Orion VCM-X E-BUS Controller Technical Guide
PDF
ஆவணம்
விளம்பரம்
விளம்பரம்
www.orioncontrols.com VCM-X E-BUS Component & System Wiring Technical Guide Use For VCM-X E-BUS Controller Code: SS1030 and later For VCM Wiring Information, See Component & System Wiring Technical Guide - Form: OR-VCMWIRE-TGD RS-485 COMMUNICATION LOOP. WIRE “R” TO “R”, “T” TO “T” “SHLD” TO “SHLD” RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC RELAY COMMON FAN www.aaon.com RELAY 2 RELAY 3 RELAY 4 RELAY 5 www.orioncontrols.com AAON No.: V07150 VCM-X MODULAR E-BUS CONTROLLER Orion No.:OE332-23E-VCMX-MOD-A AI1 = SPC (SPACE TEMPERATURE SENSOR) AI2 = SAT (SUPPLY AIR TEMPERATURE SENSOR) AI3 = RAT (RETURN AIR TEMPERATURE SENSOR) AI4 = OAT (OUTDOOR AIR TEMPERATURE SENSOR) AI5 = SUCTION PRESSURE SENSOR (FROM EXP. MODULE) AI7 = SPACE TEMPERATURE SENSOR SLIDE ADJUST OR VOLTAGE RESET SOURCE A01 = ECONOMIZER (2-10 VDC OUTPUT) A02 = SUPPLY FAN VFD (0-10 VDC OUTPUT) E-BUS CONNECTOR ANALOG INPUT JUMPER SETTINGS LED BLINK CODES LED NAME STATUS1 STATUS2 AI1 THERM 4-20mA 0-10V 0-5V AI2 THERM 4-20mA 0-10V 0-5V MODULE ALARM 4 2 THERM 4-20mA 0-10V 0-5V MECH COOL FAIL 1 3 AI3 AI4 THERM 4-20mA 0-10V 0-5V AI5 THERM 4-20mA 0-10V 0-5V THERM 4-20mA 0-10V 0-5V PUSH BUTTON OVR 1 5 AI7 ZONE OVR 2 5 OUTPUT FORCE ACTIVE 0 6 NORMAL OPERATION 0 SAT FAIL 1 OAT FAIL 2 2 SPC FAIL 3 2 MECH HEAT FAIL 2 3 FAN PROOF FAIL 3 3 DIRTY FILTER 4 3 EMERGENCY SHUTDOWN 5 3 LOW SAT 1 4 HIGH SAT 2 4 CONT. TEMP COOL FAIL 3 4 CONT. TEMP HEAT FAIL ANALOG INPUT JUMPER SETTINGS MUST BE SET AS SHOWN FOR PROPER OPERATION STATIC PRESSURE 1 2 WattMaster Label #LB102073-01-A Rev.: 1A 4 4 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED 2 IC EXPANSION 2 I C DIGITAL SENSOR Table of Contents SYSTEM OVERVIEW, INSTALLATION & COMMISSIONING ...............................................................5 Systems Overview .................................................................................................................................................. 6 System Installation .................................................................................................................................................. 8 Transformer Sizing & Cabling - Devices Without Modular Connectors ............................................................ 9 Transformer & Wire Sizing - Devices With Modular Connectors .................................................................... 10 System Commissioning ....................................................................................................................................... 20 SYSTEM CONFIGURATIONS ............................................................................................................21 Stand Alone System Wiring .................................................................................................................................. 22 Interconnected System Wiring .............................................................................................................................. 23 Networked Single Loop System With CommLink Only ......................................................................................... 24 Networked Single Loop System With MiniLink PD & Modular VAV/Zone Controllers ........................................... 25 Networked Single Loop System With MiniLink PD & Non-Modular VAV/Zone Controllers ................................... 26 Networked Single Loop System With CommLink, MiniLink PD & Modular VAV/Zone Controllers........................ 27 Networked Single Loop System With CommLink, MiniLink PD & Non-Modular VAV/Zone Controllers ................ 28 Networked Multiple Loop System Wiring With Modular VAV/Zone Controllers ..................................................... 29 Networked Multiple Loop System Wiring With Non-Modular VAV/Zone Controllers ............................................. 30 VCM-X E-BUS CONTROLLER WIRING .............................................................................................31 Main Controller Wiring .......................................................................................................................................... 32 Main Controller Addressing ................................................................................................................................... 33 Digital Room Sensor Wiring .................................................................................................................................. 34 Wall-Mounted CO2 Sensor Wiring ......................................................................................................................... 34 Duct-Mounted CO2 Sensor Wiring ........................................................................................................................ 35 Space Temperature Sensor Wiring ....................................................................................................................... 36 Remote Supply Air Reset Wiring ........................................................................................................................... 36 Supply Air, Return Air, and Outdoor Air Temperature Sensor Wiring .................................................................... 37 Economizer Damper Actuator Wiring .................................................................................................................... 38 Supply Fan VFD & Bypass Damper Actuator Wiring ............................................................................................ 39 VCM-X EXPANSION, 4 BINARY INPUT, & 12 RELAY EXPANSION MODULE WIRING .....................41 VCM-X Expansion Module Input Wiring................................................................................................................ 42 VCM-X Expansion Module Output Wiring ............................................................................................................. 43 Suction Pressure Transducer Without Digital Compressor Wiring........................................................................ 44 Suction Pressure Transducer With Digital Compressor Wiring ............................................................................. 45 Expansion Module Binary Input Wiring ................................................................................................................. 46 4 Binary Input Expansion Module Wiring .............................................................................................................. 47 Outdoor Air Humidity Sensor Wiring ..................................................................................................................... 48 WattMaster Controls Inc. 8500 NW River Park Drive · Parkville , MO 64152 Toll Free Phone: 866-918-1100 PH: (816) 505-1100 · FAX: (816) 505-1101 · E-mail: [email protected] Visit our web site at www.orioncontrols.com Form: OR-VCMXWIRE-TGD-01B Copyright June 2015 WattMaster Controls, Inc. AAON is a registered trademark of AAON, Inc., Tulsa, OK. WattMaster Controls, Inc. assumes no responsibility for errors, or omissions. This document is subject to change without notice. 2 VCM-X Component & Systems Wiring Table of Contents Indoor Wall Mounted Humidity Sensor Wiring ...................................................................................................... 49 Return Air Humidity Sensor Wiring ....................................................................................................................... 50 Title 24 Economizer Actuator Feedback Wiring .................................................................................................... 51 Building Pressure Sensor, Actuator & VFD Wiring................................................................................................ 52 Modulating Heating Wiring .................................................................................................................................... 53 Modulating Cooling Wiring .................................................................................................................................... 54 Return Air Bypass Wiring ...................................................................................................................................... 55 12 Relay Expansion Module Wiring ...................................................................................................................... 56 Airflow Monitoring Station Wiring .......................................................................................................................... 57 MODULAR & NON-MODULAR VAV/ZONE CONTROLLER DIAGRAMS ..............................................59 Modular VAV/Zone Controller Actuator Package Wiring ....................................................................................... 60 Non-Modular VAV/Zone Controller Actuator Package Wiring ............................................................................... 61 Expansion Module Wiring ..................................................................................................................................... 62 Slaved Zone Wiring ............................................................................................................................................... 68 COMMUNICATION DEVICES DIAGRAMS ........................................................................................69 System Manager SD Modular Cable Connections ............................................................................................... 70 System Manager SD Cable Pigtail - Wiring Detail ................................................................................................ 71 System Manager SD Networked Wiring ............................................................................................................... 72 Modular Service SD Tool Connections.................................................................................................................. 73 System Manager Touch Screen II to VCM-X E-BUS Controller Wiring................................................................. 74 System Manager Touch Screen II to VAV/Zone Controller Wiring ........................................................................ 75 CommLink 5 Connections & Wiring ...................................................................................................................... 76 IP Module Installation Instructions ........................................................................................................................ 77 On-Site Computer Connection .............................................................................................................................. 78 Remote Site Computer Connection ...................................................................................................................... 79 USB-Link 2 Connections & Wiring ........................................................................................................................ 80 MiniLink Polling Device Wiring Using Modular Connectors .................................................................................. 81 MiniLink Polling Device Wiring Using Wire Terminals ........................................................................................... 82 Power/Comm Board Wiring - When Used For Local Loop Devices...................................................................... 83 Power/Comm Board Wiring - When Used For Network Loop Devices ................................................................. 84 ADD-ON DEVICES DIAGRAMS .........................................................................................................85 Lighting Panel Wiring For Standard Lighting Contactors ...................................................................................... 86 GPC-X Controller Wiring ....................................................................................................................................... 87 GPC-X Controller - Address Switch Setting .......................................................................................................... 88 GPC-XP Controller Wiring..................................................................................................................................... 89 GPC-XP Controller Addressing & Baud Rate Setting ........................................................................................... 90 GPC-XP Controller On-Board CommLink 5 Setting .............................................................................................. 91 GBD-X Controller - CO2 Applications Wiring ......................................................................................................... 92 GBD-X Controller - Space Temp. Sensor Averaging Wiring ................................................................................. 94 GBD-X Controller Address Switch Setting ............................................................................................................ 96 VCM-X Component & Systems Wiring 3 Table of Contents MODULE WIRING & CONNECTIONS ...............................................................................................97 HP1C Module Wiring ............................................................................................................................................ 98 HP2C2 Module Wiring .......................................................................................................................................... 99 Full Digital Module Wiring ................................................................................................................................... 100 Dual Digital Module Wiring .................................................................................................................................. 101 MODGAS-X Controller Wiring - Single Modulating Valve - No Staging .............................................................. 102 MODGAS-X Controller Wiring - Two Modulating Staged Valves ........................................................................ 103 MODGAS-XWR Controller Wiring - Single Modulating Valve - No Staging ........................................................ 104 MODGAS-XWR Controller Wiring - Single Modulating Valve & 1 Fixed Stage................................................... 105 MODGAS-XWR Controller Wiring - Two Modulating Staged Valves .................................................................. 106 MHGRV-X Controller Wiring................................................................................................................................ 107 WSHP-X2 Controller Wiring - Single Circuit ....................................................................................................... 108 WSHP-X2 Controller Wiring - Dual Circuit .......................................................................................................... 109 PREHEAT-X Controller Wiring ............................................................................................................................ 110 MODGAS II Controller Wiring ..............................................................................................................................111 MHGRV II Controller Wiring ................................................................................................................................ 112 MHGRV III Controller Wiring ............................................................................................................................... 113 MISCELLANEOUS DIAGRAMS & TECHNICAL INFORMATION .......................................................115 Modular Room Sensor Wiring ............................................................................................................................. 116 EPROM Chip Locations ...................................................................................................................................... 117 EPROM Chip Installation Procedures ................................................................................................................. 120 Updating Modules with the Service Tool SD ....................................................................................................... 121 Temperature & Humidity Sensor Voltage-Resistance Tables .............................................................................. 123 Pressure Sensors Voltage-Resistance Tables .................................................................................................... 124 Suction Pressure Transducer Testing ................................................................................................................. 125 4 VCM-X Component & Systems Wiring Systems Overview System Overview, Installation & Commissioning VCM-X Component & System Wiring 5 Systems Overview System Types Overview The Orion system components can be configured into several types of systems. It is a good idea to become familiar with the different types of systems and their architecture by reading the information in this section and looking at the configuration diagrams in the System Configurations section of this manual. The information below is designed to help you understand how the system components integrate with each other and the available configuration options. System Types Interconnected This system consists of a group of VCM-X E-BUS Controllers interconnected with communication cable to allow programming from one central location. Broadcasting between controllers is not available. Programming and status monitoring are accomplished by one or more of the following methods. 1. 2. Four different system configurations are available depending on the type and number of controllers that you have on your system. 1. Stand Alone By using an operator interface. This can be a Modular System Manager, a System Manager TS II, a Modular Service Tool, or all 3 devices. A computer interface can also be used in conjunction with the other operator interfaces listed above, or by itself. This requires a CommLink 5 or USB-Link 2 and a personal computer with the Prism 2 computer front end software installed. (See Figure 3, page 22 for Connection Diagram) 2. Interconnected (See Figure 4, page 23 for Connection Diagram) 3. Networked Single Loop (See Figures 5-9, pages 24-28 for Connection Diagrams) 4. Networked Multiple Loop Networked Single Loop The Networked Single Loop system, as its name implies, consists of a single communications loop. This loop utilizes a network device to share information that is broadcast from one controller to all controllers on the loop. The system can consist of the following devices. 1. A series of VCM-X E-BUS Controllers that utilizes a network device to share information that is broadcast from one controller to all controllers on the loop. 2. A single VCM-X E-BUS Controller and a series of VAV/ Zone Controllers. These VAV/Zone Controllers can either be of the Modular type or Non-modular type. The Modular type use Power/Comm Boards and prefabricated cables and the Non-Modular type utilize terminals and 2 conductor twisted pair with shield wire. A network device is used to share information which is broadcast back and forth between all controllers on the loop. (See Figures 10-11, pages 29-30 for Connection Diagrams) 5. Computer, CommLink 5, IP Module, USB-Link 2 (See Figures 54-58, pages 76-80 for Connection Diagrams) System Type Definitions Stand Alone This system consists of a single VCM-X E-BUS Controller. Programming and status monitoring are accomplished by one or more of the following methods. 1. 2. By using an operator interface. This can be a Modular System Manager, a System Manager TS II, a Modular Service Tool, or all 3 devices. A computer interface can also be used in conjunction with the other operator interfaces listed above, or by itself. This requires a CommLink 5 or USB-Link 2 and a personal computer with the Prism 2 computer front end software installed. These systems require a network device in the form of either a CommLink 5 communications interface or a MiniLink Polling Device. Both network devices may also be used together. Programming and status monitoring are accomplished by the following methods: 1. 2. By using an operator interface. This can be a Modular System Manager, a System Manager TS II, a Modular Service Tool, or all 3 devices. A computer interface can also be used in conjunction with the other operator interfaces listed above, or by itself. This requires a CommLink 5 or USB-Link 2 and a personal computer with the Prism 2 computer front end software installed. When using the MiniLink Polling Device alone, only the System Manager, System Manager TS II, and Modular Service Tool can be used to program and monitor the system. With the addition of the CommLink 5, the Prism 2 computer front end software and a PC can be used to program and monitor the system in addition to the Modular Service Tool, Modular System Manager, and the System Manager TS II. 6 VCM-X Component & System Wiring Systems Overview Communication Devices Networked Multiple Loop The Networked Multiple Loop System consists of two or more loops, each being called a “Local Loop”, with one “Network Loop” that ties the “Local Loops” together. Each of these loops can consist of one of the following groups of controllers: 1. A series of VCM-X E-BUS Controllers. 2. A single VCM-X E-BUS Controller and a series of VAV/ Zone Controllers. These VAV/Zone Controllers can either be of the Modular type or Non-modular type. The Modular type use Power/Comm Boards and prefabricated cables and the Non-Modular type utilize terminals and 2 conductor twisted pair with shield wire. A network device is used to share information which is broadcast back and forth between all controllers on the loop. To form the Networked Multiple Loop System, the following network devices are required: 1. 2. A MiniLink Polling Device is required per loop (Local Loop). This allows the controllers to share information that is broadcast from one controller to all controllers on that local loop. One CommLink 5 is required for the entire system. It resides on the Network Loop and allows for communications between all the local loops and provides for global broadcasts to all controllers on the entire system. Programming and status monitoring are accomplished by one or more of the following methods: 1. 2. By using an operator interface. This can be a Modular System Manager, a System Manager TS II, a Modular Service Tool, or all 3 devices. The Modular System Manager, System Manager TS II, or Modular Service Tool connect to any “Local Loop” on the system. A computer interface can also be used in conjunction with the other operator interfaces listed above, or by itself. This requires a personal computer with the Prism II computer front end software installed connected to the CommLink 5. Network Communications Devices MiniLink Polling Device The MiniLink Polling device is used in the following applications: 1. This device is required on all Zoning applications. It is optional on single loop VAV systems. 2. This device is required on each local loop of all Networked Multiple Loop systems. 3. This device is responsible for local loop broadcasts only. It always resides on the local loop. VCM-X Component & System Wiring For a Networked Single Loop VCM-X E-BUS system, this device can be used for tenant logging and alarm reporting to a Modular System Manager or System Manager TS II. It can be used to broadcast information such as outside air temperature or outside air humidity to all devices on the local loop. It can also be used to broadcast space temperature from a GPC-X or GPC-XP Controller to any controllers on this loop that do not have their own Space Temperature Sensor. For a Networked Single Loop VAV system, the MiniLink Polling Device can be used for tenant logging and alarm reporting to a Modular System Manager or System Manager TS II. It must be used to broadcast information such as, internal schedule, supply air temperature, fan and heat status, unoccupied calls for heating and cooling from the VAV/Zone Controllers, and forced modes of operation. For a Networked Single Loop Zoning system, this device must be used for zone voting, because it calculates the heating and cooling totals on the loop and broadcasts cooling, venting, and heating modes to the VCM-X E-BUS Controller. It can also be used for tenant logging and alarm reporting to the Modular System Manager or System Manager TS II. CommLink 5 The CommLink 5 device is used in the following applications. 1. A CommLink 5 is required on all Networked Multiple Loop Systems. 2. A CommLink 5 is optional on all Networked Single Loop Systems. 3. A CommLink 5 is required on any system when a permanent computer interface is desired. The USB-Link 2 can be used for temporary computer connection for setting up or servicing the system, but does not have the complete functionality that the CommLink 5 provides. The CommLink 5 is responsible for local loop broadcasts on a Networked Single Loop system, and on this type of system, the Loop switch on the back of the CommLink must be set to “Single.” This device is responsible for network broadcasts on Networked Multiple Loop systems. On this type of system, the Loop switch on the back of the CommLink must be set to “Multiple.” For a Networked Single Loop VCM-X E-BUS system, this device can be used for tenant logging and alarm reporting to a Modular System Manager or System Manager TS II. It can also be used to broadcast information like outside air temperature or outside air humidity to all local loops on the entire networked system. It may also be used to broadcast space temperature from a GPC-X or GPC-XP Controller to any controllers on the local loop that do not contain their own Space Temperature Sensor. On a Networked Single Loop VAV/Zone system, the CommLink 5 can be used to broadcast information such as internal schedule, supply air temperature, fan and heat status, unoccupied calls for heating and cooling, and forced modes of operation to and from the VAV/Zone Controllers. 7 System Installation Wiring Considerations Wiring Considerations Power/Comm Board Requirements Before beginning installation, please study the wiring diagrams for the controllers you are using with your particular application. These diagrams appear in this manual and can also be found in the technical guides supplied with your specific controllers. Wire and transformer sizing instructions and examples are found in Figures 1 & 2, pages 9-10 of this manual. Standard Connection Configurations and Use The Modular VAV/Zone Controllers are equipped with modular connections. Non-Modular VAV/Zone Controllers have wiring terminals instead of modular connectors. The VCM-X E-BUS Controller is supplied with modular connectors. The Power/Comm board is supplied with both terminals and a modular connector on the input side. All of its outputs use modular connectors. The Minlink Polling Device is equipped with both modular and wiring terminal blocks. We recommend (when possible) using modular cables instead of hard wiring to wire terminal blocks to save installation time and eliminate wiring errors. In some cases, however, hard wiring is unavoidable. The table below lists the various Orion devices/controllers and their available termination type(s) for communications and power wiring. Communications And Power Wiring Terminations For Orion Products Available Power And Communications Connections Orion Controller Or Device VCM-X E-BUS Modular Connectors Only Wire Terminals Only Both Modular Connectors And Wire Terminals X VAV/Zone • X Power/Comm Board X MiniLink PD X CommLink 5 *Modular System Manager X X GPC-X X Lighting Controller The Power/Comm board must always be powered by its own dedicated 24 VAC transformer connected to its 2-wire, 24 VAC input terminals (TB1). Local Loop communications can be transferred to the Power/Comm Board via a modular cable connected to its “Comm In” modular connector input terminal (P2). This modular cable connection can originate from the “Local Loop” modular connector of the MiniLink PD for this loop, another Power/Comm board output on the same loop, or a Modular VAV/Zone Controller or Modular System Manager output on the same loop. A Power/Comm board can also be connected if desired to the “Local Loop” by hard wiring a 2-wire shielded cable connected between its 3-wire communications input terminal (TB1) and a Power/Comm board, or the MiniLink PD “Local Loop”, 3-wire communications terminal. For detailed wiring diagrams, see the Power/Comm board wiring diagrams in the “Communication Devices Diagrams” section of this manual. For Power/Comm board transformer sizing, see Figures 1 & 2, pages 9-10 of this manual. Alternative Connection Configuration and Use If desired, the Power/Comm board can also be used to transfer both 24 VAC power and “Network Loop” communications to multiple MiniLink PDs. Connection between the MiniLink PD(s) and Power/ Comm board(s) is accomplished by using modular cables between the Power/Comm board’s modular output connectors and the MiniLink PD(s)’s “Network Loop” modular input connectors. When a Power/Comm board is used to connect power and communications to MiniLink PDs in this manner, that particular Power/Comm board cannot also be used to share communications and/or power with Modular VAV/Zone Controllers or Modular System Manager(s). X System Manager TS II GPC-XP Power/Comm boards are typically used on Networked, Single, and Multiple Loop systems to transfer 24 VAC power and “Local Loop” communications to Modular VAV/Zone Controllers, Modular System Managers, or other Power/Comm boards. X X * The System Manager is supplied with a pigtail connector that has a modular plug on one end and stripped wires on the other end. The pigtail is used to allow wiring connection to the HVAC unit controller wire terminals and to a 24 VAC power transformer on systems that do not use Power/ Comm boards. Warning: Do not ground the 24 VAC transformer that is to be used with the Power/Comm board. Grounding of the transformer will damage the Power/Comm board and all boards connected to it. A separate transformer must be used for each Power/Comm board. No exceptions. Do not connect any other devices to the transformer used for the Power/Comm board! For detailed wiring diagrams, see the Power/Comm board wiring diagrams in the “Communication Devices Diagrams” section of this manual. For Power/Comm board transformer sizing, see Figures 1 & 2, pages 9-10 of this manual. Table 1: Communications and Power Terminations 8 VCM-X Component & Systems Wiring System Installation Transformer Sizing & Wiring For Devices W/Out Modular Connectors 24 VAC Power - Transformer & Wire Sizing Considerations for Devices Without Modular Connectors Some installers like to use one large 24 VAC transformer to power several devices. This is allowable as long as polarity is maintained to each device on the transformer circuit. Warning: If polarity is not maintained, severe damage to the devices may result. WattMaster Controls recommends using a separate transformer for each device in order to eliminate the potential for damaging controllers due to incorrect polarity. Using separate transformers also allows redundancy in case of a transformer failure. Instead of having 8 controllers inoperative because of a malfunctioning transformer you have only 1 controller off line. If the installer does decide to use a large transformer to supply power to several devices, the following transformer and wire sizing information is presented to help the installer correctly supply 24 VAC power to the devices. Following is a typical example to help the installer to correctly evaluate transformer and wiring designs. Each GPC-XP Controller requires 8 VA @ 24VAC power. In the examples below we have a total of 8 GPC-XP Controllers. 8 GPC-XP Controllers @ 8 VA each................ 8 x 8 VA = 64 VA. The above calculation determines that our transformer will need to be sized for a minimum of 64 VA if we are to use one transformer to power all the controllers. Next we must determine the maximum length of run allowable for the wire gauge we wish to use in the installation. Each wire gauge below has a voltage drop per foot value we use to calculate total voltage drop. 18ga wire.................................0.00054 = voltage drop per 1’ length of wire 16ga wire.................................0.00034 = voltage drop per 1’ length of wire 14ga wire.................................0.00021 = voltage drop per 1’ length of wire For our example we will use 18 gauge wire. WattMaster recommends 18 gauge as a minimum wire size for all power wiring. Next use the voltage drop per foot value for 18 gauge wire from the list above and multiply by the total VA load of the 8 controllers to be installed. 0.00054 (Voltage drop per foot for 18 gauge wire) x 64VA controller load = 0.0346 Volts/Ft. WattMaster controllers will operate efficiently with a voltage drop no greater than 2 Volts. Divide the total allowable voltage drop of 2 Volts by the number you arrived at above and you have the maximum number of feet you can run the 18 gauge wire with an 75 VA transformer with no more than a 2 Volt drop at the farthest controller from the transformer.. 2 (Volts total allowable voltage drop) = 57.80 feet 0.0346 (Voltage drop per 1 ft. @ 64VA load) Parallel circuiting of the wiring instead of wiring all 8 controllers in series allows for longer wire runs to be used with the same size wire (as shown in our examples below). It is often necessary for the installer to calculate and weigh the cost and installation advantages and disadvantages of wire size, transformer size, multiple transformers, circuiting, etc., when laying out an installation. No matter what layout scheme is decided upon, it is mandatory that the farthest controller on the circuit is supplied with a minimum of 22 Volts. B B C B C D E A 120 / 24VAC A 120 / 24VAC A Distance A to B cannot exceed 57.80 Ft. Distance from A Distance from A Distance from A Distance from A 120 / 24VAC Distance from A to B cannot exceed 115.60 Ft. Distance from A to C cannot exceed 115.60 Ft. JOB NAME Component Power Requirements VCM-X E-BUS Controller ................8 VA VAV/Zone Controller.........................6 VA GPC-X Controller ............................8 VA GPC-XP Controller ..........................8 VA Lighting Panel Controller .....10 VA MiniLink Polling Device..........6 VA to B cannot exceed 230.40 Ft. to C cannot exceed 230.40 Ft. to D cannot exceed 230.40 Ft. to E cannot exceed 230.40 Ft. FILENAME O-VCMXWRSIZ1A.CDR DATE: 01/07/13 PAGE 1 of 2 DESCRIPTION: Orion VCM-X System Wire & Transformer Sizing Figure 1: Transformer & Wire Sizing - Devices without Modular Connectors VCM-X Component & Systems Wiring 9 System Installation Transformer Sizing & Cabling For Devices With Modular Connectors 24VAC Power - Transformer & Cabling Considerations for Devices With Modular Connectors Modular devices include the VAV/Zone Controller, Modular System Manager & MiniLink Polling Device. When sizing transformers for the devices it is important to design your layout so that the fewest number of Power/Comm distribution boards and the least number of transformers can be used. The polarity problem discussed in regards to other devices that do not have modular connections is not an issue with the modular devices as they cannot be connected with reversed polarity because of the modular board connectors and cable. Also the prefabricated cable is always 16 gauge. Wire size selection is therefore not an issue with the modular devices. However, the same minimum voltage rules apply to modular devices as with other non-modular devices. In order to simplify wiring design and layout with modular devices the following rules apply: Power/Comm Board maximum transformer size = 100VA. This is due to the board circuitry and fusing. Each modular device is to be calculated at 6VA. This allows for a maximum of 16 devices per Power/Commboard. If more than 16 devices are required, multiple Power/Comm boards must be used. No more than 6 modular devices allowed per branch circuit. (The Power/Comm board has a total of 4 branch circuits) The longest total run per branch circuit is 240 Ft. This is due to voltage drop on the prefabricated cable. Below are some examples of transformer sizing and branch circuit design. 6 Devices Maximum Per Branch Circuit 13 Devices At 6 VA = 78 VA Use 80 VA Transformer 16 Devices At 6 VA = 96 VA Use 100 VA Transformer Power/Comm Board Power/Comm Board 120 / 24VAC 100 VA Transformer Minimum See Warning Note Below 120 / 24VAC 80 VA Transformer Minimum See Warning Note Below A A Total length of all modular cables used on each branch ( A to B) cannot exceed 240 Ft. 6 Devices Maximum Per Branch Circuit 12 Devices At 6 VA = 72 VA Use 75 VA Transformer 6 Devices At 6 VA = 36 VA Use 40 VA Transformer Power/Comm Board Power/Comm Board 120 / 24VAC 75 VA Transformer Minimum See Warning Note Below A 120 / 24VAC 40 VA Transformer Minimum See Warning Note Below A Total length of all modular cables used on each branch ( A to B) cannot exceed 240 Ft. JOB NAME WARNING! DO NOT GROUND THE 24V TRANSFORMER THAT IS TO BE USED WITH THE POWER/COMM BOARDS. GROUNDING OF THE TRANSFORMER WILL DAMAGE THE POWER/COMM BOARD AND ALL BOARDS CONNECTED TO IT. A SEPARATE TRANSFORMER MUST BE USED FOR EACH POWER/COMMBOARD. NO EXCEPTIONS. DO NOT CONNECT ANY OTHER DEVICES TO THE TRANSFORMER USED FOR THE POWER/COMM BOARD! FILENAME O-VCMXWRSIZ1A.CDR DATE: 03/09/06 PAGE 2 of 2 DRAWN BY: B. CREWS DESCRIPTION: Orion VCM-X System Wire & Transformer Sizing Figure 2: Transformer & Wire Sizing - Devices with Modular Connectors 10 VCM-X Component & Systems Wiring System Installation Stand-Alone MiniLink Polling Device (MiniLink PD) 2. The Modular Service Tool SD connects to the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Stand Alone. 3. The Modular System Manager SD comes supplied with a 12 foot modular cable with a modular connector on one end and stripped wires on the other. If the Modular System Manager is to be mounted in a remote location, run 18 gauge, 2 conductor shielded cable for communications from the controller’s 3 wire communications terminal to a junction box. Run 18 gauge minimum, 2-wire, power wires from a separate 24 VAC, 6 VA minimum transformer into the junction box. Splice the modular cable to the communications and power wire inside of the junction box by making solid connections, using wire nuts or butt splice connectors. The Communications setting must be set to Lo Speed Stand Alone. 