BEA EAGLE Original Instructions
BEA Eagle is a versatile sensor for automatic doors, offering customizable settings and reliable operation. With microwave and microprocessor technology, it detects motion with high precision and can be configured for one-way or two-way detection. Installation is simplified with clear markings and a range of mounting options. The Eagle's immunity filter and adjustable detection zone size ensure optimal performance in various environments.
Advertisement
Advertisement
DESCRIPTION
1
EAGLE & EAGLE HM
Unidirectional activation sensor for automatic, pedestrian doors and high-mount doors
3
4
2
5
1. main connector
2. wide zone antenna (Eagle only)
3. narrow zone antenna (optional for Eagle, default for Eagle HM)
4. push buttons
5. cover The image shown here is a standard Eagle.
Antennae differ between the standard and high-mount versions of the Eagle.
TECHNICAL SPECIFICATIONS
Technology:
Transmitter frequency:
Transmitter radiated power:
Transmitter power density:
Detection mode:
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output: max. contact voltage: max. contact current: max. switching power:
Mounting height:
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable length:
Norm conformity: microwave and microprocessor
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm² motion
2 in/s
12 – 24 VAC ±10%; 12 – 24 VDC +30% / -10%
50 – 60 Hz
< 2 W relay (free of potential changeover contact)
42V AC/DC
1A (resistive)
30W (DC) / 60VA (AC)
Eagle: 6’ – 13’
Eagle HM: 10’ − 16’6"
IP54
-4 – 131 °F
4.7" (L) × 3.1" (H) × 2.0" (W)
0 – 90° vertical; -30 – 30° lateral
ABS
7.6 oz
Eagle: 8’
Eagle HM: 30’
R&TTE 1999/5/EC, LVD 2006/95/EC, RoHS 2 2011/65/EU
Specifications are subject to change without prior notice.
All values measured in specific conditions.
75.5957.01 EAGLE FAMILY 20180508 Page 1 of 4
OPENING THE SENSOR
BEFORE
MOUNTING
MOUNTING & WIRING
AFTER
MOUNTING
Do not touch electrical parts.
Avoid vibrations.
1
Header mounting above sliding, revolving, or swing door
2
Do not cover the sensor.
Avoid proximity to neon lamps or moving objects.
3
Ceiling mounting in front of door (sliding, revolving, or swing doors)
Apply the mounting template.
Drill 1 hole for the cable and pull it through.
Drill 2 holes for the screws.
Connect the wires accordingly:
1 - RED - POWER SUPPLY +
2 - BLACK - POWER SUPPLY -
3 - WHITE - COM
4 - GREEN - NO
5 - GREEN - NC or
MECHANICAL ADJUSTMENTS
WIDTH (standard Eagle only)
Position the cable as indicated.
Mount the sensor firmly.
7 ft 7 ft
Page 2 of 4
13’ × 6’ 6" (wide) 6’ 6" × 8’ (narrow)
75.5957.01 EAGLE FAMILY 20180508
MECHANICAL ADJUSTMENTS
ANGLE (standard Eagle)
7 ft 7 ft
Adjust the lateral antenna angle.
ANGLE (high-mount Eagle)
10 ft
Adjust the vertical antenna angle.
10 ft
Adjust the lateral antenna angle.
Adjust the vertical antenna angle.
When mounting at the maximum height, BEA recommends a 15° tilt angle.
SETTINGS (by remote control or push buttons)
ZONE SIZE XXS XS S > > > > L XL XXL
IMMUNITY FILTER
DETECTION MODE low bi
A normal high uni
P uni
MTF
> uni
AWAY
> > L XL highest
MTF &
AWAY bi = two-way detection uni = one-way detection towards sensor uni MTF = one-way detection with motion tracking feature uni AWAY = one-way detection away from sensor
A = active output (NO-contact); relay energizes upon detection
P = passive output (NC-contact); relay de-energizes upon detection
OUTPUT
CONFIGURATION
HOLD-OPEN TIME 0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s
MOUNTING
HEIGHT
< 10 ft > 10 ft
Standard Eagle default = < 10 ft
High-mount Eagle default = > 10 ft
DOOR CONTROL auto open closed open = the sensor detects constantly. The LED is ON.
closed = the sensor is in standby and does not detect. The LED is OFF.
When mounting at the maximum height, BEA recommends the following:
Immunity = low
Zone Size = XXL
FACTORY VALUES
RESETTING TO FACTORY VALUES: OR +
> 2 sec
ZONE SIZE
... S, XS ,
XXS ...
L
,
XL
,
XXL
75.5957.01 EAGLE FAMILY 20180508 Page 3 of 4
ACCESS CODE
The access code (1 to 4 digits) is recommended to set sensors installed close to each other.
SAVING AN ACCESS CODE:
DELETING AN ACCESS CODE:
Once you have saved an access code, you always need to enter this code to unlock the sensor.
If you forget the access code, cycle the power . For the first minute, you can access the sensor without an access code.
TROUBLESHOOTING
The door remains closed.
LED is off.
Door does not react as expected
Door opens and closes constantly
Door opens for no discernable reason
LED flashes quickly after unlocking
Sensor does not respond to the remote control
Sensor power is off.
Door control setting (F2) is set to
3 (closed).
Improper output configuration on sensor.
Sensor is disturbed by door motion or vibrations from door motion.
It rains and the sensor detects the motion of the rain drops.
In highly reflective environments, the sensor detects objects outside of its detection zone.
In airlock vestibules, the sensor detects the movement of the opposite door.
Sensor needs access code to unlock.
Batteries in the remote control are weak or installed improperly.
Remote control not pointed correctly.
Check wiring and power supply.
Change door control setting (F2) to 1
(automatic).
Change the output configuration setting on each sensor connected to the door operator.
Ensure sensor is fixed properly.
Ensure detection mode is unidirectional.
Increase antenna angle.
Increase immunity filter.
Reduce zone size.
Ensure detection mode is unidirectional.
Increase immunity filter.
Install rain accessory.
Change the antenna angle.
Reduce zone size.
Increase immunity filter.
Change the antenna angle.
Change antenna.
Increase immunity filter.
Enter correct access code.
If you forgot the code, cycle the power to access the sensor without access code.
Change or delete the access code.
Check batteries and change if necessary.
Point remote control at sensor.
BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factorytrained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL 325).
Verify that all appropriate industry signage and warning labels are in place.
Page 4 of 4
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
General Tech Questions: [email protected] | Tech Docs: www.BEAinc.com
75.5957.01 EAGLE FAMILY 20180508
Download