SAJ PDM30 Smart Mini Pump Drive User Manual
PDF
દસ્તાવેજ
જાહેરાત
જાહેરાત
PDM30 Smart Mini Pump Drive User Manual Version Code :6.0004.0544-00-PDM30-E-V02-2110 PDM30 Series Preface Thank you for using PDM30 series products. This manual provides you with relevant operation instructions and detailed description of parameters. Please read this manual carefully before installation, running, maintenance or inspection. Please make sure the wiring and the pump’s rotation direction is correct before use. - 1 - PDM30 Series CONTENTS Preface.................................................................................................... - 1 Notes for Safe Operation.......................................................................- 4 Chapter 1 Operation Panel...................................................................- 8 1.1 Operation Panel Diagram.............................................................. - 8 1.3 Operation and display mode..........................................................- 9 1.4 Menu Operation.............................................................................- 9 Chapter 2 Appearance and Wiring.................................................... - 12 2.1 Model Description.......................................................................- 12 2.2 Selection table............................................................................. - 12 2.3Dimensions...................................................................................- 13 2.4Installation Procedure Illustrations...............................................- 13 2.5Wiring Diagram of Main Circuit and Control Terminals............. - 15 2.6Control Terminals.........................................................................- 15 2.7 Wiring of Sensors........................................................................ - 16 Chapter 3 Quick Start.........................................................................- 18 3.1 Parameter Settings.......................................................................- 18 Chapter 4 Programming and Parameters......................................- 20 - 4.1Pressure and Protection Function Group......................................- 20 4.4 Frequency and Auxiliary Function Group...................................- 26 4.5 Parameter Setting Procedure....................................................... - 31 4.6 Programming Description of Parameters.................................... - 33 - - 2 - PDM30 Series Chapter 5 Fault Information and Troubleshooting..........................- 44 5.1 Fault Codes Description.............................................................. - 44 5.2 Common Faults and Actions....................................................... - 50 Chapter 6 Warranty Policy.................................................................- 52 Product warranty Card...................................................................... - 54 - - 3 - PDM30 Series Notes for Safe Operation Read this instruction manual thoroughly before installation, operation, maintenance or inspection of the smart pump drive. In this manual, safe operation are classified as “WARNING” or “CAUTION”. SPD: Abbreviation of smart pump drive. WARNING Indicate a potentially dangerous situation which, if not avoided, could result in death or serious injury to personnel. CAUTION Indicate a potentially dangerous situation which, if not avoided, could result in minor or moderate injury and damage to equipment. It may also be used for warning against unsafe practices. Even items described as ( CAUTION) may result in a vital accident in some situations. Please follow these important notes: Before Installation WARNING Do not install or operate any SPD that is damaged or has missing parts. Otherwise, it may result in equipment damage or harm life. - 4 - PDM30 Series Installation Hold the bottom of the SPD when install or move the SPD, cannot just hold the shell to prevent the injured or broken SPD. SPD must be far away from heat source, flammable and explosive objects, and installed on metal or other nonflammable objects. If the SPD is mounted in a protective cabinet, the cabinet need to set vents to ensure ambient temperature is below 40℃; otherwise it may be damaged because of high temperature. Wiring Ensure only qualified personnel to operate. Otherwise it can cause an electrical shock or damage of the SPD. Make sure the SPD is isolated from power supply by the circuit breaker. Otherwise it may cause a fire. Make sure that the ground terminal electrical shock. is grounded correctly. Otherwise it can cause an Please do not touch the main circuit terminal, and the main circuit terminals of the SPD do not contact the shell. Otherwise it may cause an electrical shock. Before connecting, make sure that the SPD rated voltage, phase number confirm to input voltage, phase number; Otherwise it may cause fire or personal injury. Never connect the AC input power supply to output terminals V, U, W; Otherwise the SPD will be damaged and the guarantee is invalid. Never perform with stand voltage test of the SPD, otherwise it may cause a damage to the SPD. The main circuit wiring of the SPD and the control loop wiring should be separated or - 5 - PDM30 Series vertical crossed, otherwise it will make the control signal interference. The cable connected to the main circuit terminals should be use lugswith isolated casing. If the length of cable between the SPD and the motor is more than 50 meters, it is recommended touse a output reactor to protect the SPD and motor. Run Turn on the input AC power only after the front cover is put correctly; Do not open or remove the front cover when operation. Otherwise it may cause an electric shock. If the function fault automatic reset or restart after power failure had been set, a safety measures should be taken in advance; otherwise it may cause damage or injury. The key “RUN/STOP” may be lose efficacy because some function had been set, a separate emergency power switch can be installed in the SPD control system; otherwise it