 0.6 (4.4 to 5.3) Bare Wire Terminal Applicable Recomm. wire size wire size mm2 (AWG) mm2 (AWG) Stranded wire: 0.2 to 1.0 (24 to 16) Solid wire: 0.2 to 1.5 (24 to 16) 0.75 (18) Ferrule-Type Terminal Applicable Recomm. wire size wire size mm2 (AWG) mm2 (AWG) 0.25 to 0.5 (24 to 20) 0.5 (20) Wire Type Shielded wire, etc. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.7 Control Circuit Wiring n Ferrule-Type Wire Terminals Yaskawa recommends using CRIMPFOX 6, a crimping tool manufactured by PHOENIX CONTACT, to prepare wire ends with insulated sleeves before connecting to the drive. See Table 3.10 for dimensions. L 8 mm d1 d2 Figure 3.25 Ferrule Dimensions Table 3.10 Ferrule Terminal Types and Sizes Size mm2 (AWG) 0.25 (24) 0.34 (22) 0.5 (20) Type L (mm) d1 (mm) d2 (mm) Manufacturer AI 0.25-8YE AI 0.34-8TQ AI 0.5-8WH or AI 0.5-8OG 12.5 10.5 0.8 0.8 1.8 1.8 PHOENIX CONTACT 14 1.1 2.5 u Wiring the Control Circuit Terminal This section describes the proper procedures and preparations for wiring the control terminals. WARNING! Electrical Shock Hazard. Do not remove covers or touch the circuit boards while the power is on. Failure to comply could result in death or serious injury. NOTICE: Separate control circuit wiring from main circuit wiring (terminals R/L1, S/L2, T/L3, B1, B2, U/T1, V/T2, W/T3, -, +1, +2) and other high-power lines. Improper wiring practices could result in drive malfunction due to electrical interference. NOTICE: Separate wiring for digital output terminals MA, MB, MC, MD, ME, MF and M1 to M4 from wiring to other control circuit lines. Improper wiring practices could result in drive or equipment malfunction or nuisance trips. NOTICE: Use a class 2 power supply when connecting to the control terminals. Improper application of peripheral devices could result in drive performance degradation due to improper power supply. Refer to NEC Article 725 Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power Limited Circuits for requirements concerning class 2 power supplies. NOTICE: Connect the shield of shielded cable to the appropriate ground terminal. Improper equipment grounding could result in drive or equipment malfunction or nuisance trips. NOTICE: Do not tighten screws beyond the specified tightening torque. Failure to comply may result in erroneous operation, damage to the terminal block, or cause a fire. NOTICE: Use shielded twisted-pair cables as indicated to prevent operating faults. Improper wiring practices could result in drive or equipment malfunction due to electrical interference. Wire the control circuit only after terminals have been properly grounded and main circuit wiring is complete. Refer to Terminal Board Wiring Guide on page 100 for details. Prepare the ends of the control circuit wiring as shown in Figure 3.28. Refer to Wire Gauges on page 98. Connect control wires as shown in Figure 3.26 and Figure 3.27. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Electrical Installation NOTICE: Insulate shields with tape or shrink tubing to prevent contact with other signal lines and equipment. Improper wiring practices could result in drive or equipment malfunction due to short circuit. 3 99 3.7 Control Circuit Wiring A Preparing wire terminal ends C D B A – Loosen screw to insert wire. B – Single wire or stranded wire C – Avoid fraying wire strands when stripping insulation from wire. Strip length 5.5 mm. D – Blade depth of 0.4 mm or less Blade width of 2.5 mm or less Figure 3.26 Terminal Board Wiring Guide Figure 3.27 Terminal Board Location Inside the Drive When setting the frequency by analog reference from an external potentiometer, use shielded twisted-pair wires (preparing wire ends as shown in Figure 3.28) and connect the shield to the ground terminal of the drive. A E B C D A – Drive side B – Insulation C – Control device side D – Shield sheath (insulate with tape) E – Shield Figure 3.28 Preparing the Ends of Shielded Cables NOTICE: The analog signal wiring between the drive and the operator station or peripheral equipment should not exceed 50 meters when using an analog signal from a remote source to supply the frequency reference. Failure to comply could result in poor system performance. 100 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.8 Control I/O Connections 3.8 Control I/O Connections u Sinking/Sourcing Mode Switch for Digital Inputs Use the wire jumper between terminals SC and SP or SC and SN to select between Sink mode, Source mode or external power supply for the digital inputs S1 to S8 as shown in Table 3.11 (Default: Sink mode, internal power supply). NOTICE: Do not short terminals SP and SN. Failure to comply will damage the drive. Table 3.11 Digital Input Sink/Source/External Power Supply Selection Mode Sinking Mode (NPN) Drive Internal Power Supply (Terminals SN and SP) External 24 Vdc Power Supply S7 S7 S8 S8 SN SN SC SC 24 Vdc 24 Vdc SP Sourcing Mode (PNP) External 24 Vdc SP S7 S7 S8 S8 SN SN SC SC 24 Vdc External 24 Vdc 24 Vdc SP Electrical Installation SP 3 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 101 3.8 Control I/O Connections u Terminals A1, A2, and A3 Input Signal Selection Terminals A1, A2, and A3 can be used to input either a voltage or a current signal. Select the signal type using jumper S1 as explained in Table 3.12. Set parameters H3-01, H3-05, and H3-09 accordingly as shown in Table 3.13. Note: If terminals A1 and A2 are both set for frequency bias (H3-02 = 0 and H3-10 = 0), both input values will be combined to create the frequency reference. Jumper S1 V I A1 A2 A3 Figure 3.29 Terminal A2 Set to Current Input; A1 and A3 Set to Voltage Input Table 3.12 Jumper S1 Settings Setting V (top position) I (bottom position) Description Voltage input (-10 to +10 V or 0 to 10 V) Current input (4 to 20 mA or 0 to 20 mA) Table 3.13 Voltage/Current Selection Parameter Details No. Parameter Name H3-01 Terminal A1 signal level selection H3-05 Terminal A3 signal level selection H3-09 Terminal A2 signal level selection 102 Description Selects the signal level for terminal A1. 0: 0 to 10 Vdc 1: 0 to 10 Vdc Bipolar 2: 4 to 20 mA 3: 0 to 20 mA Selects the signal level for terminal A3. 0: 0 to 10 Vdc 1: 0 to 10 Vdc Bipolar 2: 4 to 20 mA 3: 0 to 20 mA Selects the signal level for terminal A2. 0: 0 to 10 Vdc 1: 0 to 10 Vdc Bipolar 2: 4 to 20 mA 3: 0 to 20 mA Setting Range Default Setting 0 to 3 0 0 to 3 0 0 to 3 2 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 3.8 Control I/O Connections u Terminal AM/FM Signal Selection The signal type for terminals AM and FM can be set to either voltage or current output using jumper S5 on the terminal board as explained in Table 3.14. When changing the setting of jumper S5, parameters H4-07 and H4-08 must be set accordingly. The default selection is voltage output for both terminals. Table 3.14 Jumper S5 Settings Terminal Voltage Output Current Output V Terminal AM V I I FM AM FM AM V Terminal FM V I I FM AM FM AM Table 3.15 Parameter H4-07 and H4-08 Details No. Parameter Name Terminal AM signal level selection H4-08 Terminal FM signal level selection 0: 0 to 10 Vdc 1: -10 to 10 Vdc 2: 4 to 20 mA Setting Range Default Setting 0 to 2 0 Electrical Installation H4-07 Description 3 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 103 3.9 Connect to a PC 3.9 Connect to a PC This drive is equipped with a USB port (type-B). The drive can connect to a USB port on a PC using a USB 2.0, AB-type cable (sold separately). After connecting the drive to a PC, Yaskawa SCADA software for iQpump can be used to monitor drive performance and manage parameter settings. A complementary version of the SCADA software is available for download on our website at iqpump.yaskawa.com. USB Cable (Type-AB) (Type-B) (Type-A) PC Figure 3.30 Connecting to a PC (USB) 104 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4 Start-Up Programming & Operation This chapter explains startup procedures, HOA keypad functions, gives instructions on programming the drive for initial operation, and other important functions. 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 DRIVE START-UP PREPARATION.....................................................................106 POWERING UP THE DRIVE................................................................................108 USING THE HOA KEYPAD.................................................................................111 PUMP APPLICATION PRESETS........................................................................118 IQPUMP PRESETS AND FUNCTIONS...............................................................120 BASIC IQPUMP SETUP AND APPLICATION PRESET PARAMETERS...........149 TEST RUN WITH NO LOAD................................................................................171 TEST RUN WITH LOAD CONNECTED...............................................................172 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 105 4.1 Drive Start-Up Preparation 4.1 Drive Start-Up Preparation To provide the most reliable iQpump1000 drive available and to avoid any extra costs related to loss or reduction of warranty coverage, an authorized Yaskawa service representative should complete this start-up procedure. Please complete the following checklist and maintain it in a secure location, as technical service personnel may request information from this checklist. Note: Refer to Powering Up the Drive on page 108 prior to powering up the drive for the first time. Date:____________________________________________ Start-Up Person: Company Name:_________________________________ Start-Up Location: _________________________________ Sales Order #: ___________________________________ Serial #: _________________________________________ Printed Name: ___________________________________ Drive Location: ___________________________________ Phone #: _______________________________________ Signature: _______________________________________ Owner’s Representative: Printed Name: ___________________________________ Phone #: _________________________________________ Company: ______________________________________ Signature: ________________________________________ u Start-Up Checklist 106 No. Item 1 The drive is thoroughly tested at the factory. The start up person should verify that the drive is free of shipping and installation damage. Shipping damage is not covered by the Yaskawa warranty. Claims must be filed with the shipping company as soon as possible for any potential recovery via insurance. 2 Review the iQpump simplified setup procedure shipped with the drive. Refer to Simple Setup Procedure on page 3 for another version of this document. 3 Verify that the model number and voltage ratings in the purchase order match the nameplate data for each unit. 4 The location of the drive is important to achieve proper performance and normal operating life. Refer to Installation Environment on page 34 for details. 5 Ensure the drive is on a vertical surface with adequate space for air circulation. Refer to Correct Installation Spacing on page 35 for proper spacing. 6 Verify that the proper branch circuit protection is installed in front of the drive. Refer to Factory Recommended Branch Circuit Protection on page 336 for proper input fuse or circuit breaker sizing. 7 NOTICE: Separate control circuit wiring from main circuit wiring (terminals R/L1, S/L2, T/L3, B1, B2, U/T1, V/T2, W/T3, -, +1, +2) and other high-power lines. Improper wiring practices could result in drive malfunction due to electrical interference. 8 NOTICE: Insulate shields with tape or shrink tubing to prevent contact with other signal lines and equipment. Improper wiring practices could result in drive or equipment malfunction due to short circuit. 9 WARNING! Electrical Shock Hazard. Do not connect the AC power line to the output terminals of the drive. Failure to comply could result in death or serious injury by fire as a result of drive damage from line voltage application to output terminals. 10 NOTICE: Do not connect phase-advancing capacitors or LC/RC noise filters to the output circuits. Failure to comply could result in damage to the drive, phase-advancing capacitors, LC/RC noise filters or ground fault circuit interrupters. 11 Use crimp insulated terminals or insulated shrink tubing for wiring connections. Wires should have a continuous maximum allowable temperature of 75 °C 600 Vac UL-approved vinyl-sheathed insulation. Consider the amount of voltage drop when selecting wire gauges. Increase the wire gauge when the voltage drop is greater than 2% of motor rated voltage. Ensure the wire gauge is suitable for the terminal block. Use the following formula to calculate the amount of voltage drop: Line drop voltage (V) = 3 × wire resistance (Ω/km) × wire length (m) × current (A) × 10-3 12 If the cable between the drive and motor exceeds 50 m (164 ft.), adjust the carrier frequency set C6-02 accordingly. 13 Determine proper wire size for power and motor leads. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.1 Drive Start-Up Preparation No. 14 Item WARNING! Always ground the ground terminal. (200 V Class: Ground to 100 Ω or less, 400 V Class: Ground to 10 Ω or less). Improper equipment grounding could result in death or serious injury by contacting ungrounded electrical equipment. When using multiple drives, ground each drive directly or daisy-chain to the ground pole(s). DO NOT FORM A LOOP WITH THE GROUND LEADS. Refer to Multiple Drive Wiring on page 94. Review terminal functions of signal and control circuits. 16 Verify if any customer safety devices are required (e.g. External Pump Fault). 17 Record the following motor nameplate information: Voltage: _____________________Motor Rated Amps: ____________________ 18 Verify that the commercial power supply is within the rated drive input voltage: Power Supply: ____________________Vac Drive Input Voltage: ____________________Vac 19 Determine whether three-phase input power or single-phase input power is to be used. Refer to Single-Phase Derating on page 247 for additional application information if using single-phase. 19 Verify that the leads in the three-phase electric motor conduit box are configured for the proper voltage. 20 Ensure Motor Rated Current is less than or equal to drive output amps. If multiple motors are being used, make sure that the Motor Rated Current sum is less than or equal to drive output amp rating. Please note that if multiple motors are being operated from one drive, each motor must have its own overload and short circuit protection. 21 Wire all necessary power leads to the drive. DO NOT CONNECT MOTOR TO DRIVE AT THIS TIME. 22 Wire all necessary ground wires to the drive. 23 Wire all necessary control wires to the drive. 24 Ensure that the power leads are connected to the R/L1, S/L2 and T/L3 terminals in the drive. Confirm single-phase input or threephase input wiring. 25 Tighten all of the three-phase power and ground connections. Please check that all control and signal terminations are tight. 26 Inspect the control circuit connections (including the shield) and determine if a motor safety circuit is connected. If normally closed, these contacts may be wired in series with the RUN command contacts, which are between terminals S1 and SN of the drive. No special programming is required. Alternately, these contacts could be wired between terminals S3 and SN as External Fault Inputs, and may be either normally closed or normally open contacts. 27 Record any other connections to the drive to determine if special programming is required for the following: Multi-function Inputs Multi-function Outputs Multi-function Digital Inputs Multi-function Analog Outputs Network Communications Refer to Parameter List on page 255 for details. Start-Up Programming & Operation 15 4 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 107 4.2 Powering Up the Drive 4.2 Powering Up the Drive Review the following table before applying power. Item to Check Description 200 V class: Three-phase/Single-phase 200 to 240 Vac 50/60 Hz 400 V class: Three-phase/Single-phase 380 to 480 Vac 50/60 Hz 600 V class: Three-phase/Single-phase 500 to 600 Vac 50/60 Hz Power supply voltage Properly wire the power supply input terminals (R/L1, S/L2, T/L3) for three-phase and (R/L1, S/L2) for single-phase. Check for proper grounding of drive and motor. Drive output terminals and motor terminals Control circuit terminals Drive control terminal status Status of the load and connected machinery Properly wire drive output terminals U/T1, V/T2, and W/T3 with motor terminals U, V, and W. Check control circuit terminal connections. Open all control circuit terminals (off). Decouple the motor from the load. u Setting the Real Time Clock When the drive is powered up for the first time, the time and date must be set. The HOA keypad will display the time and date setup screen for 30 seconds. If a button is not pressed during this time, the display will clear and a “Clock Not Set” alarm will flash. Pressing the F2 (Data) key will display the setting screen again. n Feedback Loss Wire Break Alarm If there is no sensor wired to the drive, a “Feedback Loss – Wire Break” alarm will flash on the display after the 30-second time and date screen has elapsed (not the “Clock Not Set” alarm). Providing the proper feedback device signal will clear the Feedback Loss alarm. The “Clock Not Set” alarm will then flash. The drive requires a feedback device (e.g., pressure transducer, flow meter, etc.) to perform automatic system regulation. Any analog 0~10 V or 4-20 mA feedback device can be used in combination with the drive. Note: The factory default setting for the drive is 4~20 mA feedback device connected to analog input A2. n Real Time Clock Setting Display Note: Setting the Real-Time Clock will clear a “TIM” alarm. YYYY/MM/DD HH:MM 20 1 0/01/01 00:00 Second per month + 0 sec FWD A – Real Time Clock Setting Display Set in 24-Hour Clock Time A B B – Gain/Loss Adjustment Display Figure 4.1 Real Time Clock Adjustment Display Display YYYY MM DD HH:MM Second per month 108 Description Set the year with the last two digits. Set the month with two digits. Set the day with two digits. Set the hours and minutes, with two digits for each. Note: Set in 24-hour clock time. After initial setup, the time will display in 12-hour clock time. Set the gain or loss in seconds per month. Note: This does not need to be set for the RTC to function properly. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.2 Powering Up the Drive Moving the Cursor Pressing the F2 key or the RESET key will move the cursor to the digit on the right. Pressing the F1 key will move the cursor to the left. Changing Settings • Changing YYYY/MM/DD HH:MM: Pressing the up arrow key will increase the number selected by the cursor from 0 to 9. Pressing the down arrow key will decrease the number selected by the cursor from 0 to 9. • Setting the Seconds per Month:This setting does not need to be adjusted. Pressing the up arrow key will increase the number selected by the cursor from -504 to +488 in increments of 8. Pressing the down arrow key will decrease the number selected by the cursor from -504 to +488 in increments of 8. The feature is used to keep the RTC in sync with an external device clock, like a PLC or BAS system, and will adjust the clock by a set amount of seconds every month. n Real-Time Clock Setting at Initial Power-up of a New Drive Setting the Real-time clock is required at power-up of a new drive or after digital operator battery replacement. Table 4.1 illustrates how to set the Real-Time Clock at initial power-up of a new drive. Table 4.1 Clock Adjustment Procedure at Power-up of a New Drive Procedure Display ALM 1 Turn the power on. The Real Time Clock Adjustment Display will appear. Use the right arrow key to select the desired digit, then set the correct date and 24-hour clock time using the up and down arrow keys. YYYY/MM/DD HH:MM 20 1 0/01/01 00:00 Second per month + 0 sec ALM 2 3 After entering the Real-Time Clock data, press the ENTER key to save the changes. The display will indicate “Entry Accepted” and return to the initial display in step 3 and the alarm LED will be OFF. Entry accepted - MODE - DRV Rdy Auto Setpoint U5-99= 0.0PSI Initial display. U1-02= 0.00Hz LSEQ U1-91= 0.0PSI LREF <-MONITOR-> n Manual Clock Adjustment by Setting o4-17 to 1 Start-Up Programming & Operation The following actions are possible in the Clock Adjustment Mode: • Set the current time • Check the time set to the drive Real-Time Clock Table 4.2 illustrates how to set the Real-Time Clock manually. Table 4.2 Manual Clock Adjustment Procedure by Setting o4-17 to 1 Procedure 1 The “Clock Not Set” display will appear if the Real-Time Clock data is not entered within 30 seconds of power-up on a new drive. Display - MODE - 4 ALM DRV Rdy Clock Not Set Press F2 to Set FWD DATA ALM - MODE - 2 Use the up and down arrow keys to scroll through display menu until the screen shows “Programming”. Programming HELP YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide PRG FWD DATA 109 4.2 Powering Up the Drive Procedure 3 Display ALM - PRMSET - PRG Initialization Press the ENTER key to enter select the parameter setting mode. A1-00 = 0 Select Language FWD 4 Use the up and down arrow keys to scroll through display menu until parameter o4-17 appears. ALM - PRMSET - PRG Maintenance o4-17 = 0 Set time FWD ALM - PRMSET - PRG Set time 5 o4-17= 0 *0* -“0” Press the ENTER key until “0” flashes. FWD ALM - PRMSET - PRG Set time 6 o4-17= 1 *0* Set “0” Press the up arrow key so that the display changes to “1”. FWD ALM 7 Press the ENTER key and the time setting screen will appear. Use the right arrow key to select the desired digit, then set the correct date and time using the up and down arrow keys. YYYY/MM/DD HH:MM 20 1 0/01/01 00:00 Second per month + 0 sec ALM 8 After entering the correct time, press the ENTER key to save the changes. The display will return to the display shown in step 5 and the alarm LED will be OFF. Entry accepted n o4-17: Real-Time Clock Setting (Resetting RTC Back to Factory Default) No. (Addr. Hex) o4-17 (3100) Name Set/Reset Real-time Clock Description Sets the current date and time for the Real-Time Clock. 0: — — No Setting 1: Real-Time Clock Set 2: Real-Time Clock Reset Values Default: 0 Range: 0 to 2 Setting 0: — — No Setting (Default) Setting 1: Set When o4-17 is set to 1, the digital operator will show the Clock Adjustment display. In Clock Adjustment Mode the user can adjust the Real-Time Clock. Setting 2: Reset When o4-17 is set to 2, the Real-Time Clock data is cleared. A Clock Not Set alarm will occur until o4-17 is set to 1 and the Real-Time Clock is set. 110 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.3 Using the HOA Keypad 4.3 Using the HOA Keypad Use the HOA keypad to enter OFF commands, switch AUTO or HAND Mode, change parameters, and display data including fault and alarm information. u Keys and Displays ALM DIGITAL OPERATOR JVOP-183 1 11 F1 2 3 10 12 F2 M RESET AUTO 4 HAND 9 ENTER 8 M ESC 5 6 OFF 7 Figure 4.2 Keys and Displays on the HOA Keypad Display F1 Name Function Function Key (F1, F2) The functions assigned to F1 and F2 vary depending on the currently displayed menu. The name of each function appears in the lower half of the display window. ESC Key • Returns to the previous display. • Moves the cursor one space to the left. • Pressing and holding this button will return to the Frequency Reference display. RESET Key • Moves the cursor to the right. • Resets the drive to clear a fault situation. AUTO Key Selects the source of Run command and frequency reference. • Set the drive to AUTO mode. • Run command input source depends on b1-02. • Frequency reference input source depends on b1-01. 5 Up Arrow Key Scrolls up to display the next item, selects parameter numbers, and increments setting values. 6 Down Arrow Key Scrolls down to display the previous item, selects parameter numbers, and decrements setting values. OFF Key Follows the stopping method set in b1-03 to stop drive operation. 1 2 F2 ESC 3 4 7 AUTO OFF 8 9 10 11 12 ENTER Key HAND AUTO HAND HAND Key • Enters parameter values and settings. • Selects a menu item to move between displays. The drive runs at a selectable frequency reference source by b1-12. • Set the drive to HAND mode. • When b1-13 is set to 1, HAND and AUTO mode can be switched while the drive is running. AUTO Light Lit while the drive is in AUTO mode. Refer to page 113 for details. HAND Light Lit while the drive is in HAND mode. Refer to page 113 for details. ALM LED Light Refer to ALARM (ALM) LED Displays on page 113. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Start-Up Programming & Operation No. 4 111 4.3 Using the HOA Keypad u LCD Display Figure 4.3 LCD Display Table 4.3 Display and Contents No. Name Display MODE QMONI: Use F1/F2 Content Displayed when in Mode Selection. Instructions to access the Quick Monitors. MENU: Use Instructions to access the next menu item. UP/DWN 1 Operation Mode Menus 2 Mode Display Area 3 4 Ready Data Display 5 Frequency Reference Assignment <1> MONITR VERIFY PRMSET A.TUNE SETUP DRV PRG Rdy — OPR COM OP AI OFF RSEQ 6 LOCAL/REMOTE Display <2> LSEQ RREF LREF 112 Displayed when in Monitor Mode. Indicates the Verify Menu. Displayed when in Parameter Setting Mode. Displayed during Auto-Tuning. Displayed when in Setup Mode. Displayed when in Drive Mode. Displayed when in Programming Mode. Indicates the drive is ready to run. Displays specific data and operation data. Displayed when the frequency reference is assigned to the HOA keypad. Displayed when the frequency reference is assigned to the MEMOBUS/Modbus Communication Inputs of the drive. Displayed when the frequency reference is assigned to option card connected to the drive. Displayed when the function reference is assigned to an analog input. Displayed when HAND mode is OFF. Displayed when the Run command is supplied from a remote source. Note: This display will blink when b1-02 is set to 1 (Digital Inputs). Displayed when the Run command is supplied from the HOA keypad. Displayed when the Run command is supplied from a remote source. Note: This display will blink when b1-01 is set to 1 (Analog Inputs). Displayed when the Run command is supplied from the HOA keypad. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.3 Using the HOA Keypad No. 7 Name Display <MONITOR- Pressing > Function Key 2 (F2) Content F2 displays the next Quick Monitor. DATA Pressing F2 scrolls to the next display. → Pressing F2 scrolls the cursor to the right. RESET Pressing F2 resets the existing drive fault error. Pressing F2 switches Monitor mode. Monitor FWD Indicates forward motor operation. REV Indicates reverse motor operation. <MONITOR- Pressing F1 displays the next Quick Monitor. > 8 FWD/REV 9 Function Key 1 (F1) ← Pressing F1 scrolls the cursor to the left. Home Pressing F1 returns to the top menu (Frequency Reference). ESC Pressing F1 returns to the previous display. Pressing F1 switches Monitor mode. Monitor <1> Displayed when in Frequency Reference Mode. <2> Displayed when in Frequency Reference Mode and Monitor Mode. u ALARM (ALM) LED Displays Table 4.4 ALARM (ALM) LED Status and Contents State Illuminated Flashing Off Content Display When the drive detects an alarm or error. • When an alarm occurs. • When an oPE is detected. • When a fault or error occurs during Auto-Tuning. Normal operation (no fault or alarm). Start-Up Programming & Operation u AUTO LED and HAND LED Indications Table 4.5 AUTO LED and HAND LED Indications AUTO LED AUTO Off AUTO Off AUTO Off AUTO On solid AUTO Long blink (50% duty) HAND LED HAND Off HAND State OFF mode 4 HAND mode On solid HAND HAND mode when the Frequency Reference is 0 and/or decelerating in HAND mode. Long blink (50% duty) HAND Off HAND Off Running in AUTO mode Running in AUTO mode when the Frequency Reference is 0 and/or decelerating in AUTO mode. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 113 4.3 Using the HOA Keypad AUTO LED HAND LED AUTO State AUTO mode, Ready, No run command input. HAND Off Short blink (15% duty) AUTO AUTO mode, stopped by a Fast- Stop from a Multi-Function Digital Input. HAND Off Double blink 1s ON ON Flashing Flashing quickly ON ON ON ON Figure 4.4 AUTO LED and OFF LED Status and Meaning 2s 1s ON ON ON Long blink (50% dut y) ON ON ON ON ON ON Double blin k ON ON Short lin k (15% dut y) Figure 4.5 LEDs and Drive Operation in AUTO Mode Output Frequency AUTO Mode Selection HAND Mode Selection RUN Command ON OFF 6 Hz 0 Hz Frequency AUTO LED HAND LED OFF Operation Mode OFF Short blink ON Blink OFF Blink OFF OFF AUTO Figure 4.6 LEDs and Drive Operation in HAND Mode 114 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.3 Using the HOA Keypad u Menu Structure for HOA Keypad Drive Mode <2> F1 QMONI: Use F1/F2 MENU: Use UP/DWN <1> - MODE - DRV Rdy Auto Setpoint U5-99= 0.0PSI QMONI: Use F1/F2 MENU: Use UP/DWN - MODE - DRV Rdy ANF Timer U1-99= 0.0sec U1-02= 0.00Hz LSEQ U1-91= 0.0PSI LREF <-MONITOR-> U1-02= 0.00Hz LSEQ U1-91= 0.0PSI LREF <-MONITOR-> -MONITR- DRV Rdy Frequency Ref U1-01=0.00Hz - MODE - DRV Rdy Monitor Menu U1-01= 0.00Hz -MONITR- DRV Rdy Monitor U1 -01= 0.00Hz Programming Mode <3> U1-02= 0.00Hz LSEQ U1-91= 0.0PSI LREF Home JOG FWD - MODE PRG Modified Consts Modified X Parameters Home FWD - MODE PRG Pump Quick Setup U1-02= 0.00Hz LSEQ U1-91= 0.0PSI LREF Home FWD JOG <5> -MONITR- DRV Rdy Fault Trace U2 -01= ----- U1-02= 0.00Hz LSEQ U1-91= 0.0PSI LREF Home FWD -MONITR- DRV Rdy Output Freq U1-02= 0.00Hz <4> U1-02= 0.00Hz LSEQ U1-91= 0.0PSI LREF Home FWD U2-02= oPr LSEQ U2-03= 0.00Hz LREF Home FWD JOG Home FWD Initial Display <6> - MODE PRG Programming iQPump Home FWD YASKAWA XXXV, XXXHP XXXA <XXXXXXXXX> CIMR-PWXXXXXXXX <7> Start-Up Programming & Operation - MODE - PRG Auto-Tuning AUTO Home FWD Figure 4.7 HOA Keypad Menu and Screen Structure <1> The display cycles between these three displays on the initial startup screen and the Quick Monitor screens. <2> AUTO Pressing or HAND will start the motor. <3> Drive cannot operate motor. <4> Flashing characters are shown with white letters on gray background. (Example: 0 ) <5> “X” characters are used as examples in this manual. The HOA keypad will display the actual setting values. <6> The Frequency Reference appears after the initial display that shows the product name. <7> The information that appears on the display will vary depending on the drive model. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4 115 4.3 Using the HOA Keypad u Changing Parameter Settings or Values This example explains changing C1-02 (Deceleration Time 1) from 10.0 seconds (default) to 20.0 seconds. Note: During serial communication writing, if a parameter change is also attempted via the HOA keypad, a “BUSY - WRITE PROTECTED” message will display. Parameter change will not be possible from the HOA keypad until an Enter command is received via the serial communication to finish the serial writing process. Step Display/Result - MODE - DRV Rdy Auto Setpoint U5-99= 0.0PSI 1. Turn on the power to the drive. The initial display appears. U1-02= 0.00Hz LSEQ U1-91= 0.0PSI LREF <-MONITOR-> - MODE PRG Programming 2. Press or until the Parameter Setting Mode screen appears. Home FWD -PRMSET- PRG Initialization 3. Press A1-00= 0 Select Language to enter the parameter menu tree. Home FWD -PRMSET- PRG Basic Setup 4. Press or C1-01= 20.0 sec Accel Time 1 to select the C parameter group. Home FWD 5. Press two times. -PRMSET- PRG Accel/Decel -PRMSETPRG Accel Time 1 C1-01= 20.0 sec Accel Time 1 C1-01= 20.0Sec (0.0~6000.0) “20.0 sec” Home FWD Home FWD -PRMSETPRG Decel Time 1 6. Press or C1-02= 10.0Sec (0.0~6000.0) “10.0 sec” Home FWD to select parameter C1-02. -PRMSETPRG Decel Time 1 7. Press to view the current setting value (10.0 s). The leftmost digit flashes. C1-02= 0010.0Sec (0.0~6000.0) “10.0 sec” Home FWD PRG -PRMSETDecel Time 1 8. Press F2 or until the desired number is selected. “1” flashes. C1-02=0010.0Sec (0.0~6000.0) “10.0 sec” Home FWD -PRMSETPRG Decel Time 1 9. Press 10. Press and enter 0020.0. to confirm the change. C1-02=0020.0sec (0.0~6000.0) “10.0 sec” Home FWD Entry Accepted -PRMSETPRG Decel Time 1 11. The display automatically returns to the screen shown in Step 6. 116 C1-02= 20.0sec (0.0~6000.0) “10.0 sec” Home FWD YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.3 Using the HOA Keypad Step - MODE - DRV Rdy Auto Setpoint U5-99= 0.0PSI as many times as necessary to return to the initial display. U1-02= 0.00Hz LSEQ U1-91= 0.0PSI LREF <-MONITOR-> Start-Up Programming & Operation 12. Press Display/Result 4 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 117 4.4 Pump Application Presets 4.4 Pump Application Presets The following sections list the parameters affected by the different Application Presets. Note: Setting A1-03 to 6011 (VTC Pressure Control) changes the Quick Start and Pre-set parameters (tables below) and also changes HAND Mode so that it is no longer lower-limited by the minimum pump frequency or the thrust frequency. Also, the default for P1-06 when in RPM mode is 1800 RPM instead of 2400 RPM. u Parameters Set Depending on A1-03 Setting The following table shows the parameters that are set depending on the A1-03 initialization: A1-03 = 6008 (A1-06 = 8) Pressure Control Parameter 118 Value A1-03 = 6009 (A1-06 = 9) Pump Down Level A1-03 = 6010 (A1-06 = 10) Geothermal Mode Parameter Value Parameter Value b5-09 1 b1-01 5 b5-39 2 b5-01 0 P1-02 6 H3-10 21 P2-01 2 o1-08 180 P2-23 0.00% A1-03 = 6011 (A1-06 = 11) VTC Pressure Ctl Parameter A1-03 = 7770 (A1-06 = 1) General Purpose Value Parameter Value b5-03 5.0 b1-01 1 C1-01 15.0 sec b1-02 1 C1-02 15.0 sec b5-01 0 E2-04 4 C1-01 25.0 sec L5-01 0 C1-02 25.0 sec P1-03 100.0 PSI H1-06 4 P1-06 35.0 Hz H1-07 F P2-03 15sec H2-01 0 A P2-23 0.00% H2-02 P3-50 35.0 Hz H3-10 2 P3-60 35.0 Hz L5-01 0 P3-70 35.0 Hz L5-04 180.0 sec P4-12 0.0 Hz o1-06 0 P5-02 6.0 Hz P1-05 0 sec Q5-03 40.0 PSI P1-06 0.0 Hz Q5-06 50.0 PSI P4-12 0.0 Hz Q5-09 20.0 PSI P4-17 0.0 min Q5-10 5.0 min P5-02 0.0 Hz Q5-11 2 Q5-16 1.00 Q5-17 3.0 sec H2-01 80H H2-02 81H H2-03 82H YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.4 Pump Application Presets u Parameters Displayed Depending on A1-06 Setting The following table shows which parameters are shown on the Pump Quick Setting menu depending on the A1-06 selection: A1-03 = 6008 (A1-06 = 8) Pressure Control A1-03 = 6009 (A1-06 = 9) Pump Down Level A1-03 = 6010 (A1-06 = 10) Geothermal Mode A1-03 = 6011 (A1-06 = 11) VTC Pressure Ctl A1-03 = 7770 (A1-06 = 1) General Purpose E2-01 E2-04 E2-01 b1-02 E2-01 b1-01 E2-04 E2-01 E2-04 P1-03 b1-02 P1-02 E2-04 b1-02 C1-01 P1-03 P1-06 C1-01 C1-02 P1-04 Q1-01 Q2-01 C1-02 E2-01 P1-06 P1-04 Q2-02 P1-03 E2-04 P4-10 P1-06 Q2-03 Q1-01 L5-01 P5-04 P2-02 Q2-04 P1-04 L5-04 P4-10 Q2-05 P1-06 P1-06 P5-04 Q2-06 P1-08 Q2-07 P1-09 Q2-08 P1-11 Q2-09 P1-12 Q2-10 P2-02 Q2-11 P2-03 Q2-12 P4-01 P4-10 P4-02 P5-04 P4-03 Start-Up Programming & Operation Q1-01 4 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 119 4.5 iQpump Presets and Functions 4.5 iQpump Presets and Functions u iQpump Presets n Pump Down Level Control Application Preset This preset allows the drive to regulate the depth of water in a tank or other vessel that is being filled by an external source. A feedback device that measures water depth is wired to the drive. A PI-control process loop will then modulate the pump speed to pump water out the tank to keep the water depth the setpoint level (pump out at the recharge rate). The drive controller has an application preset to simplify the start up and control of this application. • System units are in feet (P1-02 = 6). • Feedback device scaling (P1-03). The feedback device scaling must be entered into the drive for proper control. • Minimum pump speed (P1-06). Most pumps cannot be run below a certain speed or cavitation can occur. • Number of Motor Poles (E2-02). The default is for a 2-pole motor. • Sleep Function. The drive controller will sleep when the system demand is low and awaken when demand returns. Required Control Wiring Most depth level transducers have current-based feedback (4-20 mA). The A2 terminal of the drive is preset for 4-20 mA and pre-programmed for PI feedback (H3-10 = B). If the sensor is voltage based (0-10 V) and terminal A3 is unused, then wire the transducer to terminal A3 and program H3-10 to F (A2 not used) and H3-06 to B (A3 PI Feedback). Start Up Procedure 1. Set parameter A1-03 to 6009 (Pump Down Level) to pre-set parameter values for this application. 2. Set the motor-rated current in parameter E2-01. This information can be found on the motor nameplate or specification sheet. 3. Set the number of motor poles in parameter E2-04 (2-pole motors have a rated RPM of slightly less than 3600 RPM; 4-pole motors have a rated RPM of slightly less than 1800 RPM). This information can be found on the motor nameplate or specification sheet. 4. Set the feedback device scaling in parameter P1-03. Check the sensor nameplate or specification sheet. For example, if the device outputs 20 mA at 14.50 ft of water depth, the set P1-03 to 14.50. The drive controller will automatically scale all associated parameters and monitors. Monitor U1-91 (Pump Feedback) will display the measured water depth in feet. The drive has a High Feedback Fault set in parameter P1-11. Make sure that P1-11 is appropriately set for sensor scaling in P1-03. 5. Set the desired water depth level in parameter Q1-01 (PI setpoint). This is desired water depth that the drive will regulate the pump speed around. To quickly access this parameter, press the HOME key and then the ENTER key. The U1-99 monitor on the home screen displays the Q1-01 PI setpoint. 6. Set the minimum speed that the pump can be run in parameter P1-06. The default is 40 Hz. This information can be found on the pump specification sheet. 7. The default settings will allow the drive to automatically restart after power loss if the drive was running at the time of power loss. To disable, set P4-10 to 1. 8. Press the AUTO key to start the drive with PI control (water depth control). Press the OFF key to stop the drive. 9. The pump can be run in a Hand (local) mode for maintenance purposes by pressing the HAND key while the drive is stopped. The HAND key acts as a start button. Press the OFF button to stop the drive. Press AUTO to return the drive to PI control. The HAND speed reference can be set in P5-02 (Hand Reference 1). Disable the HAND key by setting P5-04 to 0 (disabled). 10.Configure the sleep function. The pump can be programmed to shut off or “sleep” if the water falls below the depth set in parameter P2-02 (Sleep Level). The controller will monitor the water depth feedback signal and wake up when the water depth rises above the setting in parameter P1-04 (Start – Draw Down Level). Logically, set the Sleep Level (P2-02) lower than the PI setpoint and set the Draw Down Level (P1-04) slightly above the PI setpoint. This way the drive won’t wake up until the water has already exceeded the desired depth setting. By sleeping, the drive will save energy and mechanical wear. A setting of zero in P1-04 will disable the sleep function (default setting). 120 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions Related Parameters No. Parameter Name Access Level Selection A1-03 Initialize Parameters E2-01 Motor Rated Current E2-04 Number of Motor Poles P1-03 Feedback Device Scaling P1-11 High Feedback Level P1-06 Minimum Pump Speed P1-04 Start / Draw Down Level P2-02 Sleep Level P4-10 AUTO Mode Operator Run Power Down Storage P5-02 HAND Speed Reference 1 P5-04 HAND Key Function Selection Q1-01 PID Controller Setpoint 1 U1-99 Anti-No-Flow Timer Start-Up Programming & Operation A1-01 Setting Values Default: 2 Range: 0 to 3 Default: 0 Range: 0 to 5550; 6008 to 6011; 7770 Default: Min.: 10% of drive rated current Max.: 200% of drive rated current Default: 2 Min.: 2 Max.: 48 Default: 145.0 PSI Min.: 0.1 Max.: 6000.0 Default: 0.0 PSI Min.: 0.0 Max.: 6000.0 Default: 40.0 Hz Min.: 0.0 Max.: [E1-04] Default: 0.0 Min.: -999.9 Max.: 999.9 Default: 0.0 Hz Min.: 0.0 Max.: 6000.0 Default: 0 Range: 0, 1 Default: 40.0 Hz Min.: 0 Max.: [E1-04] Default: 1 Range: 0, 1 Default: 0.0 Min.: 0.0 Max.: 6000.0 No signal output available 4 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 121 4.5 iQpump Presets and Functions n Geothermal Mode Application Preset A geothermal well facilitates heat transfer between the earth and a known system, such as space heating, dehydration, electric power generation and food processing. The geothermal function has the ability to regulate the speed of the drive controller based on an external temperature signal following a preset temperature-speed curve. The drive controller has an application preset to simplify the start up and control of this application Required Control Wiring Most temperature transducers have current-based feedback, (4 - 20 mA). The A2 terminal of the drive is pre-set for 4 to 20 mA and Temperature Feedback (H3-10 = 21). If the sensor is voltage-based (0 to 10 V) and terminal A3 is unused, then wire the transducer to terminal A3 and program H3-10 to F (A2 not used) and H3-06 to 21 (A3 Temperature Feedback). Start Up Procedure 1. Set parameter A1-03 to 6010 (Geothermal Mode) to pre-set parameter values for this application. The second line of the HOA Keypad will read “Geothermal Mode”. 2. Set the method of giving the drive a run command in parameter b1-02. The default setting is to use the AUTO key on the HOA keypad. 3. Set the motor-rated current in parameter E2-01. This information can be found on the motor nameplate or specification sheet. 4. Set the number of motor poles in parameter E2-04 (2-pole motors have a rated RPM of slightly less than 3600 RPM; 4-pole motors have a rated RPM of slightly less than 1800 RPM). This information can be found on the motor nameplate or specification sheet. 5. Set the minimum speed at which the pump can run in parameter P1-06. The default is 40 Hz. This information can be found on the pump specification sheet. 6. Set the feedback device scaling in parameters Q2-01 and Q2-02. Q2-01 sets the temperature at 0 V (4 mA). Q2-02 sets the temperature at 10 V (20 mA). The monitor for this feedback is U1-80 (Geothermal Temperature). 7. Set the pump speed-temperature characteristics in Q2-03 to Q2-08. This allows the drive to modulate the pump speed based on the analog input temperature feedback of the water. This will attempt to regulate the water temperature between the Q2-06 and Q2-07 settings. Figure 4.8 shows normal operation. 122 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions Max Geothrm Speed (Q2-04) Frequency Reference (Hz) Min Geothrm Speed (Q2-03) Low Temp @ Max (Q2-05) Low Temp @ Min (Q2-06) High Temp @ Min (Q2-07) High Temp @ Max (Q2-08) Temperature ( ºF ) Figure 4.8 Normal Temperature Regulation The drive can also be programmed for inverse operation by changing the parameter settings in Q2-03 to Q2-08 as shown in Figure 4.9. Max Geothrm Speed (Q2-04) Frequency Reference (Hz) Min Geothrm Speed (Q2-03) Low Temp @ Min (Q2-06) High Temp @ Min (Q2-07) High Temp @ Max (Q2-08) Temperature ( ºF ) Figure 4.9 Inverse Temperature Regulation 8. Set the response to temperature feedback signal loss. The drive will monitor the feedback signal for signal loss. This function can be disabled by setting Q2-09 to 0. When a wire break is detected (or if no analog input is programmed for Geothermal Temp), a “TLGI - Geothermal Input” fault or “Temp Lost – Geothermal Input” alarm will be triggered depending on the setting of Q2-09. If Q2-09 is set to 2 (fault), the drive will only fault when running in AUTO Mode. It will only display the alarm if not running or if it is running in HAND Mode. 9. Set the Geothermal Sleep characteristics. The drive will sleep if the drive runs at the minimum speed (Q2-03) for the time set in Q2-10. Setting Q2-11 to 0 disables the sleep function (default setting). 10.Set the wake up characteristics. The drive will wake from Geothermal Sleep when Geothermal Temperature (U1-80) is greater than the “High Temp @ Min” plus the Geothermal Wake Level (Q2-07 + Q2-11) or is less than “Low Temp @ Min” minus the Geothermal Wake Level (Q2-06 – Q2-11) for more than the Geothermal Wake Delay Time (Q2-12). 11.The default settings will allow the drive to automatically restart after power loss if the drive was running at the time of power loss. Set P4-10 to 1 to disable this function. 12.Press the AUTO key to start the drive with PI control (water depth control). Press the OFF key to stop the drive. 13.The pump can be run in HAND (LOCAL) Mode for maintenance purposes by pressing the HAND key while the drive is stopped. The HAND key acts as a start button. Press the OFF button to stop the drive. Press AUTO to return the drive to geothermal control. The HAND speed reference can be set in P5-02 (Hand Reference 1). Disable the HAND key by setting P5-04 to 0 (disabled). YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 123 Start-Up Programming & Operation Low Temp @ Max (Q2-05) 4 4.5 iQpump Presets and Functions Related Parameters, Faults, and Alarms No. 124 Parameter Name A1-01 Access Level Selection A1-03 Initialize Parameters b1-02 Run Command Selection 1 E2-01 Motor Rated Current E2-04 Number of Motor Poles P1-03 Feedback Device Scaling P1-04 Start / Draw Down Level P1-06 Minimum Pump Speed P1-11 High Feedback Level P2-02 Sleep Level P4-10 AUTO Mode Operator Run Power Down Storage P5-02 HAND Speed Reference 1 P5-04 HAND Key Function Selection Q1-01 PID Controller Setpoint 1 Q2-01 Minimum Geothermal Temperature Input Q2-02 Maximum Geothermal Temperature Input Q2-03 Minimum Geothermal Speed Q2-04 Maximum Geothermal Speed Q2-05 Low Temperature to Run at Maximum Geothermal Speed Q2-06 Low Temperature to Run at Minimum Geothermal Speed Setting Values Default: 2 Range: 0 to 3 Default: 0 Range: 0 to 5550; 6008 to 6011; 7770 Default: 0 Range: 0 to 3 Default: Min.: 10% of drive rated current Max.: 200% of drive rated current Default: 2 Min.: 2 Max.: 48 Default: 145.0 PSI Min.: 0.1 Max.: 6000.0 Default: 0.0 Min.: -999.9 Max.: 999.9 Default: 40.0 Hz Min.: 0.0 Max.: [E1-04] Default: 0.0 PSI Min.: 0.0 Max.: 6000.0 Default: 0.0 Hz Min.: 0.0 Max.: 6000.0 Default: 0 Range: 0, 1 Default: 40.0 Hz Min.: 0 Max.: [E1-04] Default: 1 Range: 0, 1 Default: 0.0 Min.: 0.0 Max.: 6000.0 Default: 0.0 °F Min.: -110.0 Max.: 275.0 Default: 120.0 °F Min.: -100.0 Max.: 275.0 Default: 40.0 Hz Min.: 0.0 Max.: 400.0 Default: 60.0 Hz Min.: 0.0 Max.: 400.0 Default: 55.0 °F Min.: -110.0 Max.: 275.0 Default: 65.0 °F Min.: -110.0 Max.: 275.0 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions No. Parameter Name Q2-07 High Temperature to Run at Minimum Geothermal Speed Q2-08 High Temperature to Run at Maximum Geothermal Speed Q2-09 Geothermal Temperature Loss Detection Q2-10 Geothermal Sleep Delay Time Q2-11 Geothermal Temperature Delta Wake Level U1-99 Anti-No-Flow Timer Setting Values Default: 75.0 °F Min.: -110.0 Max.: 275.0 Default: 85.0 °F Min.: -110.0 Max.: 275.0 Default: 1 Range: 0 to 2 Default: 30 s Min.: 0 Max.: 3600 Default: 0.0 °F Min.: 0.0 Max.: 50.00 No signal output available H3 Multi-Function Analog Input Settings H3-oo Setting Function Description 21 Geothermal Temperature Full scale: Q2-02 = 10 V (or 20 mA), Q2-01 = 0 V (or 4 mA) This input is internally limited to -999.9 °F to +999.9 °F F Not Used Disables the functionality of the programmed terminal. HOA Keypad Display Error Name oPE29 Geothermal Set Error Cause Possible Solutions P1-01 parameter selection is not compatible Confirm b1-01 and P1-01 parameter settings. with Geothermal Mode (b1-01 = 5). HOA Keypad Display TLGI Geothermal Input Fault Name Temperature Lost Geothermal Input The geothermal input is not present. The drive was running while b1-01 = 5, H3-0o≠ 21 (Geothermal Temp), and Q2-09 = 2 (Fault). HOA Keypad Display Geo Params Chk Q2-05 to Q2-08 Cause The temperature parameter values are set incorrectly. Start-Up Programming & Operation Cause Possible Solutions The input signal level has dropped below 3 mA or risen above 21 mA when the drive was running and b1-01 = 5, H3-0o = 21 Confirm that the device connected to the analog input terminal is installed and working properly. (Geothermal Input), H3-0o = 2 (4 to 20 mA), and Q2-09 = 2 (Fault). Assign one of the analog inputs to “Geothermal Temperature”, H3-0o = 21. Minor Fault Name Geothermal Mode Parameters The drive is running at the level set in Q2-03 due to an incorrect setting. Possible Solution Set the temperature parameters in the following order: Q2-08 > Q2-07 > Q2-06 > Q2-05 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4 125 4.5 iQpump Presets and Functions G eo the rm al S lee p Lo w T em pe rature O pe ration A uto R un C omm an d W ak e Le v el ( Q 2- 06 – Q 2- 11 ) Q 2 -06 Lo w T em p @ M in Q 2 -07 H igh T em p @ M in W ak e Le v el (Q 2- 07 + Q 2- 11 ) G eo the rm al T em p ( H 3-0 x = 21) ( U 1 -80 ) Q 2-10 G eo thrm S lp D ly Q 2-12 G eo thrm W ak e D ly Q 2- 04 M ax G eo the rm S pee d Q 2- 03 M in G eo the rm S pee d O utpu t F requen c y “S leep A c tiv e – W ait F or S tart” M ess age “S tart D elay – T im er A c tiv e” M ess ag e G eo the rm al E nab led (b 1-01 = 5 ), G eo the rm al S leep E nab led (Q 2 -11 > 0 .0 ) Figure 4.10 Geothermal Sleep – Low Temperature Operation G eo the rm al S lee p H igh T em pe rature O pe ration A uto R un C omm an d W ak e Le v el ( Q 2- 06 – Q 2- 11 ) Q 2 -06 Lo w T em p @ M in Q 2 -07 H igh T em p @ M in W ak e Le v el (Q 2- 07 + Q 2- 11 ) G eo the rm al T em p ( H 3-0 x = 21) ( U 1 -80 ) Q 2-10 G eo thrm S lp D ly Q 2-12 G eo thrm W ak e D ly Q 2- 04 M ax G eo the rm S pee d Q 2- 03 M in G eo the rm S pee d O utpu t F requen c y “S leep A c tiv e – W ait F or S tart” M ess age “S tart D elay – T im er A c tiv e” M ess ag e G eo the rm al E nab led (b 1-01 = 5 ), G eo the rm al S leep E nab led (Q 2 -11 > 0 .0 ) Figure 4.11 Geothermal Sleep – High Temperature Operation 126 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions G eo the rm al S lee p H igh and Lo w T em pe rature O pe ration A uto R un C omm an d W ak e Le v el ( Q 2- 06 – Q 2- 11 ) Q 2 -06 Lo w T em p @ M in Q 2 -07 H igh T em p @ M in W ak e Le v el (Q 2- 07 + Q 2- 11 ) G eo the rm al T em p ( H 3-0 x = 21) ( U 1 -80 ) Q 2-10 G eo thrm S lp D ly Q 2-12 G eo thrm W ak e D ly Q 2- 04 M ax G eo the rm S pee d Q 2- 03 M in G eo the rm S pee d O utpu t F requen c y “S leep A c tiv e – W ait F or S tart” M ess age “S tart D elay – T im er A c tiv e” M ess ag e G eo the rm al E nab led (b 1-01 = 5 ), G eo the rm al S leep E nab led (Q 2 -11 > 0 .0 ) Figure 4.12 Geothermal Sleep – High and Low Temperature Operation n General Purpose Mode Application Preset The purpose of this mode is to allow the drive controller to run a motor at a set speed without the PI process loop. This preset is designed to simplify using the drive for applications other than pumping control. The default settings call for the frequency reference to be an analog input and the run command to come from the terminal strip via a maintain contact closure. The PI loop is disabled and no process feedback is required. Required Control Wiring Start Up Procedure 1. Set parameter A1-03 to 7770 (General Purpose Mode) to pre-set parameter values for this application. 2. Set the source of the frequency reference for the drive controller in parameter b1-01. The default setting is from the terminal strip via a 0 to 10 V analog signal wired into terminal A1. 3. Set the source of the Run Command for the drive controller in parameter b1-02. The default setting is from the terminal strip via a maintained contact closure. 4. Set the Acceleration Time of the motor in parameter C1-01. This is the time to accelerate the motor from zero speed to 60 Hz (E1-04 Maximum Output Frequency). 5. Determine the stopping method of the motor. The default setting is coast to stop. To ramp the motor to a stop, set b1-03 to 0 and then set the motor deceleration time in parameter C1-02. This is the time to stop the motor from to 60 Hz (E1-04 Maximum Output Frequency) to zero speed. 6. Set the motor-rated current in parameter E2-01. This information can be found on the motor nameplate or specification sheet. 7. Set the number of motor poles in parameter E2-04 (2-pole motors have a rated RPM of slightly less than 3600 RPM; 4-pole motors have a rated RPM of slightly less than 1800 RPM). This information can be found on the motor nameplate or specification sheet. 8. Determine whether the drive controller should attempt to reset itself after a fault. The default setting is disabled. The function is turned on by setting 1 to 10 reset attempts in parameter L5-01 and the time between each reset in parameter L5-04. 9. Set the minimum speed at which the motor can run in parameter P1-06. The default is 0 Hz. If the system has a minimum safe operation speed, set it in P1-06. This will act as a lower limit of the frequency reference. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 127 Start-Up Programming & Operation No additional control wiring is required when the drive controller is at its default settings. 4 4.5 iQpump Presets and Functions 10.The motor can be run in HAND (LOCAL) Mode for maintenance purposes by pressing the HAND key while the drive is stopped. The HAND key acts as a start button. Press the OFF button to stop the drive. Set P5-04 to 0 to disable the HAND key. The default frequency reference is 0.0 Hz in HAND Mode. This can be changed in parameter P5-02. The AUTO key has no effect with the default settings in the General Purpose Application Preset. Related Parameters No. Parameter Name A1-03 Initialize Parameters b1-01 Frequency Reference Selection 1 b1-02 Run Command Selection 1 b1-03 Stopping Method Selection C1-01 Acceleration Time 1 C1-02 Deceleration Time 1 E1-04 Maximum Output Frequency E2-01 Motor Rated Current E2-04 Number of Motor Poles L5-01 Number of Auto Restart Attempts L5-04 Fault Reset Interval Time P1-06 Minimum Pump Speed P5-02 HAND Reference P5-04 HAND Key Function Selection Setting Values Default: 0 Range: 0 to 5550; 6008 to 6011; 7770 Default: 0 Range: 0 to 5 Default: 0 Range: 0 to 3 Default: 1 Range: 0 to 3 Default: 20.0 s Min.: 0.0 Max.: 6000.0 Default: 20.0 s Min.: 0.0 Max.: 6000.0 Default: 60.0 Hz Min.: 40.0 Max.: 400.0 Default: Min.: 10% of drive rated current Max.: 200% of drive rated current Default: 2 Min.: 2 Max.: 48 Default: 5 Min.: 0 Max.: 10 Default: 20.0 s Min.: 10.0 Max.: 3600.0 Default: 40.0 Hz Min.: 0.0 Max.: [E1-04] Default: 40.0 Hz Min.: 0 Max.: [E1-04] Default: 1 Range: 0, 1 n Well Draw Down Control Application Preset The Well draw down function allows the drive to deliver water at a constant pressure as long as ground water level remains above a specified level. If the ground water level drops to this specified level the drive will switch from a constant pressure regulator to a level regulator, which will continue to supply water at the recharge rate of the well. Water will continue to flow at a reduced rate. Should the water level down hole continue to drop the drive will go to sleep and wait till the water level rises again to the specified wake up level to start pumping again. Once the water level rises above that level it will switch back to constant pressure mode. Start Up Procedure The following is a sample setup for the Well Draw Down function with 4 to 20 mA transducer feedback on both level (connected to input A1) and constant pressure (connected to A2) 1. 128 Select a Proper Depth Sensing Transducer. The proper transducer for depth sensing has been specifically designed for depth sensing. This means the transducer element, electrical connections, and connecting cable are sealed for submersion. Additionally the sensor will have a vent tube running the length of the electrical conductors to compensate for changes in barometric air pressure, which ensures accurate feedback with changing weather patterns. Another YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions important design characteristic is that the electrical conductors are installed by the manufacturer at the length specified by the installer. This ensures that the manufacturer can calibrate the transducer to compensate for the voltage drop across the conductor length. The maximum length for pressure transducer leads is 50 meters (164 feet) and beyond that length the voltage drop will cause inaccurate feedback. It is common for wells to exceed this depth. Do not use standard pressure transducer for level control. Select a range of depth that closely matches your application range. One size does not fit all as depth calculations work with small changes in feedback. If the range is too large accuracy will be compromised. Proper Depth Transducer Characteristics: Sealed element and electrical connections Barometric compensation Specified cable length calibrated by the manufacturer 2. 3. 4. Proper range, one that is close to applications actual operation Install Depth Sensing Pressure Transducer Down Hole. Since the feedback from the transducer is low voltage and the output of the drive to the motor is a PWM waveform an effort should be made to keep the transducer leads as far from the motor leads as possible. Given that space in the bore hole is at a premium this is a difficult task and connection of the transducer shield drain wire is important. Many installers will set the transducer in its own plastic tubing with a cap at the bottom end that the transducer can rest on. It is necessary to drill holes in the tubing at or close to the bottom to allow water to flood the tube. This type of installation will help protect the transducer and connecting cable from damage and allow it to be retrieved if necessary. Connect Level Transducer to the drive via Terminal A1. Most depth level transducers are current based feedback, typically 4 to 20 mA. The A1 terminal of the drive is selectable for either voltage or current based pressure transducer feedback. Most transducers in common use are current based (4 to 20 mA). Set the drive to accept current based (4 to 20 mA) Feedback Set the A1 terminal of Jumper S1 to current type input (I) as shown in Figure 4.13. Set parameter H3-01 to 2 (4 to 20 mA) for signal type on A1. Set parameter H3-02 to 23, function of the A1 input, Well Level feedback Jumper S1 V I A1 A2 A3 Figure 4.13 Terminal A1 Set to Current Input Description Voltage input (0 to 10 V Bipolar) Current input (4 to 20 mA or 0 to 20 mA) 5. Connect Standard Pressure Transducer to Terminal A2. Terminal A2 is designed to accept both current and voltage based feedback devices and by default the drive is set to 4 to 20 mA input. Make sure to set all necessary parameters for proper constant pressure regulation. 6. Set parameter Q4-01 to 1 to enable the Well Draw Down Feature. 7. Set Constant Pressure Setpoint in U1-01 or Q1-01. U1-01 is the only monitor which will change parameter values without going to the program menu. Using this monitor, the setpoint can be changed while the drive is running. A setpoint must be entered for the Well Draw Down feature to work properly. 8. Enter the maximum value of the range of the transducer in PSI in parameter Q4-02 and the drive will automatically scale associated parameters. The level transducer should display a specification for range (e.g., 0 to 50 PSI [115.4 feet]) 1 PSI = 2.308 ft. 9. Set Well Level to be maintained in parameter Q4-03 This is the level (in feet) at which the drive will stop regulating pressure and start maintaining level. If the water level rises above this level, the drive will automatically switch back to pressure regulation. 10.Set Well Level to Sleep in parameter Q4-04 When the well level reaches this level (in feet) and the sleep time set in parameter Q4-05 expires, the drive will go to sleep and stop running the pump. The pump will remain in this state until the well level reaches the wake level set in Q4-06.. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 129 Start-Up Programming & Operation Table 4.6 Jumper S1 Settings Setting V (top position) I (bottom position) 4 4.5 iQpump Presets and Functions 11.Set Wake Level in parameter Q4-06. When the well level has reached this level (in feet) and the on-delay timer set in Q4-07 expires, the drive will automatically start running again. Set this level should to a value greater than Q4-03 (Maintain Level) so the drive will automatically go to pressure regulation mode. 12.Set the Minimum Pump Speed while in Level Control in parameter Q4-08 Set this speed at a level which ensures that the pump is moving water out of the well. If it is set to a speed where no water is moving, the PI regulator may not drive the well level to the sleep level and cause damage to the pump or motor. This speed is only used in Level Control Mode but the actual minimum speed in Level Mode will be the greater value between P1-06 (minimum pump frequency) and P4-05 (thrust frequency). If Q4-08 is set higher than P1-06 and P4-05, it will only be used while the drive is in Level Control Mode. 13.Set Low Level Detection Value in Parameter Q4-09 and program the drive response in Q4-11 This is the level (in feet) at which you do not want the pump to run at because below this level there is a danger dry running. Generally this level is a fail safe level and if reached you would likely want the drive to fault out and stop running immediately. This can also activate the drive fault contacts, which can be used for auxiliary notification such as a horn or external warning light. In Q4-11 the drive can be programmed for one of four responses 0. No Response, 1. Alarm Only, 2. Fault 3. Time Delay. Default is Alarm Only. Note: option 3 is controlled by parameters Q4-12 (timer) and L5-01 > 0 (fault autorestart). 14.Verify Settings and Well Level in Monitor U1-97 By using monitor U1-97 (displayed in feet) without the pump running you should see the well level displayed and can note it down. Then press the Auto button to start the drive in pressure regulation mode. This assumes all other parameters for pressure regulation have been set up prior to this step. Once the setpoint pressure has been reached check U1-97 and note the level. Depending on the recharge rate of the well this value will be lower than the level without the pump running by some amount. This can give you an idea of the well’s recharge rate at the current demand. It will give you an idea if the other levels you have set are appropriate. The level should be checked periodically over the season of operation to check level variations related to times of the year. Related Parameters No. 130 Parameter Name H3-01 Terminal A1 Signal Level Selection H3-02 Terminal A1 Function Selection L5-01 Number of Auto Restart Attempts P1-06 Minimum Pump Speed P4-05 Pre-Charge Loss of Prime Level Q1-01 PID Controller Setpoint 1 Q4-01 Water Level Selection Q4-02 Water Level Scaling Q4-03 Water Level Setpoint Q4-04 Minimum Water Level Q4-05 Water Level Sleep Delay Time Setting Values Default: 0 Range: 0 to 3 Default: 0 Range: 0 to 32 Default: 5 Min.: 0 Max.: 10 Default: 40.0 Hz Min.: 0.0 Max.: [E1-04] Default: 0.0 A Min.: 0.0 Max.: 1000.0 Default: 0.0 Min.: 0.0 Max.: 6000.0 Default: 0 Range: 0, 1 Default: 100 PSI Min.: 5 Max.: 500 Default: 20.0 ft Min.: 0.0 Max.: 1200.0 Default: 10.0 ft Min.: 0.0 Max.: 1200.0 Default: 5 s Min.: 0 Max.: 3600 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions No. Parameter Name Q4-06 Wake-Up Water Level Q4-07 Water Level Control Sleep Wake-Up Time Q4-08 Level Control Minimum Speed Q4-09 Low Level Detection Level Q4-10 Low Level Detection Time Delay Q4-11 Low Level Behavior Q4-12 Water Level Control Auto-Restart Time Q4-15 Low Water Level Detection Time Unit U1-01 Frequency Reference U1-97 Water Level Setting Values Default: 30.0 ft Min.: 0.0 Max.: 1200.0 Default: 1 s Min.: 0 Max.: 3600 Default: 0.00 Hz Min.: 0.00 Max.: 400.00 Default: 0.0 ft Min.: 0.0 Max.: 1200.0 Default: 0.0 Min.: 0.0 Max.: 300.0 Default: 1 Range: 0 to 3 Default: 5.0 min Min.: 0.1 Max.: 6000.0 Default: 0 Range: 0, 1 10 V: Max frequency Full scale: 10 V = Q4-02 u iQpump Functions This function is used with low suction inlet pressure switches on pressure booster systems for buildings that get their main water supply from a municipality. This pressure switch enables and disables the pump system when the inlet supply is at a low demand and when running the pump system in this condition will cause damage. An inlet pressure switch is wired directly into the drive using one of the digital input terminals. If the pressure switch is active and sufficient pressure is available, the drive system will operate normally. If the pressure switch indicates that incoming pressure is too low, the drive will take the following actions: • The drive will be forced into a sleep-like state (coast to stop). • Any drives staged in multiplex mode will immediately coast to stop. • The selected alarm “Low City Pressure”, “Low Suction Pressure”, or “Low Water In Tank” will be displayed (determined by P4-24). All drives will restart when sufficient pressure returns. Required Control Wiring Any one of the multi-function digital inputs (S1 to S8) must be wired and programmed with a low suction inlet pressure switch. The appropriate terminal parameter (H1-oo) must be to set 73 (Low City Pressure). The action of the switch (normally open / normally closed) is set in parameter P4-21. Start Up Procedure 1. Set all other parameters required for the application such as PI control loop, sleep, motor, and I/O parameters. 2. Set one digital input for the low suction inlet pressure switch (H1-oo = 73). Wire the switch to this terminal. 3. Configure the terminal for a normally open / closed switch type using parameter P4-21. 4. Configure the delay times for activating and removing the alarm in parameters P4-23 and P4-24. This can be used to stop the drive from cycling too frequently if the pressure varies a lot. 5. Select the alarm message that will be displayed when a Low City condition is detected using parameter P4-24. Options include “Low Cty Pressure”, “Low Suction Pres”, and “Low Watr In Tank”. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 131 Start-Up Programming & Operation n Low City or Low Suction Inlet Pressure 4 4.5 iQpump Presets and Functions Related Parameters, Faults, and Alarms No. Parameter Name P4-21 Low City Input Select P4-22 Low City On-Delay Time P4-23 Low City Off-Delay Time P4-24 Low City Alarm Text Setting Values Default: 1 Range: 0, 1 Default: 10 s Min.: 1 Max.: 1000 Default: 5 s Min.: 0 Max.: 1000 Default: 0 Range: 0 to 2 H1 Multi-Function Digital Input Settings H1-oo Setting 73 Function Low City Press Description Indicates that sufficient or insufficient pressure is present on the inlet to the pump. Used mainly for pressure booster situations. HOA Keypad Display Low City Pressure Cause Low City Pressure Minor Fault Name HOA Keypad Display Low Suction Pressure Cause Low Suction Pressure Possible Solution • Check pressure switch contact for correct operation. Insufficient pressure is present on the inlet • Check control wiring to drive terminal strip from pressure switch contact. to the pump. • Check to make sure that suction pressure is present by means of a separate measuring device. Insufficient suction pressure is present. HOA Keypad Display Low Water in Tank Cause The water level in the tank is too low. Minor Fault Name Possible Solution • Check pressure switch contact for correct operation. • Check control wiring to drive terminal strip from pressure switch contact. • Check to make sure that suction pressure is present by means of a separate measuring device. Minor Fault Name Low Water in Tank Possible Solution • Check pressure switch contact for correct operation. • Check control wiring to drive terminal strip from pressure switch contact. • Check to make sure that suction pressure is present by means of a separate measuring device. n Hard Current Limit This function provides a current limit of the pump (motor). The function is designed to prevent long-term overload conditions of the pump, especially if the motor and drive are oversized compared to the pump. The drive will attempt to limit the output current by reducing the frequency reference. The frequency is reduced using an internal current PI regulator. This function will only operate correctly when the drive is connected to a variable torque motor load such as a centrifugal pump. More specifically, it will only operate if the load is such that output current increases as output frequency increases (and vice-versa). The current limit function reduces the pump speed to just above the lower value between the minimum pump speed (P1-06) or the minimum output frequency. If PI mode is enabled (b5-01 > 0), a special limit will be applied to the PID integrator when output current limit is active to prevent integrator wind-up. Start Up Procedure 1. Set all other parameters required for the application such as PI control loop, sleep, motor, and I/O parameters 2. Turn on the current limit function by setting Q3-01 to 1 (enabled). The default setting is 0 (disabled). 3. Set the desired current limit in Q3-02. This value should not exceed the motor, pump or drive’s ratings. This does not in any way change the motor (oL1) and inverter (oL2) overload functions. 4. If desired, program a multi-function digital output (H2-oo) to 89 (Output Current Limit) to annunciate the alarm. 132 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions Related Parameters No. Parameter Name Q3-01 Output Current Limit Select Q3-02 Current Limit Setting Values Default: 0 Range: 0, 1 Default: 0.0 A Min.: 0.0 Max.: 1000.0 H2 Multi-Function Digital Output Settings H2-oo Setting 89 Function Output 1 Limit Description Closed: Drive output speed is being limited due to the output current limit or the single phase foldback regulator. n Vertical Turbine Controller (VTC) Vertical turbine pumps are typically used when water needs to be pumped from deep-water wells or open bodies of water such as rivers, lakes, irrigation canals, lifting stations, and water storage facilities. The VTC Application Preset allows the operator to easily setup control for a wide range of pumping applications. The drive will automatically adjust pump-operating conditions from Simplex (one pump on the drive) to multiple lag pumps as the process variables change. Control can be extended from simple pressure regulation to adding suction and vacuum control as well. Required Control Wiring Start Up Procedure for iQpump1000 with Three Lag Pumps 1. Set parameter A1-03 to 6011 (VTC Pressure Control). This will preset parameter values for this application. 2. Set the motor-rated current in parameter E2-01. This information can be found on the motor nameplate or specification sheet. 3. Set the number of motor poles in parameter E2-04 (2-pole motors have a rated RPM of slightly less than 3600 RPM; 4-pole motors have a rated RPM of slightly less than 1800 RPM). This information can be found on the motor nameplate or specification sheet. 4. Set the feedback device scaling in parameter P1-03. Check the sensor nameplate or specification sheet. For example, if the device outputs 20 mA at 100.0 PSI of pressure, then set P1-03 to 100.0 PSI. The drive controller will automatically scale all associated parameters and monitors. Monitor U1-91 (Pump Feedback) will display the measured pressure in PSI. The drive has a High Feedback Fault set in parameter P1-11. Make sure that P1-11 is appropriately set for sensor scaling in P1-03. 5. Set the desired pressure setpoint in parameter Q1-01 (PI setpoint). This is desired pressure that the drive will regulate the pump to control around. To quickly access this parameter, press the HOME key and then the ENTER key. The U1-99 monitor on the home screen displays the Q1-01 PI setpoint. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 133 Start-Up Programming & Operation Most pressure transducers have current-based feedback (4 - 20 mA). The drive A2 terminal is pre-set for 4-20 mA and preprogrammed for PI feedback (H3-10 = B). If the sensor is voltage based (0-10 V) and terminal A3 is unused, then wire the transducer to terminal A3 and program H3-10 to F (A2 not used) and H3-06 to B (A3 PI Feedback). When using lag pumps, the lag pump on/off control must be wired to the drive digital output terminals. The figure below shows the drive with the pressure transducer wired into terminal A2 and 3 lag pumps wired into output relays. 4 4.5 iQpump Presets and Functions 6. Set the minimum speed that the pump can be run in parameter P1-06. The default is 35 Hz. This information can be found on the pump specification sheet. 7. The default setting is for the drive to control the pump motor wired to the drive. Additional Lag pumps can be added to the system by wiring the on/off switch of the lag-pump motor to the drive as shown in the figure above. Set parameter P1-01 to 1 (Contactor Lag). This will enable the multiplexing control for multiple pumps 8. Set the number of additional lag pumps in parameter P3-00. For example, for a system with the drive pump and 3 additional lag pumps, set P3-00 to 3. 9. Set each lag pump’s shutdown (stage off) level in Parameters P3-50, P3-60 and P3-70. The value is set in Hz. The setting tells the drive controller to de-stage the lag pump if the output frequency drops below this level. This setting needs to be coordinated with minimum pump speed (P1-06) and the sleep level. It is important that all lag pumps be de-staged above the sleep level or the drive will not enter sleep mode 10.The drive will stage lag pumps on based on the output frequency of the drive. At start, only the drive pump will be running. If the drive output frequency reaches 60 Hz for the time set in P3-05 and the pressure setpoint cannot be met, the drive will stage on (turn on) one of the lag pumps. The drive will stage on additional lag pumps until the pressure setpoint can be achieved. 11.The drive will stage lag pumps off based on the output frequency of the drive. Assume the system has been running with multiple lag pumps on. Now the demand starts to drop. The drive’s output frequency will drop. If the output frequency falls below a lag pump frequency shutdown level for the time set in P3-09, the pump is de-staged. The drive will continue to de-stage pumps until the pressure setpoint can be met 12.Configure the sleep function. The drive can be programmed to shut off or sleep if the pressure stays at or above the Q1-01 setpoint with all lag pumps de-staged and the drive running at the minimum pump speed. In order to turn on the sleep function, set parameter P1-04 (Start – Draw Down Level) to a level slightly less than the pressure Q1-01 setpoint. When the drive is sleeping and the system pressure drops below the P1-04 setting, the drive will wake up and begin regulating pressure again. By sleeping, the drive will save energy and mechanical wear. A setting of zero in P1-04 will disable the sleep function (default setting). 13.Press the AUTO key to start the drive with PI control (pressure control). Press the OFF key to stop the drive 14.The pump can be run in a Hand (local) mode for maintenance purposes by pressing the HAND key while the drive is stopped. The HAND key acts as a start button. Press the OFF button to stop the drive. Press AUTO to return the drive to PI control. The HAND frequency reference is preset to 6 Hz in parameter P5-02. Disable the HAND key by setting P5-04 = 0 (disabled). Related Parameters No. 134 Parameter Name A1-03 Initialize Parameters E2-01 Motor Rated Current E2-04 Number of Motor Poles H3-06 Terminal A3 Function Selection H3-10 Terminal A2 Function Selection P1-01 Pump Mode P1-03 Feedback Device Scaling P1-04 Start / Draw Down Level P1-06 Minimum Pump Speed Setting Values Default: 0 Range: 0 to 5550; 6008 to 6011; 7770 Default: Min.: 10% of drive rated current Max.: 200% of drive rated current Default: 2 Min.: 2 Max.: 48 Default: 20 Range: 0 to 32 Default: B Range: 0 to 32 Default: 0 Range: 0, 1, 3 Default: 145.0 PSI Min.: 0.1 Max.: 6000.0 Default: 0.0 Min.: -999.9 Max.: 999.9 Default: 40.0 Hz Min.: 0.0 Max.: [E1-04] YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions No. Parameter Name P1-11 High Feedback Level P3-00 Number of Lag Pumps P3-05 Add Pump Delay Time P3-09 Shutdown Pump Delay Time P3-50 Pump 2 Frequency Shutdown Level P3-60 Pump 3 Frequency Shutdown Level P3-70 Pump 4 Frequency Shutdown Level P5-02 HAND Reference P5-04 HAND Key Function Selection Q1-01 PID Controller Setpoint 1 U1-91) U1-99 Pump Feedback Anti-No-Flow Timer Setting Values Default: 0.0 PSI Min.: 0.0 Max.: 6000.0 Default: 1 Min.: 1 Max.: 5 Default: 2 s Min.: 0 Max.: 3600 Default: 5 s Min.: 0 Max.: 3600 Default: 40.0 Hz Min.: 0.0 Max.: 400.0 Default: 40.0 Hz Min.: 0.0 Max.: 400.0 Default: 40.0 Hz Min.: 0.0 Max.: 400.0 Default: 40.0 Hz Min.: 0 Max.: [E1-04] Default: 1 Range: 0, 1 Default: 0.0 Min.: 0.0 Max.: 6000.0 No signal output available No signal output available The pre-change function is designed to start a pumping system in a controlled manner. Rather than turning on the PI loop immediately at start up, the pre-charge function operates at a fixed speed to pre-fill the piping or storage tank before switching to PID control. This prevents the PI loop integrator from building up unnecessarily and also allows for a soft pressurization and fill of the system. When an “auto” run command is issued or when waking up from the sleep state, the drive will check to see if it should perform a pre-charge operation. If so, it will ramp up and run at the pre-charge frequency. Some of the pump protective functions are disabled during pre-charge operation. The drive will exit the pre-charge function when any of the below conditions are met: • The process feedback level reaches the pre-charge level (P4-01) • A multi-function digital input programmed for a Low Water Level switch deactivates (H1-oo = 8F) • The pre-charge timer expires (P4-03). Required Control Wiring No control wiring is required. An optional Low Water Level switch can be used to turn off the pre-charge function. Wire the switch into one the drive digital inputs and program the corresponding H1-oo parameter to 8F (the switch is normally open and closes during low water level). Start Up Procedure 1. Set all other parameters required for the application such as PI control loop, sleep, motor, and I/O parameters. However, this function can be used in conjunction across a wide range of applications using a PI control process loop. 2. Set the pre-charge level in parameter (P4-01). This is the process feedback level (PSI, depth, etc.) that must be achieved before the pre-charge function will turn off. 3. Set the pre-charge frequency reference in parameter P2-02. This is the frequency that the drive will run at during precharge. Set this value to reasonable speed that is above the minimum pump speed (P1-06) and close to the average running frequency of the drive controller. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 135 Start-Up Programming & Operation n Pre-Charge Function with One Lag Pump 4 4.5 iQpump Presets and Functions 4. 5. 