Empire HR06, 10 HearthRite Infrared Heater Owner's Operation And Installation Manual


Add to my manuals
24 Pages

advertisement

Empire HR06, 10 HearthRite Infrared Heater Owner's Operation And Installation Manual | Manualzz
INFRARED VENT-FREE
NATURAL GAS
SPACE HEATER
OWNER ’S OPERATION AND INSTALLATION MANUAL
HR06MN-1 HR10MN-1 HR10TN-1
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified installer, service agency or gas
supplier.
Table of Contents
Important Safety Information.................................2
Product Features.....................................................3
Proper Ventilation & Fresh Air..............................4
Installation................................................................6
Operating Your Heater............................................10
Cleaning & Maintenance.......................................13
Trouble Shooting...................................................14
Specifications..........................................................17
Parts List..................................................................19
Warranty Information...........................................24
WARNING: If the information in this
manual is not followed exactly, a f i r e o r
e x p l o s i o n m a y r e s u l t causing property
damage, personal injury, or loss of life.
WARNING: This is an unvented gasfired heater. It uses air (oxygen) f r o m t h e
r o o m i n w h i c h i t i s installed. Provisions for adequate combustion and ventilation air must b e p r o v i d e d . R e f e r t o A i r
F o r Combustion and Ventilation section on
page 4 of this manual.
A Division of Empire Comfort Systems,Inc.
918 Freeburg Avenue
Belleville,IL 62220
Phone : 618-233-7420 or 1-800-851-3153
Fax : 618-233-7097 or 1-800-443-8648
www.hearthrite.com
WA R N I N G : I m p r o p e r
installation,
adjustment, alteration, service or maintenance can cause injury or property damage.
Refer to this manual for correct installation and
operational procedures. For assistance or
additional information consult a qualified
installer, service agency, or gas supplier.
This appliance may be installed in an aftermarket* permanently located, manufactured
(mobile) home, where not prohibited by local
codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM
HEATERS
Water vapor is a by-product of gas combustion.An
unvented room heater productes approximately one (1)
ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of
gas input per hour. Refer to page 3.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
Installer: Please leave these instructions with the
consumer.
Consumer: Please retain these instructions for
future use.
IMPORTANT
SAFETY INFORMATION
WARNINGS
I M P O R TA N T: R e a d t h i s
owner’s manual carefully and
completely before trying to
assemble, operate, or service
this heater. Improper use of
this heater can cause serious
injury or death from burns,
fire,
explosion,
electrical
shock, and carbon monoxide
poisoning.
WARNING: Do not use any
accessory not approved for
use with this heater.
WARNING: Any change to
this heater or its controls can
be dangerous.
Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.
1.
2.
3.
4.
Due to high temperatures, heater
should
be
kept
out
of
traffic and away from furniture
and draperies.
Surface of heater becomes
very hot when running heater.
Keep children and adults away
from hot surface to avoid burns
or clothing ignition. Heater will
remain hot for a time after shut
down. Allow surface to cool
before touching.
Carefully supervise young
children when they are in the
same room with heater.
Make
place
sure grill guard is in
before running heater.
Always run heater with control
knob at ON, LOW or HIGH
locked positions. Never set
control knob between locked
positions. Poor combustion
This appliance is only for use
and higher levels of carbon
with the type of gas indicated
monoxide may result.
on the rating plate. This
10. Do not use heater if any part
appliance is not convertible for
has been under water.
use with other gases.
Immediately call a qualified
If you smell gas
service technician to inspect
Shut off gas supply.
the room heater and to
Do not try to light any appliance.
replace any part of the control
Do not touch any electrical switch,
system and any gas control
do not use any phone in your
which has been under water
building.
11. Turn off heater and let cool
Immediately call your gas supbefore servicing. Only a qualified
plier from a neighbor’s phone.
service person should service
Follow the gas supplier’s
and repair heater.
instructions.
12. Operating heater above
If you cannot reach your gas
elevations of 4,500 feet could
supplier, call the fire
cause pilot outage.
department.
Do not install models HR10MN
DANGER: Carbon monoxide
and HR10TN in a bathroom.
poisoning may lead to death!
This heater needs fresh,
Carbon Monoxide Poisoning.
outside air ventilation to run
Early signs of carbon monoxide
properly. This heater has an
poisoning resemble the flu with
Oxygen Depletion Sensor
headaches, dizziness, or nausea
(ODS) safety shutoff system.
If you have these signs, the heater
The ODS shuts down the
may not be working properly. Get
heater if not enough fresh air
fresh air at once! Have heater
is available. See Fresh Air For
serviced. Some people are more
Combustion And Ventilation
affected by carbon monoxide than
pages 4 through 6
others. These include pregnant
Keep all air openings in the
women, persons with heart or lung
front and bottom of heater
disease or anemia, those under the
clear and free of debris. This
influence of alcohol, and those
will insure enough air for
at high altitudes.
proper combustion
Natural Gas: Natural gas is
If heater shuts off. Do not
odorless. An odor-making agent is
relight until you provide fresh,
added to natural gas. The odor
outside air. If heater keeps
helps you detect a natural gas leak .
shutting off, have it serviced.
However, the odor added to natural
Do not operate heater
gas can fade. natural gas may be
where flammable liquids or
present even though no odor exists.
vapors are used or stored
Make certain you read and underunder dusty conditions
stand
all
warnings. Keep
Turn heater off before using
this
manual
for
reference. It is your
furniture polish, wax, carpet
guide
to
safe
and
proper operation
cleaner, or similar products. If
of
this
heater.
heated, the vapors from these
products may create a white
powder residue within burner
box or on adjacent walls or
furniture.
Keep the appliance area clear
and free from combustible
materials, gasoline, and other
flammable vapors and liquids.
5.
6.
7.
8.
2
9.
PRODUCT FEATURES
Ignitor
Button
Control
Knob
LOCAL CODES
Install and use heater with care. Follow all local
codes. In the absence of local codes, use the
latest edition of National Fuel Gas Code ANSZ223.1,
also known as NFPA 54*.
