ZyAura ZG906CMONP Operating Instructions
Add to My manuals2 Pages
The ZyAura ZG906CMONP is a handheld multi-gas detector designed to measure CO2, CO, O2, NH3, PM2.5, and PM10 concentrations in the environment. It features dual-beam NDIR technology for CO2 measurement, a large LCD display, data logging with SD card, and RS485 interface for remote monitoring. This device is ideal for use in paint-related industries, wineries, food industry, laboratories, and construction sites, among others.
advertisement
▼
Scroll to page 2
Handheld Multi Gas Detector Operating Instructions Model: ZG906CMONP Product Overview Thank you for selecting ZG906CMONP handheld multi gas detector. The ZG906CMONP is designed to simultaneously measure multiple gas concentrations in the ambient environment. With long-term data storage, the user can assess the environmental friendliness. When ZG906CMONP measures the gas concentration reaching the alarm setting or higher, the data display and alarm functions are activated. ZG906CMONP is equipped with an RS485 interface for connecting to a computer for remote monitoring so as to reduce the risk of exposure to high concentrations of harmful gases and avoid harm to human health. ZG906CMONP can be used in a wide range of industries, which include paint-related industries, wineries, related industries of CO2, food industry, laboratory, construction industry, etc. Features: □ V刈 Dual beam NDIR (Non-Dispersive-Infrared) technology is used to measure CO2 concentration and improve the long term stability. □ V Measurement items: A E A A E A @ A A A A A A E A E A E A E A E A O2 concentration (%) 氖 NH3 concentration ppm (parts per million) 氖 Battery capacity 此 Atmospheric pressure 此 setting sequence is: yearàmonthàdateàhouràminute. After finishing the real-time setting, press the “M1” key ( 此 F ) to continue the alarm setting. A Time weighted average (8 hours) Optional: O2, NH3 □ V Large LCD for easy reading of gas concentration and temperature and humidity. □ V刈 Audible alarm □ V刈 Data logging with SD card □ V Through the RS485 interface connection, multiple ZG906CMONP units can be connected to the back-end computer system as a security monitoring application.刈 □ V Built in the LCD backlight for easy reading in the dark.刈 □ V This device is supplied with Li- ion 18650 3.7V rechargeable batteries, can be used for a long time. E 氖 E A Alarm settings: The setting order of the sensors is CO2àCOàO2àHN3àPM2.5. Press the "Enter" key ( 此 I ) to switch the high/low gas concentration alarm setting. Press “▲( 此 G )/▼( 此 J )” key to edit the parameters, and then press the “M1” key ( 此 F ) to proceed the next sensor alarm value settings. After settings, press and hold the “M1” key (此 F ) to return to the main screen. A A Basic: CO2, CO, PM2.5, PM10, RH, DP, AMB, Barometer A PM10 dust concentration (µg/m3) 此 Short#Term Exposure Limit (15 min. weighted average) 此 Maximum value 此 Minimum value 此 Ambient temperature 此 Relative humidity 此 A A Dew point 此 Real-time setting display 此 Year display 此 High/low gas concentration calibration 此 High/low gas concentration alarm 此 Display cycle 此 SD card 此 E E B. Humidity Sensor C. Temperature Sensor D. LCD E. Charge Lamp F. M1 (Zone 1 Mode Key) G. UP\TWA\STEL\Max\Min H. M2 (Zone 2 Mode Key) I. Enter J. DOWN\ALTI K. Log (Data Logger) L. USB Socket M. SD Card Slot N. RS485 Jack O. Battery Cover P. Stand Q. Screw Position R. Tripod Screw E A A E A A E A A E A A E A A E A A Sensor 1 2 3 4 CO2 CO O2 NH3 PM2.5 PM10 Warm-up time Data logging interval time setting 5 minutes After powering on and standby time, data logging can be operated. After power on 5 minutes After power on 5 minutes After power on 5 minutes After power on 5 minutes Data logging interval time setting 