6. Set the pre-charge timer in P4-03. When the drive goes into pre-charge mode, no low-water switch is wired to the drive, and if the pre-charge level (P4-01) cannot be obtained, the drive will exit the pre-charge function after the P4-03) time and begin normal PI control A multi-function digital input can be wired to and programmed for Pre-charge Disable if required (H1-oo = 8C). Parameter P1-30 configures the switch type (0: Normally Open, 1: Normally Closed). A multi-function digital output can be wired to and programmed to close whenever the pre-charge function is active (H2-oo = A4). Conditions for Entering Pre-charge Mode • • • • • Drive Ready or Sleeping (run command, not faulted, not in program mode). NOT in HAND Mode “Disable Pre-charge” digital input NOT closed. Pre-charge time set greater than zero (P4-03 > 0) If the Pre-charge level is greater than zero (P4-01 > 0) and the PID feedback is below the P4-01 level (Forward acting PID, b5-09 = 0). • If the Pre-charge level is greater than zero (P4-01 > 0) and the PID feedback is above the P4-01 level (Reverse acting PID, b5-09 = 1). Operation During Pre-Charge Mode • • • • • Drive will run at the Pre-Charge frequency (P4-02). The PID controller is disabled. The HOA keypad will display the message “Pre Chg Mode – Pre-chg Active”. The pre-charge digital output (H2-0o = A4) will close If the Pre-Charge frequency (P4-02) is set less than minimum pump speed (P1-06), an alarm “Freq. Ref < Pump Min P1-06” will be displayed and the drive will run at the minimum pump speed. Conditions for Exiting the Pre-Charge Mode • When Pre-charge timer expires (P4-03). The drive will always exit after the pre-charge timer expires. • When the “Disable Pre-Charge” digital input (H1-oo = 8C) is closed, even momentarily • When the PID feedback satisfies Pre-charge level (P4-01): Feedback is greater than Pre-Charge Level (P4-01) (forward-acting PID, b5-09 = 0) Feedback is less than Pre-Charge Level (P4-01) (reverse-acting PID, b5-09 = 1) • When the “Low Water” digital input (H1-oo = 8C) deactivates. A digital input must be programmed to “Low Water” (H1-0o = 8F). The input is configured in P1-30 (0: normally open, 1: normally closed). Related Parameters No. 136 Parameter Name P4-01 Pre-Charge Level P4-02 Pre-Charge Frequency P4-03 Pre-Charge Time P4-05 Pre-Charge Loss of Prime Level P4-06 Pre-Charge Frequency 2 P4-07 Pre-Charge Time 2 Setting Values Default: 0.0 PSI Min.: 0.0 Max.: 6000.0 Default: 0.0 Hz Min.: 0.0 Max.: [E1-04] Default: 0.0 min Min.: 0.0 Max.: 3600.0 Default: 0.0 A Min.: 0.0 Max.: 1000.0 Default: 0.0 Hz Min.: 0.0 Max.: [E1-04] Default: 0.0 min Min.: 0.0 Max.: 3600.0 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions No. Parameter Name P4-08 Setting Values Default: 0.0 A Min.: 0.0 Max.: 1000.0 Pre-Charge Loss of Prime Level 2 H1 Multi-Function Digital Input Settings H1-oo Setting 8C Function Disable Pre-Charge Description Closed: Pre-Charge disabled. H2 Multi-Function Digital Output Settings H2-oo Setting A4 Function Pre-Charge Description Closed: Drive is in Pre-Charge mode. P re -C ha rg e Sing le speed – C om plete via tim er R un C omm an d Ou tpu t F requen cy “Pre-cha rge Active” M essage & D igital Ou tpu t (H 2-0x = A4) P4-02 – Pre-cha rge F requen cy PID N OT disab led P 4-03 Pre-cha rge T im e P4-01 Pre-cha rge level = 0.0 AND P4-07 Pre-cha rge T im e 2 = 0.0 m in Figure 4.14 Pre-Charge Single Speed Complete via Timer P re -C ha rg e D ua l speed – C om plete via tim er R un C omm an d P4-06 – Pre-cha rge F requen cy 2 “Pre-cha rge Active” M essage & D igital Ou tpu t (H 2-0x = A4) P4-02 – Pre-cha rge F requen cy P 4-03 Pre-cha rge T im e P4-07 Pre-cha rge T im e 2 PID N OT disab led Start-Up Programming & Operation Ou tpu t F requen cy P4-01 Pre-cha rge level = 0.0 Figure 4.15 Pre-Charge Dual Speed Complete via Timer 4 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 137 4.5 iQpump Presets and Functions P re - C ha rg e C om plete via PID F eedba ck (N orm al Acting PID) R un C omm an d PID F eedba ck Ou tpu t F requen cy P4-01 – Pre-cha rge Le vel P4-02 – Pre-cha rge F requen cy P4-03 Pre-cha rge T im e “Pre-cha rge Active” M essage & D igital Ou tpu t (H 2-0x = A4) b5-01 PID Se lect = 1 (Enab led) AND b5-09 Ou tpu t Le vel Se l = 0 (N orm al C ha racter) Figure 4.16 Pre-Charge Complete via Normal PID Feedback n Setpoint Boost after Lag Pump De-Staging When a lag pump is de-staged (turned off), there can be a sudden drop in pressure in the system due to the pump de-staging. The Setpoint Boost function will dampen the shock load (pressure dip) to the system by temporarily raising the PI setpoint of the drive controller during de-staging. The function will raise the setpoint to the measured feedback value at the time of de-staging for the time set in P3-11. When the P3-11 time expires, the setpoint will return to the Q1-01 value and the drive operates normally. The intention of the feature is to get the drive to begin accelerating as soon as a pump is de-staged, thus limiting the shock to the system since the PI controller would tell the drive to accelerate anyway in response the de-staged pump. It is not intended to regulate at the boosted setpoint for a long period of time. • The maximum PI setpoint is limited to the Q1-01 setpoint plus the P3-10 (Max Boost at De-Stage) setting. • This feature cannot decrease the setpoint, therefore the function is disabled if b5-09 = 1 (inverse acting). • If the iQpump controller calls for a lag pump to be staged during the P3-11 time, the staging will occur with the Setpoint Boost function being immediately disabled. • Setting either P3-10 or P3-11 to zero disables the Setpoint Boost function. • The PI control loop is active during Setpoint Boost. • The default setting for P3-10 is 0.0 PSI and P3-11 is 5.0 sec. Start Up Procedure 1. Set all other parameters required for the application such as PI control loop, sleep, motor, and I/O parameters. Refer to Vertical Turbine Controller (VTC) on page 133 for an example. However, this function can be used in conjunction across a wide range of applications using a PI control process loop with multiple lag pumps that are staged and destaged 2. Set the maximum Setpoint Boost in parameter (P3-10). This is set in the selected system units (PSI, etc.). When a de-staging occurs and Setpoint Boost is to occur, the PI feedback level temporarily becomes the PI setpoint. Parameter P3-10 limits how much the PI setpoint can be raised. 3. Set the Setpoint Boost time in parameter P3-11. This sets how long the Setpoint Boost function will boost the PI setpoint. After the P3-11 time expires, the PI setpoint will return to the Q1-01 setting. Related Parameters No. 138 Parameter Name b5-09 PID Output Level Selection P3-10 Setpoint Boost Maximum at De-Stage P3-11 Setpoint Boost after De-Stage Time Setting Values Default: 0 Range: 0, 1 Default: 0.0 PSI Min.: -20.0 Max.: 20.0 Default: 5.0 s Min.: 0.0 Max.: 60.0 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions No. Q1-01 Parameter Name PID Controller Setpoint 1 Setting Values Default: 0.0 Min.: 0.0 Max.: 6000.0 n Frequency Reduction after Lag Pump Staging When a lag pump is staged (turned on), there can be a sudden increase in pressure in the system due to the pump staging on. The Frequency Reduction function will dampen the shock load (pressure spike) to the system by temporarily limiting (lowering) the drive controller output frequency during pump staging. The function will limit the output frequency at time of de-staging for the time set in P3-07. When the P3-07 time expires, the frequency limit is removed and the drive operates normally. The intention of the feature is to get the drive to begin decelerating as soon as a pump is staged to limit the shock to the system, as the PI controller would tell the drive to decelerate in response the staged on pump. It is not intended to regulate at the limited output frequency for an extended period of time. Note: 1. When a lag pump is staged on, the drive will upper-limit the output frequency for the P3-07 (Frequency Reduction Time) setting. The output frequency limit is determined by subtracting parameter P3-06 (Frequency Reduction at Staging) from parameter P3-03 (MaxMulti Level). The default setting for P3-03 is 59.0 Hz, P3-06 is 0.0 PSI, and P3-07 is 5.0 sec. 2. The drive integrator will be limited to prevent wind-up and ensure a smooth transition back out of frequency limit. 3. Once the P3-07 time expires, the upper-limit will be removed and the drive will operate normally. 4. If the drive calls for de-staging a pump during the P3-07 time, the de-stage will be allowed to happen, and normal PI operation will immediately resume. 5. If either P3-06 or P3-07 is set to zero, this feature will not operate. Start Up Procedure 1. Set all other parameters required for the application such as PI control loop, sleep, motor, and I/O parameters. Refer to Vertical Turbine Controller (VTC) on page 133 for an example. However, this function can be used in conjunction across a wide range of applications using a PI control process loop with multiple lag pumps that are staged and destaged. 2. Set the amount of frequency reduction at staging in parameter P3-06. When a staging occurs, the output frequency is limited to P3-03 – P3-06. 3. Example: If P3-03 = 59 Hz (default) and P3-06 is set to 3 Hz, the output frequency will be limited to 56 Hz. Set the Frequency Reduction time at staging in parameter P3-07. This sets how long the output frequency will be limited during pump staging. After the P3-07 time expires, the PI controller will return to normal. Related Parameters Parameter Name b5-09 PID Output Level Selection P3-10 Setpoint Boost Maximum at De-Stage P3-11 Setpoint Boost after De-Stage Time Q1-01 PID Controller Setpoint 1 Setting Values Default: 0 Range: 0, 1 Default: 0.0 PSI Min.: -20.0 Max.: 20.0 Default: 5.0 s Min.: 0.0 Max.: 60.0 Default: 0.0 Min.: 0.0 Max.: 6000.0 Start-Up Programming & Operation No. 4 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 139 4.5 iQpump Presets and Functions n Using the DO-A3 Option for Additional Lag Pumps The drive comes standard with three output relays capable of controlling three lag pumps. With the addition of a DO-A3 card installed in the drive, two additional lag pumps can be controlled bring the total to five lag pumps. Required Control Wiring Install the DO-A3 option card on the CN5-A, CN5-B, or CN5-C option connector on the drive. Refer to the DO-A3 Installation Manual packaged with the option for installation and wiring instructions. The option card has two relay outputs on terminal block 1 (TB1) and 6 photocoupler outputs on terminal block 2 (TB2). the drive uses only the relay outputs on terminal block 1. Start Up Procedure for Controlling a Lead Pump plus Five Lag Pumps 1. Install and wire the DO-A3 as indicated in the option installation manual. 2. Set all other parameters required for the application such as PI control loop, sleep, motor, and I/O parameters. 3. Program drive parameters with the values shown in Table 4.7 to correctly control each lag pump. Lag Pump Number 1 2 3 4 5 Terminal Location Control Board DO-A3 Option Table 4.7 Lag Pump Settings Terminal Numbers M1-M2 M3-M4 MD-MF M1-M2 M3-M4 Parameter H2-01 H2-02 H2-03 F5-07 F5-08 Setting 80 81 82 83 84 iQPump 1000 M1 Pressure Feedback H3-09 = B (PID Feedback) H2-01 = 80 LAG PUMP 1 H2-02 = 81 LAG PUMP 2 H2-03 = 82 LAG PUMP 3 F5-07 = 83 LAG PUMP 4 F5-08 = 84 LAG PUMP 5 M2 A2 M3 M4 MD P1-01 = 1 (Contactor Multiplex) MF M1 M2 DO-A3 F5-09 = 2 M3 M4 U V W LEAD PUMP 1 Figure 4.17 Controlling Five Lag Pumps with DO-A3 Option 140 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions n Software Multiplexing Setup Wiring the Drive RS-485 Network Connections Reservoir Process Supply Pump Pump Pump Pump iQpump iQpump iQpump iQpump R+ R- S+ S- R+ R- S+ S- R+ R- S+ S- R+ R- S+ S- RS-485 Network Figure 4.18 System Overview Perform the following steps to make the RS-485 network connections between all drives that will be multiplexed: 1. Jumper terminals (R+ to S+) and jumper terminals (R- to S-) terminals on each individual drive according to Figure 4.19. Drive X R+ R- S+ S- 2. 3. 4. Start-Up Programming & Operation Figure 4.19 Drive Terminal Jumpers Use shielded communication cable for steps 3 and 4 to connect the drives in a daisy chain manner according to Figure 4.20. Daisy chain the (R+ to S+) terminals between each drive. Daisy chain the (R- to S-) terminals between each drive. Drive 1 Drive 2 Drive 3 4 R+ R- S+ S- R+ R- S+ S- R+ R- S+ S- Figure 4.20 Daisy Chain Three Drives YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 141 4.5 iQpump Presets and Functions Setting the Drive Networking Parameters 1. 1. Set parameter H5-01, Serial Node Address, on each drive. Note: 2. Note: 3. 4. Note: For optimal performance, use consecutive numbers starting from 1. Parameter setting H5-01 must be unique for each drive. Set parameter P9-25, Highest Node Address, on each drive. For optimal performance, set to highest H5-01 value. This setting must be the same for all the drives on the network. Set P1-01 to 3 (MEMOBUS/Modbus Network) on all the drives. Cycle main power to all networked drives. The H5-01 setting will not take effect until power is cycled to the drive and may cause communication errors and unexpected behavior. Verifying the iQpump1000 Drive Network Communications Access monitor U9-02, Network Activity, and verify: • No drives have a value of 0 <-> • All drives are receiving valid data indicated by a regular change in the monitor value. • At least one drive has the unit <M>, while the others have the unit <+>. Table 4.8 Network Connectivity Information Network State Top Line on Home Screen (o1-12 = 1) <M> CONNECTED Drive is the Master and is communicating with another drive. Pump Off Network U5-99= 100.0PSI U1-02= 0.00Hz U1-91= 62.8PSI U9-02 Network Activity - MONITR - Network Activity U9-02= 9453<M> U1-02= 0.00Hz U1-91= 62.8PSI Home <- MONITOR - > <+> CONNECTED Drive is a node on the network and is communicating with a Master. Pump Off Network U5-99= 100.0PSI U1-02= 0.00Hz U1-91= 62.8PSI Drive is not able to communicate to any other drives. DRV RDY Network Activity U9-02= 324<+> U1-02= 0.00Hz U1-91= 62.8PSI Home Pump Off Network U5-99= 100.0PSI U1-02= 0.00Hz U1-91= 62.8PSI FWD - MONITR - <- MONITOR - > <-> DISCONNECTED DRV RDY FWD - MONITR - <- MONITOR - > DRV RDY Network Activity U9-02= 0<-> U1-02= 0.00Hz U1-91= 62.8PSI Home FWD If a drive displays U9-02 = 0 <->: • Check physical connections. • Verify the H5-oo serial communication settings. • Confirm the P9-25 and P9-27 settings on all the drives. P9-25 should be set to the highest H5-01 address and at least one drive should have P9-27 set to 0. • Cycle main power. Multiplexing Principle Always observed by system: • New drives start as Lead and run in PI mode. • Only the Lead drive can request staging and de-staging. • Staging will start a new Lead drive and make the old Lead drive into a Lag drive. 142 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions • De-staging will stop the current Lead drive and restore the previous drive as the Lead drive. Drive Run Order U9-04, Running Queue No: • Shows the position in the iQpump MEMOBUS running queue. • Set U9-04 to 0 for pumps that are not running. • Set U9-04 to 1 on the first pump that came on and is still running. • Set U9-04 to 2 on the second pump that came on and is still running. • Set U9-04 to the number of pumps running for the current Lead drive. Multiplex Status Display Table 4.9 Multiplex Status Display Network State Display - MODE Drive is not able to accept commands from the iQpump MEMOBUS network because the drive is not in AUTO Mode run. DRV RDY Pump Off Network U5-99= 100.0PSI U1-02= 0.00Hz U1-91= 62.8PSI Home - MODE Drive is in AUTO Mode and waiting for a run command from the iQpump MEMOBUS network. DRV RDY Wait for Net Cmd U5-99= 100.0PSI U1-02= 0.00Hz U1-91= 62.8PSI Home - MODE Drive is in AUTO Mode, Lead operation and is currently regulating the system using PI control. DRV RDY Lead: Setpoint U5-99= 100.0PSI U1-02= 52.38Hz U1-91= 62.8PSI - MODE Drive is in Auto Mode, Lag operation and is holding the speed at the time it made the switch from being a lead drive to a lag. Speed is held until P9-07 time expires. The Home screen will display U1-01 instead of U5-99. Start-Up Programming & Operation Home DRV RDY Lag: Fixed Hold U1-01= 59.41HZ U1-02= 59.41Hz U1-91= 99.8PSI 4 Home - MODE Drive is in Auto Mode, Lag operation and is running at the speed set in P9-06. The Home Screen will display U1-01 instead of U5-99. DRV RDY Lag: Fixed P9-06 U1-01= 55.00HZ U1-02= 55.00Hz U1-91= 99.9PSI Home YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 143 4.5 iQpump Presets and Functions Network State Display - MODE - DRV RDY Lag: Follow Lead U1-01= 51.37HZ Drive is in AUTO Mode, Lag operation and is following the speed of the current Lead drive. The Home screen will display U1-01 instead of U5-99. U1-02= 51.35Hz U1-91= 98.9PSI Home - MODE - DRV RDY Lead: Geothermal U1-01= 48.00HZ U1-02= 44.82Hz U1-80= 83.6˚F Drive is in AUTO Mode, Lead operation with Geothermal Enabled. The Home screen will display U1-01 instead of U5-99 Home PI Feedback via Network The Network PI Feedback comes from a drive on the network with a valid analog PI feedback source and can be used as the primary or secondary feedback source for a networked drive. Set P9-02 to 0 if a drive has an analog PI feedback device installed and switching to network as a backup is not desired. if a drive has an analog PI feedback device installed and the network PI feedback is considered as a backup, set P9-02 to 1 for no alarm message when switched and set P9-02 to 2 for an alarm. Set P9-02 to 3 if a drive has no analog PI feedback device installed and relies solely on the analog PI feedback of another networked drive. Note: Connect an analog PI feedback device to each drive for best performance. Related Parameters No. 144 Parameter Name H5-01 Drive Node Address P1-01 Pump Mode P9-02 Feedback Source P9-25 Highest Node Address P9-27 Network Recovery U9-02 U9-04 Network Activity Running Queue Number Setting Values Default: 1F (Hex) Min.: 0 Max.: FF Default: 0 Range: 0, 1, 3 Default: 0 Range: 0 to 3 Default: 08h Min.: 02h Max.: 08h Default: 1 Range: 0 to 3 No signal output available No signal output available YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions n Simple Duplex System Application Example A customer requires a duplex system with the following capabilities: • Control the system pressure using two drives (no PLCs). • Alternate drives everyday to even out the pump wear. • Toggle switch for Run command. • Each drive will have its own feedback transducer. Due to the shut-off valves, the network feedback should not be used as a backup. • Pump is at optimal running speed when running at fixed speed is 54.0 Hz. • Setpoint is 100 PSI, feedback scale is 145 PSI, start level is 80 PSI. RUN S1 S1 SN SN Drive A Drive B 15 HP 15 HP +V PRESSURE FEEDBACK B PRESSURE FEEDBACK A RUN A1 A2 AC R+ R- S+ S- +V A1 A2 AC R+ R- S+ S- Figure 4.21 Simplified Wiring Diagram Start-Up Programming & Operation Table 4.10 Related Parameters for Simple Duplex System Example Description Drive A <1> Drive B <1> Run Source: 1 (Terminals) b1-02 = 1 b1-02 = 1 Node Address H5-01 = 1 H5-01 = 2 Highest Node Address P9-25 = 2 P9-25 = 2 Pump Mode: 3 (Network) P1-01 = 3 P1-01 = 3 Feedback Source: 0 (Analog) P9-02 = 0 P9-02 = 0 Lag Fixed Speed P9-06 = 54.0 Hz P9-06 = 54.0 Hz Setpoint U5-99 = 100 PSI U5-99 = 100 PSI Start Level P1-04 = 80 PSI P1-04 = 80 PSI <1> All other multiplexing and alternation parameters are set to default settings. Duplex System with Fine Tuning Application Example The customer would like to run the second drive for 10 to 20 seconds at minimum speed then shut it off, letting the first drive run at maximum. This will then run the second drive again and the cycle will repeat. The customer must also account for system losses when running both pumps by boosting the setpoint by 5 PSI. In the event that the pressure exceeds 125 PSI, the second drive should de-stage if both drives are running. If the pressure exceeds 140 PSI, a high feedback fault should occur and stop the drive. There are multiple methods to handle the pump cycling problem: • Lower the lag fixed speed (P9-06) • Decrease the lag fixed speed delay (P9-07) • Increase the staging frequency level (P9-09) • Increase the staging delay time (P9-11) • Increase the de-staging delay time (P9-15) • Increase the stabilization time (P9-16) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 145 4 4.5 iQpump Presets and Functions • Increase both the Add Freq Level and Add Dly Time Table 4.11 Related Parameters for Duplex System with Fine Tuning Application Example Description Drive A <1> Drive B <1> Run Source: 1 (Terminals) b1-02 = 1 b1-02 = 1 Node Address H5-01 = 1 H5-01 = 2 Highest Node Address P9-25 = 2 P9-25 = 2 Pump Mode: 3 (Network) P1-01 = 3 P1-01 = 3 Feedback Source: 0 (Analog) P9-02 = 0 P9-02 = 0 Lag Fixed Speed P9-06 = 54.0 Hz P9-06 = 54.0 Hz Setpoint U5-99 = 100 PSI U5-99 = 100 PSI Start Level P1-04 = 140 PSI P1-04 = 140 PSI High Feedback Quick De-Stage P9-18 = 89.3% P9-18 = 89.3% Setpoint Modifier P9-17 = 5.0 PSI P9-17 = 5.0 PSI Add Drive Frequency Level P9-09 = 59.0 Hz P9-09 = 59.0 Hz Add Drive Delay P9-11 = 12.0 s P9-11 = 12.0 s <1> All other multiplexing and alternation parameters are set to default settings. Duplex System with Jockey Pump Example SYSTEM PRESSURE FEEDBACK A customer requires a pump system with the following requirements: • One small pump (the Jockey pump) will run the system during off-peak times. • Two larger pumps will run the system when the demand is higher. • The Jockey pump should not run when the two larger pumps are running. • Pump wear is still an issue, but it is expected that the small pump will run longer hours and will always run first after a loss of power. • The feedback scale is 145 PSI. • There is only one feedback transducer in the system. S1 S1 SN SN (Jockey Pump) 10 HP S1 SN Drive B 15 HP +V +V +V A1 A1 A1 A2 A2 A2 AC AC AC R+ R- S+ S- R+ R- S+ S- Drive C 15 HP R+ R- S+ S- Figure 4.22 Simplified Wiring Diagram Table 4.12 Related Parameters for Duplex System with Jockey Pump Example Description Jockey Pump <1> Drive B <1> Node Address H5-01 = 1 H5-01 = 2 Highest Node Address P9-25 = 3 P9-25 = 3 Pump Mode: 3 (Network) P1-01 = 3 P1-01 = 3 Feedback Source: 0 (Analog), 3 P9-02 = 0 P9-02 = 3 (Network) Lag Drive Speed: 0 (Always), 2 P9-05 = 2 P9-05 = 0 (Turn Off) Allow Net Run: 0 (Always), 2 (First P9-20 = 2 P9-20 = 0 Only) 146 Drive C <1> H5-01 = 3 P9-25 = 3 P1-01 = 3 P9-02 = 3 P9-05 = 0 P9-20 = 0 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.5 iQpump Presets and Functions Jockey Pump <1> P9-21 = 7 P9-24 = 0 U5-99 = 100 PSI P1-04 = 80 PSI Description Run Priority Lead Swap @ Sleep Setpoint Start Level Drive B <1> P9-21 = 8 P9-24 = 1200 s U5-99 = 100 PSI P1-04 = 80 PSI Drive C <1> P9-21 = 8 P9-24 = 1200 s U5-99 = 100 PSI P1-04 = 80 PSI <1> All other multiplexing and alternation parameters are set to default settings. Triplex System Example A customer who currently runs a duplex system would like to retrofit an existing triplex system with the following requirements: • Three similarly sized pumps would run the system. • A maximum of two drives should be running at any point; the third drive is a backup. • Alternation should only happen when pumps are not running (sleeping). • If one of the analog pressure feedback transducers should fail, read from a working one and notify the customer of the failure by the alarm display. • Setpoint is 90 PSI, feedback scale is 145 PSI, start level is 75 PSI. S1 S1 S1 SN SN SN Drive A 25 HP +V A1 A2 AC R+ R- S+ S- Drive C 25 HP +V SYSTEM PRESSURE FEEDBACK SYSTEM PRESSURE FEEDBACK SYSTEM PRESSURE FEEDBACK +V Drive B 25 HP A1 A2 AC R+ R- S+ A1 A2 AC S- R+ R- S+ S- Figure 4.23 Simplified Wiring Diagram Table 4.13 Related Parameters for Triplex System Example Drive A <1> Drive B <1> H5-01 = 1 H5-01 = 2 P9-25 = 3 P9-25 = 3 P1-01 = 3 P1-01 = 3 Drive C <1> H5-01 = 3 P9-25 = 3 P1-01 = 3 P9-02 = 2 P9-02 = 2 P9-02 = 2 P9-04 = 3 P9-23 = 2 U5-99 = 90 PSI P1-04 = 75 PSI P9-04 = 3 P9-23 = 2 U5-99 = 90 PSI P1-04 = 75 PSI P9-04 = 3 P9-23 = 2 U5-99 = 90 PSI P1-04 = 75 PSI Start-Up Programming & Operation Description Node Address Highest Node Address Pump Mode: 3 (Network) Feedback Source: 2 (Analog ->Net, with Alarm) Alternation Mode: 3 (FIFO @ Sleep) Maximum Running Pumps Setpoint Start Level 4 <1> All other multiplexing and alternation parameters are set to default settings. n Multiplexing Stop History Many irrigation-pumping skids consist of a PM pump (Pressure Maintenance) and typically two larger booster pumps to maintain high flow peak demands. In many cases depending on the number of irrigation zones in combination with the type of sprinkler heads used, the flow demand fluctuates and may not require the use of both larger booster pumps at the same time until higher flow rates are required. The drive Controller "Run Stop" history ensures that both booster pumps alternate each run cycle. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 147 4.5 iQpump Presets and Functions Setting 0 1 2 Note: Table 4.14 P9-01, Lead Drive Selection, Detection Settings Description Next Available Select next available drive on the network as the new lead drive Lowest Runtime (default) Select the iQpump Controller with the lowest runtime as the new lead drive Stop History Select the iQpump that had been stopped for the longest time. The new lead drive selection also applies to Alternation (P9-03 > 0) and will use the Stop History list when finding the alternate. Triplex Irrigation Booster System Example When pressure is dropping, the PM Pump (if installed) will attempt to return the system pressure to the desired setpoint level. If the PM Pump is not able to return the system to the setpoint pressure, typically due to a greater flow demand, the booster pump #1 will be staged on. The drive controller will speed up or slow down the pump as needed to maintain the system pressure. When flow decreases and the pump system is no longer required to run, the system will go to sleep waiting for the pressure to drop. On the next run cycle the PM pump will start up again, and instead of running booster pump #1, booster pump #2 is stages on, since booster #1 ran during the last cycle. This method ensures that during normal operation both booster pumps will operate evenly as lead or lag pumps each run cycle. A triplex irrigation booster system has one PM Pump (pressure maintenance) and two larger booster pumps of the same horsepower. The customer would like to ensure that the PM Pump is also the lead pump to recharge the system during low flow usage, but during high demands the booster pumps alternate on each run cycle or if required will both run to support very high flow demands. • Jockey/PM Pump will also be lead to start. • Jockey/PM Pump will stage booster pump 1 or 2 and stay running for 20 seconds and then shut off. • Booster pump 1 will run system and if required, call for booster pump 2 or vice versa. • On sleep mode, the lead drive for starting will swap back to Jockey/PM Pump. • System setpoint 100 PSI. • Pressure drop of 10 PSI will start the Jockey pump. • All drives have individual transducers rated 200 PSI maximum, but if there is a transducer failure, switch to network. Triplex Irrigation Booster System Related Parameters Parameter No. H5-01 P1-01 P1-03 P1-04 P9-01 P9-02 P9-07 P9-20 P9-21 P9-24 P9-25 U5-99 148 Parameter Name Drive Node Address Pump Mode Feedback Device Scaling Start / Draw Down Level Lead Drive Selection Feedback Source Lag Fixed Speed Delay Allow Network Run Run Priority Lead Swap at Sleep Highest Node Address PID Setpoint Command Table 4.15 Related Parameters PM Pump 1 3 200 PSI -10.0 PSI 2 2 20 s 2 7 0s 3 100 PSI Booster Pump 1 2 3 200 PSI -10.0 PSI 2 2 5s 0 8 1s 3 100 PSI Booster Pump 2 3 3 200 PSI -10.0 PSI 2 2 5s 0 8 1s 3 100 PSI YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters 4.6 Basic iQpump Setup and Application Preset Parameters This section explains the basic settings required for initial drive operation. Checking these basic parameter settings will help to ensure a successful drive start-up. Refer to Parameter List on page 255 for a complete listing of drive parameters if more information is required for parameters not listed in this section. n A1-01: Access Level Selection Allows or restricts access to drive parameters. No. A1-01 Parameter Name Access Level Selection Setting Range 0 to 3 Default 2 Setting 0: Operation only Access to only parameters A1-01, A1-04, and all U monitor parameters. Setting 1: User Parameters Access to only a specific list of parameters set to A2-01 through A2-32. These User Parameters can be accessed using the Setup Mode of the digital operator. Setting 2: Advanced Access Level (A) and Setup Access Level (S) All parameters can be viewed and edited. Setting 3: Lock Parameters Notes on Parameter Access • If the drive parameters are password protected by A1-04 and A1-05, parameters A1-00 through A1-03, A1-06, and all A2 parameters cannot be modified. • If a digital input terminal programmed for “Program lockout” (H1-oo = 1B) is enabled, parameter values cannot be modified, even if A1-01 is set to 1 or 2. • If parameters are changed via serial communication, it will not be possible to edit or change parameter settings with the digital operator until an Enter command is issued to the drive from the serial communication. n A1-03: Initialize Parameters Resets parameters to default values or performs an Application Preset for fan or pump applications. After initialization, the setting for A1-03 automatically returns to 0. Parameter Name A1-03 Initialize Parameters Setting Range 0, 1110, 2220, 3330, 5550, 6008, 6009, 6010, 6011, 7770 Default 0 Setting 1110: User Initialize Resets parameters to the values selected by the user as User Settings. User Settings are stored when parameter o2-03 is set to “1: Set defaults”. Note: User Initialization resets all parameters to a user-defined set of default values previously saved to the drive. Set parameter o2-03 to 2 to clear the user-defined default values. Setting 2220: 2-Wire Initialization Resets parameters to default settings with digital inputs S1 and S2 configured as Forward run and Reverse run, respectively. Setting 3330: 3-Wire Initialization Resets parameters to default settings with digital inputs S1, S2, and S5 configured as Run, Stop, and Forward/Reverse respectively. Refer to Setting 0: 3-Wire Sequence on page for more information on digital input functions. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 149 Start-Up Programming & Operation No. 4 4.6 Basic iQpump Setup and Application Preset Parameters Stop switch (NC contact) Operation switch (NO contact) S1 S1 FWD Run/Stop S2 SN Run command (Run on momentary close) Stop command (Stop on momentary open) SN Sequence input common 3-Wire Control 2-Wire Control Figure 4.24 2 & 3-Wire Control Wiring Examples Notes on Parameter Initialization The parameters shown in Table 4.16 will not be reset when the drive is initialized by setting A1-03 = 2220 or 3330. Table 4.16 Parameters Not Changed by Drive Initialization No. A1-00 E1-03 F6-08 L8-35 o2-04 Parameter Name Language Selection V/f Pattern Selection Communication Parameter Reset Installation Selection Drive/kVA Selection Setting 5550: Terminal/Control Initialize An oPE04 error appears on the digital operator when a terminal block with settings saved to its built-in memory is installed in a drive that has edited parameters. Set A1-03 to 5550 to use the parameter settings saved to the terminal block memory. Application Presets are available to facilitate drive setup for commonly used applications. Selecting one of these Application Presets automatically assigns functions to the input and output terminals and sets a predefined group of parameters to values appropriate for the selected application. In addition, the parameters most likely to be changed are assigned to the group of User Parameters, A2-01 through A2-16. User Parameters are part of the Setup Group, which provides quicker access by eliminating the need to scroll through multiple menus. Refer to Pump Application Presets on page 118 for detailed information on Application Presets. Setting 6008: Pressure Control Application Preset for Pressure Control applications. Refer to Pump Application Presets on page 118 for a list of parameters and default values for this Application Preset. Setting 6009: Pump Down Level Application Preset for Pump Down Level applications. Refer to Pump Application Presets on page 118 for a list of parameters and default values for this Application Preset. Setting 6010: Geothermal Mode Application Preset for Geothermal Mode. Refer to Pump Application Presets on page 118 for a list of parameters and default values for this Application Preset. Setting 6011: VTC Pressure Mode Application Preset for VTC Pressure Mode. Refer to Pump Application Presets on page 118 for a list of parameters and default values for this Application Preset. Setting 7770: General Purpose General Purpose Application Preset. Refer to Pump Application Presets on page 118 for a list of parameters and default values for this Application Preset. 150 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters n b1-01: Frequency Reference Selection 1 Selects the frequency reference source 1 for the REMOTE mode. Note: If a Run command is input to the drive but the frequency reference entered is 0 or below the minimum frequency, the RUN indicator LED on the digital operator will light and the STOP indicator will flash. No. b1-01 Parameter Name Frequency Reference Selection 1 Setting Range 0 to 5 Default 0 In order to run the drive and motor, the drive must receive a Run command and an Auto Setpoint command. Parameter b1-01 specifies the origin of the Auto setpoint when in AUTO Mode. Switch to AUTO mode by pressing the AUTO button on the HOA keypad while the drive is stopped. Note: If a Run command is input to the drive without a corresponding Auto setpoint, the Run indicator on the HOA keypad will turn on and the STOP indicator on the keypad will blink. If the drive should follow the “HAND Reference” set by the HOA keypad, use HAND Mode by pressing the HAND key and set P5-01 to “1: Hand Reference (P5-02).” The HAND reference can then be entered into the U1-01 monitor parameter in the “-DRIVE- ” Menu. The drive offers the ability to provide four types of “Auto Setpoint” reference sources. These Auto Setpoint reference sources are determined by the setting of b1-01 and the drive set to AUTO Mode by pressing the AUTO key on the keypad. Prior to programming, it is recommended to select the system units (P1-02) and the feedback device, Scaling (P1- 03) first. P1-03 will automatically scale the drive setpoint. Example: P1-02 = 1: PSI P1-03 = 200, feedback range = 200 PSI. If the drive should follow an “Auto Set-Point” set by the HOA keypad: Set b1-01 to “0: Operator” (factory default). The Auto setpoint can then be entered into the U1-01 monitor parameter in the “-DRIVE-” menu. Setting 0: Operator (HOA keypad) Using this setting, the frequency reference can be input by: • switching between the multi-speed references in the d1-oo parameters. • entering the frequency reference on the operator keypad. This selection will also switch PID setpoint to Q1-01. Setting 1: Terminals (analog input terminals) Note: When b1-01 is set to 1 (Terminals) and P5-01 is set to 0 (HAND Mode Reference), the setpoint and the HAND reference are determined by the external analog signal. Voltage Input Voltage input can be used at any of the three analog input terminals. Make the settings as described in Table 4.17 for the input used. Table 4.17 Analog Input Settings for Frequency Reference Using Voltage Signals Parameter Settings Terminal A1 A2 A3 Signal Level 0 to 10 Vdc 0 to 10 Vdc Bipolar 0 to 10 Vdc 0 to 10 Vdc Bipolar 0 to 10 Vdc 0 to 10 Vdc Bipolar Signal Level Selection H3-01 = 0 H3-01 = 1 H3-09 = 0 H3-09 = 1 H3-05 = 0 H3-05 = 1 Notes Function Selection Gain Bias H3-02 = 0 (Frequency Reference Bias) H3-03 H3-04 – H3-10 = 0 (Frequency Reference Bias) H3-11 H3-12 Set jumper S1 on the terminal board to “V” for voltage input. H3-06 = 0 (Frequency Reference Bias) H3-07 H3-08 Set DIP switch S4 on the terminal board to “AI”. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Start-Up Programming & Operation Using this setting, an analog frequency reference can be entered as a voltage or current signal from terminals A1, A2, or A3. To set the drive to follow an “Auto Setpoint” set by the analog input, set b1-01 to 1 (Terminals) and connect a potentiometer or external signal to the drive. 4 151 4.6 Basic iQpump Setup and Application Preset Parameters Drive Drive +V 10.5 V, 20 mA power supply 2k 0 to 10 V A1 Analog Input 1 A2 Analog Input 2 +V 10.5 V, 20 mA power supply +10 V Customer +/- 10 V Supply 0V OR 4k 0 to 10 V A1 Analog Input 1 A2 Analog Input 2 A3 Analog Input 3 A3 Analog Input 3 AC Analog input common AC Analog input common Common Figure 4.25 Setting the Frequency Reference as a Voltage Signal at Terminal A1 Current Input Input terminals, A1, A2, and A3 can accept a current input signal. Refer to Table 4.18 for an example to set terminal A2 for current input. Table 4.18 Analog Input Settings for Frequency Reference Using a Current Signal Terminal A2 Signal Level 4 to 20 mA Signal Level Selection H3-09 = 2 0 to 20 mA H3-09 = 3 Parameter Settings Function Gain Selection H3-10 = 0 (Frequency Bias) Jumper S1 A1/A2/A3 Voltage/Current Selection H3-11 H3-12 Make sure to set jumper S1 on the terminal board to “I” for current input. Drive V I A1 A2 A3 Notes Bias +V 10.5 V, 20 mA power supply A1 Analog Input 1 0 or 4 to 20 mA A2 Analog Input 2 A3 Analog Input 3 AC Analog input common Figure 4.26 Setting the Frequency Reference as a Current Signal to Terminal A2 Switching between Main/Auxiliary Frequency References The frequency reference input can be switched between the analog terminals A1, A2, and A3 using multi-speed inputs. To use several speed references for a multi-step speed sequence, set the H1-oo parameters to 3, 4, 5, and 32. To assign the Jog reference to a digital input, set H1-oo to 6. Setting 2: Serial Communications This setting requires entering the frequency reference via the RS-485/422 serial communications port (control terminals R+, R-, S+, S-). To setup the drive to receive the “Auto Setpoint” from serial communication, set b1-01 to “2: Serial Com,” and connect the RS-422/RS-485 serial communications cable to terminals R+, R-, S+, and S- on the control I/O terminal block. Refer to 153 to see the connection diagram using a PC to provide the auto setpoint reference to the drive. 152 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters Figure 5.4 Terminating Resistor Modbus RTU Communications RS-422/RS-485 19.2 Kbps RS-485 Communication Connection Figure 4.27 PC or PLC Connection Diagram Setting 3: Option card This setting requires entering the frequency reference via an option board plugged into connector CN5-A on the drive control board. Consult the option board manual for instructions on integrating the drive with the communication system. Note: If the frequency reference source is set for Option PCB (b1-01 = 3), but an option board is not installed, an oPE05 Operator Programming Error will be displayed on the digital operator and the drive will not run. To setup the drive to receive the “Auto Setpoint” for a network communication option card, set b1-01 to “3: Option PCB”, and plug a supported communication option card into the drive control PCB. Consult the manual supplied with the option for instructions on integrating the drive into the network system. Refer to Option Installation on page 228 for a list of available drive network communication options. Setting 4: Pulse Train Input This setting requires a pulse train signal to terminal RP to provide the frequency reference. Follow the directions below to verify that the pulse signal is working properly. • Set b1-04 to 4 and set H6-01 to 0. • Set the H6-02 to the pulse train frequency value that equals 100% of the frequency reference. • Enter a pulse train signal to terminal RP and check for the correct frequency reference on the display. Setting 5: Geothermal Mode Refer to Geothermal Mode Application Preset on page 122 for details on how to use this function. n b1-02: Run Command Selection 1 Determines the Run command source 1 in AUTO Mode. The drive comes factory programmed for Start and Stop from the keypad, but the user can program the drive to receive a Run command from four different inputs: digital operator, terminals, serial communications, or an option PCB. To set the drive to receive the Run command from the HOA keypad, set b1-02 to “0: Operator,” and the HAND key will be used to provide the Run command to the drive. To set the drive to receive the Run command from the external terminals, set b1-02 to “1: Terminals” and initiate an external Run command by a contact closure between terminals S1 and SN. Note: No. b1-02 Using the external terminals requires setting the drive to AUTO Mode by pressing the AUTO key. Parameter Name Run Command Selection 1 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Setting Range 0 to 3 Default 0 153 Start-Up Programming & Operation Verifying the Pulse Train is Working Properly 4 4.6 Basic iQpump Setup and Application Preset Parameters Setting 0: Operator (HOA keypad) This setting requires entering the Run command via the HOA keypad AUTO key and also illuminates the HAND indicator on the digital operator. Setting 1: Control Circuit Terminal This setting requires entering the Run command via the digital input terminals using one of following sequences: • 2-Wire sequence 1: Two inputs (FWD/Stop-REV/Stop). Set A1-03 to 2220 to initialize the drive and preset terminals S1 and S2 to these functions. This is the default setting of the drive. • 2-Wire sequence 2: Two inputs (Start/Stop-FWD/REV). • 3-Wire sequence: Three inputs (Start-Stop-FWD/REV). Set A1-03 to 3330 to initialize the drive and preset terminals S1, S2, and S5 to these functions. Refer to Setting 0: 3-Wire Sequence on page . Setting 2: MEMOBUS/Modbus Communications This setting requires entering the Run command via serial communications by connecting the RS-485/422 serial communication cable to control terminals R+, R-, S+, and S- on the removable terminal block. Setting 3: Option Card This setting requires entering the Run command via the communication option board by plugging a communication option board into the CN5-A port on the control PCB. Refer to the option board manual for instructions on integrating the drive into the communication system. Note: If b1-02 is set to 3, but an option board is not installed in CN5-A, an oPE05 operator programming error will be displayed on the digital operator and the drive will not run. n b1-03: Stopping Method Selection Selects how the drive stops the motor when the Run command is removed or when a Stop command is entered. No. b1-03 Parameter Name Stopping Method Selection Setting Range 0 to 3 Default 0 Setting 0: Ramp to Stop When the Run command is removed, the drive will decelerate the motor to stop. The deceleration rate is determined by the active deceleration time. The default deceleration time is set to parameter C1-02. When the output frequency falls below the level set in parameter b2-01, the drive will start DC injection, Zero Speed Control, or Short Circuit Braking. Setting 1: Coast to Stop When the Run command is removed, the drive will shut off its output and the motor will coast (uncontrolled deceleration) to stop. The stopping time is determined by the inertia and the friction in the driven system. Run command Output frequency ON OFF Drive output is shut off Motor speed Figure 4.28 Coast to Stop Note: 154 After a stop is initiated, any subsequent Run command entered will be ignored until the minimum baseblock time (L2-03) has expired. Do not enter Run command until it has come to a complete stop. Use DC Injection at Start (Refer to b2: DC Injection Braking and Short Circuit Braking on page 258) or Speed Search (Refer to b3: Speed Search on page 259) to restart the motor before it has completely stopped. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters Setting 2: DC Injection Braking to Stop When the Run command is removed, the drive will enter baseblock (turn off its output) for the minimum baseblock time (L2-03). When the minimum baseblock time has expired, the drive will inject the amount DC Injection Braking is set in parameter b2-02 into the motor windings to brake the motor. The stopping time in DC Injection Braking to Stop is significantly faster compared to Coast to Stop. Run command ON OFF DC Injection Braking with the current set in b2-02 Output frequency Motor speed Motor coasts Minimum Baseblock Time (L2-03) Figure 4.29 DC Injection Braking to Stop DC Injection Braking time is determined by the value set to b2-04 and the output frequency at the time the Run command is removed. It can be calculated by: DC Injection brake time = (b2-04) x 10 x Output frequency Max. output frequency (E1-04) DC Injection braking time b2-04×10 b2-04 Output frequency when Stop command was entered 100% (Maximum output frequency) Figure 4.30 DC Injection Braking Time Depending on Output Frequency Note: If an overcurrent (oC) fault occurs during DC Injection Braking to Stop, lengthen the minimum baseblock time (L2-03) until the fault no longer occurs. Setting 3: Coast to Stop with Timer (Used for Back Spin Control on Vertical Turbine Pumps) When the Run command is removed, the drive coasts to a stop. If parameter b1-11 is set to zero, the coast-timer becomes a value determined by a combination of output frequency and the C1-02 parameter. However, if b1-11 is set greater than zero, the coast timer is set to b1-11. If the Run command is re-issued during the coast-timer time, the drive WILL restart when the coast-timer expires without the need to re-cycle the run command. The coast-timer will operate for both AUTO Mode and HAND Mode. The coast-timer will still operate when the drive goes to sleep then wakes up. Run command ON Output frequency OFF ON OFF ON Drive output shut off Run wait time t Figure 4.31 Coast to Stop with Timer YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 155 Start-Up Programming & Operation 10% 4 4.6 Basic iQpump Setup and Application Preset Parameters The wait time t is determined by the output frequency when the Run command is removed and by the active deceleration time. Run wait time t Active deceleration time Min Baseblock Time (L2-03) Output frequency when Stop command was entered Min output frequency 100% (Max output frequency) Figure 4.32 Run Wait Time Depending on Output Frequency n b3-01: Speed Search Selection at Start Determines if Speed Search is automatically performed when a Run command is issued. No. b3-01 Parameter Name Speed Search Selection at Start Setting Range 0, 1 Default 0 Setting 0: Disabled This setting starts operating the drive at the minimum output frequency when the Run command is entered. If external Speed Search 1 or 2 is already enabled by a digital input, the drive will start operating with Speed Search. Setting 1: Enabled This setting performs Speed Search when the Run command is entered. The drive begins running the motor after Speed Search is complete. n b5-01: PID Function Setting Enables and disables the PID operation and selects the PID operation mode. No. b5-01 Parameter Name PID Function Setting Setting Range 0, 1 Default 0 Setting 0: PID disabled Setting 1: Output frequency = PID output 1 The PID controller is enabled and the PID output builds the frequency reference. The PID input is D controlled. n b5-03: Integral Time Setting (I) Sets the time constant used to calculate the integral of the PID input. The shorter the integral time set to b5-03, the faster the offset will be eliminated. If the integral time is set too short, however, overshoot or oscillation may occur. To turn off the integral time, set b5-03 to 0.00. No. b5-03 Name Integral Time Setting (I) Setting Range 0.0 to 360.0 s Default 1.0 s n b5-09: PID Output Level Selection Reverses the sign of the PID controller output signal. Normally a positive PID input (feedback smaller than setpoint) leads to positive PID output. No. b5-09 Parameter Name PID Output Level Selection Setting Range 0, 1 Default 0 Setting 0: Normal Output A positive PID input causes an increase in the PID output (direct acting). Setting 1: Reverse Output A positive PID input causes a decrease in the PID output (reverse acting). 156 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters n b5-38, b5-39: PID Setpoint User Display, PID Setpoint Display Digits When parameter b5-20 is set to 3, parameters b5-38 and b5-39 set a user-defined display for the PID setpoint (b5-19) and PID feedback monitors (U5-01, U5-04). Parameter b5-38 determines the display value when the maximum frequency is output and parameter b5-39 determines the number of digits. The setting value is equal to the number of decimal places. No. Name Setting Range b5-38 PID Setpoint User Display 1 to 60000 b5-39 PID Setpoint Display Digits 0 to 3 Default Determined by b5-20 Determined by b5-20 n C1-01 to C1-04: Accel, Decel Times 1 and 2 Two different sets of acceleration and deceleration times can be set in the drive by digital inputs, motor selection, or switched automatically. Acceleration time parameters always set the time to accelerate from 0 Hz to the maximum output frequency (E1-04). Deceleration time parameters always set the time to decelerate from maximum output frequency to 0 Hz. C1-01 and C1-02 are the default active accel/decel settings. No. C1-01 C1-02 C1-03 C1-04 Parameter Name Acceleration Time 1 Deceleration Time 1 Acceleration Time 2 Deceleration Time 2 Setting Range Default 20.0 s 0.0 to 6000.0 s <1> 10.0 s <1> The setting range for the acceleration and deceleration times is determined by the accel/decel time setting units in C1-10. For example, if the time is set in units of 0.01 s (C1-10 = 0), the setting range becomes 0.00 to 600.00 s. Switching Acceleration Times by Digital Input Accel/decel time 1 is active by default if no input is set. Activate accel/decel times 2, 3, and 4 by digital inputs (H1-oo = 7 and 1A) as explained in Table 4.19. Table 4.19 Accel/Decel Time Selection by Digital Input Accel/Decel Time Sel. 2 H1-oo = 1A 0 1 0 0 Active Times Acceleration C1-01 C1-03 Deceleration C1-02 C1-04 Figure 4.33 shows an operation example for changing accel/decel. times. The example below requires that the stopping method be set for “Ramp to stop” (b1-03 = 0). Output frequency Accel Time 1 (C1-01) Decel Time 1 Decel Time 2 (C1-02) Accel Time 2 (C1-04) (C1-03) Decel Time 1 (C1-02) 4 Time FWD (REV) Run command ON OFF Accel/Decel Time Selection 1 (Terminals S1 to S8, H1- oo = “7”) ON ON OFF Figure 4.33 Timing Diagram of Accel/Decel Time Change n E2-01: Motor Rated Current Provides motor control, protects the motor, and calculates torque limits. Set E2-01 to the full load amps (FLA) stamped on the motor nameplate. If Auto-Tuning completes successfully, the value entered to T1-04 will automatically be saved to E2-01. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Start-Up Programming & Operation Accel/Decel Time Sel. 1 H1-oo = 7 157 4.6 Basic iQpump Setup and Application Preset Parameters No. Parameter Name E2-01 Motor Rated Current Note: Setting Range 10% to 200% of the drive rated current Default Determined by o2-04 1. The number of decimal places in the parameter value depends on the drive model. This value has two decimal places (0.01 A) if the drive is set for a maximum applicable motor capacity up to and including 11 kW, and one decimal place (0.1 A) if the maximum applicable motor capacity is higher than 11 kW. Refer to Power Ratings on page 234 for details. 2. An oPE02 error will occur if the motor rated current in E2-01 is set lower than the motor no-load current in E2-03. Set E2-03 correctly to prevent this error. n E2-04: Number of Motor Poles Set the number of motor poles to E2-04. If Auto-Tuning completes successfully, the value entered to T1-06 will automatically be saved to E2-04. No. E2-04 Parameter Name Number of Motor Poles Setting Range 2 to 48 Default 2 n H1-01 to H1-08: Functions for Terminals S1 to S8 These parameters assign functions to the multi-function digital inputs. The various functions and settings are listed in Table 4.20. No. Setting Range Parameter Name Default H1-01 Multi-Function Digital Input Terminal S1 Function Selection 1 to 9F H1-02 H1-03 H1-04 Multi-Function Digital Input Terminal S2 Function Selection Multi-Function Digital Input Terminal S3 Function Selection Multi-Function Digital Input Terminal S4 Function Selection 1 to 9F 0 to 9F 0 to 9F 40 (F) <1> : Forward Run Command (2-Wire sequence) F: Through Mode 26: External Pump Fault 14: Fault Reset H1-05 Multi-Function Digital Input Terminal S5 Function Selection 0 to 9F 8D (0) <1> : Multi Setpoint 1 H1-06 Multi-Function Digital Input Terminal S6 Function Selection 0 to 9F 80 (3) <1> : HAND Mode H1-07 Multi-Function Digital Input Terminal S7 Function Selection 0 to 9F 81 (4) <1> : HAND Mode 2 H1-08 Multi-Function Digital Input Terminal S8 Function Selection 0 to 9F F (6) <1> : Through Mode <1> Number appearing in parenthesis is the default value after performing a 3-Wire initialization (A1-03 = 3330). Table 4.20 Multi-Function Digital Input Terminal Settings Setting 0 3 4 5 6 7 8 9 A B C F 10 11 12 13 14 15 17 18 19 158 Function 3-Wire sequence Multi-Step Speed Reference 1 Multi-Step Speed Reference 2 Multi-Step Speed Reference 3 Jog reference selection Accel/decel time selection 1 Baseblock command (N.O.) Baseblock command (N.C.) Accel/decel ramp hold Drive overheat alarm (oH2) Analog terminal input selection Through mode Up command Down command Forward Jog Reverse Jog Fault reset Fast Stop (N.O.) Fast Stop (N.C.) Timer function input PID disable Page – – – – – – – – – – – – – – – – – – – – – Setting 1A 1B 1E 20 to 2F 30 31 32 34 35 40 41 42 43 47 51 52 60 Function Accel/decel time selection 2 Program lockout Reference sample hold Ext. pump fault PID integral reset PID integral hold Multi-Step Speed Reference 4 PID soft starter cancel PID input level selection Forward run command (2-Wire sequence) Reverse run command (2-Wire sequence) Run command (2-Wire sequence 2) FWD/REV command (2-Wire sequence 2) Node setup Sequence Timer Disable Sequence Timer Cancel DC Injection Braking command Page – – – – – – – – – – – – – – – – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters Setting 63 65 66 67 68 6A 73 75 76 7A 7B Function External Speed Search command 1 External Speed Search command 2 Field weakening KEB Ride-Thru 1 (N.C.) KEB Ride-Thru 1 (N.O.) Communications test mode High Slip Braking (HSB) Drive enable Low City Press Up 2 command Down 2 command KEB Ride-Thru 2 (N.C.) KEB Ride-Thru 2 (N.O.) 80 81 88 HAND Mode HAND Mode 2 Volute-Thermostat Normally Open 61 62 Page – – – – – – – – – – – – – Setting 89 8C 8D 8E 8F 90 92 95 A8 A9 AA AB AC AD AF B0 – – Function Volute-Thermostat Normally Closed Disable Pre-Charge Multi Setpoint 1 Multi Setpoint 2 Low Water Level High Water Level Reset Accum Remove Drive Disable Secondary PI Disable (N.O.) Secondary PI Disable (N.C.) Secondary PI Inverse Operation Secondary PI Integral Reset Secondary PI Integral Hold Select Secondary PI Parameters Emergency Override Forward Run Emergency Override Reverse Run Page – – – – – – – – – – – – – – – n H2-01 to H2-03: Terminal M1-M2, M3-M4, and MD-ME-MF Function Selection The drive has three multi-function output terminals. Table 4.21 lists the functions available for theses terminals using H2-01, H2-02, and H2-03. No. H2-01 H2-02 H2-03 Parameter Name Terminal M1-M2 Function Selection (relay) Terminal M3-M4 Function Selection (relay) Terminal MD-ME-MF Function Selection (relay) Setting Range 0 to 192 0 to 192 0 to 192 Default 37: During Frequency Output F: Through Mode E: Fault Table 4.21 Multi-Function Digital Output Terminal Settings Function During run Zero speed Speed agree 1 User-set speed agree 1 Frequency detection 1 Frequency detection 2 Drive ready DC bus undervoltage During baseblock (N.O.) Frequency reference source Run command source Torque detection 1 (N.O.) Frequency reference loss Braking resistor fault Fault Through mode Minor fault Fault reset command active Timer output Speed agree 2 User-set speed agree 2 Frequency detection 3 Frequency detection 4 Page – – – – – – – – – – – – – – – – – – – – – – – Setting 17 18 19 1A 1B 1E 1F 20 22 2F 30 37 38 39 3C 3D 3E 3F 4A 4C 4D 4E 4F YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Function Torque detection 1 (N.C.) Torque detection 2 (N.O.) Torque detection 2 (N.C.) During reverse During baseblock (N.C.) Restart enabled Motor overload alarm (oL1) Drive overheat pre-alarm (oH) Mechanical weakening detection Maintenance period During torque limit During frequency output Drive enabled Watt hour pulse output LOCAL/REMOTE status During speed search PID feedback low PID feedback high During KEB Ride-Thru During fast stop oH Pre-alarm time limit Braking transistor fault (rr) Braking resistor overheat (oH) Page – – – – – – – – – – – – – – – – – – – – – – Start-Up Programming & Operation Setting 0 1 2 3 4 5 6 7 8 9 A B C D E F 10 11 12 13 14 15 16 4 159 4.6 Basic iQpump Setup and Application Preset Parameters Setting 50 51 52 53 54 58 60 71 72 73 80 81 82 83 84 89 8B Function Waiting to Run Sequence timer 1 Page – Setting 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D A2 – SeqTimer Disable Sequence timer 2 – SeqTimer Cancel Sequence timer 3 – Sequence timer 3 Sequence timer 4 – Sequence Timer 4 Underload detection – UL6 Internal cooling fan alarm Secondary PI Feedback Low PI2 Feedback Low Secondary PI Feedback High – – PI2 FeedbackHigh – Low City Press Pump 2 Control Pump 3 Control Pump 4 Control Pump 5 Control Pump 6 Control Output 1 Limit Lube Pump – – – – – – – – A3 A4 A5 A9 AA 100 to 1AA Function Pump Fault Transducer Loss Setptoint Not Met Loss of Prime Volute Thermostat Fault High Feedback Low Feedback Low Flow Accum Level High Flow Low Water Level Low Suction High Suction Sleep Active Page – – – – – – – – – – – – – Start Delay Pre-Charge Anti-Jam Active Thrust Mode Utility Start Delay – – – – – Function 0 to AA with inverse output – Setting 30: During Torque Limit The output closes when the motor is operating at the torque limit specified by the L7-oo parameters or an analog input. This setting can only be used in OLV control mode. n H3-01: Terminal A1 Signal Level Selection Selects the input signal level for analog input A1. No. H3-01 Name Terminal A1 Signal Level Selection Setting Range 0 to 3 Default 0 Setting 0: 0 to 10 Vdc The input level is 0 to 10 Vdc. The minimum input level is limited to 0%, so that a negative input signal due to gain and bias settings will be read as 0%. Setting 1: 0 to 10 Vdc Bipolar The input level is -10 to 10 Vdc. If the resulting voltage is negative after being adjusted by gain and bias settings, then the motor will rotate in reverse. Setting 2: 4 to 20 mA Setting 3: 0 to 20 mA n H3-02: Terminal A1 Function Selection Selects the input signal level for analog input A3. No. H3-02 Name Terminal A1 Function Selection Setting Range 0 to 32 Default 0 n H3-03, H3-04: Terminal A1 Gain and Bias Settings Parameter H3-03 sets the level of the selected input value that is equal to 10 Vdc input at terminal A1 (gain). Parameter H3-04 sets the level of the selected input value that is equal to 0 V input at terminal A1 (bias). Use both parameters to adjust the characteristics of the analog input signal to terminal A1. 160 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters No. H3-03 H3-04 Name Terminal A1 Gain Setting Terminal A1 Bias Setting Setting Range -999.9 to 999.9% -999.9 to 999.9% Default 100.0% 0.0% Setting Examples • Gain H3-03 = 200%, bias H3-04 = 0, terminal A1 as frequency reference input (H3-02 = 0): A 10 Vdc input is equivalent to a 200% frequency reference and 5 Vdc is equivalent to a 100% frequency reference. Since the drive output is limited by the maximum frequency parameter (E1-04), the frequency reference will be equal to E1-04 above 5 Vdc. H3-01 = 0 H3-01 = 1 Gain = 200 % Gain = 200 % Frequency reference 100% E1-04 -10 V 100 % E1-04 -5 V 0V 5V 10 V -100% E1-04 Bias = 0 % Gain = -200 % 0V 5V 10 V Figure 4.34 Frequency Reference Setting by Analog Input with Increased Gain • Gain H3-03 = 100%, bias H3-04 = -25%, terminal A1 as frequency reference input: An input of 0 Vdc will be equivalent to a -25% frequency reference. When parameter H3-01 = 0, the frequency reference is 0% between 0 and 2 Vdc input. When parameter H3-01 = 1, the motor will rotate in reverse between -10 and 2 Vdc input. H3-01 = 0 100 % Frequency reference H3-01 = 1 100% H3-01 = 0 -10 V -6.0 V 2.0 V -25% 2.0 V -25% 10 V Analog Input Voltage H3-01 = 1 -100% E1-04 Start-Up Programming & Operation 0 10 V Analog Input Voltage -150% Figure 4.35 Frequency Reference Setting by Analog Input with Negative Bias n H3-05: Terminal A3 Signal Level Selection Determines the function assigned to analog input terminal A3. No. H3-05 Name Terminal A3 Signal Level Selection Setting Range 0 to 3 4 Default 0 Setting 0: 0 to 10 Vdc The input level is 0 to 10 Vdc. See the explanation provided for H3-01. Refer to Setting 0: 0 to 10 Vdc on page 160. Setting 1: 0 to 10 Vdc Bipolar The input level is -10 to 10 Vdc. See the explanation provided for H3-01. Refer to Setting 1: 0 to 10 Vdc Bipolar on page 160. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 161 4.6 Basic iQpump Setup and Application Preset Parameters Setting 2: 4 to 20 mA Setting 3: 0 to 20 mA n H3-06: Terminal A3 Function Selection Determines the function assigned to analog input terminal A3. No. H3-06 Name Terminal A3 Function Selection Setting Range 0 to 31 Default 20 n H3-07, H3-08: Terminal A3 Gain and Bias Setting Parameter H3-07 sets the level of the selected input value that is equal to 10 Vdc input at terminal A3 (gain). Parameter H3-08 sets the level of the selected input value that is equal to 0 V input at terminal A3 (bias). No. H3-07 H3-08 Name Terminal A3 Gain Setting Terminal A3 Bias Setting Setting Range -999.9 to 999.9% -999.9 to 999.9% Default 100.0% 0.0% n H3-09: Terminal A2 Signal Level Selection Selects the input signal level for analog input A2. Set Jumper S1 on the terminal board accordingly for a voltage input or current input. No. H3-09 Name Terminal A2 Signal Level Selection Setting Range 0 to 3 Default 2 Setting 0: 0 to 10 Vdc The input level is 0 to 10 Vdc. Refer to Setting 0: 0 to 10 Vdc on page 160. Setting 1: 0 to 10 Vdc Bipolar The input level is -10 to 10 Vdc. Refer to Setting 1: 0 to 10 Vdc Bipolar on page 160. Setting 2: 4 to 20 mA The input level is 4 to 20 mA. Negative input values by negative bias or gain settings will be limited to 0%. Setting 3: 0 to 20 mA The input level is 0 to 20 mA. Negative input values by negative bias or gain settings will be limited to 0%. n H3-10: Terminal A2 Function Selection Determines the function assigned to analog input terminal A2. No. H3-10 Name Terminal A2 Function Selection Setting Range 0 to 32 Default B n H3-11, H3-12: Terminal A2 Gain and Bias Setting Parameter H3-11 sets the level of the input value selected that is equal to 10 Vdc input or 20 mA input to terminal A2. Parameter H3-12 sets the level of the input value selected that is equal to 0 V, 4 mA or 0 mA input at terminal A2. Use both parameters to adjust the characteristics of the analog input signal to terminal A2. The setting works in the same way as parameters H3-03 and H3-04 for analog input A1. No. H3-11 H3-12 Name Terminal A2 Gain Setting Terminal A2 Bias Setting Setting Range -999.9 to 999.9% -999.9 to 999.9% Default 100.0% 0.0% n H4-01, H4-04: Multi-Function Analog Output Terminal FM, AM Monitor Selection Sets the desired drive monitor parameter Uo-oo to output as an analog value via terminal FM and AM. Refer to U1: Operation Status Monitors on page 326 for a list of all monitors. The “Analog Output Level” column indicates whether a monitor can be used for analog output. Example: Enter “103” for U1-03. 162 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters No. H4-01 H4-04 Name Multi-Function Analog Output Terminal FM Monitor Selection Multi-Function Analog Output Terminal AM Monitor Selection Setting Range 000 to 999 000 to 999 Default 102 103 A setting of 031 or 000 applies no drive monitor to the analog output. With this setting, terminal functions as well as FM and AM output levels can be set by a PLC via a communication option or MEMOBUS/Modbus (through mode). n H4-02, H4-03: Multi-Function Analog Output Terminal FM Gain and Bias H4-05, H4-06: Multi-Function Analog Output Terminal AM Gain and Bias Parameters H4-02 and H4-05 set the terminal FM and AM output signal level when the value of the selected monitor is at 100%. Parameters H4-03 and H4-06 set the terminal FM and AM output signal level when the value of the selected monitor is at 0%. Both are set as a percentage, where 100% equals 10 Vdc or 20 mA analog output and 0% equals 0 V or 4 mA. The output voltage of both terminals is limited to +/-10 Vdc. The output signal range can be selected between 0 to +10 Vdc or -10 to +10 Vdc, or 4 to 20 mA using parameter H4-07 and H4-08. Figure 4.36 illustrates how gain and bias settings work. No. H4-02 H4-03 H4-05 H4-06 Name Multi-Function Analog Output Terminal FM Gain Multi-Function Analog Output Terminal FM Bias Multi-Function Analog Output Terminal AM Gain Multi-Function Analog Output Terminal AM Bias Setting Range -999.9 to 999.9% -999.9 to 999.9% -999.9 to 999.9% -999.9 to 999.9% Default 100.0% 0.0% 50.0% 0.0% Using Gain and Bias to Adjust Output Signal Level The output signal is adjustable while the drive is stopped. Terminal AM 1. View the value set to H4-05 (Terminal AM Monitor Gain) on the digital operator. A voltage equal to 100% of the parameter being set in H4-04 will be output from terminal AM. 2. Adjust H4-05 viewing the monitor connected to the terminal AM. 3. View the value set to H4-06 on the digital operator; terminal AM will output a voltage equal to 0% of the parameter being set in H4-04. 4. Adjust H4-06 viewing the output signal on the terminal AM. H4-07, 08 = 0 H4-07, 08 = 1 15 V Gain = 150% Bias = 0% Output Voltage 10 V 10 V Output Voltage Gain 150% Bias 0% 5V Gain 100% Bias 0% Gain 50% Bias 0% Gain = 100% Bias = 0% Gain = 50% Bias = 0% 5V -100% -5 V 4 100% Monitor Value -10 V 0V 0% Monitor Value 100% -15 V Figure 4.36 Analog Output Gain and Bias Setting Example 1 and 2 Set H4-03 to 30% for an output signal of 3 V at terminal FM when the monitored value is at 0%. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Start-Up Programming & Operation Terminal FM 1. View the value set to H4-02 (Terminal FM Monitor Gain) on the digital operator. A voltage equal to 100% of the parameter being set in H4-01 will be output from terminal FM. 2. Adjust H4-02 viewing the monitor connected to the terminal FM. 3. View the value set to H4-03 on the digital operator; terminal FM will output a voltage equal to 0% of the parameter being set in H4-01. 4. Adjust H4-03 viewing the output signal on the terminal FM. 163 4.6 Basic iQpump Setup and Application Preset Parameters H4-07, 08 = 0 Gain = 100% Bias = 30% H4-07, 08 = 1 10V 10 V Gain = 100% Bias = 0% Output Voltage Bias 30% Gain 100% Output Voltage 3V -100% Bias 0% Gain 100% 3V -4 V 0V 100% Monitor Value -10 V 0% Monitor Value 100% Figure 4.37 Analog Output Gain and Bias Setting Example 3 n H4-07, H4-08: Multi-Function Analog Output Terminal FM, AM Signal Level Selection Sets the voltage output level of U parameter (monitor parameter) data to terminal FM and terminal AM using parameters H4-07 and H4-08. No. H4-07 H4-08 Name Multi-Function Analog Output Terminal FM Signal Level Selection Multi-Function Analog Output Terminal AM Signal Level Selection Setting Range Default 0 to 2 0 0 to 2 0 Setting 0: 0 to 10 V Setting 1: -10 V to 10 V Setting 2: 4 to 20 mA n L5-01: Number of Auto Restart Attempts Sets the number of times that the drive may attempt to restart itself. When the counter reaches the number set to L5-01, the operation stops and the fault must be manually cleared and reset. The restart counter is incremented at each restart attempt, regardless of whether the attempt was successful. When the counter reaches the number set to L5-01, the operation stops and the fault must be manually cleared and reset. The number of fault restarts is reset to zero when: • The drive operates normally for 10 minutes following a fault restart. • A fault is cleared manually after protective functions are triggered. • The power supply is cycled. No. L5-01 Name Number of Auto Restart Attempts Setting Range 0 to 10 Times Default 5 Times n L5-04: Fault Reset Interval Time Determines the amount of time to wait between restart attempts when parameter L5-05 is set to 1. No. L5-04 Name Fault Reset Interval Time Setting Range 0.5 to 600.0 s Default 10.0 s n o1-08: Third Line User Monitor Selection Selects the monitor that is shown in the third line. Effective only when o1-06 is set to 1. Enter the last three digits of the monitor parameter number to be displayed: Uo-oo. For example, set “403” to display monitor parameter U4-03. No. o1-07 Name Second Line User Monitor Selection Setting Range 101 to 799 Default 103 n P1-01: Pump Mode Selects the base operation mode of the drive controller. 164 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters No. P1-01 Parameter Name Pump Mode Setting Range 0, 1, 3 Default 0 Setting 0: Drive only Designed for single pump stand-alone applications Setting 1: Contactor lag Contactor Lag systems multiplex a main pump with up to 5 lag pumps. The drive will stage and de-stage the lag pumps based on system demand by using its digital output contacts to control the lag pump motor starters Setting 3: MEMOBUS network Up to eight drives can be networked together as a coordinated system to provide for system redundancy and precise control. n P1-02: System Units Selects the base unit in which most drive PID setpoints, scaling, monitors, limits, and faults/alarm levels will be set. Note: No. P1-02 Set this parameter prior to changing other parameters, as internal scaling is based on P1-02. Parameter Name System Units Setting Range 0 to 10; 25 Default 1 Setting 0: No unit Setting 1: PSI: Pounds per square inch Setting 2: Pa: Pascals Setting 3: Bar: Bar Setting 4: "WC: Inch of water Setting 5: "Hg: Inch of Mercury Setting 6: ft: feet Setting 7: m: meters Setting 8: °F: Degrees Fahrenheit Setting 9: °C: Degrees Celsius Setting 10: Percent Setting 25: Flow (Use P6-04) Sets the feedback device scaling used for the PID controller. This information can be found on the nameplate or specification sheet and is usually expressed as the maximum output of the device. For example, a pressure sensor scaling might be 145.0 PSI at 20 mA output and would require setting P1-03 to 145.0 PSI. Note: No. P1-03 Set this parameter prior to changing other parameters related to the PID feedback, as internal scaling is based on P1-03. Parameter Name Feedback Device Scaling Setting Range 0.1 to 6000.0 Default 145.0 PSI n P1-04: Start / Draw Down Level Sets the wake up level from the Sleep function. This setting is dependent on whether PID is normal or inverse acting (b5-09). When the drive is asleep and the PID feedback signal rises above (normal acting) or falls below (inverse acting) this setting for the time set in P1-05, Start Level Delay Time, the drive will wake up. No. P1-04 Parameter Name Start / Draw Down Level Setting Range -999.9 to 999.9 Default 0.0 n P1-05: Start Level Delay Time Sets the delay time for waking the drive to prevent accidental wake up caused by erratic feedback. No. P1-05 Parameter Name Start Level Delay Time YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Setting Range 0 to 3600 Default 1s 165 Start-Up Programming & Operation n P1-03: Feedback Device Scaling 4 4.6 Basic iQpump Setup and Application Preset Parameters n P1-06: Minimum Pump Speed Sets the minimum speed at which the drive will run the pump. Most pumps cannot run at low speeds due to cavitation, so be sure to consult the pump specification sheet for the minimum safe run speed. No. P1-06 Parameter Name Minimum Pump Speed Setting Range 0.0 to E1-04 Default 40.0 Hz n P1-08: Low Feedback Level Sets the level at which a Low Feedback alarm or fault will occur. When the PID feedback falls below the P1-08 setting for the time set in P1-09, the drive will respond based on the setting in P1-10. No. P1-08 Parameter Name Low Feedback Level Setting Range 0.0 to 6000.0 Default 0.0 PSI n P1-09: Low Feedback Level Fault Delay Time Sets the delay time after which a Low Feedback alarm or fault will occur. When the PID feedback falls below the P1-08 setting for the time set in P1-09, the drive will respond based on the setting in P1-10. No. P1-09 Parameter Name Low Feedback Level Fault Delay Time Setting Range 0 to 3600 Default 10 s n P1-10: Low Feedback Selection Selects the drive response to a Low Feedback condition. When the PID feedback falls below the P1-08 setting for the time set in P1-09, the drive will respond based on the setting in P1-10. No. P1-10 Parameter Name Low Feedback Selection Setting Range 0 to 2 Default 0 Setting 0: Fault Setting 1: Alarm Setting 2: Digital out only n P1-11: High Feedback Level Sets the level at which a High Feedback alarm or fault will occur. When the PID feedback rises above the P1-11 setting for the time set in P1-12, the drive will respond based on the setting in P1-13. No. P1-11 Parameter Name High Feedback Level Setting Range 0.0 to 6000.0 Default 155.0 PSI n P1-12: High Feedback Level Fault Delay Time Sets the delay time after which a Low Feedback alarm or fault will occur. When the PID feedback rises above the P1-11 setting for the time set in P1-12, the drive will respond based on the setting in P1-13. No. P1-12 Parameter Name High Feedback Level Fault Delay Time Setting Range 0 to 3600 Default 5s n P1-13: High Feedback Selection Selects the drive response to a High Feedback condition. When the PID feedback rises above the P1-11 setting for the time set in P1-12, the drive will respond based on the setting in P1-13. No. P1-13 166 Parameter Name High Feedback Selection Setting Range 0 to 2 Default 0 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters Setting 0: Fault Setting 1: Alarm Setting 2: Digital out only n P2-01: Sleep Level Type Selects which data source the drive will use to determine if it should activate the sleep function. This parameter is applicationdependent and should be set in conjunction with the type of system data is available. Choose the data type that best represents a low-activity condition for the system. Note: Set this parameter prior to changing other parameters related to the Sleep Function, as internal scaling is based on P2-01. No. P2-01 Parameter Name Sleep Level Type Setting Range 0 to 4 Default 0 Setting 0: Output frequency Setting 1: Output current Setting 2: Feedback Setting 3: Output speed (RPM) Setting 4: Flow meter (requires flow meter) n P2-02: Sleep Level Sets the level at which the drive will enter sleep mode. The drive will enter sleep mode when the monitored data falls below the P2-02 setting for the time set in P2-03. No. P2-02 Parameter Name Sleep Level Setting Range 0.0 to 6000.0 Default 0.0 Hz n P2-03: Sleep Delay Time Sets the delay time after which the drive will enter sleep mode. The drive will enter sleep mode when the monitored data falls below the P2-02 setting for the time set in P2-03. No. P2-03 Parameter Name Sleep Delay Time Setting Range 0 to 3600 Default 0s n P3-00: Number of Lag Pumps No. P3-00 Parameter Name Number of Lag Pumps Setting Range 1 to 5 Default 1 n P3-50: Pump 2 Frequency Shutdown Level Sets the level at which the first lag pump (2nd pump in the system) will shut down or de-stage. This parameter is effective when the P3-01 is set to 0 or 2 (pump staging is based on output frequency). When the output frequency falls below the P3-50 leel for the time set in P3-09, the pump will be de-staged. No. P3-50 Parameter Name Pump 2 Frequency Shutdown Level Setting Range 0.0 to 400.0 Default 40.0 Hz n P3-60: Pump 3 Frequency Shutdown Level Sets the level at which the second lag pump (3rd pump in the system) will shut down or de-stage. This parameter is effective when the P3-01 is set to 0 or 2 (pump staging is based on output frequency). When the output frequency falls below the P3-50 leel for the time set in P3-09, the pump will be de-staged. No. P3-60 Parameter Name Pump 3 Frequency Shutdown Level YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Setting Range 0.0 to 400.0 Default 40.0 Hz 167 Start-Up Programming & Operation Sets the number of lag pumps in the system. When using Contactor Multiplexing for the control lag pumps, first set P1-01 to 1. Then select the number of lag pumps to be controlled in P3-00. Set the corresponding multi-function digital outputs for lag pumps (H2-oo = 80-82 and F5-oo = 83-84). The methods used to determine lag pump staging and de-staging order are selected in P1-30 and P1-31. 