*Available from :
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Grill
Burners
QUALIFIED INSTALLING AGENCY
Heater
Cabinet
Lower
Front
Panel
Installation and replacement of gas piping, gas
utillzation equipment or accessories and repair and
servicing of equipment shall be performed only by a
qualified agency. The term “qualified agency” means
any individual, firm , corporation, or company that
either in person or through a representative is
engaged in and is responsible for (a) the installation,
testing , or replacement of gas piping or (b) the
connection , installation , testing , repair , or servicing
of equipment ; that is experienced in such work; that
is familiar with all precautions required , and that has
complied with all the requirements of the authority
having jurisdiction.
Figure1-Vent-Free Natural Gas Heater
SAFETY DEVICE
A standard requirement for all vent-free room
heaters. This heater has a pilot with an Oxygen
Depletion Sensor(ODS) safety shutoff system.
The ODS/pilot shuts off the heater if there is
not enough fresh air.
State of Massachsetts: The installation must be
made by a licensed plumber or gas fitter in the
Commonwealth of Massachusetts .
Sellers of unvented propane or natural gas-fired
PIEZO IGNITION SYSTEM
This heater is equipped with a piezo ignitor.
This system requires no matches, batteries, or
other sources to light heater.
supplemental room heaters shall provide to each
purchaser a copy of 527 CMR 30 upon sale of the
THERMOSTATIC HEAT
CONTROL ON THERMOSTAT
MODELS
nature gas-fired space heaters shall be prohibited in
These heaters have a control valve with a
thermostat sensing bulb. This results in the
greatest heater comfort and may result in
lower gas bills.
1. Remove heater from carton.
2. Remove all protective packaging applied to
heater for shipment.
3. Check heater for any shipping damage. If heater
is damaged, promptly inform dealer where you
bought heater.
unit.
In the state of Massachusetts, unvented propane or
bedrooms and bathrooms.
UNPACKING
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion.An
unvented room heater productes approximately one (1)
ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of
gas input per hour.
Unvented room heaters are recommended as
supplemental heat (a room) rather than a primary heat
source (an entire house) .In most supplemental heat
application, the water vapor does not create a problem.
In most applications, the water vapor enhances the low
humidity atmosphere experienced during cold weather.
3
The following steps will help insure that water vapor
does not become a problem.
1. Be sure the heater is sized properly for the
application, including ample combustion air and
circulation air.
2. If high humidity is experienced, a dehumidifier may
be used to help lower the water vapor content of the
air.
3. Do not use an unvented room heater as the primary
heat source.
FRESH AIR FOR
COMBUSTION AND
VENTILATION
WARNING: This heater
shall not be installed in a
confined space or unusually
tight
construction
unless
provisions are provided for
adequate
combustion
and
ventilation air. Read the
following instructions to
insure proper fresh air for this
and
other
fuel-burning
appliances in your home.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from
National Fuel Gas Code. NFPA
54/ANS Z223.1, Section 5.3. Air for
Combustion and Ventilation. All
spaces in homes fall into one of
the three following ventilation
classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 4
through 6 will help you classify
your space and provide adequate
ventilation.
Unusually Tight Construction
The air that leaks around doors and
windows may provide enough fresh
air for combustion and ventilation.
However, in buildings of unusually
tight construction, you must provide
additional fresh air.
Unusually tight construction is
defined as construction where:
a. walls and ceilings exposed to the
outside
atmosphere
have
a
continuous water vapor retarder
with a rating of one perm (6×10-11 kg
per pa-sec-m 2 )
or less with
openings gasketed or sealed and
b. weather stripping has been
added on openable windows and
doors and
c. caulking or sealants are applied
to areas such as joints around
window and door frames, between
sole plates and floors, between
wall-ceiling joints, between wall
panels, at penetrations for plumbing,
electrical, and gas lines, and at
other openings. If your home meets
all of the three criteria above, you
must provide additional fresh air.
See Ventilation Air From Outdoors,
pages 5 and 6. If your home does
not meet all of the three criteria
above, see Determining Fresh-Air
Flow for Heater Location, page 4, 5
Confined and
Unconfined Space
The National Fuel Gas Code
ANS Z223.1 defines a confined
space as a space whose volume
is less than 50 cubic feet per
1,000 Btu per hour (4.8 m3 per kw)
of the aggregate input rating of all
appliances installed in that space
and an unconfined space as a
space whose volume is not less
than 50 cubic feet per 1,000 Btu
per hour (4.8 m3 per kw) of the
aggregate input rating of all
appliances installed in that space.
Rooms communicating directly
with the space in which the
appliances are installed*, through
openings not furnished with
doors, are considered a part of
the unconfined space.
This heater shall not be installed
in a confined space or unusually
tight construction unless
provisions are provided for
adequate
combustion
and
ventilation air.
* Adjoining rooms are
communicating only if there are
doorless passageways or
ventilation grills between them.
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if you Have a Confined or Unconfined Space*
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways
or ventilation grills between the rooms.
1. Determine the volume of the space (length×width×height).
Length×Width×Height=
cu.ft. (volume of space)
Example: Space size18ft.(length)×16ft.( width)×8ft. (ceiling height)=23040cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these
rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
(volume of space) 50 cu. ft.=(Maximum Btu/Hr the space can support)
Example: 2304 cu. ft. (volume of space) 50 cu.ft.=46.1 or 46.100(maximum Btu/Hr the space can support)
WARNING: If the area in which the heater may be operated is smaller than that defined as an
unconfined space or if the building is of unusually tight construction, provide adequate combustion and
ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3
or applicable local codes.
4
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater
Btu/Hr
Example:
Gas water heater*
Btu/Hr
Gas water heater
40,000
Btu/Hr
Gas furnace
Btu/Hr
Vent
free
heater
+
10,000
Btu/Hr
Vented gas heater
Btu/Hr
total
=
50,000
Btu/Hr
Gas Fireplace logs
Btu/Hr
Other gas appliances* +
Btu/Hr
Total
=
Btu/Hr
*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and
vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
Btu/Hr (maximum the space can support)
Btu/Hr (actual amount of Btu/Hr used)
Example : 46,100 Btu/Hr(maximum the space can support)
50,000 Btu/Hr(actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the
maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined
space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From
Inside Building, page 5.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6 .
