Lippert EBL 216 Separate Display Board User Manual
PDF
Dokument
Annons
Annons
Instruction Manual R Electrobloc EBL 216 Table of contents 1 1.1 1.2 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meaning of safety symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 2 2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 3.1 3.2 3.3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switching system on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Closing down the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 4 5 4 4.1 4.2 Application and Functions in Detail . . . . . . . . . . . . . . . . . . . . . . . . Battery functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Additional functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 8 9 5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt--gmbh.de 811.575 BA / EN Date: 26.09.2014 Instruction Manual Electrobloc EBL 216 1 1.1 Safety Information Meaning of safety symbols DANGER! Failure to heed this warning may result in death or serious injury. Y WARNING! Failure to heed this warning may result in personal injuries. Y ATTENTION! Failure to heed this warning may result in damage to the device or connected consumers. Y 1.2 General safety information The device is state-of-the-art and complies with approved safety regulations. Nonetheless, personal injuries or damage to the device may occur if the safety instructions contained herein are not followed. Ensure that the device is in perfect working order before use. Any technical faults which may have an adverse effect on personal safety or device safety must be rectified immediately by qualified personnel. DANGER! 230 V mains voltage carrying parts. Danger of death due to electric shock or fire: Y F F F Do not carry out maintenance or repair work on the device. If cables or the device housing are damaged, no longer use the device and isolate from the power supply. Ensure that no liquids enter the device. WARNING! Hot components! Burns: Y F F Only replace blown fuses once the cause of the fault has been identified and rectified. F Never bypass or repair fuses. F Only use original fuses rated as specified on the device. F Device parts can become hot during operation. Do not touch. F 2 Only replace blown fuses when the device is completely de-energised. Never store heat sensitive objects close to the device (e.g. temperature sensitive clothes if the device has been installed in a wardrobe). Date: 26.09.2014 811.575 BA / EN Instruction Manual Electrobloc EBL 216 2 Introduction This instruction manual contains important information on the safe operation of equipment supplied by Schaudt. Read and always follow the safety instructions. The instruction manual should be kept in the vehicle at all times. Ensure that other users are made aware of the safety regulations. 3 Operation The electronic block is operated exclusively through the connected control and switching board IT ... / LT ... . Operation of the Electrobloc EBL 216 is not required for daily use. 3.1 Switching system on/off ATTENTION! Incorrect settings on the electronic block! Connected devices may be damaged. Therefore, prior to initial start-up: Y F F 12V main switch (on DT/LT ... control and switch panel) Ensure the living area battery is connected. Make sure the AES fuse (Fig. 2, Pos. 2) is only used when the AES refrigerator is connected. Otherwise, the living area battery may be totally discharged. Damage to the battery is possible. ³ Disable battery isolator on the DT/LT ... control and switch panel (see operating instructions of the relevant control and switch panel). ³ After enabling the battery cut-off switch or after changing batteries: 12-Briefly turn on the 12V main switch on the DT/LT ... control and switch panel to start up the consumers. Use the 12 V main switch (see instruction manual of relevant control and switch panel) to switch on/off all the consumers and the control and switch panel. Excluded are: F Side marking lights F Heater F Step F Frost protection valve F AES/compressor refrigerator F Refrigerator control F Wastewater tank heating F Awning light For further information, see the instruction manual of the DT/LT ... control and switch panel . 