may cause damage or injury. When the SPD is power on, the SPD terminal is still live even in stop state, do not touch, otherwise there is a risk of electric shock. Do not use circuit breaker to control the stop or start of the SPD; Otherwise it may cause damage to the SPD. Because the SPD speed from low to high that is in a very short time, make sure that the motor and equipment are in the permitted range to use. Otherwise it may cause damage to the equipment. Do not touch the heat sink. Otherwise it may cause harmful burns The factory parameters of the SPD can meet most requirements of equipment operation, if not necessary, please do not modify the parameters. Even though some equipment has special needs, only necessary parameters can be modified. Otherwise, random modifications may cause damage to the device. - 6 - PDM30 Series Maintenance and check When power on, do not touch the connection terminals. Otherwise it may cause an electrical shock. Only qualified electrical engineering personnel can maintain, replace and inspect the SPD. Wait at least 10 minutes after the power failure, or make sure that is no residual voltage before carry out maintenance and inspection, otherwise it may cause damage. PCB board has CMOS integrated circuit, do not touch, otherwise the static electricity may damage PCB board. Others It is strictly forbidden to transform the SPD, otherwise it may cause casualties. After arbitrarily changing SPD, the guarantee will be invalid. - 7 - PDM30 Series Chapter 1 Operation Panel 1.1 Operation Panel Diagram Target pressure Name "MENU" button "RUN / STOP" button "UP" button "DOWN" button "Target pressure" Indicator "Current pressure" Indicator Current pressure Definition and operating instructions Click on the 0 level menu to view the role of the parameter for shifting, long press 2S to enter the 1 level parameter setting menu; Click run / stop / reset in level 0 menu; click confirm in 1/2/3 / level password input menu; Click the 0 level menu to increase the set pressure, frequency, modify the parameter value, long press to increase quickly; Click the 0 level menu to decrease the set pressure, frequency, modify the parameter value, long press to quickly decrease; When the display shows "target pressure" and "current pressure", it lights up when the pressure is adjusted; When the display is "target pressure" and "current pressure" light up; "Running" lights Always on during operation, blinking during sleep, and extinguished when stop fault; "Alarm" indicator Blinks during faults and goes off when it is not in a fault state; "Manual" indicator When P0-44 = 1 speed control mode, the indicator light is on, other modes are off; - 8 - PDM30 Series 1.3 Operation and display mode (1) Status display mode: When power on the SPD, it enters the status display mode. When it stops, it displays pressure setting. Press "+" or "-"to modify pressure setting. When it is running,it displays current pressure, operating frequency, and setting pressure. Press the "+" or "-" to switch the display; press "MENU" for two seconds to enter the parameter setting mode. (2) Parameter setting mode: To view or set the parameters, as starting from status display mode, press the "MENU" for 2 seconds to enter the parameter setting mode, and then press the "RUN / STOP" starts to set parameters. After you set the parameter press twice "MENU" to exit parameter setting mode, and return to the status display mode. (3) The alarm display mode: Automatically enter this mode when a drive fault or warning arises; press the "RUN / STOP" to reset, or it can automatically restored the previous mode after the alarm is eliminated. 1.4 Menu Operation Three-class menus are: ① Function group (first class) ② Function code setting(second class) ③Function code setting(third class) - 9 - PDM30 Series Instruction: In the third class menu, pressing “MENU” or “RUN/STOP” can return to the second class menu. The difference is that pressing “RUN/STOP” first saves parameters to control board, and then returns to the second class menu and shifts to next function code automatically; pressing “MENU” returns to the second class menu directly without saving parameters and keeps staying at current function code. Under the third class menu, only flicker bit can be modified. Revisable bit will shift automatically after 5 seconds. Note: For parameters marked with “●”, please modify them in stopped state. Parameters marked with “◎” are actual detected and recorded values which can’t be modified. - 10 - PDM30 Series Example: Modify P0.02 from 0 to 1 Remarks: 0.1MPa = 100kPa = 1bar = 1kgf / cm2 - 11 - PDM30 Series Chapter 2 Appearance and Wiring 2.1 Model Description 2.2 Selection table Voltage 220V Single entry Three out Size(mm) Model Power (kW) H W D Motor (kW) PDM30-2SR75-E 0.75 210 146 121 0.75 PDM30-2S1R5-E 1.5 210 146 121 1.5 PDM30-2S2R2-E 2.2 210 146 121 2.2 - 12 - Explanation The factory default is 2.2kW, which can be adjusted by P1-12, 0 = 0.75kW 1 = 1.5kW 2 = 2.2kW PDM30 Series 2.3Dimensions (Unit: mm) 2.4Installation Procedure Illustrations. Step 1: Remove the bottom plate Step 2: Install the bottom plate - 13 - PDM30 Series Step 3:Install the bottom plate Step 4: The installation is complet - 14 - PDM30 Series 2.5Wiring Diagram of Main Circuit and Control Terminals 2.6Control Terminals 2.6.1 Control terminals The wiring mode of control terminals is internal terminal wiring or outer lead connection, cabled-out by waterproof connectors. S+ S- DI1 DI2 GND Control terminals - 15 - AI VO PDM30 Series 2.6.2 Terminal instruction Terminal symbol Terminal name Technical data DI1 Multi-function input terminal 1 Enabled when connected to GND; Disabled when open DI2 Multi-function input terminal 2 Enabled when connected to GND; Disabled when open AI Analog input terminal 1 It is 0 ~ 10V analog voltage input terminal or 4-20mA analog current input terminal, chosen by function codes. VO Positive terminal +5V~+24V adjustable power; Output voltage value is set of analog power by function codes. GND Negative terminal Reference zero potential of +5V~+24V adjustable power of analog power S+ S- Standard RS485 communication terminal Standard isolated485 communication interface. Please use twisted pair or shielded wire 2.7 Wiring of Sensors 2.7.1 Terminal instruction ◆ VO ---5 ~ 24V Power terminal for transmissible pressure gauge/pressure transmitter ◆ AI ---0~10V analog signal input terminal (voltage feedback type) or 4~20mA signal input terminal (current feedback type) ◆ GND --- 5~24V signal common terminal 2.7.2 Sensor configuration instruction A current type pressure sensor will be used by default; output signal is 4~20mA. If use other types of sensors, please refer to the setting parameters P0-03,P0-04, P0-05 in Chapter 4.5. - 16 - PDM30 Series 2.7.3 Wiring diagram The drive can be connected to transmissible pressure gauge and pressure transmitter. Please connect wire according to below diagrams. (1) Transmissible pressure gauge: working voltage 10VDC, output 0~10VDC. Wiring method is shown as below. VO GND AI1 1 2 3 PE Remote pressure gauge 1.0Mpa (2) Pressure transmitter: working voltage range 10 ~ 30V, output 4 ~ 20mA.Wiring method is shown as below. VO GND AI1 Current pressure transmitter Signal line: green Power cord: red Model:PTxxx Power:24VDC Range:0-1Mpa Output:4-20mA Notes: Model for PDM30-2SXXX products will be equipped with dedicated sensors (red line connected to terminal +VO; black line connected to terminal AI). For the wiring method of various sensors and the setting of relevant parameters, please refer to appendix. - 17 - PDM30 Series Chapter 3 Quick Start 3.1 Parameter Settings ★Single machine debugging mode: Under normal circumstances, the machine is equipped with standard input and output lines and sensors. When connecting the pump, the motor connection method needs to be adjusted from the original star (380V) to the delta (220V) working mode; After power on, long press the "+" or "-" key for 3 seconds to enter the pressure setting mode, set the target pressure d, and then press the "start/stop" key to save, and then press the "start/stop" key to start the machine, and the machine will proceed Normal working mode; P0-14 = 1 Power-on self-start function (need to be turned on by the customer) Pump steering confirmation After setting the parameters, you can do a short trial run to observe whether the steering of the water pump is correct. The pump steering can be changed in the following two ways: Stop the inverter and exchange any two phases of the inverter output power lines U, V, W. Stop the inverter and modify parameter P0-02. ★Multi-online mode: Wiring: Connect all the machine terminals S+ that need to be connected in parallel, and all S- in parallel; For parameter setting, refer to the macro parameter table below: - 18 - PDM30 Series Please refer to the table below, to set the system quickly. System Typ Solo Pump setting Two VFDs, as Host drives Three VFDs, as Host drives Four VFDs , as Host drives Five VFDs , as Host drives Six VFDs, as Host drives Emergent Mode Host Driver Auxiailry1 Auxiailry2 Auxiailry3 Auxiailry4 Auxiailry5 P0-47=1 \ \ \ \ \ P0-47=2 P0-47=11 \ \ \ \ P0-47=3 P0-47=11 P0-47=12 \ \ \ P0-47=4 P0-47=11 P0-47=12 P0-47=13 \ \ P0-47=5 P0-47=11 P0-47=12 P0-47=13 P0-47=14 \ P0-47=6 P0-47=11 P0-47=12 P0-47=13 P0-47=14 P0-47=15 P0-47=9 Frequency source changed Terminal wiring diagram (5 auxiliaries at most): - 19 - PDM30 Series Chapter 4 Programming and Parameters Note: “☆”: The parameter can be modified in both standby and operating state. “★”: The parameter can’t be modified in operating state. “ ● ”: The parameter is the actual detected and recorded value which can’t be modified. 4.1Pressure and Protection Function Group Modific Default ationlev el Function code Description Set range Unit P0-00 Pressure setting 1.0~P0-21 0.1bar 3.0 ☆ P0-01 Deviation of pressure 0.0~P0-00 0.1bar 0.3 ☆ Dormancy awakens deviation pressure P0-02 Operation direction selection 0: Same direction 1: Opposite direction 1 0 ☆ Adjustable water pump steering P0-03 Sensor range 1.0~200.0 0.1bar 10.0 ☆ P0-04 Sensor feedback type 0: 4-20mA/24 V 1: 4-20mA/10 V 2:0-10V 3:0.5-4.5V 4:0-5V 1 0 ☆ P0-05 Pressure 0.750 ~ calibration factor 1.250 0.001 1.000 ☆ P0-06 Proportional gain 0.0 ~ P1 100.0 0.1 2.00s ☆ P0-07 Integration time I1 0.01s 0.50s ☆ 0.00s ~ 10.00s - 20 - Notes Different modes can be selected according to the sensor feedback signal used PDM30 Series Function code Description Set range Unit Modific Default ationlev el P0-08 PID function selection 0: off 1: Sleep mode 1 2: Sleep mode 2 P0-09 PID sleep delay 0.0s ~ 100.0s 0.1s 5.0 ☆ P0-10 PID wake-up delay 0.0s ~ 100.0s 0.1s 3.0 ☆ P0-11 PID sleep frequency P1-31 ~ upper limit frequency 0.01Hz 30.00 ☆ P0-12 PID low frequency hold frequency running time 0.0s ~ 120.0s 0.1s 5.0 ☆ P0-13 PID sleep deviation pressure 0.0bar ~ 1.0bar 0.1bar 0.2 ☆ P0-14 Power on automatic start function 0: off 1: open 1 0 ☆ P0-15 Power-on automatic start delay 0.0~100.0 0.1s 5.0 ☆ P0-16 Antifreeze function 0: off 1: open 1 0 ☆ P0-17 Antifreeze operating frequency 0.0~P1-06 0.01Hz 10.00 ☆ P0-18 Antifreeze running time 0~1000 1s 60 ☆ P0-19 Antifreeze operation cycle 0~1000 1s 300 ☆ P0-20 Leakage size factor 0.1~100.0 0.1 5.0 ☆ 1 1 ☆ - 21 - Notes If the frequency is lower than this frequency, the machine will go to sleep After it is turned on, it will start automatically after power-on PDM30 Series Function code Description Modific Default ationlev el Set range Unit P0-00~ P0-08 0.1bar 9.0 ☆ Notes P0-21 High pressure alarm setting value P0-22 High voltage 0.0~120.0 alarm delay time 0.1s 3.0 ☆ P0-23 Low pressure alarm setting value 0.0~P0-00 0.1bar 0.0 ☆ P0-24 Low voltage 0.0~120.0 alarm delay time 0.1s 3.0 ☆ P0-25 Water shortage protection function 0: off 1: Judging water shortage according to frequency and current 2: Judging by frequency and pressure 3: Judging water shortage based on frequency, current and pressure 1 2 ☆ P0-26 Water shortage fault detection threshold 0.0~P0-00 0.1bar 0.5 ☆ Water shortage will be judged below this pressure P0-27 Water shortage 0~Upper protection testing frequency frequency 