ADEMCO LYNXR-IE Security Systems Installation and Setup Guide


Add to my manuals
72 Pages

advertisement

ADEMCO LYNXR-IE Security Systems Installation and Setup Guide | Manualzz

K14114-5 2/09 Rev. A

ADEMCO LYNXR-IE

Systems

Installation and Setup Guide

ARMED

READY

ADD

STAY

DELETE

AUX

SELECT

OFF

ESCAPE

AWAY

1

2

LIGHTS ON

7

RECORD

4

LIGHTS OFF

CODE

0

8

VOLUME

5

TEST

PLAY

6

BYPASS

9

CHIME

#

STATUS NO DELAY

FUNCTION

3

- 2 -

Table of Contents

SYSTEM FEATURES ..................................................................................................................................4

MOUNTING THE CONTROL.....................................................................................................................5

WIRING CONNECTIONS...........................................................................................................................6

CONNECTING/CONFIGURING COMMUNICATIONS DEVICES ........................................................8

AC POWER AND BACKUP BATTERY......................................................................................................9

INSTALLING WIRELESS ZONES...........................................................................................................11

MECHANICS OF PROGRAMMING ........................................................................................................13

ZONE RESPONSE TYPE DEFINITIONS ...............................................................................................15

DATA FIELD DESCRIPTIONS ................................................................................................................17

✻56 ENHANCED ZONE PROGRAMMING MODE ................................................................................25

✻80 DEVICE PROGRAMMING MENU MODE ......................................................................................30

✻81 ZONE LIST MENU MODE................................................................................................................33

✻83 ENHANCED SEQUENTIAL MODE ................................................................................................34

✻84 ASSIGN ZONE VOICE DESCRIPTORS ..........................................................................................37

✻85 RECORD CUSTOM VOICE DESCRIPTORS...................................................................................39

ENROLLING THE CSK800HF MONODIRECTINAL KEYPAD ...........................................................40

VOICE PROMPT PROGRAMMING.........................................................................................................42

REMOTE PROGRAMMING/CONTROL (DOWNLOADING) ................................................................46

SYSTEM OPERATION..............................................................................................................................48

TESTING THE SYSTEM ..........................................................................................................................54

SYSTEM COMMUNICATION ..................................................................................................................55

TROUBLESHOOTING GUIDE ................................................................................................................57

PROGRAMMING DEFAULT TABLES....................................................................................................60

LIMITATIONS OF THIS SYSTEM STATEMENT..................................................................................63

SPECIFICATIONS.....................................................................................................................................64

CONTACTING TECHNICAL SUPPORT.................................................................................................65

INDEX.........................................................................................................................................................67

SUMMARY OF CONNECTIONS DIAGRAM ..........................................................................................71

WARRANTY INFORMATION .................................................................................................. Back Cover

- 3 -

LYNXR-IE Installation and Setup Guide

System Features

!

LYNXR-IE is not intended for Household Fire applications unless a 24-hour backup battery (P/N

LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed.

The LYNXR-IE control is a self-contained, rechargeable wireless control/communicators that feature easy installation and usage. A built-in speaker provides voice annunciation of system status along with voice descriptors of each zone. An internal module (if provided) allows the LYNXR-IE to communicate with the

Central Station via the Internet. The following illustration highlights the main features of this system.

ZONES and DEVICES

• Up to 24 wireless zones

(SECOM V2 GY Receivers)

• Up to 16 wireless button zones

• Up to 8 Powerline Carrier Devices

• Supports wireless keypads

FEATURES

• Real-time Clock display and Fixed-Word display

• Message Center (for user recorded messages)

• Voice announcement of system and zone status

• Voice chime

• Alarm Clock

• Reminder

• X10 Scheduling

• Latch Key Reports

• Automatic Stay Arming

• Remote Phone Control

• “Follow Me” Reminder

SYSTEM POWER

• Primary Power: K10145EX Plug-in

Transformer, 220VAC to 9VAC,

25VA output

• Backup battery: Rechargeable nickel-metal hydride battery pack rated at 7.7Vdc.

8 USER CODES

• Installer code

• Master code

• 5 Secondary codes

• Duress code

• 3 Panic functions

COMMUNICATION

• ADEMCO Contact ID

• Internet Central

Station Communication

• GSM Cellular Central

Station Communication

ARMED

READY

DELETE

AUX

SELECT

ADD

STAY

OFF

ESCAPE

AWAY

1 2

RECORD

4

LIGHTS ON

7

LIGHTS OFF

VOLUME

5

TEST

8

CODE

0

PLAY

6

BYPASS

9

CHIME

#

STATUS NO DELAY

FUNCTION

3

ALARM OUTPUT

• Built-in sounder

• Piezo output

(30mA max.)

• Bell output

(120mA max.)

• Steady output for burglary/panic

• Temporal pulse output for fire alarms

• Long Range

Radio/Audio alarm verification

PROGRAMMING

• Options stored in EEROM

• Can be uploaded, downloaded or controlled via IBM-compatible computer using Compass downloader software and specified

HAYES modem

• Voice Prompt programming mode

OTHER FEATURES

• Exit error feature (detects difference between an actual alarm and exit alarm caused by leaving a door open after the exit delay expires)

• Event log stores up to 84 events

• Macro/Manual Message

• RF Jam Detection

• Remote Phone Control

• Case Tamper

SPECIAL FEATURES

• Two-way voice communication

• Speaker phone operation

- 4 -

LYNXR-IE Installation and Setup Guide

Mounting the Control

Wall Mounting

The illustration below shows the front assembly separated from the back plate.

!

DO NOT disconnect the ribbon cable from the terminal strip board. Disconnect the cable only from the front assembly board.

1. Release the front assembly from the back plate by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver.

2. Once these tabs have been released, insert the screwdriver in the side of the case and release the side locking tabs by gently twisting.

3. Carefully disconnect the ribbon cable from the front assembly, leaving the ribbon

cable connected to the terminal block

PC board. The back plate contains the terminal block for making wiring connections.

4. Mount the back plate to a sturdy wall, feeding the field wiring through the appropriate openings in the back plate.

5. After wiring connections are made, carefully reconnect the ribbon cable to the front assembly PC board connector

(properly aligning the red wire).

6. Snap the front assembly to the back plate so it is secured by the locking tabs.

LOCKING

TABS

LOCKING TABS

DISCONNECT

THIS END ONLY!

RED WIRE

MARKING

LOCKING

TABS

07000-003-V1

Desktop Mounting

For desktop use the optional mounting base (model LYNX-DM, purchased separately) must be used.

1. Slide the control panel onto the mounting base locking tabs.

2. Bring all wiring through the bottom of the mounting base, using one of the three wire entry locations, before making connections to the control panel.

3. Use tie-wraps to secure the wiring to the built-in wire loops as needed. Use the two supplied screws to secure the control panel to the mounting base.

DELETE

AUX

SELECT

ADD

STAY

OFF

ESCAPE

AWAY

WIRE ENTRY

KNOCKOUT

(1 of 3)

01009-004-V1

- 5 -

LYNXR-IE Installation and Setup Guide

Wiring Connections

Wiring Overview

The following summarizes the connections required. Refer to the Wiring Connections paragraph and the

Summary of Connections diagram on the inside back cover when making connections.

TELEPHONE

CONNECTIONS

LOCAL SOUNDER

DISABLE JUMPER

TERMINAL

STRIP

(FUTURE USE)

ALARMNET LRR/IP

COMMUNICATION PORT

SUPER HIGH CAPACITY

BATTERY CONNECTOR

STANDARD AND HIGH CAPACITY

BATTERY CONNECTOR

09006-005-V0

TO

HANDSET

PHONE

LINE

INCOMING

PHONE

LINE

EARTH

GROUND

RJ11

8

POS

JACK

WARNING:

TO PREVENT

RISK OF SHOCK

DISCONNECT

TELEPHONE LINE

AT TELECOM

JACK BEFORE

SERVICING

THIS UNIT.

1

PHONE

ALL OUTPUT CIRCUITS ARE POWER LIMITED.

2 3 4 5

TIP RING TIP RING

6

FUTURE

USE

7

( )

8

GND

9

SOUNDERS

PLCD

10

11 12 13 14 15

( ) (+) ( ) (+) DATA SYNC

OUT IN

AC

16

(FUTURE USE)

STANDARD/HIGH

CAPACITY BATTERY

CONNECTOR

SUPER HIGH CAPACITY

BATTERY CONNECTOR

ALARMNET LRR/IP

COMMUNICATIONS PORT

LOCAL SOUNDER DISABLE

SHUNT REMOVE TO DISABLE

THE LYNXR-IE CONTROL IS COMPATIBLE WITH

THE FOLLOWING INTEGRAL RECHARGEABLE

BATTERY PACKS:

P/N LYNXRCHKIT-SC

P/N LYNXRCHKIT-HC

P/N LYNXRCHKIT-SHA

REPLACE EVERY FOUR YEARS

INCOMING

TELEPHONE

LINE

PREMISES

TELEPHONE

EARTH

GROUND

WEEKLY TESTING IS

REQUIRED TO ENSURE

PROPER OPERATION

OF THIS SYSTEM

FUTURE

USE

PIEZO

SIREN

6-14VDC

30mA max.

6-14VDC

120mA max.

(e.g. WAVE2EX)

NOTE

USE ONLY THE K10145EX

TRANSFORMER PROVIDED

LYNXR-IE Wiring Connections

- 6 -

AC

AC

K10145EX

TRANSFORMER

9VAC, 25VA

SYNC

COM

X10

ONLY

CONNECTIONS

DATA

09006-009-V0

LYNXR-IE Installation and Setup Guide

Wiring Connections

1. Make Earth Ground Connection

-

The designated earth ground terminal (1) must be terminated in a good earth ground for the lightning transient protective devices in this product to be effective. The following are examples of good earth grounds available at most installations:

Metal Cold Water Pipe - Secure a non-corrosive metal strap (copper is recommended) to the pipe that is electrically connected and secured to which the ground lead is electrically connected and secured.

AC Power Outlet Ground - Available from 220VAC power outlets only. To test the integrity of the ground terminal, use a three-wire circuit tester with neon lamp indicators, available at most electrical supply stores. a. Connect terminal 1 to a good earth ground.

2. Make Phone Line Connections - For local or full line seizure, proceed to the appropriate steps below.

Local Seizure

a. Connect the incoming phone line to either the

8-position jack or terminals 2 (TIP) and 3

(RING) on the Lynx.

INCOMING

PHONE LINE

RING

TIP b. Connect the handset phone lines to either the

RJ11 jack or terminals 4 (TIP) and 5 (RING).

RED

3

4 5

6

GREEN

RJ31X

RING

TIP

TO

PREMISES PHONES

Full Line Seizure: The control must be placed in series with the incoming phone line. Plugging the Direct Connect Cord directly into the RJ31X jack, allows the control to seize the phone line when an alarm occurs and normal phone line usage by the premises phones if the plug needs to be removed.

GREY

2

1

7

8 BROWN

DIRECT

CONNECT

CORD c. Cut the incoming RING and TIP phone lines

(typically red and green, respectively) and connect them to RJ31X terminals 4 (red) and

5 (green). d. Connect the premises end of the cut RING and TIP wires to RJ31X terminals 1 (grey) and

8 (brown) respectively. e. Wire the flying leads of a Direct Connect Cord to the control’s phone terminals as shown in the diagram or plug into the 8-position jack.

TIP RING TIP RING

INCOMING

PHONE LINE

TO

PREMISES

PHONES

8-POSITION

JACK

f. Plug the Direct Connect Cord into the RJ31X jack.

01000-008-V0

Full Line Seizure Connections

LOCAL SOUNDER DISABLE: The Master Keypad’s built-in piezo sounder can be disabled by removing the shorting jumper (shunt) on the terminal board. If disabled, however, no sounding will occur upon AC loss, since the external sounder does not operate when AC power is lost.

3. Make External Sounder Connections - The control panel supports either a 6-14VDC piezo sounder (30mA max.) or

6-14VDC bell (120mA max.; e.g. ADEMCO WAVE2EX). a. Connect a piezo sounder to terminals 10 (+) and 11 (–); OR a bell to terminals 11 (–) and 12 (+).

4. Disable Local Sounder Option - If required the Master Keypad’s built-in piezo sounder can be disabled. a. Remove the shorting jumper (shunt) on the terminal board.

5. Make Powerline Carrier Device Connections - The control panel supports up to 8 Powerline Carrier Devices. If using these devices, they must be connected to the K10145EX transformer, as shown in the SUMMARY OF CONNECTIONS diagram. a. Connect the com/data/sync/ lines from the transformer to terminals 9, 13, and 14, respectively.

If not using the supplied connection cable, you may need to reverse the black and yellow wire connections.

Refer to the

Devices.

- 7 -

LYNXR-IE Installation and Setup Guide

Connecting/Configuring Communication Modules

General

This LYNXR-IE supports central station reporting via long range radio and internet. It also supports upload/download programming capability via the Internet or a Private local area network (Intranet). This allows site maintenance independent of central station monitoring, and modification to sites globally via the

Internet or through a private LAN. Refer to the instructions provided with the LRR/IP Communications

Device being installed for additional information regarding its installation, programming, and registration.

Zone 103 is the supervisory zone for the Communications Device.

Connecting Long Range Radio and Internet Communication Devices

Connect and configure the

LYNXDM-GSM or LYNXDM-IGSM Communications Device as follows (refer to the

Installation Instructions for device that you are installing for additional information):

The wire run between the LYNXR-IE and the Communications Device must not exceed three meters.

LRR/IP Communications Device 24-Hour Standby Power

If you are installing the LYNXDM-GSM or LYNXDM-IGSM Communications Device you must install the Super High

Capacity battery P/N WALYNX-RCHB-SHA in the LYNXR-IE.

Configuring Long Range Radio and Internet Communication Devices

Program the device as required using the 7720P programmer (refer to the Installation Instruction for the device that you are installing for additional information). Note that the device address must be set to 3.

The device must be registered before downloading or alarm reporting can take place.

- 8 -

LYNXR-IE Installation and Setup Guide

AC Power and Backup Battery

The system is powered by a 9VAC, 25VA Plug-in Transformer, K10145EX. Refer to the wiring table below for wire gauge and length.

Use only the provided K10145EX

Transformer.

Distance from Transformer to Control

Up to 23m

Wire Size

0.8mm

23 to 46m

46 to 92m

1.0mm

1.3mm

Wiring to the AC Transformer must not exceed 92 meters using 1.3mm wire. The voltage reading between terminals 15 and 16 of the control must not fall below 9.00VAC.

Do not plug the transformer into the AC outlet until after all wiring connections have been made.

Backup battery

In the event of an AC power loss, the system is supported by a long life backup battery that is supervised for connection and for low voltage conditions. If the battery is missing, or a low battery condition is detected, a

“low battery” message is displayed and a report is sent to the central station. In addition, the system will beep once every 45 seconds to audibly indicate a low battery condition (press any key to stop the beeping).

AC Power and Rechargeable Backup Battery

Connecting AC Power and backup battery

1. Connect wires from the K10145EX AC Transformer to terminals 15 and 16 as shown in the wiring diagram.

RETAINER

NOTE

LYNXRCHKIT-HC

BATTERY PACK SHOWN

2. Remove battery retainer.

3. Peel the backing from tape on the back plate.

4. Insert battery pack into back plate.

5. Install battery retainer.

6. Connect battery connector to receptacle on terminal block PC board.

7. After all wiring connections have been made, snap the front assembly to the back plate and plug the transformer into a 24-hour, 220VAC unswitched outlet.

Note: Rechargeable batteries may take up to 48-hours to fully charge. The “LOW BAT” message should clear within four hours or by entering Test Mode.

BATTERY

PACK

TAPE

WIRING

TERMINALS

BATTERY

RECEPTACLE

Ensure the cover is snapped closed prior to applying ac power.

07000-007-V0

- 9 -

LYNXR-IE Installation and Setup Guide

AC Power and Backup Battery

AC Power and Rechargeable Backup Battery

The LYNXR-IE is equipped with an integral, replaceable, rechargeable battery pack rated at 7.7Vdc. Select the appropriate battery pack, based on the installation’s requirement, and install the battery pack.

Model/Part Number

LYNXRCHKIT-SC

LYNXRCHKIT-HC

LYNXRCHKIT-SHA

Battery StandbyTime

4-hours (minimum)

24-hours (minimum)

24-hours (minimum)

Low Battery Notification

Approximately 1-hour before battery depletion

At least 1-hour before battery depletion

At least 1-hour before battery depletion

Replacing the Rechargeable Battery

1. When battery replacement is required, unplug the transformer from the wall outlet, and open the control panel cover.

2. Remove the battery retainer and disconnect the battery pack connector from the receptacle on the terminal block PC board.

RETAINER

BATTERY

PACK

LYNXRCHKIT-HC OR LYNXRCHKIT-SC

3. Remove the battery pack from the back plate.

4. If required, replace the tape that secures the battery pack.

5. Install a replacement battery pack (P/N

LYNXRCHKIT-SC, LYNXRCHKIT-HC or

LYNXRCHKIT-SHA) into the back plate.

6. Install the battery retainer.

7. Connect the battery connector to the receptacle on the terminal block PC board.

8. After the wiring connection has been made, snap the front assembly to the back plate.

9. Plug the transformer into a 24-hour, 220VAC unswitched outlet.

BATTERY

CONNECTOR

BATTERY

RECEPTACLE

LYNXRCHKIT-SHA

TAPE

RETAINER

10. Rechargeable batteries may take up to 48hours to fully charge. The “LOW BAT” message should clear within four hours or by entering Test Mode.

BATTERY

PACK

BATTERY

CONNECTOR

TAPE

BATTERY

RECEPTACLE

Ensure the control panel assembly is snapped closed prior to applying AC power.

- 10 -

07000-006-V1

LYNXR-IE Installation and Setup Guide

Installing Wireless Zones

General Information

Zones: The control supports up to 24 wireless zones using Secom uni-directional GY Series transmitters, and up to 16 wireless buttons.

Range: The built-in RF receiver can detect signals from wireless transmitters within a nominal range of

200 feet.

Transmitters: Secom uni-directional GY Series transmitters have built-in serial numbers that must be entered into the system using the

✻56 or ✻83 interactive mode, or input to the control via the downloader.

Each transmitter's zone number is programmed into the system in

✻56mode. Some transmitters can support more than one "zone" (referred to as loops or inputs). Each loop must be assigned a different zone number.

For button transmitters (RF "keys") such as the CSK800GY, you must assign a unique zone number to each individual button used on the transmitter. Each button on the transmitter also has a pre-designated loop or input number, which is automatically displayed.

Transmitter Supervision

Except for some transmitters/keypads that may be carried off-premises each transmitter is supervised by a check-in signal that is sent to the receiver at 70–90 minute intervals. If at least one check-in is not received from each supervised transmitter as specified in the device’s Installation Instructions, the

"missing" transmitter number(s) and "FAULT" will be displayed. The supervision for a particular transmitter in the system that may also be carried off the premises may be turned off by entering it as a

"UR" (unsupervised RF) type, as described in the

56 Enhanced Zone Programming Mode section.

Secom Series transmitters have built-in tamper protection and will annunciate as a fault condition if covers are removed.

Transmitter Input Types

Each of the following transmitters has one or more unique factory-assigned input (loop) ID codes. Each of the inputs requires a programming zone

(e.g., a

TC805HF

's four inputs require four button zones)

.

Transmitters can be entered as one of the following types

(see transmitter’s instructions for appropriate input type)

:

Type Description

"RF" (Supervised RF)

Sends periodic check-in signals, as well as fault, restore, and low battery signals.

The transmitter must remain within the receiver's range.

"UR" (Unsupervised RF)

Sends all the signals that the "RF" type does, but the control does not supervise the check-in signals. The transmitter may therefore be carried off-premises.

"BR" (Unsupervised Button RF)

These only send fault signals. They do not send low battery signals until they are activated. The transmitter may be carried off-premises.

Transmitter Battery Life

• Batteries in the wireless transmitters may last from 4–7 years, depending on the environment, usage, and the specific wireless device being used. Factors such as humidity, high or low temperatures, as well as large swings in temperature may all reduce the actual battery life in a given installation. The wireless system can identify a true low battery situation, thus allowing the dealer or user of the system time to arrange a change of battery and maintain protection for that point within the system.

• Button-type transmitters should be periodically tested for battery life. The CSK800GY and TCB800M button transmitters have replaceable batteries.

When replacing wireless transmitter batteries, refer to the Installation Instructions provided with the

specific wireless device.

Using the Transmitter Sniffer Mode

Use this mode after all transmitters have been entered to check that all transmitters have been properly programmed.

1. Enter

Note: If the communicator is in the process of sending a report to the central station, the system will not go into the Sniffer mode. If so, wait a few minutes and try again.

- 11 -

LYNXR-IE Installation and Setup Guide

Installing Wireless Zones

2. The keypad will display all zone numbers, which have a non-zero Zone Type (even if serial numbers were not learned yet). Fault each transmitter in turn, causing each one to send a signal. As the system receives a signal from each of the transmitters, the zone number of that transmitter will disappear from the display. The transmitters may be checked upon installation, or in an installed system.

3. When all transmitters have been checked, exit Sniffer mode. Enter Installer Code (4112) + OFF.

Notes: (1) Sniffer mode does not automatically expire. You must manually exit (Installer Code + OFF) Sniffer mode to return to normal operation.

(2) All BR-type units must physically be activated to clear the display, since they do not automatically send check-in signals.

(3) When one button of a transmitter (RF, UR, or BR) is activated, all zones assigned to other buttons on that transmitter are cleared.

(4) Any transmitter that is not “entered” will not turn off its zone number.