4 4.6 Basic iQpump Setup and Application Preset Parameters n P3-70: Pump 4 Frequency Shutdown Level Sets the level at which the third lag pump (4th pump in the system) will shut down or de-stage. This parameter is effective when the P3-01 is set to 0 or 2 (pump staging is based on output frequency). When the output frequency falls below the P3-50 leel for the time set in P3-09, the pump will be de-staged. No. P3-40 Parameter Name Pump 4 Frequency Shutdown Level Setting Range 0.0 to 400.0 Default 40.0 Hz n P4-01: Pre-Charge Level Sets the level at which the drive will activate the pre-charge function. At start, if the PID is below the P4-01 setting, the drive will run at the P4-02 frequency setting for the time set in P4-03. PID control is delayed until the Pre-charge function stops. The drive will exit the pre-charge function early if the feedback rises above the P4-01 setting or if a Low Water digital input switch (H1-oo = 8F) deactivates. Pre-charge is useful to slowly fill or pressurize a system. No. P4-01 Parameter Name Pre-Charge Level Setting Range 0.0 to 6000.0 Default 0.0 PSI Setting Range 0.0 to E1-04 Default 0.0 Hz Setting Range 0.0 to 3600.0 Default 0.0 min n P4-02: Pre-Charge Frequency Sets the frequency at which the pre-charge function will run. No. P4-02 Parameter Name Pre-Charge Frequency n P4-03: Pre-Charge Time Sets the duration of time that the Pre-Charge function will run. No. P4-03 Parameter Name Pre-Charge Time n P4-10: AUTO Mode Operator Run Power Down Storage Selects drive response to power loss with regards to the Run command. When running in AUTO Mode and using a Run command from the keypad (b1-02 = 0), P4-10 determines whether the drive will automatically start running when power is reapplied. The factory setting of this parameter requires pressing the AUTO key to start the drive after power loss. WARNING! Sudden Movement Hazard. If the drive is running at power loss, it will automatically initiate an internal Run command upon power-up if P4-10 = 1 (Enabled) and could result in death or serious injury from moving equipment. No. P4-10 Parameter Name AUTO Mode Operator Run Power Down Storage Setting Range 0, 1 Default 0 Setting 0: Disabled Setting 1: Enabled n P4-12: Thrust Bearing Frequency Sets the frequency used by the drive when determining which acceleration and deceleration time to use. The Thrust Bearing function is used for applications using submersible motors. The function provides an alternate acceleration time (P4-11) and deceleration time (P4-13) for protecting the pump bearings. At start, the drive will use the P4-11 acceleration time until the P4-12 frequency is reached, at which time it will use the active C1-oo acceleration and deceleration times. At stop, if the output frequency is above the P4-12 setting, the active C1-oo deceleration time will be used until the P4-12 setting is reached at which time it will use the P4-13 time setting for the rest of deceleration. If P4-12 is set greater than P1-06 (minimum Pump Speed), P4-12 will become the frequency lower limit. The drive PID control must be disabled (b5-01 = 0) for this function to work. No. P4-12 Parameter Name Thrust Bearing Frequency Setting Range 0.0 to E1-04 Default 30.0 Hz n P4-17: Utility Start Delay Set the delay time after power up until the drive will recognize a Run command present within one second of power up. 168 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.6 Basic iQpump Setup and Application Preset Parameters This is useful in preventing a peak power surge when multiple drives power up and begin accelerating simultaneously. This function works when the drives all have different P4-17 settings to spread out the power draw during acceleration. No. P4-17 Parameter Name Utility Start Delay Setting Range 0.0 to 1000.0 Default 0.2 min n P5-02: HAND Reference 1 Sets the frequency reference of HAND mode. When the drive is stopped, pressing the HAND key will start the drive and the drive will accelerate to the P5-02 setting. No. P5-02 Parameter Name HAND Reference 1 Setting Range 0.0 to E1-04 Default 40.0 Hz n P5-04: HAND Key Function Selection Selects whether the HAND key on the HOA keypad is active. Disabling this function by setting P5-04 to 0 will prevent the drive from entering HAND Mode. No. P5-04 Parameter Name HAND Key Function Selection Setting Range 0, 1 Default 1 Setting 0: Disabled Setting 1: Enabled n Q1-01: PID Controller Setpoint 1 Sets the PID setpoint for the controller. The drive will use the system feedback signal and modulate the pump speed to regulate the feedback at the Q1-01 setpoint. The units for Q1-01 are selected by b1-01 and the scaling is set in parameter P1-03. This parameter is active when b1-01 (Reference Source) is set to 0 (HOA keypad). No. Q1-01 Parameter Name PID Controller Setpoint 1 Setting Range 0.0 to 6000.0 Default 0.0 Sets the Suction Pressure setpoint. The units of Q5-03 are selected in Q5-01 and the scaling is set in Q5-02 (Suction Transducer Scaling). The Suction Pressure function is enabled by setting Q5-01 = 1 (Suction Pressure). This function uses Q5-03 as the setpoint instead of Q1-01, and Q5-02 as the feedback scaling instead of P1-02. Set b5-01 to a value other than 0 to enable the drive PID controller and use this function. This feature can be used to allow the drive to control (outlet) pressure when there is adequate pressure on the inlet side of the pump by setting Q5-01 to 1 (Suction Pressure). When the suction pressure (pump inlet pressure) drops to the Suction Pressure Setpoint (Q5-03), it will regulate the suction pressure and the outlet pressure will be allowed to drop. This requires both a suction pressure transducer on the pump inlet and a pressure feedback transducer on the pump output. No. Q5-03 Parameter Name Suction Pressure Setpoint Setting Range 0.0 to 1200.0 Default 20.0 n Q5-06: Wake-Up Suction Pressure Sets the wake up level for the suction pressure control function. The drive falls asleep based on the Q5-04 level and Q5-05 delay time. The drive will wake up when the suction pressure feedback rises above the Q5-06 setting for the time set in Q5-07 AND the standard sleep function calls for a wake up (P1-04 and P1-05). No. Q5-06 Parameter Name Wake-Up Suction Pressure Setting Range 0.0 to 1200.0 Default 30.0 n Q5-09: Low Suction Pressure Detection Level Sets the level at which a Low Suction Pressure alarm or fault will occur. When the suction pressure feedback falls below the Q5-09 setting for the time set in Q5-10, the drive will respond based on the setting in Q5-11. No. Q5-09 Parameter Name Low Suction Pressure Detection Level YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Setting Range 0.0 to 1200.0 Default 0.0 169 Start-Up Programming & Operation n Q5-03: Suction Pressure Setpoint 4 4.6 Basic iQpump Setup and Application Preset Parameters n Q5-10: Low Suction Pressure Detection Time Sets the delay time after which a Low Suction Pressure alarm or fault will occur. When the suction pressure feedback falls below the Q5-09 setting for the time set in Q5-10, the drive will respond based on the setting in Q5-11. No. Q5-10 Parameter Name Low Suction Pressure Detection Time Setting Range 0.0 to 300.0 Default 0.1 n Q5-11: Low Suction Pressure Behavior Select Selects the drive response to a Low Suction Pressure condition. When the suction pressure feedback falls below the Q5-09 setting for the time set in Q5-10, the drive will respond based on the setting in Q5-11. By setting Q5-11 to 3 (Restart Q5-15), the drive will attempt to reset itself for the number of times set in L5-01 waiting for the Q5-15 reset time before each reset attempt. The drive will fault if the L5-01 attempts are exceeded. No. Q5-11 Parameter Name Low Suction Pressure Behavior Select Setting Range 0 to 3 Default 1 Setting 0: No display (digital output only) Setting 1: Alarm only Setting 2: Fault Setting 3: Auto-restart (time set in Q5-15) n Q5-16: Suction Control Proportional Gain Sets the proportional gain of the Suction Pressure controller. Increasing this value will make the system more responsive but can lead to instability. Q5-16 is used in place of b5-02 for suction pressure control. No. Parameter Name Suction Control Proportional Gain Setting Range 0.00 to 25.00 Default 2.00 n Q5-17: Suction Control Integral Time Sets the integral time of the Suction Pressure controller. Decreasing this value will make the system more responsive but can lead to overshoot. Q5-17 is used in place of b5-03 for suction pressure control. No. 170 Parameter Name Suction Control Integral Time Setting Range 0.0 to 360.0 Default 5.0 s YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 4.7 Test Run with No Load 4.7 Test Run with No Load u No-Load Operation Test Run This section explains how to operate the drive with the motor decoupled from the load during a test run. n Before Starting the Motor Check the following items before operation: • Ensure the area around the motor is safe. • Ensure external emergency stop circuitry is working properly and other safety precautions have been taken. n During Operation Check the following items during operation: • The motor should rotate smoothly (i.e., no abnormal noise or oscillation). • The motor should accelerate and decelerate smoothly. n No-Load Operation Instructions The following example illustrates a test run procedure using the HOA keypad. 1. 2. Step Before starting the motor, set parameter d1-01, Frequency Reference, to 6 Hz. The Run command from AUTO mode must be OFF. Display/Result – – - MODE - DRV Rdy Freq Ref (AI) U1-01= 0.00Hz Turn on the power to the drive. The initial display appears. U1-02= 0.00Hz LSEQ U1-03= 0.00 A LREF JOG FWD ALM DIGITAL OPERATOR JVOP-183 - -DRIVEMODE DRV -RdyRdy Freq Ref (OPR) U1-01= 0.00Hz U1- 01=60.00Hz LSEQ ---------------- U1-02= 0.00Hz U1-03= A LREF U1-0.00 02=60.00Hz JOG FWD FWD/REV FWD/REV JOG FWD F1 3. Press HAND to give the drive a Run command from HAND mode. The HAND light will turn on and the motor will rotate at 6 Hz. F2 M M ESC HAND RESET ENTER ENTER AUTO OFF HAND HAND Off On 4. Start-Up Programming & Operation Motor Ensure the motor is rotating in the correct direction and that no faults or alarms occur. Forward 5. If there is no error in step 3, press to increase the frequency reference. Increase the frequency in increments of 10 Hz, verifying smooth operation at all speeds. For each frequency, check the drive output current using monitor U1-03. The current should be well below the motor rated current. – – 4 ALM DIGITAL OPERATOR JVOP-183 - -DRIVEMODE DRV -RdyRdy FREF Freq Ref(OPR) (OPR) U1-01= 60.00Hz 0.00Hz U1- 01=60.00Hz LSEQ ---------------- U1-02= 0.00Hz U1-03= 0.00 A LREF U1-0.00A 02=60.00Hz JOG FWD FWD/REV FWD/REV JOG FWD F1 6. The drive should operate normally. Press OFF and the motor coasts to stop. OFF F2 M to stop the motor. The HAND light is YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide M ESC RESET AUTO HAND ENTER OFF HAND HAND On Off 171 4.8 Test Run with Load Connected 4.8 Test Run with Load Connected u Test Run with the Load Connected After performing a no-load test run, connect the motor and proceed to run the motor and load together. n Precautions for Connected Machinery WARNING! Sudden Movement Hazard. Clear all personnel from the drive, motor, and machine area before applying power. System may start unexpectedly upon application of power, causing death or serious injury. WARNING! Sudden Movement Hazard. Always check the operation of any fast stop circuits after they are wired. Fast stop circuits are required to provide safe and quick shutdown of the drive. Prepare to initiate an emergency stop during the test run. Operating a drive with untested emergency circuits could result in death or serious injury. • The motor should come to a complete stop without problems. • Connect the load and machinery to the motor. • Fasten all installation screws properly and check that the motor and connected machinery are held in place. n Checklist Before Operation • The motor should rotate in the proper direction. • The motor should accelerate and decelerate smoothly. n Operating the Motor under Loaded Conditions Test run the application similarly to the no-load test procedure when connecting the machinery to the motor. • Monitor U1-03 for overcurrent during operation. • If the application permits running the load in the reverse direction, change the motor direction and the frequency reference while watching for abnormal motor oscillation or vibration. • Correct any problems that occur with hunting, oscillation, and other control-related issues. 172 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5 Troubleshooting This chapter provides descriptions of the drive faults, alarms, errors, and messages. Guidance information for troubleshooting is also included. This chapter can also serve as a reference guide for tuning the drive during a trial run. 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 DRIVE ALARMS, FAULTS, ERRORS, AND MESSAGES..................................174 FAULT DETECTION.............................................................................................175 ALARM DETECTION...........................................................................................193 OPERATOR PROGRAMMING ERRORS............................................................203 AUTO-TUNING FAULT DETECTION..................................................................207 COPY FUNCTION RELATED DISPLAYS...........................................................211 HOA KEYPAD DISPLAY MESSAGES................................................................213 AUTO-TUNING.....................................................................................................215 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 173 5.1 Drive Alarms, Faults, Errors, and Messages 5.1 Drive Alarms, Faults, Errors, and Messages u Types of Alarms, Faults, and Errors Check the HOA keypad for information about possible faults if the drive or motor fails to operate. Refer to Using the HOA Keypad on page 111. If problems occur that are not covered in this manual, contact the nearest Yaskawa representative with the following information: • Drive model • Software version • Date of purchase • Description of the problem • List of modified parameters. Table 5.1 contains descriptions of the various types of alarms, faults, and errors that may occur while operating the drive. Table 5.1 Types of Alarms, Faults, and Errors Type Faults Minor Faults and Alarms Operation Errors Tuning Errors Copy Function Errors Drive LCD Display Messages 174 Drive Response When the drive detects a fault: • The HOA keypad displays text indicating the specific fault and the ALM indicator LED remains lit until the fault is reset. • The fault interrupts drive output and the motor coasts to a stop. • Some faults allow the user to select the stopping method when the fault occurs. • Fault output terminals MA-MC will close, and MB-MC will open. The drive will remain inoperable until the fault is cleared. Refer to Fault Reset Methods on page 213. When the drive detects an alarm or a minor fault: • The HOA keypad displays text indicating the specific alarm or minor fault, and the ALM indicator LED flashes. • The drive continues running the motor, although some alarms allow the user to select a stopping method when the alarm occurs. • A multi-function contact output set to be tripped by a minor fault (H2- oo = 10) closes. If the output is set to be tripped by an alarm, the contact will not close. • The HOA keypad displays text indicating a specific alarm and the ALM indicator LED flashes. Remove the cause of the problem to reset a minor fault or alarm. An operation error occurs when parameter settings conflict or do not match hardware settings (such as with an option card). When the drive detects an operation error: • The HOA keypad displays text indicating the specific error. • Multi-function contact outputs do not operate. The drive will not operate the motor until the error has been reset. Correct the settings that caused the operation error to clear the error. Tuning errors occur while performing Auto-Tuning. When the drive detects a tuning error: • The HOA keypad displays text indicating the specific error. • Multi-function contact outputs do not operate. • Motor coasts to stop. Remove the cause of the error and repeat the Auto-Tuning process. Copy Function Errors occur when using the HOA keypad or the USB Copy Unit to copy, read, or verify parameter settings. • The HOA keypad displays text indicating the specific error. • Multi-function contact outputs do not operate. Pressing any key on the HOA keypad will clear the fault. Investigate the cause of the problem (such as model incompatibility) and try again. The drive will display messages on the LCD display to indicate temporary drive statuses during normal pump operation. Messages do not require any action from the user and will clear from the LCD display automatically. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.2 Fault Detection 5.2 Fault Detection u Fault Displays, Causes, and Possible Solutions Faults are detected for drive protection, and cause the drive to stop while triggering the fault output terminal MA-MB-MC. Remove the cause of the fault and manually clear the fault before attempting to run the drive again. Table 5.2 Detailed Fault Displays, Causes, and Possible Solutions HOA Keypad Display ACCUM Accum Level Cause The accumulated level has exceeded the values set in P6-11 to P6-14. This is only effective when P1-15, Accumulated Behavior is set to 2 (fault with manual monitor reset) or 3 (fault with automatic monitor reset. HOA Keypad Display AJF Anti-Jam Fault Fault Name Accumulated Level Fault The total volume of water flow measured over time by the flow meter has exceeded the fault level setting. Possible Solution Set the Accumulated Level fault characteristics in P6-11 to P6-14 and P6-16. Drive response to this condition is controlled by P6-15, Accumulated Behavior. Auto-restart of this fault is controlled by P6-15, Accumulated Behavior and P6-05, Flow Accumulation Reset. Fault Name Anti-Jam Fault Cause Possible Solution The drive was not able to clear debris from the impeller in fewer than the number of • Check for proper pump operation. Remove debris from the pump impeller. attempts set in P7-02. This is only effective • Set the Anti-jam fault characteristics in P7-02 to P7-08. when P7-01, Anti-jam Operation is set to 1 • Drive response to this condition is controlled by P7-01, Anti-jam Operation Selection. (enabled). HOA Keypad Display Ana GeoTemp Lost Switched to Net Fault Name Analog Geothermal Temperature Lost Analog Geothermal Temperature has not been detected, and the Network Geothermal signal is now being used. Cause Possible Solution • Ensure that the Geothermal Temperature source is installed and working properly. If there is none present, • Defective or broken analog input source. set P9-60 to 3 so it will always read the Geothermal Temperature of another drive on the network . • H3-0o≠ 21 (Geothermal Temperature). • Set H3-0o = 21 (Geothermal Temperature) if the analog input source is to be used for Geothermal. Otherwise, set P9-02 to 3 if the drive does not have an analog Geothermal Temperature source. AnalogWL/SP Lost Switched to Net Fault Name Analog Water Level / Suction Pressure Lost Network Water Level / Suction Pressure is now being used because a wire-break was detected with the analog signal. Water Level Analog Input Wire Break (WL Wire Break) is effective when Q4-16 is set to 2 (Fault). Suction Pressure Analog Input Wire Break (SP Wire Break) is effective when Q5-19 is set to 2 (Fault). Possible Solution Cause • Defective or broken analog input source. • Confirm that the Water Level or Suction Pressure source is installed and working properly. • Wire-break detected with the Water • Confirm that the Q4-16 and Q5-19 settings are correct. Level / Suction Pressure analog signal • Set P9-50 to 3 if the drive does not have an analog input source. (H3-oo = 23). HOA Keypad Display bAT Cause The digital operator battery is low HOA Keypad Display boL Cause 5 Fault Name Digital Operator Battery Voltage Low Possible Solution Replace the digital operator battery. Fault Name Braking Transistor Overload Fault The braking transistor reached its overload level. Possible Solution YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Troubleshooting HOA Keypad Display 175 5.2 Fault Detection The wrong braking resistor is installed Select the correct braking resistor. HOA Keypad Display Fault Name Option Communication Error • The connection was lost after establishing initial communication. • Only detected when the run command frequency reference is assigned to an option card. Cause Possible Solution No signal was received from the PLC • Check for faulty wiring. • Correct the wiring. Faulty communications wiring or an existing short circuit • Check for disconnected cables and short circuits and repair as needed. • Check the various options available to minimize the effects of noise. • Counteract noise in the control circuit, main circuit, and ground wiring. Communication data error occurred due to • Ensure that other equipment such as switches or relays do not cause noise. Use surge absorbers if necessary. • Use only recommended cables or other shielded line. Ground the shield on the controller side or the drive noise input power side. • Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive power supply input. The option card is damaged Replace the option card if there are no problems with the wiring and the error continues to occur. The option card is not properly connected • The connector pins on the option card do not line up properly with the connector pins on the drive. to the drive • Reinstall the option card. bUS HOA Keypad Display Fault Name MEMOBUS/Modbus Communication Error CE Control data was not received for the CE detection time set to H5-09. Cause Possible Solution • Check for faulty wiring. Faulty communications wiring or an • Correct the wiring. existing short circuit • Check for disconnected cables and short circuits and repair as needed. • Check the various options available to minimize the effects of noise. • Counteract noise in the control circuit, main circuit, and ground wiring. • Use only recommended cables or other shielded line. Ground the shield on the controller side or the drive Communication data error occurred due to input power side. noise • Ensure that other equipment such as switches or relays do not cause noise. Use surge suppressors if required. • Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive power supply input. HOA Keypad Display CPF11 to CPF14 CPF16 to CPF19 Cause There is a self-diagnostic error in the control circuit Connector on the operator is damaged HOA Keypad Display CPF02 Cause Control circuit is damaged HOA Keypad Display CPF03 Cause 176 Fault Name Control Circuit Error Possible Solution • Cycle power to the drive. • If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. Replace the operator. Fault Name A/D Conversion Error An A/D conversion error or control circuit error occurred. Possible Solution • Cycle power to the drive. • If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. Fault Name Control Board Connection Error Connection error between the control board and the drive Possible Solution YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.2 Fault Detection • Turn off the power and check the connection between the control board and the drive. • If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. • Check the various options available to minimize the effects of noise. • Counteract noise in the control circuit, main circuit, and ground wiring. • Use only recommended cables or other shielded line. Ground the shield on the controller side or the drive Drive fails to operate properly due to noise input power side. interference • Ensure that other equipment such as switches or relays do not cause noise. Use surge suppressors if required. • Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive power supply input. There is a connection error HOA Keypad Display CPF06 Cause There is an error in EEPROM control circuit Fault Name EEPROM Memory Data Error Error in the data saved to EEPROM Possible Solution • Turn off the power and check the connection between the control board and the drive. • If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. The power supply was switched off while Reinitialize the drive (A1-03 = 2220, 3330). parameters were being saved to the drive There is a faulty connection between the terminal board and the control board HOA Keypad Display CPF20 or CPF21 Cause Hardware is damaged HOA Keypad Display CPF22 Cause Hybrid IC failure on the power board HOA Keypad Display CPF23 Cause Hardware is damaged HOA Keypad Display CPF24 Cause Hardware is damaged Fault Name Terminal Board Connection Error Possible Solution • Turn off the power and reconnect the terminal board. • If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. Fault Name Control Circuit Error Possible Solution • Cycle power to the drive. • If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. Fault Name Hybrid IC Failure Possible Solution • Cycle power to the drive. • If the problem continues, replace the power board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the power board. Fault Name Control Board Connection Error Connection error between the control board and the drive Possible Solution • Turn off the power and check the connection between the control board and the drive. • If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. Fault Name Drive Unit Signal Fault The drive capacity cannot be detected correctly (drive capacity is checked when the drive is powered up). Possible Solution If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 177 Troubleshooting HOA Keypad Display CPF07 or CPF08 Cause 5 5.2 Fault Detection HOA Keypad Display Fault Name CPF25 Terminal Board Not Connected Cause Possible Solution Terminal board is not connected correctly Reconnect the terminal board to the connector on the drive, then cycle the power to the drive. HOA Keypad Display CPF26 to CPF35 CPF40 to CPF43 Cause Hardware is damaged Fault Name Control Circuit Error CPU error Possible Solution If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. HOA Keypad Display E5 Fault Name SI-T3 Watchdog Timer Error The watchdog timed out. Cause Possible Solution Data has not been received from the PLC Execute DISCONNECT or ALM_CLR, then issue a CONNECT command or SYNC_SET command and proceed to phase 3. Refer to the SI-T3 Option Technical Manual for more details on troubleshooting. HOA Keypad Display EF0 Fault Name Option Card External Fault An external fault condition is present. Cause Possible Solution An external fault was received from the • Remove the cause of the external fault. PLC and F6-03 is set to a value other than • Remove the external fault input from the PLC. 3. Problem with the PLC program HOA Keypad Display EF1 EF2 EF3 EF4 EF5 EF6 EF7 EF8 Cause An external device tripped an alarm function Wiring is incorrect Multi-function contact input setting is incorrect 178 Check the PLC program and correct problems. Fault Name Pump Fault (input terminal S1) External fault at multi-function input terminal S1. Pump Fault (input terminal S2) External fault at multi-function input terminal S2. Pump Fault (input terminal S3) External fault at multi-function input terminal S3. Pump Fault (input terminal S4) External fault at multi-function input terminal S4. Pump Fault (input terminal S5) External fault at multi-function input terminal S5. Pump Fault (input terminal S6) External fault at multi-function input terminal S6. Pump Fault (input terminal S7) External fault at multi-function input terminal S7. Pump Fault (input terminal S8) External fault at multi-function input terminal S8. Possible Solution Remove the cause of the external fault and reset the fault. • Properly connect the signal lines to the terminals assigned for external fault detection (H1-oo = 20 to 2B). • Reconnect the signal line. • Check for unused terminals set for H1-oo = 20 to 2B (External Fault). • Change the terminal settings. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.2 Fault Detection HOA Keypad Display Err Fault Name EEPROM Write Error Data cannot be written to the EEPROM Cause Possible Solution • • Noise has corrupted data while writing to • the EEPROM • Press “ENTER” on the digital operator. Correct the parameter setting. Cycle power to the drive. If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. Hardware problem HOA Keypad Display FAn Cause Internal cooling fan has malfunctioned Fault Name Internal Fan Fault Fan or magnetic contactor failure Possible Solution • Cycle power to the drive. • Check for fan operation. • Verify the cumulative operation time of the fan with monitor U4-03, and verify the cumulative operation time of the fan maintenance timer with U4-04. • If the cooling fan has exceeded its expected performance life or is damaged in any other way, follow the replacement instructions in the Peripheral Devices & Options chapter. • Cycle power to the drive. Fault detected in the internal cooling fan or • If the fault continues to occur, replace the power board/gate drive board or the entire drive. magnetic contactor to the power supply. • Contact Yaskawa or a Yaskawa representative for instructions on replacing the power board/gate drive board. HOA Keypad Display FDBKL Wire Break Cause The analog input programmed for PID feedback loss has risen above 21 mA or fallen below 3 mA. This is effective only when b5-12 Feedback Loss 4 to 20 mA Detection Selection is set to 2 (fault). Fault Name PID Feedback Loss The analog input programmed for PID feedback has risen above 21 mA or fallen below 3 mA. Possible Solution • Confirm that the PID feedback source is installed and working properly. • Drive response to this condition is controlled by b5-12, Feedback Loss 4 to 20 mA Detection Selection and b5-13, Feedback Loss Go To Frequency. • Auto-restart of this fault is controlled by L5-42, Feedback Loss Fault Retry Selection. Fault Name Ground Fault GF • A current short to ground exceeded 50% of rated current on the output side of the drive. • Setting L8-09 to 1 enables ground fault detection. Cause Possible Solution • Check the insulation resistance of the motor. Motor insulation is damaged • Replace the motor. • Check the motor cable. A damaged motor cable is creating a short • Remove the short circuit and reapply power to the drive circuit • Check the resistance between the cable and the ground terminal . • Replace the cable. • Reduce the carrier frequency. Excessive leakage current at the drive output • Reduce the amount of stray capacitance. • Set b3-01 to 1 to enable Speed Search at Start. The drive started to run during a current offset fault or while coasting to a stop • Perform Speed Search 1 or 2 (H1-oo = 61 or 62) via one of the external terminals. If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa Hardware problem representative for instructions on replacing the control board. HOA Keypad Display HFB Troubleshooting HOA Keypad Display 5 Fault Name High Feedback The feedback signal is too high. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 179 5.2 Fault Detection Cause The feedback signal has risen above the level set in P1-11, High Feedback Level, for the time set in P1-12, High Feedback Level Fault Delay Time. This is effective only when P1-13, High Feedback Selection, is set to 0 (Fault and digital outt). HOA Keypad Display HIFLO High Flow Possible Solution • Set the High Feedback fault characteristics in P1-11 and P1-12. • Drive response to this condition is controlled by P1-13, High Feedback Selection. Auto-restart of this fault is controlled by L5-41, High Feedback Fault Retry Selection. Fault Name High Flow The meter has detected a high flow condition. Possible Solution Reduce the flow Cause The flow is too high The measured water flow has risen above • Set the High Flow fault characteristics in P6-17 and P6-18. the P6-17 level for the time set in P6-18. • Drive response to this condition is controlled by P1-19, High Flow Select. This is only effective when P1-19, High • Auto-restart of this fault is controlled by P1-19, High Flow Select. Flow Select is set to 2 (fault). HOA Keypad Display HISUC High Suction Cause Fault Name High Section Pressure The suction pressure has fallen below the • level set in Q5-12 for longer than the time • set in Q5-13. This is only effective when • Q5-14, High Suction Pressure Behavior • Select is set to 2 (fault). Possible Solution Reduce the system pressure. Set the High Suction Pressure fault characteristics in Q5-12, Q5-13, and Q5-18. Drive response to this condition is controlled by Q5-14, High Suction Pressure Behavior Select. Auto-restart of this fault is controlled by Q5-14, High Suction Pressure Behavior Select and Q5-15, Suction Pressure Auto-restart Time. HOA Keypad Display HWL Fault Name High Water Level The “High Water Level” digital input is active (H1-0o = 90). Possible Solution Cause The Low Water Level switch is activated or Lower the water level and/or adjust the High Water Level switch. P1-31, High Water Digital Input Configuration, is programmed incorrectly. HOA Keypad Display LF Cause The output cable is disconnected The motor winding is damaged The output terminal is loose Fault Name Output Phase Loss • Phase loss on the output side of the drive. • Setting L8-07 to 1 or 2 enables Phase Loss Detection. Possible Solution • Check for wiring errors and properly connect the output cable. • Correct the wiring. • Check the resistance between motor lines. • Replace the motor if the winding is damaged. • Apply the tightening torque specified in this manual to fasten the terminals. Refer to Wire Gauges and Tightening Torque on page 87 for details. The rated current of the motor being used Check the drive and motor capacities. is less than 5% of the drive rated current If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa An output transistor is damaged representative for instructions on replacing the control board. A single-phase motor is being used The drive cannot operate a single phase motor. HOA Keypad Display LFB Cause 180 Fault Name Low Feedback The feedback signal is too low. Possible Solution YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.2 Fault Detection The feedback signal has dropped below the level set in P1-08, Low Feedback Level, for the time set in P1-09, Low Feedback Level • Set the Low Feedback fault characteristics in P1-08 and P1-09. • Drive response to this condition is controlled by P1-10, Low Feedback Selection. Fault Delay Time. This is effective only when P1-10, Low • Auto-restart of this fault is controlled by L5-40, Low Feedback Fault Retry Selection. Feedback Selection, is set to 0 (Fault and digital out). HOA Keypad Display Cause The pump load, measured based on the P1-18 setting (output current, kilowatts, or power), has dropped below the level set in P1-19, Prime Loss Level, for the time set in P1-20, Loss of Prime Time, and the output frequency has risen above P1-21, Prime Loss Frequency. This is effective only when P1-22 Loss of Prime Selection is set to 0 (fault). HOA Keypad Display LOSUC Low Suction Cause The suction pressure has fallen below the level set in Q5-09 for longer than the time set in Q5-10. This is only effective when Q5-11, Low Suction Pressure Behavior Select is set to 2 (fault). HOA Keypad Display LOWFL Low Flow Cause Insufficient flow After waiting the P6-08 delay time at start, the measured water flow has fallen below the P6-06 level for the time set in P6-07. This is only effective when P1-09, Low Flow Select is set to 2 (fault). HOA Keypad Display LOWWL Low Water Level Cause Possible Solution • Check for a dry well, air in the system, or no water in the system. Restart the pump using the preferred priming method suggested by the pump manufacturer. • Set the Loss of Prime fault characteristics in P1-18, P1-19, P1-20, and P1-21. • Drive response to this condition is controlled by P1-21, Loss of Prime Selection. • Auto-restart of this fault is controlled by L5-51, Loss of Prime Fault Retry Selection and P1-23, Loss of Prime Maximum Restart Time after Fault Fault Name Low Section Pressure Possible Solution • • • • Increase the system pressure. Set the Low Suction fault characteristics in Q5-09, Q5-10, and Q5-18. Drive response to this condition is controlled by Q5-11, Low Suction Pressure Behavior Select. Auto-restart of this fault is controlled by Q5-11, Low Suction Pressure Behavior Select and Q5-15, Suction Pressure Auto-restart Time. Fault Name Low Flow Possible Solution Increase flow • Set the Low Flow fault characteristics in P6-06, P6-07, and P6-08. • Drive response to this condition is controlled by P6-09, Low Flow Select. • Auto-restart of this fault is controlled by P6-09, Low Flow Select and P6-10, Low Flow Auto-restart Time. Fault Name Low Water Level The water level has fallen below the level • set in Q4-09 for the longer than the time set • in Q4-10. This is only effective when • Q4-11, Low Level Behavior is set to 2 • (fault). Possible Solution Raise the water level. Set the Low Water Level fault characteristics in Q4-09 and Q4-10. Drive response to this condition is controlled by Q4-11, Low Level Behavior. Auto-restart of this fault is controlled by Q4-11, Low Level Behavior and Q4-12 Water Level Control Auto-restart Time. HOA Keypad Display LWL 5 Fault Name Low Water Level The “Low Water Level” digital input is active (H1-0o = 8F). Possible Solution Cause The Low Water Level switch is activated, defective, or P1-30, Low Water Digital Raise the water level and/or adjust the Low Water Level switch. Input Configuration, is programmed incorrectly. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Troubleshooting LOP Fault Name Loss of Prime The pump has lost its prime. 181 5.2 Fault Detection HOA Keypad Display MSL Net Master Lost Fault Name Net Master Lost The MEMOBUS master has been lost Cause Possible Solution Network Recovery is set to Fault MSL • Increase the P9-26 setting to account for network latency. P9-27 = 3) and no message has been received from the master within the time set • Verify that there is a drive on the network with parameter P1-01 set to 3 and P9-27 to 0. • Check network connections and verify H5-01 and P9-25 settings for all drives on the network. in P9-26. HOA Keypad Display Fault Name Not Maintaining Setpoint NMS The setpoint cannot be maintained and P1-17 is set to 0. Cause Possible Solution • Check for a blocked impeller, over cycling, or broken pipe. When the feedback deviates from the setpoint at a level greater than P1-15, for a • Set the Not Maintaining Setpoint fault characteristics in P1-16 and P1-17. time set in P1-16. This is effective only • Drive response to this condition is controlled by P1-17, Not Maintaining Setpoint Selection. when P1-17 is set to 0 (fault). • Auto-restart of this fault is controlled by L5-50, Setpoint Not Met Retry. HOA Keypad Display nSE Fault Name Node Setup Error A terminal assigned to the node setup function closed during run. Possible Solution Cause The node setup terminal closed during run. A Run command was issued while the node Stop the drive when using the node setup function. setup function was active. HOA Keypad Display oC Cause The motor has been damaged due to overheating or the motor insulation is damaged Fault Name Overcurrent Drive sensors detected an output current greater than the specified overcurrent level. Possible Solution • Check the insulation resistance. • Replace the motor. • Check the motor cables. One of the motor cables has shorted out or • Remove the short circuit and reapply power to the drive. there is a grounding problem • Check the resistance between the motor cables and the ground terminal • Replace damaged cables. . • Measure the current flowing into the motor. • Replace the drive with a larger capacity drive if the current value exceeds the rated current. The load is too heavy • Determine if there is sudden fluctuation in the current level. • Reduce the load to avoid sudden changes in the current level or switch to a larger drive. Calculate the torque needed during acceleration relative to the load inertia and the specified acceleration time. If it is not possible to set the proper amount of torque, make the following changes: The acceleration or deceleration times are • Increase the acceleration time (C1-01, C1-03). too short • Increase the S-curve characteristics (C2-01 through C2-04). • Increase the capacity of the drive. • Check the motor capacity. The drive is attempting to operate a specialized motor or a motor larger than the • Ensure that the rated capacity of the drive is greater than or equal to the capacity rating found on the motor maximum size allowed nameplate. Magnetic contactor (MC) on the output side Set up the operation sequence so the MC does not trip while the drive is outputting current. of the drive has turned on or off • Check the ratios between the voltage and frequency. V/f setting is not operating as expected • Set parameters E1-04 through E1-10 appropriately. • Lower the voltage if it is too high relative to the frequency. • Check the amount of torque compensation. Excessive torque compensation • Reduce the torque compensation gain (C4-01) until there is no speed loss and less current. 182 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.2 Fault Detection • Review the possible solutions provided for handling noise interference. Drive fails to operate properly due to noise • Review the section on handling noise interference and check the control circuit lines, main circuit lines, interference and ground wiring. • Check if the fault occurs simultaneously with overexcitation function operation. Overexcitation gain is set too high • Consider motor flux saturation and reduce the value of n3-13 (Overexcitation Deceleration Gain). • Set b3-01 to 1 to enable Speed Search at Start. Run command was applied while motor • Program the Speed Search command input through one of the multi-function contact input terminals was coasting (H1-oo = 61 or 62). The rated output current of the drive is too Use a larger drive. small HOA Keypad Display oFA00 Fault Name Option Card Connection Error at Option Port CN5-A Option compatibility error Possible Solution Cause The option card installed into port CN5-A Check if the drive supports the option card to be installed. Contact Yaskawa for assistance. is incompatible with the drive HOA Keypad Display oFA01 Fault Name Option Card Fault at Option Port CN5-A Option not properly connected Cause Possible Solution • Turn off the power and reconnect the option card. The option card connection to port CN5-A • Check if the option card is properly plugged into the option port. Make sure the card is fixed properly. • If the option is not a communication option card, try to use the card in a different option port. If the option is faulty card works properly in a different option port, CN5-A is damaged, and the drive requires replacement. If the error persists (oFb01 or oFC01 occur), replace the option card. Option card or hardware is damaged Fault Name Option Card Error Occurred at Option Port CN5-A Option Card Connection Error (CN5-A) Communication Option Card Connection Error (CN5-A) Possible Solution • Cycle power to the drive. • If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. HOA Keypad Display oFb00 Fault Name Option Card Fault at Option Port CN5-B Option compatibility error Cause Possible Solution The option card installed into port CN5-B Make sure the drive supports the option card to be installed. Contact Yaskawa for assistance. is incompatible with the drive A communication option card has been Communication option cards are only supported by option port CN5-A. It is not possible to install more than installed in option port CN5-B one communication option. HOA Keypad Display oFb01 Fault Name 5 Option Card Fault at Option Port CN5-B Option not properly connected Cause Possible Solution • Turn off the power and reconnect the option card. The option card connection to port CN5-B • Check if the option card is properly plugged into the option port. Make sure the card is fixed properly. • Try to use the card in a different option port. If the option card works properly in a different option port, is faulty CN5-B is damaged, and the drive requires replacement. If the error persists (oFA01 or oFC01 occur), replace the option card. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Troubleshooting HOA Keypad Display oFA03 to oFA06 oFA10, oFA11 oFA12 to oFA17 oFA30 to oFA43 Cause 183 5.2 Fault Detection HOA Keypad Display Fault Name Option Card Fault at Option Port CN5-B oFb02 Same type of option card is currently connected Cause Possible Solution An option card of the same type is already Only one of each option card type can only be installed simultaneously. Make sure only one type of option installed in option port CN5-A card is connected. An input option card is already installed in Install a communication option. More than one of the same type of card cannot be installed simultaneously. option port CN5-A HOA Keypad Display oFb03 to oFb11 oFb12 to oFb17 Cause Option card or hardware is damaged HOA Keypad Display oFC00 Fault Name Option card error occurred at Option Port CN5-B Possible Solution • Cycle power to the drive. • If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. Fault Name Option Card Connection Error at Option Port CN5-C Option compatibility error Possible Solution Cause The option card installed into port CN5-C Confirm that the drive supports the option card to be installed. Contact Yaskawa for assistance. is incompatible with the drive A communication option card has been installed in option port CN5-C Communication option cards are only supported by option port CN5-A. It is not possible to install more than one communication option. HOA Keypad Display oFC01 Fault Name Option Card Fault at Option Port CN5-C Option not properly connected Cause Possible Solution • Turn the power off and reconnect the option card. The option card connection to port CN5-C • Check if the option card is properly plugged into the option port. Make sure the card is fixed properly. • Try to use the card in a different option port. If the option card works properly in a different option port, is faulty. CN5-C is damaged, and the drive requires replacement. If the error persists (oFA01 or oFb01 occur), replace the option card. HOA Keypad Display Fault Name Option Card Fault at Option Port CN5-C oFC02 Same type of option card is currently connected Cause Possible Solution An option card of the same type is already Only one of each option card type can only be installed simultaneously. Make sure only one type of option installed in option port CN5-A or CN5-B. card is connected. An input option card is already installed in Install a communication option, a digital input option, or an analog input option. More than one of the same option port CN5-A or CN5-B. type of card cannot be installed simultaneously. HOA Keypad Display oFC03 to oFC11 oFC12 to oFC17 Cause Option card or hardware is damaged HOA Keypad Display oFC50 to oFC55 Cause Option card or hardware is damaged 184 Fault Name Option Card Error Occurred at Option Port CN5-C Possible Solution • Cycle power to the drive. • If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa representative for instructions on replacing the control board. Fault Name Option Card Error Occurred at Option Port CN5-C Possible Solution Refer to the option manual for details. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.2 Fault Detection HOA Keypad Display oH Cause Surrounding temperature is too high Load is too heavy Internal cooling fan is stopped HOA Keypad Display oH1 Fault Name Heatsink Overheat The heatsink temperature exceeded the overheat pre-alarm level set to L8-02. Possible Solution • Check the temperature surrounding the drive. Verify temperature is within drive specifications. • Improve the air circulation within the enclosure panel. • Install a fan or air conditioner to cool the surrounding area. • Remove anything near the drive that might be producing excessive heat. • Measure the output current. • Decrease the load. • Lower the carrier frequency (C6-02). • Replace the cooling fan. . • After replacing the cooling fan, set parameter o4-03 to 0 to reset the cooling fan maintenance. Fault Name Overheat 1 (Heatsink Overheat) The heatsink temperature exceeded the drive overheat level. Cause Possible Solution Check the temperature surrounding the drive. Improve the air circulation within the enclosure panel. Install a fan or air conditioner to cool the surrounding area. Remove anything near the drive that might be producing excessive heat. Surrounding temperature is too high • • • • Load is too heavy • Measure the output current. • Lower the carrier frequency (C6-02). • Reduce the load. HOA Keypad Display oL1 Cause Load is too heavy Cycle times are too short during acceleration and deceleration Fault Name Motor Overload The electronic motor overload protection tripped Possible Solution Reduce the load. Increase the acceleration and deceleration times (C1-01 through C1-04). • Reduce the load. • Increase the speed. • If the motor is supposed to operate at low speeds, either increase the motor capacity or use a motor specifically designed to operate in the desired speed range. • Adjust the user-set V/f pattern (E1-04 through E1-10) by reducing E1-08 and E1-10. The output voltage is too high • Do not set E1-08 and E1-10 too low. This reduces load tolerance at low speeds. • Check the motor-rated current. The wrong motor rated current is set to E2-01 • Enter the motor rated current to parameter E2-01 as indicated on the motor nameplate. • Check the rated frequency indicated on the motor nameplate. The base frequency is set incorrectly • Enter the rated frequency to E1-06 (Base Frequency). • Check the motor characteristics. The electrical thermal protection characteristics and motor overload • Correct the type of motor protection that has been selected (L1-01). characteristics do not match • Install an external thermal relay. The electrical thermal relay is operating at • Check the current rating listed on the motor nameplate. the wrong level • Check the value set for the motor rated current (E2-01). • Overexcitation increases the motor loss and the motor temperature. Excessive duration of overexcitation may cause motor damage. Prevent excessive overexcitation operation or apply proper cooling to the motor. Motor overheated by overexcitation operation • Reduce the excitation deceleration gain (n3-13). • Set L3-04 (Stall Prevention during Deceleration) to a value other than 4. • Check values set to Speed Search related parameters. Parameters related to Speed Search are set • Adjust the Speed Search current and Speed Search deceleration times (b3-02 and b3-03 respectively). incorrectly • After Auto-Tuning, set b3-24 to 1 to enable Speed Estimation Speed Search. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 185 Troubleshooting A general-purpose motor is driven below the rated speed with a high load 5 5.2 Fault Detection Output current fluctuation due to power supply loss HOA Keypad Display oL2 Cause Load is too heavy Acceleration or deceleration time is too short Check the power supply for phase loss. Fault Name Drive Overload The thermal sensor of the drive triggered overload protection. Possible Solution Reduce the load. Increase the settings for the acceleration and deceleration times (C1-01 through C1-04). • Adjust the preset V/f pattern (E1-04 through E1-10) by reducing E1-08 and E1-10. • Do not lower E1-08 and E1-10 excessively. This reduces load tolerance at low speeds. Drive capacity is too small Replace the drive with a larger model. • Reduce the load when operating at low speeds. Overload occurred when operating at low • Replace the drive with a model that is one frame size larger. speeds • Lower the carrier frequency (C6-02). Excessive torque compensation Reduce the torque compensation gain in parameter C4-01 until there is less current but no speed loss. • Check the settings for all Speed Search related parameters. Parameters related to Speed Search are set • Adjust the current used during Speed Search (b3-03) and the Speed Search deceleration time (b3-02). incorrectly • After Auto-Tuning, set b3-24 to 1 to enable Speed Estimation Speed Search. Output current fluctuation due to input Check the power supply for phase loss. phase loss The output voltage is too high HOA Keypad Display oL3 Fault Name Overtorque Detection 1 The current has exceeded the value set for torque detection (L6-02) for longer than the allowable time (L6-03). Possible Solution Cause Parameter settings are not appropriate for Check L6-02 and L6-03 settings. the load Fault on the machine side (e.g., machine is Check the status of the load. Remove the cause of the fault. locked up) HOA Keypad Display oL4 Fault Name Overtorque Detection 2 The current has exceeded the value set for Overtorque Detection 2 (L6-05) for longer than the allowable time (L6-06). Possible Solution Cause Parameter settings are not appropriate for Check the settings of parameters L6-05 and L6-06. the load HOA Keypad Display oL7 Cause Excessive load inertia Motor is driven by the load Something on the load side is restricting deceleration The overload time during High Slip Braking is too short HOA Keypad Display oPr 186 Fault Name High Slip Braking oL The output frequency stayed constant for longer than the time set to n3-04 during High Slip Braking. Possible Solution • Reduce deceleration times in parameters C1-02 and C1-04 for applications that do not use High Slip Braking. • Use a braking resistor to shorten deceleration time. • Increase parameter n3-04 (High-slip Braking Overload Time). • Install a thermal relay and increase the setting of n3-04 to maximum value. Fault Name External HOA Keypad Connection Fault The HOA keypad has been disconnected from the drive. Note: An oPr fault will occur when all of the following conditions are true: • Output is interrupted when the keypad is disconnected (o2-06 = 1). • The Run command is assigned to the operator (b1-02 = 0 and LOCAL has been selected). YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.2 Fault Detection Cause Possible Solution • Check the connection between the keypad and the drive. HOA keypad is not properly connected to • Replace the cable if damaged. the drive • Turn off the drive input power and disconnect the keypad. Reconnect the keypad and reapply drive input power. Fault Name Overvoltage Voltage in the DC bus has exceeded the overvoltage detection level. ov • For 200 V class drives: approximately 410 V • For 400 V class drives: approximately 820 V (740 V when E1-01 is less than 400) • For 600 V class drives: approximately 1040 V Cause Possible Solution • Increase the deceleration time (C1-02 and C1-04). Deceleration time is too short and • Install a dynamic braking resistor or a dynamic braking resistor unit. regenerative energy is flowing from the • Set L3-04 to 1 to enable stall prevention during deceleration. Stall Prevention is enabled as the default motor into the drive setting. • Check if sudden drive acceleration triggers an overvoltage alarm. • Increase the acceleration time. Fast acceleration time causes the motor to • Use longer S-curve acceleration and deceleration times. overshoot the speed reference • Enable the Overvoltage Suppression function (L3-11 = 1). • Lengthen the S-curve at acceleration end. The braking torque was too high, causing regenerative energy to charge the DC bus. Reduce the braking Excessive braking load torque, use a dynamic braking option, or lengthen decel time. Install a DC link choke. Surge voltage entering from the drive input Note: Voltage surge can result from a thyristor convertor and phase advancing capacitor using the power same input power supply. Ground fault in the output circuit causes the • Check the motor wiring for ground faults. DC bus capacitor to overcharge • Correct grounding shorts and reapply power. • Check the settings for Speed Search-related parameters. Improper parameters related to Speed • Enable Speed Search restart function (b3-19 greater than or equal to 1 to 10). Search (including Speed Search after a • Adjust the current level during Speed Search and the deceleration time (b3-02 and b3-03 respectively). momentary power loss and after a fault restart) • Perform Stationary Auto-Tuning for line-to-line resistance and then set b3-14 to 1 to enable Speed Estimation Speed Search. • Check the voltage. Drive input power voltage is too high • Lower drive input power voltage within the limits listed in the specifications. The braking transistor or braking resistor • Check braking transistor and braking resistor wiring for errors. are wired incorrectly • Properly rewire the braking resistor device. • Review the list of possible solutions provided for controlling noise. Drive fails to operate properly due to noise • Review the section on handling noise interference and check the control circuit lines, main circuit lines, interference and ground wiring. • Check the load inertia settings when using KEB, overvoltage suppression, or Stall Prevention during deceleration. Load inertia is set incorrectly • Adjust the load inertia ratio in L3-25 to better match the load. • Adjust the parameters that control hunting. Motor hunting occurs • Set the gain for Hunting Prevention (n1-02). • Adjust the AFR time constant (n2-02 and n2-03). HOA Keypad Display 5 Fault Name Input Phase Loss Drive input power has an open phase or has a large imbalance of voltage between phases. Detected when L8-05 is set 1 (enabled). Cause Possible Solution • Check for wiring errors in the main circuit drive input power. There is phase loss in the drive input power • Correct the wiring. PF YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Troubleshooting HOA Keypad Display 187 5.2 Fault Detection • Ensure the terminals are tightened properly. • Apply the tightening torque as specified in this manual. Refer to Wire Gauges and Tightening Torque on page 87 for details. There is excessive fluctuation in the drive • Check the voltage from the drive input power. input power voltage • Review the possible solutions for stabilizing the drive input power. There is poor balance between voltage Stabilize drive input power or disable phase loss detection. phases • Check the maintenance time for the capacitors (U4-05). • Replace the capacitor if U4-05 is greater than 90%. For instructions on replacing the capacitor, contact Yaskawa or a Yaskawa representative. The main circuit capacitors are worn out Check for problems with the drive input power. If drive input power appears normal but the alarm continues to occur, replace either the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or a Yaskawa representative. There is loose wiring in the drive input power terminals HOA Keypad Display PoC Cause Fault Name Pump Over Cycle • • The pump has exceeded the number of cycles set in P2-10 in the time set in P2-11 • and P2-12 is set to 2 (fault). • HOA Keypad Display rF Possible Solution Set the Pump Over Cycle fault characteristics in P2-10 and P2-11. Drive response to this condition is controlled by P2-12, Over Cycling Mode. Auto-restart of this fault is controlled by L5-52, Pump Over Cycle Fault Retry Selection. Set the Pump Over Cycle automatic setpoint compensation in P2-12, Over Cycling Mode, P2-13, Setpoint Compensation, and P2-14, Maximum Setpoint Compensation. Fault Name Braking Resistor Fault The resistance of the braking resistor is too low. Possible Solution Cause The proper braking resistor option has not Select a braking resistor option that it fits the drive braking transistor specification. been installed A regenerative converter, regenerative unit, Set L8-55 to 0 to disable the braking transistor protection selection. or braking unit is being used HOA Keypad Display Fault Name Braking Resistor Overheat rH Braking resistor protection was triggered. Fault detection is enabled when L8-01 = 1 (disabled as a default). Cause Possible Solution • Check the load, deceleration time, and speed. Deceleration time is too short and excessive • Reduce the load inertia. regenerative energy is flowing back into the • Increase the deceleration times (C1-01 to C1-04). drive • Replace the dynamic braking option with a larger device that can handle the power that is discharged. The duty cycle is too high Check the duty cycle. Maximum of 3% duty cycle is available when L8-01 = 1. Excessive braking inertia Recalculate braking load and braking power. Reduce the braking load by adjusting braking resistor settings. The braking operation duty cycle is too Check the braking operation duty cycle. Braking resistor protection for ERF-type braking resistors high (L8-01 = 1) allows a braking duty cycle of maximum 3%. The proper braking resistor has not been • Check the specifications and conditions for the braking resistor device. installed • Select the optimal braking resistor. Note: The magnitude of the braking load trips the braking resistor overheat alarm, NOT the surface temperature. Using the braking resistor more frequently than its rating permits will trip the alarm even when the braking resistor surface is not very hot. HOA Keypad Display rr Cause The braking transistor is damaged The control circuit is damaged 188 Fault Name Dynamic Braking Transistor The built-in dynamic braking transistor failed. Possible Solution • Cycle power to the drive and check for reoccurrence of the fault. • Replace either the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or a Yaskawa representative. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.2 Fault Detection HOA Keypad Display SC Cause IGBT fault IGBT short circuit detection circuit fault The drive is damaged Fault Name IGBT Short Circuit or Ground Fault Possible Solution • Check motor wiring. • Turn off the power supply, then turn it on. If the problem continues, contact your Yaskawa representative or the nearest Yaskawa sales office. • Check the drive output side short circuit for a broken output transistor B1 and U/T1, V/T2, W/T3 – and U/T1, V/T2, W/T3 • Contact your Yaskawa representative or nearest Yaskawa sales office. HOA Keypad Display Fault Name Too Many Speed Search Restarts SEr The number of Speed Search restarts exceeded the value set to b3-19. Cause Possible Solution • Reduce the detection compensation gain during Speed Search (b3-10). Parameters related to Speed Search are set • Increase the current level when attempting Speed Search (b3-17). to the wrong values • Increase the detection time during Speed Search (b3-18). • Repeat Auto-Tuning. The motor is coasting in the opposite direction of the Run command Set b3-14 to 1 to enable Bi-Directional Speed Search. HOA Keypad Display Single Phase Foldback Fault Name Single Phase Foldback Output speed is being limited due to excessive DC Bus voltage ripple. Possible Solution Cause An input phase has been lost. In single phase applications, excess load is Reduce the output load. being drawn by the motor. HOA Keypad Display Suction Pressure Loss Wire-break detection for suction pressure. Cause An analog input programmed for setting 23 “WaterLvl/Suction” has dropped below 3 Repair pressure sensor or wiring. mA or risen above 21 mA for longer than 1 second. HOA Keypad Display TdE Cause An error has occurred in the Real-Clock Time function of the HOA keypad. HOA Keypad Display TIE Cause An error has occurred in the Real-Clock Time function of the HOA keypad. HOA Keypad Display TIM Cause Possible Solution Fault Name Time Data Error Possible Solution Replace the HOA keypad. For instructions on replacing the HOA keypad, contact Yaskawa or your nearest sales representative. Fault Name Time Interval Error Possible Solution Replace the HOA keypad. For instructions on replacing the HOA keypad, contact Yaskawa or your nearest sales representative. Fault Name Time Not Set Possible Solution YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 189 Troubleshooting SPL Suction Pressure Loss Fault Name 5 5.2 Fault Detection The Real-Time Clock for the HOA keypad is not set in parameter o4-17 and a feature that requires RTC information is enabled. • The drive is a new drive, first power-up condition • o4-17 was set to 2, Reset, by the user, manually clearing the Real-Time Clock data. The user did not set the Real Time Clock when prompted following power-up. The HOA keypad battery is low or the battery has been replaced. An error has occurred in the Real-Time Clock function of the HOA keypad. Set o4-17 to 1 to set the time for the HOA keypad. The drive will display the "Clock Not Set" alarm when the Real time Clock is not set. Additionally, at power up, if the "TIM" condition is present, the drive will automatically switch to the time setting screen (o4-17 = 1) for 30 seconds to prompt the user to set the Real-Time Clock. Cycle power to the drive and set the Real Time Clock within 30 seconds of power-up, or set the clock manually via parameter o4-17. Replace the HOA keypad battery and set the Real-Time Clock. Replace the digital operator. For instructions on replacing the HOA keypad, contact Yaskawa or your nearest sales representative. HOA Keypad Display TLGI Geothermal Input Fault Name Temperature Lost Geothermal Input The geothermal input is not present. Cause Possible Solution The input signal level has dropped below 3 mA or risen above 21 mA when the drive was running and b1-01 = 5, H3-0o = 21 Confirm that the device connected to the analog input terminal is installed and working properly. (Geothermal Input), H3-0o = 2 (4 to 20 mA), and Q2-09 = 2 (Fault). The drive was running while b1-01 = 5, H3-0o≠ 21 (Geothermal Temp), and Q2-09 = 2 (Fault). HOA Keypad Display UL3 Assign one of the analog inputs to “Geothermal Temperature”, H3-0o = 21. Fault Name Undertorque Detection 1 The current has fallen below the minimum value set for torque detection (L6-02) for longer than the allowable time (L6-03). Possible Solution Cause Parameter settings are not appropriate for Check the settings of parameters L6-02 and L6-03. the load There is a fault on the machine side Check the load for any problems. HOA Keypad Display UL4 Fault Name Undertorque Detection 2 The current has fallen below the minimum value set for torque detection (L6-05) for longer than the allowable time (L6-06). Possible Solution Cause Parameter settings are not appropriate for Check L6-05 and L6-06 settings the load There is a fault on the machine side Check the load for any problems. HOA Keypad Display UL6 Fault Name Motor Underload The load has fallen below the underload curve defined in L6-14. Possible Solution Cause The output current has fallen below the Adjust the value set to L6-14 so that output current remains above the motor underload curve during normal motor underload curve defined in L6-14 for operation. longer than the time set to L6-03 190 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.2 Fault Detection HOA Keypad Display Uv1 Cause Input power phase loss One of the drive input power wiring terminals is loose There is a problem with the voltage from the drive input power The power has been interrupted The main circuit capacitors are worn The relay or contactor on the soft-charge bypass circuit is damaged HOA Keypad Display Uv2 Fault Name DC Bus Undervoltage One of the following conditions occurred while the drive was running: • Voltage in the DC bus fell below the undervoltage detection level (L2-05). • For 200 V class drives: approximately 190 V • For 400 V class drives: approximately 380 V (350 V when E1-01 is less than 400) • For 600 V class drives: approximately 475 V The fault is output only if L2-01 is set to 0 or 1 and the DC bus voltage has fallen below the level set to L2-05 for longer than the time set to L2-02. Possible Solution • The main circuit drive input power is wired incorrectly. • Correct the wiring. • Ensure there are no loose terminals. • Apply the tightening torque specified in this manual to fasten the terminals. Refer to Wire Gauges and Tightening Torque on page 87 for details. • Check the voltage. • Correct the voltage to be within the range listed in drive input power specifications. • If there is no problem with the power supply to the main circuit, check for problems with the main circuit magnetic contactor. Correct the drive input power. • Check the maintenance time for the capacitors (U4-05). • Replace either the control board or the entire drive if U4-05 exceeds 90%. For instructions on replacing the control board, contact Yaskawa or a Yaskawa representative. • Cycle power to the drive and see if the fault reoccurs. • If the problem continues, replace either the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or a Yaskawa representative. • Check monitor U4-06 for the performance life of the soft-charge bypass. • Replace either the control board or the entire drive if U4-06 exceeds 90%. For instructions on replacing the control board, contact Yaskawa or a Yaskawa representative. Fault Name Control Power Supply Voltage Fault Voltage is too low for the control drive input power. Possible Solution Control power supply wiring is damaged Internal circuitry is damaged HOA Keypad Display Uv3 Cause The relay or contactor on the soft-charge bypass circuit is damaged HOA Keypad Display VLTS Cause • Cycle power to the drive. Check if the fault reoccurs. • If the problem continues, replace the control board, the entire drive, or the control power supply. For instructions on replacing the control board, contact Yaskawa or a Yaskawa representative. • Cycle power to the drive. Check if the fault reoccurs. • If the problem continues, replace either the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or a Yaskawa representative. Fault Name Undervoltage 3 (Soft-Charge Bypass Circuit Fault) The soft-charge bypass circuit failed. Possible Solution • Cycle power to the drive and see if the fault reoccurs. • If the problem continues, replace either the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or a Yaskawa representative. • Check monitor U4-06 for the performance life of the soft-charge bypass. • Replace either the control board or the entire drive if U4-06 exceeds 90%. For instructions on replacing the control board, contact Yaskawa or a Yaskawa representative. Fault Name Volute-Thermostat Fault YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Possible Solution 191 Troubleshooting Cause In drive models 2A0004 to 2A0056 or 4A0002 to 4A0031, L2-02 was changed Correct the setting to L2-02 or install an optional Momentary Power Loss Ride-Thru unit. from its default value without installing a Momentary Power Loss Ride-Thru unit 5 5.2 Fault Detection The digital input assigned to the volute/ Check the wiring or wait for the volute or motor to cool. thermostat input (H1-0o = 88 or 89) is active. Both volute/thermostat inputs are • Program only one digital input to either H1-0o = 88 or H1-0o = 89. programmed simultaneously (H1-0o = 88 • Auto-restart of this fault is controlled by parameter L5-53, Volute-TStat Retry Selection. and 89). HOA Keypad Display voF Cause Hardware is damaged. Internal drive module MC / FAN overheat protection circuit board is due to abnormal ambient operating power. HOA Keypad Display vToL Cause The output current of the drive has been elevated for a set length of time. Fault Name Output Voltage Detection Fault Problem detected with the voltage on the output side of the drive. Possible Solution • Lower ambient temperature. • Replace the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or a Yaskawa representative. Fault Name VT Overload Possible Solution The application may not be suited for the drive • The application may not be suited for the drive • The drive is undersized for the load HOA Keypad Display WLL Water Level Loss Water Level Loss Cause An analog input programmed for setting 23 “WaterLvl/Suction” has dropped below 3 Repair level sensor or wiring. mA or risen above 21 mA for longer than 1 second. 192 Fault Name Possible Solution YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.3 Alarm Detection 5.3 Alarm Detection u Alarm Codes, Causes, and Possible Solutions Alarms are drive protection functions that do not necessarily cause the drive to stop. After removing the cause of an alarm, the drive will return to the same status is was before the alarm occurred. When an alarm has been triggered, the ALM light on the HOA keypad display blinks and the alarm code display flashes. If a multi-function output is set for an alarm (H2-oo = 10), that output terminal will be triggered. Note: If a multi-function output is set to close when an alarm occurs (H2-oo = 10), it will also close when maintenance periods are reached, triggering alarms LT-1 through LT-4 (triggered only if H2-oo = 2F). Table 5.3 Alarm Codes, Causes, and Possible Solutions HOA Keypad Display AnalogFB Lost Switched to Net Cause Defective or broken analog input source. H3-0o is not set to B (PI Feedback) HOA Keypad Display AnalogWL/SP Lost Switched to Net Minor Fault Name Analog Feedback Lost Analog feedback has not been detected and the network PI feedback signal is now used. Possible Solution Confirm that the PI feedback source is installed and working properly. If there is no feedback source, set P9-02 to 3 so the drive will read the network PI feedback from another drive. Set H3-0o to B if the analog input source is to be used for PI feedback. Set P9-02 to 3 if the drive does not have an analog PI feedback source. Minor Fault Name Analog Water Level / Suction Pressure Lost Network Water Level / Suction Pressure is now being used because a wire-break was detected with the analog signal. Water Level Analog Input Wire Break (WL Wire Break) is effective when Q4-16 is set to 1 (Alarm). Suction Pressure Analog Input Wire Break (SP Wire Break) is effective when Q5-19 is set to 1 (Alarm). Possible Solution Cause • Defective or broken analog input source. • Confirm that the Water Level or Suction Pressure source is installed and working properly. • Wire-break detected with the Water • Confirm that the Q4-16 and Q5-19 settings are correct. Level / Suction Pressure analog signal • Set P9-50 to 3 if the drive does not have an analog input source. (H3-oo = 23). HOA Keypad Display bb Minor Fault Name Anti-Jam Alarm Possible Solution • Check for proper pump operation. • Set the Anti-jam fault characteristics in P7-02 to P7-08. • Drive response to this condition is controlled by P7-01, Anti-jam Operation Selection. Minor Fault Name Baseblock Drive output interrupted as indicated by an external baseblock signal. Possible Solution Troubleshooting HOA Keypad Display Anti-Jam Active Cause The drive was not able to clear debris from the impeller in fewer than the attempts set in P7-02. This is only effective when P7-01, Anti-jam Operation is set to 1 (enabled). Cause External baseblock signal was entered via one of the multi-function input terminals Check external sequence and baseblock signal input timing. (S1 to S8). HOA Keypad Display boL Cause The proper braking resistor has not been installed. 5 Minor Fault Name Braking Transistor Overload Fault The braking transistor in the drive has been overloaded. Possible Solution Select the proper braking resistor. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 193 5.3 Alarm Detection HOA Keypad Display Minor Fault Name Option Communication Error bUS • The connection was lost after initial communication was established. • Assign a Run command frequency reference to the option. Cause Possible Solution • Check for faulty wiring. Connection is broken or master controller • Correct the wiring. stopped communicating. • Check for disconnected cables and short circuits. Repair as needed. Option is damaged. If there are no problems with the wiring and the fault continues to occur, replace the option. The option is not properly connected to the • The connector pins on the option are not properly lined up with the connector pins on the drive. drive. • Reinstall the option. • Check options available to minimize the effects of noise. • Take steps to counteract noise in the control circuit wiring, main circuit lines and ground wiring. • Try to reduce noise on the controller side. • Use surge absorbers on magnetic contactors or other equipment causing the disturbance. A data error occurred due to noise. • Use recommended cables or some other type of shielded line. Ground the shield to the controller side or on the input power side. • Separate the wiring for communication devices from the drive input power lines. Install an EMC noise filter to the drive input power. HOA Keypad Display Minor Fault Name Serial Communication Transmission Error Communication has not yet been established. Cause Possible Solution Communications wiring is faulty, there is a • Check for wiring errors. short circuit, or something is not connected • Correct the wiring. properly. • Check for disconnected cables and short circuits. Repair as needed. CALL Programming error on the master side. Communications circuitry is damaged. Termination resistor setting is incorrect. Check communications at start-up and correct programming errors. • Perform a self-diagnostics check. • If the problem continues, replace either the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or your nearest sales representative. Install a termination resistor at both ends of a communication line. Set the internal termination resistor switch correctly on slave drives. Place DIP switch S2 to the ON position. HOA Keypad Display Minor Fault Name MEMOBUS/Modbus Communication Error CE Control data was not received correctly for two seconds. Cause Possible Solution • Check options available to minimize the effects of noise. • Take steps to counteract noise in the control circuit wiring, main circuit lines, and ground wiring. • Reduce noise on the controller side. • Use surge absorbers for the magnetic contactors or other components that may be causing the disturbance. A data error occurred due to noise. • Use only recommended shielded line. Ground the shield on the controller side or on the drive input power side. • Separate all wiring for communication devices from drive input power lines. Install an EMC noise filter to the drive input power supply. • Check the H5 parameter settings and the protocol setting in the controller. Communication protocol is incompatible. • Ensure settings are compatible. • Check the PLC. The CE detection time (H5-09) is set shorter than the time required for a • Change the software settings in the PLC. communication cycle to take place. • Set a longer CE detection time using parameter H5-09. • Check the PLC. Incompatible PLC software settings or there is a hardware problem. • Remove the cause of the error on the controller side. Communications cable is disconnected or • Check the connector to make sure the cable has a signal. damaged. • Replace the communications cable. 194 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.3 Alarm Detection HOA Keypad Display CrST Cause Minor Fault Name Cannot Reset Possible Solution • Ensure that a Run command cannot be entered from the external terminals or option during fault reset. Fault reset was being executed when a Run command was entered. • Turn off the Run command. HOA Keypad Display dnE Cause “Drive Enable” is set to a multi-function contact input (H1-oo = 6A) and the contact is open. HOA Keypad Display EF Cause Minor Fault Name Drive Disabled Possible Solution Check the operation sequence. Minor Fault Name Forward/Reverse Run Command Input Error Both forward run and reverse run closed simultaneously for longer than 0.5 s. Possible Solution Check the forward and reverse command sequence and correct the problem. Sequence error Note: When minor fault EF detected, motor ramps to stop. HOA Keypad Display EF0 Minor Fault Name Option Card External Fault An external fault condition is present. Cause Possible Solution An external fault was received from the PLC with F6-03 set to 3, which allows the • Remove the cause of the external fault. drive to continue running after an external • Remove the external fault input from the PLC. fault occurs. There is a problem with the PLC program. Check the PLC program and correct problems. EF1 EF2 EF3 EF4 EF5 EF6 EF7 EF8 Cause An external device has tripped an alarm function. Wiring is incorrect. Multi-function contact inputs are set incorrectly. Minor Fault Name Pump Fault (Input Terminal S1) External fault at multi-function input terminal S1. Pump fault (input terminal S2) External fault at multi-function input terminal S2. Pump fault (input terminal S3) External fault at multi-function input terminal S3. Pump fault (input terminal S4) External fault at multi-function input terminal S4. Pump fault (input terminal S5) External fault at multi-function input terminal S5. Pump fault (input terminal S6) External fault at multi-function input terminal S6. Pump fault (input terminal S7) External fault at multi-function input terminal S7. Pump fault (input terminal S8) External fault at multi-function input terminal S8. Possible Solutions Troubleshooting HOA Keypad Display 5 Remove the cause of the external fault and reset the multi-function input value. • Ensure the signal lines have been connected properly to the terminals assigned for external fault detection (H1-oo = 2C to 2F). • Reconnect the signal line. • Check if the unused terminals have been set for H1-oo = 2C to 2F (External Fault). • Change the terminal settings. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 195 5.3 Alarm Detection HOA Keypad Display Minor Fault Name EoF Emergency Override Forward Run Cause Possible Solution The multi-function digital input for EmergOverrideFWD (H1-oo = AF) has Open H1-oo = AF if the emergency condition is no longer present been closed. HOA Keypad Display Eor Cause The multi-function digital input for EmergOverrideREV (H1-oo = B0) has been closed. Minor Fault Name Emergency Override Reverse Run Possible Solution Open H1-oo = B0 if the emergency condition is no longer present HOA Keypad Display Minor Fault Name PI Feedback Loss Feedback Loss Go To Freq. b5-13 The drive will run at the speed set in b5-13, Feedback Loss Goto Frequency. Cause Possible Solutions PI feedback source is incorrectly installed • Confirm that the PID feedback source is installed and working properly. or is not working. Effective only when • Drive response to this condition is controlled by b5-12, Feedback Loss 4 to 20 mA Detection Selection, b5-12 is set to 3 (Run at b5-13). and b5-13, Feedback Loss Go To Frequency. HOA Keypad Display Minor Fault Name PI Feedback Loss The analog input programmed for PID feedback has gone above 21 mA or fallen below 3 mA. Cause Possible Solutions • Confirm that the PID feedback source is installed and working properly. PI feedback source is incorrectly installed or is not working. This is effective only • Drive response to this condition is controlled by b5-12, Feedback Loss 4 to 20 mA Detection Selection, when b5-12 Feedback Loss 4 to 20 mA and b5-13, Feedback Loss Go To Frequency. Detection Selection is set to 1 (alarm). • Auto-restart of this fault is controlled by L5-42, Feedback Loss Fault Retry Selection. Feedback Loss Wire Break HOA Keypad Display Freq. Ref Pump Min (P1-06) Minor Fault Name Minimum Pump Frequency Reference Drive frequency reference is set lower than P1-06, Minimum Pump Frequency. Possible Solutions Cause The frequency reference is set lower than P1-06. The frequency reference is internally set to the P1-06 value during this time. This will only be active when the following Increase the frequency reference to a value greater than P1-06. conditions are true: • Drive is NOT in PI Mode • Minimum Pump Frequency is enabled (P1-06 > 0.00) HOA Keypad Display Freq. Ref Thrust (P4-12) Minor Fault Name Thrust Frequency Reference The fixed frequency reference is set to a value lower than the P4-12, Thrust Frequency, setting. Possible Solutions Cause The frequency reference is set lower than P4-12. The frequency reference is internally set to the P4-12 value during this time. This will only be active when the following Increase the frequency reference to a value greater than P4-12. conditions are true: • Drive is NOT in PI Mode • Thrust bearing is enabled (P4-12 > 0.00) HOA Keypad Display Geo Params Chk Q2-05 to Q2-08 196 Minor Fault Name Geothermal Mode Parameters The drive is running at the level set in Q2-03 due to an incorrect setting. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.3 Alarm Detection Cause The temperature parameter values are set incorrectly. Possible Solutions Set the temperature parameters in the following order: Q2-08 > Q2-07 > Q2-06 > Q2-05 HOA Keypad Display Minor Fault Name Current Alarm HCA Drive current exceeded overcurrent warning level (150% of the rated current). Cause Possible Solutions Load is too heavy. Reduce the load for applications with repetitive operations (i.e., stops and starts), or replace the drive. • Calculate the torque required during acceleration and for the inertia moment. Acceleration and deceleration times are too • If the torque level is not right for the load, take the following steps: short. • Increase the acceleration and deceleration times (C1-01 through C1-04). • Increase the capacity of the drive. A special-purpose motor is being used, or • Check the motor capacity. the drive is attempting to run a motor greater than the maximum allowable • Use a motor appropriate for the drive. Ensure the motor is within the allowable capacity range. capacity. The current level increased due to Speed The alarm will only appear briefly. There is no need to take action to prevent the alarm from occurring in Search after a momentary power loss or such instances. while attempting to perform a fault restart. HOA Keypad Display High Feedback High FB Sensed Minor Fault Name High Feedback Level Alarm The feedback signal is too high. Cause Possible Solutions The feedback level has risen above the level • Decrease the feedback signal. set in P1-11, High Feedback Level • Set the High Feedback alarm characteristics in P1-11 and P-12. This is only effective when P1-13, High Feedback Selection, is set to 1 (Alarm and • Drive response to this condition is controlled by P1-13, High Feedback Selection. digital out). HOA Keypad Display LOP Fault Name Loss of Prime The pump has lost its prime and P1-22 is set to 1. Possible Solution Cause The measured quantity of water has dropped below the level set in P1-19, Prime Loss Level, for the time set in P1-20, Loss of Prime Time, and the output frequency • If there is resistance in the pump, allow the system to pump water again. • Set the Loss of Prime alarm characteristics in P1-18, P1-19, P1-20, and P1-21. has risen above P1-21, Prime Loss Frequency. This could be due to a dry well, • Drive response to this condition is controlled by P1-21, Loss of Prime Selection. air in the system, or no water in the system. This is effective only when P1-22 Loss of Prime Selection is set to 1 (alarm). Minor Fault Name Troubleshooting HOA Keypad Display Low City Pressure Cause Low City Pressure Possible Solution • Check pressure switch contact for correct operation. Insufficient pressure is present on the inlet • Check control wiring to drive terminal strip from pressure switch contact. to the pump. • Check to make sure that suction pressure is present by means of a separate measuring device. HOA Keypad Display Low Feedback Low FB Sensed 5 Minor Fault Name Low Feedback Level Alarm The feedback signal is too low. Cause Possible Solutions The feedback level has dropped below the • Increase the feedback signal. level set in P1-08, Low Feedback Level • Set the Low Feedback alarm characteristics in P1-08 and P1-09. This is only effective when P1-10, Low Feedback Selection, is set to 1 (Alarm and • Drive response to this condition is controlled by P1-10, Low Feedback Selection. digital out). YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 197 5.3 Alarm Detection HOA Keypad Display Low Suction Pressure Cause Minor Fault Name Low Suction Pressure • • Insufficient suction pressure is present. • This is only effective when Q5-11, Low Suction Pressure Behavior Select is set to 1 • (alarm). • • HOA Keypad Display Low Water in Tank Cause Minor Fault Name Low Water in Tank • • The water level in the tank is too low. This • is only effective when Q4-11, Low Level • Behavior is set to 1 (alarm). • • HOA Keypad Display Low WL/SP Drive Disabled Possible Solution Check pressure switch contact for correct operation. Check control wiring to drive terminal strip from pressure switch contact. Check to make sure that suction pressure is present by means of a separate measuring device. Increase the system pressure. Set the Low Suction alarm characteristics in Q5-09, Q5-10, and Q5-18. Drive response to this condition is controlled by Q5-11, Low Suction Pressure Behavior Select. Possible Solution Check pressure switch contact for correct operation. Check control wiring to drive terminal strip from pressure switch contact. Check to make sure that suction pressure is present by means of a separate measuring device. Raise the water level. Set the Low Water Level alarm characteristics in Q4-09 and Q4-10. Drive response to this condition is controlled by Q4-11, Low Level Behavior. Fault Name Low Water Level / Suction Pressure Disabled Water Level or Suction Pressure is below the Q4-06/Q5-06 setting. Possible Solution Cause Drive is not allowed to run in MEMOBUS multiplex when P9-51 is set to 1, the Water • Confirm that the Water Level or Suction Pressure source is installed and working properly. Level or Suction Pressure is below the • Wait for the Water Level or Suction Pressure to recover. Q4-06/Q5-06 setting, and the drive is stopped or running as a lag drive. HOA Keypad Display LT-1 Cause The cooling fan has reached 90% of its expected performance life. HOA Keypad Display LT-2 Minor Fault Name Cooling Fan Maintenance Time The cooling fan has reached its expected maintenance period and may need to be replaced. Note: Replace the cooling fan and set o4-03 to 0 to reset the Maintenance Monitor. Minor Fault Name Capacitor Maintenance Time The main circuit and control circuit capacitors are nearing the end of their expected performance life. Note: Cause The main circuit and control circuit capacitors have reached 90% of their expected performance lives. HOA Keypad Display LT-3 An alarm output (H2-oo = 10) will only be triggered if both (H2-oo = 2F and H2-oo = 10) are set. Possible Solution An alarm output (H2-oo = 10) will only be triggered if H2-oo = 2F. Possible Solution Replace either the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or your nearest sales representative. Minor Fault Name Soft Charge Bypass Relay Maintenance Time The DC bus soft charge relay is nearing the end of its expected performance life. Note: An alarm output (H2-oo = 10) will only be triggered if H2-oo = 2F. Cause Possible Solution The DC bus soft charge relay has reached Replace either the control board or the entire drive. For instructions on replacing the control board, contact 90% of expected performance life. Yaskawa or your nearest sales representative. 198 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.3 Alarm Detection HOA Keypad Display LT-4 Minor Fault Name IGBT Maintenance Time (50%) IGBTs have reached 50% of their expected performance life. Note: An alarm output (H2-oo = 10) will only be triggered if H2-oo = 2F. Possible Solution Cause IGBTs have reached 50% of their expected Check the load, carrier frequency, and output frequency. performance life. HOA Keypad Display Net Flow Meter Lost, Chk Source Minor Fault Name Net Flow Meter Loss There is no drive on the MEMOBUS network with an analog flow meter. Possible Solution Cause When P1-01 = 3, P6-01 > 0, and P9-40 = 3, • Set P9-40 to 0 if the drive has an operational flow meter connected to an analog or pulse input terminal. the flow meter function has not received a valid flow rate from another drive that is • If another drive on the MEMOBUS network has a flow meter connected to an analog or pulse input terminal, confirm that drive is online with parameter settings P6-01 > 0 and P9-40 = 0. also running the flow meter function. HOA Keypad Display Minor Fault Name NETSCAN NETSCAN Waiting for Master Drive is waiting for a message from the master. Cause Possible Solution • Increase the P9-26 setting to account for network latency. No message was received from the master • Verify that there is a drive on the network with parameter P1-01 set to 3 and P9-27 to 0. within the time set in P9-28. • Check network connections and verify H5-01 and P9-25 settings for all drives on the network. HOA Keypad Display NMS Minor Fault Name Not Maintaining Setpoint The setpoint cannot be maintained and P1-17 is set to 1. Possible Solution Cause When the feedback deviates from the • Check for a blocked impeller, over cycling, or broken pipe. setpoint at a level greater than P1-15, for a • Set the Not Maintaining Setpoint alarm characteristics in P1-16 and P1-17. time set in P1-16. This is effective only • Drive response to this condition is controlled by P1-17, Not Maintaining Setpoint Selection. when P1-17 is set to 1 (alarm). oH Cause Surrounding temperature is too high Internal cooling fan has stopped. Airflow around the drive is restricted. Minor Fault Name Heatsink Overheat The temperature of the heatsink exceeded the overheat pre-alarm level set to L8-02. Possible Solution • Check the surrounding temperature. • Improve the air circulation within the enclosure panel. • Install a fan or air conditioner to cool surrounding area. • Remove anything near drive that may cause extra heat. • Replace the cooling fan. • After replacing the drive, set parameter o4-03 to 0 to reset the cooling fan operation time. • Provide proper installation space around the drive as indicated in the manual. Refer to Installation Orientation and Spacing on page 34 for details. • Allow for the proper space and ensure that there is sufficient circulation around the control panel. • Check for dust or other foreign materials clogging the cooling fan. • Clear debris caught in the fan that restricts air circulation. HOA Keypad Display oH2 Cause An external device triggered an overheat warning in the drive. Troubleshooting HOA Keypad Display 5 Minor Fault Name Drive Overheat Warning “Drive Overheat Warning” was input to a multi-function input terminal, S1 through S8 (H1-oo= B). Possible Solution Search for the device that tripped the overheat warning. Remove the cause of the problem. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 199 5.3 Alarm Detection HOA Keypad Display oH3 Cause Motor thermostat wiring is faulty (PTC input). There is a fault on the machine side (e.g., the machine is locked up). Minor Fault Name Motor Overheat The motor overheat signal entered to a multi-function analog input terminal exceeded the alarm level (H3-02, H3-06 or H3-10 = E). Possible Solutions Repair the PTC input wiring. • • • • • • Note: Motor has overheated. • • • • HOA Keypad Display oH4 Cause Motor has overheated ov Cause Surge voltage present in the drive input power. Refrain from lowering E1-08 and E1-10 excessively to prevent a reduction in load tolerance at low speeds. Check the motor-rated current. Enter motor-rated current on motor nameplate (E2-01). Ensure the motor cooling system is operating normally. Repair or replace the motor cooling system. Fault Name Motor Overheat Fault (PTC Input) • The motor overheat signal to analog input terminal A1, A2, or A3 exceeded the fault detection level. • Detection requires setting multi-function analog inputs H3-02, H3-10, or H3-06 to E. Possible Solution • Check the size of the load, the accel/decel times, and the cycle times. • Decrease the load. • Increase the acceleration and deceleration times (C1-01 through C1-04). • Adjust the preset V/f pattern (E1-04 through E1-10) by reducing E1-08 and E1-10. • Do not set E1-08 and E1-10 too low. This reduces load tolerance at low speeds. • • • • HOA Keypad Display Check the status of the machine. Remove the cause of the fault. Check the load size, accel/decel times, and cycle times. Decrease the load. Increase accel and decel times (C1-01 to C1-04). Adjust the preset V/f pattern (E1-04 through E1-10). This involves reducing E1-08 and E1-10. Check the motor rated current. Enter the motor rated current to parameter E2-01 as indicated on the motor nameplate. Ensure the motor cooling system is operating normally. Repair or replace the motor cooling system. Minor Fault Name DC Bus Overvoltage The DC bus voltage exceeded the trip point. • For 200 V class drives: approximately 410 V • For 400 V class drives: approximately 820 V (740 V when E1-01 is less than 400) • For 600 V class drives: approximately 1040 V Possible Solutions • Install a DC link choke or an AC reactor. • Voltage surge can result from a thyristor convertor and a phase advancing capacitor operating on the same drive input power system. The motor is short-circuited. • Check the motor power cable, relay terminals and motor terminal box for short circuits. Ground current has overcharged the main • Correct grounding shorts and turn the power back on. circuit capacitors via the drive input power. • Review possible solutions for handling noise interference. • Review section on handling noise interference and check control circuit lines, main circuit lines and ground Noise interference causes the drive to wiring. operate incorrectly. • If the magnetic contactor is identified as a source of noise, install a surge protector to the MC coil. Set number of fault restarts (L5-01) to a value other than 0. HOA Keypad Display PASS Cause 200 Minor Fault Name MEMOBUS/Modbus Comm. Test Mode Complete Possible Solution YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.3 Alarm Detection MEMOBUS/Modbus test has finished normally. This verifies that the test was successful. HOA Keypad Display Minor Fault Name PoC Pump Over Cycle Cause Possible Solution The pump has exceeded the number of • Set the Pump Over Cycle alarm characteristics in P2-10 and P2-11. cycles set in P2-10 in the time set in P2-11 • Drive response to this condition is controlled by P2-12, Over Cycling Mode. and P2-12 is set to 1 (alarm). HOA Keypad Display R-DNE-So Cause Minor Fault Name Remote Drive Disable Possible Solution Terminal So (H1-0o = 95) has been closed for the time set in P4-26, Remote Remove conditions causing the terminal to close. Drive Disable On-Delay, when P4-25, Remote Drive Disable Selection, was set to 0 (N.O.). Terminal So (H1-0o = 95) has been open for the time set in P4-26, Remote Drive Disable On-Delay, when P4-25, Remote Remove conditions causing the terminal to open. Drive Disable Selection, was set to 1 (N.C.). HOA Keypad Display rUn Cause A motor switch command was entered during run. HOA Keypad Display SE Cause A digital input set to 67H (MEMOBUS/ Modbus test) was closed while the drive was running. Minor Fault Name Motor Switch during Run A command to switch motors was entered during run. Possible Solution Change the operation pattern so that the motor switch command is entered while the drive is stopped. Minor Fault Name MEMOBUS/Modbus Communication Test Mode Error Note: This alarm will not trigger a multi-function output terminal that is set for alarm output (H2-oo = 10). Possible Solution Stop the drive and run the test again. HOA Keypad Display Temperature Lost Geothermal Input Minor Fault Name Temperature Lost Geothermal Input The geothermal input is not present. Troubleshooting Cause Possible Solution The input signal level has dropped below 3 mA or risen above 21 mA and b1-01 = 5, Confirm that the device connected to the analog input terminal is installed and working properly. H3-0o = 21 (Geothermal Input), H3-0o = 2 (4 to 20 mA), and Q2-09 = 1 (Alarm). Parameter b1-01 = 5, H3-0o≠ 21 Assign one of the analog inputs to “Geothermal Temperature”, H3-0o = 21. (Geothermal Temp), and Q2-09 = 1 (Alarm). The input signal level has dropped below 3 mA or risen above 21 mA when the drive was in HAND Mode or had no Run Confirm that the device connected to the analog input terminal is installed and working properly. command and b1-01 = 5, H3-0o = 21 (Geothermal Input), H3-0o = 2 (4 to 20 mA), and Q2-09 = 1 (Alarm). HOA Keypad Display TrPC Cause 5 Minor Fault Name IGBT Maintenance Time (90%) IGBTs have reached 90% of their expected performance life. Possible Solution YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 201 5.3 Alarm Detection IGBTs have reached 90% of their expected Replace the drive. performance life. HOA Keypad Display Uv Cause Phase loss in the drive input power. Loose wiring in the drive input power terminals. There is a problem with the drive input power voltage. Drive internal circuitry is worn. The drive input power transformer is too small and voltage drops when the power is switched on. Air inside the drive is too hot. The CHARGE light is broken or disconnected. Minor Fault Name Undervoltage One of the following conditions was true when the drive was stopped and a Run command was entered: • DC bus voltage dropped below the level specified in L2-05. • Contactor to suppress inrush current in the drive was opened. • Low voltage in the control drive input power. This alarm outputs only if L2-01 is not 0 and DC bus voltage is under L2-05. Possible Solution Check for wiring errors in the main circuit drive input power. Correct the wiring. • Ensure the terminals have been properly tightened. • Apply the tightening torque to the terminals as specified. Refer to Wire Gauges and Tightening Torque on page 87. • Check the voltage. • Lower the voltage of the drive input power so that it is within the limits listed in the specifications. • Check the maintenance time for the capacitors (U4-05). • Replace either the control board or the entire drive if U4-05 exceeds 90%. For instructions on replacing the control board, contact Yaskawa or your nearest sales representative. • Check for an alarm when the magnetic contactor, line breaker, and leakage breaker are closed. • Check the capacity of the drive input power transformer. Check the temperature inside the drive. Replace either the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or your nearest sales representative. HOA Keypad Display Minor Fault Name WrUn Waiting for Run Cause Possible Solutions The Run command has been applied and the Adjust b1-11 to the desired delay time. The drive sill start normally after the b1-11 timer expires. b1-11 timer is active. 202 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.4 Operator Programming Errors 5.4 Operator Programming Errors u Operator Programming Error Codes, Causes, and Possible Solutions An Operator Programming Error (oPE) occurs when a contradictory parameter is set or an individual parameter is set to an inappropriate value. The drive will not operate until the parameter or parameters causing the problem are set correctly. An oPE, however, does not trigger an alarm or fault output. If an oPE occurs, investigate the cause and refer to Table 5.4 for the appropriate action. When an oPE appears on the operator display, press the ENTER button to view U1-18 and see which parameter is causing the oPE. Table 5.4 oPE Codes, Causes, and Possible Solutions HOA Keypad Display oPE01 Error Name Drive Capacity Setting Fault Drive capacity and the value set to o2-04 do not match. Possible Solutions Cause The drive model selection (o2-04) and the actual Correct the value set to o2-04. capacity of the drive are not the same. HOA Keypad Display oPE02 Cause Parameters were set outside the possible setting range. Note: Error Name Parameter Range Setting Error Use U1-18 to find parameters set outside the range. Possible Solutions Set parameters to the proper values. When multiple errors occur simultaneously, other errors are given precedence over oPE02. HOA Keypad Display oPE03 Cause • The same function is assigned to two multi-function inputs. • Excludes “Not used” and “External Fault.” Error Name Multi-Function Input Selection Error A contradictory setting is assigned to multi-function contact inputs H1-01 to H1-08. Possible Solutions • Ensure all multi-function inputs are assigned to different functions. • Re-enter the multi-function settings to ensure this does not occur. The Up command was set but the Down command was not, or vice versa (settings 10 vs. 11). Properly set the functions that required for use in combination with other functions. Properly set the functions that required for use in combination with other functions. • Check if contradictory settings have simultaneously been assigned to the multi-function input terminals. • Correct setting errors. Set b5-01 to 0 to disable control PID or disable the Up/Down command. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 203 Troubleshooting The Up 2 command was set but the Down 2 command was not, or vice versa (settings 75 vs. 76). • Run/Stop command for a 2-wire sequence was set (H1-oo = 42), but Forward/Reverse command (H1-oo = 43) was not. • “Drive Enable” is set to multi-function input S1 or S2 (H1-01 = 6A or H1-02 = 6A). Two of the following functions are set simultaneously: • Up/Down Command (10 vs. 11) • Up 2/Down 2 Command (75 vs. 76) • Hold Accel/Decel Stop (A) • Analog Frequency Reference Sample/Hold (1E) • Offset Frequency 1, 2, 3 Calculations (44, 45, 46) The Up/Down command (10, 11) and PID control (b5-01) are enabled simultaneously. 5 5.4 Operator Programming Errors Settings for N.C. and N.O. input for the following functions were selected simultaneously: • External Search Command 1 and External Search Command 2 (61 vs. 62) • Fast Stop N.O. and Fast Stop N.C. (15 vs. 17) • KEB for Momentary Power Loss and High Slip Braking (65, 66, 7A, 7B vs. 68) • Check if contradictory settings have simultaneously been assigned to the multi-function input • Motor Switch Command and Accel/Decel Time terminals. 2 (16 vs. 1A) • Correct setting errors. • KEB Command 1 and KEB Command 2 (65, 66 vs. 7A, 7B) • FWD Run Command (or REV) and FWD/REV Run Command (2-wire) (40, 41 vs. 42, 43) • External DB Command and Drive Enable (60 vs. 6A) • Motor Switch Command and Up 2/Down 2 Command (16 vs. 75, 76) One of the following settings was entered while H1-oo = 2 (External Reference 1/2): • b1-15 = 4 (Pulse Train Input) but the pulse train input selection is not set for the frequency reference (H6-01 > 0) • b1-15 or b1-16 set to 3 but no option card is Correct the settings for the multi-function input terminal parameters. connected • Although b1-15 = 1 (Analog Input) and H3-02 or H3-10 are set to 0 (Frequency Bias) H2-oo is set to 38 (Drive Enabled) and H1-oo is not set to 6A (Drive Enable). HOA Keypad Display Error Name oPE04 Initialization Required, Term <–> Ctrl Chg Cause Possible Solutions The drive, control board, or terminal board have been replaced and the parameter settings between Set A1-03 to 5550 to load the parameter settings stored in the terminal board to the drive. Initialize the control board and the terminal board no longer parameters after drive replacement by setting A1-03 to 1110 or 2220. match. HOA Keypad Display Error Name oPE05 Run Command/Frequency Reference Source Selection Error Cause Possible Solutions Frequency reference is assigned to an option card (b1-01 = 3) and an input option card is not connected to the drive. Reconnect the input option card to the drive. The Run command is assigned to an option card (b1-02 = 3) and an input option card is not connected to the drive. Frequency reference is assigned to the pulse train Set H6-01 to 0. input (b1-01 = 4) and terminal RP is not set for frequency reference input (H6-01 > 0) HOA Keypad Display oPE07 Cause At least two analog input terminals are set to the same function (i.e., at least two of these parameters have the same setting: H3-02, H3-10, or H3-06). 204 Error Name Multi-Function Analog Input Selection Error A contradictory setting is assigned to multi-function analog inputs H3-02, H3-10, or H3-06 and PID functions conflict. Possible Solutions Change the settings to H3-02, H3-10, and H3-06 so that functions no longer conflict. Note: Both 0 (Frequency Reference Bias) and F (Not Used) can be set to H3-02, H3-10, or H3-06 simultaneously. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.4 Operator Programming Errors The following simultaneous contradictory settings: • H3-02, H3-10, or H3-06 = B (PID Feedback) while H6-01 (Pulse Train Input) = 1 (PID Feedback) • H3-02, H3-10, or H3-06 = C (PID Target Value) Disable one of the PID selections. while H6-01 = 2 (pulse train input sets the PID target value) • H3-02, H3-10, or H3-06 = C (PID Target Value) while b5-18 = 1 (enables b5-19 as the target PID value) • H6-01 = 2 (PID target) while b5-18 = 1 (enables b5-19 as the target PID value) HOA Keypad Display oPE09 Cause The following simultaneous contradictory settings have occurred: • b5-15 is not set to 0.0 (PID Sleep Function Operation Level) • The stopping method is set to either DC Injection Braking or coast to stop with a timer (b1-03 = 2 or 3). b5-01 is set to 1 or 2, enabling PID control, but the lower limit for the frequency reference (d2-02) is not set to 0 while reverse output is enabled (b5-11 = 1). b5-01 is set to 3 or 4, enabling PID control, but the lower limit for the frequency reference (d2-01) is not 0. HOA Keypad Display oPE10 Cause V/f pattern setting error. HOA Keypad Display oPE11 Error Name PID Control Selection Fault PID control function selection is incorrect. Requires that PID control is enabled (b5-01 = 1 to 4). Possible Solutions • Set b5-15 to a value other than 0.0. • Set the stopping method to coast to stop or ramp to stop (b1-03 = 0 or 1). Correct the parameter settings. Correct the parameter settings. Error Name V/f Data Setting Error One of the following setting errors has occurred: E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04 Possible Solutions Correct the settings for E1-04, E1-06, E1-07, E1-09, and E1-11. Error Name Carrier Frequency Setting Error Correct the setting for the carrier frequency. Possible Solutions HOA Keypad Display oPE28 Troubleshooting Cause The following simultaneous contradictory settings have occurred: C6-05 > 6 and C6-04 > C6-03 (carrier frequency lower limit is greater than the upper limit). Correct the parameter settings. If C6-05 ≤ 6, the drive operates at C6-03. The upper and lower limits between C6-02 and C6-05 are contradictory. Error Name Sequence Timer Error One or more of the sequence timers is not set in the correct order. Possible Solutions 5 Cause One of the following contradictory settings is true: • S2-01 > S2-02 Correct the parameter settings. • S2-06 > S2-07 • S2-11 > S2-12 • S2-16 > S2-17 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 205 5.4 Operator Programming Errors HOA Keypad Display Error Name oPE29 Geothermal Set Error Cause Possible Solutions P1-01 parameter selection is not compatible with Confirm b1-01 and P1-01 parameter settings. Geothermal Mode (b1-01 = 5). HOA Keypad Display Error Name oPE30 Flow Meter Input Error Cause Possible Solutions Analog and pulse flow meters are programmed simultaneously. Reprogram H6-01, H3-02, H3-06, or H3-10. H6-01 is set to 5 and either H3-02, H3-06, or H3-10 is set to 22. Flow meter scaling is set to 0 and the flow meter is being used as PID feedback. Reprogram P6-01, P1-02, or b5-01. P6-01 is set to 0.0, P1-02 is set to 25 and b5-01 is set to a value higher than 0. HOA Keypad Display oPE31 Water Level/Suction Cause Both Q4-01, Water Level Selection, and Q5-01, Reprogram Q4-01 or Q5-01. Suction Pressure Select, are set to a non-zero value. Error Name Possible Solutions HOA Keypad Display Error Name oPE32 Incompatible Network Water Level/Suction Pressure Mode Cause Possible Solutions Low Water Level or Suction Pressure Turn-Off Method (P9-51) is restricted to Water Level Source Confirm parameter settings for P9-50 and P9-51. of Analog Only (P9-50 = 0). HOA Keypad Display Error Name oPE33 Parameter selection is incompatible with the selected network P9-99 Cause Possible Solutions When P1-01 = 3 (MEMOBUS Networking) and P9-99 = 0 (A-Version 30034), one of the following parameters has been set: • P9-01 = 2 (Stop History) • P9-05 = 3 (Follow Lead Speed) Confirm parameter settings for P1-01, P9-99, P6-01, P9-05, P9-40, Q4-01, and Q5-01. • Q4-01 > 0 (Water Level Enabled) • Q5-01 > 0 (Suction Pressure Control Enabled) • P6-01 > 0 (Flow Meter Enabled) and P9-40 = 3 (Network) 206 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.5 Auto-Tuning Fault Detection 5.5 Auto-Tuning Fault Detection When the Auto-Tuning faults shown below are detected, the fault is displayed on the HOA keypad and the motor coasts to a stop. Auto-Tuning faults do not trigger a multi-function terminal set for fault or alarm output. An Endo error indicates that although Auto-Tuning has successfully completed, there is some discrepancy in the calculations. If an Endo error occurs, check for the cause of the error using the table in this section, and perform Auto-Tuning again or manually set the motor parameters after fixing the problem. Start the application if no problem can be diagnosed despite the existence of the Endo error. u Auto-Tuning Codes, Causes, and Possible Solutions Table 5.5 Auto-Tuning Codes, Causes, and Possible Solutions HOA Keypad Display Error Name Excessive V/f Setting (detected only during Rotational Auto-Tuning and displayed after Auto-Tuning End1 is complete) Cause Possible Solutions The torque reference exceeded 20% during • Prior to Auto-Tuning, verify the information on the motor nameplate. Auto-Tuning. • Enter proper values from motor nameplate to parameters T1-02 and T1-04 and repeat Auto-Tuning. The results from Auto-Tuning the no-load current • If possible, disconnect the motor from the load and perform Auto-Tuning. If the load cannot be exceeded 80%. uncoupled, use the current Auto-Tuning results. End2 Cause Motor data entered during Auto-Tuning was incorrect. Results from Auto-Tuning are outside the parameter setting range, assigning the iron-core saturation coefficients (E2-07 and E2-08) to temporary values. HOA Keypad Display End3 Cause The correct current rating printed on the motor nameplate was not entered into T1-04. Error Name Motor Iron-Core Saturation Coefficient (detected only during Rotational Auto-Tuning and displayed after Auto-Tuning is complete) Possible Solutions • Make sure the data entered to the T1 parameters match the information written on the motor nameplate. • Restart Auto-Tuning and enter the correct information. • Check and correct faulty motor wiring. • Disconnect the motor from machine and perform Rotational Auto-Tuning. Error Name Rated Current Setting Alarm (displayed after Auto-Tuning is complete) Possible Solutions • Check the setting of parameter T1-04. • Check the motor data and repeat Auto-Tuning. HOA Keypad Display End4 Cause Error Name Adjusted Slip Calculation Error HOA Keypad Display End5 Cause Resistance Tuning Error Possible Solutions • Make sure the data entered for Auto-Tuning is correct. The calculated slip is outside the allowable range. • If possible, perform Rotational Auto-Tuning. If not possible, perform Stationary Auto-Tuning 2. The calculated resistance value is outside the allowable range. Error Name Possible Solutions • Double-check the data entered for the Auto-Tuning process. • Check the motor and motor cable connection for faults. 5 HOA Keypad Display Error Name End6 Leakage Inductance Alarm Cause Possible Solutions The calculated leakage inductance value is outside Double-check the data entered for the Auto-Tuning process. the allowable range. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Troubleshooting HOA Keypad Display 207 5.5 Auto-Tuning Fault Detection HOA Keypad Display Error Name End7 No-Load Current Alarm Cause Possible Solutions The entered no-load current value was outside the Check and correct faulty motor wiring. allowable range. Auto-Tuning results were less than 5% of the Double-check the data entered for the Auto-Tuning process. motor rated current. HOA Keypad Display Er-01 Cause Error Name Motor Data Error Possible Solutions • Check that the motor data entered to T1 parameters matches motor nameplate input before AutoMotor data or data entered during Auto-Tuning Tuning. was incorrect . • Restart Auto-Tuning and enter the correct information. • Check the drive and motor capacities. Motor output power and motor-rated current settings (T1-02 and T1-04) do not match. • Correct the settings of parameters T1-02 and T1-04. Motor rated current and detected no-load current • Check the motor rated current and no-load current. are inconsistent. • Correct the settings of parameters T1-04 and E2-03. HOA Keypad Display Er-02 Cause An alarm was triggered during Auto-Tuning. Error Name Minor Fault Possible Solutions Exit the Auto-Tuning menu, check the alarm code, remove the alarm cause, and repeat Auto-Tuning. HOA Keypad Display Error Name Er-03 STOP Button Input Cause Possible Solutions Auto-Tuning canceled by pressing STOP button. Auto-Tuning did not complete properly. Restart Auto-Tuning. HOA Keypad Display Er-04 Cause Motor data entered during Auto-Tuning was incorrect. Error Name Line-to-Line Resistance Error Possible Solutions • Make sure the data entered to the T1 parameters match the information written on the motor nameplate. • Restart Auto-Tuning and enter the correct information. Results from Auto-Tuning are outside the parameter setting range or the tuning process took Check and correct faulty motor wiring. too long. Faulty motor cable or cable connection. HOA Keypad Display Er-05 Cause Motor data entered during Auto-Tuning was incorrect. Error Name No-Load Current Error Possible Solutions • Make sure the data entered to the T1 parameters match the information written on the motor nameplate. • Restart Auto-Tuning and enter the correct information. Results from Auto-Tuning are outside the • Check and correct faulty motor wiring. parameter setting range or the tuning process took • Perform Rotational Auto-Tuning. too long. • Disconnect the motor from machine and restart Auto-Tuning. If motor and load cannot be The load was too high during Rotational Autouncoupled make sure the load is lower than 30%. tuning. • If a mechanical brake is installed, make sure it is fully lifted during tuning. 208 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.5 Auto-Tuning Fault Detection HOA Keypad Display Er-08 Cause Motor data entered during Auto-Tuning was incorrect. Error Name Rated Slip Error Possible Solutions • Make sure the data entered to the T1 parameters match the information written on the motor nameplate. • Restart Auto-Tuning and enter the correct information. Results from Auto-Tuning are outside the • Check and correct faulty motor wiring. parameter setting range or the tuning process took • Perform Rotational Auto-Tuning. too long. • Disconnect the motor from machine and restart Auto-Tuning. If motor and load cannot be The load was too high during rotational Autouncoupled make sure the load is lower than 30%. tuning. • If a mechanical brake is installed, make sure it is fully lifted during tuning. Error Name Acceleration Error The motor did not accelerate for the specified acceleration time. Possible Solutions • Increase the acceleration time (C1-01). • Disconnect the machine from the motor if possible. Torque limit when motoring is too low (L7-01 and L7-02) • Check L7-01 and L7-02 settings. • Increase the setting. The load was too high during Rotational AutoTuning. • Disconnect the motor from machine and restart Auto-Tuning. If motor and load cannot be uncoupled make sure the load is lower than 30%. • If a mechanical brake is installed, make sure it is fully lifted during tuning. HOA Keypad Display Er-11 Cause Torque reference is too high. HOA Keypad Display Er-12 Cause One of the motor phases is missing: (U/T1, V/T2, W/T3). The current exceeded the current rating of the drive. The current is too low. Error Name Motor Speed Fault Possible Solutions • Increase the acceleration time (C1-01). • Disconnect the machine from the motor if possible. Error Name Current Detection Error Possible Solutions Check motor wiring and correct any problems. • Check motor wiring for a short between motor lines. • Close any magnetic contactors used between motors. • Replace the control board or the entire drive. For instructions on replacing the control board, contact Yaskawa or your nearest sales representative. Attempted Auto-Tuning without motor connected Connect the motor and restart Auto-Tuning. to the drive. Replace the control board or the entire drive. For instructions on replacing the control board, contact Current detection signal error. Yaskawa or your nearest sales representative. HOA Keypad Display Er-13 Cause Error Name Leakage Inductance Error Possible Solutions • Check all wiring and correct any mistakes. Drive was unable to complete tuning for leakage • Check the motor rated current value written on the motor nameplate and enter the correct value to inductance within 300 seconds. T1-04. HOA Keypad Display Er-17 Error Name Reverse Prohibited Error Cause YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Possible Solutions 209 Troubleshooting HOA Keypad Display Er-09 Cause 5 5.5 Auto-Tuning Fault Detection Drive is prohibited from rotating the motor in reverse while attempting to perform Inertia Tuning. 210 • Inertia Auto-Tuning cannot be performed if the drive is restricted from rotating in reverse. • Assuming it is acceptable for the application to rotate in reverse, set b1-04 to 0 and then perform Inertia Tuning. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.6 Copy Function Related Displays 5.6 Copy Function Related Displays u Tasks, Errors, and Troubleshooting The table below lists the messages and errors that may appear when using the Copy function. When executing the tasks offered by the Copy function, the keypad will indicate the task being performed. When an error occurs, a code appears on the keypad to indicate the error. Note that errors related to the Copy function do not trigger a multifunction output terminal that has been set up to close when a fault or alarm occurs. To clear an error, simply press any key on the keypad and the error display will disappear. Table 5.6 lists the corrective action that can be taken when an error occurs. Note: 1. Whenever using the copy function, the drive should be fully stopped. 2. The drive will not accept a Run command while the Copy function is being executed. 3. Parameters can only be saved to a drive when the voltage class, capacity, control mode, and software version match. Table 5.6 Copy Function Task and Error Displays HOA Keypad Display CoPy Cause Parameters are being written to the drive. HOA Keypad Display CPyE Cause Failed writing parameters HOA Keypad Display CSEr Cause Hardware fault Task Writing Parameter Settings (flashing) Possible Solutions This is not an error. Task Error Writing Data Possible Solutions Attempt to write parameters again. Task Copy Unit Error Possible Solutions Replace the HOA keypad or the USB Copy Unit. HOA Keypad Display Task dFPS Drive Model Mismatch Cause Possible Solutions The drives used in the copy and write process are not the same model. • Verify the model number of the drive from which the parameters were copied and the model of the drive to which those parameters will be written. • The drive from which the parameters were copied is a different model. • Make sure the two drives are the same model and have the same software version. • The drive to be written to is a different model. Task Troubleshooting HOA Keypad Display End Task Complete Cause Finished reading, writing, or verifying parameters. This is not an error. Possible Solutions HOA Keypad Display Task iFEr Communication Error Cause Possible Solutions A communication error occurred between the drive Check the cable connection. and the HOA keypad or the USB copy unit. A non-compatible cable is being used to connect Use the cable originally packaged with the USB Copy Unit. the USB Copy Unit and the drive. HOA Keypad Display ndAT Cause 5 Task Model, Voltage Class, Capacity Mismatch Possible Solutions YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 211 5.6 Copy Function Related Displays The drive from which the parameters were copied and the drive to which the parameters will be Make sure model numbers and specifications are the same for both drives. written have different electrical specifications, capacities, are set to different control modes, or are different models. The device being used to write the parameters is Make sure all connections are correct, and copy the parameter settings onto the USB Copy Unit or blank and does not have any parameters saved on the HOA keypad. it. HOA Keypad Display Task rdEr Error Reading Data Cause Possible Solutions Failed while attempting to read parameter settings Press and hold the READ key on the USB Copy Unit for at least one second to have the unit read from the drive. parameters from the drive. HOA Keypad Display Task rEAd Reading Parameter Settings (flashing) Cause Possible Solutions Displayed while the parameter settings are being This is not an error. read onto the USB Copy Unit. HOA Keypad Display Task vAEr Voltage Class, Capacity Mismatch Cause Possible Solutions The drive from which the parameters were copied and the drive on which the Verify mode is being Make sure electrical specifications and capacities are the same for both drives. performed have different electrical specifications or are a different capacity. HOA Keypad Display vFyE Cause Indicates that parameter settings that have been Read and loaded onto the Copy Unit or HOA keypad are different. Task Parameter settings in the drive and those saved to the copy function are not the same Possible Solutions HOA Keypad Display vrFy Cause The Verify mode has confirmed that parameters settings on the drive and parameters read to the copy device are identical. Task Comparing Parameter Settings (flashing) Possible Solutions 212 To synchronize parameters, either write the parameters saved on the USB Copy Unit or HOA keypad onto the drive, or Read the parameter settings on the drive onto the USB Copy Unit. This is not an error. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.7 HOA Keypad Display Messages 5.7 HOA Keypad Display Messages The table below lists messages and errors that may appear during normal pump operation. These messages do not trigger multi-function output terminals that have been set up to close when a fault or alarm occurs. Table 5.7 HOA Keypad Display Messages Start Delay Timer Active Sleep Active Wait for Start Sleep Boost Active Start Delay Adjust b1-11 Feedback Drop Check Description Displayed when the feedback level has reached the level set in P1-04, Start Level, and the Start Delay timer is incrementing. Displayed when the drive is in Sleep Mode or when the drive is waiting for the feedback level to reach the level set in P1-04, Start Level. Displayed when the drive entering Sleep Mode and the pressure setpoint is being boosted. During this time, the U1-01, Frequency Reference, monitor will be updated with the boosted setpoint. Displayed when the drive start is being delayed by Coast to Stop with Timer. This time is adjusted by parameter b1-11, Coast to Stop with Timer Time. Displayed when the drive is determining whether the feedback will change abruptly when the drive enters Sleep Mode. Drop Level is configured by P2-08, Delta Sleep Feedback Drop Level, and P2-09 Feedback Detection Drop Time. Pre Chg Mode Pre-chy Active Displayed during Pre-Charge Mode. Thrust Mode Thrust Active Displayed during Thrust Mode. Utility Delay Adjust by P4-17 Lube Pump Active LOCK Parameter Locked Displayed when the drive is delaying the Run command due to the Utility Start Delay Function. Displayed when the drive is delaying the start of the motor and the Lube Pump digital output is energized. Anti Jam Active Sleep Active Min Water Level Displayed when the drive is performing the anti-jam function. Displayed when the drive has gone to sleep because the water level has dropped below the level set in Q4-04 for longer than the time set in Q4-05. Sleep Active Min Suction Pres Displayed when the drive has gone to sleep because the suction level has dropped below the level set in Q5-04 for longer than the time set in Q5-05. Net Start Delay P9-29 Active Displayed when the MEMOBUS network is waiting for the P9-29 timer to elapse. Network FB Lost Check FB Source Displayed when no valid analog PI feedback source can be found on the network and network PI feedback has been lost. Net Pump Err Chk Faulted Pump Displayed when the drive has been stopped because another drive in the network has a system fault or a Low City Pressure alarm. Net Water Level or Suction Lost Displayed when the network source for Water Level or Suction Control Pressure has been lost. Net Geothm Tmp Lost, Chk Source Displayed when no valid analog Geothermal Temperature source can be found on the network. Displayed after an attempt to change a parameter when A1-01 = 3. Unlock the keypad by setting A1-01 = 2. u Fault Reset Methods When a fault occurs, the cause of the fault must be removed and the drive must be restarted. The table below lists the different ways to restart the drive. After the Fault Occurs Procedure ALM DIGITAL OPERATOR JVOP-183 -Rdy- -DRIVE- Fix the cause of the fault, restart the drive, and Press reset the fault Freq Ref (OPR) U1- 01=60.00Hz F1 F2 M M ESC HAND RESET ENTER AUTO Resetting via a multi-function digital input programmed for Fault Reset (H1-oo = 14). 5 ---------------- U1- 02=60.00Hz JOG FWD FWD/REV on the HOA keypad. For example, close then open the fault signal digital input via terminal S4. S4 is set for “Fault Reset” as default (H1-04 = 14). YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide OFF Drive Fault Reset Switch Troubleshooting HOA Keypad Display S4 Fault Reset Digital Input SC Digital Input Common 213 5.7 HOA Keypad Display Messages After the Fault Occurs Procedure Turn off the main power supply if the above methods do not reset the fault. Reapply power after the HOA keypad display has turned off. When an “SC” error occurs, contact Yaskawa or a Yaskawa agent before cycling the power to the drive. Note: 214 2 ON 1 OFF If the Run command is present, the drive will disregard any attempts to reset the fault. Remove the Run command before attempting to clear a fault situation. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.8 Auto-Tuning 5.8 Auto-Tuning u Types of Auto-Tuning The drive offers different types of Auto-Tuning for induction motors. Refer to the tables below to select the type of AutoTuning that bests suits the application. n Auto-Tuning for Induction Motors This feature automatically sets the V/f pattern and motor parameters E1-oo and E2-oo for an induction motor. Table 5.8 Types of Auto-Tuning for Induction Motors Type Stationary Auto-Tuning for Line-to-Line Resistance Rotational Auto-Tuning for V/f Control Stationary Auto-Tuning 2 Control Mode V/f OLV Setting Application Conditions and Benefits T1-01 = 2 • The drive is used in V/f Control and other Auto-Tuning selections are not possible. • Perform when entering motor data manually while using motor cables longer than 50 m. • Drive and motor capacities differ. • Tunes the drive after the cable between the drive and motor has been replaced with a cable over 50 m long. Assumes Auto-Tuning has already been performed. • Should not be used for any vector control modes unless the motor cable has changed. YES YES T1-01 = 3 • Recommended for applications using Speed Estimation Speed Search or using the Energy Saving function in V/f Control. • Assumes motor can rotate while Auto-Tuning is executed. Increases accuracy for certain functions like torque compensation, slip compensation, Energy Saving, and Speed Search. YES – T1-01 = 4 • Motor and load cannot be decoupled and the load is higher than 30%. • A motor test report is available. After entering the no-load current and the rated slip, the drive calculates and sets all other motor-related parameters. – YES Table 5.9 lists the data that must be entered for Auto-Tuning. Make sure this data is available before starting Auto-Tuning. The necessary information is usually listed on the motor nameplate or in the motor test report provided by the motor manufacturer. Table 5.9 Auto-Tuning Input Data Control Mode Motor rated power Motor rated voltage Motor rated current Motor rated frequency Number of motor poles Motor rated speed Motor no-load current Motor rated slip Motor iron loss Input Parameter Unit A1-02 T1-02 T1-03 T1-04 T1-05 T1-06 T1-07 T1-09 T1-10 T1-11 – kW Vac A Hz r/min A Hz W YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 0, 2 YES – YES – – – – – – 0 YES YES YES YES YES YES – – YES 4 Stationary 2 2 YES YES YES YES YES YES YES YES – Troubleshooting Input Value Tuning Type (T1-01) 2 3 Line-to-Line Rotational for V/f Resistance Control 5 215 5.8 Auto-Tuning u Auto-Tuning Interruption and Fault Codes If tuning results are abnormal or the OFF key is pressed before completion, Auto-Tuning will be interrupted and a fault code will appear on the HOA keypad. A DIGITAL OPERATOR JVOP-180 B ALM - A.TUNE - DRV Rdy Tune Proceeding DIGITAL OPERATOR JVOP-180 - MODE - Er-03 X.XX Hz/ X.XXA STOP key <<<<<< >>> >>> FWD A – During Auto-Tuning ESC LO RE ALM DRV FWD RESET B – Auto-Tuning Aborted LO ESC Figure 5.1 Auto-Tuning Aborted Display RESET RUN u Auto-Tuning Operation Example ENTER STOP RESET RUN RE ENTER STOP The following example demonstrates Stationary Auto-Tuning for Line-to-Line Resistance. n Selecting the Type of Auto-Tuning Step 1. Turn on the power to the drive. The initial display appears. Display/Result - MODE - DRV Rdy Auto Setpoint U5-99= 0.0PSI U1-02= 0.00Hz LSEQ U1-91= 0.0PSI LREF <-MONITOR-> - MODE - PRG Auto-Tuning 2. Press or until the Auto-Tuning display appears. AUTO HELP FWD DATA - A.TUNE - PRG Rdy Tuning Mode Sel 3. Press to begin setting parameters. T1-01= 2 *2* Term Resistance ESC FWD DATA - A.TUNE - PRG Rdy Tuning Mode Sel 4. Press 5. Save the setting by pressing to display the value for T1-01. . T1-01= 2 *2* Term Resistance “2” FWD Entry Accepted - A.TUNE - PRG Rdy Tuning Mode Sel 6. The display automatically returns to the display shown in Step 3. T1-01= 2 *2* Term Resistance ESC FWD DATA n Selecting the Type of Auto-Tuning Step 1. Turn on the power to the drive. The initial display appears. Display/Result - MODE - DRV Rdy FREF (OPR) U1-01= 0.00Hz U1-02= 0.00Hz LSEQ U1-03= 0.00A LREF JOG FWD FWD/REV - MODE - PRG Auto-Tuning 2. Press or until the Auto-Tuning display appears. AUTO HELP FWD DATA 216 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 5.8 Auto-Tuning Step Display/Result - A.TUNE - PRG Rdy Tuning Mode Sel 3. Press T1-01= 2 *2* Term Resistance to begin setting parameters. ESC FWD DATA - A.TUNE - PRG Rdy Tuning Mode Sel 4. Press 5. Save the setting by pressing T1-01= 2 *2* Term Resistance “2” FWD to display the value for T1-01. . Entry Accepted - A.TUNE - PRG Rdy Tuning Mode Sel 6. The display automatically returns to the display shown in Step 3. T1-01= 2 *2* Term Resistance ESC FWD DATA n Enter Data from the Motor Nameplate After selecting the type of Auto-Tuning, enter the data required from the motor nameplate. Note: These instructions continue from Step 6 in “Selecting the Type of Auto-Tuning”. Step Display/Result - A.TUNE - PRG Rdy Mtr Rated Power 1. Press to access the motor output power parameter T1-02. T1-02= 0.75kW (0.00 ~ 650.00) “0.75kW” ESC FWD DATA - A.TUNE - PRG Rdy Mtr Rated Power 2. Press Press kW. 4. Press left - A.TUNE - PRG Rdy Mtr Rated Power F2 F1 3. T1-02= 000.75kW (0.00 ~ 650.00) “0.75kW” FWD to view the default setting. , right , , , and to enter the motor power nameplate data in to save the setting. T1-02= 000.40kW (0.00 ~ 650.00) “0.75kW” FWD Entry Accepted 5. The display automatically returns to the display in Step 1. 6. Repeat Steps 1 through 5 to set the following parameters: • T1-03, Motor Rated Voltage (Rotational Auto-Tuning for V/f Control only) • T1-04, Motor Rated Current • T1-05, Motor Base Frequency • T1-06, Number of Motor Poles • T1-07, Motor Base Frequency (Rotational Auto-Tuning for V/f Control only) • T1-09, Motor No-Load Current (Stationary Auto-Tuning 2 only) • T1-10, Motor Rated Slip (Stationary Auto-Tuning 2 only) Note: Troubleshooting - A.TUNE - PRG Rdy Mtr Rated Power T1-02= 0.40kW (0.00 ~ 650.00) “0.75kW” ESC FWD DATA - A.TUNE - PRG Rated Voltage T1-03= 200.0VAC (0.0 ~ 255.0) “200.0VAC” ESC FWD DATA 5 - A.TUNE - PRG Rated Current T1-04= X.XX A (0.35 ~ 7.00) “X.XX A” ESC FWD DATA To execute Stationary Auto-Tuning for line-to-line resistance only, set parameters T1-02 and T1-04. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 217 5.8 Auto-Tuning n Starting Auto-Tuning WARNING! Sudden Movement Hazard. The drive and motor may start unexpectedly during Auto-Tuning, which could result in death or serious injury. Ensure the area surrounding the drive motor and load are clear before proceeding with Auto-Tuning. WARNING! Electrical Shock Hazard. High voltage will be supplied to the motor when Stationary Auto-Tuning is performed even with the motor stopped, which could result in death or serious injury. Do not touch the motor until Auto-Tuning has been completed. NOTICE: Rotational Auto-Tuning will not function properly if a holding brake is engaged on the load. Failure to comply could result in improper operation of the drive. Ensure the motor can freely spin before beginning Auto-Tuning. Enter the required information from the motor nameplate. Press Note: to proceed to the Auto-Tuning start display. These instructions continue from Step 6 in “Enter Data from the Motor Nameplate”. Step Display/Result - A.TUNE - DRV Rdy Auto-Tuning 1. 2. After entering the data listed on the motor nameplate, press to confirm. Press to activate Auto-Tuning. flashes. The drive begins by injecting current into the motor for about 1 min, and then starts to rotate the motor. Note: The first digit on the display indicates which motor is undergoing Auto-Tuning. The second digit indicates the type of Auto-Tuning being performed. 0.00 Hz/ 0.00A Tuning Ready ? Press RUN key ESC FWD - A.TUNE - DRV Rdy Tune Proceeding X.XX Hz/ X.XXA <<<<<< >>> >>> FWD - MODE - 3. Auto-Tuning finishes in approximately one to two minutes. DRV End Tune Successful FWD RESET 218 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 6 Periodic Inspection & Maintenance This chapter describes the periodic inspection and maintenance of the drive to ensure that it receives the proper care to maintain overall performance. 6.1 6.2 6.3 INSPECTION........................................................................................................220 PERIODIC MAINTENANCE.................................................................................222 DRIVE REPLACEMENT.......................................................................................224 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 219 6.1 Inspection 6.1 Inspection Power electronics have limited life and may exhibit changes in characteristics or performance deterioration after years of use under normal conditions. To help avoid such problems, it is important to perform preventive maintenance and periodic inspection on the drive. Drives contain a variety of power electronics such as power transistors, semiconductors, capacitors, resistors, fans, and relays. The electronics in the drive serve a critical role in maintaining proper motor control. Follow the inspection lists provided in this chapter as a part of a regular maintenance program. Note: The drive will require more frequent inspection if it is placed in harsh environments, such as: • High ambient temperatures • Frequent starting and stopping • Fluctuations in the AC supply or load • Excessive vibrations or shock loading • Dust, metal dust, salt, sulfuric acid, chlorine atmospheres • Poor storage conditions. Perform the first equipment inspection one to two years after installation. u Recommended Periodic Inspection Table 6.1 outlines the recommended periodic inspections for Yaskawa drive installations. Although periodic inspections should generally be performed once a year; the drive may require more frequent inspection in harsh environments or with rigorous use. Operating and environmental conditions, along with experience in each application, will determine the actual inspection frequency for each installation. Periodic inspection will help to avoid premature deterioration in performance or product failure. Copy this checklist and mark the “Checked” column after each inspection. n Periodic Inspection WARNING! Electrical Shock Hazard. Do not inspect, connect, or disconnect any wiring while the power is on. Failure to comply can result in serious personal injury. Before servicing, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait for at least the time specified on the warning label; after all indicators are OFF, measure for unsafe voltages to confirm the drive is safe prior to servicing. Table 6.1 Periodic Inspection Checklist Inspection Area Inspection Points Corrective Action Main Circuit Periodic Inspection • Inspect equipment for discoloration from overheating • Replace damaged components as required. or deterioration. • The drive has few serviceable parts and may require • Inspect for damaged or deformed parts. complete drive replacement. • Inspect enclosure door seal if used. General • Use dry air to clear away foreign matter. Use a Inspect for dirt, foreign particles, or dust collection on pressure of 39.2 × 104 to 58.8 × 104 Pa components. (4 - 6 kg•cm2) (57 to 85 psi). • Replace components if cleaning is not possible. • Inspect wiring and connections for discoloration, Conductors and damage, or heat stress. Repair or replace damaged wiring. Wiring • Inspect wire insulation and shielding for wear. Inspect terminals for stripped, damaged, or loose Tighten loose screws and replace damaged screws or Terminals connections. terminals. • Inspect contactors and relays for excessive noise • Check coil voltage for overvoltage or undervoltage during operation. conditions. Relays and Contactors • Inspect coils for signs of overheating such as melted • Replace damaged removable relays, contactors, or or cracked insulation. circuit board. • Minor discoloration may be acceptable. Inspect for discoloration of heat stress on or around Braking Resistors resistors. • Check for loose connections if discoloration exists. • Inspect for leaking, discoloration, or cracks. drive has few serviceable parts and may require Electrolytic Capacitor • Check if the cap has come off, for any swelling, or if The complete drive replacement. the sides have burst open. 220 Checked YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 6.1 Inspection Inspection Area Diode, IGBT (Power Transistor) Operation Check General Circuit Boards Inspection Points Corrective Action Use dry air to clear away foreign matter. Use a Inspect for dust or other foreign material collected on the pressure of 39.2 × 104 to 58.8 × 104 Pa surface. (4 - 6 kg•cm2) (57 to 85 psi). Checked Motor Periodic Inspection Stop the motor and contact qualified maintenance Check for increased vibration or abnormal noise. personnel as required. Control Circuit Periodic Inspection • Tighten loose screws and replace damaged screws • Inspect terminals for stripped, damaged, or loose or terminals. connections. • If terminals are integral to a circuit board, then • Make sure all terminals have been properly tightened. board or drive replacement may be required. • Fix any loose connections. • If an antistatic cloth or vacuum plunger cannot be used, replace the board. Check for any odor, discoloration, and rust. Make sure • Do not use any solvents to clean the board. connections are properly fastened and that no dust or oil • Use dry air to clear away foreign matter. Use a mist has accumulated on the surface of the board. pressure of 39.2 × 104 to 58.8 × 104 Pa (4 - 6 kg•cm2) (57 to 85 psi). The drive has few serviceable parts and may require complete drive replacement. Cooling System Periodic Inspection Cooling Fan, Circulation Fan, Control Board Cooling Fan Heatsink Air Duct Replace as required. Use dry air to clear away foreign matter. Use a Inspect for dust or other foreign material collected on the pressure of 39.2 × 104 to 58.8 × 104 Pa surface. (4 - 6 kg•cm2) (57 to 85 psi). Inspect air intake and exhaust openings. They must be • Visually inspect the area. free from obstruction and properly installed. • Clear obstructions and clean air duct as required. Display Periodic Inspection • Make sure data appears on the display properly. • Contact the nearest sales office if there is any • Inspect for dust or other foreign material that may have trouble with the display or keypad. collected on surrounding components. Periodic Inspection & Maintenance HOA Keypad • Check for abnormal oscillation or unusual noise. • Check for damaged or missing fan blades. 6 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 221 6.2 Periodic Maintenance 6.2 Periodic Maintenance The drive has Maintenance Monitors that keep track of component wear. This feature provides advance maintenance warning and eliminates the need to shut down the entire system for unexpected problems. The drive allows the user to check predicted maintenance periods for the components listed below. • Cooling Fan, Circulation Fan, Control Board Cooling Fan • Electrolytic Capacitors • Inrush Prevention Circuit • IGBTs For replacement parts, contact the distributor where the drive was purchased or contact Yaskawa directly. u Replacement Parts Table 6.2 contains the estimated performance life of components that require replacement during the life of the drive. Only use Yaskawa replacement parts for the appropriate drive model and revision. Table 6.2 Estimated Performance Life Component Cooling Fan, Circulation Fan Estimated Performance Life 10 years Electrolytic Capacitors 10 years <1> <1> Electrolytic capacitors cannot be replaced on some lower capacity models. Complete drive replacement may be required for these models. NOTICE: Estimated performance life based on specific usage conditions. These conditions are provided for the purpose of replacing parts to maintain performance. Some parts may require more frequent replacement due to poor environments or rigorous use. Usage conditions for estimated performance life: Ambient temperature: Yearly average of 40 °C (IP00/Open Type enclosure) Load factor: 80% maximum Operation time: 24 hours a day n Performance Life Monitors Maintenance Monitors The drive calculates the maintenance period for components that may require replacement during the life of the drive. A percentage of the maintenance period is displayed on the HOA keypad by viewing the appropriate monitor parameter. When the maintenance period reaches 100%, there is increased risk that the drive may malfunction. Yaskawa recommends checking the maintenance period regularly to ensure maximum performance life. Refer to Recommended Periodic Inspection on page 220 for more details. Table 6.3 Performance Life Monitors Used for Component Replacement Parameter U4-03 U4-04 U4-05 U4-06 222 Component Cooling Fan Circulation Fan Control Board Cooling Fan DC Bus Capacitors Inrush (pre-charge) Relay Contents Displays the accumulated operation time of the fan, from 0 to 99999 hours. This value is automatically reset to 0 once it reaches 99999. Displays the accumulated fan operation time as a percentage of the specified maintenance period. Displays the accumulated time the capacitors are used as a percentage of the specified maintenance period. Displays the number of times the drive is powered up as a percentage of the performance life of the inrush circuit. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 6.2 Periodic Maintenance n Alarm Outputs for Maintenance Monitors An output can be set up to inform the user when a specific components has neared its expected performance life. When one of multi-function digital output terminals has been assigned the maintenance monitor function (H2-oo = 2F), the terminal will close when the cooling fan, DC bus capacitors, or DC bus pre-charge relay reach 90% of the expected performance life, or when the IGBTs have reached 50% of their expected performance life. Additionally, the HOA keypad operator will display an alarm like shown in Table 6.4 to indicate the specific components that may need maintenance. Table 6.4 Maintenance Alarms HOA Keypad Alarm Display <1> LT-1 <1> LT-2 <1> LT-3 <1> LT-4 <2> TrPC Function Corrective Action The cooling fans have reached 90% of their designated Replace the cooling fan. life time. Contact a Yaskawa representative or the The DC bus capacitors have reached 90% of their nearest Yaskawa sales office on designated life time. possible drive replacement. The pre-charge circuit has reached 90% of its designated Contact a Yaskawa representative or the nearest Yaskawa sales office on life time. possible drive replacement. The IGBTs have reached 50% of their designated life Check the load, carrier frequency, and time. output frequency. The IGBTs have reached 90% of their designated life Contact a Yaskawa representative or the nearest Yaskawa sales office on time. possible drive replacement. <1> This alarm message will be output only if the Maintenance Monitor function is assigned to one of the digital outputs (H2-oo = 2F). The alarm will also trigger a digital output that is programmed for alarm indication (H2-oo = 10). <2> This alarm message will always be output, even if the Maintenance Monitor function is not assigned to any of the digital outputs (H2-oo = 2F). The alarm will also trigger a digital output that is programmed for alarm indication (H2-oo = 10). n Related Drive Parameters Use parameters o4-03, o4-05, o4-07, and o4-09 to reset a Maintenance Monitor to zero after replacing a specific component. Refer to Parameter List on page 255 for details on parameter settings. Periodic Inspection & Maintenance NOTICE: If these parameters are not reset after the corresponding parts have been replaced, the Maintenance Monitor function will continue to count down the performance life from the value that was reached with the old part. If the Maintenance Monitor is not reset, the drive will not have the correct value of the performance life for the new component. 6 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 223 6.3 Drive Replacement 6.3 Drive Replacement u Replacing the Drive WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious personal injury. Before servicing the drive, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off. After shutting off the power, wait for at least the amount of time specified on the drive before touching any components. WARNING! Electrical Shock Hazard. Do not allow unqualified personnel to perform work on the drive. Failure to comply could result in serious injury. Installation, maintenance, inspection and servicing must be performed only by authorized personnel familiar with installation, adjustment and maintenance of AC drives. NOTICE: Observe proper electrostatic discharge procedures (ESD) when handling the drive and circuit boards. Failure to comply may result in ESD damage to the drive circuitry. The following procedure explains how to replace a drive. This section provides instructions for drive replacement only. To install option boards or other types of options, refer to the specific manuals for those options. NOTICE: When transferring a braking transistor, braking resistor, or other type of option from a damaged drive to a new replacement drive, make sure it is working properly before reconnecting it to the new drive. Replace broken options to prevent immediate breakdown of the replacement drive. 1. Remove the terminal cover. Figure 6.1 Remove the Terminal Cover 2. Note: Loosen the screws holding the terminal board in place. Remove the screw securing the bottom cover and remove the bottom cover from the drive. IP00/Open Type enclosure drives do not have a bottom cover or conduit. Figure 6.2 Unscrew the Terminal Board and Remove the Bottom Cover 3. 224 Slide the terminal board as illustrated by the arrows to remove it from the drive along with the bottom cover. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 6.3 Drive Replacement Figure 6.3 Remove the Terminal Board Figure 6.4 Disconnected Removable Terminal Board 4. 5. Disconnect all option cards and options, making sure they are intact before reusing. Replace the drive and wire the main circuit. n Installing the Drive After wiring the main circuit, connect the terminal block to the drive as shown in Figure 6.5. Use the installation screw to fasten the terminal block into place. Figure 6.5 Install the Terminal Board 2. 3. 4. Reconnect options for the new drive the same way the options were connected in the old drive. Connect option boards to the same option ports in the new drive that were used in the old drive. Replace the terminal cover. After powering on the drive, all parameter settings are transferred from the terminal board to the drive memory. If an oPE04 error occurs, load the parameter settings saved on the terminal board to the new drive by setting parameter A1-03 to 5550. Reset the Maintenance Monitor function timers by setting parameters o4-01 through o4-12 to 0, and parameter o4-13 to 1. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 225 Periodic Inspection & Maintenance 1. 6 6.3 Drive Replacement This Page Intentionally Blank 226 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 7 Peripheral Devices & Options This chapter explains option installation procedures for the drive. 7.1 OPTION CARD INSTALLATION..........................................................................228 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 227 7.1 Option Card Installation 7.1 Option Card Installation This section provides instructions on installing option cards. u Prior to Installing the Option Prior to installing the option, wire the drive, make necessary connections to the drive terminals, and verify that the drive functions normally without the option installed. Table 7.1 below lists the number of options that can be connected to the drive and the drive ports for connecting those options. Table 7.1 Option Installation Option SI-P3, SI-EP3, SI-N3, SI-EN3, SI-EM3, SI-B3, SI-W3, SI-J3 AO-A3, DO-A3 Port/Connector Number of Options Possible CN5-A 1 CN5-A, B, C 1 Figure 7.1 shows an exploded view of the drive with the option and related components for reference. I J K A M L B H C G F NS TX MS RX E D A – Drive front cover B – HOA keypad C – LED label (for communication options) D – Drive terminal cover E – Removable tabs for wire routing F – Included screws G – Ground wire H – Drive grounding terminal (FE) I – Connector CN5-C J – Connector CN5-B K – Connector CN5-A L – Insertion point for CN5 connector M – Option Figure 7.1 Drive Components with Option 228 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 7.1 Option Card Installation u Communication Option Installation Example Remove the front covers of the drive before installing the option. Communication options can inserted only into the CN5-A connector located on the drive control board. Preparing the Drive 1. Shut off power to the drive, wait the appropriate amount of time for voltage to dissipate, then remove the HOA keypad (B) and front covers (A, D). Front cover removal varies by model. DANGER! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply will result in death or serious injury. Before installing the option, disconnect all power to the drive. The internal capacitor remains charged even after the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait at least five minutes after all indicators are off and measure the DC bus voltage level to confirm safe level. NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling the option, drive, and circuit boards. Failure to comply may result in ESD damage to circuitry. A B D Figure 7.2 Remove the Front Covers and HOA Keypad 2. With the front covers and HOA keypad removed, apply the LED label (C) in the appropriate position on the drive top front cover (A). A NS TX MS RX C Connecting Option and Ground Wire 1. Insert the option (M) into the CN5-A connector (K) located on the drive and fasten it using one of the included screws (F). Peripheral Devices & Options Figure 7.3 Apply the LED Label 7 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 229 7.1 Option Card Installation K M L F NS TX MS RX Figure 7.4 Insert the Option 2. Connect the ground wire (G) to the ground terminal (H) using one of the remaining provided screws (F). Connect the other end of the ground wire (G) to the remaining ground terminal and installation hole on the option (M) using the last remaining provided screw (F) and tighten both screws to 0.5 ~ 0.6 N m or (4.4 ~ 5.3 in lbs). M H NS TX G MS RX F Figure 7.5 Connect the Ground Wire Note: There are two screw holes on the drive for use as ground terminals. When connecting three options, two ground wires will need to share the same drive ground terminal. Wiring the Option 1. Route the option wiring. Depending on the drive model, some drives may require routing the wiring through the side of the front cover to the outside to provide adequate space for the wiring. In these cases, using diagonal cutting pliers, cut out the perforated openings on the left side of the drive front cover. Sharp edges along the cut out should be smoothed down with a file or sand paper to prevent any damage to the wires. 2. Note: When installing option cards to models 2A0004 to 2A0040, 4A0002 to 4A0023, and 5A0003 to 5A0011, it may be necessary to route the cables connected to the option through the top cover to the outside. Models 2A0056 to 2A0415, 4A0031 to 4A1200, and 5A0017 to 5A0242 have enough space to keep all wiring inside the unit. Connect the communication cables to the option terminal block (TB1). Separate the communications cables from the main circuit cables and other wiring and power cables. Use properly grounded shielded cables for the communication cables to prevent problems caused by electrical interference. Replacing the Drive Covers and HOA Keypad 1. Replace and secure the front covers of the drive (A, D) and replace the HOA keypad (B). 230 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 7.1 Option Card Installation A B NS TX MS RX D Figure 7.6 Replace the Front Covers and HOA Keypad Take proper precautions when wiring the option so that the front covers will easily fit back onto the drive. Make sure no cables are pinched between the front covers and the drive when replacing the covers. Peripheral Devices & Options Note: 7 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 231 7.1 Option Card Installation This Page Intentionally Blank 232 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Appendix: A Specifications A.1 A.2 A.3 A.4 POWER RATINGS...............................................................................................234 DRIVE SPECIFICATIONS....................................................................................243 DRIVE WATT LOSS DATA..................................................................................245 DRIVE DERATING DATA....................................................................................247 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 233 A.1 Power Ratings A.1 Power Ratings u Three-Phase 200 V Class Drive Models 2A0004 to 2A0030 Table A.1 Power Ratings (Three-Phase 200 V Class) Item Drive Model Maximum Applicable Motor Capacity (HP) <1> Input ND Rating ND Rating Input Current (A) <2> Rated Voltage Rated Frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation Input Power (kVA) ND Rating Rated Output Capacity ND Rating <5> (kVA) <4> Rated Output Current (A) Output Specification 2A0004 2A0006 2A0008 2A0010 2A0012 2A0018 2A0021 2A0030 ND Rating <5> 0.75 1 2 3 3 5 7.5 10 3.9 7.3 8.8 10.8 13.9 18.5 24 37 Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc <3> -15 to 10% ±5% 5.8 7.8 9.5 14 18 2.2 3.1 4.1 1.3 2.3 3 3.7 4.6 6.7 8 11.4 3.5 6 8 9.6 12 17.5 21 30 Overload Tolerance ND Rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) Carrier Frequency User-adjustable between 1 and 15 kHz <5> Three-phase 200 to 240 V (proportional to input voltage) 400 Hz (user-set) Maximum Output Voltage (V) Maximum Output Frequency (Hz) <1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current. <2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance. <3> DC is not available for UL/CE standards. <4> Rated motor capacity is calculated with a rated output voltage of 220 V. <5> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings raise the carrier frequency and require current derating. 