- Home
- Domestic appliances
- Climate control
- Space heaters
- Empire Heating Systems
- HearthRite Infrared Heater (HR06, 10) Natural
- Owner's manual
Empire HR06, 10 HearthRite Infrared Heater Owner's Operation And Installation Manual
Add to my manuals
24 Pages
advertisement
▼
Scroll to page 2
of 24
INFRARED VENT-FREE NATURAL GAS SPACE HEATER OWNER ’S OPERATION AND INSTALLATION MANUAL HR06MN-1 HR10MN-1 HR10TN-1 Do not store, or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or gas supplier. Table of Contents Important Safety Information.................................2 Product Features.....................................................3 Proper Ventilation & Fresh Air..............................4 Installation................................................................6 Operating Your Heater............................................10 Cleaning & Maintenance.......................................13 Trouble Shooting...................................................14 Specifications..........................................................17 Parts List..................................................................19 Warranty Information...........................................24 WARNING: If the information in this manual is not followed exactly, a f i r e o r e x p l o s i o n m a y r e s u l t causing property damage, personal injury, or loss of life. WARNING: This is an unvented gasfired heater. It uses air (oxygen) f r o m t h e r o o m i n w h i c h i t i s installed. Provisions for adequate combustion and ventilation air must b e p r o v i d e d . R e f e r t o A i r F o r Combustion and Ventilation section on page 4 of this manual. A Division of Empire Comfort Systems,Inc. 918 Freeburg Avenue Belleville,IL 62220 Phone : 618-233-7420 or 1-800-851-3153 Fax : 618-233-7097 or 1-800-443-8648 www.hearthrite.com WA R N I N G : I m p r o p e r installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or gas supplier. This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion.An unvented room heater productes approximately one (1) ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of gas input per hour. Refer to page 3. *Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. Installer: Please leave these instructions with the consumer. Consumer: Please retain these instructions for future use. IMPORTANT SAFETY INFORMATION WARNINGS I M P O R TA N T: R e a d t h i s owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. WARNING: Do not use any accessory not approved for use with this heater. WARNING: Any change to this heater or its controls can be dangerous. Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater. 1. 2. 3. 4. Due to high temperatures, heater should be kept out of traffic and away from furniture and draperies. Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut down. Allow surface to cool before touching. Carefully supervise young children when they are in the same room with heater. Make place sure grill guard is in before running heater. Always run heater with control knob at ON, LOW or HIGH locked positions. Never set control knob between locked positions. Poor combustion This appliance is only for use and higher levels of carbon with the type of gas indicated monoxide may result. on the rating plate. This 10. Do not use heater if any part appliance is not convertible for has been under water. use with other gases. Immediately call a qualified If you smell gas service technician to inspect Shut off gas supply. the room heater and to Do not try to light any appliance. replace any part of the control Do not touch any electrical switch, system and any gas control do not use any phone in your which has been under water building. 11. Turn off heater and let cool Immediately call your gas supbefore servicing. Only a qualified plier from a neighbor’s phone. service person should service Follow the gas supplier’s and repair heater. instructions. 12. Operating heater above If you cannot reach your gas elevations of 4,500 feet could supplier, call the fire cause pilot outage. department. Do not install models HR10MN DANGER: Carbon monoxide and HR10TN in a bathroom. poisoning may lead to death! This heater needs fresh, Carbon Monoxide Poisoning. outside air ventilation to run Early signs of carbon monoxide properly. This heater has an poisoning resemble the flu with Oxygen Depletion Sensor headaches, dizziness, or nausea (ODS) safety shutoff system. If you have these signs, the heater The ODS shuts down the may not be working properly. Get heater if not enough fresh air fresh air at once! Have heater is available. See Fresh Air For serviced. Some people are more Combustion And Ventilation affected by carbon monoxide than pages 4 through 6 others. These include pregnant Keep all