(5) When installing the DOD800GY, the distance between the transmitter and the hard-wire contact must not exceed 5 feet. No more than 10 contacts per zone should be connected to the same RF sensor loop.

Go/No Go Test Mode

The Go/No Go tests will verify adequate RF signal strength from the proposed transmitter location, and allow you to reorient or relocate transmitters if necessary, before mounting the transmitters permanently.

This mode is similar to the transmitter Test mode, except that the wireless receiver gain is reduced. This will enable you to make sure that the RF signal from each transmitter is received with sufficient signal amplitude when the system is in the normal operating mode.

2. Once you have placed transmitters in their desired locations and the approximate length of wire to be run to sensors is connected to the transmitter's screw terminals (if used), fault each transmitter.

Conducting this test with your hand wrapped around the transmitter will cause inaccurate results.

On button type transmitters (i.e.; CSK800HF and TC805HF) that have been programmed to set ARM

AWAY, ARM STAY, or DISARM, pressing a button will take the system out of the Go/No Go Test mode and cause the programmed action to occur.

a. The keypad will beep three times indicating signal reception and will display the appropriate zone number. b. If the keypad does not beep, reorient or move the transmitter to another location. Usually a few inches in either direction is all that is required.

3 If each transmitter produces the proper keypad response when it is faulted, you can then permanently mount each of the transmitters according to the instructions provided with them.

4 Exit the Go/No Go Test mode by entering: Installer Code (4112) + OFF.

Secom GY/HF Series Transmitters

(Refer to this information when programming transmitters)

The following illustration shows the compatible transmitters and their associated input types and loop designations.

LOOP 1

LOOP 1

1

4

2

5

7

8

3

6

9

0

SOS

LOOP 1

SOS

SOS

CSK800HF

ENROLL AS

"BR"

DOD800GY

ENROLL AS

"RF"

IRPI800M

ENROLL AS

"RF"

DTO800HF

ENROLL AS

"RF"

IRX800GY

ENROLL AS

"RF"

TC805HF

ENROLL AS

"BR"

IR800PIGY

ENROLL AS

"RF"

- 12 -

LYNXR-IE Installation and Setup Guide

Mechanics of Programming

General Programming Information

Programming options are stored in non-removable, electrically erasable, nonvolatile EEROM memory. The system can be programmed at any time, even at the installer's premises prior to the actual installation.

Simply apply power temporarily to the Control and then program the unit as desired. There are four programming modes:

Data field programming (used for setting various system options).

Interactive menu mode programming (used for programming zone information, programming

Powerline Carrier Devices, and for entering transmitter serial numbers).

Voice Prompt programming (used for setting various system options).

Pass-Thru programming (used for programming connected LRR/IP Communications Device).

The system can also be programmed remotely, using an IBM Personal Computer, a modem, and Compass

Downloader for Windows. See the Remote Programming/Control (Downloading) section.

Note: You may find it convenient to adjust the volume setting before entering the Program Mode. This will allow you to clearly hear the feedback announcements or system beeps in the Programming Mode, of the system’s built-in speaker. To adjust the volume, press FUNCTION + VOLUME+ [3] or [6]. Upon exiting the Program Mode, the system will reset the volume to the default value (mid level).

Entering Program Mode

Use one of the following methods to enter Programming Mode:

1. Press both the [

✻] and [#] keys at the same time, within 50 seconds after power is applied to the

Control or from exiting Programming mode, OR

2. After power-up, enter the Installer Code (4112) + 800 to enter Expert Programming mode (This method disabled if Program mode is exited using

✻98). OR enter Installer Code (4112) + 888 to enter Voice Prompt Programming mode.

1. If a different Installer Code has been programmed, use that code to enter the Programming mode.

2. Once the Installer Code has been entered, you have 35 seconds to open the LYNX case before generating a tamper condition.

3. Upon entering programming mode, the LCD display will become active and will remain active while the system is in this mode.

4. Once you have entered the Program mode, data field “20” (the first data field in the system) will be displayed and both keypad LEDs will flash. If you have entered the Voice Prompt Programming mode. “Pro” will be displayed.

Programming a Data Field

1. Press

✻] + Field No. (for example, ✻21), followed by the required entry.

2. When you have completely programmed a data field, the keypad will “beep” three times and then automatically display the next data field in sequence. To go to a different field, press [

✻] plus the desired field number.

3. If the number of digits that will be entered in a data field is less than the maximum number of digits available (e.g. phone number field), enter the desired data, then press [

✻] to advance to the next data field.

4. If a nonexistent field has been entered, the keypad will display “EE”. Simply re-enter [

✻] plus a valid field number.

To view a data field without making changes:

Enter [#] + Field No.

Data will be displayed for that field.

To delete an entry in a field:

Enter [✻] + Field No. + [✻].

(Applies only to fields

✻40–✻44, ✻88 and ✻94).

- 13 -

LYNXR-IE Installation and Setup Guide

Mechanics of Programming

Interactive Menu Mode Programming

(56, 80, 81, 83, 84, 85)

Press

[✻] + interactive mode No.

(i.e.,

✻56). The keypad will display the first of a series of prompts. A detailed procedure (with displays of prompts) is provided in later sections of this manual.

Interactive Mode

✻56 Enhanced Zone Programming Mode

✻80 Device Programming Menu Mode

✻81 Zone List Menu Mode

✻83 Enhanced Sequential Mode

✻84 Assign Zone Voice Descriptors

✻85 Record Custom Voice Descriptors

Used to Program

Zone characteristics, report codes, and serial numbers

Powerline Carrier Devices

Zone Lists for powerline carrier activation

Secom Series transmitter serial numbers

Voice descriptors for each zone

Up to 5 custom voice descriptors for zones

Loading Factory Defaults

To load the factory defaults, enter the Programming mode, press

✻97, then press number 1, 2, 3, or 4 to select from default tables

1-4 at the back of this manual, or press “0” if you are not selecting a default table.

If a default table is loaded, any data that has already been programmed into the system will be changed according to the

default table selected!

96 resets all subscriber account numbers and CSID in preparation for an initial download.

Exiting Program Mode

98 inhibits re-entry into the Expert or Voice Prompt Programming modes using the Installer Code.

99 allows re-entry into the Expert Program mode using Installer Code (4112) + 800 or into the Voice

Prompt Programming mode using Installer Code (4112) + 888.

Note: After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset delay, press [#] + [0].

Pass-Thru Programming

This mode allows the Installer to use the LYNXR-IE keypad and display to program the communications device that is connected to the LYNXR-I. Refer to the communications device’s installation instruction to determine whether this feature is supported.

Entering Pass-Thru Programming mode

1. After power-up, enter the Installer Code (4112) + 899.

2. Once you have entered Pass-Thru Programming mode “PtP” will be displayed on the keypad.

3. Refer to the Installation Instructions for the LRR/IP Communications Device being installed for additional programming information.

LYNXR-IE will abort this mode:

• When it receives an abort command from the new communications device.

• If it fails to communicate with an communications device after 20 attempts.

• 30 minutes after the last key has been pressed.

- 14 -

Type 00

Zone Not Used

LYNXR-IE Installation and Setup Guide

Zone Response Type Definitions

General Information

During programming, you must assign a zone type to each zone, which defines the way in which the system responds to faults in that zone. Zone types are defined below.

Zone type 00 is used to program a zone that is not used.

Type 01

Entry/Exit Burglary #1

Type 02

Entry/Exit Burglary #2

Type 03

Perimeter

Burglary

Type 04

Interior, Follower

Type 05

Trouble by Day/

Alarm by Night

Type 06

24-hour

Silent Alarm

Zone type 01 is usually assigned to sensors or contacts on primary entry and exit doors.

Zone Characteristics:

• Entry delay #1 is programmable from 0-99 seconds (field

35).

• Exit delay is independently programmable from 0-99 seconds (field

34).

• Exit and entry delays when armed in AWAY or STAY mode.

• No entry delay when armed in STAY NO DELAY or AWAY NO DELAY mode.

• Exit delay regardless of the arming mode selected.

Zone type 02 is usually assigned to sensors or contacts on which secondary entry and exit doors that might be further from the keypad (typically used for a garage, loading dock, or basement door).

Zone Characteristics:

• Entry delay #2 is programmable from 0-99 seconds (field

36).

• Exit delay is independently programmable from 0-99 seconds (field

34).

• Secondary entry delay, if armed in the AWAY or STAY mode.

• No entry delay when armed in the STAY NO DELAY or AWAY NO DELAY mode.

• Exit delay begins regardless of the arming mode selected.

Zone type 03 is usually assigned to all sensors or contacts on exterior doors and windows.

Zone Characteristics:

Instant alarm, when armed in AWAY, STAY, STAY NO DELAY, or AWAY NO

DELAY mode.

Zone type 04 is usually assigned to a zone covering an entry area (i.e.: foyer, lobby, or hallway) that one must pass upon entry (after faulting the entry/exit zone) to reach the keypad. It provides an instant alarm if the entry/exit zone is not violated first, and protects an area in the event an intruder has hidden on the premises before the system is armed, or gains access to the premises through an unprotected area.

Zone Characteristics:

• Delayed alarm (using the programmed entry/exit time) if entry/exit (types 01 or

02) or interior-with-delay (type 10) zone is faulted first.

• Instant alarm in all other situations.

• active when armed in AWAY or AWAY NO DELAY mode.

• Bypassed automatically when armed in STAY or STAY NO DELAY mode.

Zone type 05 is usually assigned to a zone that contains foil-protected doors or windows or covers a sensitive area (i.e.: stock room, drug supply room, etc.) It can also be used on a sensor or contact in an area where immediate notification of an entry is desired.

Zone Characteristics:

• Instant alarm, when armed in AWAY, STAY, STAY NO DELAY, or AWAY NO

DELAY (night) mode.

• Provides a latched trouble sounding from the keypad and, if desired, a central station report during the disarmed state (day).

Zone type 06 is usually assigned to a zone containing an Emergency button (silent emergency).

Zone Characteristics:

Sends a report to the central station but provides no keypad display or sounding.

- 15 -

LYNXR-IE Installation and Setup Guide

Zone Response Type Definitions

Type 07

24-hour

Audible Alarm

Zone type 07 is usually assigned to a zone containing an Emergency button

(audible emergency).

Zone Characteristics:

Sends a report to the central station, and provides alarm sounds externally and at the keypad.

Type 08

24-hour

Auxiliary Alarm

Type 09

Supervised Fire

Type 10

Interior with Delay

Type 20

Arm–Stay

Type 21

Arm–Away

Type 22

Disarm

Type 23

No Alarm Response

Zone type 08 is usually assigned to a zone containing a button for use in personal emergencies or to a zone containing monitoring devices (i.e.: water or temperature sensors, etc.).

Zone Characteristics:

Sends a report to the central station and provides an alarm sound at the keypad. (No bell output is provided and there is no keypad timeout.)

Zone type 09 can be assigned to any wireless zone used as a fire zone. This zone type is always active and cannot be bypassed.

Zone Characteristics:

• Bell output will pulse when this zone type is alarmed.

Zone type 10 is bypassed when the panel is armed in the STAY or STAY NO

DELAY mode.

Zone Characteristics:

Entry delay #1 (with programmed entry time) when armed in the AWAY mode.

Entry delay begins whenever sensors in this zone are violated, regardless of whether an entry/exit delay zone was tripped first.

No entry delay when armed in the AWAY NO DELAY mode.

Exit delay regardless of the arming mode selected.

Zone type 20 is a special-purpose zone type used with wireless pushbutton units.

Zone Characteristics:

Exit delay regardless of the arming mode selected.

System is armed in the STAY mode when the zone is activated.

Zone number is sent to the central station as a user number when arming or disarming.

Zone type 21 is a special-purpose zone type used with wireless pushbutton units.

Zone Characteristics:

System is armed in the AWAY mode when the zone is activated.

Zone number is sent to the central station as a user number when arming or disarming.

Zone type 22 is a special-purpose zone type used with wireless pushbutton units.

Zone Characteristics:

Disarms the system when the zone is activated.

Zone type 23 can be used on a zone when a Powerline Carrier Device (e.g.,

X10) action is desired, but with no accompanying alarm (e.g., front door light).

Type 24

Silent Burglary

Zone type 24 is usually assigned sensors or contacts on exterior doors and windows where bells and/or sirens are NOT desired.

Zone Characteristics:

Instant alarm, with NO audible indication when is armed in the AWAY,

STAY, STAY NO DELAY, or AWAY NO DELAY mode.

Report sent to the central station.

Note: Keypad beeps if the zone is faulted when system is disarmed and Chime mode is on.

- 16 -

LYNXR-IE Installation and Setup Guide

Data Field Descriptions

Defaults (where applicable) are Indicated in bold text.

The following pages list all data fields in this Control (in numerical order). Use the blank programming form to record the data for this installation. Note that both keypad LEDs flash while in Programming mode.

Note: Entering a number other than one that is specified will give unpredictable results.

20

22

23

25

26

27

28

29

30

31

32

33

34

Installer Code

Enter 4 digits, 0-9

Keypad Backlight Timeout

0 = no timeout; always backlight keys

1 = turn backlighting off after inactivity

Forced Bypass

0 = no forced bypass

1 = provide automatic bypass of all open (faulted) zones

Powerline Carrier Device (X10) House ID

0 = A 4 = E 8 = I # + 12 = M

1 = B 5 = F 9 = J # + 13 = N

2 = C 6 = G # + 10 = K # + 14 = O

3 = D 7 = H # + 11 = L # + 15 = P

Chime by Zone

0 = no (chimes on fault of any entry/exit or perimeter zone when Chime mode is activated

1 = yes (chimes on fault of those zones assigned to

Zone List 3 when Chime mode on)

Real Time Clock Display

0 = do not display the time

1 = display the time

Power Line Frequency/Real Time Clock

Time Base

0 = 60 Hz, Real Time Clock runs from power line

1 = 50 Hz, Real Time Clock runs from power line

2 = 60 Hz, Real Time Clock runs from crystal

3 = 50 Hz, Real Time Clock runs from crystal

Daylight Savings Time Start/End Month

0, 0 = no daylight saving time used

1-12 = start month and end month

Daylight Savings Time Start/End Week

0 = disable 4 = fourth weekend

1 = first weekend of month 5 = last weekend

2 = second weekend 6 = next to last

3 = third weekend 7 = 3 rd from last

Single Alarm Sounding Per Zone

(per armed period)

0 = no limit on alarm sounding per zone

1 = limit alarm sounding to once per arming period for a given zone

Fire Sounder Timeout

0 = yes, fire sounder timeout after time programmed in field

33

1 = no fire sounder timeout; continue sounding until manually turned off

Alarm Bell Timeout

0 = No timeout

1 = 4 min

2 = 8 min

3 = 12 min

Exit Delay

00-99 = exit delay time in seconds

4 = 16 min

The Installer Code is used to enter the 4-digit Master Security

Code. See "Master Code" in the System Operation section for procedure.

Note: LYNX does not allow duplication of Installer code. If a duplicate code is entered the entry is rejected and LYNX issues single long beep indicating rejection. The old installer code remains unchanged.

This option allows the choice of either always backlighting the keypad or turning the backlighting off after 10 seconds of keypad inactivity.

All zones bypassed by this function will be displayed after the bypass is initiated.

Powerline Carrier Devices require a House ID. This field identifies this House ID to the Control. The Powerline Carrier

Devices are programmed in field

✻80.

This option allows the installer to define the specific zones intended to chime when faulted while the system is in Chime mode. If enabled, these zones are defined in zone list 3 (see

81

Zone List Menu Mode).

Refer to the User’s Manual for setting the clock time and date.

Select Power Line Frequency/Real Time Clock synchronization

Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12.

Enter the appropriate start and end weekend of the month.

This field applies only to burglary zones (zone response types 1-

5, 10), and affects long range radio reporting but does not affect central station reporting.

Note: This field applies only to the bell and does not affect keypad sounds.

This Control complies with NFPA requirements for temporal pulse sounding of fire notification appliances.

Temporal pulse sounding for a fire alarm consists of the following: 3 pulses – pause – 3 pulses – pause – 3 pulses. . .

This field determines whether the external sounder will shut off after time allowed, or continue until manually turned off.

The system will wait the time entered before sounding an alarm if the exit door is left open after the system has been armed.

- 17 -

LYNXR-IE Installation and Setup Guide

Data Field Descriptions

35

36

Entry Delay 01

00-99 = entry delay time in seconds.

Entry Delay 02

00-99 = entry delay time in seconds.

The system will wait the time entered before sounding alarm upon entering if system is not disarmed.

Note: Entry delay should be less than 45 seconds in order to comply with EN50131.

The system will wait the time entered before sounding alarm upon entering.

Note: Entry delay should be less than 45 seconds in order to comply with EN50131.

37

38

Audible Exit Warning/Quick Exit

Exit Warning Quick Exit

0 = no exit warning sound

1 = provide exit warning sound when armed AWAY

0 = no quick exit

1 = allow quick exit

Confirmation of Arming Ding

0 = no ding

1 = confirmation ding after arming system

2 = confirmation ding after arming from RF button or RF keypad only

Exit Warning: Sound consists of slow continuous beeps until last

5 seconds, when it changes to fast beeps. The warning sound will end at the termination of exit delay.

Quick Exit: If enabled, user can restart the exit delay time after arming in STAY mode by entering the user code and pressing the STAY key. This avoids having the user disarm then re-arm the system after allowing someone to enter or exit

Confirmation of arming is provided by a 1/2 second external sounder “ding” that sounds when closing report is sent, or at the end of exit delay

.

If Option 2 is selected the external sounder “ding” occurs immediately after the system receives the RF transmission.

39

Power Up In Previous State

0 = always power up in a disarmed state

1 = assume the system status prior to power-down

When the system powers up armed, an alarm will occur 1 minute after arming if a zone is faulted, and any bypassed zones will be unbypassed.

Note: If the previous state was armed AWAY or STAY, the system will not respond to sensor changes for 1 minute, which allows time for sensors such as PIRs to stabilize.

DIALER PROGRAMMING (

40–

50)

Fields

40,

41,

42: Enter up to the number of digits shown. Enter 0–9, # + 11 for ‘*’; # + 12 for ‘#’; # + 13 for a pause

(2 seconds), # + 14 for “+”. Whenever AAV is used, primary (field

✻41) and secondary (field ✻42) phone numbers should be preceded with the call waiting disable command. Otherwise, there is the possibility of connection of the third party to

LYNXR-IE during AAV mode.

40

41

42

PABX access Code

Enter up to 6 digits if PABX is needed to access an outside line.

Primary Phone No.

Enter up to 20 digits.

Note: SMS phone numbers must have a maximum of

15 digits.

Secondary Phone No.

Enter up to 24 digits.

Note: SMS phone numbers must have a maximum of

15 digits.

If fewer than 6 digits need to be entered, exit by pressing [

✻]. To clear entries from field, press

✻40✻.

If fewer than 20 digits entered, exit by pressing [

✻]. To clear entries from field, press

✻41✻.

Note: Backup reporting (8 attempts are made to the secondary phone number if no kissoff is received after 8 attempts to the primary number) is automatic only if there is a secondary phone number (field ✻42).

If fewer than 24 digits entered, exit by pressing [

✻]. To clear entries from field, press

✻42✻. See backup reporting note for field

✻41.

All four digits of the Subscriber account number must be entered in Fields 43 and 44.

Fields

43 and

44:

Enter 0 as the first digit of a 4-digit account number for Nos. 0000–0999. Enter [

] as the fifth digit if a 4-digit account number is used. Exit field by pressing [

] if only 3 digits are used. To clear entries from field, press

43

or

44

. See blank Programming Form for examples of account number entries. Enter digits 0–9; # +11=B; # +12=C; # +13=D; #

+14=E; or # +15=F.

43

44

Primary Subs account No.

Enter a four or ten digit account number.

Secondary Subs account No.

Enter a four or ten digit account number.

Enter the primary subscriber account number.

To clear entries from field, press

✻43✻.

Enter the secondary subscriber account number.

To clear entries from field, press

✻44✻.

- 18 -

LYNXR-IE Installation and Setup Guide

Data Field Descriptions

Field

46: Enter up to 24 digits. Do not fill unused spaces. Enter 0-9, #+11 for ‘*’; #+12 for ‘#’; #+13 for a pause (2 seconds), #+14 for special character

46

“Follow Me Reminder” Phone Number

Enter up to 24 digits.

This option allows the user to schedule a time driven message.

When activated the system will dial the phone number programmed and deliver a voice message (custom words 72, 73 and 74) over the vocal channel. This option always enabled. If

PSTN and GSM vocal channels are available LYNXR-IE will use the PSTN line.

If using the Follow Me Reminder feature, enter the phone number here. If fewer than 24 digits are entered, exit by pressing [

✻]. To clear entries from the field press

✻46✻.

The telephone message can be terminated (acknowledged) by pressing any key on the telephone keypad. Pressing any key on the local LYNXR-IE keypad will terminate (acknowledge) both the follow me and the local reminder announcements.

Note: The follow me reminder announcement will be terminated if any other event requires the system to dial out or if an audible alarm has occurred.

47

Phone System Select

Central Dialing Mode

This option is used to enter the correct type of phone dialing

(pulse or tone), and to select the correct WATS line option for the

Central Station. This option is used to activate the Speaker Phone

No WATS

0 = No

Speaker

Phone

1 = No

Speaker

Phone

4 = With

Speaker

Phone

5 = With

Speaker

Phone option.

Note: If using pulse dialing, you must enter the numbers slowly in order to allow the pulse dialer time to operate.

WATS

2 = No

Speaker

Phone

3 = No

Speaker

Phone

6 = With

Speaker

Phone

7 = With

Speaker

Phone

Field

48: The following Event/Restore Messages will be sent to the Primary (Owner 1) and Secondary (Owner 2) Phone

Numbers if GSM SMS (Option 4) is selected in this field. The associated Contact ID

®

Codes are also listed here.