234 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide A.1 Power Ratings u Three-Phase 200 V Class Drive Models 2A0040 to 2A0211 Table A.2 Power Ratings Continued (Three-Phase 200 V Class) Item Drive Model Maximum Applicable Motor Capacity (HP) <1> Input ND Rating ND Rating Input Current (A) <2> Rated Voltage Rated Frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation Input Power (kVA) ND Rating Rated Output Capacity ND Rating <5> (kVA) <4> Rated Output Current (A) ND Rating Overload Tolerance Output Carrier Frequency Maximum Output Voltage (V) Maximum Output Frequency (Hz) <5> Specification 2A0081 2A0110 2A0040 2A0056 2A0069 2A0138 2A0169 2A0211 15 20 25 30 40 50 60 75 52 68 80 96 111 136 164 200 Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc <3> 27 36 44 -15 to 10% ±5% 52 51 15.2 21 26 31 42 53 64 80 40 56 69 81 110 138 169 211 62 75 91 ND Rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) User-adjustable between 1 and User-adjustable between 1 and 15 kHz <5> 10 kHz <5> Three-phase 200 to 240 V (proportional to input voltage) 400 Hz (user-set) Specifications <1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current. <2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance. <3> DC is not available for UL/CE standards. <4> Rated motor capacity is calculated with a rated output voltage of 220 V. <5> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings raise the carrier frequency and require current derating. A YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 235 A.1 Power Ratings u Three-Phase 200 V Class Drive Models 2A0250 to 2A0415 Table A.3 Power Ratings Continued (Three-Phase 200 V Class) Item Drive Models <1> 2A0415 100 125 150 175 ND Rating Input Current (A) <2> Rated Voltage Rated Frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation Input Power (kVA) ND Rating 271 324 394 471 Rated Output Capacity (kVA) <4> Rated Output Current (A) Output Specification 2A0312 2A0360 ND Rating Maximum Applicable Motor Capacity (HP) Input 2A0250 Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc <3> -15 to 10% ±5% 124 148 180 215 ND Rating <5> 95 119 137 158 ND Rating <5> 250 312 360 415 Overload Tolerance ND Rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) Carrier Frequency User-adjustable between 1 and 10 kHz <5> Three-phase 200 to 240 V (proportional to input voltage) 400 Hz (user-set) Maximum Output Voltage (V) Maximum Output Frequency (Hz) <1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current. <2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance. <3> DC is not available for UL/CE standards. <4> Rated motor capacity is calculated with a rated output voltage of 220 V. <5> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings raise the carrier frequency and require current derating. 236 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide A.1 Power Ratings u Three-Phase 400 V Class Drive Models 4A0002 to 4A0031 Table A.4 Power Ratings (Three-Phase 400 V Class) Item Drive Models Maximum Applicable Motor Capacity (HP) <1> Input Output Specification 4A0002 4A0004 4A0005 4A0007 4A0009 4A0011 4A0018 4A0023 4A0031 ND Rating 0.75 2 3 3 5 7.5 10 15 20 Input Current (A) <2> ND Rating Rated Voltage Rated Frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation Input Power (kVA) ND Rating 2.1 4.3 5.9 8.1 9.4 14 20 24 38 Three-phase: 380 to 480 Vac 50/60 Hz/510 to 680 Vdc <3> 2.3 4.3 6.1 8.1 -15 to 10% ±5% 10.0 14.5 19.4 28.4 37.5 Rated Output Capacity (kVA) <4> ND Rating 1.6 3.1 4.1 5.3 6.7 8.5 13.3 17.5 24 Rated Output Current (A) ND Rating 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23 31 <5> <5> Overload Tolerance ND Rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) Carrier Frequency User-adjustable between 1 and 15 kHz <5> Three-phase: 380 to 480 V (proportional to input voltage) 400 Hz (user-adjustable) Maximum Output Voltage (V) Maximum Output Frequency (Hz) Specifications <1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current. <2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance. <3> DC is not available for UL/CE standards. <4> Rated motor capacity is calculated with a rated output voltage of 440 V. <5> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings raise the carrier frequency and require current derating. A YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 237 A.1 Power Ratings u Three-Phase 400 V Class Drive Models 4A0038 to 4A0165 Table A.5 Power Ratings Continued (Three-Phase 400 V Class) Item Drive Models Maximum Applicable Motor Capacity (HP) <1> Input Output Specification 4A0038 4A0044 4A0058 4A0072 4A0088 ND Rating ND Rating Input Current (A) <2> Rated Voltage Rated Frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation Input Power (kVA) ND Rating Rated Output Capacity ND Rating <5> (kVA) <4> Rated Output Current ND Rating <5> (A) Overload Tolerance Carrier Frequency Maximum Output Voltage (V) Maximum Output Frequency (Hz) 4A0103 4A0139 4A0165 25 30 40 50 60 75 100 125 44 52 58 71 86 105 142 170 Three-phase: 380 to 480 Vac 50/60 Hz/510 to 680 Vdc <3> -15 to 10% ±5% 64.9 78.6 46.6 54.9 53.0 29 34 44 55 38 44 58 72 96.0 130 156 67 78 106 126 88 103 139 165 ND Rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) User-adjustable between 1 and User-adjustable between 1 and 15 kHz <5> 10 kHz <5> Three-phase: 380 to 480 V (proportional to input voltage) 400 Hz (user-adjustable) <1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current. <2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance. <3> DC is not available for UL/CE standards. <4> Rated motor capacity is calculated with a rated output voltage of 440 V. <5> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings raise the carrier frequency and require current derating. 238 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide A.1 Power Ratings u Three-Phase 400 V Class Drive Models 4A0208 to 4A0675 Table A.6 Power Ratings Continued (Three-Phase 400 V Class) Item Drive Models Maximum Applicable Motor Capacity (HP) <1> Input Current (A) Input <2> Output 4A0250 4A0296 ND Rating 150 200 250 300 ND Rating 207 248 300 346 Rated Voltage Rated Frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation Input Power (kVA) ND Rating Rated Output Capacity ND Rating <5> (kVA) <4> Rated Output Current (A) Specification 4A0362 4A0414 4A0208 ND Rating Overload Tolerance Carrier Frequency Maximum Output Voltage (V) Maximum Output Frequency (Hz) <5> 4A0515 4A0675 350 400-450 500-550 410 465 657 Three-phase: 380 to 480 Vac 50/60 Hz/510 to 680 Vdc <3> 189 227 274 -15 to 10% ±5% 316 159 191 226 276 316 392 514 208 250 296 362 414 515 675 375 425 601 ND Rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) User-adjustable between 1 and 5 kHz <5> Three-phase: 380 to 480 V (proportional to input voltage) 400 Hz (user-adjustable) User-adjustable between 1 and 10 kHz <5> Specifications <1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current. <2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance. <3> DC is not available for UL/CE standards. <4> Rated motor capacity is calculated with a rated output voltage of 440 V. <5> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings raise the carrier frequency and require current derating. A YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 239 A.1 Power Ratings u Three-Phase 600 V Class Drive Models 5A0003 to 5A0032 Table A.7 Power Ratings (Three-Phase 600 V Class) Item Drive Models 5A0003 Maximum Applicable Motor ND Rating 2 Capacity (HP) <1> Input Current ND Rating 3.6 (A) <2> Rated Voltage Rated Frequency Input Allowable Voltage Fluctuation Allowable Frequency Fluctuation Input Power ND Rating 4.1 (kVA) Rated Output ND Rating 2.7 Capacity (kVA) <4> <3> Rated Output Current (A) Output ND Rating <4> Overload Tolerance Carrier Frequency Maximum Output Voltage (V) Maximum Output Frequency (Hz) 2.7 Specification 5A0009 5A0011 5A0017 5A0004 5A0006 3 5 7.5 10 5.1 8.3 12 16 5A0022 5A0027 5A0032 15 20 25 30 23 31 38 45 Three-phase 500 to 600 Vac 50/60 Hz -10 (-15) to +10% ±5% 5.8 9.5 14 18 26 35 43 51 3.9 6.1 9 11 17 22 27 32 3.9 6.1 9 11 17 22 27 32 ND Rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) User-adjustable between 1 and 15 kHz <4> User-adjustable between 1 and 10 kHz <4> Three-phase 500 to 600 V (proportional to input voltage) 400 Hz (user-set) <1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current. <2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance. <3> Rated motor capacity is calculated with a rated output voltage of 575 V. <4> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings raise the carrier frequency and require current derating. 240 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide A.1 Power Ratings u Three-Phase 600 V Class Drive Models 5A0041 to 5A0099 Table A.8 Power Ratings Continued (Three-Phase 600 V Class) Item Drive Models 5A0041 5A0052 Specification 5A0062 5A0077 5A0099 ND Rating 40 50 60 75 100 ND Rating Input Current (A) <2> Rated Voltage Rated Frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation Input Power (kVA) ND Rating 44 54 66 80 108 Maximum Applicable Motor Capacity (HP) Input Rated Output Capacity (kVA) <1> <3> Rated Output Current (A) Three-phase 500 to 600 Vac 50/60 Hz 50 62 -10 (-15) to +10% ±5% 75 91 123 ND Rating <4> 41 52 62 77 99 ND Rating <4> 41 52 62 77 99 Overload Tolerance Output Carrier Frequency Maximum Output Voltage (V) Maximum Output Frequency (Hz) ND Rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) Useradjustable <4> User-adjustable between 1 and 10 kHz between 1 and 8 kHz <4> Three-phase 500 to 600 V (proportional to input voltage) 400 Hz (user-set) Specifications <1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current. <2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance. <3> Rated motor capacity is calculated with a rated output voltage of 575 V. <4> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings raise the carrier frequency and require current derating. A YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 241 A.1 Power Ratings u Three-Phase 600 V Class Drive Models 5A0125 to 5A0242 Table A.9 Power Ratings Continued (Three-Phase 600 V Class) Item Drive Models <1> 5A0242 125 150 200 250 ND Rating Input Current (A) <2> Rated Voltage Rated Frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation Input Power (kVA) ND Rating 129 158 228 263 Rated Output Capacity (kVA) <3> Rated Output Current (A) Output Specification 5A0145 5A0192 ND Rating Maximum Applicable Motor Capacity (HP) Input 5A0125 Three-phase 500 to 600 Vac 50/60 Hz 147 -10 (-15) to +10% ±5% 181 261 301 ND Rating <4> 124 144 191 241 ND Rating <4> 125 145 192 242 Overload Tolerance ND Rating: 120% of rated output current for 60 s (Derating may be required for applications that start and stop frequently) Carrier Frequency User-adjustable between 1 and 3 kHz <4> Three-phase 500 to 600 V (proportional to input voltage) 400 Hz (user-set) Maximum Output Voltage (V) Maximum Output Frequency (Hz) <1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current. <2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance. <3> Rated motor capacity is calculated with a rated output voltage of 575 V. <4> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings raise the carrier frequency and require current derating. 242 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide A.2 Drive Specifications A.2 Drive Specifications Note: 1. Perform rotational Auto-Tuning to obtain the performance specifications given below. 2. For optimum performance life of the drive, install the drive in an environment that meets the required specifications. Item Specification The following control methods can be set using drive parameters: • V/f Control (V/f) • Open Loop Vector Control (OLV) Control Method Frequency Control Range Frequency Accuracy (Temperature Fluctuation) 0.01 to 400 Hz Digital input: within ±0.01% of the max output frequency (-10 to +40 °C) Analog input: within ±0.1% of the max output frequency (25 °C ±10 °C) Digital inputs: 0.01 Hz Frequency Setting Resolution Analog inputs: 1/2048 of the maximum output frequency setting (11 bit plus sign) Resolution of analog inputs A1 and A3 is 10 bit + sign in current mode Output Frequency Resolution 0.001 Hz Main speed frequency reference: DC -10 to +10 V (20 kΩ), DC 0 to +10 V (20 kΩ), Frequency Setting Signal 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω) Main speed reference: Pulse train input (max. 32 kHz) Speed Control Range Control Characteristics V/f: 150% at 3 Hz OLV: 200% at 0.3 Hz <1> Speed Control Accuracy Speed Response <1> <1> OLV: ±0.2% (25 °C ±10 °C) OLV Torque Limit Parameters setting allow separate limits in four quadrants (available in OLV) Accel/Decel Time 0.0 to 6000.0 s (2 selectable combinations of independent acceleration and deceleration settings) Braking Torque Braking Transistor V/f Characteristics Main Control Functions Motor Protection Momentary Overcurrent Protection Protection Functions V/f: 1:40 OLV: 1:200 <1> Overload Protection Overvoltage Protection Undervoltage Protection Approx. 20% (approx. 125% when using braking resistor) <2> • Short-time decel torque <3> : over 100% for 0.4/ 0.75 kW motors, over 50% for 1.5 kW motors, and over 20% for 2.2 kW and above motors <4> (overexcitation braking/High Slip Braking: approx. 40%) • Continuous regenerative torque: approx. 20% <4> (approx. 125% with dynamic braking resistor option <2> : 10% ED, 10s) Models 2A0004 to 2A0138, 4A0002 to 4A0072, and 5A0003 to 5A0052 have a built-in braking transistor. User-selected programs and V/f preset patterns possible Momentary Power Loss Ride-Thru, Speed Search, Overtorque/Undertorque Detection, Torque Limit, 17 Step Speed (max), Accel/decel Switch, S-curve Accel/decel, 3-wire Sequence, Auto-tuning (rotational, stationary tuning), Dwell, Cooling Fan on/off Switch, Slip Compensation, Frequency Jump, Upper/lower Limits for Frequency Reference, DC Injection Braking at Start and Stop, Overexcitation Braking, High Slip Braking, PID Control (with sleep function), Energy Saving Control, MEMOBUS/ Modbus Comm. (RS-422/RS-485 max, 115.2 kbps), Fault Restart, Application Presets, DriveWorksEZ (customized function), Removable Terminal Block with Parameter Backup Function, Online Tuning, KEB, Overexcitation Deceleration, Overvoltage Suppression, Dynamic Noise Control. Electronic thermal overload relay Drive stops when output current exceeds 170% of rated output current Drive stops when rated output current is 120% for 60 s <5> 200 V class: Stops when DC bus voltage exceeds approx. 410 V 400 V class: Stops when DC bus voltage exceeds approx. 820 V 600 V class: Stops when DC bus voltage exceeds approx. 1040 V 200 V class: Stops when DC bus voltage falls below approx. 190 V 400 V class: Stops when DC bus voltage falls below approx. 380 V 600 V class: Stops when DC bus voltage falls below approx. 475 V Specifications Starting Torque A YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 243 A.2 Drive Specifications Item Specification Immediately stop after 15 ms or longer power loss <6> . Continuous operation during power loss than 2 s (standard) <7> Heatsink Overheat Protection Thermistor Braking Resistor Overheat Overheat input signal for braking resistor (Optional ERF-type, 3% ED) Protection Stall Prevention Stall Prevention is available during acceleration, deceleration, and during run. Momentary Power Loss Ride-Thru Protection Functions Ground Protection DC Bus Charge LED Area of Use Ambient Temperature Humidity Environment Storage Temperature Altitude Vibration/Shock Safety Standard Protection Design Electronic circuit protection <8> Remains lit until DC bus voltage falls below 50 V Indoors -10 to +40 °C (IP20/NEMA Type 1 enclosure), -10 to +50 °C (IP00/Open Type enclosure) 95 RH% or less (no condensation) -20 to +60 °C (short-term temperature during transportation) Up to 1000 meters without derating, up to 3000 m with output current and voltage derating. 10 to 20 Hz: 9.8 m/s2 20 to 55 Hz: 5.9 m/s2 (2A0004 to 2A0211, 4A0002 to 4A0165, and 5A0003 to 5A0099) 2.0 m/s2 (2A0250 to 2A0415, 4A0208 to 4A0675, and 5A0125 to 5A0242) UL 508C (Power Conversion), UL/cUL listed, CSA 22.2 No. 14-05 (Industrial Control Equipment), CE marked, RoHS compliant, EN 61800-5-1 (LVD), EN 61800-3 (EMC), IEC60529 IP00/Open Type enclosure, IP20/NEMA Type 1 enclosure <9> <1> The accuracy of these values depends on motor characteristics, ambient conditions, and drive settings. Specifications may vary with different motors and with changing motor temperature. Contact Yaskawa for consultation. <2> Disable Stall Prevention during deceleration (L3-04 = 0) when using a regenerative converter, a regenerative unit, a braking resistor or the Braking Resistor Unit. The default setting for the Stall Prevention function will interfere with the braking resistor. <3> Instantaneous average deceleration torque refers to the torque required to decelerate the motor (uncoupled from the load) from the rated motor speed down to zero in the shortest time. <4> Actual specifications may vary depending on motor characteristics. <5> Overload protection may be triggered when operating with 150% of the rated output current if the output frequency is less than 6 Hz. <6> May be shorter due to load conditions and motor speed. <7> A separate Momentary Power Loss Ride-Thru Unit is required for models 2A0004 to 2A0056 and 4A0002 to 4A0031 if the application needs to continue running for up to 2 seconds during a momentary power loss. <8> Ground protection cannot be provided when the impedance of the ground fault path is too low, or when the drive is powered up while a ground fault is present at the output. <9> Removing the top protective cover or bottom conduit bracket from an IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection while maintaining IP20 conformity. This is applicable to models 2A0004 to 2A0211, 4A0002 to 4A0165, and 5A0003 to 5A0242. 244 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide A.3 Drive Watt Loss Data A.3 Drive Watt Loss Data Table A.10 Watt Loss 200 V Class Three-Phase Models Drive Model Normal Duty Rated Amps (A) <1> Heatsink Loss (W) Interior Unit Loss (W) Total Loss (W) 2A0004 3.5 18.4 47 66 2A0006 6.0 31 51 82 2A0008 8.0 43 52 95 2A0010 9.6 57 58 115 2A0012 12.0 77 64 141 2A0018 17.5 101 67 168 2A0021 21 138 83 222 2A0030 30 262 117 379 2A0040 40 293 145 437 2A0056 56 371 175 546 2A0069 69 491 205 696 2A0081 81 527 257 785 2A0110 110 719 286 1005 2A0138 138 842 312 1154 2A0169 169 1014 380 1394 2A0211 211 1218 473 1691 2A0250 250 1764 594 2358 2A0312 312 2020 665 2686 2A0360 360 2698 894 3591 2A0415 415 2672 954 3626 <1> Value assumes the carrier frequency is 2 kHz (C6-02 = 1, 7, 8, 9, or A). Table A.11 Watt Loss 400 V Class Three-Phase Models Normal Duty Rated Amps (A) <1> Heatsink Loss (W) Interior Unit Loss (W) Total Loss (W) 4A0002 2.1 20 48 68 4A0004 4.1 32 49 81 4A0005 5.4 45 53 97 4A0007 6.9 62 59 121 4A0009 8.8 66 60 126 4A0011 11.1 89 73 162 4A0018 17.5 177 108 285 4A0023 23 216 138 354 4A0031 31 295 161 455 4A0038 38 340 182 521 4A0044 44 390 209 599 4A0058 58 471 215 686 4A0072 72 605 265 870 4A0088 88 684 308 993 4A0103 103 848 357 1205 4A0139 139 1215 534 1749 4A0165 165 1557 668 2224 4A0208 208 1800 607 2408 4A0250 250 2379 803 3182 4A0296 296 2448 905 3353 4A0362 362 3168 1130 4298 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Specifications Drive Model A 245 A.3 Drive Watt Loss Data Drive Model Normal Duty Rated Amps (A) <1> Heatsink Loss (W) Interior Unit Loss (W) Total Loss (W) 4A0414 414 3443 1295 4738 4A0515 515 4850 1668 6518 4A0675 675 4861 2037 6898 <1> Value assumes the carrier frequency is 2 kHz (C6-02 = 1, 7, 8, 9, or A). Table A.12 Watt Loss Three-Phase 600 V Class Three-Phase Models Drive Model Normal Duty Rated Amps (A) <1> Heatsink Loss (W) Interior Unit Loss (W) Total Loss (W) 5A0003 2.7 21.5 23.3 44.8 5A0004 3.9 27.5 33.6 61.1 5A0006 6.1 28.1 43.7 71.8 5A0009 9.0 43.4 68.9 112.3 5A0011 11 56.1 88.0 144.0 5A0017 17 96.6 146.7 243.2 5A0022 22 99.4 178.3 277.7 5A0027 27 132.1 227.2 359.3 5A0032 32 141.6 279.9 421.5 5A0041 41 330.8 136.2 467.0 5A0052 52 427.8 166.2 594.0 5A0062 62 791.2 279.0 1070.2 5A0077 77 959.1 329.4 1288.6 5A0099 99 1253.2 411.7 1664.9 5A0125 125 1641 537 2178 5A0145 145 1860 603 2463 5A0192 192 2420 769 3189 5A0242 242 3100 1131 4231 <1> Value assumes the carrier frequency is 2 kHz (C6-02 = 1, 7, 8, 9, or A). 246 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide A.4 Drive Derating Data A.4 Drive Derating Data The drive can be operated at above the rated temperature, altitude, and default carrier frequency by derating the drive capacity. u Single-Phase Derating iQpump1000 drives are compatible for use with both three-phase and single-phase input power supplies. The drive output to the motor is always three-phase, regardless of number of input phases. Output capacity to the motor is derated when using single-phase input power and the drive firmware includes protection for single-phase input applications. This protection is enabled by default. Disabling this protection for single-phase input applications can void warranty and result in premature failure. Selection of larger models always results in greater output capacity to the motor when supplying the drive with three-phase input power. However, the selection of larger models does not always yield greater output capacity when using the drive with single-phase input power. Several factors affect the amount of derated drive output capacity when single-phase input power is supplied to the drive, such as: • single-phase input voltage level • motor voltage rating • amount of input impedance. The tables in this section assist in model selection by considering factors that affect the amount of derating in single-phase input power applications. There are two sizing methods based on the maximum load applied to the motor. Sizing Method A provides continuous full power and Sizing Method B may allow the connection of a larger motor compared to Method A, but the load is limited to 86% motor power, which is often (but not always) adequate for fan and pump loads. n Single-Phase Input Sizing Method A (Continuous Full Power) Use single-phase input Sizing Method A for applications requiring more than 86% motor power. The Output Capacity Motor FLA listed in the tables allows for a 120% overload for 60 seconds. Contact Yaskawa if assistance is needed in selecting drive models for heavy duty/single-phase applications with higher overload requirements. Note: Adding more impedance than is specified will degrade performance. Without Additional Impedance Drive Model 2A0004 2A0006 2A0008 2A0010 2A0012 2A0018 2A0021 2A0030 2A0040 2A0056 2A0069 2A0081 Output Capacity Motor Power (HP) 0.33 0.5 0.75 0.75 1 2 2 2 3 5 5 10 Single Phase Input Load Motor FLA Power (kVA) Current (A) 1.52 2.2 3.2 3.2 4.2 6.8 6.8 6.8 9.6 15.2 15.2 28 0.99 1.3 1.7 1.8 2.3 4.3 4.3 4.5 6.2 9.9 10 18 4.3 5.7 7.7 7.7 10 19 19 20 27 43 45 79 With Additional Impedance (use either DC type or AC type) Yaskawa Reactor Part Single Phase Output Capacity Number Input Load Motor Motor Power DC Type AC Type Current (A) Power FLA (kVA) (HP) URX000043 URX000303 0.5 2.2 0.94 4.1 URX000043 URX000303 0.75 3.2 1.3 5.7 05P00620-0113 URX000307 1 4.2 1.6 7.2 05P00620-0113 URX000311 1 4.2 1.8 7.8 URX000048 URX000316 2 7.5 2.9 13 05P00620-0120 URX000319 3 9.6 4.3 19 05P00620-0120 URX000323 3 9.6 4.4 19 05P00620-0120 URX000323 3 9.6 4.4 19 05P00620-0124 URX000323 5 15.2 6.7 30 URX000059 URX000326 7.5 22 9.6 42 URX000063 URX000332 10 28 13 56 URX000072 URX000338 15 42 19 84 Specifications Table A.13 Sizing Method A, 240 V Single-Phase Input (-5% to +10%), 230 V Three-Phase Motor A YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 247 A.4 Drive Derating Data With Additional Impedance (use either DC type or AC type) Without Additional Impedance Drive Model 2A0110 2A0138 2A0169 2A0211 2A0250 2A0312 2A0360 2A0415 Output Capacity Motor Power (HP) 10 15 20 20 25 30 40 50 Single Phase Input Load Motor FLA Power (kVA) Current (A) 28 42 54 54 68 80 104 130 14 20 26 26 32 39 51 63 60 87 114 116 143 170 224 275 Yaskawa Reactor Part Number Output Capacity Motor Power (HP) 10 15 20 20 DC Link Choke Do Not Use AC Built-in Reactor 25 30 40 50 DC Type AC Type Single Phase Input Load Motor FLA Power (kVA) Current (A) 28 42 54 54 68 80 104 130 14 20 26 26 32 39 51 63 60 87 114 116 143 170 224 275 Table A.14 Sizing Method A, 240 V Single-Phase Input (-5% to +10%), 208 V Three-Phase Motor Without Additional Impedance Drive Model 2A0004 2A0006 2A0008 2A0010 2A0012 2A0018 2A0021 2A0030 2A0040 2A0056 2A0069 2A0081 2A0110 2A0138 2A0169 2A0211 2A0250 2A0312 2A0360 2A0415 248 Output Capacity Motor Power (HP) 0.33 0.5 0.75 0.75 1 2 2 2 3 5 5 10 10 15 20 20 25 30 40 50 Single Phase Input Load Motor FLA Power (kVA) Current (A) 1.7 2.4 3.5 3.5 4.6 7.5 7.5 7.5 10.6 17 17 31 31 46 59 59 75 88 114 143 0.99 1.3 1.7 1.8 2.3 4.3 4.3 4.5 6.2 9.9 10 18 14 20 26 26 32 39 51 63 4.3 5.7 7.7 7.7 10 19 19 20 27 43 45 79 60 87 114 116 143 170 224 275 With Additional Impedance (use either DC type or AC type) Yaskawa Reactor Part Single Phase Output Capacity Number Input Load Motor Motor Power DC Type AC Type Current (A) Power FLA (kVA) (HP) URX000043 URX000303 0.5 2.4 0.94 4.1 URX000043 URX000303 0.75 3.5 1.3 5.7 05P00620-0113 URX000307 1 4.6 1.6 7.2 05P00620-0113 URX000311 1 4.6 1.8 7.8 05P00620-0115 URX000315 2 7.5 2.9 13 05P00620-0120 URX000319 3 10.6 4.3 19 05P00620-0120 URX000323 3 10.6 4.4 19 05P00620-0120 URX000323 3 10.6 4.4 19 05P00620-0124 URX000323 5 17 6.7 30 URX000059 URX000326 7.5 24 9.6 42 URX000063 URX000332 10 31 13 56 URX000072 URX000339 15 46 19 84 URX000340 15 46 17 76 URX000343 15 46 18 77 URX000342 20 59 23 102 URX000344 25 75 29 129 DC Link Choke Built-in URX000347 30 88 35 156 URX000350 40 114 47 204 URX000353 50 143 57 252 URX000356 60 169 69 301 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide A.4 Drive Derating Data Table A.15 Sizing Method A, 480 V Single-Phase Input (-5% to +10%), 460 V Three-Phase Motor Without Additional Impedance Drive Model Output Capacity Single Phase Input Load Motor FLA Power (kVA) Current (A) 4A0002 4A0004 4A0005 4A0007 4A0009 4A0011 4A0018 4A0023 4A0031 Motor Power (HP) 0.33 0.75 1 1 2 2 2 3 5 0.76 1.6 2.1 2.1 3.4 3.4 3.4 4.8 7.6 1.1 1.9 2.3 2.5 4.6 4.6 4.4 6.3 10 2.4 4.2 5.1 5.6 10 10 9.7 14 22 4A0038 4A0044 4A0058 4A0072 4A0088 4A0103 4A0139 4A0165 4A0208 4A0250 4A0296 4A0362 4A0414 4A0515 4A0675 7.5 7.5 10 15 15 15 30 30 50 60 60 75 100 100 125 11 11 14 21 21 21 40 40 65 77 77 96 124 124 156 14 14 14 20 20 20 38 39 62 74 75 93 122 125 157 31 31 30 43 44 45 84 85 136 162 165 205 267 275 345 With Additional Impedance (use either DC type or AC type) Yaskawa Reactor Part Single Phase Output Capacity Number Input Load Motor Motor Power DC Type AC Type Current (A) Power FLA (kVA) (HP) URX000041 URX000295 0.5 1.1 0.98 2.1 URX000041 URX000299 1 2.1 1.7 3.8 05P00620-0110 URX000303 1.5 3 2.5 5.5 05P00652-0213 URX000308 2 3.4 3 6.7 URX000048 URX000312 3 4.8 4.3 9.5 URX000053 URX000316 3 4.8 4.7 10 URX000052 URX000316 3 4.8 4.6 10 URX000052 URX000316 5 7.6 7 15 URX000055 URX000324 7.5 11 9.9 22 05P00620-0123 URX000061 URX000327 URX000327 URX000332 Do Not Use AC Reactor DC Link Choke Built-in URX000335 URX000341 URX000341 URX000347 URX000347 URX000350 URX000353 URX000356 URX000353 Do Not Use 10 10 15 15 15 20 30 30 50 60 75 100 125 100 125 14 14 21 21 21 27 40 40 65 77 96 124 156 124 156 14 13 19 20 20 25 36 37 59 70 87 115 143 116 157 31 28 41 43 44 54 80 81 130 154 192 251 314 255 345 Without Additional Impedance Drive Model 4A0002 4A0004 4A0005 4A0007 4A0009 4A0011 4A0018 4A0023 4A0031 4A0038 4A0044 Output Capacity Motor Power (HP) 0.33 0.75 1 1 2 2 2 3 5 7.5 7.5 Single Phase Input Load Motor FLA Power (kVA) Current (A) 0.88 1.8 2.4 2.4 3.9 3.9 3.9 5.5 8.7 12.7 12.7 1.1 1.9 2.3 2.5 4.6 4.6 4.4 6.3 10 14 14 2.4 4.2 5.1 5.6 10 10 9.7 14 22 31 31 With Additional Impedance (use either DC type or AC type) Yaskawa Reactor Part Single Phase Output Capacity Number Input Load Motor Motor Power DC Type AC Type Current (A) Power FLA (kVA) (HP) URX000041 URX000295 0.5 1.26 0.98 2.1 URX000041 URX000299 1 2.4 1.7 3.8 05P00620-0110 URX000303 1.5 3.4 2.5 5.5 05P00652-0213 URX000308 2 3.9 3 6.7 URX000048 URX000312 3 5.5 4.3 9.5 URX000053 URX000316 3 5.5 4.7 10 URX000052 URX000316 3 5.5 4.6 10 URX000052 URX000316 5 8.7 7 15 URX000055 URX000324 7.5 12.7 9.9 22 05P00620-0123 URX000327 10 16 14 31 URX000061 URX000327 10 16 13 28 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 249 Specifications Table A.16 Sizing Method A, 480 V Single-Phase Input (-5% to +10%), 400 V Three-Phase Motor A A.4 Drive Derating Data With Additional Impedance (use either DC type or AC type) Without Additional Impedance Drive Model Output Capacity Single Phase Input Load Motor FLA Power (kVA) Current (A) 4A0058 4A0072 4A0088 4A0103 4A0139 4A0165 4A0208 4A0250 4A0296 4A0362 Motor Power (HP) 10 15 15 15 30 30 50 60 60 75 16 24 24 24 46 46 75 89 89 110 14 20 20 20 38 39 62 74 75 93 30 43 44 45 84 85 136 162 165 205 4A0414 4A0515 4A0675 100 100 125 143 143 179 122 125 157 267 275 345 Yaskawa Reactor Part Number DC Type DC Link Choke Built-in Output Capacity Single Phase Input Load Motor FLA Power (kVA) Current (A) URX000332 URX000336 URX000336 URX000335 URX000341 URX000341 URX000347 URX000347 URX000350 URX000353 Motor Power (HP) 15 20 20 20 30 30 50 60 75 100 24 31 31 31 46 46 75 89 110 143 19 24 24 25 36 37 59 70 87 115 41 52 52 54 80 81 130 154 192 251 URX000356 URX000353 URX000360 125 100 150 179 143 207 143 116 169 314 255 371 AC Type Table A.17 Sizing Method A, 600 V Single-Phase Input (-5% to +10%), 575 V Three-Phase Motor Without Additional Impedance Drive Model 5A0003 5A0004 5A0006 5A0009 5A0011 5A0017 5A0022 5A0027 5A0032 5A0041 5A0052 5A0062 5A0077 5A0099 5A0125 5A0145 5A0192 5A0242 250 Output Capacity Motor Power (HP) 1 1.5 2 3 2 5 5 7.5 7.5 10 15 20 25 30 40 40 60 75 Single Phase Input Load Motor FLA Power (kVA) Current (A) 1.7 2.4 2.7 3.9 2.7 6.1 6.1 9 9 11 17 22 27 32 41 41 62 77 2 2.7 4 5.4 4.1 9.1 9.2 14 14 14 19 27 32 38 49 49 74 91 3.5 4.8 7 9.5 7.1 16 16 24 24 24 34 47 57 66 86 86 130 159 With Additional Impedance (use either DC type or AC type) Yaskawa Reactor Part Single Phase Output Capacity Number Input Load Motor Motor Power DC Type AC Type Current (A) Power FLA (kVA) (HP) 05P00620-0110 URX000303 1.5 2.4 2.6 4.6 URX000044 URX000306 2 2.7 2.9 5 05P00652-0213 URX000308 3 3.9 4.3 7.6 URX000049 URX000313 5 6.1 6.5 11 05P00652-0213 URX000308 3 3.9 4.4 7.7 URX000048 URX000316 5 6.1 7.1 12 URX000053 URX000320 7.5 9 10 18 URX000055 URX000324 10 11 13 23 URX000055 URX000324 10 11 13 23 URX000326 15 17 18 32 URX000326 15 17 19 32 URX000335 25 27 31 54 URX000338 30 32 36 64 DC Link Choke URX000338 30 32 37 64 Built-in URX000344 50 52 58 102 URX000344 50 52 58 102 URX000347 75 77 87 152 URX000347 75 77 87 152 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide A.4 Drive Derating Data n Single-Phase Input Sizing Method B (86% Maximum Power of Connected Motor Size) Use single-phase input Sizing Method B for applications requiring a maximum of 86% motor power, such as a fully loaded fan or pump that does not draw full power from motor or a fan or pump that is never run at full load. There is no overload capacity for Sizing Method B. Table A.18 Sizing Method B, 240 V Single-Phase Input (230 V to 240 V), 230 V Three-Phase Motor Drive Model 2A0004 2A0006 2A0008 2A0010 2A0012 2A0018 2A0021 2A0030 2A0040 2A0056 2A0069 2A0081 2A0110 2A0138 2A0169 2A0211 2A0250 2A0312 2A0360 2A0415 Output Capacity Motor Power (HP) Motor FLA 0.5 2.2 1 4.2 1 4.2 1.5 6 2 6.8 3 9.6 3 9.6 4 15.2 4 7.5 10 15 15 20 25 30 40 50 60 75 15.2 22 28 42 42 54 68 80 104 130 154 192 Single Phase Input Load Power (kVA) Current (A) 0.989 4.30 1.68 7.30 1.75 7.60 2.44 10.6 3.20 13.9 4.83 21.0 4.83 21.0 7.82 34.0 7.82 11.0 14.7 21.2 18.4 23.9 29.9 35.4 46.5 57.3 68.5 84.2 34.0 48.0 64.0 92.0 80.0 104 130 154 202 249 298 366 Table A.19 Sizing Method B, 480 V Single-Phase Input (460 V to 480 V), 460 V Three-Phase Motor 4A0002 4A0004 4A0005 4A0007 4A0009 4A0011 4A0018 4A0023 4A0031 4A0038 4A0044 4A0058 4A0072 4A0088 4A0103 4A0139 4A0165 4A0208 4A0250 4A0296 Output Capacity Motor Power (HP) Motor FLA 0.3 0.76 1 2.1 1.5 3 2 3.4 3 4.8 3 4.8 5 7.6 5 7.6 10 14 10 14 15 21 20 27 25 34 25 34 25 34 50 65 50 65 60 77 75 96 100 124 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Single Phase Input Load Power (kVA) Current (A) 0.96 2.10 1.98 4.30 2.85 6.20 3.59 7.80 5.15 11.2 5.15 11.2 8.33 18.1 8.33 18.1 16.1 35.0 16.1 35.0 22.6 49.2 23.9 52.0 30.4 66.0 30.4 66.0 30.8 67.0 58.0 126 58.9 128 70.4 153 86.5 188 114 248 Specifications Drive Model A 251 A.4 Drive Derating Data Drive Model 4A0362 4A0414 4A0515 4A0675 Output Capacity Motor Power (HP) 125 150 150 200 Single Phase Input Load Motor FLA 156 180 180 240 Power (kVA) 142 168 171 225 Current (A) 308 365 371 489 Table A.20 Sizing Method B, 600 V Single-Phase Input (575 V to 600 V), 575 V Three-Phase Motor Drive Model 5A0003 5A0004 5A0006 5A0009 5A0011 5A0017 Output Capacity Motor Power (HP) Motor FLA 1 1.7 2 2.7 3 3.9 5 6.1 3 3.9 7.5 9 5A0022 5A0027 5A0032 5A0041 5A0052 5A0062 5A0077 5A0099 5A0125 5A0145 5A0192 5A0242 7.5 10 10 20 20 30 40 40 60 60 100 100 9 11 11 22 22 32 41 41 62 62 99 99 Single Phase Input Load Power (kVA) Current (A) 1.78 3.10 2.93 5.10 4.37 7.60 6.90 12.0 4.95 8.60 11.4 19.8 11.4 16.1 16.1 24.0 24.0 36.8 46.0 47.2 68.4 68.4 113 113 19.8 28.0 28.0 41.8 41.8 64.0 80.0 82.0 119 119 196 196 u Temperature Derating To ensure the maximum performance life, the drive output current must be derated as shown in Figure A.1 when the drive is installed in areas with high ambient temperature or if drives are mounted side-by-side in a cabinet. In order to ensure reliable drive overload protection, set parameters L8-12 and L8-35 according to the installation conditions. n Parameter Settings No. L8-12 L8-35 Name Description Ambient Adjust the drive overload (oL2) protection level when the drive is installed Temperature Setting in an environment that exceeds its ambient temperature rating. 0: IP00/Open-Chassis Enclosure Installation Method 1: Side-by-Side Mounting Selection 2: IP20/NEMA Type 1 Enclosure 3: Finless Drive or External Heatsink Installation Range Def. -10 to +50 +40 °C 0 to 3 <1> <1> Default setting is determined by drive model. Setting 0: (Models 2A0250 to 2A0415 and 4A0208 to 4A0675) Setting 2: (Models 2A0004 to 2A0211, 4A0002 to 4A0165, and 5A0003 to 5A0242). IP00/Open-Chassis Enclosure Drive operation between -10 °C and +50 °C allows 100% continuous current without derating. Side-by-Side Mounting Drive operation between -10 °C and +30 °C allows 100% continuous current without derating. Operation between +30 °C and +50 °C requires output current derating. IP20/NEMA Type 1 Enclosure Drive operation between -10 °C and +40 °C allows 100% continuous current without derating. Operation between +40 °C and +50 °C requires output current derating. 252 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide A.4 Drive Derating Data External Heatsink Installation, Finless Drive Drive operation between -10 °C and +40 °C allows 100% continuous current without derating. Operation between +40 °C and +50 °C requires output current derating. L8-35 = 0: IP00/Open-Chassis Enclosure Drive Rating (%) L8-35 = 2: IP20/NEMA Type 1 Enclosure L8-35 = 3: External Heatsink lnstallation 100 85 70 55 L8-35 = 1: Side-by-Side Mounting 0 -10 30 40 50 L8-12 (Ambient temp: °C) Figure A.1 Ambient Temperature and Installation Method Derating u Altitude Derating Specifications The drive standard ratings are valid for installation altitudes up to 1000 m. For installations from 1000 m to 3000 m, the drive rated voltage and the rated output current must be derated for 0.2% per 100 m. A YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 253 A.4 Drive Derating Data This Page Intentionally Blank 254 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Appendix: B Parameter List This appendix contains a full listing of all parameters and settings available in the drive. B.1 B.2 B.3 B.4 B.5 B.6 B.7 B.8 B.9 B.10 B.11 B.12 B.13 B.14 B.15 A: INITIALIZATION PARAMETERS....................................................................256 B: APPLICATION.................................................................................................258 C: TUNING............................................................................................................263 D: REFERENCES.................................................................................................266 E: MOTOR PARAMETERS..................................................................................269 F: OPTIONS.........................................................................................................272 H PARAMETERS: MULTI-FUNCTION TERMINALS..........................................276 L: PROTECTION FUNCTION...............................................................................289 N: SPECIAL ADJUSTMENT................................................................................296 O: OPERATOR-RELATED SETTINGS................................................................298 P: PUMP PARAMETERS.....................................................................................301 Q: PID CONTROLLER PARAMETERS...............................................................316 S: SPECIAL APPLICATION.................................................................................320 T: MOTOR TUNING..............................................................................................325 U: MONITORS......................................................................................................326 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 255 B.1 A: Initialization Parameters B.1 A: Initialization Parameters Table B.1 Symbols and Icons Used in Parameter Descriptions Symbol V/f OLV Description Parameter is ONLY available when operating the drive with V/f control. Parameter is ONLY available when operating the drive with Open Loop Vector control. Parameter can be changed during run. The A parameter group creates the operating environment for the drive. This includes the parameter Access Level, Motor Control Method, Password, User Parameters and more. u A1: Initialization No. (Addr. Hex) A1-00 (0100) Name Language Selection <1> A1-01 (0101) Access Level Selection <2> LCD Display Select Language 0: English (Japanese) 1: 2: Deutsch 3: Français 4: Italiano 5: Español 6: Português 7: 0: English 1: Japanese 2: German 3: French 4: Italian 5: Spanish 6: Portuguese 7: Chinese 0: View and set A1-01 and A1-04. Uo-oo parameters can also be viewed. 1: User Parameters (access to parameters selected by the user, A2-01 to A2-32) 2: Advanced Access (access to view and set all parameters) 3: Lock parameters Init Parameters 0: No initialization 0: No Initialize 1110: User Initialize (parameter values must be stored using 1110: User Initialize parameter o2-03) 2220: 2-Wire Initial 2220: 2-Wire initialization 3330: 3-Wire Initial 3330: 3-Wire initialization 5550: Term->Cntrl Int 5550: Terminal->Control Initialize 6008: Pressure Control 6008: Pressure Control 6009: Pump down level 6009: Pump down level 6010: Geothermal 6010: Geothermal mode mode 6011: VTC pressure control 6011: VTC Pressure Ctl 7770: General purpose 7770: General purpose When the value set into A1-04 does not match the value set into Enter Password A1-05, parameters A1-01 through A1-03 and A2-01 through A2-33 cannot be changed. Access Level 0: Operation Only 1: User Parameters 2: Advanced Level A1-03 (0103) Initialize Parameters A1-04 (0104) Password A1-05 (0105) Password Setting Select Password Application Preset Application Sel 0: General 8: Pressure Control 9: Pump Down Level 10: Geothermal Mode 11: VTC Pressure Ctl A1-06 (0127) Description 0: General-purpose 8: Pressure control 9: Pump down level 10: Geothermal mode 11: VTC pressure control Note: Values Page Default: 0 Range: 0 to 7 – Default: 2 Range: 0 to 3 – Default: 0 Range: 0 to 5550; 6008 to 6011; 7770 Default: 0000 Min.: 0000 Max.: 9999 Default: 0000 Min.: 0000 Max.: 9999 Default: 0 Range: 0; 8 to 11 149 – – – This parameter is not settable. It is used as a monitor only. <1> Parameter setting value is not reset to the default value when the drive is initialized. <2> Default setting value is dependent on the Initialization parameter A1-03. 256 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.1 A: Initialization Parameters u A2: User Parameters No. (Addr. Hex) Name A2-01 to A2-32 User Parameters 1 to 32 (0106 to 0125) A2-33 (0126) User Parameter Automatic Selection LCD Display Description Values Page User Param 1 - 32 Recently edited parameters are listed here. The user can also select Default: <1> parameters to appear here for quicker access. Range: b1-01 to S6-07 – User Parms Sel 0: Disabled 1: Enabled 0: A2-01 to A2-32 are reserved for the user to create a list of User Parameters. Default: 0 1: Save history of recently viewed parameters. Recently edited Range: 0, 1 parameters will be saved to A2-17 through A2-32 for quicker access. – Parameter List <1> Default setting value is dependent on the Initialization parameter A1-03. B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 257 B.2 b: Application B.2 b: Application Application parameters configure the source of the Run command, DC Injection Braking, Speed Search, timer functions, PID control, the Dwell function, Energy Savings, and other application-related settings. u b1: Operation Mode Selection No. (Addr. Hex) Name LCD DIsplay b1-01 (0180) Frequency Reference Selection 1 Ref Source 1 0: Operator 1: Analog Input 2: Serial Com 3: Option PCB 4: Pulse Input 5: Geothermal b1-02 (0181) Run Command Selection 1 Run Source 1 0: Operator 1: Digital Inputs 2: Communication 3: Option PCB b1-03 (0182) Stopping Method Selection Stopping Method 0: Ramp to Stop 1: Coast to Stop 2: DCInj to Stop 3: Coast w/Timer b1-04 (0183) Reverse Operation Selection Run Command Selection in Programming Mode b1-08 (0187) b1-11 Coast to Stop with (01DF) Timer Time Description 0: HOA keypad 1: Analog input terminals 2: MEMOBUS/Modbus communications 3: Option PCB 4: Pulse input (terminal RP) 5: Geothermal Mode (Frequency reference dependent on temperature input (H3-0o = 21) 0: HOA keypad 1: Digital input terminals 2: MEMOBUS/Modbus communications 3: Option PCB Values Page Default: 0 Range: 0 to 5 151 Default: 0 Range: 0 to 3 153 0: Ramp to stop 1: Coast to stop 2: DC Injection Braking to stop 3: Coast with timer Default: 1 Range: 0 to 3 154 Reverse Oper 0: Reverse Enabled 1: Reverse Disabled 0: Reverse enabled 1: Reverse disabled Default: 1 Range: 0, 1 RUN dur PRG Mode 0: Run Disabled@PRG 1: ModeRun Enabled@PRG 2: Prg only @ Stop 0: Run command is not accepted while in Programming Mode. 1: Run command is accepted while in Programming Mode. Default: 0 2: Prohibit entering Programming Mode during run. Range: 0 to 2 Coast Timer Sets the amount of time that the drive will disallow the reapplication of the Run command after the Run command is lost. When set to 0.0, a combination of C1-02 and the output frequency will determine the length of time. Rotation Sel 0: Standard 1: SwitchPhaseOrder Phase Order Selection b1-17 (01C6) Cmd @ Pwr On Run Command at Power Run 0: Cycle Ext Run Up 1: Accept Ext Run – Default: 120.0 s Min.: 0.0 Max.: 6000.0 – 0: Standard 1: Switch phase order (reverses the direction of the motor) Default: 0 Range: 0, 1 – 0: Disregarded. A new Run command must be issued after power up. 1: Allowed. Motor will start immediately after power up if a Run command is already enabled. Default: 1 Range: 0, 1 – Note: b1-14 (01C3) – This parameter is effective only when b1-03 is set to 3 (Coast to Stop w/Timer). u b2: DC Injection Braking and Short Circuit Braking No. (Addr. Hex) Name LCD Display b2-01 (0189) DC Injection Braking Start Frequency DCInj Start Freq b2-02 (018A) DC Injection Braking Current DCInj Current b2-03 (018B) DC Injection Braking Time at Start DCInj Time@Start 258 Description Values Sets the frequency at which DC Injection Braking starts when Default: 0.5 Hz “Ramp to stop” (b1-03 = 0) is selected. Min.: 0.0 Max.: 10.0 Sets the DC Injection Braking current as a percentage of the Default: 50% drive rated current. Min.: 0 Max.: 100 Sets DC Injection Braking time at start. Disabled when set to Default: 0.00 s 0.00 seconds. Min.: 0.00 Max.: 10.00 Page – – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.2 b: Application No. (Addr. Hex) Name LCD Display b2-04 (018C) DC Injection Braking Time at Stop DCInj Time@Stop b2-08 (0190) Magnetic Flux Compensation Value Field Comp Description Sets DC Injection Braking time at stop. Values Default: 0.50 s Min.: 0.00 Max.: 10.00 OLV Default: 0% Sets the magnetic flux compensation as a percentage of the no- Min.: 0 Max.: 1000 load current value (E2-03). Page – – u b3: Speed Search Name LCD Display Description Values b3-01 (0191) Speed Search Selection SpdSrch at Star 0: Disabled at Start 1: Enabled 0: Disabled 1: Enabled b3-02 (0192) Speed Search Deactivation Current SpdSrch DeactCur Sets the current level at which the speed is assumed to be Default: 120% detected and Speed Search is ended. Set as a percentage of the (V/f) drive rated current. 100% (OLV) Min.: 0 Max.: 200 b3-03 (0193) Speed Search Deceleration Time SpdSrch Dec Time b3-04 (0194) V/f Gain during Speed Search b3-05 (0195) Speed Search Delay Time b3-06 (0196) Output Current 1 during Srch Im Lvl1 Speed Search b3-07 (0197) Output Current 2 during Srch Im Lvl2 Speed Search (Speed Estimation Type) b3-08 (0198) Current Control Gain during Speed Search (Speed Estimation Type) b3-10 (019A) Speed Search Detection Srch Detect Comp Compensation Gain b3-12 (019C) Minimum Current Detection Level during Srch I Deadband Speed Search Bidir Search Sel Bi-Directional Speed 0: Disabled Search Selection 1: Enabled b3-14 (019E) Default: 0 Range: 0, 1 Page 156 – Sets output frequency reduction time during Speed Search. Default: 2.0 s Min.: 0.1 Max.: 10.0 – SpdSrch V/f Determines how much to lower the V/f ratio during Speed Search. Output voltage during Speed Search equals the V/f setting multiplied by b3-04. Default: <1> Min.: 10% Max.: 100% – Search Delay When using an external contactor on the output side, b3-05 Default: 0.2 s delays executing Speed Search after a momentary power loss to Min.: 0.0 allow time for the contactor to close. Max.: 100.0 Srch ACR P Gain b3-17 (01F0) Speed Search Restart Current Level SrchRestart Lvl b3-18 (01F1) Speed Search Restart Detection Time SrchRestart Time b3-19 (01F2) Number of Speed Search Restarts Num of SrchRestr b3-24 (01C0) Speed Search Method Selection SpdSrch Method 0: CurrentDetection 1: Speed Estimation Sets the current injected to the motor at the beginning of Speed Default: <1> Estimation Speed Search. Set as a coefficient for the motor rated Min.: 0.0 current. Max.: 2.0 Sets the amount of output current during Speed Estimation Default: <1> Speed Search as a coefficient for the no-load current. Min.: 0.0 Max.: 5.0 Sets the proportional gain for the current controller during Speed Default: 0.8 Search. Min.: 0.00 Max.: 6.00 – – – – Sets the gain which is applied to the speed detected by Speed Estimation Speed Search before the motor is reaccelerated. Increase this setting if ov occurs when performing Speed Search after a relatively long period of baseblock. Sets the minimum current detection level during Speed Search. Default: 1.05 Min.: 1.00 Max.: 1.20 – Default: 6.0 Min.: 2.0 Max.: 10.0 – 0: Disabled (uses the direction of the frequency reference) 1: Enabled (drive detects which way the motor is rotating) Default: 1 Range: 0, 1 – Sets the Speed Search restart current level as a percentage of the Default: 150% drive rated current. Min.: 0 Max.: 200 Sets the time to detect Speed Search restart. Default: 0.10 s Min.: 0.00 Max.: 1.00 Sets the number of times the drive can attempt to restart when Default: 3 performing Speed Search. Min.: 0 Max.: 10 0: Current Detection Default: 0 1: Speed Estimation Range: 0, 1 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide – – – – Parameter List No. (Addr Hex.) B 259 B.2 b: Application No. (Addr Hex.) Name LCD Display b3-25 (01C8) Speed Search Wait Time SpdSrch WaitTime b3-27 (01C9) Start Speed Search Select Start srch sel 0: Start from 0 1: Start Fref>Fmin Description Sets the time the drive must wait between each Speed Search restart attempt. Values Default: 0.5 s Min.: 0.0 Max.: 30.0 Selects a condition to activate Speed Search Selection at Start (b3-01) or External Speed Search Command 1 or 2 from the Default: 0 multi-function input. Range: 0, 1 0: Triggered when a Run command is issued (normal). 1: Triggered when an external baseblock is released. Page – – <1> Default setting is dependent on parameter o2-04, Drive Model Selection. u b4: Timer Function No. (Addr. Hex) Name LCD Display b4-01 (01A3) Timer Function OnDelay Time Delay-ON Timer b4-02 (01A4) Timer Function OffDelay Time Delay-OFF Timer Description Sets the on-delay and off-delay times for a digital timer output (H2-oo=12). The output is triggered by a digital input programmed to H1-oo=18). Values Default: 0.0 s Min.: 0.0 Max.: 3000.0 Default: 0.0 s Min.: 0.0 Max.: 3000.0 Page – – u b5: PID Control No. (Addr. Hex) b5-01 (01A5) b5-02 (01A6) Name LCD Display PID Function Setting PID Mode 0: Disabled 1: Enabled D=Fdbk Proportional Gain Setting (P) PID Gain b5-03 (01A7) Integral Time Setting (I) PID I Time b5-04 (01A8) Integral Limit Setting PID I Limit b5-05 (01A9) Derivative Time (D) PID D Time Description 0: Disabled 1: Enabled (PID output becomes output frequency reference, deviation D controlled) Sets the proportional gain of the PID controller. PID Limit Page Default: 1 Range: 0, 1 – Default: 2.00 Min.: 0.00 Max.: 25.00 – Default: 3.0 s Min.: 0.0 Max.: 360.0 – Sets the maximum output possible from the integrator as a percentage of the maximum output frequency. Default: 100.0% Min.: 0.0 Max.: 100.0 – Sets D control derivative time. Default: 0.00 s Min.: 0.00 Max.: 10.00 – Sets the integral time for the PID controller. b5-06 (01AA) PID Output Limit Values Sets the maximum output possible from the entire PID controller Default: 100.0% as a percentage of the maximum output frequency. Min.: 0.0 Max.: 100.0 – b5-07 (01AB) PID Offset Adjustment PID Offset Applies an offset to the PID controller output. Set as a percentage of the maximum output frequency. Default: 0.0% Min.: -100.0 Max.: 100.0 – b5-08 (01AC) PID Primary Delay Time Constant PID Delay Time Sets a low pass filter time constant on the output of the PID controller. Default: 0.00 s Min.: 0.00 Max.: 10.00 – b5-09 PID Output Level (01AD) Selection Output Level Sel 0: Direct Acting 1: Inverse Acting 0: Direct acting 1: Inverse acting Default: 0 Range: 0, 1 – Sets the gain applied to the PID output. Default: 1.00 Min.: 0.00 Max.: 25.00 – b5-10 (01AE) PID Output Gain Setting Output Gain 260 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.2 b: Application Name b5-11 PID Output Reverse (01AF) Selection LCD Display Output Rev Sel 0: 0 limit 1: Reverse b5-12 (01B0) Fdbk 4-20mA Det Disabled Feedback Loss 4 to 20 0: Alarm only mA Detection Selection 1: 2: Fault 3: Run At b5-13 b5-13 (01B1) Feedback Loss Goto Frequency b5-14 (01B2) FdbkLossGotoFreq Feedback Loss of Prime FdbkLoss LOP Lvl Level Description 0: Negative PID output triggers zero limit. 1: Rotation direction reverses with negative PID output. Note: When using setting 1, make sure reverse operation is permitted by b1-04. Performs a 4 to 20 mA wire break detection on the analog input that is programmed for PID feedback. 0: Disabled 1: Alarm only 2: Fault 3: Run at b5-13 Sets the speed at which the drive will run if a 4 to 20 mA wire break is detected on the PID Feedback and when b5-12 is set to 3 (Run at b5-13). Values Default: 0 Range: 0, 1 – Default: 2 Range: 0 to 3 – Default: 0.0 Hz Min.: 0.0 Max.: 400.0 – Detects loss of prime in the pump when a wire break condition has occurred. Default: 0.0 A When the measured quantity determined by P1-18 (output current, kilowatts, or power) drops below this level for the time <1> set in P1-20 and the output frequency is at the level set in b5-13, Min.: 0.0 a “Loss of Prime” condition occurs. Max.: 1000.0 The drive responds to the “Loss of Prime” condition depending on the setting of P1-22, Loss of Prime Selection. Sets the acceleration and deceleration time to PID setpoint. Page Default: 0.0 s Min.: 0.0 Max.: 6000.0 – b5-17 (01B5) PID Accel/Decel Time b5-34 (019F) PID Output Lower Limit PID Out Low Lim Sets the minimum output possible from the PID controller as a Default: 0.00% percentage of the maximum output frequency. Min.: -100.00 Max.: 100.00 – b5-35 (01A0) PID Input Limit PID Input Limit Limits the PID control input (deviation signal) as a percentage Default: of the maximum output frequency. Acts as a bipolar limit. 1000.0% Min.: 0.0 Max.: 1000.0 – b5-39 (01FF) PID Setpoint Display Digits PID UsrDspDigits 0: No Dec (XXXXX) 1: 1 Dec (XXXX.X) 2: 2 Dec (XXX.XX) 3: 3 Dec (XX.XXX) 0: No decimal places 1: One decimal place 2: Two decimal places 3: Three decimal places Default: 1 Range: 0 to 3 – b5-40 (017F) Frequency Reference Fref Mon Sel@PID Monitor Content during 0: Fref Mon w PID PID 1: Fref Mon w/o PID 0: Display the frequency reference (U1-01) after PID compensation has been added. 1: Display the frequency reference (U1-01) before PID compensation has been added. Default: 0 Range: 0, 1 – 0: No Unit 1: Pounds per square inch 2: Pascals 3: Bar 4: Inch of Water 5: Inch of Mercury 6: Feet 7: Meters 8: Degrees Fahrenheit 9: Degrees Celsius 10: Percent 25: Flow (use P6-04) Default: 0 Range: 0 to 10; 25 – Default: 0 Range: 0 to 3 – b5-41 (0160) b5-42 (0161) b5-43 (0162) PI Output 2 Unit Selection PID Acc/Dec Time PI Out2 Unit Sel 0: No Unit 1: PSI :lb/SqrInch 2: Pa:Pascals 3: Bar:Bar 4: "WC: InchOfWater 5: "Hg:Inch Mercury 6: ft: feet 7: m: meters 8: °F:DegFarenheit 9: °C:DegCelsius 10: %: Percent 25: Flow (use P6-04) PI Out2 Calc Mode Linear PI Output 2 Calculation 0: 1: Square root Mode 2: 1/f2 3: 1/f3 PI Output 2 Monitor Max Upper 4 Digits PI Out2 MonMax U 0: Linear - the monitor displays PID output 1: Square root - the monitor displays square root PID output 2: Quadratic - the monitor displays 1/(PID output)2 3: Cubic - the monitor displays 1/(PID output)3 Note: Used for U5-14 and U5-15 only. Sets the upper 4 digits of the maximum monitor value. Used with b5-44 to set maximum monitor value of U5-14 and Default: 0 Min.: 0 U5-15 at maximum frequency. Max.: 9999 Note: Used for U5-14 and U5-15 only. – – Parameter List No. (Addr. Hex) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 261 B.2 b: Application No. (Addr. Hex) b5-44 (0163) b5-45 (0164) b5-47 (017D) Name LCD Display PI Output 2 Monitor Max Lower 4 Digits PI Out2 MonMax L PI Output 2 Monitor Minimum PI Out2 MonMin Reverse Operation Selection 2 by PID Output Output Rev Sel2 Description Values Sets the lower 4 digits of the maximum monitor value. Used with b5-43 to set maximum monitor value of U5-14 and Default: 0 Min.: 0 U5-15 at maximum frequency. Max.: 99.99 Note: Used for U5-14 and U5-15 only. Sets the minimum display value at zero speed. This function is effective when b5-42 is set to 0 (Linear output Default: 0 Min.: 0 mode). Max.: 999.9 Note: Used for U5-14 and U5-15 only. 0: Zero limit when PID output is a negative value. Default: 1 1: Reverse operation when PID output is a negative value Range: 0, 1 (Zero limit if the reverse operation is prohibited by b1-04). Page – – – <1> Unit text is set by P1-18, Prime Loss Detection Method. u b6: Dwell Function No. (Addr. Hex) Name Description b6-01 (01B6) Dwell Reference at Start Dwell Ref @Start b6-02 (01B7) Dwell Time at Start b6-03 (01B8) Dwell Reference at Stop Dwell Ref @Stop b6-04 (01B9) Dwell Time at Stop Dwell Time @Start Dwell Time @Stop Values Parameters b6-01 and b6-02 set the frequency to hold and the Default: 0.0 Hz time to maintain that frequency at start. Min.: 0.0 Max.: 400.0 Default: 0.0 s Min.: 0.0 Max.: 10.0 Parameters b6-03 and b6-04 set the frequency to hold and the Default: 0.0 Hz time to maintain that frequency at stop. Min.: 0.0 Max.: 400.0 Default: 0.0 s Min.: 0.0 Max.: 10.0 Page – – – – u b8: Energy Saving No. (Addr. Hex) Name LCD Display b8-01 Energy Saving Control Energy Save Sel 0: Disabled (01CC) Selection 1: Enabled b8-02 (01CD) Energy Saving Gain Energy Save Gain b8-03 (01CE) Energy Saving Control Energy Save F.T Filter Time Constant Description 0: Disabled 1: Enabled OLV Sets the gain used for Energy Saving. OLV Sets a time constant for Energy Saving. Values Page Default: 0 Range: 0, 1 – Default: 0.7 Min.: 0.0 Max.: 10.0 – Default: <1> Min.: 0.00 s Max.: 10.00 s – V/f Default: <1> <2> Determines the level of maximum motor efficiency. Setting Min.: 0.00 range is 0.0 to 2000.0 for drives 3.7 kW and smaller. The display Max.: 655.00 resolution depends on the rated output power of the drive. b8-04 (01CF) Energy Saving Coefficient Value Energy Save COEF b8-05 (01D0) Power Detection Filter Time kW Filter Time Sets a time constant filter for output power detection. b8-06 (01D1) Search Operation Voltage Limit Search V Limit V/f Default: 0% Sets the limit for the voltage search operation as a percentage of Min.: 0 Max.: 100 the motor rated voltage. V/f Default: 20 ms Min.: 0 Max.: 2000 – – – <1> Default setting is dependent on parameter o2-04, Drive Model Selection. <2> Parameter value changes automatically if E2-11 is manually changed or changed by Auto-Tuning. 262 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.3 C: Tuning B.3 C: Tuning C parameters are used to adjust the acceleration and deceleration times, S-curves, torque compensation, and carrier frequency selections. u C1: Acceleration and Deceleration Times No. Name (Addr. Hex) C1-01 (0200) Acceleration Time 1 Accel Time 1 C1-02 (0201) Deceleration Time 1 Decel Time 1 C1-03 (0202) Acceleration Time 2 Accel Time 2 C1-04 (0203) Deceleration Time 2 Decel Time 2 C1-05 (0204) Acceleration Time 3 Accel Time 3 Sets the time to accelerate from 0 to maximum frequency. C1-06 (0205) Deceleration Time 3 Decel Time 3 Sets the time to decelerate from maximum frequency to 0. C1-09 (0208) Fast Stop Time Fast Stop Time C1-10 (0209) Accel/Decel Time Setting Units Acc/Dec Units 0: 0.01 Seconds 1: 0.1 Seconds 0: 0.01 s (0.00 to 600.00 s) 1: 0.1 s (0.0 to 6000.0 s) C1-11 (020A) Accel/Decel Time Switching Frequency Acc/Dec SW Freq Sets the frequency to switch between accel/decel time settings Default: 0.0 Hz Min.: 0.0 Max.: 400.0 LCD Display Description Sets the time to accelerate from 0 to maximum frequency. Values Page Default: 20.0 s Min.: 0.0 Max.: 6000.0 <1> 157 Sets the time to decelerate from maximum frequency to 0. 157 Sets the time to accelerate from 0 to maximum frequency. 157 Sets the time to decelerate from maximum frequency to 0. Sets the time for the Fast Stop function. Default: 10.0 s Min.: 0.0 Max.: 6000.0 <1> 157 Default: 10.0 s Min.: 0.0 Max.: 6000.0 <1> – Default: 1 Range: 0, 1 – – <1> Setting range value is dependent on parameter C1-10, Accel/Decel Time Setting Units. When C1-10 = 0 (units of 0.01 seconds), the setting range becomes 0.00 to 600.00 seconds. u C2: S-Curve Characteristics Name C2-01 (020B) S-Curve Characteristic at Accel Start SCrv Acc @ Start C2-02 (020C) S-Curve Characteristic at Accel End SCrv Acc @ End C2-03 (020D) S-Curve Characteristic at Decel Start SCrv Dec @ Start C2-04 (020E) S-Curve Characteristic at Decel End SCrv Dec @ End LCD Display Description Values The S-curve can be controlled at the four points shown below. Default: 0.20 s Min.: 0.00 ON OFF Max.: 10.00 Run Command Output Frequency Default: 0.20 s C2-02 C2-03 Min.: 0.00 Max.: 10.00 C2-01 C2-04 Default: 0.20 s Time Min.: 0.00 Max.: 10.00 Default: 0.00 s Min.: 0.00 Max.: 10.00 Page – – – – Parameter List No. (Addr. Hex) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 263 B.3 C: Tuning u C3: Slip Compensation No. (Addr. Hex) C3-01 (020F) C3-02 (0210) Name LCD Display Slip Compensation Gain Slip Comp Slip Compensation Primary Delay Time Slip Comp Time C3-03 (0211) Slip Compensation Limit Slip Comp Limit C3-04 (0212) Slip Compensation Selection during Regeneration Slip Comp Regen 0: Disabled 1: Above 6 Hz 2: Lowst possbl spd C3-05 (0213) Output Voltage Limit Operation Selection Output V Lim Sel 0: Disabled 1. Enabled Description Values Sets the gain for the motor slip compensation function used for Default: 0.0 (V/ motor 1. f) 1.0 (OLV) Min.: 0.0 Max.: 2.5 Adjusts the slip compensation function delay time used for Default: 2000 ms motor 1. (V/f) 200 ms (OLV) Min.: 0 Max.: 10000 Sets an upper limit for the slip compensation function as a Default: 200% percentage of motor rated slip for motor 1 (E2-02). Min.: 0 Max.: 250 0: Disabled. Default: 0 1: Enabled above 6 Hz Range: 0 to 2 2: Enabled whenever slip compensation is possible. Page – – – – OLV 0: Disabled. 1: Enabled. Automatically decreases motor flux when output voltage saturation is reached. Default: 0 Range: 0, 1 – u C4: Torque Compensation No. Name (Addr. Hex) C4-01 (0215) Torque Compensation Gain C4-02 (0216) LCD Display Torq Comp Gain Description Values Sets the gain for the automatic torque (voltage) boost function Default: 1.00 and helps to produce better starting torque. Used for motor 1. Min.: 0.00 Max.: 2.50 Sets the torque compensation filter time. – Default: 0.0% Min.: 0.0 Max.: 200.0 – Default: 0.0% Min.: -200.0 Max.: 0.0 – Torq Comp Time C4-03 (0217) Torque Compensation at Forward Start F TorqCmp@start Sets torque compensation at forward start as a percentage of motor torque. C4-04 (0218) Torque Compensation at Reverse Start R TorqCmp@start Sets torque compensation at reverse start as a percentage of motor torque. C4-05 (0219) Torque Compensation Time Constant TorqCmp Delay T OLV Default: 10 ms Sets the time constant for torque compensation at forward start Min.: 0 Max.: 200 and reverse start (C4-03 and C4-04). C4-06 (021A) Torque Compensation Primary Delay Time 2 Start Torq Time Sets the torque compensation time 2. 264 OLV OLV – Default: 200 ms (V/f) 20 ms (OLV) Min.: 0 Max.: 60000 Torque Compensation Primary Delay Time 1 OLV Page Default: 150 ms Min.: 0 Max.: 10000 – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.3 C: Tuning u C6: Carrier Frequency No. (Addr. Hex) Name LCD Display C6-02 (0224) Carrier Frequency Selection CarrierFreq Sel 1: 2.0 kHz 2: 5.0 kHz 3: 8.0 kHz 4: 10.0 kHz 5: 12.5 kHz 6: 15.0 kHz 7: Swing PWM1 8: Swing PWM2 9: Swing PWM3 A: Swing PWM4 F: Program C6-03 (0225) Carrier Frequency Upper Limit CarrierFreq Max C6-04 (0226) Carrier Frequency Lower Limit CarrierFreq Min Carrier Frequency Proportional Gain 1: 2.0 kHz 2: 5.0 kHz (4.0 kHz) 3: 8.0 kHz (6.0 kHz) 4: 10.0 kHz (8.0 kHz) 5: 12.5 kHz (10.0 kHz) 6: 15.0 kHz (12.0 kHz) 7: Swing PWM1 (Audible sound 1) 8: Swing PWM2 (Audible sound 2) 9: Swing PWM3 (Audible sound 3) A: Swing PWM4 (Audible sound 4) B to E: No setting possible F: User-defined (determined by C6-03 through C6-05) Determines the upper and lower limits for the carrier frequency. Carrier Frequency C6-03 C6-04 CarrierFreq Gain Output Frequency × (C6-05) × K Output Frequency E1-04 Max Output Frequency Values Page Default: 7 Range: 1 to 9; A, F – Default: 2.0 kHz Min.: 1.0 Max.: 15.0 – Default: 2.0 kHz Min.: 1.0 Max.: 15.0 – Default: 0 Min.: 0 Max.: 99 – Parameter List C6-05 (0227) Description B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 265 B.4 d: References B.4 d: References Reference parameters set the various frequency reference values during operation. u d1: Frequency Reference No. (Addr. Hex) d1-01 (0280) Name LCD Display Frequency Reference 1 Reference 1 Description Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Values Default: 0.00 Hz Min.: 0.00 Max.: 400.00 Page – <1> d1-02 (0281) Frequency Reference 2 Reference 2 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-03 (0282) Frequency Reference 3 Reference 3 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-04 (0283) Frequency Reference 4 Reference 4 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-05 (0284) Frequency Reference 5 Reference 5 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-06 (0285) Frequency Reference 6 Reference 6 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-07 (0286) Frequency Reference 7 Reference 7 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-08 (0287) Frequency Reference 8 Reference 8 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-09 (0288) Frequency Reference 9 Reference 9 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-10 (028B) Frequency Reference 10 Reference 10 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-11 (028C) Frequency Reference 11 Reference 11 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-12 (028D) Frequency Reference 12 Reference 12 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-13 (028E) Frequency Reference 13 Reference 13 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> 266 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.4 d: References No. (Addr. Hex) d1-14 (028F) Name LCD Display Frequency Reference 14 Reference 14 Description Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Values Default: 0.00 Hz Min.: 0.00 Max.: 400.00 Page – <1> d1-15 (0290) Frequency Reference 15 Reference 15 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-16 (0291) Frequency Reference 16 Reference 16 Sets the frequency reference for the drive. Setting units are determined by parameter o1-03. Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – <1> d1-17 (0292) Jog Frequency Reference Jog Reference Sets the Jog frequency reference. Setting units are determined Default: 6.00 Hz by parameter o1-03. Min.: 0.00 Max.: 400.00 – <1> <1> Range upper limit is determined by parameters d2-01, Frequency Reference Upper Limit, and E1-04, Maximum Output Frequency. u d2: Frequency Upper/Lower Limits No. (Addr. Hex.) Name LCD Display Description Setting Page d2-01 (0289) Frequency Reference Upper Limit Ref Upper Limit Sets the frequency reference upper limit as a percentage of the Default: 100.0% maximum output frequency. Min.: 0.0 Max.: 110.0 – d2-02 (028A) Frequency Reference Lower Limit Ref Lower Limit Sets the frequency reference lower limit as a percentage of the Default: 0.0% maximum output frequency. Min.: 0.0 Max.: 110.0 – d2-03 (0293) Master Speed Reference Ref1 Lower Limit Lower Limit Sets the lower limit for frequency references from analog inputs Default: 0.0% as a percentage of the maximum output frequency. Min.: 0.0 Max.: 110.0 – u d3: Jump Frequency No. (Addr. Hex) Name LCD Display Jump Frequency 1 Jump Freq 1 d3-02 (0295) Jump Frequency 2 Jump Freq 2 d3-03 (0296) Jump Frequency 3 Jump Freq 3 d3-04 (0297) Jump Frequency Width Jump Bandwidth Eliminates problems with resonant vibration of the motor/ machine by avoiding continuous operation in predefined frequency ranges. The drive accelerates and decelerates the motor through the prohibited frequency ranges. Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03. Setting this parameter to 0.0 disables the function. Sets the dead-band width around each selected prohibited frequency reference point. Values Default: 0.0 Hz Min.: 0.0 Max.: 400.0 Default: 0.0 Hz Min.: 0.0 Max.: 400.0 Default: 0.0 Hz Min.: 0.0 Max.: 400.0 Default: 1.0 Hz Min.: 0.0 Max.: 20.0 Page – – – – Parameter List d3-01 (0294) Description B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 267 B.4 d: References u d4: Frequency Reference Hold and Up/Down 2 Function No. (Addr. Hex) d4-01 (0298) Name LCD Display Fref Hold Sel Frequency Reference Disabled Hold Function Selection 0: 1: Enabled d4-03 (02AA) Frequency Reference Bias Step (Up/Down 2) Up/Dn 2 Step Lvl d4-04 Frequency Reference (02AB) Bias Accel/Decel (Up/ Down 2) Up/Dn 2 Ramp Sel 0: Sel Acc/Dec Time 1: Acc/Dec Time 4 d4-05 Frequency Reference Up/Dn 2 Bias Sel (02AC) Bias Operation Mode 0: Hold Bias Value Selection (Up/Down 2) 1: Reset Bias Value d4-06 Frequency Reference (02AD) Bias (Up/Down 2) d4-07 Analog Frequency (02AE) Reference Fluctuation Limit (Up/Down 2) Description 0: Disabled. Drive starts from zero when the power is switched on. 1: Enabled. At power up, the drive starts the motor at the Hold frequency that was saved. Sets the bias added to the frequency reference when the Up 2 and Down 2 digital inputs are enabled (H1-oo = 75, 76). Values Page Default: 0 Range: 0, 1 – Default: 0.00 Hz Min.: 0.00 Max.: 99.99 – 0: Use selected accel/decel time. 1: Use accel/decel time 4 (C1-07 and C1-08). Default: 0 The functionality of setting 1 is only accessible Range: 0, 1 via MEMOBUS/Modbus communication. 0: Bias value is held if no input Up 2 or Down 2 is active. 1: When the Up 2 reference and Down 2 reference are both on Default: 0 Range: 0, 1 or both off, the applied bias becomes 0. The specified accel/ decel times are used for acceleration or deceleration. Note: – – Up/Dn 2 Bias Lvl The Up/Down 2 bias value is saved in d4-06 when the frequency Default: 0.0% reference is not input by the digital operator. Set as a percentage Min.: -99.9 of the maximum output frequency. Max.: 100.0 – Up/Dn 2 FluctLim Limits how much the frequency reference is allowed to change while an input terminal set for Up 2 or Down 2 is enabled. If the Default: 1.0% frequency reference changes for more than the set value, then Min.: 0.01 the bias value is held and the drive accelerates or decelerates to Max.: 100.0 the frequency reference. Set as a percentage of the maximum output frequency. – Up/Dn 2 UpperLim Sets the upper limit for the bias and the value that can be saved Default: 100.0% in d4-06. Set as a percentage of the maximum output frequency. Min.: 0.0 Max.: 100.0 – d4-08 (2AF) Frequency Reference Bias Upper Limit (Up/ Down 2) d4-09 (02B0) Frequency Reference Bias Lower Limit (Up/ Up/Dn 2 LowerLim Down 2) Sets the lower limit for the bias and the value that can be saved Default: 0.0% in d4-06. Set as a percentage of the maximum output frequency. Min.: -99.9 Max.: 0.0 – d4-10 (02B6) Up/Down Frequency Reference Limit Selection 0: The lower limit is determined by d2-02 or an analog input. 1: The lower limit is determined by d2-02. – 268 Up/Dn LowLim Sel 0: D2-02 or Analog 1: D2-02 Only Default: 0 Range: 0, 1 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.5 E: Motor Parameters B.5 E: Motor Parameters u E1: V/f Pattern No. (Addr. Hex) Name LCD Display Description Values Page This parameter must be set to the power supply voltage. E1-01 (0300) Input Voltage V/f Pattern Selection V/F Selection 0: 50 Hz 1: 60 Hz Saturation 2: 60 Hz Saturation 3: 72 Hz 4: 50 Hz VT1 5: 50 Hz VT2 6: 60 Hz VT1 7: 60 Hz VT2 8: 50 Hz HST1 9: 50 Hz HST2 A: 60 Hz HST1 B: 60 Hz HST2 C: 90 Hz D: 120 Hz E: 180 Hz F: Custom V/F 0: 50 Hz, Constant torque 1 1: 60 Hz, Constant torque 2 2: 60 Hz, Constant torque 3 (50 Hz base) 3: 72 Hz, Constant torque 4 (60 Hz base) 4: 50 Hz, Variable torque 1 5: 50 Hz, Variable torque 2 6: 60 Hz, Variable torque 3 7: 60 Hz, Variable torque 4 8: 50 Hz, High starting torque 1 9: 50 Hz, High starting torque 2 A: 60 Hz, High starting torque 3 B: 60 Hz, High starting torque 4 C: 90 Hz (60 Hz base) D: 120 Hz (60 Hz base) E: 180 Hz (60 Hz base) F: Custom V/f, E1-04 through E1-13 settings define the V/f pattern Default: F <2> Range: 0 to 9; A to FF – – Parameter List E1-03 (0302) Input Voltage Setting WARNING! Electrical Shock Hazard. Drive input voltage Default: 230 V (not motor voltage) must be set in E1-01 for the protective <1> features of the drive to function properly. Failure to do so Min.: 155 may result in equipment damage and/or death or personal Max.: 255 <1> injury. B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 269 B.5 E: Motor Parameters No. (Addr. Hex) E1-04 (0303) Name Maximum Output Frequency E1-05 (0304) Maximum Voltage E1-06 (0305) Base Frequency E1-07 (0306) Middle Output Frequency LCD Display Max Frequency Max Voltage Base Frequency Description Values Page These parameters are only applicable when E1-03 is set to F. To set linear V/f characteristics, set the same values for E1-07 and E1-09. In this case, the setting for E1-08 will be disregarded. Ensure that the four frequencies are set according to these rules: E1-09 ≤ E1-07 < E1-06 ≤ E1-11 ≤ E1-04 Default: 60.0 Hz Min.: 40.0 Max.: 400.0 – Output Voltage (V) E1-05 E1-12 E1-13 Middle Output Frequency Voltage Mid Frequency A Mid Voltage A E1-10 (0309) E1-11 (030A) <4> E1-12 (030B) <4> E1-13 (030C) <1> <2> <3> <4> Minimum Output Frequency Min.: 0.0 Max.: 255.0 – <1> – – Default: 15.0 V <1> E1-10 E1-09 E1-09 (0308) <1> Default: 60.0 Hz Min.: 0.0 Max.: E1-04 Default: 3.0 Hz Min.: 0.0 Max.: E1-04 E1-08 E1-08 (0307) Default: 230 V E1-07 E1-06 E1-11 E1-04 Frequency (Hz) Min Frequency Min.: 0.0 Max.: 255.0 <1> Default: 1.5 Hz (V/f) 0.5 Hz (OLV) Min.: 0.0 Max.: E1-04 – – Minimum Output Frequency Voltage Min Voltage Default: 9.0 V (V/f) 2.0 V (OLV) <1> Min.: 0.0 Max.: 255.0 <1> Middle Output Frequency 2 Mid Frequency B Default: 0.0 Hz Min.: 0.0 Max.: E1-04 – Middle Output Frequency Voltage 2 Mid Voltage B Default: 0.0 V Min.: 0.0 Max.: 255.0 <1> – – Default: 0.0 V Base Voltage <3> Base Voltage Min.: 0.0 Max.: 255.0 <1> – Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives. Parameter setting value is not reset to the default value when the drive is initialized. When Auto-Tuning is performed, E1-13 and E1-05 will be set to the same value. Parameter ignored when E1-11 (Motor 1 Mid Output Frequency 2) and E1-12 (Motor 1 Mid Output Frequency Voltage 2) are set to 0.0. u E2: Motor 1 Parameters No. (Addr. Hex) Name LCD Display Description Sets the motor nameplate full load current in amps. Automatically set during Auto-Tuning. E2-01 (30E) Motor Rated Current Motor Rated FLA E2-02 (030F) Motor Rated Slip Motor Rated Slip E2-03 (0310) Motor No-Load Current No-Load Current 270 Values Default: <1> Min.: 10% of drive rated current Max.: 200% of drive rated current <2> Sets the motor rated slip. Automatically set during Auto-Tuning. Default: <1> Min.: 0.00 Hz Max.: 20.00 Hz Sets the no-load current for the motor. Automatically set during Default: <1> Auto-Tuning. Min.: 0 A Max.: E2-01 <2> Page 157 – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.5 E: Motor Parameters No. (Addr. Hex) Name LCD Display E2-04 (0311) Number of Motor Poles Number of Poles E2-05 (0312) Motor Line-to-Line Resistance Term Resistance E2-06 (0313) Motor Leakage Inductance Leak Inductance E2-07 (0314) Motor Iron-Core Saturation Coefficient 1 Saturation Comp1 E2-08 (0315) Motor Iron-Core Saturation Coefficient 2 Saturation Comp2 E2-09 (0316) Motor Mechanical Loss Mechanical Loss E2-10 (0317) Motor Iron Loss for Torque Compensation E2-11 (0318) Motor Rated Power Motor Iron Loss Mtr Rated Power Description Values Page Sets the number of motor poles. Automatically set during Auto-Tuning. Default: 2 Min.: 2 Max.: 48 – Sets the phase-to-phase motor resistance. Automatically set during Auto-Tuning. Default: <1> Min.: 0.000 Ω Max.: 65.000 Ω – Sets the voltage drop due to motor leakage inductance as a percentage of motor rated voltage. Automatically set during Auto-Tuning. Default: <1> Min.: 0.0% Max.: 40.0% – Default: 0.50 Min.: E2-07 Max.: 0.50 – Default: 0.75 Min.: E2-07 Max.: 0.75 – OLV Sets the motor iron saturation coefficient at 50% of magnetic flux. Automatically set during Auto-Tuning. OLV Sets the motor iron saturation coefficient at 75% of magnetic flux. Automatically set during Auto-Tuning. OLV Default: 0.0% Sets the motor mechanical loss as a percentage of motor rated Min.: 0.0 Max.: 10.0 power (kW). V/f Sets the motor iron loss. Sets the motor rated power in kilowatts (1 HP = 0.746 kW). Automatically set during Auto-Tuning. – Default: <1> Min.: 0 W Max.: 65535 W – Default: <1> Min.: 0.00 kW Max.: 650.00 kW – Parameter List <1> Default setting is dependent on parameter o2-04, Drive Model Selection. <2> The number of decimal places in the parameter value depends on the drive model. This value has two decimal places (0.01 A) if the drive is set for a maximum applicable motor capacity up to and including 11 kW, and one decimal place (0.1 A) if the maximum applicable motor capacity is higher than 11 kW. B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 271 B.6 F: Options B.6 F: Options u F4: Analog Monitor Card (AO-A3) No. (Addr. Hex) F4-01 (0391) Name LCD Display Description Sets the monitor signal for output from terminal V1. Set this parameter to the last three digits of the desired Uo-oo monitor. Some U parameters are available only in certain control modes. Sets the gain for voltage output via terminal V1. Values Page Default: 102 Range: 000 to 999 – Default: 100.0% Min.: -999.9 Max.: 999.9 – Default: 103 Range: 000 to 999 – Default: 50.0% Min.: -999.9 Max.: 999.9 – Terminal V1 Monitor Selection AO Ch1 Select Terminal V1 Monitor Gain AO Ch1 Gain Terminal V2 Monitor Selection AO Ch2 Select Terminal V2 Monitor Gain AO Ch2 Gain Terminal V1 Monitor Bias AO Ch1 Bias Sets the amount of bias added to the voltage output via terminal Default: 0.0% V1. Min.: -999.9 Max.: 999.9 – Terminal V2 Monitor Bias AO Ch2 Bias Sets the amount of bias added to the voltage output via terminal Default: 0.0% V2. Min.: -999.9 Max.: 999.9 – F4-07 (0397) Terminal V1 Signal Level AO Opt Level Ch1 0: 0-10 VDC 1: -10 +10 VDC 0: 0 to 10 V 1: -10 to 10 V Default: 0 Range: 0, 1 – F4-08 (0398) Terminal V2 Signal Level AO Opt Level Ch2 0: 0-10 VDC 1: -10 +10 VDC 0: 0 to 10 V 1: -10 to 10 V Default: 0 Range: 0, 1 – F4-02 (0392) F4-03 (0393) F4-04 (0394) F4-05 (0395) F4-06 (0396) Sets the monitor signal for output from terminal V2. Set this parameter to the last three digits of the desired Uo-oo monitor. Some U parameters are available only in certain control modes. Sets the gain for voltage output via terminal V2. u F5: Digital Output Card (DO-A3) No. (Addr. Hex) F5-01 (399) F5-02 (39A) F5-03 (39B) F5-04 (39C) F5-05 (39D) F5-06 (39E) F5-07 (39F) F5-08 (3A0) Terminal P1-PC Output Selection Terminal P2-PC Output Selection Terminal P3-PC Output Selection Terminal P4-PC Output Selection Terminal P5-PC Output Selection Terminal P6-PC Output Selection Terminal M1-M2 Output Selection Terminal M3-M4 Output Selection F5-09 (3A1) DO-A3 Output Mode Selection 272 Name LCD Display DO Ch1 Select DO Ch2 Select DO Ch3 Select DO Ch4 Select DO Ch5 Select DO Ch6 Select DO Ch7 Select DO Ch8 Select DO Function Sel 0: 8ch Individual 1: Binary Output 2: 8ch Selected Description Values Page Sets the function for contact output terminals M1-M2, M3-M4, and photocoupler output terminals P1 through P6. Refer to H2: Multi-Function Digital Outputs on page 280 for setting selections. Default: 0 Range: 0 to 192 Default: 1 Range: 0 to 192 Default: 2 Range: 0 to 192 Default: 4 Range: 0 to 192 Default: 6 Range: 0 to 192 Default: 37 Range: 0 to 192 Default: F Range: 0 to 192 Default: F Range: 0 to 192 – 0: Output terminals are each assigned separate output functions. Default: 0 1: Binary code output. 