Omron C120, SYSMAC C1000H, SYSMAC C200H, SYSMAC C500 System Manual
Below you will find brief information for C120 SIO27, C200H RT001, C500 RT001. These Remote I/O Systems are designed to simplify wiring in industrial environments, allowing control of I/O devices located at significant distances from the CPU. The Optical Remote I/O System employs optical fiber cables, ensuring high-speed data transmission and improved noise immunity, essential for reliable operation in demanding industrial settings. It supports various programmable controller systems.
Advertisement
Advertisement
Optical Remote I/O System Manual Revised December 1999 No. 6182 OMRON Corporation Read and Understand this Manual Please read and understand this manual before using the product. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NONINFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 1 No. 6182 Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this manual. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 2 No. 6182 Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this manual is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 3 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. ! WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. ! Caution Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage. ! OMRON Product References All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense. The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for anything else. Visual Aids The following headings appear in the left column of the manual to help you locate different types of information. Note Indicates information of particular interest for efficient and convenient operation of the product. 1, 2, 3... 1. Indicates lists of one sort or another, such as procedures, checklists, etc. OMRON, 1990 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication. v vi TABLE OF CONTENTS PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating Environment Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Application Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-2 Remote I/O Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optical Remote I/O Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 2 System Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 Basic System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multilevel Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C20, P-type, and K-type Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C120 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C500 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C1000H and C2000H Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C200H System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Combined Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 3 Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-2 3-3 3-4 Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O Link Unit Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unit Number and I/O Word Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O Word Allocation Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 4 Unit Components and Switch Settings . . . . . . . . . . . . . . . 4-1 4-2 4-3 4-4 Remote I/O Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O Link Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optical I/O Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 5 System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5-2 5-3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optical Fiber Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 6 I/O Response Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 6-2 6-3 6-4 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C500 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C1000H and C2000H Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C200H Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii TABLE OF CONTENTS SECTION 7 Error Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 7-2 7-3 Self-diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SR and AR Area Flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Locating Transfer Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendices A B C D Standard Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Supply Wiring Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the C200H-RM001-PV1 with CS1-series PCs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii About this Manual: Basic OMRON PC Systems can be expanded to include Optical Remote I/O Systems. These flexible, distributed control systems which use optical fiber cable to provide rapid data transmission over long distances, free from external noise. This manual has been prepared to explain how to incorporate Optical Remote I/O Systems into C120, C200H, C500, C1000H, and C2000H PC Systems. It provides the necessary information, such as system configuration, settings, and I/O word allocation, for connecting Remote I/O Master Units, Remote I/O Slave Units, I/O Link Units, and/or Optical I/O Units. Before attempting to install or operate an Optical Remote I/O System, be sure to thoroughly familiarize yourself with the information contained herein. Section 1 introduces Optical Remote I/O Systems and describes their advantages and characteristics. Section 2 describes the components that go together to construct an Optical Remote I/O System and the factors required to design a System. Section 3 describes the LR area used in data transfer between the PCs, the method used to allocate it to the PCs, and the polling process used to actually transfer data. Section 4 provides details on Optical Remote I/O Systems and the main Units used to build these Systems. Parts of the Units, switch setting, and examples of switch settings are provided. Section 5 provides details on Unit dimensions and optical fiber cable. Section 6 offers details on response times. Section 7 describes error indications and error processing. Both indicator lights and dedicated error– related flags are provided. Appendix A provides a list of the basic specifications and complete model numbers of products used in Optical Remote I/O Systems. Appendix B provides technical specifications. ! WARNING Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given. ix PRECAUTIONS This section provides general precautions for using the Optical Remote I/O System and related devices. The information contained in this section is important for the safe and reliable application of the Optical Remote I/O System. You must read this section and understand the information contained before attempting to set up or operate the Optical Remote I/O System. 1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating Environment Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Application Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi 3 Safety Precautions 1 Intended Audience This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). • Personnel in charge of installing FA systems. • Personnel in charge of designing FA systems. • Personnel in charge of managing FA systems and facilities. 2 General Precautions The user must operate the product according to the performance specifications described in the relevant manuals. Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms. This manual provides information for programming and operating the System. Be sure to read this manual before attempting to use the System and keep this manual close at hand for reference during operation. ! WARNING It is extremely important that the Optical Remote I/O System be used for the specified purpose and under the specified conditions, especially in applications that can directly or indirectly affect human life. You must consult with your OMRON representative before applying the Optical Remote I/O System to the above-mentioned applications. 3 Safety Precautions ! WARNING Do not attempt to take any Unit apart while the power is being supplied. Doing so may result in electric shock. ! WARNING Do not touch any of the terminals or terminal blocks while the power is being supplied. Doing so may result in electric shock. ! Caution Tighten the screws on the terminal block of the AC Power Supply Unit to the torque specified in the operation manual. The loose screws may result in burning or malfunction. ! Caution Execute online edit only after confirming that no adverse effects will be caused by extending the cycle time. Otherwise, the input signals may not be readable. ! WARNING Do not attempt to disassemble, repair, or modify any Units. Any attempt to do so may result in malfunction, fire, or electric shock. ! WARNING Provide safety measures in external circuits (i.e., not in the Programmable Controller), including the following items, in order to ensure safety in the system if an abnormality occurs due to malfunction of the PC or another external factor affecting the PC operation. Not doing so may result in serious accidents. xii 5 Application Precautions • Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures must be provided in external control circuits. • The PC will turn OFF all outputs when its self-diagnosis function detects any error or when a severe failure alarm (FALS) instruction is executed. As a countermeasure for such errors, external safety measures must be provided to ensure safety in the system. • The PC outputs may remain ON or OFF due to deposition or burning of the output relays or destruction of the output transistors. As a countermeasure for such problems, external safety measures must be provided to ensure safety in the system. 4 Operating Environment Precautions ! Caution Do not operate the control system in the following locations: • Locations subject to direct sunlight. • Locations subject to temperatures or humidity outside the range specified in the specifications. • Locations subject to condensation as the result of severe changes in temperature. • Locations subject to corrosive or flammable gases. • Locations subject to dust (especially iron dust) or salts. • Locations subject to exposure to water, oil, or chemicals. • Locations subject to shock or vibration. ! Caution Take appropriate and sufficient countermeasures when installing systems in the following locations: • Locations subject to static electricity or other forms of noise. • Locations subject to strong electromagnetic fields. • Locations subject to possible exposure to radioactivity. • Locations close to power supplies. ! Caution 5 The operating environment of the Optical Remote I/O System can have a large effect on the longevity and reliability of the system. Improper operating environments can lead to malfunction, failure, and other unforeseeable problems with the System. Be sure that the operating environment is within the specified conditions at installation and remains within the specified conditions during the life of the System. Application Precautions Observe the following precautions when using the Optical Remote I/O System. ! WARNING Always heed these precautions. Failure to abide by the following precautions could lead to serious or possibly fatal injury. • Always ground the system to 100 Ω or less when installing the Units. Not connecting to a ground of 100 Ω or less may result in electric shock. • Always turn OFF the power supply to the PC before attempting any of the following. Not turning OFF the power supply may result in malfunction or electric shock. • Mounting or dismounting I/O Units, CPU Units, Memory Units, or any other Units. xiii 5 Application Precautions • Assembling the Units. • Setting DIP switches or rotary switches. • Connecting cables or wiring the system. • Connecting or disconnecting the connectors. ! Caution Failure to abide by the following precautions could lead to faulty operation of the Optical Remote I/O System, or could damage the PC or PC Units. Always heed these precautions. • Fail-safe measures must be taken by the customer to ensure safety in the event of incorrect, missing, or abnormal signals caused by broken signal lines, momentary power interruptions, or other causes. • Always use the power supply voltages specified in this manual. An incorrect voltage may result in malfunction or burning. • Take appropriate measures to ensure that the specified power with the rated voltage and frequency is supplied. Be particularly careful in places where the power supply is unstable. An incorrect power supply may result in malfunction. • Install external breakers and take other safety measures against short-circuiting in external wiring. Insufficient safety measures against short-circuiting may result in burning. • Do not apply voltages to the Input Units in excess of the rated input voltage. Excess voltages may result in burning. • Do not apply voltages or connect loads to the Output Units in excess of the maximum switching capacity. Excess voltage or loads may result in burning. • Disconnect the functional ground terminal when performing withstand voltage tests. Not disconnecting the functional ground terminal may result in burning. • Be sure that all the mounting screws, terminal screws, and cable connector screws are tightened to the torque specified in this manual. Incorrect tightening torque may result in malfunction. • Leave the label attached to the Unit when wiring. Removing the label may result in malfunction if foreign matter enters the Unit. • Remove the label after the completion of wiring to ensure proper heat dissipation. Leaving the label attached may result in malfunction. • Double-check all wiring and switch settings before turning ON the power supply. Incorrect wiring may result in burning. • Mount Units only after checking terminal blocks and connectors completely. • Be sure that the terminal blocks, Memory Units, expansion cables, and other items with locking devices are properly locked into place. Improper locking may result in malfunction. • Check the user program for proper execution before actually running it on the Unit. Not checking the program may result in an unexpected operation. • Confirm that no adverse effect will occur in the system before attempting any of the following. Not doing so may result in an unexpected operation. • Changing the operating mode of the PC. • Force-setting/force-resetting any bit in memory. • Changing the present value of any word or any set value in memory. • Resume operation only after transferring to the new CPU Unit the contents of the DM Area, HR Area, and other data required for resuming operation. Not doing so may result in an unexpected operation. • Do not pull on the cables or bend the cables beyond their natural limit. Doing either of these may break the cables. • Do not place objects on top of the cables or other wiring lines. Doing so may break the cables. xiv Application Precautions 5 • Use crimp terminals for wiring. Do not connect bare stranded wires directly to terminals. Connection of bare stranded wires may result in burning. • When replacing parts, be sure to confirm that the rating of a new part is correct. Not doing so may result in malfunction or burning. • Before touching a Unit, be sure to first touch a grounded metallic object in order to discharge any static built-up. Not doing so may result in malfunction or damage. xv SECTION 1 Introduction 1-1 1-2 Remote I/O Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optical Remote I/O Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Section Remote I/O Systems 1-1 1-1 Remote I/O Systems Assembly lines are often extremely long, making it difficult if not impossible to wire all I/O devices directly from CPU Racks or Expansion I/O Racks. A Remote I/O System can be used to solve this problem. In a Remote I/O System, a Rack can be located farther from the CPU Rack than is possible with Expansion I/O Racks connected directly to the CPU Rack. By locating a Rack farther from the CPU Rack, a Remote I/O System eliminates the time and mess in wiring (or changing wiring) to many devices that are separated from the CPU Rack. Although all I/O points must ultimately be wired individually, the question is one of distance: Do you want to wire dozens of terminals all the way across a factory complex or do you want to run a single cable for most of the distance and then wire individual terminals locally? The following diagram illustrates how a simple Remote I/O System would be set up. Slave Racks, described below, are controlled by the CPU through the Master. The dotted circles show the devices that would be controlled through the Units on each Rack. Master Slave CPU Rack Slave Rack Processing machine Assembly line Processing machine Sensor Processing machine Processing machine Sensor Sensor Slave Rack Slave Wiring distance could also be reduced by placing an independent CPU Rack near every location that required control, but in doing so, each PC would have to be programmed independently and the activities of all the PC programs would need to be coordinated, a very difficult job. Here too, a Remote I/O System simplifies the task by allowing a single CPU, and thus a single program, to integrate control of the entire process. A Remote I/O System thus has these two advantages: Racks can be located a greater distance from the CPU Rack and coordinating control actions is simplified because all control is exerted by one program. A third advantage of Remote I/O Systems is reduced noise interference. This is the result of the single cable that replaces the otherwise numerous wires that would be required all the way from the CPU and Expansion I/O Racks to the I/O devices. A Remote I/O System directly involves only one PC and the program in it. Through it, a large number of I/O points can be controlled a greater distance from 2 Section Remote I/O Systems 1-1 the PC. This is achieved by mounting a Remote I/O Master Unit to the CPU Rack to control I/O points located possibly many kilometers away. Each Master serves as a ‘switching point’ for controlling all of the I/O points accessed through it. These I/O points are accessed through the Master, not controlled by it. All I/O control comes from the program in the CPU. More than one Master can be mounted to a single PC, with each Master forming the starting point of a Remote I/O Subsystem, i.e., a Remote I/O Subsystem includes one Master plus all of the Remote I/O Units controlled through it. The Remote I/O Units that can be included in each Subsystem depend on the specifications of the Master. Masters are available either with optical or wire specifications. Optical Remote I/O Systems transfer data through optical fiber cables to enable the greatest transmission distance and the greatest resistance to electrical noise. Wired Remote I/O Systems use wire cables which don’t offer as great a distance as Optical Subsystems, but do greatly reduce the burden of wiring remote I/O and afford greater resistance to noise than independently wired I/O points. Both types of Master can be mounted to the same PC to meet specific distance and noise-resistance requirements. PC Master on Rack PC Optical and Wired Masters on Rack Remotely Controlled I/O Devices Label printer Glue coater Wired Subsystem Auto welder Polisher Optical Subsystem Conveyer Packing machine All Remote I/O Systems consist of at least one Remote I/O Master Unit connected in series to one or more Units accessed through it. One of these Units that is common to most Remote I/O Systems is a Remote I/O Slave Unit. A Master is mounted to the CPU Rack or an Expansion I/O Rack; a Slave is mounted to a Backplane to form what is called a Slave Rack. To a Slave Rack is mounted the same other Units as those mounted to the CPU or Expansion I/O Rack, with only a few exceptions (e.g., Link Units other than Slaves cannot be mounted to Slave Racks). The advantage of a Slave Rack is that it can be located a considerable distance from the CPU Rack with the only connection required being a cable running from the Master to the Slave. The actual distance a Slave Rack can be removed from the Master, as well as the other Units used to configure a Remote I/O System, depends on the type of Remote I/O System being used. Collectively, all of the Units connected in a Remote I/O System are referred to as Remote I/O Units. This manual describes Optical Remote I/O Systems. Wired Remote I/O Units are described in the Wired Remote I/O System Manual. 