Event SMS text

Fire

Restore SMS text

- - -

Duress

Silent Emergency

Audible Emergency

Alarm

Alarm

Alarm Entry/Exit

Alarm

Panel Tamper Alarm

8042 Panel Tamper Alarm

Alarm

Emergency

AC Power Fault

Panel Low Batt

Panel Tamper Trouble

RF Jam

Phone Fail

Communication failure

- - -

- - -

- - -

- - -

- - -

Alarm Entry/Exit End

- - -

Panel Tamper Alarm End

- - -

- - -

- - -

AC Power Fault End

Panel Low Batt End

Panel Tamper Trouble End

RF Jam End

Phone Fail End

Communication failure end

Fire Loop Trouble

Exit Alarm

Global Trouble

RF supervision trouble

RF sensor tamper

RF Sensor: Low Batt

Armed AWAY

Scheduled Arm

Alarm canceled

Fire Loop Trouble End

- - -

Global Trouble End

RF supervision End

RF sensor tamper End

RF Sensor: Low Batt End

Disarmed

- - -

- - -

373

374

380

381

383

384

401

403

406

Remote Armed

Armed Away

Armed STAY

Remote Disarmed

- - -

Disarmed

407

408

441

Bypass Bypass

Not Applicable - - - 602

Not Applicable

Not Applicable

Not Applicable

Syst Inactivity

System not yet disarmed

8042 SMS System Manual Message

SMS System Manual Message

- - -

- - -

- - -

Syst Inactivity End

- - -

- - -

- - -

606

607

623

654

- - -

- - -

- - -

150

301

302

341

344

351

353

121

122

123

131

132

134

135

145

145

146

CID

Code Definition

110 Fire Alarm

Duress

Alarm, 24-hour silent

Alarm, 24-hour audible

Alarm, Perimeter

Alarm, Interior

Alarm, Entry/Exit

Alarm, Day/Night

Cover Tamper Fail

Expander Module Tamper Alarm

Silent Burglary

Alarm, 24-hour Auxiliary

AC Power

Low system battery

Cover Tamper Fail When Disarmed

RF Jam Detected

Phone Line Failure

ECP communication failure

Fire Loop Trouble

Exit Error Alarm

Global Trouble, Trouble Day/Night

RF Supervision Trouble

RF Sensor Tamper (Trouble)

RF Sensor Low Battery

Disarmed, Armed AWAY (NO DELAY), Armed AWAY

Scheduled Auto Arm

Cancel by user

Remote Arm/Disarm (Downloading)

Quick Army Away/No Delay

Disarmed/Armed STAY/NO DELAY

Periodic Test

AAV to follow

System Test

Event Log 80% Full

System Inactivity

System has not been disarmed

SMS System Manual Message

SMS System Manual Message

- 19 -

LYNXR-IE Installation and Setup Guide

Data Field Descriptions

48

Report Format for Primary/Secondary

Primary Secondary

See choices below See choices below

0 = PSTN Digital (ADEMCO Contact ID®)

1 = PSTN Vocal

2 = GSM Digital (ADEMCO Contact ID®)

3 = GSM Vocal

4 = SMS (Short message Service)

Note: Option 0 or 1 (PSTN) must be used for Site initiated uploading/downloading, Remote Phone Control and Speaker Phone options.

The field is a two-digit entry field. It separately defines the

Primary and Secondary report channels. The dialing options included with the LYNXR-IE allow you to send reports to either a

Central Station or to a private phone either as the Primary or

Secondary phone number. When dual reporting is selected and

AAV is enabled, report will go to the primary destination and then the AAV session will be established on the secondary destination. If the second destination is not a Central Station the

AAV will not be established. If options 1, 3 or 4 is entered as the first or second entry (or as both), the User will receive messages as defined in Field *49.

Example: to select PSTN Vocal as the Primary and GSM SMS as the Secondary enter “14”.

Notes: (1) The maximum number of alarm and alarm restore reports during one armed period is determined by field

✻92.

(2) Option 0 (PSTN Digital), 2 (GSM Digital)must be selected for AAV.

(3) The control validates the data entered in this field. If the selection is not valid the control will emit a single long beep indicating that the selection has been rejected.

The control replaces the selection with the default value, which is displayed on the keypad, and advances to the next field.

0 = PSTN Digital: DTMF Contact ID reporting to central station only, including two way audio alarm verification voice session (if option is enabled).

1= PSTN Vocal: Follow me voice system announcements to

Primary and Secondary (Owner 1 and 2) phone numbers only

(system current status announcements to the owner phone).

Silent alarm announcement will be “SILENT POLICE”.

Note: This format does not provide a two-way voice capability for the owner.

2 = GSM Digital: Contact ID reporting over the audio channel of the GSM. To central station only, including two way audio verification voice session (if option is enabled).

Note: This option is the same as PSTN Digital but uses GSM digital for communication.

3 = GSM Vocal: Follow me voice system announcements to

Primary and Secondary (Owner 1and 2) phone numbers.

System sends current status announcements to the owner phone, except silent alarm announcement that is not sent over the owner phone. Silent alarm announcement will be “SILENT

POLICE”.

Note: This option is the same as PSTN Vocal but uses the GSM for communication and does not provide two way voice capabilities for the owner.

4 = SMS: Short Message Service messages are sent to Owner 1 and 2 phone numbers only. There is no two way voice capability.

Note: The SMS message is not acknowledged. In addition the receiving mobile phone must be active on the network in order to receive the message.

SMS messages format: XXXX “SMS text” NN where:

XXXX = Primary or Secondary subscriber account number

NN = Zone or the User number

- 20 -

LYNXR-IE Installation and Setup Guide

Data Field Descriptions

49

50

51

52

54

58

Split/Dual Reporting

To Primary

0 = All reports

1 = Alarms, Restore, Cancel

2 = All except Open/Close, Test

3 = Alarms, Restore, Cancel

4 = All except Open/Close, Test

5 = All reports

To Secondary

None, unless primary

fails, then all

Others

Open/Close, Test

All

All

All

15-Second Dialer Delay (Burglary)

0 = no dialer delay

1 = provide 15-second delay of burglary alarm report when armed away

Periodic Test Report

0 = no test report 2 = weekly

1 = once every 24 hrs 3 = once every 30 days

First test Report Offset

0 = 24 hrs after exit program mode or download

1 = 6 hours after exit program mode or download

2 = 12 hrs after exit program mode or download

3 = 18 hrs after exit program mode or download

Lack of Usage Notification

0 = Disabled

1 = 1 day

4 = 90 days

5 = 180 days

2 = 7 days

3 = 27 days

6 = 365 days

Note: There is no local annunciation indicating that this report has been sent to the Central Station.

RF Jam Detection

0 = no jam detection

1 = RF jam detection with event logging, but no central station report

2 = RF jam detection with event logging and with central station report (if trouble/restore report is enabled in fields ✻60, ✻71)

This field is used to select a reporting option.

When IP Digital Report Format (Option 5) is selected in Field *48, the selections in *49 are limited to 0-2.

Note: This eliminates the possibility of duplicate reports being sent to the same Central Station.

When dual reporting is selected and AAV is enabled, report will go to the primary destination and then the AAV session will be established on the secondary destination. If the secondary destination is not a Central Station, the AAV will not be established.

Note: The control validates the data entered in this field. If the selection is not valid the control will emit a single long beep indicating that the selection has been rejected. The control replaces the selection with the default value, which is displayed on the keypad, and advances to the next field.

If enabled, provides delay of burglary report to the central station, and allows time for the subscriber to avoid a false alarm transmission. The delay applies only to zone type 3 and 5 alarms and not to zone type 24 alarms (silent burglary) or to 24-hour zone types 6, 7, and 8 (silent panic, audible alarm, auxiliary alarm), which are always sent as soon as they occur.

Test report code entered in field

✻64 is sent.

Select the time for the first report following programming or downloading.

If enabled, notifies the central station if an end user is not operating their security system by sending a System Inactivity report 654. The report will be sent only to the Primary phone number and only if Contact ID® format was selected.

Note: The report will follow the ✻49 = 0 rules, no matter which selection was made in ✻49.

For Event Logging, Option 2 must be selected.

If the control detects an RF Jam condition, a “FAULT” message appears for zone 90. The Contact ID® code for RF Jam is 344.

SYSTEM STATUS AND RESTORE REPORT CODES PROGRAMMING (

59 – 76, & 89)

Program Report Codes using the interactive

✻56 Enhanced Zone Programming Mode, or codes can be entered in data fields

✻59-✻76, ✻89. The following is a set of guidelines when programming report codes. The actual report code digits that you enter depend upon the particular installation, and should be in agreement with you and the central station office receiving the signals.

Enter a digit in the first box to enable the zone to report. Use a different digit for each zone until you have used up available digits. If the number of zones exceeds the number of available digits, begin with digit 1 again. This is an

"enabling" code only and is not the actual code sent to the central station office. Entries in the second boxes will be ignored. For system status (non-alarm) codes, enter a “1” in the first box for all the system conditions you want to send to the central station. A "0" in the first box disables the report.

- 21 -

LYNXR-IE Installation and Setup Guide

Data Field Descriptions

59

60

61

62

63

64

Exit Error Report Code

(See programming notes)

If the system is armed and an entry/exit or interior zone is still open after the exit delay time has expired, an alarm will sound at the keypad and external sounder. If the system is disarmed before the end of the entry delay that immediately follows, the alarm sounding will stop and no message will be sent to the central station. The keypad will display “CA (CANCELED

ALARM).”

If the system is not disarmed before the end of the entry delay mentioned above, and an entry/exit or interior zone is still open, an “exit alarm” message will be sent to the central station if an

Exit Error report code is selected in this field. The keypad will display “EA (EXIT ALARM),” and the alarm sounding will continue until the system is disarmed (or timeout occurs).

An Exit Alarm condition will also result if a fault occurs in an exit or interior zone within 2 minutes following the end of the exit delay, and an “Exit Alarm” message will be sent to the central station.

The message will contain the zone number and error code 374

(Trouble–Exit Error). This message will go to the primary phone no. Under any of these conditions, no restore message will be sent.

If “0” is entered in this field, no special message will be sent, only the regular alarm and alarm restore code for the zone.

This will be sent if a zone goes into trouble.

65

66

67

68

RF transmitter Low Batt. Report Code

(

See programming notes

)

Cancel Report Code

(

See programming notes

)

RESTORE REPORT CODES (

70–

76)

70

71

72

73

Alarm Restore Report Code, 1st Digit

(

See programming notes

)

Trouble Restore Report Code

(

See programming notes

)

Bypass Restore Report Code

(

See programming notes

)

AC Restore Report Code

(

See programming notes

)

74

Low Battery Restore Report Code

(See programming notes)

75

RF Transmitter Low Batt. Restore Code

(See programming notes)

75

Trouble Report Code

(

See programming notes

)

Bypass Report Code

(

See programming notes

)

AC Loss Report Code

(

See programming notes

)

Low Battery Report Code

(See notes above)

Test Report Code

(

See programming notes

)

Open Report Code

(

See programming notes

)

Arm AWAY/STAY Report Code

(

See programming notes

)

This will be sent when a zone is manually bypassed.

Timing of this report is random with up to a 4-hour delay. If AC restores before the report goes out, there is no AC restore report.

This will be sent when a low battery condition exists in the system’s standby battery.

This is sent periodically to test that the communicator and phone lines are operational (frequency of report is selected in field

✻51).

This is sent upon disarming of the system.

This option allows for independent programming of AWAY and

STAY reports.

Note: OPEN reports are not sent if the associated closing report is not enabled.

This is sent in the event that a wireless transmitter low battery condition exists.

This is sent upon disarming of the system after an alarm condition was reported.

Sent when the zone that caused an alarm is restored to its nonfaulted condition.

Sent when a trouble in a zone is restored.

Sent when a zone that has been bypassed is unbypassed.

Sent when AC power has been restored after an AC power outage.

Sent when a system low battery condition is restored to normal.

RF Transmitter Low Batt. Restore Code

(

See programming notes

)

Sent when a transmitter that previously sent in a “low battery” message has sent a message indicating it no longer has a low battery condition.

Sent when a transmitter that previously sent in a “low battery” message has sent a message indicating it no longer has a low battery condition.

- 22 -

76

78

82

87

89

90

91

Test Restore Report Code

(

See programming notes

)

Programmable Tone Generation Time

00 = Disabled

01-09 = 100-900 ms

10-99 = 1.0 – 9.9 secs.

Telephone Line Monitor

1st Entry

0 = Immediate detection (approx. 10 sec. detection time)

1 - 4 = Delayed detection (delay in minutes)

2nd Entry

0 = No response (phone line monitor disabled)

1 = Keypad display only

2 = Keypad display and keypad trouble sound

3 = Keypad display and keypad trouble sound, when disarmed. Alarm, when armed

AUX Function/Manual Message

0 = Aux key performs defined function (macro)

1 = Aux key sends a voice message to Follow Me reminder phone number

Event Log 80% Full Report Code

(See programming notes)

Event Logging Options

0 = No event logging

1 = log Alarm/Alarm Restore

2 = log Trouble/Trouble Restore

4 = log Bypass/Bypass Restore

8 = log Open/Close x = log combination of events (add value of entries)

Audio Alarm Verification (AAV)/Remote

Phone Control

0 = none

1 = AAV and remote phone control

2 = remote phone control only

4 = AAV only

Notes (1) Audio Alarm Verification will only function when

Contact ID® is selected.

(2) AAV and Remote Phone Control features can only be used if the central station or remote phone supports DTMF commands.

LYNXR-IE Installation and Setup Guide

Data Field Descriptions

Sent when the test mode is exited. A restore code entered here will cause a restore message to be sent when Test mode is exited.

This field is used to set the time delay between when a connection is established on a Radio (digital communication with voice capabilities) session to when the 2100 Hz “training” tone is terminated. Enter any digit between 00 and 99.

Note: This field only applies when a GSMVL radio is installed in the control. Otherwise, enter “00” to disable.

An event (CID 351) is logged when system detects a Telco fault.

Upon restore, report is sent and the event is logged. The phone line monitor is zone 94.

First entry defines phone line failure detection time.

Second entry defines response to phone line failure.

If “0” is entered, user can define a macro function for the AUX key. See user manual for description of the use of this key.

If “1” is entered the system will send manually activated messages if Option 1, 3 or 4 has been selected in Field *48 for at least one of the report channels. The Follow Me reminder uses the PSTN line if at least one of the report channels uses the

PSTN line. Otherwise the reminder will be sent using the GSM

Vocal line.

The manual follow me system announcement is a repeatable

“System, System…..”.

Note: A macro cannot be run from the Test mode.

If an Event Logging selection is made in field

✻90, a message can be sent to the central station receiver when the log is 80% full. If the log becomes full, a new message will overwrite the oldest message in the log.

Note: All control and readout from the log, aside from the selection made by the installer in field ✻90, is accomplished via the downloader.

Example: To select “Alarm/Alarm Restore” and “Open/Close,” enter 9 (1 + 8); to select all events, enter #15.

Default “3” = alarm/alarm restore (1) plus trouble/trouble restore

(2).

The system has the ability to record various events in a history log (84-event capacity). The types of events to be logged can be selected as indicated. At any time, the downloader operator can then upload the log and view or print out all or selected categories of the log. The log can also be cleared by the download operator.

The display/printout at the central station will show the date, time, event, and description of the occurrences.

Note: System messages are logged when any non-zero selection is made.

This option is used to enable the Audio Alarm Verification and/or the Remote Phone Control features.

Notes: (1) In order to activate the Remote Phone Control feature and defeat an answering machine, ensure that the correct ring detection count (“15”) has been programmed in field ✻95.

(2) Remote phone session will be terminated if a report must be sent.

(3) If an alarm will be reported to primary and secondary phone numbers, AAV can only function via the secondary number.

- 23 -

LYNXR-IE Installation and Setup Guide

Data Field Descriptions

92

93

Number of Reports In Armed Period

0 = reports limited to a total of 10

1 = unlimited number of reports

Flexible Callback

0 = no flexible callback

1 = last digit flexible

2 = last 2 digits flexible

3 = last 3 digits flexible

This option can be used to limit the number of messages (alarm

& alarm restore reports) sent to the central station in an armed period.

Note: This field does not apply if SMS or IP Digital report formats have been selected in field *48.

Note: This feature only applies to telephone downloading

If enabled, the control will ignore the last 1, 2, or 3 digits of the programmed callback number (field

✻94) during a single download session. This allows the download operator to temporarily change the callback phone number by the number of digits selected, which allows the control to call back similar, but different numbers during a single session. For example, if downloading to a large number of controls, the operator can command the controls to call back phone numbers 555-1111, 555-

1112, 555-1113, etc., thus spreading the communications among several computers.

DOWNLOAD INFORMATION (

94,

95)

94

95

Download Call Back Phone Number

Enter up to 20 digits as follows: 0–9, # +11 for “

*

”, #

+ 12 for “#”, # + 13 for a pause.

Ring Detection Count For Downloading/

Remote Phone Control

0 = disable station initiated download and remote phone

1-14 = number of rings before control picks up phone line

15 = defeat answering machine

This is the phone number the control will use to call back the downloading computer.

Do not fill unused spaces. End field by pressing

✻. To clear entries from field, press

✻94✻.

Enter “15” to select defeat answering machine mode. If an answering machine is on the premises, you need to dial the premises and hang up on the first ring. Wait at least five (5) seconds (but no more than 22 seconds) and dial the premises phone number again. The control will pick up and announce

“SYSTEM ENTER CODE” every three seconds.

Note: To enter a number higher than 9 you must first press the [#] key.

OTHER PROGRAMMING COMMANDS

56

ENHANCED ZONE PROGRAMMING MODE

Interactive menu mode used for programming zone attributes and report codes. Refer to the

56

Enhanced Zone Programming Mode section for procedure.

80

DEVICE PROGRAMMING MENU MODE

Interactive menu mode for programming Powerline Carrier Devices. Refer to the

80 Device

Programming Menu Mode section for detailed procedure.

81

ZONE LISTS MENU MODE

Interactive menu mode for programming zone lists for Powerline Carrier Devices. Refer to the

81

Zone List Menu Mode section for detailed procedure.

83 ENHANCED

Interactive menu mode used to enter RF transmitter serial numbers. Refer to the

83 Enhanced

Sequential Mode section for detailed procedure.

84

ASSIGN ZONE VOICE DESCRIPTORS

Interactive menu mode used to assign descriptors to each zone. These descriptors will be announced whenever the system announces an event involving a zone.

85

96

RECORD CUSTOM VOICE DESCRIPTORS

Interactive menu mode used to record custom descriptors for use with each zone.

INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. NO. FOR

DOWNLOADING

96 initializes the system for downloading.

97

SET ALL PROGRAM FIELDS TO 1 OF 4 SETS OF DEFAULT VALUES

See Default Tables at the end of this manual.

98

99

EXITS PROGRAMMING MODE

Prevents re-entry by: Installer Code + 8 + 0 + 0; allows re-entry only by Power-up, then [

EXITS PROGRAMMING MODE

Allows re-entry to program mode by: Installer Code + 8 + 0 + 0; or by Power-up, then [

] and [#].

] and [#].

- 24 -

LYNXR-IE Installation and Setup Guide

56 Enhanced Zone Programming Mode

This is an interactive menu mode that is used to program zone numbers, zone types, alarm and report codes, and to identify the type of loop input device. This mode can also be used for entering Secom Series transmitter serial numbers.

Note: There are two methods for entering transmitter serial numbers. The first method is by using ✻56 Enhanced Zone Programming mode

(described below). The second method is by using ✻83 Enhanced Sequential Mode. Note that the ✻83 Enhanced Sequential Mode requires that all zone information first be entered using ✻56 Enhanced Zone Programming mode.

1C

1d

1E

1F

E

F

1A

1b

C d

You must refer to these instructions or to the Program Form while programming the system because the keypad display does not show prompt titles. Instead, prompts are indicated by a number/letter combination.

The prompts for ✻ 56 are as follows:

A 02 Zone Number----------------------- for entering the zone number b Zone Type ------------------------- for entering zone type

Report Code------------------------- for entering the zone’s report code

Input Type ------------------------- for entering the transmitter’s input type

Loop Number----------------------- for entering the transmitter loop number

Delete Serial Number? ---------- For deleting existing serial number

Enroll Mode? ----------------------- Selects serial number enroll mode

Serial Number --------------------- for entering transmitter’s serial number

Voice Descriptor?------------------ Selects voice descriptor mode

Descriptor 1------------------------- for entering first descriptor word

Descriptor 2------------------------- for entering second descriptor word

Descriptor 3------------------------- for entering third descriptor word

- 25 -

LYNXR-IE Installation and Setup Guide

56 Enhanced Zone Programming Mode

While in Program mode, press

56 to enter Zone Programming Menu Mode.

Refer to the zone assignment table for ✻ 56 on the separate programming form. The following explains the ✻ 56 prompts in detail. The left two columns identify the prompts and list the available entries for each. The rightmost column provides a further explanation of the entries.

If you are enrolling a CSK800HF Keypad refer to the “Enrolling the CSK800HF Monodirectional Keypad” section.

A 02

B

C

zt rc d i

Zone number

02-41, 95, 96, 99 = Zone number

[✻] = continue

00 = exit Zone Programming mode

Zone type

00-24 = zone type

[✻] = continue

[#] = return to previous prompt

Note: If 00 is accepted as a zone type, save the 00 zone type and advance to the confirm delete prompt (F).

Report code

Enter the report code for this zone.