4. The System Manager TS II utilizes a 3-wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. A separate transformer is required for the System Manager TS II. It has a 2-wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using using 18 gauge minimum 2 conductor wire. In the Settings Menu, enter <0> for the System Manager Address. 5. If a CommLink 5 is used for a computer interface, connect communications using 18 gauge, 2 conductor with shield cable. Connect from the controller’s 3-wire communications connector to the CommLink’s 3-wire communications connector. For this type of system, the Loop switch located on the back of the CommLink 5 must be set to “Single”. 6. Use 18 gauge minimum, 2-wire cable for all 24 VAC power wiring. Be sure to maintain polarity on all boards. If a CommLink is connected, use the 110 VAC/24 VAC power supply furnished with the CommLink for its power source. 7. Before powering up the controller, set the desired board address on the controller (usually 1). Standard Connection Configurations and Use The MiniLink PD is used on Networked Single and Multiple Loop systems to provide two-way communication between all devices on it’s “Local Loop” and to all the other “Network Loop” devices on the entire system. The MiniLink PD is equipped with both modular connectors and hard wiring terminal blocks for connection of 24 VAC power “Local Loop” and “Network Loop” communications. Each MiniLink PD is normally hard wired to a 24 VAC power source connected to its 24 VAC input terminal (TB1). “Network Loop” communications are transferred between multiple MiniLink PDs by modular cables connected to their “Network Loop” modular connectors (P3 and P5). A CommLink 5 must be connected to one of the MiniLink PDs on the system by using a 2-wire shielded cable connected between its 3-wire “Network Loop” communications terminal block (TB4) and to the CommLink’s “485 Loop” terminal block. Transfer of “Local Loop” communication from the MiniLink PD to a Power/Comm board is made by using a modular cable connected between the MiniLink PD “Local Loop” modular connector (P4) and the Power/Comm board modular “Comm In” connector (P2). If desired as an alternative, transfer of “Local Loop” communication from the MiniLink PD to a Power/Comm board can be made by hard wiring a 2-wire shielded cable connected between the MiniLink PD’s 3-wire communications terminal (TB1) and the 3-wire communications input (TB1) on the Power/Comm board. Installation Procedures The installation procedures that follow are based on recommended methods of wiring connection and controller installation. Installation procedures vary depending on the type of system you are installing. The system you are installing could be a Stand Alone, Interconnected, Networked Single Loop, or Networked Multiple Loop system. The Networked System also has installation variations based on the type of components you are installing for that system. The following information explains the procedures for all of these systems. Please find the system and components that closely match your system and follow the outlined procedures. Stand Alone Systems See Figure 3, page 22 of this manual for a detailed Stand Alone System wiring diagram. Also see pages 9-10 for wire and transformer sizing information. You should review these diagrams before attempting connections or powering up the controller or interface devices. 1. Install a 24 VAC, 8 VA minimum, transformer for the VCM-X E-BUS Controller and wire from transformer to the controller using 18 gauge minimum, 2 conductor cable for power. Observe polarity on all power wiring. VCM-X Component & Systems Wiring 11 System Installation Interconnected & Networked Single Loop Interconnected Systems 6. Use 18 gauge minimum, 2-wire cable for all 24 VAC power wiring. Be sure to maintain polarity on all boards. If a CommLink 5 is installed, use the 110 VAC/24 VAC power supply furnished with the CommLink for its power source. 7. Before powering up the controllers, set each controller’s board address to a unique number from 1 through 60. See Figure 4, page 23 for a detailed Interconnected System wiring diagram. Also see pages 9-10 for wire and transformer sizing information. You should review these diagrams before attempting connections or powering up the controller or interface devices. 1. 2. 3. 4. 5. 12 Connect all VCM-X E-BUS Controllers in a daisy chain format using 18 gauge, 2 conductor shielded cable for communications. Install a separate 24 VAC, 8 VA minimum transformer for each VCM-X E-BUS Controller and wire the transformers to each controller using 18 gauge minimum, 2 conductor cable. Observe polarity on all boards. The Modular Service Tool SD will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Stand Alone. The Modular System Manager SD comes supplied with a 12 foot modular cable with a modular connector on one end and stripped wires on the other. If the Modular System Manager is to be mounted in a remote location, run 18 gauge, 2 conductor shielded cable for communications from the controller’s 3-wire communications terminal to a junction box. Run 18 gauge minimum, 2-wire power wires from a separate 24 VAC, 6 VA minimum transformer into the junction box. Splice the modular cable to the communications and power wire inside of the junction box by making solid connections, using wire nuts or butt splice connectors. The Communications setting must be set to Lo Speed Stand Alone. . The System Manager TS II utilizes a 3-wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. A separate transformer is required for the System Manager TS II. It has a 2-wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using 18 gauge minimum 2 conductor wire. In the Settings Menu, enter <0> for the System Manager Address and make sure One to One Unit Connection is not selected. If a CommLink 5 is used to provide for connection to a computer interface, connect communications using 18 gauge, 2 conductor shielded cable. Connect from one of the controller’s 3-wire communications connectors to the CommLink’s 3-wire communications connector. For this type of system, the Loop switch on the back of the CommLink needs to be set to “Single”. Networked Single Loop Systems See Figures 5-9, pages 24-28 for detailed Networked Single Loop System wiring diagrams. Also see pages 9-10 for wire and transformer sizing information. You should review these diagrams before attempting connections or powering up the controller or interface devices. Loop Containing VCM-X E-BUS Controllers Only (Using CommLink 5) 1. Connect all VCM-X E-BUS Controllers on the loop in a daisy chain format using 18 gauge, 2 conductor shielded cable wiring from each controller’s communication terminals to the next controller’s communication terminals. Install a separate 24 VAC, 8 VA minimum transformer for each controller and wire from controllers to the transformers using 18 gauge minimum, 2 wire cable. Be sure to observe polarity on all boards. 2. Connect 18 gauge minimum 2 conductor shielded cable from one of the VCM-X E-BUS Controller’s 3 wire communication terminals to the CommLink5’s 3 wire communications terminal. The Loop switch on the back of the CommLink must be set to “Single” for this installation. Use the 110 VAC/24 VAC power supply furnished with the CommLink for its power source. 3. The Modular Service Tool SD will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. 4. The Modular System Manager SD comes supplied with a 12 foot long modular cable with a modular connector on one end and stripped wires on the other. If the System Manager is to be mounted in a remote location, run 18 gauge, 2 conductor shielded cable for communications from one of the controller’s 3 wire communications terminals to a junction box. Run 18 gauge, 2 wire, 24 VAC power wires supplied by a separate transformer into the junction box. Splice modular cable to the communications and power wire inside of the junction box using solid connections from wire nuts or buttsplice connectors. The Modular System Manager MUST always be connected on the “Local Loop”, never the “Network Loop”. The Communications setting must be set to Lo Speed Network Mode. VCM-X Component & Systems Wiring System Installation Networked Single Loop 5. 6. The System Manager TS II utilizes a 3 wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. A separate transformer is required for the System Manager TS II. It has a 2 wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using 18 gauge minimum, 2 conductor wire. In the Settings Menu, enter <63> for the System Manager Address. 6. The Modular System Manager SD can connect to any VAV/Zone Controller or directly to one of the Power/ Comm board’s modular output connectors. The Communications setting must be set to Lo Speed Network Mode. 7. The System Manager TS II utilizes a 3 wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. Since you are using Modular VAV/Zone Controllers, you can use a modular pigtail connector that has a modular connector on one end and stripped wires on the other to connect the System Manager TS II to the Power/Comm board or one of the Modular VAV/Zone Controllers. A separate transformer is required for the System Manager TS II. It has a 2 wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using 18 gauge minimum wire. In the Settings Menu, enter <63> for the System Manager Address. 8. Before powering up the controllers, set each VAV/ Zone Controller’s board address to a unique number from 1 through 58. Address the VCM-X E-BUS Controller at 59. Set MiniLink PD’s address at 1. Before powering up the controllers, set each controller’s board address to a unique number from 1 through 59. Loop Containing VCM-X E-BUS Controller with Modular VAV/Zone Controllers and MiniLink PD Only 1. Connect all controllers in a daisy chain format using 18 gauge, 2 conductor shielded cable for communications. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 8 VA minimum, transformer for the VCM-X E-BUS Controller and wire from the transformer to the VCM-X E-BUS Controller. Using 18 gauge minimum, 2 wire cable for power, install a separate 24 VAC transformer sized for the required VA load for each Power/Comm board on the loop and wire from each transformer to its Power/ Comm board. Observe polarity on all boards. 2. Connect 2 conductor shielded cable from the VCM-X E-BUS Controller’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Local Loop”. Use 18 gauge minimum, 2 wire cable for all power wiring and be sure to maintain polarity on all boards. 3. Using a modular cable, connect from the MiniLink PD’s modular connector marked “Local Loop” to a Power/Comm board’s modular input connector. 4. Using modular cables, connect from the Power/Comm board’s modular output connectors to the Modular VAV/ Zone Controllers. The VAV/Zone Controllers connect together using modular cables from each VAV/Zone Controller to the next controller and/or to a Power/ Comm board. A maximum of 16 VAV/Zone Controllers are allowed per Power/Comm board. If you have more than 16 VAV/Zone Controllers, you will need multiple Power/Comm boards. Each Power/Comm board must have its own 24 VAC transformer sized for the total number of VAV/Zone Controllers connected to it. 5. The Modular Service Tool SD will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. VCM-X Component & Systems Wiring Note: Only communications, not power, are transferred from the MiniLink Polling Device to the Power/ Comm board via the modular cable. A separate transformer is required for the MiniLink Polling Device. Both power and communications are transferred from the Power/Comm board to the VAV/Zone Controllers and the Modular System Manager. Warning: Each Power/Comm board must have its own 24 VAC transformer for its power source. This transformer cannot be shared with any other board. Do not ground the transformer that is connected to the Power/Comm board. The transformer should be sized for the required VA by using the information found on pages 9-10 of this manual. 13 System Installation Networked Single Loop Loop Containing VCM-X E-BUS Controller with Non-Modular VAV/Zone Controllers and MiniLink PD Only 1. 2. 3. 14 Connect 2 conductor shielded cable from the VCM-X E-BUS Controller’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Local Loop”. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 8 VA minimum, transformer for the VCM-X E-BUS Controller and wire from the transformer to the VCM-X E-BUS Controller. Also connect a 24 VAC 6 VA minimum transformer to the MiniLink PD power terminals using 18 gauge minimum, 2 wire cable. Then wire from the VCM-X E-BUS Controller’s 3 wire communications connector or the MiniLink PD’s 3 wire communications connector marked ”Local Loop” to the first VAV/Zone Controller’s 3 wire communications terminals. Using 18 gauge minimum, 2 wire cable, connect all of the associated Non-Modular VAV/Zone Controllers in a daisy chain format using 18 gauge, 2 conductor shielded cable for communications. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 6 VA minimum, transformer for each Non-Modular VAV/Zone Controller and wire from each transformer to its VAV/Zone Controller. WattMaster recommends you use a separate transformer for each VAV/Zone Controller as stated. As an alternative, it is allowable to have several NonModular VAV/Zone Controllers share one properly sized transformer (6 VA per VAV/Zone Controller). Warning: Polarity must be observed on all of the VAV/Zone Controllers or damage to the controllers will result. Use 18 gauge minimum, 2 wire cable for all power wiring and be sure to maintain polarity on all boards. The Modular System Manager can connect to any VAV/ Zone Controller or to the VCM-X E-BUS Controller. Use the supplied pigtail cable which has a modular connector for connection to the back of the Modular System Manager and wire to any controller on the communications local loop with communication wire terminals. A separate transformer is required for the Modular System Manager. Connect the 2 power wires from the pigtail connector to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power. The Communications setting must be set to Lo Speed Network Mode. 4. The System Manager TS II utilizes a 3 wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. A separate transformer is required for the System Manager TS II. It has a 2 wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using 18 gauge minimum wire. In the Settings Menu, enter <63> for the System Manager Address. 5. Before powering up the controllers, set each VAV/ Zone Controller’s board address to a unique number from 1 through 58. Address the VCM-X E-BUS Controller at 59. Set MiniLink PD’s address at 1. Loop Containing VCM-X E-BUS Controller with Modular VAV/Zone Controllers and CommLink 5 Only 1. Connect all controllers in a daisy chain format using 18 gauge, 2 conductor shielded cable for communications. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 8 VA minimum, transformer for the VCM-X E-BUS Controller and wire from transformer to the VCM-X E-BUS Controller. Using 18 gauge minimum, 2 wire cable for power, install a separate 24 VAC, transformer sized for the required VA load for each Power/Comm board on the loop and wire from each transformer to its Power/ Comm board. Observe polarity on all boards. 2. Use 18 gauge minimum, 2 wire cable for all 24 VAC power wiring. Be sure to maintain polarity on all boards. Use the 110 VAC/24 VAC power supply furnished with the CommLink for its power source. 3. Using 2 conductor shielded cable, connect from the CommLink 5’s 3 wire communications connector to the Power/Comm board’s or VCM-X E-BUS Controller’s 3 wire communications input connector. The Loop switch on the back of the CommLink 5 should be set to “Single”. 4. Using modular cables, connect from the Power/Comm board’s modular output connectors to the VAV/ Zone Controllers. The VAV/Zone Controllers connect together using modular cables from each VAV/Zone Controller to the next controller and/or to a Power/ Comm board. A maximum of 16 VAV/Zone Controllers are allowed per Power/Comm board. If you have more than 16 VAV/Zone Controllers, you will need multiple Power/Comm boards. Each Power/Comm board must have its own 24 VAC transformer sized for the total number of VAV/Zone Controllers connected to it. 5. The Modular System Manager can connect to any VAV/ Zone Controller or directly to one of the Power/Comm board’s modular output connectors. The Communications setting must be set to Lo Speed Network Mode. The Modular Service Tool SD will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. VCM-X Component & Systems Wiring System Installation Networked Single Loop 6. The Modular Service Tool SD will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. 7. The System Manager TS II utilizes a 3 wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. A separate transformer is required for the System Manager TS II. It has a 2 wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using 18 gauge minimum wire. In the Settings Menu, enter <63> for the System Manager Address. 8. Before powering up the controllers, set each VAV/ Zone Controller’s board address to a unique number from 1 through 58. Address the VCM-X E-BUS Controller at 59. the first VAV/Zone Controller’s 3 wire communications terminal. Connect all of the associated Non-Modular VAV/Zone Controllers in a daisy chain format using 18 gauge, 2 conductor shielded cable for communications. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 6 VA minimum, transformer for each Non-Modular VAV/Zone Controller and wire from each transformer to its VAV/Zone Controller. WattMaster recommends you use a separate transformer for each VAV/Zone Controller as stated. As an alternative, it is allowable to have several Non-Modular VAV/Zone Controllers share one properly sized transformer (6 VA per VAV/Zone Controller). Warning: Polarity must be observed on all of the VAV/Zone Controllers or damage to the controllers will result. Use 18 gauge minimum, 2 wire cable for all 24 VAC power wiring. Be sure to maintain polarity on all boards. 3. The Modular System Manager can connect to any VAV/ Zone Controller or to the VCM-X E-BUS Controller. Use the supplied pigtail cable which has a modular connector for connection to the back of the Modular System Manager and wire to any controller on the communications local loop with communication wire terminals. A separate transformer is required for the Modular System Manager. Connect the 2 power wires from the pigtail connector to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power. The Communications setting must be set to Lo Speed Network Mode. 4. The Modular Service Tool SD will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. 5. The System Manager TS II utilizes a 3 wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. A separate transformer is required for the System Manager TS II. It has a 2 wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using using 18 gauge minimum wire. In the Settings Menu, enter <63> for the System Manager Address. 6. Before powering up the controllers, set each VAV/ Zone Controller’s board address to a unique number from 1 through 58. Address the VCM-X E-BUS Controller at 59. Note: Both power and communications are transferred from the Power/Comm board to the VAV/Zone Controllers and the Modular System Manager. Only communications are transferred from Power/Comm board to Power/Comm board. Warning: Each Power/Comm board must have its own 24 VAC transformer for its power source. This transformer cannot be shared with any other board. Do not ground the transformer that is connected to the Power/Comm board. The transformer should be sized for the required VA by using the information found on pages 9-10 of this manual. Loop Containing VCM-X E-BUS Controller with Non-Modular VAV/Zone Controllers and CommLink 5 Only 1. 2. Connect 2 conductor shielded cable from the VCM-X E-BUS Controller’s 3 wire communications connector to the CommLink 5’s 3 wire communications connector. Use the 110 VAC/24 VAC power supply furnished with the CommLink for its power source. Be sure to maintain polarity on all boards. The Loop switch on the back of the CommLink 5 should be set to “Single”. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 8 VA minimum, transformer for the VCM-X E-BUS Controller and wire from the transformer to the VCM-X E-BUS Controller. Then wire from the VCM-X E-BUS Controller’s 3 wire communications connector or the CommLink 5’s 3 wire communications connector to VCM-X Component & Systems Wiring 15 System Installation Networked Single Loop Loop Containing VCM-X E-BUS Controller with Modular VAV/ Zone Controllers, MiniLink PD, and CommLink 5 1. 2. 16 Connect the CommLink 5 to the MiniLink PD by using 2 conductor shielded cable to connect from the CommLink 5’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Network Loop”. Use the 110 VAC/24 VAC power supply furnished with the CommLink for its power source. Be sure to maintain polarity on all boards. The Loop switch on the back of the CommLink 5 should be set to “Multiple”. Also connect a 24 VAC 6 VA minimum transformer to the MiniLink PD power terminals using 18 gauge minimum, 2 wire cable. Connect all controllers in a daisy chain format using 18 gauge, 2 conductor shielded cable for communications. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 8 VA minimum, transformer for the VCM-X E-BUS Controller and wire from the transformer to the VCM-X E-BUS Controller. Using 18 gauge minimum, 2 wire cable for power, install a separate 24 VAC transformer sized for the required VA load for each Power/Comm Board on the loop and wire from each transformer to its Power/Comm board. Observe polarity on all boards. 3. Using 2 conductor shielded cable, connect from the VCM-X E-BUS Controller’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Local Loop”. Use 18 gauge minimum wire for power and observe polarity on all boards. 4. Using a modular cable, connect from the MiniLink PD’s modular connector marked “Local Loop” to a Power/Comm board’s modular input connector. 5. Using modular cables, connect from the Power/Comm board’s modular output connectors to the VAV/Zone Controllers. The VAV/Zone Controllers connect together using modular cables from each VAV/Zone Controller to the next controller and/or to a Power/Comm board. A maximum of 16 VAV/Zone Controllers are allowed per Power/Comm board. If you have more than 16 VAV/ Zone Controllers, you will need multiple Power/Comm boards. Each Power/Comm board must have its own 24 VAC transformer sized for the total number of VAV/ Zone Controllers connected to it. 6. The Modular System Manager can connect to any VAV/Zone Controller or directly to one of the Power/ Comm board’s modular output connectors. The Communications setting must be set to Lo Speed Network Mode. 7. The System Manager TS II utilizes a 3 wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. Since you are using Modular VAV/Zone Controllers, you can use a modular pigtail connector that has a modular connector on one end and stripped wires on the other to connect the System Manger TS II to the Power/Comm board or one of the Modular VAV/Zone Controllers. A separate transformer is required for the System Manager TS II. It has a 2 wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using 18 gauge minimum wire. In the Settings Menu, enter <63> for the System Manager Address. 8. The Modular Service Tool SD will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. 9. Before powering up the controllers, set each VAV/ Zone Controller’s board address to a unique number from 1 through 58. Address the VCM-X E-BUS Controller at 59. Set MiniLink PD’s address at 1. Note: Only communications, not power, is transferred from the MiniLink Polling Device to the Power/ Comm board via the modular cable. Both power and communications are transferred from the Power/ Comm board to the VAV/Zone Controllers and the Modular System Manager. Warning: Each Power/Comm board must have its own 24 VAC transformer for its power source. This transformer cannot be shared with any other board. Do not ground the transformer that is connected to the Power/Comm board. The transformer should be sized for the required VA by using the information found on pages 9-10 of this manual. Loop Containing VCM-X E-BUS Controller with Non-Modular VAV/Zone Controllers, MiniLink PD, and CommLink 5 1. Connect the CommLink 5 to the MiniLink PD by using 2 conductor shielded cable to connect from the CommLink’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Network Loop”. Use the 110 VAC/24 VAC power supply furnished with the CommLink for its power source. Be sure to maintain polarity on all boards. The Loop switch on the back of the CommLink 5 should be set to “Multiple”. Also connect a 24 VAC 6 VA minimum transformer to the MiniLink PD power terminal using 18 gauge minimum, 2 wire cable. VCM-X Component & Systems Wiring System Installation Networked Multiple Loop 2. 3. 4. 5. Connect all controllers in a daisy chain format using 2 conductor shielded cable to connect from the controller’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Local Loop”. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 8 VA minimum, transformer for the VCM-X E-BUS Controller and wire from the transformer to the VCM-X E-BUS Controller. Then wire from the VCM-X E-BUS Controller’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Local Loop”. From either the MiniLink PD connector marked “Local Loop” or the VCM-X E-BUS Controller’s 3 wire communications connector, wire to the first VAV/Zone Controller’s 3 wire communications terminal. Using 18 gauge minimum, 2 wire cable, connect all of the associated Non-Modular VAV/Zone Controllers in a daisy chain format using 18 gauge, 2 conductor shielded cable for communications. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 6 VA minimum, transformer for each Non-Modular VAV/Zone Controller and wire from each transformer to its VAV/Zone Controller. WattMaster recommends you use a separate transformer for each VAV/Zone Controller as stated. As an alternative, it is allowable to have several Non-Modular VAV/Zone Controllers share one properly sized transformer (6 VA per VAV/Zone Controller). Warning: Polarity must be observed on all of the VAV/Zone Controllers or damage to the controllers will result. Use 18 gauge minimum, 2 wire cable for all power wiring and be sure to maintain polarity on all boards. The Modular System Manager can connect to any VAV/ Zone Controller or to the VCM-X E-BUS Controller. Use the supplied pigtail cable which has a modular connector for connection to the back of the Modular System Manager and wire to any controller on the communications local loop with communication wire terminals. A separate transformer is required for the Modular System Manager. Connect the 2 power wires from the pigtail connector to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power. The Communications setting must be set to Lo Speed Network Mode. The System Manager TS II utilizes a 3 wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. Since you are using Modular VAV/Zone Controllers, you can use a modular pigtail connector that has a modular connector on one end and stripped wires on the other to connect the System Manager TS II to the Power/Comm board or one of the Modular VAV/Zone Controllers. A separate transformer is required for the System Manager TS II. It has a 2 wire 24 VAC terminal block for connection to a VCM-X Component & Systems Wiring 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using 18 gauge minimum wire. In the Settings Menu, enter <63> for the System Manager Address. 6. The Modular Service Tool SD will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. 7. Before powering up the controllers, set each VAV/ Zone Controller’s board address to a unique number from 1 through 58. Address the VCM-X E-BUS Controller at 59. Set MiniLink PD’s address at 1. Networked Multiple Loop Systems See Figures 10-11, pages 29-30 of this manual for detailed Networked Multiple Loop System wiring diagrams. Also see pages 9-10 for wire and transformer sizing information. You should review these diagrams before attempting connections or powering up the controller or interface devices. Local Loops containing VCM-X E-BUS Controllers with Modular VAV/Zone Controllers 1. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 8 VA minimum, transformer for the VCM-X E-BUS Controller and wire from the transformer to the VCM-X E-BUS Controller. Using 18 gauge minimum, 2 wire cable for power, install a separate 24 VAC, transformer sized for the required VA load for each Power/Comm board on the loop and wire from each transformer to its Power/Comm board. Observe polarity on all boards. 2. Using 2 conductor shielded cable, connect from the VCM-X E-BUS Controller’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Local Loop”. Use 18 gauge minimum wire for power and observe polarity on all boards. 3. Using a modular cable, connect from the MiniLink PD’S modular connector marked “Local Loop” to the Power/ Comm board’s modular input connector. 4. Using modular cables, connect from the Power/Comm board’s modular output connectors to the VAV/Zone Controllers. The VAV/Zone Controllers connect together using modular cables from each VAV/Zone Controller to the next controller and/or to a Power/Comm board. A maximum of 16 VAV/Zone Controllers are allowed per Power/Comm board. If you have more than 16 VAV/ Zone Controllers, you will need multiple Power/Comm boards. Each Power/Comm board must have its own 24 VAC transformer sized for the total number of VAV/ Zone Controllers connected to it. 17 System Installation Networked Multiple Loop 5. Repeat the above steps for each local loop containing VCM-X E-BUS Controllers with VAV/Zone Controllers. 6. The Modular System Manager can connect to any VAV/Zone Controller on the entire system or directly to one of the Power/Comm board’s modular output connectors using modular cable. The Modular Service Tool will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controllers is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. 7. The System Manager TS II utilizes a 3 wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. Since you are using Modular VAV/Zone Controllers, you can use a modular pigtail connector that has a modular connector on one end and stripped wires on the other to connect the System Manager TS II to the Power/Comm board or one of the Modular VAV/Zone Controllers. A separate transformer is required for the System Manager TS II. It has a 2 wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using 18 gauge minimum wire. 8. The Modular Service Tool SD will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. 9. Using 2 conductor shielded cable, connect from the CommLink 5’s 3 wire communications connector to one of the MiniLink PD’s 3 wire communications connector marked “Network Loop”. The Loop switch on the back of the CommLink 5 must be set to “Multiple”. The CommLink 5 only needs to be connected to one of the MiniLink PDs on the system. Warning: Each Power/Comm board must have its own 24 VAC transformer for its power source. This transformer cannot be shared with any other board. Do not ground the transformer that is connected to the Power/Comm board. The transformer should be sized for the required VA by using the information found on pages 9-10 of this manual. Local Loops containing VCM-X E-BUS Controllers with Non-Modular VAV/Zone Controllers 1. Using 18 gauge minimum, 2 wire cable for power, install a 24 VAC, 8 VA minimum, transformer for the VCM-X E-BUS Controller and wire from the transformer to the VCM-X E-BUS Controller. 2. Using 2 conductor shielded cable, connect from the VCM-X E-BUS Controller’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Local Loop”. Use 18 gauge minimum wire for power and observe polarity on all boards. 3. Using 2 conductor shielded cable, connect from the VCM-X E-BUS Controller’s 3 wire communications connector to the VAV/Zone Controllers. The VAV/Zone Controllers connect together using modular cables from each VAV/Zone Controller to the next controller and/or to a Power/Comm Board. A maximum of 16 VAV/Zone controllers are allowed per Power/Comm board. If you have more than 16 VAV/Zone controllers, you will need multiple Power/Comm boards. Each Power/Comm board must have its own 24 VAC transformer sized for the total number of VAV/Zone controllers connected to it. 4. Repeat the above steps for each local loop containing VCM-X E-BUS Controllers with VAV/Zone Controllers. 5. The Modular System Manager can connect to any VAV/Zone Controller on the entire system or directly to one of the Power/Comm board’s modular output connectors using modular cable. The Modular Service Tool will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controllers is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. 6. The System Manager TS II utilizes a 3 wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. A separate transformer is required for the System Manager TS II. It has a 2 wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 10. Using a modular cable, connect from each MiniLink PD’s modular connector marked “Network Loop” to the next MiniLink PD’s “Network Loop” modular input connector using modular cable. Connect all the remaining MiniLink PD’s in the same manner using a daisy chain format. 11. Before powering up the controllers, set each VAV/ Zone Controller’s board address to a unique number from 1 through 58. Address the VCM-X E-BUS Controller at 59. Set MiniLink PD’s address from 1 to 60. Note: Both power and communications are transferred from the Power/Comm board to the VAV/Zone Controllers and the Modular System Manager. 18 VCM-X Component & Systems Wiring System Installation Networked Multiple Loop 6 VA minimum power and should be connected using 18 gauge minimum wire. In the Settings Menu, enter <63> for the System Manager Address. 7. 8. 9. The Modular Service Tool SD will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controller is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. Using 2 conductor shielded cable, connect from the CommLink 5’s 3 wire communications connector to one of the MiniLink PD’s 3 wire communications connector marked “Network Loop”. The Loop switch on the back of the CommLink 5 must be set to “Multiple”. The CommLink only needs to be connected to one of the MiniLink PDs on the system. Using a modular cable, connect from each MiniLink PD’s modular connector marked “Network Loop” to the next MiniLink PD’s “Network Loop” modular input connector using modular cable. Connect all the remaining MiniLink PD’s in the same manner using a daisy chain format. 10. Before powering up the controllers, set each VAV/ Zone Controller’s board address to a unique number from 1 through 58. Address the VCM-X E-BUS Controller at 59. Set MiniLink PD’s address from 1 to 60. Loops Containing VCM-X E-BUS Controllers without VAV/ Zone Controllers 1. Connect all VCM-X E-BUS Controllers on the loop in a daisy chain format using 18 gauge minimum, 2 conductor shielded cable for communications. Install a separate 24 VAC, 8 VA minimum, transformer for each controller and wire to its transformer using 18 gauge minimum, 2 wire cable for power. Observe polarity on all boards. 2. Connect 2 conductor shielded cable from one of the controller’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Local Loop”. Use 18 gauge wire for power and observe polarity on all boards. 3. 4. Only one MiniLink PD on the system should connect to the CommLink. Install a separate 24 VAC, 8 VA minimum, transformer for each MiniLink PD and wire to transformer using 18 gauge minimum, 2 wire cable for power. Observe polarity on all boards. Each MiniLink PD’s address switch should be set with a unique address between 1 and 60. 5. Using a modular cable, connect from the each MiniLink PD’s modular connector marked “Network Loop” to the next MiniLink PD’s “Network Loop” modular input connector using modular cable. Connect all the remaining MiniLink PD’s in the same manner using a daisy chain format. 6. The Modular Service Tool will connect to any of the controllers using the supplied cable with DIN connectors on both ends. The connection point on the controllers is located near the communications connector. The Communications setting must be set to Lo Speed Network Mode. 7.. The Modular System Manager is supplied with a 12 foot modular cable with a modular connector on one end and stripped wires on the other. If the Modular System Manager is to be mounted in remote location, run 18 gauge, 2 conductor shielded cable for communications from one controller’s 3 wire terminal connector to one of the MiniLink PD’s in the same manner using a daisy chain format. The Communications setting must be set to Lo Speed Network Mode. 8. The System Manager TS II utilizes a 3 wire communication terminal block for connection to any controller on the communications local loop that has communication wire terminals. A separate transformer is required for the System Manager TS II. It has a 2 wire 24 VAC terminal block for connection to a 24 VAC transformer. The transformer should be sized to provide 6 VA minimum power and should be connected using 18 gauge minimum wire. In the Settings Menu, enter <63> for the System Manager Address. 9. Address the VCM-X E-BUS Controllers from 1 to 59. Connect 2 wire shielded cable from the CommLink 5’s 3 wire communications connector to the MiniLink PD’s 3 wire communications connector marked “Network Loop”. The Loop switch on the back of the CommLink 5 must be set to “Multiple”. Use the 110 VAC/24 VAC power supply furnished with the CommLink for its power source. VCM-X Component & Systems Wiring 19 System Commissioning Overview The following information is a brief overview of the procedures required to commission a typical Orion System. Select the type of system that you have and follow the procedures listed for that system. Networked Systems 1. Address each MiniLink PD from 1 to 60. 