3 Section Optical Remote I/O Systems 1-2 1-2 Optical Remote I/O Systems Optical Remote I/O Systems are flexible, distributed control systems which can be customized as necessary by adding or eliminating various Units. They are easy to design and adjust and have a very short downtime even in the unlikely event of system failure. Optical Remote I/O Systems consist of one or more Remote I/O Master Units together with one or more of the following Units: I/O Link Units, I/O Slave Unit, and Optical I/O Units. PC I/O Units Slave I/O Link Unit I/O bus Master PC Optical I/O Unit An I/O Link Unit mounted to a CPU Rack or an independent I/O Link Rack is used to create an I/O Link between two CPUs. An I/O Link allows one CPU to directly input and/or output one or two words of data from and to another CPU. This enables coordination of CPU activities. Although this is an exception to the basic ‘one-program’ concept of Remote I/O Systems, it can be very effective when one part of an operation requires a separate program but also requires integration with another PC. With the smaller (e.g., P-type and K-type) PCs, I/O Links are also the only way to connect to a Remote I/O System. An I/O Link can also be set up as the only element of an Optical Remote I/O System, i.e., without any Optical I/O Units or Slave Racks. Such a System would be a like a PC Link System on a very limited scale, but it would employ I/O bits in the IR area and not the LR area. An Optical I/O Unit is used when it is necessary to control only a few I/O points in one location. It is not mounted to a Rack; rather, it is located by itself in series with the rest of the Units in the System. In this respect, an Optical I/O Unit is the Optical System equivalent of a Remote Terminal. Unlike a Remote Terminal, however, an Optical I/O Unit has fixed I/O terminals, not replaceable relays. In appearance, it looks much like an I/O Unit or Special I/O Unit. A Remote I/O Subsystem consists of a single Remote I/O Master Unit and all Remote I/O Units controlled through it. In this manual, the term “Remote I/O Subsystem” always refers to an Optical System unless specifically designated as a Wired System. For convenience, Remote I/O Master Units and Remote I/O Slave Units are referred to respectively as simply “Masters” and “Slaves”. These terms, as well, always refer to Optical Units unless otherwise specified. The term “Slave Rack” is used to refer to a Backplane with a Slave mounted to it. “PC” always means Programmable Controller. C500 Masters and C500 Slaves are used for the C500, C1000H, and C2000H. C500 Masters and C500 Slaves can also be used for the C120, although a C120 Master and C120 Slave are available Features of Optical Remote I/O Systems 4 An Optical Remote I/O System provides a number of advantages, as indicated in the following table. Section Optical Remote I/O Systems 1-2 Advantages of Optical Remote I/O Systems Reduced wiring burden and easier wiring changes Greater transmission distance from CPU Rack Coordination of control facilitated by use of a single program I/O Links enable direct transfer of data between PCs Rapid data transmission High responsiveness and fidelity Free from the adverse effects of external noise Optical fiber cable is used for communication lines. As a result, wiring is significantly simplified and the system can be easily expanded as necessary. Either All-plastic Fiber (APF), Plastic-clad Fiber (PCF), or Quartz Crystal (AGF) can be used for the optical fiber cables in a an Optical Remote I/O System. APF cable is especially instrumental in simplifying wiring and reducing cost. Terminology A variety of basic Systems and Subsystems can be constructed and combined in many ways to meet a wide range of control requirements. Throughout this manual, particular terms are used to refer to these basic systems, and they are defined as follows. A Control System is the extended system, including all external devices such as stepping motors, mechatronic modules, and control components (solenoids, sensors, switches, etc.). A PC System is a system which includes a Programmable Controller (PC) and all it controls up to, but not including, any external devices. A Remote I/O System includes all the Optical and Wired Remote I/O subsystems under the control of a single PC. These systems can perform distributed control actions, such as remote operation of several large machines, by executing a program in the memory of a single PC’s CPU. Model numbers have been shortened. For example, a C200H-RT001 Remote I/O Slave Unit is called simply a “C200H Slave.” See Appendix A for a complete list of all products covered in this manual, along with their model numbers. 5 SECTION 2 System Design 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 Basic System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multilevel Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C20, P-type, and K-type Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C120 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C500 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C1000H and C2000H Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C200H System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Combined Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Section Basic System 2-1 2-1 Basic System Some basic Systems of Remote I/O Units (i.e., Masters and Slaves), I/O Link Units, and Optical I/O Units are shown in the following table. ! Caution Unit Connection Master Slave Slave Master I/O Link Unit I/O Link Unit Master Optical I/O Unit Optical I/O Unit Master Slave I/O Link Unit* Optical I/O Unit Master Slave Slave Optical I/O Unit I/O Link Units cannot be connected to Slaves in C200H Systems. One Master is always necessary to connect Slaves, I/O Link Units, and Optical I/O Units. Slaves, I/O Link Units, and Optical I/O Units can be used in combination. Connect all Slaves, I/O Link Units, and Optical I/O Units in series starting from the Master. The only condition that must be met in regard to the order of connecting Remote I/O Units is that the Master be on one end of the System and I/O Link Units cannot be connected after C200H Slaves. There are three types of Master: One for the C120, one for the C500 (which is also used for the C120, C1000H, and C2000H), and one for the C200H. Two type of Slaves are available: One for the C500, C1000H, and C2000H, and one for the C200H. There are no Masters or Slaves available for the C20, P-type PCs, or K-type PCs. The I/O Link Unit also comes in three types: the C20 I/O Link Unit for the C20, K-type PCs, and P-type PCs, the C120 I/O Link Unit for the C120, and the C500 I/O Link Unit for the C500, C1000H, and C2000H. There is no I/O Link Unit for the C200H. Mounting Units C500 Slaves are mounted to the I/O Interface Unit’s position on the Slave Rack and connected in series to the Master. C200H Slaves are mounted to the right side of a Backplane where the Power Supply normally goes. A Power Supply is normally built into the Slave. C200H and C500 Masters can be mounted to any slot on the CPU Rack or Expansion I/O Rack. C120 Masters are mounted to C120-SIO27 Remote I/O Rack only. The C500 I/O Link Unit is mounted to any slot on a C500, C1000H, or C200H CPU Rack or Expansion I/O Rack and the C120 I/O Link Unit is mounted to the C120-SIO23 I/O Link Rack. The C20 I/O Link Unit is free-standing and is connected via a Connecting Cable to the C20, K-type, or P-type CPU or Expansion I/O Unit. Connecting Wired Subsystems 8 Wired Subsystems and Optical Subsystems can be connected together in the same PC System as described in 2-2 Multilevel Systems. Any Wired Units used (e.g., Wired Slaves or Remote Terminals) must be counted against the total number of Units connectable in any System, as shown below. Section Basic System Maximum Number of Connectable Remote I/O Units Item C120/C500 Masters per PC Slaves per Master Slaves per PC Total Slaves, I/O Link Units, and Optical I/O Units per Master 4 2 8 32 Connection words per Master 16 words C1000H/ C2000H 2-1 C200H* 8 2 8 – 16 5 64 (Repeater Unit required for more than 32 Units.) 32 words *In C200H Systems, the maximum number of connectable Units and words is the same regardless of whether one or two Masters are used. ! Caution Total I/O Points In C1000H and C2000H Systems, the CPU determines the number of connected Slaves from the assigned Unit numbers, as shown in the following table. It is thus important to always set Unit numbers in order starting from #0 so that the number of Units that can be used in the System is not limited. Largest Unit No. Set Number of Units Connected 0 or 1 2 2 or 3 4 4 or 5 6 6 or 7 8 The total number of I/O points in the System must not exceed the number of I/O points provided by the CPU to which the Master is mounted. The number of I/O points in a C1000H System can be increased up to 2,048, and the number of points in a C200H System can be increased to 1,680, by including Remote I/O Units and the necessary related Units. The total number of I/O points available from the CPU Rack or Expansion I/O Racks, however, is 1,024. CPU C2000H C1000H C500 C200H C120 Maximum Number of I/O Points 2,048 1,024 (expandable up to 2,048 points) 512 336 (expandable to 1,680 points) 256 Total number of I/O points in System = Total number of I/O points on CPU and Expansion I/O Racks + Total number of I/O points on Optical Slave Racks + Total number of points on I/O Link Units + Total number of points on Optical I/O Units + Total number of I/O points in Wired Subsystems, i.e., Wired Slave Racks and Remote Terminals 9 Section Multilevel Systems 2-2 2-2 Multilevel Systems There is no reason that a Remote I/O System must remain restricted to one Master or to either wired or optical communications. PCs support multiple Masters, some of which can be Wired and some of which can be Optical. If there is more than one Master mounted under the control of a single CPU, each Master forms the beginning of a Remote I/O Subsystem. Although the number of Subsystems supported by each PC is limited, each Subsystem can be considered independently from the others as long as the total capacity of the PC is not exceeded. It is important to note that although both Wired and Optical Masters can be controlled by the same CPU, Optical and Wired Remote I/O Units cannot be combined in the same Subsystem, i.e., Optical Masters can be connected only to Optical Slaves, Optical I/O Units, and I/O Link Units; Wired Masters can be connected only to Wired Slaves, Remote Terminals, and I/O Terminals. In the example on the next page, two CPU Racks are used. The one in the upper left corner controls two Remote I/O Subsystems, one Wired and one Optical. The Optical System contains an I/O Link to the other CPU Rack (at the right), which has one Remote I/O Subsystem controlled by it. The Optical I/O Unit, Slave Rack, and Expansion I/O Rack beneath the CPU Rack at the right are controlled through the Optical Master on this CPU Rack. This Optical Master also connects the CPU to the C20 I/O Link Unit. Another aspect of Remote I/O Systems demonstrated by this diagram is the presence of Expansion I/O Racks, both connected to a CPU Rack and to Slave Racks. Although normally not shown in system diagrams for Link Systems, Expansion I/O Racks can be used to increase the number of I/O Units mountable at any one location. 10 Section C120 Systems C200H CPU Rack Wired Master 2-4 C200H Optical Slave Rack Wire cable Optical Slave Optical Master Optical cable Wire cable Optical cable Wire cable C2000H CPU Rack Optical Master C200H Wired Slave Rack Expansion I/O Rack Wired Slave Wire cable Expansion I/O Rack I/O Link Unit Optical cable Wire cable Optical I/O Unit C20 I/O Link Unit C20, K-type or P-type PC C500 Wired Slave Rack Optical cable Wired Slave Optical cable Wire cable C200H Optical Slave Rack Remote Terminal Wire cable Wire cable Optical Slave Expansion I/O Rack Remote Terminal 2-3 C20, P-type, and K-type Systems The C20, P-type PCs, and K-type PCs can be connected to Remote I/O System only through the C20 I/O Link Unit. They can thus send data to and receive data from the PC that controls the Remote I/O System, but they cannot control their own Remote I/O System. These PCs are therefore included in some of the other system configurations, but none are provided for them here. 2-4 C120 Systems Up to four Masters can be connected to any one PC and up to two Slaves can be connected to any one Master. In C120 System, either C120 Masters or C500 Masters can be used. Which Master is used makes no difference to the operation of the Remote I/O System. The C120 Master 3G2A6-RM001-(P)E is mounted to the upper slot of the Remote I/O Rack 3G2C4-SI027-E (100 VAC). 11 Section C120 Systems 2-4 The C500 Master C500-RM001-(P)V1 is mounted to a C500 Expansion I/O Rack (connected to the C120 CPU). Slaves can be mounted only to the C500 Expansion I/O Rack, and they must be mounted to the leftmost slot of the Rack. The C120 provides 256 I/O points. This means that the total number of points used for I/O Units, I/O Link Units, and Optical I/O Units must be 256 or less. If, for example, 256 points are controlled by one Master connected to a C120, no more Masters can be employed for that C120, and no more I/O points can be added to the Remote I/O System. Refer to 5-2 Optical Fiber Cable for maximum cable lengths. Example 1 The three Systems in this example show the different ways the basic Optical Remote I/O Units can be arranged. The first System uses only Slaves, as would be done if a more I/O points were required in each location than could be provided by Optical I/O Units or if future expandability was necessary. The second System uses only Optical I/O Units to provide minimal I/O points at each location. The third System incorporates both Slaves and Optical I/O Units, as would be necessary in many Systems to provide the specific number of points needed at different types of control locations. Here, the first System uses a C500 Master on a C500 Expansion I/O Rack; the other two Systems, a C120 Master on a C120 Remote I/O Rack. Either of these Systems could be changed to use the other type of Master without affecting Remote I/O System Operation. The difference would be the number of I/O points that could be provided from the Rack containing the Master. For limitations in Unit connections, refer to Maximum Number of Connectable Remote I/O Units under 2-1 Basic System. Master and Slaves C120 CPU Rack Optical Fiber Cable (APF/PCF) C500 Slave 3G2A5-RT002-(P)EV1 C500 Slave Racks C500 Master 3G2A5-RM001-(P)EV1 C500 Slave 3G2A5-RT001-(P)EV1 12 Section C120 Systems 2-4 Optical I/O Units C120 CPU Rack Optical Fiber Cable (APF/PCF) C120 Remote I/O Rack C120 Master 3G2A6-RM001-(P)E Optical I/O Units Optical I/O Units 32 Units max. Any I/O Units on the CPU Rack or Remote I/O Rack must be included in this total. Slaves and Optical I/O Units C120 Rack Optical Fiber Cable (APF/PCF) C120 CPU Remote I/O Rack C120 Master 3G2A6-RM001-(P)E Optical I/O Units Slave Rack C500 Slave 3G2A5-RT002-(P)EV1 Optical I/O Units 32 Units max. Example 2 I/O Link Units Not only the C20 and C120 I/O Link Units but also the C500 I/O Link Unit can be connected to the System. A maximum of 256 points on I/O Link Units can be connected when all of these I/O Link Units are set to 16 points, i.e., 16 I/O Link Units per Master. (The C20 I/O Link Unit has no setting for the number of I/O points and is thus limited to 32 points.) Optical Fiber Cable (APF/PCF) C120 CPU Rack To I/O Link Unit C120 CPU Rack C120 Remote I/O Rack C120 Master 3G2A6-RM001-(P)E C120 I/O Link Rack C120 I/O Link Unit 3G2A6-LK010-(P)E C20, K-type or P-type PC C20 I/O Link Unit 3G2C7-LK011-(P)E 13 Section C500 Systems 2-5 Example 3 I/O Link Units, Slaves, and Optical I/O Units Any combination of I/O Link Units, Slaves, and Optical I/O Units may be connected. Optical Fiber Cable (APF/PCF) C120 CPU Rack C120 CPU Rack Slave Rack C120 Remote I/O Rack C120 I/O Link Rack C120 Master 3G2A6-RM001-(P)E C120 I/O Link Unit 3G2A6-LK010-(P)E C500 Slave 3G2A5-RT002-(P)EV1 2-5 Optical I/O Units C500 Systems Up to four Masters can be mounted on the same PC. C500 PCs provide 512 I/O points. This means that the total number of points used for I/O Units, I/O Link Units, and Optical I/O Units must be 512 or less. If, for example, 512 points are controlled by one Master connected to a C500, no more Masters or I/O points can be employed for that C500. Refer to 5-2 Optical Fiber Cable for maximum cable lengths. For limitations in Unit connections, refer to Maximum Number of Connectable Remote I/O Units under 2-1 Basic System. Example 1 Master and Slaves Optical Fiber Cable (APF/PCF) C500 CPU Rack C500 Master 3G2A5-RM001-(P)EV1 C500 Slave 3G2A5-RT001-(P)EV1 14 C500 Slave 3G2A5-RT002-(P)EV1 Slave Racks Section C500 Systems 2-5 Example 2 Optical I/O Units Up to 64 Optical I/O Units can be connected to one Master on a C500. If more than 32 Units are connected to the same Master, a Repeater Unit must be installed after the first 32 Units. Optical Fiber Cable (APF/PCF) C500 CPU Rack C500 Master 3G2A5-RM001-(P)EV1 Optical I/O Units Repeater Unit 3G5A2-RPT01-(P)E 32 Units Optical I/O Units 32 Units max. Example 3 Slaves and Optical I/O Units Up to 64 Units, consisting of Optical I/O Units and up to two Slaves, can be connected to one Master on a C500. If more than 32 Units are connected to the same Master, a Repeater Unit must be installed after the first 32 Units. The Slave’s I/O Units are not counted in the 32, but the I/O points must be counted in the total I/O points. Optical Fiber Cable (APF/PCF) C500 Slave Rack C500 CPU Rack C500 Master 3G2A5-RM001-(P)EV1 Optical I/O Units C500 Slave Repeater Unit 3G2A5-RT002-(P)EV1 3G5A2-RPT01-(P)E Optical I/O Units 32 Units (Not including the I/O Units on the Slave Rack.) 32 Units max. 15 Section C500 Systems 2-5 Example 4 I/O Link Units A maximum of 512 I/O points on I/O Units can be connected per Master, i.e., when the I/O Link Units are all set for 16 points each, up to 32 Units can be connected to one Master on a C500. This would mean, however, that all I/O points provided by the PC would be occupied and that no other I/O Units could be connected. (The C20 I/O Link Unit has no setting for the number of I/O points and is thus limited to 32 points.) C500 CPU Rack Optical Fiber Cable (APF/PCF) C500 CPU Rack Expansion I/O Rack C500 CPU Rack C20, K-type or P-type PC C20 I/O Link Unit 3G2C7-LK011-(P)E C500 Master 3G2A5-RM001-(P)EV1 I/O Link Unit 3G2A5-LK010-(P)E I/O Link Unit 3G2A5-LK010-(P)E Example 5 I/O Link Units, Slaves, and Optical I/O Units Up to two Slaves can be connected to one Master. Each I/O Link Unit requires 16 or 32 points (depending on the setting) and each Optical I/O Unit requires eight points. These may be used in any combination of I/O which does not exceed the total number of I/O points provided by the PC to which the Master is connected. If more than 32 Units are connected to the same Master, a Repeater Unit must be installed after the first 32 Units. The Slave’s I/O Units are not counted in the 32 Units, but the I/O points must be included in the total number of I/O points. Optical Fiber Cable (APF/PCF) C500 CPU Rack C500 Master 3G2A5-RM001-(P)EV1 Slave Rack C500 CPU Rack I/O Link Unit 3G2A5-LK010-(P)E C500 Slave 3G2A5-RT002-(P)EV1 32 Units (Not including the I/O Units on the Slave Rack.) 16 Optical I/O Units Repeater Unit 3G5A2-RPT01-(P)E 32 Units max. Section C1000H and C2000H Systems 2-6 2-6 C1000H and C2000H Systems Up to eight Masters can be connected to the same PC. The C1000H and C2000H provide 2,048 I/O points. This means that the total number of points used for I/O Units, I/O Link Units, and Optical I/O Units must be 2,048 or less. If, for example, 2,048 points are controlled by five or more Masters on a C1000H or C2000H, no more Masters or I/O points can be employed on that C1000H or C2000H. (The number of I/O points for the I/O Units on a C1000H’s CPU Rack or Expansion I/O Racks, however, must be keep to within 1,204.) The number of words in any one Remote I/O Subsystem must also be kept to within 32. For maximum cable lengths, refer to 5-2 Optical Fiber Cable. For limitations in Unit connections, refer to Maximum Number of Connectable Remote I/O Units under 2-1 Basic System. Example 1 Master and Slaves Up to two Slaves can be connected to one Master. Optical Fiber Cable (APF/PCF) C1000H or C2000H CPU Rack C500 Slave 3G2A5-RT002-(P)EV1 C500 Master 3G2A5-RM001-(P)EV1 C500 Slave Racks C500 Slave 3G2A5-RM001-(P)EV1 Example 2 Optical I/O Units C1000H or C2000H CPU Rack C500 Master 3G2A5-RT001-(P)EV1 Optical Fiber Cable (APF/PCF) Optical I/O Units 32 Units Repeater Unit 3G5A2-RPT01-(P)E Optical I/O Units 32 Units max. Up to 64 Optical I/O Units can be connected to one Master on a C1000H or C2000H. If more than 32 Units are connected to the same Master on a PC, a Repeater Unit must be installed after the first 32 Units. 17 Section C1000H and C2000H Systems 2-6 Example 3 Slaves and Optical I/O Units C1000H or C2000H CPU Rack C500 Master 3G2A5-RM001-(P)EV1 Optical Fiber Cable (APF/PCF) Optical I/O Units C500 Slave Rack C500 Slave 3G2A5-RT002-(P)EV1 Repeater Unit 3G5A2-RPT01-(P)E Optical I/O Units 32 Units 32 Units max. (Not including the I/O Units on the Slave Rack.) Up to 64 Units, consisting of Optical I/O Units and up to two Slaves, can be connected to one Master on a C1000H or C2000H. If more than 32 Units are connected to the same Master, a Repeater Unit must be installed after the first 32 Units. The Slave’s I/O Units are not counted in the 32, but the I/O points must be counted in the I/O point total. Example 4 I/O Link Units A maximum of 512 I/O points on I/O Link Units can be connected per master, i.e., when the I/O Link Units are all set for 16 points each, up to 32 Units can be connected to one Master on a C1000H or C2000H. (The C20 I/O Link Unit has no setting for the number of I/O points and is thus limited to 32 points.) C1000H or C2000H CPU Rack Optical Fiber Cable (APF/PCF) C20, K-type or P-type PC C1000H, or C2000H CPU Rack C500 Master 3G2A5-RM001-(P)EV1 18 C1000H or C2000H CPU Rack I/O Link Unit 3G2A5-LK010-(P)E C500, C1000H or C2000H Expansion I/O Rack I/O Link Unit 3G2A5-LK010-(P)E C20 I/O Link Unit 3G2C7-LK011-(P)E Section C200H System 2-7 Example 5 I/O Link Units, Slaves, and Optical I/O Units Optical Fiber Cable (APF/PCF) C1000H, or C2000H CPU Rack C500 Master 3G2A5-RM001-(P)EV1 C500 Slave Rack C1000H or C2000H CPU Rack I/O Link Unit 3G2A5-LK010-(P)E Slave 3G2A5-LK010-(P)E Optical I/O Units Repeater Unit 3G5A2-RPT01-(P)E 32 Units max. 32 Units (Not including the I/O Units on the Slave Rack.) Up to two Slaves can be connected to one Master. Each I/O Link Unit requires 16 or 32 points (depending on the setting) and each Optical I/O Unit requires eight points. These may be used in any combination desired that does not exceed the total number of I/O points provided by the CPU to which the Master is connected. If more than 32 Units are connected to the same Master, a Repeater Unit must be installed after the first 32 Units. The Slave’s I/O Units are not counted in the 32, but the I/O points must be counted in the I/O point total. 