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an
unconfined space. You will need no additional fresh air ventilation.
AIR FOR COMBUSTION AND
VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an
adjoining unconfined space. When
ventilating to an adjoining unconfined
space, you must provide two permanent
openings: one within 12" of the ceiling
and one within 12" of the floor on the
wall connecting the two spaces (see
options 1 and 2, Figure 2). You can also
remove door into adjoining room (see
option 3, Figure 2). Follow the National
Fuel Gas Code NFPA 54/ANS Z223.1.
Section 5.3, Air for Combustion and
Ve n t i l a t i o n f o r r e q u i r e d s i z e o f
ventilation grills or ducts
WARNING: Rework worksheet, adding the space of the adjoining
unconfined space. The combined spaces
must have enough fresh air to supply all
appliances in both spaces.
Figure 2 -Ventilation Air from Inside Building
5
VENTILATION AIR
Figure 3 -Ventilation Air from Outdoors
INSTALLATION
NOTICE: This heater is
intended for use as supplemental
heat. Use this heater along with
your primary heating system. Do
not install this heater as your
primary heat source. If you have
a central heating system, you
may run system’s circulating
blower while using heater. This
will help circulate the heat
throughout the house. In the
event of a power outage, you can
use this heater as your primary
heat source.
WARNING: A qualified
service person must install
heater. Follow all local codes.
CHECK GAS TYPE
Use only natural gas. If your
gas supply is not natural, do
not install heater. Call dealer
where you bought heater for
proper type heater.
Ventilation Air From Outdoors
Provide extra fresh air by using
ventilation grills or ducts: You must
provide two permanent openings: one
within 12" of the ceiling and one within
12" of the floor.
Connect these items directly to the
outdoors or spaces open to the outdoors.
These spaces include attics and crawl
spaces. Follow the National Fuel Gas
Code NFPA 54/ANS Z223.1, Section 5.3.
Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
IMPORTANT: Do not provide openings
for inlet or outlet air into attic if attic has
a thermostat-controlled power vent.
Heated air entering the attic will activate
the power vent.
INSTALLATION NEEDS
Before installing heater, make sure
you have the items listed below.
piping (check local codes)
sealant (resistant to natural
gas)
equipment shutoff valve*
ground joint union
test gauge connection*
sediment trap
tee joint
pipe wrench
*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to
test gauge connection. Purchase
the CSA/AGA design certified
equipment shutoff valve from your
dealer.
LOCATING HEATER
This heater is designed to be
mounted on a wall.
For convenience and efficiency,
install heater
where there is easy access for
operation, inspection, and service.
in coldest part of room.
CAUTION: If you install the
heater in a home garage
heater pilot and burner must
be at least 18 inches above
floor.
locate heater where moving
vehicle will not hit it.
6
WARNING: Never install
the heater
in a bathroom(Models
HR10MN and HR10TN , only
HR06MN is allowed in a
bathroom. Check local codes.)
in a recreational vehicle.
where curtains, furniture,
clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides
of the heater.
as a fireplace insert.
in high traffic areas.
in windy or drafty areas.
When the HR06MN is installed in
bathrooms,do not use flammable
products such as aerosol hair spray,
foot spary or any product that contains
flammable vapors and keep towels
away from heater.(only HR06MN is
allowed in a bathroom.)
CAUTION: This heater creates
warm air currents. These currents
move heat to wall surfaces next
to heater. Installing heater
next to vinyl or cloth wall coverings
or operating heater where impurities
(such as tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist
may discolor walls.
INSTALLATION
WARNING: Maintain the
minimum clearances shown
in Figure 4. If you can,
provide greater clearances from
floor, ceiling, and joining wall.
Removing Lower Front Panel Of
Heater
1. Remove two screws near
bottom corners of lower front
panel.
2. Pull bottom of lower front panel
forward, then down (see Figure
6).
Attaching to Wall Anchor: This
method allows you to attach
mounting bracket to hollow walls
(wall areas between studs) or to
solid walls (concrete or masonry).
Decide which method better
suits your needs. Either method
will provide a secure hold for the
mounting bracket.
Marking Screw Locations
1. Tape mounting bracket to wall
where heater will be located.
Make sure mounting bracket is
level.
Figure 4 -Mounting Clearances As
Viewed From Front Of Heater
FASTENING HEATER TO WALL
Mounting Bracket
The mounting bracket is located
on back panel of heater (see
Figure 5). It has been taped there
for shipping. Remove mounting
bracket from back panel.
Figure 6 - Removing Lower Front
Panel Of Heater
Methods For Attaching Mounting
Bracket To Wall
Only use last hole on each end
of mounting bracket to attach
bracket to wall. Attach mounting
bracket to wall only in one of two ways:
1. Attaching to wall stud
2. Attaching to wall anchor
Attaching to Wall Stud: This method
provides the strongest hold. Insert
mounting screws through mounting
bracket and into wall studs.
WARNING:
Maintain
minimum clearances shown in
Figure 4. If you can, provide
greater clearances from floor
and joining wall.
2. Mark screw locations on
wall. (see Figure 7)
Note: Only mark last hole on
each end of mounting bracket.
Insert mounting screws through
these holes only.
3. Remove tape and mounting
bracket from wall.
Figure 7 - Mounting Bracket
Clearances
Figure 5 -Mounting Bracket
Location
7
INSTALLATION
Attaching Mounting Bracket To
Wall
Note: Wall anchors, mounting
screws, and spacers are in
hardware package. The hardware
package is provided with heater.
Attaching to Wall Stud Method
For attaching mounting bracket to
wall studs
1. Drill holes at marked locations
using 9/64" drill bit.
2. Place mounting bracket onto
wall. Line up last hole on each
end of bracket with holes drilled
in wall.
3. Insert mounting screws through
bracket and into wall studs.
4. Tighten screws until mounting
bracket is firmly fastened to
wall studs.
