Below you will find brief information for Uplynx-M-RCZ24. This users manual provides comprehensive details on the Uplynx-M-RCZ24 Sigfox Verified modem module, designed for low-power wide-area network (LPWAN) applications. It covers product features, functional descriptions, pin assignments, electrical specifications, and preloaded software including Sigfox AT commands and bootloader. Essential guidance on mounting, connection, power procedures, and RF grounding is also included, enabling users to integrate and operate the module effectively in their embedded designs.

PDF
Document
M2COMM Uplynx-M-RCZ24 User Manual | AI Chat & PDF Download | Manualzz

Advertisement

Advertisement

/

Advertisement

Key features

  • Sigfox Verified™ RF modem

  • Frequency range: 902.1375-904.6625 MHz

  • Maximum output power: 22dBm typical

  • Operating Voltage: 3.4V to 5.5V

  • Operating Temperature: -40°C to 80°C

  • Ultra-low 0.05µA OFF current

  • LGA 29 24mm x 13.5mm form factor with RF IPEX connector

  • Preloaded Sigfox application software and bootloader

  • UART interface with AT command set

  • Module enabling pin (POW_EN) for power management

Frequently asked questions

The module communicates with the host MCU over a UART interface, configured at 9600bps baud rate, 8-bit data, no parity bit, 1 stop bit, and no flow control.

To switch ON, assert POW_EN high after the 5V supply has settled, then wait for 5ms before sending AT commands. To switch OFF, pull POW_EN low and wait at least 10ms before attempting to power ON again.

Firmware can be updated by either pulling pin 16 (STATUS) low at startup to enter XMODEM mode via UART at 115200bps, or by entering the AT$FW=1 command while the Sigfox AT command interface is running, which then puts the module into XMODEM mode for updating.

For RCZ2, the recommended settings are AT$IF=902200000 for transmission frequency and AT$400=1,0,0,1 for Sigfox configuration words. Ensure the RCZ region is set by AT$RCZ then execute AT$O=1,X.

The Uplynx-M-RCZ24 module has a typical maximum output power of 22dBm.