2. On a loop of VCM-X E-BUS Controllers, address the controllers from 1 to 59. 3. On a VAV or Zoning system, address VAV/Zone Controllers from 1 to 58. Address the VCM-X E-BUS Controller at 59. 4. On a VAV or Zoning system, apply power in the following order: a. VCM-X E-BUS Controller b. MiniLink Polling Device c. CommLink 5 d. Power/Comm boards 5. Verify diagnostics LED indicator for proper operation of all controllers. See the technical guide for the specific controller in order to locate the diagnostic LED and controller start-up sequence. Stand Alone System 1. Be sure that the controller is set at address 1. 2. Apply power to the controller. 3. Verify diagnostics LED indicator for proper operation. See the technical guide for the specific controller in order to locate the diagnostic LED and controller startup sequence. 4. Connect an operator’s interface device to the controller for programming the controller. Interconnected System 1. Be sure that the controllers are addressed from 1 to 60. 2. Apply power to the controllers. 6. 3. Verify diagnostics LED indicator for proper operation of all controllers. See the technical guide for the specific controller in order to locate the diagnostic LED and controller start-up sequence. If a computer is used, connect it to the CommLink 5 to access all of the controllers on the entire system for programming. 7. If a computer is not used, and if a Modular System Manager is not already connected on the local loop, connect a Modular Service Tool or System Manager TS II to one of the controllers to perform programming of all controllers on the entire system. 4. 20 Connect an operator’s interface to one of the controllers for programming all of the controllers. VCM-X Component & Systems Wiring System Configurations VCM-X Component & System Wiring 21 1002 1002 R29 R24 R27 R14 1002 L5 R40 R42 R17 R26 C45 X2 .1uF C50 C51 C5 .1uF .1uF R37 1002 .1uF C4 66.000Mhz 1002 1002 1002 1002 1002 D12 R46 R43 J3 C16 TERM C18 .1uF .1uF .1uF C19 R48 1002 R45 R1 R7 T R9 1002 1002 C26 C9 C12 C15 330uF C24 + C7 .1uF D1 5V MADE IN USA WattMaster Controls, Inc WQVGA Graphical Interface YS102178 R4 R11 1002 C13 .1uF LTC3824 .1uF 1002 R15 C29 .1uF U11 Q2 .1uF 2.5V C34 C40 SERIAL # 3.3V OFF 1002 U13 L1 SW1 R35 1002 1002 C11 C1 1002 330uF 50V R S J1 .1uF R13 C14 .1uF 1002 .1uF .1uF .1uF R12 5V T R 1002 1002 1002 GND R39 R23 R21 R S T 6 9 - 8 0 7 DEC PREV ESC ENTER DOWN CLEAR NEXT ALARMS OVERRIDES SCHEDULES SETPOINTS STATUS + Modular System Manager SD (Front Side Shown) MINUS 3 2 5 1 4 UP Connect To Modular I/O Connectors Located On Back Of The System Manager System Manager TS II (Back Side Shown) 1002 1002 1002 .1uF 1002 C8 C6 X3 OPT4 C10 .1uF C39 RTC CAL 1002 R36 .1uF C20 R16 .1uF OPT3 R10 1002 1002 1002 R6 R5 1002 1002 C17 R47 OPT2 C36 1002 C41 R20 C23 R49 R44 1002 1002 R2 V1 R22 .1uF 1002 R32 OPT1 1002 1002 R34 For Stand Alone Applications Both Jumpers Must Be ON R41 R8 R18 1002 R31 D2 1002 1002 C27 U10 C28 R25 C31 R19 R28 R33 C32 R30 Typical Stand Alone System T SHLD R Line Voltage 24 VAC (6 VA) Connect MIni Din Connector Cable Ends To Female Connectors on Modular Service Tool And VCM-X Controller FILENAME WARNING OBSERVE POLARITY 1 of 1 PAGE S. Olson Wiring & Connection Diagram VCM-X E-BUS Stand Alone System DESCRIPTION: DATE: 05/12/15 BY: JOB NAME O-VCMX-Sys-Stand-Alone-1A.CDR 24 VAC (8 VA) VCM-X Unit Controller Line Voltage Modular Service Tool SD Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R T G R GREEN (GND) CLEAR (GND) RED (24 VAC) BLACK (R) DRAIN WIRE (SHLD) WHITE (T) Line Voltage 24 VAC (6 VA) Connect To T, R & S Terminals On VCM-X Controller Note: Either A Modular System Manager SD, System Manager TS II, Modular Service Tool SD Or PC With Prism 2 Software Installed Can Be Used To Program And Configure The Orion System. For Computer Connection Information, See The Computer And Remote Connection Section Of This Manual. BLACK (R) BARE (S) WHITE (T) TERM U9 D11 L4 C35 C2 1002 C30 1002 .1uF 1002 .1uF .1uF C3 C25 .1uF 1002 1002 .1uF 1002 .1uF .1uF .1uF 8.00Mhz RED (24 VAC) BROWN (GND) 22 .1uF .1uF .1uF 485 LOOP Stand Alone System Zone Zone Figure 3: Stand Alone System Wiring VCM-X Component & Systems Wiring 1002 1002 1002 R22 R24 R27 R14 1002 R36 C8 C6 .1uF R17 R26 C45 X2 L5 R40 R42 .1uF C20 C50 C51 C5 .1uF .1uF R37 1002 .1uF C4 C18 C16 .1uF 1002 1002 D12 1002 1002 1002 TERM .1uF .1uF C19 J3 R46 R43 R48 1002 R45 J1 T R9 330uF 50V R S C12 C15 330uF C24 + C7 .1uF 5V D1 R11 1002 C26 C13 R7 C34 LTC3824 U11 Q2 .1uF 2.5V C40 SERIAL # .1uF 1002 R15 C29 .1uF 3.3V R35 1002 1002 U13 L1 SW1 1002 C11 1002 R13 R8 C9 1002 OFF R16 MADE IN USA .1uF .1uF 1002 .1uF .1uF .1uF R39 R23 R21 5V T R 1002 1002 1002 GND VCM-X Component & Systems Wiring To Next HVAC Unit Controller On Loop Up To 60 Controllers Can Be Interconnected R S T 6 9 - 8 0 7 DEC PREV ESC ENTER DOWN CLEAR NEXT ALARMS OVERRIDES SCHEDULES SETPOINTS STATUS + 24 VAC (8 VA) VCM-X E-BUS Unit Controller Modular System Manager SD (Front Side Shown) MINUS 3 2 5 1 4 UP Connect To Modular I/O Connectors Located On Back Of The System Manager Line Voltage Note: Either A Modular System Manager SD, System Manager TS II, Modular Service Tool SD Or PC With Prism 2 Software Installed Can Be Used To Program And Configure The Orion System. For Computer & Remote Connection Information, See The Computer Connection Section Of This Manual. System Manager TS II (Back Side Shown) 1002 1002 1002 .1uF 1002 1002 R1 C1 1002 .1uF OPT4 C10 .1uF C39 RTC CAL .1uF D11 C14 1002 66.000Mhz 1002 1002 R2 R6 R5 V1 1002 X3 OPT3 R10 R29 C17 R47 OPT2 C36 1002 C41 .1uF R32 1002 1002 OPT1 1002 1002 1002 C30 1002 R41 WattMaster Controls, Inc WQVGA Graphical Interface YS102178 R4 .1uF 1002 R18 1002 R31 D2 R20 C23 1002 R49 R44 C27 U10 C28 R25 C31 R19 R28 R33 C32 R30 L4 C35 R34 For Stand Alone Applications Both Jumpers Must Be ON BLACK (R) BARE (S) WHITE (T) TERM U9 R12 C2 .1uF 8.00Mhz C25 .1uF 1002 .1uF .1uF 1002 .1uF 1002 C3 .1uF .1uF 1002 .1uF .1uF .1uF 1002 Line Voltage GREEN (GND) CLEAR (GND) RED (24 VAC) BLACK (R) 24 VAC (8 VA) POLARITY 1 of 1 Wiring & Connection Diagram VCM-X E-BUS Interconnected System DESCRIPTION: DATE: 05/12/15 BY: S. Olson JOB NAME O-VCMX-Sys-InterConnect-1A.CDR FILENAME 24 VAC (8 VA) WARNING OBSERVE PAGE T SHLD R Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R T G R VCM-X E-BUS Unit Controller Line Voltage VCM-X E-BUS Unit Controller Line Voltage 24 VAC (6 VA) Modular Service Tool SD DRAIN WIRE (SHLD) WHITE (T) Line Voltage 24 VAC (6 VA) Connect To T, R & S Terminals On VCM-X Controller Connect MIni Din Connector Cable Ends To Female Connectors on Modular Service Tool And VCM-X Controller 485 LOOP Typical Interconnected System Interconnected System WARNING OBSERVE POLARITY WARNING OBSERVE POLARITY Figure 4: Interconnected System Wiring 23 RED (24 VAC) BROWN (GND) 1002 1002 1002 R29 R22 R27 R24 R14 1002 R36 C8 C6 .1uF R17 R26 C45 X2 L5 R40 R42 C50 C51 C5 .1uF .1uF R37 1002 .1uF C4 C18 C16 1002 1002 1002 D12 1002 1002 TERM .1uF .1uF J3 R46 R43 R48 1002 R45 J1 T 330uF 50V R S R9 1002 C26 C9 C12 C15 330uF C24 + C7 .1uF D1 5V MADE IN USA WattMaster Controls, Inc WQVGA Graphical Interface YS102178 R4 R11 1002 C13 R7 C34 LTC3824 .1uF 1002 R15 C29 .1uF 3.3V U11 Q2 .1uF 2.5V C40 SERIAL # OFF R35 1002 1002 U13 L1 SW1 1002 C11 1002 .1uF 1002 .1uF .1uF .1uF 5V T R R39 R23 1002 1002 1002 GND R21 ACT LNK BAUD Back View LOOP COMPUTER USB GND 485 LOOP POWER R (+) To Next HVAC Unit Controller On Loop Up To 60 Controllers Can Be Interconnected Note: CommLink Must Be Set For Multiple Loop Operation When Used With A MiniLink Whether It Is A Single Loop System Or Not. If it Doesn’t Have A MiniLink Set It To Single Loop. DIAG 10/100 ETHERNET MULTIPLE SINGLE Serial # Note: Either A Modular System Manager SD, System Manager TS II, Modular Service Tool SD Or PC With Prism 2 Software Installed Can Be Used To Program And Configure The Orion System. For Computer And Remote Connection Information, See The Computer Connection Section Of This Manual. + Line Voltage 24 VAC (8 VA) VCM-X E-BUS Unit Controller 110 VAC To 24 VAC Power Pack T BLACK (R) BARE (S) WHITE (T) R S Line Voltage 24 VAC (6 VA) Connect To T, R & S Terminals On VCM-X Or VAV/Zone Controller TB1 6 9 - 8 0 7 DEC PREV ESC ENTER DOWN CLEAR NEXT ALARMS OVERRIDES SCHEDULES SETPOINTS STATUS Line Voltage Modular Service Tool SD Modular System Manager SD MINUS 3 2 5 1 4 UP Connect To Modular I/O Connectors Located On Back Of The System Manager T SHLD R Line Voltage 24 VAC (6 VA) 24 VAC (8 VA) DESCRIPTION: 05/12/15 POLARITY Wiring & Connection Diagrams VCM-X E-BUS Networked System - Single Loop DATE: BY: S. Olson JOB NAME Line Voltage 24 VAC (8 VA) WARNING OBSERVE 1 of 5 PAGE 24 VAC (8 VA) VCM-X E-BUS Unit Controller Line Voltage O-VCMX-Network-SingleLoop1A.CDR FILENAME VCM-X E-BUS Unit Controller Connect MIni Din Connector Cable Ends To Female Connectors on Modular Service Tool And VCM-X E-BUS Controller Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R T G R GREEN (GND) CLEAR (GND) RED (24 VAC) BLACK (R) DRAIN WIRE (SHLD) WHITE (T) VCM-X E-BUS Unit Controller POLARITY HIGH LOW WARNING OBSERVE Front View CommLink 5 SHLD Note: The System Manager TS II Wiring Is Typical For All System Types And Configurations. It Is Shown On This Page Only To Conserve Space. System Manager TS II 1002 1002 1002 .1uF 1002 1002 .1uF C19 R1 C1 1002 .1uF R16 1002 C10 .1uF C39 RTC CAL .1uF C20 .1uF OPT4 C14 1002 66.000Mhz OPT2 R10 1002 X3 1002 1002 R6 R5 1002 1002 C17 R47 OPT3 .1uF C28 1002 1002 R49 R44 C27 U10 .1uF 1002 R2 V1 R25 C31 R19 R28 R33 C32 R30 R32 R34 C41 R13 R8 R18 R20 C23 R41 1002 C30 OPT1 1002 1002 R31 D2 C36 .1uF T (-) RED (24 VAC) BROWN (GND) Typical Single Loop Networked System With CommLink 5 Only 24V For All Applications With CommLink(s) Or MiniLink(s), Both Jumpers Must Be OFF. U9 D11 L4 C35 C2 1002 1002 R12 1002 .1uF C3 .1uF .1uF 1002 C25 .1uF 1002 1002 .1uF .1uF .1uF 8.00Mhz 24 .1uF .1uF .1uF 485 LOOP TERM Networked Single Loop System Zone Zone WARNING OBSERVE POLARITY WARNING OBSERVE POLARITY Figure 5: Networked Single Loop System With CommLink Only Wiring VCM-X Component & Systems Wiring CX2 POWER U12 D5 C7 R27 C11 THERM 0-10V 4-20mA AIN2 OFF=0-5V AIN1 C8 THERM 0-10V 4-20mA CX15 P4 LD6 PROC. DRIVER 1 LOCAL LOOP U15 R25 VREF LED 2 CX13 R4 V1 R31 LOOP DRIVER MiniLink PD LD5 CX14 NETWORK DRIVER LD4 ADD P3 Local Local NETWORK LOOP U6 U10 U1 RN3 RN2 CX7 C9 U11 SW1 R30 R29 R28 X2 YS101900PMINILINK POLLING DEVICE REV. 1 U7 R3 CX2 D4 R26 9 - 0 DEC ESC ENTER DOWN CLEAR NEXT ALARMS OVERRIDES SCHEDULES SETPOINTS STATUS R TB2 24 VAC Connect To Other VAV/Zone Controllers On Loop Connect To Other VAV/Zone Controllers On Loop 24 VAC - Size Transformer For Required VA Load 25 P1 VAV/Zone Controller (Modular) REC POWER & COMM DIST. BOARD YS101856 REV. 0 P2 POWER R1 P3 OE282 1 TB1 C1 P5 OE744-31-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE TB1 C1 SHLD T P5 P4 LD1 F1 P1 OE744-31-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE 0 0 2 of 5 PAGE BY: S. Olson Line Voltage Wiring & Connection Diagrams VCM-X E-BUS Networked System - Single Loop DESCRIPTION: DATE: 05/12/15 24 VAC (8 VA) Modular Service Tool SD Connect To Next VAV/Zone Controller On Branch Circuit JOB NAME www.orioncontrols.com O-VCMX-Network-SingleLoop1A.CDR FILENAME VAV/Zone Controller (Modular) 0 Note: A Maximum Of 6 VAV/Zone Controllers Can Be Connected To Each Branch Circuit. A total Of 16 Controllers Are Allowed Per Power/Comm Board. Use Additional Power/Comm Boards For Systems That Exceed 16 Controllers. See The VAV/Zone Controller Wiring Diagram For Power/Comm Board Transformer Sizing And Circuit Design Information. Connect To Other VAV/Zone Controllers On Loop 25 Power/Comm Board Modular System Manager SD PREV 24 VAC - Size Transformer For Required VA Load Line Voltage 6 8 7 MINUS 3 2 5 1 4 UP Connect To Modular I/O Connectors Located On Back Of The System Manager System Manager TS II Power/Comm Board LD1 VAV/Zone Controller (Modular) C10 C1 Line Voltage VCM-X E-BUS Unit Controller OE744-31-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE Connect To Next VAV/Zone Controller On Branch Circuit 24 VAC (6 VA) +5V D1 R24 LED 1 AIN 1 EPROM U3 RV1 CX3 24VAC RAM U4 GND CX4 TB2 U13 R1 U2 U5 AIN 2 C3 CX5 GND CX1 C1 PROCESSORPBOARD YS101818P552 TB1 R2 R PHILIPS SHLD WDOG X1 T U14 CX1 POWER / CO OMM U1 CX6 C2 P1 VCM-X Component & Systems Wiring 4A U6 C4 TB3 VAC R P3 T R1 D1 X1 Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R POLARITY V1 OFF CX6 T SHLD R WARNING OBSERVE POWER & COMM OUT Note: For System Manager TS II Wiring, See Figure 3. POWER / CO OMM COMMP IN C3 485 LOOP POWER SHLD 24 D1 4A Note: Either A Modular System Manager SD, System Manager TS II, Modular Service Tool SD Or PC With Prism 2 Software Installed Can Be Used To Program And Configure The Orion System. For Computer And Remote Connection Information, See The Computer Connection Section Of This Manual. V1 TB2 TB4 POWER & COMM DIST. BOARD YS101856 REV. 0 P5 R POWER & COMM OUT P2 1 2 4 8 16 32 T G R POWER / CO OMM COMMP IN Typical Single Loop Networked System With MiniLink Polling Device & Modular VAV/Zone Controllers Networked Single Loop System SHLD T P4 www.orioncontrols.com F1 OE282 1 REC www.orioncontrols.com OE282 1 REC Figure 6: Networked Single Loop System With MiniLink PD And Modular VAV/Zone Controllers Wiring 25 R27 C11 0-10V C8 AIN2 OFF=0-5V AIN1 THERM 0-10V 4-20mA CX15 P4 LD6 1 U15 LOCAL LOOP PROC. DRIVER LOOP DRIVER LD5 NETWORK DRIVER CX14 R26 R25 24VAC Local C9 U11 SW1 R30 R29 R28 X2 YS101900PMINILINK POLLING DEVICE REV. 1 CX7 R3 C10 C1 D4 CX2 VREF System Manager TS II 6 9 - 8 0 7 DEC PREV ESC ENTER DOWN UP CLEAR NEXT STATUS SETPOINTS ALARMS OVERRIDES SCHEDULES VAV/Zone Controller (Non-Modular) R T REC TB3 24 VAC GND 24VAC GND STAT TB3 0 TB2 SHLD REC OE282 TB3 OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE TB3 SHLD R T TB2 SHLD REC www.orioncontrols.com 0 OE282 1 24VAC R T 24 VAC GND SHLD R T GND STAT OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE TB2 SHLD REC OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE 0 0 3 of 5 PAGE BY: S. Olson DESCRIPTION: 05/12/15 Line Voltage Wiring & Connection Diagrams VCM-X E-BUS Networked System - Single Loop DATE: 24 VAC (8 VA) Modular Service Tool SD VAV/Zone Controller (Non-Modular) JOB NAME 1 O-VCMX-Network-SingleLoop1A.CDR FILENAME Line Voltage 24 VAC (6 VA) SHLD VAV/Zone Controller (Non-Modular) Line Voltage 24 VAC (6 VA) www.orioncontrols.com Note: Multiple VAV/Zone Controllers Can Be Connected To A Single Transformer If Desired. However Polarity Must Be Observed Or Damage To The Controller(s) Will Result. See The Non- Modular Transformer Sizing Page In This Manual For Transformer Sizing And Circuit Design Information. Line Voltage 24 VAC (6 VA) GREEN (GND) CLEAR (GND) RED (24 VAC) BLACK (R) DRAIN WIRE (SHLD) WHITE (T) VCM-X E-BUS Unit Controller TB2 VAV/Zone Controller (Non-Modular) Line Voltage 24 VAC (6 VA) Modular System Manager SD MINUS 3 2 5 1 4 Connect To Modular I/O Connectors Located On Back Of The System Manager Note: For System Manager TS II Wiring, See Figure 3. 485 LOOP Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE Line Voltage 24 VAC (6 VA) RN3 RN2 U7 X1 T SHLD R POLARITY Connect To Next VAV/Zone Controller On Local Loop U6 U10 U1 ADD Local NETWORK LOOP LD4 R24 R4 V1 U3 R31 THERM +5V EPROM GND 4-20mA TB2 C3 T G R WARNING OBSERVE Note: Multiple VAV/Zone Controllers Can Be Connected To A Single Transformer If Desired. However Polarity Must Be Observed Or Damage To The Controller(s) Will Result. See The Non-Modular Transformer Sizing Page In This Manual For Transformer Sizing And Circuit Design Information. D5 C7 CX3 U12 AIN 1 CX2 AIN 2 RAM U4 POWER SHLD CX4 LED 1 GND U14 R1 U2 U5 LED 2 R CX13 T U13 TB3 C3 CX5 24 VAC (6 VA) T CX1 C1 PROCESSORPBOARD YS101818P552 TB1 R2 X1 MiniLink PD SHLD D1 R WDOG PHILIPS TB4 P3 P5 CX1 CX6 1 2 4 8 16 32 U1 CX6 C2 P1 RV1 OFF U6 C4 26 Note: Either A Modular System Manager SD, System Manager TS II, Modular Service Tool SD Or PC With Prism 2 Software Installed Can Be Used To Program And Configure The Orion System. For Computer And Remote Connection Information, See The Computer Connection Section Of This Manual. Typical Single Loop Networked System With MiniLink Polling Device & Non-Modular VAV/Zone Controllers Networked Single Loop System Zone Zone www.orioncontrols.com OE282 1 24VAC R T 24 VAC GND SHLD R T GND STAT www.orioncontrols.com OE282 1 24VAC R T 24 VAC GND SHLD R T GND STAT Figure 7: Networked Single Loop System With MiniLink PD And Non Modular VAV/Zone Controllers Wiring VCM-X Component & Systems Wiring ACT LNK BAUD Back View LOOP COMPUTER USB 24 VAC (6 VA) LED 1 V1 CX2 POWER R25 VREF R4 LED 2 U12 D4 R26 C11 THERM 0-10V 4-20mA AIN2 OFF=0-5V AIN1 C8 THERM 0-10V 4-20mA P4 LD6 LOCAL LOOP PROC. DRIVER LOOP DRIVER LD5 NETWORK DRIVER NETWORK LOOP LD4 U6 U10 U1 RN3 RN2 CX7 C9 U11 C10 9 - 0 ESC ENTER DOWN UP CLEAR NEXT STATUS ALARMS OVERRIDES SCHEDULES SETPOINTS 25 Connect To Other VAV/Zone Controllers On Loop Connect To Other VAV/Zone Controllers On Loop C1 SHLD T P5 P4 LD1 F1 P1 Note: A Maximum Of 6 VAV/Zone Controllers Can Be Connected To Each Branch Circuit. A total Of 16 Controllers Are Allowed Per Power/Comm Board. Use Additional Power/Comm Boards For Systems That Exceed 16 Controllers. See The VAV/Zone Controller Wiring Diagram For Power/Comm Board Transformer Sizing And Circuit Design Information. Connect To Other VAV/Zone Controllers On Loop 24 VAC - Size Transformer For Required VA Load Power/Comm Board Modular System Manager SD PREV 25 Power/Comm Board 24 VAC - Size Transformer For Required VA Load TB1 SW1 R30 R29 R28 X2 YS101900PMINILINK POLLING DEVICE REV. 1 U7 6 8 7 MINUS 5 4 DEC Line Voltage 110 VAC To 24 VAC Power Pack 3 2 1 Connect To Modular I/O Connectors Located On Back Of The System Manager System Manager TS II Line Voltage Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R VAV/Zone Controller OE744-31-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE 0 Local 485 LOOP POWER Serial # CX1 T SHLD R 4 of 5 PAGE BY: JOB NAME Line Voltage Connect To Next VAV/Zone Controller On Branch Circuit S. Olson DESCRIPTION: 05/12/15 VAV/Zone Controller 24 VAC (8 VA) Modular Service Tool SD Wiring & Connection Diagrams VCM-X Networked System - Single Loop DATE: O-VCMX-Net-SingleLoop1A.CDR FILENAME Connect To Next VAV/Zone Controller On Branch Circuit VCM-X E-BUS Unit Controller REC Network D5 C7 CX15 RV1 CX2 MiniLink PD Loop 1 +5V EPROM U3 R31 RAM U4 CX3 Note: See Computer & Accessories Connection Section Of This Manual For Optional Computer and Remote Connection Diagrams. DIAG 10/100 ETHERNET GND 1 MULTIPLE SINGLE Front View CommLink 5 HIGH LOW AIN 1 R1 U2 CX4 24VAC R (+) C3 U5 GND SHLD CX1 CX5 TB1 T (-) R2 C1 PROCESSORPBOARD YS101818P552 AIN 2 WDOG PHILIPS X1 R27 GND U1 CX6 C2 P1 TB2 U6 C4 CX13 VAC P3 U15 R1 SHLD POWER OFF Note: CommLink Must Be Set For Multiple Loop Operation When Used With A MiniLink Whether It Is A Single Loop System Or Not. If it Doesn’t Have A MiniLink Set It To Single Loop. 4A 24V Note: For System Manager TS II Wiring, See Figure 3. D1 24 POWER & COMM OUT V1 TB2 T POWER & COMM DIST. BOARD YS101856 REV. 0 U13 COMMP IN Note: Either A Modular System Manager SD, System Manager TS II, Modular Service Tool SD Or PC With Prism 2 Software Installed Can Be Used To Program And Configure The Orion System. For Computer And Remote Connection Information, See The Computer Connection Section Of This Manual. POWER / CO OMM R R 4A VCM-X Component & Systems Wiring P2 D1 P1 R24 VAC CX14 P3 C1 R1 R3 485 LOOP POWER U14 LD1 R D1 24 1 T P5 OE282 SHLD V1 TB2 POWER & COMM OUT P2 X1 POWER & COMM DIST. BOARD YS101856 REV. 0 C3 R 0 TB3 T www.orioncontrols.com TB4 SHLD CX6 C1 P3 TB1 OE744-31-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE P5 POLARITY ADD WARNING OBSERVE 1 2 4 8 16 32 T G R POWER / CO OMM COMMP IN Typical Single Loop Networked System With MiniLink Polling Device, CommLink & Modular VAV/Zone Controllers Networked Single Loop System P4 www.orioncontrols.com OE282 1 F1 REC Figure 8: Networked Single Loop System With CommLink & MiniLink PD - Modular VAV/Zone Controllers 27 ACT LNK COMPUTER USB BAUD Back View LOOP MULTIPLE SINGLE Front View HIGH LOW 24 VAC (6 VA) VREF LED 1 R4 V1 CX2 POWER LED 2 R25 RV1 D4 R26 U12 C11 THERM 0-10V 4-20mA Serial # THERM 0-10V 4-20mA LD6 P4 LOCAL LOOP PROC. DRIVER LOOP DRIVER LD5 NETWORK DRIVER RN3 RN2 CX7 C9 U11 C10 ESC ENTER DOWN UP CLEAR NEXT STATUS SETPOINTS ALARMS OVERRIDES SCHEDULES Line Voltage 24 VAC (6 VA) T 24 VAC GND SHLD R 24VAC GND STAT www.orioncontrols.com OE282 1 24VAC R T 24 VAC GND SHLD R T GND STAT Note: Multiple VAV/Zone Controllers Can Be Connected To A Single Transformer If Desired. However Polarity Must Be Observed Or Damage To The Controller(s) Will Result. See The Non- Modular Transformer Sizing Page In This Manual For Transformer Sizing And Circuit Design Information. Line Voltage 24 VAC (6 VA) VAV/Zone Controller (Non-Modular) 24 VAC (6 VA) FILENAME Line Voltage 24 VAC (6 VA) 24VAC GND STAT 5 of 5 PAGE 24 VAC (8 VA) BY: S. Olson JOB NAME Connect To Next VAV/Zone Controller On Local Loop Line Voltage Modular Service Tool SD VAV/Zone Controller (Non-Modular) Wiring & Connection Diagrams VCM-X Networked System - Single Loop DESCRIPTION: DATE: 05/12/15 O-VCMX-Net-SingleLoop1A.CDR VAV/Zone Controller (Non-Modular) Line Voltage R SW1 R30 R29 R28 X2 YS101900PMINILINK POLLING DEVICE REV. 1 U7 PREV Modular System Manager SD MINUS - 9 8 7 0 6 DEC 3 2 5 1 4 GREEN (GND) CLEAR (GND) RED (24 VAC) BLACK (R) DRAIN WIRE (SHLD) WHITE (T) VCM-X E-BUS Unit Controller GND Local NETWORK LOOP LD4 U6 U10 U1 110 VAC To 24 VAC Power Pack TB1 Connect To Modular I/O Connectors Located On Back Of The System Manager System Manager TS II Note: For System Manager TS II Wiring, See Figure 3. Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R T SHLD R 24 VAC Local AIN2 OFF=0-5V AIN1 C8 CX2 T G R R Network D5 C7 485 LOOP POWER 24V MiniLink PD Loop 1 +5V EPROM R31 RAM U3 Note: See Computer & Accessories Connection Section Of This Manual For Optional Computer and Remote Connection Diagrams. DIAG 10/100 ETHERNET GND C1 CommLink 5 R3 Note: CommLink Must Be Set For Multiple Loop Operation When Used With A MiniLink Whether It Is A Single Loop System Or Not. If it Doesn’t Have A MiniLink Set It To Single Loop. X1 Note: Either A Modular System Manager SD, System Manager TS II, Modular Service Tool SD Or PC With Prism 2 Software Installed Can Be Used To Program And Configure The Orion System. For Computer And Remote Connection Information, See The Computer Connection Section Of This Manual. U2 CX3 24VAC R (+) C3 U4 GND SHLD CX1 CX4 TB1 T (-) R2 U5 AIN 1 PHILIPS CX5 AIN 2 WDOG C1 PROCESSORPBOARD YS101818P552 R27 GND U1 CX6 X1 TB2 CX1 Typical Single Loop Networked System With MiniLink Polling Device, CommLink & Non-Modular VAV/Zone Controllers OFF U6 C2 P1 1 TB3 R1 REC CX15 SHLD U15 TB2 CX13 0 T OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE D1 TB3 R24 REC CX14 SHLD R T SHLD C3 485 LOOP 0 U14 OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE U13 TB2 SHLD R R T T TB3 1 SHLD REC P3 SHLD OE282 TB3 0 TB4 www.orioncontrols.com P5 OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE C4 28 TB2 ADD POLARITY CX6 WARNING OBSERVE 1 2 4 8 16 32 Networked Single Loop System Zone Zone www.orioncontrols.com OE282 1 T Figure 9: Networked Single Loop System With CommLink & MLPD - Non-Modular VAV/Zone Controllers VCM-X Component & Systems Wiring BAUD V1 R31 R26 U12 D5 C7 C11 POWER LED 2 LED 1 RV1 U12 D5 C7 C11 485 LOOP POWER THERM 0-10V 4-20mA AIN2 OFF=0-5V AIN1 C8 THERM 0-10V 4-20mA LD6 LOCAL LOOP LOOP DRIVER LD5 NETWORK DRIVER NETWORK LOOP LD4 THERM 0-10V 4-20mA C8 AIN2 OFF=0-5V AIN1 THERM 0-10V 4-20mA LD6 P4 PROC. DRIVER LOCAL LOOP LOOP DRIVER LD5 NETWORK DRIVER NETWORK LOOP LD4 U6 U10 U1 MiniLink PD Loop 2 P4 PROC. DRIVER U6 U10 U1 RN3 RN2 Serial # C9 U11 RN2 RN3 X1 R3 C10 C1 CX7 C9 U11 C10 9 - 0 ESC ENTER DOWN UP CLEAR NEXT STATUS ALARMS OVERRIDES SCHEDULES SETPOINTS 25 Connect To Other VAV/Zone Controllers On Loop Connect To Other VAV/Zone Controllers On Loop Note: A Maximum Of 6 VAV/Zone Controllers Can Be Connected To Each Branch Circuit. A total Of 16 Controllers Are Allowed Per Power/Comm Board. Use Additional Power/Comm Boards For Systems That Exceed 16 Controllers. See The VAV/Zone Controller Wiring Diagram For Power/Comm Board Transformer Sizing And Circuit Design Information. Connect To Other VAV/Zone Controllers On Loop 24 VAC - Size Transformer For Required VA Load Power/Comm Board Modular System Manager SD PREV 25 Power/Comm Board 24 VAC - Size Transformer For Required VA Load Line Voltage 485 LOOP R T SHLD VAV/Zone Controller VCM-X E-BUS Controller Line Voltage OE744-31-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE 0 1 of 2 PAGE DATE: S. Olson DESCRIPTION: BY: JOB NAME Line Voltage Connect To Next VAV/Zone Controller On Branch Circuit VAV/Zone Controller 24 VAC (8 VA) Modular Service Tool SD Wiring & Connection Diagram Networked System - Multiple Loop 05/07/15 O-VCMX-Net-MultiLoop-1A.CDR FILENAME Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R P5 SW1 R30 R29 R28 X2 YS101900PMINILINK POLLING DEVICE REV. 1 U7 6 8 MINUS 5 4 7 3 2 DEC 1 Line Voltage Network Local SW1 R30 R29 R28 X2 YS101900PMINILINK POLLING DEVICE REV. 1 U7 CX7 TB1 Connect To Modular I/O Connectors Located On Back Of The System Manager 110 VAC To 24 VAC Power Pack C1 Connect To Loop 2 Power/Comm Board & VCM-X Controller 24 VAC (6 VA) Local CX2 POWER D4 Network VREF 1 VREF R4 LED 1 CX2 R25 EPROM U3 CX2 CX13 R1 1 TB1 U15 MULTIPLE SINGLE CX3 R26 R24 LED 2 +5V RAM U4 24 VAC (6 VA) CX4 D4 U14 RV1 CX15 24VAC 24V MiniLink PD Loop 1 U5 R27 Note: CommLink Must Be Set For Multiple Loop Operation TB2 CX15 R1 U2 CX5 R4 ADD LOOP C3 LNK CX1 ACT R2 DIAG COMPUTER USB PHILIPS PROCESSORPBOARD YS101818P552 C1 10/100 ETHERNET WDOG X1 EPROM U3 V1 U1 CX6 C2 P1 CX3 GND GND Back View of CommLink 5 HIGH LOW GND RAM U4 R31 U6 C4 U15 C3 T G R TB1 TB1 SHLD D1 R CX4 AIN 1 CX2 AIN 2 U5 R25 R U2 CX5 R27 T (-) SHLD C3 T U13 TB3 CX14 TB4 CX1 C1 PROCESSORPBOARD YS101818P552 GND R (+) R2 X1 24VAC SHLD T P3 P5 CX1 CX6 Front View of CommLink 5 OFF WDOG PHILIPS CX14 OFF U1 CX6 C2 P1 TB2 F1 +5V P1 AIN 2 4A U6 C4 CX13 VAC U13 P3 AIN 1 LD1 GND D1 24 P4 R P5 SHLD T T SHLD T C1 TB3 TB1 TB4 REC SHLD R1 D1 POWER POWER & COMM OUT V1 TB2 1 R24 POWER & COMM DIST. BOARD YS101856 REV. 0 OE282 U14 0 R COMMP IN Note: Either A Modular System Manager SD, System Manager TS II, Modular Service Tool SD Or PC With Prism 2 Software Installed Can Be Used To Program And Configure The Orion System. For Computer & IP Module Connection Information See The Computer Connection Section Of This Manual. POWER / CO OMM R CX1 4A VCM-X Component & Systems Wiring P2 CX6 P1 P3 VAC www.orioncontrols.com P5 D1 24 P3 ADD R1 1 2 4 8 16 32 POWER C1 LD1 R3 V1 TB2 X1 POWER & COMM DIST. BOARD YS101856 REV. 0 OE744-31-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE C3 POLARITY 1 2 4 8 16 32 WARNING OBSERVE Connect To Loop 3 MiniLink PD R POWER & COMM OUT P2 POWER / CO OMM COMMP IN Typ. Multiple Loop Networked System With Modular VAV/Zone Controllers Networked Multiple Loop System Connections & Wiring SHLD T P4 www.orioncontrols.com OE282 1 F1 REC Figure 10: Networked Multiple Loop System Wiring With Modular VAV/Zone Controllers 29 BAUD U12 R25 POWER LED 2 LED 1 RV1 U12 EPROM U3 C11 R27 THERM 0-10V 4-20mA THERM 0-10V 4-20mA LD6 PROC. DRIVER LOCAL LOOP LOOP DRIVER LD5 Local NETWORK DRIVER NETWORK LOOP LD4 THERM C8 AIN2 THERM LOOP DRIVER NETWORK DRIVER NETWORK LOOP LD4 RN3 C9 X2 C10 VAV/Zone Controller (Non-Modular) 24 VAC (6 VA) FILENAME Line Voltage 24 VAC (6 VA) VCM-X E-BUS Controller GND STAT 2 of 2 S. Olson DESCRIPTION: BY: JOB NAME Connect To Next VAV/Zone Controller On Local Loop VAV/Zone Controller (Non-Modular) 24 VAC (8 VA) Line Voltage Modular Service Tool SD Wiring & Connection Diagram Networked System - Multiple Loop 05/07/15 24 VAC PAGE DATE: O-VCMX-Net-MultiLoop-1A.CDR VAV/Zone Controller (Non-Modular) Line Voltage Note: Multiple VAV/Zone Controllers Can Be Connected To A Single Transformer If Desired. However Polarity Must Be Observed Or Damage To The Controller(s) Will Result. See The Non- Modular Transformer Sizing Page In This Manual For Transformer Sizing And Circuit Design Information. Line Voltage 24 VAC (6 VA) GREEN (GND) CLEAR (GND) RED (24 VAC) BLACK (R) DRAIN WIRE (SHLD) WHITE (T) R GND SW1 R30 R29 R28 STAT LD5 GND P4 PROC. DRIVER T LOCAL LOOP U11 YS101900PMINILINK POLLING DEVICE REV. 1 CX7 ALARMS OVERRIDES SHLD R LD6 RN2 U7 Network GND 0-10V X1 Local SW1 C1 C10 Line Voltage 24 VAC (6 VA) 24 VAC 4-20mA X2 R30 R29 R28 CLEAR STATUS SETPOINTS SCHEDULES Modular System Manager SD ENTER DOWN NEXT T OFF=0-5V AIN1 C9 U11 - 0 DEC ESC UP R 0-10V RN3 RN2 CX7 YS101900PMINILINK POLLING DEVICE REV. 1 U7 9 8 7 PREV 24VAC 4-20mA U6 U10 U1 MiniLink PD Loop 2 P4 U6 U10 U1 6 MINUS 3 2 5 1 4 1 C11 485 LOOP POWER Serial # Connect To Modular I/O Connectors Located On Back Of The System Manager 485 LOOP Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R T SHLD R Connect To Loop 2 VCM-X Controller & VAV/Zone Controllers D5 C7 AIN2 OFF=0-5V AIN1 Network D5 C7 C8 1 MULTIPLE SINGLE CX3 24 VAC (6 VA) CX2 POWER RAM U4 24 VAC (6 VA) U15 VREF R4 V1 R31 R26 24VAC LED 1 +5V R1 1 LED 2 CX2 GND 24V MiniLink PD Loop 1 CX4 VREF CX2 AIN 2 R24 RV1 U5 D4 Note: CommLink Must Be Set For Multiple Loop Operation TB2 U14 LOOP HIGH LOW GND CX15 R1 U2 CX5 R4 P3 LNK C3 ACT CX1 DIAG COMPUTER USB R2 PROCESSORPBOARD YS101818P552 C1 10/100 ETHERNET WDOG PHILIPS X1 TB1 GND Back View of CommLink 5 Front View of CommLink 5 U1 CX6 C2 P1 EPROM U3 V1 ADD 110 VAC To 24 VAC Power Pack OE282 R31 U6 C4 CX3 CX2 AIN 1 CX13 T RAM U4 D4 R U2 CX4 R25 SHLD C3 U5 R26 SHLD T U13 TB3 CX14 TB4 CX1 CX5 24VAC R (+) R2 C1 PROCESSORPBOARD YS101818P552 R27 T (-) SHLD D1 R WDOG PHILIPS X1 CX15 R3 Note: Either A Modular System Manager SD, System Manager TS II, Modular Service Tool SD Or PC With Prism 2 Software Installed Can Be Used To Program And Configure The Orion System. For Computer & IP Module Connection Information See The Computer Connection Section Of This Manual. OFF U1 CX6 C2 P1 CX14 REC CX13 SHLD U15 0 U13 TB2 D1 CX1 CX6 1 2 4 8 16 32 T G R 24VAC TB1 www.orioncontrols.com +5V STAT GND GND TB2 SHLD R AIN 1 GND GND 24 VAC AIN 2 T R R SHLD 24VAC T 0 TB3 T TB4 SHLD R T T R24 OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE 1 U14 TB3 P5 TB3 CX1 REC CX6 SHLD P3 TB2 OE282 R 0 SHLD www.orioncontrols.com P5 OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE ADD TB3 C1 REC R3 SHLD X1 TB2 C3 OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE 1 2 4 8 16 32 POLARITY Connect To Loop 3 MiniLink PD WARNING OBSERVE OFF U6 C4 30 C3 Typ. Multiple Loop Networked System With Non-Modular VAV/Zone Controllers Zone Networked Multiple Loop System Connections Zone& Wiring www.orioncontrols.com OE282 1 T Figure 11: Networked Multiple Loop System Wiring With Non Modular VAV/Zone Controllers VCM-X Component & Systems Wiring VCM-X E-BUS Controller Wiring VCM-X E-BUS Controller Wiring VCM-X Component & Systems Wiring 31 Zone VCM-X E-BUS Controller Wiring Zone Main Controller Wiring For Stand Alone Applications, Connect To System Manager. For Network Applications Connect To Next Controller And/Or MiniLink PD On Local Loop. Note: All Relay Outputs Are Normally Open And Rated For 24 VAC Power Only. 1 Amp Maximum Load. VCM-X E-BUS Controller Local Loop RS-485 9600 Baud RS-485 COMMUNICATION LOOP. WIRE “R” TO “R”, “T” TO “T” “SHLD” TO “SHLD” R - 24VAC RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC G - Fan ON/OFF Only RELAY COMMON All Comm Loop Wiring Is Straight Thru T to T, R to R & SHLD to SHLD FAN RELAY 2 RELAY 3 RELAY 4 RELAY 5 Relay Output Contacts R2 Through R5 May Be UserConfigured For The Following: AAON No.: V07150 VCM-X MODULAR E-BUS CONTROLLER Orion No.:OE332-23E-VCMX-MOD-A 1 - Heating Stages 2 - Cooling Stages 3 - Warm-up Mode Command (VAV Boxes) 4 - Reversing Valve (Air To Air Heat Pumps) 5 - Reheat Control (Dehumidification) 6 - Exhaust Fan Interlock 7 - Preheater For Low Ambient Protection 8 - Alarm 9 - Override 10 - Occupied 11 - OA Damper 12 - Heat Wheel 13 - Emergency Heat AI1 = SPC (SPACE TEMPERATURE SENSOR) AI2 = SAT (SUPPLY AIR TEMPERATURE SENSOR) AI3 = RAT (RETURN AIR TEMPERATURE SENSOR) AI4 = OAT (OUTDOOR AIR TEMPERATURE SENSOR) AI5 = SUCTION PRESSURE SENSOR (FROM EXP. MODULE) AI7 = SPACE TEMPERATURE SENSOR SLIDE ADJUST OR VOLTAGE RESET SOURCE A01 = ECONOMIZER (2-10 VDC OUTPUT) A02 = SUPPLY FAN VFD (0-10 VDC OUTPUT) See Individual Component Wiring Diagrams For Detailed Wiring Of Analog Inputs And Outputs E-BUS CONNECTOR ANALOG INPUT JUMPER SETTINGS LED BLINK CODES STATUS1 STATUS2 NORMAL OPERATION 0 1 SAT FAIL 1 THERM 4-20mA 0-10V 0-5V OAT FAIL 2 SPC FAIL 3 2 MODULE ALARM 4 2 MECH COOL FAIL 1 AI3 THERM 4-20mA 0-10V 0-5V AI4 THERM 4-20mA 0-10V 0-5V THERM 4-20mA 0-10V 0-5V HIGH SAT 2 AI5 CONT. TEMP COOL FAIL 3 CONT. TEMP HEAT FAIL 4 4 THERM 4-20mA 0-10V 0-5V PUSH BUTTON OVR 1 5 ZONE OVR 2 5 OUTPUT FORCE ACTIVE 0 6 AI1 AI1 SET AI2 AI2 SET AI7 THERM 4-20mA 0-10V 0-5V LED NAME 2 3 MECH HEAT FAIL 2 3 FAN PROOF FAIL 3 3 DIRTY FILTER 4 3 EMERGENCY SHUTDOWN 5 3 LOW SAT 1 4 AI3 SET ANALOG INPUT JUMPER SETTINGS MUST BE SET AS SHOWN FOR PROPER OPERATION STATIC PRESSURE 2 WattMaster Label #LB102073-01-A Rev.: 1A Note: A Total Of 20 Relays Are Available By Adding Relay Expansion Modules. All Expansion Module Relay Outputs Are User Configurable As Listed Above. 4 4 GND Line Voltage 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED 2 IC EXPANSION 24VAC 2 IC DIGITAL SENSOR AI4 SET Size Transformer For Correct Total Load. VCM-X E-BUS Controller = 8 VA Jumpers AI5 SET Connect To Digital Room Sensor And/Or Digital CO2 Sensor Splice If Required AI7 SET OE271 Static Pressure Transducer Connect To Expansion Module(s) (When Used) Warning: 24 VAC Must Be Connected So That All Ground Wires Remain Common. Failure To Do So Will Result In Damage To The Controllers. Connect FRP Tubing To High Pressure Port (Bottom Tube) and Route To Static Pressure Pickup Probe Located In Unit Discharge. Leave Port Marked “Lo” Open To Atmosphere JOB NAME FILENAME OVCMX-MainWire-1A.CDR DATE: 01/08/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller 1 of 1 Main Board Wiring Figure 12: OE332-23E-VCM-X-MOD - VCM-X E-BUS Controller Wiring 32 VCM-X Component & Systems Wiring VCM-X E-BUS Controller Wiring Main Controller Addressing VCM-X E-BUS Controller RS-485 COMMUNICATION LOOP. WIRE “R” TO “R”, “T” TO “T” “SHLD” TO “SHLD” RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC RELAY COMMON FAN RELAY 2 RELAY 3 RELAY 4 RELAY 5 Note: The Power To The Controller Must Be Removed And Reconnected After Changing The Address Switch Settings In Order For Any Changes To Take Effect. Caution: Disconnect All Communication Loop Wiring From The Controller Before Removing Power From The Controller. Reconnect Power And Then Reconnect Communication Loop Wiring. AAON No.: V07150 VCM-X MODULAR E-BUS CONTROLLER Orion No.:OE332-23E-VCMX-MOD-A AI1 = SPC (SPACE TEMPERATURE SENSOR) AI2 = SAT (SUPPLY AIR TEMPERATURE SENSOR) AI3 = RAT (RETURN AIR TEMPERATURE SENSOR) AI4 = OAT (OUTDOOR AIR TEMPERATURE SENSOR) AI5 = SUCTION PRESSURE SENSOR (FROM EXP. MODULE) AI7 = SPACE TEMPERATURE SENSOR SLIDE ADJUST OR VOLTAGE RESET SOURCE A01 = ECONOMIZER (2-10 VDC OUTPUT) A02 = SUPPLY FAN VFD (0-10 VDC OUTPUT) ADDRESS ADD This Switch Should Be In The OFF Position As Shown 1 2 4 8 16 32 -------NET E-BUS CONNECTOR ANALOG INPUT JUMPER SETTINGS LED BLINK CODES SPC FAIL 3 2 MODULE ALARM 4 2 MECH COOL FAIL 1 AI3 THERM 4-20mA 0-10V 0-5V AI4 THERM 4-20mA 0-10V 0-5V AI5 THERM 4-20mA 0-10V 0-5V THERM 4-20mA 0-10V 0-5V PUSH BUTTON OVR 1 5 AI7 ZONE OVR 2 5 OUTPUT FORCE ACTIVE 0 6 AI2 2 3 MECH HEAT FAIL 2 3 FAN PROOF FAIL 3 3 DIRTY FILTER 4 3 EMERGENCY SHUTDOWN 5 3 LOW SAT 1 4 HIGH SAT 2 4 CONT. TEMP COOL FAIL CONT. TEMP HEAT FAIL ANALOG INPUT JUMPER SETTINGS MUST BE SET AS SHOWN FOR PROPER OPERATION STATIC PRESSURE 2 WattMaster Label #LB102073-01-A Rev.: 1A 3 4 4 4 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED 2 IC EXPANSION D 2 AD 1 1 OAT FAIL THERM 4-20mA 0-10V 0-5V LED NAME D STATUS2 0 SAT FAIL THERM 4-20mA 0-10V 0-5V AD STATUS1 NORMAL OPERATION AI1 2 IC DIGITAL SENSOR Controller Address Switch Address Switch Shown Is Set For Address 1 Address Switch Shown Is Set For Address 13 The Address For Each Controller Must Be Unique To The Other Controllers On The Local Loop And Be Between 1 and 59 JOB NAME FILENAME O-VCM-X-AddSwSet-1A.CDR DATE: 01/09/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller 1 of 1 Address Switch Setting Figure 13: VCM-X E-BUS Controller Addressing VCM-X Component & Systems Wiring 33 Zone VCM-X E-BUS Controller Wiring Zone Digital Room Sensor & Wall-Mounted CO2 Sensor Wiring I1 SET Note: When Only The Digital Room Sensor Is Used, It Connects Directly To The VCM-X E-BUS Controller Using A TSDRSC Cable Of The Appropriate Length. The Maximum Length Allowed Is 160 Feet. See Figure 19 For Connection When The Space CO2 Sensor Is Also Used. AI1 AI5 AI4 SET AI7 AI3 SET AI4 AI2 AI2 SET AI2 AI3 AI5 SET ALARM Display Override THERM 4-20mA 0-10V 0-5V AI4 THERM 4-20mA 0-10V 0-5V AI5 THERM 4-20mA 0-10V 0-5V AI7 THERM 4-20mA 0-10V 0-5V EMERGENCY SHUTDOWN ANALOG INPUT JUMPER SETTINGS MUST BE SET AS SHOWN FOR PROPER OPERATION AI7 SET OVERRIDE 4-20mA 0-10V 0-5V AI3 STATIC PRESSURE WattMaster Label #LB102033-01 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED I2C DIGITAL SENSOR I2C EXPANSION VCM-X E-BUS Controller TSDRSC Cable OE217-00 / OE217-01 Digital Room Sensor JOB NAME FILENAME O-VCM-X-DigiRoom-1A.CDR DATE: 01/09/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller 1 of 1 Digital Room Sensor Figure 14: OE217-00 / OE217-01 Digital Room Sensor OE256-01 CO2 Sensor I1 SET AI1 AI2 AI3 AI5 AI5 SET AI7 SET Note: When a Digital Room Sensor Is Used In Combination With The CO2 Sensor, The CO2 Sensor Always Connects To The VCX E-BUS Controller First Using a TSDRSC Cable Of The Required Length. The Digital Room Sensor Then Connects To The CO2 Sensor With Another TSDRSC Cable. Mount Sensor(s) At Least 5 Feet Above Floor. See The CO2 Sensor Technical Guide For Further Wiring Details. AI4 SET AI7 AI3 SET AI4 AI2 SET Note: In This Configuration, Set The CO2 Sensor To Address 1. 