0.01Hz 48.00 ☆ More than this frequency will judge water shortage P0-28 Water shortage protection 0~100.0 detection current percentage 0.1% 40.0 ☆ When the operating current is less than this current, it is judged as water shortage - 22 - PDM30 Series Function code Description Set range Unit P0-29 Water shortage protection detection time 0.0~200.0 0.1s P0-30 Water shortage protection 0~9999 automatic restart delay P0-31 PID sleep rate P0-32 Modific Default ationlev el 60.0 ☆ After meeting the water shortage condition, alarm after this time After the water shortage fault is reported, after this time delay, the machine resets the fault code 1min 15 ☆ 0 ~ 30 1 9 ☆ Incoming water detection pressure 0.0~P0-00 0.1bar 1.0 ☆ P0-33 Incoming water detection time 0.0~100.0 0.1s 20.0 ☆ P0-34 AI minimum input 0.00V ~ +10.00V 0.01V 2.00V ☆ P0-35 AI maximum input 0.00V ~ +10.00V 0.01V 10.00V ☆ P0-36 Acceleration time 0.0s ~ 1 100.0s 0.1s 2.0s ☆ P0-37 Deceleration time 0.0s ~ 1 100.0s 0.1s 2.0s ☆ 1 0 ★ P0-38 Parameter initialization 0: No operation 1: Restore factory parameters, excluding motor parameters 2: Clear record information - 23 - Notes When the water outlet pressure is greater than this value, the fault will be reset after a delay of P0-30 PDM30 Series Function code Description Modific Default ationlev el Set range Unit 1 0 ☆ 1 0.0 ● P0-39 Parameter function lock 0: The parameter is not locked 1: Parameter lock P0-40 Broken record 0-50 P0-41 Radiator temperature P0-42 Software version . number ● 1.000 - 24 - ● Notes PDM30 Series Function code Description Set range Unit P0-43 Main frequency source X selection 0: Digital setting (no memory after power off) 1: Digital setting (memory after power failure) 2: Keyboard potentiomet er 3: AI1 4: Multi-speed command 5: Simple PLC 6: Digital setting (no memory when power off) 7: Digital setting (no memory after power off) 8: PID 9: Communica tion setting 1 P0-44 System working mode 0: Constant voltage mode 1: Constant speed mode Modific Default ationlev el 8 Notes ★ Adjust this value to change the working mode 1 - 25 - 0 ★ PDM30 Series Function code Modific Default ationlev el Description Set range Unit P0-45 Pressure display mode 0: overall display 1: Independent display 1 0 ☆ P0-47 Application macro selection 0-15 1 0 ★ Notes Refer to the macro parameter setting table for details 4.4 Frequency and Auxiliary Function Group Function Description code Set range Modifi Unit Default cation level P1-00 Multiple online slave backup host action selection 0: stop 1: Constant speed 2: Constant pressure 1 0 ☆ P1-01 Multiple online network mode selection 0: slave 1: Host 1 0 ● P1-02 Number of multi-line auxiliary machines 0~5 1 0 ● Multiple online operating modes 0: Multi-pump main and auxiliary control 1: Multi-pump synchronous control 2: Multiple pumps, one use and one standby control 1 0 ☆ P1-03 - 26 - Notes PDM30 Series Function Description code Set range Modifi Unit Default cation level P1-04 Multi-line rotation interval time 0min~ 2000min 1min 240min ☆ P1-05 Maximum output frequency 50.00Hz ~ 400.00Hz 0.1H z 50.00Hz ★ P1-06 Upper frequency Lower limit frequency P1-07 ~ Maximum frequency P1-05 0.1H z 50.00Hz ☆ P1-07 Lower limit frequency 0.00Hz ~ upper limit frequency P1-06 0.1H z 0.00Hz ☆ P1-08 Frequency is lower than the lower limit frequency action 0: run at lower frequency limit 1: shutdown 2: Zero speed operation 1 0 ☆ P1-09 Carrier frequency 1.0kHz ~ 16.0kHz 0.1k Hz 8.0kHz ★ P1-10 PID feedback loss detection value 0.00 ~ 10.00V 0.01 V 0.20 ☆ P1-11 PID feedback loss detection time 0.0s ~ 100.0s 0.1s 30.0s ☆ P1-12 Motor power selection 0:0.75kW 1:1.5kW 2:2.2kW 1 2 ★ P1-13 Motor rated power 0.1kW ~ 2.2kW 0.1k W 2.2 ★ P1-14 Motor rated frequency 0-Maximum frequency P1-05 0.1H z 50.00 ★ P1-15 Motor rated voltage 0-380V 1 220 ★ - 27 - Notes Maximum adjustable frequency range of the machine The factory is 2.2kW, the customer needs to adjust the settings according to the actual pump PDM30 Series Function Description code Set range Modifi Unit Default cation level P1-16 Motor rated current 1.00-10.00 0.01 A 9.60 ★ P1-17 User password 0 ~ 65000 1 0 ☆ P1-18 DI1 terminal function selection 1 1 ★ P1-19 DI2 terminal function selection 1 10 ★ P1-20 DI filter time 0.000s ~ 1.000s 0.001 s 0.010s ☆ P1-21 DI1 enable delay time 0.0s ~ 100.0s 0.1s 1.0s ☆ P1-22 DI2 enable delay time 0.0s ~ 100.0s 0.1s 1.0s ☆ P1-23 DI1 disable delay time 0.0s ~ 100.0s 0.1s 0.0s ☆ P1-24 DI2 disable delay time 0.0s ~ 100.0s 0.1s 0.0s ☆ P1-25 Automatic fault reset times 0 ~ 10 1 5 ☆ P1-26 Automatic fault reset time 0.0 ~100.0s 0.1s 30.0s ☆ Cooling fan control 0: The cooling fan runs when the motor is running 1: Automaticall y operate according to the radiator temperature 1 1 ☆ P1-27 0: No function 1: Forward running FWD -10: External fault input (normally open) - 28 - Notes PDM30 Series Function Description code Set range Modifi Unit Default cation level P1-28 Stop mode 0: Decelerate to stop 1: Free parking 1 0 ☆ P1-29 Keyboard setting frequency 0.00Hz ~ maximum frequency P1-05 0.01 Hz 50.00Hz ☆ P1-30 PID action direction 0: positive effect 1: Counteractio n 1 0 ☆ P1-31 PID low frequency hold frequency 0.00Hz ~ 50Hz 0.01 Hz 20.00 ☆ P1-32 Sleep detection cycle 0.0 ~ 1000.0 0.1s 30.0 ☆ PWM mode 0: CPWM 1: CPWM and DPWM switching 1 1 ★ P1-34 Command source selection 0: Operation panel command channel (LED off) 1: Terminal command channel (LED on) 2: Serial port communicati on command channel (LED flashes) 1 0 ☆ P1-35 Local address 1~6, 0 is the broadcast address 1 1 ☆ P1-33 - 29 - Notes The machine detects sleep at this time Choose different start and stop methods PDM30 Series Function Description code Set range Modifi Unit Default cation level Baud rate 0:4800 bPS 1:9600 bPS 2:19200 bPS 3:38400 bPS 1 1 ☆ P1-37 Data Format 0: No parity (8.N.1) 1: Odd parity (8.O.1) 2: Even parity (8.E.1) 1 0 ☆ P1-38 Response delay 0ms ~ 20ms (0~200ms) 1ms 2 ☆ P1-42 Motor type selection 0: Three-phase motor 1: Single-phase motor 1 0 ★ P1-43 Single-phase motor main and auxiliary winding turns ratio 10 ~ 200 1 100 ☆ P1-44 Single-phase motor current correction factor 50 ~ 200 1 150 ☆ P1-45 Water shortage protection reset times 0~9999 1 10 ☆ P1-47 Parameter hidden selection 0: not hidden 1: hidden 1 1 ☆ P1-36 - 30 - Notes PDM30 Series 4.5 Parameter Setting Procedure Taking the commonly used parameters of P0-00 - P0-05 as an example, the parameters setting steps are as follows. Set P0.00 (Pressure setting) Notes: Pressing “ + ” or “ - ” to modify the setting pressure as 4.0 in the stop displayed status Set P0.01 (Startup pressure derivation) Set P0.02 (Running direction) - 31 - PDM30 Series Set P0.03 (Sensor range) Set P0.04 (Sensor feedback type) Set P0.05 (Power setting of sensor) - 32 - PDM30 Series 4.6 Programming Description of Parameters P0-00 Pressure setting 0.0~P0-03 bar 3.0 P0-03 Sensor range 0.0~200.0 bar 10.0 P0-04 Sensor feedback type 0:Voltage feedback 1:Current feedback The maximum range of sensor 1 P0-03 is the range of the sensor. Common range is 1MPa, namely 10.0bar. P0-00 is the pressure value of the pipe network. If P0-00=3.0bar, after the smart pump drive is started, the pressure of the pipe network keeps constant at 3.0 bar. General sensor is in current type. The wiring method of SPD is similar to pressure transmitter, connected to AI terminal as pressure feedback: if voltage sensor is use, please modify P0-04 to 0. The wiring method of SPD is similar to transmissible pressure gauge, connected to AI terminal as pressure feedback. When feedback value is smaller than or equal to set pressure minus PID start pressure(P0-00~P0-01), and it holds the state in P0-10 set time, PID adjustment will be restarted. For example, when P0-00=3,P0-01=0.3,P0-10=5.0, if feedback value is smaller than or equal to 2.7, and the time is longer than 5s, PID adjustment will be restarted. Once it is larger than 2.7, the time will recount. P0-01 Start pressure deviation 0.0~P0-00 bar 0.3 The value that is lower than PID set pressure P0-10 PID wakeup detection delay 0.0~100.0 s 3.0 PID wakeup detection delay - 33 - PDM30 Series P0-02 Running direction of motor 0:Forward 1:Reverse 0 Modify this parameter to change running direction In initial use, confirm the rotation direction of motor. Exchange arbitrary two lines of output power line U, V, W of the SPD or modify parameter P0-02 to change the rotation direction of the motor. P0-06 Proportional 0.0~100.0 % gain The larger the parameter, the faster the response speed of the pressure system. However, when it 2 is set too big, the system will oscillate. Adjust it according to different water supply system. Adjustment method: If factory parameters can’t meet demands, adjust parameters finely. First increase proportional gain to make sure that the system will not oscillate. Note: improper parameter setting of P0-06 will cause huge speed overshoot, and even over voltage fault in overshoot back. - 34 - PDM30 Series P0-08 PID sleep choices 0~2 PID sleep detection P0-09 delay 0.0~ 120.0 2 0:Sleep invalid 1:Sleep mode 1 2:Sleep mode 2 s 1.0 In small water consumption, if sleeping is slow or it can’t sleep, make the value smaller; if it sleeps in advance or it starts and stops frequently, make the value bigger. P0-10 PID wakeup detection delay 0.0~ 120.0 s 1.0 PID wakeup detection delay P0-11 PID sleep low level hold frequency 0.00~ 60.00 Hz 35.00 PID runs at sleep low level hold frequency. After the time of P0-12, PID sleeps. Running time at PID P0-12 low level hold frequency 0.00~ 3600 s 3.0 PID sleep deviation pressure 0.0~ P0-01 bar 0.1 P0-13 - 35 - If feedback pressure is in sleep deviation range, start sleeping treatment. PDM30 Series After selecting sleep mode 1 by parameter P0-08, the SPD will detect whether feedback pressure is higher than set pressure. If yes, the SPD will start sleep detection. After PID sleep detection delay set by P0-09, if feedback pressure is still higher than set pressure, SPD will decrease output frequency gradually to sleep detection low level hold frequency set by P0-11. After sleep detection low level hold frequency waiting time, if feedback pressure is still higher than set pressure, the SPD decreases output frequency to 0Hz and enter standby. If in above process, feedback pressure is lower than set pressure, the SPD will judge as invalid sleep detection and come back to PID adjustment status. After the SPD enters standby, if feedback pressure is lower than PID sleep threshold, SPD will start wakeup detection. After PID wakeup detection delay set by P0-10, if feedback pressure is still lower than wakeup pressure threshold, wakeup is successful and SPD comes back to PID adjustment status; else, wakeup fails. Too high PID sleep threshold may cause frequent start and stop of the SPD. Too low PID sleep threshold may cause deficient pressure. Notes: sleep holding frequency of different water supply system is different. When there is no water outside and the water tap is turned off, but the pump is still running, increase P0-11 to sleep holding frequency. Ones:Auto-start choices 0:OFF Automatically 1:ON P0-14 start self-reset Tens:Fault self-reset choices at power on 0:OFF 10 By default, self-reset is ON and auto-start is OFF. 5.0 Delay time before auto-start at power on 1:ON P0-15 Auto-start delay at power on 0.0~100.0 s If you hope that the SPD can start automatically after time delay set by P0-15 at power on, after setting all parameters, make P0-14 = 1 to enable auto-start function of the SPD. Every time at power on or fault reset, it will start automatically. - 36 - PDM30 Series 0:OFF P0-16 Antifreeze 0 P0-17 Anti-freezing running frequency 0.0~60.00 Hz 8.00 P0-18 Anti-freezing running time 0~9999 s 60 P0-19 Anti-freezing running interval 0~9999 s 300 1:ON Self anti-freezing function of pump When it is set as 0, it keeps running at anti-freezing running frequency Set P0-16=1 to enable anti-freezing function. The SPD will adjust the running frequency of pump according to current status after it is started. Note: Pump auto-adjusting given frequency is prior to anti-freezing frequency. Anti-freezing frequency can’t be set to high. It