2: Use output terminal functions selected by parameters F5-01 Range: 0 to 2 through F5-08. – – – – – – – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.6 F: Options u F6, F7: Communication Option Card Parameters F6-01 through F6-03 and F6-06 through F6-08 are used for DeviceNet and PROFIBUS-DP options. Other parameters in the F6 group are used for communication-protocol-specific settings. Name LCD Display F6-01 (03A2) Comm Bus Flt Sel Ramp to Stop Communications Error 0: 1: Coast to Stop Operation Selection 2: Fast-Stop 3: Alarm Only F6-02 (03A3) External Fault from Comm. Option Detection Selection EF0 Detection 0: Always Detected 1: Only During Run F6-03 (03A4) External Fault from Comm. Option Operation Selection EF0 Fault Action 0: Ramp to Stop 1: Coast to Stop 2: Fast-Stop 3: Alarm Only F6-04 (03A5) bUS Error Detection Time BUS Err Det Time F6-07 (03A8) Multi-Step Speed Fref PrioritySel Enable/Disable 0: Net/Com REF Selection when NefRef/ 1: MultiStep Speed ComRef is Selected F6-08 (036A) <1> Reset Communication Parameters Com Prm Init Sel 0: Init Com Prms 1: No Init Com Prms Description 0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02. 1: Coast to stop. 2: Fast Stop. Decelerate to stop using the deceleration time in C1-09. 3: Alarm only. 0: Always detected. 1: Detection during run only. Values Default: 1 Range: 0 to 3 – Default: 0 Range: 0, 1 – 0: Ramp to stop. Decelerate to stop using the deceleration time in C1-02. Default: 1 1: Coast to stop. 2: Fast Stop. Decelerate to stop using the deceleration time in Range: 0 to 3 C1-09. 3: Alarm only. Sets the delay time for error detection if a bus error occurs. 0: Multi-step reference disabled 1: Multi-step reference enabled Page – Default: 2.0 s Min.: 0.0 Max.: 5.0 – Default: 0 Range: 0, 1 – 0: Reset all communication-related parameters (F6-oo) when the drive is initialized using A1-03. Default: 0 1: Communication-related parameters (F6-oo) are not reset Range: 0, 1 when the drive is initialized using A1-03. Sets the node address. Default: 0 Min.: 0 Max.: 125 – F6-30 PROFIBUS-DP Node (03CB) Address PB Node Address F6-31 PROFIBUS-DP Clear (03CC) Mode Selection PB Clear Select 0: Reset to Zero 1: Hold Prev Value 0: Resets drive operation with a Clear mode command. 1: Maintains the previous operation state when Clear mode command is given. Default: 0 Range: 0, 1 – F6-32 PROFIBUS-DP Data (03CD) Format Selection PB Map Select 0: PPO Type 1: Conventional 0: PPO Type 1: Conventional Default: 0 Range: 0, 1 – Sets the node address. Default: 1 Min.: 0 Max.: 127 – Default: 3 Range: 0 to 8 – F6-45 (02FB) BACnet Node Address BAC Node Address F6-46 (02FC) BACnet Communication Speed BAC Baud Rate 0: 93.75 kbps 1: 2400 bps 2: 4800 bps 3: 9600 bps 4: 19.2 kbps 5: 38.4 kbps 6: 57.6 kbps 7: 76.8 kbps 8: 115.2 kbps F6-47 (02FC) Rx to Tx Wait Time Rx to Tx Wait T F6-48 (02FE) BACnet Device Objcet BAC Dev Obj Id 0 ID 0 BACnet device object ID F6-49 (02FF) BACnet Device Objcet BAC Dev Obj Id 1 ID 1 BACnet device object ID F6-50 (03C1) DeviceNet MAC Address Selects the drive MAC address. DN MAC Address 0: 93.75 kbps 1: 2400 bps 2: 4800 bps 3: 9600 bps 4: 19.2 kbps 5: 38.4 kbps 6: 57.6 kbps 7: 76.8 kbps 8: 115.2 kbps Rx to Tx Wait Time YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Default: 5 ms Min.: 5 Max.: 65 Default: 0 Min.: 0 Max.: FFFF Default: 0 Min.: 0 Max.: 3F Default: 64 Min.: 0 Max.: 64 – – – – – 273 Parameter List No. (Addr. Hex) B B.6 F: Options No. (Addr. Hex) Name LCD Display DN Baud Rate 0: 125 kbps 1: 250 kbps 2: 500 kbps 3: Set from Network 4: Auto Detect F6-51 (03C2) DeviceNet Communication Speed F6-52 (03C3) DeviceNet PCA Setting DN PCA Selection F6-53 (03C4) DeviceNet PPA Setting DN PPA Selection F6-54 (03C5) DeviceNet Idle Mode Fault Detection DN Idle Flt Det 0: Stop 1: Ignore DN BAUD RATE MEM 0: 125 kbps 1: 250 kbps 2: 500 kbps F6-55 (03C6) DeviceNet Baud Rate Monitor F6-56 (03D7) DeviceNet Speed Scaling DN Speed Scale F6-57 (03D8) DeviceNet Current Scaling DN Current Scale F6-58 (03D9) DeviceNet Torque Scaling DN Torque Scale F6-59 DeviceNet Power (03DA) Scaling DN Power Scale F6-60 DeviceNet Voltage (03DB) Scaling DN Voltage Scale F6-61 DeviceNet Time (03DC) Scaling DN Time Scale F6-62 DeviceNet Heartbeat (03DD) Interval DN Heart Beat F6-63 DeviceNet Network (03DE) MAC ID DN MAC ID MEM F6-64 to F6-71 Dynamic I/O Assembly – (03DF to Parameters 03C8) F7-01 IP Address 1 (03E5) IP Address 1 <2> F7-02 (03E6) IP Address 2 F7-03 (03E7) IP Address 3 F7-04 (03E8) IP Address 4 <2> <2> <2> F7-05 (03E9) 274 Subnet Mask 1 IP Address 2 IP Address 3 IP Address 4 Subnet Mask 1 Description 0: 125 kbps 1: 250 kbps 2: 500 kbps 3: Adjustable from network 4: Detect automatically Values Default: 4 Range: 0 to 4 Sets the format of the data set from the DeviceNet master to the Default: 21 drive. Min.: 0 Max.: 255 Sets the format of the data set from the drive to the DeviceNet Default: 71 master. Min.: 0 Max.: 255 0: Enabled Default: 0 1: Disabled, no fault detection Range: 0, 1 Verifies the baud rate running on the network. 0: 125 kbps 1: 250 kbps 2: 500 kbps Page – – – – Default: 0 Range: 0 to 2 – Sets the scaling factor for the speed monitor in DeviceNet. Default: 0 Min.: -15 Max.: 15 – Sets the scaling factor for the output current monitor in DeviceNet. Default: 0 Min.: -15 Max.: 15 – Sets the scaling factor for the torque monitor in DeviceNet. Default: 0 Min.: -15 Max.: 15 – Sets the scaling factor for the power monitor in DeviceNet. Default: 0 Min.: -15 Max.: 15 – Sets the scaling factor for the voltage monitor in DeviceNet. Default: 0 Min.: -15 Max.: 15 – Sets the scaling factor for the time monitor in DeviceNet. Default: 0 Min.: -15 Max.: 15 – Sets the heartbeat interval for DeviceNet communications. Default: 0 Min.: 0 Max.: 10 Saves and monitors settings 0 to 63 of F6-50 (DeviceNet MAC Default: 63 Address). Min.: 0 Max.: 63 Dynamic I/O Assembly Parameters – – – – Sets the most significant octet of network static IP address. Default: 192 Range: 0 to 255 – Sets the second most significant octet of network static IP address. Default: 168 Range: 0 to 255 – 1 Sets the third most significant octet of network static IP address. Default: Range: 0 to 255 – Sets the fourth most significant octet of network static IP address. Default: 20 Range: 0 to 255 – Sets the most significant octet of network static Subnet Mask. Default: 255 Range: 0 to 255 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.6 F: Options Name LCD Display Description Values Page Subnet Mask 2 Subnet Mask 2 Subnet Mask 3 Subnet Mask 4 Subnet Mask 4 Gateway Address 1 Gateway IP Add 1 Sets the most significant octet of network Gateway address. Gateway Address 2 Gateway IP Add 2 Gateway Address 3 Gateway IP Add 3 Gateway Address 4 Gateway IP Add 4 Default: 255 Range: 0 to 255 Default: 255 Range: 0 to 255 Default: 0 Range: 0 to 255 Default: 192 Range: 0 to 255 Default: 168 Range: 0 to 255 Default: 1 Range: 0 to 255 Default: 1 Range: 0 to 255 – Subnet Mask 3 Sets the second most significant octet of network static Subnet Mask. Sets the third most significant octet of network static Subnet Mask. Sets the fourth most significant octet of network static Subnet Mask. Default: 2 Range: 0 to 2 – – – – F7-13 (03F1) IP Add Mode Sel Address Mode at Startup 0: User Defined 1: BOOTP 2: DHCP Sets the second most significant octet of network Gateway address. Sets the third most significant octet of network Gateway address. Sets the fourth most significant octet of network Gateway address. Select the option address setting method 0: Static <3> 1: BOOTP 2: DHCP F7-14 (03F2) Duplex Select Duplex Mode Selection 0: Half Duplex 1: Auto Negotiate 2: Full Duplex Selects duplex mode setting. 0: Half duplex forced 1: Auto-negotiate duplex mode and communication speed 2: Full duplex forced Default: 1 Range: 0 to 2 – F7-15 (03F3) Communication Speed Selection Baud Rate 10: 10 Mbps 100: 100 Mbps Sets the communication speed 10: 10 Mbps 100: 100 Mbps Default: 10 Range: 10, 100 – F7-16 (03F4) Communication Loss Timeout CommLoss Tout Sets the timeout value for communication loss detection in Default: 0 tenths of a second. A value of 0 disables the connection timeout. Min.: 0 Example: An entered value of 100 represents 10.0 seconds. Max.: 300 – F7-17 (03F5) EtherNet/IP Speed Scaling Factor EN Speed Scale Sets the scaling factor for the speed monitor in EtherNet/IP Class ID 2AH Object. Default: 0 Min.: -15 Max.: 15 – F7-18 (03F6) EtherNet/IP Current Scaling Factor EN Current Scale Sets the scaling factor for the output current monitor in EtherNet/IP Class ID 2AH Object. Default: 0 Min.: -15 Max.: 15 – F7-19 (03F7) EtherNet/IP Torque Scaling Factor EN Torque Scale Sets the scaling factor for the torque monitor in EtherNet/IP Class ID 2AH Object. Default: 0 Min.: -15 Max.: 15 – F7-20 (03F8) EtherNet/IP Power Scaling Factor EN Power Scale Sets the scaling factor for the power monitor in EtherNet/IP Class ID 2AH Object. F7-21 (03F9) EtherNet/IP Voltage Scaling Factor EN Voltage Scale F7-22 EtherNet/IP Time (03FA) Scaling EN Time Scale F7-23 to F7-32 Dynamic Output (03FB to Assembly Parameters 0374) – F7-33 to F7-42 Dynamic Input (0375 to Assembly Parameters 037E) – Default: 0 Min.: -15 Max.: 15 Sets the scaling factor for the voltage monitor in EtherNet/IP Default: 0 Min.: -15 Class ID 2AH Object. Max.: 15 Sets the scaling factor for the time monitor in EtherNet/IP Class Default: 0 Min.: -15 ID 2AH Object. Max.: 15 Parameters used in Output Assembly 116. Each parameter contains a MEMOBUS/Modbus address. The value received for Output Assembly 116 will be written to this corresponding Default: 0 MEMOBUS/Modbus address. A MEMOBUS/Modbus address value of 0 means that the value received for Output Assembly 116 will not be written to any MEMOBUS/Modbus register. Parameters used in Input Assembly 166. Each parameter contains a MEMOBUS/Modbus address. The value sent for Input Assembly 166 will be read from this corresponding MEMOBUS/Modbus address. A MEMOBUS/Modbus address Default: 0 value of 0 means that the value sent for Input Assembly 166 is not defined by the user, therefore the option default register value will be returned. – – – – – – – – <1> Parameter setting value is not reset to the default value when the drive is initialized. <2> Cycle power for setting changes to take effect. <3> If F7-13 is set to 0, all IP addresses (F7-01 to F7-04) must be unique. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Parameter List No. (Addr. Hex) F7-06 (03EA) F7-07 (03EB) F7-08 (03EC) F7-09 (03ED) F7-10 (03EE) F7-11 (03EF) F7-12 (03E0) B 275 B.7 H Parameters: Multi-Function Terminals B.7 H Parameters: Multi-Function Terminals H parameters assign functions to the multi-function input and output terminals. u H1: Multi-Function Digital Inputs No. (Addr. Hex) Name H1-01 (0438) Multi-Function Digital Input Terminal S1 Function Selection Term S1 Func Sel H1-02 (0439) Multi-Function Digital Input Terminal S2 Function Selection Term S2 Func Sel Assigns a function to the multi-function digital inputs. Refer to pages 158 to 159 for descriptions of setting values. H1-03 (0400) Multi-Function Digital Input Terminal S3 Function Selection Term S3 Func Sel Note: Set unused terminals to F. Assigns a function to the multi-function digital inputs. Refer to pages 158 to 159 for descriptions of setting values. H1-04 (0401) Multi-Function Digital Input Terminal S4 Function Selection Term S4 Func Sel Note: Set unused terminals to F. Assigns a function to the multi-function digital inputs. Refer to pages 158 to 159 for descriptions of setting values. H1-05 (0402) Multi-Function Digital Input Terminal S5 Function Selection Term S5 Func Sel H1-06 (0403) Multi-Function Digital Input Terminal S6 Function Selection Term S6 Func Sel H1-07 (0404) Multi-Function Digital Input Terminal S7 Function Selection Term S7 Func Sel H1-08 (0405) Multi-Function Digital Input Terminal S8 Function Selection Term S8 Func Sel External Fault 1 Delay Time EF1 Delay Time Sets the amount of time delay applied to the EF1 fault. (20 ≤ H1-01 ≤ 2F) Default: 0.00 s Min.: 0.00 Max.: 300.00 – External Fault 2 Delay Time EF2 Delay Time Sets the amount of time delay applied to the EF2 fault. (20 ≤ H1-02 ≤ 2F) Default: 0.00 s Min.: 0.00 Max.: 300.00 – External Fault 3 Delay Time EF3 Delay Time Sets the amount of time delay applied to the EF3 fault. (20 ≤ H1-03 ≤ 2F) Default: 0.00 s Min.: 0.00 Max.: 300.00 – H1-24 (02DA) External Fault 4 Delay Time EF4 Delay Time Sets the amount of time delay applied to the EF4 fault. (20 ≤ H1-04 ≤ 2F) Default: 0.00 s Min.: 0.00 Max.: 300.00 – H1-25 (02DB) External Fault 5 Delay Time EF5 Delay Time Sets the amount of time delay applied to the EF5 fault. (20 ≤ H1-05 ≤ 2F) Default: 0.00 s Min.: 0.00 Max.: 300.00 – H1-26 (02DC) External Fault 6 Delay Time EF6 Delay Time Sets the amount of time delay applied to the EF6 fault. (20 ≤ H1-06 ≤ 2F) Default: 0.00 s Min.: 0.00 Max.: 300.00 – H1-27 (02DD) External Fault 7 Delay Time EF7 Delay Time Sets the amount of time delay applied to the EF7 fault. (20 ≤ H1-07 ≤ 2F) Default: 0.00 s Min.: 0.00 Max.: 300.00 – H1-21 (02D7) H1-22 (02D8) H1-23 (02D9) 276 LCD Display Description Assigns a function to the multi-function digital inputs. Refer to pages 158 to 159 for descriptions of setting values. Note: Note: Set unused terminals to F. Set unused terminals to F. Assigns a function to the multi-function digital inputs. Refer to pages 158 to 159 for descriptions of setting values. Note: Set unused terminals to F. Assigns a function to the multi-function digital inputs. Refer to pages 158 to 159 for descriptions of setting values. Note: Set unused terminals to F. Assigns a function to the multi-function digital inputs. Refer to pages 158 to 159 for descriptions of setting values. Note: Set unused terminals to F. Assigns a function to the multi-function digital inputs. Refer to pages 158 to 159 for descriptions of setting values. Note: Set unused terminals to F. Values Page Default: 40 (F) <1> Min.: 1 Max.: 9F 158 Default: F Min.: 1 Max.: 9F 158 Default: 26 Min.: 0 Max.: 9F 158 Default: 14 Min.: 0 Max.: 9F 158 Default: 8D (0) <1> Min.: 0 Max.: 9F 158 Default: 80 (3) <1> Min.: 0 Max.: 9F 158 Default: 81 (4) <1> Min.: 0 Max.: 9F Default: F (6) <1> Min.: 0 Max.: 9F 158 158 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.7 H Parameters: Multi-Function Terminals No. Name (Addr. Hex) H1-28 (02DE) External Fault 8 Delay Time LCD Display EF8 Delay Time Description Sets the amount of time delay applied to the EF8 fault. (20 ≤ H1-08 ≤ 2F) Values Default: 0.00 s Min.: 0.00 Max.: 300.00 Page – <1> Value in parenthesis is the default setting when a 3-Wire initialization is performed (A1-03 = 3330). H1 Multi-Function Digital Input Selections Function LCD Display Description Closed: Reverse rotation (only if the drive is set up for 3-Wire sequence) Terminals S1 and S2 are automatically set up for the Run command and Stop command. When input terminals are set to Multi-Step Speed References 1 through 3, switching combinations of those terminals will create a multi-step speed sequence using the frequency references set in d1-01 through d1-08. When input terminals are set to Multi-Step Speed References 1 through 3, switching combinations of those terminals will create a multi-step speed sequence using the frequency references set in d1-01 through d1-08. When input terminals are set to Multi-Step Speed References 1 through 3, switching combinations of those terminals will create a multi-step speed sequence using the frequency references set in d1-01 through d1-08. Closed: Jog frequency reference (d1-17) selected. Jog has priority over all other reference sources. Used to switch between accel/decel time 1 (set in C1-01, C1-02) and accel/decel time 2 (set in C1-03, C1-04). Page 0 3-Wire sequence 3-Wire Control 3 Multi-Step Speed Reference 1 Multi-Step Ref 1 4 Multi-Step Speed Reference 2 Multi-Step Ref 2 5 Multi-Step Speed Reference 3 Multi-Step Ref 3 6 Jog reference selection jog Freq Ref 7 Accel/decel time selection 1 Multi-Acc/Dec 1 8 Baseblock command (N.O.) Baseblock command (N.C.) Ext BaseBlk N.O. Closed: No drive output – Ext BaseBlk N.C. Open: No drive output – A Accel/decel ramp hold Acc/Dec RampHold Open: Accel/decel is not held Closed: The drive pauses during acceleration or deceleration and maintains the output frequency. – B Drive overheat alarm (oH2) Analog terminal input selection OH2 Alarm Signal Closed: Closes when an oH2 alarm occurs – Term A2 Enable – F Through mode Term Not Used 10 Up command Up Command 1 11 Down command Down Command 1 12 13 14 15 17 Forward Jog Reverse Jog Fault reset Fast Stop (N.O.) Fast Stop (N.C.) Forward Jog Reverse Jog Fault Reset Fast-Stop N.O. Fast-Stop N.C. 18 Timer function input Timer function 19 PID disable PID Disable 1A Accel/decel time selection 2 Multi-Acc/Dec 2 Open: Function assigned by H3-14 is disabled. Closed: Function assigned by H3-14 is enabled. Select this setting when using the terminal in a pass-through mode. The terminal does not trigger a drive function but can be used as digital input for the controller the drive is connected to. The drive accelerates when the Up command terminal closes, and decelerates when the Down command closes. When both terminals are closed or both are open, the drive holds the frequency reference. The Up and Down commands must always be used in conjunction with one another. The drive accelerates when the Up command terminal closes, and decelerates when the Down command closes. When both terminals are closed or both are open, the drive holds the frequency reference. The Up and Down commands must always be used in conjunction with one another. Closed: Runs forward at the Jog frequency d1-17. Closed: Runs reverse at the Jog frequency d1-17. Closed: Resets faults if the cause is cleared and the Run command is removed. Closed: Decelerates at the Fast Stop time set to C1-09. Open: Decelerates to stop at the Fast Stop time set to C1-09. Triggers the timer set up by parameters b4-01 and b4-02. Must be set in conjunction with the timer function output (H2-oo = 12). Open: PID control enabled Closed: PID control disabled Used in conjunction with an input terminal set for “Accel/decel time selection 1” (H1-oo = 7), and allows the drive to switch between accel/decel times 3 and 4. 9 C – – – – – – – – – – – – – – – – Parameter List H1-oo Setting B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 277 B.7 H Parameters: Multi-Function Terminals H1 Multi-Function Digital Input Selections H1-oo Setting Function LCD Display 1B Program lockout Program Lockout 1E Reference sample hold Ref Sample Hold 30 PID integral reset Ext Pump Fault 20: NO/Always Det, Ramp to Stop 21: NC/Always Det, Ramp to Stop 22: NO/During RUN, Ramp to Stop 23: N.C., During run, ramp to stop 24: NO/ Always Det, Coast to Stop 25: NC/Always Det, Coast to Stop 26: NO/During RUN, Coast to Stop 27: NC/During RUN, Coast to Stop 28: NO/Always Det, Fast-Stop 29: NC/Always Det, Fast-Stop 2A: NO/During RUN, Fast-Stop 2B: NC/During RUN, Fast- Stop 2C: NO/Always Det, Alarm Only 2D: NC/Always Det, Alarm Only 2E: NO/ During RUN, Alarm Only 2F: NC/During RUN, Alarm Only PID Intgrl Reset 31 PID integral hold PID Intgrl Hold 32 Multi-Step Speed Reference 4 34 PID soft starter cancel 35 PID input level selection PID Input Invert 40 Forward run command (2-Wire sequence) 20 to 2F External pump fault Open: Parameters cannot be edited (except for U1-01 if the reference source is assigned to the digital operator). Closed: Parameters can be edited and saved. Closed: Samples the analog frequency reference and operates the drive at that speed. 20: N.O., Always detected, ramp to stop 21: N.C., Always detected, ramp to stop 22: N.O., During run, ramp to stop 23: N.C., During run, ramp to stop 24: N.O., Always detected, coast to stop 25: N.C., Always detected, coast to stop 26: N.O., During run, coast to stop 27: N.C., During run, coast to stop 28: N.O., Always detected, Fast Stop 29: N.C., Always detected, Fast Stop 2A: N.O., During run, Fast Stop 2B: N.C., During run, Fast Stop 2C: N.O., Always detected, alarm only (continue running) 2D: N.C., Always detected, alarm only (continue running) 2E: N.O., During run, alarm only (continue running) 2F: N.C., During run, alarm only (continue running) Page – – – Closed: Resets the PID control integral value. Open: Performs integral operation. Closed: Maintains the current PID control integral value. – Multi-Step Ref 4 Used in combination with input terminals set to Multi-Step Speed Reference 1, 2, and 3. Use parameters d1-09 to d1-16 to set reference values. – PID SFS Cancel – FwdRun 2Wire Seq Open: PID soft starter is enabled. Closed: Disables the PID soft starter b5-17. Closed: Inverts the PID input signal. Open: Stop Closed: Forward run Reverse run command (2-Wire sequence) RevRun 2WireSeq Note: Cannot be set together with settings 42 or 43. Open: Stop Closed: Reverse run – Run command (2-Wire sequence 2) Run/Stp 2WireSeq Note: Cannot be set together with settings 42 or 43. Open: Stop Closed: Run – 43 FWD/REV command (2-Wire sequence 2) FWD/REV 2WireSeq 47 Node setup CanOpenNID Setup 51 Sequence Timer Disable SeqTimer Disable 41 42 278 Description Note: Cannot be set together with settings 40 or 41. Open: Forward Closed: Reverse Note: Determines motor direction, but does not issue a Run command. Cannot be set together with settings 40 or 41. Closed: Node setup for SI-S3 enabled. Closed: Drive ignores sequence timers and runs normally (based on b1-02/b1-16 source). – – – – – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.7 H Parameters: Multi-Function Terminals H1 Multi-Function Digital Input Selections Function LCD Display Description Page Closed: When the input changes from open to closed, the currently active sequence timer is disabled. Operation will resume with the next scheduled sequence timer. Cycling the Run command after the current sequence timer has been canceled will re-enable the sequence timer. – 52 Sequence Timer Cancel SeqTimer Cancel 60 DC Injection Braking command External Speed Search command 1 External Speed Search command 2 Field weakening KEB Ride-Thru 1 (N.C.) KEB Ride-Thru 1 (N.O.) Communications test mode DCInj Activate Closed: Triggers DC Injection Braking. – Speed Search 1 Closed: Activates Current Detection Speed Search from the maximum output frequency (E1-04). – Speed Search 2 Closed: Activates Current Detection Speed Search from the frequency reference. – Field Weak KEB Ridethru NC Closed: The drive performs Field Weakening control as set for d6-01 and d6-02. Open: KEB Ride-Thru 1 enabled. – – KEB Ridethru NO Closed: KEB Ride-Thru 1 enabled. – Comm Test Mode Tests the MEMOBUS/Modbus RS-422/RS-485 interface. Displays “PASS” if the test completes successfully. – 68 High Slip Braking (HSB) HighSlipBraking 6A Drive enable Drive Enable 73 Low City Press Low City Press 75 Up 2 command Up Command 2 76 Down 2 command Down Command 2 7A KEB Ride-Thru 2 (N.C.) KEB Ridethru2NC 7B KEB Ride-Thru 2 (N.O.) PID Bi-Direction Enable KEB Ridethru2NO 80 HAND Mode Hand Mode 81 HAND Mode 2 Hand Mode 2 88 Volute-Thermostat Normally Open Volute-TStat NO Volute-Thermostat Normally Closed Volute-TStat NC 8C Disable Pre-Charge Disable Pre-Chrg 8D Multi Setpoint 1 Multi Setpoint 1 8E Multi Setpoint 2 Multi Setpoint 2 61 62 63 65 66 67 7F 89 PID BiDir Enable V/f Closed: Activates High Slip Braking to stop the drive during a Run command. Open: Drive disabled. If this input is opened during run, the drive will stop as specified by b1-03. Closed: Ready for operation. Indicates that sufficient or insufficient pressure is present on the inlet to the pump. Used mainly for pressure booster situations. Note: Parameter P4-21 determines if this input is normally open or normally closed. Controls the bias added to the frequency reference by the Up/Down 2 function. The Up 2 and Down 2 commands must always be used in conjunction with one another. Controls the bias added to the frequency reference by the Up/Down 2 function. The Up 2 and Down 2 commands must always be used in conjunction with one another. Open: KEB Ride-Thru 2 enabled. Drive disregards L2-29 and performs Single Drive KEB Ride-Thru 2. Closed: KEB Ride-Thru 2 enabled. Drive disregards L2-29 and performs Single Drive KEB Ride-Thru 2. PID Bi-Direction Enable Closed: HAND Mode operation. Frequency reference determined by P5-01 and P5-02. Open: Stop Mode when no Run command. Closed: HAND Mode operation. Frequency reference determined by P5-05. Open: Stop Mode when no Run command. Function active when the drive is running. Closed: Drive will trip on “VLTS - Volute-TStat Flt” Open: Thermostat fault not active – – – – – – – – – – Note: Setting H1-oo = 88 and 89 simultaneously will trigger a “VLTS Volute-TStat Flt”. Function active when the drive is running. Closed: Thermostat fault not active Open: Drive will trip on “VLTS - Volute-TStat Flt” Note: Setting H1-oo = 88 and 89 simultaneously will trigger a “VLTS Volute-TStat Flt”. Closed: Pre-Charge disabled. Open: Frequency reference, Q1-01, or Q1-03 is PID Setpoint. Closed: Q1-02 or Q1-04 is PID Setpoint. Open: Frequency reference, Q1-01, or Q1-02 is PID Setpoint. Closed: Q1-03 or Q1-04 is PID Setpoint. – – – Parameter List H1-oo Setting B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 279 B.7 H Parameters: Multi-Function Terminals H1 Multi-Function Digital Input Selections H1-oo Setting Function LCD Display 8F Low Water Level Low Water 90 High Water Level High Water 92 Reset Accumulated Volume Reset Accum Description Page Function active in AUTO Mode during normal operation, also used with PreCharge function. Function logic depends on P1-30, Low Water Digital Input Configuration. P1-30 = 0 (Normally open) Closed: Low water level fault Open: Reservoir/Tank is filled to normal level P1-30 = 1 (Normally closed) Closed: Reservoir/Tank is filled to normal level Open: Low water level fault Pre-Charge function: Function uses the low water level input as “Tank/Reservoir” feedback to indicate that the water level has been reached. Function active when the drive is running. Function logic depends on P1-31, High Water Digital Input Configuration. P1-31 = 0 (Normally open) Closed: High water level fault Open: Reservoir/Tank is filled to normal level P1-31 = 1 (Normally closed) Closed: Reservoir/Tank is filled to normal level Open: High water level fault Closed: Accumulated volume is reset to 0 and held at 0 if digital input remains closed. Closed: Prevents the drive from running when active for the time set in P4-26. Must be inactive for the time set in P4-27 to allow the drive to run again. – – – 95 Remove Drive Disable Remote Drv Disbl A8 Secondary PI Disable (N.O.) PI2 Disable N.O. Closed: Disables the secondary PI controller. Output behavior depends on the setting of S3-12. – A9 Secondary PI Disable (N.C.) PI2 Disable N.C. Closed: Enables the secondary PI controller. Output behavior depends on the setting of S3-12 when open. – AA Secondary PI Inverse Operation PI2 Invert Closed: Changes the sign of the secondary PI controller input (reverse acting PI control). – AB Secondary PI Integral Reset PI2 Intgrl Reset Closed: Resets the secondary PI controller integral value. – AC Secondary PI Integral Hold PI2 Intgrl Hold Closed: Locks the value of the secondary PI controller integral value. – Select PI2 Parms Closed: Uses the secondary PI controller Proportional and Integral adjustments (S3-06 and S3-07) instead of the primary PI controller Proportional and Integral adjustments (b5-02 and b5-03). Only valid when S3-01 = 0 (secondary PI controller disabled). – AD Select Secondary PI Parameters Note: Parameter P4-25 determines if this input is normally open or normally closed. – Note: AF B0 Emergency Override Forward Run Emergency Override Reverse Run EmergOverrideFWD This multi-function input has no effect on the secondary PI controller. It is only used for the primary PI controller (b5-oo). Closed: Run the drive forward using the speed set in S6-02. – EmergOverrideREV Closed: Run the drive in reverse using the speed set in S6-02. – u H2: Multi-Function Digital Outputs No. (Addr. Hex) H2-01 (040B) H2-02 (040C) H2-03 (040D) 280 Name Terminal M1-M2 function selection (relay) Terminal M3-M4 function selection (relay) Terminal MD-ME-MF Function Selection LCD Display Values Page Default: 37 Range: 0 to 192 159 M3/M4 Func Sel Default: F Range: 0 to 192 159 MD/ME/MF Func Sel Default: E Range: 0 to 192 159 M1-M2 Func Sel Description Refer to H2 Multi-Function Digital Output Settings on pages 159 to 160 for descriptions of setting values. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.7 H Parameters: Multi-Function Terminals No. (Addr. Hex) H2-06 (0437) Name LCD Display Watt Hour Output Unit Pwr Mon Unit Sel Selection Description Outputs a 200 ms pulse signal when the watt-hour counter increases by the units selected. 0: 0.1 kWh units 1: 1 kWh units 2: 10 kWh units 3: 100 kWh units 4: 1000 kWh units Values Default: 0 Range: 0 to 4 Page – H2 Multi-Function Digital Output Settings LCD Display During RUN 1 Description Page Closed: A Run command is active or voltage is output. Open: Output frequency is above the minimum output frequency set in E1-09. Closed: Output frequency is below the minimum output frequency set in E1-09. Closed: Output frequency equals the speed reference (plus or minus the hysteresis set to L4-02). Closed: Output frequency and speed reference equal L4-01 (plus or minus the hysteresis set to L4-02). Closed: Output frequency is less than or equal to the value in L4-01 with hysteresis determined by L4-02. – 1 Zero speed Zero Speed 2 Speed agree 1 Fref/Fout Agree1 3 User-set speed agree 1 Fref/Set Agree 1 4 Frequency detection 1 Freq Detect 1 5 Frequency detection 2 Freq Detect 2 Closed: Output frequency is greater than or equal to the value in L4-01 with hysteresis determined by L4-02. – 6 7 Drive ready DC bus undervoltage During baseblock (N.O.) Drive Ready DC Bus Undervolt Closed: Power up is complete and the drive is ready to accept a Run command. Closed: DC bus voltage is below the Uv trip level set in L2-05. Closed: Drive has entered the baseblock state (no output voltage). – – 8 BaseBlk 1 – – – 9 Frequency reference source Ref Source Open: External Reference 1 or 2 supplies the frequency reference (set in b1-01 or b1-15). Closed: Digital operator supplies the frequency reference. – A Run command source Run Cmd Source Open: External Reference 1 or 2 supplies the Run command (set in b1-02 or b1-16). Closed: Digital operator supplies the Run command. – B Torque detection 1 (N.O.) Trq Det 1 N.O. Closed: An overtorque or undertorque situation has been detected. – C Frequency reference loss Loss of Ref Closed: Analog frequency reference has been lost. Frequency reference loss is detected when the frequency reference drops below 10% of the reference within 400 ms. – D E F Braking resistor fault Fault Through mode DB Overheat Fault Not Used 10 Minor fault Minor Fault 11 Reset Cmd Active 12 13 14 Fault reset command active Timer output Speed agree 2 User-set speed agree 2 Timer Output Fref/Fout Agree2 Fref/Set Agree 2 15 Frequency detection 3 Freq Detect 3 16 Frequency detection 4 Freq Detect 4 17 Torque detection 1 (N.C.) Torque detection 2 (N.O.) Torque detection 2 (N.C.) During reverse Trq Det 1 N.C. Closed: Braking resistor or transistor is overheated or faulted out. Closed: Fault occurred. Set this value when using the terminal in the pass-through mode. Closed: An alarm has been triggered, or the IGBTs have reached 90% of their expected life span. Closed: A command has been entered to clear a fault via the input terminals or from the serial network. Closed: Timer output. Closed: When drive output frequency equals the frequency reference ±L4-04. Closed: When the drive output frequency is equal to the value in L4-03 ±L4-04. Closed: When the drive output frequency is less than or equal to the value in L4-03 ±L4-04. Closed: When the output frequency is greater than or equal to the value in L4-03 ±L4-04. Open: Overtorque or undertorque has been detected. Trq Det 2 N.O. Closed: Overtorque or undertorque has been detected. Trq Det 2 N.C. Open: Overtorque or undertorque has been detected. – Reverse Dir Closed: Drive is running in the reverse direction. – 18 19 1A YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide – – – – – – – – – – – 281 Parameter List H2-oo Function Setting 0 During run B B.7 H Parameters: Multi-Function Terminals H2 Multi-Function Digital Output Settings H2-oo Setting 1B 1E 1F 20 22 Function During baseblock (N.C.) Restart enabled Motor overload alarm (oL1) Drive overheat prealarm (oH) Mechanical weakening detection LCD Display Description Page BaseBlk 2 Open: Drive has entered the baseblock state (no output voltage). – Dur Flt Restart – OH Prealarm Closed: An automatic restart is performed Closed: oL1 is at 90% of its trip point or greater. An oH3 situation also triggers this alarm. Closed: Heatsink temperature exceeds the parameter L8-02 value. – MechFatigue(OL5) Closed: Mechanical weakening detected. – Closed: Cooling fan, electrolytic capacitors, IGBTs, or the soft charge bypass relay may require maintenance. – Overload (OL1) – 2F Maintenance period Maintenance 30 During torque limit Torque Limit 37 During frequency output During RUN 2 38 Drive enabled Drive Enable 39 Watt hour pulse output Watt-hour Pulse 3C LOCAL/REMOTE status Local Open: REMOTE Closed: LOCAL – 3D 3E 3F 4A During speed search PID feedback low PID feedback high During KEB Ride-Thru During SpdSrch PID Feedback Low PID FeedbackHigh During KEB – – – – 4C During fast stop During Fast Stop Closed: Speed Search is being executed. Closed: PID feedback level is too low. Closed: The PID feedback level is too high. Closed: KEB Ride-Thru is being performed. Closed: A Fast Stop command has been entered from the operator or input terminals. 4D oH Pre-alarm time limit OH Pre-Alarm Braking transistor fault Brk Trans Fault (rr) Closed: oH pre-alarm time limit has passed. Closed: The built-in dynamic braking transistor failed. – 4F Braking resistor overheat (oH) BrkResistOvHeat Closed: The dynamic braking resistor has overheated. – 50 51 52 53 54 58 Waiting to Run Sequence timer 1 Sequence timer 2 Sequence timer 3 Sequence timer 4 Underload detection Internal cooling fan alarm Secondary PI Feedback Low Secondary PI Feedback High Waiting for Run SeqTimer Disable SeqTimer Cancel Sequence timer 3 Sequence Timer 4 UL6 – – – – – – Fan Alrm Det Closed: b1-11 Timer is active. Closed: Sequence timer 1 is active. Closed: Sequence timer 2 is active. Closed: Sequence timer 3 is active. Closed: Sequence timer 4 is active. Closed: Underload is detected. Closed: Internal cooling fan alarm – PI2 Feedback Low Closed: PI2 feedback level is too low. – PI2 FeedbackHigh Closed: The PI2 feedback level is too high. – Contactor control for a second pump. The function is active in contactor multiplex mode only (P1-01 = 1). Contactor control for a third pump. The function is active in contactor multiplex mode only (P1-01 = 1) and when P3-01 is set to a value greater than 1. Contactor control for a fourth pump. The function is active in contactor multiplex mode only (P1-01 = 1) and when P3-01 is set to a value greater than 2. Contactor control for a fifth pump. The function is active in contactor multiplex mode only (P1-01 = 1) and when P3-01 is set to a value greater than 3. – 4E 60 71 72 282 80 Pump 2 Control Pump 2 Control 81 Pump 3 Control Pump 3 Control 82 Pump 4 Control Pump 4 Control 83 Pump 5 Control Pump 5 Control OLV Closed: The torque limit has been reached. Open: Either the drive has stopped or baseblock, DC Injection Braking, or Initial Excitation is being performed. Closed: Drive is running the motor (not in a baseblock state and DC Injection is not being performed). Closed: Multi-function input set for “Drive enable” is closed (H1-oo = 6A) Output units are determined by H2-06. Outputs a pulse every 200 ms to indicate the kWh count. – – – – – – – – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.7 H Parameters: Multi-Function Terminals H2 Multi-Function Digital Output Settings Function LCD Display Description Contactor control for a sixth pump. The function is active in contactor multiplex mode only (P1-01 = 1) and when P3-01 is set to a value greater than 4. Closed: Drive output speed is being limited due to the output current limit or the single phase foldback regulator. Closed: Energizes for the time set in P4-31 each time the drive is supposed to start. Internal Fan On Closed when any of the following faults are active: • Low feedback • High feedback • Low water • High water • NMS-Setpoint not met • POC-Pump over cycle • THMS-Thermostat input • External pump fault Closed: The analog output associated with PID feedback has risen above 21 mA or fallen below 3 mA or a Transducer Loss alarm or fault is active. Page 84 Pump 6 Control Pump 6 Control 89 Output 1 Limit Output I Lim 8B 8F Lube Pump Internal Fan On Lube Pump Internal Fan On 91 Pump Fault Pump Fault 92 Transducer Loss Transducer Loss 93 94 95 Setptoint Not Met SetPoint Not Met Loss of Prime Loss of Prime Volute Thermostat Fault Volute-TStat Flt 96 High Feedback High Feedback 97 Low Feedback Low Feedback Closed: During a “Low Feedback” condition as defined by P1-08 and P1-12 OR Closed: During a “Low FB/Water” fault OR Closed: During a “Low Feedback” alarm – 98 Low Flow Low Flow Closed: During the “Low Flow Fault” condition OR Closed: During a Low Flow condition set by P6-06 to P6-08, including a “Low Flow” alarm – 99 Accum Level Accum Level Closed: Accumulated level has exceeded the P6-11 to P6-14 settings OR Closed: During the “Accum Level” fault – 9A High Flow High Flow Closed: During the “High Flow Fault” condition OR Closed: During a “High Flow” condition set by P6-17 and P6-18, including a “High Flow” alarm – 9B Low Water Level Low Water Level 9C Low Suction Low Suction 9D High Suction High Suction A2 Sleep Active Sleep Active A3 Start Delay Start Delay A4 Pre-Charge Pre-Chg Active A5 Anti-Jam Active Anti-Jam Active A9 Thrust Mode Thrust Mode AA Utility Start Delay Utility Delay 100 to 1AA Function 0 to AA with inverse output – Closed: During an “NMS-Setpoint Not Met” condition. Closed: During an “LOP-Loss of Prime” condition. Closed: Volute-Thermostat digital input is active. Closed: During a “High Feedback” condition as defined by P1-11 and P1-12 OR Closed: During a “High FB/Water” fault OR Closed: During a “High Feedback” alarm Closed: The water level has dropped below the Low Detection Level set in Q4-09 for longer than the Low Level Detection Delay Time set in Q4-09 or if there is a LOWWL – Low Water Level Fault. Closed: The suction pressure has dropped below the Low Suction Pressure Detection Level set in Q5-09 for longer than the Low Suction Pressure Delay Time set in Q5-10 or if there is a LOSUC – Low Suction Pressure Fault. Closed: The suction pressure has risen above the High Suction Pressure Detection Level set in Q5-12 for longer than the High Suction Pressure Delay Time set in Q5-13 or if there is a HISUC – High Suction Pressure Fault. Closed: The drive is not running due to the Sleep function (does not include Sleep Boost). Closed: Feedback has risen above the start level (or fallen below for Inverse PID) and the start timer is timing. Closed: Drive is in Pre-Charge mode. Closed: The anti-jam function is active (configured by P7-oo). Closed: The Thrust Bearing feature is active (output frequency is between 0 and the value of P4-12). Closed: The drive is stopped and waiting for the utility delay timer set in P4-17 to expire. Inverts the output switching of the multi-function output functions. Set the last two digits of 1oo to reverse the output signal of that specific function. – – – – – – – – – – – – – – – – – – – Parameter List H2-oo Setting B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 283 B.7 H Parameters: Multi-Function Terminals u H3: Multi-Function Analog Inputs No. (Addr. Hex) H3-01 (0410) H3-02 (0434) H3-03 (0411) Name Terminal A1 Signal Level Selection LCD Display Term A1 Level 0: 0-10V, (LowLim=0) 1: 0-10V, (BipolRef) 2: 4-20 mA 3: 0-20 mA Description 0: 0 to 10 V 1: -10 to 10 V 2: 4 to 20 mA 3: 0 to 20 mA Use Jumper S1 to set input terminal A1 for a current or voltage input signal. Sets the function of terminal A1. Values Page Default: 0 Range: 0 to 3 160 Default: 0 Range: 0 to 32 160 Note: Terminal A1 Function Selection Term A1 FuncSel Terminal A1 Gain Setting Terminal A1 Gain Sets the level of the input value selected in H3-02 when 10 V is Default: 100.0% input at terminal A1. Min.: -999.9 Max.: 999.9 160 Terminal A1 Bias Setting Terminal A1 Bias Sets the level of the input value selected in H3-02 when 0 V is Default: 0.0% input at terminal A1. Min.: -999.9 Max.: 999.9 160 Terminal A3 Signal Level Selection Term A3 Level 0: 0-10V, (LowLim=0) 1: 0-10V, (BipolRef) 2: 4-20 mA 3: 0-20 mA 0: 0 to 10 V 1: -10 to 10 V 2: 4 to 20 mA 3: 0 to 20 mA Terminal A3 Function Selection Term A3 FuncSel Sets the function of terminal A3. Terminal A3 Gain Setting Terminal A3 Gain Sets the level of the input value selected in H3-06 when 10 V is Default: 100.0% input at terminal A3. Min.: -999.9 Max.: 999.9 162 Terminal A3 Bias Setting Terminal A3 Bias Sets the level of the input value selected in H3-06 when 0 V is Default: 0.0% input at terminal A3. Min.: -999.9 Max.: 999.9 162 Terminal A2 Signal Level Selection Term A2 Level 0: 0-10V, (LowLim=0) 1: 0-10V, (BipolRef) 2: 4-20 mA 3: 0-20 mA 0: 0 to 10 V 1: -10 to 10 V 2: 4 to 20 mA 3: 0 to 20 mA Terminal A2 Function Selection Term A2 FuncSel Terminal A2 Gain Setting Terminal A2 Gain Terminal A2 Bias Setting Terminal A2 Bias H3-13 (041B) Analog Input Filter Time Constant A1/A2 Filter T H3-14 (041C) A1/A2 Sel 1: A1 Available 2: A2 Available Analog Input Terminal 3: A1/A2 Available Enable Selection 4: A3 Available 5: A1/A3 Available 6: A2/A3 Available 7: All Available H3-16 (02F0) Terminal A1 Offset H3-04 (0412) H3-05 (0413) H3-06 (0414) H3-07 (0415) H3-08 (0416) H3-09 (0417) H3-10 (0418) H3-11 (0419) H3-12 (041A) 284 Term A1 Offset Note: Default: 0 Range: 0 to 3 161 Default: 20 Range: 0 to 32 161 Use Jumper S1 to set input terminal A3 for a current or voltage input signal. Default: 2 Range: 0 to 3 162 Sets the function of terminal A2. Default: B Range: 0 to 32 162 Sets the level of the input value selected in H3-10 when 10 V (20 mA) is input at terminal A2. Default: 100.0% Min.: -999.9 Max.: 999.9 162 Note: Use Jumper S1 to set input terminal A2 for a current or voltage input signal. Sets the level of the input value selected in H3-10 when 0 V (0 Default: 0.0% or 4 mA) is input at terminal A2. Min.: -999.9 Max.: 999.9 Sets a primary delay filter time constant for terminals A1, A2, Default: 0.03 s and A3. Used for noise filtering. Min.: 0.00 Max.: 2.00 Determines which analog input terminals will be enabled when a digital input programmed for “Analog input enable” (H1-oo = C) is activated. 1: Terminal A1 only Default: 7 2: Terminal A2 only Range: 1 to 7 3: Terminals A1 and A2 only 4: Terminal A3 only 5: Terminals A1 and A3 6: Terminals A2 and A3 7: All terminals enabled Default: 0 Adds an offset when the analog signal to terminal A1 is at 0 V. Min.: -500 Max.: 500 162 – – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.7 H Parameters: Multi-Function Terminals No. (Addr. Hex) Name LCD Display H3-17 (02F1) Terminal A2 Offset Term A2 Offset H3-18 (02F2) Terminal A3 Offset Term A3 Offset Description Values Default: 0 Adds an offset when the analog signal to terminal A2 is at 0 V. Min.: -500 Max.: 500 Default: 0 Adds an offset when the analog signal to terminal A3 is at 0 V. Min.: -500 Max.: 500 Page – – H3 Multi-Function Analog Input Settings LCD Display Page – – – 1 Frequency gain Freq Ref Gain 2 Auxiliary frequency reference 1 Auxiliary frequency reference 2 Aux Reference1 10 V = E1-04 (maximum output frequency) 0 to 10 V signal allows a setting of 0 to 100%. -10 to 0 V signal allows a setting of -100 to 0%. 10 V = E1-04 (maximum output frequency) Aux Reference2 10 V = E1-04 (maximum output frequency) 3 Freq Ref Bias Description 4 Output voltage bias Voltage Bias 5 Accel/decel time gain DC Injection Braking current Overtorque/ undertorque detection level Acc/Dec Change 6 7 DC Brake Current Torque Det Level V/f 10 V = E1-05 (motor rated voltage) 10 V = 100% 10 V = Drive rated current 10 V = Drive rated current (V/f) – – – – – 8 Stall Prevention level during run 9 Output frequency lower Ref Lower Limit limit level 10 V = E1-04 (maximum output frequency) – B C D PID feedback PID setpoint Frequency bias PID Feedback1 PID Set Point Freq Ref Bias 2 – – – E Motor Temperature (PTC Input) 10 V = 100% 10 V = 100% 10 V = E1-04 (maximum output frequency) 10 V = 100% E Motor PTC F Through mode Not Used 10 Forward torque limit Fwd Torque Limit 11 Reverse torque limit Rev Torque Limit 12 Regenerative torque limit Regen Torq Limit 15 General torque limit Torque Limit 16 Differential PID feedback Through mode HAND Frequency Reference PID Feedback 2 10 V = 100% – Not Used Set this value when using the terminal in the pass-through mode. – Hand Freq. Ref. Full scale: Max. frequency (E1-04) – 1F 20 Stall Prev Level 21 Geothermal Temperature Geothermal Temp 22 Flow Meter Flow Meter V/f 10 V = Drive rated current Note: A 12 kΩ resistor must be connected between terminals A1, A2, or A3 and V+ for PTC functionality. Select this setting when using the terminal in a pass-through mode. The terminal does not trigger a drive function but can be used as digital input for the controller the drive is connected to. OLV 10 V = Motor rated torque OLV 10 V = Motor rated torque OLV 10 V = Motor rated torque OLV 10 V = Motor rated torque Full scale: Q2-02 = 10 V (or 20 mA), Q2-01 = 0 V (or 4 mA) This input is internally limited to -110.0 °F to +320.0 °F after gain and bias. Full scale: P6-01 – – – – – – – – – Parameter List H3-oo Function Setting 0 Frequency bias B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 285 B.7 H Parameters: Multi-Function Terminals H3 Multi-Function Analog Input Settings H3-oo Setting Function LCD Display Description 23 Water Level or Suction WaterLvl/Suction Input When Water Level Control is enabled (Q4-01 = 1): 0 V or 4 mA = 0 (ft) 10 V or 20 mA = Q4-02 (PSI) * 2.308 ft/PSI OR When Suction Pressure Control is enabled (Q5-01 = 1) <1> 0 V or 4 mA = 9 (PSI) 10 V or 20 mA = Q5-02 (PSI) OR When Vacuum Control is enabled (Q5-01 = 2) <2> 0 V or 4 mA = 0 (”Hg) 10 V or 20 mA = Q5-02 (”Hg) 25 26 Secondary PI Setpoint PI2 Setpoint Secondary PI Feedback PI2 Feedback 10 V = S3-02 (maximum output frequency) 10 V = S3-02 (maximum output frequency) Page – – – <1> When Pressure Control is enabled (Q5-01 = 1), the action of the analog input is normal. A higher voltage or current on the input causes a higher pressure to be read in the drive. <2> When Vacuum Control is enabled (Q5-01 = 2), the action of the analog input is reversed. A higher voltage or current on the input causes a lower pressure (or higher level of vacuum) to be read in the drive. u H4: Analog Outputs No. (Addr. Hex) Name LCD Display Description Selects the data to be output through multi-function analog output terminal FM. Set the desired monitor parameter to the digits available in Uo-oo. For example, enter “103” for U1-03. Sets the signal level at terminal FM that is equal to 100% of the selected monitor value. Values Page H4-01 (041D) Multi-Function Analog Output Terminal FM Term FM FuncSel Monitor Selection H4-02 (041E) Multi-Function Analog Terminal FM Gain Output Terminal FM Gain H4-03 (041F) Multi-Function Analog Terminal FM Bias Output Terminal FM Bias H4-04 (0420) Multi-Function Analog Output Terminal AM Terminal AM Sel Monitor Selection H4-05 (0421) Multi-Function Analog Terminal AM Gain Output Terminal AM Gain H4-06 (0422) Multi-Function Analog Terminal AM Bias Output Terminal AM Bias Sets the signal level at terminal AM that is equal to 0% of the Default: 0.0% selected monitor value. Min.: -999.9 Max.: 999.9 163 Multi-Function Analog Level Select1 0: 0-10 VDC Output Terminal FM Signal Level Selection 1: -10 +10 VDC 2: 4-20 mA Multi-Function Analog AO Level Select2 0: 0-10 VDC Output Terminal AM Signal Level Selection 1: -10 +10 VDC 2: 4-20 mA 0: 0 to 10 V 1: -10 to 10 V 2: 4 to 20mA Default: 0 Range: 0 to 2 164 0: 0 to 10 V 1: -10 to 10 V 2: 4 to 20 mA Default: 0 Range: 0 to 2 164 H4-07 (0423) H4-08 (0424) 286 Sets the signal level at terminal FM that is equal to 0% of the selected monitor value. Selects the data to be output through multi-function analog output terminal AM. Set the desired monitor parameter to the digits available in Uo-oo. For example, enter “103” for U1-03. Sets the signal level at terminal AM that is equal to 100% of the selected monitor value. Default: 102 Range: 000 to 999 162 Default: 100.0% Min.: -999.9 Max.: 999.9 163 Default: 0.0% Min.: -999.9 Max.: 999.9 163 Default: 103 Range: 000 to 999 162 Default: 50.0% Min.: -999.9 Max.: 999.9 163 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.7 H Parameters: Multi-Function Terminals u H5: MEMOBUS/Modbus Serial Communication No. (Addr. Hex) H5-01 (0425) <1> Name Drive Node Address LCD Display Serial Comm Adr Serial Baud Rate 0: 1200 bps 1: 2400 bps 2: 4800 bps 3: 9600 bps 4: 19.2 kbps 5: 38.4 kbps 6: 57.6 kbps 7: 76.8 kbps 8: 115.2 kbps Serial Com Sel 0: No parity 1: Even parity 2: Odd parity Serial Fault Sel 0: Ramp to Stop 1: Coast to Stop 2: Fast-Stop 3: Alarm Only H5-02 (0426) Communication Speed Selection H5-03 (0427) Communication Parity Selection H5-04 (0428) Stopping Method after Communication Error (CE) H5-05 (0429) Communication Fault Detection Selection Serial Flt Dtct 0: Disabled 1: Enabled H5-06 (042A) Drive Transmit Wait Time Transmit WaitTIM H5-07 (042B) RTS Control Selection H5-09 (0435) Description Values Selects drive station node number (address) for MEMOBUS/ Default: 1F Modbus terminals R+, R-, S+, S-. Cycle power for the setting (Hex) to take effect. Min.: 0 Max.: FF <2> 0: 1200 bps 1: 2400 bps 2: 4800 bps 3: 9600 bps Default: 3 4: 19200 bps Range: 0 to 8 5: 38400 bps 6: 57600 bps 7: 76800 bps 8: 115200 bps Cycle power for the setting to take effect. 0: No parity Default: 0 1: Even parity Range: 0 to 2 2: Odd parity Cycle power for the setting to take effect. 0: Ramp to stop 1: Coast to stop Default: 3 2: Fast Stop Range: 0 to 3 3: Alarm only 0: Disabled Default: 1 1: Enabled. If communication is lost for more than two seconds, Range: 0, 1 a CE fault will occur. Page – – – – – Set the wait time between receiving and sending data. Default: 5 ms Min.: 5 Max.: 65 – RTS Control Sel 0: Disabled 1: Enabled 0: Disabled. RTS is always on. 1: Enabled. RTS turns on only when sending. Default: 1 Range: 0, 1 – CE Detection Time CE Detect Time Sets the time required to detect a communications error. Adjustment may be needed when networking several drives. Default: 2.0 s Min.: 0.0 Max.: 10.0 – H5-10 (0436) Unit Selection for MEMOBUS/Modbus Register 0025H CommReg 25h Unit 0: 0.1 V 1: 1 V 0: 0.1 V units 1: 1 V units Default: 0 Range: 0, 1 – H5-11 (043C) Communications ENTER Function Selection Enter CommandSel 0: Enter Required 1: No EnterRequired Default: 1 Range: 0, 1 – H5-12 (043D) Run CommandSel Run Command Method 0: FWD Run &REV Selection Run 1: Run & FWD/REV 0: Drive requires an Enter command before accepting any changes to parameter settings. 1: Parameter changes are activated immediately without the Enter command. 0: FWD/Stop, REV/Stop 1: Run/Stop, FWD/REV Default: 0 Range: 0, 1 – Parameter List <1> If this parameter is set to 0, the drive will be unable to respond to MEMOBUS/Modbus commands. <2> When P1-01, Pump Mode, is set to 3 (MEMOBUS network), the range is dependent on P9-25, Highest Node Address. B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 287 B.7 H Parameters: Multi-Function Terminals u H6: Pulse Train Input No. (Addr. Hex) Name LCD Display Description 0: Frequency reference 1: PID feedback value 2: PID setpoint value 5: Flow meter Values Page Default: 0 Range: 0 to 2; 5 – Pulse Train Input Terminal RP Function Selection Term RP Func Sel 0: Frequency Ref 1: PID Feedback 2: PID Set Point 5: Flow Meter Pulse Train Input Scaling Term RP Scaling H6-03 (042E) Pulse Train Input Gain Term RP Gain Sets the level of the value selected in H6-01 when a frequency Default: 100.0% with the value set in H6-02 is input. Min.: 0.0 Max.: 1000.0 – H6-04 (042F) Pulse Train Input Bias Term RP Bias Sets the level of the value selected in H6-01 when 0 Hz is input. Default: 0.0% Min.: -100.0 Max.: 100.0 – H6-01 (042C) H6-02 (042D) H6-05 (0430) H6-08 (043F) 288 Pulse Train Input Filter Term RP Flt Time Time Pulse Train Input Minimum Frequency RP Lower Limit Note: When this parameter is set to 5, parameters H6-02 to H6-04 and H6-08 are ignored. Sets the terminal RP input signal frequency that is equal to 100% Default: 1440 Hz of the value selected in H6-01. Min.: 100 Max.: 32000 Sets the pulse train input filter time constant. Sets the minimum frequency for the pulse train input to be detected. Enabled when H6-01 = 0, 1, or 2. – Default: 0.50 s Min.: 0.00 Max.: 2.00 – Default: 0.5 Hz Min.: 0.1 Max.: 1000.0 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.8 L: Protection Function B.8 L: Protection Function L parameters provide protection to the drive and motor, including control during momentary power loss, Stall Prevention, frequency detection, fault restarts, overtorque detection, and other types of hardware protection. u L1: Motor Protection No. (Addr. Hex) Name LCD Display L1-01 (0480) Motor Overload Protection Selection Mtr OL Charact 0: OL1 Disabled 1: VT Motor 2: CT Motor 3: Vector Motor 6: 50Hz VT Motor L1-02 (0481) Motor Overload Protection Time MOL Time Const L1-03 (0482) OH Alarm Sel Motor Overheat Alarm Mtr 0 : Ramp to Stop Operation Selection 1: Coast to Stop (PTC input) 2: Fast-Stop 3: Alarm only L1-04 (0483) Motor Overheat Fault Operation Selection (PTC input) L1-05 (0484) Motor Temperature Input Filter Time (PTC Mtr Temp Filter input) L1-13 (046D) Continuous Electrothermal Operation Selection Mtr OH Fault Sel 0 : Ramp to Stop 1: Coast to Stop 2: Fast-Stop Mtr OL Mem Sel 0: Disabled 1: Enabled 2: Enabled(RTC) Description Values 0: Disabled 1: General purpose motor (standard fan cooled) 2: Drive dedicated motor with a speed range of 1:10 Default: 1 3: Vector motor with a speed range of 1:100 Range: 0 to 3; 6 6: General purpose motor (50 Hz) The drive may not be able to provide protection when using multiple motors, even if overload is enabled in L1-01. Set L1-01 to 0 and install separate thermal relays to each motor. Sets the motor thermal overload protection (oL1) time. Default: 1.0 min Min.: 0.1 Max.: 5.0 Page – – Sets operation when the motor temperature analog input (H3-02, H3-10, or H3-06 = E) exceeds the oH3 alarm level. 0: Ramp to stop Default: 3 1: Coast to stop Range: 0 to 3 2: Fast Stop (decelerate to stop using the deceleration time in C1-09) 3: Alarm only (“oH3” will flash) – Sets stopping method when the motor temperature analog input (H3-02, H3-10, or H3-06 = E) exceeds the oH4 fault level. Default: 1 0: Ramp to stop Range: 0 to 2 1: Coast to stop 2: Fast Stop (decelerate to stop using the deceleration time in C1-09) – Adjusts the filter for the motor temperature analog input (H3-02, Default: 0.20 s H3-10, or H3-06 = E). Min.: 0.00 Max.: 10.00 – 0: Disabled 1: Enabled 2: Enabled (RTC) – Default: 1 Range: 0 to 2 u L2: Momentary Power Loss Ride-Thru Name LCD Display L2-01 (0485) PwrL Selection 0: Disabled Momentary Power Loss 1: Enbl with Timer 2: Enbl whl CPU act Operation Selection 3: KEB Mode 4: KEB Stop Mode 5: KEB Decel Stop L2-02 (0486) Momentary Power Loss PwrL Ridethru t Ride-Thru Time L2-03 (0487) Momentary Power Loss Minimum Baseblock PwrL Baseblock t Time Description 0: Disabled. Drive trips on Uv1 fault when power is lost. 1: Recover within the time set in L2-02. Uv1 will be detected if power loss is longer than L2-02. 2: Recover as long as CPU has power. Uv1 is not detected. 3: KEB deceleration for the time set to L2-02. 4: KEB deceleration as long as CPU has power. 5: KEB deceleration to stop. Sets the Power Loss Ride-Thru time. Enabled only when L2-01 = 1 or 3. Values Page Default: 2 Range: 0 to 5 – Default: <1> Min.: 0.0 s Max.: 25.5 s – Sets the minimum wait time for residual motor voltage decay before the drive output reenergizes after performing Power Loss Default: <1> Ride-Thru. Min.: 0.1 s Increasing the time set to L2-03 may help if overcurrent or overvoltage occur during Speed Search or during DC Injection Max.: 5.0 s Braking. – Parameter List No. (Addr. Hex) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 289 B.8 L: Protection Function No. (Addr. Hex) L2-04 (0488) Name LCD Display Momentary Power Loss PwrL V/F Ramp t Voltage Recovery Ramp Time Description Sets the time for the output voltage to return to the preset V/f pattern during Speed Search. Sets the DC bus undervoltage trip level. L2-05 (0489) Undervoltage Detection PUV Det Level Level (Uv1) Values Default: <1> Min.: 0.0 s Max.: 5.0 s Default: 190 Vdc <2> <3> Min.: 150 Vdc Max.: 210 Vdc Page – – <3> L2-06 (048A) KEB Deceleration Time KEB Decel Time L2-07 (048B) KEB Acceleration Time KEB Accel Time L2-08 (048C) Frequency Gain at KEB KEB Freq Red Start L2-10 (048E) KEB Detection Time (Minimum KEB Time) KEB Detect Time L2-11 (0461) DC Bus Voltage Setpoint during KEB KEB DC Bus Level Sets the time required to decelerate from the speed when KEB Default: 0.00 s was activated to zero speed. Min.: 0.00 Max.: 6000.0 <4> Sets the time to accelerate to the frequency reference when Default: 0.00 s momentary power loss is over. If set to 0.0, the active Min.: 0.00 acceleration time is used. Max.: 6000.0 <4> Sets the percentage of output frequency reduction at the Default: 100% beginning of deceleration when the KEB Ride-Thru function is Min.: 0 started. Max.: 300 Reduction = (slip frequency before KEB) × L2-08 × 2 Sets the time to perform KEB Ride-Thru. Default: 50 ms Min.: 0 Max.: 2000 Sets the desired value of the DC bus voltage during KEB Ride- Default: <2> Thru. [E1-01] × 1.22 Min.: 150 Vdc Max.: 400 Vdc – – – – – <5> L2-29 (0475) KEB Mode Sel 0: Single Mode KEB1 1: Single Mode KEB2 KEB Method Selection 2: System Mode KEB1 3: System Mode KEB2 0: Single Drive KEB Ride-Thru 1 1: Single Drive KEB Ride-Thru 2 2: System KEB Ride-Thru 1 3: System KEB Ride-Thru 2 Default: 0 Range: 0 to 3 – <1> <2> <3> <4> Default setting is dependent on parameter o2-04, Drive Model Selection. Default setting is dependent on parameter E1-01, Input voltage Setting. Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives. Setting range value is dependent on parameter C1-10, Accel/Decel Time Setting Units. When C1-10 = 0 (units of 0.01 seconds), the setting range becomes 0.00 to 600.00 seconds. <5> Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives, but set the value below 1040 Vdc (overvoltage protection level). u L3: Stall Prevention No. (Addr. Hex) Name LCD Display L3-01 (048F) Stall Prevention Selection during Acceleration StallP Accel Sel 0: Disabled 1: General purpose 2: Intelligent L3-02 (0490) Stall Prevention Level during Acceleration StallP Accel Lvl L3-03 (0491) Stall Prevention Limit during Acceleration StallPAcc LowLim 290 Description 0: Disabled. 1: General purpose. Acceleration is paused as long as the current is above the L3-02 setting. 2: Intelligent. Accelerate in the shortest possible time without exceeding the L3-02 level. Used when L3-01 = 1 or 2. 100% is equal to the drive rated current. Sets Stall Prevention lower limit during acceleration when operating in the constant power range. Set as a percentage of drive rated current. Values Default: 1 Range: 0 to 2 Default: <1> Min.: 0% Max.: 150% <1> Default: 50% Min.: 0 Max.: 100 Page – – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.8 L: Protection Function No. (Addr. Hex) Name LCD Display L3-04 (0492) Stall Prevention Selection during Deceleration StallP Decel Sel 0: Disabled 1: General purpose 2: Intelligent 3: StallP +Resistor 4: High Flux Brake 5: High Flux Brake2 L3-05 (0493) Stall Prevention Selection during Run StallP Run Sel 0: Disabled 1: Decel time 2: Decel time 2 L3-06 (0494) Stall Prevention Level during Run StallP Run Level L3-11 (04C7) Overvoltage Suppression Function Selection OV Inhibit Sel 0: Disabled 1: Enabled L3-17 (0462) Target DC Bus Voltage for Overvoltage DC Bus Reg Level Suppression and Stall Prevention L3-20 (0465) DC Bus Voltage Adjustment Gain DC Bus P Gain L3-21 (0466) Accel/Decel Rate Calculation Gain Acc/Dec P Gain Description 0: Disabled. Deceleration at the active deceleration rate. An ov fault may occur. 1: General purpose. Deceleration is paused when the DC bus voltage exceeds the Stall Prevention level. 2: Intelligent. Decelerate as fast as possible while avoiding ov faults. 3: Stall Prevention with braking resistor. Stall Prevention during deceleration is enabled in coordination with dynamic braking. 4: Overexcitation Deceleration. Decelerates while increasing the motor flux. 5: Overexcitation Deceleration 2. Adjust the deceleration rate according to the DC bus voltage. 0: Disabled. Drive runs at a set frequency. A heavy load may cause speed loss. 1: Decel time 1. Uses the deceleration time set to C1-02 while Stall Prevention is performed. 2: Decel time 2. Uses the deceleration time set to C1-04 while Stall Prevention is performed. Values Page Default: 0 Range: 0 to 5 – Default: 0 Range: 0 to 2 – Default: <1> Enabled when L3-05 is set to 1 or 2. 100% is equal to the drive Min.: 30% Max.: 150% rated current. V/f Enables or disables the ov suppression function, which allows the drive to change the output frequency as the load changes to prevent an ov fault. 0: Disabled 1: Enabled Sets the desired value for the DC bus voltage during overvoltage suppression and Stall Prevention during deceleration. <1> Default: 0 Range: 0, 1 Default: 375 Vdc <2> <3> Min.: 150 Max.: 400 <3> Sets the proportional gain for KEB Ride-Thru, Stall Prevention, Default: 1.00 (V/ and overvoltage suppression. f) 0.30 (OLV) Min.: 0.00 Max.: 5.00 Sets the proportional gain used to calculate the deceleration rate Default: 1.00 during KEB Ride-Thru, ov suppression function, and Stall Min.: 0.10 Prevention during deceleration (L3-04 = 2). Max.: 10.00 – – – – – V/f CHP Stall P Sel 0: Lv1 set in L3-06 1: Autom. Reduction L3-24 (046E) Motor Acceleration Time for Inertia Calculations Mtr Accel Time L3-25 (046F) Load Inertia Ratio Load Inertia Rat L3-26 (0455) Additional DC Bus Capacitors ExtDC busCapSize L3-27 (0456) Stall Prevention Detection Time Stl Prev DetTime 0: Sets the Stall Prevention level set in L3-06 that is used throughout the entire frequency range. 1: Automatic Stall Prevention level reduction in the constant output range. The lower limit value is 40% of L3-06. Default: 0 Range: 0, 1 Sets the time needed to accelerate the uncoupled motor at rated Default: <4> <5> torque from stop to the maximum frequency. Min: 0.001 s Max: 10.000 s Sets the ratio between the motor and machine inertia. Default: 1.0 Min.: 1.0 Max.: 1000.0 When DC bus capacitors have been added externally, be sure to Default: 0 μF add those values to the internal capacitor table for proper DC Min: 0 bus calculations. Max: 65000 Sets the time the current must exceed the Stall Prevention level Default: 50 ms to activate Stall Prevention. Min.: 0 Max.: 5000 – – – – – <1> Upper limit is dependent on parameter L8-38, Frequency Reduction Selection. <2> Default setting is dependent on parameter E1-01, Input voltage Setting. <3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives, but set the value below 1040 Vdc (overvoltage protection level). <4> Parameter value changes automatically if E2-11 is manually changed or changed by Auto-Tuning. <5> Default setting is dependent on parameter o2-04, Drive Model Selection. Parameter List Reduction L3-23 Automaticfor Stall (04FD) Selection Prevention during Run B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 291 B.8 L: Protection Function u L4: Speed Detection No. (Addr. Hex) Name LCD Display Description Values L4-01 (0499) Speed Agreement Detection Level Spd Agree Level L4-01 sets the frequency detection level for digital output functions H2-oo = 2, 3, 4, 5. L4-02 (049A) Speed Agreement Detection Width Spd Agree Width L4-02 sets the hysteresis or allowable margin for speed detection. L4-03 (049B) Speed Agreement Detection Level (+/-) Spd Agree Lvl+- L4-03 sets the frequency detection level for digital output functions H2-oo = 13, 14, 15, 16. L4-04 (049C) Speed Agreement Detection Width (+/-) Spd Agree Wdth+- L4-04 sets the hysteresis or allowable margin for speed detection. L4-05 (049D) Frequency Reference Loss Detection Selection Ref Loss Sel 0: Stop 1: Run@L4-06PrevRef 0: Stop. Drive stops when the frequency reference is lost. 1: Run. Drive runs at a reduced speed when the frequency reference is lost. Default: 0 Range: 0, 1 – L4-06 (04C2) Frequency Reference at Fref at Floss Reference Loss Sets the percentage of the frequency reference that the drive should run with when the frequency reference is lost. Default: 80.0% Min.: 0.0 Max.: 100.0 – L4-07 (0470) Speed Agreement Detection Selection Default: 0 Range: 0, 1 – Freq Detect Sel 0: No detection during baseblock. 0: No Detection @BB 1: Detection always enabled. 1: Always Detected Default: 0.0 Hz Min.: 0.0 Max.: 400.0 Default: 2.0 Min.: 0.0 Max.: 20.0 Default: 0.0 Hz Min.: -400.0 Max.: 400.0 Default: 2.0 Min.: 0.0 Max.: 20.0 Page – – – – u L5: Fault Restart No. (Addr. Hex) Name LCD Display L5-01 (049E) Number of Auto Restart Num of Restarts Attempts L5-02 (049F) Auto Restart Fault Output Operation Selection Restart Sel 0: Flt Outp Disabld 1: Flt Outp Enabled L5-04 (046C) Fault Reset Interval Time Flt Reset Wait T L5-40 (0670) Low Feedback Fault Retry Selection Low Feedback 0: No retry 1: Retry L5-41 (0671) High Feedback Fault Retry Selection High Feedback 0: No retry 1: Retry L5-42 (0672) Feedback Loss Fault Retry Selection Feedback Loss 0: No retry 1: Retry L5-50 (067A) Not Met Setpoint Not Met Retry SetPoint 0: No retry Selection 1: Retry L5-51 (067B) Loss of Prime Fault Retry Selection L5-52 (067C) Over Cycle Pump Over Cycle Fault Pump 0: No retry Retry Selection 1: Retry 292 High Feedback 0: No retry 1: Retry Description Values Page Sets the number of times the drive may attempt to restart after the following faults occur: GF, LF, oC, ov, PF, rH, rr, oL1, oL2, oL3, oL4, STo, Uv1. 0: Fault output not active. 1: Fault output active during restart attempt. Default: 5 Min.: 0 Max.: 10 – Default: 0 Range: 0, 1 – Sets the amount of time to wait between performing fault restarts. Default: 20.0 s Min.: 10.0 Max.: 3600.0 – Default: 0 Range: 0, 1 – Default: 0 Range: 0, 1 – Default: 0 Range: 0, 1 – Default: 0 Range: 0, 1 – Default: 0 Range: 0, 1 – Default: 0 Range: 0, 1 – Determines whether the LFB-Low Feedback fault can be autorestarted. 0: No retry 1: Retry Determines whether the HFB-High Feedback fault can be autorestarted. 0: No retry 1: Retry Determines whether the FBL-Feedback Loss fault can be autorestarted. 0: No retry 1: Retry Determines whether the NMS-Setpoint not Met fault can be auto-restarted. 0: No retry 1: Retry Determines whether the LOP-Loss of Prime fault can be autorestarted. 0: No retry 1: Retry Determines whether the POC-Pump Over Cycle fault can be auto-restarted. 0: No retry 1: Retry YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.8 L: Protection Function No. (Addr. Hex) L5-53 (067D) Name Volute-TStat Retry Selection LCD Display Volute-TStat Flt 0: No retry 1: Retry Description Determines whether the Volute T-Stat fault can be autorestarted. 0: No retry 1: Retry Note: The drive will restart only after the Volute-Tstat digital input deactivates and the L5-04 timer expires. Values Default: 0 Range: 0, 1 Page – u L6: Torque Detection Name LCD Display L6-01 (04A1) Torque Detection Selection 1 Torq Det 1 Sel 0: Disabled 1: OL Alm at SpdAgr 2: OL Alm dur RUN 3: OL Flt at SpdAgr 4: OL Flt dur RUN 5: UL Alm at SpdAgr 6: UL Alm dur RUN 7: UL Flt at SpdAgr 8: UL Flt dur RUN 9: UL6Alm at SpdAgr 10: UL6Alm dur RUN 11: UL6Flt at SpdAgr 12: UL6Flt dur RUN L6-02 (04A2) Torque Detection Level 1 Torq Det 1 Lvl L6-03 (04A3) Torque Detection Time 1 Torq Det 1 Time L6-04 (04A4) Torque Detection Selection 2 L6-05 (04A5) Torque Detection Level 2 L6-06 (04A6) Torque Detection Time 2 L6-13 (062E) Motor Underload Protection Selection Description Values 0: Disabled 1: oL3 detection only active during speed agree, operation continues after detection 2: oL3 detection always active during run, operation continues after detection 3: oL3 detection only active during speed agree, output shuts down on an oL3 fault 4: oL3 detection always active during run, output shuts down on an oL3 fault 5: UL3 detection only active during speed agree, operation Default: 0 continues after detection Range: 0 to 12 6: UL3 detection always active during run, operation continues after detection 7: UL3 detection only active during speed agree, output shuts down on an oL3 fault 8: UL3 detection always active during run, output shuts down on an oL3 fault 9: UL6 Alarm at Speed Agree 10: UL6 Alarm during Run 11: UL6 Fault at Speed Agree 12: UL6 Fault during Run Sets the overtorque and undertorque detection level. Default: 15% Min.: 0 Max.: 300 Sets the time an overtorque or undertorque condition must exist Default: 10.0 s to trigger torque detection 1. Min.: 0.0 Max.: 10.0 0: Disabled 1: oL4 detection only active during speed agree, operation continues after detection 2: oL4 detection always active during run, operation continues Torq Det 2 Sel after detection 0: Disabled 1: OL Alm at SpdAgr 3: oL4 detection only active during speed agree, output shuts 2; OL Alm dur RUN down on an oL4 fault 3: OL Flt at SpdAgr 4: oL4 detection always active during run, output shuts down Default: 0 on an oL4 fault 4: OL Flt dur RUN Range: 0 to 8 5: UL Alm at SpdAgr 5: UL4 detection only active during speed agree, operation continues after detection 6: UL Alm dur RUN 7: UL Flt at SpdAgr 6: UL4 detection always active during run, operation continues after detection 8: UL Flt dur RUN 7: UL4 detection only active during speed agree, output shuts down on an oL4 fault 8: UL4 detection always active during run, output shuts down on an oL4 fault Sets the overtorque and undertorque detection level. Default: 150% Torq Det 2 Lvl Min.: 0 Max.: 300 Sets the time an overtorque or undertorque condition must exist Default: 0.1 s Torq Det 2 Time to trigger torque detection 2. Min.: 0.0 Max.: 10.0 Underload Select Sets the motor underload protection (UL6) based on motor load. Default: 0 0: Base Freq Enable 0: Base frequency enable Range: 0, 1 1: Max Freq Enable 1: Max frequency enable YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Page – – – – – – – Parameter List No. (Addr. Hex) B 293 B.8 L: Protection Function No. (Addr. Hex) L6-14 (062F) Name Motor Underload Protection Level at Minimum Frequency LCD Display Underload Level Description Values Sets the UL6 detection level at minimum frequency by percentage of drive rated current. Default: 15% Min.: 0 Max.: 300 Page – u L7: Torque Limit No. (Addr. Hex) Name LCD Display Description Values OLV Default: 200% Min.: 0 Max.: 300 Default: 200% Min.: 0 Max.: 300 L7-01 (04A7) Forward Torque Limit Torq Limit Fwd L7-02 (04A8) Reverse Torque Limit Torq Limit Rev L7-03 (04A9) Forward Regenerative Torque Limit Torq Lmt Fwd Rgn L7-04 Reverse Regenerative (04AA) Torque Limit Torq Lmt Rev Rgn L7-06 Torque Limit Integral (04AC) Time Constant Trq Lim I Time Sets the integral time constant for the torque limit. Trq Lim d AccDec 0: P-ctrl @ Acc/Dec 1: I-ctrl @ Acc/Dec 0: Proportional control (changes to integral control at constant speed). Use this setting when acceleration to the desired speed Default: 0 Range: 0, 1 should take precedence over the torque limit. 1: Integral control. Set L7-07 to 1 if the torque limit should take precedence. Sets the torque limit value as a percentage of the motor rated torque. Four individual quadrants can be set. Output Torque Positive Torque L7-01 L7-04 Motor r/min Regeneration REV FWD Regeneration L7-02 L7-03 Negative Torque OLV Page – – Default: 200% Min.: 0 Max.: 300 – Default: 200% Min.: 0 Max.: 300 – Default: 200 ms Min: 5 Max: 10000 – OLV L7-07 (04C9) Torque Limit Control Method Selection during Accel/Decel – u L8: Drive Protection No. (Addr. Hex) Name LCD Display Internal Dynamic L8-01 Braking Resistor (04AD) Protection Selection (ERF type) DB Resistor Prot 0: Not Provided 1: Provided L8-02 (04AE) Overheat Alarm Level OH Pre-Alarm Lvl L8-03 Overheat Pre-Alarm (04AF) Operation Selection OH Pre-Alarm Sel 0: Ramp to stop 1: Coast to stop 2: Fast-Stop 3: Alarm only 4: Run@L8-19 Rate L8-05 (04B1) Input Phase Loss Protection Selection Inp Ph Loss Det 0: Disabled 1: Enabled L8-07 (04B3) Output Phase Loss Protection Selection L8-09 (04B5) Output Ground Fault Detection Selection 294 Outp Ph Loss Det 0: Disabled 1: 1PH Loss Det 2: 2/3PH Loss Det Grnd Flt Det Sel 0: Disabled 1: Enabled Description 0: Resistor overheat protection disabled 1: Resistor overheat protection enabled Values Default: 0 Range: 0, 1 An overheat alarm occurs when heatsink temperature exceeds Default: <1> the L8-02 level. Min.: 50 °C Max.: 150 °C 0: Ramp to stop. A fault is triggered. 1: Coast to stop. A fault is triggered. 2: Fast Stop. Decelerate to stop using the deceleration time in Default: 3 Range: 0 to 4 C1-09. A fault is triggered. 3: Continue operation. An alarm is triggered. 4: Continue operation at reduced speed as set in L8-19. Selects the detection of input current phase loss, power supply voltage imbalance, or main circuit electrolytic capacitor Default: 1 deterioration. Range: 0, 1 0: Disabled 1: Enabled 0: Disabled Default: 1 1: Enabled (triggered by a single phase loss) Range: 0 to 2 2: Enabled (triggered when two phases are lost) 0: Disabled 1: Enabled Default: 1 Range: 0, 1 Page – – – – – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.8 L: Protection Function No. (Addr. Hex) Name LCD Display Description L8-10 (04B6) Heatsink Cooling Fan Operation Selection Fan On/Off Sel 0: Dur Run (OffDly) 1: Always On L8-11 (04B7) Heatsink Cooling Fan Off Delay Time Fan Delay Time 0: During run only. Fan operates only during run for L8-11 seconds after stop. 1: Fan always on. Cooling fan operates whenever the drive is powered up. Sets a delay time to shut off the cooling fan after the Run command is removed when L8-10 = 0. L8-12 (04B8) Ambient Temperature Setting Ambient Temp Enter the ambient temperature. This value adjusts the oL2 detection level. L8-15 oL2 Characteristics (04BB) Selection at Low Speeds OL2 Sel @ L-Spd 0: Disabled 1: Enabled L8-18 Software Current Limit Soft CLA Sel 0: Disabled (04BE) Selection 1: Enabled L8-19 Frequency Reduction Fc Red dur OHAlm (04BF) Rate during Overheat Pre-Alarm Values Default: 0 Range: 0, 1 Default: 300 s Min.: 0 Max.: 300 Default: 40 °C Min.: -10 Max.: 50 Page – – – 0: No oL2 level reduction below 6 Hz. Default: 1 1: oL2 level is reduced linearly below 6 Hz. It is halved at 0 Hz. Range: 0, 1 – 0: Disabled 1: Enabled Default: 0 Range: 0, 1 – Specifies the frequency reference reduction gain at overheat pre- Default: 0.8 alarm when L8-03 = 4. Min.: 0.1 Max.: 0.9 – MC/FAN PS FltSel 0: Ramp to stop 1: Coast to stop 2: Fast-Stop 3: Alarm only 4: Run@L8-19 Rate Determines drive response when a fault occurs with the internal cooling fan. 0: Ramp to stop Default: 1 1: Coast to stop 2: Fast stop (Decelerate to stop using the deceleration time set Range: 0 to 4 to C1-09) 3: Alarm only (“FAn” will flash) 4: Continue operation at reduced speed as set to L8-19. – L8-35 Installation Method (04EC) Selection Installation Sel 0: IP00/OpenChassis 1: Side-by-Side 2: IP20/Nema Type 1 3: ExternalHeatsink 0: IP00/Open-Chassis enclosure 1: Side-by-Side mounting 2: IP20/NEMA Type 1 enclosure 3: Finless model drive or external heatsink installation Default: <2> <3> Range: 0 to 3 – L8-38 (04EF) Carrier Frequency Reduction Fc Reduct dur OL 0: Disabled 1: Active below 6Hz 2: Active @ any Spd 0: Disabled 1: Enabled below 6 Hz 2: Enabled for the entire speed range Default: 2 Range: 0 to 2 – L8-40 (04F1) Carrier Frequency Reduction Off Delay Time Fc Reduct Time Sets the time that the drive continues running with reduced Default: 0.5 s carrier frequency after the carrier reduction condition is gone. Min.: 0.00 Setting 0.00 s disables the carrier frequency reduction time. Max.: 2.00 – L8-41 (04F2) High Current Alarm Selection L8-55 (045F) Internal Braking Transistor Protection High Cur Alm Sel 0: Disabled 1: Enabled FC Sel dur OHAlm 0: Disabled 1: Enabled 0: Disabled 1: Enabled. An alarm is triggered at output currents above 150% of drive rated current. 0: Disabled. Disable when using a regen converter or optional braking unit. 1: Protection enabled. L8-32 (04E2) Main Contactor and Cooling Fan Power Supply Failure Selection Default: 0 Range: 0, 1 – Default: 1 Range: 0, 1 – Parameter List <1> Default setting is dependent on parameter o2-04, Drive Model Selection. <2> Parameter setting value is not reset to the default value when the drive is initialized. <3> Default setting is determined by the drive model: Setting 2: Model code 2A0004 to 2A0211, 4A0002 to 4A0165, and 5A0003 to 5A0242 Setting 0: Model code 2A0250 to 2A0415 and 4A0208 to 4A0675 B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 295 B.9 n: Special Adjustment B.9 n: Special Adjustment The n parameters adjust more advanced performance characteristics such as Hunting Prevention, High Slip Braking, and Overexcitation Braking. u n1: Hunting Prevention No. (Addr. Hex) Name LCD Display Description n1-01 (0580) Hunting Prevention Selection Hunt Prev Select 0: Disabled 1: Enabled n1-02 (0581) Hunting Prevention Gain Setting Hunt Prev Gain n1-03 (0582) Hunting Prevention Time Constant Hunt Prev Time Sets the time constant used for Hunting Prevention. n1-05 (0530) Hunting Prevention Gain while in Reverse Hprev Gain @Rev V/f Values Default: 1 Range: 0, 1 0: Disabled 1: Enabled Page – V/f Default: 1.00 If the motor vibrates while lightly loaded, increase the gain by Min.: 0.00 0.1 until vibration ceases. If the motor stalls, decrease the gain Max.: 2.50 by 0.1 until the stalling ceases. – Default: <1> Min.: 0 ms Max.: 500 ms – V/f Default: 0.00 Sets the gain used for Hunting Prevention. If set to 0, the gain Min.: 0.00 Max.: 2.50 set to n1-02 is used for operation in reverse. – V/f <1> Default setting is dependent on parameter o2-04, Drive Model Selection. u n2: Speed Feedback Detection Control (AFR) Tuning No. (Addr. Hex) Name LCD Display Description Values Page OLV n2-01 (0584) Speed Feedback Detection Control (AFR) Gain n2-02 (0585) Speed Feedback AFR Time Detection Control (AFR) Time Constant 1 OLV Default: 50 ms Sets the time constant used for speed feedback detection control Min.: 0 Max.: 2000 (AFR). – n2-03 (0586) Speed Feedback AFR Time 2 Detection Control (AFR) Time Constant 2 OLV Default: 750 ms Sets the AFR time constant to be used during Speed Search and Min.: 0 Max.: 2000 during regen. – AFR Gain Sets the internal speed feedback detection control gain in the automatic frequency regulator (AFR). If hunting occurs, increase the set value. If response is low, decrease the set value. Default: 1.00 Min.: 0.00 Max.: 10.00 – u n3: High Slip Braking (HSB) and Overexcitation Braking No. (Addr. Hex) Name LCD Display Description Values Page V/f n3-01 (0588) High-Slip Braking Deceleration Frequency HSB DecStepWidth Width n3-02 (0589) High-Slip Braking Current Limit Default: 5% Sets the output frequency reduction step width for when the Min.: 1 drive stops the motor using HSB. Set as a percentage of the maximum output frequency. Increase this setting if overvoltage Max.: 20 occurs during HSB. Default: <1> Sets the current limit during HSB as a percentage of the motor Min.: 100% Max.: 200% rated current. – V/f HSB Current Lim – V/f n3-03 (058A) 296 High-Slip Braking Dwell Time at Stop HSB DwelTim@Stp Default: 1.0 s Sets the time the drive will run with minimum frequency Min.: 0.0 (E1-09) at the end of deceleration. If this time is set too low, the machine inertia can cause the motor Max.: 10.0 to rotate slightly after HSB. – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.9 n: Special Adjustment No. (Addr. Hex) Name LCD Display Description Values Page V/f HSB OL Time Default: 40 s Sets the time required for an HSB overload fault (oL7) to occur Min.: 30 when the drive output frequency does not change during an HSB Max.: 1200 stop. This parameter does not typically require adjustment. – Overexcitation Deceleration Gain Hflux Brake Gain Sets the gain applied to the V/f pattern during Overexcitation Deceleration (L3-04 = 4). Default: 1.10 Min.: 1.00 Max.: 1.40 – n3-14 (0532) High Frequency Injection during Overexcitation Deceleration HarmInj@HiFlxBrk 0: Disabled 1: Enabled Default: 0 Range: 0, 1 – n3-21 (0579) High-Slip Suppression Current Level Hflux I Supp Lvl Default: 100% Min.: 0 Max.: 150 – n3-23 (057B) Overexcitation Operation Selection Hflux Brake Sel 0: Enabled-Both Dir 1: Enabled-Fwd only 2: Enabled-Rev only Default: 0 Range: 0 to 2 – n3-04 (058B) High-Slip Braking Overload Time n3-13 (0531) Sets output current level at which the drive will start reducing the overexcitation gain in order to prevent a too high motor slip during Overexcitation Deceleration. Set as a percentage of the drive rated current. 