[✻] = continue

[#] = return to previous prompt

Input type

3 =RF (supervised RF) – sends periodic check-in signals, faults, restore and low battery signals

4 = UR (unsupervised RF) – sends same as

“RF” type, but control does not supervise the check-in signals

5 = BR (button type) – sends only fault and low battery signals; does not send restores or check-in signals

[✻] = continue

[#] = return to previous prompt

Note RF type transmitters must remain within range of the receiver, otherwise a supervision failure signal will occur. UR and BR type transmitters may be carried off premises (out of range without causing a supervision failure.

Enter the 2-digit zone number to be programmed and the Voice

Descriptor for the selected zone number will be announced, if it is programmed. Press [

✻] to advance.

Zones 02-25 = RF zones (only)

Zones 26-41 = Button zones (only)

Zone 92 = Duress

Zone 94 = Phone Line Monitor

Zone 97 = Case Tamper

Zones 95, 96, 99 = Panic zones

Pressing 00 exits mode, upon which the prompt “56” blinks, indicating the mode is inactive. Press [

✻] + any field number to go to that field.

Each zone must be assigned to a zone type, which defines the way in which the system responds to faults in that zone. Enter the 2-digit zone type for this zone as follows:

00 = Not Used 08 = 24 Hr Aux

01 = Entry/Exit #1

02 = Entry/Exit #2

09 = Fire without verify

10 = Interior w/Delay

03 = Perimeter

04 = Interior Follower

20 = Arm–Stay

21 = Arm–Away

05 = Trouble Day/Alarm Night 22 = Disarm

06 = 24 Hr Silent

07 = 24 Hr Audible

If you are enrolling…..

23 = No Alarm Response

24 = Silent Burglary

Program as …..

DOD800GY Door/Window Sensor ZT 03 (Perimeter)

IRX800GY, IR800PIGY,

IRPI800M Motion Sensor

ZT 04 or 10 (Interior)

DTO800HF Heat/Smoke Detector ZT 09 (Fire)

TC805HF Remote Keyfob

IRX800GY, IR800PIGY, IRPI800M

Motion Sensor OR

DOD800GY Door/Window Sensor OR

DTO800HF Heat/Smoke Detector

ZT 20 (Arm-Stay)

ZT 21 (Arm-Away)

ZT 22 (Disarm)

ZT 23 (No Alarm Response)

Refer to the Installation Guide provided with the wireless device for additional information.

Report codes consist of 2 hexadecimal digits, each in turn consisting of 2 numerical digits. To enter report code of “3C”, enter [0] [3] for “3” and [1][2] for “C”.

Note: If this is Zone 95, 96 or 99, the system skips to the VOICE

DESCRIPTOR prompt (1C).

Enter the input type for the transmitter assigned to this zone.

Refer to the transmitter’s instructions for input types of each transmitter.

If you are enrolling….. Program as …..

3 (Supervised RF)

TC805HF Remote Keyfob 5 (BR Button Type)

Note: Zones 2-25 should be assigned Input Type 3 or 4. Zones 26-41 should be assigned Input Type 5 only.

- 26 -

E

l

LYNXR-IE Installation and Setup Guide

56 Enhanced Zone Programming Mode

Loop number or Loop and Serial

This prompt can be used to enroll loop number and serial number via RF transmission or the loop number can be enrolled

number (if using RF Learning)

1-4 = loop number for the zone of the transmitter being entered.

0 + [✻] = continue to DELETE ZONE

PARAMETERS CONFIRMATION prompt (F)

[✻] = continue to the ENROLL MODE prompt (1A) if not entered, or VOICE

DESCRIPTOR prompt if already entered

[#] = return to previous prompt manually. If using the RF Learning Mode, there is no need to manually enter a loop number. Proceed directly to RF Learning

Note: BR type devices cannot be enrolled by using UR or RF type.

Likewise, UR or RF type devices cannot be enrolled by using a BR type device. There is a 52-second time-out for RF enrolling. At the end of the time-out, the system returns to the INPUT TYPE prompt

(d). If enrolled, loop number and “L” are displayed.

RF Learning – Two (2) transmissions (2 key depressions) at least 5 seconds apart will be required for BR type devices

(device type 5). Two beeps will sound after the second transmission, confirming that the loop number and serial number have been learned.

For UR or RF type devices, four (4) transmissions are required

(fault, restore and fault, restore). A single beep will sound after the second transmission confirming that the loop and serial number have been captured. Following the fourth transmission the system will confirm that the loop number and serial number have been learned and announce the Voice Descriptor for the zone, if it is programmed, followed by two beeps. Press

[

✻] to continue.

With the exception of the panic function, the TC805HF does not transmit until the buttons have been released. The panic functions transmit as soon as the two-button combination is depressed. Each button of the keyfob must be enrolled individually.

If you are enrolling….

Transmit two fault, restore

(open, close) sequences by....

IRX800GY, IR800PIGY,

IRPI800M Motion Sensor

OR

DOD800GY Door/Window

Sensor

DTO800HF Heat/Smoke

Detector

Faulting the sensor’s tamper switch. Refer to the Installation

Guide provided with the wireless device for additional information.

1. Insert the detector head into the base by turning it clockwise. This will activate the tamper switch.

2. Wait 10 seconds.

3. Unscrew the detector head by turning it counterclockwise.

4. Repeat steps 1 – 3 to confirm the serial number.

TC805HF Remote Keyfob

Pressing and and releasing the selected button. Wait approximately four seconds before pressing the button again.

The “fifth” (panic) button transmits with a different serial number. To enroll the phantom

“fifth” button, press and hold both “SOS” buttons.

Manual Entry – Enter the desired loop number and press [

✻] to continue (see the transmitter’s Installation Instructions for specific loop designations).

Note: The loop number can be changed even if the zone has already been entered. Care should be taken when using this feature as it has the capability to make zones inoperable by creating a mismatch of a working serial number/loop number combination.

This should be re-confirmed if the loop number is changed.

“L” indicates that the zone’s serial number has already been enrolled.

- 27 -

LYNXR-IE Installation and Setup Guide

56 Enhanced Zone Programming Mode

F

Delete zone parameters confirmation

0 = discard the delete request

1 = confirm requested delete

Note: If 00 was entered as a zone type in prompt (b),

00 will be retained and system will advance to prompt (1C).

This function deletes either the serial number or all zone information that is programmed for the zone.

If “00” was entered in the zone type, the confirmation of the delete request will delete all information associated with the zone currently being programmed.

IA LC

Enroll mode

0 = advance to the VOICE DESCRIPTOR prompt (1C).

Note: This will save all zone parameters.

1 = enter now and proceed to SERIAL

NUMBER prompt (1b).

Note: Not applicable if the serial number is already present.

2 = copy the last serial number entered into local ram.

Note: If this is the 1st zone, none will be in the buffer and the panel will emit a long tone. Not valid if serial number is already present.

3 = view existing serial number.

Note: Only if “L” is displayed. If “L” is not displayed, panel will emit a long beep.

9 = advance to F; delete existing serial number.

Note: Only if “L” is displayed. If “L” is not displayed, panel will emit a long beep.

[✻] = advance to the VOICE DESCRIPTOR prompt (1C). This will save all zone parameters.

[#] = return to the LOOP NUMBER prompt (E).

Note: In order for all entered parameters to be accepted, you must advance to the VOICE

DESCRIPTOR prompt (1C).

If “0” was entered in the loop number, the confirmation of the delete request will delete the serial number of the zone currently being programmed.

If “L” is displayed, the serial number for this transmitter has already been entered. It may, however, still be viewed, confirmed (only if in listen mode), or deleted.

View serial number

Enter “3”. Each digit will be redisplayed, and the keypad will beep once for digits 1-6, and three times for the last digit.

Confirm serial number

The serial number/loop number combination can be confirmed after one transmission from a BR type device or two transmissions (fault and restore) from a UR or RF type device.

If a transmission is received that matches the serial number and loop number entered, the system will confirm the reception by announcing the Voice Descriptor for the zone, if it is programmed, followed by three beeps, and a “C” will appear on the display indicating the received serial number and loop number have been confirmed. No further transmissions will be received.

Delete serial number

The serial number can be deleted by entering “9”.

If “L” is not displayed, the serial number for this transmitter has not been previously entered. You may enter the serial number manually, copy the previous serial number, return to

Prompt (E) or enter the serial number later using the

✻83

Enhanced Sequential Mode.

Manual entry

Enter “1” to advance to Serial number prompt (1b).

Copy the previous serial number

Enter “2” to copy the previous serial number entered.

Return to Prompt (E)

Enter “#” to return to Loop Number prompt (E).

Enter transmitter later

Enter “0” or “

✻” if you wish to enter the transmitter later, using the

✻83 Enhanced Sequential Mode described later in this manual.

Notes: (1) The panel will listen only when it is in the idle loop waiting for key entry and a serial number has been entered. If a key is entered, the function must be completed and the panel will listen again.

(2) A long beep indicates illegal entry or duplicate serial number/loop entry

- 28 -

Ib

IC

Id

IE

vi

IF

vi vi

LYNXR-IE Installation and Setup Guide

56 Enhanced Zone Programming Mode

Serial number

Enter the transmitter’s 7-digit serial number.

[#] = return to prompt 1A and reject any serial numbers entries that have been made.

[✻] = return to prompt 1A, (if a valid serial number has been entered, the “L” is displayed and the serial number will be copied into EEROM from the last serial entered into the buffer.)

Note: This prompt can be used only to manually enroll a serial number. RF enrollment will be rejected and the current zone descriptor will be announced, followed by a single long beep and the system will return to prompt (1A).

In this mode, the transmitter serial numbers can only be entered manually.

Enter the 7-digit serial number printed on the transmitter. If an incorrect digit is entered, press the [#] key to backup to prompt (1A) and start over. When all 7 digits are entered, press the [

✻] key.

If 52 seconds passes and no entry has been made, the system returns to prompt (1A).

Notes/1) If the serial and loop number combination is already present the keypad will emit a single long beep and the system will return to the (1A) prompt and “L” will be displayed.

(2) If less than 7 digits have been entered, the keypad will emit a single long beep and return to the (1A) prompt without displaying the “L”.

(3) If more than 7 digits have been entered, the first 6 digits will be saved along with the last digit that was entered (entering

123456789 yields the serial number 1234569).

Each zone can have a voice descriptor of up to 3 words that will be announced whenever the system announces status for that zone.

Voice descriptor

0 = skip to next zone (A)

1 = enter descriptor mode; existing descriptor for this zone will be announced

Descriptor 1

Enter [#] + 2-digit vocabulary index number† of first descriptor word for this zone.

6 = accept word and advance to descriptor 2

(descriptor 2 will be announced)

8 = accept word and advance to next zone

(prompt A) – entire zone descriptor will be announced

Press any other key to repeat the selected word.

Descriptor 2

Enter [#] + 2-digit vocabulary index number† of second descriptor word for this zone.

6 = accept word and advance to descriptor 3

(descriptor 3 will be announced)

8 = accept word and advance to next zone

(prompt A) – entire zone descriptor will be announced

Press any other key to repeat the selected word.

Descriptor 3

Enter [#] + 2-digit vocabulary index number† of third descriptor word for this zone.

6 or 8 = accept word and advance to next zone (prompt A) – entire zone descriptor will be announced

Press any other key to repeat the selected word.

† see

84 Assign Zone Voice Descriptors section for vocabulary index

Use the [6] or [8] key to advance as described.

To change the entered index number before pressing [6] or [8], simply press [#] + desired 2-digit vocabulary index number.

If descriptor 1 is not desired, enter [#] + 99 (blank), then press

[8] to return to zone number prompt.

† see

84 Assign Zone Voice Descriptors section for vocabulary index

Use the [6] or [8] key to advance as described.

To change the entered index number before pressing [6] or [8], simply press [#] + desired 2-digit vocabulary index number.

If descriptor 2 is not desired, enter [#] + 99 (blank), then press

[8] to return to zone number prompt.

† see

84 Assign Zone Voice Descriptors section for vocabulary index

Use the [6] or [8] key to advance as described.

To change the entered index number before pressing [6] or [8], simply press [#] + desired 2-digit vocabulary index number.

If descriptor 3 is not desired, enter [#] + 99 (blank), then press

[8] to return to zone number prompt.

- 29 -

LYNXR-IE Installation and Setup Guide

80 Device Programming Menu Mode

Powerline Carrier devices (e.g.; X10 brand devices) are programmable switches that can be used to perform many different functions. They can be used to turn lights on and off, control sounders, or for status indications. In this system, each device must be programmed as to how to act (ACTION), when to activate

(START), and when to deactivate (STOP). Each of these is described below.

The control supports a total of 8 output devices.

The K10145X10 transformer sends signals from the control panel through the premises AC wiring to the

Powerline Carrier Devices (which are plugged into AC outlets). Devices plugged into Powerline Carrier

Devices can then be made to perform various functions in response to commands entered at the keypads in the security system.

Programming Options Defined

The following will help you understand the programming of output devices when using ✻ 80 and ✻ 81 modes.

ACTION The “ACTION” of the device is how the device will respond when it is activated by the

“START” programming. There are four different choices of actions:

• ACTIVATE for 2 SECONDS and then reset.

• ACTIVATE and REMAIN ACTIVATED until stopped by some other event.

• PULSE ON and OFF until stopped by some other event.

• NOT USED when the device is not used.

START

The “START” programming determines when and under what conditions the device will be activated. The following START options are available:

Start by Event

1. Event is the condition (alarm, fault, trouble) that must occur to a zone or group of zones (zone list) in order to activate the device. These conditions apply only when a zone list is used. The different choices for “EVENT” are listed below and in the

“Programming Powerline Carrier Devices” paragraph that follows.

• ALARM Device activates upon any alarm in an assigned zone in the zone list.

• FAULT Device activates upon any opening or short in an assigned zone in the zone list.

• TROUBLE Device activates upon any trouble condition in an assigned zone in the zone list.

• NOT USED Device action is not dependent upon one of the above events.

2. A zone list is a group of zones to which the “EVENT” applies in order to activate a particular device. Note that there are a total of 3 output device-related zone lists that can be programmed in ✻ 81 menu mode; when the selected EVENT (alarm, fault or trouble) occurs in any zone in the selected “Start” ZONE LIST (1, 2, or 3), activation of the selected device will START.

Start by Zone Type or System Operation

• If a system operation, such as “DISARMING” or “ANY FIRE ALARM,” is to activate the device, the appropriate choice would also be entered under the

“ZONE TYPE” option. “ZONE TYPE” is used independently of the

“EVENT/ZONE LIST” combination.

• If a “ZONE TYPE” is chosen, any zone of that response type going into alarm, trouble, or fault will cause the device to activate as selected in “ACTION.” If the same “ZONE TYPE” is also chosen for the STOP programming, any zone of that type that restores will de-activate the device.

• If a “SYSTEM OPERATION” is chosen (e.g., End of Exit Time), that operation will cause the device to activate as selected in “ACTION.” The different choices for “ZONE TYPE” and “SYSTEM OPERATION” are listed in the “Start zone type” paragraphs later in this section, and in the Programming Form.

- 30 -

LYNXR-IE Installation and Setup Guide

80 Device Programming Menu Mode

STOP

The “STOP” programming determines when and under what conditions the device will be deactivated. The following options are available:

Upon Restore of a Zone List

Restore Zone List: If a “ZONE LIST” is used as the “Stop” event, the device will de-activate when all the zones in that list restore from a previous fault, trouble, or alarm condition. This will occur regardless of what is programmed to “START” the device; therefore, a “RESTORE ZONE LIST” would normally only be used when a “ZONE LIST” is used to start the device.

Upon a Zone Type or System Operation

Zone Type/System Operation: Instead of using a “RESTORE ZONE LIST,” a specific zone (response) type or system operation action can be selected to de-activate the device.

• If a specific “ZONE TYPE” is chosen, any zone of that response type that restores from a previous alarm, trouble, or fault condition will cause the device to de-activate.

• If a “SYSTEM OPERATION” is chosen, that operation will cause the device to de-activate.

During normal system operation, any devices may be manually started by keypad entry of: Code* + [#]

+ 4 + “n;” or manually stopped by keypad entry of: Code* + [#] + 7 + “n,” where “n” = the device number to be controlled.

* Code is required for devices 7 and 8. For devices 1-6, code is not required. See User Manual for more information.

Programming Powerline Carrier Devices

While in program mode, press

80 to enter Output Device Menu Mode. This mode is used to program all output devices used in the system. Refer to the output device table for ✻ 80 on the separate programming form when programming output devices.

Note: The House ID of the Powerline Carrier Devices must be entered in data field

25.

The prompts for

80 are as follows:

Powerline Carrier Device Programming Main Menu prompt b

C d

80

A 01 Device Number --------- for entering the device number

Device action ------------ for defining the action the device will perform when active

Start Event Type ------- for assigning the event type to start the action

Start Zone List ---------- for assigning the zone list to start the action

E

F

1A

Start Zone Type--------- for assigning the zone type to start the action

Stop Zone List ----------- for assigning the zone list to stop the action

Stop Zone Type---------- for assigning the zone type to stop the action

- 31 -

LYNXR-IE Installation and Setup Guide

80 Device Programming Menu Mode

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Note: Entering a number other than one specified will give unpredictable results.

80

A

B

C

0I

aa et

Powerline Carrier Device

programming

0 = exit mode

1 = enter mode

Device number

01-08 = device number to be programmed

[✻] = continue

00 = exit Device Programming mode

Device action

0 = No response

1 = Close for 2 seconds

2 = Close and Stay Closed

3 = Continuous Pulse on & off (1 sec ON, 1 sec

OFF)

[✻] = continue

[#] = return to previous prompt

Start event type

0 = Not used

1 = Alarm

2 = Fault

3 = Trouble

[✻] = continue

[#] = return to previous prompt

Entering “1” advances to the next prompt below.

Entering “0” exits mode, upon which this prompt blinks, indicating the mode is inactive.

Enter device numbers as 2-digit entries.

Enter the 1-digit action (0-3) for the device being programmed (current action is displayed).

Notes: (1) If “3” is entered (pulse), only up to 3 different devices can be pulsed if one of the devices is a siren/horn (X10

Powerhouse Security model SH10A). In addition, the siren/horn cannot be manually activated using the lights on/lights off keypad commands.

(2) If using an X10 Powerhouse Security SH10A siren:

• you must use device action “3.”

• you must change the device action default to “3” if using default Table 2 or 4

Enter the 1-digit event type (0-3) to activate the device being programmed. A zone list must be used in conjunction with an event. If a zone type/system operation is to be used instead of an event, enter “0”.

D

zl

Start zone list

1-3 = zone list number (to be programmed in field ✻81)

0 = zone list not used for this device

[✻] = continue

[#] = return to previous prompt

If a zone list will be used to start the device action, enter the zone list number at this prompt.

E

zt

Start zone type

01-58 = zone type to start this device action

(select only those that are applicable)

00 = zone type not used for this device

[✻] = continue

[#] = return to previous prompt

If a zone type or system operation will be used to start the device action, enter the appropriate 2-digit code for the device being programmed (see table that follows).

Choices for zone types

00 = Not Used 04 = Interior Follower 08 = 24 Hr Aux

01 = Entry/Exit #1 05 = Trouble Day/Alarm Night 09 = Fire

02 = Entry/Exit #2 06 = 24 Hr Silent

03 = Perimeter 07 = 24 Hr Audible

10 = Interior w/Delay

24 = Silent Burglary

Choices for system operation

20 = Arming–Stay 33 = Any Alarm (except zt 08 & 09)

36 = At Bell Timeout**

42 = Sys. Batt. Low

21 = Arming–Away

22 = Disarm. (Code

+ OFF)

31 = End of Exit

Time

32 = Start of Entry

Time

38 = Chime

39 = Any Fire Alarm

40 = Bypassing

43 = Comm. Failure

52 = Kissoff

58 = Duress

** Or at Disarming (which ever occurs earlier)

F

IA

zl zt

Stop zone list

1-3 = zone list to stop this device action

0 = zone list not used

[✻] = continue

[#] = return to previous prompt

Stop zone type

01-58 = zone type to start this device action

(select only those that are applicable)

00 = zone type not used for this device

[✻] = continue

[#] = return to previous prompt

If a zone list will be used to STOP, or restore, the device action, enter the zone list number 1, 2, or 3 (to be programmed in

✻81 mode). If not used, enter “0”.

If a zone type or system operation will be used to STOP the device action, enter the appropriate 2-digit code (see the “ZT” choices listed above). If not, enter 00.

The display then returns to the DEVICE NUMBER prompt

(A) so that you can enter the next device number to be programmed, or enter [0][0] to end device programming.

- 32 -

LYNXR-IE Installation and Setup Guide

81 Zone List Menu Mode

While in Program mode, press

81 to enter Zone List Menu Mode. This mode is used to program zone lists for output devices (programmed in

80 menu mode) or Chime-by-Zone in Zone List 3.

NOTES:

• Any list may include any or all of the systems zone numbers.

• A zone list can be assigned to more than one Powerline Carrier Device.

The prompts for *81 are as follows:

81 Zone List Programming -------------------- Main Menu prompt

A 01 b

Zone List Number --------------------------- for entering the zone list number to be programmed

Zone Entry to List --------------------------- for entering zones to the assigned zone list

C Delete Entire List? -------------------------- For deleting the entire zone list and its contents d Delete Specific Zones From List?-------- Selects whether to delete zones or return to next zone

E Delete Zones ----------------------------------- for deleting specific zones from the current zone list

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Notes: (1) Entering a number other than one specified will give unpredictable results.

(2) Do not assign zones with zone types 20, 21 or 22 to a zone list.

8I

Zone list programming

0 = exit mode

1 = enter mode

Pressing 1 advances to the next prompt below.

Pressing 0 exits mode, upon which this prompt blinks, indicating the mode is inactive.

A 0I

Zone list number

01-03 = zone list number to be programmed

00 = exit Zone List mode

[✻] = continue

Enter the Zone List Number 01, 02, or 03 to program (or 00 if no zone lists are used).