Attaching to Wall Anchor Method
For attaching mounting bracket to
hollow walls (wall areas between
studs) or solid walls (concrete or
masonry)
1. Drill holes at marked locations
using 5/16" drill bit. For solid
walls (concrete or masonry),
drill at least 1" deep.
2. Fold wall anchor as shown in
Figure 8 below.
Figure 9 - Popping Open Anchor
Wing For Thin Walls
5. Place mounting bracket onto
wall. Line up last hole on
each end of bracket with wall
anchors.
6. Insert mounting screws through
bracket and into wall anchors.
7. Tighten screws until mounting
bracket is firmly fastened to
wall.
IMPORTANT: Do not
hammer
key! For thick walls
(over 1/2" thick) or solid walls,
do not pop open wings.
Placing Heater on Mounting
Bracket
1. Locate two horizontal slots on
back panel of heater (see
Figure 10).
2. Place heater onto mounting
bracket. Slide horizontal slots
onto stand-out
tabs
on
mounting bracket.
Figure 8 - Folding Anchor
3.
Insert wall anchor (wings
first) into hole. Tap anchor
flush to wall.
4. For thin walls (1/2" or less),
insert red key into wall
anchor. Push red key to
"pop" open anchor wings.
(see Figure 9).
Figure 10 - Mounting Heater Onto
Mounting Bracket
8
Installing Bottom Mounting
Screws
1. Locate bottom mounting hole. This
hole is near bottom on back
panel of heater (see Figure 11).
2. Mark screw locations on wall.
3. Remove heater from mounting
bracket.
Figure 11 - Installing Bottom
Mouting Screw
4. If installing bottom mounting
screw into hollow or solid wall,
install wall anchors. Follow
steps 1 through 4 under Attach
ing to Wall Anchor Method. If
installing bottom mounting screw
into wall stud, drill holes at
marked locations using 9/64"
drill bit.
5. Replace heater onto mounting
bracket.
6. Place spacers between bottom
mounting holes and wall anchor
or drilled hole.
7. Hold spacer in place with
one
hand. With other hand, insert
mounting screw through bottom
mounting hole and spacer. Place
tip of screw in opening of wall
anchor or drilled hole.
8. Tighten screw until heater is firmly
secured to wall. Do not over
tighten.
Note: Do not replace lower front
panel at this time. Replace lower
front panel after making gas
connections and checking for
leaks (see page 9).
INSTALLATION
CONNECTING TO GAS SUPPLY
WARNING: A qualified
service person must connect
heater to gas supply. Follow all
local codes.
WARNING: This appliance
requires a 3/8" NPT (National
Pipe Thread) inlet connection
to the pressure regulator.
WARNING: Never connect
heater to private (non-utility) gas
well. This gas is commonly
known as well-head gas.
IMPORTANT: Check your gas line
pressure before connecting heater
to gas line. Gas line pressure must
be no greater than 10.5 inches of
water. If gas line pressure is
higher, heater regulator damage
could occur.
Figure 12 -Gas Connection
CAUTION: Use only new,
black iron or steel pipe.
Internally-tinned copper tubing
may be used in certain areas.
Check your local codes. Use pipe
of large enough diameter to
allow proper gas volume to heater.
If
pipe
is
too
small,
undue loss of pressure will
occur.
Typical Inlet Pipe Diameters
All models up to 20,000 BTU’s use
3/8’’ or greater pipe;
All models 25,000 BTU’s and higher,
use 1/2” or greater pipe.
Installation must include an equipment shutoff valve, union, and
plugged 1/8" NPT tap. Locate NPT
tap within reach for test gauge hook
up. NPT tap must be upstream
from heater (see Figure 12).
*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is
an acceptable alternative to test gauge connection. Purchase the CSA/AGA
design-certified equipment shutoff valve from your dealer.
IMPORTANT: Install an equipment
shutoff valve in an accessible
location. The equipment shutoff
valve is for turning on or shutting
off the gas to the appliance.
Apply pipe joint sealant lightly to
male threads. This will prevent
excess sealant from going into
pipe. Excess sealant in pipe could
result in clogged heater valves.
Install sediment trap in supply line
as shown in Figure 12. Locate
sediment trap where it is within
reach
for cleaning. Locate
sediment
trap where trapped
matter is not likely to freeze. A
sediment trap traps moisture and
contaminants. This keeps them
from going into heater controls. If
sediment trap is not installed or is
installed wrong, heater may
not run properly.
CAUTION: Use pipe joint
sealant that is resistant to
natural gas.
IMPORTANT :
Hold pressure
regulator with wrench when
connecting it to gas piping and/or
fittings.
In the State of Massachusetts the
gas cock must be a T handle type.
The State of Massachusetts
requires that a flexible appliance
connector cannot exceed three
feet in length.
9
INSTALLATION
CHECKING GAS
CONNECTIONS
WARNING: Test all gas piping
and connections for leaks after
installing or servicing. Correct all
leaks at once.
WARNING: Never use an open
flame to check for a leak. Apply
a mixture of liquid soap and
water to all joints. Bubbles forming show a leak. Correct all leaks
at once.
Pressure Testing Gas Supply
Piping System
Test Pressures In Excess Of
1/2 PSIG (3.5 K Pa)
OPERATING YOUR HEATER
Pressure Testing Heater Gas
Connections
1. Open equipment shutoff valve
(see Figure 13).
2. Open main gas valve located on
or near gas meter.
3. Make sure control knob of
heater is in the OFF position.
4. Check all joints from equipment
shutoff valve to control valve
(see Figure 14 ). Apply mixture of
liquid soap and water to gas
joints. Bubbles forming show
a leak.
5. Correct all leaks at once.
6. Light heater (see Operating
Heater, pages 10,11 and 12)
Check the rest of the internal
joints for leaks.
7. Turn off heater (see To Turn Off
Gas to Appliance, pages 11 and
12) .
8. Replace lower front panel.
1. Disconnect appliance with its
appliance
main
gas valve
(control valve) and equipment
shutoff valve from gas supply
piping system. Pressures in
excess of 1/2 psig will damage
heater regulator.
2. Cap off open end of gas pipe
where equipment shutoff valve
was connected.