2 seconds~60 minutes 2 seconds~60 minutes 2 seconds~60 minutes 2 seconds~60 minutes 自1 minute After power on 5 minutes 2 seconds~60 minutes 自1 minute 5 minutes 自1 minute Data logging: Press the “Log” key ( 此 K ) for 3 seconds and the screen displays A E to start the data logging function. If A long press the “Log” key ( 此 K ),this function can be canceled. When broken or full; when E E flashes, it means that the SD card is A remains stationary, it indicates normal operation. A E A A A H ) for more than 3 seconds and the screen displays . Zone 2 displays readings Press the “M2” key ( 此 of all sensors sequentially in time intervals. If you need to increase the display interval time, long press the “M2” key ( 此 H ).The interval time will automatically increase (1+0.5+0.5….. max. 10 seconds) , and release the “M2” key ( 此 H ), the readings will be displayed according to the last set interval. If press the “M2” key ( 此 H ) A E E PM2.5 dust concentration (µg/m 此 A A E A A again for more than 3 seconds, the E A function can be cancelled. °C/°F switch: When the temperature is displayed on the screen, press the "▲" key ( 此 G ) to switch °C/°F. A E A Atmospheric pressure display: J ), and then press "▲" key ( 此 G ) to select Altitude (M) à Altitude (ft) à Barometer Press "▼" key ( 此 (mmHg). The display returns to the main screen after 10 seconds. A 此 A A 此 CO concentration, parts per million (ppm) E E Display all sensor readings A Basic此刈 Optional氖 Data logging interval time setting: The default interval time is 00:02 (2 seconds). Press the “Log” key ( 此 K ) for more than 3 seconds and then the interval time will automatically increase. The interval time, loop display, ranges from 00:02 seconds to 60:00 minutes and then back to 00:02 seconds. The interval time ff舌尤 switch 刈 仙他 仞 出 is凹 以 冬 及 刈 凹 仕 以 刈 乍 出 包 controlled by the “Enter” key ( 此 I ); the interval time is 舛尤 刈 仙他 仞 出 凹 以 冬 及 刈 凹 仕 以 刈 乍 出 包 包 以 冊 刈 他 冬 刈 充 付 付 壬 A A Backlight: The backlight appears on the screen during startup and operation. After the device is idle for 30 seconds, the backlight is automatically turned off to extend battery life. A 3) A A No. 5 E CO2 concentration, parts per million (ppm) E A Sensor warm-up time and logging Interval: Measurement: After power on, the device starts to measure and update the data every second. F ) to switch the Zone 1 sensor display. (CO2àCOàO2àAMB) Press the “M1” key ( 此 H ) o switch the Zone 2 sensor display. Press the “M2” key ( 此 (CO2àCOàO2àNH3àRHàDPàAMBàPM2.5àPM10) A Description E Operation Instructions A Zone 1 sensor selection (CO2, CO, O2, AMB) Zone 2 sensor selection (CO2, CO, O2, NH3, RH, DP, AMB, PM2.5, PM10) TWA (CO2, 8-hr time weighted average), STEL (CO2, 15 min. weighted average), MAX, MIN ALTI (Atmospheric pressure) Execute a command or select options. Data logger LCD display symbol description: Symbol A Power on: Switch the Power Key ( 此 A ) on. A. Power Key Key description: F ) M1 ( 此 H ) M2 ( 此 日) 汝 (此 木) 汍 (此 I ) Enter ( 此 K ) Log ( 此 A A A (Display Features and Modes) E Real-time setting: Long press the “M1” key ( 此 F ) to proceed the date and time setting. The default format is 24-hour. Press the “▲( 此 G )/▼( 此 J )” key to edit the parameters, and press the “Enter” key ( 此 I ) to proceed the next setting. The A A E A A E A E A A E A E A A E A Atmospheric pressure compensation: Press and hold the "▼" key ( 此 J ) to turn the compensation function on/off. The gas compensation is only for CO2 and O2. A E A Rechargeable Batteries Buzzer on/off: operation, if AL L or AL H buzzer I ) to turn the buzzer on/off. During Press the “Enter” key ( 此 A sounds, E A Battery message: stops to operate. At this time, press the “Enter” key ( 此 I ) to turn off the buzzer and A E A continue . In