KERN TORA 3HA-B Operating instructions
PDF
سند
تبلیغات
تبلیغات
3. General information GB Operating manual Analogue refractometer KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Tel: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Betriebsanleitung Analoges Refraktometer KERN ORA 3 HB ORA 6 HB Baumé, Brix, Feuchtigkeit Honig Honig Refraktometer 05 / 2025 KERN ORA 3 HA Baumé, Brix, honey moisture ORA 6 HA Honey refractometer Version 1.3 Version 1.0 12/2014 KERN & Sohn GmbH Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Ziegelei 1 D-72336 Balingen E-Mail: [email protected] 3.1 Intended use ORA_3HB_6HB-BA-d-1410 Contents The refractometer is a measuring instrument for determining the refractive index of transparent substances in the liquid or the solid state. It is used to observe the behaviour of light as it passes from a prism with known properties to the substance being tested. Use of the refractometer for other purposes is contrary to its intended use and may be hazardous. The manufacturer shall not be liable for any damages caused by improper use. 3.2 Warranty The warranty shall be void in the event of: ▸ Failure to observe the instructions in the operating manual ▸ Use for purposes other than those described ▸ Modifications or opening the device housing ▸ Mechanical damage and/or damage resulting from media, liquids, natural wear and tear 4. Basic safety information 1Technical data.................................................................................................1 2 Description......................................................................................................2 3 General information........................................................................................3 3.1 Bestimmungsgemäße Verwendung..............................................................3 3.2 Warranty..........................................................................................................3 4 Basic safety information................................................................................4 4.1 Follow the instructions in the operating manual........................................4 4.2 Warning........................................................................................................ 4-5 5Supplied items.................................................................................................5 6 Before the first use.........................................................................................6 7 Use/measurement.........................................................................................6 7.1 Zero point calibration................................................................................. 7-8 7.2 Additional advice.............................................................................................9 7.3 Measuring procedure............................................................................... 9-10 8 Cleaning and maintenance.......................................................................... 11 9Storage.......................................................................................................... 11 10Service.......................................................................................................... 12 11 Disposal......................................................................................................... 12 12 Additional information................................................................................. 12 13 Brix to refractive index (nD) conversion table.......................................... 13 14 Annex............................................................................................................. 14 4.1 Follow the instructions in the operating manual 1.Technical data ▸ Make sure that you will not be hit by anything else while you are using the refractometer, as this could cause serious eye injuries Models KERN Measuring Scale range and data graduations 1 Technical Scales Accuracy Dimensions Models Measuring Scale gradua-­‐ KERN range Dimensions Product ▸ Every language version includes a non-authoritative translation. The original German document is the definitive version. 