Black Box NetRack RM506-R2 Manual
PDF
Documento
Pubblicità
Pubblicità
© Copyright 2000. Black Box Corporation. All rights reserved. 1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 RM500A-R2 RM501-R2 RM502 RM503-R2 JUNE 2000 RM505A-R2 RM506-R2 RM507 RM508-R2 NetRack What You Should Have Received Please take a moment to make sure that you received everything that’s included with your order. Each product is described below. RM500A-R2: (1) NetRack, black. The Rack is 85"H x 26"W x 32"D (215.9 x 66 x 81.3 cm). It consists of a welded frame with 2 sets of adjustable rails, a full-length steel rear door with a lock, and 2 perforated shelves. It also has vented, lift-off side panels, a removable top panel, an open bottom for wire/cable access, and a locking plexidoor. RM501-R2: (1) Top fan panel, black. RM502: (2) Bottom-mount tower shelves, black. (For a complete list of the included hardware, see page 2.) RM503-R2: (1) 12-gauge-steel caster base with four 3-inch non-locking casters, black. RM505A-R2: (1) NetRack, beige. The Rack is 85"H x 26"W x 32"D (215.9 x 66 x 81.3 cm). It consists of a welded frame with 2 sets of adjustable rails, a full-length steel rear door with a lock, and 2 perforated shelves. It also has vented, lift-off side panels, a removable top panel, an open bottom for wire/cable access, and a locking plexidoor. RM506-R2: (1) Top fan panel, beige. RM507: (2) Bottom-mount tower shelves, beige. (For a complete list of the included hardware, see page 2.) RM508-R2: (1) 12-gauge-steel caster base with four 3-inch non-locking casters, beige. CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: [email protected] NETRACK The NetRack These fully welded and assembled racks are constructed of heavy 12-gauge steel. The mounting angles, also made of 12-gauge steel, are tapped with #10-32 thread in the E.I.A. RS 310-D universal pattern. There’s ample space inside the frame sides for cabling, so large bundles of wire and cable fit without a problem. Plus, there’s a locking door with a “slam latch” that provides quick access and security. And the doors can easily be changed from left- to right-opening with a quick-release pin. Removable top panel for cable entry and exit Standard knockouts for cables or conduit Vented side panels “snap” into place Mounting angles adjust to any depth within the frame Easy-lift handles on the side panels with locking feature Open bottom panel ⁄2-13 weldnut for levelers or 3⁄8" diameter anchor bolts (4 places) 1 Vents Frames may be bolted to the floor Frames may be joined together for modular use 1 NETRACK Bottom-Mount Tower Shelves (RM502, RM507) The following items are included with the RM502 or RM507. Table 1. Items included with the RM502 or RM507 Key Description Quantity 1 Support plate 4 2 1 ⁄4-20 x 1⁄2" hexbolt 8 2A 1 ⁄4-20 x 1⁄2" carriage bolt 8 3 1 ⁄4-20 hexnut 8 4 Slide bracket 4 5 Slide assembly 4 6 10-32 x 3⁄8" panhead screw (included with slide) 8 7 10-32 hexnut (included with slide) 8 8 10-32 x 5⁄8" cuphead screw 16 9 Shelf assembly 2 You must supply the following tools: • 3⁄8" nutdriver or socket • 7⁄16" socket and ratchet • 7⁄16" end wrench NOTE Shelves may be installed to slide out toward the front or the rear of the cabinet, whichever you prefer. 1. Attach support plates (item 1) to the cabinet base. Make sure that the flange is oriented as shown in Figure 1, and attach it using 1⁄4-20 x 1⁄2" hexbolts (item 2) or 1⁄4-20 x 1⁄2" carriage bolts (item 2A) and 1 ⁄4-20 hexnuts (item 3). If the unit has round holes, use item 2. If the unit has square holes, use item 2A. Tighten the hardware securely. Repeat for remaining plates. 2 NETRACK 1 3 2 Figure 1. Attaching support plates to the cabinet base. 2a. Loosely attach the slide bracket (item 4) to the rear of the slide (item 5) as shown below, using two 10-32 x 3 ⁄8" panhead screws (item 6) and two 10-32 hexnuts (item 7). Do not tighten at this time. 4 7 8 6 5 Figure 2. Attaching the slide bracket to the rear of the slide. 2b. Extend the slide/bracket assembly so that it will extend around the outside of the support plates installed in step 1. Attach the slide/bracket assembly to support plates with four 10-32 x 5⁄8" cuphead screws (item 8) and tighten securely. (Keep the slide/bracket assembly tight against the side of the support plate when tightening.) 2c. Tighten the screws and hexnuts installed in step 2a. 2d. Repeat 2a, 2b, and 2c for the remaining slides. 3 NETRACK 3a. Extend the inner slide members of slides to the front of the unit until they lock in place. Take the shelf assembly (item 9) and carefully insert slide members attached to the inside of the shelf into extended slide members. Slide the drawer all the way to the rear of the cabinet to engage. 9 Extend inner slide members until they lock in position Engage slide members attached inside shell at factory to slide members on frame Figure 3. Sliding the drawer into the cabinet. 3b. Test the shelf by extending and retracting to assure proper engagement. TRADEMARKS Any trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. 4 ">
/
Scarica
Solo un promemoria. Puoi visualizzare il documento qui. Ma soprattutto, la nostra IA l''ha già letto. Può spiegare cose complesse in termini semplici, rispondere alle tue domande in qualsiasi lingua e aiutarti a navigare rapidamente anche nei documenti più lunghi o complicati.
Pubblicità