GWP Recommendation
Specimen for IND
With GWP ® Recommendation:
– You purchase only equipment with the right accuracy to meet your process and quality requirements
– You take into account environmental and regulatory factors before the selection
GWP ® Recommendation is globally available for free and can be issued for any
METTLER TOLEDO balance or scale.
You have downloaded a specimen highlighting the scientific selection of a balance or scale based on your process requirements.
GWP ® Recommendation provides documented evidence that the instrument selected meets metrological, environmental and regulatory requirements.
GWP
®
Recommendation
Customer No.
Company
Contact
Department / Position
Building
Street
Zip Code / City
State / Country
Phone
12-34543
BabyFood & Co
Mr. John E. Sample
Production / Manager
PROD-2
Sample Street 11
112233 / Sampleville
NY / USA
+1 123 456 789
Recommended Instrument
Scale
Manufacturer
Maximum capacity
Readability (d)
Built-in adjustment mechanism
Hazardous zone
Wet application (> IP 65)
KCC 150/s (HR)
METTLER TOLEDO
150
0.001
kg kg no no yes
Date: Monday, 10. December 2012
Requirements/Typical Value
Weighing Accuracy
Maximum Weighing Load Required
Minimum Weight Required
Minimum Weight Typical
Safety Factor Required
Safety Factor according to Typical
Minimum Weight
Standards and Regulations
Expansion Factor k
Value Unit
1
140
200
0.1
1)
% kg g kg
2
2
GFSI (IFS, BRC, SQF),
ISO (9001, 22000,
…)
2
METTLER TOLEDO recommends GWP® Verification to determine the actual minimum weight of this instrument on site.
Furthermore, GWP® Verification provides all necessary information on testing procedures, frequencies and weights to maintain reliable weighing accuracy throughout the lifecycle of the instrument.
The GWP® Verification document can be issued for all models and suppliers of scales and scales. Through its risk-based approach it provides optimal performance verification activities at lowest costs.
Ask METTLER TOLEDO for an assessment of your installed base of weighing equipment to reduce costs and risks. Plus, receive complete audit-compliant documentation at one glance. www.mt.com/GWP.
MTLABTEC-213-20121210-2-1 1 / 2
Readability (display resolution) of a balance or scale often is mistaken for accuracy. As a matter of fact, readability is just one contributor to the measurement uncertainty, which is the scientific expression of an instrument's accuracy. To ensure accurate measuring, you must consider at least the following factors prior to the selection of a new balance or scale:
GWP ® Recommendation
Customer No.
Company
Contact
Department / Position
Building
Street
Zip Code / City
State / Country
Phone
12-34543
BabyFood & Co
Mr. John E. Sample
Production / Manager
PROD-2
Sample Street 11
112233 / Sampleville
NY / USA
+1 123 456 789
Recommended Instrument
Scale
Manufacturer
Maximum capacity
Readability (d)
Built-in adjustment mechanism
Hazardous zone
Wet application (> IP 65)
KCC 150/s (HR)
METTLER TOLEDO
150
0.001
no kg kg no yes
1
Date: Monday, 10. December 2012
2
Requirements/Typical Value
Weighing Accuracy
Maximum Weighing Load Required
Minimum Weight Required
Minimum Weight Typical
Safety Factor Required
Safety Factor according to Typical
Minimum Weight
Standards and Regulations
Expansion Factor k
Value Unit
1
140
200
0.1
1)
2
% kg g kg
2
GFSI (IFS, BRC, SQF),
ISO (9001, 22000,
…)
2
3
METTLER TOLEDO recommends GWP® Verification to determine the actual minimum weight of this instrument on site.
Furthermore, GWP® Verification provides all necessary information on testing procedures, frequencies and weights to maintain reliable weighing accuracy throughout the lifecycle of the instrument.
The GWP® Verification document can be issued for all models and suppliers of scales and scales. Through its risk-based approach it provides optimal performance verification activities at lowest costs.
Ask METTLER TOLEDO for an assessment of your installed base of weighing equipment to reduce costs and risks. Plus, receive complete audit-compliant documentation at one glance. www.mt.com/GWP.
1 Customer information
2 Instrument information
3 Weighing requirements and achievements: Color codes pinpoint accuracy and safety factor
MTLABTEC-213-20121210-2-1 1 / 2
4
5
4 Appropriate test weights and weight classes
5 Detailed explanations and remarks
Mettler-Toledo AG
CH-8606 Greifensee, Switzerland
Phone +41 44 944 22 11
Fax +41 44 944 30 60
Subject to technical changes
© 01/2013 Mettler-Toledo AG
Printed in Switzerland xxxxxxxx
MCG MarCom Greifensee www.mt.com
For more information
GWP
®
Good Weighing Practice™
GWP ® is the only science-based global standard for efficient lifecycle management of weighing systems, applicable to all kinds of weighing systems of any manufacturer. It helps you to
• choose the right balance or scale
• calibrate and operate your weighing equipment with security
• comply with current quality, compliance, laboratory and
manufacturing standards www.mt.com/GWP