4-20mA 0-10V 0-5V AI2 AI3 THERM 4-20mA 0-10V 0-5V AI4 THERM 4-20mA 0-10V 0-5V AI5 THERM 4-20mA 0-10V 0-5V AI7 THERM 4-20mA 0-10V 0-5V EMERGENCY SHUTDOWN ANALOG INPUT JUMPER SETTINGS MUST BE SET AS SHOWN FOR PROPER OPERATION STATIC PRESSURE WattMaster Label #LB102033-01 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED I2C DIGITAL SENSOR I2C EXPANSION VCM-X E-BUS Controller OVERRIDE ALARM Display Override TSDRSC Cable TSDRSC Cable OE217-00 / OE217-01 Digital Room Sensor JOB NAME REVISED: 05/12/15 FILENAME O-VCM-X-WallCO2-1A.CDR DATE: 01/09/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller 1 of 1 Wall-Mounted CO2 Sensor Figure 15: OE256-01 Wall-Mounted CO2 Sensor 34 VCM-X Component & Systems Wiring VCM-X E-BUS Controller Wiring Duct-Mounted CO2 Sensor Wiring VCM-X E-BUS Controller RS-485 COMMUNICATION LOOP. WIRE “R” TO COMMUNICATION “R”, “T” TO “T” “SHLD” TOWIRE “SHLD” RS-485 LOOP. “R” TO “R”, “T” TO “T” “SHLD” TO “SHLD” Note: 1.) The CO2 Sensor Always Connects To The VCM-X E-BUS Controller Using A TSDRSC Cable Of The Required Length. If Also Using a Digital Room Sensor, Connect the Digital Room Sensor to the CO2 Sensor Using Another TSDRSC Cable Of The Required Length. The Total Length Of Cable For All Sensor Cables Combined Cannot Exceed 160 Feet. AI1 = SPC (SPACE TEMPERATURE SENSOR) AI1 TEMPERATURE SENSOR) SAT(SPACE (SUPPLY AIR TEMPERATURE SENSOR) AI2==SPC AI2 AIR TEMPERATURE SENSOR) RAT(SUPPLY (RETURN AIR TEMPERATURE SENSOR) AI3==SAT AI3 AIRAIR TEMPERATURE SENSOR) OAT(RETURN (OUTDOOR TEMPERATURE SENSOR) AI4==RAT AI4 (OUTDOOR AIR TEMPERATURE SENSOR) SUCTION PRESSURE SENSOR (FROM EXP. MODULE) AI5==OAT AI5 PRESSURE SENSOR SPACE TEMPERATURE SENSOR SLIDE ADJUST AI7==SUCTION AI7 = SPACE TEMPERATURE SENSOR SLIDE ADJUST OR VOLTAGE RESET SOURCE VOLTAGE RESET SOURCE A01 =OR ECONOMIZER (2-10 VDC OUTPUT) A01 = ECONOMIZER (2-10 VDC OUTPUT) A02 = SUPPLY FAN VFD (0-10 VDC OUTPUT) A02 = SUPPLY FAN VFD (0-10 VDC OUTPUT) E-BUS CONNECTOR OE217-00 / OE217-01 Wall Mounted Digital Room Sensor ANALOGINPUT INPUT ANALOG JUMPER JUMPER SETTINGS SETTINGS STATUS1 STATUS2 0 1 SAT FAIL 1 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V OAT FAIL 2 2 SPC FAIL 3 2 MODULE ALARM 4 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V MECH COOL FAIL 1 AI4 AI4 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI5 AI5 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI2 AI2 AI3 AI3 TSDRSC Cable LED BLINK CODES NORMAL OPERATION AI1 AI1 ALARM AI7 AI7 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V 2 2 3 MECH HEAT FAIL 2 3 FAN PROOF FAIL 3 3 DIRTY FILTER 4 3 EMERGENCY SHUTDOWN 5 3 LOW SAT 1 4 HIGH SAT 2 4 CONT. TEMP COOL FAIL 3 4 CONT. TEMP HEAT FAIL 4 4 PUSH BUTTON OVR 1 5 2 5 OUTPUT FORCE ACTIVE 0 6 24 24 VAC POWER ONLY VAC POWER ONLY WARNING! POLARITY MUST BEBE OBSERVED WARNING! POLARITY MUST OBSERVED OR THE CONTROLLER WILL BEBE DAMAGED OR THE CONTROLLER WILL DAMAGED 2 2 STATIC WattMasterLabel Label ICIC WattMaster STATIC #LB102073-01-A EXPANSION PRESSURE PRESSURE #LB102033-01 EXPANSION Rev.: 1A POLARITY ZONE OVR WARNING OBSERVE THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V LED NAME ANALOG ANALOGINPUT INPUTJUMPER JUMPERSETTINGS SETTINGS MUST MUSTBE BESET SETAS ASSHOWN SHOWNFOR FOR PROPER PROPEROPERATION OPERATION Override Connection Of Wall Mounted Digital Room Sensor (When Used) AAON No.: VCM-X MODULAR E-BUS CONTROLLER V07150 Orion No.:OE332-23E-VCMX-MOD-A OE332-23-VCMX-A VCM-X CONTROLLER OE256-02 Duct Mounted CO2 Sensor Display FAN RELAY 2 RELAY 2 RELAY 3 RELAY 3 RELAY 4 RELAY 4 RELAY 5 RELAY 5 www.orioncontrols.com 2.) In This Configuration, Set The CO2 Sensor To Address 1. OVERRIDE RELAY CONTACT RATING IS 1 AMP RELAY CONTACT MAX @ VAC RATING IS24 1 AMP MAX @ 24 VAC RELAY COMMON RELAY COMMON FAN 2 2 IC IC DIGITAL DIGITAL SENSOR SENSOR TSDRSC Cable JOB NAME REVISED: 05/12/15 FILENAME O-VCM-X-DuctCO2-1A.CDR DATE: 01/09/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller 1 of 1 Duct-Mounted CO2 Sensor Figure 16: OE256-02 Duct-Mounted CO2 Sensor VCM-X Component & Systems Wiring 35 Zone VCM-X E-BUS Controller Wiring Zone Space Temperature Sensor & Remote Supply Air Reset Wiring Note: Either The Slide Offset Option For The Space Temperature Sensor Or The Remote Supply Air Temperature Reset Signal Option (By Others) May Be Connected To An AI7 On The VCM-X E-BUS Controller. Only One Option Is Allowed, Not Both. AI1 SET AI1 AI1 AI2 AI3 AI7 SET AUX AI7 SET AI5 SET OVR AI7 GND Set Jumper For THERM When Space Sensor Slide Adjust Is Wired To AI7 AI4 SET TMP W A R M E R C O O L E R AI5 AI3 SET AI4 AI7 GND AI2 SET OE210, OE211, OE212, OE213 Space Temperature Sensor Wire Required For Sensors With Slide Adjust Option Only VCM-X E-BUS Controller JOB NAME FILENAME O-VCM-X-SpaceSensor-1A.CDR DATE: 01/09/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller 1 of 1 Space Temperature Sensor Figure 17: OE210, OE211, OE212, OE213 Space Temperature Sensor Wiring Remote Supply Air Temperature Reset Signal (By Others) AI1 SET 0-5 VDC or 0-10 VDC Signal AI5 AI4 SET AI7 AI3 SET AI4 AI7 GND AI2 SET AI2 AI3 AI7 SET AI7 SET AI5 SET Note: Either The Slide Offset Option For The Space Temperature Sensor Or The Remote Supply Air Temperature Reset Signal Option (By Others) May Be Connected To AI7 On The VCM-X E-BUS Controller. Only One Option Is Allowed, Not Both. Regardless of Whether the Remote SAT Reset Signal Has Been Configured For 0-5 or 0-10 VDC, Jumper Must Be Set For 0-10V AI1 GND VCM-X E-BUS Controller JOB NAME FILENAME O-VCM-X-RemoteReset-1A.CDR DATE: 01/09/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller 1 of 1 Remote Reset Figure 18: Remote Supply Air Reset Wiring 36 VCM-X Component & Systems Wiring VCM-X E-BUS Controller Wiring Supply Air, Return Air, and Outdoor Air Temperature Sensor Wiring OE231 Supply Air Temperature Sensor AI1 SET AI1 AI2 AI3 AI2 AI3 AI5 AI7 AI4 SET AI5 SET OE231 Return Air Temperature Sensor AI3 SET AI4 GND GND AI2 SET Mount In HVAC Unit Supply Air Duct Be Sure The Jumper Is Set For THERM On AI2 & AI3 For Supply & Return Air Temperature Sensors When Used AI7 SET Mount In HVAC Unit Return Air Duct JOB NAME VCM-X E-BUS Controller FILENAME O-VCM-X-SAT&RA-1A.CDR DATE: 01/09/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller 1 of 1 Supply Air Temperature and Return Air Sensors Figure 19: OE231 Supply Air Temperature Sensor & OE231 Return Air Temperature Sensor Wiring OE250 Outdoor Air Temperature Sensor AI1 SET Make Splice Connections Inside Sensor Enclosure As Shown. Seal All Conduit Fittings With Silicone Sealant AI1 AI3 AI4 AI5 AI4 SET GND AI7 AI3 SET AI4 AI2 SET AI2 Be Sure Jumper Is Set For THERM On AI4 For Outdoor Air Temperature Sensor AI5 SET AI7 SET Mount Sensor Outdoors In Shaded Protected Area & In Upright Position As Shown JOB NAME For MUA Applications With A Heat Wheel, Mount Sensor Downstream Of The Heat Wheel REVISED: 05/12/15 FILENAME VCM-X E-BUS Controller O-VCM-X-OAT-1A.CDR DATE: 01/09/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller 1 of 1 Outdoor Air Sensor Figure 20: OE250 Outdoor Air Temperature Wiring VCM-X Component & Systems Wiring 37 Zone VCM-X E-BUS Controller Wiring Zone Economizer Damper Actuator Wiring AI3 AI4 AI5 COM - 1 GND AI5 SET + 2 Economizer Feedback 5 NOTE: For Economizer Actuator Feedback Signal, See AI3 Wiring For The VCM-X Expansion Module. AI7 SET Y1 3 AI4 SET AI7 AI3 SET 24 VAC GND AI1 AI2 AI2 SET Economizer Damper Actuator (Belimo Actuator Shown) AI1 SET Belimo Actuator Wiring Shown. Consult Factory For Other Manufacturer Wiring Instructions 24 VAC Power Source Sized For Actuator VA Load AO1 2-10 VDC Output VCM-X E-BUS Controller JOB NAME DATE: 05/12/15 S. Olson FILENAME O-VCM-X-Economizer-1B.CDR DATE: 01/09/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller 1 of 1 Economizer Actuator Figure 21: Economizer Damper Actuator Wiring 38 VCM-X Component & Systems Wiring VCM-X E-BUS Controller Wiring Supply Fan VFD & Bypass Damper Actuator Note: Either The Supply Fan VFD Or The Bypass Damper Actuator May Be Connected To AO2 On The VCM-X E-BUS Controller. Only One Option Is Allowed, Not Both. Caution: The VFD Unit Must Be Configured For 0-10 VDC Input. The Input Resistance At The VFD Must Not Be Less Than 1000 Ohms When Measured At The VFD Terminals With All Input Wires Removed. AI1 SET AI1 AI3 _ AI5 AI7 AI5 SET Supply Fan Variable Frequency Drive (By Others) AI4 SET GND Shield AI3 SET AI4 AI2 SET + AI2 0-10VDC Input From AO2 AI7 SET AO2 GND Shield Note: Wire To The VFD Using 18 GA Minimum 2 Conductor Twisted Pair With Shield Cable. Wire Shield To GND As Shown 24 VAC Power Source Sized For Actuator VA Load AI1 SET Note: Either The Supply Fan VFD Or The Bypass Damper Actuator May Be Connected To AO2 On The VCM-X E-BUS Controller. Only One Option Is Allowed, Not Both. VCM-X E-BUS Controller AI1 AI3 AI5 2 (+) 3 (Y) GND 24 VAC AI7 SET 1 (-) AI5 SET Bypass Damper Actuator (Belimo Actuator Shown) AI4 SET AI7 AI3 SET AI4 AI2 SET AI2 AO2 GND 0-10 VDC 5 (U) VCM-X E-BUS Controller Belimo Actuator Wiring Shown. Consult Factory For Other Manufacturer Wiring Instructions JOB NAME FILENAME OVCMX-ZoneByp-SFVFD-Wr1A.CDR DATE: 01/09/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Controller Wiring Detail 1 of 1 Supply Fan VFD or Bypass Damper Actuator Figure 22: Supply Fan VFD & Bypass Damper Actuator Wiring VCM-X Component & Systems Wiring 39 VCM-X E-BUS Controller Wiring 40 Zone Zone VCM-X Component & Systems Wiring VCM-X Expansion Module Wiring VCM-X Expansion, 4 Binary Input & 12-Relay Expansion Module Wiring VCM-X Component & Systems Wiring 41 VCM-X Expansion Module Wiring Input Wiring WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 24 VAC 10 VA Minimum Power Required For VCM-X Expansion Module GND Connect PR OUT To AI5 & GND To GND On VCM-X Controller When Either Suction Pressure Transducer Is Used VCM-X Expansion Module RD +V WH SIG BK GND Building Pressure Transducer + OUT COM + + EXC - LOW HIGH Emergency Shutdown - N.C. Contact Dirty Filter - N.O. Contact Plastic Tubing To Building Pressure Sensing Locations Proof Of Flow - N.O. Contact Remote Forced Occupied - N.O. Contact Remote Forced Heating - N.O. Contact Remote Forced Cooling - N.O. Contact Hood On - N.O. Contact Remote Forced Dehumidification N.O. Contact Economizer Damper Actuator (Belimo Actuator Shown) + 2 RELAY CONTACT PR OUT TO VCM-X INPUT RATING IS 1 AMP RELAY CONTACT GND TERMINALS AI5 & GND PR OUT TO VCM-X VCM-X INPUT OE333-23-EM-A EXPANSION MODULE MAX @ IS 241VAC RATING AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY 1 RELAY CONTACT PR OUT TO VCM-X INPUT RATING IS 11AMP RELAY GND TERMINALS AI5 & GND RELAY 2 SUCTION PRESSURE MAX @ 24 VAC +V SUCTION PRESSURE +V RELAY 2 TRANSDUCER SIG TRANSDUCERCONNECTION CONNECTION SIG FOR RELAY 1 3 RELAY GND FORHVAC HVACUNITS UNITSWITHOUT WITHOUT GND DIGITAL RELAY 3 DIGITALCOMPRESSOR COMPRESSOR RELAY 2 RELAY 4 SUCTION PRESSURE +V TRANSDUCER CONNECTION RELAY 4 SIG RELAY RELAY 3 FOR HVAC UNITS WITHOUT GND COMMON RELAY DIGITAL COMPRESSOR COMMON RELAY 4 BI1 BI 2 BI3 Y1 3 RELAY RELAY11== RELAY RELAY33== RELAY RELAY22== RELAY RELAY44== RELAY 1= ITIT IS ISSUGGESTED SUGGESTED THAT THATYOU YOUWRITE WRITETHE THE DESCRIPTION OF DESCRIPTION RELAY 2OUTPUTS = OF THE THERELAY RELAY OUTPUTS YOU YOUARE AREUSING USINGIN IN THE BOXES THE IT IS BOXES SUGGESTED PROVIDED PROVIDED ABOVETHE THAT YOU ABOVE WRITE WITH AAPERMANENT WITH PERMANENT DESCRIPTION OF MARKER (SHARPIE®) MARKER (SHARPIE®) THE RELAY OUTPUTS BI4 BI5 BI6 BI7 BI8 YOU ARE USING IN THE BOXES PROVIDED ABOVE ANALOG INPUT WITH A PERMANENT ANALOG INPUT MARKERSETTINGS (SHARPIE®) JUMPER JUMPER SETTINGS MUST MUSTBE BESET SETAS AS SHOWN SHOWNFOR FOR PROPER PROPER ANALOG INPUT OPERATION OPERATION JUMPER SETTINGS MUST BE SET AS SHOWN FOR ANALOG INPUT ANALOG INPUT PROPER JUMPER JUMPER OPERATION SETTINGS SETTINGS THERM THERM ANALOG INPUT 4-20mA 4-20mA AI1 AI1 JUMPER 0-10V 0-10V SETTINGS 0-5V 0-5V AI1 AI2 AI3 AI4 GND GND See Economizer Actuator Wiring AO1 For VCM-X Controller 1 VCM-X Expansion Module AAON No.: VCM-X Module AAON No.: Orion Expansion No.:OE333-23-EM R69190 Orion No.:OE333-23-EMwww.orioncontrols.com R69190 PR OUT GND Suction Pressure Transducer COM - 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION WARNING! EXPANSION #LB102034-01 OBSERVED OR THE BOARD POLARITY WILL BE BE DAMAGED MUST OBSERVED OR THE BOARD www.aaon.com www.orioncontrols.com www.aaon.com WILL BE www.orioncontrols.com DAMAGED POLARITY WARNING OBSERVE Note: 1.) If Unit Has Dehumidification Option And Copeland Digital Compressor Is Not Used, Wire Suction Pressure Transducer Directly To VCM-X Expansion Module As Shown. AI2 AI1 AI2 THERM THERM THERM 4-20mA 4-20mA 4-20mA 0-10V 0-10V 0-10V 0-5V 0-5V 0-5V AI2 AI3 AI3 THERM THERM THERM 4-20mA 4-20mA 4-20mA 0-10V 0-10V 0-10V 0-5V 0-5V 0-5V RELAY COMMON VCM RELAY 3 = BI1 BI1==EMERGENCY EMERGENCYSHUTDOWN SHUTDOWN- -N.C. N.C.INPUT INPUT BI2 - -N.O. INPUT DIRTYFILTER FILTER N.O. BI2==DIRTY RELAY 4 = INPUT BI3 PROOFOF OFFLOW FLOW- -N.O. N.O.INPUT INPUT BI3==PROOF BI4 REMOTEFORCED FORCEDOCCUPIED OCCUPIED- -N.O. N.O.INPUT INPUT BI4==REMOTE BI5 REMOTE HEATING BI1 ON FORCED - FORCED N.O. INPUT REMOTE HEATING- -N.O. N.O.INPUT INPUT BI5===HOOD BI6 REMOTE FORCED FILTER - N.O. COOLING INPUT BI2 REMOTE FORCED COOLING- -N.O. N.O.INPUT INPUT BI6===DIRTY BI7 HOOD - -N.O. OF N.O. INPUT BI3 HOODON ONFLOW N.O.-INPUT INPUT BI7===PROOF BI8 = REMOTE DEHUMIDIFICATION N.O. INPUT = REMOTE FORCED OCCUPIED N.O. INPUT BI4 BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT BI5 = REMOTE FORCED HEATING - N.O. INPUT = REMOTE FORCED COOLING - N.O. INPUT BI6 NOTE: NOTE: =BINARY SMOKE INPUTS DETECTOR - N.C. BI7 ALL BE 24 ALL BINARY INPUTSMUST MUST BEINPUT 24VAC VACONLY. ONLY. BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT AO1 NOTE: AO1==BUILDING BUILDINGPRESSURE PRESSURECONTROL CONTROLVFD VFDOR OR DAMPER ACTUATOR OR 2-10 ALL BINARY INPUTS MUST BE(0-10 24 VAC DAMPER ACTUATOR (0-10 ORONLY. 2-10VDC) VDC) AO2 AO2==MODULATING MODULATINGHEATING HEATINGSIGNAL SIGNAL (0-10 (0-10VDC VDCOR OR2-10 2-10VDC) VDC) AO1 PRESSURE CONTROL VFD OR AO3 MODULATING COOLING/DIGITAL SCROLL AO3===BUILDING MODULATING COOLING/DIGITAL SCROLL DAMPER ACTUATOR (0-10VDC VDC) VDC) SIGNAL OR SIGNAL(0-10 (0-10VDC, VDC,2-10 2-10 OR VDC2-10 OR1.5-5 1.5-5 VDC) AO2 == MODULATING HEATING SIGNAL AO4 RETURN AIR DAMPER ACTUATOR AO4 = RETURN AIR DAMPER ACTUATOR (0-10 VDC OR 2-10 VDC) (0-10 (0-10VDC) VDC) AO3 = MODULATING COOLING/DIGITAL SCROLL AO5 AO5==RETURN RETURNAIR AIRBYPASS BYPASSDAMPER DAMPERACTUATOR ACTUATOR SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 (0-10VDC) VDC) AO4 = RETURN AIR DAMPER ACTUATOR GND FOR GND=(0-10 =GROUND GROUND FORANALOG ANALOGOUTPUTS OUTPUTS VDC) FOR ANALOG OUTPUTS GND = GROUND GND GROUND ANALOG OUTPUTS AO5 == RETURN AIRFOR BYPASS DAMPER ACTUATOR (0-10 VDC) GND GROUND FOR OUTPUTS AI1 AIR RH (0-5 AI1== =OUTDOOR OUTDOOR AIRANALOG RHSENSOR SENSOR (0-5VDC) VDC) GND GROUND FOR ANALOG OUTPUTS AI2 RH SENSOR (0-5 =INDOOR INDOORAIR AIR RH SENSOR (0-5VDC) VDC) AI2== A3 II ==ECONOMIZER A3 ECONOMIZERFEEDBACK FEEDBACK AI4 BUILDING STATIC PRESSURE (0-5 THERM THERM AI4===OUTDOOR BUILDINGAIR STATIC PRESSURE (0-5VDC) VDC) THERM AI1 RHANALOG SENSOR (0-5 VDC) 4-20mA 4-20mA GND ==GROUND FOR INPUTS 4-20mA AI3 GND GROUND FOR ANALOG INPUTS AI4 = INDOOR AIR RH SENSOR (0-5 VDC) AI2 0-10V AI4 0-10V 0-10V GND ==GROUND FOR GROUND FORANALOG ANALOGINPUTS INPUTS GND 0-5V 0-5V = CO2 (0-10 VDC) AI3 0-5V AI4 = BUILDING STATIC PRESSURE (0-5 VDC) THERM 4-20mA GND = GROUND FOR ANALOG INPUTS AI4 0-10V ONLY WattMaster 24 VACI2C POWER I2C ANALOG FOR INPUTS GND = GROUNDI2C WattMaster Label Label 0-5V #LB102034-01-A I2C WARNING! POLARITY MUST BE Economizer Feedback 5 Outdoor Air Humidity Sensor EXPANSION OBSERVED OR THE BOARD WILL BE DAMAGED EXPANSION #LB102034-01-A EXPANSION EXPANSION Rev.: 1KRev.: 1L VAC OR DC GND 0-5V Indoor Air Humidity Sensor Modular Cable Connect To VCM-X E-BUS Controller VIN GND VOUT (0-5V) Modular Cable Connect To Next Expansion Board (When Used) Note: 1.) If Unit Has Dehumidification Option And Copeland Digital Compressor Is Used, Wire Suction Pressure Transducer To Copeland Controller As Shown. 2.) The Modulating Cooling Output Voltage Must Be Configured For 1.5 - 5 VDC Operation When You Are Setting Up The VCM-X Controller Operating Parameters. Copeland Digital Compressor Controller Suction Pressure Transducer P4 SHLD P5 P3 EXC P6 WH P2 OUT C1 BK P1 COM C2 RD JOB NAME REVISED: 05/12/15 S. Olson FILENAME OVCMX-Exp-Inputs-1A.CDR DATE: 01/11/13 PAGE S. Olson DESCRIPTION: VCM-X Expansion Module 1 of 1 Input Wiring Figure 23: OE333-23-EM - VCM-X Expansion Module Input Wiring 42 VCM-X Component & Systems Wiring VCM-X Expansion Module Wiring Output Wiring WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to-24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 24 VAC GND POLARITY WARNING OBSERVE 10 VA Minimum Power Required For VCM-X Expansion Module Relay Output Contacts R1 Through R4 May Be User-Configured For The Following: 1 - Heating Stages 2 - Cooling Stages 3 - Warm-up Mode Command (VAV Boxes) 4 - Reversing Valve (Heat Pumps) 5 - Reheat Control (Dehumidification) 6 - Exhaust Fan Interlock 7 - Preheater For Low Ambient Protection 8 - Alarm 9 - Override 10 - Occupied 11 - OA Damper 12 - Heat Wheel 13 - Emergency Heat Note: A Total Of 20 Relays Are Available By Adding Relay Expansion Modules. All Expansion Module Relay Outputs Are UserConfigurable As Listed Above. Note: All Relay Outputs Are Normally Open And Rated For 24 VAC Power Only. 1 Amp Maximum Load. 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION EXPANSION WARNING! #LB102034-01 OBSERVED OR THE BOARD POLARITY WILL BE BE DAMAGED MUST OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED VCM-X Expansion Module AAON No.: Orion No.:OE333-23-EMwww.orioncontrols.com R69190 R1 R2 R3 R4 RELAY CONTACT PROE333-23-EM-A OUT TO VCM-X VCM-X INPUT EXPANSION MODULE RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RATING IS 11AMP RELAY GND TERMINALS AI5 & GND MAX @ 24 VAC SUCTION PRESSURE +V RELAY 2 TRANSDUCER CONNECTION SIG FOR HVAC UNITS WITHOUT RELAY 1 GND DIGITAL COMPRESSOR RELAY 3 RELAY 2 SUCTION PRESSURE +V TRANSDUCER CONNECTION RELAY 4 SIG RELAY 3 FOR HVAC UNITS WITHOUT GND DIGITAL COMPRESSOR RELAY RELAY 4 COMMON RELAY 1 = RELAY 3 = RELAY 2 = RELAY 4 = 1= ITRELAY IS SUGGESTED THAT YOU WRITE THE DESCRIPTION OF RELAY 2 = THE RELAY OUTPUTS YOU ARE USING IN THE IT ISBOXES SUGGESTED PROVIDED THAT YOU ABOVE WRITE THE WITH A PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS YOU ARE USING IN THE BOXES PROVIDED ABOVE WITH A PERMANENT ANALOG INPUT MARKER (SHARPIE®) JUMPER SETTINGS THERM ANALOG INPUT 4-20mA SETTINGS 0-5V AI1 AI2 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI2 AI3 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI3 AI4 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI4 THERM 4-20mA 0-10V 0-5V I2C EXPANSION Building Pressure Relief Fan VFD + COM Note: 1.) The Modulating Cooling Device Used Must Be Capable Of Accepting Either A 0-10 VDC, 2-10 VDC or 1.55.0 VDC Input. The Modulating Cooling Output Voltage Is User Configurable For These Voltages. The Modulating Heating Devices Used Must Be Capable of Accepting Either A 0-10 VDC or 210 VDC Input. The Modulating Heating Output Voltage Is UserConfigurable For These Voltages. These Voltage Outputs Must Also Be Configured When You Are Setting Up The VCM-X Controller(s) Operating Parameters. COM Modulating Cooling Or Digital Scroll Compressor (1.5 To 5, 0 To 10 Or 2 To 10 VDC Input) + When Copeland Digital Compressor Is Used, Wire Per Copeland Digital Compressor Wiring Detail AO1 AO2 AO3 AO4 COM Return Air Damper Actuator (0-10 VDC) AO5 GND 1 COM GND 2 + 3 Y1 Return Air Bypass Damper Actuator (0-10 VDC) 2.) Each Modulating Heating Or Cooling Device Used On The VCM-X Controller Must Have (1) Relay Output Configured For Each Device Used, In Order To Enable The Modulating Heating And/Or Cooling Device's Sequence. This Relay Output Must Be Configured When Setting Up The VCM-X Controller Operating Parameters. 1 COM 2 + 3 Y1 Belimo Actuator Wiring Shown. Consult Factory For Other Manufacturer Wiring Instructions Modular Cable Connect To VCM-X E-BUS Controller Note: 1.) If Unit Has Dehumidification Option And Copeland Digital Compressor Is Used, Wire Suction Pressure Transducer To Copeland Controller As Shown. Modular Cable Connect To Next Expansion Board (When Used) Copeland Digital Compressor Controller RD 2 + 3 Y1 VCM SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) AO2 RETURN AIR HEATING DAMPERSIGNAL ACTUATOR AO4==MODULATING (0-10 OR 2-10 VDC) (0-10VDC VDC) AO3 RETURN AIR COOLING/DIGITAL BYPASS DAMPERSCROLL ACTUATOR AO5==MODULATING SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 VDC) AO4 = RETURN AIR DAMPER ACTUATOR GND = GROUND FOR ANALOG OUTPUTS (0-10 VDC) GND = GROUND FOR ANALOG OUTPUTS AO5 = RETURN AIR BYPASS DAMPER ACTUATOR (0-10 VDC) GND GROUND FOR OUTPUTS AI1 == OUTDOOR AIRANALOG RH SENSOR (0-5 VDC) GND GROUNDAIR FORRH ANALOG OUTPUTS AI2 == INDOOR SENSOR (0-5 VDC) A3I = ECONOMIZER FEEDBACK AI4==OUTDOOR BUILDINGAIR STATIC PRESSURE (0-5 VDC) AI1 RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI2 = INDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI3 = CO2 (0-10 VDC) AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label GND = GROUND FOR I2C ANALOG INPUTS #LB102034-01-A EXPANSION Rev.: 1L Suction Pressure Transducer 1 COM + RELAY COMMON RELAY 3= BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT BI3 = PROOF OFRELAY FLOW4 -=N.O. INPUT BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT BI1 ON -FORCED N.O. INPUT BI5 ==HOOD REMOTE HEATING - N.O. INPUT FILTER - N.O. INPUT BI2 BI6 ==DIRTY REMOTE FORCED COOLING - N.O. INPUT OF FLOW N.O. INPUT BI3 BI7 ==PROOF HOOD ON - N.O. -INPUT OCCUPIED - N.O. INPUT BI4 BI8 ==REMOTE REMOTEFORCED DEHUMIDIFICATION - N.O. INPUT BI5 = REMOTE FORCED HEATING - N.O. INPUT = REMOTE FORCED COOLING - N.O. INPUT BI6 NOTE: BI7 SMOKE INPUTS DETECTOR - N.C. ALL=BINARY MUST BEINPUT 24 VAC ONLY. BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT VCM-X Expansion Module Configurable Relay Output #1 Configurable Relay Output #2 Configurable Relay Output #3 Configurable Relay Output #4 Building Pressure Control Damper Actuator Modulating Heating (0 to 10 VDC Input) MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT NOTE: AO1 = BUILDING PRESSURE CONTROL VFD OR OPERATION JUMPER SETTINGS ALL BINARY INPUTS MUST BE 24 VAC ONLY. DAMPER ACTUATOR (0-10 OR 2-10 VDC) MUST BE SET AS AO2 = MODULATING HEATING SIGNAL SHOWN FOR ANALOG INPUT PROPER (0-10 VDC OR 2-10 VDC) JUMPER AO1 = PRESSURE CONTROL VFD OR OPERATION MODULATING COOLING/DIGITAL SCROLL AO3 =BUILDING SETTINGS DAMPER ACTUATOR (0-10 OR 2-10 VDC) AI1 JUMPER 0-10V Either A Building Pressure Damper Actuator Or a Building Pressure Relief Fan VFD Can Be Used, P4 SHLD P5 P3 EXC P6 WH P2 OUT C1 BK P1 COM C2 2.) The Modulating Cooling Output Voltage Must Be Configured For 1.5 - 5 VDC Operation When You Are Setting Up The VCM-X Controller Operating Parameters For The Copeland Digital Compressor. JOB NAME S. Olson REVISED: 05/14/15 Copeland Digital Compressor Wiring Detail FILENAME VCMX-Exp-Outputs-1B.CDR DATE: 01/11/13 PAGE S. Olson DESCRIPTION: VCM-X Expansion Module 1 of 1 Output Wiring Figure 24: OE333-23-EM - VCM-X Expansion Module Output Wiring VCM-X Component & Systems Wiring 43 VCM-X Expansion Module Wiring Suction Pressure Transducer Without Digital Compressor To VCM-X Expansion Module As Shown. OE275-01 Suction Pressure WARNING OBSERVE Note: 1.) If Unit Has Dehumidification Option And Copeland Digital Compressor Is Not Used, Wire Suction Pressure Transducer Directly Connect PR OUT To AI5 & GND To GND On VCM-X Controller When The Suction Pressure Transducer Is Used PR OUT GND RD WH BK POLARITY WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to-24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 10 VA Minimum Power Required For VCM-X Expansion Module 24 VAC GND 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION WARNING! EXPANSION #LB102034-01 OBSERVED OR THE BOARD POLARITY WILLBE BE DAMAGED MUST OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED VCM-X Expansion Module AAON No.: Orion No.:OE333-23-EMwww.orioncontrols.com R69190 RELAY CONTACT PR OE333-23-EM-A OUT TO VCM-X VCM-X INPUT EXPANSION MODULE RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RELAY RATING IS 1 1 AMP GND TERMINALS AI5 & GND SUCTION PRESSURE +V MAX @ 24 VAC RELAY 2 TRANSDUCER CONNECTION SIG FOR HVAC UNITS WITHOUT GND RELAY 1 DIGITAL COMPRESSOR RELAY 3 RELAY 2 SUCTION PRESSURE +V RELAY 4 TRANSDUCER CONNECTION SIG RELAY 3 FOR HVAC UNITS WITHOUT GND RELAY DIGITAL COMPRESSOR COMMON RELAY 4 +V SIG GND Caution: 1.) The Schraeder Port Used For Installation Of The Suction Pressure Transducer Should Be Located In A Vertical Portion Of The Suction Line To Prevent Refrigerant Oil From Accumulating In The Sensor. RELAY 1 = RELAY 3 = RELAY 2 = RELAY 4 = IT RELAY IS SUGGESTED 1= THAT YOU WRITE THE DESCRIPTION OF RELAY = THE RELAY2OUTPUTS YOU ARE USING IN THE BOXES IT IS SUGGESTED PROVIDED ABOVE THATAYOU WRITE THE WITH PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS YOU ARE USING IN THE BOXES PROVIDED ABOVE ANALOG INPUT WITH A PERMANENT JUMPER MARKERSETTINGS (SHARPIE®) MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT OPERATION JUMPER SETTINGS MUST BE SET AS SHOWN FOR ANALOG INPUT PROPER JUMPER OPERATION SETTINGS Note: 1.) If Unit Has Dehumidification Option And Copeland Digital Compressor Is Used, Wire Suction Pressure Transducer To Copeland Controller As Shown On Following Page. THERM 4-20mA ANALOG INPUT AI1 0-10V JUMPER 0-5V SETTINGS AI2 AI1 AI3 AI2 AI4 AI3 2.) AO3 Output Voltage Must Be Configured For 1.5 - 5 VDC Operation When You Are Setting Up The VCM-X Controller Operating Parameters For A Copeland Digital Compressor. THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V THERM 4-20mA AI4 I2C 0-10V 0-5V EXPANSION RELAY COMMON VCM RELAY 3= BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT BI3 = PROOF OFRELAY FLOW4 -=N.O. INPUT BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT BI5 == HOOD REMOTE HEATING - N.O. INPUT BI1 ON -FORCED N.O. INPUT BI6 == DIRTY REMOTE FORCED COOLING - N.O. INPUT FILTER - N.O. INPUT BI2 BI7 == PROOF HOOD ON - N.O. -INPUT OF FLOW N.O. INPUT BI3 BI8 == REMOTE REMOTEFORCED DEHUMIDIFICATION - N.O. INPUT OCCUPIED - N.O. INPUT BI4 BI5 = REMOTE FORCED HEATING - N.O. INPUT NOTE: = REMOTE FORCED COOLING - N.O. INPUT BI6 ALL=BINARY MUST BEINPUT 24 VAC ONLY. SMOKE INPUTS DETECTOR - N.C. BI7 BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT AO1 = BUILDING PRESSURE CONTROL VFD OR NOTE: DAMPER ACTUATOR ORONLY. 2-10 VDC) ALL BINARY INPUTS MUST BE(0-10 24 VAC AO2 = MODULATING HEATING SIGNAL (0-10 VDC OR 2-10 VDC) AO3 MODULATING COOLING/DIGITAL SCROLL AO1 == BUILDING PRESSURE CONTROL VFD OR SIGNAL (0-10 VDC, (0-10 2-10 VDC ORVDC) 1.5-5 VDC) DAMPER ACTUATOR OR 2-10 AO4 ==MODULATING RETURN AIR HEATING DAMPERSIGNAL ACTUATOR AO2 (0-10VDC VDC) (0-10 OR 2-10 VDC) AO5 ==MODULATING RETURN AIR COOLING/DIGITAL BYPASS DAMPERSCROLL ACTUATOR AO3 (0-10 VDC) SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) GND==RETURN GROUND ANALOG OUTPUTS AO4 AIRFOR DAMPER ACTUATOR GND =(0-10 GROUND VDC) FOR ANALOG OUTPUTS AO5 = RETURN AIR BYPASS DAMPER ACTUATOR (0-10 VDC) AI1 = OUTDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG OUTPUTS AI2 ==INDOOR SENSOR (0-5 VDC) GND GROUNDAIR FORRH ANALOG OUTPUTS A3 I = ECONOMIZER FEEDBACK AI4 = BUILDING STATIC PRESSURE (0-5 VDC) AI1 = OUTDOOR RHANALOG SENSOR INPUTS (0-5 VDC) GND = GROUNDAIR FOR = INDOOR AIR FOR RH SENSOR (0-5 VDC) AI2 GND = GROUND ANALOG INPUTS AI3 = CO2 (0-10 VDC) AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label I2C ANALOG INPUTS GND = GROUND FOR #LB102034-01-A EXPANSION Rev.: 1L VCM-X Expansion Module Modular Cable Connect To VCM-X E-BUS Controller Modular Cable Connect To Next Expansion Board(When Used) JOB NAME REVISED: 05/14/15 S. Olson FILENAME O-VCM-X-SuctP-WO-DigC-1B.CDR DATE: 01/10/13 PAGE S. Olson DESCRIPTION: VCM-X E-BUS Expansion Module 1 of 1 Suction Pressure Transducer w/o Digital Comp. Figure 25: OE275-01 Suction Pressure Transducer Without Digital Compressor Wiring 44 VCM-X Component & Systems Wiring VCM-X Expansion Module Wiring Suction Pressure Transducer With Digital Compressor Figure 26: OE275-01 Suction Pressure Transducer With Digital Compressor Wiring VCM-X Component & Systems Wiring 45 VCM-X Expansion Module Wiring Expansion Module Binary Inputs WARNING OBSERVE 10 VA Minimum Power Required For VCM-X Expansion Module WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION WARNING! EXPANSION #LB102034-01 OBSERVED OR THE BOARD POLARITY WILLBE BE DAMAGED MUST OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED POLARITY 24 VAC GND VCM-X Expansion Module AAON No.: Orion No.:OE333-23-EMwww.orioncontrols.com R69190 RELAY CONTACT PR OE333-23-EM-A OUT TO VCM-X INPUT VCM-X EXPANSION MODULE RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RELAY RATING IS 11AMP GND TERMINALS AI5 & GND SUCTION PRESSURE MAX @ 24 VAC +V RELAY 2 TRANSDUCER CONNECTION SIG FOR HVAC UNITS WITHOUT RELAY 1 GND DIGITAL COMPRESSOR RELAY 3 RELAY 2 SUCTION PRESSURE +V TRANSDUCER CONNECTION RELAY 4 SIG RELAY 3 FOR HVAC UNITS WITHOUT GND RELAY DIGITAL COMPRESSOR COMMON RELAY 4 BI1 BI2 BI3 Proof Of Flow - N.O. Contact Remote Forced Occupied - N.O. Contact BI4 Remote Forced Heating - N.O. Contact BI5 Remote Forced Cooling - N.O. Contact BI6 Hood On - N.O. Contact BI7 Remote Forced Dehumidification BI8 Emergency Shutdown - N.C. Contact Dirty Filter - N.O. Contact RELAY 1 = RELAY 3 = RELAY 2 = RELAY 4 = IT RELAY IS SUGGESTED 1= THAT YOU WRITE THE DESCRIPTION OF RELAY = THE RELAY2OUTPUTS YOU ARE USING IN THE BOXES IT IS SUGGESTED PROVIDED ABOVE THAT YOU WRITE THE WITH A PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS YOU ARE USING IN THE BOXES PROVIDED ABOVE ANALOG INPUT WITH A PERMANENT JUMPER MARKERSETTINGS (SHARPIE®) MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT OPERATION JUMPER SETTINGS MUST BE SET AS SHOWN FOR ANALOG INPUT PROPER JUMPER OPERATION SETTINGS N.O. Contact THERM ANALOG 4-20mA INPUT JUMPER 0-10V SETTINGS 0-5V AI1 AI2 AI1 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI2 AI3 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI3 AI4 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI4 THERM 4-20mA I2C 0-10V 0-5V EXPANSION RELAY COMMON VCM RELAY 3= BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT BI3 = PROOF OFRELAY FLOW4- =N.O. INPUT BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT BI5 REMOTE HEATING - N.O. INPUT BI1 = HOOD ON FORCED - N.O. INPUT BI6 REMOTE FORCED - N.O. INPUT FILTER - N.O. COOLING INPUT BI2 = DIRTY BI7 HOOD ON N.O. INPUT OF -FLOW - N.O. INPUT BI3 = PROOF BI8 REMOTEFORCED DEHUMIDIFICATION - N.O. INPUT OCCUPIED - N.O. INPUT BI4 = REMOTE BI5 = REMOTE FORCED HEATING - N.O. INPUT BI6 = REMOTE FORCED COOLING - N.O. INPUT NOTE: SMOKEINPUTS DETECTOR - N.C. BI7 =BINARY ALL MUST BEINPUT 24 VAC ONLY. BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT AO1 = BUILDING PRESSURE CONTROL VFD OR NOTE: DAMPER ACTUATOR (0-10 OR ONLY. 2-10 VDC) ALL BINARY INPUTS MUST BE 24 VAC AO2 = MODULATING HEATING SIGNAL (0-10 VDC OR 2-10 VDC) AO1 = BUILDING PRESSURE CONTROL VFD OR AO3 MODULATING COOLING/DIGITAL SCROLL DAMPER ACTUATOR (0-10VDC OR 2-10 VDC) VDC) SIGNAL (0-10 VDC, 2-10 OR 1.5-5 AO2 = MODULATING HEATING SIGNAL RETURN AIR DAMPER ACTUATOR AO4 (0-10 VDC OR 2-10 VDC) (0-10 VDC) AO3 = COOLING/DIGITAL = MODULATING RETURN AIR BYPASS DAMPERSCROLL ACTUATOR AO5 SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 VDC) AO4 ==RETURN AIR DAMPER ACTUATOR GROUND FOR ANALOG OUTPUTS GND VDC) FOR ANALOG OUTPUTS GROUND GND =(0-10 AO5 = RETURN AIR BYPASS DAMPER ACTUATOR (0-10 VDC) AI1 AIR ANALOG RH SENSOR (0-5 VDC) GND==OUTDOOR GROUND FOR OUTPUTS GND==INDOOR GROUNDAIR FOR ANALOG OUTPUTS RH SENSOR (0-5 VDC) AI2 I = ECONOMIZER FEEDBACK A3 AI4 = BUILDING STATIC PRESSURE (0-5 VDC) AI1 = OUTDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI2 = INDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI3 = CO2 (0-10 VDC) AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label I2C ANALOG INPUTS GND = GROUND FOR #LB102034-01-A EXPANSION Rev.: 1L VCM-X Expansion Module Modular Cable Connect To VCM-X E-BUS Controller Modular Cable Connect To Next Expansion Board (When Used) JOB NAME FILENAME OVCMX-Exp-BinaryInputs1B.CDR DATE: PAGE 05/14/15 S. Olson DESCRIPTION: VCM-X Expansion Module 1 of 1 Binary Inputs Figure 27: VCM-X Expansion Module Binary Inputs Wiring 46 VCM-X Component & Systems Wiring VCM-X Expansion Module Wiring 4 Binary Input Expansion Module WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 5 VA Minimum Power Required For 4 Binary Input Expansion Module Modular Cable Connect To VCM-X E-BUS Controller Modular Cable Connect To Next Expansion Board (When Used) 24 VAC GND 24 VAC GND 24VAC GND OE356-00-BI 4 Binary Input Expansion Module VCM BIN EXP BOARD YS102364 REV1 PWR BI1 BI2 BI4 BI3 BI2 BI1 BI4 BI3 COM COM Emergency Shutdown - N.C. Contact Dirty Filter - N.O. Contact Proof Of Flow - N.O. Contact Remote Forced Occupied - N.O. Contact JOB NAME FILENAME OVCMX-BinInput-4BIN-1A.CDR DATE: 01/10/13 PAGE S. Olson DESCRIPTION: VCM-X Expansion Module 1 of 1 Binary Inputs On 4 Binary Input Module Figure 28: OE356-00-BI 4 Binary Input Expansion Module Wiring VCM-X Component & Systems Wiring 47 Zone VCM-X Expansion Module Wiring Zone Outdoor Air Humidity Sensor 24 VAC GND WARNING OBSERVE 10 VA Minimum Power Required For VCM-X Expansion Module OA Humidity Sensor POLARITY WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION WARNING! EXPANSION #LB102034-01 OBSERVED OR THE BOARD POLARITY WILLBE BE DAMAGED MUST OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED 4-20 mA VAC or DC GND 0-5V or 0-10V VCM-X Expansion Module AAON No.: Orion No.:OE333-23-EMwww.orioncontrols.com R69190 RELAY CONTACT PR OE333-23-EM-A OUT TO VCM-X INPUT VCM-X EXPANSION MODULE RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RELAY RATING IS 11AMP GND TERMINALS AI5 & GND SUCTION PRESSURE MAX @ 24 VAC +V RELAY 2 TRANSDUCER CONNECTION SIG FOR HVAC UNITS WITHOUT RELAY 1 GND DIGITAL COMPRESSOR RELAY 3 RELAY 2 SUCTION PRESSURE +V TRANSDUCER CONNECTION RELAY 4 SIG RELAY 3 FOR HVAC UNITS WITHOUT GND RELAY DIGITAL COMPRESSOR COMMON RELAY 4 Span Zero RELAY 1 = RELAY 3 = RELAY 2 = RELAY 4 = RELAY COMMON VCM 1 2 3 4 ON 1= IT RELAY IS SUGGESTED THAT YOU WRITE THE DESCRIPTION OF RELAY = THE RELAY2OUTPUTS YOU ARE USING IN THE BOXES IT IS SUGGESTED PROVIDED ABOVE THAT YOU WRITE THE WITH A PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS 1 YOU ARE USING IN THE BOXES PROVIDED ABOVE 2 3 4 5 6 ON ANALOG INPUT WITH A PERMANENT MARKERSETTINGS (SHARPIE®) JUMPER MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT OPERATION JUMPER SETTINGS MUST BE SET AS SHOWN FOR ANALOG INPUT PROPER JUMPER OPERATION SETTINGS THERM 1 AI1 ANALOG 4-20mA INPUT AI1 JUMPER 0-10V 2 3 4 SETTINGS 0-5V ON GND 1 2 3 4 5 6 ON Jumpers Must Be Set as Shown For Correct O-5 VDC Operation 1 & 3 Are Off 2 & 4 Are On Jumpers Must Be Set as Shown For Normal Operation Of Sensor 1, 2, 4, 5 & 6 Are Off 3 Is On Jumper Must Be Set To 0-5V As Shown AI2 AI1 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI2 AI3 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI3 AI4 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI4 THERM 4-20mA I2C 0-10V 0-5V EXPANSION RELAY 3= BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT BI3 = PROOF OFRELAY FLOW4- =N.O. INPUT BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT BI5 REMOTE HEATING - N.O. INPUT BI1 = HOOD ON FORCED - N.O. INPUT BI6 REMOTE FORCED - N.O. INPUT FILTER - N.O. COOLING INPUT BI2 = DIRTY BI7 HOOD ON N.O. INPUT OF -FLOW - N.O. INPUT BI3 = PROOF BI8 REMOTEFORCED DEHUMIDIFICATION - N.O. INPUT OCCUPIED - N.O. INPUT BI4 = REMOTE BI5 = REMOTE FORCED HEATING - N.O. INPUT BI6 = REMOTE FORCED COOLING - N.O. INPUT NOTE: BI7 =BINARY SMOKEINPUTS DETECTOR - N.C. ALL MUST BEINPUT 24 VAC ONLY. BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT AO1 = BUILDING PRESSURE CONTROL VFD OR NOTE: ALL BINARY INPUTS MUST BE 24 VAC DAMPER ACTUATOR (0-10 OR ONLY. 2-10 VDC) AO2 = MODULATING HEATING SIGNAL (0-10 VDC OR 2-10 VDC) AO1 = PRESSURE CONTROL VFD OR AO3 = BUILDING MODULATING COOLING/DIGITAL SCROLL DAMPER ACTUATOR (0-10 OR 2-10 VDC) VDC) SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 HEATING SIGNAL AO2 = AO4 = MODULATING RETURN AIR DAMPER ACTUATOR (0-10 (0-10VDC VDC)OR 2-10 VDC) = MODULATING COOLING/DIGITAL SCROLL AO3 AO5 = RETURN AIR BYPASS DAMPER ACTUATOR SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 VDC) AO4 ==RETURN AIR DAMPER ACTUATOR GND GROUND FOR ANALOG OUTPUTS VDC) FOR ANALOG OUTPUTS GND =(0-10 GROUND AO5 = RETURN AIR BYPASS DAMPER ACTUATOR (0-10 VDC) GND==OUTDOOR GROUND FOR OUTPUTS AI1 AIR ANALOG RH SENSOR (0-5 VDC) GND==INDOOR GROUNDAIR FOR ANALOG OUTPUTS AI2 RH SENSOR (0-5 VDC) A3 I = ECONOMIZER FEEDBACK AI4 = BUILDING STATIC PRESSURE (0-5 VDC) AI1 = OUTDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI2 = INDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI3 = CO2 (0-10 VDC) AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label GND = GROUND FOR I2C ANALOG INPUTS #LB102034-01-A EXPANSION Rev.: 1L VCM-X Expansion Module Modular Cable Connect To Next Expansion Board (When Used) Modular Cable Connect To VCM-X E-BUS Controller JOB NAME FILENAME OVCMX-OA-HumSensorWr-1B.CDR DATE: 05/14/15 PAGE B. Crews DESCRIPTION: VCM-X Expansion Module 1 of 1 Outdoor Air Humidity Sensor Figure 29: OE265-13 - Outdoor Air Humidity Sensor Wiring 48 VCM-X Component & Systems Wiring VCM-X E-BUS Controller Wiring Indoor Wall-Mounted Humidity Sensor WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to-24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 24 VAC GND POLARITY WARNING OBSERVE 10 VA Minimum Power Required For VCM-X Expansion Module Space Humidity Sensor VCM-X Expansion Module AAON No.: Orion No.:OE333-23-EMwww.orioncontrols.com R69190 RELAY CONTACT PR OE333-23-EM-A OUT TO VCM-X INPUT VCM-X EXPANSION MODULE RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RATING IS 11AMP RELAY GND TERMINALS AI5 & GND SUCTION PRESSURE MAX @ 24 VAC +V RELAY 2 TRANSDUCER CONNECTION SIG FOR HVAC UNITS WITHOUT RELAY 1 GND DIGITAL COMPRESSOR RELAY 3 RELAY 2 SUCTION PRESSURE +V Zero Span 3 4 Vo Gnd 2 Io 1 ON Vin 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION WARNING! EXPANSION #LB102034-01 OBSERVED OR THE BOARD POLARITY WILLBE BE DAMAGED MUST OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED TRANSDUCER CONNECTION FOR HVAC UNITS WITHOUT DIGITAL COMPRESSOR SIG GND RELAY 1 = RELAY 3 = RELAY 2 = RELAY 4 = 1= IT RELAY IS SUGGESTED THAT YOU WRITE THE DESCRIPTION OF RELAY 2 = THE RELAY OUTPUTS YOU ARE USING IN THE BOXES IT IS SUGGESTED PROVIDED THAT YOUABOVE WRITE THE WITH A PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS YOU ARE USING IN THE BOXES PROVIDED ABOVE WITH A PERMANENT ANALOG INPUT MARKERSETTINGS (SHARPIE®) JUMPER MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT OPERATION JUMPER SETTINGS MUST BE SET AS SHOWN FOR ANALOG INPUT PROPER JUMPER OPERATION SETTINGS 1 2 3 1 4 2 3 4 5 6 ON ON THERM ANALOG 4-20mA INPUT AI2 1 2 3 4 5 6 ON Jumpers Must Be Set as Shown For Normal Operation Of Sensor 1, 2, 4, 5 & 6 Are Off 3 Is On Jumpers Must Be Set as Shown For Correct O-5 VDC Operation 1 & 3 Are Off 2 & 4 Are On GND AI1 JUMPER 0-10V SETTINGS 0-5V AI1 AI2 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI2 AI3 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V THERM 4-20mA AI4 0-10V I2C 0-5V AI3 AI4 Jumper Must Be Set To 0-5V As Shown RELAY 4 RELAY 3 RELAY COMMON RELAY 4 EXPANSION RELAY COMMON VCM RELAY 3= BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT BI3 = PROOF OFRELAY FLOW4- =N.O. INPUT BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT BI1 = HOOD ON FORCED - N.O. INPUT BI5 REMOTE HEATING - N.O. INPUT BI2 = DIRTY FILTER - N.O. COOLING INPUT BI6 REMOTE FORCED - N.O. INPUT BI3 = PROOF OF -FLOW - N.O. INPUT BI7 HOOD ON N.O. INPUT BI4 = REMOTE OCCUPIED - N.O. INPUT BI8 REMOTEFORCED DEHUMIDIFICATION - N.O. INPUT BI5 = REMOTE FORCED HEATING - N.O. INPUT BI6 = REMOTE FORCED COOLING N.O. INPUT NOTE: BI7 =BINARY SMOKEINPUTS DETECTOR - N.C. ALL MUST BEINPUT 24 VAC ONLY. BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT NOTE: AO1 = BUILDING PRESSURE CONTROL VFD OR ALL BINARY INPUTS MUST BE 24 VAC DAMPER ACTUATOR (0-10 OR ONLY. 2-10 VDC) AO2 = MODULATING HEATING SIGNAL (0-10 VDC OR 2-10 VDC) AO1 = PRESSURE CONTROL VFD OR = BUILDING MODULATING COOLING/DIGITAL SCROLL AO3 DAMPER ACTUATOR (0-10 OR 2-10 VDC) VDC) SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 HEATING SIGNAL AO2 = = MODULATING RETURN AIR DAMPER ACTUATOR AO4 (0-10 VDC OR 2-10 VDC) (0-10 VDC) AO3 = MODULATING COOLING/DIGITAL SCROLL AO5 = RETURN AIR BYPASS DAMPER ACTUATOR SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 VDC) AO4 = RETURN AIR DAMPER ACTUATOR GND = GROUND FOR ANALOG OUTPUTS (0-10 VDC) GND GROUND FOR ANALOG OUTPUTS AIR BYPASS DAMPER ACTUATOR AO5 ==RETURN (0-10 VDC) GND==OUTDOOR GROUND FOR OUTPUTS AI1 AIR ANALOG RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG OUTPUTS AI2 = INDOOR AIR RH SENSOR (0-5 VDC) A3 I = ECONOMIZER FEEDBACK AI4 = OUTDOOR BUILDING AIR STATIC PRESSURE AI1 = RH SENSOR (0-5 (0-5 VDC)VDC) GND GROUND ANALOG(0-5 INPUTS AI2 = =INDOOR AIRFOR RH SENSOR VDC) GND GROUND FOR ANALOG INPUTS AI3 = =CO2 (0-10 VDC) AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label GND = GROUND FOR I2C ANALOG INPUTS #LB102034-01-A EXPANSION Rev.: 1L VCM-X Expansion Module Modular Cable Connect To Next Expansion Board (When Used) Modular Cable Connect To VCM-X E-BUS Controller JOB NAME DATE: 05/14/15 S. Olson FILENAME OVCMX-SPC-HumSensorWr-1B.CDR DATE: 01/11/13 PAGE B. Crews DESCRIPTION: VCM-X Expansion Module 1 of 1 Space Humidity Sensor Figure 30: OE265-11 - Indoor Wall Mounted Humidity Sensor Wiring VCM-X Component & Systems Wiring 49 VCM-X Expansion Module Wiring Return Air Humidity Sensor 24 VAC GND WARNING OBSERVE 10 VA Minimum Power Required For VCM-X Expansion Module RA Humidity Sensor POLARITY WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to-24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION WARNING! EXPANSION #LB102034-01 OBSERVED OR THE BOARD POLARITY WILL BE BE DAMAGED MUST OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED 4-20 mA VAC or DC GND 0-5V or 0-10V VCM-X Expansion Module AAON No.: Orion No.:OE333-23-EMwww.orioncontrols.com R69190 RELAY CONTACT PROE333-23-EM-A OUT TO VCM-X VCM-X INPUT EXPANSION MODULE RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RATING IS 1 1 AMP RELAY GND TERMINALS AI5 & GND SUCTION PRESSURE MAX @ 24 VAC +V RELAY 2 TRANSDUCER CONNECTION SIG FOR HVAC UNITS WITHOUT RELAY 1 GND DIGITAL COMPRESSOR RELAY 3 RELAY 2 SUCTION PRESSURE +V TRANSDUCER CONNECTION RELAY 4 SIG RELAY 3 FOR HVAC UNITS WITHOUT GND RELAY DIGITAL COMPRESSOR COMMON RELAY 4 Span Zero RELAY 1 = RELAY 3 = RELAY 2 = RELAY 4 = RELAY COMMON VCM 1 2 3 4 ON 1= ITRELAY IS SUGGESTED THAT YOU WRITE THE DESCRIPTION OF RELAY 2 OUTPUTS = THE RELAY YOU ARE USING IN THE IT ISBOXES SUGGESTED PROVIDED THAT YOU ABOVE WRITE THE WITH A PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS YOU ARE USING IN THE BOXES PROVIDED ABOVE ANALOG INPUT WITH A PERMANENT MARKER SETTINGS (SHARPIE®) JUMPER 1 2 3 4 5 6 ON MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT OPERATION JUMPER SETTINGS MUST BE SET AS SHOWN FOR ANALOG INPUT PROPER JUMPER OPERATION SETTINGS THERM ANALOG INPUT 4-20mA AI2 AI1 JUMPER 0-10V SETTINGS 0-5V 1 2 3 4 AI2 AI1 GND ON 1 2 3 4 5 6 Jumper Must Be Set To 0-5V As Shown 0-10V 0-10V 0-5V 0-5V AI2 AI3 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI3 AI4 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI4 THERM 4-20mA I2C 0-10V 0-5V EXPANSION NOTE: AO1 = BUILDING PRESSURE CONTROL VFD OR ALL BINARY INPUTS MUST BE(0-10 24 VAC DAMPER ACTUATOR ORONLY. 