B

zz

Zone entry to list

01-41, 95, 96, 99 = zone numbers to add to zone list

[✻] = accept zone number and enter the next zone number

00 = accept zone number(s) and continue to next prompt

Enter each zone number to add to the zone list by first entering the zone number, then the [

✻] key (for example,

01

✻ 02✻ 03✻). The system will announce the Voice

Descriptor for the selected zone, if it is programmed. After all desired zones are enrolled, enter “00” to advance.

C

Delete entire zone list?

0 = don’t delete; continue to next prompt

1 = delete the current zone list

To delete the zone list, enter “1”. All zones in the zone list will be deleted automatically and programming will return to the ZONE LIST NUMBER prompt.

To save the zone list or delete specific zones from the list, enter “0”.

D

Delete zones from list?

1 = continue to delete zones prompt

0 = don’t delete; continue to next zone list number prompt (A….01)

[#] = return to zone list number prompt (A….01)

E

Delete zones

Enter each 2-digit zone number to be deleted from the current zone list, followed by the [✻] key.

[✻] = delete zone and enter next zone to be deleted

00 = delete zone and return to next zone list number prompt (A….01) desired

To save the entire zone list, enter “0” and programming will return to the ZONE LIST NUMBER prompt.

To delete a zone or zones in a zone list enter “1”.

When deleting a zone(s) from the zone list, if the selected zone has a Voice Descriptor programmed, upon deletion it will be announced as a confirmation that it has been deleted. After all zones to be deleted are entered, enter “00” to return to the ZONE LIST NUMBER prompt so that another list can be programmed, if desired.

- 33 -

LYNXR-IE Installation and Setup Guide

83 Enhanced Sequential Mode

By using this mode, you can add, delete, or change the serial number of a transmitter in a zone, but retain all other existing data that has been programmed for that zone. Note that the ✻ 83 Enhanced Sequential mode requires that all zone information must first be entered using the

56 Enhanced Zone Programming mode for all zones below zone number 26 (4 button key area).

Note: Any zone which already has a serial number learned in will not be accessible in ✻83 Enhanced Sequential mode!

Certain button-type transmitters have more than one button (e.g.; TC805HF). Note that each button must be assigned to a different zone. Similarly, the DOD800GY Transmitter has contact terminals and a reed switch for use with a magnet. If using both, each must also be assigned to a different zone.

This means that the procedures that follow must be repeated for each button-type zone below zone number

26 or contact on the transmitter. Four zone button-type devices are held in zones 26 and above. They will be started on boundaries of zones 26, 30, 34, and 38. These four zone button-type devices will have the option to have all information entered in this field. One entry will set the loop number, report code, zone type, and input device type for all 4 buttons, and a second entry will enter one serial number into four zones.

Note: Use this mode only after all other zone information has been programmed, including transmitter loop numbers except for button-type zones over zone number 26. The panel will stop at zones 26, 30, 34 and 38 and zone data can be entered as a default here.

Enter Serial Number Sequential mode by pressing

83. The prompts for

83 are as follows:

Zone Number -----------------------for entering the zone number to be programmed A 02

1A

1b

Enroll Mode -------------------------Selects method of serial number or viewing

Enroll Serial Number ------------for entering transmitter serial numbers

F Delete Serial Number ------------for deleting existing serial numbers

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Notes: (1) Entry of a number other than one specified will give unpredictable results.

(2) In Enhanced Sequential Mode, 4 button type keys will always be enrolled simultaneously. They will be stopped at the 4 button boundaries of 26, 30, 34 and 38, provided the zone is free of a serial number. If the first zone of the key has a serial number enrolled, the remaining keys cannot be programmed in sequential mode. In addition, if the zone has not been set up (duplicate loop, missing zone type, etc.) only entries 0 (skip to the next zone) and 4 (copy the key template) will be allowed.

(3) You may find it convenient to adjust the volume setting before entering the Programming Mode. This will allow you to clearly hear feedback announcements or system beeps.

A 02

Zone number

Enter the 2-digit zone number.

[✻] = continue; system searches for zones not yet entered (for zones 2 through 25 a zone type must be entered), then advances to

ENROLL SERIAL NUMBER prompt “1b”

00 = exit Sequential mode

Enter the 2-digit zone number of the first transmitter to have its serial number entered. The system will announce the Voice

Descriptor for the selected zone number, if it is programmed.

Press [

✻] to continue. Starting with this zone number, the system will search for the first transmitter that has all of the following attributes pre-programmed in

✻56 ENHANCED

ZONE PROGRAMMING: a) Make sure that the appropriate input type was selected in

✻56 (RF,

UR, or BR programmed) b) Make sure that the appropriate loop number was selected in

✻56. c) No serial number programmed d) Zone type

If the first zone number entered does not have one or more of the above attributes, the system will search its database for the first zone that does, and will display it at the enroll

SERIAL NUMBER prompt (1b).

Pressing 00 exits mode, upon which the prompt “83” blinks, indicating the mode is inactive.

Note: Two exceptions to the requirement above exist for keys. Four zone button type devices (zone numbers 26, 30, 34, and 38) will be stopped only if there are no serial numbers enrolled in all 4 zones of the key, regardless of the attributes that have been entered. In addition, zone types are not required to be present. In this case,

1A, Option 4 must be selected prior to “Learn”.

- 34 -

IA

zz

IA LC

Ib

zz

Ib

LYNXR-IE Installation and Setup Guide

83 Enhanced Sequential Mode

Note: If “L” is displayed, the serial number for this transmitter has already

Enroll mode

0 = advance to next zone to be enrolled

1 = enter now and proceed to SERIAL NUMBER been entered however, it may still be confirmed, viewed or deleted.

If the transmitter’s serial number has not been previously prompt (1b).

For 4 button keys (zones 26-29, 30-33, 34-37, &

38-41) the serial number will be enrolled to all four entered, you may enter the enroll serial number mode (1A) by entering “1”, or copy the last serial number that was entered by entering “2”. buttons.

If enrolling a key, the panel will emit a long beep

If the transmitter’s serial number has been previously when entering a 1 to indicate that the present key set up is invalid.

Notes (1) A valid template or key has 4 existing zones, each with a zone type, unique loop number.

(2) If the display automatically advances to

“1A” rather than “1b” the configuration of the key is not valid. At that point copy template, skip, or return are the only legal entries. entered, you may, view the present serial number by entering

“3”. If view is selected each digit will be re-displayed, and the keypad will beep once for digits 1-6, and three times for the last digit. Once the serial number has been entered by either selecting a “1” or a “2”, you will return to this prompt with the

L” on the display.

The serial number/loop number combination that was entered can be confirmed by getting two transmissions (fault and restore) from the RF or UR device or one transmission from

2 = copy the previous serial number entry from the buffer.

Notes 1) Before you can copy a serial number you must first enter a serial number. If no serial is stored in the buffer and a copy is attempted the panel will emit a long beep indicating an invalid operation.

(2) Not applicable for 4 button key zones 26-29,

30-33, 34-37, & 38-41.

3 = view existing serial number.

Note: Only if “L” is displayed. If the “L” is not displayed the panel will emit a long beep.

4 = copy the 4 button key template that has been set in zone numbers 26-29 (all zone parameters except serial numbers). (Only valid on zones 30-33, 34-37, & 38-41 that do not have serial numbers enrolled.)

Notes (1) Template acceptance is indicated by two beeps after copying.

(2) A single long beep emitted when copying a indicates the template is not valid.

9 = delete existing serial. Go to the (1A) prompt.

For 4-button key, zones 26-29, 30-33, 34-37,

& 38-41 have serial numbers. Delete all four at one time.

Note: Only if “L” is displayed. If the “L” is not displayed the panel will emit a long beep.

[✻] = advance to next zone to be enrolled

[#] = return to previous prompt (A) the BR device. If a transmission is received that matches the serial number and loop number entered, the system will announce the Voice Descriptor for the loop followed by three beeps, and a “C” will be displayed indicating that the received serial number and loop number transmission has been confirmed to match. No further transmissions will be received.

When confirming a 4 button key, only the serial number is confirmed, since it assumed that all loops are used. Pressing any key will allow a confirmation.

Long beep indicates illegal entries, or duplicate serial

number/loop entry

When the last zone has been entered, the display will remain on that zone. To exit this mode and return to data field program mode, press 00 at the ZONE NUMBER prompt.

When all zones have been programmed, test each zone using the system’s Test mode. Do not use the Transmitter ID Sniffer mode for this, since it will only check for transmission of one zone on a particular transmitter, and not the zones assigned to each additional loop.

For Zones 26-29, 30-33, 34-37, and 38-41 any loop can be used for RF enrollment. If enrolling via RF, it will be confirmed without additional transmissions.

Serial number

Enter transmitter’s 7- digit serial number via RF learning or manually.

[#] = return to (1A) prompt and reject whatever serial number entries have been made.

[✻] = return to (1A) prompt (if a valid serial number has been enrolled, “L” is displayed and the serial number will be copied into

EEROM and the last serial entered buffer.

Note: For zones 26, 30, 34 and 38 only BR type devices can be used.

This prompt can be used to enroll the transmitter serial number via RF transmission or manually. If using the RF

Learning Mode there is no need to manually enter a serial number. Proceed directly to RF Learning. Upon entering the

Serial Number mode, the Zone Descriptors will be announced.

Note: BR type devices can be enrolled only by transmission from BR devices. Likewise, UR and RF devices can only be enrolled by transmission from a UR or RF device

RF Learning – Two (2) transmissions (2 key depressions) at least five seconds apart, will be required for BR type or four

(4) transmissions (fault, restore and fault, restore) for UR or

RF type. If the learned serial number has a different loop number than that entered in

✻56 the system will announce the Voice Descriptor, if it is programmed, followed by two beeps and will return to Prompt (1A) and “L” will be displayed.

- 35 -

LYNXR-IE Installation and Setup Guide

83 Enhanced Sequential Mode

For UR or RF type devices, four (4) transmissions are required

(fault, restore and fault, restore). A single beep will sound after the second transmission confirming that the loop and serial number have been captured. Following the fourth transmission the system will confirm that the loop number and serial number have been learned and announce the Voice

Descriptor for the zone, if it is programmed, followed by two beeps. Press [

✻] to continue.

If you are enrolling a IRX800GY, IR800PIGY or IRPI800M

Motion Sensor, or the DOD800GY Door/Window Sensor transmit two fault, restore (open, close) sequences by faulting the sensor’s tamper switch. Refer to the Installation Guide provided with the wireless device for additional information.

If you are enrolling a DTO800HF Heat/Smoke Detector transmit two fault, restore (open, close) sequences as follows:

1. Insert the detector head into the base by turning it clockwise. This will activate the tamper switch.

2. Wait 10 seconds.

3. Unscrew the detector head by turning it counterclockwise.

4. Repeat steps 1 – 3 to confirm the serial number.

With the exception of the panic function, the TC805HF does not transmit until the buttons have been released.

The panic functions transmit as soon as the two-button combination is depressed. Each button of the keyfob must be enrolled individually.

The “fifth” (panic) button transmits with a different serial number. To enroll the phantom “fifth” button, press and hold both “SOS” buttons.

If you are enrolling the TC805HF Remote Keyfob, transmit two fault, restore (open, close) sequences by pressing and and releasing the selected button. Wait approximately four seconds before pressing the button again.

If the loop number captured by RF transmission and that entered in

✻56 mode match, the system will announce the

Voice Descriptor, if it is programmed, followed by three beeps and return to Prompt (1A) and “LC” will be displayed. No additional transmissions are needed for confirmation

.

Manual Entry – Enter the 7-digit serial number printed on the transmitter. If you enter an incorrect digit, press the [#] key to backup to prompt (1A) and start over. When all 7 digits are entered, press the [

✻] key. If less than 7 digits are entered, the keypad will emit a single long beep and return to the (1A) prompt without displaying the “L”.

If more than 7 digits have been entered, the first 6 digits will be saved along with the last digit that was entered (entering

123456789 yields the serial number 1234569).

Note: If 52 seconds pass and no entry has been made, the system returns to prompt (1A).

F

Delete serial number

0 = discard the delete request

1 = confirm requested delete

Note: Entering a “9” at prompt (1A) will cause the panel to return to prompt (1A) regardless of the confirmation answer.

This function deletes only the serial number.

Entering a “9” at prompt (1A). Confirmation of the delete request will cause deletion of the serial number pertaining to the zone being programmed.

Note: In Enhanced Sequential Learn Mode, 4 button type keys will always be learned simultaneously. They will be stopped at the 4 button boundaries of 26, 30, 34 and 38, provided the zone is free of a serial number. If the first zone of the key has a serial number learned, the remaining keys cannot be programmed in sequential learn mode. In addition, if the zone has not been set up (duplicate loop, missing zone type, etc.) only entries 0 (skip to the next zone) and 4 (copy the key template) will be allowed.

- 36 -

LYNXR-IE Installation and Setup Guide

84 Assign Zone Voice Descriptors

Use this mode to assign voice descriptors for each zone. These are the descriptors that are announced when the system announces any event involving a zone number. Each descriptor can consist of up to

3 words. Press

84 while in Programming mode.

The prompts for

84 are as follows:

84

A 02 b

Voice Descriptors ----------------- Main Menu prompt

Zone Number----------------------- for entering the zone number to be programmed

Descriptor 1------------------------- for assigning the first word of this zone’s descriptor

C Descriptor 2------------------------- for assigning the second word of this zone’s descriptor d Descriptor 3------------------------- for assigning the third word of this zone’s descriptor

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Note: Entering a number other than the one specified will give unpredictable results.

A

B

C

84

zz vv vv

D vv

Assign zone voice descriptors

0 = exit mode

1 = enter mode

Zone number

[✻] = continue to next prompt (any existing descriptors will be announced, then descriptor 1 will be repeated)

00 = exit voice descriptor mode

Descriptor 1

Enter [#] + 2-digit vocabulary index number of first descriptor word for this zone.

6 = accept word and advance to descriptor 2

(descriptor 2 will be announced)

8 = accept word and advance to prompt (A) for next zone. Press any other key to repeat the selected word.

Descriptor 2

Enter [#] + 2-digit vocabulary index number of second descriptor word for this zone.

6 = accept word and advance to descriptor 3

(descriptor 3 will be announced)

8 = accept word and advance to prompt (A) for next zone. Press any other key to repeat the selected word.

Descriptor 3

Enter [#] + 2-digit vocabulary index number of third descriptor word for this zone.

6 or 8 = accept word and advance to prompt

(A) for next zone. Zone descriptor will be announced. Press any other key to repeat the selected word.

Pressing 1 advances to the next prompt below.

Pressing 0 exits mode, upon which this prompt blinks, indicating the mode is inactive.

Enter the 2-digit zone number for which this descriptor is being assigned, then press [

✻]. The Voice Descriptor for the selected zone will be announced, if it is programmed.

Enter the first word of the descriptor for the selected zone.

Use the [6] or [8] key to advance as described.

To change the entered index number before pressing [6] or [8], simply press [#] + desired 2-digit vocabulary index number.

If descriptor 1 is not desired, enter [#] + 99 (blank), then press

[8] to return to zone number prompt.

Enter the second word of the descriptor for the selected zone.

Use the [6] or [8] key to advance as described.

To change the entered index number before pressing [6] or [8], simply press [#] + desired 2-digit vocabulary index number.

If descriptor 2 is not desired, enter [#] + 99 (blank), then press

[8] to return to zone number prompt.

Enter the last word of the descriptor for the selected zone.

Use the [6] or [8] key to advance as described.

To change the entered index number before pressing [6] or [8], simply press [#] + desired 2-digit vocabulary index number.

If descriptor 3 is not desired, enter [#] + 99 (blank), then press

[8] to return to zone number prompt.

- 37 -

LYNXR-IE Installation and Setup Guide

84 Assign Zone Voice Descriptor

VOICE VOCABULARY INDEX

00 ½ second pause

A

82 ALARM

32 ATTIC

B

01 BABY

33 BACK

34 BASEMENT

35 BATHROOM

36 BEDROOM

C

83 CHECK

D

38 DEN

02 DETECTOR

03 DINING

04 DOOR

40 DOWNSTAIRS

05 DRIVEWAY

E

06 EAST

41 EIGHT

42 EMERGENCY

F

87 FIRE

45 FIVE

08 FLOOR

46 FOUR

47 FRONT

G

48 GARAGE

09 GUN

H

50 HALL

I

10 INSIDE

K

51 KITCHEN

L

11 LAUNDRY

52 LAUNDRY

ROOM

12 LIBRARY

13 LIVING

M

14 MAIN

15 MASTER

54 MASTER

BEDROOM

55 MEDICAL

84 MESSAGE

56 MOTION

DETECTOR

N

57 NINE

16 NORTH

58 NURSERY

O

59 OFFICE

60 ONE

17 OUTSIDE

P

61 PATIO

62 POLICE

18 POOL

R

63 REAR

19 ROOM

S

64 SECOND FLOOR

65 SEVEN

20 SHED

21 SHOP

66 SIDE

67 SILENT POLICE

68 SIX

69 SLIDING

22 SMOKE

23 SOUTH

24 STORAGE

85 SYSTEM

T

25 THIRD FLOOR

75 THREE

76 TRANSMITTER

77 TWO

U

78 UPSTAIRS

26 UTILITY

79 UTILITY ROOM

W

27 WEST

80 WINDOW

Y

28 YARD

Z

81 ZERO

86 ZONES

29 1

ST

30 2

ND

31 3

RD

99 Blank (for erasing a previously

programmed

word)

SYSTEM WORDS

AC LOSS

ARMED

AWAY

BYPASSED

CHIME

DISARMED

DISARM SYSTEM

NOW

EXIT NOW

FAULT

INSTANT

LOW BATTERY

NOT

READY TO ARM

STAY

Note: If button type device is used to Arm Away, Arm Stay, and disarm the system it is recommended to assign “Check” and

“Zones” voice descriptors to each of the three zones. This will allow the system to announce “Check Zones” “Low

Battery” if the button device has a low battery.

- 38 -

LYNXR-IE Installation and Setup Guide

85 Record Custom Voice Descriptors

Use this mode to record up to 5 custom voice descriptors. Press ✻ 85 while in Programming mode.

Note: Entering a number other than one specified will give unpredictable results.

85

A 7

d

Assign custom voice descriptors

0 = exit mode

1 = enter mode

Custom descriptor number

Enter 7 + d + [✻]

Where d = 0-4, each representing custom word 70, 71, 72, 73, or 74, respectively. Any existing word will be announced.

Press [#] to start recorder. Begin speaking immediately after the third beep.

Speak the desired word clearly near the microphone. Recording stops after 1.5 seconds.

6 = accept word and ready to record next descriptor prompt (A….7d)

[#] = re-record descriptor

00 = exit Record mode after pressing 6 to accept word

Press any key to repeat the recorded word.

Entering “1” advances to the next prompt below.

Entering “0” exits mode, upon which this prompt blinks, indicating the mode is inactive.

Record up to 5 custom words.

- 39 -

LYNXR-IE Installation and Setup Guide

Enrolling the CSK800HF Monodirectional Keypad

The following procedures should be used in conjunction with *56 Enhanced Zone Programming Mode and/or

*83 Enhanced Sequential Mode procedures.

Prior to enrolling the keypad in the LYNXR-IE Control Panel you must set up Security Codes and Prox Tags (if supported). No interaction with the panel is required. Refer to the Installation Instructions for the CSK800HF for additional information.

1 Install the CSK800HF in accordance with the Installation Instructions provided with the Keypad.

2. Enroll tamper and supervision functions as follows: a. Program as Zone Type 07 (24 Hr. Audible) b. Program as Input Type 04 (Unsupervised RF Transmitter) (UR-type) c. When prompted for the Serial Number, transmit two open and close (or close and open) sequences by faulting the keypad’s tamper switch.

3. Set up “Global features” (if desired). If Anonymous (no security code) System Arming has been enabled in the CSK’s setup, you must enroll this feature in the LYNXR-IE control as follows: a. Program a zone as Zone Type 20 (Arm-Stay) or 21 (Arm-Away) b. When prompted for Input Type, enter 05 (RF button-type transmitter-BR type) c. When prompted for a serial number, transmit two open and close sequences by pressing and releasing the Total Arming button. Repeat to confirm.

4. Set up the Panic feature as follows: a. Program a zone for the applicable 24-hour Zone Type (For detailed definitions of each zone type refer to the LYNXR-IE Installation and Setup Guide.) b. When prompted for Input Type, enter 05 (RF button-type transmitter-BR type) c. When prompted for a serial number, transmit two open and close sequences by pressing and releasing the PANIC button. Repeat to confirm.

5. Set up the keypad Anti-Fraud Blocking feature as follows: a. Program a zone for the applicable Zone Type (For detailed definitions of each zone type.) b. When prompted for Input Type, enter 05 (RF button-type transmitter-BR type). c. When prompted for a serial number, press a random key 21 times to activate the keypad Anti-Fraud

Blocking. Press the “*” key to confirm, OR

Manually copy the serial number entered during Anonymous System Arming or Panic Enrollment above, and manually enter loop 2.

You must wait 5 minutes for the keypad tamper state to be cleared out of the CSK.

6. Set up Relays (if desired). The CSK can control up to eight relays. These can be used to trigger any panel-supported behavior (e.g. X10 events). a. Program each of the ”relay on” and “relay off” sequences as separate zones, using Zone Type 23 and

Input Type 5 “BR” (RF button-type transmitter). b. When prompted for a serial number, activate the desired relay command on the CSK (refer to the

CSK800HF Installation Instructions).

When enrolling an “On” function, Loop 1 will be indicated. When enrolling an “Off” function, Loop 2 will be indicated.

c. In Output Programming, program one output function to “close” a relay on a fault of the “activated

By” zone. d. Program another output function to “turn off” the same relay on a fault of the “activated By” zone.

