VERY IMPORTANT
Please read this instruction guide before install and using your portable air conditioner unit.
This instruction manual is the universal-purpose version for the units that you purchase, it might be slightly different from the ones described in the manual, but it does not affect your proper operations and usage.
CAUTION
1. " PLEASE MAKE SURE THE PRODUCT VENTILATES ALL THE TIME "!
Please make sure the inlet and outlet ventilation is not blocked at all times.
2. Operate this unit on a horizontal surface to avoid water leakage.
3. Do not operate this unit in an explosive or corrosive atmosphere.
4. Operate this unit in an ambient of 35 degree centigrade or less.
5. The heating function of the unit should be operated in an indoor ambient temperature between 7℃ and 23℃
6. Clean air filter periodically to enjoy the most efficient cooling.
7. When the unit is shut off, please wait at least 3.5 minutes before restarting this is to prevent the compressor from being damaged.
8. This unit needs at least 7 Amps of electricity to have its compressor operational. To avoid the household electricity block out, please do not use any extension cord for this unit.
9. This unit is for indoor cooling, heating and dehumidifying.
10. When turning on the unit, the fan will operate but the compressor will start up after the cooling alarm flashes for three minutes
●
In heating function, the heating alarm will flash for 3.5 minutes before the compressor and fan start up.
11. When the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid hazard.
1
12.In order to dispose the appliance safely, please remove the batteries from the unit before scrapping it.
13. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
14. The air-conditioner can be connected only to a supply with system impedance no more than 0.219Ω.In case necessary, please consult your supply authority for system impedance information.
ATTENTION
For effective heating and cooling functions, please ensure that the following steps are undertaken:
1) Extend the exhaust hose to a length of not more than 400mm. The exhaust hose must be kept parallel and must not be bent up or down.
2) A distance of 500mm minimum must be kept between the filter side of the unit and wall or any other obstacles”.
3) When this appliance starts to defrost, the word “DF” will be displayed on the LED
2
CONGRATULATIONS ON YOUR
SELECTION OF A QUALITY
PORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER
This Air Conditioner has been designed and manufactured to the highest standards of modern engineering.
Our product not only provides you a remote control to help user operate all the functions easily and conveniently but also has below benefits:
- Moves easily from room to room on easy glide castors
- No installation required-just plug into any household
power outlet
Powerful refrigerated air system cools down the ambience instantly whenever you want.
Dehumidified and filtered air cycle improve breathing environments effectively.
- Besides the remote control, your one touch electronic pad also provides easy-identifying manual operation.
- 24 hour programmable timer that can be used with either the air conditioning or dehumidification setting
- Unique sleep control function
- 220-240 Volt 50Hz operation
- 1.8 meter cord with plug
3
UNPACKING INSTRUCTIONS
1. Place the unit in the correct upright position before unpacking.
2. Cut the two packing straps.
3. Slide the carton in an upwards motion and it will release from the base.
4. Grip the carry handles located on either sides of the unit and carefully lift until it slides out of the foam base.
5. Remove the air outlet and take out the exhaust hose as the picture.
6. Install the exhaust hose on the unit before operating the unit.
CONTENTS
1 / Air conditioner unit
2 / Remote control
3 / Batteries
4 / Window Kit A
4
NAME OF THE PARTS
1. Control panel
2. Remote control receiver
3. Adjustable air vent
4. Joint tube
5. Exhaust hose
6. Upside drain hole
7. Air freshener slot
8. Cool air inlet
9. Cool air filter
10. Hot air inlet
11. Hot air filter
12. Downside drain hole
5
CONTROL PANEL & DESCRIPTION OF FUNCTION
1. POWER KEY
Press to turn unit "ON" or "OFF".
2. FUNCTION
Press this key to select cooling, heating, or dehumidifying.
3. TEMPERATURE REGULATION KEY (UP)
During cooling function:This key raises the preset temperature by 1℃ each time it is pressed and the maximum limit is 30℃.
During heating function: This key raises the preset temperature by 1℃ each time it is pressed and the maximum limit is 25℃.
6
4. TEMPERATURE REGULATION KEY (DOWN)
During cooling function:This key lowers the preset temperature by 1℃ each time it is pressed and the minimum limit is 17℃.
During heating function:This key lowers the preset temperature by 1℃ each time and the minimum limit is 15℃.
5. L.E.D. DISPLAY
The display indicates the current setting temperature or the timer setting. When the set temperature or the timer is adjusted, the new setting is shown then the display returns the current set temperature.
※ The display is also used to show error codes should a fault occur, see ERROR
CODES.
6. SPEED
Press to select either LOW, MEDIUM, HIGH or AUTO fan speed.
If "AUTO" is selected (During cooling function),”HIGH” or "MEDIUM" or “LOW" will be
selected automatically according to the difference between setting temperature and
ambient temperature.
Note: In heating function and dehumidifying function, this key is invalid because the unit is defined to be high speed in heating mode and low speed in dehumidifying mode.
7. PROGRAMMABLE TIMER
Programmable timer ON/OFF key.
TIMER-ON: The timer-on is used to turn on the unit automatically after the set time is over.
