ESI Ergo EDGE2-KIT-WHT Conversion Kit Assembly Guide

Add to My manuals
12 Pages

advertisement

ESI Ergo EDGE2-KIT-WHT Conversion Kit Assembly Guide | Manualzz
EDGE2KIT
DUAL ARM CONVERSION KIT
Model EDGE2KIT-SLV
EDGE2KIT Rev A 2/17
ASSEMBLY AND ADJUSTMENT
EDGE2KIT DUAL ARM CONVERSION KIT
PARTS AND TOOLS
PLEASE REVIEW these instructions before beginning the assembly and adjustment procedures. Check that
all the parts and tools listed below were provided with your order. Contact your supplier if any materials are
missing. Do not discard the packaging until satisfied that the product operates to y
our satisfaction.
With this Edge2Kit, a single arm Edge system is converted to a dual arm system. The monitor arm assembly
from the single arm system is re-used; otherwise, all components are included in the conversion kit.
PARTS AND TOOLS PROVIDED
Base and Monitor Arm Assembly (1)
Clamp Pad (1)
Grommet Mount Plate (1)
Grommet Bar (1)
Grommet Bolt (1)
3x 3/8 -16
Grommet Bolt Washer (1)
Grommet Bolt Nut (2)
9/16 x 3/8 -16
M10x27
VESA Plate Screw (8)
VESA Locking Screw (2)
M4x10
2mm Allen Key (1)
M4x10
4mm Allen Key (1)
ADDITIONAL TOOLS REQUIRED
• Phillips screwdriver
2
14mm Wrench (1)
180° Locking Screw (2)
M4x9
5mm Allen Key (1)
CAUTION: Hand-tighten
screws only. Do not use
power tools.
REMOVAL OF EDGE COMPONENTS
EDGE2KIT DUAL ARM CONVERSION KIT
Disconnect and Remove the Monitor from Edge System Monitor Arm
• Disconnect the monitor cables.
• If a VESA locking screw is installed, remove the screw.
• Press down on the plastic tab on the VESA mount to release the VESA plate.
• Disconnect the monitor cables. Lift the monitor and VESA plate from the VESA mount.
2.
1.
Remove VESA
Locking Screw
Remove the Edge System Monitor Arm
• Loosen the set screw in the base assembly.
• Lift off the monitor arm. Set aside for reinstallation into the dual base assembly.
• Be sure the bushing remains attached to the
monitor arm.
Loosen
Set Screw
3
EDGE2KIT DUAL ARM CONVERSION KIT
INSTALLATION OF EDGE2 BASE ASSEMBLY
Remove the Edge System Base Assembly
• Clamp method. Loosen the clamp knob to remove the
base assembly from the table.
Clamp
Method
• Grommet method. Remove the two nuts securing the
base assembly to the table.
Grommet
Method
IMPORTANT: Recycle the Edge base assembly. Contact
ESI Customer Service at 1-800-833-3746.
Install Edge2 Base Assembly — Clamp Method
With this method, the base assembly is clamped to
a table or desk surface that is between 0.6" (15mm)
thick and 3" (76mm) thick.
The base assembly is shipped with the bottom clamp
in the “upper attachment position.” To change to the
“lower attachment position” for thicker work surface,
follow the procedure described and shown below.
• Use the 4mm Allen key to remove the two screws
holding the bottom clamp in position.
• Reattach the bottom clamp to the lower two holes.
Tighten the screws securely using the Allen wrench.
CAUTION: Do not use a power drill. Clamp screws are
rated at 102 in-lbs.
Upper Attachment
Position (Standard)
0.6" – 2.2"
(15mm – 56mm)
Bottom
Clamp
Assembly
Lower Attachment
Position (Optional)
To Change: 1) Remove
Upper Attachment Screws
2) Re-Install Screws with
Clamp in Lower Position
Remove
1.38" – 3"
(35mm – 76mm)
Bottom
Clamp
Assembly
Re-Install
Upper
Attachment
Lower
Attachment
Attach Clamp Pad
• Peel the backing from the adhesive side of the clamp pad and adhere the pad
to the bottom of the base, as shown. The pad protects the work surface.
Install Base Assembly
• Clamp the base assembly to the work surface. Be sure to tighten the knob
securely.
• Proceed to “Install Second Monitor Arm Assembly” on page 6.
4
Peel and
Adhere
INSTALLATION OF EDGE2 BASE ASSEMBLY
EDGE2KIT DUAL ARM CONVERSION KIT
Install Edge2 Base Assembly — Grommet Method
With this method, the base assembly is secured through a grommet hole in the
work surface, with a diameter between 0.78" (20mm) and 2" (51mm). Surface
thickness must be between 0.6" (15mm) and 1.5" (38.1mm). See page 4.
0.6" – 1.5"
(15mm – 38.1mm)
Remove Clamp Assembly
• Remove the standard clamp assembly from the base
assembly. Use the 4mm Allen key to remove the three
screws holding the clamp assembly in position. Retain
the three screws.
Attach Grommet Assembly
• Place the grommet bolt in the large center hole on
the grommet mount plate.
Remove
Clamp
Assembly
Attach
Grommet
Assembly
• With the grommet bolt in position, fasten the grommet