3. Pressurize supply piping system by either using compressed
air or opening
main gas valve located on or
near gas meter.
4. Check all joints of gas supply
Figure 13-Equipment Shutoff Valve
piping system. Apply mixture of
liquid soap and water to gas
joints. Bubbles forming show
a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment
shutoff valve to gas supply. Check
reconnected fittings for leaks.
Test Pressures Equal To or
Less Than 1/2 PSIG (3.5 K Pa)
1.
Close equipment shutoff valve
(see Figure 13).
2. Pressurize supply piping system
by either using compressed air
or opening main gas valve
located on or near gas meter.
3. Check all joints from gas meter
to equipment shutoff valve (see
Figure 14). Apply mixture of
liquid soap and water to gas joints.
Bubbles forming show a leak.
4. Correct all leaks at once.
Figure 14 -Checking Gas Joints
1 0
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not
follow these instructions exactly,
a fire or explosion may result
in causing property damage
personal injury or loss of life.
A. When lighting the pilot, follow
these instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for
gas. Be sure to smell next to
the floor because some gas is
heavier than air and will settle
on the floor .
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch;
do not use any phone in your
building.
Immediately
call
your gas
supplier from a neighbor’s
phone. Follow
the
gas
supplier’s instructions.
If you cannot reach your
gas supplier, call the fire
department.
C. Use only your hand to push in
or turn the gas control knob.
Never use tools. If the knob
will not push in or turn by
hand, don’t try to repair it, call
a qualified service technician or
gas supplier. Force or attempted
repair may result in a fire or
explosion.
D. Do not use this appliance if any
part has been under water.
Immediately call a qualified
service technician to inspect
the appliance and to replace
any part of the control system
and any gas control which has
been under water.
OPERATING
Manual Control Models
LIGHTING
INSTRUCTIONS
1.
2.
3.
4.
5.
STOP! Read
the safety
information on the side of
heater.
Check that gas supply to
heater is on.
Push in gas control knob
slightly and turn clockwise
to
the OFF position (see Figures
15&16).
Wait five (5) minutes to clear
out any air. Then smell for
gas, including near the floor.
If
you
smell gas, STOP!
Follow “B”
in
the
safety
information on the side of the
heater. If you do not smell
gas, go to the next step.
Push
in gas control knob
slightly and
turn counterclockwise
to“PILOT/IGN”
and depress for five(5) seconds
NOTE: The first time that the heater
is operated after
connecting
the gas supply , the
control knob
should be depressed for about thirty
(30) seconds. This will allow air to
bleed
from
the
gas
system.
6. With control knob pressed in,
push down and release the
ignitor button. This will light
pilot. If needed, keep pressing
ignitor button until pilot lights.
7. Keep control knob depressed
for ten (10) seconds after
lighting pilot. If pilot goes out,
repeat steps 5,6 and 7.
8. To select the desired heating
level, partially press down the
control knob slightly and rotate
counterclockwise
. Release the
d ownward pressure on the knob
while continuing to turn until the
knob locks at the desired setting
position. Do not operate
between locked positions.
YOUR
HEATER
TO SELECT
HEATING LEVEL
WARNING: When running
heater,set control knob at
ON, LOW, or HIGH locked
positions(see Figures 18 & 19).
Never set control knob between
locked positions. Poor combustion
and higher levels of carbon
monoxide may result.
CAUTION: Do not try to
adjust heating levels by using
the equipment shutoff valve.
HR06MN
Figure 18 - Burner Patterns
HR10MN
Slightly press in control knob
and turn counterclockwise
to the ON, LOW or HIGH
positions (see Figures 18 & 19).
Figure 19 - Burner Patterns
Figure15-Control Knob In The
OFF Position HR06MN
Figure16-Control Knob In The
OFF Position HR10MN
TO TURN OFF
GAS TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2. Turn off all electric power to
the appliance if service is to
be performed.
Shutting Off Burner Only (Pilot
Stays Lit)
Turn control knob clockwise
to the PILOT/IGN position.
MANUAL LIGHTING
PROCEDURE
Figure 17 - Pilot
1 1
1. Remove lower front panel (see
Figure 6 page 7)
2. Follow steps 1 through 5 under
Lighting Instructions.
3. With control knob pressed in,
strike match. Hold match to
pilot until pilot lights.
4. Keep control knob pressed in
for 30 seconds after lighting
pilot. After 30 seconds, release
control knob.Follow step 8 under
Lighting Instructions.
5. Replace lower front panel.
OPERATING YOUR HEATER
THERMOSTAT MODEL
HR10TN
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow
these instructions exactly, a fire or
explosion may result
causing
property damage, personal injury or
loss of life.
A.
This appliance has a pilot
which must be lighted by hand.
When lighting the pilot, follow these
instructions exactly.
B.
BEFORE LIGHTING smell all
around the appliance area for gas.
Be sure to smell next to the floor
because some gas is heavier than
air and will settle on the floor.
4. Wait five(5) minutes to clear
out any gas. Then smell for gas,
including near the floor. If you
smell gas, STOP! Follow “B” in the
safety information on the side of
heater. If you don’t smell gas,
go to the next step.
5. Turn control knob counterclockto the PILOT position.
wise
Press in control knob for five(5)
seconds. (see Figure 20).
Note: You may be running this
heater for the first time after
hooking up to gas supply. If so,
the control knob may need to be
pressed in for 30 seconds. This
will allow air to bleed from the
gas system.
If control knob does not pop
up when released, contact a
qualified service person or gas
supplier for repairs.
6. With control knob pressed in,
push down and release ignitor
button. This will light pilot. The
pilot is attached to the front of
burner. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer
to Troubleshooting , pages 14
through 16. Also contact a qualified service person or gas supplier for repairs. Until repairs are
made, light
pilot
with
match.To light pilot with match,
see Manual Lighting Procedure.
7. Keep control knob pressed in for
30 seconds after lighting pilot.After
30 seconds, release control knob.
If control knob does not
pop up when released, contact a
qualified service person or gas
supplier for repairs.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric
switch, do not use any phone
in your building.
Immediately call your gas
supplier from a neighbor’s
phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas
supplier, call the fire
department.