air openings in the women, persons with heart or lung front and bottom of heater disease or anemia, those under the clear and free of debris. This influence of alcohol, and those will insure enough air for at high altitudes. proper combustion Natural Gas: Natural gas is If heater shuts off. Do not odorless. An odor-making agent is relight until you provide fresh, added to natural gas. The odor outside air. If heater keeps helps you detect a natural gas leak . shutting off, have it serviced. However, the odor added to natural Do not operate heater gas can fade. natural gas may be where flammable liquids or present even though no odor exists. vapors are used or stored Make certain you read and underunder dusty conditions stand all warnings. Keep Turn heater off before using this manual for reference. It is your furniture polish, wax, carpet guide to safe and proper operation cleaner, or similar products. If of this heater. heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. 5. 6. 7. 8. 2 9. PRODUCT FEATURES Ignitor Button Control Knob LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANSZ223.1, also known as NFPA 54*. *Available from : American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 Grill Burners QUALIFIED INSTALLING AGENCY Heater Cabinet Lower Front Panel Installation and replacement of gas piping, gas utillzation equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm , corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing , or replacement of gas piping or (b) the connection , installation , testing , repair , or servicing of equipment ; that is experienced in such work; that is familiar with all precautions required , and that has complied with all the requirements of the authority having jurisdiction. Figure1-Vent-Free Natural Gas Heater SAFETY DEVICE A standard requirement for all vent-free room heaters. This heater has a pilot with an Oxygen Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. State of Massachsetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts . Sellers of unvented propane or natural gas-fired PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor. This system requires no matches, batteries, or other sources to light heater. supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the THERMOSTATIC HEAT CONTROL ON THERMOSTAT MODELS nature gas-fired space heaters shall be prohibited in These heaters have a control valve with a thermostat sensing bulb. This results in the greatest heater comfort and may result in lower gas bills. 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. unit. In the state of Massachusetts, unvented propane or bedrooms and bathrooms. UNPACKING WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion.An unvented room heater productes approximately one (1) ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house) .In most supplemental heat application, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather. 3 The following steps will help insure that water vapor does not become a problem. 1. Be sure the heater is sized properly for the application, including ample combustion air and circulation air. 2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air. 3. Do not use an unvented room heater as the primary heat source. FRESH AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Section 5.3. Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 4 through 6 will help you classify your space and provide adequate ventilation. Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6×10-11 kg per pa-sec-m 2 ) or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, pages 5 and 6. If your home does not meet all of the three criteria above, see Determining Fresh-Air Flow for Heater Location, page 4, 5 Confined and Unconfined Space The National Fuel Gas Code ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space. This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. * Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them. DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if you Have a Confined or Unconfined Space* Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length×width×height). Length×Width×Height= cu.ft. (volume of space) Example: Space size18ft.(length)×16ft.( width)×8ft. (ceiling height)=23040cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support. (volume of space) 50 cu. ft.=(Maximum Btu/Hr the space can support) Example: 2304 cu. ft. (volume of space) 50 cu.ft.=46.1 or 46.100(maximum Btu/Hr the space can support) WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes. 4 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Example: Gas water heater* Btu/Hr Gas water heater 40,000 Btu/Hr Gas furnace Btu/Hr Vent free heater + 10,000 Btu/Hr Vented gas heater Btu/Hr total = 50,000 Btu/Hr Gas Fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr *Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used. Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example : 46,100 Btu/Hr(maximum the space can support) 50,000 Btu/Hr(actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 5. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6 . C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined. If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation. AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1. Section 5.3, Air for Combustion and Ve n t i l a t i o n f o r r e q u i r e d s i z e o f ventilation grills or ducts WARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces. Figure 2 -Ventilation Air from Inside Building 5 VENTILATION AIR Figure 3 -Ventilation Air from Outdoors INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source. WARNING: A qualified service person must install heater. Follow all local codes. CHECK GAS TYPE Use only natural gas. If your gas supply is not natural, do not install heater. Call dealer where you bought heater for proper type heater. Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3. Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent. INSTALLATION NEEDS Before installing heater, make sure you have the items listed below. piping (check local codes) sealant (resistant to natural gas) equipment shutoff valve* ground joint union test gauge connection* sediment trap tee joint pipe wrench *A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA/AGA design certified equipment shutoff valve from your dealer. LOCATING HEATER This heater is designed to be mounted on a wall. For convenience and efficiency, install heater where there is easy access for operation, inspection, and service. in coldest part of room. CAUTION: If you install the heater in a home garage heater pilot and burner must be at least 18 inches above floor. locate heater where moving vehicle will not hit it. 6 WARNING: Never install the heater in a bathroom(Models HR10MN and HR10TN , only HR06MN is allowed in a bathroom. Check local codes.) in a recreational vehicle. where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater. as a fireplace insert. in high traffic areas. in windy or drafty areas. When the HR06MN is installed in bathrooms,do not use flammable products such as aerosol hair spray, foot spary or any product that contains flammable vapors and keep towels away from heater.(only HR06MN is allowed in a bathroom.) CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist may discolor walls. INSTALLATION WARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall. Removing Lower Front Panel Of Heater 1. Remove two screws near bottom corners of lower front panel. 2. Pull bottom of lower front panel forward, then down (see Figure 6). Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry). Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket. Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level. Figure 4 -Mounting Clearances As Viewed From Front Of Heater FASTENING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater (see Figure 5). It has been taped there for shipping. Remove mounting bracket from back panel. Figure 6 - Removing Lower Front Panel Of Heater Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall. Attach mounting bracket to wall only in one of two ways: 1. Attaching to wall stud 2. Attaching to wall anchor Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs. WARNING: Maintain minimum clearances shown in Figure 4. If you can, provide greater clearances from floor and joining wall. 2. Mark screw locations on wall. (see Figure 7) Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall. Figure 7 - Mounting Bracket Clearances Figure 5 -Mounting Bracket Location 7 INSTALLATION Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64" drill bit. 2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall. 3. Insert mounting screws through bracket and into wall studs. 4. Tighten screws until mounting bracket is firmly fastened to wall studs. Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2. Fold wall anchor as shown in Figure 8 below. Figure 9 - Popping Open Anchor Wing For Thin Walls 5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is firmly fastened to wall. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. Placing Heater on Mounting Bracket 1. Locate two horizontal slots on back panel of heater (see Figure 10). 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket. Figure 8 - Folding Anchor 3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to "pop" open anchor wings. (see Figure 9). Figure 10 - Mounting Heater Onto Mounting Bracket 8 Installing Bottom Mounting Screws 1. Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 11). 