2-10 VDC) AO2 = MODULATING HEATING SIGNAL (0-10 VDC OR 2-10 VDC) AO1 PRESSURE CONTROL VFD OR AO3==BUILDING MODULATING COOLING/DIGITAL SCROLL DAMPER OR 2-10 SIGNAL ACTUATOR (0-10 VDC, (0-10 2-10 VDC ORVDC) 1.5-5 VDC) AO2 AO4==MODULATING RETURN AIRHEATING DAMPERSIGNAL ACTUATOR (0-10 OR 2-10 VDC) (0-10VDC VDC) AO3 AO5==MODULATING RETURN AIRCOOLING/DIGITAL BYPASS DAMPERSCROLL ACTUATOR SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 VDC) AO4 AIRFOR DAMPER ACTUATOR GND==RETURN GROUND ANALOG OUTPUTS VDC) FOR ANALOG OUTPUTS GROUND GND =(0-10 AO5 = RETURN AIR BYPASS DAMPER ACTUATOR (0-10 VDC) GND GROUND FOR OUTPUTS AI1 == OUTDOOR AIRANALOG RH SENSOR (0-5 VDC) GND GROUNDAIR FORRH ANALOG OUTPUTS AI2 == INDOOR SENSOR (0-5 VDC) A3 I = ECONOMIZER FEEDBACK AI4 = BUILDING STATIC PRESSURE (0-5 VDC) AI1 = OUTDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI2 = INDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI3 = CO2 (0-10 VDC) AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label GND = GROUND FOR I2CANALOG INPUTS #LB102034-01-A EXPANSION Rev.: 1L ON Jumpers Must Be Set as Shown For Correct O-5 VDC Operation 1 & 3 Are Off 2 & 4 Are On THERM THERM 4-20mA 4-20mA RELAY 3= BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT FLOW4 -=N.O. INPUT BI3 = PROOF OFRELAY BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT REMOTE HEATING - N.O. INPUT BI5==HOOD BI1 ON -FORCED N.O. INPUT REMOTE FORCED COOLING - N.O. INPUT BI6==DIRTY FILTER - N.O. INPUT BI2 N.O. INPUT BI3 HOOD OF ONFLOW - N.O.-INPUT BI7==PROOF OCCUPIED - N.O. INPUT BI4 REMOTEFORCED DEHUMIDIFICATION - N.O. INPUT BI8==REMOTE BI5 = REMOTE FORCED HEATING - N.O. INPUT = REMOTE FORCED COOLING - N.O. INPUT BI6 NOTE: SMOKE DETECTOR - N.C. BI7 ALL=BINARY INPUTS MUST BEINPUT 24 VAC ONLY. BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT Jumpers Must Be Set as Shown For Normal Operation Of Sensor 1, 2, 4, 5 & 6 Are Off 3 Is On VCM-X Expansion Module Modular Cable Connect To VCM-X E-BUS Controller Modular Cable Connect To Next Expansion Board (When Used) JOB NAME S. Olson DATE: 05/14/15 FILENAME OVCMX-RA-HumSensorWr-1B.CDR DATE: 01/11/13 PAGE B. Crews DESCRIPTION: VCM-X Expansion Module 1 of 1 Return Air Humidity Sensor Figure 31: OE265-14 - Indoor Return Air Humidity Sensor Wiring 50 VCM-X Component & Systems Wiring VCM-X Expansion Module Wiring Title 24 Economizer Actuator Feedback 24 VAC GND WARNING OBSERVE 10 VA Minimum Power Required For VCM-X Expansion Module POLARITY WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VACto-24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 24 24 VAC VAC POWER POWER ONLY I2C I2C WattMaster Label ONLY WARNING! POLARITY MUST BE EXPANSION EXPANSION #LB102034-01 WARNING! OBSERVED OR THE BOARD POLARITY WILL BE DAMAGED MUST BE OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED VCM-X Expansion Module AAON No.: www.orioncontrols.com Orion No.:OE333-23-EM R69190 Economizer Damper Actuator (Belimo Actuator Shown) COM - 1 + 2 CONTACT OE333-23-EM-A EXPANSIONRELAY MODULE PR OUT TO VCM-XVCM-X INPUT RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RATING IS 1 AMP RELAY 1 GND TERMINALS AI5 & GND MAX @ 24 VAC SUCTION PRESSURE +V RELAY 2 TRANSDUCER CONNECTION SIG RELAY 1 FOR HVAC UNITS WITHOUT GND DIGITAL COMPRESSOR RELAY RELAY 2 3 SUCTION PRESSURE +V TRANSDUCER CONNECTION SIG RELAY RELAY 3 4 FOR HVAC UNITS WITHOUT GND DIGITAL COMPRESSOR RELAY RELAY 4 COMMON See Economizer Actuator Wiring AO1 For VCM-X Controller Y1 3 Economizer Feedback 5 Title 24 Economizer Actuator Feedback Signal 0-10VDC (By Others) RELAY 3 = RELAY 2 = RELAY 4 = RELAY 1= IT IS SUGGESTED THAT YOU WRITE THE DESCRIPTION RELAY 2 = OF THE RELAY OUTPUTS YOU ARE USING IN THE BOXES IT IS SUGGESTED PROVIDED ABOVE THAT YOU WRITE THE WITH A PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS YOU ARE USING IN THE BOXES PROVIDED ABOVE WITH A PERMANENT ANALOG INPUT MARKER (SHARPIE®) JUMPER SETTINGS NOTE: For Economizer Actuator Wiring, See AO1 Wiring For The VCM-X Controller. Belimo Actuator Wiring Shown. Consult Factory For Other Manufacturer Wiring Instructions RELAY 1 = MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT OPERATION JUMPER SETTINGS MUST BE SET AS SHOWN FOR ANALOG INPUT PROPER JUMPER OPERATION SETTINGS THERM ANALOG INPUT 4-20mA AI1JUMPER 0-10V SETTINGS 0-5V AI3 GND Jumper Must Be Set To 0-10V As Shown AI1 AI2 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI2 AI3 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI3 AI4 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI4 THERM 4-20mA I2C0-10V 0-5V EXPANSION RELAY COMMON VCM RELAY 3 = BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT RELAY 4 = BI3 = PROOF OF FLOW - N.O. INPUT BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT BI1 ON - FORCED N.O. INPUT REMOTE HEATING - N.O. INPUT BI5= =HOOD FILTER - N.O. INPUT BI2 REMOTE FORCED COOLING - N.O. INPUT BI6= =DIRTY N.O. INPUT BI3 HOODOF ONFLOW - N.O.- INPUT BI7= =PROOF FORCED OCCUPIED - N.O. INPUT BI4 REMOTE DEHUMIDIFICATION - N.O. INPUT BI8= =REMOTE BI5 = REMOTE FORCED HEATING - N.O. INPUT = REMOTE FORCED COOLING - N.O. INPUT BI6 NOTE: = BINARY SMOKE DETECTOR - N.C. INPUT BI7 ALL INPUTS MUST BE 24 VAC ONLY. BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT NOTE: AO1 = BUILDING PRESSURE CONTROL VFD OR ALL BINARY INPUTS MUST BE (0-10 24 VAC DAMPER ACTUATOR ORONLY. 2-10 VDC) AO2 = MODULATING HEATING SIGNAL (0-10 VDC OR 2-10 VDC) AO1 = BUILDING PRESSURE CONTROL VFDSCROLL OR AO3 = MODULATING COOLING/DIGITAL DAMPER ACTUATOR (0-10 OR 2-10 SIGNAL (0-10 VDC, 2-10 VDC ORVDC) 1.5-5 VDC) AO2 AO4= =MODULATING RETURN AIRHEATING DAMPERSIGNAL ACTUATOR (0-10 VDC OR 2-10 VDC) (0-10 VDC) AO3 SCROLL AO5= =MODULATING RETURN AIRCOOLING/DIGITAL BYPASS DAMPER ACTUATOR SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 VDC) AO4 = RETURN AIRFOR DAMPER ACTUATOR GND = GROUND ANALOG OUTPUTS VDC) FOR ANALOG OUTPUTS GND (0-10 = GROUND AO5 = RETURN AIR BYPASS DAMPER ACTUATOR (0-10 VDC) GND FOR ANALOG OUTPUTS AI1 == GROUND OUTDOOR AIR RH SENSOR (0-5 VDC) GND FORRH ANALOG OUTPUTS AI2 == GROUND INDOOR AIR SENSOR (0-5 VDC) A3 I = ECONOMIZER FEEDBACK AI4 = BUILDING STATIC PRESSURE (0-5 VDC) AI1 = OUTDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS = INDOOR AIR RH SENSOR (0-5 VDC) AI2 GND = GROUND FOR ANALOG INPUTS = CO2 (0-10 VDC) AI3 AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label GND = GROUND FOR I2CANALOG INPUTS #LB102034-01-A EXPANSION Rev.: 1L Modular Cable Connect To VCM-X E-BUS Controller VCM-X Expansion Module Modular Cable Connect To Next Expansion Board (When Used) JOB NAME FILENAME OVCMX-Econo-Fdbk-1A.CDR DATE: 05/15/15 PAGE DRAWN BY: S.OLSON DESCRIPTION: VCM-X Expansion Module 1 of 1 Title 24 Economizer Actuator Feedback Wiring Figure 32: Title 24 Economizer Actuator Feedback Wiring VCM-X Component & Systems Wiring 51 VCM-X Expansion Module Wiring Building Pressure Sensor, Actuator & VFD WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to-24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 10 VA Minimum Power Required For VCM-X Expansion Module POLARITY EXC Note: Both Types Of Building Pressure Control Devices Are Shown Below. Only One Type Of Building Pressure Control Device (Not Both) May Be Used On Each HVAC Unit. 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION WARNING! EXPANSION #LB102034-01 OBSERVED OR THE BOARD POLARITY WILLBE BE DAMAGED MUST OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED Wiring When Using Damper Actuator For Building Pressure Control VCM-X Expansion Module AAON No.: Orion No.:OE333-23-EMwww.orioncontrols.com R69190 OUT RELAY 1 = RELAY 3 = RELAY 2 = Tubing To Outdoor Pressure Sensing Tubing To Location Building Pressure Sensing Location YOU ARE USING IN THE BOXES PROVIDED ABOVE ANALOG INPUT WITH A PERMANENT MARKERSETTINGS (SHARPIE®) JUMPER MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT OPERATION JUMPER SETTINGS MUST BE SET AS SHOWN FOR ANALOG INPUT PROPER JUMPER OPERATION SETTINGS THERM ANALOG 4-20mA INPUT AI1 JUMPER 0-10V SETTINGS 0-5V AI4 GND AI2 AI1 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI2 AI3 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI3 AI4 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI4 RELAY COMMON 2+ VCM 3 Y1 RELAY 4 = 1= IT RELAY IS SUGGESTED THAT YOU WRITE THE DESCRIPTION OF RELAY = THE RELAY2OUTPUTS YOU ARE USING IN THE BOXES IT IS SUGGESTED PROVIDED ABOVE THAT YOU WRITE THE WITH A PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS THERM 4-20mA 0-10V I2C 0-5V EXPANSION Building Pressure Control Damper Actuator (By Others - Belimo Actuator Shown) 1 - COM GND COM 24 VAC RELAY CONTACT PR OE333-23-EM-A OUT TO VCM-X INPUT VCM-X EXPANSION MODULE RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RELAY RATING IS 11AMP GND TERMINALS AI5 & GND SUCTION PRESSURE MAX @ 24 VAC +V RELAY 2 TRANSDUCER CONNECTION SIG FOR HVAC UNITS WITHOUT RELAY 1 GND DIGITAL COMPRESSOR RELAY 3 RELAY 2 SUCTION PRESSURE +V TRANSDUCER CONNECTION RELAY 4 SIG RELAY 3 FOR HVAC UNITS WITHOUT GND RELAY DIGITAL COMPRESSOR COMMON RELAY 4 - RELAY 3= BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT BI3 = PROOF OFRELAY FLOW4- =N.O. INPUT BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT BI5 REMOTE HEATING - N.O. INPUT BI1 = HOOD ON FORCED - N.O. INPUT BI6 REMOTE FORCED - N.O. INPUT FILTER - N.O. COOLING INPUT BI2 = DIRTY BI7 HOOD ON N.O. INPUT BI3 = PROOF OF -FLOW - N.O. INPUT BI8 REMOTEFORCED DEHUMIDIFICATION - N.O. INPUT BI4 = REMOTE OCCUPIED - N.O. INPUT BI5 = REMOTE FORCED HEATING - N.O. INPUT BI6 = REMOTE FORCED COOLING - N.O. INPUT NOTE: BI7 =BINARY SMOKEINPUTS DETECTOR - N.C. ALL MUST BEINPUT 24 VAC ONLY. BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT Building Pressure Control Exhaust Fan Variable Frequency Drive (By Others) AO1 = BUILDING PRESSURE CONTROL VFD OR NOTE: ALL BINARY INPUTS MUST BE 24 VAC DAMPER ACTUATOR (0-10 OR ONLY. 2-10 VDC) AO2 = MODULATING HEATING SIGNAL (0-10 VDC OR 2-10 VDC) AO1 = PRESSURE CONTROL VFD OR AO3 = BUILDING MODULATING COOLING/DIGITAL SCROLL DAMPER ACTUATOR (0-10VDC OR 2-10 VDC) VDC) SIGNAL (0-10 VDC, 2-10 OR 1.5-5 = MODULATING HEATING SIGNAL AO2 AO4 = RETURN AIR DAMPER ACTUATOR (0-10 (0-10VDC VDC)OR 2-10 VDC) COOLING/DIGITAL AO3 = AO5 = MODULATING RETURN AIR BYPASS DAMPERSCROLL ACTUATOR SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 VDC) AO4 ==RETURN AIR DAMPER ACTUATOR GND GROUND FOR ANALOG OUTPUTS VDC) FOR ANALOG OUTPUTS GND =(0-10 GROUND AO5 = RETURN AIR BYPASS DAMPER ACTUATOR (0-10 VDC) GND = GROUND FOR ANALOG OUTPUTS AI1 = OUTDOOR AIR RH SENSOR (0-5 VDC) GND==INDOOR GROUNDAIR FOR ANALOG OUTPUTS RH SENSOR (0-5 VDC) AI2 I = ECONOMIZER FEEDBACK A3 AI4 = BUILDING STATIC PRESSURE (0-5 VDC) AI1 = OUTDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI2 = INDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI3 = CO2 (0-10 VDC) AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label GND = GROUND FOR I2C ANALOG INPUTS #LB102034-01-A EXPANSION Rev.: 1L AO1 LOW + + + - HIGH + OE258-01 Building Pressure Sensor WARNING OBSERVE 24 VAC GND + Sheild Sheild GND GND _ GND Wiring When Using Exhaust Fan VFD For Building Pressure Control Caution: The VFD Unit Must Be Configured For 0-10VDC Input. The Input Resistance At The VFD Must Not Be Less Than 1000 Ohms When Measured At The VFD Terminals With All Input Wires Removed. Jumper Must Be Set To 0-5V As Shown VCM-X Expansion Module Note: Wire To The VFD Using 18 GA Minimum 2 Conductor Twisted Pair With Shield Cable. Wire Shield To GND As Shown. JOB NAME BY: S. Olson DATE: 05/14/15 FILENAME OVCMX-BldgPr-Wr-1A.CDR DATE: 01/11/13 PAGE DRAWN BY: B. Crews DESCRIPTION: VCM-X Expansion Module 1 of 1 Building Pressure Sensor, Actuator & VFD Wiring Figure 33: OE258-01 - Building Pressure Sensor & Actuator & VFD Wiring 52 VCM-X Component & Systems Wiring VCM-X Expansion Module Wiring Modulating Heating Device WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to-24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. POLARITY WARNING OBSERVE 24 VAC GND 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION WARNING! EXPANSION #LB102034-01 OBSERVED OR THE BOARD POLARITY WILLBE BE DAMAGED MUST OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED Note: 1.) The Modulating Heating Device Used On The VCM-X Controller Must Have (1) Relay Output Configured For It In Order To Enable The Modulating Heating Device's Sequence. This Relay Output Must Be Configured When Setting Up The VCM-X Controller Operating Parameters. The Modulating Heating Output’s Voltage Can Also Be Configured For Either 0 To 10 VDC Or 2 To 10 VDC In The Configuration Menu. VCM-X Expansion Module AAON No.: Orion No.:OE333-23-EMwww.orioncontrols.com R69190 RELAY CONTACT PR OE333-23-EM-A OUT TO VCM-X INPUT VCM-X EXPANSION MODULE RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RELAY RATING IS 11AMP GND TERMINALS AI5 & GND SUCTION PRESSURE MAX @ 24 VAC +V RELAY 2 TRANSDUCER CONNECTION SIG FOR HVAC UNITS WITHOUT RELAY 1 GND DIGITAL COMPRESSOR RELAY 3 RELAY 2 SUCTION PRESSURE +V TRANSDUCER CONNECTION RELAY 4 SIG RELAY 3 FOR HVAC UNITS WITHOUT GND RELAY DIGITAL COMPRESSOR COMMON RELAY 4 RELAY 1 = RELAY 3 = RELAY 2 = RELAY 4 = 1= IT RELAY IS SUGGESTED THAT YOU WRITE THE DESCRIPTION OF RELAY = THE RELAY2OUTPUTS YOU ARE USING IN THE BOXES IT IS SUGGESTED PROVIDED ABOVE THAT YOU WRITE THE WITH A PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS YOU ARE USING IN THE BOXES PROVIDED ABOVE ANALOG INPUT WITH A PERMANENT MARKERSETTINGS (SHARPIE®) JUMPER MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT OPERATION JUMPER SETTINGS MUST BE SET AS SHOWN FOR ANALOG INPUT PROPER JUMPER OPERATION SETTINGS THERM ANALOG 4-20mA INPUT AI1 JUMPER 0-10V SETTINGS 0-5V AI2 AI1 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI2 AI3 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI3 AI4 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI4 THERM 4-20mA I2C 0-10V 0-5V EXPANSION VCM-X Expansion Module RELAY COMMON VCM RELAY 3= BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT FLOW4- =N.O. INPUT BI3 = PROOF OFRELAY BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT REMOTE HEATING - N.O. INPUT BI5 BI1 = HOOD ON FORCED - N.O. INPUT REMOTE FORCED - N.O. INPUT BI6 FILTER - N.O. COOLING INPUT BI2 = DIRTY HOOD ON N.O. INPUT BI7 OF -FLOW - N.O. INPUT BI3 = PROOF REMOTEFORCED DEHUMIDIFICATION - N.O. INPUT BI8 OCCUPIED - N.O. INPUT BI4 = REMOTE BI5 = REMOTE FORCED HEATING - N.O. INPUT BI6 = REMOTE FORCED COOLING - N.O. INPUT NOTE: BI7 =BINARY SMOKEINPUTS DETECTOR - N.C. ALL MUST BEINPUT 24 VAC ONLY. BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT AO1 = BUILDING PRESSURE CONTROL VFD OR NOTE: ALL BINARY INPUTS MUST BE 24 VAC DAMPER ACTUATOR (0-10 OR ONLY. 2-10 VDC) AO2 = MODULATING HEATING SIGNAL (0-10 VDC OR 2-10 VDC) AO1 = PRESSURE CONTROL VFD OR AO3 = BUILDING MODULATING COOLING/DIGITAL SCROLL DAMPER ACTUATOR (0-10VDC OR 2-10 VDC) VDC) SIGNAL (0-10 VDC, 2-10 OR 1.5-5 HEATING SIGNAL AO2 = AO4 = MODULATING RETURN AIR DAMPER ACTUATOR (0-10 (0-10VDC VDC)OR 2-10 VDC) = MODULATING COOLING/DIGITAL SCROLL AO3 AO5 = RETURN AIR BYPASS DAMPER ACTUATOR SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 VDC) AO4 ==RETURN AIR DAMPER ACTUATOR GND GROUND FOR ANALOG OUTPUTS VDC) FOR ANALOG OUTPUTS GROUND GND =(0-10 AO5 = RETURN AIR BYPASS DAMPER ACTUATOR (0-10 VDC) GND==OUTDOOR GROUND FOR OUTPUTS AI1 AIR ANALOG RH SENSOR (0-5 VDC) GND==INDOOR GROUNDAIR FOR ANALOG OUTPUTS AI2 RH SENSOR (0-5 VDC) A3 I = ECONOMIZER FEEDBACK AI4 = BUILDING STATIC PRESSURE (0-5 VDC) AI1 = OUTDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI2 = INDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI3 = CO2 (0-10 VDC) 10 VA Minimum Power Required For VCM-X Expansion Module Modulating Heating Device (0 To 10 VDC Or 2 To 10 VDC Input) AO2 + GND _ GND AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label GND = GROUND FOR I2C ANALOG INPUTS #LB102034-01-A EXPANSION Rev.: 1L Modular Cable Connect To Next Expansion Board (When Used) Modular Cable Connect To VCM-X Controller JOB NAME FILENAME OVCMX-Mod-Heat-Output-1B.CDR DATE: 05/15/15 PAGE S. Olson DESCRIPTION: VCM-X Expansion Module 1 of 1 Modulating Heating Output Figure 34: Modulating Heating Device Wiring VCM-X Component & Systems Wiring 53 VCM-X Expansion Module Wiring Modulating Cooling Device WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to-24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 24 VAC GND POLARITY WARNING OBSERVE 10 VA Minimum Power Required For VCM-X Expansion Module 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION WARNING! EXPANSION #LB102034-01 OBSERVED OR THE BOARD POLARITY WILLBE BE DAMAGED MUST OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED VCM-X Expansion Module AAON No.: Orion No.:OE333-23-EMwww.orioncontrols.com R69190 2.) The Modulating Cooling Device Used On The VCM-X Controller Must Have (1) Relay Output Configured In Order To Enable The Modulating Cooling Device's Sequence. This Relay Output Must Be Configured When Setting Up The VCM-X Controller Operating Parameters. RELAY CONTACT PR OE333-23-EM-A OUT TO VCM-X INPUT VCM-X EXPANSION MODULE RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RELAY RATING IS 11AMP GND TERMINALS AI5 & GND SUCTION PRESSURE MAX @ 24 VAC +V RELAY 2 TRANSDUCER CONNECTION SIG FOR HVAC UNITS WITHOUT RELAY 1 GND DIGITAL COMPRESSOR RELAY 3 RELAY 2 SUCTION PRESSURE +V TRANSDUCER CONNECTION RELAY 4 SIG RELAY 3 FOR HVAC UNITS WITHOUT GND RELAY DIGITAL COMPRESSOR COMMON RELAY 4 RELAY 1 = RELAY 3 = RELAY 2 = RELAY 4 = IT RELAY IS SUGGESTED 1= THAT YOU WRITE THE DESCRIPTION OF RELAY = THE RELAY2OUTPUTS YOU ARE USING IN THE BOXES IT IS SUGGESTED PROVIDED ABOVE THAT WRITE THE WITH A YOU PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS YOU ARE USING IN THE BOXES PROVIDED ABOVE ANALOG INPUT WITH A PERMANENT JUMPER MARKERSETTINGS (SHARPIE®) MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT OPERATION JUMPER SETTINGS MUST BE SET AS SHOWN FOR ANALOG INPUT PROPER JUMPER OPERATION SETTINGS THERM ANALOG 4-20mA INPUT AI1 0-10V JUMPER 0-5V SETTINGS AI2 AI1 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI3 AI2 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI4 AI3 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI4 THERM 4-20mA I2C 0-10V 0-5V EXPANSION VCM-X Expansion Module RELAY COMMON VCM RELAY 3= BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT BI3 = PROOF OFRELAY FLOW4- =N.O. INPUT BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT BI5 REMOTE HEATING - N.O. INPUT BI1 = = HOOD ON FORCED - N.O. INPUT BI6 REMOTE FORCED - N.O. INPUT BI2 = = DIRTY FILTER - N.O. COOLING INPUT BI7 HOOD ON N.O. INPUT BI3 = PROOF OF -FLOW - N.O. INPUT BI8 REMOTEFORCED DEHUMIDIFICATION - N.O. INPUT BI4 = REMOTE OCCUPIED - N.O. INPUT BI5 = REMOTE FORCED HEATING - N.O. INPUT NOTE: BI6 = REMOTE FORCED COOLING - N.O. INPUT ALL MUST BE INPUT 24 VAC ONLY. BI7 =BINARY SMOKEINPUTS DETECTOR - N.C. BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT AO1 = BUILDING PRESSURE CONTROL VFD OR NOTE: DAMPER ACTUATOR (0-10 OR ONLY. 2-10 VDC) ALL BINARY INPUTS MUST BE 24 VAC AO2 = MODULATING HEATING SIGNAL (0-10 VDC OR 2-10 VDC) AO1 = BUILDING PRESSURE CONTROL VFD OR MODULATING COOLING/DIGITAL SCROLL AO3 DAMPER ACTUATOR (0-10VDC OR 2-10 VDC) VDC) SIGNAL (0-10 VDC, 2-10 OR 1.5-5 HEATING SIGNAL AO2 = MODULATING RETURN AIR DAMPER ACTUATOR AO4 (0-10 (0-10 VDC VDC)OR 2-10 VDC) COOLING/DIGITAL AO3 = MODULATING RETURN AIR BYPASS DAMPERSCROLL ACTUATOR AO5 SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 VDC) AO4 ==RETURN AIR DAMPER ACTUATOR GND GROUND FOR ANALOG OUTPUTS VDC) FOR ANALOG OUTPUTS GND =(0-10 GROUND AO5 = RETURN AIR BYPASS DAMPER ACTUATOR (0-10 VDC) AI1 AIR ANALOG RH SENSOR (0-5 VDC) GND==OUTDOOR GROUND FOR OUTPUTS AI2 RH SENSOR (0-5 VDC) GND==INDOOR GROUNDAIR FOR ANALOG OUTPUTS A3 I = ECONOMIZER FEEDBACK AI4 = BUILDING STATIC PRESSURE (0-5 VDC) AI1 = =OUTDOOR RHANALOG SENSORINPUTS (0-5 VDC) GND GROUNDAIR FOR AI2 = =INDOOR AIRFOR RH SENSOR VDC) GND GROUND ANALOG(0-5 INPUTS AI3 = CO2 (0-10 VDC) AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label I2C ANALOG INPUTS GND = GROUND FOR #LB102034-01-A EXPANSION Rev.: 1L Note: 1.) The Modulating Cooling Device Used Must Be Capable Of Accepting Either A 0-10 VDC, 2-10 VDC, Or 1.5-5.0 VDC Input. The Modulating Cooling Output Voltage Is User- Configurable For These Voltages. This Voltage Output Must Be Configured When You Are Setting Up The VCM-X Controller’(s) Operating Parameters. AO3 + GND _ GND Modulating Cooling Device 0-10 VDC, 2-10 VDC or 1.5-5.0 VDC (Configurable) Modular Cable Connect To Next Expansion Board (When Used) Modular Cable Connect To VCM-X E-BUS Controller JOB NAME FILENAME OVCMX-Mod-Cool-Output-1B.CDR DATE: 05/15/15 PAGE S. Olson DESCRIPTION: VCM-X Expansion Module 1 of 1 Modulating Cooling Output Figure 35: Modulating Cooling Device Wiring 54 VCM-X Component & Systems Wiring VCM-X Expansion Module Wiring Return Air Bypass WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to-24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. 24 VAC POLARITY WARNING OBSERVE GND 10 VA Minimum Power Required For VCM-X Expansion Module 24 VAC POWER 24 VAC POWER ONLY I2C I2C ONLY WattMaster Label WARNING! POLARITY MUST BE EXPANSION WARNING! EXPANSION #LB102034-01 OBSERVED OR THE BOARD POLARITY WILL BE MUST BE DAMAGED OBSERVED OR THE BOARD www.aaon.com WILL BE www.orioncontrols.com DAMAGED VCM-X Expansion Module AAON No.: Orion No.:OE333-23-EM R69190 www.orioncontrols.com Belimo Actuator Wiring Shown. Consult Factory For Other Manufacturer Wiring Instructions. CONTACT PROE333-23-EM-A OUT TO VCM-XVCM-X INPUT EXPANSIONRELAY MODULE RATING IS 1 AMP GND TERMINALS AI5 & GND MAX @ 24 VAC RELAY CONTACT PR OUT TO VCM-X INPUT RELAY 1 RATING IS 1 AMP GND TERMINALS AI5 & GND SUCTION PRESSURE MAX @ 24 VAC +V RELAY 2 TRANSDUCER CONNECTION SIG FOR HVAC UNITS WITHOUT RELAY 1 GND DIGITAL COMPRESSOR RELAY 3 RELAY 2 SUCTION PRESSURE +V TRANSDUCER CONNECTION RELAY 4 SIG RELAY 3 FOR HVAC UNITS WITHOUT GND RELAY DIGITAL COMPRESSOR COMMON RELAY 4 RELAY 1 = RELAY 3 = RELAY 2 = ITRELAY IS SUGGESTED 1= THAT YOU WRITE THE DESCRIPTION OF RELAY 2 OUTPUTS = THE RELAY YOU ARE USING IN THE BOXES IT IS SUGGESTED PROVIDED ABOVE THATAYOU WRITE THE WITH PERMANENT DESCRIPTION OF MARKER (SHARPIE®) THE RELAY OUTPUTS YOU ARE USING IN THE BOXES PROVIDED ABOVE ANALOG INPUT WITH A PERMANENT JUMPER MARKER SETTINGS (SHARPIE®) MUST BE SET AS SHOWN FOR PROPER ANALOG INPUT OPERATION JUMPER SETTINGS MUST BE SET AS SHOWNINPUT FOR ANALOG PROPER JUMPER OPERATION SETTINGS THERM 4-20mA ANALOG INPUT AI1 0-10V JUMPER 0-5V SETTINGS AI2 AI1 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI3 AI2 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V AI4 AI3 THERM THERM 4-20mA 4-20mA 0-10V 0-10V 0-5V 0-5V THERM 4-20mA AI4 I2C 0-10V 0-5V EXPANSION RELAY COMMON Return Air Damper Actuator (0-10 VDC) VCM RELAY 4 = RELAY 3= BI1 = EMERGENCY SHUTDOWN - N.C. INPUT BI2 = DIRTY FILTER - N.O. INPUT RELAY 4= FLOW - N.O. INPUT BI3 = PROOF OF BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT = REMOTE FORCED HEATING - N.O. INPUT BI5 BI1 = HOOD ON - N.O. INPUT REMOTE FORCED COOLING - N.O. INPUT BI6==DIRTY BI2 FILTER - N.O. INPUT HOOD OF ONFLOW - N.O.- INPUT BI7==PROOF BI3 N.O. INPUT = REMOTE DEHUMIDIFICATION - N.O. INPUT BI8 BI4 = REMOTE FORCED OCCUPIED - N.O. INPUT BI5 = REMOTE FORCED HEATING - N.O. INPUT NOTE: BI6 = REMOTE FORCED COOLING - N.O. INPUT ALL BINARY INPUTS MUST BE 24 VAC ONLY. BI7 = SMOKE DETECTOR - N.C. INPUT BI8 = REMOTE DEHUMIDIFICATION - N.O. INPUT AO1 = BUILDING PRESSURE CONTROL VFD OR NOTE: DAMPER ACTUATOR OR 2-10 VDC) ALL BINARY INPUTS MUST BE (0-10 24 VAC ONLY. AO2 = MODULATING HEATING SIGNAL (0-10 VDC OR 2-10 VDC) AO3==BUILDING MODULATING COOLING/DIGITAL AO1 PRESSURE CONTROL VFDSCROLL OR SIGNALACTUATOR (0-10 VDC, (0-10 2-10 OR VDC ORVDC) 1.5-5 VDC) DAMPER 2-10 AO2 AO4==MODULATING RETURN AIRHEATING DAMPERSIGNAL ACTUATOR (0-10 OR 2-10 VDC) (0-10VDC VDC) SCROLL AO3 AO5==MODULATING RETURN AIRCOOLING/DIGITAL BYPASS DAMPER ACTUATOR SIGNAL (0-10 VDC, 2-10 VDC OR 1.5-5 VDC) (0-10 VDC) RETURN AIRFOR DAMPER ACTUATOR AO4 GND= = GROUND ANALOG OUTPUTS (0-10 VDC) FOR ANALOG OUTPUTS GROUND GND = AO5 = RETURN AIR BYPASS DAMPER ACTUATOR (0-10 VDC) AI1 = OUTDOOR AIRANALOG RH SENSOR (0-5 VDC) GND = GROUND FOR OUTPUTS AI2 = INDOOR AIR SENSOR (0-5 VDC) GND = GROUND FORRH ANALOG OUTPUTS A3 I = ECONOMIZER FEEDBACK AI4 = BUILDING STATIC PRESSURE (0-5 VDC) AI1 = OUTDOOR AIR RH ANALOG SENSOR (0-5 VDC) GND = GROUND FOR INPUTS AI2 = INDOOR AIR RH SENSOR (0-5 VDC) GND = GROUND FOR ANALOG INPUTS AI3 = CO2 (0-10 VDC) AI4 = BUILDING STATIC PRESSURE (0-5 VDC) GND = GROUND FOR ANALOG INPUTS WattMaster Label I2CANALOG INPUTS GND = GROUND FOR #LB102034-01-A EXPANSION Rev.: 1L VCM-X Expansion Module 1 COM 2 + 3 Y1 AO4 AO5 GND 1 COM 2 + 3 Y1 Return Air Bypass Damper Actuator (0-10 VDC) Modular Cable Connect To Next Expansion Board (When Used) Modular Cable Connect To VCM-X E-BUS Controller JOB NAME FILENAME OVCMX-RA-BYP-Wr-1B.cdr DATE: 05/15/15 PAGE BY: S. Olson DESCRIPTION: VCM-X Expansion Module 1 of 1 Return Air Bypass Wiring Figure 36: Return Air Bypass Wiring VCM-X Component & Systems Wiring 55 VCM-X Expansion Module Wiring 12 Relay Expansion Module WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24VAC-to-24VAC. Failure to observe polarity will result in damage to one or more of the boards. Expansion Modules must be wired in such a way that the expansion modules and the controller are always powered together. Loss of power to the expansion module will cause the controller to become inoperative until power is restored to the expansion module. Modular Cable Connect To VCM-X E-BUS Controller Modular Cable Connect To Next Expansion Board (When Used) 24 VAC 15 VA Minimum Power GND Required For 12 Relay Expansion Module Set Jumper As Shown Below When Only The 12 Relay Expansion Module Is Used EXP1 EXP2 Note: All Relay Outputs Are Normally Open And Rated For 24 VAC Power Only. 1 Amp Maximum Load. OE358-23-12R 12-Relay Expansion Module POWER 24VAC GND 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE BOARD WILL BE DAMAGED I2C EXPANSION WattMaster Label #LB102043 RELAY I2C EXPANSION EXPANSION BOARD YS102228 REV 1 EXP1 R1 R2 R3 R4 Configurable Relay Output #1 Configurable Relay Output #2 Configurable Relay Output #3 Configurable Relay Output #4 RLY6 OE358-23-12R-A 12 RELAY EXPANSION MODULE EXP1 EXP2 RLY1 RLY2 RLY 1 = RLY 7 = RLY 2 = RLY 8 = RLY 3 = RLY 9 = RLY 4 = RLY 10 = RLY 5 = RLY 11 = RLY 6 = RLY 12 = RLY7 RLY8 RLY COM NOTE: IT IS RECOMMENDED THAT YOU WRITE THE DESCRIPTION OF THE RELAY OUTPUTS YOU ARE CONNECTING TO THE RELAY EXPANSION MODULE IN THE BOXES PROVIDED ABOVE USING A PERMANENT MARKER (SHARPIE)® FOR FUTURE REFERENCE. RLY COM R9 Configurable Relay Output #9 R10 Configurable Relay Output #10 R11 Configurable Relay Output #11 R12 Configurable Relay Output #12 RLY9 RLY10 RLY3 RLY4 R5 Configurable Relay Output #5 R6 Configurable Relay Output #6 R7 Configurable Relay Output #7 R8 Configurable Relay Output #8 RLY5 www.orioncontrols.com EXP2 Set Jumper As Shown Above When Both The 12 Relay & VCM-X Expansion Module Are Used Relay Output Contacts R1 Thru R12 May Be User-Configured For The Following: 1 - Heating Stages 2 - Cooling Stages 3 - Warm-up Mode Command (VAV Boxes) 4 - Reversing Valve (Heat Pumps) 5 - Reheat Control (Dehumidification) 6 - Exhaust Fan Interlock 7 - Preheater For Low Ambient Protection 8 - Alarm 9 - Override 10 - Occupied 11 - OA Damper 12 - Heat Wheel 13 - Emergency Heat Note: A Total Of 20 Relays Are Available By Adding Relay Expansion Modules. All Expansion Module Relay Outputs Are User- Configurable As Listed Above. RLY11 J1 J1 EXP1 EXP2 SET JUMPER AS SHOWN WHEN ONLY THE 12 RELAY EXPANSION MODULE IS USED EXP1 EXP2 SET JUMPER AS SHOWN WHEN BOTH THE VCM EXPANSION MODULE AND THE RELAY EXPANSION MODULE ARE USED RLY12 RLY COM MADE IN USA JOB NAME FILENAME OVCMX-12RelayWire-1A.CDR DATE: 01/11/13 PAGE 1 of 1 S. Olson DESCRIPTION: VCM-X Controller Wiring Detail 12 Relay Expansion Module Figure 37: OE358-23-12R - 12 Relay Expansion Module Wiring 56 VCM-X Component & Systems Wiring VCM-X Expansion Module Wiring Airflow Monitoring Station Connect To VCM-X E-BUS Port VCM-X E-BUS Controller ANALOG INPU JUMPER SETTINGS AI1 SET AI1 AI3 AI5 AI4 SET AI7 AI3 SET AI4 AI2 SET AI2 AI1 THERM 4-20mA 0-10V 0-5V THERM AI2 4-20mA 0-10V 0-5V AI3 THERM 4-20mA 0-10V 0-5V AI5 SET AI4 THERM 4-20mA 0-10V 0-5V AI5 THERM 4-20mA 0-10V 0-5V AI7 THERM 4-20mA 0-10V 0-5V EMERGENCY SHUTDOWN AI7 SET ANALOG INPUT JUMPER SETTINGS MUST BE SET AS SHOWN FOR PROPER OPERATION STATIC PRESSURE WattMaster Label #LB102033-01 Airflow Measurement Digital Transmitter Terminals For Supply Air CFM (Set Address Switch To 11) NET+ NETCOMM 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED Airflow Measurement Digital Transmitter Terminals For Return Air CFM (Set Address Switch To 10) I2C DIGITAL SENSOR I2C EXPANSION NET+ NETCOMM Airflow Measurement Digital Transmitter Terminals For Outdoor Air CFM (Set Address Switch To 9) NET+ NETCOMM OE365-15-EBA E-BUS Adapter Board HSSC Cable Connect To VCM-X E-BUS Port JOB NAME FILENAME OVCMX-Airflow-Station-1A.cdr DATE: 05/15/15 PAGE BY: S. Olson DESCRIPTION: VCM-X Expansion Module 1 of 1 Airflow Monitoring Station Wiring Figure 38: OE365-15-EBA - EBTRON® GTC116 Series, GreenTrolTM GA-200-N Series, and Paragon MicroTransEQ Series Air Flow Measurement Digital Transmitter Wiring VCM-X Component & Systems Wiring 57 VCM-X Expansion Module Wiring 58 Zone Zone VCM-X Component & Systems Wiring Modular & Non-Modular VAV/Zone Controller Wiring Modular & Non-Modular VAV/Zone Controller Diagrams VCM-X Component & Systems Wiring 59 Zone Modular & Non-Modular VAV/Zone Controller Wiring Zone Modular VAV/Zone Controller Actuator Package Wiring OE325-01 Fan & Reheat Expansion Module (See Reheat Board Wiring For Detailed Wiring Connections) 5A30VDC CHINA 10A250VAC ~ 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VDE 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE SA 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE OMRON G5Q-1A4 DC24V YS102252 REV 1 R4 R3 R2 R1 STAT OE217-00 / OE217-01 Digital Room Sensor PIC18F4520 OE210-02, OE211-02, OE212-02 Or OE213-02 Modular Room Sensor Wiring When Using A Digital Room Sensor WATMASTER CONTROLS INC. MADE IN USA PWR Wiring When Using A Modular Sensor Rc AOUT GND Note: The Total Length Of Cable Cannot Exceed 160 Feet. ZONE EXPANSION RELAYS ANALOG OUTPUT Note: The Total Length Of Cable Cannot Exceed 160 Feet. COMM This Expansion Module Is Only Required For Single Duct Terminal Units With Reheat And All Fan Terminal Units EXPANSION IN AIN OVERRIDE ALARM Display Override GND FMRSC Cable ANALOG INPUT VREF THERM 4-20mA 0-10V 0-5V TSDRSC Cable Connect FRP Tubing (By Others) To Terminal Unit Air Flow Pickup Tube Hi & Lo Ports (P.I. VAV/Zone Controller Packages Only) TSDRSC Or FMRSC Cable As Required. Select Cable Depending On Sensor(s) Used. See Notes Above For Details Optional - Supply Air Temperature Sensor. Only Required When The Orion VCM-X Controller Is Not Installed On The HVAC Unit Connected To The Terminal Units.Locate In Ductwork Downstream Of The Terminal Unit Modular Expansion Cable Supplied With OE325-01 Expansion Module Connector Not Used With This Product www.orioncontrols.com 0 OE744-31-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE Power/Comm Cable To Next VAV/Zone Controller Actuator Package, System Manager Or Power/Comm Distribution Board OE282 REC POWER / CO OMM Power/Comm Cable From Previous VAV/Zone Controller Actuator Package, System Manager Or Power/Comm Distribution Board 1 Damper Actuator Damper Actuator Cable JOB NAME FILENAME ZCAP-MOD-Main-Wire-1A.CDR DATE: 01/16/13 PAGE S. Olson DESCRIPTION: OE742-31 & OE744-31 VAV/Zone Controller 1 of 1 Actuator Package Wiring Details Figure 39: OE742-31 & OE744-31 - Modular Zone Controller Actuator Package - P.I. & P.D. Wiring 60 VCM-X Component & Systems Wiring Modular & Non-Modular VAV/Zone Controller Wiring Non-Modular VAV/Zone Controller Actuator Package Wiring OE325-01 Fan & Reheat Expansion Module (See Reheat Board Wiring For Detailed Wiring Connections) 5A30VDC CHINA 10A250VAC ~ 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VDE 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE SA 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE OMRON G5Q-1A4 DC24V YS102252 REV 1 R4 R3 R2 STAT OE217-00 / OE217-01 Digital Room Sensor PIC18F4520 OE210-02, OE211-02, OE212-02 Or OE213-02 Modular Room Sensor Wiring When Using A Digital Room Sensor WATMASTER CONTROLS INC. MADE IN USA PWR Wiring When Using A Modular Sensor R1 Rc AOUT GND Note: The Total Length Of Cable Cannot Exceed 160 Feet. ZONE EXPANSION RELAYS ANALOG OUTPUT Note: The Total Length Of Cable Cannot Exceed 160 Feet. COMM This Expansion Module Is Only Required For Single Duct Terminal Units With Reheat And All Fan Terminal Units EXPANSION IN AIN OVERRIDE ALARM Display Override GND FMRSC Cable ANALOG INPUT VREF THERM 4-20mA 0-10V 0-5V TSDRSC Cable Connect FRP Tubing (By Others) To Terminal Unit Air Flow Pickup Tube Hi & Lo Ports (P.I. VAV/Zone Controller Packages Only) TSDRSC Or FMRSC Cable As Required. Select Cable Depending On Sensor(s) Used. See Notes Above For Details Optional - Supply Air Temperature Sensor. Only Required When The Orion VCM-X Controller Is Not Installed On The HVAC Unit Connected To The Terminal Units. Locate In Ductwork Downstream Of The Terminal Unit Modular Expansion Cable Supplied With OE325-01 Expansion Module Connector Not Used With This Product www.orioncontrols.com 0 OE744-32-VAVZ P.I. VAV/ZONE CONTROLLER ACTUATOR PACKAGE Wire To Previous And/Or Next VAV/Zone Controller Actuator Package Or Device On The Local Communications Loop Using 2 Conductor Twisted Pair With Shield Cable Available From WattMaster. All Communication Cable Used Must Be Belden 82760 Or Its Equivalent. OE282 T TB2 REC SHLD R T SHLD 24 VAC GND R 24VAC 24VAC GND WattMaster Label #LB102042-06 Rev. 01A GND TB3 Line Voltage WARNING: When Multiple VAV/Zone Controller Actuator Packages Are Powered From A Single Transformer Polarity Must Be Observed Or Damage To The Controllers Will Result. 