C.
Use only your hand to push in
or turn the gas control knob.
Never
use tools. If the knob will not push
in or turn by hand, don’t try to repair
it , call a qualified service technician
or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if
any part has been under water.
Immediately call a qualified service Note: If pilot goes out,repeat steps 3
through 7.This heater has a safety
technician to inspect the appliance
interlock system. Wait one(1)
and to replace any part of the control
minute before lighting pilot again.
system and any gas control which
8. Turn control knob counter clockhas been under water.
wise
to desired seating
level. The main burner should
LIGHTING
INSTRUCTIONS
1.
2.
3.
STOP!
Read
the
safety
information on the side of heater.
Make sure equipment shutoff
valve is fully open.
Turn control knob clockwise
to the OFF position.
light. Set control knob to any
heat level between HI and
LO. (see Figure 22)
CAUTION: Do not try to adjust
heating levels by using the
equipment shutoff valve.
1 2
Figure 20 - Control Knob In The
OFF Position HR10TN
Figure 21 - Pilot
Figure 22 - Burner Partterns
THERMOSTAT CONTROL OPERATION
The thermostatic control used on this
model
differs
from
standard
thermostats. Standard thermostats
simply turn on and off the burner. The
thermostat used on this heater senses
the room temperature. At times the
room may exceed the set temperature.
If so,the burner will shut off. The burner
will cycle back on when room temperature drops below the set temperature.
The control knob can be set t o any
comfort level between HI and LO.
Note: The thermostat sensing bulb
measures the temperature of air near
the heater cabinet.This may not always
agree with room temperature
(depending on housing construction,
installation location, room size,
open air temperatres,etc.) Frequent
use of your heater will let you determine your own comfort levels.
TO TURN OFF
GAS TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2. Turn off all electric power to the
appliance if service is to
be performed.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise
to
the PILOT position.
OPERATING HEATER
Continued
MANUAL LIGHTING
PROCEDURE
1.
2.
3.
4.
5.
Remove lower front panel (see
Figure 7 page 7).
Follow steps 1 through 5 under
Lighting Instructions on page12.
With control knob pressed in,
strike match. Hold match to
pilot until pilot lights.
Keep control knob pressed in
for 30 seconds after lighting pilot.
After 30 seconds, release control
knob.Follow step 8 under Lighting
Instuctions on page 12.
Replace lower front panel.
BURNER FLAME PATTERN
Figure 25 shows a correct burner
flame pattern. Figure 26 shows an
incorrect burner flame pattern.
If burner flame pattern is incorect, as
shown in Figure 26
turn heater off(see To Turn Off Gas
to Appliance pages 11&12)
see Troubleshooting, pages 14
through 16)
INSPECTING BURNER
Check pilot flame pattern and
burner flame pattern often.
PILOT FLAME PATTERN
Figure 23 shows a correct pilot
flame pattern. Figure 24 shows an
incorrect pilot flame pattern. The
incorrect pilot flame is not touching
thermocouple. This will cause the
thermocouple to cool. When the
thermocouple cools, the heater will
shut down. If pilot flame pattern is
incorrect, as shown in Figure 24.
turn heater off (see To Turn Off
Gas to Appliance. pages 11,12
see Troubleshooting. pages 14
through 16.
Figure 25 - Correct Burner Flame
Pattern
Figure 26 - Incorrect Burner Flame
Pattern
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air, or a small, soft
bristled brush to clean.
CLEANING BURNER
PILOT AIR INLET HOLE
We recommend that you clean the
unit every 2,500 hours of operation
or every three months.
We also recommend that you keep
the burner tube and pilot assembly
clean and free of dust and dirt. To
clean these parts we recommend
using compressed air no greater
than 30 PSl. Your local computer
store, hardware store. or home center may carry compressed air in a
can. You can use a vacuum cleaner
in the blow position. If using compressed air in a can, please follow
the directions on the can. If you don’t
follow directions on the can, you
could damage the pilot assembly.
1. Shut off the unit, including the
pilot. Allow the unit to cool for
at least thirty minutes.
2. Inspect burner, and pilot for dust
and dirt.
3. Blow air through the ports/slots
and holes in the bumer.
Also clean the pilot assembly. A
yellow tip on the pilot flame indicates dust and dirt in the pilot
assembly. There is a small pilot air
inlet hole about two inches from
where the pilot flame comes out of
the pilot assembly (see Figure 27).
With the unit off , lightly blow air
through the air inlet hole. You may
blow through a drinking straw if
compressed air is not available.
CLEANING AND
MAINTENANCE
Figure 23 - Correct Pilot Flame
Pattern
WARNING: turn off heater
and let cool before cleaning.
Figure 24 - Incorrect Pilot Flame
Pattern
CAUTION: you must keep control
areas, burner, and circulating air
passageways of heater clean. Inspect these areas of heater before
each use. Have heater inspected
yearly by a qualified service person.
Heater may need more frequent
cleaning due to excessive lint from
carpeting, bedding material, pet hair,
etc.
Figure 27 - Pilot Air Inlet Hole
1 3
CABINET
Air Passageways
Use a vacuum cleaner or
pressurized air to clean.
Exterior
Use a soft cloth dampened with
a mild soap and water mixture.
Wipe the cabinet to remove dust.
TROUBLESHOOTING
Note :
All
troubleshooting
items are listed in order of
operation.
WARNING: Only a qualified
service person should service and
repair heater.
OBSERVED PROBLEM
POSSIBLE CAUSE
When ignitor button is pressed and 1. Ignitor electrode is positioned
control knob is pressed in and turned to
wrong.
the PILOT position, there is no spark 2. Ignitor electrode is broken.
at ODS/pilot.
3. Ignitor electrode is not connected
to ignitor cable.
4. Ignitor cable is pinched or wet.
5. Broken ignitor cable.
6. Bad piezo ignitor.
When ignitor button is pressed and
control knob is press in and turned to
the PILOT position, there is a spark
at ODS/pilot but no ignition.
1. Gas supply turned off or equipment
shutoff valve is closed.
