Evikon E2610-CO Carbon Monoxide detector User Manual

Add to My manuals
11 Pages

advertisement

Evikon E2610-CO Carbon Monoxide detector User Manual | Manualzz

Carbon Monoxide Detector

E2610-CO

User Manual

E2610-CO

Table of contents

Carbon Monoxide

Specifications

Product description

Safety requirements

Operating conditions

Installation guidelines

Connections

Operation

Maintenance

Calibration

Delivery set

Order code for E2610-CO options

Warranty

Manufacturer contacts

Rev 29.07.2022

10

10

11

11

9

9

9

5

5

5

3

4

6

7

2

E2610-CO Rev 29.07.2022

Carbon Monoxide

A Colorless, odorless, and tasteless gas that is highly toxic. Carbon monoxide is formed as a result of incomplete combustion of carbon-containing compounds, e.g. while operating a furnace, an oven, or an engine when there is a limited supply of air.

Synonyms: Carbonous oxide, Carbon (II) oxide, Flue gas, Monoxide

Chemical formula

Molar weight

Relative gas density (to air)

Conversion

Boiling point

Low explosive limit (LEL), % vol. in air

Upper explosive limit (UEL), % vol. in air

Odor

Hazards

Exposure limits (ACGIH)

TWA

STEL

CO

28

0,97

1 ppm= 1.15 mg/m 3

-191.5 °C

12.5

74 odorless

Highly toxic. Mild poisoning causes lightheadedness, confusion, headache, dizziness, and flu-like effects.

Larger exposures can lead to toxicity of the CNS and heart, and death. After acute poisoning, long-term problems may occur. CO also has negative effects on a baby if exposed during pregnancy. Chronic exposure to low levels can lead to depression, confusion, and memory loss.

40 mg/m 3 /35 ppm

1380 mg/m 3 /1200 ppm

Conversion of ppm to mg/m 3 is calculated for 25°C and 1 atm.

3

E2610-CO Rev 29.07.2022

Specifications

Sensor type

Sampling method

Typical detection range

Alarm setpoints

(release-LOW-HIGH)

Resolution / digital unit

Accuracy

Response time T90

Sensor lifetime

Calibration interval

Power supply

Power consumption

Digital interface

Relay outputs

Alarm

Enclosure

Dimensions

CE marking

Operating conditions

0...200 ppm

18 - 25 - 125 ppm

Electrochemical cell

Diffusion

0...1000 ppm

88 - 125 - 250 ppm

1 ppm

±(3% of range + 5 ppm CO)

< 30 seconds

> 10 years

12 months

24 VDC/AC ±20% (default) or 230 VAC (optional)

< 2 VA

UART

2 × SPDT, max 5 A, 30 VDC / 250 VAC

Buzzer 85 dB

ABS plastic with ventilation slots, wall-mount, protection class IP20

H85 × W85 × D37 mm

According to 2014/30/EU and 2014/35/EU, EN 50491-4-1:2012

EN 61000-6-3:2020, EN 61326-1:2013(EMC, emissions)

EN 61000-6-1:2019, EN 61000-6-2:2019(EMC, Immunity)

EN 60079-29-1:2016, EN 60079-29-2:2015 and EN 60079-29-3:2014

-20...50°C, 15...95% RH without condensation, 0,9...1,1 atm;

Non-ATEX-rated areas

Avoid strong mechanical shock, vibrations or EMI Avoid exposure to corrosive gases

NOTE! The sensor may exhibit sensitivity to acetylene, ethylene, hydrogen, and nitric oxide.

4

E2610-CO Rev 29.07.2022

Product description

E2610 series gas detectors are compact and easy-to-use instruments. The devices utilize novel fully calibrated and temperature compensated gas sensors with excellent repeatability, stability, and long lifetime.

Two relays with switch-over contact may be used for remote signaling or ventilation control. Flashing LED and an internal buzzer give alarms at two setpoints.

Safety requirements

Misuse will impair the protection of the product. Always adhere to the safety provisions applicable in the country of use.

Do not perform any maintenance operation with the power on. Do not let water or foreign objects inside the device.

Removal of the PCB from the enclosure voids the warranty. Do not touch the electronic components directly, as they are sensitive to static electricity.

Connection diagrams can be found in the connections section. The device might not perform correctly or be damaged if the wrong power supply is connected.

External circuits connected to the equipment should have sufficient insulation rating according to the environmental conditions and equipment power.

A disconnecting device that is marked as such and easily accessible should be included in the installation of this product.

Operating conditions

The device should be used both in a non-hazardous indoor area and in a basic electromagnetic environment, where the latter is defined in EN 61326-1. Avoid strong mechanical shock and vibrations. Avoid corrosive atmosphere and areas highly contaminated with dust, oil mist, etc. Keep the instrument away from direct sunlight. A sudden temperature or humidity change might affect the sensitivity of the sensor.

5

E2610-CO Rev 29.07.2022

Installation guidelines

There are no precise rules or standards to follow when installing gas detectors. The following points must be taken into account:

● Application (the instrument is intended for leakage control.)

● Properties of the space under investigation (room geometry, direction, and velocity of airflows, etc.),

● Carbon monoxide has practically the same density as air and spreads evenly in the room. Install the sensor in proximity to possible leakage or generation source, taking into consideration the temperature of the gas, the air currents in the room, etc.