0: Enabled in both directions 1: Enabled only when rotating forward 2: Enabled only when in reverse <1> Default setting is dependent on parameter L8-38, Frequency Reduction Selection. u n6: Online Tuning No. (Addr. Hex) n6-01 (0570) Name Online Tuning Selection LCD Display Online Tune Sel 0: Disabled 1: TerminalResAdj 2: VoltageAdjustm Description Values Page OLV 0: Disabled Default: 0 1: Line-to-line resistance tuning Range: 0 to 2 2: Voltage correction. Setting not possible when Energy Saving is enabled (b8-01). – OLV Online Tuning Gain R1 Comp Gain Default: 1.0 Decrease this setting for motors with a relatively large rotor time Min.: 0.1 constant. If overload occurs, increase this setting slowly in Max.: 50.0 increments of 0.10. – Parameter List n6-05 (05C7) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 297 B.10 o: Operator-Related Settings B.10 o: Operator-Related Settings The o parameters set up the HOA keypad displays. u o1: HOA Keypad Display Selection No. (Addr. Hex) o1-01 (0500) o1-02 (0501) Name Drive Mode Unit Monitor Selection LCD Display User Monitor Sel Power-On Monitor 1: Frequency Ref User Monitor Selection 2: FWD/REV after Power Up 3: Output Freq 4: Output Current 5: User Monitor Display Unit Sel 0: 0.01 Hz 1: 0.01% 2: r/min 3: User Units o1-03 (0502) Digital Operator Display Selection o1-06 (0517) Mode Sel User Monitor Selection Monitor 0: 3 Mon Sequential Mode 1: 3 Mon Selectable o1-07 (0518) Second Line Monitor Selection 2nd Monitor Sel Description Selects the content of the last monitor that is shown when Default: 106 scrolling through Drive Mode display. Enter the last three digits (Monitor U1-06) Range: 104 to of the monitor parameter number to be displayed: Uo-oo. 699 1: Frequency reference (U1-01) 2: Direction Default: 1 3: Output frequency (U1-02) Range: 1 to 5 4: Output current (U1-03) 5: User-selected monitor (set by o1-01) Sets the units the drive should use to display the frequency reference and motor speed monitors. 0: 0.01 Hz 1: 0.01% (100% = E1-04) 2: r/min (calculated using the number of motor poles setting in E2-04) 3: User-selected units (set by o1-09, o1-10 and o1-11) Selects the monitors displayed on the second and third lines of the digital operator display. 0: 3 Monitor Sequential (displays the next two sequential monitors) 1: 3 Monitor Selectable (set by o1-07 and o1-08) Selects the monitor that is shown in the second line. Enter the last three digits of the monitor parameter number to be displayed: Uo-oo. For example, set "403" to display monitor parameter U4-03. Note: o1-08 (0519) Third Line Monitor Selection 3rd Monitor Sel Parameter is effective only when o1-06 is set to 1. Selects the monitor that is shown in the third line. Enter the last three digits of the monitor parameter number to be displayed: Uo-oo. For example, set "403" to display monitor parameter U4-03. Note: Fref Disp Unit 0: "WC:InchOfWater 1: PSI :lb/SqrInch 2: GPM:Gallons/Min 3: °F:DegFarenheit 4: CFM:Cubic ft/Min 5: CMH:Cubic m/Hr 6: LPH:Litres/Hr 7: LPS:Litres/Sec 8: Bar:Bar 9: Pa:Pascals 10: °C:DegCelsius 11: m: meters 12: ft: feet 13: LPM:Litres/Min 14: CMM:Cubic M/ Min 15: "Hg:Inch Mercury 24: Custom Unit 25: No Unit o1-09 (051C) Frequency Reference Display Units o1-10 (0520) User-Set Display Units UserDisp Scaling Maximum Value o1-11 (0521) User-Set Display Units UserDisp Dec Decimal Display 298 Values Parameter is effective only when o1-06 is set to 1. Sets unit display for the frequency reference parameters and frequency related monitors when o1-03 = 3. 0: WC (Inch of water) 1: PSI (Pounds per square inch) 2: GPM (Gallons per minute) 3: F (Degrees Fahrenheit) 4: CFM (Cubic feet per minute) 5: CMH (Cubic meters per hour) 6: LPH (Liters per hour) 7: LPS (Liters per second) 8: Bar (Bar) 9: Pa (Pascal) 10: C (Degrees Celsius) 11: Mtr (Meters) 12: Ft (Feet) 13: LPM (Liters per minute) 14: CMM (Cubic meters per minute) 15: “Hg (inches of mercury) 24: Custom units (determined by o1-13 to o1-15) 25: None Page – – Default: 0 Range: 0 to 3 – Default: 1 Range: 0, 1 – Default: 102 Range: 101 to 699 – Default: 191 Range: 101 to 699 – Default: 25 Range: 0 to 15; 24, 25 – These settings define the display values when o1-03 is set to 3. Default: <1> o1-10 sets the display value that is equal to the maximum output Range: 1 to frequency. 60000 o1-11 sets the position of the decimal position. Default: <1> Range: 0 to 3 – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.10 o: Operator-Related Settings No. (Addr. Hex) o1-12 (0522) o1-13 (3105) o1-14 (3106) o1-15 (3107) Name Home Help Text LCD Display Top Help on Home 0: Disabled 1: Enabled Frequency Reference and Frequency Related Fref Cust Unit 1 Monitor Custom Units 1 Frequency Reference and Frequency Related Fref Cust Unit 2 Monitor Custom Units 2 Frequency Reference and Frequency Related Fref Cust Unit 3 Monitor Custom Units 3 Description Switches the top line of the Home Screen from the Drive Status to defined Help messages. 0: Disabled 1: Enabled Sets the first character of the customer-specified unit display when o1-03 is set to 3 and o1-09 is set to 24. Values Page Default: 1 Range: 0, 1 – Default: 41 Range: 30 to 7A – Sets the second character of the customer-specified unit display Default: 41 when o1-03 is set to 3 and o1-09 is set to 24. Range: 30 to 7A – Sets the third character of the customer-specified unit display when o1-03 is set to 3 and o1-09 is set to 24. Default: 41 Range: 30 to 7A – Values Page <1> Default setting is dependent on parameter o1-03, Digital Operator Display Selection. u o2: HOA Keypad Keypad Functions No. (Addr. Hex) Name LCD Display Oper STOP Key 0: Disabled 1: Enabled o2-02 (0506) STOP Key Function Selection o2-03 (0507) User Default Sel User Parameter Default 0: No Change Value 1: Save User Init 2: Clear User Init o2-04 (508) Drive Model Selection Inverter Model # o2-05 (0509) Frequency Reference Setting Method Selection Operation Selection when Digital Operator is Disconnected Oper Ref Method 0: Disabled 1: Enabled Oper Discon Det 0: Disabled 1: Enabled o2-07 (0527) Motor Direction at Power Up when Using Operator For/RevSel@PwrUp 0: Forward 1: Reverse o2-19 (0527) ParameterSet Sel Parameter Set Selection 0: Disabled 1: Enabled o2-30 (1230) Monitor Position Save Mon Pos Save 0: Disabled 1: Enabled 0: Disabled. STOP key is disabled in REMOTE operation. 1: Enabled. STOP key is always enabled. 0: No change. 1: Set defaults. Saves parameter settings as default values for a User Initialization. 2: Clear all. Clears the default settings that have been saved for a User Initialization. Enter the drive model. Setting required only if installing a new control board. 0: ENTER key must be pressed to enter a frequency reference. 1: ENTER key is not required. The frequency reference can be adjusted using the up and down arrow keys only. 0: The drive continues operating if the digital operator is disconnected. 1: An oPr fault is triggered and the motor coasts to stop. This parameter requires assigning drive operation to the digital operator. 0: Forward 1: Reverse Selects whether parameter settings can be changed during a DC bus undervoltage condition. Used with 24 V Power Supply (PSA10L, PS-A10H). 0: Disabled 1: Enabled Saves the monitor position and Home Screen quick monitor selection. Setting this parameter to 0 and then entering the Monitor Menu will jump the selection to the monitor number instead of the group number. 0: Disabled 1: Enabled Default: 1 Range: 0, 1 – Default: 0 Range: 0 to 2 – Default: Determined by drive capacity – Default: 0 Range: 0, 1 – Default: 1 Range: 0, 1 – Default: 0 Range: 0, 1 – Default: 0 Range: 0, 1 – Default: 0 Range: 0, 1 – Parameter List o2-06 (050A) Description B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 299 B.10 o: Operator-Related Settings u o3: Copy Function No. (Addr. Hex) Name LCD Display Description COPY SELECT 0: COPY SELECT 1: INV→OP READ 2: OP→INV WRITE 3: OP←→INV VERIFY 0: No action 1: Read parameters from the drive, saving them onto the digital operator. 2: Copy parameters from the digital operator, writing them to the drive. 3: Verify parameter settings on the drive to check if they match the data saved on the operator. 0: Read operation prohibited 1: Read operation allowed o3-01 (0515) Copy Function Selection o3-02 (0516) Read Allowable Copy Allowed Selection 0: Disabled 1: Enabled Values Page Default: 0 Range: 0 to 3 – Default: 1 Range: 0, 1 – u o4: Maintenance Monitor Settings No. (Addr. Hex) Name LCD Display Description Values Page o4-01 (050B) Cumulative Operation Time Setting DrvElapsTimeCnt Sets the value for the cumulative operation time of the drive in Default: 0 units of 10 h. Min.: 0 Max.: 9999 – o4-02 (050C) Cumulative Operation Time Selection ElapsTimeCntSet 0: Power-On Time 1: Running Time 0: Logs power-on time Default: 1 1: Logs operation time when the drive output is active (output Range: 0, 1 operation time). – o4-03 (050E) Cooling Fan Operation FanElapsTimeCn Time Setting Sets the value of the fan operation time monitor U4-03 in units Default: 0 of 10 h. Min.: 0 Max.: 9999 – o4-05 (051D) Capacitor Maintenance BusCap Maint Set Setting Sets the value of the Maintenance Monitor for the capacitors. See U4-05 to check when the capacitors may need to be replaced. Default: 0% Min.: 0 Max.: 150 – o4-07 (0523) DC Bus Pre-Charge Relay Maintenance Setting ChrgCircMaintSet Sets the value of the Maintenance Monitor for the soft charge bypass relay. See U4-06 to check when the bypass relay may need to be replaced. Default: 0% Min.: 0 Max.: 150 – o4-09 (0525) IGBT Maintenance Setting IGBT Maint Set Sets the value of the Maintenance Monitor for the IGBTs. See Default: 0% U4-07 for IGBT replacement times. Min.: 0 Max.: 150 – o4-11 (0510) U2, U3 Initialization Fault Data Init 0: No Reset 1: Reset o4-12 (0512) kWh Monitor Initialization kWh Monitor Init 0: No Reset 1: Reset o4-13 (0528) Number of Run Commands Counter Initialization Run Counter Init 0: No Reset 1: Reset o4-17 (3100) Set/Reset Real-Time Clock o4-20 (081F) Time Display Format 300 Date/Time Config 0: — — 1: Set 2: Reset Time Disp Format 0: 12-hour (AM/PM) 1: 24-hour 0: U2-oo and U3-oo monitor data is not reset when the drive is initialized (A1-03). 1: U2-oo and U3-oo monitor data is reset when the drive is initialized (A1-03). 0: U4-10 and U4-11 monitor data is not reset when the drive is initialized (A1-03). 1: U4-10 and U4-11 monitor data is reset when the drive is initialized (A1-03). 0: Number of Run commands counter is not reset when the drive is initialized (A1-03). 1: Number of Run commands counter is reset when the drive is initialized (A1-03). Sets the current date and time for the Real-Time Clock. 0: - 1: Set 2: Reset Sets the time display format. 0: 12-hour 1: 24-hour Default: 0 Range: 0, 1 – Default: 0 Range: 0, 1 – Default: 0 Range: 0, 1 – Default: 0 Range: 0 to 2 Default: 0 Range: 0, 1 110 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.11 P: Pump Parameters B.11 P: Pump Parameters u P1: Pump Basic P1-01 (0C00) Name Pump Mode P1-02 (0C01) System Units P1-03 (0C02) Feedback Device Scaling P1-04 (0C03) Start / Draw Down Level LCD Display Pump Mode 0: Drive Only 1: Contactor Lag 3: Memobus Network System Units 0: No Unit 1: PSI :lb/SqrInch 2: Pa:Pascals 3: Bar:Bar 4: "WC:InchOfWater 5: "Hg:Inch Mercury 6: ft: feet 7: m: meters 8: °F:DegFarenheit 9: °C:DegCelsius 10: %: Percent 25: Flow (use P6-04) Description Default: 0 Range: 0, 1, 3 164 0: No unit 1: PSI: Pounds per square inch 2: Pa: Pascals 3: Bar: Bar 4: ”WC: Inch of water 5: ”Hg: Inch of Mercury 6: ft: feet 7: m: meters 8: °F: Degrees Fahrenheit 9: °C: Degrees Celsius 10: Percent 25: Flow (Use P6-04) <1> Default: 1 Range: 0 to 10; 25 165 Default: 145.0 PSI <2> Min.: 0.1 Max.: 6000.0 165 Sets the scaling of feedback device in user-set units. The system starts when the feedback level drops below the start level for the time set in P1-05. This level also specifies the wakeup level when the drive is in Sleep Mode. When this parameter is set to a negative value, the feedback level must drop that amount below the setpoint. Default: 0.0 Setting this parameter to 0.0 disables the function. When P1-01, Min.: -999.9 Pump Mode, is set to 3 (MEMOBUS network), this function is Max.: 999.9 active only on the first drive in the network. Note: P1-05 (0C02) P1-06 (0C05) P1-07 (0C06) <3> P1-08 (0C07) Start Level Delay Time S-Lev Delay Time Minimum Pump Speed Min. Pump Speed Minimum Pump Speed MinPumpSpdUnits 0: Hz Units 1: RPM Low Feedback Level Page 0: Drive only 1: Contactor lag 3: MEMOBUS network FB Dev. Scaling Start-DrawDn Lvl Values 165 When PID operates in reverse mode, the system will start when the feedback has risen above the start level for the time set to P1-05. The system starts when the feedback level drops below the start Default: 1 s Min.: 0 level for the time set in this parameter. Max.: 3600 Minimum frequency at which the drive will run. Applies to both HAND and Automatic modes. Default: 40.0 Hz Note: For minimum pump frequency, the drive will use <3> Min.: 0.0 the highest setting from among P1-06, P4-12 (Thrust Bearing Frequency), or d2-02 (Reference Max.: [E1-04] Lower Limit). Sets the units and decimal place for parameter P1-06. 0: Hz Default: 0 1: RPM Range: 0, 1 Note: Changing this parameter will reset the P1-06 default value. Sets the lower detection level for the PID feedback. Default: 0.0 PSI <2> Low FB Level Min.: 0.0 Max.: 6000.0 165 166 – 166 Sets the amount of delay time from when the low feedback is detected until the drive faults on an “LFB Low Feedback” fault. P1-09 (0C08) Low Feedback Level Fault Delay Time Low Lvl FLT Time Note: 1. This parameter is effective only when P1-10 Default: 10 s Min.: 0 is set to 0 (Fault). 2. When P1-01 is set to 3, parameter P9-18 uses Max.: 3600 this value to calculate the quick de-stage feedback level. 166 Parameter List No. (Addr. Hex) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 301 B.11 P: Pump Parameters No. (Addr. Hex) Name P1-10 (0C09) Low Feedback Selection P1-11 (0C0A) High Feedback Level LCD Display Low FB Sel 0: Fault 1: Alarm 2: Digital Output Selects drive response during the “Low Feedback” condition. 0: Fault 1: Alarm 2: Digital out only Sets the upper detection level for the PID feedback. High FB Level P1-12 (0C0B) High Feedback Level Fault Delay Time High Lvl FLT Time P1-13 High Feedback (0C0C) Selection High FB Sel 0: Fault 1: Alarm 2: Digital Output P1-14 (0C0D) Hysteresis Level Description Hysteresis Level Values Default: 0 Range: 0 to 2 166 Default: 155.0 PSI <2> Min.: 0.0 Max.: 6000.0 166 Sets the amount of delay time from when the high feedback is detected until the drive faults on a “HFB High Feedback” fault. Default: 5 s Min.: 0 Note: This parameter is effective only when P1-13 is set Max.: 3600 to 0 (Fault (and digital out)). Selects drive response during the “High Feedback” condition. Default: 0 0: Fault Range: 0 to 2 1: Alarm 2: Digital out only Sets the hysteresis level used for low and high level feedback detection. Page 166 166 Default: 0.0 PSI <2> Min.: 0.0 Max.: 100.0 – Max Set Pnt Diff Sets the level that the difference between the setpoint and the feedback must exceed for the time set in P1-16 to trigger the drive response set in P1-17. Default: 0.0 PSI If P1-17 is set to 1 (Fault and digital out), the will coast to stop. <2> This function is active when the drive is running during AUTO Min.: 0.0 Mode. When P1-01 is set to 3 (MEMOBUS network), the Max.: 6000.0 function is active on the lead drive and will stop all drives running on the network when The NMS fault occurs. Setting this parameter to 0.0 disables the function. – Not Maintaining Setpoint Time Not Maint SP Tm Sets the delay time before a “Setpoint Not Met” condition Default: 60 s occurs. The pump protection criteria set in P1-15 must be met Min.: 0 before the timer will start. Max.: 3600 Setting P1-15 to 0.0 disables this function. – P1-17 (0C10) Not Maintaining Setpoint Selection Not Maint SP Sel 0: Fault 1: Alarm 2: Digital Output Selects the drive response method during the “Not Maintaining Setpoint” condition. Default: 0 0: Fault Range: 0 to 2 1: Alarm 2: Digital out only – P1-18 (0C11) Prime Loss Detection Method Prime Loss Mthd 0: Current (A) 1: Power (kW) 2: Torque (%) Determines the quantity used to determine loss of prime. 0: Current (A) 1: Power (kW) 2: Torque (%) Detects loss of prime in the pump when in Auto or Sleep Boost Mode. When the measured quantity determined by P1-18 drops below this level for the time set in P1-20 and the output frequency is above the level set in P1–21, a “Loss of Prime” condition occurs. The drive responds to the “Loss of Prime” condition depending on the setting of P1-22, Loss of Prime Selection. Sets the delay time before a “Loss of Prime” condition occurs. The pump protection criteria set in P1-18 and P1-19 must be met before the timer will start. P1-15 (0C0E) Maximum Setpoint Difference P1-16 (0C0F) P1-19 (0C12) Prime Loss Level Prime Loss Level P1-20 (0C13) Loss of Prime Time Prime Loss Time P1-21 (0C14) Loss of Prime Frequency Prime Loss Freq P1-22 (0C15) Prime Loss Sel Fault Loss of Prime Selection 0: 1: Alarm 2: Digital Output P1-23 (0C16) Loss of Prime Maximum Restart Time LOP Max Rstrt T after Fault 302 Sets the frequency level above which the “Loss of Prime” detection is enabled when set to a value other than 0. When set to 0 (default), the frequency level is determined by the smaller value between (Fmax - 1 Hz) and (d2-01 - 1 Hz). Sets the drive response method during the “Loss of Prime” condition. 0: Fault 1: Alarm 2: Digital out only Sets the time in minutes that the drive will wait before attempting another restart when the restart fails or is not attempted due to a continuing fault condition. Default: 0 Range: 0 to 2 – Default: 0.0 A <4> Min.: 0.0 Max.: 1000.0 – Default: 20 s Min.: 0 Max.: 600 – Default: 0.0 Hz Min.: 0.0 Max.: [E1-04] – Default: 0 Range: 0 to 2 – Default: 0.2 min Min.: 0.2 Max.: 6000.0 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.11 P: Pump Parameters No. (Addr. Hex) Name LCD Display P1-30 Low Water Digital Input Low Water DI Sel 0: Normally Open (0C1D) Configuration 1: Normally Closed HighWater DI Sel P1-31 High Water Digital 0: Normally Open (0C1E) Input Configuration 1: Normally Closed Description Selects the configuration of the low water level digital input. 0: Normally open 1: Normally closed Selects the configuration of the high water level digital input. 0: Normally open 1: Normally closed Values Page Default: 0 Range: 0, 1 – Default: 0 Range: 0, 1 – <1> System units are set by P6-04, Water Flow Units. The PID Feedback is re-routed to come from the flow meter, pulse input (H6-01 = 5), or analog (H3-0o = 22). <2> Unit text is set by P1-02, System Units. <3> Unit range and resolution are determined by P1-07, Minimum Pump Speed Units. Setting P1-07 to 1 (RPM) will set a default value of 1800 RPM (VTC) and 2400 RPM (all others). Setting P1-07 to 0 (Hz, default) will set a default value of 40.0 Hz. <4> Unit text is set by P1-18, Prime Loss Detection Method. u P2: Pump Protection P2-01 (0C64) Name Sleep Level Type LCD Display Sleep Lvl Type 0: Output Frequency 1: Output Current 2: Feedback 3: Output Speed-RPM 4: Flow Meter Description 0: Output frequency 1: Output current 2: Feedback 3: Output speed (RPM) 4: Flow meter (requires flow meter) Note: Values Default: 0 Range: 0 to 4 P2-02 (0C65) Sleep Level Sleep Level P2-03 (0C66) Sleep Delay Time Sleep Delay Time Sets the delay time before the drive enters Sleep Mode when the Default: 0 s sleep level set in P2-02 is reached. Min.: 0 Max.: 3600 Sleep Act. Level Sets the level above which the output frequency must rise to Default: 0.0 Hz activate the sleep function when P2-01, Sleep Level Type, is set <2> to 0 (Output Frequency / Speed). Setting this parameter to 0.0 disables the function and the sleep Min.: 0.0 Max.: 6000.0 function will activate when P2-02, Sleep Level, is reached. Sleep Activate Level P2-05 (0C68) Sleep Boost Level P2-06 (0C69) Sleep Boost Hold Time SleepBoost HldTm Sleep Boost Lvl P2-07 (0C6A) Sleep Boost Maximum SleepBoost MaxTm Time P2-08 (0C6B) Delta Sleep Feedback Drop Level D Fb Drop Level P2-09 (0C6C) Feedback Detection Drop Time FB Drop Det. Time 167 Feedback depends on PID direction operation. Sleep activates when the selected level type (P2-01 setting) reaches the programmed sleep level for the time set in P2-03. Default: 0.0 Hz This function is active when the drive is running during AUTO <1> Mode. When P1-01 is set to 3 (MEMOBUS network), the function is active when there is only one drive running on the Min.: 0.0 Max.: 6000.0 network. Setting this parameter to 0.0 disables the function. P2-04 (0C67) Page Sets the amount of boost applied to the setpoint before going to Default: 0.0 PSI <3> sleep. Setting this parameter to 0.0 disables the function. Min.: 0.0 Max.: 6000.0 Sets the amount of time that the boosted pressure will be Default: 5.0 s maintained before the drive goes to sleep. Min.: 0.5 Max.: 160.0 Sets the amount of time that the system (feedback) has to reach Default: 20.0 s the boosted setpoint. The drive will go to sleep when the amount Min.: 1.0 of time set in this parameter has been exceeded. Max.: 160.0 If the PID Error (setpoint minus feedback) exceeds the level programmed in this parameter within the time window set in P2-09 and the output frequency is greater than the level set in P1-06, the sleep operation deactivates and the drive returns to normal operation. Setting this parameter to 0.0 disables the function. Defines the time window in which the software monitors the feedback to detect a flow/no-flow condition. 167 167 – – – – Default: 0.0 PSI <3> Min.: 0.0 Max.: 6000.0 Default: 10.0 s Min.: 0.0 Max.: 3600.0 – – Parameter List No. (Addr. Hex) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 303 B.11 P: Pump Parameters No. (Addr. Hex) Name P2-10 (0C6D) Sleep Mode: Cycling Protection LCD Display Cycle Protection P2-11 Sleep Mode: Maximum (0C6E) Cycling Protection Max. Cycle Time Time P2-12 (0C6F) Over Cycling Mode Over Cycle Mode 0: Disabled 1: Alarm Only 2: Fault 3: Auto SP Comp. P2-13 (0C70) Setpoint Compensation Setpoint Comp. P2-14 (0C71) Maximum Setpoint Compensation Max. SP Comp. Description Sets the maximum number of cycles that are allowed within the time specified in P2-11 before tripping the PoC “Pump Over Cycle” fault. One cycle is defined when the drive transfers from normal operation in AUTO Mode to Sleep Mode. This function is active when the drive is running during AUTO Mode. When P1-01 is set to 3 (MEMOBUS network), the function is active when there is only one drive running on the network. Setting this parameter to 0 disables the function. Sets the maximum time allowed between cycles. When no cycling occurs within the programmed time, the drive will decrease the internal cycle register. Values Page Default: 0 Min.: 0 Max.: 10 – Default: 300 s Min.: 0 Max.: 3600 – 0: Disabled 1: Alarm 2: Fault 3: Auto SP Compensation Default: 0 Range: 0 to 3 – Allows for the software to automatically compensate the setpoint in the event of excessive cycling. Default: 0.0 PSI <3> Min.: 0.0 Max.: 6000.0 Sets the maximum allowed setpoint compensation for overcycling function. – Default: 0.0 PSI <3> Min.: 0.0 Max.: 6000.0 Sets the amount of PI error bandwidth used to detect the AntiDefault: 0.40% No-Flow condition. Avoid setting this parameter value too high, as operation may Min.: 0.00 Max.: 2.00 become unstable. Setting this parameter to 0.00 will disable the function. P2-23 (0C7A) Anti-No-Flow Bandwidth ANF Bandwidth P2-24 (0C7B) Anti-No-Flow Detection Time ANF Det. Time Sets the time delay before the drive starts the increased deceleration rate after Anti-No-Flow is detected. Default: 10.0 s Min.: 1.0 Max.: 60.0 P2-25 (0C7C) Anti-No-Flow Release Level Sets the amount below the setpoint which the feedback must drop to disengage the Anti-No-Flow and return to normal PI operation. Default: 3.0 PSI ANF Release Lvl <3> Min.: 0.0 Max.: 100.0 – – – – <1> Display units vary depending on the setting for P2-01, Sleep Level Type. When P2-01 is set to 0, the display units are “Hz”; setting 1 is “A”; setting 2 is P1-02 Selection; setting 3 is “RPM”; setting 4 is P6-04 selection. <2> Display units vary depending on the setting for P2-01, Sleep Level Type. When P2-01 is set to 0, 1, 2, or 4, the display units are “Hz”; setting 3 is “RPM”. <3> Unit is determined by P1-02, Ssytem Units, setting. u P3: Contactor Multiplexing No. (Addr. Hex) Name LCD Display P3-00 (0CC7) Number of Lag Pumps Num of Lag Pumps P3-01 (0CC8) Add Pump Control Add Pump Control 0: Output Frequency 1: Feedback 2: Feedback + Fout P3-02 Shutdown Pump (0CC9) Control Shutdown Pump Ctl 0: Output Frequency 1: Feedback 2: Feedback + Fout 304 Description Sets the number of lag pumps present. Selects the method for adding contactor pumps to the system. 0: Output frequency (Uses P3-03 and P3-05) 1: Feedback (Uses P3-04 and P3-05) 2: Feedback + Fout (Uses P3-03, P3-04, and P3-05) Selects the method for removing contactor pumps from the system. 0: Output frequency (Uses P3-09, P3-50 P3-60, P3-70, P3-80, and P3-90) 1: Feedback (Uses P3-08 and P3-09) 2: Feedback + Fout (Uses P3-08, P3-09, P3-50, P3-60, P3-70, P3-80, and P3-90) Values Default: 1 Min.: 1 Max.: 5 Page 167 Default: 0 Range: 0 to 2 – Default: 0 Range: 0 to 2 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.11 P: Pump Parameters Name LCD Display P3-03 (0CCA) Drive Multi/Maximum Max-Multi Level Level P3-04 (0CCB) Add Pump Delta Level Add Pump D-Lvl Description Sets the maximum level used for the multiplex pumping operation. Parameter is active only when P3-01 is set to 0 or 2. When P3-01 is set to 0, the next available pump will be added to the system by a multi-function Discrete Output closure (H2-0o = 80 to 84) when the output frequency rises above the Default: 59.0 Hz level set in this parameter for the time set in P3-05. Min.: 0.0 When P3-01 is set to 2, the next available pump will be added Max.: 400.0 to the system by a multi-function Discrete Output closure (H2-0o = 80 to 84) when the output frequency rises above the level set in this parameter and the delta feedback (setpoint minus feedback) has exceeded the level programmed in P3-04 for the time set in P3-05. Sets the level used for the multiplex pumping operation. Parameter is active only when P3-01 is set to 1 or 2. When P3-01 is set to 1, the next available pump will be added to the system by a multi-function Discrete Output closure (H2-0o = 80 to 84) when the delta feedback (setpoint minus feedback) has exceeded the level set in this parameter for the time set in P3-05. Default: 0.0 PSI When P3-01 is set to 2, the next available pump will be added <1> to the system by a multi-function Discrete Output closure Min.: 0.0 (H2-0o = 80 to 84) when the output frequency rises above the Max.: 6000.0 level set in P3-03 and the delta feedback (setpoint minus feedback) has exceeded the level set in this parameter for the time set in P3-05. Note: P3-05 (0CCC) Add Pump Delay Time Add Pump Dly Tm P3-06 (0CCD) Frequency Reduction after Staging P3-07 (0CCE) Frequency Reduction after Staging Time P3-08 (0CCF) Shutdown Pump Delta Level Values Page – – Programming this parameter too close to the system setpoint may cause the pump system to cycle excessively. Sets the delay time before a pump is added to the system. Default: 2 s Min.: 0 Max.: 3600 – FreqReduce@Stage Sets the upper limit of the output frequency after a lag pump is Default: 0.0 Hz staged. Min.: 0.0 The upper limit of the output frequency is calculated by subtracting the value of this parameter from parameter P3-03. Max.: 30.0 Output limit = P3-03 - P3-06 – FreqReduce Time Sets the amount of time that the output frequency will be limited Default: 0.0 s after lag pump is staged. Min.: 0.0 Max.: 240.0 – Shdn Pump D-Lvl Sets the level used for the multiplex pumping operation. Parameter is active only when P3-02 is set to 1 or 2. When P3-02 is set to 1, the last pump that was brought online will be shut down by opening the dedicated mult-function discrete output (H2-0o = 80 to 84) when the delta feedback (feedback minus setpoint) has exceeded the level programmed in this parameter for the time set in P3-09. When the P3-02 is set to 2, the last pump that was brought online Default: 0.0 PSI <1> will be shut down by opening the dedicated multi-function discrete output (H2-0o = 80 to 84) when the output frequency Min.: 0.0 Max.: 6000.0 drops below the level programmed in P3-50, P3-60, P3-70, P3-80, or P3-90 and the delta feedback (feedback minus setpoint) has exceeded the level set in this parameter for the time set in P3-09. Note: Programming this parameter too close to the system setpoint may cause the pump system to cycle excessively. P3-09 (0CD0) Shutdown Pump Delay Shdn Pump Dly Tm Time Sets the delay time before one of the additional line pumps is shut down. Default: 5 s Min.: 0 Max.: 3600 P3-10 (0CD1) Setpoint Boost Maximum at De-Stage Sets the maximum amount of boost that can be added to the setpoint after a de-stage occurs. Setting this parameter to 0.0 disables the function. Default: 0.0 PSI MaxBoost@DeStage – <1> Min.: -20.0 Max.: 20.0 – – Parameter List No. (Addr. Hex) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 305 B.11 P: Pump Parameters No. Name LCD Display (Addr. Hex) P3-11 (0CD2) Setpoint Boost after De- SP Boost Time Stage Time P3-12 Multi Pump Setpoint (0CD3) Increase during Transition P3-13 Multi Pump Setpoint (0CD4) Decrease during Transition MP Setpoint Inc MP Setpoint Dec P3-14 (0CD5) Multiplex Stabilization M-Stabilize Time Time Description Values Sets the amount of time that the setpoint will remain boosted after lag pump is de-staged. Default: 5.0 s Min.: 0.0 Max.: 60.0 Sets the system setpoint increase each time a new pump is brought online. Pump 1: Setpoint Pump 1 + 2: Setpoint + P3-12 Pump 1 + 2 + 3: Setpoint + 2 x P3-12 Sets the system setpoint decrease each time a new pump is brought online. Pump 1: Setpoint Pump 1 + 2: Setpoint - P3-13 Pump 1 + 2 + 3: Setpoint - 2 x P3-13 Sets the time used to stabilize the system when a pump is added or shut down during multiplex operation. When a pump is added, the stabilize timer temporarily disables the lead/lag functionality for the programmed time to prevent pump cycling. Function is active in contactor multiplex mode (P1-01 = 1). Time pump protection and lead/lag control is suspended during stabilization time. Default: 0.0 PSI <1> Min.: 0.0 Max.: 6000.0 Page – – Default: 0.0 PSI <1> Min.: 0.0 Max.: 6000.0 – Default: 2 s Min.: 0 Max.: 3600 – P3-30 (0CD5) Stage Selection Mode Stage Sel Mode 0: Sequential 1: Stop History Sets the method of staging for the pumps. 0: Sequential 1: Stop history Default: 0 Range: 0, 1 – P3-31 De-Stage Selection (0CE6) Mode Destage Sel Mode 0: LastInFirstOut 1: FirstInFirstOut Sets the method for removing contactor pumps. 0: Last in, first out (LIFO) 1: First in, first out (FIFO) Default: 0 Range: 0, 1 – P3-40 Pre-Charge Lag Pump (0CEF) Select Precharge LagSel 0: Disabled 2: Pump2 (H2-0X=80) 3: Pump3 (H2-0X=81) 4: Pump4 (H2-0X=82) 5: Pump5 (H2-0X=83) 6: Pump6 (H2-0X=84) Default: 0 Range: 0; 2 to 6 – P3-41 (0CF0) Pre-Charge Lag Pump Run Time Precharge Lag Tm Selects which of the lag pumps can come on during a pre-charge. 0: Disabled 2: Pump 2 (H2-0o = 80) 3: Pump 3 (H2-0o = 81) 4: Pump 4 (H2-0o = 82) 5: Pump 5 (H2-0o = 83) 6: Pump 6 (H2-0o = 84) Sets the length of time that the lag pump specified in P3-40 is energized. Default: 0.0 min Min.: 0.0 Max.: 3600.0 – P3-42 (0CF1) Post-Pre-Charge Lag Pump Operation Time Post PreChg Lag 0: Turn Off 1: Continue Default: 0 Range: 0, 1 – P3-43 (0CF2) Pre-Charge Lag Pump Delay Time PreChg Lag Delay Pump 2 Frequency Shutdown Level P2 Shutdown Freq Pump 3 Frequency Shutdown Level P3 Shutdown Freq Pump 4 Frequency Shutdown Level P4 Shutdown Freq P3-50 (0CF9) P3-60 (11E5) P3-70 (11EF) 306 Determines whether the lag pump set in pre-charge (P3-40) turns off or maintains its state when pre-charge is completed. 0: Turn off 1: Continue Sets the length of time that the drive is in the pre-charge mode Default: 2.0 min before the lag pump set in P3-40 is energized. Min.: 0.0 Max.: 600.0 Sets the level used for the multiplex pumping operation. Parameter is active only when P3-02 is set to 0 or 2. When P3-02 is set to 0 and a total of two pumps are running, the last pump (Pump 2) that was brought online will be shut down by opening the dedicated mult-function discrete output (H2-0o = 80 to 84) when the output frequency falls below the Default: 40.0 Hz level set in this parameter for the time set in P3-09. Min.: 0.0 When P3-02 is set to 2 and a total of two pumps are running, the Max.: 400.0 last pump (Pump 2) that was brought online will be shut down by opening the dedicated mult-function discrete output (H2-0o = 80 to 84) when the delta feedback (setpoint minus feedback) has exceeded the level programmed in this parameter for the time set in P3-09. Sets the level used for the multiplex pumping operation. Parameter is active only when P3-02 is set to 0 or 2. Parameter function is similar to P3-50, except for Pump 3 instead of Pump 2. Sets the level used for the multiplex pumping operation. Parameter is active only when P3-02 is set to 0 or 2. Parameter function is similar to P3-50, except for Pump 4 instead of Pump 2. – 167 Default: 40.0 Hz Min.: 0.0 Max.: 400.0 167 Default: 40.0 Hz Min.: 0.0 Max.: 400.0 168 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.11 P: Pump Parameters No. (Addr. Hex) P3-80 (11F9) P3-90 (1203) Name LCD Display Pump 5 Frequency Shutdown Level P5 Shutdown Freq Pump 6 Frequency Shutdown Level P6 Shutdown Freq Description Sets the level used for the multiplex pumping operation. Parameter is active only when P3-02 is set to 0 or 2. Parameter function is similar to P3-50, except for Pump 5 instead of Pump 2. Sets the level used for the multiplex pumping operation. Parameter is active only when P3-02 is set to 0 or 2. Parameter function is similar to P3-50, except for Pump 6 instead of Pump 2. Values Page Default: 40.0 Hz Min.: 0.0 Max.: 400.0 – Default: 40.0 Hz Min.: 0.0 Max.: 400.0 – Values Page <1> Unit is determined by P1-02, Ssytem Units, setting. u P4: Pump Advanced Name LCD Display P4-01 (0CFA) Pre-Charge Level Pre-Charge Level P4-02 (0CFB) Pre-Charge Frequency Pre-Charge Freq. P4-03 (0CFC) Pre-Charge Time Pre-Charge Time P4-05 (0CFE) Pre-Charge Loss of Prime Level Pre-Charge LOP P4-06 (0CFF) Pre-Charge Frequency 2 Pre-Charge Freq2 P4-07 (0D01) P4-08 (0D01) P4-10 (0D03) P4-11 (0D04) P4-12 (0D05) Pre-Charge Time 2 Pre-Charge Loss of Prime Level 2 Pre-Charge Time2 Pre-Charge LOP 2 AUTO Mode Operator AMO PwDn-Storage Run Power Down 0: Disabled Storage 1: Enabled Thrust Bearing Acceleration Time Thrust Bearing Frequency Thrust Acc. Time Thrust Freq. Description Runs the drive at the frequency set in P4-02. The drive will stop when one of the following conditions occurs: • The feedback level rises above the level set in P4-01 • The pre-charge time set in P4-03 expires • The low water digital input is deactivated (#8F) Sets the frequency reference used when the Pre-Charge function is active. Default: 0.0 PSI <1> Min.: 0.0 Max.: 6000.0 168 Default: 0.0 Hz Min.: 0.0 Max.: [E1-04] 168 Default: 0.0 min Min.: 0.0 Max.: 3600.0 168 Sets the maximum allowed Pre-Charge time. When P1-01 is set to 3 (MEMOBUS network), the function is active only on the first drive to run in the network. Setting this parameter to 0.0 disables the function. Detects loss of prime in the pump. When the measured quantity determined by P1-18 drops below this level for the time set in P1-20 and the output frequency is at the level set in P4-02, a “Loss of Prime” condition occurs. The drive responds to the “Loss of Prime” condition depending on the setting of P1-22, Loss of Prime Selection. Sets the frequency reference used when the Pre-Charge function 2 is active. Setting this parameter to 0.0 disables the function. Default: 0.0 Hz Min.: 0.0 Max.: [E1-04] – Sets the time at which the drive will spend at the Pre-Charge frequency 2 speed during pre-charge. Setting this parameter to 0.0 disables the function. Default: 0.0 min Min.: 0.0 Max.: 3600.0 – Detects loss of prime in the pump. When the measured quantity determined by P1-18 drops below this level for the time set in P1-20 and the output frequency is at the level set in P4-06, a “Loss of Prime” condition occurs. The drive responds to the “Loss of Prime” condition depending on the setting of P1-22, Loss of Prime Selection. Stores the run status in AUTO Mode when operating from the HOA keypad (b1-02 = 0). 0: Disabled 1: Enabled Sets the time at which the drive output frequency will ramp up to the reference frequency set in P4-12. Default: 0.0 A <2> Min.: 0.0 Max.: 1000.0 – Default: 0.0 A <2> Min.: 0.0 Max.: 1000.0 Default: 0 Range: 0, 1 Default: 1.0 s Min.: 0.0 Max.: 600.0 The drive will accelerate to this frequency in the time set to P4-11. The drive will decelerate from the frequency in the time set to P4-13. Default: 30.0 Hz Min.: 0.0 WARNING! Sudden Movement Hazard. If the drive is Max.: [E1-04] powered down while running, it will automatically initiate an internal Run command upon power-up. – 168 – 168 Parameter List No. (Addr. Hex) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 307 B.11 P: Pump Parameters No. (Addr. Hex) P4-13 (0D06) Name Thrust Bearing Deceleration Time LCD Display Thrust Dec Time P4-17 (0D0A) Utility Start Delay Utility Delay P4-21 (0D0E) Low City Input Select Low City In Sel 0: Normally Open 1: Normally Closed P4-22 (0D0F) Low City On-Delay Time Low City On Dly P4-23 (0D10) Low City Off-Delay Time Low City Off Dly P4-24 (0D11) Low City Alarm Text Low City Alarm Txt 0: Low Cty Pressure 1: Low Suction Pres 2: Low Watr in Tank P4-25 (0D12) Remote Drive Disable Selection Rem Drv Dis Sel 0: Normally Open 1: Normally Closed Remote Drive Disable On-Delay Drv Dis On-Delay Remote Drive Disable Off-Delay P4-26 (0D13) P4-27 (0D14) P4-31 (0D18) Lube Pump Delay Timer Description Sets the amount of time it takes to bring the drive from the Thrust Frequency set in P4-12 to stop when Thrust Mode is active. When the Run command is removed while the drive is operating in Thrust Mode above the Thrust Frequency, the time set in this parameter is used when the frequency reference is at or below the thrust frequency. Sets the amount of time that the drive will delay starting if a Run command is present at power-up. When P1-01, Pump Mode, is set to 3 (MEMOBUS network), the drive is unavailable to the network (Pump Off Network) when the function is active. Setting this parameter to 0.0 disables the function. Selects the type of pressure switch connected to the “Low City Press” digital input (H1-0o = 73). 0: Normally open (closed indicates the Low City Pressure condition) 1: Normally closed (open indicates the Low City Pressure condition) Sets the amount of time a Low City Pressure condition needs to be present before the drive will stop. Values Default: 5.0 s Min.: 0.0 Max.: 600.0 Default: 0.2 min Min.: 0.0 Max.: 1000.0 – 168 Default: 1 Range: 0, 1 – Default: 10 s Min.: 1 Max.: 1000 – Sets the amount of time a Low City Pressure condition needs to Default: 5 s be absent before the drive will restart. Min.: 0 Max.: 1000 Selects the alarm message that will be displayed when a Low City Pressure condition is detected. 0: Low city pressure 1: Low suction pressure 2: Low water in tank Selects the type of pressure switch connected to the “Remote Drive Disable” digital input (H1-0o = 95). 0: Normally open (closed indicates the Remote Drive Disable condition) 1: Normally closed (open indicates the Remote Drive Disable condition) Sets the amount of time a Remote Drive Disable condition must be present before the drive will stop. Page – Default: 0 Range: 0 to 2 – Default: 1 Range: 0, 1 – Default: 0 s Min.: 0 Max.: 1000 – Drv Dis OffDelay Sets the amount of time a Remote Drive Disable condition must Default: 0 s be absent before the drive will run. Min.: 0 Max.: 1000 – Lube Pump Time Sets the amount of time to delay the drive output and to energize Default: 0.0 s the Lube Pump digital output (H2-oo = 8B) before the drive Min.: 0.0 is allowed to run. Max.: 300.0 Setting this parameter to 0.0 disables the function. – <1> Unit is determined by P1-02, Ssytem Units, setting. <2> Unit text is set by P1-18, Prime Loss Detection Method. u P5: Pump HAND Mode No. Name (Addr. Hex) P5-01 (0D2C) HAND Mode Ref Source P5-02 (0D2D) HAND Reference 1 308 LCD Display Description Values Hand Mode Ref. 0: Analog Input 1: Hand Ref 1 (OPR) Sets the HAND Mode reference. 0: Analog input A1 (0-10 V) 1: P5-02 (HAND reference) HAND Reference 1 Sets the frequency reference used when HAND Mode is active Default: 40.0 Hz and P5-01 is set to 1. Min.: 0 Max.: [E1-04] Default: 1 Range: 0, 1 Page – 169 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.11 P: Pump Parameters No. (Addr. Hex) Name P5-03 HAND/AUTO During (0D2E) Run Selection P5-04 HAND Key Function (0D2F) Selection P5-05 (0D30) P5-06 (0D31) P5-07 (0D32) P5-09 (0D34) HAND Reference 2 HAND Ref. 1 Loss of Prime Level HAND Ref. 2 Loss of Prime Level LCD Display Description HAND/AUTO @ Run Selects whether the drive will permit switching between HAND and AUTO Modes while running. 0: Disabled 0: Disabled 1: Enabled 1: Enabled Oper HAND Key Enables and disables the HAND key on the HOA keypad. 0: Disabled 0: Disabled 1: Enabled 1: Enabled Sets the frequency reference used when HAND Mode 2 is active. HAND Reference 2 Values Page Default: 0 Range: 0, 1 – Default: 1 Range: 0, 1 169 Default: 0.0 Hz Min.: 0 Max.: [E1-04] – HandRef1 LOP Lvl Detects loss of prime in the pump. When the measured quantity determined by P1-18 drops below Default: 0.0 PSI this level for the time set in P1-20 and the output frequency is <1> at the level set in P5-02, a “Loss of Prime” condition occurs. Min.: 0.0 The drive responds to the “Loss of Prime” condition depending Max.: 1000.0 on the setting of P1-22, Loss of Prime Selection. – HandRef2 LOP Lvl Detects loss of prime in the pump. When the measured quantity determined by P1-18 drops below Default: 0.0 PSI this level for the time set in P1-20 and the output frequency is <1> at the level set in P5-05, a “Loss of Prime” condition occurs. Min.: 0.0 The drive responds to the “Loss of Prime” condition depending Max.: 1000.0 on the setting of P1-22, Loss of Prime Selection. – Selects whether parameters P5-02 and P5-05 are changed via MOP from the home screen. 0: Disabled 1: Enabled – HAND References Set HAND MOP Sel via Motor Operated Pot 0: Disabled Selection 1: Enabled Default: 0 Range: 0, 1 <1> Unit text is set by P1-18, Prime Loss Detection Method. u P6: Flow Meter Setup Name LCD Display P6-01 (0D5E) Flow Meter Scaling Flow Meter Scale P6-02 (0D5F) Turbine Input Scaling (Course) Turbine Scale 1 P6-03 (0D60) Turbine Scale 2 Turbine Input Scaling (Fine) Description When an analog input is used for the flow rate, this parameter performs the following functions: • Enables and disables flow meter functions. This parameter must be set to a value greater than 0 to enable flow meter functions. • Sets the scaling for the “Flow Rate” analog input. • Sets the scaling for the “Flow Rate” analog output. • Sets the display scaling when “Flow Rate” is used as the PID feedback. When an pulse input is used for the flow rate, this parameter performs the following functions: • Enables and disables flow meter functions. Parameter must be set to a value greater than zero to enable flow meter functions. • Sets the scaling for the “Flow Rate” analog output. • Sets the display scaling when “Flow Rate” is used as the PID feedback. Sets the scaling for the turbine in pulses per gallon. Pulses/Gallon = P6-02 + P6-03 This parameter is internally lower-limited to 0.0001 ppG. Values Page Default: 0.0 GPM Min.: 0.0 Max.: 6000.0 – Default: 1 ppG Min.: 0 Max.: 6000 – Default: 0.0000 ppG Min.: 0.0000 Max.: 0.9999 – Parameter List No. (Addr. Hex) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 309 B.11 P: Pump Parameters No. (Addr. Hex) P6-04 (0D61) P6-05 (0D62) Name LCD Display Water Flow Units Water Flow Units 0: Gal/Min (GPM) 1: Gal/Hr (GPH) 2: Ft3/Min (CFM) 3: M3/Hr (CMH) 4: Acre-Ft/Yr (AFY) Flow Accumulation Reset Flow Accum Reset Description Sets the display units for monitor U1-83, P2-02, P6-06, P6-17, P9-41, and P9-42. 0: U.S. Gallons / min (GPM) 1: U.S. Gallons / hr (GPH) 2: Cubic Feet / min (CFM) 3: Cubic Meters / hr (CMH) 4: Acre-Feet / yr (AFY) Resets the accumulated flow and returns monitors U1-96 and U1-97 to 0. 0: No reset 7770: Reset accumulation All other settings have no effect. Values Page Default: 0 Range: 0 to 4 – Default: 0 Min.: 0 Max.: 65535 – Note: P6-06 (0D63) After this parameter is changed, the setting will automatically return to “0”. Sets the level below which the flow must fall for longer than the Default: 0.0 time set in P6-07 to trigger a Low Flow condition. GPM <1> Setting this parameter to 0.0 will disable the function. Min.: 0.0 Max.: 6000.0 Low Flow Level Low Flow Level Low Flow Detection Delay Time When Already Running Low Flow Tim Run Sets the length of time that the flow rate must be below the level Default: 10 s set in P6-06 to detect a Low Flow condition. Min.: 0 Max.: 6000 – Low Flow Detection Wait Time at Start Low Flow Time St Sets the length of time that the drive will wait after coming out Default: 0.0 min of a zero speed condition before activating Low Flow detection. Min.: 0.0 Max.: 3600.0 – P6-09 (0D66) Low Flow Select Low Flow Sel 0: No Display 1: Alarm Only 2: Fault 3: Restart (P6-10) Determines drive response when a Low Flow condition is detected. 0: No display 1: Alarm only 2: Fault 3: Auto-restart (time set by P6-10) – P6-10 (0D67) Low Flow Auto-Restart LowFlow Restart Time P6-07 (0D64) P6-08 (0D65) P6-11 (0D68) P6-12 (0D69) Accumulation Level Millions AccumLvl*1000000 Accumulation Level Thousands AccumLvl*1000 P6-13 (0D6A) Accumulation Level Ones P6-14 (0D6B) Accumulation Level Decimal Set the length of time that the drive will wait before attempting Default: 3.0 min an auto-restart of the Low Flow fault. Min.: 0.1 This parameter is effective only when P6-09 is set to 3. Max.: 6000.0 Sets the accumulated volume that will trigger the Accum Level Default: 0 gal <2> alarm, Accum Level fault, or the Accum Level digital output. Min.: 0 Accum Level is calculated using the following formula: Max.: 65535 Level = (P6-11 * 1000000) + (P6-12 * 1000) + P6-13 + P6-14) Default: 0 gal <2> Min.: 0 Max.: 999 – – – AccumLvl*1 Default: 0 gal <2> Min.: 0 Max.: 999 – AccumLvl*0.0001 Default: 0.0000 gal <2> Min.: 0.0000 Max.: 0.9999 – Default: 1 Range: 0 to 3 – Default: 1 Range: 1, 2 – Accum Behavior P6-15 0: No Display (0D6C) Accumulation Behavior 1: Alarm Only 2: Fault 3: Fault-ResetAccum P6-16 Flow Meter Units (0D6D) Accumulator Select Accum Units 1: Gallons (gal) 2: Acre-Feet (A-F) P6-17 (0D6E) High Flow Level High Flow Level 310 Default: 1 Range: 0 to 3 – Determines drive response when the accumulated volume reaches the P6-11 to P6-14 level. 0: No display 1: Alarm only 2: Fault 3: Fault - Auto flow accum reset Selects whether the drive accumulates flow in gallons or acrefeet. 1: Gallons (gal) 2: Acre-feet Note: Changing this parameter resets the accumulated flow (U1-84 to U1-87) to zero. Sets the level above which the flow must rise for the time set in Default: 0.0 P6-18 to trigger a High Flow condition. GPM <1> Min.: 0.0 Max.: 6000.0 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.11 P: Pump Parameters No. Name (Addr. Hex) P6-18 (0D6F) High Flow Detection Delay Time P6-19 (0D70) High Flow Select LCD Display Description Values Page High Flow Time Sets the length of time that the flow rate must be above the level Default: 10 s set in P6-17 to detect a High Flow condition. Min.: 1 Max.: 6000 – High Flow Sel 0: No Display 1: Alarm Only 2: Fault 3: Restart (L5-04) Sets drive behavior when a High Flow condition is detected. 0: No display 1: Alarm only 2: Fault 3: Auto-restart (time set by L5-04) – Default: 1 Range: 0 to 3 <1> Unit text is set by P6-04, Water Flow Units. <2> Unit text is set by P6-16, Flow Meter Accumulator Units Select. u P7: Anti-Jam No. (Addr. Hex) Name LCD Display Description Values Page P7-01 (0D90) Anti-Jam Operation Selection Anti-Jam Sel 0: Disabled 1: Enabled Enables and disables the anti-jam function. 0: Disabled 1: Enabled Default: 0 Range: 0, 1 – P7-02 (0D91) Anti-Jam Cycle Count AJ Cycle Count Sets the maximum number of cycles that will be attempted before triggering and Anti-Jam fault. Default: 1 Min.: 1 Max.: 100 – Anti-Jam Detection Current Level AJ Det I @Start Sets the current level at start that will trigger the anti-jam function. Set as a percentage of the motor rated current. Default: 120% Min.: 50 Max.: 200 – Anti-Jam Detection Time at Start AJ Det Tm@Start Sets the length of time that current must rise above the level set Default: 0.3 s in P7-03 to trigger the anti-jam function. Min.: 0.1 Max.: 2.0 – Anti-Jam During Run Current AJ Det I @Run Sets the current level during run that will trigger the anti-jam function. Set as a percentage of motor rated current. Setting this parameter to 0 will disable anti-jam during run. – Anti-Jam During Run Time AJ Det Tm @Run Sets the length of time that the current must rise above the level Default: 0.3 s set in P7-05 to trigger the anti-jam function. Min.: 0.1 Restricted to simplex only. Max.: 2.0 Anti-Jam Frequency Reference AJ Freq Ref P7-03 (0D92) P7-04 (0D93) P7-05 (0D94) P7-06 (0D95) P7-07 (0D96) P7-08 (0D98) Anti-Jam Release Time AJ Release Time Default: 0% Min.: 0 Max.: 200 Sets the maximum speed allowed when the anti-jam function is Default: 25.00 active. Hz Min.: 0.00 Max.: 400.00 Sets the length of time that the current must fall below the level Default: 2.0 s set in P7-03 to resume normal operation. Min.: 0.5 Max.: 10.0 – – – u P9: Network Options Parameters in this group are functional only when P1-01, Pump Mode, is set to 3 (MEMOBUS network). Name P9-01 (0DF4) Lead Drive Selection P9-02 (0DF5) Feedback Source LCD Display Lead Drive Sel 0: Next Available 1: Lowest Runtime 2: Stop History Description Specifies how the next lead drive is selected. 0: Next available 1: Lowest runtime 2: Stop history Defines which signal to use for PI feedback when P1-01, Pump Feedback Source Mode, is set to 3 (MEMOBUS network). 0: Analog only 1: Ana->Net, No Alrm 0: Analog only 2: Ana->Net, Alarm 1: Ana->Net, No Alrm 2: Ana->Net, Alarm 3: Network only 3: Network only YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Values Page Default: 1 Range: 0 to 2 – Default: 0 Range: 0 to 3 – Parameter List No. (Addr. Hex) B 311 B.11 P: Pump Parameters No. Name (Addr. Hex) P9-03 (0DF6) Alternation Time LCD Display Alternation Time P9-04 (0DF7) Alternation Mode Alternation Mode 0: FIFO Auto 1: FIFO Forced 2: LIFO 3: FIFO @ Sleep P9-05 (0DF8) Lag Drive Mode Lag Drive Mode 0: Fixed Speed 2: Turn Off 3: Follow Lead Spd P9-06 (0DF9) Lag Fixed Speed Lag Fixed Speed P9-07 (0DFA) Lag Fixed Speed Delay Lag Fix Spd Dly P9-08 (0DFB) Add Pump Mode P9-09 (0DFC) Add Frequency Level – Default: 0 Range: 0 to 3 – Default: 0 Range: 0, 2, 3 – Default: 55.0 Hz Min.: 0.0 Max.: 400.0 – Selects the detection method for staging a new pump. 0: Output frequency 1: Feedback 2: Feedback + Fout 3. Flow meter – Add Freq Lvl When P9-08 is set to 0, this parameter sets the level above which the output frequency needs to rise for the time set in P9-11 before the lead drive will send a request for a new lead drive via the Default: 59.5 Hz iQPump MEMOBUS network. When P9-08 is set to 2 and the delta feedback (setpoint minus Min.: 0.0 feedback) has exceeded the level set in P9-10 for the time set in Max.: 400.0 P9-11, this parameter sets the level above which the output frequency needs to rise before the lead drive will send a request for a new lead drive via the iQPump MEMOBUS network. Add Dly Time 312 Default: 24 H Min.: 0 Max.: 1000 Add Pump Mode 0: Output Frequency 1: Feedback 2: Feedback + Fout 3: Flow Meter P9-11 (0DFE) Add Delay Time Remove Frequency Level Determines how alternation is performed. 0: FIFO auto 1: FIFO forced 2: LIFO 3: FIFO @sleep Determines the functionality of the lag drives. 0: Fixed speed. The drive runs at the P9-06 setting after the time set in P9-07 expires. 2: Turn off. The drive stops running when it switches to a lag drive after the time set in P9-07 expires. 3: Follow Lead Speed. The drive will follow the speed of the current lead drive, applying P9-30 gain and P9-31 bias. Sets the speed at which the drive will run when the drive changes from a lead to a lag and the time set in P9-07 has expired. Page – Add Delta Lvl P9-13 (0E00) Specifies the time for a drive to request alternation. Setting this parameter to 0 disables the function. Values Specifies how long speed is latched before performing the Default: 5 s function specified in P9-05 when the drive changes from a lead Min.: 0 to a lag. Max.: 1000 P9-10 (0DFD) Add Delta Level P9-12 (0DFF) Remove Pump Mode Description Remove Pump Mode 0: Output Frequency 1: Feedback 2: Feedback + Fout 3: Flow Meter Remove Freq Lvl When P9-08 is set to 1, this parameter sets the level above which the delta feedback (setpoint minus feedback) must rise for the time set in P9-11 before the lead drive will send a request for a new lead drive via the iQPump MEMOBUS network. When P9-08 is set to 2 and the output frequency has exceeded the level set in P9-09 for the time set in P9-11, this parameter sets the level above which the delta feedback (setpoint minus feedback) needs to rise before the lead drive will send a request for a new lead drive via the iQPump MEMOBUS network. Sets the delay time before a new lead drive is added to the system. Sets the detection method for de-staging to the previous lead pump. 0: Output frequency 1: Feedback 2: Feedback + Fout 3: Flow meter When P9-12 is set to 0, this parameter sets the level below which the output frequency must fall for the time set in P9-15 before the lead drive will send a request to be removed from the system via the iQPump MEMOBUS network. When P9-12 is set to 2 and the delta feedback (feedback minus setpoint) has exceeded the level set in P9-14 for the time set in P9-15, this parameter sets the level below which the output frequency must fall before the lead drive will request to be removed from the system via the iQPump MEMOBUS network. Default: 0 Range: 0 to 3 – Default: 0.0 PSI <1> Min.: 0.0 Max.: 6000.0 – Default: 10 s Min.: 0 Max.: 3600 – Default: 0 Range: 0 to 3 – Default: 40.0 Hz Min.: 0.0 Max.: 400.0 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.11 P: Pump Parameters No. (Addr. Hex) Name LCD Display P9-14 (0E01) Remove Delta Level Remove Delta Lvl P9-15 (0E02) Remove Delay Time Remove Dly Time Description When P9-12 is set to 1, this parameter sets the level above which the delta feedback (feedback minus setpoint) must rise for the time set in P9-15 before the lead drive will request to be removed from the system via the iQPump MEMOBUS network. When P9-12 is set to 2 and the output frequency has exceeded the level set in P9-13 for the time set in P9-15, this parameter sets the level above which the delta feedback (feedback minus setpoint) frequency must rise before the lead drive will request to be removed from the system via the iQPump MEMOBUS network. Sets the delay time before the lead drive is removed from the system. Values Page Default: 0.0 PSI <1> Min.: 0.0 Max.: 6000.0 Default: 10 s Min.: 0 Max.: 3600 – – Stabilize Time Sets the time used top stabilize the system when a pump is staged Default: 3 s or de-staged. Min.: 0 Lead/lag control and pump protection are suspended during this Max.: 3600 time. – Set-pt Modifier Sets the value by which the system setpoint is incremented depending on the number of pumps that are running. Pump 1: Setpoint Pump 2: Setpoint + ((X-1) (P9-17)) – High Feedback Quick De-Stage High FB De-stage Sets the feedback level that will trigger a quick de-stage. Set as Default: 97.0% a percentage of the P1-09 value. The quick de-stage ignores parameters P9-12 to P9-15 and uses Min.: 0.0 Max.: 100.0 an internal 2 second delay. Setting this parameter to 0.0 disables the feature. – Alternation Unit Alternation Unit 0: Hours (H) 1: Minutes (min) Sets the units used in P9-03. 0: Hours (H) 1: Minutes (min) Default: 0 Range: 0, 1 – P9-20 (0E07) Allow Network Run Allow Net Run 0: Always 1: First/Altrnation 2: First Only 3: Alternation Only Specifies when a network Run command is allowed. 0: Always 1: First/alternation 2: First only 3: Alternation only Default: 0 Range: 0 to 3 – P9-21 (0E08) Run Priority Run Priority Sets the lead drive selection priority overriding the P9-01 selection. If multiple drives have the lowest P9-21 value, then P9-01 determines which drive becomes the lead. Default: 8 Min.: 1 Max.: 16 – Default: 5 Min.: 0 Max.: 10 – Default: 8 Min.: 1 Max.: 8 – Default: 0 s Min.: 0 Max.: 7200 – Default: 8 Min.: 2 Max.: 8 – Default: 4.0 s Min.: 1.0 Max.: 10.0 – Stabilization Time P9-17 (0E04) Setpoint Modifier P9-18 (0E05) P9-19 (0E06) P9-22 (0E09) System Fault Retry P9-23 Maximum Number of (0E0A) Running Pumps System Flt Retry MaxPumps Running P9-24 (0E0B) Lead Swap at Sleep Lead Swap @Sleep P9-25 (0E0C) Highest Node Address Highest Node Adr P9-26 (0E0D) Master Time-out Master Time-out Sets the number of times that the iQPump MEMOBUS network will allow automatic restarts of system faults. The drive uses L5-04, Fault Reset Interval Time, to determine when to attempt a system fault restart. Set this parameter to the same value for all drives on the network. Sets the maximum number of pumps that can run on the system. Sets the length of time for which the lead drive will be in Sleep Mode before this drive will request a swap when there is another drive available with a lower P9-21 setting. Setting this parameter to 0 will disable the function. Sets the highest possible node address in the MEMOBUS network. For optimal network performance, set the serial communication address H5-01 beginning with 01h consecutively up to the last drive and then set this parameter to that H5-01 address. Sets the minimum amount of time that the slave drives will wait for a message from the master before performing the action set in P9-27. Default: 0.0 PSI <1> Min.: -999.9 Max.: 999.9 Parameter List P9-16 (0E03) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 313 B.11 P: Pump Parameters No. (Addr. Hex) Name LCD Display Description Values Page P9-28 (0E0F) Determines the drive response when no messages are received from the master for the time set in P9-26. Network Recovery 0: Automatic. The drive will attempt to assume master 0: Automatic functionality. Network Recovery 1: Slave/Resume 1: Slave/Resume. The drive will continue running when the 2: Slave/Stop master is lost and will wait for a master to come online. 3: Fault MSL 2: Slave/Stop. The drive will stop running when the master is lost and will wait for a master to come online. 3: Fault MSL. Fault the drive with an MSL (Master Lost). Sets the amount of time that the slave drives will wait for a NETSCAN Alarm Time NETSCAN AlrmTime message from the master before displaying a NETSCAN alarm. P9-29 (0E10) Net Start Delay Net Start Delay Sets the amount of time that the network will wait before Default: 2.0 s selecting and starting the lead drive after the first drive on the Min.: 0.0 network has been put on AUTO Mode. Max.: 60.0 – Lag Drive Speed Follower Gain Lag Followr Gain Sets the gain to be applied to the speed of the current lead drive Default: 100.0% when P9-05 is set to 3. The bias to be applied is set in P9-31. Min.: 0.0 Max.: 300.0 – Lag Drive Speed Follower Bias Lag Followr Bias Sets the bias to be applied to the speed of the current lead drive Default: 0.00 Hz when P9-05 is set to 3. The gain to be applied is set in P9-30. Min.: -60.0 Max.: 60.0 – Lag Follower Deceleration Time Lag Followr Dcel Sets the deceleration time when the P9-33 timer is running and Default: 60.0 s the drive is running as Lag Drive Speed Follower (P9-05 is set Min.: 0.0 to 3). Max.: 1000.0 – Lag Follower Deceleration Time Active Time Lag Followr Dtim Sets the time during which the deceleration time set in P9-32 is Default: 0.0 s effective. The drive will use the standard deceleration rate when Min.: 0.0 it expires. Max.: 360.0 Setting this parameter to 0.0 disables the function. – Low Feedback Quick De-Stage Low FB De-stage Sets the low feedback level that will trigger a quick de-stage. The quick de-stage ignores parameters P9-12 and P9-15 and only uses an internal 2 second delay. Setting this parameter to 0.0 disables the function. – P9-40 (0E1B) Flow Rate Source Flow Rate Source 0: Analog Only 3: Network Only Defines the flow meter input source when P1-01, Pump Mode, Default: 0 is set to 3 (MEMOBUS network). Range: 0, 3 0: Analog 3: Network P9-41 (0E1C) Add Flow Level Add Flow Lvl P9-42 (0E1D) Remove Flow Level Remove Flow Lvl P9-50 (0E25) WL/SP Source 0: Analog only 1: Ana->Net, No Alrm 2: Ana->Net, Alarm 3: Network only P9-27 (0E0E) P9-30 (0E11) P9-31 (0E12) P9-32 (0E13) P9-33 (0E14) P9-34 (0E15) 314 Water Level/Suction Pressure Source When P9-08 is set to 3 and the flow rate rises above this level multiplied by the number of pumps running for the time set in P9-11, the lead drive will request for a new lead drive through the iQpump MEMOBUS network. When P9-12 is set to 3 and the flow rate falls below this level multiplied by the number of pumps running - 1 for the time set in P9-15, the lead drive will request to be removed from the system through the iQpump MEMOBUS network. Default: 0 Range: 0 to 3 – Default: 2.0 s Min.: 1.0 Max.: 10.0 – Default: 0.0 PSI <1> Min.: 0.0 Max.: 6000.0 Default: 0.0 GPM Min.: 0.0 Max.: 6000.0 Default: 0.0 GPM Min.: 0.0 Max.: 6000.0 Sets the signal to use for Water Level Control (Q4-oo) or Suction Pressure Control (Q5-oo) when P1-01, Pump Mode, is set to 3 (MEMOBUS network). Default: 0 0: Analog only Range: 0 to 3 1: Ana->Net, No Alrm 2: Ana->Net, Alarm 3: Network only – – – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.11 P: Pump Parameters No. (Addr. Hex) Name LCD Display P9-51 (0E26) Low Water Level/ Low WL Turn-Off Suction Pressure Turn- 0: Disabled Off Method 1: Enabled P9-60 (0E2F) Geothermal Temperature Source P9-99 (0E56) Network Comp Sel Network Compatibility 0: A-Ver: 30034 Selection 1: B-Ver: 30035/36 2: iQ SmartNetwork Geo Temp Source 0: Analog only 1: Ana->Net, No Alrm 2: Ana->Net, Alarm 3: Network only Description Values Page Determines the MEMOBUS multiplex response to Water Level or Suction Pressure. 0: Disabled • Water level does not have an effect on Idle or Lag drives • Water level will not cause alternation 1: Enabled Default: 0 • A drive is considered offline when the Water Level/Suction Range: 0, 1 Pressure is below the wake-up level set in Q4-06/Q5-06. • A Lag drive is removed when the Water Level/Suction Pressure is below the wake-up level set in Q4-06/Q5-06. • A Lead drive is alternated if in Level Control/Suction Pressure while the Water Level is below the septoint set in Q4-03/Q5-03. – 0: Analog only 1: Ana->Net, No Alrm 2: Ana->Net, Alarm 3: Network only Default: 0 Range: 0 to 3 – Determines the communication compatibility for the iQPump MEMOBUS network. 0: A-Ver: 30034 1: B-Ver: 30035/36 2: iQ SmartNetwork Default: 2 Range: 0 to 2 – Parameter List <1> Unit text is set by P1-18, Prime Loss Detection Method. B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 315 B.12 Q: PID Controller Parameters B.12 Q: PID Controller Parameters u Q1: Preset Setpoint No. Name LCD Display (Addr. Hex) Q1-01 (0E58) PID Controller Setpoint Setpoint 1 1 Q1-02 (0E59) Q1-03 (0E59) Q1-04 (0E59) Q1-09 (0E60) PID Controller Setpoint Setpoint 2 2 PID Controller Setpoint Setpoint 3 3 PID Controller Setpoint Setpoint 4 4 PID Setpoint Set via Motor Operated Pot Setpoint MOP 0: Disabled 1: Enabled Description Values Page Default: 0.0 Min.: 0.0 Max.: 6000.0 <1> 169 Sets the PID Setpoint when the “Multi Setpoint 1” multifunction digital input is closed. Default: 0.0 Min.: 0.0 Max.: 6000.0 <1> – Sets the PID Setpoint when the “Multi Setpoint 2” multifunction digital input is closed. Default: 0.0 Min.: 0.0 Max.: 6000.0 <1> – Sets the PID Setpoint when the “Multi Setpoint 1” and “Multi Default: 0.0 Setpoint 2” multi-function digital inputs are closed. Min.: 0.0 Max.: 6000.0 <1> – Selects whether parameters Q1-01 to Q1-04 are changed via MOP from the home screen. 0: Disabled 1: Enabled – Sets the PID Setpoint when b1-01 is set to 0. Default: 0 Range: 0, 1 <1> Unit text is set by P1-02, System Units. Scaling is set by P1-03, Feedback Device Scaling. u Q2: Geothermal Mode Setup No. (Addr. Hex) Name LCD Display Q2-01 Minimum Geothermal (0E8A) Temperature Input MinGeothrm Scale Q2-02 Maximum Geothermal (0E8B) Temperature Input MaxGeothrm Scale Q2-03 (0E8C) Minimum Geothermal Speed MinGeothrm Speed Q2-04 (0E8D) Maximum Geothermal Speed MaxGeothrm Speed Q2-05 (0E8E) Low Temperature to Run at Maximum Geothermal Speed Low Temp @ Max Low Temperature to Run at Minimum Geothermal Speed Low Temp @ Min Q2-07 (0E90) High Temperature to Run at Minimum Geothermal Speed Q2-08 (0E91) High Temperature to Run at Maximum Geothermal Speed Q2-06 (0E8F) Q2-09 (0E92) 316 Geothermal Temperature Loss Detection Description Values Sets the temperature that corresponds to a 0 V (or 4 mA) analog Default: 0.0 °F input. Min.: -110.0 Max.: 320.0 Page – Sets the temperature that corresponds to a 10 V (or 20 mA) analog input. Default: 120.0 °F Min.: -110.0 Max.: 320.0 – Sets the frequency reference characteristics based on the set temperature points and the corresponding frequency. For proper operation, set the parameters as follows: Q2-04 > Q2-03 and Q2-08, Q2-08 > Q2-07 > Q2-06 > Q2-05 Default: 40.0 Hz Min.: 0.0 Max.: 400.0 – Default: 60.0 Hz Min.: 0.0 Max.: 400.0 – Default: 55.0 °F Min.: -110.0 Max.: 320.0 – Default: 65.0 °F Min.: -110.0 Max.: 320.0 – High Temp @ Min Default: 75.0 °F Min.: -110.0 Max.: 320.0 – High Temp @ Max Default: 85.0 °F Min.: -110.0 Max.: 320.0 – Frequency Reference (Hz) Q2-04 Q2-03 Q2-05 Q2-06 Q2-07 Temperature °F Geotherm Loss Det 0: Disabled 1: Alarm Only 2: Fault Q2-08 Selects the drive response when the signal from Terminal A2 falls below 3 mA or rises above 21 mA. This parameter is only effective when H3-0o = 2 (4 to 20 mA) Default: 1 and H3-0o = 21 (Geothermal Temperature). Range: 0 to 2 0: Disabled 1: Alarm 2: Fault – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.12 Q: PID Controller Parameters No. Name LCD Display (Addr. Hex) Q2-10 (0E93) Geothermal Sleep Delay Geotherm Slp Dly Time Q2-11 (0E94) Q2-12 (0E95) Geothermal Temperature Delta Wake Level Geotherm Wake Lvl Geothermal Sleep Wake-Up Delay Time Geotherm Wake Dly Description Values Set the length of time that the drive must be running at the speed Default: 30 s set in Q2-03, Minimum Geothermal Speed, before going to Min.: 0 sleep. Max.: 3600 Sets the geothermal temperature that will wake up the drive. The drive will wake up when one of the following conditions is true: Temperature > Q2-07 + Q2-11 OR Temperature < Q2-06 - Q2-11 Setting this parameter to 0.0 will disable Geothermal Sleep Mode. Sets the length of time that the setting of Q2-11, Geothermal Temperature Delta Wake Level, must be met to wake up the drive. Page – Default: 0.0 °F Min.: 0.0 Max.: 50.00 – Default: 5 s Min.: 0 Max.: 3600 – u Q3: Output Current Limit No. (Addr. Hex) Name LCD Display Description Values Page Q3-01 Output Current Limit (0EBC) Select Current Lim Sel 0: Disabled 1: Enabled Enables and disables the output current regulator. 0: Disabled 1: Enabled Q3-02 (0EBD) Current Limit Current Limit Sets the current limit. Value is internally limited to 300% of the Default: 0.0 A drive rated current, n9-01. Min.: 0.0 Max.: 1000.0 – Q3-10 Single Phase Foldback (0EC5) Selection 1-Phase Foldback 0: Disabled 1: Enabled Enables and disables the single phase ripple regulator. 0: Disabled 1: Enabled – Q3-11 Ripple Regulator (0EC6) Setpoint Ripple Reg S.P. Set as a percentage of the maximum amount of ripple allowed Default: 95.0% Min.: 0.0 before triggering an input phase loss fault. Max.: 200.0 Default: 0 Range: 0, 1 Default: 1 Range: 0, 1 – – u Q4: Water Level Control Name Q4-01 (0EEE) Water Level Selection Q4-02 (0EEF) Water Level Scaling LCD Display Water Level Sel 0: Disabled 1: Enabled Description Water Lvl Scale Enables and disables the water level control. 0: Disabled 1: Enabled Sets the full scale (20 mA) output of the pressure transducer that is connected to the analog input terminal programmed for “WaterLvl/Suction” (H3-oo = 23). Water Lvl Setpnt Note: 1 PSI = 2.308 feet of water Sets the amount of water above the sensor to which the drive will attempt to regulate. Values Page Default: 0 Range: 0, 1 – Default: 100 PSI Min.: 5 Max.: 500 – Default: 20.0 ft Min.: 0.0 Max.: 1200.0 – Q4-03 (0EF0) Water Level Setpoint Q4-04 (0EF1) Minimum Water Level Min Water Level Sets the level below which the amount of water must drop for Default: 10.0 ft the time set in Q4-05 to put the drive to sleep. Min.: 0.0 Max.: 1200.0 – Water Level Sleep Delay Time WL Sleep Dly Tm Sets the length of time that the drive will delay after the water Default: 5 s level drops below the level set in Q4-04 before going to sleep. Min.: 0 Max.: 3600 – Q4-06 (0EF3) Wake-Up Water Level Wake-Up Level Sets the level above which the water needs to rise for more than Default: 30.0 ft the time set in Q4-07 for the drive to wake up after being put to Min.: 0.0 sleep via parameter Q4-04, Minimum Water Level. Max.: 1200.0 – Q4-07 (0EF4) Water Level Control Sleep Wake-Up Time WL Wake-up Time Sets the length of time that the water level set in Q4-06 must be Default: 1 s met for the drive to wake up after being put to sleep via Min.: 0 parameter Q4-04, Minimum Water Level. Max.: 3600 – Q4-05 (0EF2) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Parameter List No. (Addr. Hex) B 317 B.12 Q: PID Controller Parameters No. (Addr. Hex) Q4-08 (0EF5) Q4-09 (0EF6) Q4-10 (0EF7) Q4-11 (0EF8) Q4-12 (0EF9) Name LCD Display Level Control Minimum Level Min Spd Speed Description Sets the minimum speed at which the drive will run when the drive is controlling the water level. When the drive is controlling pressure or if this parameter is set less than P1-06 and P4-12, parameters P1-06 and P4-12 will be used as the minimum speed. Sets the level below which the water level must drop for the time set in Q4-10 to trigger the drive response set in Q4-11. Setting this parameter to 0.0 will disable the function. Values Page Default: 0.00 Hz Min.: 0.00 Max.: 400.00 – Default: 0.0 ft Min.: 0.0 Max.: 1200.0 – Low Level Detection Level Low Level Detect Low Level Detection Time Delay Low Lvl Det Tm Sets the length of time that the water level must fall below the Default: 0.0 <1> level set in Q4-09 to trigger the drive response set in Q4-11. Min.: 0.0 Max.: 300.0 – Low Level Behavior Low Lvl Behavior 0: No Display 1: Alarm Only 2: Fault 3: Restart (Q4-12) Selects drive response when the water level drops below the level set in Q4-09 for the time set in Q4-10. 0: No display (digital output only) 1: Alarm only 2: Fault 3: Restart (time set by Q4-12) – Water Level Control Auto-Restart Time WtrLvl Restart Sets the length of time that the drive will wait before attempting Default: 5.0 min an auto-restart of the Low Water Level fault. Min.: 0.1 This parameter is effective only when Q4-11 is set to 3 and Max.: 6000.0 L5-01 is set to a value greater than 0. Sets the proportional gain for the water level control. Default: 1 Range: 0 to 3 – Q4-13 (0EFA) Level Control Proportional Gain Lvl Ctrl P Gain Q4-14 (0EFB) Level Control Integral Time Lvl Ctrl I Time Sets the integral time for the water level control. Setting this parameter to 0.0 disables the water level control integrator. Q4-15 Low Water Level (0EFC) Detection Time Unit Low Lvl Det Unit 0: Minutes (min) 1: Seconds (sec) Determines the time unit for Q4-10, Low Level Detection Time Default: 0 Delay. Range: 0, 1 0: Minutes (min) 1: Seconds (sec) – Level Analog Q4-16 WaterWire-Break (0EFD) Input Detection WL Wire Break 0: No Display 1: Alarm Only 2: Fault Sets the behavior when the analog input selected for water level feedback is programmed to receive a 4-20 mA signal and the Default: 2 signal is lost. Range: 0 to 2 0: No display 1: Alarm only 2: Fault (no retry, coast to stop) – Default: 2.00 Min.: 0.00 Max.: 25.00 – Default: 5.0 s Min.: 0.0 Max.: 360.0 – <1> Units are determined by Q4-15, Low Water Level Detection Time Unit, setting. u Q5: Suction Pressure Control No. (Addr. Hex) Q5-01 (0F20) Q5-02 (0F21) Q5-03 (0F22) Q5-04 (0F23) 318 Name LCD Display Suction Pres Sel Disabled Suction Pressure Select 0: 1: Suction Pressure 2: Vacuum ("Hg) Suction Transducer Scaling Suction Scaling Suction Pressure Setpoint Suction Setpoint Minimum Suction Pressure Min Suction Pres Description Values Sets the method of operation for the Suction Control / Vacuum Control function. Default: 0 0: Disabled Range: 0 to 2 1: Suction pressure (PSI) 2: Vacuum ("Hg) 100.0 Sets the full scale (20 mA) output of the pressure transducer that Default: <1> is connected to the analog input terminal programmed for Min.: 5.0 “WaterLvl/Suction” (H3-0o = 23). Max.: 1200.0 Sets the amount of suction pressure to which the drive will Default: 20.0 <1> attempt to regulate. Min.: 0.0 Max.: 1200.0 Sets the level below which the suction pressure must fall for Default: 10.0 <1> longer than the Q5-05 time to put the drive to sleep and turn off Min.: 0.0 all lag pumps. Max.: 1200.0 Page – – 169 – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.12 Q: PID Controller Parameters Q5-06 (0F25) Wake-Up Suction Pressure Wake-Up Pres Default: 0.0 <1> Min.: 0.0 Max.: 1200.0 169 Low Pres Det Tm Sets the length of time that the suction pressure must fall below <2> the level set in Q5-09 to trigger a drive response according to Default: 0.1 Min.: 0.0 Q5-11, Low Suction Pressure Behavior Select. Max.: 300.0 Time unit is defined by Q5-18. 170 Low Pressure Sel 0: No Display 1: Alarm Only 2: Fault 3: Restart (Q5-15) Determines drive response when the suction pressure drops below the level set in Q5-09 for longer than the time set in Q5-10. 0: No display (digital output only) 1: Alarm only 2: Fault 3: Auto-restart (time set by Q5-15) 170 High Suction Pressure Detection Level Hi Pres Detect Sets the level above which the suction pressure must rise for the Default: 0.0 <1> time set in Q5-13 to trigger a drive response according to Q5-14. Min.: 0.0 Setting this parameter to 0.0 disables the function. Max.: 1200.0 – High Suction Pressure Detection Time Hi Pres Det Tm Sets the length of time that the suction pressure must rise above <2> the level set in Q5-12 to trigger a drive response according to Default: 0.1 Min.: 0.0 Q5-14. Max.: 300.0 Time unit is defined by Q5-18. – Suction Min Spd Low Suction Pressure Detection Level Low Pres Detect Low Suction Pressure Detection Time Q5-11 Low Suction Pressure (0F2A) Behavior Select Q5-14 High Suction Pressure (0F2D) Behavior Select Q5-15 (0F2E) Q5-16 (0F2F) Q5-17 (0F30) Hi Pressure Sel 0: No Display 1: Alarm Only 2: Fault 3: Restart (Q5-15) Suction Pressure Auto- Suction Restart Restart Time Suction Control Proportional Gain Sets the length of time for which the pressure must rise above the level set in Q5-06 to wake up the drive when it has been put to sleep via parameter Q5-04, Minimum Suction Pressure. Sets the minimum speed at which the drive will run when the drive is controlling suction pressure. When the drive is controlling outlet pressure or this parameter is set lower than P1-06 and P4-12, parameters P1-06 and P4-12 will be used as the minimum speed. Sets the level below which the suction pressure must fall for the time set in Q5-10 to trigger a drive response according to Q5-11, Low Suction Pressure Behavior Select. Setting this parameter to 0.0 will disable the function. 169 – Suction Pressure Control Minimum Speed Q5-13 (0F2C) Sets the level above which the suction pressure must rise for the Default: 30.0 <1> time set in Q5-07 for the drive to wake up when it has been put Min.: 0.0 to sleep via parameter Q5-04, Minimum Suction Pressure. Max.: 1200.0 – Default: 0.00 Hz Min.: 0.00 Max.: 400.00 Q5-08 (0F27) Q5-12 (0F2B) Default: 5 s Min.: 0 Max.: 3600 Page – Suction Pressure Sleep SP Wake-up Time Wake-Up Time Q5-10 (0F29) Sets the length of time that the drive will delay after suction pressure drops below the level set in Q5-04 before going to sleep. Values Default: 1 s Min.: 0 Max.: 3600 Q5-07 (0F26) Q5-09 (0F28) Description Determines drive response when the suction pressure rises above the level set in Q5-12 for longer than the time set in Q5-13. 