Visit website for
available languages of
this document.
Unidirectional activation sensor for
automatic, pedestrian doors
ENGLISH
EAGLE
3
4
1
2
5
1.
main connector
2.
wide zone antenna
3.
narrow zone antenna
4.
push buttons
5.
cover
75.5601.04 EAGLE 20240412
Page 1 of 8
TECHNICAL SPECIFICATIONS
Technology:
microwave and microprocessor
Transmitter frequency:
24.150 GHz
Transmitter radiated power:
< 20 dBm EIRP
Transmitter power density:
< 5 mW/cm²
Detection mode:
motion
Min. detection speed:
2 in/s
Supply voltage:
12 – 24 VAC ±10%; 12 – 24 VDC +30% / -10%
Mains frequency:
50 – 60 Hz
Max power consumption:
<2W
Output:
max. contact voltage:
max. contact current:
max. switching power:
relay (free of potential changeover contact)
42V AC/DC
1A (resistive)
30W (DC) / 60VA (AC)
Mounting height:
6’ – 13’
Degree of protection:
IP54
Temperature range:
-4 – 131 °F
Dimensions:
4.7" (L) × 3.1" (H) × 2.0" (W)
Tilt angles:
0 – 90° vertical; -30 – 30° lateral
Material:
ABS
Weight:
7.6 oz
Cable length:
8’
Norm conformity:
R&TTE 1999/5/EC, LVD 2006/95/EC, RoHS 2 2011/65/EU
Specifications are subject to change without prior notice.
All values measured in specific conditions.
INSTALLATION TIPS
• Do not touch electrical parts.
• Avoid vibrations.
• Do not cover the sensor.
• Avoid proximity to neon lamps or moving objects.
• The sensor may be mounted horizontally or vertically (e.g. on a ceiling or on a wall, respectively).
◊ If mounting horizontally, the sensor must be mounted in front of the door.
◊ If mounting vertically, the sensor must be mounted above the door.
How to Open the Sensor:
BEFORE MOUNTING
Page 2 of 8
AFTER MOUNTING
75.5601.04 EAGLE 20240412
MOUNTING & WIRING
If using EAGLE SPACER or EAGLE SPACER V, please refer to User’s Guide 75.5981 before beginning.
1
Apply the mounting template.
Drill 1 hole for the cable and pull it through.
Drill 2 holes for the screws.
2
Connect the wires accordingly:
1: RED - POWER SUPPLY (+)
2: BLACK - POWER SUPPLY (-)
3: WHITE - COM
4: GREEN - NO OR 5: GREEN - NC
3
Position the cable as indicated.
Mount the sensor firmly.
75.5601.04 EAGLE 20240412
Page 3 of 8
MECHANICAL ADJUSTMENTS
4
Choose the appropriate antenna (narrow or wide) for the correct
detection zone width.
Narrow: 6’ 6" × 8’
Wide: 13’ × 6’ 6"
See diagram (right) for how to change antennas.
WIDE
NARROW
7 ft
7 ft
ZONE SIZE: XXL
IMMUNITY: normal
5
ZONE SIZE: XXL
IMMUNITY: normal
If desired, adjust the antenna angle (laterally and/or vertically) to position the detection field.
When mounting at the maximum height, the sensor manufacturer recommends a 15° tilt angle.
Observe antenna type (narrow or wide) in the illustrations below.
LATERAL ADJUSTMENT
WIDE
NARROW
10 ft
7 ft
VERTICAL ADJUSTMENT
WIDE
NARROW
7 ft
Page 4 of 8
10 ft
75.5601.04 EAGLE 20240412
SETTINGS
6
Program the sensor for the desired application, using the remote control or push button options.
When mounting at the maximum height, the sensor manufacturer recommends the following:
Immunity = low
Zone Size = XXL
REMOTE CONTROL
FACTORY VALUES
XXS
ZONE SIZE
IMMUNITY FILTER
XS
S
>
>
>
low
normal
high
>
>
DETECTION MODE
bi
uni
OUTPUT
CONFIGURATION
A
P
1.5 s
3s
MOUNTING HEIGHT
< 10 ft
> 10 ft
DOOR CONTROL
auto
open
HOLD-OPEN TIME
0.5 s
uni
MTF
uni
AWAY
MTF &
AWAY
>
L
XL
XXL
>
L
XL
highest
bi = two-way detection
uni = one-way detection towards sensor
uni MTF = one-way detection with motion tracking feature
uni AWAY = one-way detection away from sensor
A = active output (NO-contact); relay energizes upon detection
P = passive output (NC-contact); relay de-energizes upon detection
5s
closed
7s
9s
10 s
15 s
20 s
30 s
open = the sensor detects constantly. The LED is ON.
closed = the sensor is in standby and does not detect. The LED is OFF.
FACTORY RESET
reset
ACCESS CODE
Access codes (1 to 4 digits) are recommended to set sensors installed close to each other.
SAVING ACCESS CODE:
DELETE ACCESS CODE:
Once you have saved an access code, you always need to enter this code to unlock the sensor.
If you forget the access code, cycle the power. For the first minute, you can access the sensor without an
access code.
PUSH BUTTONS
ZONE SIZE
FACTORY RESET
> 2 sec +
75.5601.04 EAGLE 20240412
Page 5 of 8
TROUBLESHOOTING
The door remains closed.
LED is off.
Sensor power is off.
Check wiring and power supply.
Door control setting (F2) is set
to 3 (closed).
Change door control setting (F2) to 1
(automatic).
Door does not react as
expected
Improper output configuration
on sensor.
Change the output configuration setting
on each sensor connected to the door
operator.
Door opens and closes
constantly
Sensor is disturbed by door
motion or vibrations from door
motion.
Ensure sensor is fixed properly.
Ensure detection mode is unidirectional.
Increase antenna angle.
Increase immunity filter.
Reduce zone size.
Door opens for no
discernable reason
It rains and the sensor detects
the motion of the rain drops.
Ensure detection mode is unidirectional.
Increase immunity filter.
Install rain accessory.
In highly reflective
environments, the sensor
detects objects outside of its
detection zone.
Change the antenna angle.
Reduce zone size.
Increase immunity filter.
In airlock vestibules, the sensor
detects the movement of the
opposite door.
Change the antenna angle.
Change antenna.
Increase immunity filter.
LED flashes quickly after
unlocking
Sensor needs access code to
unlock.
Enter correct access code.
If you forgot the code, cycle the power to
access the sensor without access code.
Change or delete the access code.
Sensor does not respond
to the remote control
Page 6 of 8
Batteries in the remote
control are weak or installed
improperly.
Check batteries and change if necessary.
Remote control not pointed
correctly.
Point remote control at sensor.
75.5601.04 EAGLE 20240412
NOTES
75.5601.04 EAGLE 20240412
Page 7 of 8
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device;
therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for
doors/gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring
that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s
recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must
be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g.
ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).
©BEA | Original Instructions | PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOR PRINTING
Verify that all appropriate industry signage, warning labels, and placards are in place.
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
General Tech Questions: [email protected] | www.BEAsensors.com
Page 8 of 8
75.5601.04 EAGLE 20240412
">