811.575 BA / EN Date: 26.09.2014 3 Instruction Manual Electrobloc EBL 216 Step switch The supply to the step is protected by a self-resetting fuse. This is why the step switch may only be activated briefly. ATTENTION! Activating the step switch too long results in too high a current! Self-resetting fuse can activate: Y F Only press the step switch briefly. ³ If the self-resetting fuse has triggered, it needs about one minute to reset before the step switch can be pressed again. Operation with solar regulator ATTENTION! No battery buffer function! Damage to connected devices: Y F 3.2 Flat vehicle fuses Self-resetting fuses Do not operate solar regulator without battery connected. System Faults A fault in the power supply system is usually caused by a blown fuse. The following is protected with a self-resetting fuse: F Exit step If a fault has occurred here, the step switch must not be pressed for about one minute. This fuse resets automatically during this period. Please contact our customer service department if you are unable to rectify the fault using the following table. If this is not possible, e.g. if you are abroad, you can have the electronic bloc repaired at a specialist workshop. Please note that the warranty will become void if incorrect repair work is carried out. Schaudt GmbH shall not accept liability for any damages resulting from such repairs. Fault Possible cause Remedy Living area battery is not g during g 230 V charged operation ti (battery (b tt voltage lt constantly below 13.3 13 3 V) No mains voltage Switch on the automatic fuse in the vehicle Defective charger Contact the customer service department Living area battery is overcharged during 230 V operation (battery voltage constantly above 14.5 V) Defective charger Contact the customer service department Starter battery is not charged during 230 V operation (battery voltage constantly below 13.0 V) No mains voltage Switch on the automatic fuse in the vehicle Living g area batteryy is not charged h d during d i mobile bil operation (battery voltage below 13.0 V) 4 Have the mains voltage checked Have the mains voltage checked Defective charger Contact the customer service department Defective alternator Check the alternator No voltage on D+ input Check fuses and wiring Defective electronic block Contact the customer service department Date: 26.09.2014 811.575 BA / EN Instruction Manual Electrobloc EBL 216 Fault Possible cause Remedy The living area battery is overcharged during mobile operation (battery voltage constantly above 14.3 V) Defective alternator Check the alternator The refrigerator does not g mobile work during operation ti No power supply to the refrigerator Check fuse and wiring Defective electronic block Contact the customer service department Defective refrigerator Check the refrigerator Solar charger does not work (power supply and g engine are off)) 12V supply does not work in the living g area Operation of the Electrobloc not possible via DT/LT ... control and switch panel 3.3 Solar panel in (partial) Move solar panel out of shade or covered (snow or shade or clean. dirt) Solar charge regulator not plugged in Plug in solar charge regulator Defective fuse or wiring Check fuse and wiring Solar charge regulator defective Check solar charge regulator 12V main switch for the living g area batteryy is switched off 12V main switch for the living g area batteryy must be switched on Enable battery isolator on the DT/LT ... control and switch panel Disable battery isolator on the DT/LT ... control and switch panel Defective fuse or wiring Check fuse and wiring Defective charger Contact the customer service department Defective charger Contact the customer service department Y If the device becomes too hot due to excessive ambient temperature or lack of ventilation, the charging current is automatically reduced. Nevertheless, always prevent the device from overheating. Y If the automatic shutdown mechanism of the battery monitor is triggered, fully charge the living area battery. Closing down the System ATTENTION! Total discharge. Damage to the living area battery: Y F 811.575 BA / EN Fully charge the living area battery before and after closing down the system. (Connect a vehicle with an 80 Ah battery and a vehicle with a 160 Ah battery to the mains for at least 12 and 24 hours respectively). Date: 26.09.2014 5 Instruction Manual Electrobloc EBL 216 ATTENTION! Permitted input voltages exceeded. Damage to connected consumers: Y F F Shutdown of system up to 6 months Disconnect the living area battery from the 12 V power supply Do not operate any connected Schaudt solar charge regulator without battery. If the battery is going to be changed or removed, first remove ”+ solar cell” connector on the solar charge regulator. ³ Fully charge the living area battery before closing down the system. The living area battery is then protected against total discharge. This only applies if the battery is intact. Follow the instructions of the battery manufacturer. The shut down system requires approx. 