2-7 C200H System A maximum of two Masters, either optical or wired, may be connected in one C200H PC System. Masters may be mounted directly to the CPU Rack or to Expansion I/O Racks. Any slots may be used except for the two rightmost slots of the CPU Rack. Using the two rightmost slots will prevent mounting devices directly to the CPU. Regardless of the number of Masters, a maximum of five Slave Racks, either Optical or Wired, can be attached. Only I/O Units or Special I/O Units can be mounted to Slave Racks. A maximum of 64 Optical I/O Units can be connected, with a Repeater Unit installed after the first 32 Units. The number of words in any one Remote I/O Subsystem must be kept to within 32. There is a limit to the number of Special I/O Units which can be mounted to Slave Racks. The following table gives the maximum total of Units possible from groups A, B, C, or D when no Special I/O Units are mounted to any other Racks. These totals assume that only those Units in one of these groups are used. A High-speed Counter Units B C D Multipoint I/O Units Temperature Sensor Units NC211 Position Control Units 8 Units total 6 Units total 2 Units total Analog I/O Units NC111 and NC 112 Position Control Units ASCII Units 4 Units total 19 Section C200H System 2-7 When combining Units from more than one of these three groups, both of the following equations must be satisfied: 3A + B + 2C + 6D ≤ 12 A+B+C+D≤8 If the number of Special I/O Units controlled by the PC is ten, then no additional Special I/O Units may be mounted to any Rack. Example 1 Basic C200H System Optical Fiber cable (AGF/PF) C200H CPU Rack C200H Slave Rack C200H Slave C200H-RT001-P C200H-RT002-P C200H Master C200H-RM001-PV1 C200H Slave Rack C200H Slave C200H-RT001-P C200H-RT002-P C200H Slave Racks (5 max.) Optical I/O Units (64 max.) Example 2 Slaves Only One Master Optical Fiber Cable (APF/PCF) C200H CPU Rack C200H Master C200H-RM001-PV1 20 C200H Slave Rack C200H Slave Rack C200H Slave Rack C200H Slave Rack C200H Slave Rack C200H Slave C200H-RT001/002-P Section C200H System 2-7 Two Masters Optical Fiber cable (APF/PCF) C200H Master C200H-RM001-PV1 C200H Slave Rack C200H CPU Rack Expansion I/O Rack C200H Slave Rack C200H Slave Rack C200H Slave Rack C200H Slave Rack C200H Slave C200H-RT001/002-P C200H Master C200H-RM001-PV1 Example 3 Slaves with Expansion I/O Racks I/O Connecting Cable can be used to connect up to two Expansion I/O Racks to a Slave Rack. (The I/O Connecting Cable must be 2 m or less in length.) In any one C200H System, however, only a total of 5 Slaves and Slave-connected Expansion I/O Racks can be connected. One Master Optical Fiber Cable (APF/PCF) C200H Master C200H-RM001-P C200H Slave Rack C200H CPU Rack Expansion I/O Rack I/O Connecting Cable C200H Slave Rack I/O Connecting Cable Expansion I/O Rack C200H Slave Rack 21 Section Combined Systems 2-8 Two Masters C200H Masters C200H-RM001-PV1 Optical Fiber Cable (APF/PCF) C200H CPU Rack C200H Slave Rack Expansion I/O Rack I/O Connecting Cable I/O Connecting Cable C200H Slave Rack Expansion I/O Rack Expansion I/O Rack Example 4 I/O Link Units A maximum of 512 I/O points on I/O Link Units can be connected per master, i.e., when the I/O Link Units are all set for 16 points each, up to 32 Units can be connected to one Master on a C200H. (The C20 I/O Link Unit has no setting for the number of I/O points and is thus limited to 32 points.) C1000H or C2000H CPU Rack Optical Fiber Cable (APF/PCF) C200H CPU Rack C20, K-type or P-type PC C200H Master C200H-RM001-PV1 C500, C1000H or C2000H Expansion I/O Rack C20 I/O Link Unit 3G2C7-LK011-(P)E I/O Link Unit 3G2A5-LK010-(P)E 2-8 Combined Systems Example 1 Connecting Other Units to C200H Masters C500 Slaves 22 Up to two C500 Slaves, either optical or wired, can be connected to the C200H PC (regardless of the number of C200H Masters). C500 Slaves and C200H Slaves can also be used in combination; however, a maximum of five Slaves can be attached, with each C500 Slave counted as two Slaves. Any Wired Slaves must be counted in the total. Here, Special I/O Units can be mounted to C500 Section Combined Systems 2-8 Slave Racks as always, although a maximum of 20 words can be allocated on each C500 slave Rack. Words for Units on C500 Slave Racks are automatically allocated from the left as is normal in C500 Systems. Optical Fiber Cable (APF/PCF) C500 Slave Rack C200H CPU Rack C200H Master C200H-RM001-PV1 C500 Slave Rack C500 Slave 3G2A5-RT002-(P)EV1 Connecting through I/O Link Units C500 Slave 3G2A5-RT001/002(P)V1 The C200H PC can be connected to C120, C500, C1000H, and C2000H PCs through I/O Link Units. I/O Link Unit bits are allocated between IR 200 and IR 231. Words are allocated into this area according to I/O Link Unit settings for 1 word (16 points) or 2 (32 points). Optical Fiber Cable (APF/PCF) C200H CPU Rack C200H Slave Rack C200H Master C200H-RM001-PV1 C500, C1000H, or C2000H CPU Rack I/O Link Unit 3G2A5-LK010-(P)E Optical I/O Unit 32 words max. 23 Section Connection Precautions 2-9 Example 2 Connecting C200H Slaves to Other Masters C200H Slaves can be connected to C120 or C500 Masters. Connection conditions are the same as those for C500 Slaves, i.e., words for I/O Units on C200H Slaves are automatically allocated. Here, however, Special I/O Units cannot be mounted, and C200H I/O Units are handled as one word per Unit. Optical Fiber Cable (APF/PCF) C500 CPU Rack C200H Slave Rack C200H Slave Rack C500 Master 3G2A5-RM001-(P)EV1 C200H Slave C200H-RT001/002-P 64 Units max. 32 words max. Optical I/O Units Repeater Unit 3G2A5-RPT01-(P)E required for more than 32 Units. Note If a Unit with the blown-fuse detection function and alarm detection circuit (C200H-OD411/213/214/OA221) is used on a C200H Slave Rack that is connected to a PC other than a C200H/C200HS, all 16 I/O points will be regarded as outputs. Therefore, you will not be able to read the flags for blown-fuse detection function and alarm detection circuit from the ladder program. 2-9 Connection Precautions For limitations in Unit connections, refer to Maximum Number of Connectable Remote I/O Units under 2-1 Basic System. Slaves Install Slaves on the leftmost slot of the Rack in all but C200H Systems. In C200H Systems, Slaves contain the power supply and are mounted to the right of the Backplane, not to a slot. Slave Rack C500 Slave A Master cannot be mounted to a Slave Rack or to any Expansion I/O Rack connected to a Slave Rack. Slave Rack C500 Slave 24 Section Connection Precautions 2-9 A Slave Rack cannot be connected directly to a CPU Rack, i.e., it must be connected through the Slave to the Master. CPU Rack Slave Rack C500 Slave When connecting an Expansion I/O Rack in a C500, C1000H, C2000H, or C120 System, it must not be connected to a Slave Rack. Expansion I/O Racks may be connected to Slave Racks in C200H Systems. Link Adapters When the Units are connected in series, a disconnected line or a power failure in any one of them stops data transfer down the line past that point. This problem can be avoided by using Link Adapters. If a power failure occurs in a Unit connected to a branch line of a Link Adapter, the Unit is bypassed and signals continue to be transmitted to other Units down the line. For details on this and other uses of Link Adapters, refer to the Link Adapter Operation Manual. If a Remote I/O System is connected in series, the entire System will stop operating if any one link in the System is broken. To prevent this, Branching Link Adapters can be used with the Slave Racks, Optical I/O Units, and I/O Link Units in the System so that actual series connections go through the Link Adapters on a main line. In a branched System, the Master and the last Unit in the System are on the main line that runs through the Link Adapters; the rest of the Units in the System are on branch lines. Because connections do not run through any Unit linked in the System, the rest of the System will continue operating regardless of the status of any one Unit. Although beyond the scope of this Manual, there are measures that can be taken to shut down the PC System for failures in any one part of it even when Link Adapters are used. 25 Section Connection Precautions 2-9 A Remote I/O System connected through Link Adapters is shown below. Link Adapter Unit 3G2A9-AL002-(P)E Link Adapter Unit 3G2A9-AL002-(P)E C500 CPU Rack C120 CPU Rack C500 CPU Rack C500 Master 3G2A5-RM001-(P)EV1 C500 I/O Link Unit 3G2A5-LK010-(P)E C120 I/O Link Rack C120 I/O Link Unit 3G2A6-LK010-(P)E 26 C500 CPU Rack C500 I/O Link Unit 3G2A5-LK010-(P)E SECTION 3 Operations 3-1 3-2 3-3 3-4 Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O Link Unit Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unit Number and I/O Word Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O Word Allocation Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Section Block Diagrams 3-1 3-1 Block Diagrams The following block diagrams show the basic functional blocks for Units available in Optical Remote I/O Systems. C120 and C500 Master and Slave Master Fiberoptic/ electric converter Serial/ parallel converter I/O bus Data memory CPU System memory Counter SYSMAC C-series CPU Converting circuit Transmitting/Error Work memory I/O interface Test OK Terminator check Test switch Fiberoptic/ electric converter Serial/ parallel converter I/O bus CPU Transmitting/Error I/O interface Slave 28 Data memory SYSMAC C-series interface Work memory RUN output System memory I/O error RUN output SYSMAC C-series Backplane Section Block Diagrams 3-1 C200H Master and Slave Master Fiberoptic/ electric converter Serial/ parallel converter I/O bus CPU System memory C200H CPU C200H interface XMT/RCV Transmitting Work memory I/O interface Error End RS Unit No. (machine no.) Slave Fiberoptic/ electric converter Serial/ parallel converter CPU System memory Data memory I/O bus C200H interface RUN Work memory +24 V XMT/RCV I/O interface RUN output +5 V C200H Backplane POWER ERROR 1 ERROR 2 Unit no./ terminator Power supply RUN output Power source 100 to 120/200 to 240 VAC 29 Section Block Diagrams 3-1 I/O Link Unit I/O bus Fiberoptic/ electric converter Serial/ parallel converter System memory CPU Data memory I/O bus C-series interface Transmitting/ Error Work memory 16-pt input SW1 I/O interface 16-pt output SW2 RUN output 16-pt I/O 32-pt output Repeater output Used when Link Adapter is connected. Optical I/O Unit I/O bus Fiberoptic/ electric converter Serial/ parallel converter I/O bus Work memory CPU System memory Transmitting/ Error I/O interface Word setting Terminator setting RUN output AC power source Power supply +5 V +24 V Power source 30 C-series I/O bus Section I/O Link Unit Operation 3-2 3-2 I/O Link Unit Operation Of the three I/O Link Units, the C120 and C500 I/O Link Units can be set for operation via 16 input points, 16 outputs, 16 input and 16 output points, or 32 output points. The C20 I/O Link Units has no setting for the number of I/O points, and always operates via 16 input and 16 output points. (1) 16 Input Bits In the System shown below, CPU B sees 16 input bits. The I/O word allocations are determined by mounting location. CPU A sees 16 output bits. The word allocations are determined by the settings on the I/O Link Unit. The respective input and output words are treated as ordinary I/O words, nd data is transferred from CPU A to CPU B. “n” is the word set on the I/O Link Unit, i.e., that allocated it by the PC with the Master (CPU A). “m” is the word allocated to the I/O Link Unit by the PC to which it is mounted (CPU B). Master I/O Link Unit CPU A CPU B RM001 LK010 O (n) U T I N (m) Optical fiber cable LK010 setting Transmission bits: 16 input bits: IR m (2) 16 Output Bits As shown, the situation just explained is exactly reversed. I/O Link Unit Master CPU A CPU B RM001 LK010 (n) I N O U T (m) Optical fiber cable LK010 setting Transmission bits: 16 output bits, IR m (3) 16 Input and 16 Output Bits As shown, the two previously described situations are combined into one. I/O Link Unit Master CPU A CPU B (m) O LK010 I (n) U N T RM001 Optical fiber cable I (n+1) N O U T (m+1) LK010-E setting Transmission bits: 16 input bits and 16 output bits: IR m and IR m+1 31 Section Unit Number and I/O Word Allocation (4) 32 Output Bits 3-3 Again, the situation is the same as 16 output bits, except that four words are used instead of two. Master I/O Link Unit CPU A CPU B (m) I (n) N RM001 Optical fiber cable (n+1) I N LK010 O U T O U T (m+1) LK010-E setting Transmission bits: 32 output bits: IR m and IR m+1 3-3 Unit Number and I/O Word Allocation Allocation of I/O words for C20 I/O Link Units for C20, K-type PCs, and P-type PCs is covered in the Operation Manuals for these PCs and is not duplicated here. The remote I/O words allocated for the PC of the Master to which an C20 I/O Link Unit is connected are described below. Basic Allocation Word allocations on Racks in Remote I/O Systems follow basically the same pattern as the PC to which the Master is mounted, i.e., by the mounting order of and by the number of words required for each Unit mounted for C120, C500, C1000H, and C2000H Systems and by fixed slot words in C200H Systems. In either case, allocations start from the lowest word starting on the left side of the CPU Rack. When a Master is reached on a Rack, allocation jumps to the leftmost Unit mounted on the first Slave Rack connected to the Master, and then to the second Slave Rack, etc, until the terminator is reached. Then allocations return to the Unit following the Master and continue across the CPU Rack and Expansion I/O Racks until all the Units on all Racks have been allocated. Details on and examples of allocation are provided below. Words for Units not mounted to Racks (i.e., Optical I/O Units and I/O Link Units) are not determined as described, but according to switch settings on the Units, as described below. I I/O Link Units are allocated words both by the CPU to which they are directly connected and by the CPU to which they are connected via the Remote I/O System. When programming operations involving I/O Link Units, be sure you are using the words allocated by the CPU for which the program is being written. Terminator There must be one terminator set for each Master, and it must be the Unit at the opposite end of the I/O bus from the Master.The terminator may be a Slave, an I/O Link Unit, or an Optical I/O Unit. The Master checks for a terminator immediately upon power application. If the terminator is properly set, the other Units connected to the I/O bus are acknowledged. All following operation is based on this initial check. Therefore, if a Unit is not attached properly or if the power to a Unit is not on when this check is performed, that Unit will be ignored during actual operation. Slave Unit Number and Terminator Settings Because more than one Slave can be attached to each Master, unit number settings are necessary to distinguish the Slaves. unit numbers 0 through 7 can be set for C1000H, and C2000H Slaves; Unit numbers 0 through 4, for C200H Slaves; and unit numbers 0 and 1 for C120 and C500 Slaves. The same unit number cannot be used on more than one Slave under the same Master. Setting undefined unit numbers will prevent Slave operation. Set the Slave connected to 32 Section Unit Number and I/O Word Allocation 3-3 the Master as Unit #0, the Slave connected to Unit #0 as Unit #1, and so on. Setting unit numbers and a terminator is necessary for every Master, even when only one Slave is connected. Refer to 4-4 Switch Settings for details. Master Slave #0 Set to Unit #0 Slave #1 Set to Unit #1. Set as terminator. I/O Units can be mounted to any slot on Slave Racks, just as in any other Rack. Word numbers are assigned in the order the I/O Units are mounted. In C200H Systems, words are allocated according to Slave unit numbers as shown in the following table. Unit Number 0 1 2 3 4 Words 50 to 59 60 to 69 70 to 79 80 to 89 90 to 99 If an Expansion I/O Rack is connected to C200H Slave Racks with I/O Connecting Cable, the Expansion I/O Rack is automatically allocated the words for the next unit number. This number cannot be set for another Slave in the System. I/O Unit Words on C500 Slaves in C200H Systems I/O Units mounted on C500 Slave Racks connected to C200H Masters are allocated words as follows, according to the unit numbers of the C500 Slave . Unit Number 0 1 2 3 Words 50 to 69 60 to 79 70 to 89 80 to 99 Note that consecutive unit numbers cannot be assigned to C500 Slaves because of overlapping word allocations. I/O Units on C200H Slave Racks are automatically allocated words just like other I/O Units, except that Special I/O Units are allocated special bits. All I/O Units mounted on C500 Slave Racks also will be automatically allocated words as usual, except that only 20 words can be used. C200H Slaves Connected in Other PC Systems Connection conditions for C200H Slaves in other PC Systems (e.g., C500 or C1000H) are the same as those for C500 Slaves. DIP switch settings for these C200H Slaves must specify that they are not connected to C200H Masters. (See 4-4 Switch Settings.) Here, all I/O Units, including Special I/O Units, are automatically allocated words as usual, i.e., special bits are not allocated. 33 Unit Number and I/O Word Allocation Section 3-3 An Expansion I/O Rack cannot be connected to a C500 Slave Rack via I/O Connecting Cable. Unlike C200H Slaves, C500 Slaves do not have switches for setting output OFF/output hold during transmission error. All data is cleared from C500 Slaves during transmission errors. I/O Link Unit Word Settings I/O Link Unit word settings determine which I/O words will be occupied by the Unit. C120 and C500 I/O Link Units can be set to occupy 16 or 32 points. C20 I/O Link Units always occupy 32 points. On C-series PCs there are 16 bits to a word, so the I/O Link Unit will occupy either one or two words. Words 0 through 31 are available. The actual words allocated in C200H, C1000H, and C2000H Systems will vary from the switch settings as described below. When setting words, be sure not to set word numbers for one Unit which have already been set for another Unit. I/O Units mounted to Slave Racks are automatically assigned words according to their mounting location. Words for all I/O Link Units must be set using their DIP switches. For more details on settings, refer to 4-4 Switch Settings. I/O Link Unit Words in C200H Systems Although other PCs can be attached to the C200H through I/O Link Units, word allocations for these Units are the same as those for Optical I/O Units, i.e., words 200 through 231. The actual words allocated the I/O Link Units will be 200 greater than the values set on the Units’ switches. Optical I/O Unit Word Settings Use the DIP switches on Optical I/O Units to set their I/O words. Do not combine their input and output words into a single 16-point word. In other words, the two 8-point sections composing a single 16-point word must be either both input or both output in all but C200H Systems. The actual Optical I/O Unit words in C200H systems will be 200 greater than the values set on the Units’ switches. For more details on settings, refer to 4-4 Switch Settings. Word Multipliers of C1000H and C2000H The maximum number of bits a Master can transmit is 512 (32 words x 16 bits/ word). Words 0 to 31 can therefore be set for I/O Link Units and Optical I/O Units. However, since the C1000H, and C2000H PCs can handle up to 2,048 bits (128 words x 16 bits/word), the Units cannot be assigned to words 32 to 127 of these PCs without some identification other than the normal word settings. It is therefore necessary to assign numbers to the Masters to which I/O Link Units and Optical I/O Units are connected and identify the words with these numbers as well as the word settings. These additionally assigned numbers, which can be from 0 through 3, are called “word multipliers.” The following equation illustrates the relationship between word multipliers and word allocations. I/O word allocation = (32 words x word multiplier) + (word set on Unit) For example, suppose word 28 is set on an I/O Link Unit and word multiplier 2 is assigned to the Master of that I/O Link Unit. The I/O word of the I/O Link Unit, viewed from the PC, is computed as follows: 32 words x 2 + 28 words = word 92 A word multiplier does not have to be assigned to a Master to which only Slaves are connected because word numbers will be automatically assigned by “free location” to any I/O Units connected to the Slaves The I/O words assigned to Optical I/O Units, Slaves, or I/O Link Units connected to the Master with the lowest word multiplier must not be the same as the I/O words assigned to the last I/O Unit. The same word multiplier can be assigned to more than one Master. In this case, however, the same word must not be set