addition, the buzzer will be automatically turned off when the data logging interval time is 舛5 minutes. Buzzer AL L/AL H: When AL L is on, the buzzer sounds "Ta Ta Ta"; when AL H is on, the buzzer sounds "Bi Bi Bi". RS485 communications: Please use the 4 Pole 3.5mm headphone plug. The headphone plug contacts are defined as below: 刈 For long-distance communication, it is necessary to use a dedicated isolated line to ensure communication quality. The wiring method is as below:刈 ‘Battery OK’: Measurements are possible ‘Battery Low’: The battery needs to be recharged, measurements are still possible ‘Battery Exhausted’: Measurements are not possible Battery installation: This device is supplied with Li-ion 18650 3.7V rechargeable battery *3 pcs. Please confirm whether batteries + polarity are Li ion18650 positive bump specification and install batteries in the correct polarity. If the battery polarity is reversed, the capacity will be insufficient and the battery life will be shortened. Battery charging: The charge lamp ( 此 E ) lights up while charging; the charge lamp ( 此 E ) goes off when charging is completed. (5V/1A USB adapter charger) Note: During battery charging, the temperature of the device will rise by 5°C~10°C. At this time, the measurements of temperature and humidity will be affected by temperature rise. Cause an impact on the accuracy of temperature when charging, please use a fan to blow toward the temperature sensor (此 C ) directly in order to get a compensated balance of temperature and humidity between temperature sensor and surrounding area. A A E E A A E A A Safety Instructions Power off: Switch the Power Key ( 此 A ) off. Note: When the device is charged with USB, it cannot be turned off. A E A Calibration: (1) Single-point calibration At the same time, long press “▲( 此 G )“ and “▼( 此 J )“ key, CAL is displayed on the screen. Press the “M1” key (此 F ) to select the sensor that needs to be calibrated. Press the “▲( 此 G )/▼( 此 J )” key to edit the parameters, and then press the “Enter” key ( 此 I ) to proceed the next setting. Zone1 displays the unadjusted raw value; Zone2 displays the adjusted value, and it is also the value of returning to the main screen; F ) to return to Zone1-Zone2=adjustment amount. After finishing the setting, press and hold the “M1” key ( 此 the main screen. A A E E A A E A A A A E E A A E A A A E A (2) Two-point calibration At the same time, long press “▲( 此 G )“ and “▼( 此 J )“ key, CAL is displayed on the screen. And then long press the “M2” key ( 此 H ), CAL L is displayed on the screen. Next, press the “M1” key ( 此 F ) to select the sensor that needs to be calibrated (CO2àCOàO2àNH3àPM2.5àRHàAMB) and the corresponding unit will blink. Press "▲( 此 G )/▼( 此 J )" key to adjust the value of the standard gas concentration. Press “Enter“ key (此 I ) to switch CAL H (High gas concentration calibration)/CAL L (low gas concentration calibration). The ppm unit is not flashing for a moment, indicating that the calibration value has been stored. Long press the H ) for a calibration calculation. At the same time, the screen displays the calibration reading to “M2” key ( 此 confirm the accuracy. Short press the “M1” key ( 此 F ) to set the next gas calibration, or long press the “M1” key (此 F ) to return to the main screen. A A A A E E E A E A A A A A E E A A A A E A A A E A E E Warning: Your safety is very important to us. To ensure to use the device correctly and safely, we would like to draw your attention to read the warning and entire User Manual before using the device. These are important safety information and should be observed at all times. 1. Please handle the device lightly, do not subject the device to impact or shock. 