2. Control knob not fully pressed in
while pressing ignitor button.
3. Air in gas lines when installed.
4. ODS/pilot is clogged.
5. Gas regulator setting is not correct.
6. Control knob not in PILOT position.
ODS/pilot lights but flame goes out 1. Control knob is not fully pressed in.
when control knob is released.
2. Control knob is not pressed in
long enough.
3. Equipment shutoff valve is not
fully open.
4. Thermocouple connection is
loose at control valve.
5 Pilot flame is not touching
thermocouple, This allows
thermocouple to cool, causing
pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/ pilot
6. Thermocouple damaged.
7. Control valve damaged.
1 4
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot. This can damage
ODS/pilot unit.
REMEDY
1. Replace ignitor.
2. Replace ignitor.
3. Reconnect ignitor cable.
4. Free ignitor cable if pinched by
any
metal or tubing. Keep
ignitor cable dry.
5. Replace ignitor cable.
6. Replace piezo ignitor.
1. Turn on gas supply of open
equipment shutoff valve.
2. Fully press in control knob
while pressing ignitor button.
3. Continue holding down control
knob. Repeat igniting operation
until air is removed.
4. Clean ODS/pilot (see Cleaning and
Maintenance, Page 13) or
replace ODS/pilot assembly.
5. Replace gas regulator.
6. Turn control knob to PILOT position.
1. Press in control knob fully.
2. After ODS/pilot lights, keep control
knob pressed in 30 seconds.
3. Fully open equipment shutoff valve.
4. Hand tighten until snug, then
tighten 1/4 turn more.
5. A) Contact local natural gas
company.
B) Clean ODS/pilot (see Cleaning
and Maintenance, Page 13) or
replace ODS/pilot assembly.
6. Replace thermocouple.
7. Replace control valve.
TROUBLESHOOTING
Continued
REMEDY
POSSIBLE CAUSE
OBSERVED PROBLEM
Burner(s)does not light after
ODS/pilot is lit.
1. Burner orifice is clogged.
2. Burner orifice diameter is too small.
3. Inlet gas pressure is too low.
1. Clean burner orifice (see Cleaning
and Maintenance, Page 13) or
replace burner orifice.
2. Replace burner orifice.
3. Contact local natural gas company.
Delayed ignition of burner(s).
1. Manifold pressure is too low.
2. Burner orifice is clogged.
1. Contact local natural gas company.
2. Clean burner (see Cleaning and
Maintenance, Page 13) or replace
burner orifice.
Burner backfiring during combustion.
1. Burner orifice is clogged or
damaged.
2. Burner is damaged.
3. Gas regulator is defective.
1. Clean burner orifice (see Cleaning
and Maintenance, Page 13) or
replace.
2. Replace burner.
3. Replace gas regulator.
1. Plaque damaged.
2. Inlet gas pressure is too low.
1. Replace burner.
2. Contact local natural gas company.
3. Control knob set between locked
positions.
3. Turn control knob until it locks at
desired setting.
1. Residues from manufacturing
processes.
1. Problem will stop after a few hours
of operation.
Heater produces clicking/ticking
noise just after burner is lit or
shut off.
1. Metal is expanding while heating
or contracting while cooling.
1. This is common with most
heaters. If noise is excessive,
contact qualified service person.
White powder residue forming within
burner box or on adjacent
walls or furniture.
1. When heated, the vapors from
furniture polish, wax, carpet
cleaners, etc. turn into white
powder residue.
1.
Burner plaque(s) does not glow.
Slight smoke or
initial operation.
odor
during
1 5
Turn heater off when using
furniture polish, wax, carpet
cleaner, or similar products.
TROUBLESHOOTING
Continued
WARNING: If you smell gas
Shut off gas supply.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or
textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
REMEDY
POSSIBLE CAUSE
OBSERVED PROBLEM
Heater produces unwanted odors.
Heater shuts off in use (ODS operates).
1. Heater is burning vapors from
paint, hair spray, glues, etc.
(See IMPORTANT statement
above).
2 . G a s l e a k . S e e Wa r n i n g
Statement at top of page.
1.
Ventilate room. Stop using odor
causing products while heater
is running.
2.
Locate and correct all leaks(see
Checking Gas Connections,
page 10).
1.
Not enough fresh air is available.
1.
2.
Low line pressure.
3. ODS/pilot is partially clogged.
Open window and/or door for
ventilation.
2. Contact
local
natural gas
company.
3. Clean ODS/pilot (see Cleaning
page 13).
2. Control valve is defective.
Locate and correct all leak s(see
Checking Gas Connections,
page 10).
2. Replace control valve.
Gas odor exists during combustion.
1.
Foreign matter between control
valve and burner.
2. Gas
leak.
See Warning
Statement at top of page.
1.
Moisture/condensation
windows.
1.
1.
Gas odor even when control knob is
in OFF position.
noticed
on
1. Gas leak. See Warning
Statement at top of page.
Not enough combustion/ventilation
air.
1 6
1.
Take apart gas tubing and
remove foreign matter.
2. Locate and correct all leaks
(see Checking Gas Connections,
page 10).
Refer to Air for Combustion and
Ventilation Requirements, page
4.
SPECIFICATIONS
Btu(available)
Gas Type
Ignition
Pressure Regulator setting
Inlet Gas Pressure* (inches of water)
Maximum
Minimum
Dimensions, Inches (HxWxD)
Heater
Carton
Weight (pounds)
Heater
Shipping
HR06MN
6,000
Natural Only
Piezo
6" W.C.
HR10MN
5,500/10,000
Natural Only
Piezo
6" W.C.
HR10TN
10,000
Natural Only
Piezo
6" W.C.
10.5"
7"
10.5"
7"
10.5"
7"
19×14-1/4×7
22×16-3/4×8-1/8
19×14-1/4×7
22×16-3/4×8-1/8
19×14-1/4×7
22×16-3/4×8-1/8
12
15
13
16
13
16
Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).
* For purposes of input adjustment.
REPLACEMENT PARTS
Note: Use only original replacement
parts. This will protect your warranty
coverage for parts replaced under
warranty.