4 Ah per month. Disconnect the living area battery from the 12 V power supply if you are not going to use the motorhome for a longer period (during the winter for example). For this, the system has a battery cut-off mechanism that isolates the living area battery from the vehicle. The battery cut-off is enabled on the DT/LT ... control and switch panel (see operating manual of DT/LT ... control and switch panel). ³ Switch off the main switch on the DT/LT ... control and switch panel. ³ Enable the battery cut-off on the DT/LT ... control and switch panel (see operating manual of DT/LT ... control and switch panel). Shutdown period longer than 6 months ³ Fully charge the living area battery before closing down the system. ³ Remove the ”+ solar cell” connector on the solar charge regulator. ³ Remove the clamps from the battery poles. 6 Y The battery alarm is no longer active. Y The frost protection valve opens for certain heater systems when the living area battery is isolated from the Electroblock via the battery cut-off. The boiler and water tank empty when the frost protection valve is open. For more information, see the instruction manual of the heater system. Date: 26.09.2014 811.575 BA / EN Instruction Manual Electrobloc EBL 216 4 Application and Functions in Detail Y This device is intended solely for installation in a vehicle. The EBL 216 Electroblock is the central energy supply device for all 12 V consumers in the electrical system on board the motorhome/caravan. It is normally located inside a cupboard or storage area and is accessible from the front for fuse changes. Solar regulator LR ... Side marking lights Control and display panel DT/LT ... (accessory) Electrobloc EBL 216 230 V AC R Additional charger LAS ... -- (accessory) + Lighting Pump Heater etc. Starter battery -- + Living area battery Fig. 1 Modules System devices 12V consumers On-board power supply system The EBL 216 Electroblock contains: F the complete 12 V distribution F the fuses for the 12 V circuits F A battery monitor module F Other control and monitoring functions A DT or LT ... control and switch panel must be connected for operation. These devices control the electrical functions in the vehicle’s living area, including accessories. There are connections for an additional battery charger and a solar charge regulator. Flat vehicle fuses protect the various circuits. Exceptions here are the step and the frost protection valve. Mains connection 230 V AC ± 10 %, 47 to 63 Hz sinusoidal, protection class I Current-carrying capacity 12 V outputs may be loaded with max. 90% of the rated current of the respective fuse (see also assembly instructions or front panel). 811.575 BA / EN Date: 26.09.2014 7 Instruction Manual Electrobloc EBL 216 4.1 Suitable batteries Battery functions 6-cell lead acid or lead gel batteries, 55 Ah and above Battery charging during mobile operation Simultaneous charging of the starter battery and the living area battery via the alternator, parallel connection of the batteries via a cut-off relay Battery isolation the battery cut-off (enabled on the DT/LT ... control and switch panel) isolates the following connections from the living area battery: F all 12 V consumers F the frost protection valve This prevents slow discharge of the living area battery by the standby current during shutdown of the vehicle (discharge with approx. 4 Ah in month). The batteries can still be charged using the Electrobloc, the alternator, an auxiliary charging unit or the solar charge regulator, even when the battery cut-off switch is switched off. Battery monitor with automatic disconnect The battery monitor of the DT/LT ... control and switch panel constantly monitors the living area battery with dynamic voltage threshold. Lower discharge currents cut off ”earlier” than with larger currents. This provides improved total discharge protection. Monitoring is also performed in the switched-off state. A warning message is displayed below 12.0 V (,depending on current drain). If the voltage of the living area battery sinks further, falling below 10.5 V, the battery monitor immediately switches off all 12 V consumers. The control and switch panel also switches itself off. Only the frost protection valve continues to be powered (so it stays closed). Before switch-off, all switch states are the value of the battery capacity are stored and restored after power-on. If an overload or an insufficiently charged living area battery causes the voltage to fall so low that the automatic disconnector is triggered, any non-essential consumers should be switched off. If need be, the 12 V supply can begin operation for a short time. To do this, switch on the 12 V main switch on the DT/LT ... control and switch panel. However, if the battery voltage remains below 11.0 V, the 12 V power supply can not be turned back on. Fully charge the living area battery as soon as possible. For further information, see ”Battery voltages” in the instruction manual of the relevant DT/LT ... control and switch panel . 