1 STAT Damper Actuator Damper Actuator Cable 24 VAC Transformer. Size As Required For Number Of Controllers Connected. Each VAV/Zone Controller Actuator Package Requires 6 VA Minimum. JOB NAME FILENAME ZCAP-NM-Main-Wire-1A.CDR DATE: 01/16/13 PAGE S. Olson DESCRIPTION: OE742-32 & OE744-32 VAV/Zone Controller 1 of 7 Actuator Package Wiring Details Figure 40: OE742-32 & OE744-32 - Non-Modular Zone Controller Actuator Package - P.I. & P.D. Wiring VCM-X Component & Systems Wiring 61 Zone Modular & Non-Modular VAV/Zone Controller Wiring Zone Expansion Module Wiring PWR GND AOUT MADE IN USA WATMASTER CONTROLS INC. SA RELAYS VDE 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE RC Rc R1 VREF 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R3 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE C2 R4 5A30VDC CHINA 10A250VAC ~ 1st Stage Heat Contactor C1 R2 R3 R2 C3 2nd Stage Heat Contactor 3rd Stage Heat Contactor 24 VAC Contactor(s) Supplied & Wired By Others. YS102252 REV 1 ZONE EXPANSION PIC18F4520 AIN STAT GND COMM ANALOG INPUT 1 Amp Max. Load Each Note: 3 Stage Heating is Attained by Sizing All 3 Heating Elements For Equal KW Output. Each Element Should be Sized for 1/3 of the Total KW Output Required. To Achieve 3 Stage Heating the System would be Configured to Energize Contactor C1 for First Stage Heat. For 2nd Stage Heat the System Would be Configured to De-energize Typical Wiring for Contactor C1 and Energize Contactor C2 & C3. For 3rd Stage Heat the System Would be Configured to Single Duct Terminal Leave Contactor C2 & C3 Energized and also Energize Contactor C1. WattMaster Part #OE325-01 Expansion Module w/ Modular Cable Supplied by WattMaster Mounted by Others ANALOG OUTPUT EXPANSION IN PWR WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box ANALOG OUTPUT EXPANSION IN OMRON G5Q-1A4 DC24V THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster 24 VAC Transformer Supplied & Wired by Others. Size For Required Contactor(s) Load. 24VAC COM GND 24VAC 24 VAC Transformer Supplied & Wired by Others. Size For Required Fan Relay Load. AOUT COM MADE IN USA WATMASTER CONTROLS INC. Fan Relay Rc R1 R2 R3 24 VAC Fan Relay Supplied & Wired By Others. 1 Amp Max. Load R4 5A30VDC CHINA 10A250VAC ~ YS102252 REV 1 ZONE EXPANSION PIC18F4520 AIN STAT GND COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE ANALOG INPUT Typical Wiring for Fan Terminal Unit ANALOG OUTPUT PWR GND 24VAC AOUT EXPANSION IN COM 24 VAC Transformer Supplied & Wired by Others. Size For Required Contactor(s) Load. MADE IN USA WATMASTER CONTROLS INC. SA VDE C2 R3 C3 Fan Relay 1st Stage Heat Contactor C1 R4 2nd Stage Heat Contactor 3rd Stage Heat Contactor 24 VAC Fan Relay & Contactor(s) Supplied & Wired By Others. 1 Amp Max. Load Each YS102252 REV 1 ZONE EXPANSION PIC18F4520 AIN GND ANALOG INPUT WattMaster Part #OE325-01 Expansion Module w/ Modular Cable Supplied by WattMaster Mounted by Others Rc 5A30VDC CHINA 10A250VAC ~ R1 STAT COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE RC R1 R2 R3 R2 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R1 RELAYS OMRON G5Q-1A4 DC24V 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VREF WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box RC R1 R1 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE WattMaster Part #OE325-01 Expansion Module w/ Modular Cable Supplied by WattMaster Mounted by Others THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster VDE 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VREF WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box SA RELAYS OMRON G5Q-1A4 DC24V THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster Note: 3 Stage Heating is Attained by Sizing All 3 Heating Elements For Equal KW Output. Each Element Should be Sized for 1/3 of the Total KW Output Required. To Achieve 3 Stage Heating the System would be Configured to Energize Contactor C1 for First Stage Heat. For 2nd Stage Heat the System Would be Configured to De-energize Contactor C1 and Energize Contactor C2 & C3. For 3rd Stage Heat the System Would be Configured to Leave Contactor C2 & C3 Energized and also Energize Contactor C1. Typical Wiring for Fan Terminal With Electric Heat JOB NAME FILENAME ZCAP-Exp-Mod-Wire-1A.CDR DATE: 01/16/12 PAGE DRAWN BY: B. Crews DESCRIPTION: VAV/Zone Controller Actuator Packages 1 of 6 OE325-01 Expansion Module Wiring Details Figure 41: OE325-01 Expansion Module Wiring 62 VCM-X Component & Systems Wiring Modular & Non-Modular VAV/Zone Controller Wiring Expansion Module Wiring COM 24VAC GND + 24 VAC Transformer Supplied & Wired by Others. Size For Required HW Valve Load. PWR GND 0-10 VDC HWV AOUT MADE IN USA WATMASTER CONTROLS INC. SA RELAYS VDE R3 R4 YS102252 REV 1 ZONE EXPANSION 5A30VDC CHINA 10A250VAC ~ Rc PIC18F4520 AIN STAT GND COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE 0-10 VDC Modulating Hot Water Valve Supplied & Wired By Others R1 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R2 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VREF ANALOG INPUT Remove Control Board from Snaptrack & Mount Snaptrack on Box ANALOG OUTPUT EXPANSION IN OMRON G5Q-1A4 DC24V THERM 4-20mA 0-10V 0-5V Connect To Zone/VAV Controller With Modular Cable _ AOUT 0-10 VDC Signal WattMaster Part #OE325-01 Relay Expansion Board Typical Wiring For Single Duct Terminal With Modulating Hot Water Heat 0-10 VDC Modulating Hot Water Valve Supplied & Wired By Others COM 24VAC GND + 24 VAC Transformer Supplied & Wired by Others. Size For Required HW Valve Load. PWR GND 0-10 VDC HWV AOUT MADE IN USA WATMASTER CONTROLS INC. SA RELAYS VDE 24VAC 24 VAC Transformer Supplied & Wired by Others. Size For Required Fan Relay Load. COM R3 R4 Fan Relay YS102252 REV 1 ZONE EXPANSION 5A30VDC CHINA 10A250VAC ~ Rc PIC18F4520 AIN STAT COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R1 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE RC R1 R2 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VREF GND ANALOG INPUT Remove Control Board from Snaptrack & Mount Snaptrack on Box ANALOG OUTPUT EXPANSION IN OMRON G5Q-1A4 DC24V THERM 4-20mA 0-10V 0-5V Connect To Zone/VAV Controller With Modular Cable _ AOUT 0-10 VDC Signal R1 24 VAC Fan Relay Supplied & Wired By Typical Wiring For Others. 1 Amp Max. Fan Terminal With Load. WattMaster Part #OE325-01 Relay Expansion Board Modulating Hot Water Heat JOB NAME FILENAME ZCAP-Exp-Mod-Wire-1B.CDR DATE: 08/15/14 PAGE DRAWN BY: B. Crews DESCRIPTION: VAV/Zone Controller Actuator Packages 2 of 6 OE325-01 Expansion Module Wiring Details Figure 42: OE325-01 Expansion Module Wiring VCM-X Component & Systems Wiring 63 Zone Modular & Non-Modular VAV/Zone Controller Wiring Zone Expansion Module Wiring PWR GND AOUT MADE IN USA WATMASTER CONTROLS INC. RELAYS Rc HWV R3 R4 YS102252 REV 1 ZONE EXPANSION 5A30VDC CHINA 10A250VAC ~ R1 PIC18F4520 AIN STAT GND COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE 24 VAC 2 Position HW Valve Supplied & Wired By Others. 1 Amp Max. Load. RC R2 R2 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE ANALOG INPUT Typical Wiring for Single Duct Terminal With 2 Position HW Valve ANALOG OUTPUT PWR EXPANSION IN 24 VAC Transformer Supplied & Wired by Others. Size For Required HW Valve & Fan Relay Load. 24VAC GND COM AOUT 24 VAC Fan Relay Supplied & Wired By Others. 1 Amp Max. Load. MADE IN USA WATMASTER CONTROLS INC. SA RELAYS VDE R1 24 VAC 2 Position HW Valve Supplied & Wired By Others. 1 Amp Max. Load. R4 HWV YS102252 REV 1 ZONE EXPANSION 5A30VDC CHINA 10A250VAC ~ RC R1 R2 Fan Relay R3 PIC18F4520 AIN STAT COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE Rc 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R1 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R2 OMRON G5Q-1A4 DC24V VREF GND ANALOG INPUT WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box VDE WattMaster Part #OE325-01 Expansion Module w/ Modular Cable Supplied by WattMaster Mounted by Others THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster COM SA 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VREF WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box ANALOG OUTPUT EXPANSION IN OMRON G5Q-1A4 DC24V THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster 24 VAC Transformer Supplied & Wired by Others. Size For Required HW Valve Load. 24VAC WattMaster Part #OE325-01 Expansion Module w/ Modular Cable Supplied by WattMaster Mounted by Others Typical Wiring for Fan Terminal With 2 Position HW Valve JOB NAME FILENAME ZCAP-Exp-Mod-Wire-1A.CDR DATE: 01/16/13 PAGE DRAWN BY: B. Crews DESCRIPTION: VAV/Zone Controller Actuator Packages 3 of 6 OE325-01 Expansion Module Wiring Details Figure 43: OE325-01 Expansion Module Wiring 64 VCM-X Component & Systems Wiring Modular & Non-Modular VAV/Zone Controller Wiring Expansion Module Wiring PWR GND AOUT SCR AOUT 0-10 VDC SCR Electric Heat Controller Supplied & Wired By Others MADE IN USA WATMASTER CONTROLS INC. SA RELAYS VDE R3 R4 YS102252 REV 1 ZONE EXPANSION 5A30VDC CHINA 10A250VAC ~ Rc PIC18F4520 AIN STAT GND COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R1 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R2 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VREF ANALOG INPUT WattMaster Part #OE325-01 Expansion Module w/ Modular Cable Supplied by WattMaster Mounted by Others Typical Wiring For Single Duct Terminal With SCR Electric Heat PWR EXPANSION IN GND ANALOG OUTPUT WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box ANALOG OUTPUT EXPANSION IN OMRON G5Q-1A4 DC24V THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster GND GND AOUT SCR AOUT 0-10 VDC MADE IN USA WATMASTER CONTROLS INC. VDE RC R1 24VAC 24 VAC Transformer Supplied & Wired by Others. Size For Required Fan Relay Load. COM R3 R4 Fan Relay YS102252 REV 1 ZONE EXPANSION 5A30VDC CHINA 10A250VAC ~ Rc PIC18F4520 AIN STAT COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R1 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R2 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VREF GND ANALOG INPUT WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box 0-10 VDC SCR Electric Heat Controller Supplied & Wired By Others SA RELAYS OMRON G5Q-1A4 DC24V THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster R1 WattMaster Part #OE325-01 Expansion Module w/ Modular Cable Supplied by WattMaster Mounted by Others 24 VAC Fan Relay Supplied & Wired By Others. 1 Amp Max. Load. Typical Wiring For Fan Terminal With SCR Electric Heat JOB NAME FILENAME ZCAP-Exp-Mod-Wire-1A.CDR DATE 01/16/13: PAGE 4 of 6 DRAWN BY: B. Crews DESCRIPTION: VAV/Zone Controller Actuator Packages OE325-01 Expansion Module Wiring Details Figure 44: OE325-01 Expansion Module Wiring VCM-X Component & Systems Wiring 65 Zone Modular & Non-Modular VAV/Zone Controller Wiring Zone Expansion Module Wiring PWR GND AOUT MADE IN USA WATMASTER CONTROLS INC. RELAYS Rc COM R3 R4 R4 Auxiliary Electric Heat Contactor YS102252 REV 1 ZONE EXPANSION 5A30VDC CHINA 10A250VAC ~ 24 VAC Transformer Supplied & Wired by Others. Size For Required Auxiliary Electric Heat Contactor Load. 24VAC R1 PIC18F4520 AIN STAT GND COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE RC R2 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE ANALOG INPUT C1 24 VAC Auxiliary Electric Heat Contactor Supplied & Wired By Others. 1 Amp Max. Load. Typical Wiring For Single Duct Terminal With Auxiliary Electric Heat ANALOG OUTPUT PWR EXPANSION IN GND AOUT MADE IN USA WATMASTER CONTROLS INC. SA RELAYS VDE 24 VAC Transformer Supplied & Wired by Others. Size For Required Fan Relay & Auxiliary Electric Heat Contactor Load. 24VAC COM R4 Fan Relay R4 YS102252 REV 1 ZONE EXPANSION 5A30VDC CHINA 10A250VAC ~ RC R1 R3 PIC18F4520 AIN STAT COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE Rc 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R1 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R2 OMRON G5Q-1A4 DC24V VREF GND ANALOG INPUT WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box VDE WattMaster Part #OE325-01 Expansion Module w/ Modular Cable Supplied by WattMaster Mounted by Others THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster SA 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VREF WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box ANALOG OUTPUT EXPANSION IN OMRON G5Q-1A4 DC24V THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster R1 WattMaster Part #OE325-01 Expansion Module w/ Modular Cable Supplied by WattMaster Mounted by Others Auxiliary Electric Heat Contactor 24 VAC Fan Relay & Auxilliary Electric Heat Contactor Supplied & Wired By Others. 1 Amp Max. Load. C1 Typical Wiring For Fan Terminal With Auxiliary Electric Heat JOB NAME FILENAME ZCAP-Exp-Mod-Wire-1A.CDR DATE: 01/16/13 PAGE 5 of 6 DRAWN BY: B. Crews DESCRIPTION: VAV/Zone Controller Actuator Packages OE325-01 Expansion Module Wiring Details Figure 45: OE325-01 Expansion Module Wiring 66 VCM-X Component & Systems Wiring Modular & Non-Modular VAV/Zone Controller Wiring Expansion Module Wiring PWR GND AOUT MADE IN USA WATMASTER CONTROLS INC. SA RELAYS VDE 24 VAC Transformer Supplied & Wired by Others. Size For Required Auxiliary HW Valve Load. COM R3 R4 YS102252 REV 1 ZONE EXPANSION 5A30VDC CHINA 10A250VAC ~ Rc PIC18F4520 AIN STAT GND COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE 24VAC R1 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R2 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VREF ANALOG INPUT WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box ANALOG OUTPUT EXPANSION IN OMRON G5Q-1A4 DC24V THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster WattMaster Part #OE325-01 Relay Expansion Board w/ Modular Cable Supplied by WattMaster Mounted by Others HWV 24 VAC 2 Position Auxiliary HW Valve Supplied & Wired By Others. 1 Amp Max. Load PWR GND AOUT MADE IN USA WATMASTER CONTROLS INC. SA RELAYS VDE COM R3 R4 Fan Relay 24 VAC Fan Relay Supplied & Wired By Others. 1 Amp Max. Load. YS102252 REV 1 ZONE EXPANSION 5A30VDC CHINA 10A250VAC ~ Rc PIC18F4520 AIN STAT COMM 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE 24 VAC Transformer Supplied & Wired by Others. Size For Required Fan Relay & Auxiliary Hot Water Valve Load 24VAC R1 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE R2 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VREF GND ANALOG INPUT WattMaster Part # BK000047 Snaptrack Supplied by WattMaster Mounted by Others. Remove Control Board from Snaptrack & Mount Snaptrack on Box ANALOG OUTPUT EXPANSION IN OMRON G5Q-1A4 DC24V THERM 4-20mA 0-10V 0-5V Connect To VAV/Zone Controller Using Modular Cable Supplied By WattMaster Typical Wiring For Single Duct Terminal With Two Position Auxiliary Hot Water Heat R1 WattMaster Part #OE325-01 Relay Expansion Board w/ Modular Cable Supplied by WattMaster Mounted by Others HWV Typical Wiring For Fan Terminal With Two Position Auxiliary Hot Water Heat 24 VAC 2 Position Auxiliary HW Valve Supplied & Wired By Others. 1 Amp Max. Load JOB NAME FILENAME ZCAP-Exp-Mod-Wire-1A.CDR DATE: 01/16/13 PAGE DRAWN BY: B. Crews DESCRIPTION: VAV/Zone Controller Actuator Packages 6 of 6 OE325-01 Expansion Module Wiring Details Figure 46: OE325-01 Expansion Module Wiring VCM-X Component & Systems Wiring 67 Zone Modular & Non-Modular VAV/Zone Controller Wiring Zone Slaved Zone Wiring OE520-XX-M, OE736-01, OE742-31 EXPANSION OE267 (PL101824) BYPASS AND SLAVE INTERFACE CARD PAL D'STAT EPROM CLOSE ACTUATOR OPEN GND FDBK 1 LD1 OPEN CLOSE PJ2 FROM ZONE CONTROLLER OE282 PROCESSOR 24 Mhz ADDRESS OFF LD2 93C66 EEPROM SPACE SENSOR ON CLOSE TB2 OPEN 485 DRV TB1 MODULAR CABLE 0 GND REC PJ1 TO ACTUATOR LOW(VVT) VELOCITY BYPASS AND SLAVE INTERFACE YS101824 POWER / COMM WDOG AIRFLOW PWR STAT HI(VAV) MADE IN USA WATTMASTER CONTROLS INC HZ000095 OE523, OE738, OE282-03 SLAVED- ZONE ACTUATOR #2 (WHEN USED) 0 1 OE523, OE738, OE282-03 MODULAR CABLE SLAVED-ZONE ACTUATOR #1 0 1 OE282 OE282 MODULAR CABLE BYPASS AND SLAVE INTERFACE YS101824 BYPASS AND SLAVE INTERFACE YS101824 (PL101824) BYPASS AND SLAVE INTERFACE CARD PJ1 HZ000095 TO ACTUATOR HZ000095 TO ACTUATOR (PL101824) BYPASS AND SLAVE INTERFACE CARD MODULAR CABLE PJ1 GND TB2 TB2 GND OPEN OPEN OPEN LD2 PJ2 FDBK TB1 TB1 FDBK GND NOT USED FOR THIS APPLICATION FROM ZONE CONTROLLER CLOSE PJ2 CLOSE LD1 OPEN LD2 NOT USED FOR THIS APPLICATION FROM ZONE CONTROLLER CLOSE LD1 CLOSE GND OPEN OPEN CLOSE CLOSE JOB NAME FILENAME ZCAP-ZoneSlaveWire1B.CDR DATE: 08/15/2014 PAGE DRAWN BY: B. Crews DESCRIPTION: VAV/Zone Controller Actuator Packages 1 of 1 OE267 Slaved Zone Damper Wiring Details Figure 47: Slaved Zone Wiring 68 VCM-X Component & Systems Wiring Communication Devices Communication Devices Diagrams VCM-X Component & Systems Wiring 69 Communication Devices System Manager Stand-Alone Wiring 4GB Modular System Manager SD Back View NOTE: For Stand-Alone Installations (No CommLink or MiniLink), All TERM Jumpers Must Be ON. For All Applications With CommLink(s) Or MiniLink(s), All Jumpers Must Be OFF. NOTE: If Desired A Power/Comm Board As Used With The Networked System Can Be Installed And Wired Instead Of Using The Pigtail Cable Wiring Shown Below. See The Networked System Wiring Diagram For Details. Use Supplied Modular Cable With Stripped Ends For Connection To Terminal Block And Transformer T SHLD R WHITE (T) DRAIN WIRE (SHLD) BLACK (R) RED (24 VAC) BROWN (GND) GREEN (GND) Controller Board Class 2 Transformer Rated For 6 VA Minimum JOB NAME FILENAME O-ModSystemMgr-ModPigtail1E.cdr DATE: 09/23/2013 PAGE BY: S. Olson DESCRIPTION: OE392-12 Modular System Manager 1 of 1 Stand-Alone Wiring Details Figure 48: OE392-12 Modular System Manager Stand-Alone Wiring 70 VCM-X Component & Systems Wiring Communication Devices 4GB System Manager Modular Cable Pigtail - Wiring Detail OE392-12 Modular System Manager SD Back of Front Cover HZ000121 Modular Pigtail Cable Supplied With System Manager Handy Box, Conduit, Fittings, Wire Nuts, Butt Splices Etc., (By Others) C VA (24 D RE ) (G GR EE BLACK (R) N N OW BR T SHLD R WHITE (T) D) N( 2-Conductor Shielded 18-Gauge Communications Wire GN D) LINE VOLTAGE Controller Board Drain Wire (Shld) Class 2 Transformer Rated For 6 VA Minimum (By Others) LINE VOLTAGE System Manager Wiring Details For Using The Pigtail JOB NAME DATE: 05/18/15 By: S. Olson FILENAME Notes: 1.) All wiring to be in accordance with local and national electrical codes and specifications. 2.) All modular power/comm cables are to be WattMaster part number PCC-xx or PCCE-xx cables. SysMgrPigtail1C.CDR DRAWN BY: B. Crews DATE: 01/16/13 PAGE DESCRIPTION: OE392-12 Modular System Manager 1 of 1 Component Wiring Diagram Figure 49: OE392-12 Modular System Manager SD Cable Pigtail - Wiring Detail VCM-X Component & Systems Wiring 71 Communication Devices System Manager Networked Wiring 4GB Modular System Manager SD Back View All Modular Power/Comm Cables Are To Be WattMaster Part Number PCC-xx Or PCCE-xx Cables. NOTE: For Stand-Alone Installations (No CommLink or MiniLink), All TERM Jumpers Must Be ON. For All Applications With CommLink(s) Or MiniLink(s), All Jumpers Must Be OFF. Power/Comm Cables To Power/Comm Distribution Board, MiniLink Polling Device Or VAV/Zone Controllers On Local Loop. JOB NAME FILENAME O-ModSystemMgr-ModConnect-1C.cdr DATE: 05/15/15 PAGE BY: S. Olson DESCRIPTION: OE392-12 Modular System Manager 1 of 1 Networked Wiring Details Figure 50: OE392-12 Modular System Manager SD Networked Wiring 72 VCM-X Component & Systems Wiring Communication Devices Modular Service Tool Connections Male DIN Connector Female DIN Connector Typical Controller Board Connector Cable RS-485 Port EBC E-BUS Port The Modular Service Tool Can Be Connected To A Unit Controller Or VAV/Zone Controller By Plugging One End Of The Supplied Cable Into the Modular Service Tool DIN Connector And The Other End Into The DIN Connector On The Controllers. Modular Service Tool SD Be Sure The Modular Service Tool Is Connected To The Supplied Power Pack Or Has Fresh Batteries Installed Before Attempting Programming Of The Controller. Be Sure The Power Is Turned Off On The Modular Service Tool Before Connecting The Cable To The Controller. SD Memory Card Power On Button JOB NAME FILENAME G-ModServiceTool-SD-1A.cdr DATE: 05/15/15 PAGE BY: S. Olson DESCRIPTION: OE391-12 Modular Service Tool 1 of 1 Connection Diagram Figure 51: OE391-12 - Modular Service Tool SD Connections VCM-X Component & Systems Wiring 73 Communication Devices To T Terminal On VCM-X Controller To S Terminal On VCM-X Controller To R Terminal On VCM-X Controller System Manager TS II to VCM-X E-BUS Controller Wiring To (24 VAC) Transformer - BLACK (R) BARE (S) WHITE (T) To (24 VAC) Transformer + BROWN (GND) RED (24 VAC) WHITE (T) BARE (S) BLACK (R) BROWN (GND) RED (24 VAC) 24 VAC Transformer 5 VA Minimum R S Run 2 Conductor Twisted Pair W/Shield Cable. WattMaster WR-LL-WG-18 Cable Or Equivalent From System Manager TS To VCM-X Controller T Line Voltage + 1002 1002 1002 R16 R13 C9 .1uF GND OPT4 R7 OPT3 OPT1 C7 OPT2 R1 1002 C12 C15 1002 SW1 OFF .1uF .1uF C25 R10 C1 .1uF 1002 C10 MADE IN USA 66.000Mhz R8 1002 .1uF .1uF .1uF R20 C23 R34 C11 WattMaster Controls, Inc WQVGA Graphical Interface YS102178 R4 C14 .1uF C26 .1uF .1uF .1uF X3 .1uF C13 Run 2 Conductor 20 Ga. Minimum Cable From System Manager TS Terminals To 24 VAC Transformer. NOTE: Be Sure All Dip Switches Are Off. R T 1002 1002 R2 C41 1002 R41 C36 1002 D11 R32 L4 1002 1002 L1 U9 C30 C27 U10 R18 1002 1002 C28 .1uF 1002 1002 C2 C3 1002 V1 1002 R39 LTC3824 R11 1002 R49 C24 R23 .1uF R44 + 330uF 1002 U13 .1uF T 330uF 50V .1uF 1002 1002 1002 .1uF 1002 D12 1002 1002 R S 1002 .1uF 1002 R37 U11 Q2 R35 1002 1002 R15 C29 R31 .1uF D2 1002 R46 R43 R25 C31 R19 R28 R33 C32 R30 R47 C4 C50 C51 J3 1002 .1uF C5 L5 2.5V C40 .1uF R48 .1uF C39 3.3V D1 .1uF R40 R42 5V TERM 8.00Mhz 1002 1002 R21 C34 R17 R26 C45 X2 1002 SERIAL # 1002 R14 RTC CAL J1 .1uF R12 .1uF C16 .1uF 1002 C18 .1uF 1002 .1uF .1uF C35 .1uF 1002 R29 .1uF C8 1002 C17 C6 R36 R6 R5 .1uF R27 1002 R9 C19 .1uF R24 1002 1002 5V 1002 C20 R22 1002 1002 R45 TERM OE392-10 System Manager TS II - Back View RS-485 COMMUNICATION LOOP. WIRE “R” TO “R”, “T” TO “T” “SHLD” TO “SHLD” RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC RELAY COMMON FAN RELAY 2 RELAY 3 RELAY 4 WHITE (T) BARE (S) RELAY 5 T S BLACK (R) NOTE: For Stand-Alone Installations (No CommLink or MiniLink), Both TERM Jumpers Must Be ON. For All Applications With CommLink(s) Or MiniLink(s), Both Jumpers Must Be OFF. AAON No.: V07150 VCM-X MODULAR E-BUS CONTROLLER Orion No.:OE332-23E-VCMX-MOD-A AI1 = SPC (SPACE TEMPERATURE SENSOR) AI2 = SAT (SUPPLY AIR TEMPERATURE SENSOR) AI3 = RAT (RETURN AIR TEMPERATURE SENSOR) AI4 = OAT (OUTDOOR AIR TEMPERATURE SENSOR) AI5 = SUCTION PRESSURE SENSOR (FROM EXP. MODULE) AI7 = SPACE TEMPERATURE SENSOR SLIDE ADJUST OR VOLTAGE RESET SOURCE A01 = ECONOMIZER (2-10 VDC OUTPUT) A02 = SUPPLY FAN VFD (0-10 VDC OUTPUT) R E-BUS CONNECTOR ANALOG INPUT JUMPER SETTINGS AI1 SET AI3 AI5 AI4 SET AI7 AI3 SET AI4 AI2 SET AI2 LED BLINK CODES LED NAME STATUS1 STATUS2 AI1 THERM 4-20mA 0-10V 0-5V OAT FAIL 2 AI2 THERM 4-20mA 0-10V 0-5V SPC FAIL 3 2 MODULE ALARM 4 2 MECH COOL FAIL 1 AI3 THERM 4-20mA 0-10V 0-5V THERM 4-20mA 0-10V 0-5V DIRTY FILTER THERM 4-20mA 0-10V 0-5V HIGH SAT AI5 CONT. TEMP HEAT FAIL 4 4 PUSH BUTTON OVR 1 5 AI7 THERM 4-20mA 0-10V 0-5V AI1 AI4 NORMAL OPERATION SAT FAIL 1 1 2 2 3 MECH HEAT FAIL 2 3 FAN PROOF FAIL 3 3 4 3 EMERGENCY SHUTDOWN 5 3 LOW SAT 1 4 2 CONT. TEMP COOL FAIL AI5 SET ZONE OVR OUTPUT FORCE ACTIVE AI7 SET ANALOG INPUT JUMPER SETTINGS MUST BE SET AS SHOWN FOR PROPER OPERATION STATIC PRESSURE 0 WattMaster Label #LB102073-01-A Rev.: 1A 3 4 4 2 5 0 6 JOB NAME 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED 2 IC EXPANSION 2 IC DIGITAL SENSOR FILENAME SysMgrTS-VCM-X-1A.CDR DATE: 01/18/13 OE332-23E-VCMX-MOD VCM-X E-BUS Controller - Front View PAGE 1 of 1 DRAWN BY: B. Crews; S. Olson DESCRIPTION: OE392-10 System Manager TS II VCM-X Connections & Wiring Figure 52: OE392-10 System Manager TS II to VCM-X E-BUS Controller Wiring 74 VCM-X Component & Systems Wiring Communication Devices GREEN (GND) RED (24 VAC) 1002 1002 R16 1002 1002 R13 OPT3 OPT4 C41 C36 D11 1002 1002 L4 R32 R31 1002 L1 C35 C30 C27 U10 R18 1002 1002 C28 U11 Q2 1002 U9 1002 C2 C3 1002 1002 330uF .1uF R39 LTC3824 R11 R25 C31 R19 R28 R33 C32 R30 R49 R44 330uF 50V 1002 .1uF 1002 R15 C29 .1uF 1002 C24 1002 1002 R37 + .1uF 1002 D12 T .1uF R S 1002 1002 1002 1002 R23 R35 1002 U13 1002 R46 R43 .1uF V1 .1uF C4 J3 R48 C5 C50 C51 .1uF D1 R47 .1uF 2.5V C40 .1uF 1002 L5 C39 1002 1002 C34 8.00Mhz R40 R42 3.3V .1uF 1002 R21 5V C45 X2 1002 1002 J1 1002 RTC CAL C18 C16 TERM .1uF R12 .1uF R14 T .1uF 1002 .1uF D2 C17 .1uF R17 R26 .1uF 1002 .1uF C8 1002 R SERIAL # R2 .1uF C6 R36 1002 1002 R27 1002 R6 R5 1002 GND 5V .1uF R29 OPT2 C22 R9 C19 .1uF .1uF C20 R24 1002 C7 .1uF 1002 1002 Power/Comm Pigtail Cable From VAV/Zone Controller Actuator Package Or Power/Comm Distribution Board OPT1 C15 1002 R7 1002 R22 OFF .1uF .1uF C25 R10 C1 .1uF R8 66.000Mhz 1002 C12 R1 1002 .1uF 1002 SW1 R34 C9 MADE IN USA R41 C10 .1uF .1uF .1uF .1uF .1uF R20 C23 NOTE: Be Sure All Dip Switches Are Off. WattMaster Controls, Inc WQVGA Graphical Interface YS102178 R4 C14 .1uF C26 + .1uF X3 BROWN (GND) BARE (S) WHITE (T) T C13 R S C11 BLACK (R) System Manager TS II to VAV/Zone Controller Wiring R45 TERM OE392-10 System Manager TS II Back View NOTE: For Stand-Alone Installations (No CommLink or MiniLink), Both TERM Jumpers Must Be ON. For All Applications With CommLink(s) Or MiniLink(s), Both Jumpers Must Be OFF. JOB NAME FILENAME SysMgrTS-VAV-1A.CDR DATE: 01/18/13 DRAWN BY: B. Crews; S. Olson PAGE DESCRIPTION: 1 of 1 OE392-10 System Manager TS II VAV/Zone Controller Connections & Wiring Figure 53: OE392-10 System Manager TS II to VAV/Zone Controller Wiring VCM-X Component & Systems Wiring 75 Communication Devices CommLink 5 Connections & Wiring NOTE: A CommLink Is Always Required With A Networked Multiple Loop System. It Is Used For Alarm Callout, Remote Computer Connection, or Direct Computer Connection To The System Is Desired. An IP Module Is Only Required If E-Mail Alarm Notification Or Remote Computer Connection Is Required. DIAG LOOP ACT LNK GND Serial # 24V T (-) CommLink 5 Communications Interface R (+) COMPUTER USB HIGH LOW 10/100 ETHERNET MULTIPLE SINGLE When Used With MiniLink, Switch Should Be Set To Multiple. SHLD WARNING! If You Are Using The IP Module With Your CommLink, Do Not Have Your Ethernet Connection And USB Connection Connected At The Same Time. This Could Cause Unreliable Communications. BAUD 485 LOOP POWER 24 VAC Power Optional Items Not Required For CommLink-Only Installations. 18 Gauge 2 Conductor With Shield (Not Included) See Note 1 Connect To Controller As Required By Your Specific System Wiring Instructions. USB Cable (Included). Connect This Cable To Your Computer USB Port For Direct Connection To The CommLink 5. 120 to 24 VAC Power Pack (Included) Connect To 120/1/60 Duplex Receptacle (By Others) Optional - Prefabricated 10 Ft. Long CAT5 Ethernet Cable (Included With Optional OE41502 IP Module Kit). Connect To A 10/100 Base-T Ethernet Router On Your LAN. If A Longer Ethernet Cable Is Required, You Will Need To Obtain (From Others) And Install An Ethernet Cable Of The Required Length For Your Installation. If Desired A 24 VAC Transformer (Not Included) Rated At 12 VA Minimum May Be Used Instead Of The Supplied Power Pack. Use 18 Gauge Minimum 2 Conductor Wire Between The Transformer & CommLink 5 Terminals NOTES: 1) For Direct Connection Via USB, Your Computer Must Have An Unused USB Port Available. Drivers For Your USB Port Are Provided On A CD Supplied With The CommLink 5. Please Follow The Directions In The CommLink 5 Technical Guide To Install And Configure The USB Drivers. JOB NAME 2) The CommLink 5 Cannot Communicate With The Control System Through Its Ethernet Port And USB Port At The Same Time. 3) All Wiring Must Conform To Applicable Federal, State & Local Electrical Wiring Codes. FILENAME CommLink5-Setup1A.cdr DATE: 01/18/13 PAGE BY: B. Crews, S. Olson DESCRIPTION: OE361-13 CommLink 5 1 of 1 Wiring & Connection Diagram Figure 54: OE361-13 CommLink 5 Computer Connection and Wiring 76 VCM-X Component & Systems Wiring Communication Devices IP Module Installation Instructions IP-Module General Installation Instructions Installing the OE415-02 IP Module into the CommLink 5 Round Pin Hole IP Module Socket Location Pin - Typ. R T SH 24VAC GND R rt N R NT LA IX ON Po Wi 11 -EE ev.A -6B R 1 W2 06 -89 -4A -20 00 0-01 00 01 0 50 7 WP 72,4 n 49 aiwa t. Pa in T de Ma IP Module (Part Of OE415-02 IP Module Kit). Used When TCP/IP LAN Or Internet Communications With The Control System Is Desired. IP Module Installation Instructions: First Remove The Enclosure Screws That Hold The Top And Bottom Of The CommLink Enclosure Together. Remove The Top Half Of The Enclosure To Access The Circuit Board And IP Module Socket. PIC 32 Insert The IP Module’s Guide Pins Into The Round Pin Holes On The CommLink Circuit Board As Shown. When The Pins Are Properly Aligned, Press Down On The IP Module Firmly To Seat It Into Its Socket. After Making Sure The IP Module Is Firmly Seated, Replace The CommLink Cover And Secure The Enclosure Halves Back Together With The Enclosure Screws That Were Previously Removed. Follow The Instructions In This Guide For Installing The IP Module Software And Configuring The IP Module For Your Control System. JOB NAME FILENAME IP-ModInstall1A.CDR DATE: 01/18/13 PAGE 1 of 1 BY: S. Olson DESCRIPTION: CommLink 5 IP Module Installation Wiring & Connection Diagram Figure 55: OE415-02 IP Module Installation Instructions VCM-X Component & Systems Wiring 77 Job-Site Laptop Computer (By Others) with Prism 2 Software Installed Type A USB Cable End USB Cable Assembly (Supplied With CommLink 5) ACT LNK LOOP COMPUTER USB BAUD 485 LOOP POWER Serial # Connect Type A Cable End To USB Port On Desktop Or Laptop Personal Computer & Type B End To USB Port On CommLink 5. NOTE: USB Drivers Supplied With The CommLink 5 Must Be Installed On Your Computer Before The CommLink 5 Can Be Used Type B USB Cable End DIAG 10/100 ETHERNET MULTIPLE SINGLE CommLink 5 (Back View) HIGH LOW 485 LOOP Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R R (+) T SHLD R CommLink 5 (Front View) GND T G R SHLD Note: Set CommLink Internal Switch To “Multi” When MiniLink PD Is Used Otherwise Switch Must Be Set To “Single” T (-) 78 24V Optional Computer Connection Diagram FILENAME 1 of 1 PAGE BY: S. Olson Wiring & Connection Diagram VCM-X Job Site Computer Only DESCRIPTION: DATE: 01/04/13 O-VCMX-JS-Comp-Only-1A.cdr JOB NAME Connect To MiniLink PD Network Terminals (When Used) Otherwise Connect to VCM-X E-BUS Controller Communications Terminal 110 VAC To 24 VAC Power Pack (Supplied With CommLink 5) Communication Devices On-Site Computer Connections & Wiring Figure 56: On-Site Computer Connection VCM-X Component & Systems Wiring VCM-X Component & Systems Wiring DIAG ACT LNK 10/100 ETHERNET LOOP COMPUTER USB HIGH LOW BAUD T (-) SHLD GND R (+) T G R 485 LOOP POWER 24V Serial # T SHLD R 1 of 1 PAGE BY: S. Olson Wiring & Connection Diagram VCM-X IP Module Job Site Computer Connections DESCRIPTION: DATE: 01/04/13 JOB NAME Connect To MiniLink PD Network Terminals (When Used) Otherwise Connect to VCM-X E-BUS Controller Communications Terminal 110 VAC To 24 VAC Power Pack (Supplied With CommLink IV) O-VCMX-IP-Mod-Computer-1A.CDR FILENAME Typical Terminal Blocks. All Wiring To Be T To T, SHLD (G) To SHLD (G) & R To R (Back View) MULTIPLE SINGLE CAT5 Crossover Ethernet Cable (Supplied With IP Module) Used For Setting IP Address On CommLink 5. See IP Module Technical Guide Supplied With IP Module For Software & Installation Details. Remove Crossover Cable After Setting IP Address And Connect CommLink 5 To Firewall, Proxy, Router Or Modem (By Others) As Desired Using Standard CAT5 Ethernet Cable (By Others) Firewall/Proxy/Router/Modem (By Others) Personal Computer (By Others) with Prism 2 Software Installed CAT5 Ethernet Cable (By Others) CommLink 5 w/IP Module Installed (Front View) CAT5 Ethernet Cable (By Others) 485 LOOP CAT5 Ethernet Cable (By Others) To Next Node On Building LAN Or WAN Optional Computer Connection Diagram Using IP-Module For Job-Site Location Connection Communication Devices Remote Job-Site Computer Connections & Wiring Figure 57: Remote Job-Site Computer Connection 79 80 NETWORK STAND ALONE USB Cable Supplied With USB-Link Connect Type B Cable End To USB Port On USB Link. Communication Switch Must Be Set To Stand Alone Or Network Depending On Your Installation. USB-Link 2 Communication Speed Switch Must Be Set To Low or High Speed Depending on Your Controller’s Baud Rate. Connect Mini-DIN Cable End To Mini-DIN Port On USB-Link. Connect The USB-Link Mini-DIN Cable To The Female Mini-DIN Plug Connector On Controllers That Are Supplied With Them. NOTE: This Allows Communications With All Controllers That Are Connected To The System. See Note 1. Mini-DIN Cable Supplied With USBLink Computer (By Others) With Prism II Software Installed VCM-X Unit Controller Controller With Mini-DIN Plug 24 VAC (8 VA) T SHLD R PL101905 Adapter Supplied With USB-Link T SHLD R FILENAME 1 of 1 PAGE BY: S. Olson Wiring & Connection Diagram VCM-X Job Site USB-Link 2 DESCRIPTION: DATE: 01/04/13 O-VCMX-JS-USBLINK2-1A.CDR JOB NAME Even Without The EPROM Upgrade You Can Still View A Single Controller Using Prism II. To Do This You Must First Disconnect The Communication Loop From The Controller Your USB-Link Is Plugged Into. Set The USB-Link Communication Switch To Stand Alone, Set The Type Of CommLink In Prism II To USB Link Stand Alone, And Cycle Power By Disconnecting And Reconnecting the USB Power Supply Cable. Notes: 1. For Networked Systems, In The Event That You Have A CommLink II or CommLink III And Have An EPROM Software Version Earlier Than 3.15 Installed In The CommLink, Or Your MiniLink Has An EPROM Software Version Earlier Than 3.14, You Will Need An EPROM Upgrade Before You Can View All Controllers On Your System. Contact WattMaster Technical Support For An EPROM Update. If You Have A CommLink IV This WIll Not Be A Problem. Use The PL101905 Adapter And Wire To A Terminal Block To Connect The USB-Link To The Local Communications Loop On Boards That Don’t Have A Female Mini-DIN Plug Connection. NOTE: This Allows Communications With All Controllers That Are Connected To The System. See Note 1. Mini-DIN Cable Connect Type A Cable End To USB Port On Desktop Or Laptop Personal Computer. NOTE: USB Drivers Supplied With The USBLink 2 Must Be Installed On Your Computer Before USB-Link 2 Can Be Used. Line Voltage PL101904 Adapter Supplied With USB-Link Use The PL101904 Adapter To Plug In To A Terminal Socket And Connect The USB-Link On Boards That Don’t Have A Female Mini-DIN Plug Connection. NOTE: This Only Allows Communications With The Board It Is Connected To. Mini-DIN Cable Optional USB-Link 2 Connection Diagram Communication Devices USB-Link 2 Computer Connections & Wiring WARNING OBSERVE POLARITY Figure 58: Computer Connections Using USB-Link 2 VCM-X Component & Systems Wiring U12 GND R27 0-10V OFF=0-5V THERM 0-10V 4-20mA Not Used R25 R26 24VAC P4 LD6 R1 1 U15 LOCAL LOOP PROC. DRIVER LOOP DRIVER LD5 NETWORK DRIVER NETWORK LOOP CX14 R LD4 U6 P2 D4 CX2 VREF Note: All Communication Wiring Not Utilizing Modular Cable Assemblies Should Be Wired Using 18 Ga. Min. 2 Conductor Twisted Pair With Shield Belden #82760 Or Equivalent. RN3 RN2 CX1 CX6 ADD MiniLink PD To Be Connected To CommLink. U7 CX7 C9 U11 R3 Connect To P3 or P5 Connector On Previous Minilink PD SW1 R30 R29 R28 X2 YS101900PMINILINK POLLING DEVICE REV. 1 Communication Wiring To Be Wired T to T, SHLD (G) to SHLD (G) & R to R U10 HVAC Unit CommLink Controller Terminals Terminals (See Note 3) Only One SHLD Power/Comm Board “IN” Modular Connector (See Note 3) Rated For 6 VA Load Minimum 24 VAC Class 2 Transformer C11 THERM 4-20mA AIN2 U13 R4 V1 R31 C8 AIN1 +5V D1 R24 C3 C1 Controller Address Switch ADD 1 2 4 8 16 32 FILENAME 1 of 2 PAGE DRAWN BY: DESCRIPTION: B. Crews Component Wiring Diagram OE364-22 MiniLink Polling Device DATE: 02/03/04 O-MiniLinkPolDevWr1A.CDR JOB NAME 3) Connection To The Power/Comm Board And/Or Other MiniLink PDs Can Be Made By Using The Local Loop Modular Connector As Shown On Page 1 Or By Using 2 Conductor With Shield Communication Wires As Shown On Page 2. Connections To The HVAC Unit Controller Must Be Made By Using 2 Conductor With Shield Communication Wires Only. 2.) All Modular Power/Comm Cables Are To Be WattMaster Part Number PCC-XX Or PCCE-XX Cables. 