7. Set up Users. Enroll any of the four principal user-specific functions (arm total, disarm, arm partial) corresponding to each user that was enabled while programming the CSK. Each “user” transmits as a different serial number. The CSK supports the full range of ten users, four functions per user. Each function is enrolled as a zone with the appropriate zone type (e.g. Arm Away), and Input Type 05.

- 40 -

LYNXR-IE Installation and Setup Guide

Enrolling the CSK800HF Monodirectional Keypad

The following example is provided:

Example: Setting up the CSK with two users. User 0 is assigned code 1234 and will be allowed to armaway, arm-stay or disarm the system. User 1 is assigned code 5678 and will be allowed to arm-away or disarm only. It should be noted that these User numbers do not correspond with the LYNR-IE User

Numbers.

Enroll user 0 “total arming” (arm away) function: a. Program a zone as Zone Type 21 (Arm AWAY) b. When prompted, enter Input Type 05 (RF button-type transmitter-BR type). c. When prompted for a serial number, press (ARM-ALL) followed by 1234 on the CSK. Repeat to confirm.

Enroll user 0 “partial arming” (arm stay) function: a. Program a zone as Zone Type 20 (Arm STAY) b. When prompted, enter Input Type 05 (RF button-type transmitter-BR type). c. When prompted for a serial number, press (ARM- PART) followed by 1234 on the CSK. Repeat to confirm.

Enroll user 0 “disarm” function: a. Program a zone as Zone Type 22 (Disarm) b. When prompted, enter Input Type 05 (RF button-type transmitter-BR type). c. When prompted for a serial number, enter 1234 on the CSK. Repeat to confirm.

Enroll user 1 “total arming” (arm away) function: a. Program a zone as Zone Type 21 (Arm AWAY) b. When prompted, enter Input Type 05 (RF button-type transmitter-BR type). c. When prompted for a serial number, press (ARM-ALL) followed by 5678 on the CSK. Repeat to confirm.

Enroll user 1 “disarm” function: a. Program a zone as Zone Type 22 (Disarm) b. When prompted, enter Input Type 05 (RF button-type transmitter-BR type). c. When prompted for a serial number, enter 5678 on the CSK. Repeat to confirm.

Prox (MFID) tags are associated with a particular user during the CSK setup and no additional enrollment is required. When a user brings the prox tag up to the reader it is recognized by the panel as if the user had entered his/her security code at the keypad.

- 41 -

LYNXR-IE Installation and Setup Guide

Voice Prompt Programming

The LYNXR-IE features a quick programming mode that allows you to program the system by responding to a series of voice prompts. The Voice Prompt Programming Guide provides you with the information required to use this feature.

Voice Prompt Programming Keypad Functions:

The keys shown below are used to navigate through the Voice Prompt Programming Feature.

1.

ESCAPE/ OFF

key: Used at any time to exit the current menu and return to the previous prompt.

1

2.

ADD/ AWAY key: Used to add sensors, or keys or save data when entering phone or account numbers.

2

ARMED READY

5

3.

DELETE/ STAY key: Used to delete a sensor when in the delete

Sensors Menu.

4.

SELECT/ AUX key: Used to confirm a selection.

3

OFF

ESCAPE

AWAY

ADD

STAY

DELETE

AUX

SELECT

1

RECORD

4

LIGHTS ON

2

VOLUME

5

TEST

3

PLAY

6

BYPASS

7

LIGHTS OFF

*

STATUS

8

CODE

9

CHIME

0 #

NO DELAY FUNCTION

6

7

4

5.

3 key: Used to scroll forward through menu choices.

01009-021-V1

6.

6 ↓ key: Used to scroll backward through menu choices.

7.

FUNCTION/ #

key:

Used to repeat a voice prompt. (This function cannot be used while entering phone or account numbers.)

Notes: (1) Keying in any new command will terminate the active voice prompt.

(2) If an irrelevant command is entered LYNXR-IE will generate a long rejection beep and repeat the previous voice prompt.

(3) Phone numbers and account numbers can be left blank by pressing the

“ADD/ AWAY ” key without entering any data.

(4) LYNXR-IE automatically saves phone and account number data once all available digits are entered.

ENTERING VOICE PROMPT PROGRAMMING

1. Power-up the control and enter the Installer Code

(4 1 1 2) + 8 8 8.

5. Follow the directions provided by each voice prompt to make your selections.

2. Once you have entered into the Voice Prompt Programming

Mode the system will announce, “Programming, use

ARROWS to scroll choices, press SELECT to accept, press

ESCAPE to quit.”

3. Press

6 ↓ or

3 keys to scroll through the voice menu and follow the instructions provided.

The

FUNCTION/ # key can be used to repeat a voice prompt, as required.

6. When you have completed each programming procedure the system will return to the Main Programming Menu.

4. The system will announce the following options:

“First Central Station Phone Number”

“First Central Station account Number”

“Second Central Station Phone Number”

“Second Central Station account Number”

“Templates”

EXITING VOICE PROMPT PROGRAMMING

1. Once you have returned to the Main Programming Menu, the system will announce, “Programming use ARROWS to scroll choices, press SELECT to accept, press ESCAPE to quit”.

2. Press

ESCAPE/ OFF

to exit Voice Prompt programming mode once you have returned to the Main Programming

Menu.

- 42 -

LYNXR-IE Installation and Setup Guide

Voice Prompt Programming

Enter Voice Prompt Programming Mode: (Installer Code + 8 8 8). Follow the voice prompts to advance to the selected item in the Main Programming Menu.

Add Sensors

First Central Station Phone Number

Delete Sensors

First Central Station account Number

Second Central Station Phone Number Second Central Station account Number

Templates Expert Programming Mode

Program each option as shown below. Use the

6 ↓ and

3 keys to scroll through the voice menu and follow the voice prompts to program the LYNXR-IE.

The CSK800HF Monodirectional Keypad cannot be enrolled using the Voice Prompt Programming mode.

!

To Add a Door Sensor

Select

"Add Sensors"

The LYNXR-IE will enroll a sensor once the transmitter has been activated two times. The system will confirm the enrollment following each subsequent activation of the same transmitter.

Select

"Delay Door"

Select delay door location

See (1)

Activate transmitter twice

System announces descriptors for the programmed sensor

Press

[SELECT]

Press

[SELECT]

Press

[SELECT]

Press

[ADD]

(1) Delay Door Location

Front Basement

Back Sliding

Side Hall

Garage Kitchen

Patio

To add a Window, Motion Detector, or Fire Detection Sensor

Select

"Add Sensors"

Select sensor type

See (2)

Select sensor location

See (3)

To add modifier

Select location modifier

See (4)

Activate transmitter twice

System announces descriptors for the programmed sensor

Press

[SELECT]

Press

[SELECT]

Press

[SELECT]

Press

[SELECT]

Press

[SELECT]

Press

[ADD]

OR

To enroll transmitter

Activate transmitter twice

Press

[ADD]

System announces descriptors for the programmed sensor

(2) Sensor Type (3) Sensor Location (4) Location Modifiers

Window Living

Motion Detector

Fire Detection

Dining room

Bedroom

Family Room

Guest Room

Upstairs

Downstairs

First

Bathroom Laundry Room Second

Nursery Utility

Kitchen Garage

Hall Attic

Basement Office

Front

Rear

Master Bedroom Upstairs Side

- 43 -

LYNXR-IE Installation and Setup Guide

Voice Prompt Programming

To Delete Sensors

Select

"Delete Sensors"

Select

Sensor to be Deleted

Press

[SELECT]

Press

[DELETE]

To Add an Emergency Pendant

Select

"Emergency"

Select pendant type

See (5)

Activate transmitter twice

System announces descriptors for the programmed pendant

Press

[SELECT]

Press

[SELECT]

Press

[ADD]

(5) Pendant Type

Medical

Fire

Silent Police

Police

!

When adding wireless keys, wait 5 seconds between transmissions.

To Add a Wireless Key

Select

"Keys"

Activate transmitter twice

System announces the key number

Press

[SELECT]

Press

[ADD]

LYNXR-IE automatically saves phone and account number data once all available digits are entered.

To Add First Central Station Phone Number

Select

"First Central

Station Phone

Number"

Enter first central station phone number

(up to 20 digits)

Enter first central station account number

(up to 4 digits)

Press

[SELECT]

Press

[ADD]

Press

[ADD]

!

All four digits of the Central Station account number must be entered. If ten-digit format is selected, all

ten digits must be entered.

To Add First Central Station Account Number

Select

"First Central

Station Account

Number"

Enter first central station account number

(up to 4 or 10 digits)

Press

[SELECT]

Press

[ADD]

- 44 -

LYNXR-IE Installation and Setup Guide

Voice Prompt Programming

!

All four digits of the Central Station account number must be entered. If ten-digit format is selected, all

ten digits must be entered.

To Add Second Central Station Phone Number

Select

"Second Central

Station Phone

Number"

Enter second central station phone number

(up to 24 digits)

Enter second central station account number

(up to 4 digits)

Press

[SELECT]

Press

[ADD]

Press

[ADD]

To Add Second Central Station Account Number

Select

"Second Central

Station Account

Number"

Enter second central station account number

(up to 4 or 10 digits)

Press

[SELECT]

Press

[ADD]

Refer to the LYNXR-IE Programming Default Tables to view the complete set of Template (default table) selections.

To Program a Template (Default Table)

Select

"Templates"

Select template

See (6)

Press

[SELECT]

Press

[SELECT]

(6) Template selections

Template 1

Template 2

Template 3

Template 4

To Enter Expert Programming Mode

!

Once you have entered the Expert Programming Mode, the [ESCAPE] key can be used to return to the

Voice Prompt Programming mode.

Select

"Expert programming mode"

Press

[SELECT]

System switches to Expert

Programming Mode

(Refer to the LYNXR-i

Installation and Setup Guide or the LYNXR-i

Programming Guide for additional programming instructions)

- 45 -

LYNXR-IE Installation and Setup Guide

Remote Programming/Control (Downloading)

General Information

The control panel can be remotely programmed from an IBM-compatible Personal Computer (PC), a HAYES

Modem, and ADEMCO’s Compass Downloader for Windows (as specified below).

Multiple security levels protect remote programming against compromise by attempts to defeat the system.

1. Security Code Handshake: An 8-digit download ID code must be matched between the Control and downloader.

2. Site-Initiated Remote Programming: The installer or subscriber initiates the call from the subscriber premises (by entering Installer Code + # + 1) while disarmed. All parameters can then be downloaded via the phone lines using a personal computer.

3. Station-Initiated Remote Programming: The operator calls the site from your office to initiate the download call. The Control hangs up and then calls back the PC via the preprogrammed telephone number. The unit can then be uploaded, downloaded, or controlled from your office.

4. Telco Handoff: The installer or subscriber performs a download session on the call initiated from the site or from local laptop computer (by entering Installer or Master Code + # + 1 at the control panel).

5. Data Encryption: Data passed between the PC and the Control is encrypted for security so that it is very difficult for a foreign device tapped into the phone line to take over communication and substitute system-compromising information.

Equipment required to download to a system at the premises

• An IBM PC compatible computer and appropriate interconnecting cables.

Either a HAYES brand SMARTMODEM 1200 (Level 1.2 or higher external or Level 1.1 or higher [with 4 position DIP switch] internal style), a HAYES brand Optima 336 external, a HAYES brand Optima 24

Plus FAX96, or an ADEMCO CIA Modem.

• Compass Downloader for Windows (at revision level supporting LYNXR-I).

Initial Download: Enter Installer Code + # + 5. This sets field ✻ 95 to 4 rings, and system to “no call-back” option. The download computer can then call the subscriber, make connection, and download all programming data.

Flexible Callback: If enabled in field

93, the download operator can temporarily change the last 1, 2, or 3 digits (depending on selection) of the call back number. This allows the control to call back a computer other than the one programmed, which may be helpful at times of high computer traffic. See field

93 for a full description.

Remote Programming Information

If using Remote Programming, the LYNXR-IE must be connected to the telephone line or to the Internet, as applicable.

The downloading system can perform many functions when in communication with the Control. Besides uploading and downloading, the status of the system can be observed and various commands can be initiated, as follows:

• Arm the system in the away mode; disarm the system.

• Bypass a zone.

• Force the system to accept a new program download.

• Shut down communication functions (for nonpayment of monitoring fees in an owned system).

• Shut down all security system functions (for nonpayment for a leased system).

• Inhibit local keypad programming (prevents account takeover).

- 46 -

LYNXR-IE Installation and Setup Guide

Remote Programming/Control (Downloading)

• Command the system to upload a copy of its resident program to the office.

• Set the time

• View/Modify

• X10/ Scheduling

• Read: arming status, AC power status, lists of faulted zones, bypassed zones, zones currently in alarm, zones currently in trouble, and RF sensors with low battery conditions; read control’s time.

Notes: (1) After the control and the PC have established valid communication, the keypad will become inactive and will display “CC.

(2) The keypad will become active after the download communication is terminated.

(3) The detailed operation of the download functions is covered in the installation instructions for the Compass Downloader for

Windows.

Remote Programming Advisory Notes

• Keypad entries are ignored during the time interval stated above.

• A copy of the program downloaded may be printed using the IBM PC-compatible computer’s internal report generator, when an optional printer is connected (consult your PC manual for proper printer and connections).

• Program upload or download time is approximately one minute, fifteen seconds for a complete program.

- 47 -

LYNXR-IE Installation and Setup Guide

System Operation

Security Codes

Installer Code

The installer programs the 4-digit Installer Code initially as part of the programming procedure. The factory default Installer Code is 4-1-1-2, but may be changed in field

20.

The Installer Code is the only code that can enter Programming mode and also, in normal operation mode, is used to enter the Master Code, which allows access to the normal functions of the system.

Master Code

In normal operation mode, the Installer Code is used to enter the 4-digit Master Security Code.

To enter/change the Master code by installer, using the keypad enter:

Installer Code + [CODE key] + [02] + desired 4-digit Master Code

To change the Master code by master, using the keypad enter:

Current Master Code + [CODE key] + [02] + new Master Code + new Master Code again

Secondary User Codes

In normal operation mode, the Master Security Code can be used to assign up to 6 secondary 4-digit security codes, including a Babysitter Code and a Duress Code. The Master Code can also be used to remove secondary codes from the system (individually).

To assign (or change) a secondary security code, using the keypad enter:

Master Code + [CODE key] + User # (03–08) + desired Secondary Code

The system will emit a single beep when each secondary code has been successfully entered.

To delete a secondary security code, using the keypad enter:

Master Code + [CODE key] + User # (03–08)

Security Code Notes

• The Master and Secondary security codes permit access to the system for arming, disarming, etc.

• The Installer Code can disarm the system only if it was used to arm it.

• The Babysitter Code (User Code No. 7) can disarm the system only if it was used to arm it.

• Duress code (User Code No. 8) sends a special code to the monitoring station when used to perform any system operation. Instruct users to be careful not to use this code for normal usage.

• If a secondary code is inadvertently repeated for different users, the lower user number will take priority.

• Opening/closing reports are sent for the Installer Code as No. 01, with the appropriate subscriber number. Master

Code and set of secondary user codes are sent as Nos. 02 and 03–08, respectively, in Contact ID® format (with the appropriate user number).

Panic Keys

There are three panic key pairs that, if programmed, can be used to manually initiate alarms and send a report to the central station.

Each can be individually programmed for 24-hour silent, audible, personal or fire emergency responses. The panic function is activated when both keys of the appropriate key pair are pressed at the same time.

The panic functions are identified by the system as follows:

Keys

[1] & [

] 95

[

] & [#]

Displayed as Zone

99

Important: For the silent panic functions to be of practical value, the system must be connected to a central station.

[3] & [#] 96

- 48 -

LYNXR-IE Installation and Setup Guide

System Operation

Display

The LCD Display is only active for a period of 35 seconds after a valid User Code has been entered or the

Status Key [

] has been pressed. The display is also active during the Entry or Exit Delay period and when the system is in an interactive mode (i.e.; Time/Date, Scheduler, Speaker Phone, Installer Programming).

The display will also be active if there is an active alarm in the system. When the system is disarmed the

READY LED will be lit.

Keypad Functions

The keypad allows the user to arm and disarm the system, and perform other system functions, such as bypassing zones. Zone and system conditions (alarm, trouble, bypass) are displayed in the display window.

When an alarm occurs, keypad sounding and external sounding will occur, and the zone(s) in alarm will be displayed on the keypad. Pressing any key will silence the keypad sounder for 10 seconds (only once).

Disarming the system will silence both keypad and external sounders. When the system is disarmed, any zones that were in an alarm condition during the armed period will be displayed (memory of alarm). To clear this display, simply repeat the disarm sequence (enter the security code and press the OFF key). The keypad also features chime annunciation, and 3 panic key pairs for silent, audible, fire or personal emergency alarms. These keys can notify the central station of an alarm condition, if that service is connected. A summary of system functions is provided below for more detailed information refer to the

User’s Manual.

The system will not arm when the conditions listed below exist however, re-entering the command within 35 seconds will override the condition and the system will arm.

• AC Loss

• System Low Battery

• RF Jam

• Communications Failure

• Sensor Low Battery (non-fire zones only)

• Entry/Exit Zone Fault

Security Functions

(Empty boxes represent the user’s security code)

Checking system status:

........................

STATUS

(high level messages); press

STATUS again for secondary messages

To arm in STAY mode:

..........................

+

STAY

(or installer code + [3])

To restart exit delay:

...............................

STAY

(applies only if system is armed in Stay mode)

To arm in AWAY mode:

...........................

+

AWAY

(or installer code + [2])

To arm with NO DELAY:

........................

+

AWAY or

STAY

+

NO DELAY

To disarm the system and silence alarms:

+

OFF

To bypass a zone(s):

................................

+

BYPASS

+ 2-digit zone number(s)

To turn Chime mode on or off:

..............

FUNCTION

+

CHIME

Message Center

To record a message: .............................

FUNCTION

+

RECORD

To stop recording before end of 90 seconds:

OFF

To play back a message:........................

FUNCTION

+

PLAY

To skip a message: ................................

[

]

To delete all messages:..........................

FUNCTION

+

DELETE

(during message replay)

Volume Control

To adjust message playback/system announcement volume:

FUNCTION

+

VOLUME

+ [3] or [6]

To mute system announcements:

.........

FUNCTION

+

VOLUME

+

OFF

To restore/unmute announcement & volume:

FUNCTION

+

VOLUME

+ [3] or [6]

- 49 -

LYNXR-IE Installation and Setup Guide

System Operation

Other Functions

To set the time and date:

.......................

+

FUNCTION

+ [63]

To set the scheduling:

.............................

+

FUNCTION

+ [64]

To activate or deactivate X10 devices 1-6:

FUNCTION

+

LIGHTS ON or

LIGHTS OFF

+ device number

To activate or deactivate X10 devices 7 & 8:

+

FUNCTION

+

LIGHTS ON or

LIGHTS OFF

+ dev. No

.

To add a user code:

.................................

*

+

CODE

+ user number + user’s code (*master code)

To delete a user code (except Master Code):

*+

CODE

+ user number (* master code)

To turn Test mode on:

.............................

+

TEST

To turn Test mode off:

.............................

+

OFF

To use the defined AUX function:

Press and hold

AUX key 2 secs (4 beeps) +

To define AUX function:

+

FUNCTION

+

AUX

+ action separated by +

AUX terminated by +

AUX

+

AUX

To send message to “Follow Me” phone:

Press and hold

AUX key 2 seconds (4 beeps)

To program Follow Me Announcement telephone number

:

+

FUNCTION

+ [65]

Speaker Phone Operation

To place a call or answer a call using the speaker phone:

[#] +

AUX

To flash (switch between two calls using call waiting):

AUX

NOTE

The ARMED and READY LEDs blink alternately when the Speaker Phone is

Active.

To hang up and exit speaker phone mode:

OFF

To enable/disable (toggle) ringer:

[#] +

VOLUME

+

AUX

To return the keypad to telephone mode after disarming the system:

[#] +

AUX

Remote Phone Control Feature

The remote phone control feature, which must be enabled in field

91, allows the user to access the security system from any off-site touch-tone telephone. The control will pick up the incoming call, based on the ring count specified in field ✻ 95, and will announce “SYSTEM ENTER CODE” every three (3) seconds for the next eight (8) seconds. During this period the panel will wait for a valid User Code to be entered. If a valid

User Code is not entered or the eight (8) second period expires a modem tone will be generated for remote programming (Compass Downloading). If a valid User Code has been entered, the control will announce the current system status and/or beeping sounds.

Keypad Functions

Remote Phone Control Feature

To remotely disarm system:

+ [1]

To remotely arm in AWAY mode:

+ [2]

To remotely arm in STAY mode:

+ [3]

To remotely arm in AWAY or STAY with no delay:

+ [2] or [3] + [0]

To remotely activate X10 devices 1-6:

[#] + [4] + device no.

To remotely activate X10 devices 7 & 8:

+ [#] + [4] + device no.

To remotely deactivate X10 devices 1-6:

[#] + [7] + device no.

To remotely deactivate X10 devices 7 & 8:

+ [#] + [7] + device no.

To remotely Bypass zones:

+ [6] + zone no.

To remotely activate Forced Bypass:

+ [6] + [#]

To remotely check system status:

[✻]

To end remote phone control session:

Hang Up or enter

+ [9]

- 50 -

LYNXR-IE Installation and Setup Guide

System Operation

Audio Alarm Verification (Two-Way Voice Feature)

This feature allows the central station operator to listen, talk to or conduct a two-way conversation with an individual(s) at the premises. It also assists the operator in gathering information about the nature and location of the alarm that may be helpful in responding to police and fire departments. All LYNXR-IE control panels are capable of supporting the Two-Way Voice feature. The LYNXR-IE does not make system announcements when the Two-Way voice feature is active.