PARTS UNDER WARRANTY
Contact authorized dealer from
whom you purchased this product.
If they are unable to supply original
replacement part(s), call the number on the front of this manual. When
contacting your dealer or HearthRite,
have ready:
your name
your address
model and serial numbers of
your heater
how heater was malfunctioning
type of gas used (propane/LP or
natural gas)
purchase date
warranty card
Usually, we will ask you to return the
defective part to the factory.
ACCESSORIES
Purchase these heater accessories from your local dealer. If they
can not supply these accessories,
contact HearthRite for information.
You can also write to the address
listed on the front of this manual.
FLOOR MOUNTING STAND
For locating heater on the floor away
from a wall. Complete installation
instructions provided with floor
mounting stand.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this
product. If they can’t supply original
replacement part(s), contact
HearthRite at (800)851-3153.
TECHNICAL SERVICE
You may have further questions
about installation, operation, or
troubleshooting. If so, contact
HearthRite at (800)851-3153.
A Division of Empire Comfort Systems,Inc.
918 Freeburg Avenue
Belleville,IL 62220
1 7
Phone : 618-233-7420 or 1-800-851-3153
Fax : 618-233-7097 or 1-800-443-8648
www.hearthrite.com
ILLUSTRATED PARTS
BREAKDOWN
HR06MN
1 8
PARTS LIST
This list contains replaceable parts for your heater. When ordering replacement
parts, follow the instructions listed under Replacement Parts on page17 of this
manual.
HR06MN
KEY
NO.
1
2
3
4
5
5-1
5-2
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
PART
NUMBER
DESCRIPTION
MB10008E
MB09003E
ML006-02E
MB19007
ND1206x600x9
ND0803-6
ND0807-B2
ML026-03
ML069-02
NV2020-12
ML073-01
ML029-01
MB40051
MB40052
MB40053
ML090-03
MB16002
NRV81FI-6
ML129-02
ML079-01
ML119-01
ML057-04
ML060-02
ML083-03
Cabinet Assembly
Lower Front Panel Assembly
Reflector Unit
Burner Assembly
ODS Pilot Assembly
Thermocouple
Ignitor Electrode
ODS Mounting Bracket
Self Tapping Screws
Control Valve
Ignitor Line
Control Valve Fixed Nut
Main Inlet Tube Assembly
ODS Gas Line Assembly
Burner Gas Line Assembly
Injector
Control Knob Assembly
Pressure Regulator
Regulator Mounting Bracket
Self Locking Screws
Pressure Tap
Grill Guard
Mounting Bracket
lgnitor Assembly
QTY
1
1
1
1
1
1
1
1
10
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
PARTS AVAILABLE NOT SHOWN
MB28001
ML070-31E
Assembly Hardware
CSA/AGA Label
1 9
1
1
ILLUSTRATED PARTS
BREAKDOWN
HR10MN
2 0
PARTS LIST
This list contains replaceable parts for your heater. When ordering replacement
parts, follow the instructions listed under Replacement Parts on page 17 of this
manual.
HR10MN
KEY
NO.
1
2
3
4
5
5-1
5-2
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
PART
NUMBER
DESCRIPTION
MB10008E
MB09003E
ML006-01E
MB19005
ND1206x600x9
ND0803-6
ND0807-B2
ML026-02
ML069-02
NV2020-13
ML073-01
ML029-01
MB40033
MB40034
MB40035
MB40036
ML090-03
MB16002
NRV81FI-6
ML129-02
ML079-01
ML119-01
ML057-04
ML060-02
ML083-03
Cabinet Assembly
Lower Front Panel Assembly
Reflector Unit
Burner Assembly
ODS pilot Assembly
Thermocouple
Ignitor Electrode
ODS Mounting Bracket
Self Tapping Screws
Control Valve
Ignitor line
Control Valve Fixed Nut
Main Inlet Tube Assembly
ODS Gas Line Assembly
Burner Gas Line Assembly A
Burner Gas Line Assembly B
Injector
Control Knob Assembly
Pressure Regulator
Regulator Mounting Bracket
Self Locking Screws
Pressure Tap
Grill Guard
Mounting Bracket
lgnitor Assembly
QTY
1
1
1
1
1
1
1
1
10
1
1
1
1
1
1
1
2
1
1
1
4
1
1
1
1
PARTS AVAILABLE NOT SHOWN
MB28001
ML070-01E
Assembly Hardware
CSA/AGA Label
2 1
1
1
ILLUSTRATED PARTS
BREAKDOWN
HR10TN
2 2
PART LIST
This list contains replaceable parts for your heater. When ordering replacement
parts, follow the instructions listed under Replacement Parts on page 17 of this
manual.
HR10TN
KEY
NO.
1
2
3
4
5
5-1
5-2
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
PART
NUMBER
MB10007E
MB09003E
ML006-01E
MB19005
ND1206x600x9
ND0803-6
ND0807-B2
ML026-02
ML069-02
845-4.8x60Z
SIT544-000
ML111-02
ML056-03
MB40037
MB40039
MB40038
MB40040
ML090-03
MB40041
NRV81FI-6
ML129-02
ML079-01
ML057-04
ML060-02
ML083-03
DESCRIPTION
Cabinet Assembly
Lower Front Panel Assembly
Reflector Unit
Burner Assembly
ODS Pilot Assembly
Thermocouple
Ignitor Electrode
ODS Mounting Bracket
Self Tapping Screws
Screws
Thermostat Valve Assembly
Thermostat Valve Base/Bracket
“T” Joint
Main Inlet Tube Assembly
ODS Gas Line Assembly
Main Outlet Tube Assembly
Burner Gas Line Assembly A
Injector
Burner Gas Line Assembly B
Pressure Regulator
Regulator Mounting Bracket
Self Locking Screws
Grill Guard
Mounting Bracket
lgnitor Assembly
QTY
1
1
1
1
1
1
1
1
10
1
1
1
1
1
1
1
1
2
1
1
1
4
1
1
1
PARTS AVAILABLE NOT SHOWN
MB28001
ML070-29E
Assembly Hardware
CSA/AGA Label
2 3
1
1
2 4

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement