PC30-AM1BII / PC44-AM1B USER MANUAL

PC30-AM1BII / PC44-AM1B USER MANUAL
VERY IMPORTANT
Please read this instruction guide before install and using
your portable air conditioner unit.
This instruction manual is the universal-purpose version
for the units that you purchase, it might be slightly
different from the ones described in the manual, but it does
PC30-AM1BII / PC44-AM1B
USER MANUAL
not affect your proper operations and usage.
CAUTION
1. " PLEASE MAKE SURE THE PRODUCT VENTILATES ALL THE TIME "!
Please make sure the inlet and outlet ventilation is not blocked at all times.
2. Operate this unit on a horizontal surface to avoid water leakage.
3. Do not operate this unit in an explosive or corrosive atmosphere.
4. Operate this unit in an ambient of 35 degree centigrade or less.
5. The heating function of the unit should
be operated in an indoor ambient
temperature between 7℃ and 23℃
6. Clean air filter periodically to enjoy the most efficient cooling.
7. When the unit is shut off, please wait at least 3.5 minutes before restarting
this is to prevent the compressor from being damaged.
8. This unit needs at least 7 Amps of electricity to have its compressor
operational. To avoid the household electricity block out, please do not use
any extension cord for this unit.
9. This unit is for indoor cooling, heating and dehumidifying.
10. When turning on the unit, the fan will operate but the compressor will
start up after the cooling alarm flashes for three minutes
●
In heating function, the heating alarm will flash for 3.5 minutes before
the compressor and fan start up.
PORTABLE AIR-CONDITIONER
11. When the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to avoid hazard.
1
12.In order to dispose the appliance safely, please remove the batteries from the
unit before scrapping it.
13. This appliance is not intended for use by persons (including children) with
CONGRATULATIONS ON YOUR
SELECTION OF A QUALITY
PORTABLE AIR CONDITIONER
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
PORTABLE AIR CONDITIONER
use of the appliance by a person responsible for their safety. Children should
This Air Conditioner has been designed and manufactured to the
be supervised to ensure that they do not play with the appliance.
highest standards of modern engineering.
14. The air-conditioner can be connected only to a supply with system impedance
Our product not only provides you a remote control to help user
no more than 0.219Ω.In case necessary, please consult your supply authority
operate all the functions easily and conveniently but also has below
for system impedance information.
benefits:
- Moves easily from room to room on easy glide castors
ATTENTION
- No installation required-just plug into any household
For effective heating and cooling functions, please
ensure that the following steps are undertaken:
1)
Extend the exhaust hose to a length of not
more than 400mm. The exhaust hose must
be kept parallel and must not be bent up or
A distance of 500mm minimum must be kept
between the filter side of the unit and wall or
instantly whenever you want.
- Dehumidified and filtered air cycle improve breathing
environments effectively.
also provides easy-identifying manual operation.
- 24 hour programmable timer that can be used with either the
air conditioning or dehumidification setting
any other obstacles”.
3)
- Powerful refrigerated air system cools down the ambience
- Besides the remote control, your one touch electronic pad
down.
2)
power outlet
When this appliance starts to defrost, the
- Unique sleep control function
word “DF” will be displayed on the LED
- 220-240 Volt 50Hz operation
- 1.8 meter cord with plug
2
3
UNPACKING INSTRUCTIONS
NAME OF THE PARTS
1.
Place the unit in the correct upright position before unpacking.
1. Control panel
2.
Cut the two packing straps.
2. Remote control receiver
3.
Slide the carton in an upwards motion and it will release from the base.
3. Adjustable air vent
4.
Grip the carry handles located on either sides of the unit and carefully lift until it
4. Joint tube
slides out of the foam base.
5. Exhaust hose
Remove the air outlet and take out the
6. Upside drain hole
exhaust hose as the picture.
7. Air freshener slot
5.
6.
Install the exhaust hose on the unit
before operating the unit.
CONTENTS
1 / Air conditioner unit
2 / Remote control
3 / Batteries
8. Cool air inlet
4 / Window Kit A
9. Cool air filter
10. Hot air inlet
11. Hot air filter
12. Downside drain hole
4
5
4.
CONTROL PANEL & DESCRIPTION OF FUNCTION
TEMPERATURE REGULATION KEY (DOWN)
During cooling function:This key lowers the preset temperature by 1℃ each time it is
pressed and the minimum limit is 17℃.
During heating function:This key lowers the preset temperature by 1℃ each time and
the minimum limit is 15℃.
5. L.E.D. DISPLAY
The display indicates the current setting temperature or the timer setting. When the set
temperature or the timer is adjusted, the new setting is shown then the display returns the
current set temperature.
※ The display is also used to show error codes should a fault occur, see ERROR
CODES.
6.
SPEED
Press to select either LOW, MEDIUM, HIGH or AUTO fan speed.
If "AUTO" is selected (During cooling function),”HIGH” or "MEDIUM" or “LOW" will be
selected automatically according to the difference between setting temperature and
ambient temperature.
Note: In heating function and dehumidifying function, this key is invalid because
the unit is defined to be high speed in heating mode and low speed in
1.
dehumidifying mode.
POWER KEY
Press to turn unit "ON" or "OFF".
2.
7.
FUNCTION
Programmable timer ON/OFF key.
Press this key to select cooling, heating, or dehumidifying.
3.
PROGRAMMABLE TIMER
TEMPERATURE REGULATION KEY (UP)
During cooling function:This key raises the preset temperature by 1℃ each time it is
pressed and the maximum limit is 30℃.
During heating function:This key raises the preset temperature by 1℃ each time it is
pressed and the maximum limit is 25℃.
TIMER-ON: The timer-on is used to turn on the unit automatically after the set time is
over.