should be set as the frequency that can just drive the pump but can’t supply pressure. Water P0-20 leakage coefficient 0.0~100.0 1.0 The bigger the water leakage, the bigger the coefficient. In no water consumption, because of water leakage of pipe network, the SPD can’t sleep and stop. It starts and stops frequently. To solve the water leakage problem of pipe network, modify the value of P0-20 according to water leakage. The bigger the water leakage, the bigger the coefficient. - 37 - PDM30 Series P0-21 Set value of high pressure alarm 0.0~P0-03 bar 8.0 P0-22 Detection time of high pressure alarm 0.0~200.0 s 3.0 P0-23 Set value of low pressure alarm 0.0~P0-21 bar 0.0 P0-24 Detection time of low pressure alarm 0.0~200.0 s 3.0 When feedback pressure is bigger than or equal to the set value, after the delay of P0-22, it alarms and stops. When feedback pressure is smaller than the set value, after the delay of P0-24, it alarms and stops. This function is invalid when it is set to 0. The SPD will compare P0-21 and P0-23 according pipe network pressure fed back by sensor. If pressure is abnormal, it will stop and alarm automatically to protect pipe network system. 2 0: off 1: Judging water shortage according to frequency and current 2: Judging by frequency and pressure 3: Judging water shortage based on frequency, current and pressure bar 0.5 It judges water shortage only when feedback pressure is smaller than the set value. 0~ 60.00 Hz 48.00 It is valid when P0-25 = 01. Comparison frequency of water shortage judgment. Current percentage of water shortage protection detection 0-100 % 40.0 It is valid only whenP0-25=01. Percentage of motor rated current. Water shortage protection detection time 0~ 900.0 s 60.0 P0-25 Water shortage protection 0-3 P0-26 Water shortage fault detection threshold 0.0~ P0-00 P0-27 Water shortage protection detection frequency P0-28 P0-29 - 38 - PDM30 Series P0-30 Self-restarting delay of water shortage protection 0~ 9999 min If it is set to be 0, use pressure to self-reset water shortage. 15 Following methods can realize water shortage protection by default: (1)The switch of water shortage protection is turned on(P0-25=X); (2)The feedback pressure is less than allowed threshold value of water shortage detection(feedback pressure<P0-26); ( 3 ) The current running frequency is no less than water shortage protection detection frequency(running frequency>=P0-27); (4)When (1)-(3) are satisfied, timing starts. When the time meeting the condition exceeds abnormal pressure alarm delay time (delay time>P0-29), water shortage fault will be reported. When either condition is not satisfied during timing, timing recounts. When water shortage fault is reported, after the time set by P0-30, the drive will reset. By setting the next following parameters: P0-32 Inflow detection pressure 0.0~P0-00 bar 1.0 P0-33 Inflow detection time 0.0~100.0 s 20.0 - 39 - PDM30 Series Use inflow detection pressure to reset water shortage faults directly. Note:When judge water shortage according to pressure, because the working condition of each drive is different such as range of load size, only setting the value of P0-28 reasonably according to site conditions can it make correct judgment to water shortage. Setting method: Run the drive. When running frequency reaches maximum frequency, turn off inlet and record the output current displayed on the drive. Divide this current by P1-16 (the rated current of the motor) to get a percentage. Make the value of P0-28 a little higher than 5-10 percentage points of the percentage. Too high value of P0-28 will lead to false water shortage report in normal operation. Water shortage protection will not work effectively with too low value of P0-28. P0-34 Lower limit of AI input signal 0.0~ P0-35 V/mA 2.00 Used to correct lower limit of AI signal P0-35 Upper limit of AI input signal P0-34~ 20 V/mA 10.00 Used to correct upper limit of AI signal If you find there is some deviation between sensor feedback pressure and feedback pressure displayed on SPD, adjust above parameter to correct the sensor. Note: the unit of current sensor is 4~20mA; that of voltage sensor is 0~10V. P0-36 P0-37 Acceleration time 0.1~3600 s 2.0 Deceleration time 0.1~3600 s 2.0 Acceleration/deceleration time setting of the pump’s motor. P0-38 Parameter initialization 0~2 When P0-38 is set as 1, restore factory defaults. - 40 - 0 PDM30 Series P0-39 0~1 Parameter lock function 0 After setting parameters, if you don’t want them to be modified by misoperation, make P0-39= 1. At this time, parameters can only be monitored, but not be modified. Only when P0-39 is modified to 0, can parameters be modified. P0-40 Current fault type 0~29 Record fault type of the SPD. 0 means no fault. 1~29 refers to E001~E029. For more details, please refer to fault inspection and troubleshooting chapter. P1-34 Start/stop signal choices 0~1 0 P0-43 Frequency source choices 0~8 8 0:Start/stop by keyboard 1:Start/stop by terminals 0:Digital setting 1~7:Reserved 8:Water supply PID Each SPD can choose different start/stop modes and frequency sources. P1 group parameters have the same meaning as P0 group. Please refer to P0 group for more details. P1-06 Upper limit frequency P1-07~60.0 Hz 50.00 P1-07 Lower limit frequency 0.00~P1-06 Hz 0.00 0:Run at lower limit frequency Action choices when P1-08 running frequency is lower 1:Stop than lower limit frequency 2:Standby - 41 - 2 PDM30 Series P1-06 limits the maximum working frequency of SPD. Use P1-08 to choose running status of SPD when running frequency is lower than lower limit frequency. To prevent motor from being in low speed operation for a long time, you can use this parameter to stop it. If use a 60Hz pump, please set parameters according to the following steps. Step 1: Set the parameter P1.06 (Upper limit frequency) to 60 Step 2: Set the parameter P1.13 (Motor rated frequency) to 60 P1-09 Carrier frequency setting 1.0~15.0 kHz Set according to models Use this parameter to adjust carrier frequency of SPD. You can decrease motor noise by adjusting carrier frequency, avoid