on the Units on a Master having the same word multiplier as another Master. Setting Word Multipliers 34 Set the word multipliers in a C1000H or C2000H System using the Programming Console as shown below. Before setting word multipliers, set the mode selector Unit Number and I/O Word Allocation Section 3-3 switch to the PROGRAM position. Refer to your PC’s Operation Manual for details. Note If a Unit with the blown-fuse detection function and alarm detection circuit (C200H-OD411/213/214/OA221) is used on a C200H Slave Rack that is connected to a PC other than a C200H/C200HS, all 16 I/O points will be regarded as outputs. Therefore, you will not be able to read the flags for blown-fuse detection function and alarm detection circuit from the ladder program. Key sequence to generate the I/O table. CPU checks the I/O word assignment. Appears about two seconds after the automatic I/O word check. Indicates word multplier is not yet set. Word multiplier set upon pressing WRITE key; next master no. displayed. Repeatedly designate word multpliers. Appears for previously register word multpliers. Press write if nothing has to be changed. Displayed when all word multpliers. are set. 35 Section I/O Word Allocation Examples 3-4 Word multipliers must be assigned only to the Masters to which I/O Link Units or Optical I/O Units are connected. This message is not displayed for Masters to which only Slaves are connected. Asking for input of a word multplier Indicates the word multplier is not yet set. Mounting sequence of Master Master symbol I/O slot no. Mounting sequence 3-4 I/O Word Allocation Examples The following examples detail word allocations in the IR area. Example 1 C500 with Slaves With two Slaves connected to one Master, the Slaves are set to unit numbers 0 and 1. The order does not matter. The last Unit must be set as the terminator. If only one Slave is connected, set it as Unit number 0 and set it as the terminator. Slave #0 Masters CPU Rack Slave Rack 16 pts. 32 pts. IR 18 & 19 32 pts. IR 16 & 17 16 pts. IR 15 16 pts. IR 14 #0 Set to unit #0. IR 7 64 pts. IR 5 & 6 32 pts. IR 1, 2, 3, & 4 16 pts. IR 0 Slave #1 Expansion I/O Rack Slave Rack 32 pts. IR 24 & 25 16 pts. IR 23 16 pts. IR 28 16 pts. IR 22 32 pts. IR 26 & 27 16 pts. IR 21 16 pts. IR 20 #1 Set to unit #1. Set as terminator. Slave #0 Slave Rack 36 16 pts. IR 13 16 pts. IR 12 64 pts. IR 8, 9, 10, & 11 #0 Set to unit #0. Set as terminator. Section I/O Word Allocation Examples 3-4 Example 2 C500 with Optical I/O Units CPU Rack Master IR 30 “L” 16 pts. IR 7 32 pts. IR 5 & 6 64 pts. IR 1, 2, 3, & 4 16 pts. IR 0 IR 30 “L” IR 31 “L” IR 31 “L” Set as terminator. Optical I/O Units Set the word of each Unit by using the DIP switch. Because the I/O Units are assigned words starting at the lower end (word 00), duplication can be avoided by starting the Optical I/O Unit words in reverse order beginning with IR 31. IR 00 IR 01 IR 02 IR 03 IR 04 IR 31 PC I/O points Slave I/O points I/O Link Units and Optical I/O Units Be sure that words set for Optical I/O Units or I/O Link Units do not overlap with words being used for other I/O data. Do not combine input and output words into one 16-point word. Two 8-point words (i.e., Optical I/O Units) composing one 16-point word must both be either input or output. 37 Section I/O Word Allocation Examples 3-4 Example 3 C500 with Slaves and Optical I/O Units CPU Rack Slave #0 Master Slave Rack Set to unit #0. 16 pts. IR 7 32 pts. IR 12 & 13 32 pts. IR 5 & 6 32 pts. IR 10 & 11 64 pts. IR 1, 2, 3, & 4 16 pts. IR 9 16 pts. IR 0 16 pts. IR 8 #0 Set to unit #0 Slave #1 Slave Rack IR 30 “L” IR 30 “H” IR 31 “L” Optical I/O Units Set the word of each unit by using the DIP switch. IR 31 “H” 16 pts. IR 19 16 pts. IR 18 64 pts. IR 14 , 15, 16, & 17 #1 Set to unit #1. Set as terminator. Because the I/O Units are assigned words starting at the lower end (word 00), duplication can be avoided by starting the Optical I/O Unit words from the upper end. 38 Section I/O Word Allocation Examples 3-4 Example 4 C500 with Slaves, I/O Link Units, and Optical I/O Units CPU Rack CPU Rack Master C20, K-type or P-type PC I/O Link Unit (32 pts) : IR 28 & 29 16 pts. IR 8 16 pts. IR 7 32 pts. IR 5 & 6 64 pts. IR 1, 2, 3, & 4 16 pts. IR 0 I/O Link Unit (16 pts) : IR 30 Set to IR 28. Slave Rack Terminator IR 31 “H” IR 31 “L” Optical I/O Units 16 pts. IR 11 32 pts. IR 9 & 10 #0 Set to unit #0 Because the I/O Units are assigned words starting at the lower end (word 00), duplication can be avoided by starting the Optical I/O Unit words and I/O Link Unit words from the upper end. Do not use words being used for other I/O data. Do not combine input and output words into one 16-point word. Two 8-point words (i.e., Optical I/O Units) composing one 16-point word must both be either input or output. 39 Section I/O Word Allocation Examples 3-4 Example 5 C1000H or C2000H with Slaves, I/O Link Units, and Optical I/O Units C1000H or C2000H CPU Rack Optical I/O Units #0 Word Multiplier 0 Terminator Slave Rack 16 pts. IR 6 32 pts. IR 8 & 9 16 pts. IR 4 16 pts. IR 7 32 pts. IR 2 & 3 16 pts IR 6 16 pts. IR 1 16 pts. IR 0 Slave #0 Set words: IR 31 “H” IR 30 “L” Allocated words: IR 31 “H” IR 30 “L” C500 Expansion I/O Rack Slave Rack No Word Multiplier needed. (I/O Link and optical transmitting Units not connected.) #0 Slave Rack #1 16 pts. IR 19 16 pts. IR 15 16 pts. IR 18 16 pts. IR 14 16 pts. IR 17 32 pts. IR 12 & 13 16 pts. IR 16 16 pts. IR 11 16 pts. IR 10 Slave #0 16 pts. IR 22 16 pts. IR 21 16 pts. IR 20 Slave #1 C2000H CPU Rack C500 Expansion I/O Rack C20, K-type or P-type PC Word Multiplier 2 16 pts. IR 25 16 pts. IR 24 16 pts. IR 23 C20 I/O Link Unit (32 pts.) I/O Link Unit Set to 16 pts. Terminator Set words: IR 30 IR 29 Allocated words: IR 94 & 95 IR 93 C500 Expansion I/O Rack *C20 I/O Link Unit occupies 2 words. IR 31 can therefore not be set. Optical I/O Units Terminator Word Multiplier 1 16 pts. IR 28 16 pts. IR 27 16 pts. IR 26 Set words: IR 31 “H” IR 30 L” Allocated words: IR 63 “H” IR 62 “L” Check to see that same word in not allocated twice. Change word multiplier or word setting if necessary. Because the I/O Units are assigned words starting at the lower end (word 00), duplication can be avoided by starting the Optical I/O Unit words and I/O Link Unit words from the upper end. 40 Section I/O Word Allocation Examples 3-4 Do not use words being used for other I/O data. Do not combine input and output words into one 16-point word. Two 8-point words (i.e., Optical I/O Units) composing one 16-point word must both be either input or output. Example 6 C200H System with C200H Slaves Although up to five C200H Slaves can be attached, this example shows only four. Words 100 through 199 are allocated for Special I/O Units (High-speed Counter Units and Position Control Units) on the Slave Racks. Optical Fiber Cable (APF/PCF) C200H Master C200H CPU Rack C200H Slave Rack Set to unit number 0. Set to C200H Master. Slave #0 IR 4 IR 54 IR 3 IR 53 IR 2 IR 52 Master #0 IR 51 IR 0 IR 50 C200H Master C200H Expansion I/O Rack C200H Slave Rack Set to unit number 1. Set to C200H Master. Slave #1 IR 64 IR 14 IR 63 IR 13 IR 62 IR 12 IR 61 Master #1 IR 60 IR 10 C200H Slave Rack C200H Slave Rack Set to unit number 2. Set to C200H Master. Set as terminator. Cap unused connector. Slave #3 Slave #2 IR 84 IR 74 IR 83 IR 73 IR 82 IR 72 IR 81 IR 71 IR 80 IR 70 Set to unit number 3. Set to C200H Master. Set as terminator. Cap unused connector. Example 7 C200H System with C200H Slaves Connected to Expansion I/O Racks Although up to five C200H Slaves can be attached, this example shows only four, i.e., two actual Slaves and two Expansion I/O Racks connected to Slaves (which are also counted as Slaves). Words 100 through 199 are allocated for Special I/O Units (High-speed Counter Units and Position Control Units) on the 41 Section I/O Word Allocation Examples 3-4 Slave Racks. Expansion I/O Units are automatically allocated the words for the next unit numbers after the one set for the Slave to which they are attached. C200H Master C200H CPU Rack C200H Slave Rack Set to unit number 0. Set to C200H Master. Set as terminator. Cap unused connector. Slave #0 IR 4 IR 54 IR 3 IR 53 IR 2 IR 52 Master #0 IR 51 IR 0 I/O IR 50 C200H Master C200H Expansion I/O Rack C200H Expansion I/O Rack Automatically allocated words of unit number 1. IR 14 IR 13 IR 12 Master #1 IR 10 Slave #1 IR 64 IR 63 IR 62 IR 61 IR 60 C200H Expansion I/O Rack C200H Slave Rack Set to unit number 3. Set to C200H Master Set as terminator. Cap unused connector. 42 Automatically allocated words of unit number 2. Slave #3 Slave #2 IR 84 IR 74 IR 83 IR 73 IR 82 IR 72 IR 81 IR 71 IR 80 IR 70 Section I/O Word Allocation Examples Example 8 C200H System with C500 Slaves 3-4 This example shows the maximum number of C500 Slaves that can be used in a C200H System. C200H Master C200H CPU Rack C500 Slave Rack IR 4 IR 3 16 pts. IR 2 IR 55 No unit Master #0 or #1 32 pts. IR 54 & 53 IR 0 32 pts. IR 52 & 51 16 pts. IR 50 Slave #0 Set as Slave #0. C500 Slave Rack Set as Slave #2 Set as terminator. 64 pts. IR 75, 74, 73 & 72 16 pts. IR 71 16 pts. IR 70 Slave #0 43 Section I/O Word Allocation Examples Example 9 C200H System with Optical I/O Units C200H Master C200H CPU Rack IR 4 IR 3 Master #0 or #1 Set as terminator IR 1 IR 0 Set words 0 “L” 15 “H” Actual words 200 “L” 215 “H” Repeater Unit 3G5A2-RPT0 T-(P)E 32 units Repeater Unit between 32nd and 33rd units. 16 “L” 31 “H” 216 “L” 231 “H” 32 max. 64 Units max. Example 10 C200H System with I/O Link Unit Connection to Other PCs Optical Fiber Cable (APF/PCF) C200H Master C200H CPU Rack C500 CPU Rack IR 4 I/O Link Unit 16 points input 16 point output IR 3 Master #0 or #1 IR 1 Optical I/O Unit I/O Unit Optical I/O Units IR 0 44 Set word 0 “L” 1 3 “L” 3 “H” Actual word 200 “L” 201/202 203 “L” 203 “H” 3-4 Section I/O Word Allocation Examples 3-4 Example 11 C200H System with I/O Link Unit Connection to Other PC and Optical I/O Units C200H CPU Rack C200H Slave Rack C200H Slave Rack Set as Slave #0. Set for C200H Master. Set as Slave #4. Set for C200H Master. Slave #4 Slave #0 IR 4 IR 94 IR 3 IR 93 IR 53 IR 2 IR 92 IR 52 Master #1 IR 91 IR 51 Master #0 IR 90 IR 50 IR 54 C200H Slave Rack C200H Expansion I/O Rack Set as Slave #1. Set for C200H Master. Slave #1 IR 64 IR 14 IR 63 IR 13 IR 62 IR 12 IR 61 IR 11 IR 60 IR 10 C20, K-type or P-type PC C20 I/O Link Unit (32 points) Set word: C200H Expansion I/O Rack 0 Allocated words: Automatically allocated the words for Slave #2. 200 and 201 Slave #2 IR 74 IR 74 IR 72 Set as terminator. Cap unused connector. IR 71 IR 70 C200H Slave Rack Set word 3 “L” 2 “H” 2 “L” Actual word 203 “L” 202 “H” 202 “L” Set as Slave #3. Set for C200H Master. Set as terminator. Cap unused connector. Slave #3 IR 84 IR 83 IR 82 IR 81 IR 80 45 Section I/O Word Allocation Examples Example 12 C200H Slaves Connected to Other PCs 3-4 Masters other than the C200H do not have unit number settings. Words for all Slaves attached to them are allocated automatically in the order they are mounted. Optical Fiber Cable (APF/ PCF) C1000H CPU Rack C200H CPU Rack Set as Slave #0. Set for Master Other than C200H. Slave #0 16 pts. IR 20 IR 13 16 pts. IR 19 IR 12 Master IR 11 16 pts. IR 8 IR 10 16 pts. IR 7 IR 9 32 pts. IR 6 & 5 64 pts. IR 4, 3, 2, & 1 16 pts. IR 0 C200H CPU Rack Set as Slave #1. Set for Master other than C200H. Set as terminator. Cap unused connector. Slave #1 IR 18 IR 17 IR 16 IR 15 IR 14 Note If a Unit with the blown-fuse detection function and alarm detection circuit (C200H-OD411/213/214/OA221) is used on a C200H Slave Rack that is connected to a PC other than a C200H/C200HS, all 16 I/O points will be regarded as outputs. Therefore, you will not be able to read the flags for blown-fuse detection function and alarm detection circuit from the ladder program. 46 SECTION 4 Unit Components and Switch Settings 4-1 4-2 4-3 4-4 Remote I/O Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O Link Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optical I/O Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Section Remote I/O Units 4-1 4-1 Remote I/O Units C120, C500, C1000H, and C2000H Systems Masters Slaves Transmitting/Error indicator Test OK indicator Terminator Check indicator Test switch Optical connector Either APF or PCF can be connected to the optical connector on RM001-PEV1. Only PCF can be connected to RM001-EV1. Transmitting/Error indicator I/O Error indicator Unit no./Terminator selector (Remove the indicator cover to gain access.) Optical connector Only one connector is provided on 3G2A5-RT001-(P)E. Either APF or PCF can be connected to the optical connector on RT001-PE and RT002-PEV1. Only PCF can be connected to RT001-EV1 and RT002-EV1. RUN output terminals Indicators Unit Master/Slave Master Slave Indicator Transmitting Error Test OK Function Flashes during transmission. Lights during an error. When performing a transmission test: – Lights to indicate normal transmission. – Remains unlit to indicate an error. Testing is repeated as long as the switch is activated; the LED will go out at any point an error occurs. Terminator Check Lights to indicate activation and then goes out to indicate that the terminator has been located. I/O Error Lights to indicate an error in the I/O Bus at the Slave Unit or a mis-recognition at the PC. Switches and RUN Output Terminals Unit Master Indicator Test Switch Function Tests the transmission connections with the PC in PROGRAM mode. The testing is repeated as long as the switch is act vated. Slave Unit No./Terminator selector Pins 1 and 2 set the unit number. Pin 4 sets the terminator. Pin 3 is not used. RUN output RUN signal (Stays on during normal run or monitor time; goes off during programming or an error.) Model 3G2A6-RM001-(P)E for C120 48 The 3G2A6-RM001-(P)E Remote I/O Master Unit is not housed in a case. The housing for this Unit, called a “Remote I/O Rack,” must be specified separately when ordering. The name and function of each part of this C120 Master are the same as those of the C500 Master. Section Remote I/O Units 4-1 Remote I/O Rack Display Window Nameplate Case screw 3G2C4-SI027-E (100 VAC) Unit and Housing Assembly Case screw Display Window Nameplate Case screw Board guide C120 Master board Board guide Remote I/O Rack 49 Section Remote I/O Units 4-1 C200H Remote I/O Master Unit C200H-RM001-PV1 XMT/RCV indicator (transmitting, green) END RS indicator (terminator, red) ERROR indicator (red) Unit number selector Optical connector Indicators Unit XMT/RCV (Transmitting) Indicator Unit #0 or #1 Function Flashes if there is one or more Optical I/O Units or Slaves undergoing normal transmission. Not lit if all Optical I/O Units and Slaves have errors or if an error occurs in the CPU refresh cycle. Unit #2 or #3 Switches Not lit if even one of the Optical I/O Units or Slaves in the transmission has an error or if an error occurs in the CPU refresh cycle. Indicator ERROR (Transmission error) Function Lights if even one of the Optical I/O Units or Slaves in the transmission has an error or if an error occurs in the CPU refresh cycle. END RS (Terminator check) Not lit if all of the Optical I/O Units or Slaves in the transmission are normal. Is lit and remains so at the start of operation until a terminator has been located. Name Unit No. Function Used to set the unit number (machine number) of the Master (set to 1 or 3 for #1 or set to 0 or 2 for #2.) The system will not operate if two Masters are given the same unit number or if undefined values are set. Unit numbers are used for AR error flags (AR0014 and AR0015) and restart flags (AR0114 and AR0115). Either unit number can be set when only one Master is used. Note If numbers 0 or 1 are used to set the unit number (#0 and #1, respectively), transmission will continue even when transmission errors occur. If numbers 2 or 3 are used (#0 and #1, respectively), all transmissions to Slaves will be stopped for transmission errors. 50 Section Remote I/O Units 4-1 C200H Slave Unit (C200H-RT001-P Shown Here) RUN indicator (green) XMT/RCV indicator (transmitting, green) POWER (green) Fuses 250V 2 V MF51NR (5.2 dia. X 20) ERROR 1 indicator (red) ERROR 2 indicator (red) Power supply terminals Dip switch Optical connector cover Note The optical connector is accessed by removing the cover. (Use a screwdriver to open the cover if necessary.) Either APF or PCF cable can be connected. (Refer to 5-2 Optical Fiber Cable.) Always cap the unused connector if the Slave is the terminator. C200H Slave Indicators The operating conditions of C200 Slaves can be discerned from their indicators, as shown in the following table. XMT/RCV Not lit. ERROR 1 Not lit. ERROR 2 Not lit. RUN Not lit. Condition System not operating. Function Indicates that system check by Master is not finished or that power is not being supplied. Flashing. Not lit. ––– Not lit. Lit. Lit. Not lit. Not lit. Lit. --Not lit. Not lit. Normal trans. Trans. error I/O bus error Indicates normal transmission with Master. Indicates error in transmission with Master. Indicates error in I/O bus connected to I/O Unit on Slave. Flashing. Flashing. Lit. --- I/O verification error Indicates that configuration of I/O Units on Slave has changed. Flashing. Lit. Lit. Not lit. I/O setting error Indicate that Slave Input and Output Units have been reversed. Flashing. Lit. Flashing. --- I/O Rack not verified Indicates that an I/O Expansion Rack connected to the Slave via I/O Connecting Cable has not been verified by the PC’s CPU. Note “---” in the above table indicates that the stated condition can occur with the indicator either lit or not lit. See Section 7 Error Processing for corrective measures. 51 Section I/O Link Units C200H Slave Rack 4-2 The same Backplanes are used as for CPU Racks and Expansion I/O Racks. See Appendix A for details. Cap this connector. It is not used. I/O Connecting Cable connector Used to connect Expansion I/O Units. Cap when not used. I/O Units and/or Special I/O Units 4-2 Remote I/O Slave Unit C200H-RT001-P Slave mounting screws (M4) I/O Link Units C500 I/O Link Unit Rear View Transmitting/Error indicator Transmission points indicator Word/Terminator selector (Remove the indicator cover to gain access.) Optical connector Either APF or PCF can be connected to the optical connector on LK010-PE. Only PCF can be connected to LK010-E. Transmission points selector RUN output Repeating terminals Indicators Indicator Transmitting Error 16 IN 16 OUT Function Blinks during transmission Lights during an error Appropriate LED lights to indicate the setting of the Transmission Points selector on the back. 16 IN • 16 OUT 32 OUT Switches Terminals 52 Switch Word/Terminator selector Function Set the number of words of the I/O Link Unit and whether or not it is the terminator. Transmission Points selector Set the number of transmission points of the I/O Link Unit. Terminal RUN output Function RUN signal (Stays on during normal run or monitor time; goes off during programming or an error.) Power ON output Power ON signal (Stays on while the power of the I/O Link Unit to the PC is on). Section I/O Link Units C120 I/O Link Unit 4-2 The 3G2A6-LK010-(P)E I/O Link Unit is not housed in a case. The housing of this Unit, called an “I/O Link Rack,” must be specified separately when ordering. The name and function of each part of this C120 I/O Link Unit are the same as those of the C500 Link Unit. I/O Link Rack Display Window Nameplate Mounting screw 3G2C4-SI023-E (100 VAC) Unit and Housing Assembly Case mounting screw Display Window Nameplate Case mounting screw Board guide C120 I/O Link Unit board Board guide I/O Link rack 53 Section Optical I/O Units 4-3 C20 Link Unit RUN Output Stays ON during normal operating or monitoring; goes OFF during programming or errors. Repeater Output Terminal Sends repeater signals to a Link Adapter. The repeater output is ON when power is ON in the CPU and I/O Link Unit. Power Indicator Lit when power is being supplied to I/O Link Unit. Transmission/Error Indicator Flashes during normal transmission; lights for transmission or bus error. Optical Connectors Either APF or PCF can be connected to the LK011-P. Only PCF can be connected to the LK011 CPU/Expansion I/O Unit Connector Connect to C20, K-type, or P-type Connecting Cable (Cable varies with PC). AC power supply Grounds 4-3 Optical I/O Units Model number POWER TR/ERR indicator Word selector (Remove indicator cover to gain access.) I/O indicators Optical connector Either APF or PCF can be connected to the optical connectors on ‘‘–P” type units. Only PCF can be connected to other units. Terminator terminals RUN output I/O terminals Common terminal Power terminals Indicators 54 Indicator POWER TR/ERR 0 to 7 Function Lights when the power is on. Blinks during transmission. Lights during error. Indicate the ON/OFF status of I/O points. Section Switch Settings Switch Switch Word selector Terminals 4-4 4-4 Function Set to the Optical I/O Unit’s word. Terminal Function Terminator setting Short for terminator (the Unit at the end). I/O Terminals, common Terminals for I/O wiring (refer to each Unit’s specifications). Power input terminals Power supply terminals (refer to each Unit’s specifications). Switch Settings Switch Setting Order Set the Units using the following procedure: 1, 2, 3... 1. Turn off the power, set the unit numbers of the Slaves and check the last I/O word being used by the PC. For a C1000H or C2000H System, always set Slave unit numbers in order starting from number 0. 