4.2 Warning ▸ Do not let acids come into contact with skin or eyes. If acid comes into contact with skin, flush with copious amounts of water. Shower if larger areas of skin are affected. ▸ If acid comes into contact with eyes, keep the eyelid open and flush the eye with running lukewarm water from the outer corner to the inner corner. Flush eyes for at least 15 minutes. Then consult a doctor or ophthalmologist immediately. ▸ Thoroughly clean the refractometer after each use. ▸ The refractometer must not be exposed to extreme temperatures, high mechanical stresses, strong direct sunlight or high humidity. ▸ The rubber eyeshade may cause irritation when in prolonged contact with the skin. If this happens, consult your doctor. Net weight and Accuracy 58-92% Brix Scales 0,5% Brix 0.140kg ORA 3HB 58-­‐92% Brix 0.5% Brix 38-43°Bé 0,5°Bé160x40x40mm 160x40x40mm 38-­‐43°Bé 0.5°Bé 12-­‐27% water 1% w% aterwater 12-27% water 1 168x40x40mm 0.140kg ORA 6HB 12-­‐30% water 0.1% 0,140kg oRA 6 HA oney 12-30% honey tent in h0,1% water content water content inExample honey in honey scale on the ORA 3 HB ▸ Do not touch the lenses with your fingers. 0,140kg Water con-­‐ 168x40x40mm 5. supplied items After unpacking and before using the device for the first time, check that all listed parts have been supplied. Replace damaged or faulty parts immediately and do not put them into operation. Example scale on ORA 3 HA Gerätebeschreibung 3 4 ▸ This refractometer is not a toy. Keep out of reach of children. Net weight oRA 3 HA content in ▸ Carefully read through the operating manual even if you have prior experience with KERN refractometers. Product tions 3 4 1 ▸ Refractometer ▸ Storage box ▸ Pipette ▸ Adjustment tool ▸ Cleaning cloth ▸ Calibration block + Contact liquid (Clove oil) 5 2 2. Description 6. Before the first use 2 Gerätebeschreibung 1 3 2 1 3 5 4 6 1. 2. 3. 4. 5. 6. Prismenabdeckung Prismenfläche Justierschraube Okular mit Gummi-Augenmuschel Einstellring des Diopters 6 Optische Röhre mit Gummigriff 1. 2. 3. 4. 5. 6. 9 Prismenabdeckung Prismenfläche Justierschraube 8 Okular mit Gummi-Augenmuschel Einstellring des Diopters Optische Röhre mit Gummigriff 5 10 11 9 7 12 8 7. Aufbewahrungsbox 8. Pipette 10 ORA_3HB_6HB-BA-e-1510 1. 2. 3. 4. 5. 6. Prism cover Prism surface Adjustment screw Eyepiece with rubber eyeshade Diopter adjustment ring Optical tubes with rubber grip 7. Storage box 8. Pipette 9. Refractometer 10. Contact liquid (Clove oil) 11. Adjustment tool 12. Cleaning cloth Remove the protective film (if present) from the prism surface [2] and check that the rubber eye-cup [4] is fitted correctly. 7. Use/measurement The refractometer can be used to quickly and accurately determine the refractive index of transparent substances, liquid or solid ones. To ensure correct measurement, the measuring device should be adjusted before measurements are carried out. Please make sure your hands are dry before handling the measuring device. Important! 2 ! Avoid bringing the supplied contact liquid (clove oil) into contact with the prism cover [1]. Even the smallest amounts of clove oil will damage the material of the cover and lead to its opacification. Therefore, pay big attention to this aspect while carrying out the adjustment of the refractometer described below. If still there is accidentally contact between clove oil and the prism cover, it would not affect subsequent measurement operations even when high opacification occurs. 6 7.1 Zero point calibration 8. Cleaning and maintenance ▸ Hold up the refractometer against a sufficiently bright light source and look through the eyepiece [5], holding the rubber eyeshade [4] closely against your eye/glasses. ▸ Rotate the eyepiece [5] to adjust it for your eyesight, until you can see the scale sharply. ▸ Open the prism cover [1]. ▸ Thoroughly clean the prism [2] and the underside of the prism cover [1] using a soft cloth or soft paper (with alcohol if necessary) and wipe dry. ▸ Moisten the polished surface of the calibration block with the contact fluid. Now put the block with the moistened surface downward onto the prism surface [2]. ▸ Close the prism cover [1]. The amount of fluid should be sufficient to moisten most of the block surface. There should not be any air bubbles between the measuring prism [2] and calibration block. ▸ Wait about 30 seconds to allow the temperatures of the fluid and prism to equalise. ▸ Look through the eyepiece [4] while pointing the refractometer‘s prism surface [2] at a bright light source. ▸ Through the eyepiece [4], you will see a bright and a blue field. The boundary line between them shows the measured value on the scale which is also visible 7 through the eyepiece [4]. Clean the refractometer using a soft, lint-free cloth moistened with either water or, if necessary, alcohol. Do not use any aggressive or abrasive cleaning agents. Never immerse the device in water or hold it under running water. Never handle the device with wet or damp hands. Never touch the measuring prism [2] with hard tools made from plastic, wood, rubber, metal, glass etc. Hard objects can quickly damage the relatively soft prism glass, resulting in measurement errors. The refractometer is maintenance-free. Cleaning should be carried out immediately before and after each use of the refractometer to maximise its life and optimise measurement results. 9.Storage Store the refractometer in a dry, non-corrosive environment, preferably between 10 °C and 30 °C. 10.Service ▸ Use the supplied adjustment tool [11] to turn the adjustment screw [3] behind the prism surface [2] (under the rubber cap), and adjust the scale so that the measuring device is optimally set up by moving the boundary line upwards or downwards. Calibration value ORA 3HA: 78.8 % (Brix) (See the calibration line in the scale) Calibration value ORA 3HA: 19,6 % (Water content) (See the calibration line in the scale) After reading this operating manual, if you have any questions about setting up or using the refractometer, or if any unexpected problem occurs, please contact your dealer. The device housing may only be opened by trained service technicians authorised by KERN. ▸ Repeat step 4 (cleaning). 11. Disposal The packaging consists of environmentally friendly materials which can be disposed of via local recycling facilities. The device and storage box should be disposed of by the operator in accordance with applicable national or regional regulations at the place of use. ! The ambient/room temperature and the sample temperature influ-ence the refractometer measuring result. The scales of the refractometer models, which have "HB" in its name, are designed for an ambient temperature of +20 °C! If the measurements are carried out at a temperature other than +20 °C, the results must be correspondingly corrected. A correction table can be found in the annex, Point 14. Refractometer models, which have "HA" in its name, are equipped with an automatic temperature compensation (ATC). Between +10°C and +30°C measurement differences due to temperature changes are automatically compensated. 12. Additional information The product may differ slightly from the illustrations. Avoid exposing the refractometer to direct sunlight. Never bring the refractometer into contact with solvents. 13. Brix to refractive index (nD) conversion table After every measurement, use a lint-free, absorbent cloth to remove the fluids from the prism surface [2] and prism cover [1]. Then carefully clean the prism and prism cover using a cloth moistened with water or if necessary alcohol, and dry both parts using a soft, dry and lint-free cloth. Avoid rubbing the prism [2]. ! 10 1.50398 1.43967 1.37758 1.37936 28 29 59 1.37582 27 58 1.43743 85 1.43520 1.43299 1.43080 1.37406 26 57 1.37233 25 56 1.37060 55 1.49862 1.50129 84 1.42862 1.49597 24 54 83 82 1.42432 1.42647 53 52 1.36720 1.36889 23 1.36551 21 22 1.4881 1.49071 1.49333 81 1.42220 1.48552 1.36384 20 51 79 80 1.42009 1.41799 1.36218 19 50 1.48295 1.36054 18 49 78 1.41592 1.48040 1.35891 17 48 77 1.41385 1.47787 1.35729 16 47 76 1.41181 1.47535 1.35568 15 46 75 1.40978 1.47285 1.47037 1.35408 14 45 74 1.40776 1.46792 1.35250 13 44 72 71 73 1.40576 1.40378 1.40181 1.35093 12 43 1.34937 11 42 1.34782 10 41 1.46303 1.46546 70 1.39986 1.46061 1.34629 9 40 69 1.39792 1.45822 1.34476 8 39 68 1.39600 1.45584 1.45348 1.34325 7 38 67 1.39409 1.45113 1.34175 6 37 65 66 1.39220 1.39032 1.34026 5 36 1.33879 4 35 1.44881 63 64 1.38846 1.38661 1.33732 3 34 1.33586 2 33 1.44650 1.44420 61 62 1.38478 1.38296 1.33442 1 31 nD 1.33299 32 60 1.38115 % 0 30 Refractive index nD BRIX Refractive index 12 13 14. Annex Table 1: International Temperature Correction Table for °Brix (% sugar gradient) 14Correct Annex the result by the following values (refractometer must be correctly Table 1: International Temperature