Activation

The LYNXR-IE sends the “alarm message” followed by a “Listen-in-to-Follow message” (Contact ID® code

606) to the Central Station. The Listen-in-to-Follow message causes the Central Station’s digital receiver to temporarily hold the phone line for approximately 1-minute. When the LYNXR-IE receives the “kissoff” from the central station, indicating that the alarm message has been received, the Two-Way Voice (AVM) feature is activated in the (default) “Listen Mode” and sirens and keypad sounds are discontinued. The

LYNXR-IE transmits a beep acknowledgment to the Central Station, once per second. The beep alternates between two tones and indicates that the LYNXR-IE is waiting for a session command from the Central

Station operator. Once a command is issued the beep acknowledgement is discontinued, however, if a command is not issued within two minutes the system will “time out” and the call will be terminated.

Operator Commands

The Central Station operator begins the session, which last 5 minutes, by entering one of the valid AVM commands shown in the table below. The session may be extended 5 minutes, without changing the operating mode, by pressing the [7] key on the touch-tone phone. Selecting another operating mode also resets the session an additional 5 minutes. During the last minute of the 5 minute, session, the LYNXR-IE generates two beeps every 30 seconds to alert the Central Station operator that the session is about to time out. The Central Station operator may then extend the session by pressing the [7] key on the touch-tone phone. If the session is not extended the phone line is disconnected, and the session is ended. Sessions may be ended at any time by pressing the [9] key on the touch-tone phone. The AVM modes are described as follows:

Note: When entering AVM commands make sure the Central Station receiver has been disconnected from the phone line, otherwise AVM commands may not go through.

Key

1

2

3

Function

Talk Mode: Pressing the [1] key on the touch tone phone, enables one-way voice communication from the central station to the violated premises, and allows the operator to talk communicate through the LYNXR-IE speaker. In this mode the

ARMED (red) and READY (green) LEDs blink alternately.

VOX (Voice) Mode: Pressing the [2] key on the touch-tone phone, enables two-way voice communications between the central station and the violated premises. In this mode the ARMED (red) and READY (green) LEDs blink alternately.

Listen Mode: Pressing the [3] key on the touch-tone phone, enables one-way audio from the violated premises to the central station. The Listen Mode is the start up default mode of the voice feature and allows the operator to listen through the

LYNXR-IE microphone. This mode does not affect the existing LED pattern.

7

9

Extends the session 5 minutes without changing its operating mode.

Ends the session and disconnects the phone line.

- 51 -

LYNXR-IE Installation and Setup Guide

System Operation

“Follow Me” Reminder Feature

This feature allows the user to schedule a time driven message. When activated the system will dial a phone number, that the installer programs in Field ✻ 46, and deliver a voice message (custom words 72, 73, and 74).

The LYNXR-IE will immediately begin transmitting the voice message and will repeat the message for 45 seconds. Pressing any touch-tone key on the answering phone will acknowledge the message ending the session and preventing the system from redialing the programmed number. Delivery of a reminder message on the local LYNXR-IE keypad will continue. If the message has timed out the system will redial the programmed number a maximum of seven additional times or until it is acknowledged. Pressing any key on the LYNXR-IE keypad will terminate (acknowledge) both the follow me reminder and the local reminder announcements.

Notes: (1) This feature is only supported if programmed in field ✻49.

(2) The follow me reminder will be terminated if any other event requires the system to dial out, or if an audible alarm has occurred, however, delivery of the local schedule reminder message will continue.

“Follow Me” System Announcement Feature

This feature allows the LYNXR-IE to deliver a voice system message to the secondary phone number programmed by the installer. The LYNXR-IE will first transmit reports to the Central Station and after receiving its kiss-off the system will dial the secondary phone number and begin transmitting the voice message. This message is a repeatable system status announcement. Like the Follow Me reminder, pressing any key on the answering telephone or the local LYNXR-IE keypad will terminate (acknowledge) the message. The system will dial the secondary phone number a maximum of eight times. The Follow Me alarm functions may be triggered by a variety of events depending upon the selections made during programming in field ✻ 49.

Note: The follow me system announcement will be terminated if any other event requires the system to dial out or if an audible alarm has occurred.

Powerline Carrier Devices (e.g. X10 devices)

If Powerline Carrier Devices are used, two keypad entries available to the user are included. They can manually activate or deactivate the device(s) for starting or stopping some action, such as turning lights on or off, etc.

These keypad entries are:

Security Code* + [#] + [4] + Device # activates (starts) that device.

Security Code* + [#] + [7] + Device # de-activates (stops) that device.

*Code is required for devices 7 and 8. Code is not required for devices 1-6.

Exit Error Alarm Displays

The system will display the following if programmed in Field *59.

Display Meaning

CA will appear along with a zone indication if an exit or interior zone contained a fault during closing at the time the exit delay ended (e.g., exit door left open),

but the system was disarmed during the entry delay time. The alarm

EA sounder and keypad sound continuously, but stop when the system is disarmed.

No message will be transmitted to the central station.

will appear along with a zone indication if an exit or interior zone contained a fault during closing at the time the exit delay ended, but the system was NOT

disarmed during the entry delay time. The alarm sounder and keypad sound continuously until the system is disarmed (or timeout occurs). An Exit

Alarm message is sent to the central station. OR if an alarm from an exit or interior zone occurs within two minutes after the end of an exit delay

Entering a second OFF sequence (Code +

OFF

) will clear the display.

- 52 -

LYNXR-IE Installation and Setup Guide

System Operation

System Displays

Display Meaning

PC

PH

AC

Remote Phone Control feature is active (Appears in place of the clock).

System Speaker Phone mode is active (Appears in place of the clock).

AC power is present. If not displayed, the system is operating on backup battery power.

ALARM

System is armed and an intrusion has been detected (also appears during a fire alarm or audible emergency alarm). Accompanied by the protection zone that is in alarm.

AWAY

BYPASS

CHIME

FAULT

All burglary zones, interior and perimeter, are armed.

One or more burglary protection zones have been bypassed.

Chime feature is activate

A malfunction is discovered in the system; or an open is detected in a fire zone; or a fault in a day/night burglary zone is discovered during a disarmed period.

Accompanied by a display of the zone number in trouble.

FIRE

A fire alarm or fire fault is present. Accompanied by a display of the zone that is in alarm

LOW BAT

Low battery condition in a wireless sensor (if zone number is displayed) or low system battery (if no zone number is displayed). If 00 is displayed, a wireless keypad has a low battery condition.

INSTANT

MESSAGE

REC

STAY

TEST

Entry delay is turned off.

A message has been recorded and has not yet been played back.

The system is in Recording mode.

Perimeter Burglary zones, such as protected windows and doors, are armed

System is in Test mode.

- 53 -

LYNXR-IE Installation and Setup Guide

Testing the System

Test Mode

After installation is completed, the security system should be carefully tested, as follows.

1. With the system in the disarmed state, check that all zones are intact. If the READY LED is not lit, press the [

] key to display the faulted zone(s). Restore faulted zone(s), if necessary, so that the

READY LED lights. Fault and restore every sensor individually to assure that it is being monitored by the system. the LED segments on the keypad display light for 3 seconds. LYNXR-IE announces the zone’s voice descriptor (if programmed) followed by 3 beeps, each time a contact is faulted. A test report should be transmitted (if programmed) to the central station immediately. If the backup battery is discharged or missing, the sounder may not turn on and a LOW BATTERY report will be transmitted with a TEST report. The keypad will beep once every 45 seconds as a reminder that the system is in the Test mode.

3. To turn off the Test mode enter security code and press the OFF key.

Notes: (1) Triggering a zone set to Arm AWAY, Arm STAY, or Disarm will take the system out of Test and cause that action.

(2) BR type transmitters do not display during Test mode (keypad beeps only)

(3) Macros cannot be run from the Test mode.

(4) Test mode automatically ends after 4 hours.

Armed System Test

Alarm messages will be sent to the central station during the following tests 1 and 2. Notify them in advance that tests will be in progress.

1. Arm the system and fault one or more zones. After 15 seconds (if optional dialer delay is selected), silence alarm sounder(s) by entering the code and pressing OFF. Check entry/exit delay zones.

2. Check the keypad-initiated alarms that are in the system by pressing the Panic key pairs. If the system has been programmed for audible emergency, the keypad will emit a steady alarm sound, and

ALARM” and zone number will be displayed. Silence the alarm by entering the security code and pressing OFF.

If the system has been programmed for silent emergency, there will be no audible alarms or displays, but a report will be sent to the central station.

3. If Powerline Carrier Devices have been installed, test their programmed action.

4. Notify the central station when all tests are finished, and verify results with them.

5. To test the wireless part of the system and the RF receiver, perform the two additional tests described in the Installing Wireless Zones section: Sniffer mode and Go/No Go Test.

Note: System Test mode (installer/master code + test) and Go/No Go Test (installer code + # + 8) will be

automatically terminated after 3-1/2 to 4 hours if the installer or user does not manually terminate it. This ensures that fire and panic zones will not remain disabled. However, Sniffer mode (installer code + # + 3) does

not automatically expire. You must manually exit (Installer/User Code + OFF) Sniffer mode to

return to normal operation.

TO THE INSTALLER

Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system.

The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as acquainting the user with the proper operation and limitations of the alarm system and its component parts. Recommendations must be included for a specific program of frequent testing (at least weekly) to ensure the system’s proper operation at all times.

- 54 -

LYNXR-IE Installation and Setup Guide

System Communication

This section provides an explanation of formats this system accommodates for reporting alarms and other system conditions to the central station. The process of a successful transmission consists of both the method of communication between the control panel and the central station receiver, and the actual way the information is sent and displayed at the central station.

Communication Overview

When the panel calls the central station receiver, it waits to hear a “handshake” frequency from the receiver to confirm that the receiver is on-line and ready to receive its message. Once the panel hears the handshake it is programmed to listen for, it sends its message. The panel then waits for a “kissoff” frequency from the

3 receiver acknowledging that the message was received and understood.

If the handshake frequency is not given or is not understood by the panel, the panel will not send its message. Once the handshake frequency is received and understood by the panel, the panel will send its message. If there is an error in the transmission (the receiver does not receive a “valid” message), the kissoff frequency will not be given by the central station receiver.

The panel will make eight attempts to the primary telephone number and eight attempts to the secondary telephone number (if programmed) to get a valid message through. If the panel is not successful after its numerous attempts, the keypad will display “FC.”

The following chart defines the three sets of (handshake/kissoff) frequencies that the panel supports, and the different formats that can be sent for each.

FORMAT

Contact

ID®

HANDSHAKE TRANSMITS DATA KISSOFF

1400–2300Hz DTMF (10 cps) 1400Hz

TRANSMIT TIME

Under 3 seconds

Report Code Formats

ADEMCO Contact ID®

Comprises a 4-digit subscriber number, 1-digit event qualifier

Reporting Format

(“new” or “restore”), 3-digit event code, and 3-digit zone number, user number, or system status number (see the accompanying Contact ID Event Code list).

ADEMCO Contact ID® Reporting takes the following format: CCCC Q EEE GG ZZZ where:

CCCC = Customer (subscriber) ID

Q = Event qualifier, where: E = new event, and R = restore

EEE = Event code (3 hex digits) (for a complete list of event codes, refer to the central office receiver manual)

ZZZ = Zone/Contact ID® number reporting the alarm, or user number for open/close reports. System status messages (AC Loss, Walk Test, etc.) contain zeroes in the ZZZ location.

- 55 -

LYNXR-IE Installation and Setup Guide

System Communication

CONTACT ID® EVENT CODES

Code

121 Duress

122 Alarm, 24-hour Silent

123 Alarm, 24-hour Audible

150

302

Definition

Alarm, 24-Hour Auxiliary

Low System Battery/Battery Test Fail

Code Definition

373 Fire Loop Trouble

374 Exit Error Alarm

380 Global Trouble, Trouble Day/Night

381 RF Supervision Trouble

383 RF Sensor Tamper (Trouble)

384 RF Sensor Low Battery

401 Disarmed, Armed AWAY (NO DELAY),

Armed AWAY

403 Scheduled Auto Arm

406 Cancel User

407 Remote Arm/Disarm (Downloading)

441 Disarmed/Armed STAY/NO DELAY

570 Bypass

344 RF Jam Detected

606 AAV to follow

353

354

ECP Communication/Supervision failure, case tamper or low battery

Failure to Communicate with Central Station

623 Event Log 80% Full

Notes: (1) The following codes are logged in the event log upon occurrence, but are not reported:

305 = System Reset

627 = Keypad Program Mode Entry

655 = Master Code Changed (by Installer)

(2) LRR/IP Communications Module Low Battery and Low Battery restore reports are sent real time. LRR/IP Communications

Module trouble restore report is sent after two code + off (only if physically restored).

(3) Communications failure (CID 354) event is logged when the next report is successfully sent followed by a communications failure restore report.

- 56 -

LYNXR-IE Installation and Setup Guide

Troubleshooting Guide

Trouble Conditions

The word “FAULT” on the keypad’s display, accompanied by a rapid “beeping” at the keypad, indicates that there is a trouble condition in the system. Pressing any key can silence the audible warning sound. Instruct users to call for service immediately upon seeing any of the following messages.

System Trouble Displays

Display Meaning

FAULT

and one or more zone numbers indicates that a problem exists with the displayed zone(s) and requires attention. After correcting the problem, the display can be cleared by entering the security code plus the OFF key twice.

FAULT 103

LOW BAT

LOW BAT

The fault condition may also be caused by some change in the environment that prevents the built-in receiver from receiving signals from a particular wireless sensor.

Indicates one of the following:

• control panel lost communication with the communications module

• communications module tamper detected (cover removed)

• primary communications path failure

• radio is not registered; account not activated

• primary power loss

• secondary communications path failure

• battery charger failure

• low battery

with no zone number indicates that the system’s backup battery is weak. bF

CA

with a zone number and a once-per-45 seconds “beeping” at the keypad indicates that a low battery condition exists in the wireless sensor displayed (zone “00” indicates a wireless button/keypad). If the battery is not replaced within 30 days, a “FAULT” display may occur.

Backup LRR/GSM/IP module communication failure (displayed on RF Keypad only)

CC appears if an exit or interior zone contained a fault during closing at the time the Exit

Delay ended (e.g., exit door left open), but the system was disarmed during the Entry Delay time. The alarm sounder and keypad sound continuously, but stop when the system is disarmed. No message will be transmitted to the central station.

Modem Comm.:

system is communicating with the central station for change of function or status verification. dI

Busy-Standby displayed upon power-up. After approximately 1 minute* the green “READY” LED should light. If the “dI” remains displayed for more than 1 minute, the system is disabled.

*To bypass the 1-minute delay, press [#] + [0].

EA

FC

90

No display

Important: Do not try to bypass 1minute delay before “dI” is displayed! appears when Exit Delay ends if an exit or interior zone contained a fault during closing.

The alarm sounder and keypad sound continuously until the system is disarmed (or timeout occurs). An “Exit Alarm” message is sent to the central station. Also results if an alarm from an exit or interior zone occurs within 2 minutes after the end of an Exit Delay. communication failure has occurred. This message clears only when the system is subsequently armed. system has detected an RF jamming condition or excessive interference.

Power Failure

If there is no keypad display at all, and the LED indicators are not lit, operating power for the system has stopped and the system is inoperative.

If the display is lit and the AC display is off, the system is operating on battery power only.

During an AC power loss, the backlighting will turn off and the indicators will flicker slightly to minimize deep discharge of the battery.

- 57 -

LYNXR-IE Installation and Setup Guide

Troubleshooting Guide

S y s t e m ( i n c l u d i n g W i r e l e s s )

SYMPTOM POSSIBLE CAUSE REMEDY

not received at control. number appears during Transmitter

Sniffer mode, but does not clear. on keypad. message

1a. Transmitter not properly powered. 1a Check or change transmitter’s battery.

1b. Transmitter is located too far from RF receiver.

1b. Move transmitter or RF receiver.

1c. There is metal shielding between transmitter and RF receiver.

1c. Check for large metal obstructions, then relocate transmitter if necessary.

1d. Verify by activating control with another, similar transmitter. If O.K. now, return defective transmitter.

1e. Transmitter No. (zone) is not programmed.

2a. Transmitter zone type (ZT) is set to 00

(Not Used).

2b. Transmitter battery not installed.

2c. Wireless transmitter not “entered” in system.

3a. “Low Bat” (no zone Nos.)

3a. System battery is low or missing.

3b. “Low Bat” + “00”.

3c. “Low Bat” + “nn”.

3b. Remote RF keypad/button battery is low.

3c. Transmitter for zone “nn” has a low battery.

3d. Standard- or High-Capacity battery connected to wrong receptacle.

2a. Set ZT to a valid active zone type in field

✻56.

2b. Install proper battery.

2c. “Enter” unit in field

✻56 or ✻83.

3a. Replace system battery.

3b. Replace battery in the RF keypad.

3c. Replace the battery in the displayed transmitter.

3d. Ensure that battery is properly connected.

4.

5.

Periodic beep(s) from

keypad.

There is no response to a transmitter in normal operation, although zone number clears during

Transmitter Sniffer

mode.

4a. System is in Test mode.

4b. A transmitter low battery has occurred and is displayed.

4c. A supervision fault has occurred.

4d. System low battery

Put control in Test mode. If zone does not respond, try operating the tamper switch or another input to the transmitter.

5a. If another input causes the zone to be displayed, the wrong input was “entered” when programming.

5b. If no response at all from this transmitter, this physical transmitter has not been entered by the system.

Transmitter Sniffer display is being cleared by another unit programmed for this zone.

4a. Enter Code + OFF to exit Test mode.

4b. Enter Code + OFF and replace the battery.

4c. Check the transmitter indicated. Restore communication to the receiver to cancel the condition.

4d. Replace system battery

5a. Delete input’s serial number (not the zone), and enter the proper input (see field

✻56).

5b. Determine which transmitter is programmed for this zone and reprogram as necessary.

6.

7.

Nuisance or phantom alarm.

Intrusion alarm for no apparent reason.

6. Sensors not properly installed, wired, or monitored.

7a. Protected door or window opened while system armed.

7b. Improper user operation of exit/entry delays.

7c. Magnets located too far from switches, and/or doors and windows not properly aligned.

6. Check installation to see if in accordance with established procedure.

7a. Check with all occupants of protected home.

7b. Check setting of entry and exit delays.

7c. Check all openings for proper switch and magnet orientation.

- 58 -

LYNXR-IE Installation and Setup Guide

Troubleshooting Guide

C o n t r o l

SYMPTOM

1. The word “AC” is not displayed. message not being received.

POSSIBLE CAUSE

1a. Interrupted AC power supply.

2a. System in Test mode.

2b. Telephone connection not secure.

2d. Telephone number in program needs prefix or access code.

2e. Telephone call to central monitoring station requires operator assistance.

Open or faulted zone(s)

3. Does not arm properly.

READY light not on.

4. System doesn’t respond to keystrokes on keypad.

4a. System is in communication with downloader at central station.

4b. System has just been powered and is in its one minute initialization.

REMEDY

1a. Check transformer connection and powerline circuit breaker.

2a. Remove from Test mode.

2b. Check all connections.

2c. Check with a different CONTROL

PANEL.

2d. Program prefix or access code into the

CONTROL PANEL.

2e. System cannot work in this situation.

Check for faulted zones and make intact, or use Bypass arming, if desired.

4a. Wait until download session is finished.

4b. Wait for initialization to finish, or bypass this time by pressing ‘#’ + ‘0.’

Smoke Detectors

SYMPTOM

1. Detector alarms, no apparent reason.

POSSIBLE CAUSE

1a. Dust, dirt in sensing chamber.

REMEDY

1a. Clean unit’s sensing chamber with vacuum cleaner per unit’s instructions.

1b. See unit’s instructions for locations to avoid.

Relocate as necessary.

2a. Check for proper installation of battery.

Try new battery.