2. Set the Optical I/O Unit and the I/O Link Unit words so that no words are used twice. Also, do not set more than the available number of words. This will result in an I/O error. 3. Connect the optical fiber cables starting from the Master and working out to the terminator. It does not matter which connector is used for the line from the Master. 4. Set the terminator for the last Unit for each Master. Check to confirm that no intermediate Units have been accidentally set as terminators. 5. Apply power to the System in any convenient order. 6. After the terminator check indicator on the Master goes out, enter the I/O table through the Programming Console if required for your PC. If a terminator is not found, CPU WAIT’G will be displayed on the Programming Console. Once the I/O table has been entered, it is not necessary to re-enter it each time power is turned on, unless there is a change. 7. After entering the I/O table, specify word multipliers for Masters if you are using a C1000H or C2000H System. Note 1. Once the I/O table has been generated, it is retained in the memory even while power is turned off. 2. If the System does not operate properly after following the above steps, refer to Section 7 Error Processing. C120, C500, C1000H, and C2000H Slaves Be sure to set DIP switches with the power off. Remove the indicator panel, as shown, and set the switch according to the following chart. Although the 3G2A6-RT001-(P)V1 is a special terminator unit (i.e., it has only one connector), it must still be set as the terminator. Unit Number and Terminator Settings ON Dip switch 1 2 3 4 2120 22 Terminator Setting ON: Terminator Unit no. 55 Section Switch Settings Unit no. #0 #1 #2 #3 #4 #5 #6 #7 Pin 1 OFF OFF ON ON OFF OFF ON ON Pin 2 OFF ON OFF ON OFF ON OFF ON 4-4 Pin 3 OFF OFF OFF OFF ON ON ON ON C200H Master C200H-RM001-P Unit number selector The unit number is set to distinguish between Masters. The order of Master unit numbers is not important. Always turn off the power supply to the PC before setting, and use a screwdriver to set the number. Do not set the same unit number for more than one Master. Do not set values other than 0 through 3. C200H Slave C200H-RT001-P Dip switch 56 Section Switch Settings 4-4 Always turn off the power supply to the PC and to the Slave before setting. All DIP switch positions are OFF when the Unit is delivered. ON 1 2 3 4 5 6 7 8 Not used. (Leave OFF.) Data Clear/Retain for Transmission Errors OFF: Data cleared. ON: Data retained. Master Connected OFF: C200H ON: All others Terminator Setting OFF: Not terminator ON: Terminator Unit Number Setting Unit number #0 #1 #2 #3 #4 #5 #6 #7 Pin 1 OFF OFF OFF OFF ON ON ON ON Pin 2 OFF OFF ON ON OFF OFF ON ON Pin 3 OFF ON OFF ON OFF ON OFF ON Models C120, C500 C120, C500, C200H C120, C500, C200H, C1000H, C2000H Setting Example ON 1 2 3 4 5 6 7 8 Unit number: 3 Set as terminator. Master: C200H Data cleared for transmission errors. I/O Link Units Be sure to set DIP switches with the power off. Remove the indicator panel, as shown, and set the switches according to the following chart. Be sure to replace the cover when finished. The appearance of the switch is the same for all Link Units. The position of the switch for C500 I/O Links is shown below. It is located behind the indicator cover on the C120 I/O Link Unit too. On the C20 I/O Link Unit, the switch is located behind the cover on the side of the Unit. 57 Section Switch Settings 4-4 Word and Terminator Setting DIP Switch Settings Word Setting Terminator Setting ON 1 2 3 4 5 6 DIP switch 16 8 4 2 1 Word “H”/“L” ON : “H” The sum of the switches set to ON determines the word number. Set words in reverse order from word 31. In a C200H System, the actual word number will be 200 greater than the set value. Example: Setting IR 27 and terminator (Actually IR 227 in C200H System) ON 1 2 3 4 5 6 16 8 2 1 Set position 6 ON. Set pins 1, 2, 4, and 5 ON to set word 27 = (16 + 8 + 2 + 1). 58 Section Switch Settings Transmission Points Setting 4-4 Set the switch on the rear panel as shown in the following chart. This switch does not exist on the C20 I/O Link Unit. Switch Back Operation ON ON 1 2 3 4 1 2 3 4 16-point input 1 to 4: OFF DIP switch ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 16-point output 4: ON 1 to 3: OFF 16-point input 16-point output 2 & 3: ON 1 & 4: OFF 32-point output 2 to 4: ON 1: OFF Optical I/O Units Be sure to set DIP switches with the power off. Remove the indicator panel, as shown, and set the switch according to the following chart. Word and Terminator Setting DIP Switch Settings Word Setting Terminator Setting ON 1 2 3 4 5 6 DIP switch 16 8 4 2 1 Terminator setting ON: Terminator The sum of the switches set to ON determines the word number. Set words in reverse order from word 31. In a C200H System, the actual word number will be 200 greater than the set value. 59 Section Switch Settings 4-4 Example: Setting Word 29 “H” and terminator (Actually word 229 in C200H System) ON 1 2 3 4 5 6 16 8 4 1 Set position 6 ON. Set pins 1, 2, 3, and 5 ON to set word 29 = (16 + 8 + 4 + 1). Terminator Terminator Short-circuit terminals 0 and 1. 60 SECTION 5 System Installation 5-1 5-2 5-3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1-1 Masters and Slaves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1-2 I/O Link Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1-3 Optical I/O Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1-4 CPU, Slave, and Expansion I/O Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optical Fiber Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3-1 C200H Slave Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3-2 C20 I/O Link Unit Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Section Dimensions 5-1 Dimensions 5-1-1 Masters and Slaves C120 and C500 (Unit: mm) Master 34.5 170* 34.5 93 Slave 150* 93 250 250 *With optical fiber cable connected *With optical fiber cable connected Remote I/O Rack for C120 (Unit: mm) 350 340 120110 100 62 5-1 Section Dimensions 5-1 C200H Master (Unit: mm) 117 35 Rack 100.5 130 Approx. 140 Terminal Dimensions (Unit: mm) M3.5 3 Max. 7.3 C200H Slave Racks (Unit: mm) 8-slot Rack M4 screws 130 135 118 421 6.5 117 7.5 435 145* * Dimension with 16-point/12-point I/O Units 5-slot Rack M4 screws 130 135 118 6.5 316 330 7.5 117 145* * Dimension with 16-point/12-point I/O Units 63 Section Dimensions 3-slot Rack M4 screws 130 135 118 246 6.5 117 7.5 145* * Dimension with 16-point/12-point I/O Units 260 Mounting Dimensions (Unit: mm) L ± 0.2 130 M4 screws Backplane only 118 ± 0.2 A Backplane Backplane C200H-BC031 C200H-BC051 C200H-BC081 Type 3-slot 5-slot 8-slot L 246 316 421 A 260 330 435 5-1-2 I/O Link Units C500 I/O Link Unit (Unit: mm) 3G2A5-LK010-(P)E 34.5 150* 93 250 *With optical fiber cable connected 64 5-1 Section Dimensions 5-1 C120 I/O Link Rack (Unit: mm) 350 340 120110 100 C20 I/O Link Unit Two M4 holes Mounting Hole Dimensions 110 ± 0.2 I/O Link Unit 230 250 120 2-M4 65 Section Optical Fiber Cable 5-2 5-1-3 Optical I/O Units (Unit: mm) 170* 35 Two M4 holes 100 250 242 ± 0.5 *With optical fiber cable connected 5-1-4 CPU, Slave, and Expansion I/O Racks 250 150 A B 100 The figure above illustrates an 8-slot Rack. The 5-slot and 3-slot Racks are similar except that the length varies with the number of slots. Lengths, in millimeters, for all three models are given in the table below. Backplane 3G2A5-BC081 C500-BL061 3G2A5-BC051 C500-BL041 C500-BL031 5-2 Type 8-slot 6-slot 5-slot 4-slot 3-slot A 465 290 360 220 185 B 480 305 375 235 200 Optical Fiber Cable Plastic-clad Optical Fiber (PCF) and All-plastic Optical Fiber (APF) cable can be used for the communication lines of the Optical Remote I/O System. APF cable has the following features and functions. Use of APF cable is recommended if the transmission distance is 20 m or less. Quartz crystal cable can also be used by incorporating Link Adapters into the System to transmit up to 3 km. Refer to the Link Adapter Operation Manual for details. Features and Functions Low Cable Cost All-plastic optical fiber and optical connectors are less expensive than other optical fibers, reducing cable cost. 66 Section Optical Fiber Cable 5-2 Easy Processing and Installation Because the user can attach connectors to the plastic optical fiber cables, cables can be laid first and then the connectors can be attached, allowing optimum adjustment of cable length to eliminate wasted cable. This ease of handling also ensures quick recovery in the event of cable breakage. Transmission Distance Extendible to 200 m PCF cable can also be connected to APF Units to extend the transmission distance to up to 200 m. Cable Plastic optical fiber (APF) Plastic-clad optical fiber (PCF) For all-plastic optical fiber 20 m max. 200 m max. Unit For plastic-clad optical fiber Cannot be connected 800 m max. Note The above transmission distances can be extended by using a Link Adapter. For details, refer to the Link Adapter manual. Using APF Units The model names of APF Units are the same as those of corresponding PCF Units, except for the suffix “-P” added to APF Units. APF Units are identical to corresponding PCF Units in appearance, including the shape of the optical connectors. APF cable cannot be connected to PCF Units; PCF cable must be used to connect an APF Unit to a PCF Unit. Refer to Plastic Optical Fiber Cable Specifications for APF cable assembly and handling. A complete list of Optical Fiber Units is available in Appendix A Standard Models. Types of Cable The following three optical fiber cables can be used in an Optical Remote I/O System as listed below. Operating conditions are different for each of these cables. Fiber Application All-plastic (APF) For short-distance transmission and indoor use Plastic-clad (PCF) For medium-distance transmission Applicable Units Those with suffix “-P” All. Distance differs with Unit Transmission distance (max.) 20 m “-P” Units 200m Remarks Available from OMRON Non“-P” Units 800m Available from OMRON User must assemble connectors W/connectors Refer to cable specifications for handling instructions. Notes on Handling Optical Fiber Cable Be sure to attach the protective cap to the unused optical connector of the Unit specified as the terminator. This cap is supplied as an accessory to protect the module from external light interference. Although the optical fiber cable is designed to provide sufficient mechanical strength, never allow heavy objects to fall onto it. When installing the optical fiber cable with connectors, secure, on a stable block, the portion of the cable immediately before the connector so that the weight of the cable is not pulling on the connector. Always hold on to the connector when attaching or removing the cable; do not pull or push directly on the cable. The optical connector can be connected in one direction only. When connecting, be sure to insert the connector up to the locking position. Be careful not to soil the edges of the optical connectors. Attach the protective caps the connectors whenever the connectors are not in use. When the connec- 67 Section Wiring 5-3 tors have become dirty, lightly wipe them with clean tissue paper or cotton (moisten with ethyl alcohol if necessary to remove dirt). Do not, however, use any organic solvents other than ethyl alcohol. The minimum bending radius is 25 mm for APF cable; 15 mm for PCF cable. Never use the cable bent at a small radius. The total length of all cables in the system must not exceed 10 km. 3G5A2-PF002 All-Plastic Fiber Cable requires either Optical Connector A (when the cable length is 10 m or less) or Optical Connector B (when the cable length ranges from 8 to 20 m) per transmission line. These connectors are supplied in pairs. The optical connectors for APF Cable must be assembled by the user. Notes on Ordering and Assembling APF Cables 5-3 Wiring 5-3-1 C200H Slave Terminals C200H-RT001-P Fuse AC input Power supplied at either 100 to 120 VDC or 200 to 240 VDC Use enclosed device to short for 100 V Voltage switch power supply. When using 200 V power Shorted: 100 V supply verify that circuit is open. Open: 200 V LG Connect to independent ground to reduce noise interference and prevent shock. Connect to independent ground to prevent shock. Use to power DC Input Units. Use a sepa24-VDC output rate power supply if exceeding 3.0 A. If – 0.3 A 3.0 A is exceeded, PC may detect error and stop operation. GR + + RUN output ON in RUN mode. Use for accessing signals from PC in RUN mode. Note Be sure to use a wire of at least 1.25 mm2 in thickness. Use M3.5 screws for tightening crimp terminals. Use round crimp terminals for wiring. Do not connect bare stranded wires directly to terminal blocks. ! Caution Tighten the terminal block screws of the AC Power Supply to a torque of 0.8 NSm. Loose screws may result in burning or malfunction. Note Make sure that the 2-piece connector on the terminal block, shown below, clicks into place when attaching it, indicating that the lock lever is in place. Lock lever Lock lever 68 Section Wiring 5-3 C200H-RT002-P + Fuse 24 VDC Use a 24 VDC power supply. – NC NC Connect to independent ground to reduce noise interference and prevent shock. LG * GR NC Connect to independent ground to prevent shock. NC (There is no 24-VDC output.) RUN output ON in RUN mode. Use for accessing signals from PC in RUN mode. * The LG and GR terminals are connected internally. Note 1. Be sure to use a wire of at least 1.25 mm2 in thickness. Use M3.5 screws for tightening crimp terminals. Use crimp terminals for wiring. Do not connect bare stranded wires directly to terminal blocks. Tighten the terminal block screws to a torque of 0.8 NSm. 2. Make sure that the 2-piece connector on the terminal block, shown below, clicks into place when attaching it, indicating that the lock lever is in place. Lock lever Lock lever 69 Section Wiring 5-3-2 C20 I/O Link Unit Terminals RUN output Repeater output (Used only when connected to Link Adapter.) M4 screws 8.6 max. Link Adapter 8.6 max. Optical fiber connector M4 screws 70 Power supply (100 to 240 VAC) 5-3 SECTION 6 I/O Response Times 6-1 6-2 6-3 6-4 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C500 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C1000H and C2000H Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C200H Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Section C500 Systems 6-1 6-2 Introduction The time required to produce a programmed output to an input within a Remote I/O System varies with the scan time of the PC, the transmission time of the Remote I/O System, and the timing of the input. The processing that determines and the methods for calculating maximum and minimum response times from input to output are provided in this subsection. Calculations assume that both the input and the output are located on Slave Racks in a Remote I/O System. Although more precise equations are possible if required, equations used for the following calculations do not consider fractions of a scan. In looking at the following timing charts, it is important to remember the sequence in which processing occurs during the PC scan, particular that inputs will not produce programmed actions until the program has been executed. Input on Slave Rack Output on Slave Rack X When calculating the response times involving inputs and outputs from another CPU connected by an I/O Link Unit, the scan time of the controlling CPU and the scan time of the PC to which the I/O Link Unit is mounted must both be considered. ! Caution 6-2 Noise may increase I/O delays. C500 Systems With C500 Remote I/O Systems, both the scan time of the PC and the transmission time required by the Remote I/O System need to be considered in computing the I/O response times. Remote I/O Transmission Times The remote I/O transmission time is computed as follows: TRM = Total Slave transmission time for one Master = TRT = = ΣTRT + TTT Transmission time for each Slave 1.4 ms + (0.2 ms x n) Where n = number of I/O words on the Slave Rack TTT = Optical I/O Unit transmission time = 0.2 ms x m Where m = number of Optical I/O Units Minimum I/O Response Times The minimum response time occurs when all signals are processed as soon as they are received, meaning only one scan is required to execute the program before the output is made. Time = Input ON delay + scan time + TRM + output ON delay Maximum I/O Response Times The maximum response time occurs when the input just misses both the first remote I/O transmission and the program execution portion of the scan, meaning that processing must wait for the next transmission and then the next scan. Time = Input ON delay + scan time x 2 + TRM x 2 + TRT + output ON delay Example Computations 72 Calculations would be as shown below for input and output ON delays of 10 ms and a scan time of 20 ms. This example uses only one Slave Rack connected to Section C1000H and C2000H Systems 6-3 a Master and four words allocated on the Slave Rack. Because there is only one Slave, TRM and TRT are the same. TRT = 1.4 + (0.2 x 4) = 2.2 ms TRM = 2.2 ms Minimum I/O Response Time Time = 10 ms + 20 ms + 2.2 ms + 10 ms = 42.2 ms Maximum I/O Response Time Time = 10 ms + (20 ms x 2) + (2.2 ms x 2) + 2.2 ms + 10 ms = 66.6 ms Transmission Time for Remote I/O Errors 6-3 The above computations assume that there is no remote I/O error (including power interruptions). If an error occurs for a Slave, the response time would be increased by 20 ms for each Slave connected to the same Master as the Slave where the error occurred. If an error occurs for a Optical I/O Unit, the overall delay time would be increased by 5 ms for each Optical I/O Unit connected to the same Master as the Optical I/O Unit where the error occurred. C1000H and C2000H Systems With C1000H and C2000H Remote I/O Systems, both the scan time of the PC and the transmission time required by the Remote I/O System need to be considered in computing the I/O response times. Remote I/O Transmission Times The remote I/O transmission time is computed as follows: TRM = Total Slave transmission time for one Master = TRT = = ΣTRT + TTT Transmission time for each Slave 1.4 ms + (0.2 ms x n) Where n = number of I/O words on the Slave Rack TTT = Optical I/O Unit transmission time = 0.2 ms x m Where m = number of Optical I/O Units Minimum I/O Response Times The minimum response time occurs when all signals are processed as soon as they are received. Because remote I/O processing is handled in parallel with program execution, two scans are required so that the program is executed. Time = Input ON delay + scan time x 2 + TRM + output ON delay Maximum I/O Response Times The maximum response time occurs when the input just misses both the first remote I/O transmission and the program execution portion of the scan, meaning that processing must wait for the next transmission and then the next (i.e., the third) scan. Time = Input ON delay + scan time x 3 + TRM x 2 + TRT + output ON delay Example Computations Calculations would be as shown below for input and output ON delays of 10 ms and a scan time of 20 ms. This example uses a C1000H system with only one Slave Rack connected to a Master and four words allocated on the Slave Rack. Because there is only one Slave, TRM and TRT are the same. TRT = 1.4 + (0.2 x 4) = 2.2 ms TRM = 2.2 ms Minimum I/O Response Time Time = 10 ms + 20 ms x 2 + 2.2 ms + 10 ms = 62.2 ms 73 Section C200H Systems 6-4 Maximum I/O Response Time Time = 10 ms + (20 ms x 3) + (2.2 ms x 2) + 2.2 ms + 10 ms = 86.6 ms Transmission Time for Remote I/O Errors 6-4 The above computations assume that there is no remote I/O error (including power interruptions). If an error occurs for a Slave, the response time would be increased by 20 ms for each Slave connected to the same Master as the Slave where the error occurred. If an error occurs for a Optical I/O Unit, the overall delay time would be increased by 5 ms for each Optical I/O Unit connected to the same Master as the Optical I/O Unit where the error occurred. C200H Systems With C200H Remote I/O Systems, only the scan time of the PC needs to be considered in computing the I/O response times as long as the remote I/O transmission time is negligible and smaller than the scan time. The scan time, however, is increased by the presence of the Remote I/O System. Scan Time The scan time for Remote I/O Systems is increased by the following amount for each Master (approx.): 1.3 ms + 100 µs x (number of 8-pt. Units controlled through the Master + (number of 16-pt. Units controlled through Master x 2)) + α Where, α = 200 µs x number of words used by Special I/O Units A more detailed explanation of scan time operation and calculations is available in the PC Operation Manual. Minimum I/O Response Times The minimum response time occurs when all signals are processed as soon as they are received. Here, three scans are required so that the program is executed. Time = Input ON delay + scan time x 3 + output ON delay Maximum I/O Response Times The maximum response time occurs when the input just misses the program execution portion of the scan, meaning that processing must wait for the next transmission and then the next (i.e., the fourth) scan. Time = Input ON delay + scan time x 4 + output ON delay Example Computations 74 Calculations would be as shown below for input and output ON delays of 10 ms and a scan time of 20 ms. This example uses only one Slave Rack connected to a Master and four words allocated on the Slave Rack. Minimum I/O Response Time Time = 10 ms + 20 ms x 3 + 10 ms = 80 ms Maximum I/O Response Time Time = 10 ms + 20 ms x 4 + 10 ms = 100 ms SECTION 7 Error Processing 7-1 7-2 7-3 Self-diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1-1 C120, C500, C1000H, and C2000H Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1-2 C200H Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SR and AR Area Flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Locating Transfer Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Section Self-diagnosis 7-1 7-1 Self-diagnosis C-series Systems have self-diagnostic features to aid in the event of an error. These features are divided into hardware diagnosis and system diagnosis. In either case, the error message or FAL number is read through the Programming Console. Some errors are also monitored by SR bits and can be programmed for indication by an external alarm. The SR bits can also be programmed to stop PC operation in the event of specific errors. Refer to the Troubleshooting Charts on the following pages. 