1. Press the "TIMER" key at stand-by status to set the time you desired.
2. Once the set hour has come to an end, the unit will turn on automatically.
3. Press the "POWER" key before time out, the setting time will be canceled and the
unit will turn on.
4. You can set the function and fan speed while setting the timer.
6
7
TIMER-OFF: The timer-off is used to turn off the unit automatically after the setting
REMOTE CONTROL FUNCTION
time is over.
1. Press the "TIMER" key at operating status to set the time you desired.
2. Once the set hour has come to an end, the unit will turn off automatically.
3. Press the "POWER" key before the time out, the setting time will be canceled and
the unit will turn off.
8.
SLEEP CONTROL FUNCTION
1. While in cooling mode, press the SLEEP key to set the temperature. It increases1 ℃
after an hour and at most increases 2 ℃ after 2 hours.
2. While in heating mode, press the SLEEP key to set the temperature. It decreases
1 ℃ after an hour and at most decreases 2 ℃ after 2 hours.
3. Press the SLEEP key again can cancel the setting.
9.
ALARM
When the water tank is full,"E4" will be displayed on the display panel. To resume
operation, please remove the rubber cap of the drain hose to drain out the water firstly.
The E4 warning will disappear after draining, and then you can restart the unit by
pressing the POWER key.
8
1. POWER
On/Off switch
2. FUNC
Function “MODE” selector
3. TIMER
Hourly programming
4. AUTO
Automatic fan speed
5. HI
High fan speed
6. MID
Medium fan speed
7. LOW
Low fan speed
8. SLEEP
Night operation selector
9. TEMP.
Temperature selector
9
CONDENSER/EVAPORATOR
NOTICE
Use a brush attachment with a vacuum cleaner.
This unit can evaporate the condensation and distribute through the exhaust hose
automatically.
1. When the unit is in the cooling function, it does not need the drain pipe installed.
Please make sure that the rubber cap is locked on drain hole, when the unit is
Casing
Wipe with a damp cloth and polish with a soft cloth.
running.
2. When operating the heating function, the “①” rubber cap on drain hole should be
pulled out and install a proper drain pipe in order to improve the heating effect
3. When operating the dehumidifying function the “①” rubber cap on drain hose should
be pulled out and install a proper drain hose.
● Please remove the air exhaust hose, connect a drain hose to the drain hole and
lead the water to the outside in order to intensify dehumidifying capacity.
※ When the water tank is full,"E4" will be displayed on the display panel. Please
remove the rubber cap“②” of the drain hole to drain out the water first. After the
drainage is completed, please restart the unit and then the unit can operate
normally.
To remove the air filter, please follows the arrow direction and pull the
filter lightly, and then take out the filter for cleaning.
MAINTENANCE
PLEASE DISCONNECT THE POWER CORD BEFORE CLEANING.
AIR FILTER
The air filter located on the left hand side of the unit can be removed,
simply by pulling the frame out
10
11
POWER SUPPLY
EXHAUST HOSE INSTALL
(1) Confirm the correct power.
1. Circumrotate the exhaust hose according to the direction as the arrowhead ①
(2) Insert the plug into the outlet firmly In order to prevent any
dangerous leakage.
indicates and then the exhaust hose can be took out from the unit.
2. Circumrotate the exhaust hose according to the direction as the arrowhead ②
(3) Don’t pull power wire by force because it will cause damage to power
indicates and then make it connect with the unit.
wire.
PLACE FOR USE
(1) Because the machine distributes hot air, please don’t place or
operate in a narrow place.
(2) In case of dangerous leak, don’t work the machine in a humid place.
(3) Don’ t place the machine in a sunlit corner otherwise the unit might
shut down due to the overheat and the color of the machine may
WINDOW KIT INSTALL

Install the Exhaust Hose and the Adjustable Window Slider Kit as
depicted in Fig.1 & Fig.1a.
soon fade out.
HELPFUL HINTS
The unit is fitted with a special thermal cut off device.
Please ensure the unit is not placed against objects which will
obstruct air intake e.g. furniture or curtains as this will affect it's
performance dramatically.
12
13
How to enjoy heating function?
SPECIFICATION
Model No.
Power Source
Rated Power (EN60335)
Cooling
Heating
PC44-AM1B
220-240V~50Hz
220-240V~50Hz
1280W
1100W
1700W
1500W
Cooling Capacity
3000W
4400W
Heating Capacity
3000W
4400W
50liters/day
70liters/day
R410A
R410A
300Wx480Dx630H
300Wx505Dx778H
Moisture Removed
Refrigerant
When operating heating function:
PC30-AM1BII
Dimensions (mm)
Disassemble the outlet and the exhaust hose as arrow direction in Fig.01 and then
exchange the two subassemblies to install. The finished illustration is as Fig.03.
(CE) N 842/2006:
R410A is a kind of fluorinated greenhouse gases covered by
the Kyoto Protocol.
TROUBLE SHOOTING
Problem
E1
Its total global warming potential (GWP) is 2088.
Cause
Trouble shooting
Electrical short on both
Contact an electrician for repair
temperature sensor and PCB
E2
Contact an electrician for repair
Electrical short of temperature
sensor copper tube and PCB
wiring
E4
Indicates water tank full or
User needs to pull out the rubber stopper
possibly the incorrect wiring of
which is located at the bottom of the unit,
plug
to drain the water away. Check that the
plug has been wired correctly.
14
This marking indicates that this product should not be disposed with
other household wastes throughout the EU. To prevent possible
hazards to the environment or human health from uncontrolled waste
disposal, please recycle it to prove the sustainable reuse of material
resources. Please ask return and collection systems or contact the
retailer where the product was purchased to return your used device,
they can recycle products safely.
15
Was this manual useful for you? yes no