2. Do not immerse the device in water. Water can cause electric shock, fire or malfunction which may result in damage. 3. Do not keep the device under the hot and moisture environment. Keep the device away from the heat source or near water. 4. Please use a standard USB power supply (such as PC's USB port, universal AC adapter with USB port). Improper power supply can cause serious damage to the device, or result in injury or death to the user. A Product Care To ensure you receive the maximum benefit from using this device, please observe the follow guidelines. 1. The maximum capacity of the SD card is 16G. 2. During battery charging, the temperature of the device rises. The temperature and humidity sensors are affected. At this time, measurements are only for reference. After batteries are fully charged and the device cools down, measurements are reliable. 3. Repair – Do not attempt to repair the device or modify the circuitry by yourself. Please contact with the local dealer or a qualified repairman if the device needs servicing. 4. Caution – The CO and NH3 sensors must be replaced every 3 years. 5. Cleaning – Disconnect the power before clean. Use a damp cloth, do not use the liquid cleaning agent, such as benzene, thinner or aerosols. 6. Maintenance – Recommend that the user conducts a comprehensive test and calibration every year to ensure the normal operation of the device. Specifications A CO2 刈 Clear Two-point calibration: Set the same calibration value for CAL L and CAL H, and then proceed the calculation. After the calibration is completed, the original calibration value is cleared.刈 CO O2 NH3 PM2.5 PM10 RH Temperature Barometer Operating Conditions Storage Temp. Measurement Range 0~9,999 ppm (5,001~9,999 ppm over range) 0~1,000 ppm 0~25% 0~100 ppm Accuracy ±50 ppm or 5% of reading, whichever is greater (0~5,000ppm) Display Resolution 1 ppm ±5%~±10% 1 ppm <2% FS/0.1 mbar 0.01% ±10% 1 ppm ±15% or ±15 μg/m³, whichever is 999 ug/m3 1 ug/m3 greater 0~100% ±2%@25°C (20% RH~80% RH) 0.01% 0°C~50°C ±1°C 0.01°C 50 ~110 Kpa ±0.4 kpa 0.1 mmHg 0~40°C(32°F~104°F),0~95%RH, non-condensing, with lithium-ion batteries 0~50°C(32~122°F), 0~95%RH, non-condensing, without lithium-ion batteries -20~60°C(-4~140°F), 0~85%RH, non-condensing, without lithium-ion batteries Rechargeable Battery : Li-ion 18650 3.7V *3 (batteries not included) Power Supply AC Adapter : 5V±5% >1A, 100~240 VAC, 50/60 Hz Storage depend on SD card capacity (max.16G SD card) Capacity Comm. RS485 ModBus BR19200劣N劣8劣1 Interface Alarm 80db±5%@10cm Volume Weight 305g (without batteries) Dimension 204.5x91.7x49.6 mm (8.1x3.6x2 inch) EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected. Installation Instruction P ) or hang it on the wall. 1. You can put ZG906CMONP on the table (please pull out the Housing Stand 此 E A A 2. Please note the following when hanging it on the wall. Choose a suitable location to install ZG906CMONP, fix a刈 screw to the wall. Package contents Handheld multi gas detector Manual USB 1.5M cable Radiant Innovation Inc. Http://www.ZyAura.com 1F, No.3, Industrial East 9th Road, Science-Based Industrial Park, HsinChu, Taiwan 300. Ref.No.危102018
advertisement
Key Features
- Simultaneous multi-gas measurement
- Dual-beam NDIR technology for CO2
- Large LCD display
- Data logging with SD card
- RS485 interface for remote monitoring
- Audible alarm
- Li-ion rechargeable batteries
Related manuals
Frequently Answers and Questions
What gases can the ZG906CMONP measure?
The ZG906CMONP can measure CO2, CO, O2, NH3, PM2.5, and PM10 concentrations.
How does the ZG906CMONP store data?
The ZG906CMONP uses an SD card for data logging.
How can I connect the ZG906CMONP to a computer?
The ZG906CMONP has an RS485 interface for connecting to a computer for remote monitoring.