1.) All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. Notes: Caution Disconnect All Communication Loop Wiring From The MiniLink PD Before Removing Power From The MiniLink PD. Reconnect Power And Then Reconnect Communication Loop Wiring. Note: The Power To The MiniLink PD Must Be Removed And Reconnected After Changing The Address Switch Settings In Order For Any Changes To Take Effect. Address Switch Shown Is Address Switch Shown Is Set For Address 1 Set For Address 13 The Address For Each MiniLink PD Must Be Unique To The Other MiniLink PDs On The Network Loop And Be Between 1 and 60 Connect To P3 or P5 Connector On Next Minilink PD C10 This Switch Should Be In The OFF Position As Shown D Line Voltage D5 C7 TB2 POWER GND EPROM U3 TB1 CX3 24VAC CX2 AIN 2 RAM U4 LED 2 AIN 1 CX13 T CX15 COMM IN U5 CX4 LED 1 T U2 CX5 RV1 SHLD C3 C1 PROCESSORPBOARD YS101818P552 GND R2 CX1 SHLD WDOG PHILIPS X1 R U14 485 LOOP T G R R CX6 U1 C2 P1 VCM-X Component & Systems Wiring T TB3 P3 P5 D AD 1 2 4 8 16 32 AD TB4 U1 OFF U6 C4 MiniLink Polling Device - Wiring Using Power/Comm Cables Communication Devices MiniLink Polling Device Wiring Using Modular Connectors Figure 59: OE364-22 MiniLink Polling Device Wiring Using Modular Connectors 81 X1 U12 R27 0-10V OFF=0-5V AIN2 THERM 0-10V 4-20mA Not Used CX15 P4 LD6 1 LOCAL LOOP PROC. DRIVER LOOP DRIVER LD5 NETWORK DRIVER NETWORK LOOP SHLD R RN3 R30 R29 R28 X2 X1 R3 ADD Connect To Previous MiniLink PD TB4 Terminal Or CommLink Terminals C3 C10 C1 CX1 CX6 This Switch Should Be In The OFF Position As Shown 1 2 4 8 16 32 Caution Disconnect All Communication Loop Wiring From The MiniLink PD Before Removing Power From The MiniLink PD. Reconnect Power And Then Reconnect Communication Loop Wiring. Note: The Power To The MiniLink PD Must Be Removed And Reconnected After Changing The Address Switch Settings In Order For Any Changes To Take Effect. Controller Address Switch Address Switch Shown Is Address Switch Shown Is Set For Address 1 Set For Address 13 The Address For Each MiniLink PD Must Be Unique To The Other MiniLink PDs On The Network Loop And Be Between 1 and 60 ADD Connect To TB4 Terminals On Next Minilink PD T SHLD R 2 of 2 PAGE DRAWN BY: DESCRIPTION: B. Crews Component Wiring Diagram OE364-22 MiniLink Polling Device DATE: 02/03/04 O-MiniLinkPolDevWr1A.CDR FILENAME 3) Connection To The Power/Comm Board And/Or Other MiniLink PDs Can Be Made By Using The Local Loop Modular Connector As Shown On Page 1 Or By Using 2 Conductor With Shield Communication Wires As Shown On Page 2. Connections To The HVAC Unit Controller Must Be Made By Using 2 Conductor With Shield Communication Wires Only. JOB NAME 2.) All Modular Power/Comm Cables Are To Be WattMaster Part Number PCC-XX Or PCCE-XX Cables. 1.) All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. Notes: All Communication Wiring To Be Wired T to T, SHLD (G) to SHLD (G) & R to R SW1 SHLD Only One MiniLink PD To Be Connected To CommLink. C9 U11 T R26 CX2 Note: All Communication Wiring Not Utilizing Modular Cable Assemblies Should Be Wired Using 18 Ga. Min. 2 Conductor Twisted Pair With Shield Belden #82760 Or Equivalent. HVAC Unit Controller Terminals (See Note 3) LD4 RN2 CX7 YS101900PMINILINK POLLING DEVICE REV. 1 R Power/Comm Board “IN” Terminals (See Note 3) Rated For 6 VA Load Minimum 24 VAC Class 2 Transformer C11 THERM 4-20mA AIN1 C8 U6 U10 U7 D Line Voltage D5 C7 U15 VREF R4 V1 R31 R25 24VAC POWER D4 TB1 CX13 LED 2 GND D1 R24 LED 1 +5V EPROM U3 24VAC CX3 GND RAM U4 TB2 CX4 AIN 1 CX2 AIN 2 U5 GND U13 R1 U2 CX5 RV1 SHLD C3 C1 PROCESSORPBOARD YS101818P552 T CX14 T TB3 R2 SHLD WDOG CX1 X1 R U14 485 LOOP T G R R CX6 PHILIPS T P3 P5 D AD 1 2 4 8 16 32 AD TB4 U1 OFF U6 U1 C2 P1 82 C4 MiniLink Polling Device - Wiring Using Standard Communication Wire Instead Of Power/Comm Cables Communication Devices MiniLink Polling Device Wiring Using Wire Terminals Figure 60: OE364-22 MiniLink Polling Device Wiring Using Wire Terminals VCM-X Component & Systems Wiring Communication Devices Power/Comm Board Wiring For Local Loops WARNING! DO NOT GROUND THE 24V TRANSFORMER THAT IS TO BE USED WITH THE POWER/COMM BOARDS. GROUNDING OF THE TRANSFORMER WILL DAMAGE THE POWER/COMM BOARD AND ALL BOARDS CONNECTED TO IT. A SEPARATE TRANSFORMER MUST BE USED FOR EACH POWER/COMM BOARD. NO EXCEPTIONS. DO NOT CONNECT ANY OTHER DEVICES TO THE TRANSFORMER USED FOR THE POWER/COMM BOARD! Power/Comm Cable From Other Power/Comm Board, System Manager, Or Modular VAV/Zone Controller On Local Loop If This Is The First Power/Comm Board On The Local Loop, No Connection Is Required. See Note 2. Connect To Modular VAV/Zone Controller If This Is First Power/Comm Board On Local Loop - Otherwise No Connection Is Required. See Note 2. Line Voltage Local Loop RS-485 9600 Baud 24VAC 24VAC Transformer (By Others) See System Configuration Installation & Commissioning Section Of This Manual For Detailed Sizing Information 4 Amp Slow Blow Fuse All Comm Loop Wiring Is Straight Thru T SH R T SH R T SH R T SH R COMMP IN TB1 P2 TB2 C1 LD1 T SHLD R 25 F1 4A V1 R1 POWER & COMM DIST. BOARD YS101856 REV. 0 POWER D1 P5 P4 P3 P1 No MinLink PDs Can Be Connected To The Same Power/Comm Board(s) That Are Used To Supply Power And Communications For Modular VAV/Zone Controllers And System Manager On The Local Loop. 24 VAC CAUTION! POWER & COMM OUT Note: Diagram Shown Is For Wiring Of Power/Comm Board When Used For Connecting Local Loop Devices Such As Modular VAV/Zone Controllers, System Manager(s) and Other Power/Comm Boards. See Page 2 Of This Drawing For Wiring When Power/Comm Board Is Used For Connection Of MiniLink Polling Devices On The Network Loop. Local Loop RS-485 9600 Baud Power/Comm Cable To Other Power/Comm Board(s), System Manager, Or Modular VAV/Zone Controllers On Local Loop Only. JOB NAME Notes: 1.) All wiring to be in accordance with local and national electrical codes and specifications. 2.) All modular power/comm cables are to be WattMaster part number PCC-xx or PCCE-xx cables. All other communication wiring to be 2 conductor twisted pair with shield (Belden #82760 or equivalent). FILENAME O-Pwr-CommWire1A.CDR DATE: 02/11/2004 PAGE DRAWN BY: B. Crews DESCRIPTION: OE365-01 Orion Power/Comm Board 1 of 2 Local Loop Wiring Diagram Figure 61: OE365-01 Power/Comm Board Wiring When Used For Local Loop Devices VCM-X Component & Systems Wiring 83 Communication Devices Power/Comm Board Wiring - When Used For Network Loop Devices Comm/Power Cable From Other Power/Comm Board Used For Connecting MiniLink PDs Or Previous MiniLink PD On Network Loop. If This Is The First Power/Comm Board On The Network Loop, This Power/Comm Cable Connection Is Not Required. Instead Use The 3 Pole Terminal Block Communication Connection As Shown Below And Connect To The CommLink. See Note 2. WARNING! DO NOT GROUND THE 24V TRANSFORMER THAT IS TO BE USED WITH THE POWER/COMM BOARDS. GROUNDING OF THE TRANSFORMER WILL DAMAGE THE POWER/COMM BOARD AND ALL BOARDS CONNECTED TO IT. A SEPARATE TRANSFORMER MUST BE USED FOR EACH POWER/COMM BOARD. NO EXCEPTIONS. DO NOT CONNECT ANY OTHER DEVICES TO THE TRANSFORMER USED FOR THE POWER/COMM BOARD! Use To Connect CommLink When This Is the First Power/Comm Board On The Network Loop. Otherwise No Connection Is Required. See Note 2. All Comm Loop Wiring Is Network Loop RS-485 Straight Thru 192000 Baud T T T T Line Voltage 24VAC SH R 24VAC Transformer (By Others) See System Configuration Installation & Commissioning Section Of This Manual For Detailed Sizing Information 4 Amp Slow Blow Fuse SH R SH R SH R COMMP IN TB1 P2 TB2 C1 LD1 T SHLD R 25 F1 4A V1 R1 POWER & COMM DIST. BOARD YS101856 REV. 0 POWER D1 P5 P4 P3 P1 POWER & COMM OUT No Local Loop Devices (Modular VAV/Zone Controllers, System Manager(s) Etc.) Can Be Connected To The Same Power/Comm Board(s) That Are Used To Supply Power And Communications For MinLink PDs On The Network Loop. 24 VAC CAUTION! Note: Diagram Shown Is For Wiring When Power/Comm Board Is Used For Connection Of MiniLink Polling Devices On The Network Loop. For Wiring Of Local Loop Devices Such As Modular VAV/Zone Controllers, System Manager(s) and Other Power/Comm Boards On The Local Loop See Page 1 Of This Drawing For Wiring . Network Loop RS-485 19200 Baud Connect Power/Comm Cables To Other Power/Comm Distribution Board Or MiniLink PDs On The Network Loop Only. JOB NAME Notes: 1.) All wiring to be in accordance with local and national electrical codes and specifications. 2.) All modular power/comm cables are to be WattMaster part number PCC-xx or PCCE-xx cables. All other communication wiring to be 2 conductor twisted pair with shield (Belden #82760 or equivalent). FILENAME O-Pwr-CommWire1A.CDR DATE: 02/11/2004 PAGE DRAWN BY: B. Crews DESCRIPTION: OE365-01 Orion Power/Comm Board 2 of 2 Network Wiring Diagram Figure 62: OE365-01 Power/Comm Board Wiring When Used For Network Loop Devices 84 VCM-X Component & Systems Wiring Add-On Devices Add-On Devices Diagrams VCM-X Component & Systems Wiring 85 Add-On Devices Lighting Panel Wiring For Standard Lighting Contactors Required VA For Transformer Each Controller = 25VA Max. See Note 1 Caution: If Lighting Contactor Coil Current Draw Is More Than 2 Amps And/Or Does Not Use A 24VAC Coil, A Pilot Duty Relay That Has A Current Draw Of Less Than 2 Amps @ 24VAC Must Be Used To Energize The Lighting Contactor. A Separate Transformer Rated For The Total Lighting Contactor(s)Or Pilot Relay Current Draw Must Always Be Used To Power The Circuit. Light Sensor (Optional) Line Voltage SIG +5V Line Voltage 24V Lighting Contactors Or Pilot Duty Relays (By Others) Light Circuit 4 Light Circuit 5 C2 K2 C3 K3 C4 K4 C5 K5 C6 K6 C7 K7 Override Circuit #1 Override Circuit #2 Override Circuit #3 Override Circuit #4 Override Circuit #5 Override Circuit #6 ANALOG OUTPUTS A1 A2 G EPROM Light Circuit 3 K1 RAM Light Circuit 2 CPU C1 GND GND GND Light Circuit 1 Momentary Pushbuttons (Optional) ANALOG INPUTS +V +V 1 2 3 4 5 6 7 8 G G 24VAC Override Circuit #7 PIN 1 PIN 1 Light Circuit 6 PAL T Light Circuit 7 Note: ! All Circuit Board Contacts Are N.O. ! All Contacts Are Rated For 2 Amps @ 24VAC Pilot Duty Only ! Do Not Apply Any Voltage Greater Than 24VAC SH R T SH R Local Loop RS-485 Communications To Other Controllers On The Local Loop OE310-21-LP Lighting Panel Controller Note: Set-up, Programming And Monitoring Of The Lighting Panel Controller Requires The Use Of A Personal Computer And Prism Software. All Lighting Contactors Must Be Wired For N.C. Operation So That System Fails To Lights On Mode. This Switch Must Be In The ON Position As Shown These Switches Should Be In The OFF Position As Shown ADD The Address For Each Controller Must Be Unique To The Other Controllers On The Local Loop AD 1 2 4 8 16 D D AD Controller Address Switch Address Switch Shown Is Set For Address 1 Address Switch Shown Is Set For Address 13 Caution! Controller Must Have Address Switch Set Between 1 And 60 JOB NAME FILENAME 1.)24 VAC Must Be Connected So That All Ground Wires Remain Common. 2.)All Wiring To Be In Accordance With Local And National Electrical Codes and Specifications. 3.)All Communication Wiring To Be 18 Ga. Minimum, 2 Conductor Twisted Pair With Shield. Belden #82760 Or Equivalent. 4.)It Is Recommended That All Controllers Address Switches Are Set Before Installation. W-LightingPnlStd1.CDR DATE: 05/12/04 PAGE 1 C O N T DRAWN BY: R O L S B. Crews DESCRIPTION: OE310-21-LP Lighting Panel Controller Wiring Using Standard Lighting Relays Figure 63: OE310-21-LP Lighting Panel Controller Wiring 86 VCM-X Component & Systems Wiring Add-On Devices GPC-X Controller Wiring Figure 64: OE332-23-GPCX GPC-X Controller Wiring VCM-X Component & Systems Wiring 87 Add-On Devices GPC-X Controller - Address Switch Setting Figure 65: OE332-23-GPCX GPC-X Controller Addressing 88 VCM-X Component & Systems Wiring Add-On Devices GPC-XP Controller Wiring OE338-23-GPC-XP GPC-XP Controller All Communication Loop Wiring Is Straight Through 24VAC Power For Relay Outputs T To T, R To R, SHLD To SHLD Connect To Next Device On The Local Loop Local Loop RS-485 9600 Baud YS102432 REV 3 RS-485 COMMUNICATION LOOP. WIRE “R” TO “R”, “T” TO “T” “SHLD” TO “SHLD” T- RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC SH www.wattmaster.com TB1 ON BOA COMMLI CONNEC R38 BIN1 D6 D7 D8 R51 D10 BIN8 D13 CUT TO ISOLATE COM FROM GND COM COM COM 0-5v 0-10v COMMON TB2 RELAY 6 RLY 2 = RLY 6 = RELAY 7 RLY 3 = RLY 7 = RELAY 8 RLY 4 = RLY 8 = COMMON RELAY OUTPUTS TB4 AI1 = BI1 = AO1 = AI2 = BI2 = AO2 = AI3 = BI3 = AO3 = AI4 = BI4 = AO4 = AI5 = BI5 = AI6 = BI6 = AI7 = BI7 = AI8 = BI8 = RLY1 RLY2 RLY3 RLY4 COMMON SERIAL # ANALOG OUTPUTS R74 U17 1002 ANALOG INPUT JUMPERS LED BLINK CODES LED NAME AOUT1 STATUS1 STATUS2 0 0 1 2 AOUT2 .1uF AOUT3 C36 R97 Analog Outputs AOUT1 through AOUT4 Provide (4) 0-10 VDC Outputs Configured For The Following: 1. Not Configured 2. Direct Acting Floating Point 3. Reverse Acting Floating Point 4. Direct Acting PID 5. Reverse Acting PID 1002 NORMAL OPERATION SCHEDULE OVERRIDE AOUT4 U19 AOUT 3-4 AI2 AI1 GND AI5 AI3 AI2 NOTES: 1.) ANALOG INPUT JUMPER SETTINGS MUST BE SET FOR YOUR SPECIFIC INPUT DEVICE REQUIREMENT. AI6 AI3 AI7 AI4 AI5 AI6 GND GND AI6 C46 TB6 GND 2.) IT IS RECOMMENDED THAT YOU WRITE THE DESCRIPTION OF THE INPUT, AND/OR OUTPUTS YOU ARE CONNECTING TO THE CONTROLLER IN THE BOXES PROVIDED ABOVE ® USING A PERMANENT MARKER (SHARPIE) FOR FUTURE REFERENCE. AI5 GND GND .1uF STATUS1 AI4 AI8 AI7 STATUS2 EBUS POWER .1uF AI8 GND 1002 1002 1002 GND + 24 VAC 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED USB PORT E-BUS PORT WattMaster Label #LB102095 Rev.: 1C 1002 1002 1002 1002 LOOP BAUD +5V + 24 VDC + 5 VDC GND 1002 1 2 4 8 16 32 1 2 1002 VDC OUTPUTS AI8 +24V 1002 R16 R14 ADD AI7 TB7 VDC OUTPUTS R21 R109 C21 ADDRESS 1002 1002 GND SW1 TB8 C14 .01uF GND 24 VAC Must Be Connected So That All Ground Wires Remain Common. Failure To Do So Will Result In Damage To The Controller 24 VAC 5 VDC & 24VDC Power For Sensors Warning: 2.)All Wiring To Be In Accordance With Local And National Electrical Codes and Specifications. RLY4 RELAY 5 RLY 5 = RLY 1 = AI3 AI4 RLY3 RELAY 4 AOUT 1-2 AI1 AI2 THERM 4-20 mA TB3 Analog Inputs AI1Through AI8 Configured For the Following: 1. Thermistor 10K Ohm Type III Temperature Sensors (Fahrenheit) 2. Thermistor 10K Ohm Type III Temperature Sensors (Celsius) 3. 4 - 20mA User Scaled 4. 0 - 5 vdc User Scaled 5. Wall Sensor Slide Offset 6. Read Global Analog Broadcast from another Controller 7. Communicating Temperature Sensor 8. Communicating Humidity Sensor 9. Communicating Carbon Dioxide NOTES: 1.)24 VAC Must Be Connected So That All Ground Wires Remain Common. 300 300 COM AI1 Jumpers - Typical Jumpers Must Be Set Correctly For The Type Of Input You Require. 300 R61 D12 R59 D11 BIN7 RELAY 3 300 R55 BIN6 RLY2 COMMON 300 300 D9 BIN5 OE338-23-GPC-XP GPC-XP CONTROLLER 300 BIN4 ANALOG INPUTS MADE IN USA RLY1 RELAY 2 300 R41 R43 R47 BIN2 0-5V 0-10V 4-20mA THERM BINARY INPUTS BIN3 Binary Inputs BIN1Through BIN8 Configured for The Following: 1. Not Used 2. Normally Closed Operation 3. Normally Open Operation 4. Read Global Binary 5. Push-Button Override 6. Follow Relay WATTMASTER CONTROLS RELAY 1 R+ CommLink Jumpers Both On = Use On Board CommLink Both Off - Use External CommLink 8 Relay Outputs Are Available For On/Off Control Of Equipment Configured For the Following: 1. Not Configured 2. On Above / Off Below 3. On Above / On Below 4. Off Above / On Below 5. Off Above / Off Below 6. Follow Active Binary Input 7. Follow Inactive Binary Input 8. Follow Relay Output 9. Follow Schedule 10. Ventilation Control 11. Lead Relay for Lead/Lag Control 12. Lag Relay for Lead/Lag Control LOOP COMM Line Voltage 24 VAC Transformer 8 VA Minimum ADDRESS Dipswitch is Used for Setting the Address and Baud Rate. EBC E-BUS Cable Connect to Communicating Sensor USB Cable Connect to Computer with Prism II Software Installed For Stand-Alone Programming 3.)All Communication Wiring To Be 18 Ga. Minimum, 2 Conductor Twisted Pair With Shield. Belden #82760 Or Equivalent. 4.)It Is Recommended That The Address Switch Is Set Before Installation. JOB NAME FILENAME GPCXP-CNTRLWire-1A.CDR DATE: PAGE 1 of 1 12/27/12 DRAWN BY: S. Olson DESCRIPTION: OE332-23-GPC-XP GPC-XP Controller Wiring Figure 66: OE332-23-GPCXP GPC-XP Controller Wiring VCM-X Component & Systems Wiring 89 Add-On Devices GPC-XP Controller Addressing & Baud Rate Selection Caution: Disconnect All Communication Loop Wiring From The Controller Before Removing Power From The Controller. Reconnect Power And Then Reconnect Communication Loop Wiring. Note: The Power To The Controller Must Be Removed And Reconnected After Changing The Address Switch Settings In Order For Any Changes To Take Effect. OE338-23-GPC-XP GPC-XP Controller BAUD RATE SELECTION Baud Communication Setting Switch 7 Switch 8 LOOP COMM YS102432 REV 3 T- RS-485 COMMUNICATION LOOP. WIRE “R” TO “R”, “T” TO “T” “SHLD” TO “SHLD” SH ON BOA COMMLI CONNEC R38 BIN1 D6 RLY1 www.wattmaster.com RELAY 2 RLY2 OE338-23-GPC-XP GPC-XP CONTROLLER RELAY 3 RLY3 RELAY 4 RLY4 300 R41 R43 R47 BIN2 D7 BIN3 D8 D9 R51 BIN5 D10 D12 300 R61 BIN7 300 R59 D11 300 R55 BIN6 300 BIN8 D13 COM CUT TO ISOLATE COM FROM GND COM COM COM 0-5v 0-10v AI1 AI2 RLY 5 = RELAY 6 RLY 2 = RLY 6 = RELAY 7 RLY 3 = RLY 7 = RELAY 8 RLY 4 = RLY 8 = COMMON AI1 = BI1 = AO1 = AI2 = BI2 = AO2 = AI3 = BI3 = AO3 = AI4 = BI4 = AO4 = AI5 = BI5 = AI6 = BI6 = AI7 = BI7 = AI8 = BI8 = AI3 AI4 AI3 AI6 AI4 R74 U17 STATUS1 STATUS2 0 0 1 2 AOUT2 .1uF AOUT3 1002 AOUT4 U19 AI5 GND GND .1uF C46 TB6 GND EBUS POWER AD D 1002 GND + 24 VAC 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED USB PORT E-BUS PORT WattMaster Label #LB102095 Rev.: 1C 1002 1002 1002 1002 1002 LOOP BAUD +5V 1002 1 2 4 8 16 32 1 2 1002 VDC OUTPUTS + 24 VDC + 5 VDC GND 1002 ADD 1002 AI7 AI8 1002 R16 R14 ADDRESS GND +24V R21 R109 C21 D AI8 AD AI7 STATUS2 .1uF VDC OUTPUTS 1 2 4 8 16 32 Baud 0 Baud 1 1 2 4 8 16 32 Baud 0 Baud 1 AOUT1 C36 R97 Address 5 @ 57,600 Baud ADD Address 1 @ 9600 Baud ADD STATUS1 AI6 TB7 CommLink 5 & Stand Alone COMMON 2.) IT IS RECOMMENDED THAT YOU WRITE THE DESCRIPTION OF THE INPUT, AND/OR OUTPUTS YOU ARE CONNECTING TO THE CONTROLLER IN THE BOXES PROVIDED ABOVE ® USING A PERMANENT MARKER (SHARPIE) FOR FUTURE REFERENCE. AI5 AI6 ON RLY4 NOTES: 1.) ANALOG INPUT JUMPER SETTINGS MUST BE SET FOR YOUR SPECIFIC INPUT DEVICE REQUIREMENT. GND GND OFF RLY3 LED BLINK CODES AI4 57600 ANALOG OUTPUTS LED NAME AI2 CommLink IV SERIAL # NORMAL OPERATION SCHEDULE OVERRIDE AI3 AI8 GND RLY2 AI1 AI5 AI7 TB4 AOUT 3-4 AI2 OFF TB2 RELAY OUTPUTS RLY1 1002 ANALOG INPUT JUMPERS OFF COMMON RELAY 5 RLY 1 = AOUT 1-2 AI1 THERM ANALOG INPUTS 4-20 mA TB3 COMMON 300 300 300 BIN4 9600 MADE IN USA RELAY 1 0-5V 0-10V 4-20mA THERM BINARY INPUTS WATTMASTER CONTROLS RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC R+ TB1 1002 GND SW1 TB8 C14 Controller Address Switch .01uF Address Switch Shown Is Set For Address 1 Address Switch Shown Is Set For Address 13 The Address For Each Controller Must Be Unique To The Other Controllers On The Local Loop And Be Between 1 and 59 JOB NAME FILENAME GPCXP-AddressSwitchSet-1A.CDR DATE: PAGE 1 of 1 DRAWN BY: 12/27/12 S. Olson DESCRIPTION: OE332-23-GPC-XP GPC-XP Controller Address & Baud Rate Figure 67: OE332-23-GPCXP GPC-XP Controller Addressing & Baud Rate Selection 90 VCM-X Component & Systems Wiring Add-On Devices GPC-XP Controller On-Board CommLink Setting Caution: Disconnect All Communication Loop Wiring From The Controller Before Removing Power From The Controller. Reconnect Power And Then Reconnect Communication Loop Wiring. Note: The Power To The Controller Must Be Removed And Reconnected After Changing The Address Switch Settings In Order For Any Changes To Take Effect. OE338-23-GPC-XP GPC-XP Controller LOOP COMM YS102432 REV 3 T- WATTMASTER CONTROLS RS-485 COMMUNICATION LOOP. WIRE “R” TO “R”, “T” TO “T” “SHLD” TO “SHLD” SH RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC R+ TB1 www.wattmaster.com ON BOA COMMLI CONNEC BINARY INPUTS R38 BIN1 D6 R41 R43 R47 BIN2 ON-BOARD COMMLINK SETTING D7 BIN3 D8 OE338-23-GPC-XP GPC-XP CONTROLLER 300 R51 Setting D10 BIN6 Use On-Board CommLink D12 300 300 R61 ON BIN7 R59 D11 ON 300 R55 Jumper 2 300 BIN8 D13 COM OFF Use External CommLink CUT TO ISOLATE COM FROM GND OFF COM COM COM 0-5v 0-10v THERM 4-20 mA TB3 ANALOG INPUTS RELAY 2 RLY2 RELAY 3 RLY3 RELAY 4 RLY4 COMMON RELAY 5 300 300 D9 Jumper 1 RLY1 COMMON 300 BIN4 BIN5 MADE IN USA RELAY 1 TB2 RELAY OUTPUTS RLY 1 = RLY 5 = RELAY 6 RLY 2 = RLY 6 = RELAY 7 RLY 7 = RELAY 8 RLY1 RLY 3 = RLY 8 = COMMON RLY2 RLY 4 = TB4 RLY3 AI1 = BI1 = AO1 = AI2 = BI2 = AO2 = AI3 = BI3 = AO3 = AI4 = BI4 = AO4 = AI5 = BI5 = AI6 = BI6 = AI7 = BI7 = AI8 = BI8 = RLY4 COMMON SERIAL # ANALOG OUTPUTS R74 U17 1002 ANALOG INPUT JUMPERS AI1 AI2 AI2 AI4 AI7 STATUS2 0 0 1 2 GND AOUT3 C36 R97 1002 AOUT4 U19 GND AI4 NOTES: 1.) ANALOG INPUT JUMPER SETTINGS MUST BE SET FOR YOUR SPECIFIC INPUT DEVICE REQUIREMENT. AI3 AI4 AI5 AI5 TB6 GND STATUS1 STATUS2 AI7 EBUS POWER .1uF 1002 VDC OUTPUTS AI8 1002 1002 1002 GND 24 VAC POWER ONLY WARNING! POLARITY MUST BE OBSERVED OR THE CONTROLLER WILL BE DAMAGED USB PORT E-BUS PORT WattMaster Label #LB102095 Rev.: 1C 1002 1002 1002 LOOP BAUD + 24 VDC + 5 VDC GND +5V + 24 VAC +24V GND 1002 1 2 4 8 16 32 1 2 1002 VDC OUTPUTS 1002 R16 R14 ADD 1002 AI7 TB7 R21 R109 C21 ADDRESS AI8 GND C46 2.) IT IS RECOMMENDED THAT YOU WRITE THE DESCRIPTION OF THE INPUT, AND/OR OUTPUTS YOU ARE CONNECTING TO THE CONTROLLER IN THE BOXES PROVIDED ABOVE ® USING A PERMANENT MARKER (SHARPIE) FOR FUTURE REFERENCE. AI6 AI6 GND .1uF AI2 AI8 GND ON BOARD COMMLINK CONNECT STATUS1 AI3 AI6 GND Both Jumpers OFF .1uF NORMAL OPERATION SCHEDULE OVERRIDE AI1 AI5 ON BOARD COMMLINK CONNECT AOUT2 LED BLINK CODES LED NAME 0-5V 0-10V 4-20mA THERM AI3 AOUT 3-4 Both Jumpers ON AOUT1 AOUT 1-2 AI1 1002 SW1 TB8 C14 .01uF JOB NAME FILENAME GPCXP-CommLinkSwitchSet-1A.CDR DATE: 12/27/12 PAGE 1 of 1 DRAWN BY: S. Olson DESCRIPTION: OE332-23-GPC-XP GPC-XP CommLink Setting Figure 68: OE332-23-GPCXP GPC-XP Controller On-Board CommLink Setting VCM-X Component & Systems Wiring 91 Add-On Devices GBD-X Controller - CO2 Applications Wiring Figure 69: OE332-23-GBDX GBD-X Controller Wiring CO2 Applications 92 VCM-X Component & Systems Wiring Add-On Devices GBD-X Controller - CO2 Applications Wiring (Cont’d) Figure 70: OE332-23-GBDX GBD-X Controller Wiring CO2 Applications VCM-X Component & Systems Wiring 93 Add-On Devices GBD-X Controller - Space Temp. Sensor Averaging Wiring Figure 71: OE332-23-GBDX GBD-X Controller Wiring- Space Temperature Sensor Averaging 94 VCM-X Component & Systems Wiring Add-On Devices GBD-X Controller - Space Temp. Sensor Averaging Wiring (Cont’d) Figure 72: OE332-23-GBDX GBD-X Controller Wiring- Space Temperature Sensor Averaging VCM-X Component & Systems Wiring 95 Add-On Devices GBD-X Controller Address Switch Setting Figure 73: OE332-23-GBDX GBD-X Controller Addressing 96 VCM-X Component & Systems Wiring Module Wiring & Connections Module Wiring & Connections VCM-X Component & Systems Wiring 97 Module Wiring & Connections HP1C Module Wiring When Used With The VCM-X E-BUS NOTE: ALL RELAY OUTPUTS ARE NORMALLY OPEN AND RATED FOR 24 VAC POWER ONLY - 1 AMP MAXIMUM LOAD OE370-23-HP1C One Condenser Head Pressure Module CONDENSER A ENABLE REVERSING VALVE A ENABLE HVAC UNIT CONNECTION Head Pressure Transducers RD WH BK Condenser Signal A +V SIG GND +5V www.aaon.com SIG 1 GND +V SIG GND RD WH BK +V SIG GND RD WH BK +V SIG GND +5V SIG 2 GND +5V SIG 3 GND +5V SIG 4 GND BIN 1 BIN 2 REV. VLV. ENABLE R2 R1 NOT USED R3 R2 NOT USED R4 RELAY COMMON RC One Condenser Head Pressure Module Orion No.:OE370-23-HP1C HEAD PRESSURE TRANSDUCER #1/ A2 +5V SIG 2 GND HEAD PRESSURE TRANSDUCER #2 HEAD PRESSURE TRANSDUCER #3 LED NAME COMM Rc RELAYS ANALOG AO1 Condenser Fan ECM Motor AO2 GND YELLOW BLUE +24 OUT PWM1STAT + COM R4 AO1 AO2 GND PWM1PWM1+ PWM2PWM2+ LED BLINK CODES A3 +5V SIG 3 GND R1 R2 R3 AAON No.: R74860 COND. SIGNAL NOT USED GND COND. FAN COND. FAN NOT USED NOT USED A1 +5V SIG 1 GND R1 COND. ENABLE PWM1+ BLINKS QTY. OF SENSORS INSTALLED A4 LED NAME +5V SIG 4 GND HEAD PRESSURE TRANSDUCER #4 BIN 1 BIN 2 BIN 3 COM COND. ENABLE INPUT REV. VLV. INPUT ENABLE NOT USED COMMON ALARM NO PROBLEMS 0 NO SENSORS DETECTED 1 HIGH HEAD PRESSURE DETECTED 2 LOW HEAD PRESSURE DETECTED 3 PWM2PWM2+ E-BUS Connector WattMaster Label #LB102057-A Rev.: 1J E-BUS Connector +24 VAC COM ADDRESS GND BIN 3 ALARM STAT COMM Set ADDRESS Dip Switch 4 to OFF to make reversing valve "ON to Heat / OFF to Cool” Set to ON to make reversing valve “ON to Cool / OFF to Heat. Currently showing OFF. 24 VAC GND PWR Set ADDRESS Dip Switch 2 to OFF on all communicating applications unless it is intended to be the Second Head Pressure Module on a system. If set to ON, it will not communicate. Currently showing OFF. Duty Cycle +24 Volts OPTIONS Set ADDRESS Dip Switch 1 to ON for Water Cooled or to OFF for Air Cooled. Currently showing OFF for Air Cooled. RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC RD WH BK Line Voltage WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24 VAC-to-24 VAC. Connect To Other WattMaster-Approved E-BUS Expansion Module(s) OPTIONS Dip Switch Setting Not Required When Connected To VCM-X Modular E-BUS or VCM-X WSHP E-BUS Controller 24 VAC Transformer 3 VA Minimum HSSC Cable HSSC Cable Connect To VCM-X E-BUS Controller or VCM-X WSHP E-BUS Controller Wiring For One Condenser Head Pressure Module When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME HP1C-1A.CDR DATE: 06/04/15 PAGE 1 DRAWN BY: S. Olson DESCRIPTION: AAON One Condenser Head Pressure Wiring When Used With Orion VCM-X E-BUS Controller Figure 74: OE370-23-HP1C One Condenser Head Pressure Module to VCM-X E-BUS Controller Wiring 98 VCM-X Component & Systems Wiring Module Wiring & Connections HP2C2 Controller Wiring When Used With The VCM-X E-BUS NOTE: ALL RELAY OUTPUTS ARE NORMALLY OPEN AND RATED FOR 24 VAC POWER ONLY - 1 AMP MAXIMUM LOAD CONDENSER A ENABLE REVERSING VALVE A ENABLE OE370-23-HP2C2 Two Condenser Head Pressure II Module CONDENSER B ENABLE REVERSING VALVE B ENABLE Condenser Signal A Head Pressure Transducers + +V SIG GND RD WH BK +V SIG GND R2 R4 RELAY COMMON Two Condenser Head Pressure II Module Orion No.:OE370-23-HP2C2 SIG 2 GND +5V SIG 3 GND +5V SIG 4 GND BIN 2 HEAD PRESSURE TRANSDUCER #1 A2 +5V SIG 2 GND HEAD PRESSURE TRANSDUCER #2 +5V SIG 4 GND ADDRESS BIN 1 BIN 2 BIN 3 COM Rc Condenser Signal B + RELAYS AO1 AO2 GND PWM1PWM1+ PWM2PWM2+ COM ANALOG AO1 Condenser Fan A ECM Motor AO2 GND YELLOW Duty Cycle PWM1BLINKS QTY. OF SENSORS INSTALLED B2 LED NAME LED NAME ALARM NO PROBLEMS COND. A ENABLE INPUT REV. VLV. ENABLE INPUT COND. B ENABLE INPUT COMMON WattMaster Label #LB102110-A Rev.: 1A BLUE +24 OUT STAT PWM1+ HEAD PRESSURE TRANSDUCER #4 E-BUS Connector RC HEAD PRESSURE TRANSDUCER #3 BIN 3 COM R4 LED BLINK CODES B1 +5V SIG 3 GND R3 AAON No.: V20660 COND. A SIGNAL COND. B SIGNAL GND COND. FAN A COND. FAN A COND. FAN B COND. FAN B A1 +5V SIG 1 GND R1 R2 R3 R4 COMM PWM2- 0 NO SENSORS DETECTED 1 HIGH HEAD PRESSURE DETECTED 2 LOW HEAD PRESSURE DETECTED 3 E-BUS Connector +24 Volts YELLOW BLUE +24 OUT PWM2+ Condenser Fan B ECM Motor OPTIONS Set ADDRESS Dip Switch 2 to OFF on all communicating applications unless it is intended to be the Second Head Pressure Module on a system. If set to ON, it will not communicate. Currently showing OFF. R1 R3 +5V BIN 1 Set ADDRESS Dip Switch 1 to ON for Water Cooled or to OFF for Air Cooled. Currently showing OFF for Air Cooled. R2 COND. B ENABLE GND RD WH BK REV. VLV. A ENABLE REV. VLV. B ENABLE Duty Cycle +24 Volts ALARM STAT COMM OPTIONS Dip Switch Setting Not Required When Connected To VCM-X E-BUS PWR Set ADDRESS Dip Switch 3 to ON to disable Circuit B alarms when only one Condenser is Used. Currently showing OFF. 24 VAC +V SIG GND www.aaon.com SIG 1 GND COM R1 COND. A ENABLE GND RD WH BK +5V +24 VAC +V SIG GND RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC RD WH BK Line Voltage Set ADDRESS Dip Switch 4 to OFF to make reversing valve "ON to Heat / OFF to Cool.” Set to ON to make reversing valve “ON to Cool / OFF to Heat.” Currently showing OFF. 24 VAC Transformer 3 VA Minimum Connect To Other WattMaster-Approved E-BUS Expansion Module(s) HSSC Cable HSSC Cable Connect To VCM-X E-BUS WARNING!! Observe Polarity! All boards must be wired with GND-toGND and 24 VAC-to-24 VAC. Wiring For Two Condenser Head Pressure Module When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME HP2C2-1A.CDR DATE: 06/05/15 PAGE 1 DRAWN BY: S. Olson DESCRIPTION: Two Condenser Head Pressure Module Wiring When Used With Orion VCM-X E-BUS Controller Figure 75: OE370-23-HP2C2 Two Condenser Head Pressure Module to VCM-X E-BUS Controller Wiring VCM-X Component & Systems Wiring 99 Module Wiring & Connections Full Digital Module Wiring When Used With The VCM-X E-BUS OE370-23-FD-A Full Digital Module +5V R1 SIG 1 R2 GND R3 +5V R4 SIG 2 Rc RELAYS GND ANALOG +5V AO1 SIG 3 AO2 GND GND +5V SIG 4 PWM1- GND PWM1+ BIN 1 PWM2PWM2+ BIN 2 COM OPTIONS ADDRESS WARNING!! Observe Polarity! All boards must be wired with GND-toGND and 24 VAC-to-24 VAC. Failure to observe polarity could result in damage to the boards. ALARM STAT COMM 24 VAC GND PWR Line Voltage 24 VAC Transformer 3 VA Minimum Connect To Other WattMaster-Approved E-BUS Expansion Module(s) HSSC Cable HSSC Cable Connect To VCM-X E-BUS Wiring For Full Digital Module When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME FullDigital-1A.CDR DRAWN BY: DATE: 06/05/15 PAGE 1 S. Olson DESCRIPTION: Full Digital Module Wiring When Used With Orion VCM-X E-BUS Controller Figure 76: OE370-23-FD-A Full Digital Module to VCM-X E-BUS Controller Wiring 100 VCM-X Component & Systems Wiring Module Wiring & Connections Dual Digital Wiring When Used With The VCM-X E-BUS OE370-23-DD-C Dual Digital Module +5V R1 SIG 1 R2 GND R3 +5V R4 SIG 2 Rc RELAYS GND ANALOG +5V AO1 SIG 3 AO2 GND GND +5V SIG 4 PWM1- GND PWM1+ BIN 1 PWM2PWM2+ BIN 2 COM OPTIONS ADDRESS WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24 VAC-to-24 VAC. Failure to observe polarity could result in damage to the boards. ALARM STAT COMM 24 VAC PWR GND Software versions 1.04 or above allow two modules per HVAC unit. If using two modules, set the 1st to address 1 and the 2nd to address 2. 24 VAC Transformer Connect To Other WattMaster-Approved E-BUS Expansion Module(s) HSSC Cable HSSC Cable Connect To VCM-X E-BUS Wiring For Dual Digital Module When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME DualDigital-1A.CDR DATE: 06/05/15 PAGE 1 DRAWN BY: S. Olson DESCRIPTION: Dual Digital Module Wiring When Used With Orion VCM-X E-BUS Controller Figure 77: OE370-23-DD-A Dual Digital Module to VCM-X E-BUS Controller Wiring VCM-X Component & Systems Wiring 101 Module Wiring & Connections MODGAS-X Controller Wiring When Used With The VCM-X E-BUS MODGAS-X CONTROLLER (OE377-26-00058) Connect Supply Air Temperature Sensor To AI2 & GND On Main Controller Fan Enable And Stage 1 Heat (Mod) Supply Air Temperature Sensor Low Speed Fan Mount In Supply Air Duct The SAT OPTIONS Jumper Setting Should Be Set to 1. Only One Supply Air Temperature Sensor Can Be Used Per Application. 24 VAC Power Input Terminals Max. Power Consumption 1 Gas Valve = 18 VA 2 Gas Valves = 33 VA I2C Cable Connects To 2 I C Port On VCM-X E-BUS Controller Or Expansion Module Wiring For MODGAS-X When Used With Orion VCM-X E-BUS Controller JOB NAME DATE: 06/05/15 BY: S. Olson FILENAME O-MODGASX-VCMX-Wr1.CDR DATE: 07/02/13 PAGE 1 DRAWN BY: S. Olson DESCRIPTION: AAON MODGAS-X Wiring When Used With Orion VCM-X E-BUS Controller Figure 78: OE377-26-00058 MODGAS-X Controller Single Modulating Valve - No Staging to VCM-X E-BUS Controller Wiring 102 VCM-X Component & Systems Wiring Module Wiring & Connections MODGAS-X Controller Wiring When Used With The VCM-X E-BUS MODGAS-X CONTROLLER (OE377-26-00058) Connect Supply Air Temperature Sensor To AI2 & GND On Main Controller Fan Enable and Stage 1 Heat (Mod) Mount In Supply Air Duct Low Speed Fan Stage 2 Heat (Mod) Supply Air Temperature Sensor The SAT OPTIONS Jumper Setting Should Be Set to 1. Only One Supply Air Temperature Sensor Can Be Used Per Application. 24 VAC Power Input Terminals Max. Power Consumption 1 Gas Valve = 18 VA 2 Gas Valves = 33 VA I2C Cable Connects To VCM-X Controller’s Expansion Port Wiring For MODGAS-X When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME O-MODGASX--Wr1-2.CDR DATE: 06/05/15 PAGE 2 DRAWN BY: S. Olson DESCRIPTION: AAON MODGAS-X Wiring When Used With Orion VCM-X E-BUS Controller Figure 79: OE377-26-00058 MODGAS-X Controller Two Modulating Staged Valves to VCM-X E-BUS Wiring VCM-X Component & Systems Wiring 103 Module Wiring & Connections MODGAS-XWR Controller Wiring When Used With The VCM-X E-BUS Connect Supply Air Temperature Sensor to AI2 & GND On Main Controller MODGAS-XWR CONTROLLER (OE377-26-00060) Check Your Fan Relay Wiring (RLY1) Schematic For Proper Wiring. Mount In Supply Air Duct MADE IN USA Fan Enable Supply Air Temperature Sensor RLY1 ALARM Low Speed Fan RLY2 YS102530 REV 1 WATTMASTER CONTROLS RLY3 M UP Heat Valve 1 RLY4 COMMON AUX BIN MENU HEAT EN ENTER www.aaon.com PO-IGN1 RESET IN Proof of Ignition Signal 1 (24 VAC) ANODE DOWN OPTIONS SAT AAON No.: V20780 STATUS ALARM COMM POWER AUX. (BI) HEAT ENABLE (BI) ANODE GND WattMaster No: #SW000055 Rev.: 1A +24 VAC AUX. (AI) GND Modulating Gas Valve 1 COMMON RESET INPUT (AI) SAT INPUT (AI) GND(AI) GAS VALVE 1 GND PROOF OF IGNITION 1 PO-IGN2 ANODE The SAT OPTIONS Jumper Setting Should Be Set to 1. Only One Supply Air Temperature Sensor Can Be Used Per Application. INPUT TERMINALS (TYPE) CONTACT RATING RELAY OUTPUT IS 1 AMP MAX TERMINALS @ 24 VAC FAN LOW SPEED HEAT 1 HEAT 2 GAS VALVE 1 GAS VALVE 2 AUX AIN GND OE377-26-00060 MODGAS-XWR GAS VALVE TERMINALS GND PROOF OF IGNITION 2 GAS VALVE 2 I2C CONNECT E-BUS CONNECT Modular Cable Connects To VCM-X E-BUS Controller’s Expansion Port Wiring For MODGAS-XWR When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME MODGASXWR-1A-1.CDR DATE: 06/04/15 PAGE 1 DRAWN BY: S. Olson DESCRIPTION: AAON MODGAS-XWR Wiring When Used With Orion VCM-X E-BUS Controller Figure 80: MODGAS-XWR Controller Single Modulating Valve No Staging to VCM-X E-BUS Wiring 104 VCM-X Component & Systems Wiring Module Wiring & Connections MODGAS-XWR Controller Wiring When Used With The VCM-X E-BUS Connect Supply Air Temperature Sensor to AI2 & GND On Main Controller MODGAS-XWR CONTROLLER (OE377-26-00060) Check Your Fan Relay Wiring (RLY1) Schematic For Proper Wiring. Mount In Supply Air Duct MADE IN USA Fan Enable Supply Air Temperature Sensor RLY1 ALARM Low Speed Fan RLY2 YS102530 REV 1 WATTMASTER CONTROLS RLY3 M UP Heat Valve 1 RLY4 COMMON AUX BIN MENU HEAT EN Fixed Heat Stage ENTER www.aaon.com PO-IGN1 RESET IN Proof of Ignition Signal 1 (24 VAC) ANODE DOWN OPTIONS SAT AAON No.: V20780 STATUS ALARM COMM POWER AUX. (BI) HEAT ENABLE (BI) ANODE GND WattMaster No: #SW000055 Rev.: 1A +24 VAC AUX. (AI) GND Modulating Gas Valve 1 COMMON RESET INPUT (AI) SAT INPUT (AI) GND(AI) GAS VALVE 1 GND PROOF OF IGNITION 1 GAS VALVE 1 PROOF OF IGNITION 2 GAS VALVE 2 I2C CONNECT E-BUS CONNECT PO-IGN2 ANODE The SAT OPTIONS Jumper Setting Should Be Set to 1. Only One Supply Air Temperature Sensor Can Be Used Per Application. INPUT TERMINALS (TYPE) CONTACT RATING RELAY OUTPUT IS 1 AMP MAX TERMINALS @ 24 VAC FAN LOW SPEED HEAT 1 HEAT 2 GAS VALVE 2 AUX AIN GND OE377-26-00060 MODGAS-XWR GAS VALVE TERMINALS GND Modular Cable Connects To VCM-X E-BUS Controller’s Expansion Port Wiring For MODGAS-XWR When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME MODGASXWR-1A-2.CDR DATE: 06/04/15 PAGE 2 DRAWN BY: S. Olson DESCRIPTION: AAON MODGAS-XWR Wiring When Used With Orion VCM-X E-BUS Controller Figure 81: MODGAS-XWR Controller Single Modulating Valve & 1 Fixed Stage to VCM-X E-BUS Wiring VCM-X Component & Systems Wiring 105 Module Wiring & Connections MODGAS-XWR Controller Wiring When Used With The VCM-X E-BUS Connect Supply Air Temperature Sensor to AI2 & GND On Main Controller MODGAS-XWR CONTROLLER (OE377-26-00060) Check Your Fan Relay Wiring (RLY1) Schematic For Proper Wiring. Mount In Supply Air Duct MADE IN USA Fan Enable Supply Air Temperature Sensor RLY1 ALARM Low Speed Fan RLY2 YS102530 REV 1 WATTMASTER CONTROLS RLY3 M UP Heat Valve 1 RLY4 COMMON AUX BIN MENU HEAT EN Heat Valve 2 ENTER www.aaon.com PO-IGN1 RESET IN Proof of Ignition Signal 1 (24 VAC) ANODE DOWN OPTIONS SAT AAON No.: V20780 STATUS ALARM COMM POWER AUX. (BI) HEAT ENABLE (BI) ANODE GND WattMaster No: #SW000055 Rev.: 1A +24 VAC AUX. (AI) GND Modulating Gas Valve 1 COMMON RESET INPUT (AI) SAT INPUT (AI) GND(AI) GAS VALVE 1 GND PROOF OF IGNITION 1 GAS VALVE 1 PROOF OF IGNITION 2 GAS VALVE 2 I2C CONNECT E-BUS CONNECT Proof of Ignition Signal 2 (24 VAC) PO-IGN2 ANODE The SAT OPTIONS Jumper Setting Should Be Set to 1. Only One Supply Air Temperature Sensor Can Be Used Per Application. INPUT TERMINALS (TYPE) CONTACT RATING RELAY OUTPUT IS 1 AMP MAX TERMINALS @ 24 VAC FAN LOW SPEED HEAT 1 HEAT 2 GAS VALVE 2 AUX AIN GND OE377-26-00060 MODGAS-XWR GAS VALVE TERMINALS GND Modulating Gas Valve 2 Modular Cable Connects To VCM-X E-BUS Expansion Port Wiring For MODGAS-XWR When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME MODGASXWR-1A-3.CDR DATE: 06/04/15 PAGE 3 DRAWN BY: S. Olson DESCRIPTION: AAON MODGAS-XWR Wiring When Used With Orion VCM-X E-BUS Controller Figure 82: MODGAS-XWR Controller Two Modulating Valves Staged to VCM-X E-BUS Wiring 106 VCM-X Component & Systems Wiring Module Wiring & Connections MHGRV-X Controller Wiring When Used With The VCM-X E-BUS Connect Supply Air Temperature Sensor To AI2 & GND On Main Controller Supply Air Temperature Sensor Mount In Supply Air Duct MHGRV-X CONTROLLER (OE377-26-00059) Fan C1 Compressor C2 HGR Solenoid Valve 2 Position HGR Valve (Optional) COMM Condenser Valve #1 BLK WHT RED GRN Set SAT OPTIONS Jumper Setting to Normal. BLK WHT GRN RED GND 24VAC HGR Valve #1 2 I C Cable Connects To 2 I C Port On Any Non VCB-X Controller Or Expansion Module 40 VA Transformer Minimum Line Wiring For MHGRV-X When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME O-AAON-MHGRVX-VCMX-1A.CD Notes: 1.)All Wiring To Be In Accordance With Local And National Electrical Codes and Specifications. DATE: 07/02/13 PAGE 1 DRAWN BY: S. Olson DESCRIPTION: AAON MHGRV-X Controller When Used With Orion VCM-X E-BUS Controller Figure 83: OE377-26-00059 MHGRV-X Controller to VCM-X E-BUS Controller Wiring VCM-X Component & Systems Wiring 107 Module Wiring & Connections WSHP-X2 Controller Wiring When Used With The VCM-X E-BUS OE334-26-WSHP-X2 Water Source Heat Pump X2 Module RD WH BK CIRCUIT A SUCTION PRESSURE TRANSDUCER NOTE: ALL RELAY OUTPUTS ARE NORMALLY OPEN AND RATED FOR 24 VAC POWER ONLY HVAC +V SIG 1 GND YS102374 REV 0 WATTMASTER CONTROLS ALARM MADE IN USA M +V SIG 1 GND ENTER MENU www.aaon.com DOWN www.orioncontrols.com OE334-26-WSHP-X2 WSHP-X2 MODULE +5 TO RED, PRES TO WHT & GND TO BLK DIGITAL COMRESSORS +5V NOT USED PRES PRES 1=A1, PRES 2=A2 GND PRES 3=B1, PRES 4=B2 WARNING!! Observe Polarity! All boards must be