0: No display 1: Alarm only 2: Fault 3: Auto-restart (time set by Q5-15) Sets the length of time that the drive will wait before attempting an auto-restart of the Low Suction or High Suction fault. Parameter is only effective when Q5-11 is set to 3 or Q5-14 is set to 3 and L5-01 is greater than 0. Sets the proportional gain for the suction pressure control. Q5-18 (0F31) Suction Pressure Detection Time Unit SuctionPresUnit 0: Minutes (min) 1: Seconds (sec) Q5-19 (0F32) Suction Pressure Analog Input WireBreak Detection SP Wire Break 0: No Display 1: Alarm Only 2: Fault Default: 1 Range: 0 to 3 – Default: 5.0 min Min.: 0.1 Max.: 6000.0 – Default: 2.00 Min.: 0.00 Max.: 25.00 170 Sets the integral time for the suction pressure control. Setting this parameter to 0.0 disables the suction pressure control integrator. Default: 5.0 s Min.: 0.0 Max.: 360.0 170 Sets the time unit for Q5-10 and Q5-13. 0: Minutes (min) 1: Seconds (sec) Sets the behavior when the analog input selected for suction pressure feedback is programmed to receive a 4 to 20 mA signal and the signal is lost. 0: Disabled 1: Alarm only 2: Fault (no retry, coast to stop) Default: 0 Range: 0, 1 – Default: 2 Range: 0 to 2 – Suction P Gain Suction Control Integral Suction I Time Time Default: 1 Range: 0 to 3 <1> Units are determined by Q5-01, Suction Pressure Select, setting. <2> Units are determined by Q5-18, Suction Pressure Detection Time Unit, setting. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Parameter List No. Name LCD Display (Addr. Hex) Q5-05 (0F24) Suction Pressure Sleep SP Sleep Dly Tm Delay Time B 319 B.13 S: Special Application B.13 S: Special Application u S1: Dynamic Noise Control Function No. (Addr. Hex) Name LCD Display S1-01 (3200) Dynamic Audible Noise Dyn Noise Ctrl Control Function 0: Disabled Selection 1: Enabled S1-02 (3201) Voltage Reduction Rate Volt Reduce Amt S1-03 (3202) Voltage Restoration Level Description V/f Values Page Default: 0 Range: 0, 1 – Default: 50.0% Min.: 50.0 Max.: 100.0 – V Reduce On Lvl V/f Default: 20.0% Sets the level when the drive should start restoring the voltage Min.: 0.0 Max.: 90.0 as a percentage of the drive rated torque. – 0: Disabled 1: Enabled V/f Sets the rate at which the output voltage will be reduced as a percentage of the V/f pattern when operating with no load. V/f S1-04 (3203) Voltage Restoration Complete Level V Reduce Off Lvl Default: 50.0% Sets the level at which voltage restoration for the V/f pattern is Min.: S1-03 + complete as a percentage of the drive rated torque. If the output 10.0 torque rises above the value of S1-04, then the voltage will be Max.: 100.0 controlled in a manner specified by the V/f pattern setting. S1-05 (3204) Voltage Restoration Sensitivity Time Constant Sensitivity Time Default: 1.000 s Sets the level of sensitivity of the output torque and LPF time Min.: 0.000 constants for the voltage reduction rate. The level of sensitivity Max.: 3.000 can be adjusted in accordance with the load response. – S1-06 (3205) Voltage Restoration Time Constant at Impact Impact Load Time V/f Default: 0.050 s Sets the voltage restoration time constant if an impact load is Min.: 0.000 Max.: 1.000 added. – – V/f u S2: Programmable Run Timers No. (Addr. Hex) Name LCD Display S2-01 (3206) Sequence Timer 1 Start Tmr 1 Start Time Time S2-02 (3207) Sequence Timer 1 Stop Tmr 1 Stop Time Time S2-03 (3208) S2-04 (3209) 320 Tmr 1 Day Sel 0: Timer disabled 1: Daily 2: Mon - Fri 3: Sat - Sun Sequence Timer 1 Day 4: Monday Selection 5: Tuesday 6: Wednesday 7: Thursday 8: Friday 9: Saturday 10: Sunday Tmr 1 Seq Sel Sequence Timer 1 0: Digital out only Selection 1: Run 2: Run - PI Disable Description Values Sets the start time for timer 1. The value must be set less than Default: 00:00 or equal to S2-02. Min.: 00:00 Max.: 24:00 <1> Sets the stop time for timer 1. The value must be set greater than Default: 00:00 or equal to S2-01. Min.: 00:00 Max.: 24:00 <1> Sets the days for which sequence timer 1 is active. 0: Timer disabled 1: Daily 2: Mon - Fri 3: Sat - Sun Default: 0 4: Monday Range: 0 to 10 5: Tuesday 6: Wednesday 7: Thursday 8: Friday 9: Saturday 10: Sunday Sets the action that occurs when sequence timers 1 is active. Default: 0 0: Digital output only Range: 0 to 2 1: Run 2: Run - PI disable Page – – – – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.13 S: Special Application Name LCD Display Tmr 1 Ref Source 0: Operator (d1-01) 1: Operator (d1-02) 2: Operator (d1-03) 3: Operator (d1-04) 4: Terminals 5: Serial com 6: Option PCB 7: Pulse Input 8: Set by b1-01 S2-05 (320A) Sequence Timer 1 Reference Source S2-06 (320B) Sequence Timer 2 Start Tmr 2 Start Time Time S2-07 (320C) Sequence Timer 2 Stop Tmr 2 Stop Time Time S2-08 (320D) Tmr 2 Day Sel 0: Timer disabled 1: Daily 2: Mon - Fri 3: Sat - Sun Sequence Timer 2 Day 4: Monday Selection 5: Tuesday 6: Wednesday 7: Thursday 8: Friday 9: Saturday 10: Sunday S2-09 (320E) Sequence Timer 2 Selection Tmr 2 Seq Sel 0: Digital out only 1: Run 2: Run - PI Disable S2-10 (320F) Sequence Timer 2 Reference Source Tmr 2 Ref Source 0: Operator (d1-01) 1: Operator (d1-02) 2: Operator (d1-03) 3: Operator (d1-04) 4: Terminals 5: Serial com 6: Option PCB 7: Pulse Input 8: Set by b1-01 S2-11 (3210) Sequence Timer 3 Start Tmr 3 Start Time Time S2-12 (3211) Sequence Timer 3 Stop Tmr 3 Stop Time Time S2-13 (3212) S2-14 (3213) Tmr 3 Day Sel 0: Timer disabled 1: Daily 2: Mon - Fri 3: Sat - Sun Sequence Timer 3 Day 4: Monday Selection 5: Tuesday 6: Wednesday 7: Thursday 8: Friday 9: Saturday 10: Sunday Tmr 3 Seq Sel Sequence Timer 3 0: Digital out only Selection 1: Run 2: Run - PI Disable Description Selects the frequency reference source used for running the drive when sequence timer 1 is active (only applicable when S2-04 is set to 1 or 2). 0: Operator (d1-01) 1: Operator (d1-02) 2: Operator (d1-03) 3: Operator (d1-04) 4: Terminals 5: Serial communication 6: Option card 7: Pulse input 8: Set by b1-01 Sets the start time for timer 2. The value must be set less than or equal to S2-07. Values Default: 8 Range: 0 to 8 Default: 00:00 Min.: 00:00 Max.: 24:00 <1> Sets the stop time for timer 2. The value must be set greater than Default: 00:00 or equal to S2-06. Min.: 00:00 Max.: 24:00 <1> Page – – – Sets the days for which sequence timer 2 is active. 0: Timer disabled 1: Daily 2: Mon - Fri 3: Sat - Sun 4: Monday 5: Tuesday 6: Wednesday 7: Thursday 8: Friday 9: Saturday 10: Sunday Default: 0 Range: 0 to 10 – Sets the action that occurs when sequence timer 2 is active. 0: Digital output only 1: Run 2: Run - PI disable Default: 0 Range: 0 to 2 – Default: 8 Range: 0 to 8 – Selects the frequency reference source used for running the drive when sequence timer 2 is active (only applicable when S2-09 is set to 1 or 2). 0: Operator (d1-01) 1: Operator (d1-02) 2: Operator (d1-03) 3: Operator (d1-04) 4: Terminals 5: Serial communication 6: Option card 7: Pulse input 8: Set by b1-01 Sets the start time for timer 3. The value must be set less than or equal to S2-12. Default: 00:00 Min.: 00:00 Max.: 24:00 <1> Sets the stop time for timer 3. The value must be set greater than Default: 00:00 or equal to S2-11. Min.: 00:00 Max.: 24:00 <1> Sets the days for which sequence timer 3 is active. 0: Timer disabled 1: Daily 2: Mon - Fri 3: Sat - Sun Default: 0 4: Monday Range: 0 to 10 5: Tuesday 6: Wednesday 7: Thursday 8: Friday 9: Saturday 10: Sunday Sets the action that occurs when sequence timer 3 is active. Default: 0 0: Digital output only Range: 0 to 2 1: Run 2: Run - PI disable YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide – – – Parameter List No. (Addr. Hex) – 321 B B.13 S: Special Application No. (Addr. Hex) Name LCD Display Tmr 3 Ref Source 0: Operator (d1-01) 1: Operator (d1-02) 2: Operator (d1-03) 3: Operator (d1-04) 4: Terminals 5: Serial com 6: Option PCB 7: Pulse Input 8: Set by b1-01 S2-15 (3214) Sequence Timer 3 Reference Source S2-16 (3215) Sequence Timer 4 Start Tmr 4 Start Time Time S2-17 (3216) Sequence Timer 4 Stop Tmr 4 Stop Time Time S2-18 (3217) Tmr 4 Day Sel 0: Timer disabled 1: Daily 2: Mon - Fri 3: Sat - Sun Sequence Timer 4 Day 4: Monday Selection 5: Tuesday 6: Wednesday 7: Thursday 8: Friday 9: Saturday 10: Sunday S2-19 (3218) Sequence Timer 4 Selection Sequence Timer 4 Reference Source S2-20 (3219) Description Selects the frequency reference source used for running the drive when sequence timer 3 is active (only applicable when S2-14 is set to 1 or 2). 0: Operator (d1-01) 1: Operator (d1-02) 2: Operator (d1-03) 3: Operator (d1-04) 4: Terminals 5: Serial communication 6: Option card 7: Pulse input 8: Set by b1-01 Sets the start time for timer 4. The value must be set less than or equal to S2-17. Values Default: 8 Range: 0 to 8 Default: 00:00 Min.: 00:00 Max.: 24:00 <1> Sets the stop time for timer 4. The value must be set greater than Default: 00:00 or equal to S2-16. Min.: 00:00 Max.: 24:00 <1> Page – – – Sets the days for which sequence timer 4 is active. 0: Timer disabled 1: Daily 2: Mon - Fri 3: Sat - Sun 4: Monday 5: Tuesday 6: Wednesday 7: Thursday 8: Friday 9: Saturday 10: Sunday Default: 0 Range: 0 to 10 – Tmr 4 Seq Sel 0: Digital out only 1: Run 2: Run - PI Disable Sets the action that occurs when sequence timer 4 is active. 0: Digital output only 1: Run 2: Run - PI disable Default: 0 Range: 0 to 2 – Tmr 4 Ref Source 0: Operator (d1-01) 1: Operator (d1-02) 2: Operator (d1-03) 3: Operator (d1-04) 4: Terminals 5: Serial com 6: Option PCB 7: Pulse Input 8: Set by b1-01 Selects the frequency reference source used for running the drive when sequence timer 4 is active (only applicable when S2-19 is set to 1 or 2). 0: Operator (d1-01) 1: Operator (d1-02) 2: Operator (d1-03) 3: Operator (d1-04) 4: Terminals 5: Serial communication 6: Option card 7: Pulse input 8: Set by b1-01 Default: 8 Range: 0 to 8 – <1> Setting the sequence timer start time to a higher value than the sequence timer stop time disables that sequence timer. u S3: Secondary PI (PI2) Control No. (Addr. Hex) S3-01 (321A) S3-02 (321B) 322 Name Secondary PI Enable Selection Secondary PI User Display LCD Display PI2 Enable Sel 0: Disabled 1: Always 2: Drive running 3: Motor running PI2 UsrDspMaxVal Description Determines when the secondary PI controller is enabled. 0: Disabled 1: Always 2: Drive running 3: Motor running Setting 3 does not run the motor at zero speed, baseblock, or in DC injection. Sets the scale value of 100% PI input. Values Page Default: 0 Range: 0 to 3 – Default: 10000 Min.: 0 Max.: 60000 – Note: YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.13 S: Special Application S3-03 (321C) S3-04 (321D) S3-05 (321E) S3-06 (321F) S3-07 (3220) S3-08 (3221) Name Secondary PI Display Digits Secondary PI Unit Selection LCD Display PI2 UsrDspDigits 0: No Dec (XXXXX) 1: 1 Dec (XXXX.X) 2. 2 Dec (XXX.XX) 3: 3 Dec (XX.XXX) PI2 Unit Sel 0: WC 1: PSI 2: GPM 3: °F 4: CFM 5: CMH 6: LPH 7: LPS 8: Bar 9: Pa 10: °C 11: Mtr 12: LPM 13: CMM 14: No unit 15: % Description PI2 Setpoint Secondary PI Proportional Gain Setting PI2 Gain Secondary PI Integral Time Setting PI2 I Time Secondary PI Integral Limit Setting PI2 I Limit Secondary PI Output Upper Limit PI2 Upper Limit Secondary PI Output Lower Limit Page Sets the decimal place display for secondary PI units. 0: No decimal places 1: One decimal place 2: Two decimal places 3: Three decimal places Default: 2 Range: 0 to 3 – 0: Inch of water (WC) 1: Pounds per square inch (PSI) 2: Gallons per minute (GPM) 3: Degrees Fahrenheit (F) 4: Cubic feet per minute (CFM) 5: Cubic meters per hour (CMH) 6: Liters per hour (LPH) 7: Liters per second (LPS) 8: Bar (Bar) 9: Pascals (Pa) 10: Degrees Celsius (C) 11: Meters (Mtr) (Ft: Feet) 12: Liters per minute (LPM) 13: Cubic meters per minute (CMM) 14: No unit 15: Percentage (%) Default: 15 Range: 0 to 15 – Default: 0.00 <1> Min.: 0.00 Max.: 600.00 <2> – Default: 1.00 Min.: 0.00 Max.: 25.00 – Sets the integral time for the secondary PI controller. A setting Default: 1.0 s of 0.0 s disables integral control. Min.: 0.0 Max.: 360.0 – Sets the secondary PI controller target value. Secondary PI Setpoint Value Values Sets the proportional gain of the secondary PI controller. A setting of 0.00 disables P control. Sets the maximum output possible from the integrator. Default: 100.0% Min.: 0.0 Max.: 100.0 – Sets the maximum output possible from the secondary PI controller. Default: 100.0% Min.: 0.0 Max.: 100.0 – PI2 Lower Lim Sets the minimum output possible from the secondary PI controller. Default: 0.00% Min.: -100.00 Max.: 100.00 – Secondary PI Output Level Selection PI2 Out Lvl Sel 0: Direct Acting 1: Inverse Acting Sets the secondary PI controller output direction. 0: Normal Output (direct acting) 1: Inverse Output (inverse acting) Default: 0 Range: 0, 1 – Secondary PI Disable Mode PI2 Disable Mode 0: No output 1: Lower Limit (S3-10) 2: Setpoint Default: 0 Range: 0 to 2 – S3-13 (3226) Secondary PI Low Feedback Detection Level Selects the secondary PI controller output when disabled. 0: No output (0%) 1: Lower Limit (S3-10) 2: Setpoint Sets the secondary PI low feedback detection level. PI2 Low FB Lvl Default: 0.00 <1> Min.: 0.00 Max.: 600.00 <2> – S3-14 (3227) Secondary PI Low Feedback Detection Time PI2 Low FB Time Sets the secondary PI low feedback detection delay time in seconds. Default: 1.0 s Min.: 0.0 Max.: 25.5 – Sets the secondary PI high feedback detection level. Default: 100.00 S3-09 (3222) S3-10 (3223) S3-11 (3224) S3-12 (3225) S3-15 (3228) S3-16 (3229) Secondary PI High Feedback Level PI2 High FB Lvl Secondary PI High Feedback Detection Time PI2 High FB Tim <1> Min.: 0.00 Max.: 600.00 <2> Sets the secondary PI high feedback detection delay time in seconds. Default: 1.0 s Min.: 0.0 Max.: 25.5 – – Parameter List No. (Addr. Hex) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 323 B.13 S: Special Application No. (Addr. Hex) S3-17 (322A) Name LCD Display FB Det Sel Secondary PI Feedback PI2 0: PI2 Enabled Detection Selection 1: Always Description Selects when secondary PI controller low and high feedback detection are active. 0: Secondary PI enabled 1: Always Values Default: 0 Range: 0, 1 Page – <1> Unit is determined by S3-04. <2> Upper limit is S3-02, decimal placeholder is determined by S3-03. u S6: Protection No. (Addr. Hex) Name LCD Display Description Values Page S6-01 (3236) Emergency Override Speed E Override Speed Sets the speed command used in emergency override mode when S6-02 = 0. Default: 0.00 Hz Min.: 0.00 Max.: 240.00 – S6-02 (3237) Emergency Override Reference Selection E OverrideRefSel 0: Use S6-01 Ref 1: Use Freq Ref Selects the emergency override speed source. 0: Use S6-01 Reference 1: Use Frequency Reference Default: 0 Range: 0, 1 – S6-07 (323C) Output Phase Loss Level for Dynamic Noise Control DNC Outp Ph Loss Reduces the output phase loss level when Dynamic Noise Control is active. Default: 100.0% Min.: 10.0 Max.: 100.0 – 324 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.14 T: Motor Tuning B.14 T: Motor Tuning Enter data into the following parameters to tune the motor and drive for optimal performance. u T1: Induction Motor Auto-Tuning No. (Addr. Hex) T1-01 (0701) Name Auto-Tuning Mode Selection LCD Display Tuning Mode Sel 0: Standard Tuning 1: Tune-No Rotate1 2: Term Resistance 3: V/f Engy Sav Tun 4: Tune-No Rotate2 Description 0: Standard 1: Tune-No Rotate1 2: Stationary Auto-Tuning for Line-to-Line Resistance 3: Rotational Auto-Tuning for V/f Control Energy Saving 4: Tune-No Rotate2 Values Default: <1> Range: 0 to 4 Sets the motor rated power as specified on the motor nameplate. Default: <2> Note: Use the following formula to convert horsepower Min.: 0.00 kW Max.: 650.00 into kilowatts: kW 1HP = 0.746 kW. Sets the motor rated voltage as specified on the motor Default: 200.0 nameplate. V <3> Min: 0.0 Max: 255.0 <3> Sets the motor rated current as specified on the motor Default: <2> nameplate. Min.: 10% of drive rated current Max.: 200% of drive rated current Sets the rated frequency of the motor as specified on the motor Default: 60.0 Hz nameplate. Min.: 0.0 Max.: 400.0 Page – T1-02 (0702) Motor Rated Power Mtr Rated Power T1-03 (0703) Motor Rated Voltage Rated Voltage T1-04 (0704) Motor Rated Current Rated Current T1-05 (0705) Motor Base Frequency Rated Frequency T1-06 (0706) Number of Motor Poles Number of Poles Sets the number of motor poles as specified on the motor nameplate. Default: 4 Min.: 2 Max.: 48 – T1-07 (0707) Motor Base Speed Sets the rated speed of the motor as specified on the motor nameplate. Default: 1750 r/ min Min.: 0 Max.: 24000 – Rated Speed – – – – OLV T1-09 (0709) Motor No-Load Current Motor No-Load (Stationary AutoCurrent Tuning) Sets the no-load current for the motor. After setting the motor Default: – capacity to T1-02 and the motor rated current to T1-04, this Min.: 0 A parameter will automatically display the no-load current for a Max.: T1-04 standard 4-pole Yaskawa motor. Enter the no-load current as indicated on the motor test report. T1-10 (070A) Motor Rated Slip (Stationary AutoTuning) Sets the motor rated slip. After setting the motor capacity to Default: – T1-02, this parameter will automatically display the motor slip Min.: 0.00 Hz for a standard 4-pole Yaskawa motor. Enter the motor slip as Max.: 20.00 Hz indicated on the motor test report. – OLV Motor Rated Slip – V/f T1-11 (070B) Motor Iron Loss Mtr Iron Loss(W) Default: 14 W Sets the iron loss for determining the Energy Saving coefficient. <4> The value is set to E2-10 (motor iron loss) set when the power Min.: 0 is cycled. If T1-02 is changed, a default value appropriate for Max.: 65535 the motor capacity that was entered will appear. – Parameter List <1> Default depends on parameter A1-02, Control Mode Selection. Setting 0 (V/f): Default is 2. Setting 2 (OLV): Default is 0 <2> Default setting is dependent on parameter o2-04, Drive Model Selection. <3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives. <4> Default setting value differs depending on the motor code value and motor parameter settings. B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 325 B.15 U: Monitors B.15 U: Monitors Monitor parameters allow the user to view drive status, fault information, and other data concerning drive operation. u U1: Operation Status Monitors No. (Addr. Hex) U1-01 (0040) U1-02 (0041) U1-03 (0042) U1-04 (0043) Name LCD Display Analog Output Level Description Monitors the frequency reference. Display units are determined by o1-03. Displays the output frequency. Display units are determined by o1-03. Displays the output current. 10 V: Max 0.01 Hz frequency 10 V: Max 0.01 Hz frequency 10 V: Drive <1> <2> rated current No signal output – available Frequency Reference Frequency Ref Output Frequency Output Freq Output Current Output Current Control Method Control Method 0: V/f Control 2: OLV Control U1-05 (0044) Motor Speed Motor Speed Displays the motor speed feedback. Display units are determined by o1-03. U1-06 (0045) Output Voltage Reference Output Voltage U1-07 (0046) DC Bus Voltage DC Bus Voltage Displays the DC bus voltage. Displays the output power (this value is calculated internally). 10 V: Drive capacity (motor capacity) kW OLV U1-08 (0047) Output Power Output kWatts U1-09 (0048) Torque Reference Torque Reference Displays the output voltage. Unit 10 V: Max frequency 0.01 Hz 10 V: 200 Vrms 0.1 Vac <3> 10 V: 400 V <3> 10 V: Motor rated torque OLV Monitors the internal torque reference. 1 Vdc <4> 0.1% Displays the input terminal status. U1 - 10= 00000000 1 Digital input 1 (terminal S1 enabled) 1 Digital input 2 (terminal S2 enabled) 1 Digital input 3 U1-10 (0049) Input Terminal Status 1 Input Term Sts 1 1 1 1 (terminal S3 enabled) Digital input 4 (terminal S4 enabled) Digital input 5 (terminal S5 enabled) Digital input 6 (terminal S6 enabled) Digital input 7 (terminal S7 enabled) Digital input 8 (terminal S8 enabled) No signal output available – No signal output available – Displays the output terminal status. U1 - 11= 00000000 1 Multi-Function Digital Output (terminal M1-M2) U1-11 (004A) Output Terminal Status Output Term Sts 1 Multi-Function Digital Output 1 0 1 326 (terminal M3-M4) Multi-Function Digital Output (terminal MD-ME-MF) Not Used Fault Relay (terminal MA-MC closed MA-MC open) YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.15 U: Monitors No. (Addr. Hex) Name LCD Display Description Analog Output Level Unit No signal output available – Verifies the drive operation status. U1 - 12= 00000000 U1-12 (004B) Drive Status Int Ctl Sts 1 1 During run 1 During zero-speed 1 During REV fault reset 1 During signal input 1 During speed agree 1 Drive ready alarm 1 During detection 1 During fault detection U1-13 (004E) U1-14 (004F) U1-15 (0050) Terminal A1 Input Level Terminal A2 Input Level Terminal A3 Input Level Term A1 Level Displays the signal level to analog input terminal A1. 10 V: 100% 0.1% Term A2 Level Displays the signal level to analog input terminal A2. 10 V: 100% 0.1% Term A3 Level Displays the signal level to analog input terminal A3. 10 V: 100% 0.1% U1-16 (0053) Output Frequency after SFS Output Soft Starter Displays output frequency with ramp time and S-curves. Units 10 V: Max determined by o1-03. frequency U1-18 (0061) oPE Fault Parameter Displays the parameter number that caused the oPE02 operation No signal output error. available OPE Error Code 0.01 Hz – Displays the contents of a MEMOBUS/Modbus error. 1 CRC Error 1 Data Length Error 0 Not Used 1 Parity Error 1 Overrun Error 1 Framing Error 1 Timed Out 0 Not Used U1-19 (0066) MEMOBUS/Modbus Error Code Transmit Err U1-24 (007D) Input Pulse Monitor Term RP Inp Freq Displays the frequency to pulse train input terminal RP. Determined by H6-02 U1-25 (004D) Software Number (Flash) CPU 1 SW Number FLASH ID No signal output available – U1-26 (005B) U1-75 (0851) U1-76 (0852) U1-77 (0853) Software No. (ROM) CPU 2 SW Number ROM ID – Time-Hour/Minute Time Hr Min HHMM Displays the current time (Hours and Minutes). Date – Year Date Year Date – Month/Day Date Mo Day MMDD Displays the current date (Month and Date). No signal output available No signal output available No signal output available No signal output available U1-78 (0854) Date – Week Day U1-80 Geothermal (0B9B) Temperature Input Date Week Geothermal Temp Displays the current year. Displays the current day of the week. 0: Sunday 1: Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday Displays the geothermal temperature input after the gain and bias have been applied. This temperature is used by the Geothermal Function to determine the proper frequency at which to run the drive. This monitor is internally limited to -999.9 °F to +999.9 °F. No signal output available No signal output available – 1 Hz – – – – No signal output 0.1 °F available Parameter List U1 - 19= 00000000 B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 327 B.15 U: Monitors No. (Addr. Hex) Name LCD Display U1-83 (0B9E) Flow Rate Flow Rate U1-84 (0B9F) U1-85 (0BA0) U1-86 (0BA1) U1-87 (0BA2) U1-90 (0BA5) U1-91 (0BA6) Accumulation Level Millions Accumulation Level Thousands Accumulation Level Ones Accumulation Level Decimal Volume * 1000000 Volume * 1000 Volume * 1 Analog Output Level Description Displays the flow rate based on the pulse input frequency or the Full scale: P6-01 analog voltage (flow rate input) and parameters P6-01 and setting P6-04. A 2-second first order filter will be applied to this monitor. Displays the recorded volume from the flow meter (pulse input or analog voltage). Total volume is calculated as follows: Total Volume = (U1-84 * 1000000) + (U1-85 * 1000) + U1-86 No signal output + U1-87 available Unit dep. on P6-04 dep. on P6-16 Volume * 0.0001 Pump Setpoint Pump Setpoint Displays the PID Setpoint. Pump Feedback Pump Feedback Displays the PID Feedback. No signal output available No signal output available dep. on P1-02 dep. on P1-02 No signal output available – Displays Pump Running Status. U1 - 92= 00000000 1 Drive 1 Pump 2 1 Pump 3 1 Pump 4 1 Pump 5 1 Pump 6 0 Not used 0 Not used U1-92 (0BA7) Pump Status Pump Status U1-93 Total Setpoint (0BA8) Compensation Total SP Comp. Displays the total absolute Setpoint Compensation. No signal output dep. on available P1-02 U1-94 Motor Speed (0BA9) Motor Speed Displays the absolute value of the output frequency (U1-02) converted to RPM. No signal output 1 RPM available U1-97 Water Level (0BAC) Water Level Displays the amount of water above the water level sensor. Full scale: 10 V = Q4-02 0.1 ft. U1-98 Suction Pressure (0BAD) Suction Pressure Displays the amount of suction pressure. Full scale: 10 V = Q5-02 0.1 PSI or ”Hg U1-99 Anti-No-Flow Timer (0BAE) ANF Timer The Anti-No-Flow reduces the output frequency when this value reaches the P2-24 setting. No signal output available 0.1 s <1> The number of decimal places in the parameter value depends on the drive model and the ND selection. This value has two decimal places (0.01 A) if the drive is set for a maximum applicable motor capacity up to and including 11 kW, and one decimal place (0.1 A) if the maximum applicable motor capacity is higher than 11 kW. <2> When reading the value of this monitor via MEMOBUS/Modbus, a value of 8192 is equal to 100% of the drive rated output current. <3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives. <4> The display resolution depends on the ND selection. This value has two decimal places (0.01 kW) if the drive is set for a maximum applicable motor capacity up to and including 11 kW, and one decimal place (0.1 kW) if the maximum applicable motor capacity is higher than 11 kW. u U2: Fault Trace No. (Addr. Hex) U2-01 (0080) U2-02 (0081) U2-03 (0082) 328 Name LCD Display Description Current Fault Current Fault Displays the current fault. Previous Fault Last Fault Displays the previous fault. Frequency Reference at Frequency Ref Previous Fault Displays the frequency reference at the previous fault. Analog Output Level Unit No signal output – available No signal output – available No signal output 0.01 Hz available YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.15 U: Monitors No. (Addr. Hex) U2-04 (0083) U2-05 (0084) U2-07 (0086) U2-08 (0087) U2-09 (0088) Output Frequency at Previous Fault Output Current at Previous Fault Output Voltage at Previous Fault DC Bus Voltage at Previous Fault Output Power at Previous Fault U2-10 (0089) Torque Reference at Previous Fault U2-11 (008A) U2-12 (008B) U2-13 (008C) Name LCD Display Description Output Freq Displays the output frequency at the previous fault. Output Current Displays the output current at the previous fault. Output Voltage Displays the output voltage at the previous fault. DC Bus Voltage Displays the DC bus voltage at the previous fault. Output kWatts Displays the output power at the previous fault. Analog Output Level Unit No signal output available No signal output available No signal output available No signal output available No signal output available 0.01 Hz <1> <2> 0.1 Vac 1 Vdc 0.1 kW Displays the torque reference at the previous fault. No signal output available 0.1% Input Terminal Status at Input Term Sts Previous Fault Output Terminal Status Output Term Sts at Previous Fault Drive Operation Status Inverter Status at Previous Fault Displays the input terminal status at the previous fault. Displayed as in U1-10. Displays the output status at the previous fault. Displays the same status displayed in U1-11. Displays the operation status of the drive at the previous fault. Displays the same status displayed in U1-12. No signal output available No signal output available No signal output available – U2-14 (008D) Cumulative Operation Elapsed time Time at Previous Fault Displays the cumulative operation time at the previous fault. No signal output available U2-15 (07E0) Soft Starter Speed Reference at Previous Fault Displays the speed reference for the soft starter at the previous No signal output 0.01 Hz fault. available U2-16 (07E1) Motor q-Axis Current at Motor Iq Current Previous Fault Displays the q-axis current for the motor at the previous fault. No signal output 0.10% available U2-17 (07E2) Motor d-Axis Current at Motor Id Current Previous Fault OLV No signal output 0.10% Displays the d-axis current for the motor at the previous fault. available U2-20 (008E) U2-30 (3008) U2-31 (3009) Heatsink Temperature at Previous Fault Date Year at Previous Fault Date Month and Day at Previous Fault Time Hours and Minutes at Previous Fault U2-32 (300A) Torque Reference SFS Output OLV Displays the temperature of the heatsink when the most recent No signal output fault occurred. available Displays the year when the most recent fault occurred. No signal output Date Year YYYY available Displays the date and day when the most recent fault occurred. No signal output Date Mo Day MMDD available Displays the time when the most recent fault occurred. No signal output Time Hr Min HHMM available Actual Fin Temp – – 1h 1 °C – – – <1> The number of decimal places in the parameter value depends on the drive model and the ND selection. This value has two decimal places (0.01 A) if the drive is set for a maximum applicable motor capacity up to and including 11 kW, and one decimal place (0.1 A) if the maximum applicable motor capacity is higher than 11 kW. <2> When reading the value of this monitor via MEMOBUS/Modbus, a value of 8192 is equal to 100% of the drive rated output current. No. Name LCD Display (Addr. Hex) U3-01 to U3-04 First to 4th Most Recent (90 to 93 Fault Fault Message o (0800 to 0803)) Displays the first to the fourth most recent faults. U3-05 to U3-10 5th to 10th Most Recent Fault Message o (0804 to Fault 0809) Displays the fifth to the tenth most recent faults. After ten faults, data for the oldest fault is deleted. The most recent fault appears in U3-01, with the next most recent fault appearing in U3-02. The data is moved to the next monitor parameter each time a fault occurs. Description Analog Output Level Unit No signal output available – No signal output available – Parameter List u U3: Fault History B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 329 B.15 U: Monitors No. (Addr. Hex) U3-11 to U3-14 (94 to 97 (080A to 080D)) U3-15 to U3-20 (080E to 0813) U3-21 (300B) U3-22 (300C) Name LCD Display Cumulative Operation Time at 1st to 4th Most Elapsed Time o Recent Fault Description Displays the cumulative operation time when the first to the fourth most recent faults occurred. Analog Output Level Unit No signal output available 1h No signal output available 1h Cumulative Operation Time at 5th to 10th Most Elapsed Time o Recent Fault Displays the cumulative operation time when the fifth to the tenth most recent faults occurred. No signal output available No signal output Displays the date and day when the most recent faults occurred. available U3-24 (300E) Date Year at Most Recent Fault Date Month and Day at Most Recent Fault Time Hours and Minutes at Most Recent Fault Date Year at 2nd Most Recent Fault U3-25 (300F) U3-23 (300D) Fault 1 YYYY Fault 1 MMDD Displays the year when the most recent fault occurred. – – Fault 1 HHMM Displays the time when the most recent fault occurred. No signal output available – Fault 2 YYYY Displays the year when the second most recent fault occurred. No signal output available – Date Month and Day at Fault 2 MMDD 2nd Most Recent Fault Displays the date and day when the second most recent fault occurred. No signal output available – U3-26 (3010) Time Hours and Minutes at 2nd Most Recent Fault Fault 2 HHMM signal output Displays the time when the second most recent fault occurred. No available – U3-27 (3011) Date Year at 3rd Most Recent Fault Fault 3 YYYY Displays the year when the most third recent fault occurred. No signal output available – U3-28 (3012) Date Month and Day at Fault 3 MMDD 3rd Most Recent Fault Displays the date and day when the third most recent fault occurred. No signal output available – U3-29 (3013) Time Hours and Minutes at 3rd Most Recent Fault Fault 3 HHMM Displays the time when the third most recent fault occurred. No signal output available – U3-30 (3014) Date Year at 4th Most Recent Fault Fault 4 YYYY Displays the year when the fourth most recent fault occurred. No signal output available – U3-31 (3015) Date Month and Day at Fault 4 MMDD 4th Most Recent Fault Displays the date and day when the fourth most recent fault occurred. No signal output available – U3-32 (3016 Time Hours and Minutes at 4th Most Recent Fault Fault 4 HHMM signal output Displays the time when the fourth most recent fault occurred. No available – U3-33 (3017) Date Year at 5th Most Recent Fault Fault 5 YYYY Displays the year when the fifth most recent fault occurred. No signal output available – U3-34 (3018) Date Month and Day at 5th Most Recent Fault Time Hours and Minutes at 5th Most Recent Fault Date Year at 6th Most Recent Fault Date Month and Day a 6th Most Recent Fault Time Hours and Minutes at 6th Most Recent Fault Date Year at 7th Most Recent Fault Date Month and Day at 7th Most Recent Fault Time Hours and Minutes at 7th Most Recent Fault Date Year at 8th Most Recent Fault Fault 5 MMDD Displays the date and day when the fifth most recent fault occurred. No signal output available – Fault 5 HHMM Displays the time when the fifth most recent fault occurred. No signal output available – Fault 6 YYYY Displays the year when the sixth most recent fault occurred. – Fault 6 MMDD Displays the date and day when the sixth most recent fault occurred. No signal output available No signal output available Fault 6 HHMM Displays the time when the sixth most recent fault occurred. No signal output available – Fault 7 YYYY Displays the year when the seventh most recent fault occurred. No signal output available Displays the date and day when the seventh most recent fault No signal output occurred. available – U3-35 (3019) U3-36 (301A) U3-37 (301B) U3-38 (301C) U3-39 (301D) U3-40 (301E) U3-41 (301F) U3-42 (3020) 330 Fault 7 MMDD – – Fault 7 HHMM signal output Displays the time when the seventh most recent fault occurred. No available – Fault 8 YYYY Displays the year when the eighth most recent fault occurred. No signal output available – YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.15 U: Monitors No. (Addr. Hex) U3-43 (3021) U3-44 (3022) U3-45 (3023) U3-46 (3024) U3-47 (3025) U3-48 (3026) U3-49 (3027) U3-50 (3028) Name Date Month and Day 8th at Most Recent Fault Time Hours and Minutes at 8th Most Recent Fault Date Year at 9th Most Recent Fault Date Month and Day at 9th Most Recent Fault Time Hours and Minutes at 9th Most Recent Fault Date Year at 10th Most Recent Fault Date Month and Day at 10th Most Recent Fault Time Hours and Minutes at 10th Most Recent LCD Display Description Analog Output Level Unit Fault 8 MMDD Displays the date and day when the eighth most recent fault occurred. No signal output available – Fault 8 HHMM signal output Displays the time when the eighth most recent fault occurred. No available – Fault 9 YYYY Displays the year when the ninth most recent fault occurred. – Fault 9 MMDD Displays the date and day when the ninth most recent fault occurred. No signal output available No signal output available Fault 9 HHMM Displays the time when the ninth most recent fault occurred. No signal output available – Fault 10 YYYY Displays the year when the tenth most recent fault occurred. – Fault 10 MMDD Displays the date and day when the tenth most recent fault occurred. No signal output available No signal output available Fault 10 HHMM Displays the time when the tenth most recent fault occurred. No signal output available – Analog Output Level Unit No signal output available 1h – – u U4: Maintenance Monitors Name LCD Display U4-01 (004C) Cumulative Operation Time Drv Elapsed Time U4-02 (0075) Number of Run Commands RUN Cmd Counter U4-03 (0067) Cooling Fan Operation Fan Elapsed TIme Time U4-04 (007E) Cooling Fan Maintenance U4-05 (007C) Capacitor Maintenance Cap Life Mon U4-06 (07D6) Soft Charge Bypass Relay Maintenance ChgCirc Life Mon U4-07 (07D7) IGBT Maintenance IGBT Life Mon U4-08 (0068) Heatsink Temperature Heatsink Temp U4-09 (005E) LED Check LED Oper Check Fan Life Mon Description Displays the cumulative operation time of the drive. The value for the cumulative operation time counter can be reset in parameter o4-01. Use parameter o4-02 to determine if the operation time should start as soon as the power is switched on or only while the Run command is present. The maximum number displayed is 99999, after which the value is reset to 0. Displays the number of times the Run command is entered. Reset the number of Run commands using parameter o4-13. This value will reset to 0 and start counting again after reaching 65535. Displays the cumulative operation time of the cooling fan. The default value for the fan operation time is reset in parameter o4-03. This value will reset to 0 and start counting again after reaching 99999. Displays main cooling fan usage time as a percentage of its expected performance life. Parameter o4-03 can be used to reset this monitor. Replace the fan when this monitor reaches 90%. Displays main circuit capacitor usage time as a percentage of their expected performance life. Parameter o4-05 can be used to reset this monitor. Replace the capacitor when this monitor reaches 90%. Displays the soft charge bypass relay maintenance time as a percentage of its estimated performance life. Parameter o4-07 can be used to reset this monitor. Replace the soft charge bypass relay when this monitor reaches 90%. Displays IGBT usage time as a percentage of the expected performance life. Parameter o4-09 can be used to reset this monitor. Replace the IGBT when this monitor reaches 90%. Displays the heatsink temperature. Lights all segments of the LED to verify that the display is working properly. Press the ENTER key to turn the LEDs on and press ESC to turn the LEDs off. No signal output 1 Time available No signal output available 1h No signal output available 1% No signal output available 1% No signal output available 1% No signal output available 1% 10 V: 100 °C 1 °C No signal output available – Parameter List No. (Addr. Hex) B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 331 B.15 U: Monitors No. (Addr. Hex) U4-10 (005C) Name LCD Display kWh, Lower 4 Digits kWh Lower 4 dig U4-11 (005D) kWh, Upper 5 Digits kWh Upper 5 dig U4-13 (07CF) Peak Hold Current Current PeakHold U4-14 (07D0) U4-16 (07D8) Peak Hold Output Frequency Motor Overload Estimate (oL1) Freq@ I PeakHold Motor OL1 Level Description No signal output 1 kWh available Displays the output frequency when the current value shown in U4-13 occurred. Shows the value of the motor overload detection accumulator. 100% is equal to the oL1 detection level. Displays the source for the frequency reference as XY-nn. X: indicates which reference is used: 1 = Reference 1 (b1-01) Y-nn: indicates the reference source 0-01 = Digital operator 1-01 = Analog (terminal A1) 1-02 = Analog (terminal A2) 1-03 = Analog (terminal A3) 2-02 to 17 = Multi-step speed (d1-02 to 17) 3-01 = MEMOBUS/Modbus communications 4-01 = Communication option card 5-01 = Pulse input No signal output 0.01 Hz available Reference Source U4-19 Frequency Reference (07DB) from MEMOBUS/ Modbus Comm. Displays the frequency reference provided by MEMOBUS/ MEMOBUS Freq Ref Modbus (decimal). U4-20 Option Frequency (07DC) Reference Option Freq Ref U4-22 MEMOBUS/Modbus MEMOBUS Ref Reg (07DE) Communications Reference U4-23 Communication Option Option Ref Reg (07DF) Card Reference U4-32 (07FB) Motor Temperature (NTC) Motor Temperature (NTC) Unit Monitors the drive output power usage (or consumption). The value is shown as a 9-digit number displayed across two monitor parameters, U4-10 and U4-11. Example: 12345678.9 kWh is displayed as: U4-10: 678.9 kWh U4-11: 12345 MWh Displays the highest current value that occurred during run. U4-18 Frequency Reference (07DA) Source Selection U4-21 Run Command Source Run Cmd Source (07DD) Selection Analog Output Level Displays the frequency reference input by an option card (decimal). Displays the source for the Run command as XY-nn. X: Indicates which Run source is used: 1 = Reference 1 (b1-02) Y: Input power supply data 0 = Digital operator 1 = External terminals 3 = MEMOBUS/Modbus communications 4 = Communication option card nn: Run command limit status data 00: No limit status. 01: Run command was left on when stopped in the PRG mode 02: Run command was left on when switching from LOCAL to REMOTE operation 03: Waiting for soft charge bypass contactor after power up (Uv or Uv1 flashes after 10 s) 04: Waiting for “Run command prohibited” time period to end 05: Fast Stop (digital input, digital operator) 06: b1-17 (Run command given at power-up) 07: During baseblock while coast to stop with timer 08: Frequency reference is below minimal reference during baseblock 09: Waiting for Enter command Displays the drive control data set by MEMOBUS/Modbus communications register no. 0001H as a four-digit hexadecimal number. Displays drive control data set by an option card as a four-digit hexadecimal number. Displays the motor temperature (NTC). U4-32 will display “20 °C” when a multi-function analog input is not set for motor thermistor input (H1-oo = 17H). Monitor is only present when a digital input is programmed for 17 (Thermistor Input). No signal output 1 MWh available No signal output 0.01 A <1> available 10 V: 100% No signal output available 0.1% – No signal output 0.01% available No signal output available – No signal output available – No signal output available – No signal output available – 200 °C 1 °C <1> When reading the value of this monitor via MEMOBUS/Modbus, a value of 8192 is equal to 100% of the drive rated output current. 332 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide B.15 U: Monitors u U5: PID Monitors No. (Addr. Hex) Name U5-01 (0057) PID Feedback 1 PID Feedback 1 U5-02 (0063) U5-03 (0064) PID Input PID Input PID Output PID Output U5-04 (0065) PID Setpoint PID Setpoint U5-05 (07D2) PID Differential Feedback PID Feedback 2 U5-06 (07D3) PID Adjusted Feedback PID Diff Fdbk U5-14 (086B) PI Output 2 Upper 4 Digits PI Output2 U4 U5-15 (086C) PI Output 2 Lower 4 Digits PI Output2 L4 Displays the custom PI output. No signal output U5-14 shows the upper 4 digits while U5-15 shows the lower 4 available digits. Monitors are scaled by b5-43 and b5-44. U5-17 (086E) PI2 Setpoint PI2 Setpoint Displays the secondary PI setpoint. Dependent upon S3-02 <3> U5-18 (086F) PI2 Feedback PI2 Feedback Displays the secondary PI feedback value. Dependent upon S3-02 <3> U5-19 (0870) PI2 Input PI2 Input Displays the secondary PI input (deviation between PI target and feedback). Dependent upon S3-02 <3> U5-20 (0871) PI2 Output PI2 Output Displays the secondary PI control output. Dependent upon S3-02 <3> U5-30 (3000) Time Hr Min HHMM Time Hr Min HHMM Displays the current time (Hours and Minutes). No signal output available 1 U5-31 (3001) Date Year Date Year No signal output available 1 U5-32 (3002) Date Mo Day MMDD Date Mo Day MMDD Displays the current date (Month and Day). No signal output available 1 U5-33 (3003) Date Week 000W Date Week 0: Sunday 1: Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday Displays the current date of the week. 0: Sunday 1: Monday 2: Tuesday 3: Wednesday 4: Thursday 5: Friday 6: Saturday No signal output available 1 U5-99 (1599) AUTO Setpoint Auto Setpoint Displays the PID Setpoint commanded by the source when the No signal output 0.01% <1> drive is in AUTO Mode. available LCD Display Description Displays the PID feedback value. Displays the amount of PID input (deviation between PID setpoint and feedback). Displays PID control output. Displays the PID setpoint. Displays the 2nd PID feedback value if differential feedback is used (H3-oo = 16). Displays the difference of both feedback values if differential feedback is used (U5-01 - U5-05). If differential feedback is not used, then U5-01 and U5-06 will be the same. Displays the custom PI output. U5-14 shows the upper 4 digits while U5-15 shows the lower 4 digits. Monitors are scaled by b5-43 and b5-44. Displays the current year. Analog Output Level Unit 10 V: 100% 0.01% 10 V: 100% 0.01% 10 V: 100% 0.01% 10 V: 100% 0.01% 10 V: 100% 0.01% 10 V: 100% 0.01% No signal output available <1> <1> 1 <2> 0.01 <2> Parameter List <1> Unit, range and resolution is determined by b5-20, b5-38, b5-39, and b5-46 <2> Unit is determined by b5-41 <3> Unit is determined by S3-04. B YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 333 B.15 U: Monitors u U6: Operation Status Monitors No. (Addr. Hex) Name LCD Display Description Analog Output Level Unit U6-01 (0051) Motor Secondary Current (Iq) Mot SEC Current Displays the value of the motor secondary current (Iq). Motor 10 V: Motor rated secondary current is 100%. secondary rated current 0.1% U6-02 (0052) Motor Excitation Current (Id) Mot EXC Current OLV 10 V: Motor Displays the value calculated for the motor excitation current secondary rated current (Id). Motor rated secondary current is 100%. 0.1% U6-05 (0059) Output Voltage Reference (Vq) Voltage Ref (Vq) U6-06 (005A) Output Voltage Reference (Vd) Voltage Ref (Vd) U6-07 (005F) q-Axis ACR Output ACR(q) Output U6-08 (0060) d-Axis ACR Output ACR(d) Output OLV Output voltage reference (Vq) for the q-Axis. OLV Output voltage reference (Vd) for the d-Axis. OLV Displays the output value for current control relative to motor secondary current (q-Axis). 10 V: 200 Vrms 0.1 Vac <1> 10 V: 200 Vrms 0.1 Vac <1> 10 V: 200 Vrms <1> 0.1% OLV 110 V: 200 Displays the output value for current control relative to motor Vrms <1> secondary current (d-Axis). 0.1% <1> Values shown are specific to 200 V class drives. Double the values for 400 V class drives. Multiply the values by 2.875 for 600 V class drives. Note: Fault histories are not kept when CPF00, CPF01, CPF06, CPF24, oFA00, oFb00, oFC00, Uv1, Uv2, or Uv3 occur. u U7: CASE Monitors No. (Addr. Hex) U7-01 (0051) Name CASE Software Number LCD Display CASE Software # Description Displays the CASE software version number. Analog Output Level Unit No signal output available – Analog Output Level Unit u U9: Operation Status Monitors No. (Addr. Hex) U9-01 (1901) Name LCD Display Network PI Feedback Net PI Feedback U9-02 (1902) Network Activity iQ Net Activity U9-03 (1903) U9-04 (1904) Time to Alternate Time to Alternate Running Queue Number Running Queue No Description Displays the network PI feedback recognized by the iQpump MEMOBUS network. No signal output Dep. on available P1-02 Displays network traffic. A fluctuating number from 0 to 10000 denotes activity, while a relatively constant 0 denotes no activity. Displays the time remaining before a drive requests the alternation mode set in P9-04. Displays the position in the iQPump MEMOBUS Multiplex running queue. No signal output available No signal output available No signal output available <1> min – <1> Unit changes based on network status. <->: Drive cannot communicate to other drives <+>: Drive is a node on a network <M>: Drive is the master on an iQpump network. 334 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Appendix: C Standards Compliance This appendix explains the guidelines and criteria for maintaining CE and UL standards. C.1 C.2 EUROPEAN STANDARDS..................................................................................336 UL AND CSA STANDARDS................................................................................343 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 335 C.1 European Standards C.1 European Standards Figure C.1 CE Mark The CE mark indicates compliance with European safety and environmental regulations. It is required for engaging in business and commerce in Europe. European standards include the Machinery Directive for machine manufacturers, the Low Voltage Directive for electronics manufacturers, and the EMC guidelines for controlling noise. This drive displays the CE mark based on the EMC guidelines and the Low Voltage Directive. • Low Voltage Directive: 2006/95/EC • EMC Guidelines: 2004/108/EC Devices used in combination with this drive must also be CE certified and display the CE mark. When using drives displaying the CE mark in combination with other devices, it is ultimately the responsibility of the user to ensure compliance with CE standards. After setting up the device, verify that conditions meet European standards. Note: 600 V class drives (models 5oooooo) are not compliant with European Standards. u CE Low Voltage Directive Compliance This drive has been tested according to European standard IEC61800-5-1, and it fully complies with the Low Voltage Directive. To comply with the Low Voltage Directive, be sure to meet the following conditions when combining this drive with other devices: n Area of Use Do not use drives in areas with pollution higher than severity 2 and overvoltage category 3 in accordance with IEC664. n Factory Recommended Branch Circuit Protection Yaskawa recommends installing one of the following types of branch circuit protection to maintain compliance with UL508C. Semiconductor protective type fuses are preferred. Alternate branch circuit protection devices are also listed in Table C.1. NOTICE: If a fuse is blown or a Ground Fault Circuit Interrupter (GFCI) is tripped, check the wiring and the selection of peripheral devices to identify the cause. Contact Yaskawa before restarting the drive or the peripheral devices if the cause cannot be identified. Table C.1 Factory Recommended Drive Branch Circuit Protection Fuse Type Drive Model Manufacturer: Bussmann Model Fuse Ampere Rating (A) Three-Phase 200 V Class 336 2A0004 FWH-70B 70 2A0006 FWH-70B 70 2A0008 FWH-70B 70 2A0010 FWH-70B 70 2A0012 FWH-70B 70 2A0018 FWH-90B 90 2A0021 FWH-90B 90 2A0030 FWH-100B 100 2A0040 FWH-200B 200 2A0056 FWH-200B 200 2A0069 FWH-200B 200 2A0081 FWH-300A 300 2A0110 FWH-300A 300 2A0138 FWH-350A 350 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide C.1 European Standards Fuse Type Drive Model Manufacturer: Bussmann Model Fuse Ampere Rating (A) 2A0169 FWH-400A 400 2A0211 FWH-400A 400 2A0250 FWH-600A 600 2A0312 FWH-700A 700 2A0360 FWH-800A 800 2A0415 FWH-1000A 1000 Three-Phase 400 V Class 4A0002 FWH-40B 40 4A0004 FWH-50B 50 4A0005 FWH-70B 70 4A0007 FWH-70B 70 4A0009 FWH-90B 90 4A0011 FWH-90B 90 4A0018 FWH-80B 80 4A0023 FWH-100B 100 4A0031 FWH-125B 125 4A0038 FWH-200B 200 4A0044 FWH-250A 250 4A0058 FWH-250A 250 4A0072 FWH-250A 250 4A0088 FWH-250A 250 4A0103 FWH-250A 250 4A0139 FWH-350A 350 4A0165 FWH-400A 400 4A0208 FWH-500A 500 4A0250 FWH-600A 600 4A0296 FWH-700A 700 4A0362 FWH-800A 800 4A0414 FWH-800A 800 4A0515 FWH-1000A 1000 4A0675 FWH-1200A 1200 5A0003 <1> FWP-50B 50 5A0004 <1> FWP-50B 50 5A0006 <1> FWP-60B 60 5A0009 <1> FWP-60B 60 5A0011 <1> FWP-70B 70 5A0017 <1> FWP-100B 100 5A0022 <1> FWP-100B 100 5A0027 <1> FWP-125A 125 5A0032 <1> FWP-125A 125 5A0041 <1> FWP-175A 175 5A0052 <1> FWP-175A 175 5A0062 <1> FWP-250A 250 5A0077 <1> FWP-250A 250 5A0099 <1> FWP-250A 250 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide Standards Compliance Three-Phase 600 V Class 337 C C.1 European Standards Fuse Type Drive Model Manufacturer: Bussmann Model Fuse Ampere Rating (A) 5A0125 <1> FWP-350A 350 5A0145 <1> FWP-350A 350 5A0192 <1> FWP-600A 600 5A0242 <1> FWP-600A 600 <1> 600 V class drives are not compliant with European Standards. n Guarding Against Harmful Materials When installing IP00/Open Type enclosure drives, use an enclosure that prevents foreign material from entering the drive from above or below. n Grounding The drive is designed to be used in T-N (grounded neutral point) networks. If installing the drive in other types of grounded systems, contact your Yaskawa representative for instructions. u EMC Guidelines Compliance This drive is tested according to European standards EN61800-3: 2004. n EMC Filter Installation The following conditions must be met to ensure continued compliance with guidelines. Refer to EMC Filters on page 341 for EMC filter selection. Installation Method Verify the following installation conditions to ensure that other devices and machinery used in combination with this drive also comply with EMC guidelines. 1. 2. 3. 4. Install an EMC noise filter to the input side specified by Yaskawa for compliance with European standards. Place the drive and EMC noise filter in the same enclosure. Use braided shield cable for the drive and motor wiring, or run the wiring through a metal conduit. Keep wiring as short as possible. Ground the shield on both the drive side and the motor side. B A U/T1 D C U V/T2 V W/T3 W M E A – Drive B – 10 m max cable length between drive and motor C – Motor D – Metal conduit E – Ground wire should be as short as possible. Figure C.2 Installation Method 5. Make sure the protective earthing conductor complies with technical standards and local safety regulations. WARNING! Electrical Shock Hazard. Because the leakage current exceeds 3.5 mA in models 4A0414 to 4A1200, IEC 61800-5-1 states that either the power supply must be automatically disconnected in case of discontinuity of the protective earthing conductor, or a protective earthing conductor with a cross-section of at least 10 mm2 (Cu) or 16 mm2 (Al) must be used. Failure to comply may result in death or serious injury. 338 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide C.1 European Standards A C A – Braided shield cable B – Metal panel B C – Cable clamp (conductive) Figure C.3 Ground Area Connect a DC link choke to minimize harmonic distortion. Refer to DC Link Chokes for EN 61000-3-2 Compliance on page 342. Standards Compliance 6. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 339 C C.1 European Standards Three-Phase 200 V / 400 V Class A D B C K E J B F I H G A – Make sure the ground wire is grounded B – Grounding surface (remove any paint or sealant) C – Metal plate D – Enclosure panel E – Drive F – Motor cable (braided shield cable, max. 10 m) G – Motor H – Cable shield ground I – Cable clamp J – Ground plate (scrape off any visible paint) K – EMC noise filter Figure C.4 EMC Filter and Drive Installation for CE Compliance (Three-Phase 200 V / 400 V Class) 340 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide C.1 European Standards n EMC Filters Install the drive with the EMC filters listed in Table C.2 to comply with the EN61800-3 requirements. Table C.2 EN61800-3 Filters Filter Data (Manufacturer: Schaffner) Drive Model Type Rated Current (A) Weight (lb) Dimensions [W x D x H] (in) Y x X (in) Figure Three-Phase 200 V Class 2A0004 2A0006 FS5972-10-07 10 2.6 5.6 × 1.8 × 13.0 4.5 × 12.3 FS5972-18-07 18 2.9 5.6 × 1.8 × 13.0 4.5 × 12.3 2A0008 2A0010 2A0012 1 2A0018 2A0021 FS5972-35-07 35 4.6 8.1 × 2.0 × 14.0 6.9 × 13.2 FS5972-60-07 60 8.8 9.3 × 2.6 × 16.1 8.1 × 15.4 FS5972-100-35 100 7.5 3.5 × 5.9 × 13.0 2.6 × 10.0 FS5972-170-40 170 13.2 4.7 × 6.7 × 17.8 4.0 × 14.4 FS5972-250-37 250 25.8 5.1 × 9.5 × 24.0 3.5 × 19.6 FS5972-410-99 410 23.1 10.2 × 4.5 × 15.2 9.3 × 4.7 FS5972-600-99 600 24.3 10.2 × 5.3 × 15.2 9.3 × 4.7 2A0030 2A0040 2A0056 2A0069 2A0081 2A0110 2A0138 2A0169 2A0211 2A0250 2A0312 2A0360 2A0415 2 3 Three-Phase 400 V Class 4A0002 4A0004 4A0005 FS5972-10-07 10 2.7 5.6 × 1.8 × 13.0 4.5 × 12.3 FS5972-18-07 18 2.9 5.6 × 1.8 × 13.0 4.5 × 12.3 4A0007 4A0009 4A0011 1 4A0018 4A0023 FS5972-35-07 35 4.6 8.1 × 2.0 × 14.0 6.9 × 13.2 FS5972-60-07 60 8.8 9.3 × 2.6 × 16.1 8.0 × 15.4 FS5972-100-35 100 16.5 3.5 × 5.9 × 13.0 2.6 × 10.0 FS5972-170-35 170 10.4 4.7 × 6.7 × 17.8 4.0 × 14.4 FS5972-250-37 250 25.8 5.1 × 9.5 × 24.0 3.5 × 19.6 FS5972-410-99 410 23.1 10.2 × 4.5 × 15.2 9.3 × 4.7 FS5972-600-99 600 24.3 10.2 × 5.3 × 15.2 9.3 × 4.7 FS5972-800-99 800 69.4 11.8 × 6.3 × 28.2 10.8 × 8.3 4A0031 4A0038 4A0044 4A0058 4A0072 4A0088 4A0103 4A0139 2 4A0165 4A0208 4A0296 4A0362 4A0414 4A0515 4A0675 Standards Compliance 4A0250 3 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 341 C C.1 European Standards W W Y Y D X H H X D Figure 1 Figure 2 W X Y X H D Figure 3 Figure C.5 EMC Filter Dimensions n DC Link Chokes for EN 61000-3-2 Compliance Table C.3 DC Link Chokes for Harmonic Reduction Drive Model 2A0004 2A0006 DC Link Chokes Model 200 V Three-Phase Units Rating UZDA-B 5.4 A 8 mH 400 V Three-Phase Units 4A0002 4A0004 Note: 342 UZDA-B 3.2 A 28 mH DC link chokes are not required for other models to comply with EMC. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide C.2 UL and CSA Standards C.2 UL and CSA Standards u UL Standards Compliance The UL/cUL mark applies to products in the United States and Canada. It indicates that UL has performed product testing and evaluation, and determined that their stringent standards for product safety have been met. For a product to receive UL certification, all components inside that product must also receive UL certification. Figure C.6 UL/cUL Mark This drive is tested in accordance with UL standard UL508C and complies with UL requirements. The conditions described below must be met to maintain compliance when using this drive in combination with other equipment: n Installation Area Do not install the drive to an area greater than pollution degree 2 (UL standard). n Main Circuit Terminal Wiring Yaskawa recommends using closed-loop crimp terminals on all drive models. To maintain UL/cUL approval, UL-Listed closed-loop crimp terminals are specifically required when wiring the drive main circuit terminals on models 2A0110 to 2A0415, 4A0058 to 4A0675, and 5A0041 to 5A0242. Use only the tools recommended by the terminal manufacturer for crimping. Refer to Closed-Loop Crimp Terminal Size on page 343 for closed-loop crimp terminal recommendations. Closed-Loop Crimp Terminal Recommendations Yaskawa recommends crimp terminals made by JST and Tokyo DIP (or equivalent) for the insulation cap. Table C.4 matches the wire gauges and terminal screw sizes with Yaskawa-recommended crimp terminals, tools, and insulation caps. Refer to the appropriate Wire Gauge and Torque Specifications table for the wire gauge and screw size for your drive model. Place orders with a Yaskawa representative or the Yaskawa sales department. The closed-loop crimp terminal sizes and values listed in Table C.4 are Yaskawa recommendations. Wire gauge values shown in bold italic are the recommended values. Refer to local codes for proper selections. Table C.4 Closed-Loop Crimp Terminal Size Wire Gauge (AWG, kcmil) Drive Model R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 Screw Size Crimp Terminal Model Number Tool Machine No. Die Jaw YA-4 AD-900 YA-4 AD-900 Insulation Cap Model No. Code <1> TP-003 100-054-028 TP-005 100-054-029 TP-003 100-054-028 TP-005 100-054-029 TP-003 100-054-028 TP-005 100-054-029 2A0012 R2-4 M4 12 10 14 14 12 12 R2-4 M4 10 – 2A0018 14 12 12 10 M4 M4 10 2A0030 8 6 R5.5-4 R2-4 10 2A0021 R5.5-4 R5.5-4 R5.5-4 YA-4 AD-900 YA-4 AD-900 TP-005 100-054-029 AD-900 TP-005 100-054-029 AD-901 TP-008 100-054-031 AD-902 TP-014 100-054-033 R5.5-4 M4 8-4 14-NK4 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide YA-4 343 Standards Compliance 200 V Class 14 2A0004 2A0006 2A0008 2A0010 C C.2 UL and CSA Standards Wire Gauge (AWG, kcmil) Drive Model 2A0040 R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 8 8 6 6 6 2A0056 4 M8 3 3 2A0081 M4 M6 4 2A0069 Screw Size M8 Crimp Terminal Model Number 8-4 14-NK4 R14-6 R22-6 R22-8 R38-8 Tool Machine No. YA-4 YA-5 YA-5 Die Jaw Insulation Cap Model No. Code <1> AD-901 TP-008 100-054-031 AD-902 TP-014 100-054-033 AD-952 TP-014 100-051-261 AD-953 TP-022 100-051-262 AD-953 TP-022 100-051-263 AD-954 TP-038 100-051-264 R38-8 YA-5 AD-954 TP-038 100-051-264 R38-8 YA-5 AD-954 TP-038 100-051-264 1/0 R60-8 YA-5 AD-955 TP-060 100-051-265 1 R38-10 1/0 R60-10 TD-321, TD-311 TP-060 TD-323, TD-312 TP-080 TD-323, TD-312 TP-080 TD-324, TD-312 TP-100 100-051-269 TD-321, TD-311 TP-060 100-051-266 TD-323, TD-312 TP-080 100-054-036 TD-323, TD-312 TP-080 100-051-558 TD-324, TD-312 TP-100 100-051-560 TP-150 100-051-562 TP-150 100-051-273 TD-323, TD-312 TP-080 100-051-558 TD-324, TD-312 TP-100 100-051-560 150-L12 TD-325, TD-313 TP-150 100-051-562 100-L12 TD-324, TD-312 TP-100 100-051-560 150-L12 TD-325, TD-313 TP-150 100-051-562 TD-327, TD-314 TP-200 325-12 TD-328, TD-315 TP-325 100-051-277 150-L12 TD-325, TD-313 TP-150 100-051-562 TD-327, TD-314 TP-200 TD-328, TD-315 TP-325 2 3 2 2A0110 M8 1 2A0138 M10 2/0 2/0 70-10 – 3/0 2A0169 2A0250 70-10 M10 R100-10 1/0 × 2P R60-10 M10 2/0 × 2P 70-10 3/0 × 2P 80-L12 4/0 × 2P 100-L12 – 250 × 2P 250 – M12 3/0 × 2P 3/0 × 2P 4/0 × 2P 4/0 × 2P M12 300 × 2P 4/0 × 2P 250 × 2P 250 × 2P 300 × 2P 2A0360 M12 350 × 2P 400 × 2P 2A0415 600 × 2P 250 × 2P – 300 × 2P 300 × 2P 350 × 2P 350 × 2P 400 × 2P 500 × 2P 600 × 2P 344 YF-1 YET-300-1 TD-325, TD-313 100-L12 180-L12 YF-1 YET-300-1 YF-1 YET-300-1 200-L12 500 × 2P 600 YF-1 YET-300-1 80-L12 250 × 2P 4/0 × 2P 150-L12 YF-1 YET-300-1 R150-12 300 2A0312 80-10 4/0 2A0211 YF-1 YET-300-1 M12 180-L12 200-L12 325-12 YF-1 YET-300-1 100-061-114 100-051-266 100-054-036 100-054-036 100-051-267 100-066-688 100-051-564 100-066-688 100-051-564 100-051-277 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide C.2 UL and CSA Standards Wire Gauge (AWG, kcmil) Drive Model R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 Screw Size Crimp Terminal Model Number Tool Machine No. Insulation Cap Model No. Code <1> TP-003 100-054-028 TP-005 100-054-029 TP-003 100-054-028 TP-005 100-054-029 AD-900 TP-005 100-054-029 100-054-031 Die Jaw 400 V Class 4A0002 4A0004 4A0005 4A0007 4A0009 4A0011 14 R2-4 12 M4 10 14 14 12 12 12 M4 8 TP-008 TP-014 100-054-033 10 R5.5-4 AD-900 TP-005 100-054-029 100-054-031 M4 10 M5 6 8 8 6 6 6 M6 4 6 M8 4 4 4A0072 M5 M8 3 8-4 YA-4 AD-902 8 4A0058 R5.5-4 AD-901 – 4A0044 AD-900 14-NK4 6 4A0038 YA-4 6 8 4A0031 AD-900 R5.5-4 10 4A0023 YA-4 R2-4 M4 10 4A0018 R5.5-4 8-4 YA-4 AD-901 TP-008 14-NK4 AD-902 TP-014 100-054-033 R5.5-5 AD-900 TP-005 100-054-030 AD-901 TP-008 100-054-032 R8-5 YA-4 R14-5 AD-902 TP-014 100-054-034 R8-5 AD-901 TP-008 100-054-032 R14-5 R14-6 R22-6 R14-8 R22-8 YA-4 YA-5 YA-5 AD-902 TP-014 100-054-034 AD-952 TP-014 100-051-261 AD-953 TP-022 100-051-262 AD-952 TP-014 100-054-035 AD-953 TP-022 100-051-263 AD-953 TP-022 100-051-263 AD-954 TP-038 100-051-264 AD-954 TP-038 100-051-264 AD-955 TP-060 100-051-265 AD-954 TP-038 100-051-264 R60-8 AD-955 TP-060 100-051-265 R60-10 TD-321, TD-311 TP-060 100-051-266 TD-323, TD-312 TP-080 TD-324, TD-312 TP-100 100-051-269 TD-323, TD-312 TP-080 100-051-267 TD-324, TD-312 TP-100 100-051-269 TD-224, TD-212 TP-038 100-051-556 TD-227, TD-214 TP-080 100-051-557 TD-228, TD-214 TP-100 100-051-269 TD-229, TD-215 TP-150 100-051-272 R22-8 R38-8 YA-5 3 M8 1 1/0 1 1 1/0 1/0 M8 1/0 4A0139 2/0 2/0 3/0 3/0 M10 R38-8 70-10 80-10 4/0 R100-10 3/0 80-10 4A0165 M10 4/0 R100-10 2 × 2P 3/0 × 2P 80-L10 M10 4/0 250 300 YA-5 YF-1 YET-300-1 YF-1 YET-300-1 38-L10 1 × 2P 4A0208 YA-5 R60-8 2 4A0103 R38-8 R100-10 R150-10 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide YF-1 YET-150-1 100-054-036 100-051-267 345 Standards Compliance 2 4A0088 C C.2 UL and CSA Standards Wire Gauge (AWG, kcmil) Drive Model R/L1, S/L2, T/L3 U/T1, V/T2, W/T3 1 × 2P – 80-L10 4/0 × 2P 100-L10 M10 R150-10 350 180-10 400 200-10 325-10 TD-224, TD-212 TP-038 100-051-556 TD-227, TD-214 TP-080 100-051-557 TD-228, TD-214 TP-100 100-051-559 TD-229, TD-215 TP-150 100-051-561 TP-150 100-051-272 TD-327, TD-314 TP-200 TD-328, TD-315 TP-325 100-051-565 100-066-687 100-051-563 TD-323, TD-312 TP-080 100-051-558 4/0 × 2P 100-L12 TD-324, TD-312 TP-100 100-051-560 TD-325, TD-313 TP-150 100-051-562 150-L12 300 × 2P – 350 × 2P M12 180-L12 YF-1 YET-300-1 100-066-688 TD-327, TD-314 TP-200 325-12 TD-328, TD-315 TP-325 100-051-277 3/0 × 2P 80-L12 TD-323, TD-312 TP-080 100-051-558 4/0 × 2P 100-L12 TD-324, TD-312 TP-100 100-051-560 TD-325, TD-313 TP-150 100-051-562 TD-327, TD-314 TP-200 TD-328, TD-315 TP-325 100-051-277 TD-324, TD-312 TP-100 100-051-560 TD-325, TD-313 TP-150 100-051-562 TD-323, TD-312 TP-080 100-051-558 TD-324, TD-312 TP-100 100-051-560 TD-325, TD-313 TP-150 100-051-562 TD-324, TD-312 TP-100 100-051-560 TD-325, TD-313 TP-150 100-051-562 – 180-12 400 R200-12 500 600 250 × 2P M12 300 × 2P 150-L12 350 × 2P 180-L12 400 × 2P 200-L12 500 4/0 × 2P 100-L12 M12 250 × 2P 150-L12 300 × 2P 3/0 × 4P 3/0 × 4P 4/0 × 4P 4/0 × 4P M12 100-L12 YF-1 YET-300-1 150-L12 300 × 2P 4/0 × 4P 300 × 4P YF-1 YET-300-1 80-L12 250 × 4P 250 × 4P YF-1 YET-300-1 325-12 600 4A0675 YF-1 YET-300-1 Code <1> Die Jaw 80-L12 350 4A0515 YF-1 YET-150-1 Insulation Cap Model No. 3/0 × 2P 250 × 2P 4A0414 Machine No. 150-L10 300 600 4A0362 Tool 38-L10 500 4A0296 Crimp Terminal Model Number 3/0 × 2P 250 × 2P 4A0250 Screw Size 100-L12 M12 150-L12 YF-1 YET-300-1 100-066-689 100-051-275 100-066-688 100-051-564 <1> Codes refer to a set of three crimp terminals and three insulation caps. Prepare input and output wiring using two sets for each connection. Example 1: Models with 300 kcmil for both input and output require one set for input terminals and one set for output terminals, so the user should order two sets of [100-051-272]. Example 2: Models with 4/0 AWG × 2P for both input and output require two sets for input terminals and two sets for output terminals, so the user should order four sets of [100-051-560]. Note: 346 Use crimp insulated terminals or insulated shrink tubing for wiring connections. Wires should have a continuous maximum allowable temperature of 75 °C 600 Vac UL-approved vinyl-sheathed insulation. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide C.2 UL and CSA Standards Input Fuse Installation Yaskawa recommends installing one of the following types of branch circuit protection to maintain compliance with UL508C. Semiconductor protective type fuses are preferred. Alternate branch circuit protection devices are also listed in Table C.5. <1> Time Delay Fuse Rating Amps <2> Non-time Delay Fuse Rating Amps <3> Bussman Semiconductor Fuse Rating (Fuse Ampere) <4> 3.9 7.3 8.8 10.8 13.9 18.5 24 200 V Class 15 15 15 20 25 35 45 6.25 12 15 17.5 20 30 40 10 20 25 30 40 50 70 FWH-70B (70) FWH-70B (70) FWH-70B (70) FWH-70B (70) FWH-70B (70) FWH-90B(90) FWH-90B(90) 10 15 20 25 30 40 50 60 75 100 125 37 52 68 80 96 111 136 164 200 271 324 60 100 125 150 175 200 250 300 400 500 600 60 90 110 125 150 175 225 250 350 450 500 110 150 200 225 275 300 400 450 600 800 800 FWH-100B (100) FWH-200B (200) FWH-200B (200) FWH-200B (200) FWH-300A (300) FWH-300A (300) FWH-350A (350) FWH-400A (400) FWH-400A (400) FWH-600A (600) FWH-700A (700) 150 394 700 600 1000 <5> FWH-800A (800) FWH-1000A (1000) Drive Model Nominal Output Power HP AC Drive Input Amps 2A0004 2A0006 2A0008 2A0010 2A0012 2A0018 2A0021 0.75 1 - 1.5 2 3 3 5 7.5 2A0030 2A0040 2A0056 2A0069 2A0081 2A0110 2A0138 2A0169 2A0211 2A0250 2A0312 2A0360 2A0415 175 MCCB Rating Amps 471 900 800 1400 <5> 3.5 7.5 10 12 15 20 35 40 60 75 90 100 110 150 175 225 250 350 400 500 6 12 17.5 20 25 40 60 70 110 125 150 150 200 250 300 400 500 600 700 800 FWH-40B (40) FWH-50B (50) FWH-70B (70) FWH-70B (70) FWH-90B (90) FWH-90B (90) FWH-80B (80) FWH-100B (100) FWH-125B (125) FWH-200B (200) FWH-250A (250) FWH-250A (250) FWH-250A (250) FWH-250A (250) FWH-250A (250) FWH-350A (350) FWH-400A (400) FWH-500A (500) FWH-600A (600) FWH-700A (700) 600 1000 <5> FWH-800A (800) 4A0002 4A0004 4A0005 4A0007 4A0009 4A0011 4A0018 4A0023 4A0031 4A0038 4A0044 4A0058 4A0072 4A0088 4A0103 4A0139 4A0165 4A0208 4A0250 4A0296 1 2 3 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 2.1 4.3 5.9 8.1 9.4 14 20 24 38 44 52 58 71 86 105 142 170 207 248 300 400 V Class 15 15 15 15 15 25 40 45 75 75 100 100 125 150 200 250 300 400 450 600 4A0362 300 346 600 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 347 Standards Compliance Table C.5 Factory Recommended AC Drive Branch Circuit Protection (Normal Duty) C C.2 UL and CSA Standards MCCB Rating Amps Delay Time Delay Fuse Non-time Fuse Rating <2> Rating Amps Amps <3> Bussman Semiconductor Fuse Rating (Fuse Ampere) <4> Drive Model Nominal Output Power HP AC Drive Input Amps 4A0414 350 410 800 700 1200 <5> FWH-800A (800) 4A0515 400 - 450 465 900 800 1350 <5> FWH-1000A (1000) 4A0675 500 - 600 657 1200 1100 <5> 1800 <5> FWH-1200A (1200) 5A0003 5A0004 5A0006 5A0009 5A0011 5A0017 5A0022 5A0027 2 3 5 7.5 10 15 20 25 3.6 5.1 8.3 12 16 23 31 38 600 V Class 15 15 15 20 30 40 60 75 6.25 8 12 20 25 40 50 60 10 15 20 35 45 60 90 110 FWP-50B (50) FWP-50B (50) FWP-60B (60) FWP-60B (60) FWP-70B (70) FWP-100B (100) FWP-100B (100) FWP-125A (125) 5A0032 5A0041 5A0052 5A0062 5A0077 5A0099 5A0125 5A0145 5A0192 5A0242 30 40 50 60 75 100 125 150 200 250 45 44 54 66 80 108 129 158 228 263 75 75 100 125 150 175 225 300 400 500 75 75 90 110 125 175 225 275 350 450 125 125 150 175 225 300 350 450 600 700 FWP-125A (125) FWP-175A (175) FWP-175A (175) FWP-250A (250) FWP-250A (250) FWP-250A (250) FWP-350A (350) FWP-350A (350) FWP-600A (600) FWP-600A (600) <1> <1> <2> <3> <4> Maximum MCCB Rating is 15 A, or 200 % of drive input current rating, whichever is larger. MCCB voltage rating must be 600 VAC or greater. Maximum Time Delay fuse is 175% of drive input current rating. This covers any Class CC, J or T class fuse. Maximum Non-time Delay fuse is 300% of drive input current rating. This covers any CC, J or T class fuse. When using semiconductor fuses, Bussman FWH and FWP are required for UL compliance. Select FWH for 200 V Class and 400 V Class models and FWP fuses for 600 V models. <5> Class L fuse is also approved for this rating. 348 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide C.2 UL and CSA Standards n Low Voltage Wiring for Control Circuit Terminals Wire low voltage wires with NEC Class 1 circuit conductors. Refer to national state or local codes for wiring. The external power supply shall be a UL listed Class 2 power supply source or equivalent only. Table C.6 Control Circuit Terminal Power Supply Input / Output Terminal Signal Digital inputs Analog inputs / outputs S1 to S8, SC +V, A1, A2, A3, AC, AM, FM Power Supply Specifications Use the internal LVLC power supply of the drive. Use class 2 for external power supply. Use the internal LVLC power supply of the drive. Use class 2 for external power supply. n Drive Short Circuit Rating The drive is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical Amperes, 240 Vac maximum (200 V Class), 480 Vac maximum (400 V Class), and 600 Vac maximum (600 V Class) when protected by Bussmann Type FWH or FWP fuses as specified in Factory Recommended Branch Circuit Protection on page 336. u CSA Standards Compliance Figure C.7 CSA Mark n CSA for Industrial Control Equipment The drive is CSA-certified as Industrial Control Equipment Class 3211. Specifically, the drive is certified to: CAN/CSA C22.2 No. 04-04 and CAN/CSA C22.2 No.14-05. u Drive Motor Overload Protection Set parameter E2-01 (motor rated current) to the appropriate value to enable motor overload protection. The internal motor overload protection is UL listed and in accordance with the NEC and CEC. n E2-01: Motor Rated Current Standards Compliance Setting Range: Model-dependent Default Setting: Model-dependent Parameter E2-01 protects the motor when parameter L1-01 is not set to 0. The default for L1-01 is 1, which enables protection for standard induction motors. If Auto-Tuning has been performed successfully, the motor data entered to T1-04 is automatically written to parameter E2-01. If Auto-Tuning has not been performed, manually enter the correct motor rated current to parameter E2-01. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 349 C C.2 UL and CSA Standards n L1-01: Motor Overload Protection Selection The drive has an electronic overload protection function (oL1) based on time, output current, and output frequency that protects the motor from overheating. The electronic thermal overload function is UL-recognized, so it does not require an external thermal relay for single motor operation. This parameter selects the motor overload curve used according to the type of motor applied. Table C.7 Overload Protection Settings Setting 0 Disabled 1 2 3 6 Description Disabled the internal motor overload protection of the drive. Selects protection characteristics for a standard self-cooled motor with limited cooling capabilities Standard fan-cooled motor (60 Hz default) when running below the rated speed. The motor overload detection level (oL1) is automatically reduced when running below the motor rated speed. Selects protection characteristics for a motor with self-cooling capability within a speed range of Drive duty motor with a speed range of 1:10 10:1. The motor overload detection level (oL1) is automatically reduced when running below 1/10 of the motor rated speed. Selects protection characteristics for a motor capable of cooling itself at any speed including zero Vector motor with a speed range of 1:100 speed (externally cooled motor). The motor overload detection level (oL1) is constant over the entire speed range. Selects protection characteristics for a standard self-cooled motor with limited cooling capabilities when running below the rated speed. The motor overload detection level (oL1) is automatically reduced when running below the motor rated speed. Standard fan-cooled motor (50 Hz) When connecting the drive to more than one motor for simultaneous operation, disable the electronic overload protection (L1-01 = 0) and wire each motor with its own motor thermal overload relay. Enable motor overload protection (L1-01 ≠ 0) when connecting the drive to a single motor, unless another motor overload preventing device is installed. The drive electronic thermal overload function causes an oL1 fault, which shuts off the output of the drive and prevents additional overheating of the motor. The motor temperature is continually calculated while the drive is powered up. n L1-02: Motor Overload Protection Time Setting Range: 0.1 to 5.0 min Factory Default: 1.0 min Parameter L1-02 determines how long the motor is allowed to operate before the oL1 fault occurs when the drive is running a hot motor at 60 Hz and at 150% of the full load amp rating (E2-01) of the motor. Adjusting the value of L1-02 can shift the set of oL1 curves up the y axis of the diagram below, but will not change the shape of the curves. Time (min) 10 7 3 Cold Start 1 0.4 Hot Start 0.1 0 100 150 200 Motor Current (%) (E2-01=100 %) Figure C.8 Motor Overload Protection Time 350 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide C.2 UL and CSA Standards u Precautionary Notes on External Heatsink (IP00/Open Type Enclosure) When mounting the drive heatsink out the back of an enclosure, UL compliance requires covering exposed capacitors in the main circuit to prevent injury to surrounding personnel. The portion of the external heatsink that projects out can be protected with the enclosure or with the appropriate capacitor cover after completing drive installation. The drive models listed in Table C.8 require additional protection by means of a capacitor cover. Order capacitor covers from a Yaskawa representative or directly from the Yaskawa sales department. Refer to Figure C.9 for a detailed description of the capacitor cover parts. Table C.8 Capacitor Cover Drive Model 2A0110 2A0138 2A0169 2A0211 2A0250 2A0312 2A0360 2A0415 4A0058 4A0072 4A0088 4A0103 4A0139 4A0165 4A0208 4A0250 4A0296 4A0362 4A0414 4A0515 4A0675 5A0041 5A0052 5A0062 5A0077 5A0099 5A0125 5A0145 5A0192 5A0242 Code Number 100-061-273 100-061-274 Model ECAT31875-11 ECAT31876-11 100-061-275 ECAT31877-11 100-061-277 ECAT31726-11 100-061-278 ECAT31698-11 100-061-273 100-061-274 ECAT31875-11 ECAT31876-11 100-061-276 ECAT31878-11 100-061-275 ECAT31877-11 100-061-277 ECAT31726-11 100-061-278 ECAT31698-11 100-061-279 ECAT31740-11 100-061-280 ECAT31746-11 100-061-274 ECAT31876-11 100-061-275 ECAT31877-11 100-061-277 ECAT31726-11 100-061-278 ECAT31698-11 Standards Compliance <1> Requires two sets. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 351 C C.2 UL and CSA Standards A B C E D A – Drive (outside panel) B – Drive (inside panel) C – Opening to capacitors D – Installation screws E – Capacitor cover Figure C.9 Capacitor Cover 352 YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide This Page Intentionally Blank YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide 353 Revision History The revision dates and the numbers of the revised manuals appear on the bottom of the back cover. Date of Publication November 2012 354 Revision Number - Section Revised Content - First Edition. This manual supports drive software version PRG: 8550. YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide iQpump1000 AC Drive Intelligent Pump Controller Quick Start Guide YASKAWA AMERICA, INC. 2121 Norman Drive South, Waukegan, IL 60085, U.S.A. Phone: (800) YASKAWA (927-5292) or 1-847-887-7000 Fax: 1-847-887-7310 http://www.yaskawa.com DRIVE CENTER (INVERTER PLANT) 2-13-1, Nishimiyaichi, Yukuhashi, Fukuoka, 824-8511, Japan Phone: 81-930-25-3844 Fax: 81-930-25-4369 http://www.yaskawa.co.jp YASKAWA ELECTRIC CORPORATION New Pier Takeshiba South Tower, 1-16-1, Kaigan, Minatoku, Tokyo, 105-6891, Japan Phone: 81-3-5402-4502 Fax: 81-3-5402-4580 http://www.yaskawa.co.jp YASKAWA ELÉTRICO DO BRASIL LTDA. Avenda Fagundes Filho, 620 Bairro Saude, São Paulo, SP04304-000, Brasil Phone: 55-11-3585-1100 Fax: 55-11-5581-8795 http://www.yaskawa.com.br YASKAWA EUROPE GmbH Hauptstrasse 185, 65760 Eschborn, Germany Phone: 49-6196-569-300 Fax: 49-6196-569-398 http://www.yaskawa.eu.com YASKAWA ELECTRIC UK LTD. 1 Hunt Hill Orchardton Woods, Cumbernauld, G68 9LF, United Kingdom Phone: 44-1236-735000 Fax: 44-1236-458182 http://www.yaskawa.co.uk YASKAWA ELECTRIC KOREA CORPORATION 9F, Kyobo Securities Bldg., 26-4, Yeouido-dong, Yeongdeungpo-gu, Seoul, 150-737, Korea Phone: 82-2-784-7844 Fax: 82-2-784-8495 http://www.yaskawa.co.kr YASKAWA ELECTRIC (SINGAPORE) PTE. LTD. 151 Lorong Chuan, #04-01, New Tech Park, 556741, Singapore Phone: 65-6282-3003 Fax: 65-6289-3003 http://www.yaskawa.com.sg YASKAWA ELECTRIC (SHANGHAI) CO., LTD. 12F, Carlton Bld., No.21 HuangHe Road, HuangPu District, Shanghai 200003, China Phone: 86-21-5385-2200 Fax: 86-21-5385-3299 http://www.yaskawa.com.cn YASKAWA ELECTRIC (SHANGHAI) CO., LTD. BEIJING OFFICE Room 1011, Tower W3 Oriental Plaza, No. 1 East Chang An Ave., Dong Cheng District, Beijing, 100738, China Phone: 86-10-8518-4086 Fax: 86-10-8518-4082 YASKAWA ELECTRIC TAIWAN CORPORATION 9F, 16, Nanking E. Rd., Sec. 3, Taipei, 104, Taiwan Phone: 886-2-2502-5003 Fax: 886-2-2505-1280 YASKAWA ELECTRIC INDIA PRIVATE LIMITED #17/A Electronics City, Hosur Road Bangalore 560 100 (Karnataka), India Phone: 91-80-4244-1900 Fax: 91-80-4244-1901 http://www.yaskawaindia.in YASKAWA AMERICA, INC. In the event that the end user of this product is to be the military and said product is to be employed in any weapons systems or the manufacture thereof, the export will fall under the relevant regulations as stipulated in the Foreign Exchange and Foreign Trade Regulations. Therefore, be sure to follow all procedures and submit all relevant documentation according to any and all rules, regulations and laws that may apply. Specifications are subject to change without notice for ongoing product modifications and improvements. © 2012 YASKAWA AMERICA, INC. All rights reserved. MANUAL NO. TOEP YAIP1W 01A Published in U.S.A November 2012 12-11 ">
/
Изтегляне
Само приятелско напомняне. Можете да видите документа точно тук. Но най-важното е, че нашият AI вече го е прочел. Той може да обясни сложни неща на прости термини, да отговори на вашите въпроси на всеки език и да ви помогне бързо да навигирате дори в най-дългите или най-сложните документи.
Реклама