- 59 -

LYNXR-IE Installation and Setup Guide

Programming Default Tables

Function

*25 Powerline carrier device house code

*28 Power Line Frequency/Real Time Clock Time Base

*29 Daylight saving time start/end month

*30 Daylight saving time start/end weekend

*31 Single alarm sounding per zone

*35 Entry delay 1 (zone type 01)

*36 Entry delay 2 (zone type 02)

*37 Audible exit warning/quick exit

*38 Confirmation of arming ding

*39 Power up in previous state

*43 Primary subscriber account number

*44 Secondary subscriber account number

*46 “Follow Me Reminder” Phone Number

*50 15 second dialer delay (burglary)

*51 Periodic test report

*52 First test report offset

*54 Lack of usage notification

*56 Enhanced Zone programming

*59 Exit error report code

*61 Bypass report code

*62 AC loss report code

*63 Low battery Report code

*66 Arm away/stay report code

*67 RF transmitter low battery report code

*70 codes

*71 Trouble restore report code

*72 Bypass restore report code

*73 AC restore report code

*74 Low battery restore report code

*75 RF transmitter low battery restore report code

*76 Test restore report code

*78 Programmable Time Generation Time

*80 Powerline Carrier Devices

*81 Zone lists for devices

*84 Assign zone voice descriptors

*87 Auxiliary Function/ Manual Message

*89 Event log 80% full report code

(boldface indicates defaults that differ between tables)

Table 1 Table 2 Table 3 Table 4

4112 4112 4112 4112

0 0 0 0

0 0 0 0

0 0 0 0

0 0 0 0

1 1 1 1

1

3,11

2,1

0

1

3,11

2,1

0

1

3,11

2,1

0

1

3,11

2,1

0

0 0 0 0

1 1 1 1

7,0 6,0 7,0 7,0

3,0 4,5 3,0 3,0

6,0

1,1

0

1

6,0

0,1

0

1

6,0

1,1

0

1

6,0

1,1

0

1

--- --- --- ---

--- --- --- ---

--- --- --- ---

15,15,15,15

---

15,15,15,15

---

15,15,15,15

---

15,15,15,15

---

--- --- --- ---

5 5 5 5

1,1 1,1 1,1 1,1

0 0 0 0

0

0

1

3

0

0

0

0

2

0

2

0

2

0

2

0

See *56 table See *56 table See *56 table See *56 table

0 0 0 0

1 0 1 1

1,0 1,0 1,0 1,0

0,0

0,0

0,0

0,0

0,0

0,0

0,0

0,0

1,0 1,0 1,0 1,0

1,0 1,0 1,0 1,0

0 0 0 0

0,0 0,0 0,0 0,0

1,0 1,0 1,0 1,0

1,0 1,0 1,0 1,0

1 1 1 1

1,0 1,0 1,0 1,0

0,0

0,0

1,0

1,0

0,0

0,0

1,0

1,0

0,0

0,0

1,0

1,0

0,0

0,0

1,0

1,0

0,0

0,0

1,0

0,0

0,0

0,0

0,0

0,0

See *80 table See *80 table --- See *80 table

See *81 table See *81 table See *81 table See *81 table

0,0 0,0 0,0 0,0

Refer to *84 Programming

0

0,0

1

0,0

0

0,0

1

0,0

- 60 -

LYNXR-IE Installation and Setup Guide

Programming Default Tables

(boldface indicates defaults that differ between tables)

Function

*90 Event logging

*91 Alarm audio verification/remote phone control

*92 Number of reports in armed period

*93 Flexible call back

*94 Download phone number

*95 Ring detect count for downloading/remote phone control

Default Master Code

Default Duress Code

By activating *96, Field 43, and 44 will be changed to 15, 15, 15, 15.

Table 1

15

2

1

Table 2

15

2

1

Table 3

15

2

1

Table 4

15

2

1

0

---

15

1,2,3,4

0

---

15

1,2,3,4

0

---

15

1,2,3,4

0

---

15

1,2,3,4

--- --- --- ---

56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 1

Zone No. Zone Type Alarm Code Input Type Loop Number Zone Descriptor

2 01 1,0 3 (RF) 2 47, 04 (FRONT DOOR)

3

4

01

03

1,0

1,0

3 (RF)

3 (RF)

2

2

33, 04 (BACK DOOR)

80 (WINDOW)

5 10 1,0 3 (RF)

26 21 1,0 5

1 56 (MOTION DETECTOR)

3

27 22 1,0 5

28 20 1,0 5

29 23 0,0 5

30 21 1,0 5

2

4

1

3

31 22 1,0 5 2

32 20 1,0 5 4

33 23 0,0 5 1

92 --- 1,0 --- ---

94 --- 1,0 ---

97 --- 1,0 ---

---

---

99 06 1,0 --- ---

NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 94 is Phone Line Monitor, Zone 97 is Case

Tamper; Zone 99 is keypad panic

56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 2

Zone No. Zone Type Alarm Code Input Type Loop Number Zone Descriptor

2

3

4

5

01

01

01

04

1,0

1,0

1,0

1,0

3 (RF)

3 (RF)

3 (RF)

3 (RF)

2

2

2

1

6 09 1,0 3 (RF) 1

26 21 1,0 5 3

27 22 1,0 5 2

28 20 1,0 5 4

29 23 0,0 5 1

30 21 1,0 5 3

31 22 1,0 5 2

32 20 1,0 5 4

33 23 0,0 5 1

92 --- 1,0 --- ---

47, 04 (FRONT DOOR)

33, 04 (BACK DOOR)

48, 04 (GARAGE DOOR))

56 (MOTION DETECTOR)

22, 02 (SMOKE DETECTOR)

94 --- 1,0 ---

95 08 1,0 ---

96 09 1,0 ---

97 --- 1,0 ---

---

---

---

---

99 07 1,0 --- ---

NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 92 is Duress; Zone 94 is Phone Line Monitor;

Zones 95, 96 and 99 are keypad panics

- 61 -

LYNXR-IE Installation and Setup Guide

Programming Default Tables

56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLES 3 & 4

Zone No. Zone Type Alarm Code Input Type Loop Number Zone Descriptor

2

3

4

5

6

7

8

9

01

01

03

03

03

03

10

09

1,0

1,0

1,0

1,0

1,0

1,0

1,0

1,0

3 (RF)

3 (RF)

3 (RF)

3 (RF)

3 (RF)

3 (RF)

3 (RF)

3 (RF)

26 21 1,0 5

27 22 1,0 5

28 23 0,0 5

29 23 0,0 5

30 21 1,0 5

31 22 1,0 5

32 23 0,0 5

33 23 0,0 5

92 --- 1,0 ---

2

2

2

2

2

2

1

1

3

2

4

1

3

2

4

1

---

47, 04 (FRONT DOOR)

33, 04 (BACK DOOR)

80 (WINDOW)

80 (WINDOW)

80 (WINDOW)

80 (WINDOW)

56 (MOTION DETECTOR)

22, 02 (SMOKE DETECTOR)

94 --- 1,0 ---

97 --- 1,0 ---

99 06 1,0 ---

---

---

---

NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 92 is Duress; Zone 94 is Phone Line Monitor;

Zone 99 is keypad panic

80 DEFAULT TABLE: APPLIES TO DEFAULT TABLE 4 (devices 2-7 have no default values)

Start Stop

Device Number action Event Zone List

Zone Type

System Operation

Restore of

Zone List

Zone type

System operation

2 2

8** 2 33 36

** NOTE: If using an X10 Powerhouse Security SH10A siren as device 8, you must change the device action default to “3” if using default table 4.

80 DEFAULT TABLE: APPLIES TO DEFAULT TABLE 1 and 2 (devices 1-7 have no default values)

Start Stop

Device Number action Event

8** 2

Zone List

Zone Type

System Operation

Restore of

Zone List

33

Zone type

System operation

36

81 ZONE LIST FOR OUTPUT DEVICES DEFAULT TABLE: Applies To Default Table 1 - 4.

Zone List 1 28, 32

Zone List 2 29, 33

Zone List 3 2, 3

- 62 -

LYNXR-IE Installation and Setup Guide

WARNING

THE LIMITATIONS OF THIS ALARM SYSTEM

While this System is an advanced design security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example:

• Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device.

• Intrusion detectors (e.g., passive infrared detectors), smoke detectors, and many other sensing devices will not work without power. Battery-operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly.

• Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path.

• A user may not be able to reach a panic or emergency button quickly enough.

• While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the

Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second floor detector, for example, may not sense a first floor or basement fire. Finally, smoke detectors have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending on the nature of the fire and/or location of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death.

• Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows.

Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of the protected area approaches the temperature range of 90° to 105°F (32° to 40°C), the detection performance can decrease.

• Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices are located on a different level of the residence from the bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear the warning if the alarm is muffled by noise from a stereo, radio, air conditioner or other appliance, or by passing traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people.

• Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.

• Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately.

• This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to last as long as 10 years, the electronic components could fail at any time.

The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This alarm system should be tested weekly to make sure all sensors and transmitters are working properly. The security keypad

(and remote keypad) should be tested as well.

Wireless transmitters (used in some systems) are designed to provide long battery life under normal operating conditions.

Longevity of batteries may be as much as 4 to 7 years, depending on the environment, usage, and the specific wireless device being used. External factors such as humidity, high or low temperatures, as well as large swings in temperature, may all reduce the actual battery life in a given installation. This wireless system, however, can identify a true low battery situation, thus allowing time to arrange a change of battery to maintain protection for that given point within the system.

Installing an alarm system may make the owner eligible for a lower insurance rate, but an alarm system is not a substitute for insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property.

We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved ones to learn about these developments.

- 63 -

LYNXR-IE Installation and Setup Guide

Specifications

LYNXR-IE

Security

Controls

1. Physical: 264 mm (W) x 181 mm (H) x 45 mm (D)

2. Electrical:

VOLTAGE INPUT: 9VAC from plug-in 25VA transformer.

RECHARGEABLE BACKUP BATTERY: Nickel-metal hydride battery pack rated at 7.7Vdc.

ALARM SOUNDER: Piezo = 6-14VDC, 30mA max/ Bell = 6-14VDC, 120mA max

(e.g., ADEMCO’s WAVE2EX).

3. Communication:

ADEMCO Contact ID® Reporting, 10 characters/sec., DTMF (TouchTone) Data

Tones, 1400/2300Hz ACK, 1400Hz KISSOFF.

Line Seize: Double Pole

Ringer Equivalence: 0.6B

- 64 -

LYNXR-IE Installation and Setup Guide

Contacting Technical Support

PLEASE, before you call Technical Support, be sure you:

• READ THE INSTRUCTIONS!

• Check all wiring connections.

• Determine that the power supply and/or backup battery are supplying proper voltages.

• Verify your programming information where applicable.

• Note the proper model number of this product, and the version level (if known) along with any documentation that came with the product.

• Note your Honeywell customer number and/or company name.

Having this information handy will make it easier for us to serve you quickly and effectively.

You may contact Technical Support via Toll Free Fax. Please include your return fax number. You will receive a reply within 24 hours.

Technical Support: ................................................................... 1-800-645-7492 (8 a.m.-8 p.m. E.S.T.)

FAX FAXBACK Automated Fax Retrieval System:......................... 1-800-573-0153 or 1-516-921-6704 / ext. 1667

World Wide Web Address: ......................................................... http://www.honeywell.com/security

- 65 -

LYNXR-IE Installation and Setup Guide

Notes

- 66 -

LYNXR-IE Installation and Setup Guide

Index

*56 Enhanced zone programming mode.................11, 21, 24, 25

*80 Device programming menu mode ....................24, 30, 31, 32

*81 Zone list menu mode ................................................... 24, 33

*83 Enhanced sequential mode .................. 24, 25, 28, 34, 35, 36

*84 Assign zone voice descriptors...........................24, 29, 37, 38

*85 Record custom voice descriptors ................................. 24, 39

*96 Initialize download ID and subscriber acct. no. for downloading......................................................................... 24

C

Callback number ......................................................................24

Cancel report code ....................................................................60

Canceled alarm.........................................................................22

Change the master code ...........................................................48

Chime by zone ....................................................................17, 60

Chime mode ........................................................................17, 49

Closing report ...........................................................................18

*97 Set all program fields to 1 of 4 sets of default values....... 24

*98 Exits programming mode.................................................. 24

*99 Exits programming mode.................................................. 24

1.2-volt nickel-metal hydride batteries ................................... 10

15 second dialer delay........................................................ 21, 60

24-hour audible alarm ............................................................. 16

24-hour auxiliary alarm........................................................... 16

Communication ....................................................................4, 55

Compass downloader................................................................46

Confirmation of arming ding..............................................18, 60

Connecting AC power and backup battery ................................9

Contact ID event codes.............................................................56

Contact ID format.....................................................................48

Contact ID reporting ..........................................................55, 64

24-hour silent alarm .......................................................... 15, 48

A

AC loss report code ............................................................ 22, 60

AC power.............................................................................. 9, 10

AC power and rechargeable backup battery ........................... 10

Contacting technical support ...................................................65

Custom descriptor number.......................................................39

Custom voice descriptors....................................................24, 39

D

Data encryption ........................................................................46

Data field ..................................................................................13

Daylight savings time start/end.........................................17, 60

AC power loss............................................................................. 9

AC restore report code ............................................................. 60

Ademco 1332/1332X10 ............................................................... 9

Alarm bell timeout............................................................. 17, 60

Alarm output.............................................................................. 4

Alarm restore codes ................................................................. 60

Alarm restore report code ........................................................ 22

Alarm sounder ......................................................................... 64

Daylight savings time start/end week......................................17

Default master code..................................................................61

Default tables ...........................................................................61

Delete a secondary security code..............................................48

Delete entire zone list...............................................................33

Arm away/stay report code ................................................ 22, 60

Arm–away ................................................................................ 16

Armed system test ................................................................... 54

Arm–stay.................................................................................. 16

Assign (or change) a secondary security code.......................... 48

Assign custom voice descriptors .............................................. 39

Assign zone voice descriptors ............................................ 37, 60

Delete zone parameters confirmation ................................28, 36

Delete zones..............................................................................33

Descriptor ...........................................................................29, 37

Desktop mounting ......................................................................5

Device action.............................................................................32

Device number..........................................................................32

Disable local sounder..................................................................7

Audible exit warning/quick exit......................................... 18, 60

Audio alarm verification (AAV)/remote phone control............ 23

Audio alarm verification (two-way voice feature) ................... 51

Aux function............................................................................. 50

Aux function/manual message........................................... 23, 60

Away mode ............................................................................... 49

Disarm ................................................................................16, 49

DOD800GY ...............................................................................34

Domonial series transmitters...................................................11

Domonial uni-directional GY series transmitters....................11

Download call back phone number ..........................................24

Download phone number..........................................................61

Download, initial ......................................................................46

Downloader................................................................... 23, 46, 47

Duress code.........................................................................48, 61

B

Babysitter code ........................................................................ 48

Back plate .................................................................................. 5

Backlighting............................................................................. 17

Backup battery..................................................................... 9, 10

Backup reporting ..................................................................... 18

Battery life ............................................................................... 11

E

Enroll mode ........................................................................28, 35

Enter/change the master code..................................................48

Entry delay ................................................................... 18, 57, 60

Entry/exit burglary...................................................................15

Bell ........................................................................................... 64

BR....................................................................................... 11, 26

Burglary zones ......................................................................... 17

Busy-standby ........................................................................... 57

Button transmitters................................................................. 11

Button type .............................................................................. 26

Button zones ............................................................................ 26

Bypass ...................................................................................... 53

Error code 374 ..........................................................................22

Event log 80% full report code ...........................................23, 60

Event logging......................................................................23, 61

Event logging, options ..............................................................23

Exit alarm.................................................................................22

Exit delay................................................................ 17, 18, 57, 60

Exit delay restart ...............................................................18, 49

Bypass report code ............................................................. 22, 60

Bypass restore report code................................................. 22, 60

Exit door ...................................................................................17

Exit error alarm........................................................................57

Exit error report code .........................................................22, 60

Exit warning.............................................................................18

Exiting program mode..............................................................14

Expert programming ................................................................13

External sounder ......................................................................17

- 67 -

LYNXR-IE Installation and Setup Guide

F

Factory defaults....................................................................... 14

Fault................................................................................... 53, 57

FC............................................................................................. 55

Features ..................................................................................... 4

Fire sounder timeout ......................................................... 17, 60

First test report offset........................................................ 21, 60

Flexible callback ...........................................................24, 46, 61

Follow me alarm announcement ............................................. 52

Follow me\ reminder feature .................................................. 52

Follow me reminder” phone number ....................................... 19

Forced bypass ...............................................................17, 50, 60

G

General information ................................................................ 11

General programming information ......................................... 13

H

Handshake frequency .............................................................. 55

Hayes ....................................................................................... 46

House ID .................................................................................. 31

I

Input type .....................................................................11, 26, 61

Installer code ................................................................17, 48, 60

Installer code ........................................................................... 17

Interactive mode ...................................................................... 14

Interior with delay................................................................... 16

Interior, follower...................................................................... 15

K

Keypad backlight timeout ................................................. 17, 60

Keypad functions ............................................................... 49, 50

Keys ......................................................................................... 11

Kissoff frequency ..................................................................... 55

L

Lack of usage notification........................................................ 21

Long range radio and internet communication devices ............ 8

Loop and serial number........................................................... 27

Loop number...................................................................... 27, 61

Low battery report code..................................................... 22, 60

Low battery restore report code ........................................ 22, 60

LYNX-DM .................................................................................. 5

LYNXRCHKIT-HC .................................................................. 10

LYNXRCHKIT-SC................................................................... 10

M

Macro function ......................................................................... 23

Master code.............................................................................. 48

Master security code................................................................ 17

Memory of alarm ..................................................................... 49

Message.................................................................................... 53

Message center ........................................................................ 49

Modem comm ........................................................................... 57

Mounting base ........................................................................... 5

Mute system announcements.................................................. 49

N

No alarm response ................................................................... 16

No delay ................................................................................... 49

Number of reports in armed period................................... 24, 61

O

Open report code................................................................ 22, 60

Operator commands ................................................................ 51

Optima 24 PlusFax 96 modem. ............................................... 46

Other features............................................................................ 4

Other functions........................................................................ 50

- 68 -

P

PABX access code ............................................................... 18, 60

Panic keys.................................................................................48

Perimeter burglary...................................................................15

Periodic test report............................................................. 21, 60

Phone system select ........................................................... 19, 60

Piezo .........................................................................................64

Play back a message.................................................................49

Plug-in transformer....................................................................9

Power up in previous state................................................. 18, 60

Powerline carrier device................................... 17, 30, 31, 52, 60

Powerline carrier device house code ........................................60

Powerline carrier device programming....................................32

Primary phone number ...................................................... 18, 60

Primary subscriber account number.................................. 18, 60

Program mode, entering...........................................................13

Programming default tables .............................................. 60, 61

Programming mode ..................................................................17

Q

Quick exit .................................................................................18

R

Radio and internet communication modules .............................8

Range........................................................................................11

Real time clock display....................................................... 17, 60

REC ..........................................................................................53

Record a message .....................................................................49

Remote phone access................................................................24

Remote phone control...............................................................50

Remote programming...............................................................46

Remote programming/control ............................................ 46, 47

Replacing the rechargeable battery .........................................10

Report code ......................................................................... 21, 26

Report format ..................................................................... 20, 60

Restart exit delay ............................................................... 18, 49

RF .............................................................................................26

RF (supervised RF) ..................................................................11

RF transmitter low battery report code............................. 22, 60

RF transmitter low battery restore..........................................60

RF transmitter low battery restore code .................................22

RF jam ......................................................................................21

Ring detect count for downloading..................................... 24, 61

S

Scheduling .......................................................................... 47, 50

Secondary phone number................................................... 18, 60

Secondary subscriber account number .............................. 18, 60

Secondary user codes ...............................................................48

Security code handshake..........................................................46

Security codes...........................................................................48

Security functions ....................................................................49

Serial number............................................. 24, 25, 28, 29, 34, 35

SH10A ......................................................................................32

Silent burglary .........................................................................16

Single alarm sounding per zone......................................... 17, 60

Siren/horn.................................................................................32

Site-initiated remote programming .........................................46

Smartmodem 1200 ...................................................................46

Smoke detectors .......................................................................59

Sniffer mode ................................................................. 11, 54, 58

Special features ..........................................................................4

Specifications............................................................................64

Split/dual reporting............................................................ 21, 60

Start by event...........................................................................30

Start by zone type ....................................................................30

Start event type........................................................................32

Start zone list ...........................................................................32

Start zone type .........................................................................32

Station-initiated remote programming ................................... 46

Stay mode................................................................................. 49

Stop recording .......................................................................... 49

Stop zone list............................................................................ 32

Stop zone type .......................................................................... 32

Supervised fire ......................................................................... 16

Supervised RF.................................................................... 11, 26

System battery......................................................................... 58

System communication............................................................ 55

System features ......................................................................... 4

System operation ....................................................30, 31, 48, 62

System power............................................................................. 4

System words ........................................................................... 38

T

TC805HF.................................................................................. 34

Technical support..................................................................... 65

Telco handoff............................................................................ 46

Temporal pulse ........................................................................ 17

Test mode ................................................................50, 54, 58, 59

Test report code.................................................................. 22, 60

Test restore report code ........................................................... 60

Testing the system................................................................... 54

Time and date .......................................................................... 50

Transmitter supervision .......................................................... 11

Transmitters ............................................................................ 11

Trouble by day/ ........................................................................ 15

Trouble conditions ................................................................... 57

Trouble report code ............................................................ 22, 60

Trouble restore report code................................................ 22, 60

Troubleshooting guide ............................................................. 57

LYNXR-IE Installation and Setup Guide

U

Unsupervised button RF ..........................................................11

Unsupervised RF......................................................................11

UR (unsupervised RF)........................................................11, 26

User codes.............................................................................4, 50

V

Voice descriptor ............................................................ 26, 29, 37

Voice prompt programming mode ............................................13

Voice vocabulary index.............................................................38

Voltage input ............................................................................64

Volume control..........................................................................49

W

Wall mounting ............................................................................5

WAVE2EX ................................................................................64

Wireless buttons.......................................................................11

Wireless transmitter ................................................................22

Wiring connections .....................................................................7

World wide web address...........................................................65

X

X10................................................................................ 30, 47, 52

Z

Zone bypass ..............................................................................49

Zone descriptor .........................................................................61

Zone entry to list ......................................................................33

Zone list .................................................................. 24, 33, 60, 62

Zone list programming .............................................................33

Zone number................................................................. 26, 34, 37

Zone programming ...................................................................60

Zone response type .............................................................15, 16

Zone type ............................................................................26, 32

Zones and devices .......................................................................4

- 69 -

LYNXR-IE Installation and Setup Guide

- 70 -

OUT T A DA

GND

IN T A DA

CARRIER DEVICES

POWERLINE

Notes: Connection of the fire alarm signal to a fire alarm headquarters or a central station shall be permitted with the approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police emergency number.

The System must be checked by a qualified technician once every three years.

- 71 -

WARRANTY INFORMATION

For the latest warranty information, please go to: www.honeywell.com/security/hsc/resources/wa

ÊK14114-5TŠ

K14114-5 2/09 Rev. A

2 Corporate Center Drive, Suite 100

P.O. Box 9040, Melville, NY 11747

Copyright © 2009 Honeywell International Inc.

www.honeywell.com/security

advertisement