7-1-1 C120, C500, C1000H, and C2000H Systems The following tables are in pairs. The first one of each pair classifies the errors according to Programming Console displays and CPU LEDs. The second one of each pair provides details on possible causes and corrections according to Remote I/O Unit LEDs. Errors Before Operation Programming Console Display Error Error code SR bits CPU Waiting CPU LEDs Power: lit Waiting for remote power --For Transfer error in I/O bus. not lit Run: LEDs on Master 6112 ON (other than C1000H, C2000H) 25312 ON (C1000H, C2000H) Slave LEDs Optical I/O Unit LEDs I/O Link Unit LEDs Trans/ Error Test OK Terminator check Trans/ Error I/O error Power Trans/ Error Trans/ Error flash -- lit -- -- -- -- -- Cause Remote I/O Unit power OFF Correction Apply power to the Unit I/O bus line break lit -- -- -- -- -- -- -- No terminator lit -- -- -- lit -- -- -- Transfer error in I/O bus Check settings beginning with terminator and check word settings. flash -- -- not lit not lit lit not lit not lit Remote I/O bus error Check Remote I/O Units. not lit not lit not lit -- -- -- -- -- Remote I/O Unit error Replace Master. flash -- -- -- -- lit -- -- Slave unit number error Correct Slave unit number setting. Non-fatal Errors Programming Console Display Error Error code SR bits Remote I/O err Remote I/O errors B0 to B3 (other than C1000H, C2000H) B0 to B7 (C1000H, C2000H) For all Remote I/O errors 6112 ON (other than C1000H, C2000H) 25312 ON (C1000H, C2000H) CPU LEDs Power: lit Alarm: LEDs on Master lit Slave LEDs Optical I/O Unit LEDs I/O Link Unit LEDs Trans/ Error Test OK Terminator check Trans/ Error I/O error Power Trans/ Error Trans/ Error lit -- -- lit -- lit lit lit Cause Transfer error in I/O bus I/O bus line break lit 76 -- -- not lit not lit -- not lit not lit Remote power OFF or CPU error Correction Refer to 7-2 SR and AR Area Flags to locate the error. The System will automatically be restored upon correcting the error. Section Self-diagnosis LEDs on Master Slave LEDs Optical I/O Unit LEDs I/O Link Unit LEDs Cause Correction Trans/ Error Test OK Terminator check Trans/ Error I/O error Power Trans/ Error Trans/ Error lit -- -- -- lit -- -- -- Remote I/O bus error Check Slave Racks. not lit not lit not lit -- -- -- -- -- master error Replace Master. Programming Console Display Error Error code SR bits I/O VER ERR I/O verification error E7 For all I/O verification errors CPU LEDs Power: lit Alarm: LEDS on Master 7-1 6110 ON (other than C1000H, C2000H) 25310 ON (C1000H, C2000H) lit Slave LEDs Optical I/O Unit LEDs I/O Link Unit LEDs Trans/ Error Test OK Terminator check Trans/ Error I/O error Power Trans/ Error Trans/ Error -- -- -- -- -- -- -- -- Cause Correction Slave Rack Unit loose or an I/O Unit has been added. Non-remote I/O word and Optical I/O Unit word settings overlap. Verify I/O Table with the Programming Console and correct I/O settings. Cause Correction Fatal Errors Programming Console Display Error Error code SR bits CPU LEDs LEDs on Master I/O SET ERR I/O Setting error E0 None Power: lit Run: not lit Error: lit Slave LEDs Optical I/O Unit LEDs I/O Link Unit LEDs Trans/ Error Test OK Terminator check Trans/ Error I/O error Power Trans/ Error Trans/ Error -- -- -- -- lit -- -- -- Remote I/O Input and Output Units have been reversed. -- -- -- -- -- -- -- -- Optical I/O Unit input and output words combined. Verify I/O Table with the Programming g g Console and correct I/O Units U it or I/O Table. T bl Note If the same Unit number is assigned to more than one Slave or the same data word is set for I/O points of several Optical I/O Units, data contention occurs on the I/O bus, causing transmission errors. Transmission errors are also caused by external light interference if protective caps are not attached to unused connectors. 7-1-2 C200H Systems Lighting and flashing of the Master XMT/RCV LED depends on the unit number settings of the Master. For Masters #0 and #1, if any of the Masters involved in 77 Section Self-diagnosis 7-1 transmission has an error, the LED will flash. If all such Units have errors, the LED will go out. For Masters #2 and #3, all transmission will stop and the LED will go out if even one Unit has an error. I/O verification errors and I/O setting errors occur when an I/O table is used or when the power supply to a Slave is turned off and I/O Unit settings are changed during CPU operation. Condition Prior to system operation 78 Cause Correction --- CPU doesn’t detect the Master. Master not mount properly or CPU error. Check mounting of Master; turn power back ON. If error cannot be cleared, replace Master. --- --- Optical Remote I/O Unit power OFF or I/O bus line broken. Terminator not set. Turn on power to the Slaves and connected Units. Check optical fiber cables. Set the Unit farthest removed from Master as the terminator. lit lit not lit Slave I/O bus error. Replace faulty unit. --- --- --- not lit Transmission error Check optical fiber cables. in I/O bus. END RS XMT/ RCV Error 1 Error 2 RUN Master not detected not lit not lit not lit --- --- --- Remote I/O errors not lit not lit lit --- --- not lit lit lit --- not lit lit not lit not lit --- --- not lit Same word multiplier used for more than one Master. Check word multipliers and correct any that are redundant flash not lit not lit flash --- --- not lit Same unit number assigned more than once. Check AR02 through AR06 for the redundant unit numbers and correct them. flash not lit not lit not lit not lit not lit not lit Slave not verified. Check Slave unit numbers and turn power back ON. Then, turn CPU power supply back ON or restart Master. flash lit flash --- Expansion I/O Unit connected via I/O connecting cable not recognized by CPU. Check I/O Connecting Cable connections. Check I/O Expansion Rack words and the system configuration. If an I/O table is being used, reference it on the Programming Console, and restore the system configuration or recreate the I/O table. not lit not lit not lit not lit I/O bus line break or CPU error. Check optical fiber cable. If the cause is removed, recovery will be automatic. Otherwise replace unit. Transmission Error not lit lit not lit not lit I/O bus transmission line break or error. I/O bus error flash lit lit not lit Slave I/O bus error. Check all Slaves and Slave Racks. Replace faulty units. I/O verification error flash flash lit --- I/O Unit on Slave Rack removed or added. Reference the I/O table on the Programming Console, and reset I/O or recreate the I/O table. I/O setting error flash lit lit not lit Input and Output Units reversed on Slave Rack. Reference the I/O on the Programming Console, and restore the I/O Unit word allocations Transmission error not lit lit not lit not lit Transmission line shorted. Check optical fiber cables. Slave not confirmed Expansion I/O Rack not confirmed Remote I/O error (after starting system) C200H Slave LEDs Error Too many I/O points Remote I/O System operation failure C200H Master LEDs XMT/ RCV Remote I/O System operation failure flash/ lit lit not lit Section SR and AR Area Flags 7-2 7-2 SR and AR Area Flags The following tables show how to monitor errors using SR and/or AR bits. SR Bits in C120 or C500 Bit No. 15 14 13 12 11 10 9 8 7 6 5 4 3 Word 59 2 1 O O 0 Error Check bit Remote I/O Error flag Error Location Bits 8 to 15 Remote I/O Unit B0 to B3 Optical I/O Unit I/O Link Unit 00 to 31 00 to 31 Definition Bits 4 to 7 Indicates the Master by mounting location. B0 is the leftmost Master on the Rack. 8 Refers to the Optical I/O Unit word number. 0 Refers to the I/O Link Unit word number. 0, 1 0 1 1 Definition Indicates a failure in the Master. Indicates a failure in Slave #0. Indicates a failure in Slave #1. Indicates an even word. Indicates an odd word. Indicates a failure in the I/O Link Unit. The Error Check bit can be turned ON and OFF to read errors when they have occurred in more than one Unit. The Remote I/O Error flag indicates that an error has occurred in one of the Remote I/O Units. 79 Section SR and AR Area Flags 7-2 SR Bits in C1000H and C2000H Bit No. 15 14 13 12 11 10 9 8 7 6 5 4 3 Word 251 2 1 O O 0 Error Check bit Remote I/O Error flag Error Location Bits 8 to 15 Remote I/O Unit B0 to B7 Optical I/O Unit I/O Link Unit 00 to 31 00 to 31 Definition Bits 4 to 7 The codes (Remote Nos.) on the right are assigned to Masters on CPU or Expansion I/O Rack from the lowest word. 0 to 7 Indicates unit number of Slave with error. (#0 to #7) 8 Indicates a failure in Master. Indicates word allocated to Optical I/O Unit. 0, 2, 4, 6 Indicates “L” word. 0 2 4 6 Multiplier 0 Multiplier 1 Multiplier 2 Multiplier 3 1, 3, 5, 7 Indicates “H” word. 1 3 5 7 Multiplier 0 Multiplier 1 Multiplier 2 Multiplier 3 0, 1 2, 3 4, 5 6, 7 Multiplier 0 Multiplier 1 Multiplier 2 Multiplier 3 Indicates word allocated to I/O Link Unit. Definition The Error Check bit can be turned ON and OFF to read errors when they have occurred in more than one Unit. The Remote I/O Error flag indicates that an error has occurred in one of the Remote I/O Units. Note The number of the word to which an Optical I/O Unit or I/O Link Unit is actually assigned is calculated using the following formula. Word no. = (Word no. listed in the above table) + (Word multiplier listed in the above table x 32) SR and AR Bits in C200H C200H Error Numbers and Restart Flags 80 AR 0014 and AR 0015 AR 02 AR 03 through AR 06 Unit number of Master with error Unit number of Slave with error at beginning of operations Optical I/O Unit word numbers with errors at beginning of operations SR 251 Unit numbers and word numbers of all Remote I/O Units with errors after beginning of operations Bit No. AR 0014 AR 0015 AR 0114 AR 0115 Function ON for error in Master #1. ON for error in Master #0. Restart bit for Master #1. Restart bit for Master #0. Section SR and AR Area Flags 7-2 To restart after removing the cause of an error, turn the Restart bit ON and then OFF again. SR Word 251 Contents Bit No. 15 14 13 12 11 10 9 8 7 6 5 4 3 Word 251 2 1 O O 0 Error Check bit Remote I/O Error flag. Bits 4 to 7 Definition Error Location Bits 8 to 15 Remote I/O Unit B0 to B1 Indicates the unit number of the Master. 0 to 4 Indicates the Unit number of the Slave. Optical I/O Unit 00 to 31 Indicates word no. of Optical I/O Unit. 0 Indicates “L” word. 1 Indicates “H” word. 0, 1 Either indicate the I/O Link Unit. I/O Link Unit 00 to 31 Definition Indicates words no. set on I/O Link Unit. The Error Check bit can be turned ON and OFF to read errors when they have occurred in more than one Unit. The Remote I/O Error flag indicates that an error has occurred in one of the Remote I/O Units. Slaves numbered 0 through 4 are allocated 10 words each in order from 50 through 99, i.e., 50 through 59, 60 through 69, etc. Optical I/O Unit and I/O Link Unit word numbers are 200 greater than the number actually set. Unit Numbers and Word Numbers with Errors at Beginning of Operations Slaves The following Error flags go ON for duplication in Slave unit numbers or transmission errors at the beginning of operations. Flag AR 0200 AR 0201 AR 0202 AR 0203 AR 0204 Optical I/O Units Slave unit number 0 1 2 3 4 The following error flags for Optical I/O Units go ON for word duplication in words set for Optical I/O Units. 81 Section SR and AR Area Flags Word AR 03 AR 04 82 Bit AR 0300 Unit 0 “L” AR 0301 Word 7-2 Bit AR 0500 Unit 16 “L” 0 “H” AR 0501 16 “H” AR 0302 1 “L” AR 0502 17 “L” AR 0303 1 “H” AR 0503 17 “H” AR 0304 2 “L” AR 0504 18 “L” AR 0305 2 “H” AR 0505 18 “H” AR 0306 3 “L” AR 0506 19 “L” AR 0307 3 “H” AR 0507 19 “H” AR 0308 4 “L” AR 0508 20 “L” AR 0309 4 “H” AR 0509 20 “H” AR 0310 5 “L” AR 0510 21 “L” AR 0311 5 “H” AR 0511 21 “H” AR 0312 6 “L” AR 0512 22 “L” AR 0313 6 “H” AR 0513 22 “H” AR 0314 7 “L” AR 0514 23 “L” AR 0315 7 “H” AR 0515 23 “H” AR 0400 8 “L” AR 0600 24 “L” AR 0401 8 “H” AR 0601 24 “H” AR 0402 9 “L” AR 0602 25 “L” AR 0403 9 “H” AR 0603 25 “H” AR 0404 10 “L” AR 0604 26 “L” AR 0405 10 “H” AR 0605 26 “H” AR 0406 11 “L” AR 0606 27 “L” AR 0407 11 “H” AR 0607 27 “H” AR 0408 12 “L” AR 0608 28 “L” AR 0409 12 “H” AR 0609 28 “H” AR 0410 13 “L” AR 0610 29 “L” AR 0411 13 “H” AR 0611 29 “H” AR 0412 14 “L” AR 0612 30 “L” AR 0413 14 “H” AR 0613 30 “H” AR 0414 15 “L” AR 0614 31 “L” AR 0415 15 “H” AR 0615 31 “H” AR 05 AR 06 Section SR and AR Area Flags 7-2 Using Flags to Locate Errors C120, C500 CPU Rack 16 pts. 32 pts. Slave #0 Slave Rack IR 7 32 pts. IR 12 & 13 IR 10 & 11 IR 5 & 6 32 pts. 64 pts. IR 1, 2, 3, & 4 16 pts. IR 9 16 pts. IR 0 16 pts. IR 8 Slave Rack Slave #1 IR 30 “L” IR 30 “H” IR 31 “L” IR 31 “H” Optical I/O Units 16 pts. IR 19 16 pts. IR 18 64 pts.. IR 14, 15, 16, & 17 In the System depicted above, let’s assume an error has occurred in IR 31 “L” of the Optical I/O Unit. Word 59 shows the following data. Locating the Error Bit No. 15 14 Word 59 O O 3 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 1 O O O 1 O O O O 1 O O O 1 0 8 Monitoring word 59 with the Programming Console reveals the following data. Indicates a remote I/O error. Indicates transfer I/O word 031 “L”. 83 Section SR and AR Area Flags 7-2 To check for other errors, monitor 5900 and force-set the System. This causes the next error word to be displayed. Incremented one by the Error Check bit. Indicates transfer I/O word 31 “H”. To read the next error, reset the Error Check bit, then set it again. If the leftmost Master has an error, the following message is displayed. Errors in the Remote I/O Units cannot be read is there is an error in the Master. Master number This is an example program to stop PC operation if an error occurs in the Unit assigned to word 31 “L.” 5903 MOV(21) 59 Remote I/O Error flag turns ON when there is an error. The first step is thus to move IR 59 to DM 000. DM 000 5900 The next error is read and its word number displayed. If there is not another error, the data will be all 0s. ANDW(34) #FFF0 Bits 0 to 3 are masked. DM 000 DM 000 CMP(20) DM 000 #3100 Data in DM 000 (i.e., content of IR 59 with bits 0 to 3 masked) is compared with #3100. 6306 FALS(07) 01 END(01) 84 If data matches, there is an error in word 31 “L”, and the CPU stops. Section SR and AR Area Flags 7-2 C1000H, C2000H C1000H or C2000H CPU Rack Optical I/O Units Master 16 pts. IR 5 16 pts. IR 4 32 pts. IR 2 & 3 16 pts. IR 1 16 pts. IR 0 Slave Rack Slave #0 Multiplier #0 32 pts. IR 8 & 9 16 pts. IR 7 16 pts. IR 6 Set Word IR 31 “H” IR 30 “H” Allocated Word IR 31 “H” IR 30 “L” Expansion I/O Rack Optical I/O Units Master Multiplier #1 16 pts. IR 12 16 pts. IR 11 16 pts. IR 10 Set Word IR 31 “H” IR 30 “H” Allocated IR IR 63 “H” IR 62““L” In the System depicted above, let’s assume an error has occurred in IR 62 “L” of the Optical I/O Unit (IR 30 “L” of Master with a word multiplier of 1). IR 251 shows the following data. Locating the Error Bit No. 15 14 IR 251 O O 3 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 1 O O O 0 O O 1 O 1 O O O 0 2 8 Monitoring IR 251 with the Programming Console reveals the following data. Indicates a remote I/O error. Indicates transfer I/O word 030 “L” on rack #1 (Word 62 “L”). 85 Section SR and AR Area Flags 7-2 To check for other errors, monitor 25100 and force-set the System. This causes the next error IR to be displayed. Incremented one by the Error Check bit. Indicates transfer I/O IR 31 “H” of Master with a word multiplier of 1 (Wd 63 “H”). To read the next error, reset the Error Check bit and then set it. If the leftmost Master has an error, the following is displayed. Errors in the Remote I/O Units cannot be read if there is an error in the Master. Master number This is an example program to stop PC operation if an error occurs in the Unit assigned to IR 62 “L” (IR 30 “L” of Master with a word multiplier of 1). 25103 MOV(21) 251 Remote I/O Error flag turns ON when there is an error. The first step is thus to move IR 251 to DM 0000. DM 0000 25100 The next error is read and its IR number displayed. If there is not another error, the data will be all 0s. ANDW(34) #FFF0 Bits 0 to 3 are masked. DM 0000 DM 0000 CMP(20) DM 0000 # 3020 Data in DM 0000 (i.e., the content of IR 251 with bits 0 to 3 masked) is compared with #3020. 25506 FALS(07) 01 END(01) 86 If data matches, there is an error in IR 62 “L”, and the CPU stops. Section SR and AR Area Flags 7-2 C200H C200H CPU Rack C200H Slave Rack Slave #0 IR 7 IR 6 IR 54 IR 5 IR 53 IR 4 IR 52 Master #0 IR 51 IR 2 IR 50 Optical I/O Units Set Word 1 “H” 0 “L” IR 1 Allocated Word 201 “H” 200 “L” IR 0 C200H Slave Rack Expansion I/O Rack Slave #1 Optical I/O Units Master #1 IR 13 IR 64 IR 63 IR 12 IR 62 IR 11 IR 61 IR 10 IR 60 Set Word IR 31 “H” IR 30 “H” Allocated Word 231 “H” 230 “L” Locating the Error In the System depicted above, let’s assume an error has occurred in IR 230 “L” of the Optical I/O Unit. IR 251 shows the following data: Bit No. 15 14 IR 251 O O 3 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 1 O O O O O O 0 O 1 O O O 0 0 8 Monitoring IR 251 with the Programming Console reveals the following data. Indicates Remote I/O error. Indicates IR 30 “L” setting (Wd 230 “L” allocation). 87 Section SR and AR Area Flags 7-2 To check for other errors, monitor 25100 and force-set the System. This causes the next error word to be displayed. Incremented one by the Error Check bit. Indicates word 31 “H” setting (Wd 231 “H” allocation). To read the next error, reset the Error check bit and then set it. If the leftmost Master has an error, the following is displayed. Errors in the Remote Units cannot be read if there is an error in the Master. Indicates Remote I/O error. Indicates IR 30 “L” setting (Wd 230 “L” allocation). This is an example program to stop PC operation if an error occurs in the Unit assigned to IR 230 “L” (IR 30 “L” setting of 1). 25103 MOV(21) 251 Remote I/O Error flag turns ON when there is an error. The first step is thus to move IR 251 to DM 0000. DM 0000 25100 The next error is read and its IR number displayed. If there is not another error, the data will be all 0s. ANDW(34) #FFF0 Bits 0 to 3 are masked. DM 0000 DM 0000 CMP(20) DM 0000 # 3000 Data in DM 0000 (i.e., the content of IR 251 with bits 0 to 3 masked) is compared with #3000. 25506 FALS(07) 01 END(01) 88 If data matches, there is an error in IR 62 “L”, and the CPU stops. Section Locating Transfer Errors 7-3 7-3 Locating Transfer Errors Before Terminator Acknowledgment The Transmitting/Error indicator may indicate an error before the Terminator Check indicator goes off. If it does, the line may be disconnected or the power to one of the Units in the line may be off. To locate the problem, set the Unit just before the end as the terminator and test the System again. Continue moving the terminator up one Unit at a time until the Master is able to acknowledge a terminator. This will let you know what section of the line the problem is in. Check the power supply and data transfer line connections for that section and test the System again. The problem is here. Terminator check is successful with this Unit set as the terminator. Terminator check is not successful with this Unit set as the terminator. Original terminator Slave, I/O Link Unit, or Optical I/O Unit After Terminator Acknowledgment Check the Transmitting/Error indicator of each Unit in the line to determine where the error has occurred. The problem can then be corrected by repairing the transfer line between the last Unit with the Transmitting/Error indicator flashing, indicating normal transmission, and the first Unit with the Transmitting/Error indicator lit, indicating an error. The problem is here. Transmitting/Error indicator flashing Transmitting/Error Transmitting/Error indicator flashing indicator lit. Transmitting/Error indicator flashing Slave, I/O Link Unit, or Optical I/O Unit 89 Appendix A Standard Models Remote I/O Units, I/O Link Units, and Optical I/O Units are available as either APF or PCF units. The model names of APF Units are the same as those of corresponding PCF Units except for the suffix “-P” added to APF Units. APF Units are identical to corresponding PCF Units in appearance, including the shape of the optical connectors. These types differ from each in the optical fiber cable they can use and the transmission distances they allow. A complete description of these differences can be found in 5-2 Optical fiber Cable under the heading Transmission Distances. When connecting these two types of Units to each other, be sure to use plastic-clad optical fiber cable (PCF). Masters and Slaves Name Specifications For C500, C1000H, C2000H Master For C120 C120 Remote I/O Rack Slave APF/PCF PCF APF/PCF PCF APF/PCF For C200H For mounting Remote I/O 100 VAC Master For C500, w/1 optical connector (APF/PCF) C1000H, C2000H w/2 optical connectors (APF/PCF) w/1 optical connector (PCF) w/2 optical connector (PCF) For C200H Internal power supply 100 to 120 or APF/PCF 200 to 240 VAC 24 VDC C500 Slave Backplane For C500, C1000H, C2000H Slave Racks Model number 3G2A5-RM001-PEV1 3G2A5-RM001-EV1 3G2A6-RM001-PE 3G2A6-RM001-E C200H-RM001-PV1 3G2C4-SI027-E 3G2A5-RT001-PEV1 3G2A5-RT002-PEV1 3G2A5-RT001-EV1 3G2A5-RT002-EV1 C200H-RT001-P C200H-RT002-P C500-BL061 C500-BL041 C500-BL031 C200H Backplane C200H I/O Power Supply For CPU,, Expansion I/O,, or Slave Rack 10-slot 8-slot 5-slot 3-slot Voltage switchable between 100 to 120 and 200 to 240 VAC 24 VDC C200H-BC101-V2 C200H-BC081-V2 C200H-BC051-V2 C200H-BC031-V2 C200H-PS221 C200H-PS211 C200H I/O Connecting Cable Length: 30 cm Length: 70 cm Length: 2 m Length: 5 m Length: 10 m C200H-CN311 C200H-CN711 C200H-CN221 C200H-CN521 C200H-CN131 91 Appendix A Standard Models I/O Link Units Unit I/O Link Unit Specifications For C500, C1000H, C2000H PCs C120 I/O Link Rack C20 I/O Link Unit Connecting Cable For mounting I/O Link Unit For P-type and K-type PC For C20 APF/PCF PCF 100 VAC 70 cm 5 cm 32 cm 70 cm Model number 3G2A5-LK010-PE 3G2A5-LK010-E 3G2C4-SI023-E C20P-CN711 3G2C7-CN501 3G2C7-CN311 3G2C7-CN711 Optical I/O Units Unit Optical I/O U i Unit (APF/PCF) Optical I/O U i (PCF) Unit Specifications Model number No-voltage contact input AC/DC input AC input Relay contact output Transistor output Triac output No-voltage contact 10 mA 12 to 24 VAC/DC 10 mA 100 VAC 10 mA 250 VAC/24 VDC 2 A 12 to 48 VDC 0.3 A 100/200 VAC 1 A 8 pts. 8 pts. 8 pts. 8 pts. 8 pts. 8 pts. 100 VAC power supply l No-voltage contact input AC/DC input AC input No-voltage contact 10 mA 12 to 24 VAC/DC 10 mA 100 VAC 10 mA 200 VAC 10 mA 250 VAC/24 VDC 2 A 12 to 48 VDC 0.3 A 100/200 VAC 1 A 8 pts. 8 pts. 8 pts. 8 pts. 8 pts. 8 pts. 8 pts. 100 VAC l power supply Relay contact output Transistor output Triac output 3G5A2-ID001-PE 3G5A2-IM211-PE 3G5A2-IA121-PE 3G5A2-OC221-PE 3G5A2-OD411-PE 3G5A2-OA222-PE 100/200 VAC power supply l 100/200 VAC power supply 3G5A2-ID001-E 3G5A2-IM211-E 3G5A2-IA121-E 3G5A2-IA221-E 3G5A2-OC221-E 3G5A2-OD411-E 3G5A2-OA222-E 100/200 VAC l power supply Link Adapters and Repeater Units Name Link Adapter Repeater Unit Specifications Optical (APF/PCF), 3 connectors Optical (APF/PCF), RS-422, RS-232C 1 connector each RS-422, 3 connectors Optical (PCF), 3 connectors Optical (PCF), RS-422, RS-232C 1 connector each For more than 32 Remote I/O Slaves in an Optical Remote I/O System APF/PCF PCF Model number 3G2A9-AL002-PE 3G2A9-AL004-PE 3G2A9-AL001 3G2A9-AL002-E 3G2A9-AL004-E 3G5A2-RPT01-PE 3G5A2-RPT01-E All Plastic Optical Fiber Cable (APF) Name Plastic fiber optical cable Specifications Cable only (w/o optical connector). Order in units of 5 m for cables 5 to 100 m long. For longer cables, order in units of 200 or 500 m. Model number 3G5A2-PF002 Optical connector A With 2 optical connectors (brown) For plastic optical fiber cable 10 m long or shorter 3G5A2-CO001 Optical connector B With 2 optical connectors (black) For plastic optical fiber cable 8 to 20 m long 3G5A2-CO002 Plastic optical fiber set 1 m cable with optical connector A attached on both ends 3G5A2-PF101 92 Appendix A Standard Models Plastic-Clad Optical Fiber Cable (PCF) Name Cable for indoor use Cable for both indoor and outdoor use Specification Operating g temperature: –10° to 70°C 0.1 m w/connector 1 m w/connector 2 m w/connector 3 m w/connector 5 m w/connector 10 m w/connector 20 m w/connector 30 m w/connector 40 m w/connector 50 m w/connector 10 to 500 m, w/connector (specify cable length in units of 1 m when ordering) 510 to 800 m, w/connector (specify cable length in units of 1 m when ordering) Operating temperature: –10° to 70°C Model number 3G5A2-OF011 3G5A2-OF101 3G5A2-OF201 3G5A2-OF301 3G5A2-OF501 3G5A2-OF111 3G5A2-OF211 3G5A2-OF311 3G5A2-OF411 3G5A2-OF511 3G5A2-OF002 Operating temperature: 0° to 55°C (must not be exposed to sunlight) Note 1. Optical cable cannot be connected as easily as ordinary wire for breaks or extensions; carefully determine lengths when placing your order. 2. Fiber length L (m) Length L (m) 93 Appendix B Specifications Ratings Conforms to the SYSMAC C-series PCs. Common Characteristics Transmission Communication Transmission speed Transmission delay Time-sharing, multiplexing cyclic system Half-duplex 187.5 kbps 16 ms/128 bits. Transmission Distances Unit Plastic optical fiber (APF) Plastic-clad optical fiber (PCF) For all-plastic optical fiber 20 m max. 200 m max. For plastic-clad optical fiber Cannot be connected 800 m max. C120, C500, C1000H, and C2000H Remote I/O Master and Slave Units Item Transmission points RUN output Internal power supply Weight Master 512 pts. max. (including Special I/O Units) None Slave 512 max. (including Special I/O Units) Contact output (closed during operation) 5 VDC 750 mA max. 500 g max. Contact capacity: 2 A 250 VAC (cosine of phase angle = 1) 2 A 24 VDC 5 VDC, 550 mA max. 500 g max. C200H Remote I/O Master Units Transmission words Slave Racks: 50 words Internal power supply Weight Optical I/O Units and I/O Link Units: 32 words 5 VDC, 200 mA max. 350 g max. C200H Remote I/O Slave Units Slave Power supply C200H-RT001-P 100 to 120/200 to 240 VDC (switchable) 24 VDC 50/60 Hz C200H-RT002-P Allowable voltage variation 24-VDC output terminal Power consumption Weight RUN output 85 to 132/170 to 264 VDC 20.4 to 26.4 VDC 24 VDC +10%/–20%, 0.3 A max. (not applicable) 100 VA max. 80 W max. 1.3 kg max. 1.3 kg max Contact output: 1a contact Contact capacity: 250 VAC, 2 A (cosine of phase angle=1) 0.5A (cosine of phase angle=0.4) 24 VDC, 2 A Power output Transmission bits 5 VDC, 3 A (2.7 A actually supplied to I/O Units) 10 words per Slave 95 Appendix B Specifications C120 and C500 I/O Link Units Transmission bits External outputs 32 bits (max.) Switch-selectable settings 16 input 16 output 16 input, 16 output 32 output RUN output SPST-NO output (Model G6B) Contact capacity: 2 A (max.) Repeater output SPST-NO output (Model G6B), for repeater signal Internal power supply 5 V, 600 mA max Weight 500 g max. C20 I/O Link Units Transmission bits External outputs 32 bits 16 input, 16 output RUN output SPST-NO output (Model G6B) Contact capacity: 2 A (max.) Repeater output SPST-NO output (Model G6B), for repeater signal Supply voltage Operating voltage range Power consumption Insulation resistance 100 to 120/200 to 240 VAC 50/60 Hz 85 to 132/ 170 to 264 VAC 15 VA max. 10 MΩ min. (at 500 VDC) between AC terminals and housing Dielectric strength 2,000 VAC 50/60 Hz for 1 minute (between AC terminals and housing) Noise immunity 1,000 V p-p, pulse width: 100 ns to 1 µs, rise time: 1 ns Vibration 10 to 35 Hz, 2 mm double amplitude, in X, Y, and Z directions, 2 hours each Shock Ambient temperature Environment Humidity Grounding Structure Weight Dimensions 98 m/s2 in X, Y, and Z directions, 3 times each Operating: 0° to 55°C; Storage: –20° to 65°C No corrosive gas 35% to 85% (without condensation) Less than 100 Ω IEC IP-30 (mounted in a panel) 1 kg max. 120 (W) x 250 (H) x 43 (D) Optical I/O Units Transmission bits RUN output Power supply voltage Weight 96 8 bits (max.) Contact output,SPST-NO (Model G6B) (closed during operation) Contact capacity: 250 VAC 2 A (cosine of phase angle=1) (C200H: 0.5 A (cosine of phase angle = 0.4)) 24 VDC, 2 A Refer to each Unit’s specifications. Appendix B Specifications No-voltage Contact Optical Input Units Item Input voltage Input impedance Input current ON delay time OFF delay time No. of circuits ON voltage OFF voltage Power supply voltage Power consumption Weight 3G5A2-ID001-(P)E No-voltage contacts --- 10 mA typical. 10 ms max. 15 ms max. 8 pts. (per common) ----- 100 VAC 50/60 Hz 25 VA max. 580 g max. 1.1 kΩ 2.2k 3.9 kΩ IN 00 IN 01 IN 02 1.1 kΩ 2.2k 3.9 kΩ Internal Circuit IN 07 COM RUN output 0 Shorted: Terminator Open: Other units 1 2 RUN output 3 0 Terminator setting 1 Power indicator 2 AC input (100 VAC) Power circuit 3 4 1A 250 VAC 5 Word selector 6 4 5 6 7 8 9 10 7 11 COM 12 13 Transmitting/ Error indicator 14 Power source (100 VAC) Circuit Configuration Terminal Connections 97 Appendix B Specifications AC/DC Optical Input Units Item Input voltage Input impedance Input current ON delay time OFF delay time No. of circuits ON voltage OFF voltage Power supply voltage Power consumption Weight 3G5A2-IM211-(P)E 12 to 24 VAC/DC +10%/–15% 1.8 kΩ 10 mA typical (at 24 VDC) 10 ms max. 15 ms max. 8 pts. (per common) 10.2 VDC min. 3.0 VDC max. 100 VAC 50/60 Hz 20 VA max. 580 g max. 1.8kΩ IN 00 IN 01 IN 02 6.8kΩ 1.8kΩ IN 07 6.8kΩ Internal Circuit COM RUN output 0 Shorted: Terminator Open: Other units 1 2 RUN output 3 0 Terminator setting Power indicator Power circuit AC input (100 VAC) 1A 250 VAC 1 2 3 + 4 12 to 24 VAC 5 Word selector 6 7 COM 4 5 6 7 8 9 10 11 12 13 Transmitting/ Error indicator 14 Power source (100 VAC) Circuit Configuration 98 Terminal Connections Appendix B Specifications AC Optical Input Units Item Input voltage Input impedance Input current ON delay time OFF delay time No. of circuits ON voltage OFF voltage Power supply voltage Power consumption Weight 3G5A2-IA121-(P)E 100 VAC +10%/–15% 50/60 Hz 9.7 kΩ (50 Hz) 8 kΩ (60 Hz) 10 mA typical (at 100 VAC) 10 ms max. 15 ms max. 8 pts. (per common) 60 VAC min. 20 VAC max. 100 VAC 50/60 Hz 20 VA max. 580 g max. 330Ω 0.33 µF IN 00 330Ω IN 01 IN 02 6.8k 330Ω 0.33 µF IN 07 330Ω 6.8k Internal Circuit COM (100 VAC) RUN output 0 Shorted: Terminator Open: Other units 1 2 RUN output 3 0 Terminator setting Power indicator 1 2 Power circuit AC input (100 VAC) 3 4 1A 250 VAC 100 VAC 5 Word selector 6 7 COM 4 5 6 7 8 9 10 11 12 13 Transmitting/ Error indicator 14 Power source (100 VAC) Circuit Configuration Terminal Connections 99 Appendix B Specifications AC Optical Input Units Item Input voltage Input impedance Input current ON delay time OFF delay time No. of circuits ON voltage OFF voltage Power supply voltage Power consumption Weight 3G5A2-IA221-(P)E 200 VAC +10%/–15% 50/60 Hz 22 kΩ (50 Hz) 18 kΩ (60 Hz) 10 mA typical (at 100 VAC) 10 ms max. 15 ms max. 8 pts. (per common) 120 VAC min. 40 VAC max. 100 VAC 50/60 Hz 20 VA max. 600 g max. 910Ω 0.15 µF IN 00 1MΩ IN 01 IN 02 6.8k 910Ω 0.15 µF IN 07 1MΩ Internal Circuit 6.8k COM (200 VAC) 0 Shorted: Terminator Open: Other units 1 2 RUN output RUN output 3 0 Terminator setting Power indicator 1 2 AC input (100 VAC) Power circuit 1A 250 VAC 3 (200 VAC) 4 5 6 Word selector 4 5 6 7 8 9 10 7 11 COM 12 13 Transmitting/ Error indicator 14 Power source (100 VAC) Circuit Configuration 100 Terminal Connections Appendix B Specifications Contact Optical Output Units Item Max. switching capacity 3G5A2-OC221-(P)E Resistive: 2 A 250 VAC (cosine of phase angle = 1) 2 A 24 VDC Inductive: 0.5 A 250 VAC (cosine of phase angle = 0.4) 100 mA 5 VDC 15 ms max. 15 ms max. 8 pts. (per common) Electrical: 300,000 operations (resistive load) 100,000 operations (inductive load) Min. switching capacity ON delay time OFF delay time No. of circuits Service life Mechanical: 50,000,000 operations Power supply voltage Power consumption Weight 100/200 VAC 50/60 Hz 20 VA max. 600 g max. OUT 00 Internal Circuit OUT 01 OUT 02 OUT 07 Internal Circuit COM 0 Shorted: Terminator Open: Other units 1 2 RUN output RUN output L Terminator setting Power indicator L L AC input (100/200 VAC) Power circuit 1A 250 VAC 3 L 250 VAC + 24 VDC max L L Word selector L 0 1 2 3 4 5 6 7 L COM 4 5 6 7 8 9 10 11 12 13 Transmitting/ Error indicator 14 Power source (100/200 VAC) Circuit Configuration Terminal Connections 101 Appendix B Specifications Triac Optical Output Units Item Max. switching capacity Min. switching capacity Leakage current Saturation voltage ON delay time OFF delay time No. of circuits Fuse capacity Power supply voltage Power consumption Weight 3G5A2-OA222-(P)E 100/200 VAC +10%/–15%, 1 A 50/60 Hz 10 mA, 100 VAC 3 mA max. (at 100 VAC) 1.2 V max. 1 ms max. Max. 1/2 of load frequency 8 pts. (per common) 250 V, 5 A 100/200 VAC 50/60 Hz 20 VA max. 600 g max. OUT 00 22Ω 1.022 µF OUT 01 OUT 02 OUT 07 22Ω 1.022 µF Fuse Internal Circuit COM 0 Shorted: Terminator Open: Other units 1 2 RUN output RUN output 3 L Power indicator Terminator setting L L AC input (100/200 VAC) Power circuit 1A 250 VAC L L 100/200 VAC L Word selector L 0 1 2 3 4 5 6 7 L COM 4 5 6 7 8 9 10 11 12 13 Transmitting/ Error indicator 14 Power source (100/200 VAC) Circuit Configuration 102 Terminal Connections Appendix B Specifications Transistor Output Units Item Max. switching capacity Min. switching capacity Leakage current Saturation voltage ON delay time OFF delay time No. of circuits Fuse capacity Power supply voltage Power consumption Weight 3G5A2-OD411-(P)E 12 to 48 VDC +10%/–15%, 0.3 A --- 100 µA max. 1.5 V max. 0.2 ms max. 0.3 ms max. 8 pts. (per common) Fuse not provided. 100/200 VAC 50/60 Hz 20 VA max. 600 g max. OUT 00 OUT 01 OUT 02 OUT 07 Internal Circuit COM 0 Shorted: Terminator Open: Other units RUN output Power indicator 2 RUN output L L AC input (100/200 VAC) 1A 250 VAC 3 L Terminator setting Power circuit 1 L 12 to 48 VDC + L L Word selector L 0 1 2 3 4 5 6 4 5 6 7 8 9 10 7 11 L COM 12 13 Transmitting/Error indicator 14 Power source (100/200 VAC) Circuit Configuration Terminal Connections 103 Appendix C Power Supply Wiring Precautions Voltage Drop If the wiring distance for the power supply to a Slave Rack in a SYSMAC BUS Remote I/O System is too long, there will be a voltage drop that may result in the power supply becoming insufficient for the Slave Rack load. Design the system so that a stable power supply can be provided for all Slave Racks. Slave Rack Power Supply Cable conductor resistance and line current will cause voltage drops in the cables used for supplying power to Slave Racks. In the kind of system shown below, the current consumption for the Slave Rack load, as well as its internal current consumption, will add to the line current and further contribute to a voltage drop. Use cable sizes and wiring distances so that final voltages for all Slave Racks will stay within the allowable voltage variation ranges. 24-VDC power supply Internal current consumption Cable conductor Load current resistance consumption G730 Slave Rack Load Perform wiring so that a stable operating voltage that is sufficient for every load in the system can be provided. Resistance of Other Devices In systems where devices such as circuit protectors, contactors, connectors, and fuses are used between Racks, the internal and contact resistances of the devices will also contribute to voltage drop (in addition to the voltage drop caused by cable conductor resistance). Allow for these resistances when designing the system. Circuit protector, breaker, etc. 24-VDC power supply Cable conductor resistance Connector Contact resistance of relays or contactors Slave Rack Slave Rack Perform wiring so that a stable operating voltage that is sufficient for every load in the system can be provided. Note The conductor resistance and allowable current of cables will vary with their cross-sectional area, material, structure, and the ambient temperature. Select cables for the system after confirming the cable specifications in the relevant catalogs. 105 Appendix C Power Supply Wiring Precautions Power Supply Arrangement Supplying Power for I/O Altogether When designing systems where power is supplied for all I/O from the same power supply, it is necessary to consider the power consumption for each load and each Rack’s internal power consumption. Use cable sizes so that voltages for all loads and Racks in the system will stay within the allowable voltage variation ranges. 24-VDC power supply Cable conductor resistance G730 G730 G730 Perform wiring so that a stable operating voltage that is sufficient for every load in the system can be provided. Load Load Load Load Arranging I/O Power Supply When deciding whether to supply power for I/O from just one point or several points, observe the points below. Several Power Supplies When using more than one power supply, the power supplies can be placed at various points in the system (rather than grouping all the power supplies together) to reduce line current, and consequently, the voltage drop. One Power Supply When using only one power supply, observe the following points to limit voltage drop and thereby keep the voltage within the allowable range: • Use sufficiently thick cables. • Raise the output voltage of the power supply. • Make the wiring distances as short as possible. Power Failures It is necessary to decide how the system should operate in the event of a power failure. Choose one of the following: • A system where all operation is stopped if one power supply fails. • A system where operation can be continued in the event of a power failure in one power supply, by the provision of several power supplies at various points in the system. Cost When designing a system, also consider factors that will affect the overall cost, such as the number of power supplies, the thickness and length of cables, and wiring costs. 106 Appendix D Using the C200H-RM001-PV1 with CS1-series PCs Memory Allocation When using the C200H-RM001-PV1 Master Unit with a CS1-series PC, there are differences in memory allocation for the following areas (details given in Data Configuration below): • SYSMAC BUS Area • Optical I/O Unit and I/O Terminal Area. Data Configuration SYSMAC BUS Area (Slave Rack Allocation) The SYSMAC BUS Area contains 50 words with addresses ranging from CIO 3000 to CIO 3049. Each C200H Slave Rack is allocated 10 words based on the Rack’s rack number (No. 0 to 4). From these 10 words, one word (16 bits) is allocated to each slot in the Slave Rack from left (i.e., from the slot furthest away from the Slave) to right. Allocations are fixed by slot, i.e., if there is no Unit in a slot, the word normally allocated to that slot will not be used. Note 1. The words are allocated according to rack numbers even when two Master Units are being used. 2. If C500 Slaves (C500-RT201) are used, they are allocated twice the number of words allocated to C200H Slaves (20 words). Any two non-consecutive numbers between 0 and 3 can be set as rack numbers in this case. Allocated words Rack number 0 CS1 CIO 3000 to CIO 3009 C200H/HX/HG/HE/HS IR 050 to IR 059 1 CIO 3010 to CIO 3019 IR 060 to IR 069 2 CIO 3020 to CIO 3029 IR 070 to IR 079 3 CIO 3030 to CIO 3039 IR 080 to IR 089 4 CIO 3040 to CIO 3049 IR 090 to IR 099 Optical I/O Unit and I/O Terminal Area (Allocation for Slaves other than Slave Racks) The Optical I/O Unit and I/O Terminal Area contains 32 words with addresses ranging from CIO 3100 to CIO 3131. Each Slave is allocated 1 word based on its unit number setting (0 to 31) except for Optical I/O Units, which are allocated 2 words each. Note The words are allocated according to unit numbers even when two Master Units are being used. Allocated words Unit number 0 CIO 3100 CS1 C200H/HX/HG/HE/HS IR 200 1 CIO 3101 IR 201 to to to 31 CIO 3131 IR 231 Note When there are two Masters mounted to the CPU Rack, make settings so that the same words are not allocated to two different Slaves. 107 Appendix D Using the C200H-RM001-PV1 with CS1-series PCs Related Flags in Auxiliary Area (AR Area and SR Area) CS1 Description p Name SYSMAC BUS Error Flag (Non-fatal error) Address A40205 SYSMAC BUS Master Error Flags A40500 to A40501 Slave Number of A42504 to SYSMAC Bus Error A42506 After Startup A42504 only A42508 to A42515 SYSMAC BUS Slave Number Refresh Bit A50900 ON when an error occurs in a data transfer in the SYSMAC BUS system. The number of the Master involved is indicated with bits A40500 and A40501. When a transmission error occurs in the SYSMAC BUS system, the flag for the affected Master Unit will be turned ON. A40500: Flag for Master Unit #0 A40501: Flag for Master Unit #1 Corresponding p g flag g in C200H/HX/HG/HE/HS SR 25312 SR 25104 to SR 25115 When there is an error in a Slave Rack, these bits contain the Slave’s unit number. AR 0200 to AR 0204 (Slave Rack Error Flags) Each flag corresponds to a rack number (0 to 4) When there is an error in an Optical I/O Unit SR 25103 (Remote I/O Error Flag) (excluding Slave Racks), the status of A42504 The status of the flags in AR 03 to (0 or 1) indicates whether the unit is high or low. AR 06 indicate whether the unit is high or low. When there is an error in a Slave Rack, this byte AR 0015: Flag for Master Unit #0 contains the 2-digit hexadecimal unit number of AR 0014: Flag for Master Unit #1 the Master to which the Slave is connected. (0xB0 for Master Unit 0, 0xB1 for Master Unit 1) When there is an error in an Optical I/O Unit, this AR 03 to AR 06 byte contains the 2-digit hexadecimal unit Each flag corresponds to a unit number (00 to 1F, or 0 to 31 decimal). number and letter (L or H). Turn this bit ON to refresh the error information in A425 (unit number of Slave where error occurred after startup). SR 25100 CIO Area Allocation The CIO Area is not used. DM Area Allocation The DM Area is not used. Settings and Operation Initial Settings (Hardware Settings) • Mount a Master to a CS1 CPU Rack, a C200H Expansion I/O Rack, or a CS1 Expansion Rack. (Do not mount to a SYSMAC BUS Slave Rack.) In a basic system, up to two Masters can be mounted. There are no restrictions on the mounting position. • Using the unit number selector on the front side of the Master, set the Master unit number and specify whether to continue or stop operation in the event of a transmission error. • For each Slave Rack, set the rack number, set whether to clear or retain data during transmission errors, and set the type of Master connected. • Set the unit number for each Remote I/O Unit. • Wire the system using 2-core cable or optical fiber as required. • Set the terminators. • Connect the Programming Device to the PC. • Turn ON power for the Slave Racks and the Remote I/O Units. • Turn ON power for the PC. • Create I/O tables. 