2. Mark screw locations on wall. 3. Remove heater from mounting bracket. Figure 11 - Installing Bottom Mouting Screw 4. If installing bottom mounting screw into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attach ing to Wall Anchor Method. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacers between bottom mounting holes and wall anchor or drilled hole. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole. 8. Tighten screw until heater is firmly secured to wall. Do not over tighten. Note: Do not replace lower front panel at this time. Replace lower front panel after making gas connections and checking for leaks (see page 9). INSTALLATION CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator. WARNING: Never connect heater to private (non-utility) gas well. This gas is commonly known as well-head gas. IMPORTANT: Check your gas line pressure before connecting heater to gas line. Gas line pressure must be no greater than 10.5 inches of water. If gas line pressure is higher, heater regulator damage could occur. Figure 12 -Gas Connection CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur. Typical Inlet Pipe Diameters All models up to 20,000 BTU’s use 3/8’’ or greater pipe; All models 25,000 BTU’s and higher, use 1/2” or greater pipe. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 12). *A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA/AGA design-certified equipment shutoff valve from your dealer. IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. Install sediment trap in supply line as shown in Figure 12. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly. CAUTION: Use pipe joint sealant that is resistant to natural gas. IMPORTANT : Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. In the State of Massachusetts the gas cock must be a T handle type. The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length. 9 INSTALLATION CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 K Pa) OPERATING YOUR HEATER Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 13). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 14 ). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 10,11 and 12) Check the rest of the internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, pages 11 and 12) . 8. Replace lower front panel. 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 4. Check all joints of gas supply Figure 13-Equipment Shutoff Valve piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 K Pa) 1. Close equipment shutoff valve (see Figure 13). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to equipment shutoff valve (see Figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once. Figure 14 -Checking Gas Joints 1 0 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result in causing property damage personal injury or loss of life. A. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. OPERATING Manual Control Models LIGHTING INSTRUCTIONS 1. 2. 3. 4. 5. STOP! Read the safety information on the side of heater. Check that gas supply to heater is on. Push in gas control knob slightly and turn clockwise to the OFF position (see Figures 15&16). Wait five (5) minutes to clear out any air. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on the side of the heater. If you do not smell gas, go to the next step. Push in gas control knob slightly and turn counterclockwise to“PILOT/IGN” and depress for five(5) seconds NOTE: The first time that the heater is operated after connecting the gas supply , the control knob should be depressed for about thirty (30) seconds. This will allow air to bleed from the gas system. 6. With control knob pressed in, push down and release the ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights. 7. Keep control knob depressed for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 5,6 and 7. 8. To select the desired heating level, partially press down the control knob slightly and rotate counterclockwise . Release the d ownward pressure on the knob while continuing to turn until the knob locks at the desired setting position. Do not operate between locked positions. YOUR HEATER TO SELECT HEATING LEVEL WARNING: When running heater,set control knob at ON, LOW, or HIGH locked positions(see Figures 18 & 19). Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result. CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve. HR06MN Figure 18 - Burner Patterns HR10MN Slightly press in control knob and turn counterclockwise to the ON, LOW or HIGH positions (see Figures 18 & 19). Figure 19 - Burner Patterns Figure15-Control Knob In The OFF Position HR06MN Figure16-Control Knob In The OFF Position HR10MN TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (Pilot Stays Lit) Turn control knob clockwise to the PILOT/IGN position. MANUAL LIGHTING PROCEDURE Figure 17 - Pilot 1 1 1. Remove lower front panel (see Figure 6 page 7) 2. Follow steps 1 through 5 under Lighting Instructions. 3. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.Follow step 8 under Lighting Instructions. 5. Replace lower front panel. OPERATING YOUR HEATER THERMOSTAT MODEL HR10TN FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. 4. Wait five(5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on the side of heater. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockto the PILOT position. wise Press in control knob for five(5) seconds. (see Figure 20). Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system. If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, refer to Troubleshooting , pages 14 through 16. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match.To light pilot with match, see Manual Lighting Procedure. 7. Keep control knob pressed in for 30 seconds after lighting pilot.After 30 seconds, release control knob. If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electric switch, do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it , call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service Note: If pilot goes out,repeat steps 3 through 7.This heater has a safety technician to inspect the appliance interlock system. Wait one(1) and to replace any part of the control minute before lighting pilot again. system and any gas control which 8. Turn control knob counter clockhas been under water. wise to desired seating level. The main burner should LIGHTING INSTRUCTIONS 1. 2. 3. STOP! Read the safety information on the side of heater. Make sure equipment shutoff valve is fully open. Turn control knob clockwise to the OFF position. light. Set control knob to any heat level between HI and LO. (see Figure 22) CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve. 1 2 Figure 20 - Control Knob In The OFF Position HR10TN Figure 21 - Pilot Figure 22 - Burner Partterns THERMOSTAT CONTROL OPERATION The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so,the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set t o any comfort level between HI and LO. Note: The thermostat sensing bulb measures the temperature of air near the heater cabinet.This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatres,etc.) Frequent use of your heater will let you determine your own comfort levels. TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit ) Turn control knob clockwise to the PILOT position. OPERATING HEATER Continued MANUAL LIGHTING PROCEDURE 1. 2. 3. 4. 5. Remove lower front panel (see Figure 7 page 7). Follow steps 1 through 5 under Lighting Instructions on page12. With control knob pressed in, strike match. Hold match to pilot until pilot lights. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.Follow step 8 under Lighting Instuctions on page 12. Replace lower front panel. BURNER FLAME PATTERN Figure 25 shows a correct burner flame pattern. Figure 26 shows an incorrect burner flame pattern. If burner flame pattern is incorect, as shown in Figure 26 turn heater off(see To Turn Off Gas to Appliance pages 11&12) see Troubleshooting, pages 14 through 16) INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 24. turn heater off (see To Turn Off Gas to Appliance. pages 11,12 see Troubleshooting. pages 14 through 16. Figure 25 - Correct Burner Flame Pattern Figure 26 - Incorrect Burner Flame Pattern ODS/PILOT AND BURNER Use a vacuum cleaner, pressurized air, or a small, soft bristled brush to clean. CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit every 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSl. Your local computer store, hardware store. or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, and pilot for dust and dirt. 3. Blow air through the ports/slots and holes in the bumer. Also clean the pilot assembly. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 27). With the unit off , lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available. CLEANING AND MAINTENANCE Figure 23 - Correct Pilot Flame Pattern WARNING: turn off heater and let cool before cleaning. Figure 24 - Incorrect Pilot Flame Pattern CAUTION: you must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc. Figure 27 - Pilot Air Inlet Hole 1 3 CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean. Exterior Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust. TROUBLESHOOTING Note : All troubleshooting items are listed in order of operation. WARNING: Only a qualified service person should service and repair heater. OBSERVED PROBLEM POSSIBLE CAUSE When ignitor button is pressed and 1. Ignitor electrode is positioned control knob is pressed in and turned to wrong. the PILOT position, there is no spark 2. Ignitor electrode is broken. at ODS/pilot. 