mount plate and bolt to the monitor arm base with
the three screws previously removed. As before, use
the 4mm Allen key.
Attach Clamp Pad
• Peel the backing from the adhesive side of the clamp pad and adhere the
pad to the bottom of the grommet mount plate, as shown. The pad protects
the work surface.
Peel and
Adhere
Install Base Assembly
• Place the base assembly over the grommet hole, with the bolt centered.
• The bolt must extend under the work surface a minimum of 1.3" (33mm).
Base
Assembly
• Secure the base assembly as illustrated.
— Secure the grommet bar and washer with one of the grommet bolt
nuts. Use the provided wrench to tighten the nut securely.
—
assembly.
• Proceed to “Install Second Monitor Arm Assembly” on page 6.
Washer
Nuts
Grommet
Bar
Wrench
5
EDGE2KIT DUAL ARM CONVERSION KIT
MONITOR INSTALLATION
Install Second Monitor Arm Assembly
• Insert the second monitor arm assembly (from the
original Edge system) into the base assembly.
Second Monitor Arm
(from Edge System)
• Align the metal plate on the monitor arm bushing
with the set screw on the base assembly.
• Secure the monitor arm by tightening the set
screw using the 2mm Allen key. Adjust the
tightness to allow for the desired ease of monitor
arm rotation.
Align
Tighten
Set
Screw
Install Monitors
• Remove the VESA plate from the first monitor arm’s VESA mount
by pressing down on the plastic tab to release the lock. Pull the
plate upward to remove.
• Place the monitor for the first arm face down on
a flat surface. Align the VESA plate holes with the
holes on the back of the monitor. Attach the VESA
plate using the four of the eight VESA plate screws
provided (four screws per monitor).
— There are two sets of four holes on each VESA
plate. One set has holes 3.9" (100mm) apart, the
other set has holes 3" (75mm) apart. Use the set
that matches the holes on the monitor.
• If the monitor from the original Edge system is not
being re-used, remove the VESA plate from that
monitor and attach it to the new one.
6
VESA
Plate
Screw
VESA
Plate
2.
1.
3.9"
(100mm)
VESA Plate
Up
wa
rd
3"
(75mm)
Monitor
(Face Down)
MONITOR INSTALLATION
EDGE2KIT DUAL ARM CONVERSION KIT
• Slide each VESA plate (with monitor attached) onto its VESA mount. Make sure the VESA plate clicks
securely in place.
— Optional: Install a VESA locking screw behind each VESA plate to prevent the tab on the VESA plate
from releasing the monitors.
VESA
Locking
Screw
(Optional)
Cable Management
Use the cable clip and cable cover to help manage the monitor cables.
• Pinch the cable clip to remove it from the motion arm, and again when re-installing it with the cables
captured.
• Slide the cable cover out from the fixed arm. Slide it back in with the cables captured.
Motion
Arm
Fixed
Arm
Cable
Clip
Cable Cover
7
EDGE2KIT DUAL ARM CONVERSION KIT
MONITOR INSTALLATION
Tension Adjustments
There are five possible swivel and tilt tension adjustments for each of the two monitor arms:
1. Monitor swivel adjustment
— Use the 2mm Allen key to adjust the set screw for the desired ease of monitor rotation.
2. Motion arm swivel adjustment
— Use the 2mm Allen key to adjust the set screw for the desired ease of motion arm rotation.
3. Fixed arm swivel adjustment
— Use the 2mm Allen key to adjust the set screw for the desired ease of fixed arm rotation.
4. Monitor tilt adjustment
— Use the 4mm Allen key to adjust the set screw for the appropriate monitor weight.
5. Monitor arm weight adjustment
— Use the 5mm Allen key to adjust the set screw for the appropriate monitor weight.
— Weight capacity per arm is 5.5 lbs to 16.5 lbs (2.5 kg to 7.5 kg). Capacity may be reduced if monitor
size is greater than 26" (66cm) or depth is greater than 2.17" (55mm).
4
5
Tension
Adjustments
Behind
VESA
Plate
1
2
3
8
FINAL ADJUSTMENTS
EDGE2KIT DUAL ARM CONVERSION KIT
180° Lock-Out Feature
• Use the 2mm Allen key to secure the 180° locking screws
into the base of each monitor arm assembly to limit the
fixed monitor arm rotation to 180°. Fully tighten the screws,
then back out one full turn.
180° Locking
Screws
Allen Key Storage
• Insert the Allen keys into the holes behind the VESA plate to
store for future adjustment.
— Insert the two smaller Allen keys into the same hole.
Store
Allen Keys
for Future
Adjustments
9
NOTES
10
800.833.3746
© 2017 ESI Ergonomic Solutions. All rights reserved.
esiergo.com
EDGE2KIT Rev A 2/17

advertisement

Related manuals

advertisement