8 Date: 26.09.2014 811.575 BA / EN Instruction Manual Electrobloc EBL 216 4.2 Automatic switch function for AES/compressor refrigerator Step fuse Additional functions This relay supplies the AES/compressor refrigerator with power from the starter battery when the vehicle engine is running and the D+ connection is live. An AES/compressor refrigerator is powered by the living area battery when the vehicle engine is not running. The step output is protected by a self-resetting 15A fuse. If a fault occurs, such as overcurrent, the self-resetting fuse interrupts the relevant circuit. After rectification of the fault, the fuse automatically resets after approx. 1 minute. Battery charging with solar charging regulator Maximum permitted charge current 14 A, protected with 15 A Depending on the solar charge regulator used, either only the living area battery is charged or the living area battery and the starter battery. Awning light The power supply to the awning light is automatically interrupted as soon as the engine is started and the D+ connection is live. The awning light can still be used even if the 12 V power supply is switched off. Tank heater The tank heater is enabled via the DT/LT ... control and switch panel. The tank heater can still be used even if the 12 V power supply is switched off. Side marking lights The side marking lights are switch on via the integrated relay. They are powered from the start battery. The relay is activated via terminal 58. 5 Maintenance The Electrobloc requires no maintenance. 811.575 BA / EN Cleaning Clean the electronic block with a soft, slightly damp cloth and mild detergent. Never use spirit, thinners or similar substances. Do not allow liquids to enter the electronic block. E No part of this manual may be reproduced, translated or copied without express written permission. Date: 26.09.2014 9 Instruction Manual Electrobloc EBL 216 Appendix A EC Declaration of Conformity Schaudt GmbH hereby confirms that the design of electronic block EBL 216 complies with the relevant regulations. The original EC Declaration of Conformity is available for reference at any time. Manufacturer Address B Switch panel Schaudt GmbH, Elektrotechnik & Apparatebau Planckstraße 8 88677 Markdorf Germany Special fittings/accessories Schaudt DT .../LT ... switch panel (required for operation) Additional charger Schaudt battery charger LAS ... with max. 14 A charge currency, including suitable connection cable (MNL). Solar charge regulator Schaudt Solar-charge regulator type LR ... for solar modules with an overall currency of 14 A with 3-pole connection plug and connection cable C Customer service address Customer service Schaudt GmbH, Elektrotechnik & Apparatebau Planckstraße 8 D-88677 Markdorf tel.: +49 7544 9577-16 e--mail: [email protected] web: www.schaudt-gmbh.de Send in the device Returning a defective device: ³ Fill in and enclose the fault report, see Appendix D. ³ Send it to the addressee (free of charge). 10 Date: 26.09.2014 811.575 BA / EN Instruction Manual Electrobloc EBL 216 D Fault report In the event of damage, please return the defective device together with the completed fault report to the manufacturer. Device type: Article no.: Vehicle: _______________________ _______________________ Manufacturer: _______________________ Model: _______________________ Own installation? Yes - No Upgrade? Yes - No - Following fault has occurred (please tick): - Electrical consumers do not work -- which? (please specify below) - Switching on and off not possible - Persistent fault - Intermittent fault/loose contact Other remarks: 811.575 BA / EN Date: 26.09.2014 11 Instruction Manual Electrobloc EBL 216 E Mains connection Technical data 230 V AC ±10%, 47 to 63 Hz sinusoidal, protection class I Current consumption 160 mA Standby current from Living area battery Depending on the control and switch panel: approx. 5 -- 20 mA, plus consumption of controller electronics of refrigerator Measurement approx. 10 minutes after disconnection from the mains: F F F F F D+ loading Current-carrying capacity Battery charging via solar charge regulator Battery charging during mobile operation Battery monitor 12 not connected to mains 12.6 V battery voltage Battery isolation not enabled Control and switch panel lighting off 12V main switch off Loading of the D+ output of the alternator by the Electroblock approx. 1 mA without current consumption on D+ point 12V outputs A maximum of 90% of the nominal current of the relevant fuse may be drawn. Frost ventilation valve output max. 0.1 A D+ point max 1 A Maximum permitted charge current 14 A, protected with 15 A Simultaneous loading of living area battery by alternator Batteries connected in parallel via a cut-off relay Cut-off voltage approx. 10.5 V Minimum battery voltage for switch-on via the 12 V main switch on the control and switch panel: approx. 11.0 V Date: 26.09.2014 811.575 BA / EN Instruction Manual Electrobloc EBL 216 F Design 2 3 4 6 5 7 8 R 1 16 Fig. 2 1 2 3 4 5 6 7 8 9 15 14 13 12 11 9 10 Design, Electroblock EBL 216 (front) Assembly flaps AES refrigerator fuse Flat vehicle fuses Self resetting step fuse (internal) Connection block solar regulator (measurement signal) Connector, DT .../LT ... control and switch panel Mains connector Connector block, refrigerator supply D+, Battery sensor/control lines Connector, DT .../LT ... control and switch panel 10 Connector block, light, refrigerator control, D+, TV, Side marking lights, tank heater 11 Connection block, awning light, pump, heater, light 12 Connection block, solar regulator (supply) 13 Connection block, refrigerator, step 14 Connection block, additional charger 15 Connection block, refrigerator supply 16 Housing Starter Living area Battery Negative Battery + 3 Fig. 3 1 2 -- + 2 1 Design, electronic block EBL 216 (rear) Connection, living area battery Connection, earth 811.575 BA / EN 3 Date: 26.09.2014 Connection, starter battery 13 Instruction Manual Electrobloc EBL 216 G Block diagram/connection diagram 25A Molex Minifit SR 2 x Block 1 2 2 + Auxiliary charging unit 1 Negative auxiliary charging 1 A1 Charging relay B1 A7 Mains 230V~ 50Hz socket D A3 R Schaudt solar charger regulator type LRS... with connection cable D+ Booster 3 2 3 2 Negat. 1 1 Negative LAB * MNL--- --- Socket 4 x Block 9 1 1 2A 4 4 60A Shunt A + SB E20--- --- 3F --- --- screw terminal 60A + SB 60A + LAB A21 MNL socket cap 3 x + LAB The negative pole of the living area battery must be connected externally to the negative pole of the starter battery. A2 230V AC Block 6 Battery cutoff relay 3 3 2 2 15A D+ * base D+ input + LAB sensor 2A Negative LAB sensor * active ground Lumberg MSFQ/0 12x at block 10 control panel B 8 8 Negative sensor LAB 11 11 + SB 7 Shunt battery Signal LAB 1 1 7 Signal SB 2 2 6 6 Shunt consumer 3 3 10 10 + LAB sensor 4 4 5 2 5 Mains indicator 2 MS relay 1 On 1 1 MS relay 1 Off 4 4 MS relay 2 On E MS relay 1 60A Solar module A Lumberg MSFQ/0 4 x Block 7 E MS relay 2 60A Lumberg MSFQ/0 10 x A at block 8 control panel Signal Solar SB 6 Signal Solar WB 7 A Module HS 100 3 1 4 Pump 2 nc 5 5 PolySwitch R B 8 nc 10 10 C 15A 9 Important! The fuse is only used for the AES refrigerator! 10A/max. 20A LAB = living area battery SB = starter battery Switching stage 2A 15 x Part 2 + Side marking lamps 2 2 13 + Spare 3 --- --- Spare 10 3 10 Input Side marking lamps 1 + Refrigerator 1 1 Negative step + Step 7,5A 5A 3 + SB refrigerator C B 9 + Heater 7 --- --- Heater 6 + Pump 1 Negative pump (switched) 3 3 + Light1 2 2 --- --- Light1 1 4 Frost protection valve heater system MNL--- Socket 15 x Part 1 Block 6 6 + Light2 6 2 11 --- --- Light2 11 4 15 15 + Refrigerator control 4 4 D+ base 9 9 + Light 3 --- --- Tank heater 8 14 10A 20A 1 6 10A 1 1 nc 3 7 10A D 1 9 10A --- --- Side marking lamps 13 3 MNL--- --- Socket 9 x Block 5 8 + Awning light 8 5 --- --- Awning light 5 Awning light 7,5A Block 6 4 3 2 Negative refrigerator Molex Minifit SR 3 x Block 3 2 2 Negative SB refrigerator Refrigerator AES 15A *** 5A 4 2 5A Switching stage MNL--- Socket 12 + Lighting 9 Negative lighting Molex Minifit SR 4 x Block 2 Tank heater 2 nc 8 nc 9 3 MS relay 2 Off 12 9 6 7 Tank heater 3 D+ 1 Frost protection valve 4 3 3 8 --- --- Light 3 14 + Tank heater 7 7 12 12 + TV 5 5 --- --- T V Circuit board KPL EBL 226 14 Date: 26.09.2014 811.575 BA / EN ">
/
Ladda ner
Bara en vänlig påminnelse. Du kan visa dokumentet här. Men viktigast av allt, vår AI har redan läst det. Den kan förklara komplexa saker på ett enkelt sätt, svara på dina frågor på vilket språk som helst och hjälpa dig att snabbt navigera även de längsta eller mest komplicerade dokumenten.
Annons