3. Ignitor electrode is not connected to ignitor cable. 4. Ignitor cable is pinched or wet. 5. Broken ignitor cable. 6. Bad piezo ignitor. When ignitor button is pressed and control knob is press in and turned to the PILOT position, there is a spark at ODS/pilot but no ignition. 1. Gas supply turned off or equipment shutoff valve is closed. 2. Control knob not fully pressed in while pressing ignitor button. 3. Air in gas lines when installed. 4. ODS/pilot is clogged. 5. Gas regulator setting is not correct. 6. Control knob not in PILOT position. ODS/pilot lights but flame goes out 1. Control knob is not fully pressed in. when control knob is released. 2. Control knob is not pressed in long enough. 3. Equipment shutoff valve is not fully open. 4. Thermocouple connection is loose at control valve. 5 Pilot flame is not touching thermocouple, This allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/ pilot 6. Thermocouple damaged. 7. Control valve damaged. 1 4 CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit. REMEDY 1. Replace ignitor. 2. Replace ignitor. 3. Reconnect ignitor cable. 4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry. 5. Replace ignitor cable. 6. Replace piezo ignitor. 1. Turn on gas supply of open equipment shutoff valve. 2. Fully press in control knob while pressing ignitor button. 3. Continue holding down control knob. Repeat igniting operation until air is removed. 4. Clean ODS/pilot (see Cleaning and Maintenance, Page 13) or replace ODS/pilot assembly. 5. Replace gas regulator. 6. Turn control knob to PILOT position. 1. Press in control knob fully. 2. After ODS/pilot lights, keep control knob pressed in 30 seconds. 3. Fully open equipment shutoff valve. 4. Hand tighten until snug, then tighten 1/4 turn more. 5. A) Contact local natural gas company. B) Clean ODS/pilot (see Cleaning and Maintenance, Page 13) or replace ODS/pilot assembly. 6. Replace thermocouple. 7. Replace control valve. TROUBLESHOOTING Continued REMEDY POSSIBLE CAUSE OBSERVED PROBLEM Burner(s)does not light after ODS/pilot is lit. 1. Burner orifice is clogged. 2. Burner orifice diameter is too small. 3. Inlet gas pressure is too low. 1. Clean burner orifice (see Cleaning and Maintenance, Page 13) or replace burner orifice. 2. Replace burner orifice. 3. Contact local natural gas company. Delayed ignition of burner(s). 1. Manifold pressure is too low. 2. Burner orifice is clogged. 1. Contact local natural gas company. 2. Clean burner (see Cleaning and Maintenance, Page 13) or replace burner orifice. Burner backfiring during combustion. 1. Burner orifice is clogged or damaged. 2. Burner is damaged. 3. Gas regulator is defective. 1. Clean burner orifice (see Cleaning and Maintenance, Page 13) or replace. 2. Replace burner. 3. Replace gas regulator. 1. Plaque damaged. 2. Inlet gas pressure is too low. 1. Replace burner. 2. Contact local natural gas company. 3. Control knob set between locked positions. 3. Turn control knob until it locks at desired setting. 1. Residues from manufacturing processes. 1. Problem will stop after a few hours of operation. Heater produces clicking/ticking noise just after burner is lit or shut off. 1. Metal is expanding while heating or contracting while cooling. 1. This is common with most heaters. If noise is excessive, contact qualified service person. White powder residue forming within burner box or on adjacent walls or furniture. 1. When heated, the vapors from furniture polish, wax, carpet cleaners, etc. turn into white powder residue. 1. Burner plaque(s) does not glow. Slight smoke or initial operation. odor during 1 5 Turn heater off when using furniture polish, wax, carpet cleaner, or similar products. TROUBLESHOOTING Continued WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. REMEDY POSSIBLE CAUSE OBSERVED PROBLEM Heater produces unwanted odors. Heater shuts off in use (ODS operates). 1. Heater is burning vapors from paint, hair spray, glues, etc. (See IMPORTANT statement above). 2 . G a s l e a k . S e e Wa r n i n g Statement at top of page. 1. Ventilate room. Stop using odor causing products while heater is running. 2. Locate and correct all leaks(see Checking Gas Connections, page 10). 1. Not enough fresh air is available. 1. 2. Low line pressure. 3. ODS/pilot is partially clogged. Open window and/or door for ventilation. 2. Contact local natural gas company. 3. Clean ODS/pilot (see Cleaning page 13). 2. Control valve is defective. Locate and correct all leak s(see Checking Gas Connections, page 10). 2. Replace control valve. Gas odor exists during combustion. 1. Foreign matter between control valve and burner. 2. Gas leak. See Warning Statement at top of page. 1. Moisture/condensation windows. 1. 