108 Using the C200H-RM001-PV1 with CS1-series PCs Appendix D Ladder Program No settings required. 109 Glossary Backplane A base to which Units are mounted to form a Rack. Backplanes provide a series of connectors for these Units along with wiring to connect them to the CPU. Backplanes also provide connectors used to connect them to other Backplanes. In some Systems, different Backplanes are used for different Racks; in other Systems, Racks differ only by the Units mounted to them. basic Link System A control system that includes only one of the following systems: Remote I/O System, PC Link System, Host Link System, or Net Link System. branch line A communications line leading from a Link Adapter to any but the terminators in a Link System. Branching Link Adapter A Link Adapter used to branch connections to Units in a Link System. Used either to prevent the entire System from shutting down for an interruption at only one point in the System or to enable connecting more than two Units in one System when each Unit supports only one connector. building-block PC A PC that is constructed from individual components, or “building blocks.” With building-block PCs, there is no one Unit that is independently identifiable as a PC. The PC is rather a functional assembly of components. combined Link System A control system that includes more than one of the following systems: Remote I/O System, PC Link System, Host Link System, or Net Link System. Control System All of the hardware and software components used to control other devices. A Control System includes the PC System, the PC programs, and all I/O devices that are used to control or obtain feedback from the controlled system. controlled system The devices that are being controlled by a PC System. Converting Link Adapter A Link Adapter used to convert between different types of optical fiber cable, different types of wire cable, or between optical fiber cable and wire cable. Such conversion is necessary to connect Units that use different forms of communication. CPU An acronym for central processing unit. In a PC System, the CPU executes the program, processes I/O signals, communicates with external devices, etc. CPU Backplane A Backplane used to create a CPU Rack. CPU Rack Part of a building-block PC, the CPU Rack contains the CPU, a Power Supply, and other Units. With most PCs, the CPU Rack is the only Rack that provides linkable slots. data area An area in the PC’s memory that is designed to hold a specific type of data, e.g., the LR area is designed for to hold common data in a PC Link System. distributed control A automation concept in which control of each portion of an automated system is located near the devices actually being control, i.e., control is decentralized and ‘distributed’ over the system. Distributed control is a concept basic to PC Systems. electrical noise Electrical ‘static’ that can disturb electronic communications. The ‘snow’ that can appear on a TV screen is an example of the effects of electrical noise. 111 Glossary Expansion I/O Backplane A Backplane used to create an Expansion I/O Rack. Expansion I/O Rack Part of a building-block PC, an Expansion I/O Rack is connected to either a CPU Rack or Slave Rack to increase the number of slots available for mounting Units. I/O Block Either an Input Block or an Output Block. It provides mounting positions for replaceable relays. I/O capacity The number of inputs and outputs that a PC is able to handle. This number ranges from around one-hundred for smaller PCs to two-thousand for the largest ones. I/O Control Unit A Unit mounted to the CPU Rack in certain PCs to monitor and control I/O points on Expansion I/O Units. I/O devices The devices to which terminals on I/O Units, Special I/O Units, or Intelligent I/O Units are connected. I/O devices may be either part of the Control System, if they function to help control other devices, or they may be part of the controlled system. I/O Interface Unit A Unit mounted to an Expansion I/O Rack in certain PCs to interface the Expansion I/O Rack to the CPU Rack. I/O Link Created in an Optical Remote I/O System to enable input/output of one or two IR words directly between PCs. The words are input/output between the PC controlling the Master and a PC connected to the Remote I/O System through an I/O Link Unit or an I/O Link Rack. I/O Link Rack A Rack used with certain PCs (e.g., C120) to mount an I/O Link Unit. I/O Link Unit A Unit used with certain PCs to create an I/O Link in an Optical Remote I/O System. I/O point The place at which an input signal enters the PC System or an output signal leaves the PC System. In physical terms, an I/O point corresponds to terminals or connector pins on a Unit; in terms of programming, an I/O point corresponds to an I/O bit in the IR area. I/O Terminal A Remote I/O Unit connected in a Wired Remote I/O Subsystem to provide up to sixteen I/O points at one location. I/O Terminals provide fixed transistor inputs or outputs. I/O Unit The most basic type of Unit mounted to a backplane to create a Rack. I/O Units include Input Units and Output Units, each of which is available in a range of specifications. I/O Units do not include Special I/O Units, Link Units, etc. Input Block A Unit used in combination with a Modular Remote Terminal. An Input Block provides mounting positions for replaceable relays. Each relay can be selected according to specific input requirements. Input Remote Terminal A Remote Terminal that provides input points. Link Adapter A Unit used to connect communications lines, either to branch the lines or to convert between different types of cable. There are two types of Link Adapter: Branching Link Adapters and Converting Link Adapters. link A hardware or software connection formed between two Units. “Link” can refer either to a part of the physical connection between two Units (e.g., optical links in 112 Glossary Wired Remote I/O Systems) or a software connection created to data existing at another location (Network Data Links). linkable slot A slot on either a CPU or Expansion I/O Backplane to which a Link Unit can be mounted. Backplanes differ in the slots to which Link Units can be mounted. Link System A system that includes one or more of the following systems: Remote I/O System, PC Link System, Host Link System, or Net Link System. Link Unit Any of the Units used to connect a PC to a Link System. These are Remote I/O Units, I/O Link Units, PC Link Units, Host Link Units, and Net Link Units. main line In a Link System connected through Branching Link Adapters, the communications cable that runs from the Unit at each end of the System through the Link Adapters. Master Short for Remote I/O Master Unit. noise interference Disturbances in signals caused by electrical noise. Optical Slave Rack A Slave Rack connected through an Optical Remote I/O Slave Unit. Optical I/O Unit A Unit that is connected in an Optical Remote I/O System to provide 8 I/O points. Optical I/O Units are not mounted to a Rack. optical cable link In a Wired Remote I/O System, an optical cable connecting two Converting Link Adapters. Specified because the System otherwise uses wire communications. optical communications A communications method in which signals are sent over optical fiber cable to prevent noise interference and increase transmission distance. optical fiber cable Cable made from light conducting filaments used to transmit signals. Output Block A Unit used in combination with a Modular Remote Terminal. An Output Block provides mounting positions for replaceable relays. Each relay can be selected according to specific output requirements. Output Remote Terminal A Remote Terminal that provides output points. PC An acronym for Programmable Controller. PC System With building-block PCs, all of the Racks and independent Units connected directly to them up to, but not including the I/O devices. The limits of the PC System on the upper end is the PC and the program in its CPU and on the lower end, I/O Units, Special I/O Units, Optical I/O Units, Remote Terminals, etc. peripheral device Devices connected to a PC System to aid in system operation. Peripheral devices include printers, programming devices, external storage media, etc. printed circuit board A board onto which electrical circuits are printed for mounting into a computer or electrical device. Programmable Controller A computerized device that can accept inputs from external devices and generate outputs to external devices according to a program held in memory. Programmable Controllers are used to automate control of external devices. Although single-unit Programmable Controllers are available, building-block Programmable Controllers are constructed from separate components. Such Pro- 113 Glossary grammable Controllers are formed only when enough of these separate components are assembled to form a functional assembly, i.e., there is no one individual Unit called a PC. programming device A peripheral device used to input a program into a PC or to alter or monitor a program already held in the PC. There are dedicated programming devices, such as Programming Consoles, and there are non-dedicated devices, such as a host computer. Rack An assembly of various Units on a Backplane that forms a functional unit in a building-block PC System. Racks include CPU Racks, Expansion I/O Racks, I/O Racks, and Slave Racks. relay-based control The forerunner of PCs. In relay-based control, groups of relays are wired to each other to form control circuits. In a PC, these are replaced by programmable circuits. Remote I/O Master Unit The Unit in a Remote I/O System through which signals are sent to all other Remote I/O Units. The Remote I/O Master Unit is mounted either to a CPU Rack or an Expansion I/O Rack connected to the CPU Rack. Remote I/O Master Unit is generally abbreviated to simply “Master.” Remote I/O Slave Unit A Unit mounted to a Backplane to form a Slave Rack. Remote I/O Slave Unit is generally abbreviated to simply “Slave.” Remote I/O Subsystem A Master and all of the Remote I/O Units connected in series to it. A Remote I/O Subsystem exists when more than one Master is mounted to a PC. If Subsystems exist, the System is considered a Multilevel Remote I/O System. Remote I/O System A system in which remote I/O points are controlled through a Master mounted to a CPU Rack or an Expansion I/O Rack connected to the CPU Rack. Remote I/O Unit Any of the Units in a Remote I/O System. Remote I/O Units include Masters, Slaves, Optical I/O Units, I/O Link Units, and Remote Terminals. Remote Terminal A Remote I/O Unit connected in a Wired Remote I/O Subsystem to provide up to sixteen I/O points at one location. Remote Terminals feature replaceable relays that can be individually changed to meet specific I/O requirements. series A wiring method in which Units are wired consecutively in a string. In Link Systems wired through Link Adapters, the Units are still functionally wired in series, even though Units are placed on branch lines. Slave Short for Remote I/O Slave Unit. Slave Rack A Rack containing a Remote I/O Slave Unit and controlled through a Remote I/O Master Unit. Slave Racks are generally located away from the CPU Rack. slot A position on a Rack (Backplane) to which a Unit can be mounted. Special I/O Unit A dedicated Unit that is designed for a specific purpose. Special I/O Units include Position Control Units, High-speed Counter Units, Analog I/O Units, etc. switching capacity The voltage/current that a relay can switch on and off. system configuration The arrangement in which Units in a System are connected. transmission distance The distance that a signal can be transmitted. 114 Glossary Unit In OMRON PC terminology, the word Unit is capitalized to indicate any product sold for a PC System. Though most of the names of these products end with the word Unit, not all do, e.g., a Remote Terminal is referred to in a collective sense as a Unit. Context generally makes any limitations of this word clear. unit number A number assigned to some Link Units and Special I/O Units to assign words and sometimes other operating parameters to it. wire communications A communications method in which signals are sent over wire cable. Although noise resistance and transmission distance can sometimes be a problem with wire communications, they are still the cheapest and the most common, and perfectly adequate for many applications. Wired Slave Rack A Slave Rack connected through a Wired Remote I/O Slave Unit. work word A word that can be used for data calculation or other manipulation in programming, e.g., LR words not used in a PC Link or Net Link System. 115 Index A E Abbreviations, model numbers, error processing, applications, precautions, errors AR area flags, Error Check bit, , , error numbers and restart flags (C200H), locating in C1000H, or C2000H Systems, in C120 or C500 Systems, in C200H Systems, transfer errors, monitoring using SR and AR bits in C200H, , using SR bits in C1000H, and C2000H, using SR bits in C120 or C500, Remote I/O Error flag, , , SR area flags, word duplication flags, B block diagrams I/O Link Units, Optical I/O Units, Remote I/O Master Units, Remote I/O Master Units (C200H), Remote I/O Slave Units, Remote I/O Slave Units (C200H), C C1000H, and C2000H Systems configuration, response time, Example, C200H Basic System Configuration, I C120 Systems, configuration, I/O Link Rack, dimensions, C20 Systems, configuration, I/O Link Racks, for C120, unit and housing assembly, C200H Remote I/O Slave Racks, C200H Systems configuration, I/O Link Unit words in, response time, word allocation in, C500 Systems configuration, response time, cable optical fiber, transmission distance, types of optical fiber, CPU WAIT’G, D delay time, in C500 Remote I/O Systems, , dimensions C500 CPU Racks, Expansion I/O Racks, , I/O Link Units, Optical I/O Units, Remote I/O Master Units, Remote I/O Master Units (C200H), Remote I/O Racks, Remote I/O Slave Units, Slave Racks, C200H, I/O Link Unit definition, dimensions, power supply terminals (C20), I/O Link Units block diagram, channel settings, dimensions, indicators, nomenclature, operation, , switch settings for, switches, terminals, transmission points setting for, word allocation, words in C200H Systems, I/O points, maximum per System, I/O word allocation for C1000H, and C2000H Systems, for C200H Slaves connected to other PCs, for C200H System with C200H Slaves, for C200H System with C200H Slaves and Expansion I/O Racks, for C200H System with C500 Slaves, for C200H System with I/O Link Unit Connection to other PC, for C200H System with Optical Transmitting I/O Units, for C500 Master with Optical Transmitting I/O Units, 117 Index for C500 Master with Slaves, for C500 Master, Slaves, I/O Link Units, I/O Units, for C500 Master, Slaves, Optical I/O Units, for complex C200H System configuration, for Optical I/O Units, setting order, P power supply, terminals C20 I/O Link Unit, C200H Slaves, indicators I/O Link Units, Optical I/O Units, , Remote I/O Master Units, Remote I/O Master Units (C200H), Remote I/O Slave Units, Remote I/O Slave Units (C200H), precautions, applications, general, operating environment, safety, installation, precautions, Programming Console displays, CPU WAIT’G, entering I/O table through, L programming, simplification by Remote I/O System, protection, against complete system failure, Link Adapter, branching, Link Adapters, , N noise interference, reduction by Remote I/O System, nomenclature, Optical I/O Units, O operating environment, precautions, optical fiber cable, handling of, ordering and assembling APF cable, transmission distance, types and functions of, Optical I/O Units assigning word numbers for, block diagram, dimensions, error flags for word duplication, indicators, maximum number of for C200H, nomenclature, switch setting for, switches, terminals, terminator settings for, unit components, word settings for, Optical Remote I/O System advantages, branchline, mainline, overview, using Link Adaptors, Optical Remote I/O Systems, definitions of types, 118 R rack numbers, , Remote I/O Master Units block diagram, , dimensions, , indicators, , switch settings (C200H), switches, switches and RUN output terminals, unit components, , Unit numbers (C200H), Remote I/O Racks, dimensions, unit and housing assembly, Remote I/O Slave Units allocating word numbers for, block diagram, , C200H Slaves in other PC Systems, dimensions, indicators, , mounting to rack, switch settings, , switch settings (C200H), switches and RUN output terminals, terminals (C200H), unit components, , Unit numbers, Remote I/O Subsystem, Remote I/O System Multilevel System, overview, response time C1000H, and C2000H Systems, C200H Systems, C500 Systems, Index S safety precautions. See precautions self–diagnosis, Slave Racks, C200H, Special I/O Units and word allocation in C200H Systems, in C200H Systems, specifications, switch settings I/O Link Units, Optical I/O Units, Remote I/O Master Units (C200H), Remote I/O Slave Units, Remote I/O Slave Units (C200H), switches I/O Link Units, Optical I/O Units, Remote I/O Master Units, Remote I/O Master Units (C200H), Remote I/O Slave Units, system configuration basic, C1000H, and C2000H Systems, I/O Link Units, Slaves, Optical I/O Units, Link Units, Master and Slaves, Optical I/O Units, Slaves and Optical I/O Units, C120 Systems, I/O Link Units, I/O Link Units, Slaves, Optical I/O Units, Masters and Slaves, Optical I/O Units, Slaves and Optical I/O Units, C20 Systems, C200H Systems, basic configuration, C200H Slaves and different type Masters, connecting to other PCs, I/O Link Units, one Master and several Slaves, Slaves with Expansion I/O Racks, , two Masters and several Slaves, C500 Systems, I/O Link Units, I/O Link Units, Slaves Optical I/O Units, Master and Slaves, Optical I/O Units, Slaves and Optical I/O Units, Unit connection, system design, T terminals I/O Link Units, Optical I/O Units, terminators, , , , I/O Link Units, Optical I/O Units, Remote I/O Slave Units, settings, troubleshooting, charts C200H Systems, most PC Systems, U unit components I/O Link Units, Optical I/O Units, Remote I/O Master Units, Remote I/O Master Units (C200H), Remote I/O Slave Units, Remote I/O Slave Units (C200H), Unit numbers, , W word allocation for Remote I/O Slave Units, in C200H Systems, 119 Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual. Cat. No. W136-E1-3 Revision code The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version. Revision code 2 3 Date August 1989 December 1999 Revised content Complete reorganization and rewrite. C200H Slave Backplanes added. Name of Optical Transmitting I/O Units changed to Optical I/O Units. I/O response times added. C20 I/O Link Unit added. Precautions, Appendix C, and Appendix D added. Page 9: Slaves per Master for C1000H/C2000H corrected to 8 from 2 for the top table. Page 24: Note added after second diagram on page. Page 35: Note added after Setting Word Multipliers. Page 47: Note added after diagram. Page 73: Information on wiring and installation added after diagram. Page 74: Note added to diagram. Information on wiring added after diagram. Page 101: Changes made to model numbers for C200H Master and C200H Backplanes. Page 102: Some information on I/O Link Units, Optical I/O Units, and Link Adapters removed. Page 103: Information on Quartz Cable removed. Page 107: “10G” changed to “98 m/s2” in table. Page 105: “For plastic-clad optical fiber” column has been deleted from the Transmission Distances table. 121 ">
Download
Advertisement
Key features
Flexibility and customization
Rapid data transmission
Long transmission distances
Noise immunity
Easy design and adjustment
Short downtime in case of failure
Distributed control
Frequently asked questions
An Optical Remote I/O System is a type of distributed control system that uses optical fiber cables to transmit data between a Programmable Controller (PC) and remote I/O devices. This allows for long distances, high speed communication, and noise resistance.
Optical Remote I/O Systems include units like Masters, Slaves, I/O Link Units, and Optical I/O Units. Masters control the system, Slaves expand I/O points, I/O Link Units connect to other PCs, and Optical I/O Units handle specific I/O functions. Each unit has its own specific role and function.
Optical Remote I/O Systems offer several benefits, including flexibility in configuration, fast communication speeds, long transmission distances, and resistance to electromagnetic noise. This makes them suitable for a wide range of industrial applications.