point of resonance, decrease leakage current of wires to ground and decrease interference of SPD. When carrier frequency is high, motor loss decreases, temperature rising of motor is small, but SPD loss increases, temperature rising of SPD increases and interference increases. - 42 - PDM30 Series P1-10 Feedback broken line detection value 0.0~1.00 V 0.20 P1-11 Feedback broken line detection time 0.0~3600 s 30.0 Feedback broken line detection value: the detection value is relative to input signal voltage. System keeps detecting PID feedback value. When feedback value is smaller than or equal to feedback broken line detection, system starts detection timing. When detection timing exceeds feedback broken line detection time, system will report PID feedback broken line fault. Please set according to parameters of the motor nameplate. To guarantee control performance, please configure motor according to standard adaptive motor of drives. If there is big difference between motor power and standard adaptive motor, control performance of drives will decrease obviously. - 43 - PDM30 Series Chapter 5 Fault Information and Troubleshooting 5.1 Fault Codes Description Fault code E001 Fault type Possible reasons 1.Too fast acceleration 1.Increase acceleration time 2.IGBT inside broken 2.Seek for support Invert cells fault 3.Malfunction caused by interference 4..Sound grounding or not E002 1.Too fast acceleration Over current in 2.Too low grid voltage accelerated running 3.The power of the SPD is too low 1.Too fast deceleration E003 E004 Over 2.The inertia torque of load is current in decelerated too big. running 3.The power of the SPD is too low Over current in constant speed running Solution 3.Check whether peripheral equipments have strong interference source 4.Check grounding line 1.Increase acceleration time 2.Check input power 3.Use bigger power SPD 1.Increase deceleration time 2.Add proper dynamic braking modules 3.Increase power of the SPD 1.Saltation or abnormality happens to load 1.Check the load or decrease the saltation of the load 2.The grid voltage is too low 2.Check input power supply - 44 - PDM30 Series Fault code Fault type Possible reasons 3.The power of the SPD is too low E005 Solution 3.Use bigger power SPD 1.The input voltage is abnormal 1.Check input power supply Over voltage in accelerated 2.Restart rotating motor after 2.Avoid restarting after it is stopped running momentary outages 1.Too fast deceleration 1.Increase acceleration time Over voltage in E006 decelerated 2.The inertia of load is too big 2.Increase dynamic braking modules running 3.The input voltage is abnormal. 3.Check input power E007 E008 E009 Over voltage in constant speed running Hardware over voltage 1.Abnormal changes happen to 1.Install input reactor input voltage 2.The inertia of load is too big 1.The input voltage is abnormal 1.Check input power supply 2.Too fast deceleration 2.Increase deceleration time 3.The inertia of load is too big 3.Increase dynamic braking modules Bus under 1.The grid voltage is too low voltage 1.Too fast acceleration E010 2.Add proper dynamic braking modules Controller 2.Restart rotating motor overload 3.The grid voltage is too low - 45 - 1.Check grid input power supply 1.Increase acceleration time 2.Avoid restarting after it is stopped 3.Check grid voltage PDM30 Series Fault code E011 E013 E014 Fault type Motor overload Possible reasons Solution 4.Overload 4.Use bigger power SPD 1.The grid voltage is too low 1.Check grid voltage 2.Wrong setting to motor rated current 2.Reset motor rated current 3.Motor stall or big changes to load 3.Check the load and adjust torque lifting capacity 4.Motor is too small 4.Use proper motor U,V,W phase loss output(or the Output three phases of load is not phase loss symmetrical) 1.Check output wiring 2.Check motor and cable 1.Instant over current of SPD 1.Refer to over current solutions 2.Output three phases have interphase or ground is short circuit 2.Re-wiring 3.Air passage block or fan Module broken overheatin g 4.The environmental temperature is too high 3.Dredge air passage or change fan 4.Decrease environmental temperature 5.SPD wire or plugins loose 5.Check and re-connect 6.Power circuit irregularity 6.Seek for service - 46 - PDM30 Series Fault code Fault type Possible reasons Solution 8.Control board exception E015 External water shortage Water shortage is detected Check whether water is deficient. 1.Poor contact of control board 1.Check connector and re-plug connector E018 Fault of current detection circuits 2.Power circuit irregularity 3.Damage to hall devices 2.Seek for service 4.Exception of amplifying circuit E022 E023 E024 1.Read write of control EEPROM parameter goes wrong read write faults 2.EEPROM broken Torque rich 1.Press RUN/STOP key to reset 2.Seek for service 1.Too fast acceleration 1.Increase acceleration time 2.Restart rotating motor 2. Avoid restart rotation motor 3.Grid voltage is too low 3.Check grid voltage 4.Load is too heavy 4.Use big power SPD 1.Sensor broken line or poor contact 1.Check the installation and wiring of sensor PID feedback 2.Broken line detection time is broken line too short fault 3.The sensor is broken or the system has no feedback signal - 47 - 2..Increase broken line detection time 3.Change sensor PDM30 Series Fault code Fault type E025 Running time 1.Running time reaches set time 1.Seek for service reaches set time E026 Reserved E027 Water shortage alarm Possible reasons Solution Reserved Reserved 1.Water pressure/level exception 1.Check whether the pressure of inlet is abnormal or not 2.Sensor broken line or poor contact. System has no feedback signal 2.Check the installation and wiring of sensor 3.Water shortage alarm detection time is too short(P0-29) 4.Water shortage protection frequency is too low(P0-27) 3.C heck relevant parameter settings 5.Water shortage protection detection current is too low(P0-28) 1.Feedback signal of senor exception E028 High pressure alarm 2.High pressure alarm value adjustment is too low(P0-21) 3.Alarm detection time adjustment is too short(P0-22) E029 Low pressure alarm 1.Check the wiring of sensor 2.Check relative parameter settings 1.Low pressure alarm value is set too high(P0-23) 1.Modify parameters 2.Sensor broken line or poor contact. System has no feedback signal 2.Check the sensor - 48 - PDM30 Series Fault code Fault type Possible reasons 3.Sensor type is inconsistent with actual situation - 49 - Solution PDM30 Series 5.2 Common Faults and Actions The following faults may happen in use. For brief fault analysis, please refer to the following methods. 