wired with GND-to-GND and 24 VAC-to-24 VAC. Failure to observe polarity could result in damage to the boards. +5 NOT USED, PRES TO P6 & GND TO P5 WATER POF BIN6 COM T1 BIN1 - COMP A1 EN BIN6 - H2O POF A BIN2 - COMP A2 EN BIN7 - H2O POF B BIN3 - COMP B1 EN COM - COMMON BIN4 - COMP B2 EN BIN5 - HEAT ENABLE T 1 - LEAVING WATER TEMP T 2 - LEAVING WATER TEMP GND - GROUND E-BUS HSSC CONNECT WattMaster Label #SW000063 Rev.: 1B AAON NO.: V48820 RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC COMP. A1 ENABLE COMP. A2 ENABLE COMP. B1 ENABLE COMP. B2 ENABLE ALARM OUTPUT RELAY COMMON AOUT1 AOUT2 AOUT3 AOUT4 R1 R2 R3 R4 R5 RC DIGITAL/VFD COMPRESSORS A1, A2, B1, B2 E-BUS HSSC CONNECT COMP A1 COMP A2 COMP B1 COMP B2 SEE NOTE BELOW NOTE: DIGITAL COMPRESSORS = 1.5-5VDC VFD COMPRESSORS = 0-10VDC AOUT1 - COMP A1 CONNECT TO C2 AOUT2 - COMP A2 CNTLR TERM. AOUT3 - COMP B1 AOUT4 - COMP B2 GND NON-DIGITAL COMPRESSORS SUCT. PR. SENSOR +5V PRES 1=A1, PRES 2=A2 PRES PRES 3=B1, PRES 4=B2 GND COMP. A1 ENABLE COMP. A2 ENABLE COMP. B1 ENABLE COMP. B2 ENABLE ALARM OUTPUT +24 VAC RD WH BK CIRCUIT B SUCTION PRESSURE TRANSDUCER R1 R2 R3 R4 R5 COMM UP GND Connect To Other WattMaster-Approved E-BUS Expansion Module(s) 24 VAC E HSSC Cable Connect To VCM-X E-BUS Controller LEAVING WATER TEMPERATURE SENSOR Wiring For WSHP-X2 When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME WSHPX2-Wr1.CDR DATE: 06/05/15 PAGE 1 DRAWN BY: S. Olson DESCRIPTION: AAON WSHP-X2 Wiring - Single Circuit When Used With Orion VCM-X E-BUS Controller Figure 84: OE334-26-WSHP-X2 WSHP-X2 Controller Single Circuit Wiring to VCM-X E-BUS Controller 108 VCM-X Component & Systems Wiring Miscellaneous Diagrams and Technical Information WSHP-X2 Controller Wiring When Used With The VCM-X E-BUS OE334-26-WSHP-X2 Water Source Heat Pump X2 Module +V SIG 1 GND CIRCUIT A2 SUCTION PRESSURE TRANSDUCER RD WH BK +V SIG 2 GND CIRCUIT B1 SUCTION PRESSURE TRANSDUCER RD WH BK +V SIG 1 GND CIRCUIT B2 SUCTION PRESSURE TRANSDUCER RD WH BK +V SIG 2 GND HVAC YS102374 REV 0 WATTMASTER CONTROLS ALARM MADE IN USA DOWN OE334-26-WSHP-X2 WSHP-X2 MODULE NON-DIGITAL COMPRESSORS SUCT. PR. SENSOR +5V PRES 1=A1, PRES 2=A2 PRES PRES 3=B1, PRES 4=B2 GND +5 TO RED, PRES TO WHT & GND TO BLK +5 NOT USED, PRES TO P6 & GND TO P5 WATER POF A WATER POF B BIN6 BIN7 COM T1 T2 ENTER MENU www.aaon.com www.orioncontrols.com DIGITAL COMRESSORS +5V NOT USED PRES PRES 1=A1, PRES 2=A2 GND PRES 3=B1, PRES 4=B2 WARNING!! Observe Polarity! All boards must be wired with GND-toGND and 24 VAC-to-24 VAC. Failure to observe polarity could result in damage to the boards. R1 R2 R3 R4 R5 COMM UP M AOUT1 COMP A1 AOUT2 COMP A2 AOUT3 COMP B1 AOUT4 COMP B2 R1 R2 R3 R4 R5 RC BIN1 - COMP A1 EN BIN6 - H2O POF A DIGITAL/VFD COMPRESSORS BIN2 - COMP A2 EN BIN7 - H2O POF B A1, A2, B1, B2 BIN3 - COMP B1 EN COM - COMMON AOUT1 - COMP A1 CONNECT TO BIN4 - COMP B2 EN C2 BIN5 - HEAT ENABLE AOUT2 - COMP A2 CNTLR TERM. T 1 - LEAVING WATER TEMP AOUT3 - COMP B1 T 2 - LEAVING WATER TEMP AOUT4 - COMP B2 GND - GROUND E-BUS HSSC CONNECT WattMaster Label #SW000063 Rev.: 1B COMP. A1 ENABLE COMP. A2 ENABLE COMP. B1 ENABLE COMP. B2 ENABLE ALARM OUTPUT AAON NO.: V48820 RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC COMP. A1 ENABLE COMP. A2 ENABLE COMP. B1 ENABLE COMP. B2 ENABLE ALARM OUTPUT RELAY COMMON GND RD WH BK E-BUS HSSC CONNECT SEE NOTE BELOW NOTE: DIGITAL COMPRESSORS = 1.5-5VDC VFD COMPRESSORS = 0-10VDC +24 VAC CIRCUIT A1 SUCTION PRESSURE TRANSDUCER NOTE: ALL RELAY OUTPUTS ARE NORMALLY OPEN AND RATED FOR 24 VAC POWER ONLY GND Connect To Other WattMaster-Approved E-BUS Expansion Module(s) 24 VAC E HSSC Cable Connect To VCM-X E-BUS LEAVING WATER TEMPERATURE FOR SYSTEM A LEAVING WATER TEMPERATURE FOR SYSTEM B Wiring For WSHP-X2 When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME WSHPX2-Wr1-2.CDR DATE: 06/05/15 PAGE 2 DRAWN BY: S. Olson DESCRIPTION: AAON WSHP-X2 Wiring - Dual Circuit When Used With Orion VCM-X E-BUS Controller Figure 85: OE334-26-WSHP-X2 WSHP-X2 Controller Dual Circuit Wiring to VCM-X E-BUS Controller VCM-X Component & Systems Wiring 109 Miscellaneous Diagrams and Technical Information PREHEAT-X Controller Wiring When Used With The VCM-X E-BUS Note: All Relay Outputs Are Normally Open And Rated For 24 VAC Power Only. 1 Amp Maximum Load. PREHEAT-X CONTROLLER (OE377-26-00061) Leaving Air 1 Temperature Sensor Mount Inside PREHEAT-X Box Wall Leaving Air 2 Temperature Sensor Mount Inside PREHEAT-X Box Wall ALARM ALARM M M BIN1 BIN2 Mount Sensor Outdoors In Shaded Protected Area & In Upright Position As Shown Emergency Shutdown OE377-26-00061 PREHEAT-X PREHEAT-X OE377-26-00061 ANALOG INPUTS ANALOG INPUTS LAT1 LAT1 0-10VRESET RESET 0-10V GND GND GND GND BINARYINPUTS INPUTS BINARY ENABLE ENABLE EMERG. SHUTDOWN EMERG. SHUTDOWN FUTURE USE FUTURE USE RS-485 COMM RS-485 COMM SHLD SHLD Heat 4 Relay AAON No.: V48510 Heat 5 Relay Heat 6 Relay ALARM CONTACT ALARM CONTACT LAT2 LAT2 OAT EAT COM HEAT HEAT 11 HEAT HEAT 22 HEAT OUTPUTS HEAT Modulating SCR (0-10 VDC) + HEAT HEAT 33 OUTPUTS HEAT 44 CONTACT RATING IS HEAT 1 AMPRATING MAX IS HEAT CONTACT HEAT 55 24 MAX VAC 1@ AMP HEAT HEAT 66 @ 24 VAC RLY COMM RLY COMM ANALOG ANALOG OUTPUTS OUTPUTS MSTP BACnet R(+) R(+) WattMaster Label E-BUS E-BUS #LB102XXX-A WattMaster Label #SCONNECT W000062 Rev.: 1A CONNECT Rev.: 1D + - Heat 3 Relay DOWN DOWN www.orioncontrols.com www.orioncontrols.com T(-) T(-) GND Heat 2 Relay ENTER ENTER E-BUS E-BUS CONNECT CONNECT – PWM SSR 0-10V MOD. SCR 0-10V MOD. SCR GND GND PWM + PWM + PWM PWM - + – GND Heat Enable Signal (24 VAC) W1 24VAC Make Splice Connections Inside Sensor Enclosure As Shown. Seal All Conduit Fittings With Silicone Sealant Heat 1 Relay MENU MENU www.aaon.com www.aaon.com GND GND AIN1 AIN2 AIN3 RST GND GND Relay Contact +24VAC VAC +24 Entering Air Temperature Sensor Reset In 0-10 VDC Alarm UP N.C. SAFETIES (BY OTHERS) NOTE: Reset In And Heat Enable Inputs Are Used In Stand-Alone Mode Only HSSC E-BUS Cable Connects To VCM-X Controller’s Expansion Port 40 VA Transformer Minimum Line Wiring For PREHEAT-X When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME PREHEATX-1A.CDR DATE: 06/10/15 PAGE 1 DRAWN BY: S. Olson DESCRIPTION: AAON PREHEAT-X Wiring When Used With Orion VCM-X E-BUS Controller Figure 86: OE377-26-00061 PREHEAT-X Controller Single Circuit Wiring to VCM-X E-BUS Controller 110 VCM-X Component & Systems Wiring Miscellaneous Diagrams and Technical Information MODGAS II Controller Wiring When Used With The VCM-X E-BUS 2 Gas Valves Can Be Connected As Shown Note: 1.) When The MODGAS II Controller Is Used With The VCM-X Controller It Must Have (1) Relay Output On The VCM-X Controller Configured For The MODGAS II Controller In Order To Function Correctly. This Relay Output Must Be Configured When Setting-up The Controller(s) Operating Parameters. See the VCM-X Controller Operator Interfaces Technical Guide For Complete Controller Programming and Configuration Information. GV2 V3 D9 V5 K3 K2 GAS VALVE V2 SER. #: VOUT GV1 GND TB4 FT V1 C13 COM CR2 LO SPD CR1 CX3 LO SPD AUX FAN CX4 ADD O F F RAM 1 2 4 8 16 32 64 128 DISCHARGE SETPOINT TB1 U4 FAN Hi Speed U3 AUX Low Speed EPROM K1 CX2 YS101818 552 PROCESSOR BOARD CX5 U2 O F F ADD R1 1 R3 J01 R1 CX1 AUX IN R9 R8 PHILIPS P1 U1 C4 U6 CX6 R7 P VR1 C7 POWER TB3 POWER 24VAC V4 D8 R25 R26 C6 R26 T R TB2 I2C IN SHLD R15 U5 PJ1 40 VA Transformer Minimum D1 RV1 YS101826PREV 1 MODULATING GAS BOARD P1 +VDC C2 WDOG C1 SAT R2 D2 HEAT EN RST IN Heat Enable Signal (24 VAC) W1 PHILIPS C2 GND C3 P STATUS C1 R1 GND RESET LIMIT 1 2 4 8 16 32 64 128 U5 R4 24VAC Line GND Modular Cable Connects To HVAC Unit Controller L1 L2 CR1-B N.C. CR1-A N.O. N.O. CR2-1 Motor SC Speed Control N.O. Induced Air Blower Caution: The Supply Air Temperature Sensor Always Connects To The VCM-X Controller And The Supply Air Temperature Is Broadcast To The MODGAS II Controller, MHGRVII And The MHGRVIII Controller From It. Wiring For MODGAS II When Used With Orion VCM-X E-BUS Controller JOB NAME 1.)24 VAC Must Be Connected So That All Ground Wires Remain Common. 2.)All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. FILENAME O-MODGASII-VCMX-Wr1.CDR DATE: 10/09/09 PAGE 1 DRAWN BY: B. Crews DESCRIPTION: AAON MODGAS II Wiring When Used With Orion VCM-X Controller Figure 87: OE377-00-00041 MODGAS II Controller to VCM-X E-BUS Controller Wiring VCM-X Component & Systems Wiring 111 Miscellaneous Diagrams and Technical Information MHGRV II Controller Wiring When Used With VCM-X E-BUS Fan C1 Compressor C2 HGR Solenoid Valve 2 Position HGR Valve (Optional) “AUX” Relay LED “VALVE” Relay LED 24 VAC “COMP” Relay LED R40 R39 STATUS U5 RESET LIMIT K4 AUX K3 K2 VALVE K1 COMP R23 CR/HG U3 C4 U4 “STATUS” LED HTG OVR CX2 U5 EPROM Chip CX5 RHT EN CX4 RAM R9 R8 D4 R13 R7 D3 R6 R5 AUX IN RST IN U2 R1 CLG OVR 1 YS101818 552 PROCESSOR BOARD GND C2 GND U1 AUX IN SETUP THERM 4-20MA 0-10V +VDC “POWER” LED CX3 CW/HW CB/HB GND C3 C1 SAT D2 TB3 X1 RAM Chip R2 RV1 COMM R CX1 R4 PU R12 T SHLD Setpoint DIP Switch (Not Used For This Application) R17 EPROM CG/HR STEP CX5 R2 Green Red White Black C15 1 2 4 8 16 32 64 128 SETPOINT SW2 AUX COM SW1 COMP VALVE FAN V4 V2 V1 1 2 4 8 16 32 64 128 O FAN ADD ADD F F SERIAL # POWER TB5 YS101894 REV 1 HOT GAS REHEAT O F F Green Red White Black Condensor Modulating HG Valve Reset Limit DIP Switch (Not Used For This Application) “FAN” Relay LED V3 Reheat Modulating HG Valve P1 C2 D1 C12 C4 C13 D1 R20 TB4 GND U2 C3 U1 CX6 D5 R3 R3 I2 C IN +24VAC D1 R19 PJ1 V5 Modular Cable Connect To HVAC Unit Controller U6 I2 C OUT D6 R11 R1 WDOG VR1 R31 D11 R18 Caution: The Supply Air Temperature Sensor Always Connects To The VCM-X E-BUS Controller And The Supply Air Temperature Is Broadcast To The MODGAS II Controller, MHGRVII, And The MHGRVIII Controller From It. GND 24VAC C8 L1 C1 L2 R38 40 VA Transformer Minimum Line Wiring For MHGRV II When Used With Orion VCM-X E-BUS Controller JOB NAME FILENAME O-AAON-MHGRVII-VCMX-1A.CD Notes: 1.)All Wiring To Be In Accordance With Local And National Electrical Codes and Specifications. DATE: 10/09/09 PAGE 1 DRAWN BY: B. Crews DESCRIPTION: AAON MHGRV II Controller When Used With Orion VCM-X Controller Figure 88: OE377-00-00042 MHGRV II Controller to VCM-X E-BUS Controller Wiring 112 VCM-X Component & Systems Wiring Miscellaneous Diagrams and Technical Information MHGRV III Controller Wiring When Used With VCM-X E-BUS Condenser Valve #1 Not Required When Only One Set Of Condenser & HGR Valves Is Used GRN RED WHT BLK Mount In Supply Air Duct HGR Valve #1 GRN RED WHT BLK Supply Air Temperature Sensor Supply Air Temperature Sensor Connects to AI2 & GND On VCM-X Controller Modular Cable Connects To VCM-X Expansion Port OMRON G5Q-1A4 DC24V THERM 4-20 0-10V CG/HR VAVLE EXP AUX IN CR/HG CW/HW CR/HR +VDC GND AUX IN REC GND RESET RHT EN COOL OVR 485 DRV HEAT OVR GND T SAT SH R LT1785 SA VDE 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE FAN 5A30VDC CHINA 10A250VAC ~ OMRON SA G5Q-1A4 DC24V VDE VALVE 5A30VDC CHINA 10A250VAC ~ COM CMP AUX 0-5V STEP STAT ADD RESET LIMIT SF000093a EPROM CHASSIS GND GND AOUT YS102138 REV 2 POWER ADD SETPOINT GND 24VAC HOT GAS REHEAT III 24VAC GND MHGRV III Controller Condenser Valve #2 GRN RED WHT BLK 40 VA Transformer Minimum HGR Valve #2 Line GRN RED WHT BLK JOB NAME FILENAME (Optional) HGR Valve Slave Board #1 Only Required When More Than One Set Of Condenser & HGR Valves Are Needed MODGASIII-1A-1.CDR DATE: 06/09/15 PAGE 1 DRAWN BY: S. Olson DESCRIPTION: AAON MODGAS III Wiring When Used With Orion VCM-X E-BUS Controller Figure 89: OE377-00-00054 MHGRV III Controller to VCM-X E-BUS Controller Wiring VCM-X Component & Systems Wiring 113 Miscellaneous Diagrams and Technical Information 114 VCM-X Component & Systems Wiring Miscellaneous Diagrams and Technical Information Miscellaneous Diagrams & Technical Information VCM-X Component & Systems Wiring 115 Miscellaneous Diagrams and Technical Information Modular Room Sensor Wiring 2.00“ 2.75“ 0.88“ YS101858 REV 0 C O O L E R 2.75“ 4.50“ 3.25“ OVR 2.50" MODULAR SENSOR W A R M E R PJ1 R2 THERM1 0.25“ R1 Wall Cut-Out Dimensions When Sensor Is To Be Mounted Without Handy Box (By Others) Room Sensor Typical Dimensions W A R M E R C O O L E R OVR OE210-02 OE211-02 Modular Room Sensor Plain W A R M E R Modular Room Sensor With Override OVR C O O L E R OE212-02 OE213-02 Modular Room Sensor With Setpoint Adjust Modular Room Sensor With Setpoint Adjust & Override Temperature Sensor Resistance/Voltage Chart Temp Resistance* Voltage Ohms @ Input* °F -10.............93333 ........4.620 -5...............80531 ........4.550 0 ...............69822 ........4.474 5 ...............60552 ........4.390 10 ..............52500 ........4.297 15 ..............45902 ........4.200 20 ..............40147 ........4.095 25 ..............35165 ........3.982 30 ..............30805 ........3.862 35 ..............27140 ........3.737 40 ..............23874 ........3.605 Temp Resistance* Voltage °F Ohms @ Input* 69 ..............11906 ........2.780 70 ..............11652 ........2.752 71 ..............11379 ........2.722 72 ..............11136 ........2.695 73 ..............10878 ........2.665 74 ..............10625 ........2.635 75 ..............10398 ........2.607 76 ..............10158 ........2.570 78 ..............9711 ..........2.520 80 ..............9302 ..........2.465 82 ..............8893 ..........2.407 Temp Resistance* Voltage °F Ohms @ Input* 45 ..............21094 ........3.470 50 ..............18655 ........3.330 52 ..............17799 ........3.275 54 ..............16956 ........3.217 56 ..............16164 ........3.160 58 ..............15385 ........3.100 60 ..............14681 ........3.042 62 ..............14014 ........2.985 64 ..............13382 ........2.927 66 ..............12758 ........2.867 68 ..............12191 ........2.810 Temp Resistance* Voltage Ohms @ Input* °F 84 ..............8514 ..........2.352 86 ..............8153 ..........2.297 88 ..............7805 ..........2.242 90 ..............7472 ..........2.187 95 ..............6716 ..........2.055 100 ............6047 ..........1.927 105 ............5453 ..........1.805 110 ............4923 ..........1.687 115 ............4449 ..........1.575 120 ............4030 ..........1.469 *Chart Notes: 1. Use the resistance column to check the thermistor sensor while disconnected from the controllers (not powered). Connect as shown below. 2. Use the voltage column to check sensors while connected to powered controllers. Read voltage with meter set on DC volts. Place the sensor leads as shown in the illustration below. If the voltage is above 5.08 VDC, then the sensor or wiring is "open." If the voltage is less than 0.05 VDC, the sensor or wiring is shorted. JOB NAME + - + - R1 R2 PJ1 FILENAME O-MODRMSENS1.CDR THERM1 YS101858 REV 0 MODULAR SENSOR DATE: 10/11/01 PAGE 1 T SHLD DRAWN BY: B. CREWS DESCRIPTION: OE210-02, OE211-02, OE212-02, OE213-02 Modular Room Sensor Figure 90: OE210-02, OE211-02, OE212-02, OE213-02 Modular Room Sensor Wiring 116 VCM-X Component & Systems Wiring Miscellaneous Diagrams and Technical Information EPROM Chip Locations PAL Chip (U10) Pin 1 RS-485 Communications Driver Chip (U14) Pin 1 EPROM Chip (U7) Pin 1 RAM Chip (U6) Pin 1 Address Switch CPU (U4) OE332-23E-VCMX-MOD - VCM-X E-BUS Controller RAM Chip (U8) Pin 1 EPROM Chip (U3) Pin 1 EXPANSION PAL D'STAT EPROM ACTUATOR 0 OE282 PROCESSOR 24 Mhz ADDRESS OFF ON REC WDOG POWER / COMM Communications Driver Chip (U10) Pin 1 93C66 EEPROM SPACE SENSOR 485 DRV 1 AIRFLOW LOW(VVT) VELOCITY PWR STAT HI(VAV) MADE IN USA WATTMASTER CONTROLS INC Address Switch OE742-31-VAVZ or OE742-31-VAVZ VAV/Zone Controller Actuator Package Warning! Use Extreme Caution When Removing Any Chips To Avoid Damaging Any Circuit Board Traces Which Are Under The Chip. Be Sure That Any Small Screwdriver Or Other Sharp Object Used To Remove The Chip Does Not Come Into Contact With The Printed Circuit Board. A Small Screwdriver May Be Inserted Between The Chip And The Socket To Aid In Removal Of The Chip. Be Very Careful Not To Insert The Screwdriver Under The Socket!! Damage To The Board Is Not Covered By Warranty. JOB NAME BY: DATE: 05/20/15 S. OLSON FILENAME O-VCMX-DRCHPREP-1B.CDR DATE: 10/09/09 PAGE 1 of 4 DRAWN BY: B. CREWS DESCRIPTION: Orion Components VCM-X Product Chip Replacement Information Figure 91: EPROM Chip Locations for VCM-X E-BUS & VAV/Zone Controller Actuator Package VCM-X Component & Systems Wiring 117 Miscellaneous Diagrams and Technical Information EPROM Chip Locations (Cont’d) ACTUATOR EXPANSION C1 JP1 R10 C3 D3 C6 R9 R8 R7 R6 R5 R4 R3 WDOG CX3 C5 CX4 C7 U3 REC SCAN P2 R16 U6 CX6 C8 R22 R18 R20 R19 R15 R14 C12 HAND HELD C10 C9 R21 P3 R23 D5 L1 U8 C13 PWR SPACE SENSOR CX8 CX7 R25 485 DRIVER R32 AUX TB2 PJ3 PJ4 U11 CX11 VR1 RV1 U10 AIN GND EPROM CX10 PAL R24 R37 R36 R35 D4 U7 AIRFLOW R33 C14 DE IN THE USA PAL Chip (U9) Pin 1 P1 U5 U4 R38 JP2:ON=VAV OFF=VVT Q2 C11 JP2 RN1 D2 D1 Q1 Q3 POWER AND COMM R1 U2 X1 C4 U9 K2 ADD SW1 CX1 SER# U1 VAVZ CONTROLLER SYS101854 REV. 3 C2 CX9 K1 PJ2 PJ1 1 2 4 8 16 32 NET EEPROM Comm Driver Chip (U8) Pin 1 EPROM Chip (U10) Pin 1 OE324 - VAV/Zone Controller P2 U1 CX1 C2 CX7 RV1 P1 R3 PROCESSOR BOARD YS101818P552 X1 C2 CX3 U3 CX4 C1 CX5 CX2 U7 C4 VREF MiniLink EPROM Chip (U6) Pin 1 Polling Device PAL Chip (U2) Pin 1 Polling Device RAM Chip (U4) Pin 1 C1 Polling Device EPROM Chip (U3) Pin 1 X1 R4 U4 C3 CX6 U5 LED 1 D1 CX10 EPROM LED 2 U6 U10 YS101900 MINILINK POLLING DEVICE REV. 1 C3 CX1 U2 EPROM CX2 RAM R2 R24 C13 C7 UL LABEL C8 U11 WDOG R R CX11 R1 U1 CX6 U6 POWER C12 RN2 U14 P5 1 2 4 8 16 32 X2 R28 R29 R30 ADD R SHLD T C10 RN3 SERIAL # NETWORK LOOP TB4 SHLD LD4 P3 CX14 NETWORK DRIVER U13 CX13 T AIN 2 GND TB3 TB2 C11 LD5 LOCAL LOOP LD6 R35 D5 AIN 1 +24VDC OFF=0-5V GND 24VAC V1 TB1 0-10V 4-20mA THERM R R31 VR2 AIN2 0-10V 4-20mA THERM LOOP DRIVER U15 R27 AIN1 CX15 C9 D4 PROC. DRIVER SW1 P4 Processor Comm Driver Chip (U15) Pin 1 Local Loop Comm Driver Chip (U13) Pin 1 Network Loop Comm Driver Chip (U14) Pin 1 OE364-22 - MiniLink Polling Device Warning! Use Extreme Caution When Removing Any Chips To Avoid Damaging Any Circuit Board Traces Which Are Under The Chip. Be Sure That Any Small Screwdriver Or Other Sharp Object Used To Remove The Chip Does Not Come Into Contact With The Printed Circuit Board. A Small Screwdriver May Be Inserted Between The Chip And The Socket To Aid In Removal Of The Chip. Be Very Careful Not To Insert The Screwdriver Under The Socket!! Damage To The Board Is Not Covered By Warranty. JOB NAME BY: DATE: 05/20/15 S. OLSON FILENAME O-VCMX-DRCHPREP-1B.CDR DATE: 10/09/09 PAGE 2 of 4 DRAWN BY: B. CREWS DESCRIPTION: Orion Components VCM-X Product Chip Replacement Information Figure 92: EPROM Chip Locations for VAV/Zone Controller & MiniLink Polling Device 118 VCM-X Component & Systems Wiring Miscellaneous Diagrams and Technical Information EPROM Chip Locations (Cont’d) EPROM Chip (U3) Pin 1 CX3 C21 U3 CX1 CX2 U2 RN1 1 PAL Chip (U4) Pin 1 D1 RAM Chip (U2) Pin 1 Comm Driver Chip (U5) Pin 1 U1 CX4 RLY1 U4 V1 D2 TB1 COMM V2 T SHLD RLY2 V3 COM1-3 D3 RCX5 U5 PAL RS-485 COMM RLY3 RN3 (1 MEG) YS101816 REV. 2 U6 D4 LD8 LED1 TUC-5R PLUS HH RN2 1 R4 R5 C1 +VREF C2 U8 CX10 R6 L1 D14 SC1 U13 R15 U12 CX14 C14 R19 C16 U14 CX13 TB4 C15 D19 GND D16 R22 C19 C18 D18 PJ3 PJ2 EXPANSION 24VAC 7824CT CX15 M C20 R26 D17 R24 R25 R27 U15 V6 D15 PJ1 PRESSURE SENSOR U11 D12 R13 C13 C12 AOUT2 AIN7 GND C17 C9 CX12 JP1 R11 X2 C11 0-5 VDC D11 PU7 0-1 VDC GND C10 GND AOUT1 C7 U10 SW1 D9 PU5 AIN5 NE5090NPB3192 0PS CX8 U9 R10 D7 PU3 RN4 1 2 4 8 16 32 TOKEN NETWORK PU1 D6 PU2 D8 PU4 1 ADD RN5 AIN1 AIN2 AIN3 AIN4 R7 ADDRESS +VDC D10 INPUTS RLY5 V5 C3 R28 V4 X1 PHILIPS EWDOG RV1 VREF ADJ TB2 D5 CX6 5.11V TEST POINT U7 D13 R1 COM4-5 RLY4 P1 MC34064A 9936 LD9 LED2 TB3 R1 R2 R3 1 EPROM RAM COMM LD7 PWR POWER LD6 T'STAT VR1 VR2 OE330 - GPC Plus & GBD Controller Warning! C4 C3 C21 PU C5 C6 R31 D5 ANALOG INPUTS +V PU +V T.P. 5.11V R14 PU 4 PU 5 C7 VR1 R16 C8 C34 R65 R37 R38 R39 3 R15 U15 C25 6 7 R17 PU R18 C16 8 R19 R20 PU G C9 P2 D15 C10 D13 U9 C23 CX17 U17 R62 L1 R32 D11 C17 R13 G U13 V1 TB1 R21 PU R22 K1 REV. 4 V2 R51 D26 R48 ANALOG OUTPUTS THERM 8 X1 K2 TB6 CX1 C19 EPROM G U10 U11 V3 R52 D27 RAM TB2 EXP K3 TB7 BUSS U1 OUT3 R53 D28 V4 OUT4 K4 TB8 R23 R64 R1 32K 8K U2 CX10 C20 K5 TB9 JO3 R54 D29 V5 1 C1 R6 CX6 CX2 K6 TB10 CX12 U12 V6 R55 D30 U6 PAL P1 RN2 R29 D17 D18 D19 D20 D21 D22 D23 D24 OUT6 R30 Q1 JOB NAME SH U3 CB A JO2 CX3 1 2 4 8 16 A B C EPROMChip (U10) Pin 1 R R26 U7 C15 ADD SW1 R57 D32 RAM Chip (U11) Pin 1 T R28 K7 TB11 OUT7 COMM R27 TERM C11 C12 C13 C14 R56 D31 V7 OUT7 RN1 R25 OUT5 OUT6 Be Very Careful Not To Insert The Screwdriver Under The Socket!! Damage To The Board Is Not Covered By Warranty. R24 OUT4 OUT5 A Small Screwdriver May Be Inserted Between The Chip And The Socket To Aid In Removal Of The Chip. A1 A2 C18 OUT2 YS101560 TB5 JO1 CX13 Use Extreme Caution When Removing Any Chips To Avoid Damaging Any Circuit Board Traces Which Are Under The Chip. Be Sure That Any Small Screwdriver Or Other Sharp Object Used To Remove The Chip Does Not Come Into Contact With The Printed Circuit Board. 1 2 Q5 C22 + GND SIG +5V PRESSURE SENSOR JACK R33 PU R9 R10 R11 R12 D9 5.11V ADJ OUT1 OUT3 R8 D3 D7 R49 R50 LED DISPLAY R7 Q4 BATT R43 EWDOG + JO4 X2 C24 REC OUT2 U5 CX5 U5 JO5 U16 C29 C30 R59 C33 Q3 D34 R60 OUT1 C21 Q2 + WDOG CX14 SC1 R58 P3 GND PWR R61 R47 R34 R35 R36 C31 C28 P3 24V TB4 PJ1 D1 R40 D33 R44 R45 R46 U14 R41 R42 C32 D25 V8 C27 R63 C26 VR2 VR3 SERIAL # C2 TB3 PAL Chip (U6) Pin 1 Comm Driver Chip (U3) Pin 1 OE310 - GPC-17 Controller & Lighting Controller BY: DATE: 05/20/15 S. OLSON FILENAME O-VCMX-DRCHPREP-1B.CDR DRAWN BY: DATE: 10/09/09 PAGE 3 of 4 B. CREWS DESCRIPTION: Orion Components VCM-X Product Chip Replacement Information Figure 93: EPROM Chip Locations for GPC Plus, GBD, and GPC-17 Controller VCM-X Component & Systems Wiring 119 Miscellaneous Diagrams and Technical Information Chip Installation Procedures Gently Rock Chip Side To Side And Then Lift Straight Up To Remove Chip From Chip Socket. WARNING! Be sure the chip you have selected to replace is a socketed chip. Not all driver chips on the boards are field replaceable. Only socketed chips may be removed and replaced in the field. All other chips that are not socketed will require sending the board to the WattMaster factory for repair. If you try to remove a chip that is not socketed, it will destroy the circuit board. Once you have determined that the chip needing replacement is indeed a socketed chip, please proceed in the following manner: I.C. Puller Remove the communications loop connector and then the 24VAC power connector on the controller before attempting to change any components. DAMAGE will occur if components are removed or installed with power applied. Chip Chip Socket If you are unsure how to safely remove the chip or have questions about correct pin placement, please consult the factory before proceeding. Using I.C. Puller To Remove Socketed Chip Printed Circuit Board Damage to the board caused by failure to correctly remove or install the chip is not covered by the WattMaster warranty. Use extreme care to avoid inserting the screwdriver or I.C. Puller under the socket. You must insert the tip of the screwdriver or ends of the I.C. Puller between the body of the chip and the chip socket. Gently Lift The Chip On One End And Rock The Chip Back And Forth With Screwdriver As Shown.Repeat This Process On The Other End Of The Chip. Alternate This Process On Both Ends Of The Chip Until The Chip Is Free From The Chip Socket. Small Flathead Screwdriver Each chip MUST be installed with Pin 1 in the correct location. Installing the chip “backwards” will in most cases destroy the device when power is reapplied. Direction Of Pull Chip Chip Socket Printed Circuit Board Using Screwdriver To Remove Socketed Chip Pin 1 can be located by looking for the notch in the end of the chip. Pin 1 on "some" chips is identified with a dot. Be certain that ALL pins are lined up in the socket before pressing the chip in. Failure to properly line up the pins will result in damage to the chip. This is a VERY common error - BE CAREFUL. Only after confirming that the chip has been correctly installed with Pin 1 in the proper position and that the pins are lined up and none are bent or out of the socket, should communication or power wiring be reconnected to the board. To prevent possible damage, always reconnect the power wiring first and then the communication wiring. Notch Chip Dot Pin1 Chip Socket Printed Circuit Board End View Of Socketed Chip Assembly Top View Of Socketed Chip Assembly Dot Socket JOB NAME Pin 1 DATE: 05/20/15 Printed Circuit Board Typical RS-485 Communications Driver Chip Detail BY: S. OLSON FILENAME DATE: 10/09/09 PAGE 4 of 4 DRAWN BY: B. CREWS DESCRIPTION: Orion Components VCM-X Product Chip Replacement Information Figure 94: EPROM Chip Installation Instructions 120 VCM-X Component & Systems Wiring Miscellaneous Diagrams and Technical Information SD Memory Card Update Updating The SD Memory Card 6. Once you unzip the file, you will see a window similar to the one below. 7. Press <CTRL> <A> to highlight the folders in the window—App, Manuals & Scr. Press <CTRL> <C> to copy the folders. 8. Paste the folders into the SD memory card drive’s window by pressing <CTRL> <V>. 9. Remove the SD Memory Card from your computer and reinsert it in the Modular Hand Held Service Tool or Modular System Manager. You may need to update the SD memory card from time to time, either for a new release or to add data for another Controller. Follow the instructions below to download the update file from our tech support webpage: 1. Insert the SD memory card in your computer’s SD drive and open the drive’s window. 2. Open your browser and type in the address: http://wattmaster.com/techsupport. 3. On the Tech Support webpage, locate the file Modular_HH_Screens.zip and double-click on it. 4. Click <Save File> when asked to save or open the file and then click <OK>. This option will save the file to the “Downloads” folder on your PC. 5. Open the “Downloads” folder in Windows Explorer. You will find a folder labeled, “Modular_HH_Screens. zip” Right-click on the folder and choose “Extract All” from the options list. NOTE: Any compression software can be used to extract the zip folder’s contents, for example, Winzip. VCM-X Component & Systems Wiring 121 Miscellaneous Diagrams and Technical Information Updating E-BUS Module Software Updating Controller & E-BUS Module Software Using the Modular Service Tool SD E-BUS Modules 1. To update the software for various WattMaster E-BUS modules, follow these simple steps. 1. Enter Board Address 0 Update your SD memory card with the new software file for the controller or module you need to update. Follow the steps on page 121 for Updating the SD memory card. 2. Connect the Modular Service Tool to the device you wish to update using the mini DIN communication cable or EBC E-BUS cable provided. 3. Power up the controller or E-BUS module you wish to update. 4. Apply power to the Modular Service Tool SD and press the <ON> button. 5. After initialization of the Modular Service Tool SD, press <NEXT> at the first Setup Screen and <4> at the second Setup Screen shown below. 1) Set Time & Date 2) Communications NEXT) More Options ESC) Exit Menu Esc) Exit Menu 2. 3 7. 4. The screen will display the following messages: “Resetting Unit” “Load Sys Info” 5. If communications are successful, the screen will display, the name of the HEX file on the top line, “Flash Memory Erased” on the second line, and the progress percentage on the third line. NOTE: If communications are not successful, the screen will display, “Press Any Key to Continue. Cannot Load Sys Info.” Make sure you have the right address and the right software version on your SD card. If these two items are correct and you still experience a problem, contact Technical Support. Follow the instructions for WattMaster E-BUS Modules. 6. 122 The Software Version Screen will appear as shown below. Enter <0> for the latest software version or enter the number of an older version if given to you by Technical Support. Then press <ENTER>. Software Version Enter 0 for Latest 0 Esc) Exit Menu The Update Software Screen will appear as shown below: Select Communication 1) WattMaster Comm 2) E-BUS Module ESC) Exit Menu Enter the address of the E-BUS module you are updating and then press <ENTER>. The following is the list of Module addresses: WSHP-X2 - address 17 MHGRV-X - address 132 MODGAS-X - address 138 PREHEAT-X - address 157 RSM #1 - address 152 RSM #2 - address 153 RSM #3 - address 154 RSM #4 - address 155 3) Energy Saving 4) Update Software NEXT) More Options ESC) Exit Menu 6. Press <2> to update an E-BUS Module. The following screen will appear: When updating is complete, the screen will display, “Finish Download.” VCM-X Component & Systems Wiring Miscellaneous Diagrams and Technical Information Temperature & Humidity Sensor Voltage-Resistance Table Sensor Checks The following sensor voltage and resistance tables are provided to aid in checking sensors that appear to be operating incorrectly. Many system operating problems can be traced to incorrect sensor wiring. Be sure all sensors are wired per the wiring diagrams in this manual. If the sensors still do not appear to be operating or reading correctly, check voltage and/or resistance to confirm that the sensor is operating correctly per the tables. Please follow the notes and instructions below each chart when checking sensors. Temperature – Resistance – Voltage For Type III 10 K Ohm Thermistor Sensors Temp (°F) Resistance (Ohms) Voltage @ Input (VDC) Temp (°F) Resistance (Ohms) Voltage @ Input (VDC) Temp (°F) Resistance (Ohms) Voltage @ Input (VDC) -10 93333 4.620 60 14681 3.042 86 8153 2.297 -5 80531 4.550 62 14014 2.985 88 7805 2.242 0 69822 4.474 64 13382 2.927 90 7472 2.187 5 60552 4.390 66 12758 2.867 95 6716 2.055 10 52500 4.297 68 12191 2.810 100 6047 1.927 15 45902 4.200 69 11906 2.780 105 5453 1.805 20 40147 4.095 70 11652 2.752 110 4923 1.687 25 35165 3.982 71 11379 2.722 115 4449 1.575 30 30805 3.862 72 11136 2.695 120 4030 1.469 35 27140 3.737 73 10878 2.665 125 3656 1.369 40 23874 3.605 74 10625 2.635 130 3317 1.274 45 21094 3.470 75 10398 2.607 135 3015 1.185 50 18655 3.330 76 10158 2.577 140 2743 1.101 52 17799 3.275 78 9711 2.520 145 2502 1.024 54 16956 3.217 80 9302 2.465 150 2288 0.952 56 16164 3.160 82 8893 2.407 58 15385 3.100 84 8514 2.352 Thermistor Sensor Testing Instructions Use the resistance column to check the thermistor sensor while disconnected from the controllers (not powered). Use the voltage column to check sensors while connected to powered controllers. Read voltage with meter set on DC volts. Place the “-”(minus) lead on GND terminal and the “+”(plus) lead on the sensor input terminal being investigated. If the voltage is above 5.08 VDC, then the sensor or wiring is “open.” If the voltage is less than 0.05 VDC, the sensor or wiring is shorted. VCM-X Component & Systems Wiring 123 Miscellaneous Diagrams and Technical Information Temperature & Humidity Sensor Voltage-Resistance Table OE265-11, 13 & 14 Relative Humidity Transmitters – Humidity vs. Voltage For 0-5 VDC Sensors Humidity Percentage (RH) Voltage @ Input (VDC) Humidity Percentage (RH) Voltage @ Input (VDC) Humidity Percentage (RH) Voltage @ Input (VDC) Humidity Percentage (RH) Voltage @ Input (VDC) 0% 0.00 26% 1.30 52% 2.60 78% 3.90 2% 0.10 28% 1.40 54% 2.70 80% 4.00 4% 0.20 30% 1.50 56% 2.80 82% 4.10 6% 0.30 32% 1.60 58% 2.90 84% 4.20 8% 0.40 34% 1.70 60% 3.00 86% 4.30 10% 0.50 36% 1.80 62% 3.10 88% 4.40 12% 0.60 38% 1.90 64% 3.20 90% 4.50 14% 0.70 40% 2.00 66% 3.30 92% 4.60 16% 0.80 42% 2.10 68% 3.40 94% 4.70 18% 0.90 44% 2.20 70% 3.50 96% 4.80 20% 1.00 46% 2.30 72% 3.60 98% 4.90 22% 1.10 48% 2.40 74% 3.70 100% 5.00 24% 1.20 50% 2.50 76% 3.80 OE265-11, -13, and -14 Relative Humidity Sensor Testing Instructions: Use the voltage column to check the Humidity Sensor while connected to a powered expansion board. Read voltage with meter set on DC volts. Place the “-”(minus) lead on terminal labeled GND and the “+” lead on terminal AIN4 on the Analog Input/Output Expansion Board. 124 VCM-X Component & Systems Wiring Miscellaneous Diagrams and Technical Information Pressure Sensors Voltage-Resistance Tables OE271 Duct Static Pressure Sensor This sensor is used to sense duct static pressure for the Orion system controllers. The OE271 sensor is a 0-5” W.C. pressure range, 0-5 VDC voltage range sensor. Use the table and testing information below to check for proper sensor operation. OE258-01 Building Pressure Sensor This sensor is used to sense building pressure for the Orion system controllers. The OE258-01 sensor is a -0.25” to +0.25” W.C. pressure range, 0-5 VDC voltage range sensor. Use the table and testing information below to check for proper sensor operation. OE271 Duct Static Pressure Sensor Pressure @ Sensor (“ W.C.) Voltage @ Input (VDC) Pressure @ Sensor (“ W.C.) OE258 Building Pressure Sensor Voltage @ Input (VDC) Pressure @ Sensor (“ W.C.) Voltage @ Input (VDC) Pressure @ Sensor (“ W.C.) Voltage @ Input (VDC) 0.00 0.25 2.60 2.33 -0.25 0.00 0.01 2.60 0.10 0.33 2.70 2.41 -0.24 0.10 0.02 2.70 0.20 0.41 2.80 2.49 -0.23 0.20 0.03 2.80 0.30 0.49 2.90 2.57 -0.22 0.30 0.04 2.90 0.40 0.57 3.00 2.65 -0.21 0.40 0.05 3.00 0.50 0.65 3.10 2.73 -0.20 0.50 0.06 3.10 0.60 0.73 3.20 2.81 -0.19 0.60 0.07 3.20 0.70 0.08 3.30 0.70 0.81 3.30 2.89 -0.18 0.80 0.89 3.40 2.97 -0.17 0.80 0.09 3.40 0.90 0.10 3.50 0.90 0.97 3.50 3.05 -0.16 1.00 1.05 3.60 3.13 -0.15 1.00 0.11 3.60 1.10 1.13 3.70 3.21 -0.14 1.10 0.12 3.70 1.20 0.13 3.80 1.20 1.21 3.80 3.29 -0.13 1.30 1.29 3.90 3.37 -0.12 1.30 0.14 3.90 1.40 0.15 4.00 1.40 1.37 4.00 3.45 -0.11 1.50 1.45 4.10 3.53 -0.10 1.50 0.16 4.10 1.60 0.17 4.20 1.60 1.53 4.20 3.61 -0.09 1.70 1.61 4.30 3.69 -0.08 1.70 0.18 4.30 1.80 1.69 4.40 3.77 -0.07 1.80 0.19 4.40 -0.06 1.90 0.20 4.50 -0.05 2.00 0.21 4.60 -0.04 2.10 0.22 4.70 -0.03 2.20 0.23 4.80 -0.02 2.30 0.24 4.90 -0.01 2.40 0.25 5.00 0.00 2.50 1.90 1.77 4.50 3.85 2.00 1.85 4.60 3.93 2.10 1.93 4.70 4.01 2.20 2.01 4.80 4.09 2.30 2.09 4.90 4.17 2.40 2.17 5.00 4.25 2.50 2.25 OE271 Pressure Sensor Testing Instructions Use the voltage column to check the Duct Static Pressure Sensor while connected to powered controllers. Read voltage with meter set on DC volts. Place the “-” (minus) lead on the GND terminal and the “+” (plus) lead on the 0-5 pin terminal on (TP) with the jumper removed. Be sure to replace the jumper after checking. VCM-X Component & Systems Wiring OE258-01 Building Pressure Sensor Testing Instructions Use the voltage column to check the Building Static Pressure Sensor while connected to a powered expansion board. Read voltage with meter set on DC volts. Place the “-”(minus) lead on terminal labeled GND and the “+” lead on terminal AIN4 on the Analog Input/Output Expansion Board. 125 Miscellaneous Diagrams and Technical Information OE275-01 Suction Pressure Transducer Testing See the OE275-01 Suction Pressure Transducer, Pressure, Temperature, and Voltage Chart for R22 and R410A Refrigerant testing (Tables 8 and 9). The charts show a temperature range from 20°F to 80°F. For troubleshooting purposes, the DC Voltage readings are also listed with their corresponding temperatures and pressures. Signal DC Volts Temperature °F Pressure PSI Signal DC Volts Use the voltage column to check the Suction Pressure Transducer while connected to the VCM-X Expansion Module. The VCM-X and the VCM-X Expansion Module must be powered for this test. Read voltage with a meter set on DC volts. Place the positive lead from the meter on the PR OUT terminal located on the VCM-X Expansion Module terminal block. Place the negative lead from the meter on the ground (GND) terminal located adjacent to the PR OUT terminal on the VCM-X Expansion Module terminal block. Use a refrigerant gauge set and/or an accurate electronic thermometer to measure the temperature or suction line pressure near where the Suction Pressure Transducer is connected to the suction line. Measure the Voltage at the terminals PR OUT and GND terminals and compare it to the appropriate chart depending on the refrigerant you are using. If the temperature/voltage or pressure/voltage readings do not align closely with the chart, your Suction Pressure Transducer is probably defective and will need to be replaced. Pressure PSI The Evaporator Coil Temperature is calculated by converting the Suction Pressure to Temperature. The Suction Pressure is obtained by using the OE275-01 Suction Pressure Transducer, which is connected into the Suction Line of the Compressor. OE275-01 Suction Pressure Transducer Coil Pressure – Temperature – Voltage Chart for R410A Refrigerant Temperature °F OE275-01 Suction Pressure Transducer Testing for R22 and R410A Refrigerant 21.19 80.94 1.8 59.03 168.10 3.2 24.49 87.16 1.9 61.17 174.32 3.3 27.80 93.39 2.0 63.19 180.55 3.4 30.99 99.62 2.1 65.21 186.78 3.5 33.89 105.84 2.2 67.23 193.00 3.6 36.80 112.07 2.3 69.24 199.23 3.7 39.71 118.29 2.4 71.15 205.46 3.8 42.30 124.52 2.5 72.95 211.68 3.9 44.85 130.75 2.6 74.76 217.91 4.0 47.39 136.97 2.7 76.57 224.14 4.1 49.94 143.2 2.8 78.37 230.36 4.2 52.23 149.42 2.9 80.18 236.59 4.3 54.50 155.65 3.0 56.76 161.88 3.1 Signal DC Volts Pressure PSI Temperature °F Signal DC Volts Pressure PSI Temperature °F OE275-01 Suction Pressure Transducer Coil Pressure Temperature – Voltage Chart for R22 Refrigerant 20.00 31.13 1.0 55.32 93.39 20.00 37.36 1.1 58.86 99.62 2.1 20.46 43.58 1.2 62.13 105.84 2.2 25.71 49.80 1.3 65.27 112.07 2.3 30.84 56.03 1.4 68.42 118.29 2.4 35.41 62.26 1.5 71.39 124.52 2.5 39.98 68.49 1.6 75.20 130.75 2.6 44.00 74.71 1.7 77.00 136.97 2.7 48.00 80.94 1.8 79.80 143.20 2.8 51.78 87.16 1.9 80.00 149.42 2.9 126 2.0 VCM-X Component & Systems Wiring Miscellaneous Diagrams and Technical Information VCM-X Component & Systems Wiring 127 Form: OR-VCMXWIRE-TGD-01B Printed in the USA June 2015 All rights reserved. Copyright 2015 WattMaster Controls Inc. 8500 NW River Park Drive Parkville, MO 64152 Phone: 866-918-1100 www.orioncontrols.com Fax (816) 505-1101 ">
/
பதிவிறக்கு
ஒரு நட்பு நினைவூட்டல். நீங்கள் ஆவணத்தை இங்கே பார்க்கலாம். ஆனால் மிக முக்கியமாக, எங்கள் AI ஏற்கனவே அதைப் படித்துவிட்டது. இது சிக்கலான விஷயங்களை எளிய சொற்களில் விளக்கலாம், உங்கள் கேள்விகளுக்கு எந்த மொழியிலும் பதிலளிக்கலாம், மேலும் மிக நீளமான அல்லது சிக்கலான ஆவணங்களை விரைவாக செல்லவும் உதவும்.
விளம்பரம்