1. Gas odor even when control knob is in OFF position. noticed on 1. Gas leak. See Warning Statement at top of page. Not enough combustion/ventilation air. 1 6 1. Take apart gas tubing and remove foreign matter. 2. Locate and correct all leaks (see Checking Gas Connections, page 10). Refer to Air for Combustion and Ventilation Requirements, page 4. SPECIFICATIONS Btu(available) Gas Type Ignition Pressure Regulator setting Inlet Gas Pressure* (inches of water) Maximum Minimum Dimensions, Inches (HxWxD) Heater Carton Weight (pounds) Heater Shipping HR06MN 6,000 Natural Only Piezo 6" W.C. HR10MN 5,500/10,000 Natural Only Piezo 6" W.C. HR10TN 10,000 Natural Only Piezo 6" W.C. 10.5" 7" 10.5" 7" 10.5" 7" 19×14-1/4×7 22×16-3/4×8-1/8 19×14-1/4×7 22×16-3/4×8-1/8 19×14-1/4×7 22×16-3/4×8-1/8 12 15 13 16 13 16 Note: Dimensions listed are outer most points on the heater (includes control knobs and grill). * For purposes of input adjustment. REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call the number on the front of this manual. When contacting your dealer or HearthRite, have ready: your name your address model and serial numbers of your heater how heater was malfunctioning type of gas used (propane/LP or natural gas) purchase date warranty card Usually, we will ask you to return the defective part to the factory. ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, contact HearthRite for information. You can also write to the address listed on the front of this manual. FLOOR MOUNTING STAND For locating heater on the floor away from a wall. Complete installation instructions provided with floor mounting stand. PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), contact HearthRite at (800)851-3153. TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact HearthRite at (800)851-3153. A Division of Empire Comfort Systems,Inc. 918 Freeburg Avenue Belleville,IL 62220 1 7 Phone : 618-233-7420 or 1-800-851-3153 Fax : 618-233-7097 or 1-800-443-8648 www.hearthrite.com ILLUSTRATED PARTS BREAKDOWN HR06MN 1 8 PARTS LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual. HR06MN KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 PART NUMBER DESCRIPTION MB10008E MB09003E ML006-02E MB19007 ND1206x600x9 ND0803-6 ND0807-B2 ML026-03 ML069-02 NV2020-12 ML073-01 ML029-01 MB40051 MB40052 MB40053 ML090-03 MB16002 NRV81FI-6 ML129-02 ML079-01 ML119-01 ML057-04 ML060-02 ML083-03 Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screws Control Valve Ignitor Line Control Valve Fixed Nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Line Assembly Injector Control Knob Assembly Pressure Regulator Regulator Mounting Bracket Self Locking Screws Pressure Tap Grill Guard Mounting Bracket lgnitor Assembly QTY 1 1 1 1 1 1 1 1 10 1 1 1 1 1 1 1 1 1 1 4 1 1 1 1 PARTS AVAILABLE NOT SHOWN MB28001 ML070-31E Assembly Hardware CSA/AGA Label 1 9 1 1 ILLUSTRATED PARTS BREAKDOWN HR10MN 2 0 PARTS LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 17 of this manual. HR10MN KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PART NUMBER DESCRIPTION MB10008E MB09003E ML006-01E MB19005 ND1206x600x9 ND0803-6 ND0807-B2 ML026-02 ML069-02 NV2020-13 ML073-01 ML029-01 MB40033 MB40034 MB40035 MB40036 ML090-03 MB16002 NRV81FI-6 ML129-02 ML079-01 ML119-01 ML057-04 ML060-02 ML083-03 Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS pilot Assembly Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screws Control Valve Ignitor line Control Valve Fixed Nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Line Assembly A Burner Gas Line Assembly B Injector Control Knob Assembly Pressure Regulator Regulator Mounting Bracket Self Locking Screws Pressure Tap Grill Guard Mounting Bracket lgnitor Assembly QTY 1 1 1 1 1 1 1 1 10 1 1 1 1 1 1 1 2 1 1 1 4 1 1 1 1 PARTS AVAILABLE NOT SHOWN MB28001 ML070-01E Assembly Hardware CSA/AGA Label 2 1 1 1 ILLUSTRATED PARTS BREAKDOWN HR10TN 2 2 PART LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 17 of this manual. HR10TN KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PART NUMBER MB10007E MB09003E ML006-01E MB19005 ND1206x600x9 ND0803-6 ND0807-B2 ML026-02 ML069-02 845-4.8x60Z SIT544-000 ML111-02 ML056-03 MB40037 MB40039 MB40038 MB40040 ML090-03 MB40041 NRV81FI-6 ML129-02 ML079-01 ML057-04 ML060-02 ML083-03 DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screws Screws Thermostat Valve Assembly Thermostat Valve Base/Bracket “T” Joint Main Inlet Tube Assembly ODS Gas Line Assembly Main Outlet Tube Assembly Burner Gas Line Assembly A Injector Burner Gas Line Assembly B Pressure Regulator Regulator Mounting Bracket Self Locking Screws Grill Guard Mounting Bracket lgnitor Assembly QTY 1 1 1 1 1 1 1 1 10 1 1 1 1 1 1 1 1 2 1 1 1 4 1 1 1 PARTS AVAILABLE NOT SHOWN MB28001 ML070-29E Assembly Hardware CSA/AGA Label 2 3 1 1 2 4
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project