5.2.1 No display at power on (1) Check whether the input power is consistent with the nominal voltage of the drive with multimeter. (2) Check whether the three-phase rectifier bridge is intact. If the rectifier bridge is broken down, please request service. 5.2.2 The power air switch trips off at power on. (1) Check whether there is short circuit or ground connection between input power. If yes, please eliminate it. (2) Check whether the rectifier bridge has been broken down. If yes, please request service. 5.2.3 The motor doesn’t rotate after the SPD runs. (1) Check whether there is balanced three-phase output among U, V,W. If yes, check whether the motor is broken or blocked. If no, please confirm whether the motor parameters are set correctly. (2) If there is output but the three-phase power is not balanced, please request service. (3) If there is no output voltage, please request service. 5.2.4 SPD shows normally at power on but the power air switch trips off after running. (1) Check whether short circuit occurs between output modules interval. If yes, please request service. - 50 - PDM30 Series (2) Check if there is short circuit or ground connection between motor leads. If yes, please eliminate it. (3) If switch stripping off occurs occasionally and the distance between motor and inverter is far, consider to add output AC reactor. 5.2.5 It doesn’t stop in no water use. (1) Check whether the feedback pressure displayed on the SPD board is no less than set pressure. If the feedback pressure is less than set pressure, please check whether the range of the pressure sensor is set correctly, whether the pump rotates reversely, whether there is air and whether the inlet is blocked by sundries. (2) If the feedback pressure is no less than set pressure, please decrease the set value of P0-09 and increase P0-11. (3) If feedback pressure changes nearby set value, stop the SPD manually and see whether the pressure decreases. If yes, check valve needs to be changed. 5.2.6 It can’t sleep in small amount of water use or leakage (1) If it can’t sleep or the sleep time is too long, decrease P0-09 and increase P0-11, If it is still not effective, increase P0-31. (2) If it sleeps in advance, first increase P0-09. If it is still not effective, decrease P0-20. (3) If it starts and stops frequently, first increase P0-09. If it is not effective, increase P0-20. If it is still not effective, increase P0-01. 5.2.7 It can’t stop to make protection in water shortage. (1) Water shortage protection switch P0-25 is not enabled. (2) The threshold value of water shortage detection P0-26 is set too low. (3) The current percentage of water shortage detection P0-28 is set too low. - 51 - PDM30 Series Chapter 6 Warranty Policy Standard Warranty Period: The pump controller manufacturer grants a standard warranty period of 18 months (1.5 years) for the pump controllers, starting from the date of shipment from manufacturer factory or 12 months (1 year) starting from the date of purchased invoice marked (whichever is longer). Warranty Conditions: If your pump controller gets fault and requires troubleshooting, please contact your distributor or dealer directly. Alternatively, feedback briefly to manufacture service hotline for logging and send your warranty card to our service department by fax/email to process the warranty claim. During the warranty period, the pump controller manufacturer covers all costs for replacing any product or parts of the product proved to be defective in design or manufacture. To claim the warranty under the warranty policy of pump controller manufacturer, you need to supply us with the following information and documentation regarding the faulty pump controller: 1. Product model No.(e.g. PDM30-2S2R2) and serial No. (e.g.C121661B280H000292YA). 2. Copy of the invoice and warranty certificate of the controller. 3. Copy of the installation report and installation date. 4. Error message on LED screen ( if available ) or any information which would be helpful to determine the defect 5. Detailed information about the entire system (modules, circuits, etc.). 6. Documentation of previous claims/exchanges (if applicable). After receiving above information, The pump controller manufacturer will decide how to proceed the service: Repaired by manufacture factory, or Repaired on-site by manufacture service center, or Offer a replacement device of equivalent value according to model and age. In the case of an exchange, the remaining portion of the original warranty period will be - 52 - PDM30 Series transferred to the replacement device. You will not receive a new certificate, as your entitlement is documented at pump controller manufacturer. If the pump controller needs to be replaced following assessment, manufacture will send a replacement unit immediately. The defective pump controller should be sent back to the closest manufacture service center by packing in its original package if possible. - 53 - PDM30 Series Product warranty Card Company name: Custome Company address: r info. Contact: Tel.: Fax: Zip code: Product model: SN code: Buying date: Fault date: Motor power: Application situation: Product info. Fault description: Fault info. Signature: Date: - 54 - PDM30 Series - 55 - ">
/
ડાઉનલોડ કરો
માત્ર એક મૈત્રીપૂર્ણ રીમાઇન્ડર. તમે અહીં જ દસ્તાવેજ જોઈ શકો છો. પરંતુ સૌથી મહત્વપૂર્ણ બાબત એ છે કે, અમારા AI એ તેને પહેલેથી જ વાંચી લીધો છે. તે જટિલ બાબતોને સરળ શબ્દોમાં સમજાવી શકે છે, કોઈપણ ભાષામાં તમારા પ્રશ્નોના જવાબ આપી શકે છે અને તમને સૌથી લાંબા અથવા સૌથી જટિલ દસ્તાવેજોને પણ ઝડપથી નેવિગેટ કરવામાં મદદ કરી શકે છે.
જાહેરાત