● The device should be accessible for maintenance and repair.

The aforementioned conditions above will affect the coverage area of the device. however, the coverage area for a detector is usually between 2.5 to 5 meters radius.

For early leakage detection install the sensor as close as possible to the potential leakage sources (flanges, valves, pressure reducers, pumps, etc.), taking into consideration other points listed above.

For general area monitoring without definite leakage sources, the detector should be distributed evenly in the room.

Do not locate the detector close to ventilation openings and strong air currents. Avoid the areas without air circulation (corners, niches) as well.

For personal safety control, the detectors are installed in the breathing zone (at the height of the head of people or animals). The recommended sensor position is vertical, pointing downwards.

6

E2610-CO

Connections

1. Detach the base of the enclosure by gently pulling along four guiding pins.

2. Attach the base to the wall with two screws. (see drawings below).

Rev 29.07.2022

3. Use rounded cutouts on the side of the base to let in the cables from the power supply and of the external devices as shown below.

7

E2610-CO Rev 29.07.2022

For easier connection, terminal blocks of E2610 series devices are removable. To dismount the terminal block, pull it off from the PCB. Connect the power terminals N and L to the 24

V power source if you are using detector version -24 or to 230 V AC mains if you are using detector version -230 (see diagram below).

Terminals

RE1 NO

RE1 COM

RE1 NC

RE2 NO

RE2 COM

RE2 NC

L

N

Relay 1, normally open terminal

Relay 1, common terminal

Relay 1, normally closed terminal

Relay 2, normally open terminal

Relay 2, common terminal

Relay 2, normally closed terminal

90…265 VAC Phase (optional 24 VAC / VDC)

90…265 VAC Neutral (optional 24 VAC / VDC)

The terminals on the E2610 series devices are suitable for a wide range of wires with cross-section 0,2...1,5 mm 2 . We recommend to strip the wire end by 5...6 mm and tin it, or to use the wire end sleeves. To connect the wire, loosen the screw, insert the wire end into the terminal hole and tighten the screw.

Connect external devices. Relay switch-over outputs may be used to control directly 24 V or

230 V (for versions -24 and -230 respectively) powered alarm sirens, ventilation fans, shut-off valves, or other actuators. Attach terminal blocks to the board.

4. Push enclosure to the base.

8

E2610-CO Rev 29.07.2022

Operation

Turn on the power. During the first ca.60 seconds after powering on E2610 performs a warming-up and self-diagnostic routine, indicated by the flashing of each LED. The upper dual-color LED remains continuously green in normal operation and blinks red in case of device or sensor fault.

The warm-up time depends on the sensor type, unpowered period, and atmosphere. During the first 30 seconds after powering on you may select the automatic or manual mode of alarm release. By shortly (< 2 s) pressing the button on the device’s front panel you enable the automatic mode, by pressing the button for 2...10 s — manual mode. The activation of the automatic mode is followed by a single LED blinking and acoustic signal. If manual mode is activated, the double acoustic and light signal follows.

If the gas concentration exceeds the LOW alarm setpoint, the bottom red LED starts flashing at a rate of 1 Hz, and the relay RE1 switches over. The first alarm stops automatically if the gas concentration drops below 70% of the LOW alarm setpoint.

If the gas level exceeds the HIGH alarm setpoint, the bottom red LED starts flashing and the buzzer starts beeping at a rate of 2 Hz, and also the relay RE2 switches over.

Depending on the selected release mode, the HIGH alarm stops automatically or can be stopped by pressing the button, on condition that the gas level has dropped below 70% of the LOW alarm setpoint.

Beyond the warm-up period, holding down the button for 2...10 seconds and releasing causes E2610 to reset and perform the self-diagnostic routine for testing purposes. When holding the button down for over 10 seconds, E2610 imitates the reaching of the HIGH setpoint with the respective light and sound indication and switching over the relays.

Maintenance

Do not perform any maintenance operation with the power on.

Clean the device with a soft damp cloth. Do not use any abrasive cleaning agents. Do not immerse the device in water or any cleaning media.

Calibration

E2610-CO detectors have been calibrated by the Manufacturer with standard gas mixtures before delivery. Provided that the sensor is used under moderate conditions, field recalibration is recommended every 12 months Please contact your dealer for more information.

9

E2610-CO

Delivery set

● Carbon Monoxide Detector E2610-CO

● Mounting accessories:

○ 2 screws and 2 plastic dowel plugs

Order code for E2610-CO options

E2610 options

Integrated 90...265 V mains power supply module

Integrated 24 VAC power supply module

Order code

E2610-CO-230

E2610-CO-24VAC

Rev 29.07.2022

10

E2610-CO Rev 29.07.2022

Warranty

This product is warranted to be free from defects in material and workmanship for a period of one year from the date of the original sale. During this warranty period, the Manufacturer will, at its option, either repair or replace a product that proves to be defective. This warranty is void if the product has been operated in conditions outside ranges specified by the Manufacturer or damaged by customer error or negligence or if there has been an unauthorized modification.

Manufacturer contacts

Evikon MCI OÜ

Teaduspargi 7/9, Tartu

50411 Estonia [email protected]

www.evikon.eu