1. Press the "TIMER" key at stand-by status to set the time you desired.
2. Once the set hour has come to an end, the unit will turn on automatically.
3. Press the "POWER" key before time out, the setting time will be canceled and the unit will turn on.
4. You can set the function and fan speed while setting the timer.
7
TIMER-OFF: The timer-off is used to turn off the unit automatically after the setting time is over.
1. Press the "TIMER" key at operating status to set the time you desired.
2. Once the set hour has come to an end, the unit will turn off automatically.
3. Press the "POWER" key before the time out, the setting time will be canceled and the unit will turn off.
8. SLEEP CONTROL FUNCTION
1. While in cooling mode, press the SLEEP key to set the temperature. It increases1 ℃ after an hour and at most increases 2 ℃ after 2 hours.
2. While in heating mode, press the SLEEP key to set the temperature. It decreases
1 ℃ after an hour and at most decreases 2 ℃ after 2 hours.
3. Press the SLEEP key again can cancel the setting.
9. ALARM
When the water tank is full,"E4" will be displayed on the display panel. To resume operation, please remove the rubber cap of the drain hose to drain out the water firstly.
The E4 warning will disappear after draining, and then you can restart the unit by pressing the POWER key.
8
REMOTE CONTROL FUNCTION
1. POWER
2. FUNC
3. TIMER
4. AUTO
5. HI
6. MID
7. LOW
8. SLEEP
9. TEMP.
On/Off switch
Function “MODE” selector
Hourly programming
Automatic fan speed
High fan speed
Medium fan speed
Low fan speed
Night operation selector
Temperature selector
9
NOTICE
This unit can evaporate the condensation and distribute through the exhaust hose automatically.
1. When the unit is in the cooling function, it does not need the drain pipe installed.
Please make sure that the rubber cap is locked on drain hole, when the unit is running.
2. When operating the heating function, the “①” rubber cap on drain hole should be pulled out and install a proper drain pipe in order to improve the heating effect
3. When operating the dehumidifying function the “①” rubber cap on drain hose should be pulled out and install a proper drain hose.
● Please remove the air exhaust hose, connect a drain hose to the drain hole and lead the water to the outside in order to intensify dehumidifying capacity.
※ When the water tank is full,"E4" will be displayed on the display panel. Please remove the rubber cap“②” of the drain hole to drain out the water first. After the drainage is completed, please restart the unit and then the unit can operate normally.
MAINTENANCE
PLEASE DISCONNECT THE POWER CORD BEFORE CLEANING.
AIR FILTER
The air filter located on the left hand side of the unit can be removed, simply by pulling the frame out
10
CONDENSER/EVAPORATOR
Use a brush attachment with a vacuum cleaner.
Casing
Wipe with a damp cloth and polish with a soft cloth.
To remove the air filter, please follows the arrow direction and pull the filter lightly, and then take out the filter for cleaning.
11
POWER SUPPLY
(1) Confirm the correct power.
(2) Insert the plug into the outlet firmly In order to prevent any dangerous leakage.
(3) Don’t pull power wire by force because it will cause damage to power wire.
PLACE FOR USE
(1) Because the machine distributes hot air, please don’t place or operate in a narrow place.
(2) In case of dangerous leak, don’t work the machine in a humid place.
(3) Don’ t place the machine in a sunlit corner otherwise the unit might shut down due to the overheat and the color of the machine may soon fade out.
HELPFUL HINTS
The unit is fitted with a special thermal cut off device.
Please ensure the unit is not placed against objects which will obstruct air intake e.g. furniture or curtains as this will affect it's
performance dramatically.
12
EXHAUST HOSE INSTALL
1.
Circumrotate the exhaust hose according to the direction as the arrowhead ① indicates and then the exhaust hose can be took out from the unit.
2.
Circumrotate the exhaust hose according to the direction as the arrowhead ② indicates and then make it connect with the unit.
WINDOW KIT INSTALL
Install the Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.1 & Fig.1a.
13
How to enjoy heating function?
When operating heating function:
Disassemble the outlet and the exhaust hose as arrow direction in Fig.01 and then exchange the two subassemblies to install. The finished illustration is as Fig.03.
TROUBLE SHOOTING
Problem Cause
E1
E2
E4
Electrical short on both temperature sensor and PCB
Electrical short of temperature sensor copper tube and PCB wiring
Indicates water tank full or possibly the incorrect wiring of plug
Trouble shooting
Contact an electrician for repair
Contact an electrician for repair
User needs to pull out the rubber stopper which is located at the bottom of the unit, to drain the water away. Check that the plug has been wired correctly.
14
SPECIFICATION
Model No.
PC30-AM1BII
Power Source
Rated Power (EN60335)
Cooling
Heating
Cooling Capacity
Heating Capacity
220-240V~50Hz
1280W
1100W
3000W
3000W
220-240V~50Hz
1700W
1500W
4400W
4400W
Moisture Removed 50liters/day 70liters/day
Refrigerant R410A R410A
Dimensions (mm) 300Wx480Dx630H
(CE) N 842/2006:
R410A is a kind of fluorinated greenhouse gases covered by the Kyoto Protocol.
Its total global warming potential (GWP) is 2088.
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible hazards to the environment or human health from uncontrolled waste disposal, please recycle it to prove the sustainable reuse of material resources. Please ask return and collection systems or contact the retailer where the product was purchased to return your used device, they can recycle products safely.