Correction Table for °Brix (% sugar gradient) adjusted at 20 °C). Correct the result by the following values (refractometer must be correctly adjusted at 20 °C) Temperature °C Important! BRIX Refractive index ▸ The boundary line will move on the measurement scale depending on the concen- 9 tration. This bright/dark boundary line shows the result on the scale. ▸ If the temperature deviates from +20 °C and a refractometer without ATC is used, correct the measured result using the corresponding value from the temperature correction table [13]. ▸ Carefully clean the supplied pipette [8] and the refractometer after carrying out the measurement. % ▸ Make sure your hands are dry before handling the refractometer. ▸ Open the prism cover [1] and use the supplied pipette [8] to apply a few drops of the sample liquid [8] onto the prism surface [2]. Close the prism cover [1]. Spread the liquid evenly by pressing down on the prism cover [1] and elimi-nate any air bubbles present.⇨ ▸ Hold the device horizontally and wait about 30 seconds (for optimal tempera-ture equalisation between the sample and device). ▸ View the measurement scale through the eyepiece [4]. Point the prism surface [2] of the refractometer at a bright light source while doing this. ▸ Rotate the adjustment ring [5] on the eyepiece [4] to adjust the focus. BRIX 7.3 Measuring procedure 13 Brix to refractive index (nD) conversion table It is important that the samples being measured are representative samples. For samples that evaporate easily, measurements should be carried out quickly. The samples should be at the same temperature as the measuring instrument in order to achieve an accurate result. nD 7.2 Additional advice 1.44193 Data from „ICUMSA“ International Commission for Uniform Methods of Sugar Analysis, at 20 °C and 589 nm wavelength. 8 % Important! 11 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0 21.0 22.0 23.0 24.0 25.0 26.0 27.0 28.0 29.0 30.0 % Brix reading 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 65.0 70.0 75.0 80.0 85.0 -0.53 -0.56 -0.59 -0.62 -0.65 -0.67 -0.69 -0.71 -0.72 -0.73 -0.74 -0.75 -0.75 -0.75 -0.75 -0.74 -0.49 -0.52 -0.54 -0.57 -0.59 -0.61 -0.63 -0.64 -0.65 -0.66 -0.67 -0.68 -0.68 -0.68 -0.68 -0.67 -0.67 -0.66 -0.44 -0.47 -0.49 -0.51 -0.53 -0.55 -0.56 -0.57 -0.58 -0.59 -0.60 -0.60 -0.61 -0.61 -0.60 -0.60 -0.60 -0.59 -0.40 -0.41 -0.43 -0.45 -0.47 -0.48 -0.50 -0.51 -0.52 -0.52 -0.53 -0.53 -0.53 -0.53 -0.53 -0.53 -0.52 -0.52 -0.34 -0.36 -0.38 -0.39 -0.40 -0.42 -0.43 -0.44 -0.44 -0.45 -0.45 -0.46 -0.46 -0.46 -0.46 -0.45 -0.45 -0.44 -0.29 -0.31 -0.32 -0.33 -0.34 -0.35 -0.36 -0.37 -0.37 -0.38 -0.38 -0.38 -0.38 -0.38 -0.38 -0.38 -0.37 -0.37 -0.24 -0.25 -0.26 -0.27 -0.28 -0.28 -0.29 -0.30 -0.30 -0.30 -0.31 -0.31 -0.31 -0.31 -0.31 -0.30 -0.30 -0.30 -0.18 -0.19 -0.20 -0.20 -0.21 -0.21 -0.22 -0.22 -0.23 -0.23 -0.23 -0.23 -0.23 -0.23 -0.23 -0.23 -0.23 -0.22 -0.12 -0.13 -0.13 -0.14 -0.14 -0.14 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.06 -0.06 -0.07 -0.07 -0.07 -0.07 -0.07 -0.08 -0.08 -0.08 -0.08 -0.08 -0.08 -0.08 -0.08 -0.08 -0.08 -0.07 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.07 0.07 0.07 0.07 0.07 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.07 0.13 0.14 0.14 0.14 0.15 0.15 0.15 0.15 0.16 0.16 0.16 0.16 0.16 0.16 0.15 0.15 0.15 0.15 0.20 0.21 0.21 0.22 0.22 0.23 0.23 0.23 0.23 0.24 0.24 0.24 0.24 0.23 0.23 0.23 0.23 0.22 0.27 0.28 0.29 0.29 0.30 0.30 0.31 0.31 0.31 0.32 0.32 0.32 0.32 0.31 0.31 0.31 0.30 0.30 0.34 0.35 0.36 0.37 0.38 0.38 0.39 0.39 0.40 0.40 0.40 0.40 0.40 0.39 0.39 0.39 0.38 0.37 0.42 0.43 0.44 0.45 0.46 0.46 0.47 0.47 0.48 0.48 0.48 0.48 0.48 0.47 0.47 0.46 0.46 0.46 0.50 0.51 0.52 0.53 0.54 0.55 0.55 0.56 0.56 0.56 0.56 0.56 0.56 0.55 0.55 0.54 0.53 0.52 0.58 0.59 0.60 0.61 0.62 0.63 0.64 0.64 0.64 0.65 0.65 0.64 0.64 0.64 0.63 0.62 0.61 0.60 0.66 0.67 0.68 0.69 0.70 0.71 0.72 0.73 0.73 0.73 0.73 0.73 0.72 0.72 0.71 0.70 0.69 0.68 0.74 0.75 0.77 0.78 0.79 0.80 0.81 0.81 0.81 0.82 0.81 0.81 0.81 0.80 0.79 0.78 0.77 0.75 -0.75 -0.73 14 ">
/
دانلود
فقط یک یادآوری دوستانه. می توانید سند را درست در اینجا مشاهده کنید. اما مهمتر از همه، هوش مصنوعی ما قبلاً آن را خوانده است. این می تواند موارد پیچیده را به زبان ساده توضیح دهد، به سوالات شما به هر زبانی پاسخ دهد و به شما کمک کند به سرعت حتی طولانی ترین یا پیچیده ترین اسناد را پیمایش کنید.
تبلیغات